🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 085 • Warszawa, Poland • 100 methods

Water & wastewaterEnvironmentElectronics & EMC

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 085 (Warszawa, Poland). Its accreditation scope covers 100 test methods in the following areas: Water & wastewater, Environment, Electronics & EMC. Test objects include: Water Wastewater, Water, Sewage sludge Waste O): code 19 08 05, Soil.

At a glance

  • Accreditation number: PCA AB 085
  • Methods in scope: 100
  • Types of test objects: 13
  • City: Warszawa, Poland
Accreditation number
AB 085
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W ŁODZI, ul. Lipowa 16
City
Warszawa, Poland

What this laboratory tests (13)

Accreditation scope — test methods (100)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Chromium (Cr+6) concentration Range: (0,003 – 0,50) mg/l Spectrophotometric method PN-EN ISO 18412:2007
2 Water Dissolved phosphate concentration Range: (0,03 – 50,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt. 4 + Ap1:2010+Ap2:2010
3 Water Mercury concentration: Range: (0,0200 – 0,300) µg/l Cold vapour atomic spectrometry method with fluorescence detection (CVAFS) PN-EN ISO 17852:2009
4 Water Cyanide concentration Range: Total cyanides (0,008 – 0,10) mg/l Free cyanides (0,008 – 0,10) mg/l Flow analysis method with spectrophotometric detection (CFA) PN-EN ISO 14403-2:2012
5 Water Element concentrations Range: Antimony (0,10 – 100) µg/l Arsenic (1,00 – 100) µg/l Barium (1,00 – 1000) µg/l Beryllium (0,10 – 100) µg/l Boron (5,00 – 10000) µg/l Total chromium (1,00 – 100) µg/l Tin (1,00 – 100) µg/l Zinc (1,00 – 1000) µg/l Aluminium (5,00 – 10000) µg/l Cadmium (0,020 – 100) µg/l Cobalt (1,00 – 100) µg/l Magnesium (0,050 – 100) mg/l Manganese (1,00 – 10000) µg/l Copper (1,00 – 1000) µg/l Molybdenum (1,00 – 100) µg/l Nickel (1,00 – 1000) µg/l Lead (0,30 – 100) µg/l Potassium (0,050 – 100) mg/l Selenium (5,00 – 100) µg/l Sodium (0,050 – 100) mg/l Silver (1,00 – 100) µg/l Thallium (0,10 – 100) µg/l Vanadium (1,00 – 100) µg/l Calcium (0,10 – 200) mg/l Iron (5,00 – 10000) µg/l Titanium (1,00 – 100) µg/l Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
6 Water Concentration of polycyclic aromatic hydrocarbons Range: Benzo(a)pyrene (0,00012 – 2,0) µg/l Benzo(b)fluoranthene (0,0013 – 2,0) µg/l Benzo(k)fluoranthene (0,0013 – 2,0) µg/l Anthracene (0,003 – 2,0) µg/l Fluoranthene (0,002 – 2,0) µg/l Naphthalene (0,002 – 2,0) µg/l Benzo(g,h,i)perylene (0,0012 – 2,0) µg/l Indeno(1,2,3-cd)pyrene (0,0011 – 2,0) µg/l Dibenzo(a,h)anthracene (0,003 – 2,0) µg/l High performance liquid chromatography method with fluorescence detection (HPLC–FLD) Sum of PAH (calculated) PN-EN ISO 17993:2005
7 Wastewater Concentration of polycyclic aromatic hydrocarbons Range: Benzo(a)pyrene (0,003 – 2,0) µg/l Benzo(b)fluoranthene (0,003 – 2,0) µg/l Benzo(k)fluoranthene (0,003 – 2,0) µg/l Benzo(g,h,i)perylene (0,003 – 2,0) µg/l Indeno(1,2,3-cd)pyrene (0,003 – 2,0) µg/l Dibenzo(a,h)anthracene (0,003 – 2,0) µg/l High performance liquid chromatography method with fluorescence detection (HPLC–FLD) Sum of PAH (calculated) PN-EN ISO 17993:2005
8 Wastewater Mercury concentration Range: (0,000200 – 1,00) mg/l Atomic absorption spectrometry with amalgamation technique EPA METHOD 7473 02.2007
9 Wastewater Element concentrations Range: Antimony (0,0100 – 10,0) mg/l Arsenic (0,0100 – 10,0) mg/l Barium (0,0100 – 10,0) mg/l Beryllium (0,0100 – 10,0) mg/l Boron (0,0500 – 10,0) mg/l Total chromium (0,0100 – 10,0) mg/l Tin (0,0100 – 10,0) mg/l Zinc (0,0500 – 10,0) mg/l Aluminium (0,100 – 10,0) mg/l Cadmium (0,0010 – 10,0) mg/l Cobalt (0,0100 – 10,0) mg/l Manganese (0,0100 – 10,0) mg/l Copper (0,0100 – 10,0) mg/l Molybdenum (0,0100 – 10,0) mg/l Nickel (0,0100 – 10,0) mg/l Lead (0,0100 – 10,0) mg/l Selenium (0,0500 – 10,0) mg/l Silver (0,0100 – 10,0) mg/l Thallium (0,0100 – 10,0) mg/l Vanadium (0,0100 – 10,0) mg/l Iron (0,100 – 10,0) mg/l Titanium (0,0100 – 10,0) mg/l Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
10 Water Wastewater Total organic carbon (TOC) concentration Range: (1,00 – 500) mg/l Infrared range spectrometry method IR PN-EN 1484:1999
11 Water Wastewater Nitrite nitrogen concentration − N NO2 Range: (0,004 – 2,0) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
12 Water Wastewater Nitrite concentration – NO 2 (calculated)
13 Water Wastewater Kjeldahl nitrogen concentration Range: (0,5 – 50,0) mg/l Titrimetric method PN-EN 25663:2001
14 Water Wastewater Total nitrogen concentration Sum of N , N and N kjeld NO2 NO3 (calculated) PB-21/LO, wydanie 3 z dnia 01.08.2025 r.
15 Water Wastewater Phosphate concentration Range: (0,03 – 20,0) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
16 Water Wastewater Phosphate phosphorus concentration – P (calculated)
17 Water Wastewater Total suspended solids Range: (2 – 1000) mg/l Gravimetric method PN-EN 872:2007 + Ap1:2007
18 Water Wastewater Chromium (Cr+6) concentration Range: (0,02 – 2,0) mg/l Spectrophotometric method PN-77/C-04604/08
19 Water Wastewater Anion concentrations: Range: Chlorides (3,5 – 500) mg/l Sulfates (2,0 – 500) mg/l Nitrites (0,25 – 20,0) mg/l Nitrite nitrogen concentration – NNO2 (calculated) Nitrates (1,7 – 100) mg/l Nitrate nitrogen concentration – NNO3 (calculated) Fluorides (0,15 – 10,0) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012
20 Water Wastewater Total phosphorus concentration Range: (0,05 – 25,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
21 Water Wastewater Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
22 Water Wastewater Biochemical oxygen demand - BOD 5 Range: (0,50 – 8,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
23 Water Wastewater Chemical oxygen demand COD-Cr Range: (10,0 – 1000) mg/l Spectrophotometric method PN-ISO 15705:2005
24 Water Wastewater Mineral oil index Range: (0,06 – 500) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-ISO 9377-2:2003
25 Soil Mercury content Range: (0,0300 – 2,00) mg/kg Atomic absorption spectrometry with amalgamation technique EPA METHOD 7473 02.2007
26 Soil Content of elements Range: Arsenic (0,2 – 400) mg/kg Barium (2,0 – 400) mg/kg Total chromium (0,2 – 400) mg/kg Zinc (2,0 – 400) mg/kg Cadmium (0,2 – 400) mg/kg Cobalt (0,2 – 400) mg/kg Copper (2,0 – 400) mg/kg Molybdenum (0,2 – 400) mg/kg Nickel (0,2 – 400) mg/kg Lead (0,2 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) method PN-EN 16173:2012 PN-EN 16171:2017-02
27 Soil Tin content Range: (2,0 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 16174:2012 PN-EN 16171:2017-02
28 Sewage sludge Waste O): code 19 08 05 Mercury content Range: (0,0300 – 2,00) mg/kg Atomic absorption spectrometry with amalgamation technique EPA METHOD 7473 02.2007
29 Sewage sludge Waste O): code 19 08 05 Content of elements Range: Arsenic (0,2 – 400) mg/kg Total chromium (0,2 – 400) mg/kg Zinc (2,0 – 400) mg/kg Cadmium (0,2 – 400) mg/kg Copper (2,0 – 400) mg/kg Nickel (0,2 – 400) mg/kg Lead (0,2 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) method PN-EN 16171:2017-02
30 Sewage sludge Waste O): code 19 08 05 Calcium content Range: (0,2 – 200) g/kg (0,02 – 20,0) % Magnesium content Range: (0,02 – 20,0) g/kg (0,002 – 2,0) % Inductively coupled plasma mass spectrometry (ICP-MS) method PN-EN 16171:2017-02
31 Water Biochemical oxygen demand - BOD 5 Range: (3,0 – 200) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
32 Water Permanganate index Range: (0,5 – 100) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001
33 Water Colour Range: (5 – 70) mg/l Pt Visual method PN-EN ISO 7887:2012 metoda D
34 Water Total phosphorus concentration Range: (0,02 – 4,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010
35 Wastewater Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
36 Wastewater Total phosphorus concentration Range: (0,02 – 400) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
37 Water Wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
38 Water Wastewater Total nitrogen concentration (calculated) PB-28/LO, wydanie 3 z dnia 01.08.2025 r.
39 Water Wastewater Concentration of substances extractable with petroleum ether Range: (1,0 – 2500) mg/l Gravimetric method PB-27/LO, wydanie 3 z dnia 01.08.2025 r.
40 Water Wastewater Total suspended solids Range: (2 – 2000) mg/l Gravimetric method PN-EN 872:2007 +Ap1:2007
41 Water Wastewater Phosphate concentration Range: (0,05 – 12) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
42 Water Wastewater Phosphate concentration Range: (0,06 – 10) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
43 Water Wastewater Nitrate nitrogen concentration Range: (0,30 – 50) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
44 Water Wastewater Nitrate concentration – NO 3 (calculated)
45 Water Wastewater Ammonium nitrogen concentration Range: (0,10 – 10) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11732:2007
46 Water Wastewater Concentration of ammonium ion, ammonia (calculated)
47 Water Wastewater Nitrite nitrogen concentration Range: (0,007 – 1,0) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
48 Water Wastewater Un-ionised ammonia concentration (calculated) PB-29/LO, wydanie 3 z dnia 01.08.2025 r.
49 Water Wastewater Ammonium nitrogen concentration Range: (0,040 – 100) mg/l Spectrophotometric method PN-ISO 7150-1:2002
50 Water Wastewater Kjeldahl nitrogen concentration Range: (0,5 – 250) mg/l Spectrophotometric method PN-EN 25663:2001
51 Water Wastewater Chemical oxygen demand - COD-Cr Range: (30,0 – 6000) mg/l O 2 Titrimetric method PN-ISO 6060:2006
52 Water Wastewater Chemical oxygen demand - COD-Cr Range: (9,0 – 150) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
53 Water Wastewater Phenol concentration (phenol index) Range: (0,0015 – 5,00) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 14402:2004
54 Soil, waste O): code 19 08 05 Kjeldahl nitrogen content Range: (0,12 – 64) g/kg Spectrophotometric method PB-35/LO, wydanie 3 z dnia 01.08.2025 r.
55 Soil Content of organic substances, mineral substances Range: (100 – 850) g/kg (10 – 85) % Gravimetric method PB-34/LO, wydanie 3 z dnia 01.08.2025 r.
56 Soil Dry matter content / water content Range: (10 – 95) % Gravimetric method PN-ISO 11465:1999
57 Soil pH – in KCl, pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09
58 Sewage sludge, waste O): code 19 08 05 pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09
59 Sewage sludge, waste O): code 19 08 05 Kjeldahl nitrogen content Range: (3,0 – 64) g/kg (0,3 – 6,4) % Spectrophotometric method PN-EN 13342:2002
60 Sewage sludge, waste O): code 19 08 05 Dry matter content / water content Range:(10 – 90) % (100 – 900) g/kg Gravimetric method PN-EN 12880:2004
61 Sewage sludge, waste O): code 19 08 05 Total phosphorus content Range: (1,0 – 20,0) g/kg (0,1 – 2,0) % Spectrophotometric method PN-EN 14672:2006 PN-EN ISO 6878:2006
62 Sewage sludge, waste O): code 19 08 05 Loss on ignition (organic matter content) Range: (5,0 – 90,0)% Gravimetric method PN-EN 15935:2022-01
63 Sewage sludge, waste O): code 19 08 05 Ammonium nitrogen content Range: (0,40 – 20,0) g/kg (0,04 – 2,00) % Spectrophotometric method PB-42/LO, wydanie 2 z dnia 01.08.2025 r.
64 Water Colour Range: (5 – 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 Metoda C
65 Water Wastewater Ammonium nitrogen concentration Range: (0,030 – 100) mg/l Spectrophotometric method PN-ISO 7150-1:2002
66 Water Wastewater Nitrite nitrogen concentration Range: (0,001 – 5) mg/l Spectrophotometric method PN-EN 26777:1999
67 Water Wastewater Kjeldahl nitrogen concentration Range: (1 – 150) mg/l Titrimetric method PN-EN 25663:2001
68 Water Wastewater Total nitrogen concentration (calculated) PB-08/LO, wydanie 3 z dnia 01.08.2025 r.
69 Water Wastewater Total phosphorus concentration Range: (0,005 – 50) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt 7
70 Water Wastewater Dissolved orthophosphate concentration Range: (0,005 – 50,0) mg/l P Spectrophotometric method PN-EN ISO 6878:2006 pkt. 4 +Ap2:2010
71 Water Wastewater Total suspended solids Range: 2 mg/l – 3 g/l Gravimetric method PN-EN 872:2007 + Ap1:2007
72 Water Wastewater Anionic surfactants (MBAS index) Range: (0,06 – 5) mg/l Spectrophotometric method PN-EN 903:2002
73 Water Wastewater Chemical oxygen demand COD-Cr Range: 7,5 mg/l O - 5 g/l O 2 2 Spectrophotometric method PN-ISO 15705:2005
74 Soil Dry matter Range: (60,0 – 99,9)% Water content Range: (0,1 – 40,0)% Gravimetric method PN-ISO 11465:1999
75 Soil pH - in KCl Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09
76 Sewage sludge Waste O): code 19 08 05 Total phosphorus content Range: (0,1 – 2,5) % (1,0 – 25) g/kg Spectrophotometric method PN-EN14672:2006 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
77 Sewage sludge Waste O): code 19 08 05 Ammonium nitrogen content Range: (0,050 – 1,5) % Spectrophotometric method PB-14/LO, wydanie 4 z dnia 01.08.2025 r.
78 Sewage sludge Waste O): code 19 08 05 Kjeldahl nitrogen content Range: (0,01 – 5)% Spectrophotometric method PN-EN 13342:2002
79 Sewage sludge Waste O): code 19 08 05 pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09
80 Sewage sludge Waste O): code 19 08 05 Dry residue, water content Range: (5 – 95)% Gravimetric method PN-EN 12880:2004
81 Sewage sludge Waste O): code 19 08 05 Loss on ignition of dry matter (LOI) / residue on ignition Range: (5,0 – 90,0)% Gravimetric method PN-EN 15935:2022-01
82 Sewage sludge Waste O): code 19 08 05 Presence and number of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Range: from 10 ATT eggs/kg d.m. Microscopic method PB-19/LO, wydanie 3 z dnia 01.08.2025 r.
83 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (26 - 135) dB Direct measurement method nr 7 | enia Ministra Klimatu i Środowiska z dn. 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punku F
84 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
85 General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (26 - 135) dB Direct measurement method Nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023
86 General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
87 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (26 - 135) dB Direct measurement method Nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U.2011 nr 140 | nr 288 | eniem punktu H
88 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
89 Water Sampling for physical and chemical testing Manual method Temperature of water/of the water sample taken Range: (0,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584
90 Wastewater Sampling for physical and chemical testing Manual/ automatic method Temperature of wastewater/of the wastewater sample taken Range: (0,0 – 50,0) °C PN-ISO 5667-10:2021:11 PN-77/C-04584
91 Water Wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
92 Water Wastewater Electrical conductivity Range: (10 - 20000) μS/cm Conductometric method PN-EN 27888:1999
93 Water Wastewater Dissolved oxygen concentration Range: (0,2 – 15,0) mg/l Electrochemical method PN-EN ISO 5814:2013-04
94 Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 PN-ISO 10381-5:2009
95 Sewage sludge, Waste O): code 19 08 05 Sampling for physical, chemical and biological testing PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3
96 Environment - electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: - in the frequency range 50 Hz Range: 1,0 V/m – 50 kV/m Direct measurement method enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022
97 Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: - in the frequency range 50 Hz Range 0,1 µT – 10 mT Direct measurement method
98 Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength: - in the frequency range 50 Hz (calculated)
99 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: - in the frequency range from 10 MHz to 3 GHz Range: (0,3 – 300) V/m - in the frequency range from 80 MHz to 60 GHz Range: (0,8 – 300) V/m Direct measurement method enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022
100 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: - in the frequency range from 10 MHz to 60 GHz (calculated) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022

Reference standards (70)

EPA METHOD 7473 02.2007
Nr 3
Nr 8
PB-08/LO, wydanie 3 z dnia 01.08.2025 r.
PB-14/LO, wydanie 4 z dnia 01.08.2025 r.
PB-19/LO, wydanie 3 z dnia 01.08.2025 r.
PB-21/LO, wydanie 3 z dnia 01.08.2025 r.
PB-27/LO, wydanie 3 z dnia 01.08.2025 r.
PB-28/LO, wydanie 3 z dnia 01.08.2025 r.
PB-29/LO, wydanie 3 z dnia 01.08.2025 r.
PB-34/LO, wydanie 3 z dnia 01.08.2025 r.
PB-35/LO, wydanie 3 z dnia 01.08.2025 r.
PB-42/LO, wydanie 2 z dnia 01.08.2025 r.
PN-77/C-04604/08
PN-EN 12880:2004
PN-EN 13342:2002
PN-EN 14672:2006 PN-EN ISO 6878:2006
PN-EN 1484:1999
PN-EN 15935:2022-01
PN-EN 16171:2017-02
PN-EN 16173:2012 PN-EN 16171:2017-02
PN-EN 16174:2012 PN-EN 16171:2017-02
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 + Ap1:2007
PN-EN 872:2007 +Ap1:2007
PN-EN 903:2002
PN-EN ISO 10304-1:2009 +AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11732:2007
PN-EN ISO 13395:2001
PN-EN ISO 14402:2004
PN-EN ISO 14403-2:2012
PN-EN ISO 15681-2:2019-02
PN-EN ISO 17294-2:2024-04
PN-EN ISO 17852:2009
PN-EN ISO 17993:2005
PN-EN ISO 18412:2007
PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3
PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 7
PN-EN ISO 6878:2006 pkt. 4 + Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt. 4 +Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7887:2012 Metoda C
PN-EN ISO 7887:2012 metoda D
PN-EN ISO 8467:2001
PN-EN14672:2006 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-ISO 10381-4:2007 PN-ISO 10381-5:2009
PN-ISO 11465:1999
PN-ISO 15705:2005
PN-ISO 5667-10:2021:11 PN-77/C-04584
PN-ISO 6060:2006
PN-ISO 7150-1:2002
PN-ISO 9377-2:2003
enia Ministra Klimatu i Środowiska z dn. 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punku F
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023
enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022
enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U.2011 nr 140
eniem punktu H
nr 288
nr 7