🇵🇱 SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT ELEKTROTECHNIKI PL

PCA AB 067 • Warszawa, Poland • 87 methods

Materials & polymersConstructionMetrology & calibration

SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT ELEKTROTECHNIKI is a laboratory accredited by PCA under number AB 067 (Warszawa, Poland). Its accreditation scope covers 87 test methods in the following areas: Materials & polymers, Construction, Metrology & calibration. Test objects include: Composite, polymeric and organic materials insulators for nominal v…, Insulators for overhead lines with a nominal voltage above 1kV. Tra…, Voltage detectors - Capacitive type to be used for voltages exceedi…, Indoor and outdoor post insulators of ceramic material or glass for…. Most frequently used techniques: Dye penetration test / Dye penetration test, Lightning impulse withstand voltage tests / Lightning impulse withs…, Nominal power-frequency withstand voltage, dry test, 50 Hz.

At a glance

  • Accreditation number: PCA AB 067
  • Methods in scope: 87
  • Types of test objects: 18
  • Techniques used: 43
  • City: Warszawa, Poland
Accreditation number
AB 067
Accreditation body
PCA
Address
ŁUKASIEWICZ RESEARCH NETWORK – INSTITUTE OF ELECTRICAL, ENGINEERING, ul. Pożaryskiego 28, 04-703 Warszawa, CENTRUM BADAWCZE MATERIAŁÓW ELEKTROTECHNICZNYCH
City
Warszawa, Poland

What this laboratory tests (18)

Analytical techniques used (43)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (87)

No. Test object Methodology / Parameters Technique Reference document
Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics
1 Electrotechnical materials and products Fire Hazard Resistance
- Ignition and extinction time. - Flame height. - Ignition of the cotton pad.
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Glow Wire Method: PN-EN 60695-2-10:2013-12 | PN-EN 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN 60695-2-13:2022-05
2 Insulated cables, electric cables, fiber optic cables, heating cables Resistance to vertical flame spread: Fire hazard with a 1 kW mixed flame.
- Insulation charring range
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60332-1-1:2010 | PN-EN 60332-1-1:2010/A1:2016-02 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-2:2017-11
3 Solid electrotechnical insulating materials Flammability category testing. / Flammability category testing.
- Self-burn time - Glow time - Ignition of a cotton pad.
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Test methods using a 50 W flame test with the sample positioned horizontally and vertically. PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08
Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group
4 Electrotechnical materials and products Mechanical properties:
- proof yield strength (Rp) - apparent yield strength (Re) - tensile strength (Rm) - percentage elongation after fracture (A) - percentage reduction in area (Z) Range: force do 100 kN / up to 100 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Tensile test at room temperature PN-EN ISO 6892-1:2020-05
5 Electrotechnical materials and products Mechanical tensile, compressive, and flexural strength in the temperature range: (20 - 250) °C. (modulus of elasticity, compressive and tensile strength, lower and upper yield strength, elongation at break and yield strength)
Force range: rozciąganie i ściskanie do 100 kN, zginanie do 10 kN / tension and compression up to 100 kN, bending up to 10 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Ring Stiffness PN-EN ISO 604:2006 | PN-EN 60684-2:2011 | PN-EN ISO 527-1:2020-1 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-3:2019-01 | PN-EN ISO 527-4:2023-10 | PN-EN ISO 527-5:2022-06 | PN-ISO 37:2007+AC1:2008 | PN-EN 1228:1999 | PN-EN ISO 178:2019-06
6 Electrotechnical materials and products Tensile strength of coatings and insulation before and after aging of wires and cables
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Mechanical properties of wires PN-EN IEC 60851-3:2024-05 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02
7 Electrotechnical materials and products Breakdown voltage under normal conditions and as a function of temperature / Breakdown voltage under normal conditions and as a function of temperature
in the range (20 -180) °C / (20 - 180) °C up to 25 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60243-1:2013-12 | ASTM D149-20 | PN-EN 60464-2:2006 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60684-2:2011 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06
8 Electrotechnical materials and products Resistance under normal conditions and as a function of temperature
in the range of (20 - 180) °C Range: (0,0001 - 1015) Ω
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 62631-3-1:2023-10 | PN-EN IEC 62631-3-2:2024-07 | ASTM D257-14 (2021) e1 | PN-EN 62631-3-3:2016-08 | PN EN 60464-2:2006, p. 6.5.1 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60684-2:2011 p. 21, p. 22 i p. 23 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 62631-1:2011 | PN-EN 50395:2007, p. 5 | PN-EN 50395:2007/A1:2011
9 Electrotechnical products, materials, components, plastics and protective coatings Sunlight resistance
Temp.: / temp.: +40 C lub 55 C / +40 C or 55 C
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Test Sa PN-EN 60068-2-5:2011 | PN-EN ISO 4892-2:2013-06
10 Electrotechnical products, materials, components, plastics and protective coatings Environmental testing: Climate tests, change of temperature
Temperature range: (-65 - +90) C Relative air humidity range: (10 - 98)%
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60068-2-38:2010 | PN-EN 60068-2-38:2010/Ap1:2011 | PN-EN 60068-2-30:2008 | PN-EN 60068-2-2:2009 | PN-EN 60068-2-14:2009/Ap1:2016-07E | PN-EN 60068-2-14:2009 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-78:2013-11
11 Solid electrotechnical insulating materials Volume, surface, and insulation resistivity
at 23 C and in the temperature range: (–50 - +90) C, Measuring range: resistance – (10 - 1017) , resistivity – (10 - 1019) ·cm
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-88/E-04405 | IEC 60093:1980 | IEC 60167:1964 | ASTM D 257-99 | PN-EN 50395:2007 , p. 8 | PN-83/E-04160/73
12 Electrotechnical materials, components and devices (insulating materials and insulating parts of products) Electric strength of insulating materials: Tests at power frequencies
Range: 50 Hz ; 125 kV / 50 Hz; 125 kV And direct voltage do 30 kV / up to 30 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60243-2:2014-07 | PN-K-92001:1997, p. 2.7 i p. 3.8 | PN-EN 60243-1:2013-12
13 Insulating sticks and attachable devices under voltage up to 150 kV Torsion strength
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60832-1: 2010, p. 5.5.2, i p. 5.5.6
14 Insulating sticks and attachable devices under voltage up to 150 kV Tension strength
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60832-1: 2010, p. 5.5.3
15 Insulating sticks and attachable devices under voltage up to 150 kV Bending strength
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60832-1: 2010, p. 5.5.5
16 Insulating sticks and attachable devices under voltage up to 150 kV Electrical test after water conditioning
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60832-1: 2010, p. 5.7.1
17 Insulating sticks and attachable devices under voltage up to 150 kV Resistance solvent (only for measuring stick)
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60832-1: 2010, p. 5.8.8.1
18 Insulating sticks and attachable devices under voltage up to 150 kV Resistance to abrasion (only for measuring stick)
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60832-1: 2010, p. 5.8.8.2
19 Insulating sticks and attachable devices under voltage up to 150 kV Electric strength test after abrasion test
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60832-1: 2010, p. 5.8.8.3
20 Insulating tongs and grippers Linear dimensions
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PB-5/LB/IEL/OTiME p. 9.3, wyd. 5 z 02.03.2011
21 Insulating tongs and grippers Electrical strength of tongs
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PB-5/LB/IEL/OTiME p. 9.9, wyd. 5 z 02.03.2011
22 Electrical insulating matting Electrical tests
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 61111:2009 p. 5.6.
23 Gloves of insulating material Electrical tests with direct and alternating voltage / Live working
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60903:2006 p. 8.4
24 Insulating overboots and shoes Electrical strength and leakage current
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PB-13/LB/IEL/OTiME, wyd. 4 z 06.05.2008 | PN-EN 50321-1:2018-05
25 Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Threshold voltage / Threshold voltage
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN IEC 61243-1:2022-01
26 Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Time rating
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN IEC 61243-1:2022-01
27 Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Protection against bridging for indoor type/outdoor type voltage detector
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN IEC 61243-1:2022-01
28 Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Spark resistance
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN IEC 61243-1:2022-01
29 Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Drop resistance
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN IEC 61243-1:2022-01
30 Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Climatic dependence
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN IEC 61243-1:2022-01
31 Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Durability of markings
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN IEC 61243-1:2022-01
32 Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Testing of the influence of interfering factors on clear indication / Clear Indication: influence of in-phase interference field, opposite interference field and interference voltage
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN IEC 61243-1:2022-01
Electrotechnical Materials Testing Laboratory; Insulator Research Group
33 Ceramic and glass insulating materials Bulk density and open (apparent) porosity
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Hydrostatic method of weighting PN-EN 60672-2:2002 | PN-EN 60672-3:2002
34 Ceramic and glass insulating materials Mechanical flexural strength
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Triple point bending test PN-EN 60672-1:2010 | PN-EN 60672-2:2002 pkt. 6 | PN-EN 60672-3:2002
35 Ceramic and glass insulating materials Resistance to cracking
Range to 250 oC / 250 °C
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Resistance to thermal shock test PN-EN 60672-2:2002 | PN-EN 60672-3:2002
36 Ceramic and glass insulating materials Electric strength / Electric strength
Range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Measurements of the breakdown voltage PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12
37 Ceramic and glass insulating materials Withstand voltage / Withstand voltage,
Range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Test by withstand voltage. PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12
38 Ceramic and glass insulating materials Volume resistivity.
Range: (106 -1016) Ω·m / 106 – 1016 Ω·m
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60672-2:2002 | PN-EN 60672-3:2002
39 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Hardness test
range: do 100 ShA / to 100ShA
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Shore hardness test Shore A method PN-EN 62217:2013-06 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN ISO 868:2005
40 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Tracking and erosion test – 1000 h salt fog test
Range Up do 30 kV / to 30 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010
41 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Discontinuities / Porosity test (Dye penetration test)
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Dye penetration test / Dye penetration test PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010 | PN-EN ISO 3452-1:2021-12
42 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Water absorption/water penetration / Water diffusion test
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Water diffusion test PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010
43 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Thermal-mechanical pre-stressing – tensile strength / Thermal-mechanical pre-stress
tensile load: do 300 kN / to 300 kN - bending load Range: do 20 kN / to 20 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010
44 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Pre-stressing by water immersion / Water immersion pre-stressing
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 62217:2013-06
45 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Tightness between boundary surfaces test
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Dye penetration test / Dye penetration test PN-EN 61109:2010 | PN-EN ISO 3452-1:2013-08
46 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Verification of the dimensions / Verification of the dimensions
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010
47 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Thickness of the coating
Range: do 900 µm / to 900 μm
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Galvanizing test PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010 | PN-EN ISO 2178:2016-06
48 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Sudden load release
range: do 300 kN / to 300 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Sudden load release test PN-EN 61109:2010
49 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Mechanical strength Tensile load test
range: do 300 kN / to 300 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Determination of the average breaking tensile load PN-EN 61109:2010
50 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Tensile load test (96h test)
range: do 300 kN / to 300 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Multi-hour tensile load test (96h test) PN-EN 61109:2010
51 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Tensile strength / Tensile strength
range: do 300 kN / to 300 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Mechanical tensile load test / Mechanical tensile load test PN-EN 61109:2010 pkt. 13.1 | PN-EN 62231:2008 | PN-EN 60660:2002 | PN-EN 61952:2010
52 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Test for mechanical bending strength
range: do 25 kN / to 25 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Test for mechanical bending strength PN-EN 62231:2008 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN 60660:2002 | PN-EN 61952:2010
53 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Compressive strength test
Range: do 300 kN / to 300 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Compressive strength test PN-EN 62231:2008
54 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Bending strength / Bending Strength
Range: do 25 kN / up to 25 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Mechanical bending strength test as a function of temperature PN-EN 60660:2002
55 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Mechanical strength
Range: do 25 kN / up to 25 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Test for mechanical bending strength as a function of temperature PN-EN 60660:2002
56 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Reference dry power frequency test
range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Reference dry power frequency test PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 60060-1:2011
57 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Reference wet power frequency test
range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Reference wet power frequency test PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 62231:2008 | PN-EN 61952:2010
58 Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Impulse voltage test
range: (10 - 700) kV / 10 – 700 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Impulse voltage test PN-EN 62217:2013-06 | PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 61462:2009 | PN-EN 62231:2008 | PN-EN 61952:2010
59 Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Verification of the dimensions / Verification of the dimensions
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04
60 Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Electric strength.
Range: (10 - 700) kV / 10 – 700 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Lightning impulse withstand voltage tests / Lightning impulse withstand voltage tests PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04
61 Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Electric strength.
Range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Nominal power-frequency withstand voltage, dry and wet test, 50 Hz PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04
62 Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Electric strength.
Range: (10 - 700) kV / 10 – 700 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Impulse voltage puncture test in air. PN EN 61211:2005, | PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04
63 Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Resistance to thermal shock / Resistance to thermal shock
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04
64 Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Tensile strength / Tensile strength
Range: do 300 kN / to 300 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Thermomechanical test PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04
65 Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Mechanical strength test
- method of the test for line and line post insulators. - method of the test for long rod line insulators.
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04
66 Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Thickness of the coating.
Range: do 900 µm / to 900 μm
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Test of galvanization / Test of galvanization. PN-EN 60383-1:2005, | PN-EN ISO 2178:2016-06 | PN-EN 60383-1:2024-04
67 Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Verification of the dimensions / Verification of the dimensions
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60168:1999
68 Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Electric strength.
Range: (10 - 700) kV / 10 – 700 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Lightning impulse withstand voltage tests / Lightning impulse withstand voltage tests PN-EN 60168:1999 | PN-EN 60060-1:2011
69 Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Electric strength.
Range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Nominal power-frequency withstand voltage, dry test, 50 Hz PN-EN 60168:1999 | PN-EN 60060-1:2011
70 Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Electric strength.
Range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Nominal power-frequency withstand voltage, wet test, 50 Hz PN-EN 60168:1999 | PN-EN 60060-1:2011
71 Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Resistance to thermal shock / Resistance to thermal shock
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-EN 60168:1999
72 Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Bending strength / Bending strength.
Range: do 25 kN / to 25 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Mechanical bending strength test. PN-EN 60168:1999
73 Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Thickness of the coating
Range: do 900 µm / to 900 μm
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Test of galvanization / Test of galvanization. PN-EN 60168:1999 | PN-EN ISO 2178:2016-06
74 Low voltage power insulators – Ceramic insulators Verification of the dimensions / Verification of the dimensions
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-E-91030-1:1996
75 Low voltage power insulators – Ceramic insulators Verification of the weight
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-E-91030-1:1996
76 Low voltage power insulators – Ceramic insulators Resistance to thermal shock test
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
PN-E-91030-1:1996
77 Low voltage power insulators – Ceramic insulators Electric strength / Electric strength
Range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Nominal power-frequency withstand voltage, dry test, 50 Hz PN-E-91030-1:1996 | PN-EN 60060-1:2011
78 Low voltage power insulators – Ceramic insulators Electric strength.
Range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Nominal power-frequency withstand voltage, wet test, 50 Hz PN-E-91030-1:1996 | PN-EN 60060-1:2011
79 Low voltage power insulators – Ceramic insulators Tensile strength. Bending strength.
Range: do 25 kN / to 25 kN. Range: do 300 kN / to 300 kN.
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Mechanical bending strength test. Mechanical tensile strength test. PN-E-91030-1:1996
80 Low voltage power insulators – Ceramic insulators Cracks, inclusions, defects.
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Inspection of the fracture surface of ceramic body PN-E-91030-1:1996 | PN-E-91030-3:1997 | PN-E-91030-4:1997
81 Insulated bushings for alternating voltages above 1000V Electric strength.
Range: (10 - 700) kV / 10 – 700 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Lightning impulse withstand voltage tests PN-EN 60137:2018-02 | PN-EN 60060-1:2011
82 Insulated bushings for alternating voltages above 1000V Electric strength.
Range: (5 - 125) kV / 5 – 125 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Nominal power-frequency withstand voltage, dry or wet test, 50 Hz PN-EN 60137:2018-02 | PN-EN 60060-1:2011
83 Insulated bushings for alternating voltages above 1000V Bending strength / Bending strength.
Range: do 25 kN / to 25 kN.
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Mechanical bending strength test (only horizontal). PN-EN 60137:2018-02
84 Spark-free metal oxide surge arresters for AC networks Bending strength / Bending Strength
Range: do 25 kN / up to 25 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Bending Resistance Test PN-EN 60099-4:2015-01
85 Spark-free metal oxide surge arresters for AC networks Tensile Strength
Range: do 300 kN / up to 300 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Tensile Strength Test PN-EN 60099-4:2015-01
86 Spark-free metal oxide surge arresters for AC networks Mechanical resistance
Range: do 20 kN / up to 20 kN
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Thermomechanical stress PN-EN 60099-4:2015-01
87 Spark-free metal oxide surge arresters for AC networks Electrical Strength
Range: do 30 kV / up to 30 kV
Material / product tested (calculated), Type of activity/ parameter/ characteristic tested (calculated), Reference documents (calculated)
Aging in a Live Salt Spray Chamber PN-EN 60099-4:2015-01

Reference standards (117)

ASTM D 257-99
ASTM D149-20
ASTM D257-14 (2021) e1
IEC 60093:1980
IEC 60167:1964
PB-13/LB/IEL/OTiME, wyd. 4 z 06.05.2008
PB-5/LB/IEL/OTiME p. 9.3, wyd. 5 z 02.03.2011
PB-5/LB/IEL/OTiME p. 9.9, wyd. 5 z 02.03.2011
PN EN 60464-2:2006, p. 6.5.1
PN EN 61211:2005,
PN EN IEC 60455-2: 2024-04
PN-83/E-04160/73
PN-88/E-04405
PN-E-91030-1:1996
PN-E-91030-3:1997
PN-E-91030-4:1997
PN-EN 1228:1999
PN-EN 50321-1:2018-05
PN-EN 50395:2007 , p. 8
PN-EN 50395:2007, p. 5
PN-EN 50395:2007/A1:2011
PN-EN 60060-1:2011
PN-EN 60068-2-14:2009
PN-EN 60068-2-14:2009/Ap1:2016-07E
PN-EN 60068-2-1:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-30:2008
PN-EN 60068-2-38:2010
PN-EN 60068-2-38:2010/Ap1:2011
PN-EN 60068-2-5:2011
PN-EN 60068-2-78:2013-11
PN-EN 60099-4:2015-01
PN-EN 60137:2018-02
PN-EN 60168:1999
PN-EN 60243-1:2013-12
PN-EN 60243-2:2014-07
PN-EN 60332-1-1:2010
PN-EN 60332-1-1:2010/A1:2016-02
PN-EN 60332-1-2:2010
PN-EN 60332-1-2:2010/A11:2017-02
PN-EN 60332-1-2:2010/A12:2021-05
PN-EN 60332-1-2:2010/A1:2016-02
PN-EN 60332-2-2:2010
PN-EN 60383-1:2005
PN-EN 60383-1:2005,
PN-EN 60383-1:2024-04
PN-EN 60454-2:2008
PN-EN 60464-2:2006
PN-EN 60464-2:2006/A1:2008
PN-EN 60660:2002
PN-EN 60672-1:2010
PN-EN 60672-2:2002
PN-EN 60672-2:2002 pkt. 6
PN-EN 60672-3:2002
PN-EN 60674-2:2017-04
PN-EN 60674-2:2017-04/A1:2019-06
PN-EN 60684-2:2011
PN-EN 60684-2:2011 p. 21, p. 22 i p. 23
PN-EN 60695-11-10:2014-02
PN-EN 60695-11-10:2014-02/AC:2017-08
PN-EN 60695-11-2:2017-11
PN-EN 60695-2-10:2013-12
PN-EN 60695-2-10:2022-07
PN-EN 60695-2-11:2015-02
PN-EN 60695-2-11:2022-07
PN-EN 60695-2-12:2011
PN-EN 60695-2-12:2011/A1:2014-10
PN-EN 60695-2-12:2022-06
PN-EN 60695-2-13:2011
PN-EN 60695-2-13:2011/A1:2014-10
PN-EN 60695-2-13:2022-05
PN-EN 60811-401:2012
PN-EN 60811-401:2012/A1:2018-02
PN-EN 60811-501:2012
PN-EN 60811-501:2012/A1:2019-01
PN-EN 60811-501:2012/A2:2024-03
PN-EN 60832-1: 2010, p. 5.5.2, i p. 5.5.6
PN-EN 60832-1: 2010, p. 5.5.3
PN-EN 60832-1: 2010, p. 5.5.5
PN-EN 60832-1: 2010, p. 5.7.1
PN-EN 60832-1: 2010, p. 5.8.8.1
PN-EN 60832-1: 2010, p. 5.8.8.2
PN-EN 60832-1: 2010, p. 5.8.8.3
PN-EN 60851-5:2008
PN-EN 60851-5:2008/A1:2011
PN-EN 60851-5:2008/A2:2020-06
PN-EN 60903:2006 p. 8.4
PN-EN 61109:2010
PN-EN 61109:2010 pkt. 13.1
PN-EN 61111:2009 p. 5.6.
PN-EN 61462:2009
PN-EN 61952:2010
PN-EN 62217:2013-06
PN-EN 62217:2013-06 pkt. 9.3.1.
PN-EN 62231:2008
PN-EN 62231:2008 pkt. 9.3.1.
PN-EN 62631-1:2011
PN-EN 62631-3-1:2023-10
PN-EN 62631-3-3:2016-08
PN-EN IEC 60851-3:2024-05
PN-EN IEC 61243-1:2022-01
PN-EN IEC 62631-3-2:2024-07
PN-EN ISO 178:2019-06
PN-EN ISO 2178:2016-06
PN-EN ISO 3452-1:2013-08
PN-EN ISO 3452-1:2021-12
PN-EN ISO 4892-2:2013-06
PN-EN ISO 527-1:2020-1
PN-EN ISO 527-2:2012
PN-EN ISO 527-3:2019-01
PN-EN ISO 527-4:2023-10
PN-EN ISO 527-5:2022-06
PN-EN ISO 604:2006
PN-EN ISO 6892-1:2020-05
PN-EN ISO 868:2005
PN-ISO 37:2007+AC1:2008
PN-K-92001:1997, p. 2.7 i p. 3.8