{"lab":{"_id":"69ad52a3de79e566650fb111","accr_number":"AB 087","country":"PL","accr_body":"PCA","address":"ul. Mory 8, 01-330 Warszawa, LABORATORIUM BADAŃ KOTŁÓW I URZĄDZEŃ GRZEWCZYCH, ul. Dostawcza 1, 93-231 Łódź","categories":["petro","water","environment"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":491,"name":"INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_087.pdf"],"scope_summary":"","search_text":"instytut energetyki – państwowy instytut badawczy ul. mory 8, 01-330 warszawa, laboratorium badań kotłów i urządzeń grzewczych, ul. dostawcza 1, 93-231 łódź water petro other metrology environment pharma electronics construction","status":"active","updated_at":"2026-03-08T14:50:10.435Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:38:31.570Z","parse_date":"2026-08-13T07:38:31.570Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://itc.edu.pl/kontakt/","fields_of_testing":[{"codes":"N/5; N/13","pl":"Badania właściwości fizycznych kotłów i urządzeń grzewczych, maszyn i urządzeń","en":"Tests of physical properties of boilers and heating devices, machinery and devices"}],"issue":{"no":"29","date":"15.06.2026"},"map_coord":[51.768732,19.456991],"map_geo":"nominatim-city","lab_locations":[{"name":"LABORATORIUM BADAŃ KOTŁÓW I URZĄDZEŃ GRZEWCZYCH","address":"ul. Dostawcza 1","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/0f0d292b3f04fc767e78812a930935e8/AB%20087.pdf","has_en":true,"category_counts":{"petro":461,"water":32,"other":26,"environment":15,"construction":1},"category_scores":{"petro":397.24,"water":1.91,"other":1.26,"environment":0.42,"construction":0},"has_zh":true},"methods":[{"_id":"6a7d7477ec6a53014a487746","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"","norm_bases":[],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE PARAMETRY WODY: KOTLY GRZEWCZE NA PALIWA STALE PARAMETRY WODY:","categories":["water","petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"水参数："},{"_id":"6a7d7477ec6a53014a487747","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(0 - 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 - 100) °C","reference":"PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2 | PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3 | PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3 | PN-M-34452:1999 p. 4.3.6","norm_bases":["PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2","PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3","PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3","PN-M-34452:1999 p. 4.3.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE temperatura (0 - 100) °C PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2 | PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3 | PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3 | PN-M-34452:1999 p. 4.3.6 KOTLY GRZEWCZE NA PALIWA STALE temperatura (0 - 100) °C PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2 | PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3 | PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3 | PN-M-34452:1999 p. 4.3.6","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(0 - 100) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2 | PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3 | PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3 | PN-M-34452:1999 p. 4.3.6","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2 | PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3 | PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3 | PN-M-34452:1999 p. 4.3.6","parameters_zh":[{"name":"温度","range":"(0 - 100) °C"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487748","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"ciśnienie","range":"(0 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0 - 0,6) MPa","reference":"PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 5.3.7","norm_bases":["PN-EN 303-5:2012 p. 5.2","PN-EN 303-5:2021-09 p. 5.2","PN-EN 303-5+A1:2023-05 p. 5.2","PN-M-34452:1999 p. 5.3.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE ciśnienie (0 - 0,6) MPa PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 5.3.7 KOTLY GRZEWCZE NA PALIWA STALE cisnienie (0 - 0,6) MPa PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 5.3.7","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(0 - 0,6) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 5.3.7","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 5.3.7","parameters_zh":[{"name":"压力","range":"(0 - 0,6) MPa"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487749","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strumień masy","range":"(0 - 80000) kg/h"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstrumień masy (0 - 80000) kg/h\n(z obliczeń)","reference":"PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 4.3.2","norm_bases":["PN-EN 303-5:2012 p. 5.2","PN-EN 303-5:2021-09 p. 5.2","PN-EN 303-5+A1:2023-05 p. 5.2","PN-M-34452:1999 p. 4.3.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE Zakres:\nstrumień masy (0 - 80000) kg/h\n(z obliczeń) PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 4.3.2 KOTLY GRZEWCZE NA PALIWA STALE Zakres:\nstrumien masy (0 - 80000) kg/h\n(z obliczen) PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 4.3.2","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"mass flow rate","range":"(0 - 80000) kg/h"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC mass flow rate (calculated) PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 4.3.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"质量流量","range":"(0 - 80000) kg/h"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 质量流量 （计算得出） PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 4.3.2","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48774a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 80) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 80) m3/h","reference":"PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2","norm_bases":["PN-EN 303-5:2012 p. 5.2","PN-EN 303-5:2021-09 p. 5.2","PN-EN 303-5+A1:2023-05 p. 5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE strumień objętości (0 - 80) m3/h PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 KOTLY GRZEWCZE NA PALIWA STALE strumien objetosci (0 - 80) m3/h PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 80) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"体积流量","range":"(0 - 80) m3/h"}]},{"_id":"6a7d7477ec6a53014a48774b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2","norm_bases":["PN-EN 303-5:2012 p. 5.2","PN-EN 303-5:2021-09 p. 5.2","PN-EN 303-5+A1:2023-05 p. 5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE PARAMETRY PALIWA: PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 KOTLY GRZEWCZE NA PALIWA STALE PARAMETRY PALIWA: PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 燃料参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"燃料参数："},{"_id":"6a7d7477ec6a53014a48774c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość wilgoci w drewnie","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE zawartość wilgoci w drewnie Procedura nr LGP/42/B wyd. 4 KOTLY GRZEWCZE NA PALIWA STALE zawartosc wilgoci w drewnie Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood Procedura nr LGP/42/B wyd. 4","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 Procedura nr LGP/42/B wyd. 4","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"木材含水率"}]},{"_id":"6a7d7477ec6a53014a48774d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strumień masy","range":"(0 - 1000) kg/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy (0 - 1000) kg/h","reference":"PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4 | PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4 | PN-M-34452:1999 p. 4.3.3","norm_bases":["PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4","PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4","PN-M-34452:1999 p. 4.3.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE strumień masy (0 - 1000) kg/h PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4 | PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4 | PN-M-34452:1999 p. 4.3.3 KOTLY GRZEWCZE NA PALIWA STALE strumien masy (0 - 1000) kg/h PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4 | PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4 | PN-M-34452:1999 p. 4.3.3","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"mass flow rate","range":"(0 - 1000) kg/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC mass flow rate PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4 | PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4 | PN-M-34452:1999 p. 4.3.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 质量流量 PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4 | PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4 | PN-M-34452:1999 p. 4.3.3","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"质量流量","range":"(0 - 1000) kg/h"}]},{"_id":"6a7d7477ec6a53014a48774e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"wartość opałowa","range":"(10 - 32) MJ/kg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE Zakres:\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń) Procedura nr LGP/42/B wyd. 4 KOTLY GRZEWCZE NA PALIWA STALE Zakres:\nwartosc opalowa (10 - 32) MJ/kg\n(z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"net calorific value","range":"(10 - 32) MJ/kg"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC net calorific value (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"低位发热量","range":"(10 - 32) MJ/kg"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 低位发热量 （计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48774f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"ODPADY PALENISKOWE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"ODPADY PALENISKOWE:","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE ODPADY PALENISKOWE: Procedura nr LGP/42/B wyd. 4 KOTLY GRZEWCZE NA PALIWA STALE ODPADY PALENISKOWE: Procedura nr LGP/42/B wyd. 4","categories":["environment","petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FURNACE WASTE:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS FURNACE WASTE: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Procedura nr LGP/42/B wyd. 4","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC Procedura nr LGP/42/B wyd. 4","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487750","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strumień masy popiołu","range":"(0 - 300) kg/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy popiołu (0 - 300) kg/h","reference":"PN-M-34452:1999 p. 4.3.3","norm_bases":["PN-M-34452:1999 p. 4.3.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE strumień masy popiołu (0 - 300) kg/h PN-M-34452:1999 p. 4.3.3 KOTLY GRZEWCZE NA PALIWA STALE strumien masy popiolu (0 - 300) kg/h PN-M-34452:1999 p. 4.3.3","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"ash mass flow rate","range":"(0 - 300) kg/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC ash mass flow rate PN-M-34452:1999 p. 4.3.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-M-34452:1999 p. 4.3.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487751","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strumień masy żużla","range":"(0 - 300) kg/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy żużla (0 - 300) kg/h","reference":"PN-M-34452:1999 p. 4.3.3","norm_bases":["PN-M-34452:1999 p. 4.3.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE strumień masy żużla (0 - 300) kg/h PN-M-34452:1999 p. 4.3.3 KOTLY GRZEWCZE NA PALIWA STALE strumien masy zuzla (0 - 300) kg/h PN-M-34452:1999 p. 4.3.3","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"slag mass flow rate","range":"(0 - 300) kg/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC slag mass flow rate PN-M-34452:1999 p. 4.3.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-M-34452:1999 p. 4.3.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487752","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-M-34452:1999 p. 4.3.3","norm_bases":["PN-M-34452:1999 p. 4.3.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE PARAMETRY SPALIN: PN-M-34452:1999 p. 4.3.3 KOTLY GRZEWCZE NA PALIWA STALE PARAMETRY SPALIN: PN-M-34452:1999 p. 4.3.3","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-M-34452:1999 p. 4.3.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-M-34452:1999 p. 4.3.3","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"烟气参数："},{"_id":"6a7d7477ec6a53014a487753","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(0 - 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 - 600) °C","reference":"PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3","norm_bases":["PN-EN 303-5:2012 p. 5.7.3","PN-EN 303-5:2021-09 p. 5.6.3","PN-EN 303-5+A1:2023-05 p. 5.6.3","PN-EN 304:2017-11 rys.4,5,6","PN-M-34452:1999 p. 4.3.6.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE temperatura (0 - 600) °C PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3 KOTLY GRZEWCZE NA PALIWA STALE temperatura (0 - 600) °C PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(0 - 600) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3","parameters_zh":[{"name":"温度","range":"(0 - 600) °C"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487754","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3","norm_bases":["PN-EN 303-5:2012 p. 5.7.3","PN-EN 303-5:2021-09 p. 5.6.3","PN-EN 303-5+A1:2023-05 p. 5.6.3","PN-EN 304:2017-11 rys.4,5,6","PN-M-34452:1999 p. 4.3.6.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE ciśnienie (-10 - 10) hPa PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3 KOTLY GRZEWCZE NA PALIWA STALE cisnienie (-10 - 10) hPa PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487755","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","norm_bases":["PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 KOTLY GRZEWCZE NA PALIWA STALE Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO2; CO; PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a487756","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","norm_bases":["PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 KOTLY GRZEWCZE NA PALIWA STALE Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","categories":["environment","petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC NO OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC NO 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","parameters_zh":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"test_object_zh":"固体燃料供暖锅炉","technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a487757","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,002 - 1) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12","norm_bases":["PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-M–34452:1999 p. 4.3.8; 4.4.3.12"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE Stężenie pyłów w spalinach\nZakres (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12 KOTLY GRZEWCZE NA PALIWA STALE Stezenie pylow w spalinach\nZakres (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,002 - 1) g/m3"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Dust concentration in flue gases Gravimetric method Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Range PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12","technique_en":"Gravimetric method","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"范围","range":"(0,002 - 1) g/m3"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 烟气中粉尘浓度 重量法 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 范围 PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12","technique_zh":"重量法","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"烟气中粉尘浓度"},{"_id":"6a7d7477ec6a53014a487758","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"PARAMETRY POWIETRZA ATMOSFERYCZNEGO W MIEJSCU BADAŃ:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA ATMOSFERYCZNEGO W MIEJSCU BADAŃ:","reference":"PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12","norm_bases":["PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-M–34452:1999 p. 4.3.8; 4.4.3.12"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE PARAMETRY POWIETRZA ATMOSFERYCZNEGO W MIEJSCU BADAŃ: PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12 KOTLY GRZEWCZE NA PALIWA STALE PARAMETRY POWIETRZA ATMOSFERYCZNEGO W MIEJSCU BADAN: PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AMBIENT AIR PARAMETERS AT THE TEST SITE:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS AMBIENT AIR PARAMETERS AT THE TEST SITE: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487759","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(10-35)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10-35)°C","reference":"PN-EN 303-5:2012 p. 5.7.1; 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3 | PN-M–34452:1999 p. 4.2.7","norm_bases":["PN-EN 303-5:2012 p. 5.7.1; 5.7.3","PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3","PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3","PN-M–34452:1999 p. 4.2.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE temperatura (10-35)°C PN-EN 303-5:2012 p. 5.7.1; 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3 | PN-M–34452:1999 p. 4.2.7 KOTLY GRZEWCZE NA PALIWA STALE temperatura (10-35)°C PN-EN 303-5:2012 p. 5.7.1; 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3 | PN-M–34452:1999 p. 4.2.7","categories":["petro"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10-35)°C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 303-5:2012 p. 5.7.1; 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3 | PN-M–34452:1999 p. 4.2.7","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 303-5:2012 p. 5.7.1; 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3 | PN-M–34452:1999 p. 4.2.7","parameters_zh":[{"name":"温度","range":"(10-35)°C"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48775a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"ciśnienie","range":"(940-1060) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (940-1060) hPa","reference":"PN-EN 297:2002 p. 4.1.6.7","norm_bases":["PN-EN 297:2002 p. 4.1.6.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE ciśnienie (940-1060) hPa PN-EN 297:2002 p. 4.1.6.7 KOTLY GRZEWCZE NA PALIWA STALE cisnienie (940-1060) hPa PN-EN 297:2002 p. 4.1.6.7","categories":["petro"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(940-1060) hPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 297:2002 p. 4.1.6.7","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 297:2002 p. 4.1.6.7","parameters_zh":[{"name":"压力","range":"(940-1060) hPa"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48775b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 297:2002 p. 4.1.6.7","norm_bases":["PN-EN 297:2002 p. 4.1.6.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE BILANS CIEPLNY (z obliczeń): PN-EN 297:2002 p. 4.1.6.7 KOTLY GRZEWCZE NA PALIWA STALE BILANS CIEPLNY (z obliczen): PN-EN 297:2002 p. 4.1.6.7","categories":["petro"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 297:2002 p. 4.1.6.7","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 297:2002 p. 4.1.6.7","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d7477ec6a53014a48775c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna","range":"(1,5 - 1000) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna (1,5 - 1000) kW","reference":"PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1 | PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3","norm_bases":["PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1","PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1","PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1","PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE moc cieplna (1,5 - 1000) kW PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1 | PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3 KOTLY GRZEWCZE NA PALIWA STALE moc cieplna (1,5 - 1000) kW PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1 | PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3","categories":["petro"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output","range":"(1,5 - 1000) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1 | PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1 | PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48775d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(1,7 - 2000) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (1,7 - 2000) kW","reference":"PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2 | PN-M–34452:1999 p. 5.2","norm_bases":["PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2","PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2","PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2","PN-M–34452:1999 p. 5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE moc cieplna doprowadzona z paliwem (1,7 - 2000) kW PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2 | PN-M–34452:1999 p. 5.2 KOTLY GRZEWCZE NA PALIWA STALE moc cieplna doprowadzona z paliwem (1,7 - 2000) kW PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2 | PN-M–34452:1999 p. 5.2","categories":["petro"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(1,7 - 2000) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2 | PN-M–34452:1999 p. 5.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2 | PN-M–34452:1999 p. 5.2","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"燃料输入热功率","range":"(1,7 - 2000) kW"}]},{"_id":"6a7d7477ec6a53014a48775e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"weryfikacja nominalnej mocy cieplnej z kondensacją"}],"technique":null,"techniques":[],"computed":[],"activity":"weryfikacja nominalnej mocy cieplnej z kondensacją","reference":"PN-EN 303-5 +A1:2023-05 p. 5.7.4","norm_bases":["PN-EN 303-5 +A1:2023-05 p. 5.7.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE weryfikacja nominalnej mocy cieplnej z kondensacją PN-EN 303-5 +A1:2023-05 p. 5.7.4 KOTLY GRZEWCZE NA PALIWA STALE weryfikacja nominalnej mocy cieplnej z kondensacja PN-EN 303-5 +A1:2023-05 p. 5.7.4","categories":["petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"verification of the nominal heat output in condensing mode"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC verification of the nominal heat output in condensing mode PN-EN 303-5 +A1:2023-05 p. 5.7.4","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5 +A1:2023-05 p. 5.7.4","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48775f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"weryfikacja minimalnej mocy cieplne z kondensacją"}],"technique":null,"techniques":[],"computed":[],"activity":"weryfikacja minimalnej mocy cieplne z kondensacją","reference":"PN-EN 303-5 +A1:2023-05 p. 5.7.5","norm_bases":["PN-EN 303-5 +A1:2023-05 p. 5.7.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE weryfikacja minimalnej mocy cieplne z kondensacją PN-EN 303-5 +A1:2023-05 p. 5.7.5 KOTLY GRZEWCZE NA PALIWA STALE weryfikacja minimalnej mocy cieplne z kondensacja PN-EN 303-5 +A1:2023-05 p. 5.7.5","categories":["petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"verification of the minimum heat output in condensing mode"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC verification of the minimum heat output in condensing mode PN-EN 303-5 +A1:2023-05 p. 5.7.5","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5 +A1:2023-05 p. 5.7.5","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487760","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"pobór i weryfikacja składu kondensatu"}],"technique":null,"techniques":[],"computed":[],"activity":"pobór i weryfikacja składu kondensatu","reference":"PN-EN 303-5 +A1:2023-05 p. 5.12","norm_bases":["PN-EN 303-5 +A1:2023-05 p. 5.12"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE pobór i weryfikacja składu kondensatu PN-EN 303-5 +A1:2023-05 p. 5.12 KOTLY GRZEWCZE NA PALIWA STALE pobor i weryfikacja skladu kondensatu PN-EN 303-5 +A1:2023-05 p. 5.12","categories":["petro"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"sampling and verification of the condensate composition"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC sampling and verification of the condensate composition PN-EN 303-5 +A1:2023-05 p. 5.12","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5 +A1:2023-05 p. 5.12","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487761","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"bezpieczeństwo procesu kondensacji"}],"technique":null,"techniques":[],"computed":[],"activity":"bezpieczeństwo procesu kondensacji","reference":"PN-EN 303-5 +A1:2023-05 p. 5.17","norm_bases":["PN-EN 303-5 +A1:2023-05 p. 5.17"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE bezpieczeństwo procesu kondensacji PN-EN 303-5 +A1:2023-05 p. 5.17 KOTLY GRZEWCZE NA PALIWA STALE bezpieczenstwo procesu kondensacji PN-EN 303-5 +A1:2023-05 p. 5.17","categories":["petro"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"safety of the condensation process"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC safety of the condensation process PN-EN 303-5 +A1:2023-05 p. 5.17","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5 +A1:2023-05 p. 5.17","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487762","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"Efektywność (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Efektywność (z obliczeń)","reference":"PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 5.4","norm_bases":["PN-EN 303-5:2012 p.5.10.3","PN-EN 303-5:2021-09 p.5.9.3","PN-EN 303-5+A1:2023-05 p. 5.9.3","PN-M–34452:1999 p. 5.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE Efektywność (z obliczeń) PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 5.4 KOTLY GRZEWCZE NA PALIWA STALE Efektywnosc (z obliczen) PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 5.4","categories":["petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"Efficiency (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Efficiency (calculated) PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 5.4","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 5.4","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487763","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata kominowa","range":"(5-40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5-40) %","reference":"PN-EN 303-5:2012 p. 5.10.3.2 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.3; 5.6.1","norm_bases":["PN-EN 303-5:2012 p. 5.10.3.2","PN-EN 303-5:2021-09 p. 5.9.3","PN-EN 303-5+A1:2023-05 p. 5.9.3","PN-M–34452:1999 p. 4.4.3.3; 5.6.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE strata kominowa (5-40) % PN-EN 303-5:2012 p. 5.10.3.2 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.3; 5.6.1 KOTLY GRZEWCZE NA PALIWA STALE strata kominowa (5-40) % PN-EN 303-5:2012 p. 5.10.3.2 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.3; 5.6.1","categories":["petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5-40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 303-5:2012 p. 5.10.3.2 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.3; 5.6.1","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 303-5:2012 p. 5.10.3.2 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.3; 5.6.1","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"排烟热损失","range":"(5-40) %"}]},{"_id":"6a7d7477ec6a53014a487764","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.4; 5.6.2","norm_bases":["PN-EN 303-5:2012 p.5.10.3","PN-EN 303-5:2021-09 p. 5.9.3","PN-EN 303-5+A1:2023-05 p. 5.9.3","PN-M–34452:1999 p. 4.4.3.4; 5.6.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE straty niezupełnego spalania PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.4; 5.6.2 KOTLY GRZEWCZE NA PALIWA STALE straty niezupelnego spalania PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.4; 5.6.2","categories":["petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.4; 5.6.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.4; 5.6.2","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a487765","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata niecałkowitego spalania (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania (z obliczeń)","reference":"PN-EN 303-5:2012 p.5.10.3 | PN-M–34452:1999 p. 4.4.3.5; 5.6.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","norm_bases":["PN-EN 303-5:2012 p.5.10.3","PN-M–34452:1999 p. 4.4.3.5; 5.6.3","PN-EN 303-5:2021-09 p. 5.9.3","PN-EN 303-5+A1:2023-05 p. 5.9.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE strata niecałkowitego spalania (z obliczeń) PN-EN 303-5:2012 p.5.10.3 | PN-M–34452:1999 p. 4.4.3.5; 5.6.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 KOTLY GRZEWCZE NA PALIWA STALE strata niecalkowitego spalania (z obliczen) PN-EN 303-5:2012 p.5.10.3 | PN-M–34452:1999 p. 4.4.3.5; 5.6.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","categories":["petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion (calculated) PN-EN 303-5:2012 p.5.10.3 | PN-M–34452:1999 p. 4.4.3.5; 5.6.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p.5.10.3 | PN-M–34452:1999 p. 4.4.3.5; 5.6.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487766","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"straty do otoczenia"}],"technique":null,"techniques":[],"computed":[],"activity":"straty do otoczenia","reference":"PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","norm_bases":["PN-EN 304:2017-11 p. A.8.3","PN-M–34452:1999 p. 4.4.3.6; 5.6.4","PN-EN 303-5:2012 p.5.10.3","PN-EN 303-5:2021-09 p.5.9.3","PN-EN 303-5+A1:2023-05 p. 5.9.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE straty do otoczenia PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 KOTLY GRZEWCZE NA PALIWA STALE straty do otoczenia PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","categories":["petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses to the surroundings"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses to the surroundings PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487767","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE KOTŁA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE KOTŁA:","reference":"PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","norm_bases":["PN-EN 304:2017-11 p. A.8.3","PN-M–34452:1999 p. 4.4.3.6; 5.6.4","PN-EN 303-5:2012 p.5.10.3","PN-EN 303-5:2021-09 p.5.9.3","PN-EN 303-5+A1:2023-05 p. 5.9.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE PARAMETRY TECHNICZNO - EKSPLOATACYJNE KOTŁA: PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 KOTLY GRZEWCZE NA PALIWA STALE PARAMETRY TECHNICZNO - EKSPLOATACYJNE KOTLA: PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","categories":["petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS OF THE BOILER:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS TECHNICAL AND OPERATIONAL PARAMETERS OF THE BOILER: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487768","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"opory przepływu wody ciśnienie wody","range":"(10-2000) Pa"}],"technique":null,"techniques":[],"computed":[],"activity":"opory przepływu wody ciśnienie wody (10-2000) Pa","reference":"PN-EN 303-5:2012 p.5.11 | PN-EN 303-5:2021-09 p.5.10 | PN-EN 303-5+A1:2023-05 p. 5.10 | PN-EN 304:2017-11 p. 6.6","norm_bases":["PN-EN 303-5:2012 p.5.11","PN-EN 303-5:2021-09 p.5.10","PN-EN 303-5+A1:2023-05 p. 5.10","PN-EN 304:2017-11 p. 6.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE opory przepływu wody ciśnienie wody (10-2000) Pa PN-EN 303-5:2012 p.5.11 | PN-EN 303-5:2021-09 p.5.10 | PN-EN 303-5+A1:2023-05 p. 5.10 | PN-EN 304:2017-11 p. 6.6 KOTLY GRZEWCZE NA PALIWA STALE opory przeplywu wody cisnienie wody (10-2000) Pa PN-EN 303-5:2012 p.5.11 | PN-EN 303-5:2021-09 p.5.10 | PN-EN 303-5+A1:2023-05 p. 5.10 | PN-EN 304:2017-11 p. 6.6","categories":["water","petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"water flow resistance water pressure","range":"(10-2000) Pa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC water flow resistance water pressure PN-EN 303-5:2012 p.5.11 | PN-EN 303-5:2021-09 p.5.10 | PN-EN 303-5+A1:2023-05 p. 5.10 | PN-EN 304:2017-11 p. 6.6","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p.5.11 | PN-EN 303-5:2021-09 p.5.10 | PN-EN 303-5+A1:2023-05 p. 5.10 | PN-EN 304:2017-11 p. 6.6","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487769","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatury powierzchni zewnętrznych","range":"(0-200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatury powierzchni zewnętrznych (0-200) °C","reference":"PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16","norm_bases":["PN-EN 303-5:2012 p. 5.12","PN-EN 303-5:2021-09 p.5.11","PN-EN 303-5+A1:2023-05 p. 5.11","PN-M–34452:1999 p. 4.4.3.16"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE temperatury powierzchni zewnętrznych (0-200) °C PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16 KOTLY GRZEWCZE NA PALIWA STALE temperatury powierzchni zewnetrznych (0-200) °C PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16","categories":["petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperatures of external surfaces","range":"(0-200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperatures of external surfaces PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48776a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatury uchwytów","range":"(0-200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatury uchwytów (0-200) °C","reference":"PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16","norm_bases":["PN-EN 303-5:2012 p. 5.12","PN-EN 303-5:2021-09 p.5.11","PN-EN 303-5+A1:2023-05 p. 5.11","PN-M–34452:1999 p. 4.4.3.16"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE temperatury uchwytów (0-200) °C PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16 KOTLY GRZEWCZE NA PALIWA STALE temperatury uchwytow (0-200) °C PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16","categories":["petro"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperatures of handles","range":"(0-200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperatures of handles PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48776b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura podłoża pod kotłem","range":"(0-200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura podłoża pod kotłem (0-200) °C","reference":"PN-M–34452:1999 p. 4.4.3.16 | PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.12 | PN-EN 303-5+A1:2023-05 p. 5.12 | PN-EN 304:2017-11 p. 6.15","norm_bases":["PN-M–34452:1999 p. 4.4.3.16","PN-EN 303-5:2012 p. 5.12","PN-EN 303-5:2021-09 p.5.12","PN-EN 303-5+A1:2023-05 p. 5.12","PN-EN 304:2017-11 p. 6.15"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE temperatura podłoża pod kotłem (0-200) °C PN-M–34452:1999 p. 4.4.3.16 | PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.12 | PN-EN 303-5+A1:2023-05 p. 5.12 | PN-EN 304:2017-11 p. 6.15 KOTLY GRZEWCZE NA PALIWA STALE temperatura podloza pod kotlem (0-200) °C PN-M–34452:1999 p. 4.4.3.16 | PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.12 | PN-EN 303-5+A1:2023-05 p. 5.12 | PN-EN 304:2017-11 p. 6.15","categories":["petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the floor under the boiler","range":"(0-200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature of the floor under the boiler PN-M–34452:1999 p. 4.4.3.16 | PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.12 | PN-EN 303-5+A1:2023-05 p. 5.12 | PN-EN 304:2017-11 p. 6.15","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-M–34452:1999 p. 4.4.3.16 | PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.12 | PN-EN 303-5+A1:2023-05 p. 5.12 | PN-EN 304:2017-11 p. 6.15","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48776c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"badanie szczelności"}],"technique":null,"techniques":[],"computed":[],"activity":"badanie szczelności","reference":"PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1","norm_bases":["PN-EN 303-5:2012 p. 5.6","PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1","PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE badanie szczelności PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1 KOTLY GRZEWCZE NA PALIWA STALE badanie szczelnosci PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1","categories":["petro"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"leak-tightness testing"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC leak-tightness testing PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48776d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"DZIAŁANIE AUTOMATYCZNEJ REGULACJI I ZABEZPIECZEŃ:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"DZIAŁANIE AUTOMATYCZNEJ REGULACJI I ZABEZPIECZEŃ:","reference":"PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1","norm_bases":["PN-EN 303-5:2012 p. 5.6","PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1","PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE DZIAŁANIE AUTOMATYCZNEJ REGULACJI I ZABEZPIECZEŃ: PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1 KOTLY GRZEWCZE NA PALIWA STALE DZIALANIE AUTOMATYCZNEJ REGULACJI I ZABEZPIECZEN: PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1","categories":["petro"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"OPERATION OF AUTOMATIC CONTROLS AND SAFETY DEVICES:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS OPERATION OF AUTOMATIC CONTROLS AND SAFETY DEVICES: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48776e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"działanie regulatora temperatury wody i ogranicznika temperatury bezpieczeństwa","range":"(0-110)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"działanie regulatora temperatury wody i ogranicznika temperatury bezpieczeństwa (0-110)°C","reference":"PN-EN 303-5:2012 p. 5.13 | PN-EN 303-5:2021-09 p.5.13 | PN-EN 303-5+A1:2023-05 p. 5.13","norm_bases":["PN-EN 303-5:2012 p. 5.13","PN-EN 303-5:2021-09 p.5.13","PN-EN 303-5+A1:2023-05 p. 5.13"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE działanie regulatora temperatury wody i ogranicznika temperatury bezpieczeństwa (0-110)°C PN-EN 303-5:2012 p. 5.13 | PN-EN 303-5:2021-09 p.5.13 | PN-EN 303-5+A1:2023-05 p. 5.13 KOTLY GRZEWCZE NA PALIWA STALE dzialanie regulatora temperatury wody i ogranicznika temperatury bezpieczenstwa (0-110)°C PN-EN 303-5:2012 p. 5.13 | PN-EN 303-5:2021-09 p.5.13 | PN-EN 303-5+A1:2023-05 p. 5.13","categories":["water","petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"operation of the water temperature controller and the safety temperature limiter","range":"(0-110)°C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC operation of the water temperature controller and the safety temperature limiter PN-EN 303-5:2012 p. 5.13 | PN-EN 303-5:2021-09 p.5.13 | PN-EN 303-5+A1:2023-05 p. 5.13","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p. 5.13 | PN-EN 303-5:2021-09 p.5.13 | PN-EN 303-5+A1:2023-05 p. 5.13","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48776f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"działanie urządzenia do odprowadzania nadwyżki ciepła temperatura wody","range":"(0-120) °C"},{"name":"ciśnienie wody","range":"(0,1-0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ndziałanie urządzenia do odprowadzania nadwyżki ciepła temperatura wody (0-120) °C\nciśnienie wody (0,1-0,3) MPa","reference":"PN-EN 303-5:2012 p. 5.15 | PN-EN 303-5:2021-09 p. 5.15 | PN-EN 303-5+A1:2023-05 p. 5.15","norm_bases":["PN-EN 303-5:2012 p. 5.15","PN-EN 303-5:2021-09 p. 5.15","PN-EN 303-5+A1:2023-05 p. 5.15"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE Zakres:\ndziałanie urządzenia do odprowadzania nadwyżki ciepła temperatura wody (0-120) °C\nciśnienie wody (0,1-0,3) MPa PN-EN 303-5:2012 p. 5.15 | PN-EN 303-5:2021-09 p. 5.15 | PN-EN 303-5+A1:2023-05 p. 5.15 KOTLY GRZEWCZE NA PALIWA STALE Zakres:\ndzialanie urzadzenia do odprowadzania nadwyzki ciepla temperatura wody (0-120) °C\ncisnienie wody (0,1-0,3) MPa PN-EN 303-5:2012 p. 5.15 | PN-EN 303-5:2021-09 p. 5.15 | PN-EN 303-5+A1:2023-05 p. 5.15","categories":["water","petro"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"operation of the excess heat discharge device water temperature","range":"(0-120) °C"},{"name":"water pressure","range":"(0,1-0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC operation of the excess heat discharge device water temperature water pressure PN-EN 303-5:2012 p. 5.15 | PN-EN 303-5:2021-09 p. 5.15 | PN-EN 303-5+A1:2023-05 p. 5.15","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水压 PN-EN 303-5:2012 p. 5.15 | PN-EN 303-5:2021-09 p. 5.15 | PN-EN 303-5+A1:2023-05 p. 5.15","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"działanie urządzenia do odprowadzania nadwyżki ciepła temperatura wody","range":"(0-120) °C"},{"name":"水压","range":"(0,1-0,3) MPa"}]},{"_id":"6a7d7477ec6a53014a487770","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"działanie systemów szybko wyłączalnych"}],"technique":null,"techniques":[],"computed":[],"activity":"działanie systemów szybko wyłączalnych","reference":"PN-EN 303-5:2012 p. 5.14 | PN-EN 303-5 +A1:2023-05 p. 5.14","norm_bases":["PN-EN 303-5:2012 p. 5.14","PN-EN 303-5 +A1:2023-05 p. 5.14"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE działanie systemów szybko wyłączalnych PN-EN 303-5:2012 p. 5.14 | PN-EN 303-5 +A1:2023-05 p. 5.14 KOTLY GRZEWCZE NA PALIWA STALE dzialanie systemow szybko wylaczalnych PN-EN 303-5:2012 p. 5.14 | PN-EN 303-5 +A1:2023-05 p. 5.14","categories":["petro"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"operation of fast switch-off systems"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC operation of fast switch-off systems PN-EN 303-5:2012 p. 5.14 | PN-EN 303-5 +A1:2023-05 p. 5.14","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2012 p. 5.14 | PN-EN 303-5 +A1:2023-05 p. 5.14","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487771","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"bezpieczeństwo kotłów w warunkach przepełnienia paliwem i przy zablokowaniu zasilania paliwem"}],"technique":null,"techniques":[],"computed":[],"activity":"bezpieczeństwo kotłów w warunkach przepełnienia paliwem i przy zablokowaniu zasilania paliwem","reference":"PN-EN 303-5:2021-09 p. 5.16.2 | PN-EN 303-5 +A1:2023-05 p. 5.16.2","norm_bases":["PN-EN 303-5:2021-09 p. 5.16.2","PN-EN 303-5 +A1:2023-05 p. 5.16.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE bezpieczeństwo kotłów w warunkach przepełnienia paliwem i przy zablokowaniu zasilania paliwem PN-EN 303-5:2021-09 p. 5.16.2 | PN-EN 303-5 +A1:2023-05 p. 5.16.2 KOTLY GRZEWCZE NA PALIWA STALE bezpieczenstwo kotlow w warunkach przepelnienia paliwem i przy zablokowaniu zasilania paliwem PN-EN 303-5:2021-09 p. 5.16.2 | PN-EN 303-5 +A1:2023-05 p. 5.16.2","categories":["petro"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"safety of boilers under fuel overfilling conditions and when the fuel feed is blocked"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC safety of boilers under fuel overfilling conditions and when the fuel feed is blocked PN-EN 303-5:2021-09 p. 5.16.2 | PN-EN 303-5 +A1:2023-05 p. 5.16.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.16.2 | PN-EN 303-5 +A1:2023-05 p. 5.16.2","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487772","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"bezpieczeństwo kotłów przy zaniku dopływu powietrza"}],"technique":null,"techniques":[],"computed":[],"activity":"bezpieczeństwo kotłów przy zaniku dopływu powietrza","reference":"PN-EN 303-5:2021-09 p. 5.16.3 | PN-EN 303-5 +A1:2023-05 p. 5.16.3","norm_bases":["PN-EN 303-5:2021-09 p. 5.16.3","PN-EN 303-5 +A1:2023-05 p. 5.16.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE bezpieczeństwo kotłów przy zaniku dopływu powietrza PN-EN 303-5:2021-09 p. 5.16.3 | PN-EN 303-5 +A1:2023-05 p. 5.16.3 KOTLY GRZEWCZE NA PALIWA STALE bezpieczenstwo kotlow przy zaniku doplywu powietrza PN-EN 303-5:2021-09 p. 5.16.3 | PN-EN 303-5 +A1:2023-05 p. 5.16.3","categories":["petro"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"safety of boilers in the event of air supply failure"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC safety of boilers in the event of air supply failure PN-EN 303-5:2021-09 p. 5.16.3 | PN-EN 303-5 +A1:2023-05 p. 5.16.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.16.3 | PN-EN 303-5 +A1:2023-05 p. 5.16.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487773","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"bezpieczeństwo kotłów w zakresie przewodzenia ciepła"}],"technique":null,"techniques":[],"computed":[],"activity":"bezpieczeństwo kotłów w zakresie przewodzenia ciepła","reference":"PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4","norm_bases":["PN-EN 303-5:2021-09 p. 5.16.4","PN-EN 303-5 +A1:2023-05 p. 5.16.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE bezpieczeństwo kotłów w zakresie przewodzenia ciepła PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4 KOTLY GRZEWCZE NA PALIWA STALE bezpieczenstwo kotlow w zakresie przewodzenia ciepla PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4","categories":["petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"safety of boilers with respect to heat conduction"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC safety of boilers with respect to heat conduction PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a487774","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4","norm_bases":["PN-EN 303-5:2021-09 p. 5.16.4","PN-EN 303-5 +A1:2023-05 p. 5.16.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE PARAMETRY PALIWA: PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4 OGRZEWACZE POMIESZCZEN NA PALIWA STALE PARAMETRY PALIWA: PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4","categories":["petro"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 燃料参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4","methodology_zh":"燃料参数：","test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487775","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"(10-50) %"},{"name":"wartość opałowa (10-32) MJ/kg (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie (10-50) %\nwartość opałowa (10-32) MJ/kg (z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Zakres:\nzawartość wilgoci w drewnie (10-50) %\nwartość opałowa (10-32) MJ/kg (z obliczeń) Procedura nr LGP/42/B wyd. 4 OGRZEWACZE POMIESZCZEN NA PALIWA STALE Zakres:\nzawartosc wilgoci w drewnie (10-50) %\nwartosc opalowa (10-32) MJ/kg (z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"(10-50) %"},{"name":"net calorific value (10-32) MJ/kg (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (10-32) MJ/kg (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 Procedura nr LGP/42/B wyd. 4","test_object_zh":"固体燃料房间加热器","parameters_zh":[{"name":"木材含水率","range":"(10-50) %"},{"name":"wartość opałowa (10-32) MJ/kg (z obliczeń)"}]},{"_id":"6a7d7477ec6a53014a487776","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1-300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1-300) kg","reference":"PN-EN 13240:2008 p. A.4.2","norm_bases":["PN-EN 13240:2008 p. A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE masa paliwa (0,1-300) kg PN-EN 13240:2008 p. A.4.2 OGRZEWACZE POMIESZCZEN NA PALIWA STALE masa paliwa (0,1-300) kg PN-EN 13240:2008 p. A.4.2","categories":["petro"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1-300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 13240:2008 p. A.4.2","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 13240:2008 p. A.4.2","parameters_zh":[{"name":"燃料质量","range":"(0,1-300) kg"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487777","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 13240:2008 p. A.4.2","norm_bases":["PN-EN 13240:2008 p. A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE PARAMETRY SPALIN: PN-EN 13240:2008 p. A.4.2 OGRZEWACZE POMIESZCZEN NA PALIWA STALE PARAMETRY SPALIN: PN-EN 13240:2008 p. A.4.2","categories":["petro"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13240:2008 p. A.4.2","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13240:2008 p. A.4.2","methodology_zh":"烟气参数：","test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487778","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(15-1100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (15-1100) °C","reference":"PN-EN 13240:2008 p. A.4.4.3","norm_bases":["PN-EN 13240:2008 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE temperatura (15-1100) °C PN-EN 13240:2008 p. A.4.4.3 OGRZEWACZE POMIESZCZEN NA PALIWA STALE temperatura (15-1100) °C PN-EN 13240:2008 p. A.4.4.3","categories":["petro"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(15-1100) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 13240:2008 p. A.4.4.3","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 13240:2008 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(15-1100) °C"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487779","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 13240:2008 p. A2.3.4; A.4","norm_bases":["PN-EN 13240:2008 p. A2.3.4; A.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE ciśnienie (-10 - 10) hPa PN-EN 13240:2008 p. A2.3.4; A.4 OGRZEWACZE POMIESZCZEN NA PALIWA STALE cisnienie (-10 - 10) hPa PN-EN 13240:2008 p. A2.3.4; A.4","categories":["petro"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 13240:2008 p. A2.3.4; A.4","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 13240:2008 p. A2.3.4; A.4","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a48777a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2;","range":"(0,5-16) %"},{"name":"CO;","range":"(0,0003-4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5-16) %\nCO; (0,0003-4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 13240:2008 p. A.4.4.2","norm_bases":["PN-EN 13240:2008 p. A.4.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5-16) %\nCO; (0,0003-4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 13240:2008 p. A.4.4.2 OGRZEWACZE POMIESZCZEN NA PALIWA STALE Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2; (0,5-16) %\nCO; (0,0003-4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 13240:2008 p. A.4.4.2","categories":["petro"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2;","range":"(0,5-16) %"},{"name":"CO;","range":"(0,0003-4,0) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO2; CO; PN-EN 13240:2008 p. A.4.4.2","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13240:2008 p. A.4.4.2","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"固体燃料房间加热器","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a48777b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO;","range":"(5 - 440) mg/m3"},{"name":"OGC;","range":"(3,5-1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO; (5 - 440) mg/m3\nOGC; (3,5-1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Stężenia tlenku azotu, OGC.\nZakres:\nNO; (5 - 440) mg/m3\nOGC; (3,5-1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 OGRZEWACZE POMIESZCZEN NA PALIWA STALE Stezenia tlenku azotu, OGC.\nZakres:\nNO; (5 - 440) mg/m3\nOGC; (3,5-1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","categories":["environment","petro"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO;","range":"(5 - 440) mg/m3"},{"name":"OGC;","range":"(3,5-1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC NO; OGC; Emission of CO2; CO; NO; OGC (calculated) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO2、CO、NO、OGC 排放（由计算得出） PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","test_object_zh":"固体燃料房间加热器","parameters_zh":[{"name":"NO;","range":"(5 - 440) mg/m3"},{"name":"OGC;","range":"(3,5-1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a48777c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"stężenie pyłów w spalinach","range":"(0,002-1) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"stężenie pyłów w spalinach (0,002-1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE stężenie pyłów w spalinach (0,002-1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 OGRZEWACZE POMIESZCZEN NA PALIWA STALE stezenie pylow w spalinach (0,002-1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"dust concentration in flue gases","range":"(0,002-1) g/m3"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Gravimetric method Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC dust concentration in flue gases PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_en":"Gravimetric method","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 重量法 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_zh":"重量法","test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a48777d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 OGRZEWACZE POMIESZCZEN NA PALIWA STALE PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 空气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","methodology_zh":"空气参数：","test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a48777e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) °C","reference":"PN-EN 13240:2008 p. A.4.4.3","norm_bases":["PN-EN 13240:2008 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE temperatura (10 - 35) °C PN-EN 13240:2008 p. A.4.4.3 OGRZEWACZE POMIESZCZEN NA PALIWA STALE temperatura (10 - 35) °C PN-EN 13240:2008 p. A.4.4.3","categories":["petro"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 13240:2008 p. A.4.4.3","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 13240:2008 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) °C"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a48777f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 13240:2008 p. A.4.4.3","norm_bases":["PN-EN 13240:2008 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE PARAMETRY WODY: PN-EN 13240:2008 p. A.4.4.3 OGRZEWACZE POMIESZCZEN NA PALIWA STALE PARAMETRY WODY: PN-EN 13240:2008 p. A.4.4.3","categories":["water","petro"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13240:2008 p. A.4.4.3","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13240:2008 p. A.4.4.3","methodology_zh":"水参数：","test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487780","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 100)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 100)°C","reference":"PN-EN 13240:2008 p. A.4.5.2","norm_bases":["PN-EN 13240:2008 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE temperatura (10 - 100)°C PN-EN 13240:2008 p. A.4.5.2 OGRZEWACZE POMIESZCZEN NA PALIWA STALE temperatura (10 - 100)°C PN-EN 13240:2008 p. A.4.5.2","categories":["petro"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 100)°C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 13240:2008 p. A.4.5.2","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 13240:2008 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(10 - 100)°C"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487781","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 13240:2008 p. A.4.5.2","norm_bases":["PN-EN 13240:2008 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE strumień objętości (0 - 3) m3/h PN-EN 13240:2008 p. A.4.5.2 OGRZEWACZE POMIESZCZEN NA PALIWA STALE strumien objetosci (0 - 3) m3/h PN-EN 13240:2008 p. A.4.5.2","categories":["petro"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 13240:2008 p. A.4.5.2","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 13240:2008 p. A.4.5.2","test_object_zh":"固体燃料房间加热器","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a487782","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 13240:2008 p. A.4.5.2","norm_bases":["PN-EN 13240:2008 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE BILANS CIEPLNY (z obliczeń): PN-EN 13240:2008 p. A.4.5.2 OGRZEWACZE POMIESZCZEN NA PALIWA STALE BILANS CIEPLNY (z obliczen): PN-EN 13240:2008 p. A.4.5.2","categories":["petro"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13240:2008 p. A.4.5.2","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13240:2008 p. A.4.5.2","methodology_zh":"热平衡（计算值）：","test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487783","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 13240:2008 p. A.6.2.2","norm_bases":["PN-EN 13240:2008 p. A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 13240:2008 p. A.6.2.2 OGRZEWACZE POMIESZCZEN NA PALIWA STALE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 13240:2008 p. A.6.2.2","categories":["petro"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 13240:2008 p. A.6.2.2","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 13240:2008 p. A.6.2.2","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487784","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 13240:2008 p. A.6.2.1.1","norm_bases":["PN-EN 13240:2008 p. A.6.2.1.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE strata kominowa (5 - 40) % PN-EN 13240:2008 p. A.6.2.1.1 OGRZEWACZE POMIESZCZEN NA PALIWA STALE strata kominowa (5 - 40) % PN-EN 13240:2008 p. A.6.2.1.1","categories":["petro"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 13240:2008 p. A.6.2.1.1","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 13240:2008 p. A.6.2.1.1","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487785","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 13240:2008 p. A.6.2.1.2","norm_bases":["PN-EN 13240:2008 p. A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE straty niezupełnego spalania PN-EN 13240:2008 p. A.6.2.1.2 OGRZEWACZE POMIESZCZEN NA PALIWA STALE straty niezupelnego spalania PN-EN 13240:2008 p. A.6.2.1.2","categories":["petro"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 13240:2008 p. A.6.2.1.2","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 13240:2008 p. A.6.2.1.2","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487786","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 13240:2008 p. A.6.2.1.3","norm_bases":["PN-EN 13240:2008 p. A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE strata niecałkowitego spalania PN-EN 13240:2008 p. A.6.2.1.3 OGRZEWACZE POMIESZCZEN NA PALIWA STALE strata niecalkowitego spalania PN-EN 13240:2008 p. A.6.2.1.3","categories":["petro"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 13240:2008 p. A.6.2.1.3","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 13240:2008 p. A.6.2.1.3","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487787","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 13240:2008 p. A.6.2.1","norm_bases":["PN-EN 13240:2008 p. A.6.2.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE sprawność cieplna (20 - 95) % PN-EN 13240:2008 p. A.6.2.1 OGRZEWACZE POMIESZCZEN NA PALIWA STALE sprawnosc cieplna (20 - 95) % PN-EN 13240:2008 p. A.6.2.1","categories":["petro"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal efficiency PN-EN 13240:2008 p. A.6.2.1","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 热效率 PN-EN 13240:2008 p. A.6.2.1","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487788","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 - 50) kW","reference":"PN-EN 13240:2008 p. A.6.2.2","norm_bases":["PN-EN 13240:2008 p. A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE łączna moc cieplna (3 - 50) kW PN-EN 13240:2008 p. A.6.2.2 OGRZEWACZE POMIESZCZEN NA PALIWA STALE laczna moc cieplna (3 - 50) kW PN-EN 13240:2008 p. A.6.2.2","categories":["petro"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(3 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC total heat output PN-EN 13240:2008 p. A.6.2.2","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 总热功率 PN-EN 13240:2008 p. A.6.2.2","parameters_zh":[{"name":"总热功率","range":"(3 - 50) kW"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487789","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(3 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (3 - 50) kW","reference":"PN-EN 13240:2008 p. A.6.2.3","norm_bases":["PN-EN 13240:2008 p. A.6.2.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE moc cieplna obiegu wodnego (3 - 50) kW PN-EN 13240:2008 p. A.6.2.3 OGRZEWACZE POMIESZCZEN NA PALIWA STALE moc cieplna obiegu wodnego (3 - 50) kW PN-EN 13240:2008 p. A.6.2.3","categories":["petro"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(3 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output of the water circuit PN-EN 13240:2008 p. A.6.2.3","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水循环回路热功率 PN-EN 13240:2008 p. A.6.2.3","test_object_zh":"固体燃料房间加热器","parameters_zh":[{"name":"水循环回路热功率","range":"(3 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a48778a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 - 50) kW","reference":"PN-EN 13240:2008 p. A.6.2.4","norm_bases":["PN-EN 13240:2008 p. A.6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE moc cieplna oddawana do pomieszczenia (3 - 50) kW PN-EN 13240:2008 p. A.6.2.4 OGRZEWACZE POMIESZCZEN NA PALIWA STALE moc cieplna oddawana do pomieszczenia (3 - 50) kW PN-EN 13240:2008 p. A.6.2.4","categories":["petro"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(3 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 13240:2008 p. A.6.2.4","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 13240:2008 p. A.6.2.4","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 - 50) kW"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a48778b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4)%"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4)%","reference":"PN-EN 13240:2008 p. A.6.2.6","norm_bases":["PN-EN 13240:2008 p. A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE zawartość CO (O2=13%) (0 - 4)% PN-EN 13240:2008 p. A.6.2.6 OGRZEWACZE POMIESZCZEN NA PALIWA STALE zawartosc CO (O2=13%) (0 - 4)% PN-EN 13240:2008 p. A.6.2.6","categories":["petro"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4)%"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 13240:2008 p. A.6.2.6","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 13240:2008 p. A.6.2.6","test_object_zh":"固体燃料房间加热器","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4)%"}]},{"_id":"6a7d7477ec6a53014a48778c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 13240:2008 p. A.6.2.6","norm_bases":["PN-EN 13240:2008 p. A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 13240:2008 p. A.6.2.6 OGRZEWACZE POMIESZCZEN NA PALIWA STALE PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 13240:2008 p. A.6.2.6","categories":["petro"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13240:2008 p. A.6.2.6","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 技术与运行参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13240:2008 p. A.6.2.6","test_object_zh":"固体燃料房间加热器","methodology_zh":"技术与运行参数："},{"_id":"6a7d7477ec6a53014a48778d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200) °C"},{"name":"temperatura uchwytów","range":"(0 - 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C\ntemperatura uchwytów (0 - 200) °C","reference":"PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9","norm_bases":["PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C\ntemperatura uchwytów (0 - 200) °C PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9 OGRZEWACZE POMIESZCZEN NA PALIWA STALE Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C\ntemperatura uchwytow (0 - 200) °C PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9","categories":["petro"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 - 200) °C"},{"name":"temperature of handles","range":"(0 - 200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) °C"},{"name":"燃料储斗温度","range":"(0 - 200) °C"},{"name":"手柄温度","range":"(0 - 200) °C"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a48778e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 13240:2008 p. A.4.9.4","norm_bases":["PN-EN 13240:2008 p. A.4.9.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 13240:2008 p. A.4.9.4 OGRZEWACZE POMIESZCZEN NA PALIWA STALE szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 13240:2008 p. A.4.9.4","categories":["petro"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness of the water space PN-EN 13240:2008 p. A.4.9.4","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水腔密封性 PN-EN 13240:2008 p. A.4.9.4","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a48778f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) °C"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) °C\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 13240:2008 p. A.4.9.5","norm_bases":["PN-EN 13240:2008 p. A.4.9.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) °C\nciśnienie wody (0,1 - 0,3) MPa PN-EN 13240:2008 p. A.4.9.5 OGRZEWACZE POMIESZCZEN NA PALIWA STALE Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) °C\ncisnienie wody (0,1 - 0,3) MPa PN-EN 13240:2008 p. A.4.9.5","categories":["water","petro"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) °C"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 13240:2008 p. A.4.9.5","test_object_en":"SOLID FUEL LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 13240:2008 p. A.4.9.5","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) °C"},{"name":"水压","range":"(0,1 - 0,3) MPa"}],"test_object_zh":"固体燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487790","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 13240:2008 p. A.4.9.5","norm_bases":["PN-EN 13240:2008 p. A.4.9.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE PARAMETRY PALIWA: PN-EN 13240:2008 p. A.4.9.5 WKLADY KOMINKOWE NA PALIWA STALE PARAMETRY PALIWA: PN-EN 13240:2008 p. A.4.9.5","categories":["petro"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13240:2008 p. A.4.9.5","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 燃料参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13240:2008 p. A.4.9.5","methodology_zh":"燃料参数：","test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a487791","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"( 10 - 50) %"},{"name":"wartość opałowa (10 - 32) MJ/kg (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie ( 10 - 50) %\nwartość opałowa (10 - 32) MJ/kg (z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE Zakres:\nzawartość wilgoci w drewnie ( 10 - 50) %\nwartość opałowa (10 - 32) MJ/kg (z obliczeń) Procedura nr LGP/42/B wyd. 4 WKLADY KOMINKOWE NA PALIWA STALE Zakres:\nzawartosc wilgoci w drewnie ( 10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg (z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"( 10 - 50) %"},{"name":"net calorific value (10 - 32) MJ/kg (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (10 - 32) MJ/kg (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 (10 - 32) MJ/kg（由计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"固体燃料壁炉芯","parameters_zh":[{"name":"木材含水率","range":"( 10 - 50) %"},{"name":"低位发热量 (10 - 32) MJ/kg（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a487792","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 13229:2002 p. A.4.2","norm_bases":["PN-EN 13229:2002 p. A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE masa paliwa (0,1 - 300) kg PN-EN 13229:2002 p. A.4.2 WKLADY KOMINKOWE NA PALIWA STALE masa paliwa (0,1 - 300) kg PN-EN 13229:2002 p. A.4.2","categories":["petro"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 13229:2002 p. A.4.2","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 13229:2002 p. A.4.2","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a487793","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 13229:2002 p. A.4.2","norm_bases":["PN-EN 13229:2002 p. A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE PARAMETRY SPALIN: PN-EN 13229:2002 p. A.4.2 WKLADY KOMINKOWE NA PALIWA STALE PARAMETRY SPALIN: PN-EN 13229:2002 p. A.4.2","categories":["petro"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13229:2002 p. A.4.2","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13229:2002 p. A.4.2","methodology_zh":"烟气参数：","test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a487794","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(0 - 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 - 600) °C","reference":"PN-EN 13229:2002 p. A.4.4.3","norm_bases":["PN-EN 13229:2002 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE temperatura (0 - 600) °C PN-EN 13229:2002 p. A.4.4.3 WKLADY KOMINKOWE NA PALIWA STALE temperatura (0 - 600) °C PN-EN 13229:2002 p. A.4.4.3","categories":["petro"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(0 - 600) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 13229:2002 p. A.4.4.3","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 13229:2002 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(0 - 600) °C"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a487795","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 13229:2002 p. A2.3.4;A.4","norm_bases":["PN-EN 13229:2002 p. A2.3.4;A.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE ciśnienie (-10 - 10) hPa PN-EN 13229:2002 p. A2.3.4;A.4 WKLADY KOMINKOWE NA PALIWA STALE cisnienie (-10 - 10) hPa PN-EN 13229:2002 p. A2.3.4;A.4","categories":["petro"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 13229:2002 p. A2.3.4;A.4","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 13229:2002 p. A2.3.4;A.4","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a487796","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 13229:2002 p. A.4.4.2","norm_bases":["PN-EN 13229:2002 p. A.4.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 13229:2002 p. A.4.4.2 WKLADY KOMINKOWE NA PALIWA STALE Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 13229:2002 p. A.4.4.2","categories":["petro"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO2; CO; PN-EN 13229:2002 p. A.4.4.2","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13229:2002 p. A.4.4.2","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"固体燃料壁炉芯","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a487797","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 WKLADY KOMINKOWE NA PALIWA STALE Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","categories":["environment","petro"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC NO OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC NO 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","parameters_zh":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"test_object_zh":"固体燃料壁炉芯","technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a487798","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,002 - 1) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE Stężenie pyłów w spalinach\nZakres (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 WKLADY KOMINKOWE NA PALIWA STALE Stezenie pylow w spalinach\nZakres (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,002 - 1) g/m3"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Dust concentration in flue gases Gravimetric method Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Range PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_en":"Gravimetric method","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"范围","range":"(0,002 - 1) g/m3"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 烟气中粉尘浓度 重量法 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 范围 PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_zh":"重量法","test_object_zh":"固体燃料壁炉芯","methodology_zh":"烟气中粉尘浓度"},{"_id":"6a7d7477ec6a53014a487799","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 WKLADY KOMINKOWE NA PALIWA STALE PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 空气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","methodology_zh":"空气参数：","test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a48779a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) °C","reference":"PN-EN 13229:2002 p. A.4.4.3","norm_bases":["PN-EN 13229:2002 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE temperatura (10 - 35) °C PN-EN 13229:2002 p. A.4.4.3 WKLADY KOMINKOWE NA PALIWA STALE temperatura (10 - 35) °C PN-EN 13229:2002 p. A.4.4.3","categories":["petro"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 13229:2002 p. A.4.4.3","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 13229:2002 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) °C"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a48779b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 13229:2002 p. A.4.4.3","norm_bases":["PN-EN 13229:2002 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE PARAMETRY WODY: PN-EN 13229:2002 p. A.4.4.3 WKLADY KOMINKOWE NA PALIWA STALE PARAMETRY WODY: PN-EN 13229:2002 p. A.4.4.3","categories":["water","petro"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13229:2002 p. A.4.4.3","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13229:2002 p. A.4.4.3","methodology_zh":"水参数：","test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a48779c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(0 - 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 - 100) °C","reference":"PN-EN 13229:2002 p. A.4.5.2","norm_bases":["PN-EN 13229:2002 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE temperatura (0 - 100) °C PN-EN 13229:2002 p. A.4.5.2 WKLADY KOMINKOWE NA PALIWA STALE temperatura (0 - 100) °C PN-EN 13229:2002 p. A.4.5.2","categories":["petro"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(0 - 100) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 13229:2002 p. A.4.5.2","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 13229:2002 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(0 - 100) °C"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a48779d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 13229:2002 p. A.4.5.2","norm_bases":["PN-EN 13229:2002 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE strumień objętości (0 - 3) m3/h PN-EN 13229:2002 p. A.4.5.2 WKLADY KOMINKOWE NA PALIWA STALE strumien objetosci (0 - 3) m3/h PN-EN 13229:2002 p. A.4.5.2","categories":["petro"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 13229:2002 p. A.4.5.2","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 13229:2002 p. A.4.5.2","test_object_zh":"固体燃料壁炉芯","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a48779e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 13229:2002 p. A.4.5.2","norm_bases":["PN-EN 13229:2002 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE BILANS CIEPLNY (z obliczeń): PN-EN 13229:2002 p. A.4.5.2 WKLADY KOMINKOWE NA PALIWA STALE BILANS CIEPLNY (z obliczen): PN-EN 13229:2002 p. A.4.5.2","categories":["petro"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13229:2002 p. A.4.5.2","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13229:2002 p. A.4.5.2","methodology_zh":"热平衡（计算值）：","test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a48779f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 13229:2002 p. A.6.2.2","norm_bases":["PN-EN 13229:2002 p. A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 13229:2002 p. A.6.2.2 WKLADY KOMINKOWE NA PALIWA STALE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 13229:2002 p. A.6.2.2","categories":["petro"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 13229:2002 p. A.6.2.2","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 13229:2002 p. A.6.2.2","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877a0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 13229:2002 p. A.6.2.1.1","norm_bases":["PN-EN 13229:2002 p. A.6.2.1.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE strata kominowa (5 - 40) % PN-EN 13229:2002 p. A.6.2.1.1 WKLADY KOMINKOWE NA PALIWA STALE strata kominowa (5 - 40) % PN-EN 13229:2002 p. A.6.2.1.1","categories":["petro"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 13229:2002 p. A.6.2.1.1","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 13229:2002 p. A.6.2.1.1","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877a1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 13229:2002 p. A.6.2.1.2","norm_bases":["PN-EN 13229:2002 p. A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE straty niezupełnego spalania PN-EN 13229:2002 p. A.6.2.1.2 WKLADY KOMINKOWE NA PALIWA STALE straty niezupelnego spalania PN-EN 13229:2002 p. A.6.2.1.2","categories":["petro"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 13229:2002 p. A.6.2.1.2","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 13229:2002 p. A.6.2.1.2","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877a2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 13229:2002 p. A.6.2.1.3","norm_bases":["PN-EN 13229:2002 p. A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE strata niecałkowitego spalania PN-EN 13229:2002 p. A.6.2.1.3 WKLADY KOMINKOWE NA PALIWA STALE strata niecalkowitego spalania PN-EN 13229:2002 p. A.6.2.1.3","categories":["petro"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 13229:2002 p. A.6.2.1.3","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 13229:2002 p. A.6.2.1.3","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877a3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 13229:2002 p. A.6.2.1","norm_bases":["PN-EN 13229:2002 p. A.6.2.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE sprawność cieplna (20 - 95) % PN-EN 13229:2002 p. A.6.2.1 WKLADY KOMINKOWE NA PALIWA STALE sprawnosc cieplna (20 - 95) % PN-EN 13229:2002 p. A.6.2.1","categories":["petro"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal efficiency PN-EN 13229:2002 p. A.6.2.1","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 热效率 PN-EN 13229:2002 p. A.6.2.1","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877a4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 - 50) kW","reference":"PN-EN 13229:2002 p. A.6.2.2","norm_bases":["PN-EN 13229:2002 p. A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE łączna moc cieplna (3 - 50) kW PN-EN 13229:2002 p. A.6.2.2 WKLADY KOMINKOWE NA PALIWA STALE laczna moc cieplna (3 - 50) kW PN-EN 13229:2002 p. A.6.2.2","categories":["petro"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(3 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC total heat output PN-EN 13229:2002 p. A.6.2.2","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 总热功率 PN-EN 13229:2002 p. A.6.2.2","parameters_zh":[{"name":"总热功率","range":"(3 - 50) kW"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877a5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(0 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (0 - 50) kW","reference":"PN-EN 13229:2002 p. A.6.2.3","norm_bases":["PN-EN 13229:2002 p. A.6.2.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE moc cieplna obiegu wodnego (0 - 50) kW PN-EN 13229:2002 p. A.6.2.3 WKLADY KOMINKOWE NA PALIWA STALE moc cieplna obiegu wodnego (0 - 50) kW PN-EN 13229:2002 p. A.6.2.3","categories":["petro"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(0 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output of the water circuit PN-EN 13229:2002 p. A.6.2.3","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水循环回路热功率 PN-EN 13229:2002 p. A.6.2.3","test_object_zh":"固体燃料壁炉芯","parameters_zh":[{"name":"水循环回路热功率","range":"(0 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a4877a6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 - 50) kW","reference":"PN-EN 13229:2002 p. A.6.2.4","norm_bases":["PN-EN 13229:2002 p. A.6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE moc cieplna oddawana do pomieszczenia (3 - 50) kW PN-EN 13229:2002 p. A.6.2.4 WKLADY KOMINKOWE NA PALIWA STALE moc cieplna oddawana do pomieszczenia (3 - 50) kW PN-EN 13229:2002 p. A.6.2.4","categories":["petro"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(3 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 13229:2002 p. A.6.2.4","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 13229:2002 p. A.6.2.4","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 - 50) kW"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877a7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4) %","reference":"PN-EN 13229:2002 p. A.6.2.6","norm_bases":["PN-EN 13229:2002 p. A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE zawartość CO (O2=13%) (0 - 4) % PN-EN 13229:2002 p. A.6.2.6 WKLADY KOMINKOWE NA PALIWA STALE zawartosc CO (O2=13%) (0 - 4) % PN-EN 13229:2002 p. A.6.2.6","categories":["petro"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 13229:2002 p. A.6.2.6","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 13229:2002 p. A.6.2.6","test_object_zh":"固体燃料壁炉芯","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4) %"}]},{"_id":"6a7d7477ec6a53014a4877a8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"PARAMETRY TECHNICZNO – EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO – EKSPLOATACYJNE:","reference":"PN-EN 13229:2002 p. A.6.2.6","norm_bases":["PN-EN 13229:2002 p. A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE PARAMETRY TECHNICZNO – EKSPLOATACYJNE: PN-EN 13229:2002 p. A.6.2.6 WKLADY KOMINKOWE NA PALIWA STALE PARAMETRY TECHNICZNO – EKSPLOATACYJNE: PN-EN 13229:2002 p. A.6.2.6","categories":["petro"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13229:2002 p. A.6.2.6","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13229:2002 p. A.6.2.6","test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877a9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200)°C"},{"name":"temperatura uchwytów","range":"(0 - 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200)°C\ntemperatura uchwytów (0 - 200) °C","reference":"PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9","norm_bases":["PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200)°C\ntemperatura uchwytów (0 - 200) °C PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9 WKLADY KOMINKOWE NA PALIWA STALE Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200)°C\ntemperatura uchwytow (0 - 200) °C PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9","categories":["petro"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 - 200)°C"},{"name":"temperature of handles","range":"(0 - 200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) °C"},{"name":"燃料储斗温度","range":"(0 - 200)°C"},{"name":"手柄温度","range":"(0 - 200) °C"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877aa","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 13229:2002 p. A.4.9.5","norm_bases":["PN-EN 13229:2002 p. A.4.9.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 13229:2002 p. A.4.9.5 WKLADY KOMINKOWE NA PALIWA STALE szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 13229:2002 p. A.4.9.5","categories":["petro"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness of the water space PN-EN 13229:2002 p. A.4.9.5","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水腔密封性 PN-EN 13229:2002 p. A.4.9.5","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877ab","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"WKŁADY KOMINKOWE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) °C"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) °C\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 13229:2002 p. A.4.9.6","norm_bases":["PN-EN 13229:2002 p. A.4.9.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"WKŁADY KOMINKOWE NA PALIWA STAŁE Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) °C\nciśnienie wody (0,1 - 0,3) MPa PN-EN 13229:2002 p. A.4.9.6 WKLADY KOMINKOWE NA PALIWA STALE Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) °C\ncisnienie wody (0,1 - 0,3) MPa PN-EN 13229:2002 p. A.4.9.6","categories":["water","petro"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) °C"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL FIREPLACE INSERTS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 13229:2002 p. A.4.9.6","test_object_en":"SOLID FUEL FIREPLACE INSERTS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料壁炉芯 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 13229:2002 p. A.4.9.6","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) °C"},{"name":"水压","range":"(0,1 - 0,3) MPa"}],"test_object_zh":"固体燃料壁炉芯"},{"_id":"6a7d7477ec6a53014a4877ac","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 13229:2002 p. A.4.9.6","norm_bases":["PN-EN 13229:2002 p. A.4.9.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE PARAMETRY PALIWA: PN-EN 13229:2002 p. A.4.9.6 KUCHNIE NA PALIWA STALE PARAMETRY PALIWA: PN-EN 13229:2002 p. A.4.9.6","categories":["petro"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 13229:2002 p. A.4.9.6","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 燃料参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 13229:2002 p. A.4.9.6","methodology_zh":"燃料参数：","test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877ad","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie"},{"name":"wartość opałowa (10 - 32) MJ/kg (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie\nwartość opałowa (10 - 32) MJ/kg (z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE Zakres:\nzawartość wilgoci w drewnie\nwartość opałowa (10 - 32) MJ/kg (z obliczeń) Procedura nr LGP/42/B wyd. 4 KUCHNIE NA PALIWA STALE Zakres:\nzawartosc wilgoci w drewnie\nwartosc opalowa (10 - 32) MJ/kg (z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood"},{"name":"net calorific value (10 - 32) MJ/kg (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (10 - 32) MJ/kg (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 (10 - 32) MJ/kg（由计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"固体燃料炊具","parameters_zh":[{"name":"木材含水率"},{"name":"低位发热量 (10 - 32) MJ/kg（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a4877ae","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 12815:2004 p. A.4.2","norm_bases":["PN-EN 12815:2004 p. A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE masa paliwa (0,1 - 300) kg PN-EN 12815:2004 p. A.4.2 KUCHNIE NA PALIWA STALE masa paliwa (0,1 - 300) kg PN-EN 12815:2004 p. A.4.2","categories":["petro"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 12815:2004 p. A.4.2","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 12815:2004 p. A.4.2","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877af","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 12815:2004 p. A.4.2","norm_bases":["PN-EN 12815:2004 p. A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE PARAMETRY SPALIN: PN-EN 12815:2004 p. A.4.2 KUCHNIE NA PALIWA STALE PARAMETRY SPALIN: PN-EN 12815:2004 p. A.4.2","categories":["petro"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12815:2004 p. A.4.2","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12815:2004 p. A.4.2","methodology_zh":"烟气参数：","test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877b0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(0 - 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 - 600) °C","reference":"PN-EN 12815:2004 p. A.2.3.2; A.4.4.3","norm_bases":["PN-EN 12815:2004 p. A.2.3.2; A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE temperatura (0 - 600) °C PN-EN 12815:2004 p. A.2.3.2; A.4.4.3 KUCHNIE NA PALIWA STALE temperatura (0 - 600) °C PN-EN 12815:2004 p. A.2.3.2; A.4.4.3","categories":["petro"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(0 - 600) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 12815:2004 p. A.2.3.2; A.4.4.3","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 12815:2004 p. A.2.3.2; A.4.4.3","parameters_zh":[{"name":"温度","range":"(0 - 600) °C"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877b1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 12815:2004 p. A.2.3.4.","norm_bases":["PN-EN 12815:2004 p. A.2.3.4."],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE ciśnienie (-10 - 10) hPa PN-EN 12815:2004 p. A.2.3.4. KUCHNIE NA PALIWA STALE cisnienie (-10 - 10) hPa PN-EN 12815:2004 p. A.2.3.4.","categories":["petro"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 12815:2004 p. A.2.3.4.","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 12815:2004 p. A.2.3.4.","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877b2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 12815:2004 p. A.2.3; A.4.4.2","norm_bases":["PN-EN 12815:2004 p. A.2.3; A.4.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 12815:2004 p. A.2.3; A.4.4.2 KUCHNIE NA PALIWA STALE Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 12815:2004 p. A.2.3; A.4.4.2","categories":["petro"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO2; CO; PN-EN 12815:2004 p. A.2.3; A.4.4.2","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12815:2004 p. A.2.3; A.4.4.2","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"固体燃料炊具","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a4877b3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 KUCHNIE NA PALIWA STALE Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","categories":["environment","petro"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC NO OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC NO 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","parameters_zh":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"test_object_zh":"固体燃料炊具","technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a4877b4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,005 - 1) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,005 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE Stężenie pyłów w spalinach\nZakres (0,005 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 KUCHNIE NA PALIWA STALE Stezenie pylow w spalinach\nZakres (0,005 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,005 - 1) g/m3"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Dust concentration in flue gases Gravimetric method Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Range PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_en":"Gravimetric method","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"范围","range":"(0,005 - 1) g/m3"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 烟气中粉尘浓度 重量法 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 范围 PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_zh":"重量法","test_object_zh":"固体燃料炊具","methodology_zh":"烟气中粉尘浓度"},{"_id":"6a7d7477ec6a53014a4877b5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 KUCHNIE NA PALIWA STALE PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 空气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","methodology_zh":"空气参数：","test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877b6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) °C","reference":"PN-EN 12815:2004 p. A.1.1; A.4.4.3","norm_bases":["PN-EN 12815:2004 p. A.1.1; A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE temperatura (10 - 35) °C PN-EN 12815:2004 p. A.1.1; A.4.4.3 KUCHNIE NA PALIWA STALE temperatura (10 - 35) °C PN-EN 12815:2004 p. A.1.1; A.4.4.3","categories":["petro"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 12815:2004 p. A.1.1; A.4.4.3","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 12815:2004 p. A.1.1; A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) °C"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877b7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 12815:2004 p. A.1.1; A.4.4.3","norm_bases":["PN-EN 12815:2004 p. A.1.1; A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE PARAMETRY WODY: PN-EN 12815:2004 p. A.1.1; A.4.4.3 KUCHNIE NA PALIWA STALE PARAMETRY WODY: PN-EN 12815:2004 p. A.1.1; A.4.4.3","categories":["water","petro"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12815:2004 p. A.1.1; A.4.4.3","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12815:2004 p. A.1.1; A.4.4.3","methodology_zh":"水参数：","test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877b8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(0 - 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 - 100) °C","reference":"PN-EN 12815:2004 p. A.2.5; A.4.5","norm_bases":["PN-EN 12815:2004 p. A.2.5; A.4.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE temperatura (0 - 100) °C PN-EN 12815:2004 p. A.2.5; A.4.5 KUCHNIE NA PALIWA STALE temperatura (0 - 100) °C PN-EN 12815:2004 p. A.2.5; A.4.5","categories":["petro"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(0 - 100) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 12815:2004 p. A.2.5; A.4.5","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 12815:2004 p. A.2.5; A.4.5","parameters_zh":[{"name":"温度","range":"(0 - 100) °C"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877b9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 12815:2004 p. A.2.5; A.4.5","norm_bases":["PN-EN 12815:2004 p. A.2.5; A.4.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE strumień objętości (0 - 3) m3/h PN-EN 12815:2004 p. A.2.5; A.4.5 KUCHNIE NA PALIWA STALE strumien objetosci (0 - 3) m3/h PN-EN 12815:2004 p. A.2.5; A.4.5","categories":["petro"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 12815:2004 p. A.2.5; A.4.5","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 12815:2004 p. A.2.5; A.4.5","test_object_zh":"固体燃料炊具","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a4877ba","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 12815:2004 p. A.2.5; A.4.5","norm_bases":["PN-EN 12815:2004 p. A.2.5; A.4.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE BILANS CIEPLNY (z obliczeń): PN-EN 12815:2004 p. A.2.5; A.4.5 KUCHNIE NA PALIWA STALE BILANS CIEPLNY (z obliczen): PN-EN 12815:2004 p. A.2.5; A.4.5","categories":["petro"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12815:2004 p. A.2.5; A.4.5","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12815:2004 p. A.2.5; A.4.5","methodology_zh":"热平衡（计算值）：","test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877bb","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2","norm_bases":["PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2 KUCHNIE NA PALIWA STALE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2","categories":["petro"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877bc","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 12815:2004 p. A.4.4; A.6.2.1.1","norm_bases":["PN-EN 12815:2004 p. A.4.4; A.6.2.1.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE strata kominowa (5 - 40) % PN-EN 12815:2004 p. A.4.4; A.6.2.1.1 KUCHNIE NA PALIWA STALE strata kominowa (5 - 40) % PN-EN 12815:2004 p. A.4.4; A.6.2.1.1","categories":["petro"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 12815:2004 p. A.4.4; A.6.2.1.1","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 12815:2004 p. A.4.4; A.6.2.1.1","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877bd","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 12815:2004 p. A.4.4; A.6.2.1.2","norm_bases":["PN-EN 12815:2004 p. A.4.4; A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE straty niezupełnego spalania PN-EN 12815:2004 p. A.4.4; A.6.2.1.2 KUCHNIE NA PALIWA STALE straty niezupelnego spalania PN-EN 12815:2004 p. A.4.4; A.6.2.1.2","categories":["petro"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 12815:2004 p. A.4.4; A.6.2.1.2","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 12815:2004 p. A.4.4; A.6.2.1.2","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877be","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 12815:2004 p. A.4.6; A.6.2.1.3","norm_bases":["PN-EN 12815:2004 p. A.4.6; A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE strata niecałkowitego spalania PN-EN 12815:2004 p. A.4.6; A.6.2.1.3 KUCHNIE NA PALIWA STALE strata niecalkowitego spalania PN-EN 12815:2004 p. A.4.6; A.6.2.1.3","categories":["petro"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 12815:2004 p. A.4.6; A.6.2.1.3","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 12815:2004 p. A.4.6; A.6.2.1.3","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877bf","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 12815:2004 p. A.6.2.1","norm_bases":["PN-EN 12815:2004 p. A.6.2.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE sprawność cieplna (20 - 95) % PN-EN 12815:2004 p. A.6.2.1 KUCHNIE NA PALIWA STALE sprawnosc cieplna (20 - 95) % PN-EN 12815:2004 p. A.6.2.1","categories":["petro"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal efficiency PN-EN 12815:2004 p. A.6.2.1","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 热效率 PN-EN 12815:2004 p. A.6.2.1","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877c0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 - 50)kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 - 50)kW","reference":"PN-EN 12815:2004 p. A.6.2.2","norm_bases":["PN-EN 12815:2004 p. A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE łączna moc cieplna (3 - 50)kW PN-EN 12815:2004 p. A.6.2.2 KUCHNIE NA PALIWA STALE laczna moc cieplna (3 - 50)kW PN-EN 12815:2004 p. A.6.2.2","categories":["petro"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(3 - 50)kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC total heat output PN-EN 12815:2004 p. A.6.2.2","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 总热功率 PN-EN 12815:2004 p. A.6.2.2","parameters_zh":[{"name":"总热功率","range":"(3 - 50)kW"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877c1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(0 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (0 - 50) kW","reference":"PN-EN 12815:2004 p. A.6.2.3","norm_bases":["PN-EN 12815:2004 p. A.6.2.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE moc cieplna obiegu wodnego (0 - 50) kW PN-EN 12815:2004 p. A.6.2.3 KUCHNIE NA PALIWA STALE moc cieplna obiegu wodnego (0 - 50) kW PN-EN 12815:2004 p. A.6.2.3","categories":["petro"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(0 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output of the water circuit PN-EN 12815:2004 p. A.6.2.3","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水循环回路热功率 PN-EN 12815:2004 p. A.6.2.3","test_object_zh":"固体燃料炊具","parameters_zh":[{"name":"水循环回路热功率","range":"(0 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a4877c2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 - 50) kW","reference":"PN-EN 12815:2004 p. A.6.2.4","norm_bases":["PN-EN 12815:2004 p. A.6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE moc cieplna oddawana do pomieszczenia (3 - 50) kW PN-EN 12815:2004 p. A.6.2.4 KUCHNIE NA PALIWA STALE moc cieplna oddawana do pomieszczenia (3 - 50) kW PN-EN 12815:2004 p. A.6.2.4","categories":["petro"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(3 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 12815:2004 p. A.6.2.4","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 12815:2004 p. A.6.2.4","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 - 50) kW"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877c3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4) %","reference":"PN-EN 12815:2004 p. A.6.2.6","norm_bases":["PN-EN 12815:2004 p. A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE zawartość CO (O2=13%) (0 - 4) % PN-EN 12815:2004 p. A.6.2.6 KUCHNIE NA PALIWA STALE zawartosc CO (O2=13%) (0 - 4) % PN-EN 12815:2004 p. A.6.2.6","categories":["petro"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 12815:2004 p. A.6.2.6","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 12815:2004 p. A.6.2.6","test_object_zh":"固体燃料炊具","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4) %"}]},{"_id":"6a7d7477ec6a53014a4877c4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE","reference":"PN-EN 12815:2004 p. A.6.2.6","norm_bases":["PN-EN 12815:2004 p. A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE PARAMETRY TECHNICZNO - EKSPLOATACYJNE PN-EN 12815:2004 p. A.6.2.6 KUCHNIE NA PALIWA STALE PARAMETRY TECHNICZNO - EKSPLOATACYJNE PN-EN 12815:2004 p. A.6.2.6","categories":["petro"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS TECHNICAL AND OPERATIONAL PARAMETERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12815:2004 p. A.6.2.6","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12815:2004 p. A.6.2.6","test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877c5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200)°C"},{"name":"temperatura uchwytów","range":"(0 - 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200)°C\ntemperatura uchwytów (0 - 200) °C","reference":"PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16","norm_bases":["PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200)°C\ntemperatura uchwytów (0 - 200) °C PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16 KUCHNIE NA PALIWA STALE Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200)°C\ntemperatura uchwytow (0 - 200) °C PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16","categories":["petro"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 - 200)°C"},{"name":"temperature of handles","range":"(0 - 200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) °C"},{"name":"燃料储斗温度","range":"(0 - 200)°C"},{"name":"手柄温度","range":"(0 - 200) °C"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877c6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 12815:2004 p. A.4.17","norm_bases":["PN-EN 12815:2004 p. A.4.17"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 12815:2004 p. A.4.17 KUCHNIE NA PALIWA STALE szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 12815:2004 p. A.4.17","categories":["petro"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness of the water space PN-EN 12815:2004 p. A.4.17","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水腔密封性 PN-EN 12815:2004 p. A.4.17","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877c7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) °C"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) °C\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 12815:2004 p. A.4.18","norm_bases":["PN-EN 12815:2004 p. A.4.18"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) °C\nciśnienie wody (0,1 - 0,3) MPa PN-EN 12815:2004 p. A.4.18 KUCHNIE NA PALIWA STALE Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) °C\ncisnienie wody (0,1 - 0,3) MPa PN-EN 12815:2004 p. A.4.18","categories":["water","petro"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) °C"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 12815:2004 p. A.4.18","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 12815:2004 p. A.4.18","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) °C"},{"name":"水压","range":"(0,1 - 0,3) MPa"}],"test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877c8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"gotowanie, temperatura wody","range":"(0 - 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"gotowanie, temperatura wody (0 - 100) °C","reference":"PN-EN 12815:2004 p. A.4.10","norm_bases":["PN-EN 12815:2004 p. A.4.10"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE gotowanie, temperatura wody (0 - 100) °C PN-EN 12815:2004 p. A.4.10 KUCHNIE NA PALIWA STALE gotowanie, temperatura wody (0 - 100) °C PN-EN 12815:2004 p. A.4.10","categories":["water","petro"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"boiling, water temperature","range":"(0 - 100) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC boiling, water temperature PN-EN 12815:2004 p. A.4.10","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12815:2004 p. A.4.10","test_object_zh":"固体燃料炊具"},{"_id":"6a7d7477ec6a53014a4877c9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KUCHNIE NA PALIWA STAŁE","methodology":"","parameters":[{"name":"pieczenie, temperatura powietrza","range":"(0 - 300) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"pieczenie, temperatura powietrza (0 - 300) °C","reference":"PN-EN 12815:2004 p. A.4.11","norm_bases":["PN-EN 12815:2004 p. A.4.11"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KUCHNIE NA PALIWA STAŁE pieczenie, temperatura powietrza (0 - 300) °C PN-EN 12815:2004 p. A.4.11 KUCHNIE NA PALIWA STALE pieczenie, temperatura powietrza (0 - 300) °C PN-EN 12815:2004 p. A.4.11","categories":["petro"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"baking, air temperature","range":"(0 - 300) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC baking, air temperature PN-EN 12815:2004 p. A.4.11","test_object_en":"SOLID FUEL COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 烘烤、空气温度 PN-EN 12815:2004 p. A.4.11","test_object_zh":"固体燃料炊具","parameters_zh":[{"name":"烘烤、空气温度","range":"(0 - 300) °C"}]},{"_id":"6a7d7477ec6a53014a4877ca","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 12815:2004 p. A.4.11","norm_bases":["PN-EN 12815:2004 p. A.4.11"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY PALIWA: PN-EN 12815:2004 p. A.4.11 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY PALIWA: PN-EN 12815:2004 p. A.4.11","categories":["petro"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12815:2004 p. A.4.11","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 燃料参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12815:2004 p. A.4.11","methodology_zh":"燃料参数：","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877cb","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"(10 - 50) %"},{"name":"wartość opałowa (10 - 32) MJ/kg (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg (z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg (z obliczeń) Procedura nr LGP/42/B wyd. 4 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Zakres:\nzawartosc wilgoci w drewnie (10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg (z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"(10 - 50) %"},{"name":"net calorific value (10 - 32) MJ/kg (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (10 - 32) MJ/kg (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 (10 - 32) MJ/kg（由计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉","parameters_zh":[{"name":"木材含水率","range":"(10 - 50) %"},{"name":"低位发热量 (10 - 32) MJ/kg（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a4877cc","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 12809:2002 p. A3.","norm_bases":["PN-EN 12809:2002 p. A3."],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW masa paliwa (0,1 - 300) kg PN-EN 12809:2002 p. A3. KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW masa paliwa (0,1 - 300) kg PN-EN 12809:2002 p. A3.","categories":["petro"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 12809:2002 p. A3.","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 12809:2002 p. A3.","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877cd","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 12809:2002 p. A3.","norm_bases":["PN-EN 12809:2002 p. A3."],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY SPALIN: PN-EN 12809:2002 p. A3. KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY SPALIN: PN-EN 12809:2002 p. A3.","categories":["petro"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12809:2002 p. A3.","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12809:2002 p. A3.","methodology_zh":"烟气参数：","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877ce","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"temperatura","range":"(0 - 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 - 600) °C","reference":"PN-EN 12809:2002 p. A.2.3.2","norm_bases":["PN-EN 12809:2002 p. A.2.3.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW temperatura (0 - 600) °C PN-EN 12809:2002 p. A.2.3.2 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW temperatura (0 - 600) °C PN-EN 12809:2002 p. A.2.3.2","categories":["petro"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(0 - 600) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 12809:2002 p. A.2.3.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 12809:2002 p. A.2.3.2","parameters_zh":[{"name":"温度","range":"(0 - 600) °C"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877cf","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 12809:2002 p. A.2.3.4; A4","norm_bases":["PN-EN 12809:2002 p. A.2.3.4; A4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW ciśnienie (-10 - 10) hPa PN-EN 12809:2002 p. A.2.3.4; A4 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW cisnienie (-10 - 10) hPa PN-EN 12809:2002 p. A.2.3.4; A4","categories":["petro"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 12809:2002 p. A.2.3.4; A4","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 12809:2002 p. A.2.3.4; A4","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877d0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 12809:2002 p. A.2.3.3","norm_bases":["PN-EN 12809:2002 p. A.2.3.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 12809:2002 p. A.2.3.3 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 12809:2002 p. A.2.3.3","categories":["petro"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO2; CO; PN-EN 12809:2002 p. A.2.3.3","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12809:2002 p. A.2.3.3","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a4877d1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","categories":["environment","petro"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC NO OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC NO 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","parameters_zh":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉","technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a4877d2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,005 - 1) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,005 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Stężenie pyłów w spalinach\nZakres (0,005 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Stezenie pylow w spalinach\nZakres (0,005 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,005 - 1) g/m3"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Dust concentration in flue gases Gravimetric method Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Range PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_en":"Gravimetric method","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"范围","range":"(0,005 - 1) g/m3"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 烟气中粉尘浓度 重量法 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 范围 PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_zh":"重量法","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉","methodology_zh":"烟气中粉尘浓度"},{"_id":"6a7d7477ec6a53014a4877d3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 空气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","methodology_zh":"空气参数：","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877d4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) °C","reference":"PN-EN 12809:2002 p. A.1.1.","norm_bases":["PN-EN 12809:2002 p. A.1.1."],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW temperatura (10 - 35) °C PN-EN 12809:2002 p. A.1.1. KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW temperatura (10 - 35) °C PN-EN 12809:2002 p. A.1.1.","categories":["petro"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 12809:2002 p. A.1.1.","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 12809:2002 p. A.1.1.","parameters_zh":[{"name":"温度","range":"(10 - 35) °C"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877d5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 12809:2002 p. A.1.1.","norm_bases":["PN-EN 12809:2002 p. A.1.1."],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY WODY: PN-EN 12809:2002 p. A.1.1. KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY WODY: PN-EN 12809:2002 p. A.1.1.","categories":["water","petro"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12809:2002 p. A.1.1.","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12809:2002 p. A.1.1.","methodology_zh":"水参数：","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877d6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 100)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 100)°C","reference":"PN-EN 12809:2002 p. A.2.5","norm_bases":["PN-EN 12809:2002 p. A.2.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW temperatura (10 - 100)°C PN-EN 12809:2002 p. A.2.5 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW temperatura (10 - 100)°C PN-EN 12809:2002 p. A.2.5","categories":["petro"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 100)°C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 12809:2002 p. A.2.5","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 12809:2002 p. A.2.5","parameters_zh":[{"name":"温度","range":"(10 - 100)°C"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877d7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 12809:2002 p. A.2.5.","norm_bases":["PN-EN 12809:2002 p. A.2.5."],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW strumień objętości (0 - 3) m3/h PN-EN 12809:2002 p. A.2.5. KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW strumien objetosci (0 - 3) m3/h PN-EN 12809:2002 p. A.2.5.","categories":["petro"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 12809:2002 p. A.2.5.","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 12809:2002 p. A.2.5.","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a4877d8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 12809:2002 p. A.2.5.","norm_bases":["PN-EN 12809:2002 p. A.2.5."],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW BILANS CIEPLNY (z obliczeń): PN-EN 12809:2002 p. A.2.5. KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW BILANS CIEPLNY (z obliczen): PN-EN 12809:2002 p. A.2.5.","categories":["petro"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12809:2002 p. A.2.5.","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12809:2002 p. A.2.5.","methodology_zh":"热平衡（计算值）：","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877d9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(5 - 100) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (5 - 100) kW","reference":"PN-EN 12809:2002 p. A.6.2.2","norm_bases":["PN-EN 12809:2002 p. A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW moc cieplna doprowadzona z paliwem (5 - 100) kW PN-EN 12809:2002 p. A.6.2.2 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW moc cieplna doprowadzona z paliwem (5 - 100) kW PN-EN 12809:2002 p. A.6.2.2","categories":["petro"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(5 - 100) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 12809:2002 p. A.6.2.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 12809:2002 p. A.6.2.2","parameters_zh":[{"name":"燃料输入热功率","range":"(5 - 100) kW"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877da","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 12809:2002 p. A.6.2.1.1","norm_bases":["PN-EN 12809:2002 p. A.6.2.1.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW strata kominowa (5 - 40) % PN-EN 12809:2002 p. A.6.2.1.1 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW strata kominowa (5 - 40) % PN-EN 12809:2002 p. A.6.2.1.1","categories":["petro"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 12809:2002 p. A.6.2.1.1","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 12809:2002 p. A.6.2.1.1","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877db","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 12809:2002 p. A.6.2.1.2","norm_bases":["PN-EN 12809:2002 p. A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW straty niezupełnego spalania PN-EN 12809:2002 p. A.6.2.1.2 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW straty niezupelnego spalania PN-EN 12809:2002 p. A.6.2.1.2","categories":["petro"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 12809:2002 p. A.6.2.1.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 12809:2002 p. A.6.2.1.2","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877dc","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 12809:2002 p. A.6.2.1.3","norm_bases":["PN-EN 12809:2002 p. A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW strata niecałkowitego spalania PN-EN 12809:2002 p. A.6.2.1.3 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW strata niecalkowitego spalania PN-EN 12809:2002 p. A.6.2.1.3","categories":["petro"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 12809:2002 p. A.6.2.1.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 12809:2002 p. A.6.2.1.3","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877dd","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 12809:2002 p. A.6.2.1","norm_bases":["PN-EN 12809:2002 p. A.6.2.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW sprawność cieplna (20 - 95) % PN-EN 12809:2002 p. A.6.2.1 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW sprawnosc cieplna (20 - 95) % PN-EN 12809:2002 p. A.6.2.1","categories":["petro"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal efficiency PN-EN 12809:2002 p. A.6.2.1","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 热效率 PN-EN 12809:2002 p. A.6.2.1","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877de","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(5 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (5 - 50) kW","reference":"PN-EN 12809:2002 p. A.6.2.2","norm_bases":["PN-EN 12809:2002 p. A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW łączna moc cieplna (5 - 50) kW PN-EN 12809:2002 p. A.6.2.2 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW laczna moc cieplna (5 - 50) kW PN-EN 12809:2002 p. A.6.2.2","categories":["petro"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(5 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC total heat output PN-EN 12809:2002 p. A.6.2.2","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 总热功率 PN-EN 12809:2002 p. A.6.2.2","parameters_zh":[{"name":"总热功率","range":"(5 - 50) kW"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877df","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"moc cieplna biegu wodnego","range":"(5 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna biegu wodnego (5 - 50) kW","reference":"PN-EN 12809:2002 p. A.6.2.3.","norm_bases":["PN-EN 12809:2002 p. A.6.2.3."],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW moc cieplna biegu wodnego (5 - 50) kW PN-EN 12809:2002 p. A.6.2.3. KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW moc cieplna biegu wodnego (5 - 50) kW PN-EN 12809:2002 p. A.6.2.3.","categories":["petro"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(5 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output of the water circuit PN-EN 12809:2002 p. A.6.2.3.","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12809:2002 p. A.6.2.3.","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877e0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(5 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (5 - 50) kW","reference":"PN-EN 12809:2002 p. A.6.2.4","norm_bases":["PN-EN 12809:2002 p. A.6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW moc cieplna oddawana do pomieszczenia (5 - 50) kW PN-EN 12809:2002 p. A.6.2.4 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW moc cieplna oddawana do pomieszczenia (5 - 50) kW PN-EN 12809:2002 p. A.6.2.4","categories":["petro"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(5 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 12809:2002 p. A.6.2.4","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 12809:2002 p. A.6.2.4","parameters_zh":[{"name":"向房间输出的热功率","range":"(5 - 50) kW"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877e1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4) %","reference":"PN-EN 12809:2002 p. A.6.2.6","norm_bases":["PN-EN 12809:2002 p. A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW zawartość CO (O2=13%) (0 - 4) % PN-EN 12809:2002 p. A.6.2.6 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW zawartosc CO (O2=13%) (0 - 4) % PN-EN 12809:2002 p. A.6.2.6","categories":["petro"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 12809:2002 p. A.6.2.6","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 12809:2002 p. A.6.2.6","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4) %"}]},{"_id":"6a7d7477ec6a53014a4877e2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 12809:2002 p. A.6.2.6","norm_bases":["PN-EN 12809:2002 p. A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 12809:2002 p. A.6.2.6 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 12809:2002 p. A.6.2.6","categories":["petro"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12809:2002 p. A.6.2.6","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 技术与运行参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12809:2002 p. A.6.2.6","test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉","methodology_zh":"技术与运行参数："},{"_id":"6a7d7477ec6a53014a4877e3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200) °C"},{"name":"temperatura uchwytów","range":"(0 - 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C\ntemperatura uchwytów (0 - 200) °C","reference":"PN-EN 12809:2002 p. A.2; A.3","norm_bases":["PN-EN 12809:2002 p. A.2; A.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C\ntemperatura uchwytów (0 - 200) °C PN-EN 12809:2002 p. A.2; A.3 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C\ntemperatura uchwytow (0 - 200) °C PN-EN 12809:2002 p. A.2; A.3","categories":["petro"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 - 200) °C"},{"name":"temperature of handles","range":"(0 - 200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 12809:2002 p. A.2; A.3","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 12809:2002 p. A.2; A.3","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) °C"},{"name":"燃料储斗温度","range":"(0 - 200) °C"},{"name":"手柄温度","range":"(0 - 200) °C"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877e4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 12809:2002 p. A.4.10","norm_bases":["PN-EN 12809:2002 p. A.4.10"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 12809:2002 p. A.4.10 KOTLY GRZEWCZE NA PALIWA STALE O NOMINALNEJ MOCY GRZEWCZEJ DO 50 kW szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 12809:2002 p. A.4.10","categories":["petro"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness of the water space PN-EN 12809:2002 p. A.4.10","test_object_en":"HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水腔密封性 PN-EN 12809:2002 p. A.4.10","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}],"test_object_zh":"额定热输出 50 kW 以下的固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a4877e5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 12809:2002 p. A.4.10","norm_bases":["PN-EN 12809:2002 p. A.4.10"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE PARAMETRY PALIWA: PN-EN 12809:2002 p. A.4.10 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE PARAMETRY PALIWA: PN-EN 12809:2002 p. A.4.10","categories":["petro"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 12809:2002 p. A.4.10","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 燃料参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 12809:2002 p. A.4.10","methodology_zh":"燃料参数：","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877e6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"( 10 - 50) %"},{"name":"wartość opałowa (10 - 32) MJ/kg (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie ( 10 - 50) %\nwartość opałowa (10 - 32) MJ/kg (z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Zakres:\nzawartość wilgoci w drewnie ( 10 - 50) %\nwartość opałowa (10 - 32) MJ/kg (z obliczeń) Procedura nr LGP/42/B wyd. 4 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE Zakres:\nzawartosc wilgoci w drewnie ( 10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg (z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"( 10 - 50) %"},{"name":"net calorific value (10 - 32) MJ/kg (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (10 - 32) MJ/kg (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 (10 - 32) MJ/kg（由计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"固体燃料蓄热式房间加热器","parameters_zh":[{"name":"木材含水率","range":"( 10 - 50) %"},{"name":"低位发热量 (10 - 32) MJ/kg（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a4877e7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 15250:2009 A3; A4.2","norm_bases":["PN-EN 15250:2009 A3; A4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE masa paliwa (0,1 - 300) kg PN-EN 15250:2009 A3; A4.2 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE masa paliwa (0,1 - 300) kg PN-EN 15250:2009 A3; A4.2","categories":["petro"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 15250:2009 A3; A4.2","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 15250:2009 A3; A4.2","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877e8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 15250:2009 A3; A4.2","norm_bases":["PN-EN 15250:2009 A3; A4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE PARAMETRY SPALIN: PN-EN 15250:2009 A3; A4.2 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE PARAMETRY SPALIN: PN-EN 15250:2009 A3; A4.2","categories":["petro"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 15250:2009 A3; A4.2","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 A3; A4.2","methodology_zh":"烟气参数：","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877e9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(0 - 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 - 600) °C","reference":"PN-EN 15250:2009 p. A2.3.2; A4.4.3","norm_bases":["PN-EN 15250:2009 p. A2.3.2; A4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE temperatura (0 - 600) °C PN-EN 15250:2009 p. A2.3.2; A4.4.3 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE temperatura (0 - 600) °C PN-EN 15250:2009 p. A2.3.2; A4.4.3","categories":["petro"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(0 - 600) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 15250:2009 p. A2.3.2; A4.4.3","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 15250:2009 p. A2.3.2; A4.4.3","parameters_zh":[{"name":"温度","range":"(0 - 600) °C"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877ea","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 15250:2009 p. A2.3.4; A4","norm_bases":["PN-EN 15250:2009 p. A2.3.4; A4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE ciśnienie (-10 - 10) hPa PN-EN 15250:2009 p. A2.3.4; A4 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE cisnienie (-10 - 10) hPa PN-EN 15250:2009 p. A2.3.4; A4","categories":["petro"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 15250:2009 p. A2.3.4; A4","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 15250:2009 p. A2.3.4; A4","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877eb","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15250:2009 p. A2.3.3; A4.4.2","norm_bases":["PN-EN 15250:2009 p. A2.3.3; A4.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15250:2009 p. A2.3.3; A4.4.2 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15250:2009 p. A2.3.3; A4.4.2","categories":["petro"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO2; CO; PN-EN 15250:2009 p. A2.3.3; A4.4.2","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 p. A2.3.3; A4.4.2","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"固体燃料蓄热式房间加热器","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a4877ec","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","categories":["environment","petro"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC NO OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC NO 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","parameters_zh":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"test_object_zh":"固体燃料蓄热式房间加热器","technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a4877ed","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,005 - 1) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,005 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Stężenie pyłów w spalinach\nZakres (0,005 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE Stezenie pylow w spalinach\nZakres (0,005 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,005 - 1) g/m3"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Dust concentration in flue gases Gravimetric method Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Range PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_en":"Gravimetric method","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"范围","range":"(0,005 - 1) g/m3"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 烟气中粉尘浓度 重量法 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 范围 PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_zh":"重量法","test_object_zh":"固体燃料蓄热式房间加热器","methodology_zh":"烟气中粉尘浓度"},{"_id":"6a7d7477ec6a53014a4877ee","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["petro"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 空气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","methodology_zh":"空气参数：","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877ef","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) °C","reference":"PN-EN 15250:2009 p. A1.1; A4.4.3","norm_bases":["PN-EN 15250:2009 p. A1.1; A4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE temperatura (10 - 35) °C PN-EN 15250:2009 p. A1.1; A4.4.3 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE temperatura (10 - 35) °C PN-EN 15250:2009 p. A1.1; A4.4.3","categories":["petro"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 15250:2009 p. A1.1; A4.4.3","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 15250:2009 p. A1.1; A4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) °C"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877f0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 15250:2009 p. A1.1; A4.4.3","norm_bases":["PN-EN 15250:2009 p. A1.1; A4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE BILANS CIEPLNY (z obliczeń): PN-EN 15250:2009 p. A1.1; A4.4.3 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE BILANS CIEPLNY (z obliczen): PN-EN 15250:2009 p. A1.1; A4.4.3","categories":["petro"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 15250:2009 p. A1.1; A4.4.3","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 p. A1.1; A4.4.3","methodology_zh":"热平衡（计算值）：","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877f1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"energia cieplna doprowadzona z paliwem","range":"(10 - 600) MJ"}],"technique":null,"techniques":[],"computed":[],"activity":"energia cieplna doprowadzona z paliwem (10 - 600) MJ","reference":"PN-EN 15250:2009 p. A6.2.2","norm_bases":["PN-EN 15250:2009 p. A6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE energia cieplna doprowadzona z paliwem (10 - 600) MJ PN-EN 15250:2009 p. A6.2.2 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE energia cieplna doprowadzona z paliwem (10 - 600) MJ PN-EN 15250:2009 p. A6.2.2","categories":["petro"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat energy supplied with the fuel","range":"(10 - 600) MJ"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat energy supplied with the fuel PN-EN 15250:2009 p. A6.2.2","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 p. A6.2.2","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877f2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 15250:2009 p. A6.2.1.2","norm_bases":["PN-EN 15250:2009 p. A6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE strata kominowa (5 - 40) % PN-EN 15250:2009 p. A6.2.1.2 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE strata kominowa (5 - 40) % PN-EN 15250:2009 p. A6.2.1.2","categories":["petro"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 15250:2009 p. A6.2.1.2","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 15250:2009 p. A6.2.1.2","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877f3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 15250:2009 p. A6.2.1.3","norm_bases":["PN-EN 15250:2009 p. A6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE straty niezupełnego spalania PN-EN 15250:2009 p. A6.2.1.3 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE straty niezupelnego spalania PN-EN 15250:2009 p. A6.2.1.3","categories":["petro"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 15250:2009 p. A6.2.1.3","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 15250:2009 p. A6.2.1.3","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877f4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 15250:2009 p. A6.2.1.4","norm_bases":["PN-EN 15250:2009 p. A6.2.1.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE strata niecałkowitego spalania PN-EN 15250:2009 p. A6.2.1.4 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE strata niecalkowitego spalania PN-EN 15250:2009 p. A6.2.1.4","categories":["petro"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 15250:2009 p. A6.2.1.4","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 15250:2009 p. A6.2.1.4","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877f5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 15250:2009 p. A6.2.1.1","norm_bases":["PN-EN 15250:2009 p. A6.2.1.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE sprawność cieplna (20 - 95) % PN-EN 15250:2009 p. A6.2.1.1 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE sprawnosc cieplna (20 - 95) % PN-EN 15250:2009 p. A6.2.1.1","categories":["petro"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal efficiency PN-EN 15250:2009 p. A6.2.1.1","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 热效率 PN-EN 15250:2009 p. A6.2.1.1","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877f6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"wydajność cieplna","range":"(10 - 600) MJ"}],"technique":null,"techniques":[],"computed":[],"activity":"wydajność cieplna (10 - 600) MJ","reference":"PN-EN 15250:2009 p. A6.2.2","norm_bases":["PN-EN 15250:2009 p. A6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE wydajność cieplna (10 - 600) MJ PN-EN 15250:2009 p. A6.2.2 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE wydajnosc cieplna (10 - 600) MJ PN-EN 15250:2009 p. A6.2.2","categories":["petro"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output","range":"(10 - 600) MJ"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output PN-EN 15250:2009 p. A6.2.2","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 p. A6.2.2","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877f7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(5 - 100) g/s"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy spalin (5 - 100) g/s","reference":"PN-EN 15250:2009 p. A6.2.3","norm_bases":["PN-EN 15250:2009 p. A6.2.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE strumień masy spalin (5 - 100) g/s PN-EN 15250:2009 p. A6.2.3 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE strumien masy spalin (5 - 100) g/s PN-EN 15250:2009 p. A6.2.3","categories":["petro"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"flue gas mass flow","range":"(5 - 100) g/s"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC flue gas mass flow PN-EN 15250:2009 p. A6.2.3","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 烟气质量流量 PN-EN 15250:2009 p. A6.2.3","test_object_zh":"固体燃料蓄热式房间加热器","parameters_zh":[{"name":"烟气质量流量","range":"(5 - 100) g/s"}]},{"_id":"6a7d7477ec6a53014a4877f8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"zawartość CO","range":"(O2=13%) (0-4)%"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0-4)%","reference":"PN-EN 15250:2009 p. A6.2.4","norm_bases":["PN-EN 15250:2009 p. A6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE zawartość CO (O2=13%) (0-4)% PN-EN 15250:2009 p. A6.2.4 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE zawartosc CO (O2=13%) (0-4)% PN-EN 15250:2009 p. A6.2.4","categories":["petro"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content","range":"(O2=13%) (0-4)%"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content PN-EN 15250:2009 p. A6.2.4","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 p. A6.2.4","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877f9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"średnia różnica temperatury powierzchni ogrzewacza i otoczenia","range":"(0 - 200) K"}],"technique":null,"techniques":[],"computed":[],"activity":"średnia różnica temperatury powierzchni ogrzewacza i otoczenia (0 - 200) K","reference":"PN-EN 15250:2009 p. A6.2.7","norm_bases":["PN-EN 15250:2009 p. A6.2.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE średnia różnica temperatury powierzchni ogrzewacza i otoczenia (0 - 200) K PN-EN 15250:2009 p. A6.2.7 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE srednia roznica temperatury powierzchni ogrzewacza i otoczenia (0 - 200) K PN-EN 15250:2009 p. A6.2.7","categories":["petro"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"mean temperature difference between the heater surface and the surroundings","range":"(0 - 200) K"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC mean temperature difference between the heater surface and the surroundings PN-EN 15250:2009 p. A6.2.7","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 p. A6.2.7","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877fa","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 15250:2009 p. A6.2.7","norm_bases":["PN-EN 15250:2009 p. A6.2.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 15250:2009 p. A6.2.7 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 15250:2009 p. A6.2.7","categories":["petro"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 15250:2009 p. A6.2.7","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 技术与运行参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 p. A6.2.7","test_object_zh":"固体燃料蓄热式房间加热器","methodology_zh":"技术与运行参数："},{"_id":"6a7d7477ec6a53014a4877fb","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura powierzchni akumulacyjnego ogrzewacza","range":"(0 - 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura powierzchni akumulacyjnego ogrzewacza (0 - 200) °C","reference":"PN-EN 15250:2009 p. A2.5; A4.6","norm_bases":["PN-EN 15250:2009 p. A2.5; A4.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE temperatura powierzchni akumulacyjnego ogrzewacza (0 - 200) °C PN-EN 15250:2009 p. A2.5; A4.6 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE temperatura powierzchni akumulacyjnego ogrzewacza (0 - 200) °C PN-EN 15250:2009 p. A2.5; A4.6","categories":["petro"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"surface temperature of the storage heater","range":"(0 - 200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC surface temperature of the storage heater PN-EN 15250:2009 p. A2.5; A4.6","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 p. A2.5; A4.6","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877fc","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200) °C"},{"name":"temperatura uchwytów","range":"(0 - 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C\ntemperatura uchwytów (0 - 200) °C","reference":"PN-EN 15250:2009 p. A2.2; A4.6; A4.7","norm_bases":["PN-EN 15250:2009 p. A2.2; A4.6; A4.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"AKUMULACYJNE OGRZEWACZE POMIESZCZEŃ NA PALIWA STAŁE Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C\ntemperatura uchwytów (0 - 200) °C PN-EN 15250:2009 p. A2.2; A4.6; A4.7 AKUMULACYJNE OGRZEWACZE POMIESZCZEN NA PALIWA STALE Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C\ntemperatura uchwytow (0 - 200) °C PN-EN 15250:2009 p. A2.2; A4.6; A4.7","categories":["petro"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 - 200) °C"},{"name":"temperature of handles","range":"(0 - 200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 15250:2009 p. A2.2; A4.6; A4.7","test_object_en":"SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料蓄热式房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 15250:2009 p. A2.2; A4.6; A4.7","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) °C"},{"name":"燃料储斗温度","range":"(0 - 200) °C"},{"name":"手柄温度","range":"(0 - 200) °C"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d7477ec6a53014a4877fd","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 15250:2009 p. A2.2; A4.6; A4.7","norm_bases":["PN-EN 15250:2009 p. A2.2; A4.6; A4.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI PARAMETRY PALIWA: PN-EN 15250:2009 p. A2.2; A4.6; A4.7 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI PARAMETRY PALIWA: PN-EN 15250:2009 p. A2.2; A4.6; A4.7","categories":["petro"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 15250:2009 p. A2.2; A4.6; A4.7","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 燃料参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 15250:2009 p. A2.2; A4.6; A4.7","test_object_zh":"颗粒燃料房间加热器","methodology_zh":"燃料参数："},{"_id":"6a7d7477ec6a53014a4877fe","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"(0 - 50) %"},{"name":"wartość opałowa","range":"(10 - 32) MJ/kg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie (0 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI Zakres:\nzawartość wilgoci w drewnie (0 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń) Procedura nr LGP/42/B wyd. 4 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI Zakres:\nzawartosc wilgoci w drewnie (0 - 50) %\nwartosc opalowa (10 - 32) MJ/kg\n(z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["other"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"(0 - 50) %"},{"name":"net calorific value","range":"(10 - 32) MJ/kg"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"木材含水率","range":"(0 - 50) %"},{"name":"低位发热量","range":"(10 - 32) MJ/kg"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 （计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"颗粒燃料房间加热器"},{"_id":"6a7d7477ec6a53014a4877ff","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 14785:2009 p. A3; A 4.2","norm_bases":["PN-EN 14785:2009 p. A3; A 4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI masa paliwa (0,1 - 300) kg PN-EN 14785:2009 p. A3; A 4.2 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI masa paliwa (0,1 - 300) kg PN-EN 14785:2009 p. A3; A 4.2","categories":["petro"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 14785:2009 p. A3; A 4.2","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 14785:2009 p. A3; A 4.2","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}]},{"_id":"6a7d7477ec6a53014a487800","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"-pobieranie i przygotowanie próbek do analiz","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"-pobieranie i przygotowanie próbek do analiz","reference":"Procedura LGP/42/B","norm_bases":["Procedura LGP/42/B"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI -pobieranie i przygotowanie próbek do analiz Procedura LGP/42/B OGRZEWACZE POMIESZCZEN OPALANE PELETAMI -pobieranie i przygotowanie probek do analiz Procedura LGP/42/B","categories":["other"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"-sampling and preparation of samples for analysis","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS -sampling and preparation of samples for analysis Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Procedura LGP/42/B","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC Procedura LGP/42/B","test_object_zh":"颗粒燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487801","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"Procedura LGP/42/B","norm_bases":["Procedura LGP/42/B"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI PARAMETRY SPALIN: Procedura LGP/42/B OGRZEWACZE POMIESZCZEN OPALANE PELETAMI PARAMETRY SPALIN: Procedura LGP/42/B","categories":["other"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Procedura LGP/42/B","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC Procedura LGP/42/B","test_object_zh":"颗粒燃料房间加热器","methodology_zh":"烟气参数："},{"_id":"6a7d7477ec6a53014a487802","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"temperatura","range":"(0 - 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 - 600) °C","reference":"PN-EN 14785:2009 p. A2.3.2; A4.4.3","norm_bases":["PN-EN 14785:2009 p. A2.3.2; A4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI temperatura (0 - 600) °C PN-EN 14785:2009 p. A2.3.2; A4.4.3 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI temperatura (0 - 600) °C PN-EN 14785:2009 p. A2.3.2; A4.4.3","categories":["other"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(0 - 600) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 14785:2009 p. A2.3.2; A4.4.3","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 14785:2009 p. A2.3.2; A4.4.3","parameters_zh":[{"name":"温度","range":"(0 - 600) °C"}],"test_object_zh":"颗粒燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487803","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 14785:2009 p. A2.3.4; A4","norm_bases":["PN-EN 14785:2009 p. A2.3.4; A4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI ciśnienie (-10 - 10) hPa PN-EN 14785:2009 p. A2.3.4; A4 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI cisnienie (-10 - 10) hPa PN-EN 14785:2009 p. A2.3.4; A4","categories":["other"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 14785:2009 p. A2.3.4; A4","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 14785:2009 p. A2.3.4; A4","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"颗粒燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487804","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2;","range":"(0,5-16) %"},{"name":"CO;","range":"(0,0003-4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5-16) %\nCO; (0,0003-4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 14785:2009 p. A2.3.3; 4.4.2","norm_bases":["PN-EN 14785:2009 p. A2.3.3; 4.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5-16) %\nCO; (0,0003-4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 14785:2009 p. A2.3.3; 4.4.2 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2; (0,5-16) %\nCO; (0,0003-4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 14785:2009 p. A2.3.3; 4.4.2","categories":["other"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2;","range":"(0,5-16) %"},{"name":"CO;","range":"(0,0003-4,0) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO2; CO; PN-EN 14785:2009 p. A2.3.3; 4.4.2","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 14785:2009 p. A2.3.3; 4.4.2","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"颗粒燃料房间加热器","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a487805","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","categories":["environment"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC NO OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC NO 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8","parameters_zh":[{"name":"NO","range":"(5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"test_object_zh":"颗粒燃料房间加热器","technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a487806","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,002 - 1) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI Stężenie pyłów w spalinach\nZakres (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI Stezenie pylow w spalinach\nZakres (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["other"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,002 - 1) g/m3"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Dust concentration in flue gases Gravimetric method Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Range PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_en":"Gravimetric method","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"范围","range":"(0,002 - 1) g/m3"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 烟气中粉尘浓度 重量法 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 范围 PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","technique_zh":"重量法","test_object_zh":"颗粒燃料房间加热器","methodology_zh":"烟气中粉尘浓度"},{"_id":"6a7d7477ec6a53014a487807","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","norm_bases":["PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8","PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI PARAMETRY POWIETRZA: PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","categories":["other"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 空气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8","test_object_zh":"颗粒燃料房间加热器","methodology_zh":"空气参数："},{"_id":"6a7d7477ec6a53014a487808","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) °C","reference":"PN-EN 14785:2009 p. A1.1; A4.4.3","norm_bases":["PN-EN 14785:2009 p. A1.1; A4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI temperatura (10 - 35) °C PN-EN 14785:2009 p. A1.1; A4.4.3 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI temperatura (10 - 35) °C PN-EN 14785:2009 p. A1.1; A4.4.3","categories":["other"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 14785:2009 p. A1.1; A4.4.3","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 14785:2009 p. A1.1; A4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) °C"}],"test_object_zh":"颗粒燃料房间加热器"},{"_id":"6a7d7477ec6a53014a487809","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 14785:2009 p. A1.1; A4.4.3","norm_bases":["PN-EN 14785:2009 p. A1.1; A4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI PARAMETRY WODY: PN-EN 14785:2009 p. A1.1; A4.4.3 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI PARAMETRY WODY: PN-EN 14785:2009 p. A1.1; A4.4.3","categories":["water"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 14785:2009 p. A1.1; A4.4.3","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 14785:2009 p. A1.1; A4.4.3","test_object_zh":"颗粒燃料房间加热器","methodology_zh":"水参数："},{"_id":"6a7d7477ec6a53014a48780a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 100) °C","reference":"PN-EN 14785:2009 p. A2.5; A4.5","norm_bases":["PN-EN 14785:2009 p. A2.5; A4.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI temperatura (10 - 100) °C PN-EN 14785:2009 p. A2.5; A4.5 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI temperatura (10 - 100) °C PN-EN 14785:2009 p. A2.5; A4.5","categories":["other"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 100) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 14785:2009 p. A2.5; A4.5","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 14785:2009 p. A2.5; A4.5","parameters_zh":[{"name":"温度","range":"(10 - 100) °C"}],"test_object_zh":"颗粒燃料房间加热器"},{"_id":"6a7d7477ec6a53014a48780b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 14785:2009 p. A2.5; A4.5","norm_bases":["PN-EN 14785:2009 p. A2.5; A4.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI strumień objętości (0 - 3) m3/h PN-EN 14785:2009 p. A2.5; A4.5 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI strumien objetosci (0 - 3) m3/h PN-EN 14785:2009 p. A2.5; A4.5","categories":["other"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 14785:2009 p. A2.5; A4.5","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 14785:2009 p. A2.5; A4.5","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a48780c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 14785:2009 p. A2.5; A4.5","norm_bases":["PN-EN 14785:2009 p. A2.5; A4.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI BILANS CIEPLNY (z obliczeń): PN-EN 14785:2009 p. A2.5; A4.5 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI BILANS CIEPLNY (z obliczen): PN-EN 14785:2009 p. A2.5; A4.5","categories":["other"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 14785:2009 p. A2.5; A4.5","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 14785:2009 p. A2.5; A4.5","test_object_zh":"颗粒燃料房间加热器","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d7477ec6a53014a48780d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 14785:2009 p. A6.2.2","norm_bases":["PN-EN 14785:2009 p. A6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 14785:2009 p. A6.2.2 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 14785:2009 p. A6.2.2","categories":["petro"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 14785:2009 p. A6.2.2","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 14785:2009 p. A6.2.2","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}]},{"_id":"6a7d7477ec6a53014a48780e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 14785:2009 p. A6.2.1.1","norm_bases":["PN-EN 14785:2009 p. A6.2.1.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI strata kominowa (5 - 40) % PN-EN 14785:2009 p. A6.2.1.1 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI strata kominowa (5 - 40) % PN-EN 14785:2009 p. A6.2.1.1","categories":["other"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 14785:2009 p. A6.2.1.1","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 14785:2009 p. A6.2.1.1","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}]},{"_id":"6a7d7477ec6a53014a48780f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 14785:2009 p. A6.2.1.2","norm_bases":["PN-EN 14785:2009 p. A6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI straty niezupełnego spalania PN-EN 14785:2009 p. A6.2.1.2 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI straty niezupelnego spalania PN-EN 14785:2009 p. A6.2.1.2","categories":["other"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 14785:2009 p. A6.2.1.2","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 14785:2009 p. A6.2.1.2","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a487810","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 14785:2009 p. A6.2.1.3","norm_bases":["PN-EN 14785:2009 p. A6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI strata niecałkowitego spalania PN-EN 14785:2009 p. A6.2.1.3 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI strata niecalkowitego spalania PN-EN 14785:2009 p. A6.2.1.3","categories":["other"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 14785:2009 p. A6.2.1.3","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 14785:2009 p. A6.2.1.3","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a487811","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 14785:2009 p. A6.2.1","norm_bases":["PN-EN 14785:2009 p. A6.2.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI sprawność cieplna (20 - 95) % PN-EN 14785:2009 p. A6.2.1 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI sprawnosc cieplna (20 - 95) % PN-EN 14785:2009 p. A6.2.1","categories":["other"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal efficiency PN-EN 14785:2009 p. A6.2.1","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 热效率 PN-EN 14785:2009 p. A6.2.1","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}]},{"_id":"6a7d7477ec6a53014a487812","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 - 50) kW","reference":"PN-EN 14785:2009 p. A6.2.2","norm_bases":["PN-EN 14785:2009 p. A6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI łączna moc cieplna (3 - 50) kW PN-EN 14785:2009 p. A6.2.2 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI laczna moc cieplna (3 - 50) kW PN-EN 14785:2009 p. A6.2.2","categories":["other"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(3 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC total heat output PN-EN 14785:2009 p. A6.2.2","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 总热功率 PN-EN 14785:2009 p. A6.2.2","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"总热功率","range":"(3 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a487813","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(3 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (3 - 50) kW","reference":"PN-EN 14785:2009 p. A6.2.3","norm_bases":["PN-EN 14785:2009 p. A6.2.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI moc cieplna obiegu wodnego (3 - 50) kW PN-EN 14785:2009 p. A6.2.3 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI moc cieplna obiegu wodnego (3 - 50) kW PN-EN 14785:2009 p. A6.2.3","categories":["other"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(3 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output of the water circuit PN-EN 14785:2009 p. A6.2.3","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水循环回路热功率 PN-EN 14785:2009 p. A6.2.3","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"水循环回路热功率","range":"(3 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a487814","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 - 50) kW","reference":"PN-EN 14785:2009 p. A6.2.4","norm_bases":["PN-EN 14785:2009 p. A6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI moc cieplna oddawana do pomieszczenia (3 - 50) kW PN-EN 14785:2009 p. A6.2.4 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI moc cieplna oddawana do pomieszczenia (3 - 50) kW PN-EN 14785:2009 p. A6.2.4","categories":["other"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(3 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 14785:2009 p. A6.2.4","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 14785:2009 p. A6.2.4","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a487815","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(5 - 100) g/s"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy spalin (5 - 100) g/s","reference":"PN-EN 14785:2009 p. A6.2.5","norm_bases":["PN-EN 14785:2009 p. A6.2.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI strumień masy spalin (5 - 100) g/s PN-EN 14785:2009 p. A6.2.5 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI strumien masy spalin (5 - 100) g/s PN-EN 14785:2009 p. A6.2.5","categories":["other"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"flue gas mass flow","range":"(5 - 100) g/s"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC flue gas mass flow PN-EN 14785:2009 p. A6.2.5","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 烟气质量流量 PN-EN 14785:2009 p. A6.2.5","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"烟气质量流量","range":"(5 - 100) g/s"}]},{"_id":"6a7d7477ec6a53014a487816","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4)%"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4)%","reference":"PN-EN 14785:2009 p. A6.2.6","norm_bases":["PN-EN 14785:2009 p. A6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI zawartość CO (O2=13%) (0 - 4)% PN-EN 14785:2009 p. A6.2.6 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI zawartosc CO (O2=13%) (0 - 4)% PN-EN 14785:2009 p. A6.2.6","categories":["other"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4)%"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 14785:2009 p. A6.2.6","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 14785:2009 p. A6.2.6","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4)%"}]},{"_id":"6a7d7477ec6a53014a487817","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 14785:2009 p. A6.2.6","norm_bases":["PN-EN 14785:2009 p. A6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 14785:2009 p. A6.2.6 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 14785:2009 p. A6.2.6","categories":["other"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 14785:2009 p. A6.2.6","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 技术与运行参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 14785:2009 p. A6.2.6","test_object_zh":"颗粒燃料房间加热器","methodology_zh":"技术与运行参数："},{"_id":"6a7d7477ec6a53014a487818","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C","reference":"PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9","norm_bases":["PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) °C\ntemperatura zasobnika paliwa (0 - 200) °C PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9","categories":["petro"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 - 200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature of the measuring corner and the floor temperature of the fuel hopper PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 测量角与地面的温度 燃料储斗温度 PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) °C"},{"name":"燃料储斗温度","range":"(0 - 200) °C"}]},{"_id":"6a7d7477ec6a53014a487819","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"temperatura uchwytów","range":"(0 - 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura uchwytów (0 - 200) °C","reference":"PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9","norm_bases":["PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI temperatura uchwytów (0 - 200) °C PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI temperatura uchwytow (0 - 200) °C PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9","categories":["other"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of handles","range":"(0 - 200) °C"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature of handles PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 手柄温度 PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"手柄温度","range":"(0 - 200) °C"}]},{"_id":"6a7d7477ec6a53014a48781a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 14785:2009 p. A4.9.2","norm_bases":["PN-EN 14785:2009 p. A4.9.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 14785:2009 p. A4.9.2 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 14785:2009 p. A4.9.2","categories":["other"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness of the water space PN-EN 14785:2009 p. A4.9.2","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水腔密封性 PN-EN 14785:2009 p. A4.9.2","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}]},{"_id":"6a7d7477ec6a53014a48781b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) °C"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) °C\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 14785:2009 p. A4.9.3","norm_bases":["PN-EN 14785:2009 p. A4.9.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"OGRZEWACZE POMIESZCZEŃ OPALANE PELETAMI Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) °C\nciśnienie wody (0,1 - 0,3) MPa PN-EN 14785:2009 p. A4.9.3 OGRZEWACZE POMIESZCZEN OPALANE PELETAMI Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) °C\ncisnienie wody (0,1 - 0,3) MPa PN-EN 14785:2009 p. A4.9.3","categories":["water"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) °C"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"PELLET-FIRED LOCAL SPACE HEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 14785:2009 p. A4.9.3","test_object_en":"PELLET-FIRED LOCAL SPACE HEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"颗粒燃料房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 14785:2009 p. A4.9.3","test_object_zh":"颗粒燃料房间加热器","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) °C"},{"name":"水压","range":"(0,1 - 0,3) MPa"}]},{"_id":"6a7d7477ec6a53014a48781c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"KOTŁY GRZEWCZE NA PALIWA STAŁE","methodology":"Pomiar zużycia energii elektrycznej","parameters":[{"name":"Zakres","range":"(2 - 4000) W"}],"technique":"Metoda: przetworników mocy","techniques":["Metoda: przetworników mocy"],"computed":[],"activity":"Pomiar zużycia energii elektrycznej\nZakres (2 - 4000) W\nMetoda: przetworników mocy","reference":"PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7","norm_bases":["PN-EN 303-5:2021-09 p. 5.7.7","PN-EN 303-5+A1:2023-05 p. 5.7.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"KOTŁY GRZEWCZE NA PALIWA STAŁE Pomiar zużycia energii elektrycznej\nZakres (2 - 4000) W\nMetoda: przetworników mocy PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7 KOTLY GRZEWCZE NA PALIWA STALE Pomiar zuzycia energii elektrycznej\nZakres (2 - 4000) W\nMetoda: przetwornikow mocy PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7","categories":["petro"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Measurement of electric energy consumption","parameters_en":[{"name":"Range","range":"(2 - 4000) W"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"HEATING BOILERS FOR SOLID FUELS Measurement of electric energy consumption Method: power transducers Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC Range PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7","technique_en":"Method: power transducers","test_object_en":"HEATING BOILERS FOR SOLID FUELS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"范围","range":"(2 - 4000) W"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"固体燃料供暖锅炉 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 范围 PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d7477ec6a53014a48781d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7","norm_bases":["PN-EN 303-5:2021-09 p. 5.7.7","PN-EN 303-5+A1:2023-05 p. 5.7.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE PARAMETRY PALIWA: PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE PARAMETRY PALIWA: PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7","categories":["petro"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 燃料参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"燃料参数："},{"_id":"6a7d7477ec6a53014a48781e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"(10 - 50) %"},{"name":"wartość opałowa","range":"(10 - 32) MJ/kg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń) Procedura nr LGP/42/B wyd. 4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE Zakres:\nzawartosc wilgoci w drewnie (10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg\n(z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"(10 - 50) %"},{"name":"net calorific value","range":"(10 - 32) MJ/kg"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"木材含水率","range":"(10 - 50) %"},{"name":"低位发热量","range":"(10 - 32) MJ/kg"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 （计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d7477ec6a53014a48781f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}]},{"_id":"6a7d7477ec6a53014a487820","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"烟气参数："},{"_id":"6a7d7477ec6a53014a487821","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(15 - 1100) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (15 - 1100) oC","reference":"PN-EN 16510-1:2023-06 A.4.4.3, A.6.2","norm_bases":["PN-EN 16510-1:2023-06 A.4.4.3, A.6.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE temperatura (15 - 1100) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE temperatura (15 - 1100) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2","categories":["petro"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(15 - 1100) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 A.4.4.3, A.6.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 A.4.4.3, A.6.2","parameters_zh":[{"name":"温度","range":"(15 - 1100) oC"}],"test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d7477ec6a53014a487822","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE ciśnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE cisnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4","categories":["petro"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC pressure PN-EN 16510-1:2023-06 p. A.2.3.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 压力 PN-EN 16510-1:2023-06 p. A.2.3.4","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d7477ec6a53014a487823","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3","categories":["petro"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO2; CO; PN-EN 16510-1:2023-06 p. A.4.4.2, A.3","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.2, A.3","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a487824","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E","categories":["petro","environment"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC NO (5 - 440) mg/m3 OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"NO (5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a487825","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"Stężenie pyłów w spalinach (0,002 - 1) g/m3","parameters":[],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE Stezenie pylow w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F","categories":["petro"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases (0,002 - 1) g/m3","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Dust concentration in flue gases (0,002 - 1) g/m3 Gravimetric method Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","technique_en":"Gravimetric method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 烟气中粉尘浓度 (0,002 - 1) g/m3 重量法 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","technique_zh":"重量法","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"烟气中粉尘浓度 (0,002 - 1) g/m3"},{"_id":"6a7d7477ec6a53014a487826","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F","categories":["petro"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 空气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"空气参数："},{"_id":"6a7d7477ec6a53014a487827","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p.A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p.A.4.4.3","categories":["petro"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p.A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p.A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) oC"}],"test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d7477ec6a53014a487828","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p.A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE PARAMETRY WODY: PN-EN 16510-1:2023-06 p.A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE PARAMETRY WODY: PN-EN 16510-1:2023-06 p.A.4.4.3","categories":["petro","water"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p.A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p.A.4.4.3","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"水参数："},{"_id":"6a7d7477ec6a53014a487829","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 100) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 100) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE temperatura (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE temperatura (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 100) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(10 - 100) oC"}],"test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d7477ec6a53014a48782a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE strumień objętości (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE strumien objetosci (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a48782b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d7477ec6a53014a48782c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2","categories":["petro"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}]},{"_id":"6a7d7477ec6a53014a48782d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2","categories":["petro"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}]},{"_id":"6a7d7477ec6a53014a48782e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE straty niezupełnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE straty niezupelnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3","categories":["petro"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a48782f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE strata niecałkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE strata niecalkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4","categories":["petro"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a487830","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE sprawność cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE sprawnosc cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1","categories":["petro"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal efficiency PN-EN 16510-1:2023-06 p.A.6.2.1","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 热效率 PN-EN 16510-1:2023-06 p.A.6.2.1","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}]},{"_id":"6a7d7477ec6a53014a487831","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE łączna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE laczna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2","categories":["petro"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(2 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC total heat output PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 总热功率 PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"总热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a487832","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(1,5 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (1,5 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3","categories":["petro"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(1,5 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output of the water circuit PN-EN 16510-1:2023-06 p.A.6.2.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水循环回路热功率 PN-EN 16510-1:2023-06 p.A.6.2.3","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"水循环回路热功率","range":"(1,5 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a487833","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4","categories":["petro"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(2 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"向房间输出的热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a487834","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE zawartość CO (O2=13%) (0 - 4) % PN-EN 16510-1:2023-06 p.A.6.2.6 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE zawartosc CO (O2=13%) (0 - 4) % PN-EN 16510-1:2023-06 p.A.6.2.6","categories":["petro"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4) %"}]},{"_id":"6a7d7477ec6a53014a487835","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(1-100) g/s"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstrumień masy spalin (1-100) g/s\n(z obliczeń)","reference":"PN-EN 16510-1:2023-06 6.12","norm_bases":["PN-EN 16510-1:2023-06 6.12"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE Zakres:\nstrumień masy spalin (1-100) g/s\n(z obliczeń) PN-EN 16510-1:2023-06 6.12 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE Zakres:\nstrumien masy spalin (1-100) g/s\n(z obliczen) PN-EN 16510-1:2023-06 6.12","categories":["petro"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"flue gas mass flow","range":"(1-100) g/s"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC flue gas mass flow (calculated) PN-EN 16510-1:2023-06 6.12","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"烟气质量流量","range":"(1-100) g/s"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 烟气质量流量 （计算得出） PN-EN 16510-1:2023-06 6.12","test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d7477ec6a53014a487836","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"PARAMETRY TECHNICZNO-EKSPOATACYJNE","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO-EKSPOATACYJNE","reference":"PN-EN 16510-1:2023-06 6.12","norm_bases":["PN-EN 16510-1:2023-06 6.12"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE PARAMETRY TECHNICZNO-EKSPOATACYJNE PN-EN 16510-1:2023-06 6.12 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE PARAMETRY TECHNICZNO-EKSPOATACYJNE PN-EN 16510-1:2023-06 6.12","categories":["petro"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES TECHNICAL AND OPERATIONAL PARAMETERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 6.12","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 6.12","test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d7477ec6a53014a487837","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) oC"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200) oC"},{"name":"temperatura uchwytów","range":"(0 - 200) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6,","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6,"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6, MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytow (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6,","categories":["petro"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) oC"},{"name":"temperature of the fuel hopper","range":"(0 - 200) oC"},{"name":"temperature of handles","range":"(0 - 200) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6,","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6,","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) oC"},{"name":"燃料储斗温度","range":"(0 - 200) oC"},{"name":"手柄温度","range":"(0 - 200) oC"}]},{"_id":"6a7d7477ec6a53014a487838","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6","categories":["petro"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}]},{"_id":"6a7d7477ec6a53014a487839","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"termiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE termiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC PN-EN 16510-1:2023-06 p. A.4.10.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE termiczne zabezpieczenie odplywu temperatura wody (0 - 120) oC PN-EN 16510-1:2023-06 p. A.4.10.7","categories":["petro","water"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) oC"}]},{"_id":"6a7d7477ec6a53014a48783a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE ciśnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE cisnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.7","categories":["petro","water"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC water pressure PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水压 PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"水压","range":"(0,1 - 0,3) MPa"}]},{"_id":"6a7d7477ec6a53014a48783b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"szczelność (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (5 - 75) Pa; (0,2 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE szczelność (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE szczelnosc (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","categories":["petro"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness (5 - 75) Pa; PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 密封性 (5 - 75) Pa； PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"密封性 (5 - 75) Pa；","range":"(0,2 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a48783c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p 5.9.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p 5.9.1 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p 5.9.1","categories":["petro"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p 5.9.1","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p 5.9.1","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a48783d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"stała utrata powietrza","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstała utrata powietrza (1)Pa;\n(0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 Załącznik I","norm_bases":["PN-EN 16510-1:2023-06 Załącznik I"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE Zakres:\nstała utrata powietrza (1)Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE Zakres:\nstala utrata powietrza (1)Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Zalacznik I","categories":["petro"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"constant air loss","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC constant air loss (0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 持续漏气量 PN-EN 16510-1:2023-06 Załącznik I","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"持续漏气量","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a48783e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej (2 - 4000) W, metoda: przetworników mocy"}],"technique":null,"techniques":[],"computed":[],"activity":"pomiar zużycia energii elektrycznej (2 - 4000) W, metoda: przetworników mocy","reference":"PN-EN 16510-1:2023-06 p 6.11","norm_bases":["PN-EN 16510-1:2023-06 p 6.11"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE pomiar zużycia energii elektrycznej (2 - 4000) W, metoda: przetworników mocy PN-EN 16510-1:2023-06 p 6.11 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE pomiar zuzycia energii elektrycznej (2 - 4000) W, metoda: przetwornikow mocy PN-EN 16510-1:2023-06 p 6.11","categories":["petro"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"measurement of electricity consumption (2 - 4000) W, method: power transducers"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC measurement of electricity consumption (2 - 4000) W, method: power transducers PN-EN 16510-1:2023-06 p 6.11","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p 6.11","test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d7477ec6a53014a48783f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4","categories":["petro"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature safety test"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature safety test PN-EN 16510-1:2023-06 p A.4.10.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度安全性试验 PN-EN 16510-1:2023-06 p A.4.10.4","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d7477ec6a53014a487840","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5","categories":["petro"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"safety test under natural draught"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC safety test under natural draught PN-EN 16510-1:2023-06 p A.4.10.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p A.4.10.5","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d7477ec6a53014a487841","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"działanie ogranicznika temperatury bezpieczeństwa","range":"(0 - 110) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"działanie ogranicznika temperatury bezpieczeństwa (0 - 110) oC","reference":"PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7","norm_bases":["PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“","PN-EN 16510-1:2023-06 p A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE działanie ogranicznika temperatury bezpieczeństwa (0 - 110) oC PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE dzialanie ogranicznika temperatury bezpieczenstwa (0 - 110) oC PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7","categories":["petro"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"operation of the safety temperature limiter","range":"(0 - 110) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. operation of the safety temperature limiter PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 安全温度限制器的动作 PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"安全温度限制器的动作","range":"(0 - 110) oC"}]},{"_id":"6a7d7477ec6a53014a487842","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"zanik zasilania elektrycznego","range":"(0 - 110)"},{"name":"oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzanik zasilania elektrycznego (0 - 110)\noC","reference":"PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7","norm_bases":["PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“","PN-EN 16510-1:2023-06 p A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE Zakres:\nzanik zasilania elektrycznego (0 - 110)\noC PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE Zakres:\nzanik zasilania elektrycznego (0 - 110)\noC PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7","categories":["petro"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss of electrical power supply","range":"(0 - 110)"},{"name":"oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. loss of electrical power supply oC PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 供电中断 PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"供电中断","range":"(0 - 110)"},{"name":"oC"}]},{"_id":"6a7d7477ec6a53014a487843","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"zanik odbioru ciepła (0 - 110) oC,","range":"(0 - 5)"},{"name":"% CO"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzanik odbioru ciepła (0 - 110) oC, (0 - 5)\n% CO","reference":"PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7","PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE Zakres:\nzanik odbioru ciepła (0 - 110) oC, (0 - 5)\n% CO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE Zakres:\nzanik odbioru ciepla (0 - 110) oC, (0 - 5)\n% CO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“","categories":["petro"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss of heat removal (0 - 110) oC,","range":"(0 - 5)"},{"name":"% CO"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. loss of heat removal (0 - 110) oC, % CO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 散热中断 (0 - 110) oC， PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"散热中断 (0 - 110) oC，","range":"(0 - 5)"},{"name":"% CO"}]},{"_id":"6a7d7477ec6a53014a487844","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"efektywność (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE efektywność (z obliczeń) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE efektywnosc (z obliczen) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6","categories":["petro"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"efficiency (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC efficiency (calculated) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 效率（由计算得出） PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"效率（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a487845","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6","categories":["petro"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃料参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"燃料参数："},{"_id":"6a7d7477ec6a53014a487846","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"(10 - 50) %"},{"name":"wartość opałowa","range":"(10 - 32) MJ/kg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń) Procedura nr LGP/42/B wyd. 4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Zakres:\nzawartosc wilgoci w drewnie (10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg\n(z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"(10 - 50) %"},{"name":"net calorific value","range":"(10 - 32) MJ/kg"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"木材含水率","range":"(10 - 50) %"},{"name":"低位发热量","range":"(10 - 32) MJ/kg"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 （计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d7477ec6a53014a487847","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}]},{"_id":"6a7d7477ec6a53014a487848","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"烟气参数："},{"_id":"6a7d7477ec6a53014a487849","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"temperatura","range":"(15 - 1100) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (15 - 1100) oC","reference":"PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“","norm_bases":["PN-EN 16510-1:2023-06 A.4.4.3, A.6.2","PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE temperatura (15 - 1100) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE temperatura (15 - 1100) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“","categories":["petro"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(15 - 1100) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“","parameters_zh":[{"name":"温度","range":"(15 - 1100) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d7477ec6a53014a48784a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4","PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE ciśnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE cisnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“","categories":["petro"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d7477ec6a53014a48784b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"Stężenia dwutlenku węgla, tlenku węgla. Zakres:","parameters":[{"name":"CO2; (0,5 - 16) %"},{"name":"CO; (0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla. Zakres:\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3","PN-EN 16510-2-1:2023-06 p. 4.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Stężenia dwutlenku węgla, tlenku węgla. Zakres:\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Stezenia dwutlenku wegla, tlenku wegla. Zakres:\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“","categories":["petro"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide. Range:","parameters_en":[{"name":"CO2; (0,5 - 16) %"},{"name":"CO; (0,0003 - 4,0) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Concentrations of carbon dioxide, carbon monoxide. Range: Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 二氧化碳、一氧化碳浓度。范围： 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"二氧化碳、一氧化碳浓度。范围："},{"_id":"6a7d7477ec6a53014a48784c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"Stężenia tlenku azotu, OGC","parameters":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Stężenia tlenku azotu, OGC\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Stezenia tlenku azotu, OGC\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","categories":["petro","environment"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Nitrogen monoxide, OGC concentrations","parameters_en":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Nitrogen monoxide, OGC concentrations Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO (5 - 440) mg/m3 OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"NO (5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）"},{"_id":"6a7d7477ec6a53014a48784d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"Stężenie pyłów w spalinach (0,002 - 1) g/m3","parameters":[],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-1:2023-06 p. 4.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Stezenie pylow w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“","categories":["petro"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases (0,002 - 1) g/m3","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Dust concentration in flue gases (0,002 - 1) g/m3 Gravimetric method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“","technique_en":"Gravimetric method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 烟气中粉尘浓度 (0,002 - 1) g/m3 重量法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“","technique_zh":"重量法","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"烟气中粉尘浓度 (0,002 - 1) g/m3"},{"_id":"6a7d7477ec6a53014a48784e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-1:2023-06 p. 4.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“","categories":["petro"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 空气参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"空气参数："},{"_id":"6a7d7477ec6a53014a48784f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d7477ec6a53014a487850","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"水参数："},{"_id":"6a7d7477ec6a53014a487851","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 100) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 100) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE temperatura (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE temperatura (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 100) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(10 - 100) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d7477ec6a53014a487852","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE strumień objętości (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE strumien objetosci (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a487853","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d7477ec6a53014a487854","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2","categories":["petro"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}]},{"_id":"6a7d7477ec6a53014a487855","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2","categories":["petro"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}]},{"_id":"6a7d7477ec6a53014a487856","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE straty niezupełnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE straty niezupelnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3","categories":["petro"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a487857","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE strata niecałkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE strata niecalkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4","categories":["petro"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a487858","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1","PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE sprawność cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE sprawnosc cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“","categories":["petro"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}]},{"_id":"6a7d7477ec6a53014a487859","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2","PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE łączna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE laczna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“","categories":["petro"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(2 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. total heat output PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总热功率 PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"总热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a48785a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(1,5 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (1,5 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.3","PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“","categories":["petro"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(1,5 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"水循环回路热功率","range":"(1,5 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a48785b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4","categories":["petro"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(2 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"向房间输出的热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a48785c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4)%"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4)%","reference":"PN-EN 16510-1:2023-06 p.A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE zawartość CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE zawartosc CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6","categories":["petro"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4)%"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4)%"}]},{"_id":"6a7d7477ec6a53014a48785d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(1 - 100) g/s"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń)","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Zakres:\nstrumien masy spalin (1 - 100) g/s\n(z obliczen) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","categories":["petro"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"flue gas mass flow","range":"(1 - 100) g/s"},{"name":"(calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow (calculated) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"烟气质量流量","range":"(1 - 100) g/s"},{"name":"（计算得出）"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 （计算得出） PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d7477ec6a53014a48785e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"PARAMETRY TECHNICZNO-EKSPOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO-EKSPOATACYJNE:","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE PARAMETRY TECHNICZNO-EKSPOATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE PARAMETRY TECHNICZNO-EKSPOATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","categories":["petro"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 技术与运行参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"技术与运行参数："},{"_id":"6a7d7477ec6a53014a48785f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) oC"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200) oC"},{"name":"temperatura uchwytów","range":"(0 - 200) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „ | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „","PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „ | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytow (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „ | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“","categories":["petro"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) oC"},{"name":"temperature of the fuel hopper","range":"(0 - 200) oC"},{"name":"temperature of handles","range":"(0 - 200) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „ | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „ | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) oC"},{"name":"燃料储斗温度","range":"(0 - 200) oC"},{"name":"手柄温度","range":"(0 - 200) oC"}]},{"_id":"6a7d7477ec6a53014a487860","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6","PN-EN 16510-2-1:2023-06 p. 5.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N“","categories":["petro"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}]},{"_id":"6a7d7477ec6a53014a487861","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) oC"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) oC\ncisnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7","categories":["petro","water"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) oC"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p A.4.10.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p A.4.10.7","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) oC"},{"name":"水压","range":"(0,1 - 0,3) MPa"}]},{"_id":"6a7d7477ec6a53014a487862","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"szczelność (5 - 75)Pa;","range":"(0,2 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (5 - 75)Pa; (0,2 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE szczelność (5 - 75)Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE szczelnosc (5 - 75)Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","categories":["petro"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness (5 - 75)Pa;","range":"(0,2 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness (5 - 75)Pa; PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d7477ec6a53014a487863","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p 5.9.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p 5.9.1 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p 5.9.1","categories":["petro"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p 5.9.1","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p 5.9.1","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a487864","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"stała utrata powietrza","range":"(1) Pa;"},{"name":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstała utrata powietrza (1) Pa;\n(0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 Załącznik I","norm_bases":["PN-EN 16510-1:2023-06 Załącznik I"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Zakres:\nstała utrata powietrza (1) Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Zakres:\nstala utrata powietrza (1) Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Zalacznik I","categories":["petro"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"constant air loss","range":"(1) Pa;"},{"name":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC constant air loss (0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 持续漏气量 PN-EN 16510-1:2023-06 Załącznik I","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"持续漏气量","range":"(1) Pa;"},{"name":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a487865","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej","range":"(2 - 4000)"},{"name":"W metoda przetworników mocy"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\npomiar zużycia energii elektrycznej (2 - 4000)\nW metoda przetworników mocy","reference":"PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“","norm_bases":["PN-EN 16510-1:2023-06 p 6.11","PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Zakres:\npomiar zużycia energii elektrycznej (2 - 4000)\nW metoda przetworników mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Zakres:\npomiar zuzycia energii elektrycznej (2 - 4000)\nW metoda przetwornikow mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“","categories":["petro"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"measurement of electrical energy consumption","range":"(2 - 4000)"},{"name":"W power transducer method"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of electrical energy consumption W power transducer method PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 电能消耗测量 PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"电能消耗测量","range":"(2 - 4000)"},{"name":"W metoda przetworników mocy"}]},{"_id":"6a7d7477ec6a53014a487866","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4","categories":["petro"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature safety test"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature safety test PN-EN 16510-1:2023-06 p A.4.10.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度安全性试验 PN-EN 16510-1:2023-06 p A.4.10.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d7477ec6a53014a487867","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5","categories":["petro"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"safety test under natural draught"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC safety test under natural draught PN-EN 16510-1:2023-06 p A.4.10.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p A.4.10.5","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d7477ec6a53014a487868","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"nośność"}],"technique":null,"techniques":[],"computed":[],"activity":"nośność","reference":"PN-EN 16510-1:2023-06 p A.4.10.2","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE nośność PN-EN 16510-1:2023-06 p A.4.10.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE nosnosc PN-EN 16510-1:2023-06 p A.4.10.2","categories":["petro"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"load-bearing capacity"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC load-bearing capacity PN-EN 16510-1:2023-06 p A.4.10.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 承载力 PN-EN 16510-1:2023-06 p A.4.10.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"承载力"}]},{"_id":"6a7d7477ec6a53014a487869","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"},{"name":"sezonowa efektywność ogrzewania pomieszczeń (z obliczeń)"},{"name":"współczynnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE Zakres:\nefektywnosc (z obliczen)\nsezonowa efektywnosc ogrzewania pomieszczen (z obliczen)\nwspolczynnik efektywnosci energetycznej EEI (z obliczen) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“","categories":["petro"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"efficiency (calculated)"},{"name":"seasonal space heating efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 效率（由计算得出） 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"效率（由计算得出）"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a48786a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“","categories":["petro"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃料参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"燃料参数："},{"_id":"6a7d7477ec6a53014a48786b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"(10 - 50) %"},{"name":"wartość opałowa","range":"(10 - 32) MJ/kg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń) Procedura nr LGP/42/B wyd. 4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\nzawartosc wilgoci w drewnie (10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg\n(z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"(10 - 50) %"},{"name":"net calorific value","range":"(10 - 32) MJ/kg"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"木材含水率","range":"(10 - 50) %"},{"name":"低位发热量","range":"(10 - 32) MJ/kg"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 （计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d7477ec6a53014a48786c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}]},{"_id":"6a7d7477ec6a53014a48786d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"烟气参数："},{"_id":"6a7d7477ec6a53014a48786e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"temperatura","range":"(15 - 600) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (15 - 600) oC","reference":"PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 A.4.4.3, A.6.2","PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM temperatura (15 - 600) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM temperatura (15 - 600) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“","categories":["petro"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(15 - 600) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“","parameters_zh":[{"name":"温度","range":"(15 - 600) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d7477ec6a53014a48786f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4","PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM ciśnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM cisnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“","categories":["petro"],"row_index":297,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d7477ec6a53014a487870","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2","range":"(0,5 - 16) %"},{"name":"CO","range":"(0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2 (0,5 - 16) %\nCO (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3","PN-EN 16510-2-2:2023-06 p. 4.2 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2 (0,5 - 16) %\nCO (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2 (0,5 - 16) %\nCO (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“","categories":["petro"],"row_index":298,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2","range":"(0,5 - 16) %"},{"name":"CO","range":"(0,0003 - 4,0) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2 CO PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 CO2 CO PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“","parameters_zh":[{"name":"CO2","range":"(0,5 - 16) %"},{"name":"CO","range":"(0,0003 - 4,0) %"}],"technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a487871","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","categories":["petro","environment"],"row_index":299,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO (5 - 440) mg/m3 OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"NO (5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a487872","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"Stężenie pyłów w spalinach (0,002 - 1) g/m3","parameters":[],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-2:2023-06 p. 4.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Stezenie pylow w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“","categories":["petro"],"row_index":300,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases (0,002 - 1) g/m3","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Dust concentration in flue gases (0,002 - 1) g/m3 Gravimetric method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“","technique_en":"Gravimetric method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 烟气中粉尘浓度 (0,002 - 1) g/m3 重量法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“","technique_zh":"重量法","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"烟气中粉尘浓度 (0,002 - 1) g/m3"},{"_id":"6a7d7477ec6a53014a487873","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-2:2023-06 p. 4.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“","categories":["petro"],"row_index":301,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 空气参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"空气参数："},{"_id":"6a7d7477ec6a53014a487874","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":302,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d7477ec6a53014a487875","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":303,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"水参数："},{"_id":"6a7d7477ec6a53014a487876","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"temperatura","range":"(10 -1 00) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 -1 00) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM temperatura (10 -1 00) oC PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM temperatura (10 -1 00) oC PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":304,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 -1 00) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(10 -1 00) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d7477ec6a53014a487877","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM strumień objętości (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM strumien objetosci (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":305,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a487878","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":306,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d7477ec6a53014a487879","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2","categories":["petro"],"row_index":307,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}]},{"_id":"6a7d7477ec6a53014a48787a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2","categories":["petro"],"row_index":308,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}]},{"_id":"6a7d7477ec6a53014a48787b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM straty niezupełnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM straty niezupelnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3","categories":["petro"],"row_index":309,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a48787c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM strata niecałkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM strata niecalkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4","categories":["petro"],"row_index":310,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a48787d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1","PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM sprawność cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM sprawnosc cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“","categories":["petro"],"row_index":311,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}]},{"_id":"6a7d7477ec6a53014a48787e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2","PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM łączna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM laczna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“","categories":["petro"],"row_index":312,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(2 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. total heat output PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总热功率 PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"总热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a48787f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(1,5 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (1,5 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.3","PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“","categories":["petro"],"row_index":313,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(1,5 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"水循环回路热功率","range":"(1,5 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a487880","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4","categories":["petro"],"row_index":314,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(2 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"向房间输出的热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a487881","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4)%"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4)%","reference":"PN-EN 16510-1:2023-06 p.A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM zawartość CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM zawartosc CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6","categories":["petro"],"row_index":315,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4)%"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4)%"}]},{"_id":"6a7d7477ec6a53014a487882","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(1 - 100) g/s"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń)","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\nstrumien masy spalin (1 - 100) g/s\n(z obliczen) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“","categories":["petro"],"row_index":316,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"flue gas mass flow","range":"(1 - 100) g/s"},{"name":"(calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow (calculated) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"烟气质量流量","range":"(1 - 100) g/s"},{"name":"（计算得出）"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 （计算得出） PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d7477ec6a53014a487883","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"PARAMETRY TECHNICZNO-EKSPOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO-EKSPOATACYJNE:","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY TECHNICZNO-EKSPOATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM PARAMETRY TECHNICZNO-EKSPOATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“","categories":["petro"],"row_index":317,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 技术与运行参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"技术与运行参数："},{"_id":"6a7d7477ec6a53014a487884","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) oC"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200) oC"},{"name":"temperatura uchwytów","range":"(0 - 200) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6","PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytow (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“","categories":["petro"],"row_index":318,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) oC"},{"name":"temperature of the fuel hopper","range":"(0 - 200) oC"},{"name":"temperature of handles","range":"(0 - 200) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) oC"},{"name":"燃料储斗温度","range":"(0 - 200) oC"},{"name":"手柄温度","range":"(0 - 200) oC"}]},{"_id":"6a7d7477ec6a53014a487885","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6","PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“","categories":["petro"],"row_index":319,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}]},{"_id":"6a7d7477ec6a53014a487886","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) oC"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) oC\ncisnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7","categories":["petro","water"],"row_index":320,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) oC"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p A.4.10.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p A.4.10.7","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) oC"},{"name":"水压","range":"(0,1 - 0,3) MPa"}]},{"_id":"6a7d7477ec6a53014a487887","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"szczelność (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (5 - 75) Pa; (0,2 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM szczelność (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM szczelnosc (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","categories":["petro"],"row_index":321,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness (5 - 75) Pa; PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 密封性 (5 - 75) Pa； PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"密封性 (5 - 75) Pa；","range":"(0,2 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a487888","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p 5.9.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p 5.9.1 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p 5.9.1","categories":["petro"],"row_index":322,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p 5.9.1","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p 5.9.1","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a487889","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"stała utrata powietrza","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstała utrata powietrza (1)Pa;\n(0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 Załącznik I","norm_bases":["PN-EN 16510-1:2023-06 Załącznik I"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\nstała utrata powietrza (1)Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\nstala utrata powietrza (1)Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Zalacznik I","categories":["petro"],"row_index":323,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"constant air loss","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC constant air loss (0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 持续漏气量 PN-EN 16510-1:2023-06 Załącznik I","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"持续漏气量","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a48788a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej","range":"(2 - 4000) W"}],"technique":"Metoda przetworników mocy","techniques":["Metoda przetworników mocy"],"computed":[],"activity":"pomiar zużycia energii elektrycznej (2 - 4000) W\nMetoda przetworników mocy","reference":"PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“","norm_bases":["PN-EN 16510-1:2023-06 p 6.11","PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM pomiar zużycia energii elektrycznej (2 - 4000) W\nMetoda przetworników mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM pomiar zuzycia energii elektrycznej (2 - 4000) W\nMetoda przetwornikow mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“","categories":["petro"],"row_index":324,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"measurement of electrical energy consumption","range":"(2 - 4000) W"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Power transducer method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of electrical energy consumption PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“","technique_en":"Power transducer method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 功率传感器法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 电能消耗测量 PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"电能消耗测量","range":"(2 - 4000) W"}],"technique_zh":"功率传感器法"},{"_id":"6a7d7477ec6a53014a48788b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4","categories":["petro"],"row_index":325,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature safety test"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature safety test PN-EN 16510-1:2023-06 p A.4.10.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度安全性试验 PN-EN 16510-1:2023-06 p A.4.10.4","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d7477ec6a53014a48788c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5","categories":["petro"],"row_index":326,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"safety test under natural draught"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC safety test under natural draught PN-EN 16510-1:2023-06 p A.4.10.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p A.4.10.5","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d7477ec6a53014a48788d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"},{"name":"sezonowa efektywność ogrzewania pomieszczeń (z obliczeń)"},{"name":"współczynnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA ZABUDOWANE, W TYM Z OTWARTYM OGNIEM Zakres:\nefektywnosc (z obliczen)\nsezonowa efektywnosc ogrzewania pomieszczen (z obliczen)\nwspolczynnik efektywnosci energetycznej EEI (z obliczen) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“","categories":["petro"],"row_index":327,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"efficiency (calculated)"},{"name":"seasonal space heating efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 效率（由计算得出） 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"效率（由计算得出）"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a48788e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“","categories":["petro"],"row_index":328,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃料参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"燃料参数："},{"_id":"6a7d7477ec6a53014a48788f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"(10 - 50) %"},{"name":"wartość opałowa","range":"(10 - 32) MJ/kg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń) Procedura nr LGP/42/B wyd. 4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nzawartosc wilgoci w drewnie (10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg\n(z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":329,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"(10 - 50) %"},{"name":"net calorific value","range":"(10 - 32) MJ/kg"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"木材含水率","range":"(10 - 50) %"},{"name":"低位发热量","range":"(10 - 32) MJ/kg"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 （计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d7477ec6a53014a487890","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":330,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}]},{"_id":"6a7d7477ec6a53014a487891","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":331,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"烟气参数："},{"_id":"6a7d7477ec6a53014a487892","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"temperatura","range":"(15 - 600) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (15 - 600) oC","reference":"PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 A.4.4.3, A.6.2","PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO temperatura (15 - 600) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO temperatura (15 - 600) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“","categories":["petro"],"row_index":332,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(15 - 600) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“","parameters_zh":[{"name":"温度","range":"(15 - 600) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d7477ec6a53014a487893","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4","PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO ciśnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO cisnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“","categories":["petro"],"row_index":333,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d7477ec6a53014a487894","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"Stężenia dwutlenku węgla, tlenku węgla. Zakres:","parameters":[{"name":"CO2; (0,5 - 16) %"},{"name":"CO; (0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla. Zakres:\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A. | PN-EN 16510-2-6:2023-06 p. 4.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.","PN-EN 16510-2-6:2023-06 p. 4.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Stężenia dwutlenku węgla, tlenku węgla. Zakres:\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A. | PN-EN 16510-2-6:2023-06 p. 4.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Stezenia dwutlenku wegla, tlenku wegla. Zakres:\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A. | PN-EN 16510-2-6:2023-06 p. 4.3 „N“","categories":["petro"],"row_index":334,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide. Range:","parameters_en":[{"name":"CO2; (0,5 - 16) %"},{"name":"CO; (0,0003 - 4,0) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Concentrations of carbon dioxide, carbon monoxide. Range: Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % PN-EN 16510-1:2023-06 p. A.4.4.2, A. | PN-EN 16510-2-6:2023-06 p. 4.3 „N“","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 二氧化碳、一氧化碳浓度。范围： 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A. | PN-EN 16510-2-6:2023-06 p. 4.3 „N“","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"二氧化碳、一氧化碳浓度。范围："},{"_id":"6a7d7477ec6a53014a487895","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“","categories":["petro","environment"],"row_index":335,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO (5 - 440) mg/m3 OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"NO (5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a487896","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"Stężenie pyłów w spalinach (0,002 - 1) g/m3","parameters":[],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-6:2023-06 p. 4.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Stezenie pylow w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“","categories":["petro"],"row_index":336,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases (0,002 - 1) g/m3","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Dust concentration in flue gases (0,002 - 1) g/m3 Gravimetric method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“","technique_en":"Gravimetric method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 烟气中粉尘浓度 (0,002 - 1) g/m3 重量法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“","technique_zh":"重量法","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"烟气中粉尘浓度 (0,002 - 1) g/m3"},{"_id":"6a7d7477ec6a53014a487897","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-6:2023-06 p. 4.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“","categories":["petro"],"row_index":337,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 空气参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"空气参数："},{"_id":"6a7d7477ec6a53014a487898","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"temperatura","range":"(10-35) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10-35) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO temperatura (10-35) oC PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO temperatura (10-35) oC PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":338,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10-35) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10-35) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d7477ec6a53014a487899","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":339,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"水参数："},{"_id":"6a7d7477ec6a53014a48789a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 100) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 100) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO temperatura (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO temperatura (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":340,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 100) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(10 - 100) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d7477ec6a53014a48789b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO strumień objętości (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO strumien objetosci (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":341,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a48789c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":342,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d7477ec6a53014a48789d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2","categories":["petro"],"row_index":343,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}]},{"_id":"6a7d7477ec6a53014a48789e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2","categories":["petro"],"row_index":344,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}]},{"_id":"6a7d7477ec6a53014a48789f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO straty niezupełnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO straty niezupelnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3","categories":["petro"],"row_index":345,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a4878a0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO strata niecałkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO strata niecalkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4","categories":["petro"],"row_index":346,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a4878a1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1","PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO sprawność cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO sprawnosc cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“","categories":["petro"],"row_index":347,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}]},{"_id":"6a7d7477ec6a53014a4878a2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2","PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO łączna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO laczna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“","categories":["petro"],"row_index":348,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(2 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. total heat output PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总热功率 PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"总热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a4878a3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(1,5 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (1,5 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.3","PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“","categories":["petro"],"row_index":349,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(1,5 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"水循环回路热功率","range":"(1,5 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a4878a4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4","categories":["petro"],"row_index":350,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(2 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"向房间输出的热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a4878a5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4)%"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4)%","reference":"PN-EN 16510-1:2023-06 p.A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO zawartość CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO zawartosc CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6","categories":["petro"],"row_index":351,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4)%"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4)%"}]},{"_id":"6a7d7477ec6a53014a4878a6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(1 - 100) g/s"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń)","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nstrumien masy spalin (1 - 100) g/s\n(z obliczen) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“","categories":["petro"],"row_index":352,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"flue gas mass flow","range":"(1 - 100) g/s"},{"name":"(calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow (calculated) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"烟气质量流量","range":"(1 - 100) g/s"},{"name":"（计算得出）"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 （计算得出） PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d7477ec6a53014a4878a7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"PARAMETRY TECHNICZNO-EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO-EKSPLOATACYJNE:","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY TECHNICZNO-EKSPLOATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO PARAMETRY TECHNICZNO-EKSPLOATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“","categories":["petro"],"row_index":353,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d7477ec6a53014a4878a8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) oC"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200) oC"},{"name":"temperatura uchwytów","range":"(0 - 200) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6","PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytow (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“","categories":["petro"],"row_index":354,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) oC"},{"name":"temperature of the fuel hopper","range":"(0 - 200) oC"},{"name":"temperature of handles","range":"(0 - 200) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) oC"},{"name":"燃料储斗温度","range":"(0 - 200) oC"},{"name":"手柄温度","range":"(0 - 200) oC"}]},{"_id":"6a7d7477ec6a53014a4878a9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6","PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“","categories":["petro"],"row_index":355,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}]},{"_id":"6a7d7477ec6a53014a4878aa","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) oC"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) oC\ncisnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7","categories":["petro","water"],"row_index":356,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) oC"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p A.4.10.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p A.4.10.7","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) oC"},{"name":"水压","range":"(0,1 - 0,3) MPa"}]},{"_id":"6a7d7477ec6a53014a4878ab","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"szczelność (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (5 - 75) Pa; (0,2 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO szczelność (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO szczelnosc (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“","categories":["petro"],"row_index":357,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness (5 - 75) Pa; PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 密封性 (5 - 75) Pa； PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"密封性 (5 - 75) Pa；","range":"(0,2 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a4878ac","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p 5.9.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p 5.9.1 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p 5.9.1","categories":["petro"],"row_index":358,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p 5.9.1","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p 5.9.1","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a4878ad","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"stała utrata powietrza","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstała utrata powietrza (1)Pa;\n(0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 Załącznik I","norm_bases":["PN-EN 16510-1:2023-06 Załącznik I"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nstała utrata powietrza (1)Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nstala utrata powietrza (1)Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Zalacznik I","categories":["petro"],"row_index":359,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"constant air loss","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC constant air loss (0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 持续漏气量 PN-EN 16510-1:2023-06 Załącznik I","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"持续漏气量","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a4878ae","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej","range":"(2 - 4000) W"}],"technique":"Metoda przetworników mocy","techniques":["Metoda przetworników mocy"],"computed":[],"activity":"pomiar zużycia energii elektrycznej (2 - 4000) W\nMetoda przetworników mocy","reference":"PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“","norm_bases":["PN-EN 16510-1:2023-06 p 6.11","PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO pomiar zużycia energii elektrycznej (2 - 4000) W\nMetoda przetworników mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO pomiar zuzycia energii elektrycznej (2 - 4000) W\nMetoda przetwornikow mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“","categories":["petro"],"row_index":360,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"measurement of electrical energy consumption","range":"(2 - 4000) W"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Power transducer method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of electrical energy consumption PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“","technique_en":"Power transducer method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 功率传感器法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 电能消耗测量 PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"电能消耗测量","range":"(2 - 4000) W"}],"technique_zh":"功率传感器法"},{"_id":"6a7d7477ec6a53014a4878af","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4","categories":["petro"],"row_index":361,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature safety test"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature safety test PN-EN 16510-1:2023-06 p A.4.10.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度安全性试验 PN-EN 16510-1:2023-06 p A.4.10.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d7477ec6a53014a4878b0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5","categories":["petro"],"row_index":362,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"safety test under natural draught"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC safety test under natural draught PN-EN 16510-1:2023-06 p A.4.10.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p A.4.10.5","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d7477ec6a53014a4878b1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"działanie ogranicznika temperatury bezpieczeństwa","range":"(0 - 110) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"działanie ogranicznika temperatury bezpieczeństwa (0 - 110) oC","reference":"PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7","PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO działanie ogranicznika temperatury bezpieczeństwa (0 - 110) oC PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO dzialanie ogranicznika temperatury bezpieczenstwa (0 - 110) oC PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“","categories":["petro"],"row_index":363,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"operation of the safety temperature limiter","range":"(0 - 110) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. operation of the safety temperature limiter PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 安全温度限制器的动作 PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"安全温度限制器的动作","range":"(0 - 110) oC"}]},{"_id":"6a7d7477ec6a53014a4878b2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"zanik zasilania elektrycznego","range":"(0 - 110) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"zanik zasilania elektrycznego (0 - 110) oC","reference":"PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7","PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO zanik zasilania elektrycznego (0 - 110) oC PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO zanik zasilania elektrycznego (0 - 110) oC PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“","categories":["petro"],"row_index":364,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss of electrical power supply","range":"(0 - 110) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. loss of electrical power supply PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 供电中断 PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"供电中断","range":"(0 - 110) oC"}]},{"_id":"6a7d7477ec6a53014a4878b3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"zanik odbioru ciepła (0 - 110) oC,","range":"(0 - 5) %"},{"name":"CO"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzanik odbioru ciepła (0 - 110) oC, (0 - 5) %\nCO","reference":"PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7","PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nzanik odbioru ciepła (0 - 110) oC, (0 - 5) %\nCO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nzanik odbioru ciepla (0 - 110) oC, (0 - 5) %\nCO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“","categories":["petro"],"row_index":365,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss of heat removal (0 - 110) oC,","range":"(0 - 5) %"},{"name":"CO"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. loss of heat removal (0 - 110) oC, CO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 散热中断 (0 - 110) oC， CO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“","parameters_zh":[{"name":"散热中断 (0 - 110) oC，","range":"(0 - 5) %"},{"name":"CO"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d7477ec6a53014a4878b4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"nośność"}],"technique":null,"techniques":[],"computed":[],"activity":"nośność","reference":"PN-EN 16510-1:2023-06 p A.4.10.2","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO nośność PN-EN 16510-1:2023-06 p A.4.10.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO nosnosc PN-EN 16510-1:2023-06 p A.4.10.2","categories":["petro"],"row_index":366,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"load-bearing capacity"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC load-bearing capacity PN-EN 16510-1:2023-06 p A.4.10.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 承载力 PN-EN 16510-1:2023-06 p A.4.10.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"承载力"}]},{"_id":"6a7d7477ec6a53014a4878b5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO","methodology":"","parameters":[{"name":"efektywność (z obliczeń),"},{"name":"sezonowa efektywność ogrzewania pomieszczeń (z obliczeń)"},{"name":"współczynnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń),\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - OGRZEWACZE POKOJOWE, URZĄDZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nefektywność (z obliczeń),\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - OGRZEWACZE POKOJOWE, URZADZENIA ZABUDOWANE, I KUCHENKI, Z MECHANICZNYM PODAWANIEM PELLETU DRZEWNEGO Zakres:\nefektywnosc (z obliczen),\nsezonowa efektywnosc ogrzewania pomieszczen (z obliczen)\nwspolczynnik efektywnosci energetycznej EEI (z obliczen) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“","categories":["petro"],"row_index":367,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"efficiency (calculated),"},{"name":"seasonal space heating efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated), seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"efektywność (z obliczeń),"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a4878b6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“","categories":["petro"],"row_index":368,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃料参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"燃料参数："},{"_id":"6a7d7477ec6a53014a4878b7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"( 10 - 50) %"},{"name":"wartość opałowa","range":"(10 - 32) MJ/kg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie ( 10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI Zakres:\nzawartość wilgoci w drewnie ( 10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń) Procedura nr LGP/42/B wyd. 4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI Zakres:\nzawartosc wilgoci w drewnie ( 10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg\n(z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":369,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"( 10 - 50) %"},{"name":"net calorific value","range":"(10 - 32) MJ/kg"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"木材含水率","range":"( 10 - 50) %"},{"name":"低位发热量","range":"(10 - 32) MJ/kg"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 （计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878b8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":370,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}]},{"_id":"6a7d7477ec6a53014a4878b9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":371,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"烟气参数："},{"_id":"6a7d7477ec6a53014a4878ba","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"temperatura","range":"(15 - 600) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (15 - 600) oC","reference":"PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 A.4.4.3, A.6.2","PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI temperatura (15 - 600) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI temperatura (15 - 600) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N”","categories":["petro"],"row_index":372,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(15 - 600) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N”","parameters_zh":[{"name":"温度","range":"(15 - 600) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878bb","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"ciśnienie (-10 - 10) hPa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4","PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI ciśnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI cisnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","categories":["petro"],"row_index":373,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"pressure (-10 - 10) hPa","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS pressure (-10 - 10) hPa Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878bc","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"Stężenia dwutlenku węgla, tlenku węgla. Zakres:","parameters":[{"name":"CO2 (0,5 - 16) %"},{"name":"CO (0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla. Zakres:\nZakres:\nCO2 (0,5 - 16) %\nCO (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4","PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI Stężenia dwutlenku węgla, tlenku węgla. Zakres:\nZakres:\nCO2 (0,5 - 16) %\nCO (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI Stezenia dwutlenku wegla, tlenku wegla. Zakres:\nZakres:\nCO2 (0,5 - 16) %\nCO (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","categories":["petro"],"row_index":374,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide. Range:","parameters_en":[{"name":"CO2 (0,5 - 16) %"},{"name":"CO (0,0003 - 4,0) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Concentrations of carbon dioxide, carbon monoxide. Range: Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2 (0,5 - 16) % CO (0,0003 - 4,0) % PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 二氧化碳、一氧化碳浓度。范围： 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"二氧化碳、一氧化碳浓度。范围："},{"_id":"6a7d7477ec6a53014a4878bd","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N”","categories":["petro","environment"],"row_index":375,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO (5 - 440) mg/m3 OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N”","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"NO (5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a4878be","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"Stężenie pyłów w spalinach (0,002 - 1) g/m3","parameters":[],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-3:2023-06 p. 4.5 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI Stezenie pylow w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","categories":["petro"],"row_index":376,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases (0,002 - 1) g/m3","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Dust concentration in flue gases (0,002 - 1) g/m3 Gravimetric method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","technique_en":"Gravimetric method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 烟气中粉尘浓度 (0,002 - 1) g/m3 重量法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","technique_zh":"重量法","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"烟气中粉尘浓度 (0,002 - 1) g/m3"},{"_id":"6a7d7477ec6a53014a4878bf","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-3:2023-06 p. 4.5 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","categories":["petro"],"row_index":377,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 空气参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"空气参数："},{"_id":"6a7d7477ec6a53014a4878c0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"temperatura powietrza","range":"(10 - 35) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura powietrza (10 - 35) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI temperatura powietrza (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI temperatura powietrza (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":378,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"air temperature","range":"(10 - 35) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC air temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878c1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":379,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"水参数："},{"_id":"6a7d7477ec6a53014a4878c2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"temperatura wody","range":"(10 - 100) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura wody (10 - 100) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI temperatura wody (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI temperatura wody (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro","water"],"row_index":380,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"water temperature","range":"(10 - 100) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC water temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878c3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"strumień objętości wody","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości wody (0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI strumień objętości wody (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI strumien objetosci wody (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro","water"],"row_index":381,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"water volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC water volume flow rate PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878c4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"BILANS CIEPLNY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY:","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI BILANS CIEPLNY: PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI BILANS CIEPLNY: PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":382,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS HEAT BALANCE: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878c5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2","categories":["petro"],"row_index":383,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}]},{"_id":"6a7d7477ec6a53014a4878c6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1."],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1. MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.","categories":["petro"],"row_index":384,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 16510-1:2023-06 p.A.6.2.1.","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 16510-1:2023-06 p.A.6.2.1.","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}]},{"_id":"6a7d7477ec6a53014a4878c7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI straty niezupełnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI straty niezupelnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3","categories":["petro"],"row_index":385,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a4878c8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI strata niecałkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI strata niecalkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4","categories":["petro"],"row_index":386,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a4878c9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1","PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI sprawność cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI sprawnosc cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”","categories":["petro"],"row_index":387,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}]},{"_id":"6a7d7477ec6a53014a4878ca","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI łączna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI laczna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2","categories":["petro"],"row_index":388,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(2 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC total heat output PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 总热功率 PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"总热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a4878cb","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(1,5 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (1,5 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.3","PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”","categories":["petro"],"row_index":389,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(1,5 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"水循环回路热功率","range":"(1,5 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a4878cc","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.4","PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”","categories":["petro"],"row_index":390,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(2 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output to the room PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 向房间输出的热功率 PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"向房间输出的热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a4878cd","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(1 - 100) g/s"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń)","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI Zakres:\nstrumien masy spalin (1 - 100) g/s\n(z obliczen) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","categories":["petro"],"row_index":391,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"flue gas mass flow","range":"(1 - 100) g/s"},{"name":"(calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow (calculated) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"烟气质量流量","range":"(1 - 100) g/s"},{"name":"（计算得出）"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 （计算得出） PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878ce","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"PARAMETRY TECHNICZNO-EKSPLIATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO-EKSPLIATACYJNE:","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI PARAMETRY TECHNICZNO-EKSPLIATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI PARAMETRY TECHNICZNO-EKSPLIATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","categories":["petro"],"row_index":392,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878cf","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura narożnika pomiarowego i podłoża (0 - 200) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6 | PN-EN 16510-2-3:2023-06 p.4.1 „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6","PN-EN 16510-2-3:2023-06 p.4.1 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI temperatura narożnika pomiarowego i podłoża (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6 | PN-EN 16510-2-3:2023-06 p.4.1 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI temperatura naroznika pomiarowego i podloza (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6 | PN-EN 16510-2-3:2023-06 p.4.1 „N”","categories":["petro"],"row_index":393,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6 | PN-EN 16510-2-3:2023-06 p.4.1 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6 | PN-EN 16510-2-3:2023-06 p.4.1 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) oC"}]},{"_id":"6a7d7477ec6a53014a4878d0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"temperatura zasobnika paliwa","range":"(0 - 200) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura zasobnika paliwa (0 - 200) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4","PN-EN 16510-2-3:2023-06 p. 5.5 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI temperatura zasobnika paliwa (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI temperatura zasobnika paliwa (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”","categories":["petro"],"row_index":394,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the fuel hopper","range":"(0 - 200) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the fuel hopper PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 燃料储斗温度 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"燃料储斗温度","range":"(0 - 200) oC"}]},{"_id":"6a7d7477ec6a53014a4878d1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"PARAMETRY TECHNICZNO-EKSPLIATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO-EKSPLIATACYJNE:","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4","PN-EN 16510-2-3:2023-06 p. 5.5 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI PARAMETRY TECHNICZNO-EKSPLIATACYJNE: PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI PARAMETRY TECHNICZNO-EKSPLIATACYJNE: PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”","categories":["petro"],"row_index":395,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878d2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"temperatura uchwytów","range":"(0 - 200) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura uchwytów (0 - 200) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5 | PN-EN 16510-2-3:2023-06 p.5.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5","PN-EN 16510-2-3:2023-06 p.5.6 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI temperatura uchwytów (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5 | PN-EN 16510-2-3:2023-06 p.5.6 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI temperatura uchwytow (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5 | PN-EN 16510-2-3:2023-06 p.5.6 „N”","categories":["petro"],"row_index":396,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of handles","range":"(0 - 200) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of handles PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5 | PN-EN 16510-2-3:2023-06 p.5.6 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 手柄温度 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5 | PN-EN 16510-2-3:2023-06 p.5.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"手柄温度","range":"(0 - 200) oC"}]},{"_id":"6a7d7477ec6a53014a4878d3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.9 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6","PN-EN 16510-2-3:2023-06 p. 5.9 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.9 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.9 „N”","categories":["petro"],"row_index":397,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.9 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.9 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}]},{"_id":"6a7d7477ec6a53014a4878d4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) oC"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) oC\ncisnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7","categories":["petro","water"],"row_index":398,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) oC"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p A.4.10.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p A.4.10.7","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) oC"},{"name":"水压","range":"(0,1 - 0,3) MPa"}]},{"_id":"6a7d7477ec6a53014a4878d5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"szczelność (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (5 - 75) Pa; (0,2 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI szczelność (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI szczelnosc (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","categories":["petro"],"row_index":399,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness (5 - 75) Pa; PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 密封性 (5 - 75) Pa； PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"密封性 (5 - 75) Pa；","range":"(0,2 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a4878d6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p 5.9.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p 5.9.1 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p 5.9.1","categories":["petro"],"row_index":400,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p 5.9.1","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p 5.9.1","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a4878d7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"stała utrata powietrza (1) Pa;","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"stała utrata powietrza (1) Pa; (0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 Załącznik I","norm_bases":["PN-EN 16510-1:2023-06 Załącznik I"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI stała utrata powietrza (1) Pa; (0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI stala utrata powietrza (1) Pa; (0 - 3) m3/h PN-EN 16510-1:2023-06 Zalacznik I","categories":["petro"],"row_index":401,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"constant air loss (1) Pa;","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC constant air loss (1) Pa; PN-EN 16510-1:2023-06 Załącznik I","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 Załącznik I","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878d8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej","range":"(2 - 4000) W"}],"technique":"Metoda przetworników mocy","techniques":["Metoda przetworników mocy"],"computed":[],"activity":"pomiar zużycia energii elektrycznej (2 - 4000) W\nMetoda przetworników mocy","reference":"PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","norm_bases":["PN-EN 16510-1:2023-06 p 6.11","PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI pomiar zużycia energii elektrycznej (2 - 4000) W\nMetoda przetworników mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI pomiar zuzycia energii elektrycznej (2 - 4000) W\nMetoda przetwornikow mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","categories":["petro"],"row_index":402,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"measurement of electrical energy consumption","range":"(2 - 4000) W"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Power transducer method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of electrical energy consumption PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","technique_en":"Power transducer method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 功率传感器法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 电能消耗测量 PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"电能消耗测量","range":"(2 - 4000) W"}],"technique_zh":"功率传感器法"},{"_id":"6a7d7477ec6a53014a4878d9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4","categories":["petro"],"row_index":403,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature safety test"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature safety test PN-EN 16510-1:2023-06 p A.4.10.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度安全性试验 PN-EN 16510-1:2023-06 p A.4.10.4","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d7477ec6a53014a4878da","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5","categories":["petro"],"row_index":404,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"safety test under natural draught"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC safety test under natural draught PN-EN 16510-1:2023-06 p A.4.10.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p A.4.10.5","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d7477ec6a53014a4878db","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"efektywność (z obliczeń),"},{"name":"sezonowa efektywność ogrzewania pomieszczeń (z obliczeń),"},{"name":"EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń),\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń),\nEEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI Zakres:\nefektywność (z obliczeń),\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń),\nEEI (z obliczeń) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI Zakres:\nefektywnosc (z obliczen),\nsezonowa efektywnosc ogrzewania pomieszczen (z obliczen),\nEEI (z obliczen) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”","categories":["petro"],"row_index":405,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"efficiency (calculated),"},{"name":"seasonal space heating efficiency (calculated),"},{"name":"EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated), seasonal space heating efficiency (calculated), EEI (calculated) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878dc","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"pomiar temperatury piekarnika, temperatura powietrza","range":"(0 - 300) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"pomiar temperatury piekarnika, temperatura powietrza (0 - 300) oC","reference":"PN-EN 16510-2-3:2023-06 A.4.301.1 „N”","norm_bases":["PN-EN 16510-2-3:2023-06 A.4.301.1 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI pomiar temperatury piekarnika, temperatura powietrza (0 - 300) oC PN-EN 16510-2-3:2023-06 A.4.301.1 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI pomiar temperatury piekarnika, temperatura powietrza (0 - 300) oC PN-EN 16510-2-3:2023-06 A.4.301.1 „N”","categories":["petro"],"row_index":406,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"measurement of oven temperature, air temperature","range":"(0 - 300) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of oven temperature, air temperature PN-EN 16510-2-3:2023-06 A.4.301.1 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-2-3:2023-06 A.4.301.1 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878dd","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"próba gotowania na płycie grzewczej, temperatura wody","range":"(0 - 100) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"próba gotowania na płycie grzewczej, temperatura wody (0 - 100) oC","reference":"PN-EN 16510-2-3:2023-06 A.4.301.2 „N”","norm_bases":["PN-EN 16510-2-3:2023-06 A.4.301.2 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI próba gotowania na płycie grzewczej, temperatura wody (0 - 100) oC PN-EN 16510-2-3:2023-06 A.4.301.2 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI proba gotowania na plycie grzewczej, temperatura wody (0 - 100) oC PN-EN 16510-2-3:2023-06 A.4.301.2 „N”","categories":["petro","water"],"row_index":407,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"boiling test on a hotplate, water temperature","range":"(0 - 100) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. boiling test on a hotplate, water temperature PN-EN 16510-2-3:2023-06 A.4.301.2 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-2-3:2023-06 A.4.301.2 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d7477ec6a53014a4878de","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI","methodology":"","parameters":[{"name":"pieczenie, temperatura powietrza","range":"(0 - 300) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"pieczenie, temperatura powietrza (0 - 300) oC","reference":"PN-EN 16510-2-3:2023-06 A.4.301.3 „N”","norm_bases":["PN-EN 16510-2-3:2023-06 A.4.301.3 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - KUCHENKI pieczenie, temperatura powietrza (0 - 300) oC PN-EN 16510-2-3:2023-06 A.4.301.3 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - KUCHENKI pieczenie, temperatura powietrza (0 - 300) oC PN-EN 16510-2-3:2023-06 A.4.301.3 „N”","categories":["petro"],"row_index":408,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"baking, air temperature","range":"(0 - 300) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. baking, air temperature PN-EN 16510-2-3:2023-06 A.4.301.3 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烘烤、空气温度 PN-EN 16510-2-3:2023-06 A.4.301.3 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"烘烤、空气温度","range":"(0 - 300) oC"}]},{"_id":"6a7d7477ec6a53014a4878df","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-2-3:2023-06 A.4.301.3 „N”","norm_bases":["PN-EN 16510-2-3:2023-06 A.4.301.3 „N”"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO PARAMETRY PALIWA: PN-EN 16510-2-3:2023-06 A.4.301.3 „N” MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO PARAMETRY PALIWA: PN-EN 16510-2-3:2023-06 A.4.301.3 „N”","categories":["petro"],"row_index":409,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-2-3:2023-06 A.4.301.3 „N”","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 燃料参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-2-3:2023-06 A.4.301.3 „N”","methodology_zh":"燃料参数：","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878e0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"(10 - 50) %"},{"name":"wartość opałowa","range":"(10 - 32) MJ/kg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń) Procedura nr LGP/42/B wyd. 4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Zakres:\nzawartosc wilgoci w drewnie (10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg\n(z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":410,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"(10 - 50) %"},{"name":"net calorific value","range":"(10 - 32) MJ/kg"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"木材含水率","range":"(10 - 50) %"},{"name":"低位发热量","range":"(10 - 32) MJ/kg"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 （计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878e1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":411,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 16510-1:2023-06 p.A.4.2","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878e2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":412,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","methodology_zh":"烟气参数：","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878e3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"temperatura","range":"(15 - 1100) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (15 - 1100) oC","reference":"PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1","PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO temperatura (15 - 1100) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO temperatura (15 - 1100) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“","categories":["petro"],"row_index":413,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(15 - 1100) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“","parameters_zh":[{"name":"温度","range":"(15 - 1100) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878e4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5 | PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5","PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO ciśnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5 | PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO cisnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5 | PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“","categories":["petro"],"row_index":414,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5 | PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5 | PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878e5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-5:2025-10 p. 4.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3","PN-EN 16510-2-5:2025-10 p. 4.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-5:2025-10 p. 4.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2; (0,5 - 16) %\nCO; (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-5:2025-10 p. 4.3 „N“","categories":["petro"],"row_index":415,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2;","range":"(0,5 - 16) %"},{"name":"CO;","range":"(0,0003 - 4,0) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2; CO; PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-5:2025-10 p. 4.3 „N“","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-5:2025-10 p. 4.3 „N“","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a4878e6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“","categories":["petro","environment"],"row_index":416,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO (5 - 440) mg/m3 OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具","parameters_zh":[{"name":"NO (5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a4878e7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"Stężenie pyłów w spalinach (0,002 - 1) g/m3","parameters":[],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-5:2025-10 p. 4.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Stezenie pylow w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“","categories":["petro"],"row_index":417,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases (0,002 - 1) g/m3","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Dust concentration in flue gases (0,002 - 1) g/m3 Gravimetric method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“","technique_en":"Gravimetric method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 烟气中粉尘浓度 (0,002 - 1) g/m3 重量法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“","technique_zh":"重量法","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具","methodology_zh":"烟气中粉尘浓度 (0,002 - 1) g/m3"},{"_id":"6a7d7477ec6a53014a4878e8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-5:2025-10 p. 4.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“","categories":["petro"],"row_index":418,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 空气参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“","methodology_zh":"空气参数：","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878e9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":419,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878ea","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":420,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","methodology_zh":"水参数：","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878eb","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 100) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 100) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO temperatura (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO temperatura (10 - 100) oC PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":421,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 100) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(10 - 100) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878ec","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO strumień objętości (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO strumien objetosci (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":422,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a4878ed","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":423,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","methodology_zh":"热平衡（计算值）：","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878ee","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2","categories":["petro"],"row_index":424,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 16510-1:2023-06 p.A.6.2.2","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878ef","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"-energia cieplna doprowadzona z paliwem (10-600) MJ","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"-energia cieplna doprowadzona z paliwem (10-600) MJ","reference":"PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“","norm_bases":["PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO -energia cieplna doprowadzona z paliwem (10-600) MJ PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO -energia cieplna doprowadzona z paliwem (10-600) MJ PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“","categories":["petro"],"row_index":425,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"-thermal energy supplied with the fuel (10-600) MJ","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES -thermal energy supplied with the fuel (10-600) MJ Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878f0","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2","categories":["petro"],"row_index":426,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 16510-1:2023-06 p.A.6.2.1.2","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878f1","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO straty niezupełnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO straty niezupelnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3","categories":["petro"],"row_index":427,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.3","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878f2","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO strata niecałkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO strata niecalkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4","categories":["petro"],"row_index":428,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.4","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878f3","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1","PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO sprawność cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO sprawnosc cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“","categories":["petro"],"row_index":429,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878f4","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2","PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO łączna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO laczna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“","categories":["petro"],"row_index":430,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(2 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. total heat output PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总热功率 PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“","parameters_zh":[{"name":"总热功率","range":"(2 - 50) kW"}],"test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具"},{"_id":"6a7d7477ec6a53014a4878f5","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(1,5 - 50)"},{"name":"kW"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nmoc cieplna obiegu wodnego (1,5 - 50)\nkW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.3","PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Zakres:\nmoc cieplna obiegu wodnego (1,5 - 50)\nkW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Zakres:\nmoc cieplna obiegu wodnego (1,5 - 50)\nkW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“","categories":["petro"],"row_index":431,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(1,5 - 50)"},{"name":"kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 慢速放热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“","test_object_zh":"民用固体燃料燃烧器具 — 慢速放热器具","parameters_zh":[{"name":"水循环回路热功率","range":"(1,5 - 50)"},{"name":"kW"}]},{"_id":"6a7d7477ec6a53014a4878f6","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.4","PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“ - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“","categories":["petro"],"row_index":432,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(2 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output to the room PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 向房间输出的热功率 PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“","parameters_zh":[{"name":"向房间输出的热功率","range":"(2 - 50) kW"}],"test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具"},{"_id":"6a7d7477ec6a53014a4878f7","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4)%"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4)%","reference":"PN-EN 16510-1:2023-06 p.A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO zawartość CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6 - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO zawartosc CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6","categories":["petro"],"row_index":433,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4)%"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4)%"}]},{"_id":"6a7d7477ec6a53014a4878f8","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(1 - 100) g/s"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń)","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“ - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Zakres:\nstrumien masy spalin (1 - 100) g/s\n(z obliczen) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“","categories":["petro"],"row_index":434,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"flue gas mass flow","range":"(1 - 100) g/s"},{"name":"(calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow (calculated) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"烟气质量流量","range":"(1 - 100) g/s"},{"name":"（计算得出）"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 （计算得出） PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具"},{"_id":"6a7d7477ec6a53014a4878f9","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"-średnia różnica temperatury powierzchni urządzenia i otoczenia (0 - 200) oC","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"-średnia różnica temperatury powierzchni urządzenia i otoczenia (0 - 200) oC","reference":"PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“","norm_bases":["PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO -średnia różnica temperatury powierzchni urządzenia i otoczenia (0 - 200) oC PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“ - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO -srednia roznica temperatury powierzchni urzadzenia i otoczenia (0 - 200) oC PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“","categories":["petro"],"row_index":435,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"-mean temperature difference between the appliance surface and the surroundings (0 - 200) oC","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES -mean temperature difference between the appliance surface and the surroundings (0 - 200) oC Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具"},{"_id":"6a7d7477ec6a53014a4878fa","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"PARAMETRY TECHNICZNO-EKSPOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO-EKSPOATACYJNE:","reference":"PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“","norm_bases":["PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO PARAMETRY TECHNICZNO-EKSPOATACYJNE: PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“ - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO PARAMETRY TECHNICZNO-EKSPOATACYJNE: PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“","categories":["petro"],"row_index":436,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 技术与运行参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具","methodology_zh":"技术与运行参数："},{"_id":"6a7d7477ec6a53014a4878fb","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) oC"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200)"},{"name":"oC"},{"name":"temperatura uchwytów","range":"(0 - 200) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200)\noC\ntemperatura uchwytów (0 - 200) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6","PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200)\noC\ntemperatura uchwytów (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“ - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200)\noC\ntemperatura uchwytow (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“","categories":["petro"],"row_index":437,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) oC"},{"name":"temperature of the fuel hopper","range":"(0 - 200)"},{"name":"oC"},{"name":"temperature of handles","range":"(0 - 200) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper oC temperature of handles PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) oC"},{"name":"燃料储斗温度","range":"(0 - 200)"},{"name":"oC"},{"name":"手柄温度","range":"(0 - 200) oC"}],"test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具"},{"_id":"6a7d7477ec6a53014a4878fc","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6","categories":["petro"],"row_index":438,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}],"test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具"},{"_id":"6a7d7477ec6a53014a4878fd","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) oC"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7 - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) oC\ncisnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7","categories":["petro","water"],"row_index":439,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) oC"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p A.4.10.7","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p A.4.10.7","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) oC"},{"name":"水压","range":"(0,1 - 0,3) MPa"}],"test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具"},{"_id":"6a7d7477ec6a53014a4878fe","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"szczelność (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (5 - 75) Pa; (0,2 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO szczelność (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO szczelnosc (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","categories":["petro"],"row_index":440,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness (5 - 75) Pa; PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 密封性 (5 - 75) Pa； PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具","parameters_zh":[{"name":"密封性 (5 - 75) Pa；","range":"(0,2 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a4878ff","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p 5.9.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p 5.9.1 - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p 5.9.1","categories":["petro"],"row_index":441,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p 5.9.1","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p 5.9.1","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a487900","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"stała utrata powietrza","range":"(1) Pa;"},{"name":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstała utrata powietrza (1) Pa;\n(0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 Załącznik I","norm_bases":["PN-EN 16510-1:2023-06 Załącznik I"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Zakres:\nstała utrata powietrza (1) Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Zakres:\nstala utrata powietrza (1) Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Zalacznik I","categories":["petro"],"row_index":442,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"constant air loss","range":"(1) Pa;"},{"name":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC constant air loss (0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 持续漏气量 PN-EN 16510-1:2023-06 Załącznik I","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具","parameters_zh":[{"name":"持续漏气量","range":"(1) Pa;"},{"name":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a487901","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej (2 - 4000) W metoda przetworników mocy"}],"technique":null,"techniques":[],"computed":[],"activity":"pomiar zużycia energii elektrycznej (2 - 4000) W metoda przetworników mocy","reference":"PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 p 6.11","PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO pomiar zużycia energii elektrycznej (2 - 4000) W metoda przetworników mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“ - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO pomiar zuzycia energii elektrycznej (2 - 4000) W metoda przetwornikow mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“","categories":["petro"],"row_index":443,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"measurement of electricity consumption (2 - 4000) W power transducer method"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of electricity consumption (2 - 4000) W power transducer method PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具"},{"_id":"6a7d7477ec6a53014a487902","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.4","PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“ - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“","categories":["petro"],"row_index":444,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature safety test"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature safety test PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度安全性试验 PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d7477ec6a53014a487903","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"-badanie działania układu regulacji rozładowania ciepła i wymiennika bezpieczeństwa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"-badanie działania układu regulacji rozładowania ciepła i wymiennika bezpieczeństwa","reference":"PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7","PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO -badanie działania układu regulacji rozładowania ciepła i wymiennika bezpieczeństwa PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“ - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO -badanie dzialania ukladu regulacji rozladowania ciepla i wymiennika bezpieczenstwa PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“","categories":["petro"],"row_index":445,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"-test of the operation of the heat discharge control system and of the safety heat exchanger","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES -test of the operation of the heat discharge control system and of the safety heat exchanger Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具"},{"_id":"6a7d7477ec6a53014a487904","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"nośność"}],"technique":null,"techniques":[],"computed":[],"activity":"nośność","reference":"PN-EN 16510-1:2023-06 p A.4.10.2","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO nośność PN-EN 16510-1:2023-06 p A.4.10.2 - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO nosnosc PN-EN 16510-1:2023-06 p A.4.10.2","categories":["petro"],"row_index":446,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"load-bearing capacity"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC load-bearing capacity PN-EN 16510-1:2023-06 p A.4.10.2","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 承载力 PN-EN 16510-1:2023-06 p A.4.10.2","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具","parameters_zh":[{"name":"承载力"}]},{"_id":"6a7d7477ec6a53014a487905","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"},{"name":"sezonowa efektywność ogrzewania pomieszczeń (z obliczeń)"},{"name":"współczynnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"- MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WOLNO UWALNIAJĄCE CIEPŁO Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“ - MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WOLNO UWALNIAJACE CIEPLO Zakres:\nefektywnosc (z obliczen)\nsezonowa efektywnosc ogrzewania pomieszczen (z obliczen)\nwspolczynnik efektywnosci energetycznej EEI (z obliczen) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“","categories":["petro"],"row_index":447,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"efficiency (calculated)"},{"name":"seasonal space heating efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“","test_object_en":"- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 效率（由计算得出） 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“","test_object_zh":"－ 住宅用固体燃料燃烧器具 － 缓释热器具","parameters_zh":[{"name":"效率（由计算得出）"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a487906","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY PALIWA: PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“","categories":["petro"],"row_index":448,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS FUEL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 燃料参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","methodology_zh":"燃料参数："},{"_id":"6a7d7477ec6a53014a487907","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"zawartość wilgoci w drewnie","range":"(10 - 50) %"},{"name":"wartość opałowa","range":"(10 - 32) MJ/kg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń)","reference":"Procedura nr LGP/42/B wyd. 4","norm_bases":["Procedura nr LGP/42/B wyd. 4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nzawartość wilgoci w drewnie (10 - 50) %\nwartość opałowa (10 - 32) MJ/kg\n(z obliczeń) Procedura nr LGP/42/B wyd. 4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nzawartosc wilgoci w drewnie (10 - 50) %\nwartosc opalowa (10 - 32) MJ/kg\n(z obliczen) Procedura nr LGP/42/B wyd. 4","categories":["petro"],"row_index":449,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"moisture content in wood","range":"(10 - 50) %"},{"name":"net calorific value","range":"(10 - 32) MJ/kg"},{"name":"(calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC moisture content in wood net calorific value (calculated) Procedura nr LGP/42/B wyd. 4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"木材含水率","range":"(10 - 50) %"},{"name":"低位发热量","range":"(10 - 32) MJ/kg"},{"name":"（计算得出）"}],"regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 木材含水率 低位发热量 （计算得出） Procedura nr LGP/42/B wyd. 4","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具"},{"_id":"6a7d7477ec6a53014a487908","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 - 300) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 - 300) kg","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM masa paliwa (0,1 - 300) kg PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":450,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"fuel mass","range":"(0,1 - 300) kg"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC fuel mass PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料质量 PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"燃料质量","range":"(0,1 - 300) kg"}]},{"_id":"6a7d7477ec6a53014a487909","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p.A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p.A.4.2","categories":["petro"],"row_index":451,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS FLUE GAS PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 烟气参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p.A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","methodology_zh":"烟气参数："},{"_id":"6a7d7477ec6a53014a48790a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"temperatura","range":"(15 - 600) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (15 - 600) oC","reference":"PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 A.4.4.3, A.6.2","PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM temperatura (15 - 600) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM temperatura (15 - 600) oC PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“","categories":["petro"],"row_index":452,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(15 - 600) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“","parameters_zh":[{"name":"温度","range":"(15 - 600) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具"},{"_id":"6a7d7477ec6a53014a48790b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"ciśnienie","range":"(-10 - 10) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (-10 - 10) hPa","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4","PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM ciśnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM cisnienie (-10 - 10) hPa PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“","categories":["petro"],"row_index":453,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"pressure","range":"(-10 - 10) hPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“","parameters_zh":[{"name":"压力","range":"(-10 - 10) hPa"}],"test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具"},{"_id":"6a7d7477ec6a53014a48790c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"Stężenia dwutlenku węgla, tlenku węgla.","parameters":[{"name":"CO2","range":"(0,5 - 16) %"},{"name":"CO","range":"(0,0003 - 4,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2 (0,5 - 16) %\nCO (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-7:2025-10 p. 4.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3","PN-EN 16510-2-7:2025-10 p. 4.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Stężenia dwutlenku węgla, tlenku węgla.\nZakres:\nCO2 (0,5 - 16) %\nCO (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-7:2025-10 p. 4.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Stezenia dwutlenku wegla, tlenku wegla.\nZakres:\nCO2 (0,5 - 16) %\nCO (0,0003 - 4,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-7:2025-10 p. 4.3 „N“","categories":["petro"],"row_index":454,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of carbon dioxide, carbon monoxide.","parameters_en":[{"name":"CO2","range":"(0,5 - 16) %"},{"name":"CO","range":"(0,0003 - 4,0) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Concentrations of carbon dioxide, carbon monoxide. Non-dispersive infrared spectrometry (NDIR) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2 CO PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-7:2025-10 p. 4.3 „N“","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 二氧化碳、一氧化碳浓度。 非分散红外光谱法（NDIR） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 CO2 CO PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-7:2025-10 p. 4.3 „N“","parameters_zh":[{"name":"CO2","range":"(0,5 - 16) %"},{"name":"CO","range":"(0,0003 - 4,0) %"}],"technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","methodology_zh":"二氧化碳、一氧化碳浓度。"},{"_id":"6a7d7477ec6a53014a48790d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"Stężenia tlenku azotu, OGC.","parameters":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emisja CO2; CO; NO; OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda chemiluminescencji (CLD)","Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Stężenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczeń)\nMetoda chemiluminescencji (CLD); Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Stezenia tlenku azotu, OGC.\nZakres:\nNO (5 - 440) mg/m3\nOGC (3,5 - 1800) mg/m3\nEmisja CO2; CO; NO; OGC (z obliczen)\nMetoda chemiluminescencji (CLD); Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“","categories":["petro","environment"],"row_index":455,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Concentrations of nitrogen monoxide, OGC.","parameters_en":[{"name":"NO (5 - 440) mg/m3"},{"name":"OGC","range":"(3,5 - 1800) mg/m3"},{"name":"Emission of CO2; CO; NO; OGC (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Concentrations of nitrogen monoxide, OGC. Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO (5 - 440) mg/m3 OGC Emission of CO2; CO; NO; OGC (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“","technique_en":"Chemiluminescence method (CLD); Continuous flame ionization detection method (FID)","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 一氧化氮、总有机气态碳（OGC）浓度。 化学发光法（CLD）；连续火焰离子化检测法（FID） 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总有机气态碳（OGC） CO2、CO、NO、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"NO (5 - 440) mg/m3"},{"name":"总有机气态碳（OGC）","range":"(3,5 - 1800) mg/m3"},{"name":"CO2、CO、NO、OGC 排放（由计算得出）"}],"technique_zh":"化学发光法（CLD）；连续火焰离子化检测法（FID）","methodology_zh":"一氧化氮、总有机气态碳（OGC）浓度。"},{"_id":"6a7d7477ec6a53014a48790e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"Stężenie pyłów w spalinach (0,002 - 1) g/m3","parameters":[],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-7:2025-10 p. 4.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Stężenie pyłów w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Stezenie pylow w spalinach (0,002 - 1) g/m3\nMetoda grawimetryczna PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“","categories":["petro"],"row_index":456,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Dust concentration in flue gases (0,002 - 1) g/m3","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Dust concentration in flue gases (0,002 - 1) g/m3 Gravimetric method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“","technique_en":"Gravimetric method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 烟气中粉尘浓度 (0,002 - 1) g/m3 重量法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“","technique_zh":"重量法","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","methodology_zh":"烟气中粉尘浓度 (0,002 - 1) g/m3"},{"_id":"6a7d7477ec6a53014a48790f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F","PN-EN 16510-2-7:2025-10 p. 4.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“","categories":["petro"],"row_index":457,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS AIR PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 空气参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","methodology_zh":"空气参数："},{"_id":"6a7d7477ec6a53014a487910","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"temperatura","range":"(10 - 35) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 - 35) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM temperatura (10 - 35) oC PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":458,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 - 35) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 - 35) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具"},{"_id":"6a7d7477ec6a53014a487911","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":459,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"WATER PARAMETERS:","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS WATER PARAMETERS: Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 水参数： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","methodology_zh":"水参数："},{"_id":"6a7d7477ec6a53014a487912","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"temperatura","range":"(10 -1 00) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 -1 00) oC","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM temperatura (10 -1 00) oC PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM temperatura (10 -1 00) oC PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":460,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature","range":"(10 -1 00) oC"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(10 -1 00) oC"}],"test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具"},{"_id":"6a7d7477ec6a53014a487913","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"strumień objętości","range":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości (0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM strumień objętości (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM strumien objetosci (0 - 3) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":461,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"volume flow rate","range":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC volume flow rate PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 体积流量 PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"体积流量","range":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a487914","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":462,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS HEAT BALANCE (calculated): Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 热平衡（计算值）： 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d7477ec6a53014a487915","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 - 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 - 60) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM moc cieplna doprowadzona z paliwem (3 - 60) kW PN-EN 16510-1:2023-06 p.A.6.2.2","categories":["petro"],"row_index":463,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat input from fuel","range":"(3 - 60) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat input from fuel PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 燃料输入热功率 PN-EN 16510-1:2023-06 p.A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"燃料输入热功率","range":"(3 - 60) kW"}]},{"_id":"6a7d7477ec6a53014a487916","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 - 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 - 40) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM strata kominowa (5 - 40) % PN-EN 16510-1:2023-06 p.A.6.2.1.2","categories":["petro"],"row_index":464,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"stack loss","range":"(5 - 40) %"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC stack loss PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 排烟热损失 PN-EN 16510-1:2023-06 p.A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"排烟热损失","range":"(5 - 40) %"}]},{"_id":"6a7d7477ec6a53014a487917","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.3"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM straty niezupełnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM straty niezupelnego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.3","categories":["petro"],"row_index":465,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC losses due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a487918","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM strata niecałkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM strata niecalkowitego spalania PN-EN 16510-1:2023-06 p.A.6.2.1.4","categories":["petro"],"row_index":466,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC loss due to incomplete combustion PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 不完全燃烧损失 PN-EN 16510-1:2023-06 p.A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d7477ec6a53014a487919","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 - 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 - 95) %","reference":"PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.1","PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM sprawność cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM sprawnosc cieplna (20 - 95) % PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“","categories":["petro"],"row_index":467,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal efficiency","range":"(20 - 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"热效率","range":"(20 - 95) %"}]},{"_id":"6a7d7477ec6a53014a48791a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.2","PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM łączna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM laczna moc cieplna (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“","categories":["petro"],"row_index":468,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"total heat output","range":"(2 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. total heat output PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总热功率 PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"总热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a48791b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(1,5 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (1,5 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.3","PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM moc cieplna obiegu wodnego (1,5 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“","categories":["petro"],"row_index":469,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output of the water circuit","range":"(1,5 - 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"水循环回路热功率","range":"(1,5 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a48791c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(2 - 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (2 - 50) kW","reference":"PN-EN 16510-1:2023-06 p.A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.4"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM moc cieplna oddawana do pomieszczenia (2 - 50) kW PN-EN 16510-1:2023-06 p.A.6.2.4","categories":["petro"],"row_index":470,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"heat output to the room","range":"(2 - 50) kW"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC heat output to the room PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 向房间输出的热功率 PN-EN 16510-1:2023-06 p.A.6.2.4","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"向房间输出的热功率","range":"(2 - 50) kW"}]},{"_id":"6a7d7477ec6a53014a48791d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"zawartość CO (O2=13%)","range":"(0 - 4)%"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13%) (0 - 4)%","reference":"PN-EN 16510-1:2023-06 p.A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p.A.6.2.6"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM zawartość CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM zawartosc CO (O2=13%) (0 - 4)% PN-EN 16510-1:2023-06 p.A.6.2.6","categories":["petro"],"row_index":471,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"CO content (O2=13%)","range":"(0 - 4)%"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC CO content (O2=13%) PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC CO 含量（O2=13%） PN-EN 16510-1:2023-06 p.A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"CO 含量（O2=13%）","range":"(0 - 4)%"}]},{"_id":"6a7d7477ec6a53014a48791e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(1 - 100) g/s"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń)","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nstrumień masy spalin (1 - 100) g/s\n(z obliczeń) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nstrumien masy spalin (1 - 100) g/s\n(z obliczen) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“","categories":["petro"],"row_index":472,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"flue gas mass flow","range":"(1 - 100) g/s"},{"name":"(calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow (calculated) PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","parameters_zh":[{"name":"烟气质量流量","range":"(1 - 100) g/s"},{"name":"（计算得出）"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 （计算得出） PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具"},{"_id":"6a7d7477ec6a53014a48791f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"PARAMETRY TECHNICZNO-EKSPOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO-EKSPOATACYJNE:","reference":"PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 6.12","PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY TECHNICZNO-EKSPOATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM PARAMETRY TECHNICZNO-EKSPOATACYJNE: PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“","categories":["petro"],"row_index":473,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS TECHNICAL AND OPERATIONAL PARAMETERS: Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 技术与运行参数： 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","methodology_zh":"技术与运行参数："},{"_id":"6a7d7477ec6a53014a487920","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 - 200) oC"},{"name":"temperatura zasobnika paliwa","range":"(0 - 200) oC"},{"name":"temperatura uchwytów","range":"(0 - 200) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC","reference":"PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6 | PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6","PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytów (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6 | PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\ntemperatura naroznika pomiarowego i podloza (0 - 200) oC\ntemperatura zasobnika paliwa (0 - 200) oC\ntemperatura uchwytow (0 - 200) oC PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6 | PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“","categories":["petro"],"row_index":474,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 - 200) oC"},{"name":"temperature of the fuel hopper","range":"(0 - 200) oC"},{"name":"temperature of handles","range":"(0 - 200) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6 | PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6 | PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 - 200) oC"},{"name":"燃料储斗温度","range":"(0 - 200) oC"},{"name":"手柄温度","range":"(0 - 200) oC"}]},{"_id":"6a7d7477ec6a53014a487921","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 - 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 - 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6","PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM szczelność przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM szczelnosc przestrzeni wodnej (0,1 - 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“","categories":["petro"],"row_index":475,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness of the water space","range":"(0,1 - 0,6) MPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"水腔密封性","range":"(0,1 - 0,6) MPa"}]},{"_id":"6a7d7477ec6a53014a487922","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 - 120) oC"},{"name":"ciśnienie wody","range":"(0,1 - 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 - 120) oC\nciśnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 - 120) oC\ncisnienie wody (0,1 - 0,3) MPa PN-EN 16510-1:2023-06 p A.4.10.7","categories":["petro","water"],"row_index":476,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 - 120) oC"},{"name":"water pressure","range":"(0,1 - 0,3) MPa"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p A.4.10.7","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p A.4.10.7","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"出水热保护 水温","range":"(0 - 120) oC"},{"name":"水压","range":"(0,1 - 0,3) MPa"}]},{"_id":"6a7d7477ec6a53014a487923","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"szczelność (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (5 - 75) Pa; (0,2 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM szczelność (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM szczelnosc (5 - 75) Pa; (0,2 - 3) m3/h PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","categories":["petro"],"row_index":477,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness (5 - 75) Pa;","range":"(0,2 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness (5 - 75) Pa; PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 密封性 (5 - 75) Pa； PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"密封性 (5 - 75) Pa；","range":"(0,2 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a487924","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p 5.9.1"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p 5.9.1 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p 5.9.1","categories":["petro"],"row_index":478,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p 5.9.1","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p 5.9.1","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a487925","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"stała utrata powietrza","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstała utrata powietrza (1)Pa;\n(0 - 3) m3/h","reference":"PN-EN 16510-1:2023-06 Załącznik I","norm_bases":["PN-EN 16510-1:2023-06 Załącznik I"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nstała utrata powietrza (1)Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nstala utrata powietrza (1)Pa;\n(0 - 3) m3/h PN-EN 16510-1:2023-06 Zalacznik I","categories":["petro"],"row_index":479,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"constant air loss","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC constant air loss (0 - 3) m3/h PN-EN 16510-1:2023-06 Załącznik I","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 持续漏气量 PN-EN 16510-1:2023-06 Załącznik I","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"持续漏气量","range":"(1)Pa;"},{"name":"(0 - 3) m3/h"}]},{"_id":"6a7d7477ec6a53014a487926","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej","range":"(2 - 4000) W"}],"technique":"Metoda przetworników mocy","techniques":["Metoda przetworników mocy"],"computed":[],"activity":"pomiar zużycia energii elektrycznej (2 - 4000) W\nMetoda przetworników mocy","reference":"PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“","norm_bases":["PN-EN 16510-1:2023-06 p 6.11","PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM pomiar zużycia energii elektrycznej (2 - 4000) W\nMetoda przetworników mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM pomiar zuzycia energii elektrycznej (2 - 4000) W\nMetoda przetwornikow mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“","categories":["petro"],"row_index":480,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"measurement of electrical energy consumption","range":"(2 - 4000) W"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Power transducer method Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of electrical energy consumption PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“","technique_en":"Power transducer method","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 功率传感器法 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 电能消耗测量 PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"电能消耗测量","range":"(2 - 4000) W"}],"technique_zh":"功率传感器法"},{"_id":"6a7d7477ec6a53014a487927","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.4","PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“","categories":["petro"],"row_index":481,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"temperature safety test"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature safety test PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度安全性试验 PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d7477ec6a53014a487928","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"działanie ogranicznika temperatury"}],"technique":null,"techniques":[],"computed":[],"activity":"działanie ogranicznika temperatury","reference":"PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7","PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM działanie ogranicznika temperatury PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM dzialanie ogranicznika temperatury PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“","categories":["petro"],"row_index":482,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"operation of the temperature limiter"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. operation of the temperature limiter PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具"},{"_id":"6a7d7477ec6a53014a487929","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"zanik zasilania elektrycznego","range":"(0 - 110) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"zanik zasilania elektrycznego (0 - 110) oC","reference":"PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7","PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM zanik zasilania elektrycznego (0 - 110) oC PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM zanik zasilania elektrycznego (0 - 110) oC PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“","categories":["petro"],"row_index":483,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss of electrical power supply","range":"(0 - 110) oC"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. loss of electrical power supply PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 供电中断 PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"供电中断","range":"(0 - 110) oC"}]},{"_id":"6a7d7477ec6a53014a48792a","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"zanik odbioru ciepła (0 - 110) oC,","range":"(0 - 5) %"},{"name":"CO"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzanik odbioru ciepła (0 - 110) oC, (0 - 5) %\nCO","reference":"PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.7","PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nzanik odbioru ciepła (0 - 110) oC, (0 - 5) %\nCO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nzanik odbioru ciepla (0 - 110) oC, (0 - 5) %\nCO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“","categories":["petro"],"row_index":484,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"loss of heat removal (0 - 110) oC,","range":"(0 - 5) %"},{"name":"CO"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. loss of heat removal (0 - 110) oC, CO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 散热中断 (0 - 110) oC， CO PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“","parameters_zh":[{"name":"散热中断 (0 - 110) oC，","range":"(0 - 5) %"},{"name":"CO"}],"test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具"},{"_id":"6a7d7477ec6a53014a48792b","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"nośność"}],"technique":null,"techniques":[],"computed":[],"activity":"nośność","reference":"PN-EN 16510-1:2023-06 p A.4.10.2","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.2"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 1999/471/WE","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM nośność PN-EN 16510-1:2023-06 p A.4.10.2 MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM nosnosc PN-EN 16510-1:2023-06 p A.4.10.2","categories":["petro"],"row_index":485,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"load-bearing capacity"}],"regulatory_area_en":"Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC load-bearing capacity PN-EN 16510-1:2023-06 p A.4.10.2","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 符合性评定，依据欧洲议会和理事会条例（EU）第 305/2011 号（CPR），欧盟委员会决定：1999/471/EC 承载力 PN-EN 16510-1:2023-06 p A.4.10.2","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"承载力"}]},{"_id":"6a7d7477ec6a53014a48792c","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"},{"name":"sezonowa efektywność ogrzewania pomieszczeń (z obliczeń)"},{"name":"współczynnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“","norm_bases":["PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"MIESZKANIOWE URZĄDZENIA SPALAJĄCE PALIWO STAŁE - URZĄDZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“ MIESZKANIOWE URZADZENIA SPALAJACE PALIWO STALE - URZADZENIA WIELOFUNKCYJNE OPALANE DREWNEM I PELETEM Zakres:\nefektywnosc (z obliczen)\nsezonowa efektywnosc ogrzewania pomieszczen (z obliczen)\nwspolczynnik efektywnosci energetycznej EEI (z obliczen) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“","categories":["petro"],"row_index":486,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"efficiency (calculated)"},{"name":"seasonal space heating efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Boiler and Heating Equipment Testing Laboratory „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“","test_object_en":"RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS","lab_section_zh":"锅炉与供暖设备检测实验室","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具 锅炉与供暖设备检测实验室 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 效率（由计算得出） 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“","test_object_zh":"民用固体燃料燃烧器具 — 燃烧木材与颗粒的多功能器具","parameters_zh":[{"name":"效率（由计算得出）"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}]},{"_id":"6a7d7477ec6a53014a48792d","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"Rodzaj działalności:","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"},{"name":"sezonowa efektywność ogrzewania pomieszczeń (z obliczeń)"},{"name":"współczynnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń)","reference":"Dokument odniesienia:","norm_bases":["Dokument odniesienia:"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Laboratorium spełnia wymagania określone w Rozporządzeniu Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, ppkt.3 rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"Rodzaj działalności: Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność ogrzewania pomieszczeń (z obliczeń)\nwspółczynnik efektywności energetycznej EEI (z obliczeń) Dokument odniesienia: Rodzaj dzialalnosci: Zakres:\nefektywnosc (z obliczen)\nsezonowa efektywnosc ogrzewania pomieszczen (z obliczen)\nwspolczynnik efektywnosci energetycznej EEI (z obliczen) Dokument odniesienia:","categories":["other"],"row_index":487,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","parameters_en":[{"name":"efficiency (calculated)"},{"name":"seasonal space heating efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope.","search_en":"Type of activity: Boiler and Heating Equipment Testing Laboratory The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope. efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) Dokument odniesienia:","test_object_en":"Type of activity:","lab_section_zh":"锅炉与供暖设备检测实验室","search_zh":"活动类别： 锅炉与供暖设备检测实验室 本实验室在上述范围内符合欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例对检测实验室所规定的活动要求（第305/2011号条例附件V第3款）。 效率（由计算得出） 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） Dokument odniesienia:","parameters_zh":[{"name":"效率（由计算得出）"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}],"regulatory_area_zh":"本实验室在上述范围内符合欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例对检测实验室所规定的活动要求（第305/2011号条例附件V第3款）。","test_object_zh":"活动类别："},{"_id":"6a7d7477ec6a53014a48792e","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"OCENA WŁAŚCIWOŚCI, UŻYTKOWYCH NA PODSTAWIE BADAŃ, OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DOKUMENTACJI WYROBU BUDOWLANEGO (System 3)","methodology":"Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG","reference":"Dokument odniesienia:","norm_bases":["Dokument odniesienia:"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Laboratorium spełnia wymagania określone w Rozporządzeniu Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, ppkt.3 rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"OCENA WŁAŚCIWOŚCI, UŻYTKOWYCH NA PODSTAWIE BADAŃ, OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DOKUMENTACJI WYROBU BUDOWLANEGO (System 3) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG Dokument odniesienia: OCENA WLASCIWOSCI, UZYTKOWYCH NA PODSTAWIE BADAN, OBLICZEN, TABELARYCZNYCH WARTOSCI LUB OPISOWEJ DOKUMENTACJI WYROBU BUDOWLANEGO (System 3) Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiajace zharmonizowane warunki wprowadzania do obrotu wyrobow budowlanych i uchylajace dyrektywe Rady 89/106/EWG Dokument odniesienia:","categories":["construction"],"row_index":488,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC","regulatory_area_en":"The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope.","search_en":"ASSESSMENT OF PERFORMANCE, ON THE BASIS OF TESTING, CALCULATION, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3) Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC Boiler and Heating Equipment Testing Laboratory The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope. Dokument odniesienia:","test_object_en":"ASSESSMENT OF PERFORMANCE, ON THE BASIS OF TESTING, CALCULATION, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3)","lab_section_zh":"锅炉与供暖设备检测实验室","search_zh":"欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例，该条例规定了建筑制品上市的统一条件并废止理事会89/106/EEC指令 锅炉与供暖设备检测实验室 本实验室在上述范围内符合欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例对检测实验室所规定的活动要求（第305/2011号条例附件V第3款）。 Dokument odniesienia:","methodology_zh":"欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例，该条例规定了建筑制品上市的统一条件并废止理事会89/106/EEC指令","regulatory_area_zh":"本实验室在上述范围内符合欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例对检测实验室所规定的活动要求（第305/2011号条例附件V第3款）。"},{"_id":"6a7d7477ec6a53014a48792f","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"Numer decyzji Komisji","methodology":"Wyrób(y)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wyrób(y)","reference":"Zharmonizowane specyfikacje techniczne","norm_bases":["Zharmonizowane specyfikacje techniczne"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Laboratorium spełnia wymagania określone w Rozporządzeniu Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, ppkt.3 rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"Numer decyzji Komisji Wyrób(y) Zharmonizowane specyfikacje techniczne Numer decyzji Komisji Wyrob(y) Zharmonizowane specyfikacje techniczne","categories":["other"],"row_index":489,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Product(s)","regulatory_area_en":"The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope.","search_en":"Commission decision number Product(s) Boiler and Heating Equipment Testing Laboratory The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope. Zharmonizowane specyfikacje techniczne","test_object_en":"Commission decision number","lab_section_zh":"锅炉与供暖设备检测实验室","search_zh":"委员会决定编号 制品 锅炉与供暖设备检测实验室 本实验室在上述范围内符合欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例对检测实验室所规定的活动要求（第305/2011号条例附件V第3款）。 Zharmonizowane specyfikacje techniczne","methodology_zh":"制品","test_object_zh":"委员会决定编号","regulatory_area_zh":"本实验室在上述范围内符合欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例对检测实验室所规定的活动要求（第305/2011号条例附件V第3款）。"},{"_id":"6a7d7477ec6a53014a487930","lab_id":"69ad52a3de79e566650fb111","country":"PL","accr_number":"AB 087","accr_body":"PCA","test_object":"99/471/WE","methodology":"Urządzenia do ogrzewania pomieszczeń na paliwa stałe i ciekłe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Urządzenia do ogrzewania pomieszczeń na paliwa stałe i ciekłe","reference":"EN 16510-2-1:2022 | EN 16510-2-2:2022 | EN 16510-2-3:2022 | EN 16510-2-6:2022 | EN 16510-2-5:2025 | EN 16510-2-7:2025","norm_bases":["EN 16510-2-1:2022","EN 16510-2-2:2022","EN 16510-2-3:2022","EN 16510-2-6:2022","EN 16510-2-5:2025","EN 16510-2-7:2025"],"lab_section":"Laboratorium Badań Kotłów i Urządzeń Grzewczych","lab_address":null,"regulatory_area":"Laboratorium spełnia wymagania określone w Rozporządzeniu Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, ppkt.3 rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"99/471/WE Urządzenia do ogrzewania pomieszczeń na paliwa stałe i ciekłe EN 16510-2-1:2022 | EN 16510-2-2:2022 | EN 16510-2-3:2022 | EN 16510-2-6:2022 | EN 16510-2-5:2025 | EN 16510-2-7:2025 99/471/WE Urzadzenia do ogrzewania pomieszczen na paliwa stale i ciekle EN 16510-2-1:2022 | EN 16510-2-2:2022 | EN 16510-2-3:2022 | EN 16510-2-6:2022 | EN 16510-2-5:2025 | EN 16510-2-7:2025","categories":["petro"],"row_index":490,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Boiler and Heating Equipment Testing Laboratory","methodology_en":"Space heaters fired with solid and liquid fuels","regulatory_area_en":"The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope.","search_en":"99/471/WE Space heaters fired with solid and liquid fuels Boiler and Heating Equipment Testing Laboratory The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope. EN 16510-2-1:2022 | EN 16510-2-2:2022 | EN 16510-2-3:2022 | EN 16510-2-6:2022 | EN 16510-2-5:2025 | EN 16510-2-7:2025","test_object_en":"99/471/WE","lab_section_zh":"锅炉与供暖设备检测实验室","search_zh":"固体与液体燃料房间供暖器具 锅炉与供暖设备检测实验室 本实验室在上述范围内符合欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例对检测实验室所规定的活动要求（第305/2011号条例附件V第3款）。 EN 16510-2-1:2022 | EN 16510-2-2:2022 | EN 16510-2-3:2022 | EN 16510-2-6:2022 | EN 16510-2-5:2025 | EN 16510-2-7:2025","methodology_zh":"固体与液体燃料房间供暖器具","regulatory_area_zh":"本实验室在上述范围内符合欧洲议会与理事会2011年3月9日第305/2011号（欧盟）条例对检测实验室所规定的活动要求（第305/2011号条例附件V第3款）。"}],"has_pdf":true}