{"lab":{"_id":"69ad52a3de79e566650fb10f","accr_number":"AB 085","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W ŁODZI, ul. Lipowa 16","categories":["water","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":100,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_085.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w łodzi, ul. lipowa 16 water other materials petro food environment pharma automotive metrology electronics","status":"active","updated_at":"2026-03-08T14:50:10.207Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:10.207Z","parse_date":"2026-07-17T16:19:12.624Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/gios/centralne-laboratorium-badawcze","fields_of_testing":[{"codes":"B/32/P","pl":"Badania biologiczne i pobieranie próbek osadów, odpadów","en":"Biological tests and sampling of sediments and waste"},{"codes":"C/28/P, C/30/P, C/31/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, gleby, osadów, odpadów","en":"Chemical tests and sampling of water, sewage, soil, sediments, waste"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field)"},{"codes":"N/28/P, N/30/P, N/31/P, N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, gleby, osadów, odpadów","en":"Tests of physical properties and sampling of water, sewage, soil, sediments, waste"}],"issue":{"no":"24","date":"21.10.2025"},"map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":81,"environment":38,"materials":4,"petro":1},"category_scores":{"water":52.91,"environment":11.65,"materials":0.13,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a5a56009af9f73f38253bcc","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chromu (Cr+6) Zakres: (0,003 – 0,50) mg/l Metoda spektrofotometryczna","methodology_en":"Chromium (Cr+6) concentration Range: (0,003 – 0,50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu (Cr+6) Zakres: (0,003 – 0,50) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chromu (Cr+6) Zakres: (0,003 – 0,50) mg/l Metoda spektrofotometryczna PN-EN ISO 18412:2007 Woda Stezenie chromu (Cr+6) Zakres: (0,003 – 0,50) mg/l Metoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Chromium (Cr+6) concentration Range: (0,003 – 0,50) mg/l Spectrophotometric method PN-EN ISO 18412:2007","search_zh":"水 PN-EN ISO 18412:2007","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253bcd","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie fosforanów rozpuszczonych Zakres: (0,03 – 50,0) mg/l Metoda spektrofotometryczna","methodology_en":"Dissolved phosphate concentration Range: (0,03 – 50,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforanów rozpuszczonych Zakres: (0,03 – 50,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 4 + Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 4 + Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie fosforanów rozpuszczonych Zakres: (0,03 – 50,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 + Ap1:2010+Ap2:2010 Woda Stezenie fosforanow rozpuszczonych Zakres: (0,03 – 50,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 + Ap1:2010+Ap2:2010","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Dissolved phosphate concentration Range: (0,03 – 50,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt. 4 + Ap1:2010+Ap2:2010","search_zh":"水 PN-EN ISO 6878:2006 pkt. 4 + Ap1:2010+Ap2:2010","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253bce","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci: Zakres: (0,0200 – 0,300) µg/l Metoda spektrometrii atomowej z generacją zimnych par i detekcją fluorescencyjną (CVAFS)","methodology_en":"Mercury concentration: Range: (0,0200 – 0,300) µg/l Cold vapour atomic spectrometry method with fluorescence detection (CVAFS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci: Zakres: (0,0200 – 0,300) µg/l Metoda spektrometrii atomowej z generacją zimnych par i detekcją fluorescencyjną (CVAFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci: Zakres: (0,0200 – 0,300) µg/l Metoda spektrometrii atomowej z generacją zimnych par i detekcją fluorescencyjną (CVAFS) PN-EN ISO 17852:2009 Woda Stezenie rteci: Zakres: (0,0200 – 0,300) µg/l Metoda spektrometrii atomowej z generacja zimnych par i detekcja fluorescencyjna (CVAFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Mercury concentration: Range: (0,0200 – 0,300) µg/l Cold vapour atomic spectrometry method with fluorescence detection (CVAFS) PN-EN ISO 17852:2009","search_zh":"水 PN-EN ISO 17852:2009","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253bcf","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie cyjanków Zakres: Cyjanki ogólne (0,008 – 0,10) mg/l Cyjanki wolne (0,008 – 0,10) mg/l Metoda analizy przepływowej z detekcją spektrofotometryczną (CFA)","methodology_en":"Cyanide concentration Range: Total cyanides (0,008 – 0,10) mg/l Free cyanides (0,008 – 0,10) mg/l Flow analysis method with spectrophotometric detection (CFA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków Zakres: Cyjanki ogólne (0,008 – 0,10) mg/l Cyjanki wolne (0,008 – 0,10) mg/l Metoda analizy przepływowej z detekcją spektrofotometryczną (CFA)","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie cyjanków Zakres: Cyjanki ogólne (0,008 – 0,10) mg/l Cyjanki wolne (0,008 – 0,10) mg/l Metoda analizy przepływowej z detekcją spektrofotometryczną (CFA) PN-EN ISO 14403-2:2012 Woda Stezenie cyjankow Zakres: Cyjanki ogolne (0,008 – 0,10) mg/l Cyjanki wolne (0,008 – 0,10) mg/l Metoda analizy przeplywowej z detekcja spektrofotometryczna (CFA) PN-EN ISO 14403-2:2012","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Cyanide concentration Range: Total cyanides (0,008 – 0,10) mg/l Free cyanides (0,008 – 0,10) mg/l Flow analysis method with spectrophotometric detection (CFA) PN-EN ISO 14403-2:2012","search_zh":"水 PN-EN ISO 14403-2:2012","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253bd0","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie pierwiastków Zakres: Antymon (0,10 – 100) µg/l Arsen (1,00 – 100) µg/l Bar (1,00 – 1000) µg/l Beryl (0,10 – 100) µg/l Bor (5,00 – 10000) µg/l Chrom ogólny (1,00 – 100) µg/l Cyna (1,00 – 100) µg/l Cynk (1,00 – 1000) µg/l Glin (5,00 – 10000) µg/l Kadm (0,020 – 100) µg/l Kobalt (1,00 – 100) µg/l Magnez (0,050 – 100) mg/l Mangan (1,00 – 10000) µg/l Miedź (1,00 – 1000) µg/l Molibden (1,00 – 100) µg/l Nikiel (1,00 – 1000) µg/l Ołów (0,30 – 100) µg/l Potas (0,050 – 100) mg/l Selen (5,00 – 100) µg/l Sód (0,050 – 100) mg/l Srebro (1,00 – 100) µg/l Tal (0,10 – 100) µg/l Wanad (1,00 – 100) µg/l Wapń (0,10 – 200) mg/l Żelazo (5,00 – 10000) µg/l Tytan (1,00 – 100) µg/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","methodology_en":"Element concentrations Range: Antimony (0,10 – 100) µg/l Arsenic (1,00 – 100) µg/l Barium (1,00 – 1000) µg/l Beryllium (0,10 – 100) µg/l Boron (5,00 – 10000) µg/l Total chromium (1,00 – 100) µg/l Tin (1,00 – 100) µg/l Zinc (1,00 – 1000) µg/l Aluminium (5,00 – 10000) µg/l Cadmium (0,020 – 100) µg/l Cobalt (1,00 – 100) µg/l Magnesium (0,050 – 100) mg/l Manganese (1,00 – 10000) µg/l Copper (1,00 – 1000) µg/l Molybdenum (1,00 – 100) µg/l Nickel (1,00 – 1000) µg/l Lead (0,30 – 100) µg/l Potassium (0,050 – 100) mg/l Selenium (5,00 – 100) µg/l Sodium (0,050 – 100) mg/l Silver (1,00 – 100) µg/l Thallium (0,10 – 100) µg/l Vanadium (1,00 – 100) µg/l Calcium (0,10 – 200) mg/l Iron (5,00 – 10000) µg/l Titanium (1,00 – 100) µg/l Inductively coupled plasma mass spectrometry (ICP-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: Antymon (0,10 – 100) µg/l Arsen (1,00 – 100) µg/l Bar (1,00 – 1000) µg/l Beryl (0,10 – 100) µg/l Bor (5,00 – 10000) µg/l Chrom ogólny (1,00 – 100) µg/l Cyna (1,00 – 100) µg/l Cynk (1,00 – 1000) µg/l Glin (5,00 – 10000) µg/l Kadm (0,020 – 100) µg/l Kobalt (1,00 – 100) µg/l Magnez (0,050 – 100) mg/l Mangan (1,00 – 10000) µg/l Miedź (1,00 – 1000) µg/l Molibden (1,00 – 100) µg/l Nikiel (1,00 – 1000) µg/l Ołów (0,30 – 100) µg/l Potas (0,050 – 100) mg/l Selen (5,00 – 100) µg/l Sód (0,050 – 100) mg/l Srebro (1,00 – 100) µg/l Tal (0,10 – 100) µg/l Wanad (1,00 – 100) µg/l Wapń (0,10 – 200) mg/l Żelazo (5,00 – 10000) µg/l Tytan (1,00 – 100) µg/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie pierwiastków Zakres: Antymon (0,10 – 100) µg/l Arsen (1,00 – 100) µg/l Bar (1,00 – 1000) µg/l Beryl (0,10 – 100) µg/l Bor (5,00 – 10000) µg/l Chrom ogólny (1,00 – 100) µg/l Cyna (1,00 – 100) µg/l Cynk (1,00 – 1000) µg/l Glin (5,00 – 10000) µg/l Kadm (0,020 – 100) µg/l Kobalt (1,00 – 100) µg/l Magnez (0,050 – 100) mg/l Mangan (1,00 – 10000) µg/l Miedź (1,00 – 1000) µg/l Molibden (1,00 – 100) µg/l Nikiel (1,00 – 1000) µg/l Ołów (0,30 – 100) µg/l Potas (0,050 – 100) mg/l Selen (5,00 – 100) µg/l Sód (0,050 – 100) mg/l Srebro (1,00 – 100) µg/l Tal (0,10 – 100) µg/l Wanad (1,00 – 100) µg/l Wapń (0,10 – 200) mg/l Żelazo (5,00 – 10000) µg/l Tytan (1,00 – 100) µg/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda Stezenie pierwiastkow Zakres: Antymon (0,10 – 100) µg/l Arsen (1,00 – 100) µg/l Bar (1,00 – 1000) µg/l Beryl (0,10 – 100) µg/l Bor (5,00 – 10000) µg/l Chrom ogolny (1,00 – 100) µg/l Cyna (1,00 – 100) µg/l Cynk (1,00 – 1000) µg/l Glin (5,00 – 10000) µg/l Kadm (0,020 – 100) µg/l Kobalt (1,00 – 100) µg/l Magnez (0,050 – 100) mg/l Mangan (1,00 – 10000) µg/l Miedz (1,00 – 1000) µg/l Molibden (1,00 – 100) µg/l Nikiel (1,00 – 1000) µg/l Olow (0,30 – 100) µg/l Potas (0,050 – 100) mg/l Selen (5,00 – 100) µg/l Sod (0,050 – 100) mg/l Srebro (1,00 – 100) µg/l Tal (0,10 – 100) µg/l Wanad (1,00 – 100) µg/l Wapn (0,10 – 200) mg/l Zelazo (5,00 – 10000) µg/l Tytan (1,00 – 100) µg/l Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Element concentrations Range: Antimony (0,10 – 100) µg/l Arsenic (1,00 – 100) µg/l Barium (1,00 – 1000) µg/l Beryllium (0,10 – 100) µg/l Boron (5,00 – 10000) µg/l Total chromium (1,00 – 100) µg/l Tin (1,00 – 100) µg/l Zinc (1,00 – 1000) µg/l Aluminium (5,00 – 10000) µg/l Cadmium (0,020 – 100) µg/l Cobalt (1,00 – 100) µg/l Magnesium (0,050 – 100) mg/l Manganese (1,00 – 10000) µg/l Copper (1,00 – 1000) µg/l Molybdenum (1,00 – 100) µg/l Nickel (1,00 – 1000) µg/l Lead (0,30 – 100) µg/l Potassium (0,050 – 100) mg/l Selenium (5,00 – 100) µg/l Sodium (0,050 – 100) mg/l Silver (1,00 – 100) µg/l Thallium (0,10 – 100) µg/l Vanadium (1,00 – 100) µg/l Calcium (0,10 – 200) mg/l Iron (5,00 – 10000) µg/l Titanium (1,00 – 100) µg/l Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04","search_zh":"水 PN-EN ISO 17294-2:2024-04","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253bd1","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych Zakres: Benzo(a)piren (0,00012 – 2,0) µg/l Benzo(b)fluoranten (0,0013 – 2,0) µg/l Benzo(k)fluoranten (0,0013 – 2,0) µg/l Antracen (0,003 – 2,0) µg/l Fluoranten (0,002 – 2,0) µg/l Naftalen (0,002 – 2,0) µg/l Benzo(g,h,i)perylen (0,0012 – 2,0) µg/l Indeno(1,2,3-cd)piren (0,0011 – 2,0) µg/l Dibenzo(a,h)antracen (0,003 – 2,0) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC–FLD) Suma WWA (z obliczeń)","methodology_en":"Concentration of polycyclic aromatic hydrocarbons Range: Benzo(a)pyrene (0,00012 – 2,0) µg/l Benzo(b)fluoranthene (0,0013 – 2,0) µg/l Benzo(k)fluoranthene (0,0013 – 2,0) µg/l Anthracene (0,003 – 2,0) µg/l Fluoranthene (0,002 – 2,0) µg/l Naphthalene (0,002 – 2,0) µg/l Benzo(g,h,i)perylene (0,0012 – 2,0) µg/l Indeno(1,2,3-cd)pyrene (0,0011 – 2,0) µg/l Dibenzo(a,h)anthracene (0,003 – 2,0) µg/l High performance liquid chromatography method with fluorescence detection (HPLC–FLD) Sum of PAH (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych Zakres: Benzo(a)piren (0,00012 – 2,0) µg/l Benzo(b)fluoranten (0,0013 – 2,0) µg/l Benzo(k)fluoranten (0,0013 – 2,0) µg/l Antracen (0,003 – 2,0) µg/l Fluoranten (0,002 – 2,0) µg/l Naftalen (0,002 – 2,0) µg/l Benzo(g,h,i)perylen (0,0012 – 2,0) µg/l Indeno(1,2,3-cd)piren (0,0011 – 2,0) µg/l Dibenzo(a,h)antracen (0,003 – 2,0) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC–FLD) Suma WWA (z obliczeń)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wielopierścieniowych węglowodorów aromatycznych Zakres: Benzo(a)piren (0,00012 – 2,0) µg/l Benzo(b)fluoranten (0,0013 – 2,0) µg/l Benzo(k)fluoranten (0,0013 – 2,0) µg/l Antracen (0,003 – 2,0) µg/l Fluoranten (0,002 – 2,0) µg/l Naftalen (0,002 – 2,0) µg/l Benzo(g,h,i)perylen (0,0012 – 2,0) µg/l Indeno(1,2,3-cd)piren (0,0011 – 2,0) µg/l Dibenzo(a,h)antracen (0,003 – 2,0) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC–FLD) Suma WWA (z obliczeń) PN-EN ISO 17993:2005 Woda Stezenie wielopierscieniowych weglowodorow aromatycznych Zakres: Benzo(a)piren (0,00012 – 2,0) µg/l Benzo(b)fluoranten (0,0013 – 2,0) µg/l Benzo(k)fluoranten (0,0013 – 2,0) µg/l Antracen (0,003 – 2,0) µg/l Fluoranten (0,002 – 2,0) µg/l Naftalen (0,002 – 2,0) µg/l Benzo(g,h,i)perylen (0,0012 – 2,0) µg/l Indeno(1,2,3-cd)piren (0,0011 – 2,0) µg/l Dibenzo(a,h)antracen (0,003 – 2,0) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC–FLD) Suma WWA (z obliczen) PN-EN ISO 17993:2005","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Concentration of polycyclic aromatic hydrocarbons Range: Benzo(a)pyrene (0,00012 – 2,0) µg/l Benzo(b)fluoranthene (0,0013 – 2,0) µg/l Benzo(k)fluoranthene (0,0013 – 2,0) µg/l Anthracene (0,003 – 2,0) µg/l Fluoranthene (0,002 – 2,0) µg/l Naphthalene (0,002 – 2,0) µg/l Benzo(g,h,i)perylene (0,0012 – 2,0) µg/l Indeno(1,2,3-cd)pyrene (0,0011 – 2,0) µg/l Dibenzo(a,h)anthracene (0,003 – 2,0) µg/l High performance liquid chromatography method with fluorescence detection (HPLC–FLD) Sum of PAH (calculated) PN-EN ISO 17993:2005","search_zh":"水 PN-EN ISO 17993:2005","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253bd2","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych Zakres: Benzo(a)piren (0,003 – 2,0) µg/l Benzo(b)fluoranten (0,003 – 2,0) µg/l Benzo(k)fluoranten (0,003 – 2,0) µg/l Benzo(g,h,i)perylen (0,003 – 2,0) µg/l Indeno(1,2,3-cd)piren (0,003 – 2,0) µg/l Dibenzo(a,h)antracen (0,003 – 2,0) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC–FLD) Suma WWA (z obliczeń)","methodology_en":"Concentration of polycyclic aromatic hydrocarbons Range: Benzo(a)pyrene (0,003 – 2,0) µg/l Benzo(b)fluoranthene (0,003 – 2,0) µg/l Benzo(k)fluoranthene (0,003 – 2,0) µg/l Benzo(g,h,i)perylene (0,003 – 2,0) µg/l Indeno(1,2,3-cd)pyrene (0,003 – 2,0) µg/l Dibenzo(a,h)anthracene (0,003 – 2,0) µg/l High performance liquid chromatography method with fluorescence detection (HPLC–FLD) Sum of PAH (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych Zakres: Benzo(a)piren (0,003 – 2,0) µg/l Benzo(b)fluoranten (0,003 – 2,0) µg/l Benzo(k)fluoranten (0,003 – 2,0) µg/l Benzo(g,h,i)perylen (0,003 – 2,0) µg/l Indeno(1,2,3-cd)piren (0,003 – 2,0) µg/l Dibenzo(a,h)antracen (0,003 – 2,0) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC–FLD) Suma WWA (z obliczeń)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych Zakres: Benzo(a)piren (0,003 – 2,0) µg/l Benzo(b)fluoranten (0,003 – 2,0) µg/l Benzo(k)fluoranten (0,003 – 2,0) µg/l Benzo(g,h,i)perylen (0,003 – 2,0) µg/l Indeno(1,2,3-cd)piren (0,003 – 2,0) µg/l Dibenzo(a,h)antracen (0,003 – 2,0) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC–FLD) Suma WWA (z obliczeń) PN-EN ISO 17993:2005 Scieki Stezenie wielopierscieniowych weglowodorow aromatycznych Zakres: Benzo(a)piren (0,003 – 2,0) µg/l Benzo(b)fluoranten (0,003 – 2,0) µg/l Benzo(k)fluoranten (0,003 – 2,0) µg/l Benzo(g,h,i)perylen (0,003 – 2,0) µg/l Indeno(1,2,3-cd)piren (0,003 – 2,0) µg/l Dibenzo(a,h)antracen (0,003 – 2,0) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC–FLD) Suma WWA (z obliczen) PN-EN ISO 17993:2005","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Concentration of polycyclic aromatic hydrocarbons Range: Benzo(a)pyrene (0,003 – 2,0) µg/l Benzo(b)fluoranthene (0,003 – 2,0) µg/l Benzo(k)fluoranthene (0,003 – 2,0) µg/l Benzo(g,h,i)perylene (0,003 – 2,0) µg/l Indeno(1,2,3-cd)pyrene (0,003 – 2,0) µg/l Dibenzo(a,h)anthracene (0,003 – 2,0) µg/l High performance liquid chromatography method with fluorescence detection (HPLC–FLD) Sum of PAH (calculated) PN-EN ISO 17993:2005","search_zh":"污水 PN-EN ISO 17993:2005","test_object_zh":"污水"},{"_id":"6a5a56009af9f73f38253bd3","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci Zakres: (0,000200 – 1,00) mg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","methodology_en":"Mercury concentration Range: (0,000200 – 1,00) mg/l Atomic absorption spectrometry with amalgamation technique","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,000200 – 1,00) mg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"EPA METHOD 7473 02.2007","norm_bases":["EPA METHOD 7473 02.2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci Zakres: (0,000200 – 1,00) mg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji EPA METHOD 7473 02.2007 Scieki Stezenie rteci Zakres: (0,000200 – 1,00) mg/l Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji EPA METHOD 7473 02.2007","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Mercury concentration Range: (0,000200 – 1,00) mg/l Atomic absorption spectrometry with amalgamation technique EPA METHOD 7473 02.2007","search_zh":"污水 EPA METHOD 7473 02.2007","test_object_zh":"污水"},{"_id":"6a5a56009af9f73f38253bd4","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie pierwiastków Zakres: Antymon (0,0100 – 10,0) mg/l Arsen (0,0100 – 10,0) mg/l Bar (0,0100 – 10,0) mg/l Beryl (0,0100 – 10,0) mg/l Bor (0,0500 – 10,0) mg/l Chrom ogólny (0,0100 – 10,0) mg/l Cyna (0,0100 – 10,0) mg/l Cynk (0,0500 – 10,0) mg/l Glin (0,100 – 10,0) mg/l Kadm (0,0010 – 10,0) mg/l Kobalt (0,0100 – 10,0) mg/l Mangan (0,0100 – 10,0) mg/l Miedź (0,0100 – 10,0) mg/l Molibden (0,0100 – 10,0) mg/l Nikiel (0,0100 – 10,0) mg/l Ołów (0,0100 – 10,0) mg/l Selen (0,0500 – 10,0) mg/l Srebro (0,0100 – 10,0) mg/l Tal (0,0100 – 10,0) mg/l Wanad (0,0100 – 10,0) mg/l Żelazo (0,100 – 10,0) mg/l Tytan (0,0100 – 10,0) mg/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","methodology_en":"Element concentrations Range: Antimony (0,0100 – 10,0) mg/l Arsenic (0,0100 – 10,0) mg/l Barium (0,0100 – 10,0) mg/l Beryllium (0,0100 – 10,0) mg/l Boron (0,0500 – 10,0) mg/l Total chromium (0,0100 – 10,0) mg/l Tin (0,0100 – 10,0) mg/l Zinc (0,0500 – 10,0) mg/l Aluminium (0,100 – 10,0) mg/l Cadmium (0,0010 – 10,0) mg/l Cobalt (0,0100 – 10,0) mg/l Manganese (0,0100 – 10,0) mg/l Copper (0,0100 – 10,0) mg/l Molybdenum (0,0100 – 10,0) mg/l Nickel (0,0100 – 10,0) mg/l Lead (0,0100 – 10,0) mg/l Selenium (0,0500 – 10,0) mg/l Silver (0,0100 – 10,0) mg/l Thallium (0,0100 – 10,0) mg/l Vanadium (0,0100 – 10,0) mg/l Iron (0,100 – 10,0) mg/l Titanium (0,0100 – 10,0) mg/l Inductively coupled plasma mass spectrometry (ICP-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: Antymon (0,0100 – 10,0) mg/l Arsen (0,0100 – 10,0) mg/l Bar (0,0100 – 10,0) mg/l Beryl (0,0100 – 10,0) mg/l Bor (0,0500 – 10,0) mg/l Chrom ogólny (0,0100 – 10,0) mg/l Cyna (0,0100 – 10,0) mg/l Cynk (0,0500 – 10,0) mg/l Glin (0,100 – 10,0) mg/l Kadm (0,0010 – 10,0) mg/l Kobalt (0,0100 – 10,0) mg/l Mangan (0,0100 – 10,0) mg/l Miedź (0,0100 – 10,0) mg/l Molibden (0,0100 – 10,0) mg/l Nikiel (0,0100 – 10,0) mg/l Ołów (0,0100 – 10,0) mg/l Selen (0,0500 – 10,0) mg/l Srebro (0,0100 – 10,0) mg/l Tal (0,0100 – 10,0) mg/l Wanad (0,0100 – 10,0) mg/l Żelazo (0,100 – 10,0) mg/l Tytan (0,0100 – 10,0) mg/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie pierwiastków Zakres: Antymon (0,0100 – 10,0) mg/l Arsen (0,0100 – 10,0) mg/l Bar (0,0100 – 10,0) mg/l Beryl (0,0100 – 10,0) mg/l Bor (0,0500 – 10,0) mg/l Chrom ogólny (0,0100 – 10,0) mg/l Cyna (0,0100 – 10,0) mg/l Cynk (0,0500 – 10,0) mg/l Glin (0,100 – 10,0) mg/l Kadm (0,0010 – 10,0) mg/l Kobalt (0,0100 – 10,0) mg/l Mangan (0,0100 – 10,0) mg/l Miedź (0,0100 – 10,0) mg/l Molibden (0,0100 – 10,0) mg/l Nikiel (0,0100 – 10,0) mg/l Ołów (0,0100 – 10,0) mg/l Selen (0,0500 – 10,0) mg/l Srebro (0,0100 – 10,0) mg/l Tal (0,0100 – 10,0) mg/l Wanad (0,0100 – 10,0) mg/l Żelazo (0,100 – 10,0) mg/l Tytan (0,0100 – 10,0) mg/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Scieki Stezenie pierwiastkow Zakres: Antymon (0,0100 – 10,0) mg/l Arsen (0,0100 – 10,0) mg/l Bar (0,0100 – 10,0) mg/l Beryl (0,0100 – 10,0) mg/l Bor (0,0500 – 10,0) mg/l Chrom ogolny (0,0100 – 10,0) mg/l Cyna (0,0100 – 10,0) mg/l Cynk (0,0500 – 10,0) mg/l Glin (0,100 – 10,0) mg/l Kadm (0,0010 – 10,0) mg/l Kobalt (0,0100 – 10,0) mg/l Mangan (0,0100 – 10,0) mg/l Miedz (0,0100 – 10,0) mg/l Molibden (0,0100 – 10,0) mg/l Nikiel (0,0100 – 10,0) mg/l Olow (0,0100 – 10,0) mg/l Selen (0,0500 – 10,0) mg/l Srebro (0,0100 – 10,0) mg/l Tal (0,0100 – 10,0) mg/l Wanad (0,0100 – 10,0) mg/l Zelazo (0,100 – 10,0) mg/l Tytan (0,0100 – 10,0) mg/l Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Element concentrations Range: Antimony (0,0100 – 10,0) mg/l Arsenic (0,0100 – 10,0) mg/l Barium (0,0100 – 10,0) mg/l Beryllium (0,0100 – 10,0) mg/l Boron (0,0500 – 10,0) mg/l Total chromium (0,0100 – 10,0) mg/l Tin (0,0100 – 10,0) mg/l Zinc (0,0500 – 10,0) mg/l Aluminium (0,100 – 10,0) mg/l Cadmium (0,0010 – 10,0) mg/l Cobalt (0,0100 – 10,0) mg/l Manganese (0,0100 – 10,0) mg/l Copper (0,0100 – 10,0) mg/l Molybdenum (0,0100 – 10,0) mg/l Nickel (0,0100 – 10,0) mg/l Lead (0,0100 – 10,0) mg/l Selenium (0,0500 – 10,0) mg/l Silver (0,0100 – 10,0) mg/l Thallium (0,0100 – 10,0) mg/l Vanadium (0,0100 – 10,0) mg/l Iron (0,100 – 10,0) mg/l Titanium (0,0100 – 10,0) mg/l Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04","search_zh":"污水 PN-EN ISO 17294-2:2024-04","test_object_zh":"污水"},{"_id":"6a5a56009af9f73f38253bd5","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO) Zakres: (1,00 – 500) mg/l Metoda spektrometrii w zakresie podczerwieni IR","methodology_en":"Total organic carbon (TOC) concentration Range: (1,00 – 500) mg/l Infrared range spectrometry method IR","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) Zakres: (1,00 – 500) mg/l Metoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie ogólnego węgla organicznego (OWO) Zakres: (1,00 – 500) mg/l Metoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda Scieki Stezenie ogolnego wegla organicznego (OWO) Zakres: (1,00 – 500) mg/l Metoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total organic carbon (TOC) concentration Range: (1,00 – 500) mg/l Infrared range spectrometry method IR PN-EN 1484:1999","search_zh":"水 废水 PN-EN 1484:1999","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bd6","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotynowego − N NO2 Zakres: (0,004 – 2,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Nitrite nitrogen concentration − N NO2 Range: (0,004 – 2,0) mg/l Continuous flow analysis (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego − N NO2 Zakres: (0,004 – 2,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotynowego − N NO2 Zakres: (0,004 – 2,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda Scieki Stezenie azotu azotynowego − N NO2 Zakres: (0,004 – 2,0) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite nitrogen concentration − N NO2 Range: (0,004 – 2,0) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001","search_zh":"水 废水 PN-EN ISO 13395:2001","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bd7","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotynów – NO 2 (z obliczeń)","methodology_en":"Nitrite concentration – NO 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów – NO 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotynów – NO 2 (z obliczeń) Woda Scieki Stezenie azotynow – NO 2 (z obliczen)","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite concentration – NO 2 (calculated)","search_zh":"水 废水","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bd8","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (0,5 – 50,0) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (0,5 – 50,0) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (0,5 – 50,0) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu Kjeldahla Zakres: (0,5 – 50,0) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda Scieki Stezenie azotu Kjeldahla Zakres: (0,5 – 50,0) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Kjeldahl nitrogen concentration Range: (0,5 – 50,0) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水 废水 PN-EN 25663:2001","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bd9","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu ogólnego Suma N , N i N kjeld NO2 NO3 (z obliczeń)","methodology_en":"Total nitrogen concentration Sum of N , N and N kjeld NO2 NO3 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Suma N , N i N kjeld NO2 NO3 (z obliczeń)","reference":"PB-21/LO, wydanie 3 z dnia 01.08.2025 r.","norm_bases":["PB-21/LO, wydanie 3 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu ogólnego Suma N , N i N kjeld NO2 NO3 (z obliczeń) PB-21/LO, wydanie 3 z dnia 01.08.2025 r. Woda Scieki Stezenie azotu ogolnego Suma N , N i N kjeld NO2 NO3 (z obliczen) PB-21/LO, wydanie 3 z dnia 01.08.2025 r.","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total nitrogen concentration Sum of N , N and N kjeld NO2 NO3 (calculated) PB-21/LO, wydanie 3 z dnia 01.08.2025 r.","search_zh":"水 废水 PB-21/LO, wydanie 3 z dnia 01.08.2025 r.","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bda","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforanów Zakres: (0,03 – 20,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Phosphate concentration Range: (0,03 – 20,0) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforanów Zakres: (0,03 – 20,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforanów Zakres: (0,03 – 20,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda Scieki Stezenie fosforanow Zakres: (0,03 – 20,0) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Phosphate concentration Range: (0,03 – 20,0) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02","search_zh":"水 废水 PN-EN ISO 15681-2:2019-02","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bdb","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu fosforanowego – P (z obliczeń)","methodology_en":"Phosphate phosphorus concentration – P (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu fosforanowego – P (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu fosforanowego – P (z obliczeń) Woda Scieki Stezenie fosforu fosforanowego – P (z obliczen)","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Phosphate phosphorus concentration – P (calculated)","search_zh":"水 废水","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bdc","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Zawiesina ogólna Zakres: (2 – 1000) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (2 – 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesina ogólna Zakres: (2 – 1000) mg/l Metoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Zawiesina ogólna Zakres: (2 – 1000) mg/l Metoda wagowa PN-EN 872:2007 + Ap1:2007 Woda Scieki Zawiesina ogolna Zakres: (2 – 1000) mg/l Metoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total suspended solids Range: (2 – 1000) mg/l Gravimetric method PN-EN 872:2007 + Ap1:2007","search_zh":"水 废水 PN-EN 872:2007 + Ap1:2007","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bdd","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie chromu (Cr+6) Zakres: (0,02 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Chromium (Cr+6) concentration Range: (0,02 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu (Cr+6) Zakres: (0,02 – 2,0) mg/l Metoda spektrofotometryczna","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie chromu (Cr+6) Zakres: (0,02 – 2,0) mg/l Metoda spektrofotometryczna PN-77/C-04604/08 Woda Scieki Stezenie chromu (Cr+6) Zakres: (0,02 – 2,0) mg/l Metoda spektrofotometryczna PN-77/C-04604/08","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chromium (Cr+6) concentration Range: (0,02 – 2,0) mg/l Spectrophotometric method PN-77/C-04604/08","search_zh":"水 废水 PN-77/C-04604/08","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bde","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie anionów: Zakres: Chlorki (3,5 – 500) mg/l Siarczany (2,0 – 500) mg/l Azotyny (0,25 – 20,0) mg/l Stężenie azotu azotynowego – NNO2 (z obliczeń) Azotany (1,7 – 100) mg/l Stężenie azotu azotanowego – NNO3 (z obliczeń) Fluorki (0,15 – 10,0) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations: Range: Chlorides (3,5 – 500) mg/l Sulfates (2,0 – 500) mg/l Nitrites (0,25 – 20,0) mg/l Nitrite nitrogen concentration – NNO2 (calculated) Nitrates (1,7 – 100) mg/l Nitrate nitrogen concentration – NNO3 (calculated) Fluorides (0,15 – 10,0) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów: Zakres: Chlorki (3,5 – 500) mg/l Siarczany (2,0 – 500) mg/l Azotyny (0,25 – 20,0) mg/l Stężenie azotu azotynowego – NNO2 (z obliczeń) Azotany (1,7 – 100) mg/l Stężenie azotu azotanowego – NNO3 (z obliczeń) Fluorki (0,15 – 10,0) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie anionów: Zakres: Chlorki (3,5 – 500) mg/l Siarczany (2,0 – 500) mg/l Azotyny (0,25 – 20,0) mg/l Stężenie azotu azotynowego – NNO2 (z obliczeń) Azotany (1,7 – 100) mg/l Stężenie azotu azotanowego – NNO3 (z obliczeń) Fluorki (0,15 – 10,0) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda Scieki Stezenie anionow: Zakres: Chlorki (3,5 – 500) mg/l Siarczany (2,0 – 500) mg/l Azotyny (0,25 – 20,0) mg/l Stezenie azotu azotynowego – NNO2 (z obliczen) Azotany (1,7 – 100) mg/l Stezenie azotu azotanowego – NNO3 (z obliczen) Fluorki (0,15 – 10,0) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Anion concentrations: Range: Chlorides (3,5 – 500) mg/l Sulfates (2,0 – 500) mg/l Nitrites (0,25 – 20,0) mg/l Nitrite nitrogen concentration – NNO2 (calculated) Nitrates (1,7 – 100) mg/l Nitrate nitrogen concentration – NNO3 (calculated) Fluorides (0,15 – 10,0) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","search_zh":"水 废水 PN-EN ISO 10304-1:2009 +AC:2012","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bdf","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,05 – 25,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,05 – 25,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,05 – 25,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu ogólnego Zakres: (0,05 – 25,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Woda Scieki Stezenie fosforu ogolnego Zakres: (0,05 – 25,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total phosphorus concentration Range: (0,05 – 25,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","search_zh":"水 废水 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253be0","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水 废水 五日生化需氧量 BZT 5 范围：(3,0 – 6000) mg/l O 2 电化学法 PN-EN ISO 5815-1:2019-12","test_object_zh":"水 废水","methodology_zh":"五日生化需氧量 BZT 5 范围：(3,0 – 6000) mg/l O 2 电化学法"},{"_id":"6a5a56009af9f73f38253be1","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,50 – 8,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,50 – 8,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,50 – 8,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,50 – 8,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,50 – 8,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (0,50 – 8,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水 废水 PN-EN 1899-2:2002","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253be2","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (10,0 – 1000) mg/l Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand COD-Cr Range: (10,0 – 1000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (10,0 – 1000) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (10,0 – 1000) mg/l Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (10,0 – 1000) mg/l Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand COD-Cr Range: (10,0 – 1000) mg/l Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 废水 PN-ISO 15705:2005","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253be3","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Indeks oleju mineralnego Zakres: (0,06 – 500) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Mineral oil index Range: (0,06 – 500) mg/l Gas chromatography with flame ionisation detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego Zakres: (0,06 – 500) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-ISO 9377-2:2003","norm_bases":["PN-ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Indeks oleju mineralnego Zakres: (0,06 – 500) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-ISO 9377-2:2003 Woda Scieki Indeks oleju mineralnego Zakres: (0,06 – 500) mg/l Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-ISO 9377-2:2003","categories":["water","petro"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Mineral oil index Range: (0,06 – 500) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-ISO 9377-2:2003","search_zh":"水 废水 PN-ISO 9377-2:2003","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253be4","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość rtęci Zakres: (0,0300 – 2,00) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","methodology_en":"Mercury content Range: (0,0300 – 2,00) mg/kg Atomic absorption spectrometry with amalgamation technique","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,0300 – 2,00) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"EPA METHOD 7473 02.2007","norm_bases":["EPA METHOD 7473 02.2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość rtęci Zakres: (0,0300 – 2,00) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji EPA METHOD 7473 02.2007 Gleba Zawartosc rteci Zakres: (0,0300 – 2,00) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji EPA METHOD 7473 02.2007","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Mercury content Range: (0,0300 – 2,00) mg/kg Atomic absorption spectrometry with amalgamation technique EPA METHOD 7473 02.2007","search_zh":"土壤 EPA METHOD 7473 02.2007","test_object_zh":"土壤"},{"_id":"6a5a56009af9f73f38253be5","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość pierwiastków Zakres: Arsen (0,2 – 400) mg/kg Bar (2,0 – 400) mg/kg Chrom ogólny (0,2 – 400) mg/kg Cynk (2,0 – 400) mg/kg Kadm (0,2 – 400) mg/kg Kobalt (0,2 – 400) mg/kg Miedź (2,0 – 400) mg/kg Molibden (0,2 – 400) mg/kg Nikiel (0,2 – 400) mg/kg Ołów (0,2 – 400) mg/kg Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","methodology_en":"Content of elements Range: Arsenic (0,2 – 400) mg/kg Barium (2,0 – 400) mg/kg Total chromium (0,2 – 400) mg/kg Zinc (2,0 – 400) mg/kg Cadmium (0,2 – 400) mg/kg Cobalt (0,2 – 400) mg/kg Copper (2,0 – 400) mg/kg Molybdenum (0,2 – 400) mg/kg Nickel (0,2 – 400) mg/kg Lead (0,2 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: Arsen (0,2 – 400) mg/kg Bar (2,0 – 400) mg/kg Chrom ogólny (0,2 – 400) mg/kg Cynk (2,0 – 400) mg/kg Kadm (0,2 – 400) mg/kg Kobalt (0,2 – 400) mg/kg Miedź (2,0 – 400) mg/kg Molibden (0,2 – 400) mg/kg Nikiel (0,2 – 400) mg/kg Ołów (0,2 – 400) mg/kg Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16173:2012 PN-EN 16171:2017-02","norm_bases":["PN-EN 16173:2012 PN-EN 16171:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość pierwiastków Zakres: Arsen (0,2 – 400) mg/kg Bar (2,0 – 400) mg/kg Chrom ogólny (0,2 – 400) mg/kg Cynk (2,0 – 400) mg/kg Kadm (0,2 – 400) mg/kg Kobalt (0,2 – 400) mg/kg Miedź (2,0 – 400) mg/kg Molibden (0,2 – 400) mg/kg Nikiel (0,2 – 400) mg/kg Ołów (0,2 – 400) mg/kg Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16173:2012 PN-EN 16171:2017-02 Gleba Zawartosc pierwiastkow Zakres: Arsen (0,2 – 400) mg/kg Bar (2,0 – 400) mg/kg Chrom ogolny (0,2 – 400) mg/kg Cynk (2,0 – 400) mg/kg Kadm (0,2 – 400) mg/kg Kobalt (0,2 – 400) mg/kg Miedz (2,0 – 400) mg/kg Molibden (0,2 – 400) mg/kg Nikiel (0,2 – 400) mg/kg Olow (0,2 – 400) mg/kg Metoda spektometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16173:2012 PN-EN 16171:2017-02","categories":["materials","environment"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Content of elements Range: Arsenic (0,2 – 400) mg/kg Barium (2,0 – 400) mg/kg Total chromium (0,2 – 400) mg/kg Zinc (2,0 – 400) mg/kg Cadmium (0,2 – 400) mg/kg Cobalt (0,2 – 400) mg/kg Copper (2,0 – 400) mg/kg Molybdenum (0,2 – 400) mg/kg Nickel (0,2 – 400) mg/kg Lead (0,2 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) method PN-EN 16173:2012 PN-EN 16171:2017-02","search_zh":"土壤 PN-EN 16173:2012 PN-EN 16171:2017-02","test_object_zh":"土壤"},{"_id":"6a5a56009af9f73f38253be6","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość cyny Zakres: (2,0 – 400) mg/kg Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","methodology_en":"Tin content Range: (2,0 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość cyny Zakres: (2,0 – 400) mg/kg Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16174:2012 PN-EN 16171:2017-02","norm_bases":["PN-EN 16174:2012 PN-EN 16171:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość cyny Zakres: (2,0 – 400) mg/kg Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16174:2012 PN-EN 16171:2017-02 Gleba Zawartosc cyny Zakres: (2,0 – 400) mg/kg Metoda spektometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16174:2012 PN-EN 16171:2017-02","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Tin content Range: (2,0 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 16174:2012 PN-EN 16171:2017-02","search_zh":"土壤 PN-EN 16174:2012 PN-EN 16171:2017-02","test_object_zh":"土壤"},{"_id":"6a5a56009af9f73f38253be7","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"Zawartość rtęci Zakres: (0,0300 – 2,00) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","methodology_en":"Mercury content Range: (0,0300 – 2,00) mg/kg Atomic absorption spectrometry with amalgamation technique","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,0300 – 2,00) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"EPA METHOD 7473 02.2007","norm_bases":["EPA METHOD 7473 02.2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 Zawartość rtęci Zakres: (0,0300 – 2,00) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji EPA METHOD 7473 02.2007 Osady sciekowe Odpady O): kod 19 08 05 Zawartosc rteci Zakres: (0,0300 – 2,00) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji EPA METHOD 7473 02.2007","categories":["water","environment"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 Mercury content Range: (0,0300 – 2,00) mg/kg Atomic absorption spectrometry with amalgamation technique EPA METHOD 7473 02.2007","search_zh":"污水污泥 废物 O)：代码 19 08 05 EPA METHOD 7473 02.2007","test_object_zh":"污水污泥 废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253be8","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"Zawartość pierwiastków Zakres: Arsen (0,2 – 400) mg/kg Chrom ogólny (0,2 – 400) mg/kg Cynk (2,0 – 400) mg/kg Kadm (0,2 – 400) mg/kg Miedź (2,0 – 400) mg/kg Nikiel (0,2 – 400) mg/kg Ołów (0,2 – 400) mg/kg Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","methodology_en":"Content of elements Range: Arsenic (0,2 – 400) mg/kg Total chromium (0,2 – 400) mg/kg Zinc (2,0 – 400) mg/kg Cadmium (0,2 – 400) mg/kg Copper (2,0 – 400) mg/kg Nickel (0,2 – 400) mg/kg Lead (0,2 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: Arsen (0,2 – 400) mg/kg Chrom ogólny (0,2 – 400) mg/kg Cynk (2,0 – 400) mg/kg Kadm (0,2 – 400) mg/kg Miedź (2,0 – 400) mg/kg Nikiel (0,2 – 400) mg/kg Ołów (0,2 – 400) mg/kg Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16171:2017-02","norm_bases":["PN-EN 16171:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 Zawartość pierwiastków Zakres: Arsen (0,2 – 400) mg/kg Chrom ogólny (0,2 – 400) mg/kg Cynk (2,0 – 400) mg/kg Kadm (0,2 – 400) mg/kg Miedź (2,0 – 400) mg/kg Nikiel (0,2 – 400) mg/kg Ołów (0,2 – 400) mg/kg Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16171:2017-02 Osady sciekowe Odpady O): kod 19 08 05 Zawartosc pierwiastkow Zakres: Arsen (0,2 – 400) mg/kg Chrom ogolny (0,2 – 400) mg/kg Cynk (2,0 – 400) mg/kg Kadm (0,2 – 400) mg/kg Miedz (2,0 – 400) mg/kg Nikiel (0,2 – 400) mg/kg Olow (0,2 – 400) mg/kg Metoda spektometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16171:2017-02","categories":["water","environment","materials"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 Content of elements Range: Arsenic (0,2 – 400) mg/kg Total chromium (0,2 – 400) mg/kg Zinc (2,0 – 400) mg/kg Cadmium (0,2 – 400) mg/kg Copper (2,0 – 400) mg/kg Nickel (0,2 – 400) mg/kg Lead (0,2 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) method PN-EN 16171:2017-02","search_zh":"污水污泥 废物 O)：代码 19 08 05 PN-EN 16171:2017-02","test_object_zh":"污水污泥 废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253be9","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"Zawartość wapnia Zakres: (0,2 – 200) g/kg (0,02 – 20,0) % Zawartość magnezu Zakres: (0,02 – 20,0) g/kg (0,002 – 2,0) % Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","methodology_en":"Calcium content Range: (0,2 – 200) g/kg (0,02 – 20,0) % Magnesium content Range: (0,02 – 20,0) g/kg (0,002 – 2,0) % Inductively coupled plasma mass spectrometry (ICP-MS) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wapnia Zakres: (0,2 – 200) g/kg (0,02 – 20,0) % Zawartość magnezu Zakres: (0,02 – 20,0) g/kg (0,002 – 2,0) % Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16171:2017-02","norm_bases":["PN-EN 16171:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 Zawartość wapnia Zakres: (0,2 – 200) g/kg (0,02 – 20,0) % Zawartość magnezu Zakres: (0,02 – 20,0) g/kg (0,002 – 2,0) % Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16171:2017-02 Osady sciekowe Odpady O): kod 19 08 05 Zawartosc wapnia Zakres: (0,2 – 200) g/kg (0,02 – 20,0) % Zawartosc magnezu Zakres: (0,02 – 20,0) g/kg (0,002 – 2,0) % Metoda spektometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16171:2017-02","categories":["water","environment"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 Calcium content Range: (0,2 – 200) g/kg (0,02 – 20,0) % Magnesium content Range: (0,02 – 20,0) g/kg (0,002 – 2,0) % Inductively coupled plasma mass spectrometry (ICP-MS) method PN-EN 16171:2017-02","search_zh":"污水污泥 废物 O)：代码 19 08 05 PN-EN 16171:2017-02","test_object_zh":"污水污泥 废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253bea","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 200) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3,0 – 200) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 200) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 200) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 200) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Biochemical oxygen demand - BOD 5 Range: (3,0 – 200) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253beb","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Indeks nadmanganianowy Zakres: (0,5 – 100) mg/l O 2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (0,5 – 100) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,5 – 100) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Indeks nadmanganianowy Zakres: (0,5 – 100) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy Zakres: (0,5 – 100) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Permanganate index Range: (0,5 – 100) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"水 PN-EN ISO 8467:2001","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253bec","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (5 – 70) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012 metoda D","norm_bases":["PN-EN ISO 7887:2012 metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 metoda D Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 metoda D","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Colour Range: (5 – 70) mg/l Pt Visual method PN-EN ISO 7887:2012 metoda D","methodology_zh":"色度 范围：(5 – 70) mg/l Pt 目视法","search_zh":"水 色度 范围：(5 – 70) mg/l Pt 目视法 PN-EN ISO 7887:2012 metoda D","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253bed","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie fosforu ogólnego Zakres: (0,02 – 4,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,02 – 4,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,02 – 4,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie fosforu ogólnego Zakres: (0,02 – 4,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010 Woda Stezenie fosforu ogolnego Zakres: (0,02 – 4,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total phosphorus concentration Range: (0,02 – 4,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","search_zh":"水 PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253bee","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"污水 五日生化需氧量 BZT 5 范围：(3,0 – 6000) mg/l O 2 电化学法 PN-EN ISO 5815-1:2019-12","test_object_zh":"污水","methodology_zh":"五日生化需氧量 BZT 5 范围：(3,0 – 6000) mg/l O 2 电化学法"},{"_id":"6a5a56009af9f73f38253bef","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,02 – 400) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,02 – 400) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,02 – 400) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego Zakres: (0,02 – 400) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Scieki Stezenie fosforu ogolnego Zakres: (0,02 – 400) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total phosphorus concentration Range: (0,02 – 400) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","search_zh":"污水 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","test_object_zh":"污水"},{"_id":"6a5a56009af9f73f38253bf0","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水 废水 五日生化需氧量 BZT 5 范围：(0,5 – 6,0) mg/l O 2 电化学法 PN-EN 1899-2:2002","test_object_zh":"水 废水","methodology_zh":"五日生化需氧量 BZT 5 范围：(0,5 – 6,0) mg/l O 2 电化学法"},{"_id":"6a5a56009af9f73f38253bf1","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-28/LO, wydanie 3 z dnia 01.08.2025 r.","norm_bases":["PB-28/LO, wydanie 3 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu ogólnego (z obliczeń) PB-28/LO, wydanie 3 z dnia 01.08.2025 r. Woda Scieki Stezenie azotu ogolnego (z obliczen) PB-28/LO, wydanie 3 z dnia 01.08.2025 r.","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total nitrogen concentration (calculated) PB-28/LO, wydanie 3 z dnia 01.08.2025 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水 废水 总氮浓度（计算值） PB-28/LO, wydanie 3 z dnia 01.08.2025 r.","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bf2","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym Zakres: (1,0 – 2500) mg/l Metoda wagowa","methodology_en":"Concentration of substances extractable with petroleum ether Range: (1,0 – 2500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym Zakres: (1,0 – 2500) mg/l Metoda wagowa","reference":"PB-27/LO, wydanie 3 z dnia 01.08.2025 r.","norm_bases":["PB-27/LO, wydanie 3 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie substancji ekstrahujących się eterem naftowym Zakres: (1,0 – 2500) mg/l Metoda wagowa PB-27/LO, wydanie 3 z dnia 01.08.2025 r. Woda Scieki Stezenie substancji ekstrahujacych sie eterem naftowym Zakres: (1,0 – 2500) mg/l Metoda wagowa PB-27/LO, wydanie 3 z dnia 01.08.2025 r.","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Concentration of substances extractable with petroleum ether Range: (1,0 – 2500) mg/l Gravimetric method PB-27/LO, wydanie 3 z dnia 01.08.2025 r.","search_zh":"水 废水 PB-27/LO, wydanie 3 z dnia 01.08.2025 r.","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bf3","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Zawiesiny ogólne Zakres: (2 – 2000) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (2 – 2000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2 – 2000) mg/l Metoda wagowa","reference":"PN-EN 872:2007 +Ap1:2007","norm_bases":["PN-EN 872:2007 +Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Zawiesiny ogólne Zakres: (2 – 2000) mg/l Metoda wagowa PN-EN 872:2007 +Ap1:2007 Woda Scieki Zawiesiny ogolne Zakres: (2 – 2000) mg/l Metoda wagowa PN-EN 872:2007 +Ap1:2007","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total suspended solids Range: (2 – 2000) mg/l Gravimetric method PN-EN 872:2007 +Ap1:2007","search_zh":"水 废水 PN-EN 872:2007 +Ap1:2007","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bf4","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforanów Zakres: (0,05 – 12) mg/l Metoda spektrofotometryczna","methodology_en":"Phosphate concentration Range: (0,05 – 12) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforanów Zakres: (0,05 – 12) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforanów Zakres: (0,05 – 12) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 Woda Scieki Stezenie fosforanow Zakres: (0,05 – 12) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Phosphate concentration Range: (0,05 – 12) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","search_zh":"水 废水 PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bf5","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforanów Zakres: (0,06 – 10) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Phosphate concentration Range: (0,06 – 10) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforanów Zakres: (0,06 – 10) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforanów Zakres: (0,06 – 10) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda Scieki Stezenie fosforanow Zakres: (0,06 – 10) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Phosphate concentration Range: (0,06 – 10) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02","search_zh":"水 废水 PN-EN ISO 15681-2:2019-02","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bf6","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,30 – 50) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Nitrate nitrogen concentration Range: (0,30 – 50) mg/l Continuous flow analysis (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,30 – 50) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotanowego Zakres: (0,30 – 50) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda Scieki Stezenie azotu azotanowego Zakres: (0,30 – 50) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrate nitrogen concentration Range: (0,30 – 50) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001","search_zh":"水 废水 PN-EN ISO 13395:2001","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bf7","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotanów – NO 3 (z obliczeń)","methodology_en":"Nitrate concentration – NO 3 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów – NO 3 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotanów – NO 3 (z obliczeń) Woda Scieki Stezenie azotanow – NO 3 (z obliczen)","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrate concentration – NO 3 (calculated)","search_zh":"水 废水","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bf8","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,10 – 10) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Ammonium nitrogen concentration Range: (0,10 – 10) mg/l Continuous flow analysis (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,10 – 10) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu amonowego Zakres: (0,10 – 10) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Woda Scieki Stezenie azotu amonowego Zakres: (0,10 – 10) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ammonium nitrogen concentration Range: (0,10 – 10) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11732:2007","search_zh":"水 废水 PN-EN ISO 11732:2007","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bf9","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie jonu amonowego, amoniaku (z obliczeń)","methodology_en":"Concentration of ammonium ion, ammonia (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego, amoniaku (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie jonu amonowego, amoniaku (z obliczeń) Woda Scieki Stezenie jonu amonowego, amoniaku (z obliczen)","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Concentration of ammonium ion, ammonia (calculated)","search_zh":"水 废水 铵离子、氨浓度（由计算得出）","test_object_zh":"水 废水","methodology_zh":"铵离子、氨浓度（由计算得出）"},{"_id":"6a5a56009af9f73f38253bfa","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,007 – 1,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Nitrite nitrogen concentration Range: (0,007 – 1,0) mg/l Continuous flow analysis (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,007 – 1,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotynowego Zakres: (0,007 – 1,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda Scieki Stezenie azotu azotynowego Zakres: (0,007 – 1,0) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite nitrogen concentration Range: (0,007 – 1,0) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001","search_zh":"水 废水 PN-EN ISO 13395:2001","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bfb","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie amoniaku niejonowego (z obliczeń)","methodology_en":"Un-ionised ammonia concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie amoniaku niejonowego (z obliczeń)","reference":"PB-29/LO, wydanie 3 z dnia 01.08.2025 r.","norm_bases":["PB-29/LO, wydanie 3 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie amoniaku niejonowego (z obliczeń) PB-29/LO, wydanie 3 z dnia 01.08.2025 r. Woda Scieki Stezenie amoniaku niejonowego (z obliczen) PB-29/LO, wydanie 3 z dnia 01.08.2025 r.","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Un-ionised ammonia concentration (calculated) PB-29/LO, wydanie 3 z dnia 01.08.2025 r.","search_zh":"水 废水 非离子氨浓度（由计算得出） PB-29/LO, wydanie 3 z dnia 01.08.2025 r.","test_object_zh":"水 废水","methodology_zh":"非离子氨浓度（由计算得出）"},{"_id":"6a5a56009af9f73f38253bfc","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,040 – 100) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,040 – 100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,040 – 100) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu amonowego Zakres: (0,040 – 100) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Scieki Stezenie azotu amonowego Zakres: (0,040 – 100) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ammonium nitrogen concentration Range: (0,040 – 100) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 废水 PN-ISO 7150-1:2002","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bfd","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (0,5 – 250) mg/l Metoda spektrofotometryczna","methodology_en":"Kjeldahl nitrogen concentration Range: (0,5 – 250) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (0,5 – 250) mg/l Metoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu Kjeldahla Zakres: (0,5 – 250) mg/l Metoda spektrofotometryczna PN-EN 25663:2001 Woda Scieki Stezenie azotu Kjeldahla Zakres: (0,5 – 250) mg/l Metoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Kjeldahl nitrogen concentration Range: (0,5 – 250) mg/l Spectrophotometric method PN-EN 25663:2001","search_zh":"水 废水 PN-EN 25663:2001","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bfe","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - CHZT-Cr Zakres: (30,0 – 6000) mg/l O 2 Metoda miareczkowa","methodology_en":"Chemical oxygen demand - COD-Cr Range: (30,0 – 6000) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - CHZT-Cr Zakres: (30,0 – 6000) mg/l O 2 Metoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu - CHZT-Cr Zakres: (30,0 – 6000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006 Woda Scieki Chemiczne zapotrzebowanie tlenu - CHZT-Cr Zakres: (30,0 – 6000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand - COD-Cr Range: (30,0 – 6000) mg/l O 2 Titrimetric method PN-ISO 6060:2006","search_zh":"水 废水 PN-ISO 6060:2006","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253bff","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - CHZT-Cr Zakres: (9,0 – 150) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (9,0 – 150) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - CHZT-Cr Zakres: (9,0 – 150) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu - CHZT-Cr Zakres: (9,0 – 150) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Scieki Chemiczne zapotrzebowanie tlenu - CHZT-Cr Zakres: (9,0 – 150) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand - COD-Cr Range: (9,0 – 150) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 废水 PN-ISO 15705:2005","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c00","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fenoli (indeks fenolowy) Zakres: (0,0015 – 5,00) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Phenol concentration (phenol index) Range: (0,0015 – 5,00) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fenoli (indeks fenolowy) Zakres: (0,0015 – 5,00) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004","norm_bases":["PN-EN ISO 14402:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fenoli (indeks fenolowy) Zakres: (0,0015 – 5,00) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 Woda Scieki Stezenie fenoli (indeks fenolowy) Zakres: (0,0015 – 5,00) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Phenol concentration (phenol index) Range: (0,0015 – 5,00) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 14402:2004","search_zh":"水 废水 PN-EN ISO 14402:2004","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c01","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba, odpady O): kod 19 08 05","test_object_en":"Soil, waste O): code 19 08 05","methodology":"Zawartość azotu Kjeldahla Zakres: (0,12 – 64) g/kg Metoda spektrofotometryczna","methodology_en":"Kjeldahl nitrogen content Range: (0,12 – 64) g/kg Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla Zakres: (0,12 – 64) g/kg Metoda spektrofotometryczna","reference":"PB-35/LO, wydanie 3 z dnia 01.08.2025 r.","norm_bases":["PB-35/LO, wydanie 3 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, odpady O): kod 19 08 05 Zawartość azotu Kjeldahla Zakres: (0,12 – 64) g/kg Metoda spektrofotometryczna PB-35/LO, wydanie 3 z dnia 01.08.2025 r. Gleba, odpady O): kod 19 08 05 Zawartosc azotu Kjeldahla Zakres: (0,12 – 64) g/kg Metoda spektrofotometryczna PB-35/LO, wydanie 3 z dnia 01.08.2025 r.","categories":["environment"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, waste O): code 19 08 05 Kjeldahl nitrogen content Range: (0,12 – 64) g/kg Spectrophotometric method PB-35/LO, wydanie 3 z dnia 01.08.2025 r."},{"_id":"6a5a56009af9f73f38253c02","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość substancji organicznych, substancji mineralnych Zakres: (100 – 850) g/kg (10 – 85) % Metoda wagowa","methodology_en":"Content of organic substances, mineral substances Range: (100 – 850) g/kg (10 – 85) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość substancji organicznych, substancji mineralnych Zakres: (100 – 850) g/kg (10 – 85) % Metoda wagowa","reference":"PB-34/LO, wydanie 3 z dnia 01.08.2025 r.","norm_bases":["PB-34/LO, wydanie 3 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość substancji organicznych, substancji mineralnych Zakres: (100 – 850) g/kg (10 – 85) % Metoda wagowa PB-34/LO, wydanie 3 z dnia 01.08.2025 r. Gleba Zawartosc substancji organicznych, substancji mineralnych Zakres: (100 – 850) g/kg (10 – 85) % Metoda wagowa PB-34/LO, wydanie 3 z dnia 01.08.2025 r.","categories":["environment"],"row_index":54,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Content of organic substances, mineral substances Range: (100 – 850) g/kg (10 – 85) % Gravimetric method PB-34/LO, wydanie 3 z dnia 01.08.2025 r.","search_zh":"土壤 PB-34/LO, wydanie 3 z dnia 01.08.2025 r.","test_object_zh":"土壤"},{"_id":"6a5a56009af9f73f38253c03","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość suchej masy / zawartość wody Zakres: (10 – 95) % Metoda wagowa","methodology_en":"Dry matter content / water content Range: (10 – 95) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość suchej masy / zawartość wody Zakres: (10 – 95) % Metoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość suchej masy / zawartość wody Zakres: (10 – 95) % Metoda wagowa PN-ISO 11465:1999 Gleba Zawartosc suchej masy / zawartosc wody Zakres: (10 – 95) % Metoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":55,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Dry matter content / water content Range: (10 – 95) % Gravimetric method PN-ISO 11465:1999","search_zh":"土壤 PN-ISO 11465:1999","test_object_zh":"土壤"},{"_id":"6a5a56009af9f73f38253c04","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH – w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH – in KCl, pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH – w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH – w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH – w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":56,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil pH – in KCl, pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09","search_zh":"土壤 PN-EN ISO 10390:2022-09","test_object_zh":"土壤"},{"_id":"6a5a56009af9f73f38253c05","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe, odpady O): kod 19 08 05","test_object_en":"Sewage sludge, waste O): code 19 08 05","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, odpady O): kod 19 08 05 pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe, odpady O): kod 19 08 05 pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment"],"row_index":57,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, waste O): code 19 08 05 pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09","methodology_zh":"pH 范围：2,0 – 12,0 电位法","search_zh":"污水污泥、废物 O)：代码 19 08 05 pH 范围：2,0 – 12,0 电位法 PN-EN ISO 10390:2022-09","test_object_zh":"污水污泥、废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c06","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe, odpady O): kod 19 08 05","test_object_en":"Sewage sludge, waste O): code 19 08 05","methodology":"Zawartość azotu Kjeldahla Zakres: (3,0 – 64) g/kg (0,3 – 6,4) % Metoda spektrofotometryczna","methodology_en":"Kjeldahl nitrogen content Range: (3,0 – 64) g/kg (0,3 – 6,4) % Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla Zakres: (3,0 – 64) g/kg (0,3 – 6,4) % Metoda spektrofotometryczna","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, odpady O): kod 19 08 05 Zawartość azotu Kjeldahla Zakres: (3,0 – 64) g/kg (0,3 – 6,4) % Metoda spektrofotometryczna PN-EN 13342:2002 Osady sciekowe, odpady O): kod 19 08 05 Zawartosc azotu Kjeldahla Zakres: (3,0 – 64) g/kg (0,3 – 6,4) % Metoda spektrofotometryczna PN-EN 13342:2002","categories":["water","environment"],"row_index":58,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, waste O): code 19 08 05 Kjeldahl nitrogen content Range: (3,0 – 64) g/kg (0,3 – 6,4) % Spectrophotometric method PN-EN 13342:2002","search_zh":"污水污泥、废物 O)：代码 19 08 05 PN-EN 13342:2002","test_object_zh":"污水污泥、废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c07","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe, odpady O): kod 19 08 05","test_object_en":"Sewage sludge, waste O): code 19 08 05","methodology":"Zawartość suchej masy / zawartość wody Zakres:(10 – 90) % (100 – 900) g/kg Metoda wagowa","methodology_en":"Dry matter content / water content Range:(10 – 90) % (100 – 900) g/kg Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość suchej masy / zawartość wody Zakres:(10 – 90) % (100 – 900) g/kg Metoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, odpady O): kod 19 08 05 Zawartość suchej masy / zawartość wody Zakres:(10 – 90) % (100 – 900) g/kg Metoda wagowa PN-EN 12880:2004 Osady sciekowe, odpady O): kod 19 08 05 Zawartosc suchej masy / zawartosc wody Zakres:(10 – 90) % (100 – 900) g/kg Metoda wagowa PN-EN 12880:2004","categories":["water","environment"],"row_index":59,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, waste O): code 19 08 05 Dry matter content / water content Range:(10 – 90) % (100 – 900) g/kg Gravimetric method PN-EN 12880:2004","search_zh":"污水污泥、废物 O)：代码 19 08 05 PN-EN 12880:2004","test_object_zh":"污水污泥、废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c08","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe, odpady O): kod 19 08 05","test_object_en":"Sewage sludge, waste O): code 19 08 05","methodology":"Zawartość fosforu ogólnego Zakres: (1,0 – 20,0) g/kg (0,1 – 2,0) % Metoda spektrofotometryczna","methodology_en":"Total phosphorus content Range: (1,0 – 20,0) g/kg (0,1 – 2,0) % Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego Zakres: (1,0 – 20,0) g/kg (0,1 – 2,0) % Metoda spektrofotometryczna","reference":"PN-EN 14672:2006 PN-EN ISO 6878:2006","norm_bases":["PN-EN 14672:2006 PN-EN ISO 6878:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, odpady O): kod 19 08 05 Zawartość fosforu ogólnego Zakres: (1,0 – 20,0) g/kg (0,1 – 2,0) % Metoda spektrofotometryczna PN-EN 14672:2006 PN-EN ISO 6878:2006 Osady sciekowe, odpady O): kod 19 08 05 Zawartosc fosforu ogolnego Zakres: (1,0 – 20,0) g/kg (0,1 – 2,0) % Metoda spektrofotometryczna PN-EN 14672:2006 PN-EN ISO 6878:2006","categories":["water","environment"],"row_index":60,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, waste O): code 19 08 05 Total phosphorus content Range: (1,0 – 20,0) g/kg (0,1 – 2,0) % Spectrophotometric method PN-EN 14672:2006 PN-EN ISO 6878:2006","search_zh":"污水污泥、废物 O)：代码 19 08 05 PN-EN 14672:2006 PN-EN ISO 6878:2006","test_object_zh":"污水污泥、废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c09","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe, odpady O): kod 19 08 05","test_object_en":"Sewage sludge, waste O): code 19 08 05","methodology":"Strata przy prażeniu (zawartość substancji organicznych) Zakres: (5,0 – 90,0)% Metoda wagowa","methodology_en":"Loss on ignition (organic matter content) Range: (5,0 – 90,0)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strata przy prażeniu (zawartość substancji organicznych) Zakres: (5,0 – 90,0)% Metoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, odpady O): kod 19 08 05 Strata przy prażeniu (zawartość substancji organicznych) Zakres: (5,0 – 90,0)% Metoda wagowa PN-EN 15935:2022-01 Osady sciekowe, odpady O): kod 19 08 05 Strata przy prazeniu (zawartosc substancji organicznych) Zakres: (5,0 – 90,0)% Metoda wagowa PN-EN 15935:2022-01","categories":["water","environment"],"row_index":61,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, waste O): code 19 08 05 Loss on ignition (organic matter content) Range: (5,0 – 90,0)% Gravimetric method PN-EN 15935:2022-01","search_zh":"污水污泥、废物 O)：代码 19 08 05 PN-EN 15935:2022-01","test_object_zh":"污水污泥、废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c0a","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe, odpady O): kod 19 08 05","test_object_en":"Sewage sludge, waste O): code 19 08 05","methodology":"Zawartość azotu amonowego Zakres: (0,40 – 20,0) g/kg (0,04 – 2,00) % Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen content Range: (0,40 – 20,0) g/kg (0,04 – 2,00) % Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego Zakres: (0,40 – 20,0) g/kg (0,04 – 2,00) % Metoda spektrofotometryczna","reference":"PB-42/LO, wydanie 2 z dnia 01.08.2025 r.","norm_bases":["PB-42/LO, wydanie 2 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, odpady O): kod 19 08 05 Zawartość azotu amonowego Zakres: (0,40 – 20,0) g/kg (0,04 – 2,00) % Metoda spektrofotometryczna PB-42/LO, wydanie 2 z dnia 01.08.2025 r. Osady sciekowe, odpady O): kod 19 08 05 Zawartosc azotu amonowego Zakres: (0,40 – 20,0) g/kg (0,04 – 2,00) % Metoda spektrofotometryczna PB-42/LO, wydanie 2 z dnia 01.08.2025 r.","categories":["water","environment"],"row_index":62,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, waste O): code 19 08 05 Ammonium nitrogen content Range: (0,40 – 20,0) g/kg (0,04 – 2,00) % Spectrophotometric method PB-42/LO, wydanie 2 z dnia 01.08.2025 r.","search_zh":"污水污泥、废物 O)：代码 19 08 05 PB-42/LO, wydanie 2 z dnia 01.08.2025 r.","test_object_zh":"污水污泥、废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c0b","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa Zakres: (5 – 70) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (5 – 70) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 70) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C","norm_bases":["PN-EN ISO 7887:2012 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Colour Range: (5 – 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 Metoda C","search_zh":"水 色度 范围：(5 – 70) mg/l Pt 分光光度法 PN-EN ISO 7887:2012 Metoda C","test_object_zh":"水","methodology_zh":"色度 范围：(5 – 70) mg/l Pt 分光光度法"},{"_id":"6a5a56009af9f73f38253c0c","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,030 – 100) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,030 – 100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,030 – 100) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu amonowego Zakres: (0,030 – 100) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Scieki Stezenie azotu amonowego Zakres: (0,030 – 100) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ammonium nitrogen concentration Range: (0,030 – 100) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 废水 PN-ISO 7150-1:2002","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c0d","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,001 – 5) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,001 – 5) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,001 – 5) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotynowego Zakres: (0,001 – 5) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Scieki Stezenie azotu azotynowego Zakres: (0,001 – 5) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite nitrogen concentration Range: (0,001 – 5) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 废水 PN-EN 26777:1999","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c0e","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1 – 150) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1 – 150) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1 – 150) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu Kjeldahla Zakres: (1 – 150) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda Scieki Stezenie azotu Kjeldahla Zakres: (1 – 150) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Kjeldahl nitrogen concentration Range: (1 – 150) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水 废水 PN-EN 25663:2001","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c0f","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-08/LO, wydanie 3 z dnia 01.08.2025 r.","norm_bases":["PB-08/LO, wydanie 3 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu ogólnego (z obliczeń) PB-08/LO, wydanie 3 z dnia 01.08.2025 r. Woda Scieki Stezenie azotu ogolnego (z obliczen) PB-08/LO, wydanie 3 z dnia 01.08.2025 r.","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total nitrogen concentration (calculated) PB-08/LO, wydanie 3 z dnia 01.08.2025 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水 废水 总氮浓度（计算值） PB-08/LO, wydanie 3 z dnia 01.08.2025 r.","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c10","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,005 – 50) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,005 – 50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,005 – 50) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7","norm_bases":["PN-EN ISO 6878:2006 pkt 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu ogólnego Zakres: (0,005 – 50) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 Woda Scieki Stezenie fosforu ogolnego Zakres: (0,005 – 50) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total phosphorus concentration Range: (0,005 – 50) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt 7","search_zh":"水 废水 PN-EN ISO 6878:2006 pkt 7","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c11","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie ortofosforanów rozpuszczonych Zakres: (0,005 – 50,0) mg/l P Metoda spektrofotometryczna","methodology_en":"Dissolved orthophosphate concentration Range: (0,005 – 50,0) mg/l P Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów rozpuszczonych Zakres: (0,005 – 50,0) mg/l P Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 4 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 4 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie ortofosforanów rozpuszczonych Zakres: (0,005 – 50,0) mg/l P Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap2:2010 Woda Scieki Stezenie ortofosforanow rozpuszczonych Zakres: (0,005 – 50,0) mg/l P Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap2:2010","categories":["water"],"row_index":69,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Dissolved orthophosphate concentration Range: (0,005 – 50,0) mg/l P Spectrophotometric method PN-EN ISO 6878:2006 pkt. 4 +Ap2:2010","search_zh":"水 废水 PN-EN ISO 6878:2006 pkt. 4 +Ap2:2010","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c12","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Zawiesiny ogólne Zakres: 2 mg/l – 3 g/l Metoda wagowa","methodology_en":"Total suspended solids Range: 2 mg/l – 3 g/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: 2 mg/l – 3 g/l Metoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Zawiesiny ogólne Zakres: 2 mg/l – 3 g/l Metoda wagowa PN-EN 872:2007 + Ap1:2007 Woda Scieki Zawiesiny ogolne Zakres: 2 mg/l – 3 g/l Metoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total suspended solids Range: 2 mg/l – 3 g/l Gravimetric method PN-EN 872:2007 + Ap1:2007","search_zh":"水 废水 PN-EN 872:2007 + Ap1:2007","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c13","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Surfaktanty anionowe (indeks MBAS) Zakres: (0,06 – 5) mg/l Metoda spektrofotometryczna","methodology_en":"Anionic surfactants (MBAS index) Range: (0,06 – 5) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Surfaktanty anionowe (indeks MBAS) Zakres: (0,06 – 5) mg/l Metoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Surfaktanty anionowe (indeks MBAS) Zakres: (0,06 – 5) mg/l Metoda spektrofotometryczna PN-EN 903:2002 Woda Scieki Surfaktanty anionowe (indeks MBAS) Zakres: (0,06 – 5) mg/l Metoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Anionic surfactants (MBAS index) Range: (0,06 – 5) mg/l Spectrophotometric method PN-EN 903:2002","search_zh":"水 废水 PN-EN 903:2002","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c14","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: 7,5 mg/l O - 5 g/l O 2 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand COD-Cr Range: 7,5 mg/l O - 5 g/l O 2 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: 7,5 mg/l O - 5 g/l O 2 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: 7,5 mg/l O - 5 g/l O 2 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: 7,5 mg/l O - 5 g/l O 2 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand COD-Cr Range: 7,5 mg/l O - 5 g/l O 2 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 废水 PN-ISO 15705:2005","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c15","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Sucha masa Zakres: (60,0 – 99,9)% Zawartość wody Zakres: (0,1 – 40,0)% Metoda wagowa","methodology_en":"Dry matter Range: (60,0 – 99,9)% Water content Range: (0,1 – 40,0)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha masa Zakres: (60,0 – 99,9)% Zawartość wody Zakres: (0,1 – 40,0)% Metoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Sucha masa Zakres: (60,0 – 99,9)% Zawartość wody Zakres: (0,1 – 40,0)% Metoda wagowa PN-ISO 11465:1999 Gleba Sucha masa Zakres: (60,0 – 99,9)% Zawartosc wody Zakres: (0,1 – 40,0)% Metoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":73,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Dry matter Range: (60,0 – 99,9)% Water content Range: (0,1 – 40,0)% Gravimetric method PN-ISO 11465:1999","search_zh":"土壤 PN-ISO 11465:1999","test_object_zh":"土壤"},{"_id":"6a5a56009af9f73f38253c16","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH - w KCl Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH - in KCl Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH - w KCl Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH - w KCl Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w KCl Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":74,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil pH - in KCl Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09","search_zh":"土壤 PN-EN ISO 10390:2022-09","test_object_zh":"土壤"},{"_id":"6a5a56009af9f73f38253c17","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"Zawartość fosforu ogólnego Zakres: (0,1 – 2,5) % (1,0 – 25) g/kg Metoda spektrofotometryczna","methodology_en":"Total phosphorus content Range: (0,1 – 2,5) % (1,0 – 25) g/kg Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego Zakres: (0,1 – 2,5) % (1,0 – 25) g/kg Metoda spektrofotometryczna","reference":"PN-EN14672:2006 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN14672:2006 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 Zawartość fosforu ogólnego Zakres: (0,1 – 2,5) % (1,0 – 25) g/kg Metoda spektrofotometryczna PN-EN14672:2006 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 Osady sciekowe Odpady O): kod 19 08 05 Zawartosc fosforu ogolnego Zakres: (0,1 – 2,5) % (1,0 – 25) g/kg Metoda spektrofotometryczna PN-EN14672:2006 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","categories":["water","environment"],"row_index":75,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 Total phosphorus content Range: (0,1 – 2,5) % (1,0 – 25) g/kg Spectrophotometric method PN-EN14672:2006 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","search_zh":"污水污泥 废物 O)：代码 19 08 05 PN-EN14672:2006 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","test_object_zh":"污水污泥 废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c18","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"Zawartość azotu amonowego Zakres: (0,050 – 1,5) % Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen content Range: (0,050 – 1,5) % Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego Zakres: (0,050 – 1,5) % Metoda spektrofotometryczna","reference":"PB-14/LO, wydanie 4 z dnia 01.08.2025 r.","norm_bases":["PB-14/LO, wydanie 4 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 Zawartość azotu amonowego Zakres: (0,050 – 1,5) % Metoda spektrofotometryczna PB-14/LO, wydanie 4 z dnia 01.08.2025 r. Osady sciekowe Odpady O): kod 19 08 05 Zawartosc azotu amonowego Zakres: (0,050 – 1,5) % Metoda spektrofotometryczna PB-14/LO, wydanie 4 z dnia 01.08.2025 r.","categories":["water","environment"],"row_index":76,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 Ammonium nitrogen content Range: (0,050 – 1,5) % Spectrophotometric method PB-14/LO, wydanie 4 z dnia 01.08.2025 r.","search_zh":"污水污泥 废物 O)：代码 19 08 05 PB-14/LO, wydanie 4 z dnia 01.08.2025 r.","test_object_zh":"污水污泥 废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c19","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"Zawartość azotu Kjeldahla Zakres: (0,01 – 5)% Metoda spektrofotometryczna","methodology_en":"Kjeldahl nitrogen content Range: (0,01 – 5)% Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla Zakres: (0,01 – 5)% Metoda spektrofotometryczna","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 Zawartość azotu Kjeldahla Zakres: (0,01 – 5)% Metoda spektrofotometryczna PN-EN 13342:2002 Osady sciekowe Odpady O): kod 19 08 05 Zawartosc azotu Kjeldahla Zakres: (0,01 – 5)% Metoda spektrofotometryczna PN-EN 13342:2002","categories":["water","environment"],"row_index":77,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 Kjeldahl nitrogen content Range: (0,01 – 5)% Spectrophotometric method PN-EN 13342:2002","search_zh":"污水污泥 废物 O)：代码 19 08 05 PN-EN 13342:2002","test_object_zh":"污水污泥 废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c1a","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe Odpady O): kod 19 08 05 pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment"],"row_index":78,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09","search_zh":"污水污泥 废物 O)：代码 19 08 05 pH － 于 H2O 中 范围：2,0 – 12,0 电位法 PN-EN ISO 10390:2022-09","test_object_zh":"污水污泥 废物 O)：代码 19 08 05","methodology_zh":"pH － 于 H2O 中 范围：2,0 – 12,0 电位法"},{"_id":"6a5a56009af9f73f38253c1b","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"Sucha pozostałość, zawartość wody Zakres: (5 – 95)% Metoda wagowa","methodology_en":"Dry residue, water content Range: (5 – 95)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha pozostałość, zawartość wody Zakres: (5 – 95)% Metoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 Sucha pozostałość, zawartość wody Zakres: (5 – 95)% Metoda wagowa PN-EN 12880:2004 Osady sciekowe Odpady O): kod 19 08 05 Sucha pozostalosc, zawartosc wody Zakres: (5 – 95)% Metoda wagowa PN-EN 12880:2004","categories":["water","environment"],"row_index":79,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 Dry residue, water content Range: (5 – 95)% Gravimetric method PN-EN 12880:2004","search_zh":"污水污泥 废物 O)：代码 19 08 05 PN-EN 12880:2004","test_object_zh":"污水污泥 废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c1c","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"Strata przy prażeniu suchej masy (LOI) / pozostałość po prażeniu Zakres: (5,0 – 90,0)% Metoda wagowa","methodology_en":"Loss on ignition of dry matter (LOI) / residue on ignition Range: (5,0 – 90,0)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strata przy prażeniu suchej masy (LOI) / pozostałość po prażeniu Zakres: (5,0 – 90,0)% Metoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 Strata przy prażeniu suchej masy (LOI) / pozostałość po prażeniu Zakres: (5,0 – 90,0)% Metoda wagowa PN-EN 15935:2022-01 Osady sciekowe Odpady O): kod 19 08 05 Strata przy prazeniu suchej masy (LOI) / pozostalosc po prazeniu Zakres: (5,0 – 90,0)% Metoda wagowa PN-EN 15935:2022-01","categories":["water","environment"],"row_index":80,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 Loss on ignition of dry matter (LOI) / residue on ignition Range: (5,0 – 90,0)% Gravimetric method PN-EN 15935:2022-01","search_zh":"污水污泥 废物 O)：代码 19 08 05 PN-EN 15935:2022-01","test_object_zh":"污水污泥 废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c1d","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe Odpady O): kod 19 08 05","test_object_en":"Sewage sludge Waste O): code 19 08 05","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp. Zakres: od 10 jaj ATT/kg s.m. Metoda mikroskopowa","methodology_en":"Presence and number of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Range: from 10 ATT eggs/kg d.m. Microscopic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp. Zakres: od 10 jaj ATT/kg s.m. Metoda mikroskopowa","reference":"PB-19/LO, wydanie 3 z dnia 01.08.2025 r.","norm_bases":["PB-19/LO, wydanie 3 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O): kod 19 08 05 Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp. Zakres: od 10 jaj ATT/kg s.m. Metoda mikroskopowa PB-19/LO, wydanie 3 z dnia 01.08.2025 r. Osady sciekowe Odpady O): kod 19 08 05 Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp., Toxocara sp., Trichuris sp. Zakres: od 10 jaj ATT/kg s.m. Metoda mikroskopowa PB-19/LO, wydanie 3 z dnia 01.08.2025 r.","categories":["water","environment"],"row_index":81,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O): code 19 08 05 Presence and number of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Range: from 10 ATT eggs/kg d.m. Microscopic method PB-19/LO, wydanie 3 z dnia 01.08.2025 r.","search_zh":"污水污泥 废物 O)：代码 19 08 05 PB-19/LO, wydanie 3 z dnia 01.08.2025 r.","test_object_zh":"污水污泥 废物 O)：代码 19 08 05"},{"_id":"6a5a56009af9f73f38253c1e","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A Zakres: (26 - 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (26 - 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (26 - 135) dB Metoda pomiarowa bezpośrednia","reference":"nr 7 | enia Ministra Klimatu i Środowiska z dn. 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punku F","norm_bases":["nr 7","enia Ministra Klimatu i Środowiska z dn. 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punku F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Zakres: (26 - 135) dB Metoda pomiarowa bezpośrednia nr 7 | enia Ministra Klimatu i Środowiska z dn. 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punku F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Zakres: (26 - 135) dB Metoda pomiarowa bezposrednia nr 7 | enia Ministra Klimatu i Srodowiska z dn. 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wylaczeniem punku F","categories":["environment"],"row_index":82,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (26 - 135) dB Direct measurement method nr 7 | enia Ministra Klimatu i Środowiska z dn. 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punku F","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 nr 7 | enia Ministra Klimatu i Środowiska z dn. 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punku F","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5a56009af9f73f38253c1f","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)","categories":["environment"],"row_index":83,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5a56009af9f73f38253c20","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − impulse noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A Zakres: (26 - 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (26 - 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (26 - 135) dB Metoda pomiarowa bezpośrednia","reference":"Nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023","norm_bases":["Nr 8","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Zakres: (26 - 135) dB Metoda pomiarowa bezpośrednia Nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 Srodowisko ogolne − halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Zakres: (26 - 135) dB Metoda pomiarowa bezposrednia Nr 8 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023","categories":["environment"],"row_index":84,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (26 - 135) dB Direct measurement method Nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 Nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a5a56009af9f73f38253c21","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − impulse noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Srodowisko ogolne − halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)","categories":["environment"],"row_index":85,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a5a56009af9f73f38253c22","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment − noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (26 - 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level Range: (26 - 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (26 - 135) dB Metoda pomiarowa bezpośrednia","reference":"Nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U.2011 nr 140 | nr 288 | eniem punktu H","norm_bases":["Nr 3","enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U.2011 nr 140","nr 288","eniem punktu H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (26 - 135) dB Metoda pomiarowa bezpośrednia Nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U.2011 nr 140 | nr 288 | eniem punktu H Srodowisko ogolne − halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A Zakres: (26 - 135) dB Metoda pomiarowa bezposrednia Nr 3 | enia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U.2011 nr 140 | nr 288 | eniem punktu H","categories":["environment"],"row_index":86,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (26 - 135) dB Direct measurement method Nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U.2011 nr 140 | nr 288 | eniem punktu H","search_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声 Nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U.2011 nr 140 | nr 288 | eniem punktu H","test_object_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5a56009af9f73f38253c23","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment − noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Srodowisko ogolne − halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)","categories":["environment"],"row_index":87,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","test_object_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5a56009af9f73f38253c24","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań fizycznych i chemicznych Metoda manualna Temperatura wody/pobranej próbki wody Zakres: (0,0 – 50,0) °C","methodology_en":"Sampling for physical and chemical testing Manual method Temperature of water/of the water sample taken Range: (0,0 – 50,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych Metoda manualna Temperatura wody/pobranej próbki wody Zakres: (0,0 – 50,0) °C","reference":"PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań fizycznych i chemicznych Metoda manualna Temperatura wody/pobranej próbki wody Zakres: (0,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584 Woda Pobieranie probek do badan fizycznych i chemicznych Metoda manualna Temperatura wody/pobranej probki wody Zakres: (0,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584","categories":["water"],"row_index":88,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for physical and chemical testing Manual method Temperature of water/of the water sample taken Range: (0,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584","search_zh":"水 PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584","test_object_zh":"水"},{"_id":"6a5a56009af9f73f38253c25","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań fizycznych i chemicznych Metoda manualna/ automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (0,0 – 50,0) °C","methodology_en":"Sampling for physical and chemical testing Manual/ automatic method Temperature of wastewater/of the wastewater sample taken Range: (0,0 – 50,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych Metoda manualna/ automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (0,0 – 50,0) °C","reference":"PN-ISO 5667-10:2021:11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021:11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań fizycznych i chemicznych Metoda manualna/ automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (0,0 – 50,0) °C PN-ISO 5667-10:2021:11 PN-77/C-04584 Scieki Pobieranie probek do badan fizycznych i chemicznych Metoda manualna/ automatyczna Temperatura sciekow/pobranej probki sciekow Zakres: (0,0 – 50,0) °C PN-ISO 5667-10:2021:11 PN-77/C-04584","categories":["water"],"row_index":89,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for physical and chemical testing Manual/ automatic method Temperature of wastewater/of the wastewater sample taken Range: (0,0 – 50,0) °C PN-ISO 5667-10:2021:11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021:11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a56009af9f73f38253c26","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda Scieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":90,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 废水 pH 范围：2,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水 废水","methodology_zh":"pH 范围：2,0 – 12,0 电位法"},{"_id":"6a5a56009af9f73f38253c27","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (10 - 20000) μS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10 - 20000) μS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 - 20000) μS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Przewodność elektryczna właściwa Zakres: (10 - 20000) μS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Scieki Przewodnosc elektryczna wlasciwa Zakres: (10 - 20000) μS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":91,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Electrical conductivity Range: (10 - 20000) μS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 废水 PN-EN 27888:1999","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c28","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie tlenu rozpuszczonego Zakres: (0,2 – 15,0) mg/l Metoda elektrochemiczna","methodology_en":"Dissolved oxygen concentration Range: (0,2 – 15,0) mg/l Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego Zakres: (0,2 – 15,0) mg/l Metoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie tlenu rozpuszczonego Zakres: (0,2 – 15,0) mg/l Metoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Scieki Stezenie tlenu rozpuszczonego Zakres: (0,2 – 15,0) mg/l Metoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":92,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Dissolved oxygen concentration Range: (0,2 – 15,0) mg/l Electrochemical method PN-EN ISO 5814:2013-04","search_zh":"水 废水 PN-EN ISO 5814:2013-04","test_object_zh":"水 废水"},{"_id":"6a5a56009af9f73f38253c29","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-4:2007 PN-ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 PN-ISO 10381-5:2009","categories":["environment"],"row_index":93,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 PN-ISO 10381-5:2009","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-4:2007 PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a5a56009af9f73f38253c2a","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05","test_object_en":"Sewage sludge, Waste O): code 19 08 05","methodology":"Pobieranie próbek do badań fizycznych, chemicznych i biologicznych","methodology_en":"Sampling for physical, chemical and biological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań fizycznych, chemicznych i biologicznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05 Pobieranie próbek do badań fizycznych, chemicznych i biologicznych PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3 Osady sciekowe, Odpady O): kod 19 08 05 Pobieranie probek do badan fizycznych, chemicznych i biologicznych PN-EN ISO 5667-13:2011 z wylaczeniem pkt 6.3.3","categories":["water","environment"],"row_index":94,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, Waste O): code 19 08 05 Sampling for physical, chemical and biological testing PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3"},{"_id":"6a5a56009af9f73f38253c2b","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości 50 Hz Zakres: 1,0 V/m – 50 kV/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range 50 Hz Range: 1,0 V/m – 50 kV/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości 50 Hz Zakres: 1,0 V/m – 50 kV/m Metoda pomiarowa bezpośrednia","reference":"enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","norm_bases":["enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego: - w zakresie częstotliwości 50 Hz Zakres: 1,0 V/m – 50 kV/m Metoda pomiarowa bezpośrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 Srodowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego: - w zakresie czestotliwosci 50 Hz Zakres: 1,0 V/m – 50 kV/m Metoda pomiarowa bezposrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","categories":["environment"],"row_index":95,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: - in the frequency range 50 Hz Range: 1,0 V/m – 50 kV/m Direct measurement method enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","search_zh":"环境 － 变电站与输电线路周围的电磁场 enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","test_object_zh":"环境 － 变电站与输电线路周围的电磁场"},{"_id":"6a5a56009af9f73f38253c2c","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Indukcja magnetyczna: - w zakresie częstotliwości 50 Hz Zakres 0,1 µT – 10 mT Metoda pomiarowa bezpośrednia","methodology_en":"Magnetic flux density: - in the frequency range 50 Hz Range 0,1 µT – 10 mT Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indukcja magnetyczna: - w zakresie częstotliwości 50 Hz Zakres 0,1 µT – 10 mT Metoda pomiarowa bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna: - w zakresie częstotliwości 50 Hz Zakres 0,1 µT – 10 mT Metoda pomiarowa bezpośrednia Srodowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna: - w zakresie czestotliwosci 50 Hz Zakres 0,1 µT – 10 mT Metoda pomiarowa bezposrednia","categories":["environment"],"row_index":96,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: - in the frequency range 50 Hz Range 0,1 µT – 10 mT Direct measurement method","search_zh":"环境 － 变电站与输电线路周围的电磁场","test_object_zh":"环境 － 变电站与输电线路周围的电磁场"},{"_id":"6a5a56009af9f73f38253c2d","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości 50 Hz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range 50 Hz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości 50 Hz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego: - w zakresie częstotliwości 50 Hz (z obliczeń) Srodowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego: - w zakresie czestotliwosci 50 Hz (z obliczen)","categories":["environment"],"row_index":97,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength: - in the frequency range 50 Hz (calculated)","search_zh":"环境 － 变电站与输电线路周围的电磁场 磁场强度：－ 频率 50 Hz 范围内（由计算得出）","test_object_zh":"环境 － 变电站与输电线路周围的电磁场","methodology_zh":"磁场强度：－ 频率 50 Hz 范围内（由计算得出）"},{"_id":"6a5a56009af9f73f38253c2e","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 10 MHz do 3 GHz Zakres: (0,3 – 300) V/m - w zakresie częstotliwości od 80 MHz do 60 GHz Zakres: (0,8 – 300) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range from 10 MHz to 3 GHz Range: (0,3 – 300) V/m - in the frequency range from 80 MHz to 60 GHz Range: (0,8 – 300) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 10 MHz do 3 GHz Zakres: (0,3 – 300) V/m - w zakresie częstotliwości od 80 MHz do 60 GHz Zakres: (0,8 – 300) V/m Metoda pomiarowa bezpośrednia","reference":"enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","norm_bases":["enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego: - w zakresie częstotliwości od 10 MHz do 3 GHz Zakres: (0,3 – 300) V/m - w zakresie częstotliwości od 80 MHz do 60 GHz Zakres: (0,8 – 300) V/m Metoda pomiarowa bezpośrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego: - w zakresie czestotliwosci od 10 MHz do 3 GHz Zakres: (0,3 – 300) V/m - w zakresie czestotliwosci od 80 MHz do 60 GHz Zakres: (0,8 – 300) V/m Metoda pomiarowa bezposrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","categories":["environment"],"row_index":98,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: - in the frequency range from 10 MHz to 3 GHz Range: (0,3 – 300) V/m - in the frequency range from 80 MHz to 60 GHz Range: (0,8 – 300) V/m Direct measurement method enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5a56009af9f73f38253c2f","lab_id":"69ad52a3de79e566650fb10f","country":"PL","accr_number":"AB 085","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range from 10 MHz to 60 GHz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń)","reference":"enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","norm_bases":["enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego: - w zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego: - w zakresie czestotliwosci od 10 MHz do 60 GHz (z obliczen) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","categories":["environment"],"row_index":99,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: - in the frequency range from 10 MHz to 60 GHz (calculated) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"}],"has_pdf":true}