{"lab":{"_id":"69ad52a3de79e566650fb0fb","accr_number":"AB 067","country":"PL","accr_body":"PCA","address":"ŁUKASIEWICZ RESEARCH NETWORK – INSTITUTE OF ELECTRICAL, ENGINEERING, ul. Pożaryskiego 28, 04-703 Warszawa, CENTRUM BADAWCZE MATERIAŁÓW ELEKTROTECHNICZNYCH","categories":["materials","construction"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":87,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT ELEKTROTECHNIKI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_067.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - instytut elektrotechniki łukasiewicz research network – institute of electrical, engineering, ul. pożaryskiego 28, 04-703 warszawa, centrum badawcze materiałów elektrotechnicznych materials pharma other water electronics construction environment metrology","status":"active","updated_at":"2026-03-08T14:50:08.083Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:43:16.151Z","parse_date":"2026-08-13T07:43:16.151Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20067,podmiot.html","fields_of_testing":[{"codes":"E/6; E/8; E/12; E/19; E/21; E/53","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, szkła i ceramiki, środków ochrony osobistej, wyrobów z tworzyw sztucznych i gumy, wyrobów i wyposażenia telekomunikacyjnego","en":"Electric and electronic tests of electrical and electronic products and equipment, construction products and materials, glass and ceramics, personal protection equipment plastic and rubber products, telecommunication products and equipment"},{"codes":"H/6; H/8; H/19; H/21; H/53; H/54","pl":"Badania ogniowe wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, środków ochrony osobistej, wyrobów z tworzyw sztucznych i gumy, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Fire tests of electrical products and equipment, construction products and materials, personal protection equipment, plastic and rubber products, telecommunication products and equipment, electronic products and equipment"},{"codes":"J/6; J/8; J/12; J/19; J/21; J/53; J/54","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, szkła i ceramiki, środków ochrony osobistej, wyrobów z tworzyw sztucznych i gumy, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Mechanical tests of electrical products and equipment, construction products and materials, glass and ceramics, personal protection equipment, plastic and rubber products, telecommunication products and equipment, electronic products and equipment"},{"codes":"L/6; L/8; L/12; L/53; L/54","pl":"Badania nieniszczące wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, szkła i ceramiki, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Non-destructive tests of electrical products and equipment, construction products and materials, glass and ceramics, , telecommunication products and equipment, electronic products and equipment"},{"codes":"N/6; N/8; N/12; N/19; N/21; N/53; N/54","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, szkła i ceramiki, środków ochrony osobistej, wyrobów z tworzyw sztucznych i gumy, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Tests of physical properties of electrical products and equipment, construction products and materials, glass and ceramics, personal protection equipment, plastic and rubber products, , telecommunication products and equipment, electronic products and equipment"}],"issue":{"no":"25","date":"27.07.2026"},"map_coord":[52.207157,21.173926],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE MATERIAŁÓW ELEKTROTECHNICZNYCH / ELECTROTECHNICAL MATERIALS TESTING LABORATORY","address":"ul. M. Skłodowskiej-Curie 55/61; 50-369 Wrocław","city":"Wrocław","postal":"50-369"},{"name":"Zespół badania zagrożeń ogniowych i palności materiałów elektrotechnicznych oraz tworzyw sztucznych / Fire hazard and flammability testing group of electrotechn","address":"ul. M. Skłodowskiej-Curie 55/61; 50-369 Wrocław","city":"Wrocław","postal":"50-369"},{"name":"Zespół badania materiałów i wyrobów elektrotechnicznych / Electrotechnical Materials and Products Research Group","address":"ul. M. Skłodowskiej-Curie 55/61; 50-369 Wrocław","city":"Wrocław","postal":"50-369"},{"name":"Zespół Badania Izolatorów / Insulator Research Group","address":"ul. M. Skłodowskiej-Curie 55/61; 50-369 Wrocław","city":"Wrocław","postal":"50-369"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/812229c44618f1123172efcbc48e59a1/AB%20067.pdf","has_en":true,"category_counts":{"materials":50,"other":28,"construction":13,"water":3,"environment":1},"category_scores":{"materials":26.32,"other":8.25,"construction":1.78,"water":0.09,"environment":0.01},"has_zh":true},"methods":[{"_id":"6a7d7594441eff5f1564877f","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products","methodology":"Odporność na zagrożenie ogniowe / Fire Hazard Resistance","parameters":[{"name":"- Czas zapalenia i gaśnięcia. / - Ignition and extinction time."},{"name":"- Wysokość płomienia. / - Flame height."},{"name":"- Zapalenie bawełnianej podkładki. / - Ignition of the cotton pad."}],"technique":"Metoda rozżarzonego drutu: / Glow Wire Method:","techniques":["Metoda rozżarzonego drutu: / Glow Wire Method:"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na zagrożenie ogniowe / Fire Hazard Resistance\nZakres:\n- Czas zapalenia i gaśnięcia. / - Ignition and extinction time.\n- Wysokość płomienia. / - Flame height.\n- Zapalenie bawełnianej podkładki. / - Ignition of the cotton pad.\nMetoda rozżarzonego drutu: / Glow Wire Method:","reference":"PN-EN 60695-2-10:2013-12 | PN-EN 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN 60695-2-13:2022-05","norm_bases":["PN-EN 60695-2-10:2013-12","PN-EN 60695-2-10:2022-07","PN-EN 60695-2-11:2015-02","PN-EN 60695-2-11:2022-07","PN-EN 60695-2-12:2011","PN-EN 60695-2-12:2011/A1:2014-10","PN-EN 60695-2-12:2022-06","PN-EN 60695-2-13:2011","PN-EN 60695-2-13:2011/A1:2014-10","PN-EN 60695-2-13:2022-05"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania zagrożeń ogniowych i palności materiałów elektrotechnicznych oraz tworzyw sztucznych; Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products Odporność na zagrożenie ogniowe / Fire Hazard Resistance\nZakres:\n- Czas zapalenia i gaśnięcia. / - Ignition and extinction time.\n- Wysokość płomienia. / - Flame height.\n- Zapalenie bawełnianej podkładki. / - Ignition of the cotton pad.\nMetoda rozżarzonego drutu: / Glow Wire Method: PN-EN 60695-2-10:2013-12 | PN-EN 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN 60695-2-13:2022-05 Materialy i wyroby elektrotechniczne / Electrotechnical materials and products Odpornosc na zagrozenie ogniowe / Fire Hazard Resistance\nZakres:\n- Czas zapalenia i gasniecia. / - Ignition and extinction time.\n- Wysokosc plomienia. / - Flame height.\n- Zapalenie bawelnianej podkladki. / - Ignition of the cotton pad.\nMetoda rozzarzonego drutu: / Glow Wire Method: PN-EN 60695-2-10:2013-12 | PN-EN 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN 60695-2-13:2022-05","categories":["materials"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics","methodology_en":"Fire Hazard Resistance","parameters_en":[{"name":"- Ignition and extinction time."},{"name":"- Flame height."},{"name":"- Ignition of the cotton pad."}],"search_en":"Electrotechnical materials and products Fire Hazard Resistance Glow Wire Method: Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics - Ignition and extinction time. - Flame height. - Ignition of the cotton pad. Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60695-2-10:2013-12 | PN-EN 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN 60695-2-13:2022-05","technique_en":"Glow Wire Method:","test_object_en":"Electrotechnical materials and products","search_zh":"电工材料与制品 / Electrotechnical materials and products 电工材料检测实验室；电工材料与塑料火灾危险与燃烧性检验组 Electrotechnical Materials Testing Laboratory PN-EN 60695-2-10:2013-12 | PN-EN 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN 60695-2-13:2022-05","test_object_zh":"电工材料与制品 / Electrotechnical materials and products","lab_section_zh":"电工材料检测实验室；电工材料与塑料火灾危险与燃烧性检验组 Electrotechnical Materials Testing Laboratory"},{"_id":"6a7d7594441eff5f15648780","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Przewody izolowane, kable elektryczne, kable światłowodowe, przewody grzejne / Insulated cables, electric cables, fiber optic cables, heating cables","methodology":"Odporność na pionowe rozprzestrzenianie płomienia: Zagrożenie ogniowe płomieniem mieszankowym 1 kW. / Resistance to vertical flame spread: Fire hazard with a 1 kW mixed flame.","parameters":[{"name":"- Zasięg zwęglenia izolacji / - Insulation charring range"}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na pionowe rozprzestrzenianie płomienia: Zagrożenie ogniowe płomieniem mieszankowym 1 kW. / Resistance to vertical flame spread: Fire hazard with a 1 kW mixed flame.\n- Zasięg zwęglenia izolacji / - Insulation charring range","reference":"PN-EN 60332-1-1:2010 | PN-EN 60332-1-1:2010/A1:2016-02 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-2:2017-11","norm_bases":["PN-EN 60332-1-1:2010","PN-EN 60332-1-1:2010/A1:2016-02","PN-EN 60332-1-2:2010","PN-EN 60332-1-2:2010/A1:2016-02","PN-EN 60332-1-2:2010/A11:2017-02","PN-EN 60332-1-2:2010/A12:2021-05","PN-EN 60332-2-2:2010","PN-EN 60695-11-2:2017-11"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania zagrożeń ogniowych i palności materiałów elektrotechnicznych oraz tworzyw sztucznych; Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przewody izolowane, kable elektryczne, kable światłowodowe, przewody grzejne / Insulated cables, electric cables, fiber optic cables, heating cables Odporność na pionowe rozprzestrzenianie płomienia: Zagrożenie ogniowe płomieniem mieszankowym 1 kW. / Resistance to vertical flame spread: Fire hazard with a 1 kW mixed flame.\n- Zasięg zwęglenia izolacji / - Insulation charring range PN-EN 60332-1-1:2010 | PN-EN 60332-1-1:2010/A1:2016-02 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-2:2017-11 Przewody izolowane, kable elektryczne, kable swiatlowodowe, przewody grzejne / Insulated cables, electric cables, fiber optic cables, heating cables Odpornosc na pionowe rozprzestrzenianie plomienia: Zagrozenie ogniowe plomieniem mieszankowym 1 kW. / Resistance to vertical flame spread: Fire hazard with a 1 kW mixed flame.\n- Zasieg zweglenia izolacji / - Insulation charring range PN-EN 60332-1-1:2010 | PN-EN 60332-1-1:2010/A1:2016-02 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-2:2017-11","categories":["construction","materials"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics","methodology_en":"Resistance to vertical flame spread: Fire hazard with a 1 kW mixed flame.","parameters_en":[{"name":"- Insulation charring range"}],"search_en":"Insulated cables, electric cables, fiber optic cables, heating cables Resistance to vertical flame spread: Fire hazard with a 1 kW mixed flame. Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics - Insulation charring range Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60332-1-1:2010 | PN-EN 60332-1-1:2010/A1:2016-02 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-2:2017-11","test_object_en":"Insulated cables, electric cables, fiber optic cables, heating cables","lab_section_zh":"电工材料检测实验室；电工材料与塑料火灾危险与燃烧性检验组 Electrotechnical Materials Testing Laboratory","search_zh":"电工材料检测实验室；电工材料与塑料火灾危险与燃烧性检验组 Electrotechnical Materials Testing Laboratory PN-EN 60332-1-1:2010 | PN-EN 60332-1-1:2010/A1:2016-02 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-2:2017-11"},{"_id":"6a7d7594441eff5f15648781","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały elektroizolacyjne stałe / Solid electrotechnical insulating materials","methodology":"Badanie kategorii palności. / Flammability category testing.","parameters":[{"name":"- Czas palenia się płomieniem własnym / - Self-burn time"},{"name":"- Czas żarzenia się / - Glow time"},{"name":"- Zapalenie podkładki bawełnianej. / - Ignition of a cotton pad."}],"technique":"Metody badań płomieniem probierczym 50 W przy poziomym i pionowym ustawieniu próbki. / Test methods using a 50 W flame test with the sample positioned horizontally and vertically.","techniques":["Metody badań płomieniem probierczym 50 W przy poziomym i pionowym ustawieniu próbki. / Test methods using a 50 W flame test with the sample positioned horizontally and vertically."],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Badanie kategorii palności. / Flammability category testing.\nZakres:\n- Czas palenia się płomieniem własnym / - Self-burn time\n- Czas żarzenia się / - Glow time\n- Zapalenie podkładki bawełnianej. / - Ignition of a cotton pad.\nMetody badań płomieniem probierczym 50 W przy poziomym i pionowym ustawieniu próbki. / Test methods using a 50 W flame test with the sample positioned horizontally and vertically.","reference":"PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08","norm_bases":["PN-EN 60695-11-10:2014-02","PN-EN 60695-11-10:2014-02/AC:2017-08"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania zagrożeń ogniowych i palności materiałów elektrotechnicznych oraz tworzyw sztucznych; Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały elektroizolacyjne stałe / Solid electrotechnical insulating materials Badanie kategorii palności. / Flammability category testing.\nZakres:\n- Czas palenia się płomieniem własnym / - Self-burn time\n- Czas żarzenia się / - Glow time\n- Zapalenie podkładki bawełnianej. / - Ignition of a cotton pad.\nMetody badań płomieniem probierczym 50 W przy poziomym i pionowym ustawieniu próbki. / Test methods using a 50 W flame test with the sample positioned horizontally and vertically. PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08 Materialy elektroizolacyjne stale / Solid electrotechnical insulating materials Badanie kategorii palnosci. / Flammability category testing.\nZakres:\n- Czas palenia sie plomieniem wlasnym / - Self-burn time\n- Czas zarzenia sie / - Glow time\n- Zapalenie podkladki bawelnianej. / - Ignition of a cotton pad.\nMetody badan plomieniem probierczym 50 W przy poziomym i pionowym ustawieniu probki. / Test methods using a 50 W flame test with the sample positioned horizontally and vertically. PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08","categories":["materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics","methodology_en":"Flammability category testing. / Flammability category testing.","parameters_en":[{"name":"- Self-burn time"},{"name":"- Glow time"},{"name":"- Ignition of a cotton pad."}],"search_en":"Solid electrotechnical insulating materials Flammability category testing. / Flammability category testing. Test methods using a 50 W flame test with the sample positioned horizontally and vertically. Electrotechnical Materials Testing Laboratory; Fire hazard and flammability testing group of electrotechnical materials and plastics - Self-burn time - Glow time - Ignition of a cotton pad. Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08","technique_en":"Test methods using a 50 W flame test with the sample positioned horizontally and vertically.","test_object_en":"Solid electrotechnical insulating materials","lab_section_zh":"电工材料检测实验室；电工材料与塑料火灾危险与燃烧性检验组 Electrotechnical Materials Testing Laboratory","search_zh":"电工材料检测实验室；电工材料与塑料火灾危险与燃烧性检验组 Electrotechnical Materials Testing Laboratory PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08"},{"_id":"6a7d7594441eff5f15648782","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products","methodology":"Własności mechaniczne: / Mechanical properties:","parameters":[{"name":"- umowna granica plastyczności (Rp) / - yield strength (Rp)"},{"name":"- wyraźna granica plastyczności (Re) / - apparent yield strength (Re)"},{"name":"- wytrzymałość na rozciąganie (Rm) / - tensile strength (Rm)"},{"name":"- wydłużenie procentowe po rozerwaniu (A) / - percentage elongation after fracture (A)"},{"name":"- przewężenie procentowe (Z) / - percentage reduction in area (Z)"},{"name":"Zakres: siła / Range: force","range":"do 100 kN / up to 100 kN"}],"technique":"Próba rozciągania w temperaturze Pokojowej / Tensile test at room temperature","techniques":["Próba rozciągania w temperaturze Pokojowej / Tensile test at room temperature"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Własności mechaniczne: / Mechanical properties:\nZakres:\n- umowna granica plastyczności (Rp) / - yield strength (Rp)\n- wyraźna granica plastyczności (Re) / - apparent yield strength (Re)\n- wytrzymałość na rozciąganie (Rm) / - tensile strength (Rm)\n- wydłużenie procentowe po rozerwaniu (A) / - percentage elongation after fracture (A)\n- przewężenie procentowe (Z) / - percentage reduction in area (Z)\nZakres: siła / Range: force do 100 kN / up to 100 kN\nPróba rozciągania w temperaturze Pokojowej / Tensile test at room temperature","reference":"PN-EN ISO 6892-1:2020-05","norm_bases":["PN-EN ISO 6892-1:2020-05"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products Własności mechaniczne: / Mechanical properties:\nZakres:\n- umowna granica plastyczności (Rp) / - yield strength (Rp)\n- wyraźna granica plastyczności (Re) / - apparent yield strength (Re)\n- wytrzymałość na rozciąganie (Rm) / - tensile strength (Rm)\n- wydłużenie procentowe po rozerwaniu (A) / - percentage elongation after fracture (A)\n- przewężenie procentowe (Z) / - percentage reduction in area (Z)\nZakres: siła / Range: force do 100 kN / up to 100 kN\nPróba rozciągania w temperaturze Pokojowej / Tensile test at room temperature PN-EN ISO 6892-1:2020-05 Materialy i wyroby elektrotechniczne / Electrotechnical materials and products Wlasnosci mechaniczne: / Mechanical properties:\nZakres:\n- umowna granica plastycznosci (Rp) / - yield strength (Rp)\n- wyrazna granica plastycznosci (Re) / - apparent yield strength (Re)\n- wytrzymalosc na rozciaganie (Rm) / - tensile strength (Rm)\n- wydluzenie procentowe po rozerwaniu (A) / - percentage elongation after fracture (A)\n- przewezenie procentowe (Z) / - percentage reduction in area (Z)\nZakres: sila / Range: force do 100 kN / up to 100 kN\nProba rozciagania w temperaturze Pokojowej / Tensile test at room temperature PN-EN ISO 6892-1:2020-05","categories":["materials"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Mechanical properties:","parameters_en":[{"name":"- proof yield strength (Rp)"},{"name":"- apparent yield strength (Re)"},{"name":"- tensile strength (Rm)"},{"name":"- percentage elongation after fracture (A)"},{"name":"- percentage reduction in area (Z)"},{"name":"Range: force","range":"do 100 kN / up to 100 kN"}],"search_en":"Electrotechnical materials and products Mechanical properties: Tensile test at room temperature Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group - proof yield strength (Rp) - apparent yield strength (Re) - tensile strength (Rm) - percentage elongation after fracture (A) - percentage reduction in area (Z) Range: force Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN ISO 6892-1:2020-05","technique_en":"Tensile test at room temperature","test_object_en":"Electrotechnical materials and products","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料与制品 / Electrotechnical materials and products 力学性能：/ Mechanical properties: 电工材料检测实验室；电工材料与制品研究组 PN-EN ISO 6892-1:2020-05","test_object_zh":"电工材料与制品 / Electrotechnical materials and products","methodology_zh":"力学性能：/ Mechanical properties:"},{"_id":"6a7d7594441eff5f15648783","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products","methodology":"Wytrzymałość mechaniczna na rozciąganie, ściskanie i zginanie w zakresie temperatur: (20 - 250) °C. (moduł sprężystości, wytrzymałość na ściskanie i zerwanie, dolna i górna granica plastyczności, wydłużenie przy zerwaniu i granicy plastyczności) / Mechanical tensile, compressive, and flexural strength in the temperature range: (20 - 250) °C. (modulus of elasticity, compressive and tensile strength, lower and upper yield strength, elongation at break and yield strength)","parameters":[{"name":"Zakres siły: / Force range:","range":"rozciąganie i ściskanie do 100 kN, zginanie do 10 kN / tension and compression up to 100 kN, bending up to 10 kN"}],"technique":"Sztywność obwodowa / Ring Stiffness","techniques":["Sztywność obwodowa / Ring Stiffness"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość mechaniczna na rozciąganie, ściskanie i zginanie w zakresie temperatur: (20 - 250) °C. (moduł sprężystości, wytrzymałość na ściskanie i zerwanie, dolna i górna granica plastyczności, wydłużenie przy zerwaniu i granicy plastyczności) / Mechanical tensile, compressive, and flexural strength in the temperature range: (20 - 250) °C. (modulus of elasticity, compressive and tensile strength, lower and upper yield strength, elongation at break and yield strength)\nZakres siły: / Force range: rozciąganie i ściskanie do 100 kN, zginanie do 10 kN / tension and compression up to 100 kN, bending up to 10 kN\nSztywność obwodowa / Ring Stiffness","reference":"PN-EN ISO 604:2006 | PN-EN 60684-2:2011 | PN-EN ISO 527-1:2020-1 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-3:2019-01 | PN-EN ISO 527-4:2023-10 | PN-EN ISO 527-5:2022-06 | PN-ISO 37:2007+AC1:2008 | PN-EN 1228:1999 | PN-EN ISO 178:2019-06","norm_bases":["PN-EN ISO 604:2006","PN-EN 60684-2:2011","PN-EN ISO 527-1:2020-1","PN-EN ISO 527-2:2012","PN-EN ISO 527-3:2019-01","PN-EN ISO 527-4:2023-10","PN-EN ISO 527-5:2022-06","PN-ISO 37:2007+AC1:2008","PN-EN 1228:1999","PN-EN ISO 178:2019-06"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products Wytrzymałość mechaniczna na rozciąganie, ściskanie i zginanie w zakresie temperatur: (20 - 250) °C. (moduł sprężystości, wytrzymałość na ściskanie i zerwanie, dolna i górna granica plastyczności, wydłużenie przy zerwaniu i granicy plastyczności) / Mechanical tensile, compressive, and flexural strength in the temperature range: (20 - 250) °C. (modulus of elasticity, compressive and tensile strength, lower and upper yield strength, elongation at break and yield strength)\nZakres siły: / Force range: rozciąganie i ściskanie do 100 kN, zginanie do 10 kN / tension and compression up to 100 kN, bending up to 10 kN\nSztywność obwodowa / Ring Stiffness PN-EN ISO 604:2006 | PN-EN 60684-2:2011 | PN-EN ISO 527-1:2020-1 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-3:2019-01 | PN-EN ISO 527-4:2023-10 | PN-EN ISO 527-5:2022-06 | PN-ISO 37:2007+AC1:2008 | PN-EN 1228:1999 | PN-EN ISO 178:2019-06 Materialy i wyroby elektrotechniczne / Electrotechnical materials and products Wytrzymalosc mechaniczna na rozciaganie, sciskanie i zginanie w zakresie temperatur: (20 - 250) °C. (modul sprezystosci, wytrzymalosc na sciskanie i zerwanie, dolna i gorna granica plastycznosci, wydluzenie przy zerwaniu i granicy plastycznosci) / Mechanical tensile, compressive, and flexural strength in the temperature range: (20 - 250) °C. (modulus of elasticity, compressive and tensile strength, lower and upper yield strength, elongation at break and yield strength)\nZakres sily: / Force range: rozciaganie i sciskanie do 100 kN, zginanie do 10 kN / tension and compression up to 100 kN, bending up to 10 kN\nSztywnosc obwodowa / Ring Stiffness PN-EN ISO 604:2006 | PN-EN 60684-2:2011 | PN-EN ISO 527-1:2020-1 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-3:2019-01 | PN-EN ISO 527-4:2023-10 | PN-EN ISO 527-5:2022-06 | PN-ISO 37:2007+AC1:2008 | PN-EN 1228:1999 | PN-EN ISO 178:2019-06","categories":["materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Mechanical tensile, compressive, and flexural strength in the temperature range: (20 - 250) °C. (modulus of elasticity, compressive and tensile strength, lower and upper yield strength, elongation at break and yield strength)","parameters_en":[{"name":"Force range:","range":"rozciąganie i ściskanie do 100 kN, zginanie do 10 kN / tension and compression up to 100 kN, bending up to 10 kN"}],"search_en":"Electrotechnical materials and products Mechanical tensile, compressive, and flexural strength in the temperature range: (20 - 250) °C. (modulus of elasticity, compressive and tensile strength, lower and upper yield strength, elongation at break and yield strength) Ring Stiffness Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Force range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN ISO 604:2006 | PN-EN 60684-2:2011 | PN-EN ISO 527-1:2020-1 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-3:2019-01 | PN-EN ISO 527-4:2023-10 | PN-EN ISO 527-5:2022-06 | PN-ISO 37:2007+AC1:2008 | PN-EN 1228:1999 | PN-EN ISO 178:2019-06","technique_en":"Ring Stiffness","test_object_en":"Electrotechnical materials and products","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料与制品 / Electrotechnical materials and products 电工材料检测实验室；电工材料与制品研究组 PN-EN ISO 604:2006 | PN-EN 60684-2:2011 | PN-EN ISO 527-1:2020-1 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-3:2019-01 | PN-EN ISO 527-4:2023-10 | PN-EN ISO 527-5:2022-06 | PN-ISO 37:2007+AC1:2008 | PN-EN 1228:1999 | PN-EN ISO 178:2019-06","test_object_zh":"电工材料与制品 / Electrotechnical materials and products"},{"_id":"6a7d7594441eff5f15648784","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products","methodology":"Odporność powłoki i izolacji na rozciąganie przed i po starzeniu przewodów i kabli / Tensile strength of coatings and insulation before and after aging of wires and cables","parameters":[],"technique":"Właściwości mechaniczne przewodów / Mechanical properties of wires","techniques":["Właściwości mechaniczne przewodów / Mechanical properties of wires"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność powłoki i izolacji na rozciąganie przed i po starzeniu przewodów i kabli / Tensile strength of coatings and insulation before and after aging of wires and cables\nWłaściwości mechaniczne przewodów / Mechanical properties of wires","reference":"PN-EN IEC 60851-3:2024-05 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02","norm_bases":["PN-EN IEC 60851-3:2024-05","PN-EN 60811-501:2012","PN-EN 60811-501:2012/A1:2019-01","PN-EN 60811-501:2012/A2:2024-03","PN-EN 60811-401:2012","PN-EN 60811-401:2012/A1:2018-02"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products Odporność powłoki i izolacji na rozciąganie przed i po starzeniu przewodów i kabli / Tensile strength of coatings and insulation before and after aging of wires and cables\nWłaściwości mechaniczne przewodów / Mechanical properties of wires PN-EN IEC 60851-3:2024-05 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02 Materialy i wyroby elektrotechniczne / Electrotechnical materials and products Odpornosc powloki i izolacji na rozciaganie przed i po starzeniu przewodow i kabli / Tensile strength of coatings and insulation before and after aging of wires and cables\nWlasciwosci mechaniczne przewodow / Mechanical properties of wires PN-EN IEC 60851-3:2024-05 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02","categories":["materials","construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Tensile strength of coatings and insulation before and after aging of wires and cables","search_en":"Electrotechnical materials and products Tensile strength of coatings and insulation before and after aging of wires and cables Mechanical properties of wires Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 60851-3:2024-05 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02","technique_en":"Mechanical properties of wires","test_object_en":"Electrotechnical materials and products","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料与制品 / Electrotechnical materials and products 电工材料检测实验室；电工材料与制品研究组 PN-EN IEC 60851-3:2024-05 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02","test_object_zh":"电工材料与制品 / Electrotechnical materials and products"},{"_id":"6a7d7594441eff5f15648785","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products","methodology":"Napięcie przebicia w warunkach normalnych i w funkcji temperatury / Breakdown voltage under normal conditions and as a function of temperature","parameters":[{"name":"w przedziale / in the range","range":"(20 -180) °C / (20 - 180) °C"},{"name":"do 25 kV / up to 25 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Napięcie przebicia w warunkach normalnych i w funkcji temperatury / Breakdown voltage under normal conditions and as a function of temperature\nZakres:\nw przedziale / in the range (20 -180) °C / (20 - 180) °C\ndo 25 kV / up to 25 kV","reference":"PN-EN 60243-1:2013-12 | ASTM D149-20 | PN-EN 60464-2:2006 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60684-2:2011 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06","norm_bases":["PN-EN 60243-1:2013-12","ASTM D149-20","PN-EN 60464-2:2006","PN-EN 60464-2:2006/A1:2008","PN EN IEC 60455-2: 2024-04","PN-EN 60674-2:2017-04","PN-EN 60674-2:2017-04/A1:2019-06","PN-EN 60684-2:2011","PN-EN 60454-2:2008","PN-EN 60851-5:2008","PN-EN 60851-5:2008/A1:2011","PN-EN 60851-5:2008/A2:2020-06"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products Napięcie przebicia w warunkach normalnych i w funkcji temperatury / Breakdown voltage under normal conditions and as a function of temperature\nZakres:\nw przedziale / in the range (20 -180) °C / (20 - 180) °C\ndo 25 kV / up to 25 kV PN-EN 60243-1:2013-12 | ASTM D149-20 | PN-EN 60464-2:2006 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60684-2:2011 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 Materialy i wyroby elektrotechniczne / Electrotechnical materials and products Napiecie przebicia w warunkach normalnych i w funkcji temperatury / Breakdown voltage under normal conditions and as a function of temperature\nZakres:\nw przedziale / in the range (20 -180) °C / (20 - 180) °C\ndo 25 kV / up to 25 kV PN-EN 60243-1:2013-12 | ASTM D149-20 | PN-EN 60464-2:2006 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60684-2:2011 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06","categories":["materials"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Breakdown voltage under normal conditions and as a function of temperature / Breakdown voltage under normal conditions and as a function of temperature","parameters_en":[{"name":"in the range","range":"(20 -180) °C / (20 - 180) °C"},{"name":"up to 25 kV"}],"search_en":"Electrotechnical materials and products Breakdown voltage under normal conditions and as a function of temperature / Breakdown voltage under normal conditions and as a function of temperature Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group in the range up to 25 kV Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60243-1:2013-12 | ASTM D149-20 | PN-EN 60464-2:2006 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60684-2:2011 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06","test_object_en":"Electrotechnical materials and products","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料与制品 / Electrotechnical materials and products 电工材料检测实验室；电工材料与制品研究组 PN-EN 60243-1:2013-12 | ASTM D149-20 | PN-EN 60464-2:2006 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60684-2:2011 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06","test_object_zh":"电工材料与制品 / Electrotechnical materials and products"},{"_id":"6a7d7594441eff5f15648786","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products","methodology":"Rezystancja w warunkach normalnych i w funkcji temperatury / Resistance under normal conditions and as a function of temperature","parameters":[{"name":"w przedziale / in the range of","range":"(20 - 180) °C"},{"name":"Zakres: / Range:","range":"(0,0001 - 1015) Ω"}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystancja w warunkach normalnych i w funkcji temperatury / Resistance under normal conditions and as a function of temperature\nZakres:\nw przedziale / in the range of (20 - 180) °C\nZakres: / Range: (0,0001 - 1015) Ω","reference":"PN-EN 62631-3-1:2023-10 | PN-EN IEC 62631-3-2:2024-07 | ASTM D257-14 (2021) e1 | PN-EN 62631-3-3:2016-08 | PN EN 60464-2:2006, p. 6.5.1 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60684-2:2011 p. 21, p. 22 i p. 23 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 62631-1:2011 | PN-EN 50395:2007, p. 5 | PN-EN 50395:2007/A1:2011","norm_bases":["PN-EN 62631-3-1:2023-10","PN-EN IEC 62631-3-2:2024-07","ASTM D257-14 (2021) e1","PN-EN 62631-3-3:2016-08","PN EN 60464-2:2006, p. 6.5.1","PN-EN 60464-2:2006/A1:2008","PN EN IEC 60455-2: 2024-04","PN-EN 60684-2:2011 p. 21, p. 22 i p. 23","PN-EN 60674-2:2017-04","PN-EN 60674-2:2017-04/A1:2019-06","PN-EN 60454-2:2008","PN-EN 60851-5:2008","PN-EN 60851-5:2008/A1:2011","PN-EN 60851-5:2008/A2:2020-06","PN-EN 62631-1:2011","PN-EN 50395:2007, p. 5","PN-EN 50395:2007/A1:2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby elektrotechniczne / Electrotechnical materials and products Rezystancja w warunkach normalnych i w funkcji temperatury / Resistance under normal conditions and as a function of temperature\nZakres:\nw przedziale / in the range of (20 - 180) °C\nZakres: / Range: (0,0001 - 1015) Ω PN-EN 62631-3-1:2023-10 | PN-EN IEC 62631-3-2:2024-07 | ASTM D257-14 (2021) e1 | PN-EN 62631-3-3:2016-08 | PN EN 60464-2:2006, p. 6.5.1 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60684-2:2011 p. 21, p. 22 i p. 23 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 62631-1:2011 | PN-EN 50395:2007, p. 5 | PN-EN 50395:2007/A1:2011 Materialy i wyroby elektrotechniczne / Electrotechnical materials and products Rezystancja w warunkach normalnych i w funkcji temperatury / Resistance under normal conditions and as a function of temperature\nZakres:\nw przedziale / in the range of (20 - 180) °C\nZakres: / Range: (0,0001 - 1015) Ω PN-EN 62631-3-1:2023-10 | PN-EN IEC 62631-3-2:2024-07 | ASTM D257-14 (2021) e1 | PN-EN 62631-3-3:2016-08 | PN EN 60464-2:2006, p. 6.5.1 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60684-2:2011 p. 21, p. 22 i p. 23 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 62631-1:2011 | PN-EN 50395:2007, p. 5 | PN-EN 50395:2007/A1:2011","categories":["materials"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Resistance under normal conditions and as a function of temperature","parameters_en":[{"name":"in the range of","range":"(20 - 180) °C"},{"name":"Range:","range":"(0,0001 - 1015) Ω"}],"search_en":"Electrotechnical materials and products Resistance under normal conditions and as a function of temperature Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group in the range of Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 62631-3-1:2023-10 | PN-EN IEC 62631-3-2:2024-07 | ASTM D257-14 (2021) e1 | PN-EN 62631-3-3:2016-08 | PN EN 60464-2:2006, p. 6.5.1 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60684-2:2011 p. 21, p. 22 i p. 23 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 62631-1:2011 | PN-EN 50395:2007, p. 5 | PN-EN 50395:2007/A1:2011","test_object_en":"Electrotechnical materials and products","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","parameters_zh":[{"name":"w przedziale / in the range of","range":"(20 - 180) °C"},{"name":"范围：","range":"(0,0001 - 1015) Ω"}],"search_zh":"电工材料与制品 / Electrotechnical materials and products 电工材料检测实验室；电工材料与制品研究组 范围： PN-EN 62631-3-1:2023-10 | PN-EN IEC 62631-3-2:2024-07 | ASTM D257-14 (2021) e1 | PN-EN 62631-3-3:2016-08 | PN EN 60464-2:2006, p. 6.5.1 | PN-EN 60464-2:2006/A1:2008 | PN EN IEC 60455-2: 2024-04 | PN-EN 60684-2:2011 p. 21, p. 22 i p. 23 | PN-EN 60674-2:2017-04 | PN-EN 60674-2:2017-04/A1:2019-06 | PN-EN 60454-2:2008 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 62631-1:2011 | PN-EN 50395:2007, p. 5 | PN-EN 50395:2007/A1:2011","test_object_zh":"电工材料与制品 / Electrotechnical materials and products"},{"_id":"6a7d7594441eff5f15648787","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, materiały, podzespoły, tworzywa sztuczne i pokrycia ochronne / Electrotechnical products, materials, components, plastics and protective coatings","methodology":"Odporność na nasłonecznienie / Sunlight resistance","parameters":[{"name":"Temp.: / temp.:","range":"+40 C lub 55 C / +40 C or 55 C"}],"technique":"Próba Sa / Test Sa","techniques":["Próba Sa / Test Sa"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na nasłonecznienie / Sunlight resistance\nTemp.: / temp.: +40 C lub 55 C / +40 C or 55 C\nPróba Sa / Test Sa","reference":"PN-EN 60068-2-5:2011 | PN-EN ISO 4892-2:2013-06","norm_bases":["PN-EN 60068-2-5:2011","PN-EN ISO 4892-2:2013-06"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby elektrotechniczne, materiały, podzespoły, tworzywa sztuczne i pokrycia ochronne / Electrotechnical products, materials, components, plastics and protective coatings Odporność na nasłonecznienie / Sunlight resistance\nTemp.: / temp.: +40 C lub 55 C / +40 C or 55 C\nPróba Sa / Test Sa PN-EN 60068-2-5:2011 | PN-EN ISO 4892-2:2013-06 Wyroby elektrotechniczne, materialy, podzespoly, tworzywa sztuczne i pokrycia ochronne / Electrotechnical products, materials, components, plastics and protective coatings Odpornosc na naslonecznienie / Sunlight resistance\nTemp.: / temp.: +40 C lub 55 C / +40 C or 55 C\nProba Sa / Test Sa PN-EN 60068-2-5:2011 | PN-EN ISO 4892-2:2013-06","categories":["materials"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Sunlight resistance","parameters_en":[{"name":"Temp.: / temp.:","range":"+40 C lub 55 C / +40 C or 55 C"}],"search_en":"Electrotechnical products, materials, components, plastics and protective coatings Sunlight resistance Test Sa Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Temp.: / temp.: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60068-2-5:2011 | PN-EN ISO 4892-2:2013-06","technique_en":"Test Sa","test_object_en":"Electrotechnical products, materials, components, plastics and protective coatings","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料检测实验室；电工材料与制品研究组 PN-EN 60068-2-5:2011 | PN-EN ISO 4892-2:2013-06"},{"_id":"6a7d7594441eff5f15648788","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, materiały, podzespoły, tworzywa sztuczne i pokrycia ochronne / Electrotechnical products, materials, components, plastics and protective coatings","methodology":"Odporność na działanie środowiska: Testy klimatyczne, odporność na zmiany temperatury / Environmental testing: Climate tests, change of temperature","parameters":[{"name":"Zakres temperatury: / Temperature range:","range":"(-65 - +90) C"},{"name":"Zakres wilgotności względnej powietrza / Relative humidity range:","range":"(10 - 98)%"}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na działanie środowiska: Testy klimatyczne, odporność na zmiany temperatury / Environmental testing: Climate tests, change of temperature\nZakres:\nZakres temperatury: / Temperature range: (-65 - +90) C\nZakres wilgotności względnej powietrza / Relative humidity range: (10 - 98)%","reference":"PN-EN 60068-2-38:2010 | PN-EN 60068-2-38:2010/Ap1:2011 | PN-EN 60068-2-30:2008 | PN-EN 60068-2-2:2009 | PN-EN 60068-2-14:2009/Ap1:2016-07E | PN-EN 60068-2-14:2009 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-78:2013-11","norm_bases":["PN-EN 60068-2-38:2010","PN-EN 60068-2-38:2010/Ap1:2011","PN-EN 60068-2-30:2008","PN-EN 60068-2-2:2009","PN-EN 60068-2-14:2009/Ap1:2016-07E","PN-EN 60068-2-14:2009","PN-EN 60068-2-1:2009","PN-EN 60068-2-78:2013-11"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby elektrotechniczne, materiały, podzespoły, tworzywa sztuczne i pokrycia ochronne / Electrotechnical products, materials, components, plastics and protective coatings Odporność na działanie środowiska: Testy klimatyczne, odporność na zmiany temperatury / Environmental testing: Climate tests, change of temperature\nZakres:\nZakres temperatury: / Temperature range: (-65 - +90) C\nZakres wilgotności względnej powietrza / Relative humidity range: (10 - 98)% PN-EN 60068-2-38:2010 | PN-EN 60068-2-38:2010/Ap1:2011 | PN-EN 60068-2-30:2008 | PN-EN 60068-2-2:2009 | PN-EN 60068-2-14:2009/Ap1:2016-07E | PN-EN 60068-2-14:2009 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-78:2013-11 Wyroby elektrotechniczne, materialy, podzespoly, tworzywa sztuczne i pokrycia ochronne / Electrotechnical products, materials, components, plastics and protective coatings Odpornosc na dzialanie srodowiska: Testy klimatyczne, odpornosc na zmiany temperatury / Environmental testing: Climate tests, change of temperature\nZakres:\nZakres temperatury: / Temperature range: (-65 - +90) C\nZakres wilgotnosci wzglednej powietrza / Relative humidity range: (10 - 98)% PN-EN 60068-2-38:2010 | PN-EN 60068-2-38:2010/Ap1:2011 | PN-EN 60068-2-30:2008 | PN-EN 60068-2-2:2009 | PN-EN 60068-2-14:2009/Ap1:2016-07E | PN-EN 60068-2-14:2009 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-78:2013-11","categories":["materials","environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Environmental testing: Climate tests, change of temperature","parameters_en":[{"name":"Temperature range:","range":"(-65 - +90) C"},{"name":"Relative air humidity range:","range":"(10 - 98)%"}],"search_en":"Electrotechnical products, materials, components, plastics and protective coatings Environmental testing: Climate tests, change of temperature Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Temperature range: Relative air humidity range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60068-2-38:2010 | PN-EN 60068-2-38:2010/Ap1:2011 | PN-EN 60068-2-30:2008 | PN-EN 60068-2-2:2009 | PN-EN 60068-2-14:2009/Ap1:2016-07E | PN-EN 60068-2-14:2009 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-78:2013-11","test_object_en":"Electrotechnical products, materials, components, plastics and protective coatings","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料检测实验室；电工材料与制品研究组 PN-EN 60068-2-38:2010 | PN-EN 60068-2-38:2010/Ap1:2011 | PN-EN 60068-2-30:2008 | PN-EN 60068-2-2:2009 | PN-EN 60068-2-14:2009/Ap1:2016-07E | PN-EN 60068-2-14:2009 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-78:2013-11"},{"_id":"6a7d7594441eff5f15648789","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały elektroizolacyjne stałe / Solid electrotechnical insulating materials","methodology":"Rezystywność skrośna, powierzchniowa i rezystancja izolacji / Volume, surface, and insulation resistivity","parameters":[{"name":"w temperaturze 23 C i w zakresie temperatur: / at 23 C and in the temperature range:","range":"(–50 - +90) C,"},{"name":"Zakres pomiarowy: rezystancji – / Range: resistance –","range":"(10 - 1017) ,"},{"name":"rezystywności – / resistivity –","range":"(10 - 1019) ·cm"}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystywność skrośna, powierzchniowa i rezystancja izolacji / Volume, surface, and insulation resistivity\nZakres:\nw temperaturze 23 C i w zakresie temperatur: / at 23 C and in the temperature range: (–50 - +90) C,\nZakres pomiarowy: rezystancji – / Range: resistance – (10 - 1017) ,\nrezystywności – / resistivity – (10 - 1019) ·cm","reference":"PN-88/E-04405 | IEC 60093:1980 | IEC 60167:1964 | ASTM D 257-99 | PN-EN 50395:2007 , p. 8 | PN-83/E-04160/73","norm_bases":["PN-88/E-04405","IEC 60093:1980","IEC 60167:1964","ASTM D 257-99","PN-EN 50395:2007 , p. 8","PN-83/E-04160/73"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały elektroizolacyjne stałe / Solid electrotechnical insulating materials Rezystywność skrośna, powierzchniowa i rezystancja izolacji / Volume, surface, and insulation resistivity\nZakres:\nw temperaturze 23 C i w zakresie temperatur: / at 23 C and in the temperature range: (–50 - +90) C,\nZakres pomiarowy: rezystancji – / Range: resistance – (10 - 1017) ,\nrezystywności – / resistivity – (10 - 1019) ·cm PN-88/E-04405 | IEC 60093:1980 | IEC 60167:1964 | ASTM D 257-99 | PN-EN 50395:2007 , p. 8 | PN-83/E-04160/73 Materialy elektroizolacyjne stale / Solid electrotechnical insulating materials Rezystywnosc skrosna, powierzchniowa i rezystancja izolacji / Volume, surface, and insulation resistivity\nZakres:\nw temperaturze 23 C i w zakresie temperatur: / at 23 C and in the temperature range: (–50 - +90) C,\nZakres pomiarowy: rezystancji – / Range: resistance – (10 - 1017) ,\nrezystywnosci – / resistivity – (10 - 1019) ·cm PN-88/E-04405 | IEC 60093:1980 | IEC 60167:1964 | ASTM D 257-99 | PN-EN 50395:2007 , p. 8 | PN-83/E-04160/73","categories":["materials","construction"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Volume, surface, and insulation resistivity","parameters_en":[{"name":"at 23 C and in the temperature range:","range":"(–50 - +90) C,"},{"name":"Measuring range: resistance –","range":"(10 - 1017) ,"},{"name":"resistivity –","range":"(10 - 1019) ·cm"}],"search_en":"Solid electrotechnical insulating materials Volume, surface, and insulation resistivity Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group at 23 C and in the temperature range: Measuring range: resistance – resistivity – Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-88/E-04405 | IEC 60093:1980 | IEC 60167:1964 | ASTM D 257-99 | PN-EN 50395:2007 , p. 8 | PN-83/E-04160/73","test_object_en":"Solid electrotechnical insulating materials","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料检测实验室；电工材料与制品研究组 PN-88/E-04405 | IEC 60093:1980 | IEC 60167:1964 | ASTM D 257-99 | PN-EN 50395:2007 , p. 8 | PN-83/E-04160/73"},{"_id":"6a7d7594441eff5f1564878a","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały elektrotechniczne, podzespoły i gotowe urządzenia (materiały izolacyjne i części izolacyjne wyrobów) / Electrotechnical materials, components and devices (insulating materials and insulating parts of products)","methodology":"Wytrzymałość elektryczna wykonywana napięciem przemiennym / Electric strength of insulating materials: Tests at power frequencies","parameters":[{"name":"Zakres: / Range:","range":"50 Hz ; 125 kV / 50 Hz; 125 kV"},{"name":"i stałym / And direct voltage","range":"do 30 kV / up to 30 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna wykonywana napięciem przemiennym / Electric strength of insulating materials: Tests at power frequencies\nZakres:\nZakres: / Range: 50 Hz ; 125 kV / 50 Hz; 125 kV\ni stałym / And direct voltage do 30 kV / up to 30 kV","reference":"PN-EN 60243-2:2014-07 | PN-K-92001:1997, p. 2.7 i p. 3.8 | PN-EN 60243-1:2013-12","norm_bases":["PN-EN 60243-2:2014-07","PN-K-92001:1997, p. 2.7 i p. 3.8","PN-EN 60243-1:2013-12"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały elektrotechniczne, podzespoły i gotowe urządzenia (materiały izolacyjne i części izolacyjne wyrobów) / Electrotechnical materials, components and devices (insulating materials and insulating parts of products) Wytrzymałość elektryczna wykonywana napięciem przemiennym / Electric strength of insulating materials: Tests at power frequencies\nZakres:\nZakres: / Range: 50 Hz ; 125 kV / 50 Hz; 125 kV\ni stałym / And direct voltage do 30 kV / up to 30 kV PN-EN 60243-2:2014-07 | PN-K-92001:1997, p. 2.7 i p. 3.8 | PN-EN 60243-1:2013-12 Materialy elektrotechniczne, podzespoly i gotowe urzadzenia (materialy izolacyjne i czesci izolacyjne wyrobow) / Electrotechnical materials, components and devices (insulating materials and insulating parts of products) Wytrzymalosc elektryczna wykonywana napieciem przemiennym / Electric strength of insulating materials: Tests at power frequencies\nZakres:\nZakres: / Range: 50 Hz ; 125 kV / 50 Hz; 125 kV\ni stalym / And direct voltage do 30 kV / up to 30 kV PN-EN 60243-2:2014-07 | PN-K-92001:1997, p. 2.7 i p. 3.8 | PN-EN 60243-1:2013-12","categories":["materials","construction"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Electric strength of insulating materials: Tests at power frequencies","parameters_en":[{"name":"Range:","range":"50 Hz ; 125 kV / 50 Hz; 125 kV"},{"name":"And direct voltage","range":"do 30 kV / up to 30 kV"}],"search_en":"Electrotechnical materials, components and devices (insulating materials and insulating parts of products) Electric strength of insulating materials: Tests at power frequencies Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Range: And direct voltage Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60243-2:2014-07 | PN-K-92001:1997, p. 2.7 i p. 3.8 | PN-EN 60243-1:2013-12","test_object_en":"Electrotechnical materials, components and devices (insulating materials and insulating parts of products)","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","parameters_zh":[{"name":"范围：","range":"50 Hz ; 125 kV / 50 Hz; 125 kV"},{"name":"i stałym / And direct voltage","range":"do 30 kV / up to 30 kV"}],"search_zh":"电工材料检测实验室；电工材料与制品研究组 范围： PN-EN 60243-2:2014-07 | PN-K-92001:1997, p. 2.7 i p. 3.8 | PN-EN 60243-1:2013-12"},{"_id":"6a7d7594441eff5f1564878b","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV","methodology":"Wytrzymałość na skręcanie / Torsion strength","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na skręcanie / Torsion strength","reference":"PN-EN 60832-1: 2010, p. 5.5.2, i p. 5.5.6","norm_bases":["PN-EN 60832-1: 2010, p. 5.5.2, i p. 5.5.6"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Wytrzymałość na skręcanie / Torsion strength PN-EN 60832-1: 2010, p. 5.5.2, i p. 5.5.6 Drazki izolacyjne i uniwersalne elementy robocze do prac pod napieciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Wytrzymalosc na skrecanie / Torsion strength PN-EN 60832-1: 2010, p. 5.5.2, i p. 5.5.6","categories":["construction"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Torsion strength","search_en":"Insulating sticks and attachable devices under voltage up to 150 kV Torsion strength Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60832-1: 2010, p. 5.5.2, i p. 5.5.6","test_object_en":"Insulating sticks and attachable devices under voltage up to 150 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN 60832-1: 2010, p. 5.5.2, i p. 5.5.6","test_object_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV"},{"_id":"6a7d7594441eff5f1564878c","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV","methodology":"Wytrzymałość na rozciąganie / Tension strength","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na rozciąganie / Tension strength","reference":"PN-EN 60832-1: 2010, p. 5.5.3","norm_bases":["PN-EN 60832-1: 2010, p. 5.5.3"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Wytrzymałość na rozciąganie / Tension strength PN-EN 60832-1: 2010, p. 5.5.3 Drazki izolacyjne i uniwersalne elementy robocze do prac pod napieciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Wytrzymalosc na rozciaganie / Tension strength PN-EN 60832-1: 2010, p. 5.5.3","categories":["construction"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Tension strength","search_en":"Insulating sticks and attachable devices under voltage up to 150 kV Tension strength Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60832-1: 2010, p. 5.5.3","test_object_en":"Insulating sticks and attachable devices under voltage up to 150 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN 60832-1: 2010, p. 5.5.3","test_object_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV"},{"_id":"6a7d7594441eff5f1564878d","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV","methodology":"Wytrzymałość na zginanie / Bending strength","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na zginanie / Bending strength","reference":"PN-EN 60832-1: 2010, p. 5.5.5","norm_bases":["PN-EN 60832-1: 2010, p. 5.5.5"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Wytrzymałość na zginanie / Bending strength PN-EN 60832-1: 2010, p. 5.5.5 Drazki izolacyjne i uniwersalne elementy robocze do prac pod napieciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Wytrzymalosc na zginanie / Bending strength PN-EN 60832-1: 2010, p. 5.5.5","categories":["construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Bending strength","search_en":"Insulating sticks and attachable devices under voltage up to 150 kV Bending strength Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60832-1: 2010, p. 5.5.5","test_object_en":"Insulating sticks and attachable devices under voltage up to 150 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN 60832-1: 2010, p. 5.5.5","test_object_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV"},{"_id":"6a7d7594441eff5f1564878e","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV","methodology":"Własności elektryczne po kondycjonowaniu w wodzie / Electrical test after water conditioning","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Własności elektryczne po kondycjonowaniu w wodzie / Electrical test after water conditioning","reference":"PN-EN 60832-1: 2010, p. 5.7.1","norm_bases":["PN-EN 60832-1: 2010, p. 5.7.1"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Własności elektryczne po kondycjonowaniu w wodzie / Electrical test after water conditioning PN-EN 60832-1: 2010, p. 5.7.1 Drazki izolacyjne i uniwersalne elementy robocze do prac pod napieciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Wlasnosci elektryczne po kondycjonowaniu w wodzie / Electrical test after water conditioning PN-EN 60832-1: 2010, p. 5.7.1","categories":["water","construction"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Electrical test after water conditioning","search_en":"Insulating sticks and attachable devices under voltage up to 150 kV Electrical test after water conditioning Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60832-1: 2010, p. 5.7.1","test_object_en":"Insulating sticks and attachable devices under voltage up to 150 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN 60832-1: 2010, p. 5.7.1","test_object_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV"},{"_id":"6a7d7594441eff5f1564878f","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV","methodology":"Odporność na rozpuszczalniki (tylko dla drążka pomiarowego) / Resistance solvent (only for measuring stick)","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na rozpuszczalniki (tylko dla drążka pomiarowego) / Resistance solvent (only for measuring stick)","reference":"PN-EN 60832-1: 2010, p. 5.8.8.1","norm_bases":["PN-EN 60832-1: 2010, p. 5.8.8.1"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Odporność na rozpuszczalniki (tylko dla drążka pomiarowego) / Resistance solvent (only for measuring stick) PN-EN 60832-1: 2010, p. 5.8.8.1 Drazki izolacyjne i uniwersalne elementy robocze do prac pod napieciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Odpornosc na rozpuszczalniki (tylko dla drazka pomiarowego) / Resistance solvent (only for measuring stick) PN-EN 60832-1: 2010, p. 5.8.8.1","categories":["construction"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Resistance solvent (only for measuring stick)","search_en":"Insulating sticks and attachable devices under voltage up to 150 kV Resistance solvent (only for measuring stick) Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60832-1: 2010, p. 5.8.8.1","test_object_en":"Insulating sticks and attachable devices under voltage up to 150 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN 60832-1: 2010, p. 5.8.8.1","test_object_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV"},{"_id":"6a7d7594441eff5f15648790","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV","methodology":"Odporność na ścieranie (tylko dla drążka pomiarowego) / Resistance to abrasion (only for measuring stick)","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na ścieranie (tylko dla drążka pomiarowego) / Resistance to abrasion (only for measuring stick)","reference":"PN-EN 60832-1: 2010, p. 5.8.8.2","norm_bases":["PN-EN 60832-1: 2010, p. 5.8.8.2"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Odporność na ścieranie (tylko dla drążka pomiarowego) / Resistance to abrasion (only for measuring stick) PN-EN 60832-1: 2010, p. 5.8.8.2 Drazki izolacyjne i uniwersalne elementy robocze do prac pod napieciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Odpornosc na scieranie (tylko dla drazka pomiarowego) / Resistance to abrasion (only for measuring stick) PN-EN 60832-1: 2010, p. 5.8.8.2","categories":["construction"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Resistance to abrasion (only for measuring stick)","search_en":"Insulating sticks and attachable devices under voltage up to 150 kV Resistance to abrasion (only for measuring stick) Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60832-1: 2010, p. 5.8.8.2","test_object_en":"Insulating sticks and attachable devices under voltage up to 150 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN 60832-1: 2010, p. 5.8.8.2","test_object_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV"},{"_id":"6a7d7594441eff5f15648791","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV","methodology":"Wytrzymałość elektryczna po odporności na ścieranie / Electrical test after abrasion test","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna po odporności na ścieranie / Electrical test after abrasion test","reference":"PN-EN 60832-1: 2010, p. 5.8.8.3","norm_bases":["PN-EN 60832-1: 2010, p. 5.8.8.3"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drążki izolacyjne i uniwersalne elementy robocze do prac pod napięciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Wytrzymałość elektryczna po odporności na ścieranie / Electrical test after abrasion test PN-EN 60832-1: 2010, p. 5.8.8.3 Drazki izolacyjne i uniwersalne elementy robocze do prac pod napieciem do 150 kV / Insulating sticks and attachable devices under voltage up to 150 kV Wytrzymalosc elektryczna po odpornosci na scieranie / Electrical test after abrasion test PN-EN 60832-1: 2010, p. 5.8.8.3","categories":["construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Electric strength test after abrasion test","search_en":"Insulating sticks and attachable devices under voltage up to 150 kV Electric strength test after abrasion test Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60832-1: 2010, p. 5.8.8.3","test_object_en":"Insulating sticks and attachable devices under voltage up to 150 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN 60832-1: 2010, p. 5.8.8.3","test_object_zh":"150 kV 及以下带电作业用绝缘操作杆与通用作业头 / Insulating sticks and attachable devices under voltage up to 150 kV"},{"_id":"6a7d7594441eff5f15648792","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Kleszcze i chwytaki izolacyjne / Insulating tongs and grippers","methodology":"Wymiary liniowe / Linear dimensions","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wymiary liniowe / Linear dimensions","reference":"PB-5/LB/IEL/OTiME p. 9.3, wyd. 5 z 02.03.2011","norm_bases":["PB-5/LB/IEL/OTiME p. 9.3, wyd. 5 z 02.03.2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kleszcze i chwytaki izolacyjne / Insulating tongs and grippers Wymiary liniowe / Linear dimensions PB-5/LB/IEL/OTiME p. 9.3, wyd. 5 z 02.03.2011 Kleszcze i chwytaki izolacyjne / Insulating tongs and grippers Wymiary liniowe / Linear dimensions PB-5/LB/IEL/OTiME p. 9.3, wyd. 5 z 02.03.2011","categories":["construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Linear dimensions","search_en":"Insulating tongs and grippers Linear dimensions Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PB-5/LB/IEL/OTiME p. 9.3, wyd. 5 z 02.03.2011","test_object_en":"Insulating tongs and grippers","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料检测实验室；电工材料与制品研究组 PB-5/LB/IEL/OTiME p. 9.3, wyd. 5 z 02.03.2011"},{"_id":"6a7d7594441eff5f15648793","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Kleszcze i chwytaki izolacyjne / Insulating tongs and grippers","methodology":"Wytrzymałość elektryczna kleszczy / Electrical strength of tongs","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna kleszczy / Electrical strength of tongs","reference":"PB-5/LB/IEL/OTiME p. 9.9, wyd. 5 z 02.03.2011","norm_bases":["PB-5/LB/IEL/OTiME p. 9.9, wyd. 5 z 02.03.2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kleszcze i chwytaki izolacyjne / Insulating tongs and grippers Wytrzymałość elektryczna kleszczy / Electrical strength of tongs PB-5/LB/IEL/OTiME p. 9.9, wyd. 5 z 02.03.2011 Kleszcze i chwytaki izolacyjne / Insulating tongs and grippers Wytrzymalosc elektryczna kleszczy / Electrical strength of tongs PB-5/LB/IEL/OTiME p. 9.9, wyd. 5 z 02.03.2011","categories":["construction"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Electrical strength of tongs","search_en":"Insulating tongs and grippers Electrical strength of tongs Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PB-5/LB/IEL/OTiME p. 9.9, wyd. 5 z 02.03.2011","test_object_en":"Insulating tongs and grippers","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料检测实验室；电工材料与制品研究组 PB-5/LB/IEL/OTiME p. 9.9, wyd. 5 z 02.03.2011"},{"_id":"6a7d7594441eff5f15648794","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Chodniki elektroizolacyjne / Electrical insulating matting","methodology":"Próby elektryczne / Electrical tests","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Próby elektryczne / Electrical tests","reference":"PN-EN 61111:2009 p. 5.6.","norm_bases":["PN-EN 61111:2009 p. 5.6."],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Chodniki elektroizolacyjne / Electrical insulating matting Próby elektryczne / Electrical tests PN-EN 61111:2009 p. 5.6. Chodniki elektroizolacyjne / Electrical insulating matting Proby elektryczne / Electrical tests PN-EN 61111:2009 p. 5.6.","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Electrical tests","search_en":"Electrical insulating matting Electrical tests Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61111:2009 p. 5.6.","test_object_en":"Electrical insulating matting","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料检测实验室；电工材料与制品研究组 PN-EN 61111:2009 p. 5.6."},{"_id":"6a7d7594441eff5f15648795","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Rękawice elektroizolacyjne / Gloves of insulating material","methodology":"Próby elektryczne napięciem stałym i przemiennym / Live working","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Próby elektryczne napięciem stałym i przemiennym / Live working","reference":"PN-EN 60903:2006 p. 8.4","norm_bases":["PN-EN 60903:2006 p. 8.4"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rękawice elektroizolacyjne / Gloves of insulating material Próby elektryczne napięciem stałym i przemiennym / Live working PN-EN 60903:2006 p. 8.4 Rekawice elektroizolacyjne / Gloves of insulating material Proby elektryczne napieciem stalym i przemiennym / Live working PN-EN 60903:2006 p. 8.4","categories":["materials"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Electrical tests with direct and alternating voltage / Live working","search_en":"Gloves of insulating material Electrical tests with direct and alternating voltage / Live working Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60903:2006 p. 8.4","test_object_en":"Gloves of insulating material","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料检测实验室；电工材料与制品研究组 PN-EN 60903:2006 p. 8.4"},{"_id":"6a7d7594441eff5f15648796","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Kalosze i półbuty elektroizolacyjne / Insulating overboots and shoes","methodology":"Wytrzymałość elektryczna i prąd upływu / Electrical strength and leakage current","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna i prąd upływu / Electrical strength and leakage current","reference":"PB-13/LB/IEL/OTiME, wyd. 4 z 06.05.2008 | PN-EN 50321-1:2018-05","norm_bases":["PB-13/LB/IEL/OTiME, wyd. 4 z 06.05.2008","PN-EN 50321-1:2018-05"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kalosze i półbuty elektroizolacyjne / Insulating overboots and shoes Wytrzymałość elektryczna i prąd upływu / Electrical strength and leakage current PB-13/LB/IEL/OTiME, wyd. 4 z 06.05.2008 | PN-EN 50321-1:2018-05 Kalosze i polbuty elektroizolacyjne / Insulating overboots and shoes Wytrzymalosc elektryczna i prad uplywu / Electrical strength and leakage current PB-13/LB/IEL/OTiME, wyd. 4 z 06.05.2008 | PN-EN 50321-1:2018-05","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Electrical strength and leakage current","search_en":"Insulating overboots and shoes Electrical strength and leakage current Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PB-13/LB/IEL/OTiME, wyd. 4 z 06.05.2008 | PN-EN 50321-1:2018-05","test_object_en":"Insulating overboots and shoes","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"电工材料检测实验室；电工材料与制品研究组 PB-13/LB/IEL/OTiME, wyd. 4 z 06.05.2008 | PN-EN 50321-1:2018-05"},{"_id":"6a7d7594441eff5f15648797","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","methodology":"Napięcie progowe / Threshold voltage","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Napięcie progowe / Threshold voltage","reference":"PN-EN IEC 61243-1:2022-01","norm_bases":["PN-EN IEC 61243-1:2022-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Napięcie progowe / Threshold voltage PN-EN IEC 61243-1:2022-01 Wskazniki napiecia typu pojemnosciowego do stosowania przy napieciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Napiecie progowe / Threshold voltage PN-EN IEC 61243-1:2022-01","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Threshold voltage / Threshold voltage","search_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Threshold voltage / Threshold voltage Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 61243-1:2022-01","test_object_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN IEC 61243-1:2022-01","test_object_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV"},{"_id":"6a7d7594441eff5f15648798","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","methodology":"Czas pracy / Time rating","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Czas pracy / Time rating","reference":"PN-EN IEC 61243-1:2022-01","norm_bases":["PN-EN IEC 61243-1:2022-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Czas pracy / Time rating PN-EN IEC 61243-1:2022-01 Wskazniki napiecia typu pojemnosciowego do stosowania przy napieciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Czas pracy / Time rating PN-EN IEC 61243-1:2022-01","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Time rating","search_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Time rating Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 61243-1:2022-01","test_object_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN IEC 61243-1:2022-01","test_object_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV"},{"_id":"6a7d7594441eff5f15648799","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","methodology":"Zabezpieczenie przed zmostkowaniem wskaźników napięcia typu wnętrzowego i napowietrznego / Protection against bridging for indoor type/outdoor type voltage detector","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Zabezpieczenie przed zmostkowaniem wskaźników napięcia typu wnętrzowego i napowietrznego / Protection against bridging for indoor type/outdoor type voltage detector","reference":"PN-EN IEC 61243-1:2022-01","norm_bases":["PN-EN IEC 61243-1:2022-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Zabezpieczenie przed zmostkowaniem wskaźników napięcia typu wnętrzowego i napowietrznego / Protection against bridging for indoor type/outdoor type voltage detector PN-EN IEC 61243-1:2022-01 Wskazniki napiecia typu pojemnosciowego do stosowania przy napieciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Zabezpieczenie przed zmostkowaniem wskaznikow napiecia typu wnetrzowego i napowietrznego / Protection against bridging for indoor type/outdoor type voltage detector PN-EN IEC 61243-1:2022-01","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Protection against bridging for indoor type/outdoor type voltage detector","search_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Protection against bridging for indoor type/outdoor type voltage detector Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 61243-1:2022-01","test_object_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN IEC 61243-1:2022-01","test_object_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV"},{"_id":"6a7d7594441eff5f1564879a","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","methodology":"Odporność na iskrzenie / Spark resistance","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na iskrzenie / Spark resistance","reference":"PN-EN IEC 61243-1:2022-01","norm_bases":["PN-EN IEC 61243-1:2022-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Odporność na iskrzenie / Spark resistance PN-EN IEC 61243-1:2022-01 Wskazniki napiecia typu pojemnosciowego do stosowania przy napieciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Odpornosc na iskrzenie / Spark resistance PN-EN IEC 61243-1:2022-01","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Spark resistance","search_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Spark resistance Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 61243-1:2022-01","test_object_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN IEC 61243-1:2022-01","test_object_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV"},{"_id":"6a7d7594441eff5f1564879b","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","methodology":"Odporność na upadek / Drop resistance","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na upadek / Drop resistance","reference":"PN-EN IEC 61243-1:2022-01","norm_bases":["PN-EN IEC 61243-1:2022-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Odporność na upadek / Drop resistance PN-EN IEC 61243-1:2022-01 Wskazniki napiecia typu pojemnosciowego do stosowania przy napieciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Odpornosc na upadek / Drop resistance PN-EN IEC 61243-1:2022-01","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Drop resistance","search_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Drop resistance Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 61243-1:2022-01","test_object_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN IEC 61243-1:2022-01","test_object_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV"},{"_id":"6a7d7594441eff5f1564879c","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","methodology":"Odporność na warunki klimatyczne / Climatic dependence","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na warunki klimatyczne / Climatic dependence","reference":"PN-EN IEC 61243-1:2022-01","norm_bases":["PN-EN IEC 61243-1:2022-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Odporność na warunki klimatyczne / Climatic dependence PN-EN IEC 61243-1:2022-01 Wskazniki napiecia typu pojemnosciowego do stosowania przy napieciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Odpornosc na warunki klimatyczne / Climatic dependence PN-EN IEC 61243-1:2022-01","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Climatic dependence","search_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Climatic dependence Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 61243-1:2022-01","test_object_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN IEC 61243-1:2022-01","test_object_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV"},{"_id":"6a7d7594441eff5f1564879d","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","methodology":"Trwałość oznakowania / Durability of markings","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Trwałość oznakowania / Durability of markings","reference":"PN-EN IEC 61243-1:2022-01","norm_bases":["PN-EN IEC 61243-1:2022-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Trwałość oznakowania / Durability of markings PN-EN IEC 61243-1:2022-01 Wskazniki napiecia typu pojemnosciowego do stosowania przy napieciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Trwalosc oznakowania / Durability of markings PN-EN IEC 61243-1:2022-01","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Durability of markings","search_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Durability of markings Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 61243-1:2022-01","test_object_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN IEC 61243-1:2022-01","test_object_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV"},{"_id":"6a7d7594441eff5f1564879e","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","methodology":"Badania wpływu czynników zakłócających na jednoznaczną sygnalizację / Clear Indication: influence of in-phase interference field, opposite interference field and interference voltage","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Badania wpływu czynników zakłócających na jednoznaczną sygnalizację / Clear Indication: influence of in-phase interference field, opposite interference field and interference voltage","reference":"PN-EN IEC 61243-1:2022-01","norm_bases":["PN-EN IEC 61243-1:2022-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół badania materiałów i wyrobów elektrotechnicznych; Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźniki napięcia typu pojemnościowego do stosowania przy napięciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Badania wpływu czynników zakłócających na jednoznaczną sygnalizację / Clear Indication: influence of in-phase interference field, opposite interference field and interference voltage PN-EN IEC 61243-1:2022-01 Wskazniki napiecia typu pojemnosciowego do stosowania przy napieciach przemiennych od 0,23 kV do 52 kV / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Badania wplywu czynnikow zaklocajacych na jednoznaczna sygnalizacje / Clear Indication: influence of in-phase interference field, opposite interference field and interference voltage PN-EN IEC 61243-1:2022-01","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group","methodology_en":"Testing of the influence of interfering factors on clear indication / Clear Indication: influence of in-phase interference field, opposite interference field and interference voltage","search_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV Testing of the influence of interfering factors on clear indication / Clear Indication: influence of in-phase interference field, opposite interference field and interference voltage Electrotechnical Materials Testing Laboratory; Electrotechnical Materials and Products Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 61243-1:2022-01","test_object_en":"Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV","lab_section_zh":"电工材料检测实验室；电工材料与制品研究组","search_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV 电工材料检测实验室；电工材料与制品研究组 PN-EN IEC 61243-1:2022-01","test_object_zh":"用于 0,23 kV 至 52 kV 交流电压的电容型验电器 / Voltage detectors - Capacitive type to be used for voltages exceeding 1 kV AC from 0,23 kV to 52 kV"},{"_id":"6a7d7594441eff5f1564879f","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials","methodology":"Gęstość i porowatość otwarta / Bulk density and open (apparent) porosity","parameters":[],"technique":"Metoda ważenia hydrostatycznego / Hydrostatic method of weighting","techniques":["Metoda ważenia hydrostatycznego / Hydrostatic method of weighting"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Gęstość i porowatość otwarta / Bulk density and open (apparent) porosity\nMetoda ważenia hydrostatycznego / Hydrostatic method of weighting","reference":"PN-EN 60672-2:2002 | PN-EN 60672-3:2002","norm_bases":["PN-EN 60672-2:2002","PN-EN 60672-3:2002"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials Gęstość i porowatość otwarta / Bulk density and open (apparent) porosity\nMetoda ważenia hydrostatycznego / Hydrostatic method of weighting PN-EN 60672-2:2002 | PN-EN 60672-3:2002 Materialy ceramiczne i szklane / Ceramic and glass insulating materials Gestosc i porowatosc otwarta / Bulk density and open (apparent) porosity\nMetoda wazenia hydrostatycznego / Hydrostatic method of weighting PN-EN 60672-2:2002 | PN-EN 60672-3:2002","categories":["materials"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Bulk density and open (apparent) porosity","search_en":"Ceramic and glass insulating materials Bulk density and open (apparent) porosity Hydrostatic method of weighting Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60672-2:2002 | PN-EN 60672-3:2002","technique_en":"Hydrostatic method of weighting","test_object_en":"Ceramic and glass insulating materials","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials 电工材料检测实验室；绝缘子研究组 PN-EN 60672-2:2002 | PN-EN 60672-3:2002","test_object_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials"},{"_id":"6a7d7594441eff5f156487a0","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials","methodology":"Wytrzymałość mechaniczna na zginanie / Flexural strength","parameters":[],"technique":"Próba zginania trójpunktowa / Triple point test","techniques":["Próba zginania trójpunktowa / Triple point test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość mechaniczna na zginanie / Flexural strength\nPróba zginania trójpunktowa / Triple point test","reference":"PN-EN 60672-1:2010 | PN-EN 60672-2:2002 pkt. 6 | PN-EN 60672-3:2002","norm_bases":["PN-EN 60672-1:2010","PN-EN 60672-2:2002 pkt. 6","PN-EN 60672-3:2002"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials Wytrzymałość mechaniczna na zginanie / Flexural strength\nPróba zginania trójpunktowa / Triple point test PN-EN 60672-1:2010 | PN-EN 60672-2:2002 pkt. 6 | PN-EN 60672-3:2002 Materialy ceramiczne i szklane / Ceramic and glass insulating materials Wytrzymalosc mechaniczna na zginanie / Flexural strength\nProba zginania trojpunktowa / Triple point test PN-EN 60672-1:2010 | PN-EN 60672-2:2002 pkt. 6 | PN-EN 60672-3:2002","categories":["materials"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Mechanical flexural strength","search_en":"Ceramic and glass insulating materials Mechanical flexural strength Triple point bending test Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60672-1:2010 | PN-EN 60672-2:2002 pkt. 6 | PN-EN 60672-3:2002","technique_en":"Triple point bending test","test_object_en":"Ceramic and glass insulating materials","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials 电工材料检测实验室；绝缘子研究组 PN-EN 60672-1:2010 | PN-EN 60672-2:2002 pkt. 6 | PN-EN 60672-3:2002","test_object_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials"},{"_id":"6a7d7594441eff5f156487a1","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials","methodology":"Odporność na pękanie / Resistance to cracking","parameters":[{"name":"Zakres: / Range to","range":"250 oC / 250 °C"}],"technique":"Próba odporności na nagłe zmiany temperatury / Resistance to thermal shock","techniques":["Próba odporności na nagłe zmiany temperatury / Resistance to thermal shock"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na pękanie / Resistance to cracking\nZakres: / Range to 250 oC / 250 °C\nPróba odporności na nagłe zmiany temperatury / Resistance to thermal shock","reference":"PN-EN 60672-2:2002 | PN-EN 60672-3:2002","norm_bases":["PN-EN 60672-2:2002","PN-EN 60672-3:2002"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials Odporność na pękanie / Resistance to cracking\nZakres: / Range to 250 oC / 250 °C\nPróba odporności na nagłe zmiany temperatury / Resistance to thermal shock PN-EN 60672-2:2002 | PN-EN 60672-3:2002 Materialy ceramiczne i szklane / Ceramic and glass insulating materials Odpornosc na pekanie / Resistance to cracking\nZakres: / Range to 250 oC / 250 °C\nProba odpornosci na nagle zmiany temperatury / Resistance to thermal shock PN-EN 60672-2:2002 | PN-EN 60672-3:2002","categories":["materials"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Resistance to cracking","parameters_en":[{"name":"Range to","range":"250 oC / 250 °C"}],"search_en":"Ceramic and glass insulating materials Resistance to cracking Resistance to thermal shock test Electrotechnical Materials Testing Laboratory; Insulator Research Group Range to Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60672-2:2002 | PN-EN 60672-3:2002","technique_en":"Resistance to thermal shock test","test_object_en":"Ceramic and glass insulating materials","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials 电工材料检测实验室；绝缘子研究组 PN-EN 60672-2:2002 | PN-EN 60672-3:2002","test_object_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials"},{"_id":"6a7d7594441eff5f156487a2","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials","methodology":"Wytrzymałość elektryczna / Electric strength","parameters":[{"name":"Zakres: / Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Pomiar napięcia przebicia 50 Hz / Measurements of the breakdown voltage","techniques":["Pomiar napięcia przebicia 50 Hz / Measurements of the breakdown voltage"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPomiar napięcia przebicia 50 Hz / Measurements of the breakdown voltage","reference":"PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12","norm_bases":["PN-EN 60672-2:2002","PN-EN 60672-3:2002","PN-EN 60243-1:2013-12"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials Wytrzymałość elektryczna / Electric strength\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPomiar napięcia przebicia 50 Hz / Measurements of the breakdown voltage PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12 Materialy ceramiczne i szklane / Ceramic and glass insulating materials Wytrzymalosc elektryczna / Electric strength\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPomiar napiecia przebicia 50 Hz / Measurements of the breakdown voltage PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12","categories":["materials"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength / Electric strength","parameters_en":[{"name":"Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Ceramic and glass insulating materials Electric strength / Electric strength Measurements of the breakdown voltage Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12","technique_en":"Measurements of the breakdown voltage","test_object_en":"Ceramic and glass insulating materials","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12","parameters_zh":[{"name":"范围：","range":"(5 - 125) kV / 5 – 125 kV"}],"test_object_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials"},{"_id":"6a7d7594441eff5f156487a3","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials","methodology":"Napięcie wytrzymywane / Withstand voltage,","parameters":[{"name":"Zakres: / Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Próba napięciem wytrzymywanym 50 Hz / Test by withstand voltage.","techniques":["Próba napięciem wytrzymywanym 50 Hz / Test by withstand voltage."],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Napięcie wytrzymywane / Withstand voltage,\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem wytrzymywanym 50 Hz / Test by withstand voltage.","reference":"PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12","norm_bases":["PN-EN 60672-2:2002","PN-EN 60672-3:2002","PN-EN 60243-1:2013-12"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials Napięcie wytrzymywane / Withstand voltage,\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem wytrzymywanym 50 Hz / Test by withstand voltage. PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12 Materialy ceramiczne i szklane / Ceramic and glass insulating materials Napiecie wytrzymywane / Withstand voltage,\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nProba napieciem wytrzymywanym 50 Hz / Test by withstand voltage. PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12","categories":["materials"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Withstand voltage / Withstand voltage,","parameters_en":[{"name":"Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Ceramic and glass insulating materials Withstand voltage / Withstand voltage, Test by withstand voltage. Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12","technique_en":"Test by withstand voltage.","test_object_en":"Ceramic and glass insulating materials","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60672-2:2002 | PN-EN 60672-3:2002 | PN-EN 60243-1:2013-12","parameters_zh":[{"name":"范围：","range":"(5 - 125) kV / 5 – 125 kV"}],"test_object_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials"},{"_id":"6a7d7594441eff5f156487a4","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials","methodology":"Rezystywność skrośna / Volume resistivity.","parameters":[{"name":"Zakres: / Range:","range":"(106 -1016) Ω·m / 106 – 1016 Ω·m"}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystywność skrośna / Volume resistivity.\nZakres: / Range: (106 -1016) Ω·m / 106 – 1016 Ω·m","reference":"PN-EN 60672-2:2002 | PN-EN 60672-3:2002","norm_bases":["PN-EN 60672-2:2002","PN-EN 60672-3:2002"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały ceramiczne i szklane / Ceramic and glass insulating materials Rezystywność skrośna / Volume resistivity.\nZakres: / Range: (106 -1016) Ω·m / 106 – 1016 Ω·m PN-EN 60672-2:2002 | PN-EN 60672-3:2002 Materialy ceramiczne i szklane / Ceramic and glass insulating materials Rezystywnosc skrosna / Volume resistivity.\nZakres: / Range: (106 -1016) Ω·m / 106 – 1016 Ω·m PN-EN 60672-2:2002 | PN-EN 60672-3:2002","categories":["materials"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Volume resistivity.","parameters_en":[{"name":"Range:","range":"(106 -1016) Ω·m / 106 – 1016 Ω·m"}],"search_en":"Ceramic and glass insulating materials Volume resistivity. Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60672-2:2002 | PN-EN 60672-3:2002","test_object_en":"Ceramic and glass insulating materials","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60672-2:2002 | PN-EN 60672-3:2002","parameters_zh":[{"name":"范围：","range":"(106 -1016) Ω·m / 106 – 1016 Ω·m"}],"test_object_zh":"陶瓷与玻璃材料 / Ceramic and glass insulating materials"},{"_id":"6a7d7594441eff5f156487a5","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Twardość / Hardness test","parameters":[{"name":"Zakres: / range:","range":"do 100 ShA / to 100ShA"}],"technique":"Próba twardości Shore’a / Shore A method","techniques":["Próba twardości Shore’a / Shore A method"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Twardość / Hardness test\nZakres: / range: do 100 ShA / to 100ShA\nPróba twardości Shore’a / Shore A method","reference":"PN-EN 62217:2013-06 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN ISO 868:2005","norm_bases":["PN-EN 62217:2013-06 pkt. 9.3.1.","PN-EN 61462:2009","PN-EN ISO 868:2005"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Twardość / Hardness test\nZakres: / range: do 100 ShA / to 100ShA\nPróba twardości Shore’a / Shore A method PN-EN 62217:2013-06 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN ISO 868:2005 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Twardosc / Hardness test\nZakres: / range: do 100 ShA / to 100ShA\nProba twardosci Shore’a / Shore A method PN-EN 62217:2013-06 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN ISO 868:2005","categories":["materials"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Hardness test","parameters_en":[{"name":"range:","range":"do 100 ShA / to 100ShA"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Hardness test Shore hardness test Shore A method Electrotechnical Materials Testing Laboratory; Insulator Research Group range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 62217:2013-06 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN ISO 868:2005","technique_en":"Shore hardness test Shore A method","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： / range: PN-EN 62217:2013-06 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN ISO 868:2005","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","parameters_zh":[{"name":"范围： / range:","range":"do 100 ShA / to 100ShA"}]},{"_id":"6a7d7594441eff5f156487a6","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Odporności na wyładowania pełzne i erozje / Tracking and erosion test – 1000 h salt fog test","parameters":[{"name":"Zakres Up / Range Up","range":"do 30 kV / to 30 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporności na wyładowania pełzne i erozje / Tracking and erosion test – 1000 h salt fog test\nZakres Up / Range Up do 30 kV / to 30 kV","reference":"PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010","norm_bases":["PN-EN 61109:2010","PN-EN 62217:2013-06","PN-EN 61462:2009","PN-EN 61952:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Odporności na wyładowania pełzne i erozje / Tracking and erosion test – 1000 h salt fog test\nZakres Up / Range Up do 30 kV / to 30 kV PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Odpornosci na wyladowania pelzne i erozje / Tracking and erosion test – 1000 h salt fog test\nZakres Up / Range Up do 30 kV / to 30 kV PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010","categories":["materials"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Tracking and erosion test – 1000 h salt fog test","parameters_en":[{"name":"Range Up","range":"do 30 kV / to 30 kV"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Tracking and erosion test – 1000 h salt fog test Electrotechnical Materials Testing Laboratory; Insulator Research Group Range Up Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487a7","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Nieciągłości / Porosity test (Dye penetration test)","parameters":[],"technique":"Próba penetracji barwnikiem / Dye penetration test","techniques":["Próba penetracji barwnikiem / Dye penetration test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Nieciągłości / Porosity test (Dye penetration test)\nPróba penetracji barwnikiem / Dye penetration test","reference":"PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010 | PN-EN ISO 3452-1:2021-12","norm_bases":["PN-EN 61109:2010","PN-EN 62217:2013-06","PN-EN 61462:2009","PN-EN 61952:2010","PN-EN ISO 3452-1:2021-12"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Nieciągłości / Porosity test (Dye penetration test)\nPróba penetracji barwnikiem / Dye penetration test PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010 | PN-EN ISO 3452-1:2021-12 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Nieciaglosci / Porosity test (Dye penetration test)\nProba penetracji barwnikiem / Dye penetration test PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010 | PN-EN ISO 3452-1:2021-12","categories":["materials"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Discontinuities / Porosity test (Dye penetration test)","search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Discontinuities / Porosity test (Dye penetration test) Dye penetration test / Dye penetration test Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010 | PN-EN ISO 3452-1:2021-12","technique_en":"Dye penetration test / Dye penetration test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 61952:2010 | PN-EN ISO 3452-1:2021-12","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487a8","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Nasiąkliwość/wnikanie wody / Water diffusion test","parameters":[],"technique":"Próba dyfuzji wody / Water diffusion test","techniques":["Próba dyfuzji wody / Water diffusion test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Nasiąkliwość/wnikanie wody / Water diffusion test\nPróba dyfuzji wody / Water diffusion test","reference":"PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010","norm_bases":["PN-EN 61109:2010","PN-EN 62217:2013-06","PN-EN 62231:2008","PN-EN 61462:2009","PN-EN 61952:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Nasiąkliwość/wnikanie wody / Water diffusion test\nPróba dyfuzji wody / Water diffusion test PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Nasiakliwosc/wnikanie wody / Water diffusion test\nProba dyfuzji wody / Water diffusion test PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010","categories":["materials","water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Water absorption/water penetration / Water diffusion test","search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Water absorption/water penetration / Water diffusion test Water diffusion test Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010","technique_en":"Water diffusion test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 PN-EN 61109:2010 | PN-EN 62217:2013-06 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487a9","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Narażenie termomechaniczne – wytrzymałość na rozciąganie / Thermal-mechanical pre-stress","parameters":[{"name":"Zakres: / tensile load:","range":"do 300 kN / to 300 kN"},{"name":"- wytrzymałość na zginanie Zakres: / bending load:","range":"do 20 kN / to 20 kN"}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Narażenie termomechaniczne – wytrzymałość na rozciąganie / Thermal-mechanical pre-stress\nZakres:\nZakres: / tensile load: do 300 kN / to 300 kN\n- wytrzymałość na zginanie Zakres: / bending load: do 20 kN / to 20 kN","reference":"PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010","norm_bases":["PN-EN 61109:2010","PN-EN 62231:2008","PN-EN 61462:2009","PN-EN 61952:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Narażenie termomechaniczne – wytrzymałość na rozciąganie / Thermal-mechanical pre-stress\nZakres:\nZakres: / tensile load: do 300 kN / to 300 kN\n- wytrzymałość na zginanie Zakres: / bending load: do 20 kN / to 20 kN PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Narazenie termomechaniczne – wytrzymalosc na rozciaganie / Thermal-mechanical pre-stress\nZakres:\nZakres: / tensile load: do 300 kN / to 300 kN\n- wytrzymalosc na zginanie Zakres: / bending load: do 20 kN / to 20 kN PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010","categories":["materials"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Thermal-mechanical pre-stressing – tensile strength / Thermal-mechanical pre-stress","parameters_en":[{"name":"tensile load:","range":"do 300 kN / to 300 kN"},{"name":"- bending load Range:","range":"do 20 kN / to 20 kN"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Thermal-mechanical pre-stressing – tensile strength / Thermal-mechanical pre-stress Electrotechnical Materials Testing Laboratory; Insulator Research Group tensile load: - bending load Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61462:2009 | PN-EN 61952:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487aa","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Narażenie przez zanurzenie w wodzie / Water immersion pre-stressing","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Narażenie przez zanurzenie w wodzie / Water immersion pre-stressing","reference":"PN-EN 62217:2013-06","norm_bases":["PN-EN 62217:2013-06"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Narażenie przez zanurzenie w wodzie / Water immersion pre-stressing PN-EN 62217:2013-06 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Narazenie przez zanurzenie w wodzie / Water immersion pre-stressing PN-EN 62217:2013-06","categories":["materials","water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Pre-stressing by water immersion / Water immersion pre-stressing","search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Pre-stressing by water immersion / Water immersion pre-stressing Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 62217:2013-06","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 PN-EN 62217:2013-06","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487ab","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Szczelność między powierzchniami granicznymi / Tightness between boundary surfaces test","parameters":[],"technique":"Próba penetracji barwnikiem / Dye penetration test","techniques":["Próba penetracji barwnikiem / Dye penetration test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Szczelność między powierzchniami granicznymi / Tightness between boundary surfaces test\nPróba penetracji barwnikiem / Dye penetration test","reference":"PN-EN 61109:2010 | PN-EN ISO 3452-1:2013-08","norm_bases":["PN-EN 61109:2010","PN-EN ISO 3452-1:2013-08"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Szczelność między powierzchniami granicznymi / Tightness between boundary surfaces test\nPróba penetracji barwnikiem / Dye penetration test PN-EN 61109:2010 | PN-EN ISO 3452-1:2013-08 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Szczelnosc miedzy powierzchniami granicznymi / Tightness between boundary surfaces test\nProba penetracji barwnikiem / Dye penetration test PN-EN 61109:2010 | PN-EN ISO 3452-1:2013-08","categories":["materials"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Tightness between boundary surfaces test","search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Tightness between boundary surfaces test Dye penetration test / Dye penetration test Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010 | PN-EN ISO 3452-1:2013-08","technique_en":"Dye penetration test / Dye penetration test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 PN-EN 61109:2010 | PN-EN ISO 3452-1:2013-08","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487ac","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Sprawdzenie wymiarów / Verification of the dimensions","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Sprawdzenie wymiarów / Verification of the dimensions","reference":"PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010","norm_bases":["PN-EN 61109:2010","PN-EN 62231:2008","PN-EN 61952:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Sprawdzenie wymiarów / Verification of the dimensions PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Sprawdzenie wymiarow / Verification of the dimensions PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010","categories":["materials"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Verification of the dimensions / Verification of the dimensions","search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Verification of the dimensions / Verification of the dimensions Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 尺寸检验 / Verification of the dimensions 电工材料检测实验室；绝缘子研究组 PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","methodology_zh":"尺寸检验 / Verification of the dimensions"},{"_id":"6a7d7594441eff5f156487ad","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Grubość powłoki / Thickness of the coating","parameters":[{"name":"Zakres: / Range:","range":"do 900 µm / to 900 μm"}],"technique":"Próba ocynkowania / Galvanizing test","techniques":["Próba ocynkowania / Galvanizing test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Grubość powłoki / Thickness of the coating\nZakres: / Range: do 900 µm / to 900 μm\nPróba ocynkowania / Galvanizing test","reference":"PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010 | PN-EN ISO 2178:2016-06","norm_bases":["PN-EN 61109:2010","PN-EN 62231:2008","PN-EN 61952:2010","PN-EN ISO 2178:2016-06"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Grubość powłoki / Thickness of the coating\nZakres: / Range: do 900 µm / to 900 μm\nPróba ocynkowania / Galvanizing test PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010 | PN-EN ISO 2178:2016-06 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Grubosc powloki / Thickness of the coating\nZakres: / Range: do 900 µm / to 900 μm\nProba ocynkowania / Galvanizing test PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010 | PN-EN ISO 2178:2016-06","categories":["materials"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Thickness of the coating","parameters_en":[{"name":"Range:","range":"do 900 µm / to 900 μm"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Thickness of the coating Galvanizing test Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010 | PN-EN ISO 2178:2016-06","technique_en":"Galvanizing test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： PN-EN 61109:2010 | PN-EN 62231:2008 | PN-EN 61952:2010 | PN-EN ISO 2178:2016-06","parameters_zh":[{"name":"范围：","range":"do 900 µm / to 900 μm"}],"test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487ae","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość mechaniczna / Sudden load release","parameters":[{"name":"Zakres: / range:","range":"do 300 kN / to 300 kN"}],"technique":"Próba nagłego zdejmowania obciążenia / Sudden load release","techniques":["Próba nagłego zdejmowania obciążenia / Sudden load release"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość mechaniczna / Sudden load release\nZakres: / range: do 300 kN / to 300 kN\nPróba nagłego zdejmowania obciążenia / Sudden load release","reference":"PN-EN 61109:2010","norm_bases":["PN-EN 61109:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość mechaniczna / Sudden load release\nZakres: / range: do 300 kN / to 300 kN\nPróba nagłego zdejmowania obciążenia / Sudden load release PN-EN 61109:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc mechaniczna / Sudden load release\nZakres: / range: do 300 kN / to 300 kN\nProba naglego zdejmowania obciazenia / Sudden load release PN-EN 61109:2010","categories":["materials"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Sudden load release","parameters_en":[{"name":"range:","range":"do 300 kN / to 300 kN"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Sudden load release Sudden load release test Electrotechnical Materials Testing Laboratory; Insulator Research Group range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010","technique_en":"Sudden load release test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： / range: PN-EN 61109:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","parameters_zh":[{"name":"范围： / range:","range":"do 300 kN / to 300 kN"}]},{"_id":"6a7d7594441eff5f156487af","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość mechaniczna / Tensile load test","parameters":[{"name":"Zakres: / range:","range":"do 300 kN / to 300 kN"}],"technique":"Określanie średniego obciążenia rozciągającego niszczącego / Tensile load test","techniques":["Określanie średniego obciążenia rozciągającego niszczącego / Tensile load test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość mechaniczna / Tensile load test\nZakres: / range: do 300 kN / to 300 kN\nOkreślanie średniego obciążenia rozciągającego niszczącego / Tensile load test","reference":"PN-EN 61109:2010","norm_bases":["PN-EN 61109:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość mechaniczna / Tensile load test\nZakres: / range: do 300 kN / to 300 kN\nOkreślanie średniego obciążenia rozciągającego niszczącego / Tensile load test PN-EN 61109:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc mechaniczna / Tensile load test\nZakres: / range: do 300 kN / to 300 kN\nOkreslanie sredniego obciazenia rozciagajacego niszczacego / Tensile load test PN-EN 61109:2010","categories":["materials"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Mechanical strength Tensile load test","parameters_en":[{"name":"range:","range":"do 300 kN / to 300 kN"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Mechanical strength Tensile load test Determination of the average breaking tensile load Electrotechnical Materials Testing Laboratory; Insulator Research Group range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010","technique_en":"Determination of the average breaking tensile load","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： / range: PN-EN 61109:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","parameters_zh":[{"name":"范围： / range:","range":"do 300 kN / to 300 kN"}]},{"_id":"6a7d7594441eff5f156487b0","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość mechaniczna / Tensile load test (96h test)","parameters":[{"name":"Zakres: / range:","range":"do 300 kN / to 300 kN"}],"technique":"Wielogodzinna próba obciążeniem rozciągającym (próba 96h) / Tensile load test (96h test)","techniques":["Wielogodzinna próba obciążeniem rozciągającym (próba 96h) / Tensile load test (96h test)"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość mechaniczna / Tensile load test (96h test)\nZakres: / range: do 300 kN / to 300 kN\nWielogodzinna próba obciążeniem rozciągającym (próba 96h) / Tensile load test (96h test)","reference":"PN-EN 61109:2010","norm_bases":["PN-EN 61109:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość mechaniczna / Tensile load test (96h test)\nZakres: / range: do 300 kN / to 300 kN\nWielogodzinna próba obciążeniem rozciągającym (próba 96h) / Tensile load test (96h test) PN-EN 61109:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc mechaniczna / Tensile load test (96h test)\nZakres: / range: do 300 kN / to 300 kN\nWielogodzinna proba obciazeniem rozciagajacym (proba 96h) / Tensile load test (96h test) PN-EN 61109:2010","categories":["materials"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Tensile load test (96h test)","parameters_en":[{"name":"range:","range":"do 300 kN / to 300 kN"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Tensile load test (96h test) Multi-hour tensile load test (96h test) Electrotechnical Materials Testing Laboratory; Insulator Research Group range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010","technique_en":"Multi-hour tensile load test (96h test)","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： / range: PN-EN 61109:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","parameters_zh":[{"name":"范围： / range:","range":"do 300 kN / to 300 kN"}]},{"_id":"6a7d7594441eff5f156487b1","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość na rozciąganie / Tensile strength","parameters":[{"name":"Zakres: / range:","range":"do 300 kN / to 300 kN"}],"technique":"Mechaniczna próba obciążeniem rozciągającym / Mechanical tensile load test","techniques":["Mechaniczna próba obciążeniem rozciągającym / Mechanical tensile load test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na rozciąganie / Tensile strength\nZakres: / range: do 300 kN / to 300 kN\nMechaniczna próba obciążeniem rozciągającym / Mechanical tensile load test","reference":"PN-EN 61109:2010 pkt. 13.1 | PN-EN 62231:2008 | PN-EN 60660:2002 | PN-EN 61952:2010","norm_bases":["PN-EN 61109:2010 pkt. 13.1","PN-EN 62231:2008","PN-EN 60660:2002","PN-EN 61952:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość na rozciąganie / Tensile strength\nZakres: / range: do 300 kN / to 300 kN\nMechaniczna próba obciążeniem rozciągającym / Mechanical tensile load test PN-EN 61109:2010 pkt. 13.1 | PN-EN 62231:2008 | PN-EN 60660:2002 | PN-EN 61952:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc na rozciaganie / Tensile strength\nZakres: / range: do 300 kN / to 300 kN\nMechaniczna proba obciazeniem rozciagajacym / Mechanical tensile load test PN-EN 61109:2010 pkt. 13.1 | PN-EN 62231:2008 | PN-EN 60660:2002 | PN-EN 61952:2010","categories":["materials"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Tensile strength / Tensile strength","parameters_en":[{"name":"range:","range":"do 300 kN / to 300 kN"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Tensile strength / Tensile strength Mechanical tensile load test / Mechanical tensile load test Electrotechnical Materials Testing Laboratory; Insulator Research Group range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010 pkt. 13.1 | PN-EN 62231:2008 | PN-EN 60660:2002 | PN-EN 61952:2010","technique_en":"Mechanical tensile load test / Mechanical tensile load test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： / range: PN-EN 61109:2010 pkt. 13.1 | PN-EN 62231:2008 | PN-EN 60660:2002 | PN-EN 61952:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","parameters_zh":[{"name":"范围： / range:","range":"do 300 kN / to 300 kN"}]},{"_id":"6a7d7594441eff5f156487b2","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość na zginanie / Test for mechanical bending strength","parameters":[{"name":"Zakres: / range:","range":"do 25 kN / to 25 kN"}],"technique":"Próba mechanicznej odporności na zginanie / Test for mechanical bending strength","techniques":["Próba mechanicznej odporności na zginanie / Test for mechanical bending strength"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na zginanie / Test for mechanical bending strength\nZakres: / range: do 25 kN / to 25 kN\nPróba mechanicznej odporności na zginanie / Test for mechanical bending strength","reference":"PN-EN 62231:2008 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN 60660:2002 | PN-EN 61952:2010","norm_bases":["PN-EN 62231:2008 pkt. 9.3.1.","PN-EN 61462:2009","PN-EN 60660:2002","PN-EN 61952:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość na zginanie / Test for mechanical bending strength\nZakres: / range: do 25 kN / to 25 kN\nPróba mechanicznej odporności na zginanie / Test for mechanical bending strength PN-EN 62231:2008 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN 60660:2002 | PN-EN 61952:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc na zginanie / Test for mechanical bending strength\nZakres: / range: do 25 kN / to 25 kN\nProba mechanicznej odpornosci na zginanie / Test for mechanical bending strength PN-EN 62231:2008 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN 60660:2002 | PN-EN 61952:2010","categories":["materials"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Test for mechanical bending strength","parameters_en":[{"name":"range:","range":"do 25 kN / to 25 kN"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Test for mechanical bending strength Test for mechanical bending strength Electrotechnical Materials Testing Laboratory; Insulator Research Group range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 62231:2008 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN 60660:2002 | PN-EN 61952:2010","technique_en":"Test for mechanical bending strength","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： / range: PN-EN 62231:2008 pkt. 9.3.1. | PN-EN 61462:2009 | PN-EN 60660:2002 | PN-EN 61952:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","parameters_zh":[{"name":"范围： / range:","range":"do 25 kN / to 25 kN"}]},{"_id":"6a7d7594441eff5f156487b3","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość na ściskanie / Compressive strength test","parameters":[{"name":"Zakres: / Range:","range":"do 300 kN / to 300 kN"}],"technique":"Próba odporności na ściskanie / Compressive strength test","techniques":["Próba odporności na ściskanie / Compressive strength test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na ściskanie / Compressive strength test\nZakres: / Range: do 300 kN / to 300 kN\nPróba odporności na ściskanie / Compressive strength test","reference":"PN-EN 62231:2008","norm_bases":["PN-EN 62231:2008"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość na ściskanie / Compressive strength test\nZakres: / Range: do 300 kN / to 300 kN\nPróba odporności na ściskanie / Compressive strength test PN-EN 62231:2008 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc na sciskanie / Compressive strength test\nZakres: / Range: do 300 kN / to 300 kN\nProba odpornosci na sciskanie / Compressive strength test PN-EN 62231:2008","categories":["materials"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Compressive strength test","parameters_en":[{"name":"Range:","range":"do 300 kN / to 300 kN"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Compressive strength test Compressive strength test Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 62231:2008","technique_en":"Compressive strength test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： PN-EN 62231:2008","parameters_zh":[{"name":"范围：","range":"do 300 kN / to 300 kN"}],"test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487b4","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość na zginanie / Bending Strength","parameters":[{"name":"Zakres: / Range:","range":"do 25 kN / up to 25 kN"}],"technique":"Próba wytrzymałości mechaniczne na zginanie w funkcji temperatury / Mechanical bending strength test as a function of temperature","techniques":["Próba wytrzymałości mechaniczne na zginanie w funkcji temperatury / Mechanical bending strength test as a function of temperature"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na zginanie / Bending Strength\nZakres: / Range: do 25 kN / up to 25 kN\nPróba wytrzymałości mechaniczne na zginanie w funkcji temperatury / Mechanical bending strength test as a function of temperature","reference":"PN-EN 60660:2002","norm_bases":["PN-EN 60660:2002"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość na zginanie / Bending Strength\nZakres: / Range: do 25 kN / up to 25 kN\nPróba wytrzymałości mechaniczne na zginanie w funkcji temperatury / Mechanical bending strength test as a function of temperature PN-EN 60660:2002 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc na zginanie / Bending Strength\nZakres: / Range: do 25 kN / up to 25 kN\nProba wytrzymalosci mechaniczne na zginanie w funkcji temperatury / Mechanical bending strength test as a function of temperature PN-EN 60660:2002","categories":["materials"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Bending strength / Bending Strength","parameters_en":[{"name":"Range:","range":"do 25 kN / up to 25 kN"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Bending strength / Bending Strength Mechanical bending strength test as a function of temperature Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60660:2002","technique_en":"Mechanical bending strength test as a function of temperature","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60660:2002","parameters_zh":[{"name":"范围：","range":"do 25 kN / up to 25 kN"}],"test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487b5","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość mechaniczna / Mechanical strength","parameters":[{"name":"Zakres: / Range:","range":"do 25 kN / up to 25 kN"}],"technique":"Próba odporności na nagłe zmiany temperatury / Test for mechanical bending strength as a function of temperature","techniques":["Próba odporności na nagłe zmiany temperatury / Test for mechanical bending strength as a function of temperature"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość mechaniczna / Mechanical strength\nZakres: / Range: do 25 kN / up to 25 kN\nPróba odporności na nagłe zmiany temperatury / Test for mechanical bending strength as a function of temperature","reference":"PN-EN 60660:2002","norm_bases":["PN-EN 60660:2002"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość mechaniczna / Mechanical strength\nZakres: / Range: do 25 kN / up to 25 kN\nPróba odporności na nagłe zmiany temperatury / Test for mechanical bending strength as a function of temperature PN-EN 60660:2002 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc mechaniczna / Mechanical strength\nZakres: / Range: do 25 kN / up to 25 kN\nProba odpornosci na nagle zmiany temperatury / Test for mechanical bending strength as a function of temperature PN-EN 60660:2002","categories":["materials"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Mechanical strength","parameters_en":[{"name":"Range:","range":"do 25 kN / up to 25 kN"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Mechanical strength Test for mechanical bending strength as a function of temperature Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60660:2002","technique_en":"Test for mechanical bending strength as a function of temperature","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60660:2002","parameters_zh":[{"name":"范围：","range":"do 25 kN / up to 25 kN"}],"test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子"},{"_id":"6a7d7594441eff5f156487b6","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość elektryczna / Reference dry power frequency test","parameters":[{"name":"Zakres: / range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Próba napięciem przemiennym 50 Hz na sucho / Reference dry power frequency test","techniques":["Próba napięciem przemiennym 50 Hz na sucho / Reference dry power frequency test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Reference dry power frequency test\nZakres: / range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem przemiennym 50 Hz na sucho / Reference dry power frequency test","reference":"PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 60060-1:2011","norm_bases":["PN-EN 62217:2013-06","PN-EN 61462:2009","PN-EN 60060-1:2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość elektryczna / Reference dry power frequency test\nZakres: / range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem przemiennym 50 Hz na sucho / Reference dry power frequency test PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 60060-1:2011 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc elektryczna / Reference dry power frequency test\nZakres: / range: (5 - 125) kV / 5 – 125 kV\nProba napieciem przemiennym 50 Hz na sucho / Reference dry power frequency test PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 60060-1:2011","categories":["materials"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Reference dry power frequency test","parameters_en":[{"name":"range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Reference dry power frequency test Reference dry power frequency test Electrotechnical Materials Testing Laboratory; Insulator Research Group range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 60060-1:2011","technique_en":"Reference dry power frequency test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： / range: PN-EN 62217:2013-06 | PN-EN 61462:2009 | PN-EN 60060-1:2011","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","parameters_zh":[{"name":"范围： / range:","range":"(5 - 125) kV / 5 – 125 kV"}]},{"_id":"6a7d7594441eff5f156487b7","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość elektryczna / Reference wet power frequency test","parameters":[{"name":"Zakres: / range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Próba napięciem przemiennym 50 Hz w deszczu / Reference wet power frequency test","techniques":["Próba napięciem przemiennym 50 Hz w deszczu / Reference wet power frequency test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Reference wet power frequency test\nZakres: / range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem przemiennym 50 Hz w deszczu / Reference wet power frequency test","reference":"PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 62231:2008 | PN-EN 61952:2010","norm_bases":["PN-EN 61109:2010","PN-EN 60060-1:2011","PN-EN 62231:2008","PN-EN 61952:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość elektryczna / Reference wet power frequency test\nZakres: / range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem przemiennym 50 Hz w deszczu / Reference wet power frequency test PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 62231:2008 | PN-EN 61952:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc elektryczna / Reference wet power frequency test\nZakres: / range: (5 - 125) kV / 5 – 125 kV\nProba napieciem przemiennym 50 Hz w deszczu / Reference wet power frequency test PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 62231:2008 | PN-EN 61952:2010","categories":["materials"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Reference wet power frequency test","parameters_en":[{"name":"range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Reference wet power frequency test Reference wet power frequency test Electrotechnical Materials Testing Laboratory; Insulator Research Group range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 62231:2008 | PN-EN 61952:2010","technique_en":"Reference wet power frequency test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： / range: PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 62231:2008 | PN-EN 61952:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","parameters_zh":[{"name":"范围： / range:","range":"(5 - 125) kV / 5 – 125 kV"}]},{"_id":"6a7d7594441eff5f156487b8","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","methodology":"Wytrzymałość elektryczna / Impulse voltage test","parameters":[{"name":"Zakres: / range:","range":"(10 - 700) kV / 10 – 700 kV"}],"technique":"Próba napięciem udarowym / Impulse voltage test","techniques":["Próba napięciem udarowym / Impulse voltage test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Impulse voltage test\nZakres: / range: (10 - 700) kV / 10 – 700 kV\nPróba napięciem udarowym / Impulse voltage test","reference":"PN-EN 62217:2013-06 | PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 61462:2009 | PN-EN 62231:2008 | PN-EN 61952:2010","norm_bases":["PN-EN 62217:2013-06","PN-EN 61109:2010","PN-EN 60060-1:2011","PN-EN 61462:2009","PN-EN 62231:2008","PN-EN 61952:2010"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyżej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymałość elektryczna / Impulse voltage test\nZakres: / range: (10 - 700) kV / 10 – 700 kV\nPróba napięciem udarowym / Impulse voltage test PN-EN 62217:2013-06 | PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 61462:2009 | PN-EN 62231:2008 | PN-EN 61952:2010 Izolatory kompozytowe, polimerowe i z tworzyw organicznych powyzej 1 kV / Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Wytrzymalosc elektryczna / Impulse voltage test\nZakres: / range: (10 - 700) kV / 10 – 700 kV\nProba napieciem udarowym / Impulse voltage test PN-EN 62217:2013-06 | PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 61462:2009 | PN-EN 62231:2008 | PN-EN 61952:2010","categories":["materials"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Impulse voltage test","parameters_en":[{"name":"range:","range":"(10 - 700) kV / 10 – 700 kV"}],"search_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV Impulse voltage test Impulse voltage test Electrotechnical Materials Testing Laboratory; Insulator Research Group range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 62217:2013-06 | PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 61462:2009 | PN-EN 62231:2008 | PN-EN 61952:2010","technique_en":"Impulse voltage test","test_object_en":"Composite, polymeric and organic materials insulators for nominal voltages greater then 1kV","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子 电工材料检测实验室；绝缘子研究组 范围： / range: PN-EN 62217:2013-06 | PN-EN 61109:2010 | PN-EN 60060-1:2011 | PN-EN 61462:2009 | PN-EN 62231:2008 | PN-EN 61952:2010","test_object_zh":"额定电压 1 kV 以上的复合、聚合物及有机材料绝缘子","parameters_zh":[{"name":"范围： / range:","range":"(10 - 700) kV / 10 – 700 kV"}]},{"_id":"6a7d7594441eff5f156487b9","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","methodology":"Sprawdzenie wymiarów / Verification of the dimensions","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Sprawdzenie wymiarów / Verification of the dimensions","reference":"PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","norm_bases":["PN-EN 60383-1:2005","PN-EN 60383-1:2024-04"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Sprawdzenie wymiarów / Verification of the dimensions PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 Izolatory ceramiczne do linii napowietrznych o znamionowym napieciu powyzej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Sprawdzenie wymiarow / Verification of the dimensions PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","categories":["other"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Verification of the dimensions / Verification of the dimensions","search_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Verification of the dimensions / Verification of the dimensions Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","test_object_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators 尺寸检验 / Verification of the dimensions 电工材料检测实验室；绝缘子研究组 PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","test_object_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","methodology_zh":"尺寸检验 / Verification of the dimensions"},{"_id":"6a7d7594441eff5f156487ba","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","methodology":"Wytrzymałość elektryczna / Electric strength.","parameters":[{"name":"Zakres: / Range:","range":"(10 - 700) kV / 10 – 700 kV"}],"technique":"Próba napięciem udarowym piorunowym / Lightning impulse withstand voltage tests","techniques":["Próba napięciem udarowym piorunowym / Lightning impulse withstand voltage tests"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nPróba napięciem udarowym piorunowym / Lightning impulse withstand voltage tests","reference":"PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","norm_bases":["PN-EN 60383-1:2005","PN-EN 60060-1:2011","PN-EN 60383-1:2024-04"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nPróba napięciem udarowym piorunowym / Lightning impulse withstand voltage tests PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04 Izolatory ceramiczne do linii napowietrznych o znamionowym napieciu powyzej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Wytrzymalosc elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nProba napieciem udarowym piorunowym / Lightning impulse withstand voltage tests PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength.","parameters_en":[{"name":"Range:","range":"(10 - 700) kV / 10 – 700 kV"}],"search_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Electric strength. Lightning impulse withstand voltage tests / Lightning impulse withstand voltage tests Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","technique_en":"Lightning impulse withstand voltage tests / Lightning impulse withstand voltage tests","test_object_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators 介电强度 / Electric strength. 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","parameters_zh":[{"name":"范围：","range":"(10 - 700) kV / 10 – 700 kV"}],"methodology_zh":"介电强度 / Electric strength.","test_object_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators"},{"_id":"6a7d7594441eff5f156487bb","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","methodology":"Wytrzymałość elektryczna / Electric strength.","parameters":[{"name":"Zakres: / Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Próba napięciem przemiennym 50 Hz na sucho i w deszczu / Nominal power-frequency withstand voltage, dry and wet test, 50 Hz","techniques":["Próba napięciem przemiennym 50 Hz na sucho i w deszczu / Nominal power-frequency withstand voltage, dry and wet test, 50 Hz"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem przemiennym 50 Hz na sucho i w deszczu / Nominal power-frequency withstand voltage, dry and wet test, 50 Hz","reference":"PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","norm_bases":["PN-EN 60383-1:2005","PN-EN 60060-1:2011","PN-EN 60383-1:2024-04"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem przemiennym 50 Hz na sucho i w deszczu / Nominal power-frequency withstand voltage, dry and wet test, 50 Hz PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04 Izolatory ceramiczne do linii napowietrznych o znamionowym napieciu powyzej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Wytrzymalosc elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nProba napieciem przemiennym 50 Hz na sucho i w deszczu / Nominal power-frequency withstand voltage, dry and wet test, 50 Hz PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength.","parameters_en":[{"name":"Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Electric strength. Nominal power-frequency withstand voltage, dry and wet test, 50 Hz Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","technique_en":"Nominal power-frequency withstand voltage, dry and wet test, 50 Hz","test_object_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators 介电强度 / Electric strength. 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","parameters_zh":[{"name":"范围：","range":"(5 - 125) kV / 5 – 125 kV"}],"methodology_zh":"介电强度 / Electric strength.","test_object_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators"},{"_id":"6a7d7594441eff5f156487bc","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","methodology":"Wytrzymałość elektryczna / Electric strength.","parameters":[{"name":"Zakres: / Range:","range":"(10 - 700) kV / 10 – 700 kV"}],"technique":"Próba przebicia napięciem udarowym w powietrzu / Impulse voltage puncture test.","techniques":["Próba przebicia napięciem udarowym w powietrzu / Impulse voltage puncture test."],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nPróba przebicia napięciem udarowym w powietrzu / Impulse voltage puncture test.","reference":"PN EN 61211:2005, | PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","norm_bases":["PN EN 61211:2005,","PN-EN 60383-1:2005","PN-EN 60060-1:2011","PN-EN 60383-1:2024-04"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nPróba przebicia napięciem udarowym w powietrzu / Impulse voltage puncture test. PN EN 61211:2005, | PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04 Izolatory ceramiczne do linii napowietrznych o znamionowym napieciu powyzej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Wytrzymalosc elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nProba przebicia napieciem udarowym w powietrzu / Impulse voltage puncture test. PN EN 61211:2005, | PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","categories":["other"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength.","parameters_en":[{"name":"Range:","range":"(10 - 700) kV / 10 – 700 kV"}],"search_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Electric strength. Impulse voltage puncture test in air. Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN EN 61211:2005, | PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","technique_en":"Impulse voltage puncture test in air.","test_object_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators 介电强度 / Electric strength. 电工材料检测实验室；绝缘子研究组 范围： PN EN 61211:2005, | PN-EN 60383-1:2005 | PN-EN 60060-1:2011 | PN-EN 60383-1:2024-04","parameters_zh":[{"name":"范围：","range":"(10 - 700) kV / 10 – 700 kV"}],"methodology_zh":"介电强度 / Electric strength.","test_object_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators"},{"_id":"6a7d7594441eff5f156487bd","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","methodology":"Odporności na nagłe zmiany temperatury / Resistance to thermal shock","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporności na nagłe zmiany temperatury / Resistance to thermal shock","reference":"PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","norm_bases":["PN-EN 60383-1:2005","PN-EN 60383-1:2024-04"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Odporności na nagłe zmiany temperatury / Resistance to thermal shock PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 Izolatory ceramiczne do linii napowietrznych o znamionowym napieciu powyzej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Odpornosci na nagle zmiany temperatury / Resistance to thermal shock PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Resistance to thermal shock / Resistance to thermal shock","search_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Resistance to thermal shock / Resistance to thermal shock Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","test_object_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators 电工材料检测实验室；绝缘子研究组 PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","test_object_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators"},{"_id":"6a7d7594441eff5f156487be","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","methodology":"Wytrzymałość na rozciąganie / Tensile strength","parameters":[{"name":"Zakres / Range:","range":"do 300 kN / to 300 kN"}],"technique":"Próba termomechaniczna / Thermomechanical test","techniques":["Próba termomechaniczna / Thermomechanical test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na rozciąganie / Tensile strength\nZakres / Range: do 300 kN / to 300 kN\nPróba termomechaniczna / Thermomechanical test","reference":"PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","norm_bases":["PN-EN 60383-1:2005","PN-EN 60383-1:2024-04"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Wytrzymałość na rozciąganie / Tensile strength\nZakres / Range: do 300 kN / to 300 kN\nPróba termomechaniczna / Thermomechanical test PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 Izolatory ceramiczne do linii napowietrznych o znamionowym napieciu powyzej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Wytrzymalosc na rozciaganie / Tensile strength\nZakres / Range: do 300 kN / to 300 kN\nProba termomechaniczna / Thermomechanical test PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","categories":["other"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Tensile strength / Tensile strength","parameters_en":[{"name":"Range:","range":"do 300 kN / to 300 kN"}],"search_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Tensile strength / Tensile strength Thermomechanical test Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","technique_en":"Thermomechanical test","test_object_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators 电工材料检测实验室；绝缘子研究组 PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","test_object_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators"},{"_id":"6a7d7594441eff5f156487bf","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","methodology":"Próba wytrzymałości mechanicznej / Mechanical strength test","parameters":[{"name":"- metoda próby izolatorów stojących i wsporczych izolatorów liniowych / - method of the test for line and line post insulators."},{"name":"- metoda próby izolatorów wiszących / - method of the test for long rod line insulators."}],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Próba wytrzymałości mechanicznej / Mechanical strength test\nZakres:\n- metoda próby izolatorów stojących i wsporczych izolatorów liniowych / - method of the test for line and line post insulators.\n- metoda próby izolatorów wiszących / - method of the test for long rod line insulators.","reference":"PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","norm_bases":["PN-EN 60383-1:2005","PN-EN 60383-1:2024-04"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Próba wytrzymałości mechanicznej / Mechanical strength test\nZakres:\n- metoda próby izolatorów stojących i wsporczych izolatorów liniowych / - method of the test for line and line post insulators.\n- metoda próby izolatorów wiszących / - method of the test for long rod line insulators. PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 Izolatory ceramiczne do linii napowietrznych o znamionowym napieciu powyzej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Proba wytrzymalosci mechanicznej / Mechanical strength test\nZakres:\n- metoda proby izolatorow stojacych i wsporczych izolatorow liniowych / - method of the test for line and line post insulators.\n- metoda proby izolatorow wiszacych / - method of the test for long rod line insulators. PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","categories":["other"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Mechanical strength test","parameters_en":[{"name":"- method of the test for line and line post insulators."},{"name":"- method of the test for long rod line insulators."}],"search_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Mechanical strength test Electrotechnical Materials Testing Laboratory; Insulator Research Group - method of the test for line and line post insulators. - method of the test for long rod line insulators. Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","test_object_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators 电工材料检测实验室；绝缘子研究组 PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04","test_object_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators"},{"_id":"6a7d7594441eff5f156487c0","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","methodology":"Grubość powłoki / Thickness of the coating.","parameters":[{"name":"Zakres: / Range:","range":"do 900 µm / to 900 μm"}],"technique":"Próba ocynkowania / Test of galvanization.","techniques":["Próba ocynkowania / Test of galvanization."],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Grubość powłoki / Thickness of the coating.\nZakres: / Range: do 900 µm / to 900 μm\nPróba ocynkowania / Test of galvanization.","reference":"PN-EN 60383-1:2005, | PN-EN ISO 2178:2016-06 | PN-EN 60383-1:2024-04","norm_bases":["PN-EN 60383-1:2005,","PN-EN ISO 2178:2016-06","PN-EN 60383-1:2024-04"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory ceramiczne do linii napowietrznych o znamionowym napięciu powyżej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Grubość powłoki / Thickness of the coating.\nZakres: / Range: do 900 µm / to 900 μm\nPróba ocynkowania / Test of galvanization. PN-EN 60383-1:2005, | PN-EN ISO 2178:2016-06 | PN-EN 60383-1:2024-04 Izolatory ceramiczne do linii napowietrznych o znamionowym napieciu powyzej 1 kV. Izolatory ceramiczne trakcyjne / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Grubosc powloki / Thickness of the coating.\nZakres: / Range: do 900 µm / to 900 μm\nProba ocynkowania / Test of galvanization. PN-EN 60383-1:2005, | PN-EN ISO 2178:2016-06 | PN-EN 60383-1:2024-04","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Thickness of the coating.","parameters_en":[{"name":"Range:","range":"do 900 µm / to 900 μm"}],"search_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators Thickness of the coating. Test of galvanization / Test of galvanization. Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60383-1:2005, | PN-EN ISO 2178:2016-06 | PN-EN 60383-1:2024-04","technique_en":"Test of galvanization / Test of galvanization.","test_object_en":"Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60383-1:2005, | PN-EN ISO 2178:2016-06 | PN-EN 60383-1:2024-04","parameters_zh":[{"name":"范围：","range":"do 900 µm / to 900 μm"}],"test_object_zh":"额定电压 1 kV 以上架空线路用陶瓷绝缘子。牵引用陶瓷绝缘子 / Insulators for overhead lines with a nominal voltage above 1kV. Traction ceramic insulators"},{"_id":"6a7d7594441eff5f156487c1","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","methodology":"Sprawdzenie wymiarów / Verification of the dimensions","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Sprawdzenie wymiarów / Verification of the dimensions","reference":"PN-EN 60168:1999","norm_bases":["PN-EN 60168:1999"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Sprawdzenie wymiarów / Verification of the dimensions PN-EN 60168:1999 Izolatory wsporcze wnetrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napieciu powyzej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Sprawdzenie wymiarow / Verification of the dimensions PN-EN 60168:1999","categories":["materials"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Verification of the dimensions / Verification of the dimensions","search_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Verification of the dimensions / Verification of the dimensions Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60168:1999","test_object_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V 尺寸检验 / Verification of the dimensions 电工材料检测实验室；绝缘子研究组 PN-EN 60168:1999","test_object_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","methodology_zh":"尺寸检验 / Verification of the dimensions"},{"_id":"6a7d7594441eff5f156487c2","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","methodology":"Wytrzymałość elektryczna / Electric strength.","parameters":[{"name":"Zakres: / Range:","range":"(10 - 700) kV / 10 – 700 kV"}],"technique":"Próba napięciem udarowym piorunowym / Lightning impulse withstand voltage tests","techniques":["Próba napięciem udarowym piorunowym / Lightning impulse withstand voltage tests"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nPróba napięciem udarowym piorunowym / Lightning impulse withstand voltage tests","reference":"PN-EN 60168:1999 | PN-EN 60060-1:2011","norm_bases":["PN-EN 60168:1999","PN-EN 60060-1:2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nPróba napięciem udarowym piorunowym / Lightning impulse withstand voltage tests PN-EN 60168:1999 | PN-EN 60060-1:2011 Izolatory wsporcze wnetrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napieciu powyzej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Wytrzymalosc elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nProba napieciem udarowym piorunowym / Lightning impulse withstand voltage tests PN-EN 60168:1999 | PN-EN 60060-1:2011","categories":["materials"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength.","parameters_en":[{"name":"Range:","range":"(10 - 700) kV / 10 – 700 kV"}],"search_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Electric strength. Lightning impulse withstand voltage tests / Lightning impulse withstand voltage tests Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60168:1999 | PN-EN 60060-1:2011","technique_en":"Lightning impulse withstand voltage tests / Lightning impulse withstand voltage tests","test_object_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V 介电强度 / Electric strength. 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60168:1999 | PN-EN 60060-1:2011","parameters_zh":[{"name":"范围：","range":"(10 - 700) kV / 10 – 700 kV"}],"methodology_zh":"介电强度 / Electric strength.","test_object_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V"},{"_id":"6a7d7594441eff5f156487c3","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","methodology":"Wytrzymałość elektryczna / Electric strength.","parameters":[{"name":"Zakres: / Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Próba napięciem wytrzymywanym 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz","techniques":["Próba napięciem wytrzymywanym 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem wytrzymywanym 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz","reference":"PN-EN 60168:1999 | PN-EN 60060-1:2011","norm_bases":["PN-EN 60168:1999","PN-EN 60060-1:2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem wytrzymywanym 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz PN-EN 60168:1999 | PN-EN 60060-1:2011 Izolatory wsporcze wnetrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napieciu powyzej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Wytrzymalosc elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nProba napieciem wytrzymywanym 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz PN-EN 60168:1999 | PN-EN 60060-1:2011","categories":["materials"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength.","parameters_en":[{"name":"Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Electric strength. Nominal power-frequency withstand voltage, dry test, 50 Hz Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60168:1999 | PN-EN 60060-1:2011","technique_en":"Nominal power-frequency withstand voltage, dry test, 50 Hz","test_object_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V 介电强度 / Electric strength. 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60168:1999 | PN-EN 60060-1:2011","parameters_zh":[{"name":"范围：","range":"(5 - 125) kV / 5 – 125 kV"}],"methodology_zh":"介电强度 / Electric strength.","test_object_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V"},{"_id":"6a7d7594441eff5f156487c4","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","methodology":"Wytrzymałość elektryczna / Electric strength.","parameters":[{"name":"Zakres: / Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Próba napięciem przemiennym 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz","techniques":["Próba napięciem przemiennym 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem przemiennym 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz","reference":"PN-EN 60168:1999 | PN-EN 60060-1:2011","norm_bases":["PN-EN 60168:1999","PN-EN 60060-1:2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem przemiennym 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz PN-EN 60168:1999 | PN-EN 60060-1:2011 Izolatory wsporcze wnetrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napieciu powyzej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Wytrzymalosc elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nProba napieciem przemiennym 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz PN-EN 60168:1999 | PN-EN 60060-1:2011","categories":["materials"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength.","parameters_en":[{"name":"Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Electric strength. Nominal power-frequency withstand voltage, wet test, 50 Hz Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60168:1999 | PN-EN 60060-1:2011","technique_en":"Nominal power-frequency withstand voltage, wet test, 50 Hz","test_object_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V 介电强度 / Electric strength. 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60168:1999 | PN-EN 60060-1:2011","parameters_zh":[{"name":"范围：","range":"(5 - 125) kV / 5 – 125 kV"}],"methodology_zh":"介电强度 / Electric strength.","test_object_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V"},{"_id":"6a7d7594441eff5f156487c5","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","methodology":"Odporności na nagłe zmiany temperatury / Resistance to thermal shock","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporności na nagłe zmiany temperatury / Resistance to thermal shock","reference":"PN-EN 60168:1999","norm_bases":["PN-EN 60168:1999"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Odporności na nagłe zmiany temperatury / Resistance to thermal shock PN-EN 60168:1999 Izolatory wsporcze wnetrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napieciu powyzej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Odpornosci na nagle zmiany temperatury / Resistance to thermal shock PN-EN 60168:1999","categories":["materials"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Resistance to thermal shock / Resistance to thermal shock","search_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Resistance to thermal shock / Resistance to thermal shock Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60168:1999","test_object_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V 电工材料检测实验室；绝缘子研究组 PN-EN 60168:1999","test_object_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V"},{"_id":"6a7d7594441eff5f156487c6","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","methodology":"Wytrzymałość na zginanie / Bending strength.","parameters":[{"name":"Zakres: / Range:","range":"do 25 kN / to 25 kN"}],"technique":"Próba wytrzymałości mechanicznej na zginanie / Mechanical bending strength test.","techniques":["Próba wytrzymałości mechanicznej na zginanie / Mechanical bending strength test."],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na zginanie / Bending strength.\nZakres: / Range: do 25 kN / to 25 kN\nPróba wytrzymałości mechanicznej na zginanie / Mechanical bending strength test.","reference":"PN-EN 60168:1999","norm_bases":["PN-EN 60168:1999"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Wytrzymałość na zginanie / Bending strength.\nZakres: / Range: do 25 kN / to 25 kN\nPróba wytrzymałości mechanicznej na zginanie / Mechanical bending strength test. PN-EN 60168:1999 Izolatory wsporcze wnetrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napieciu powyzej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Wytrzymalosc na zginanie / Bending strength.\nZakres: / Range: do 25 kN / to 25 kN\nProba wytrzymalosci mechanicznej na zginanie / Mechanical bending strength test. PN-EN 60168:1999","categories":["materials"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Bending strength / Bending strength.","parameters_en":[{"name":"Range:","range":"do 25 kN / to 25 kN"}],"search_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Bending strength / Bending strength. Mechanical bending strength test. Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60168:1999","technique_en":"Mechanical bending strength test.","test_object_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60168:1999","parameters_zh":[{"name":"范围：","range":"do 25 kN / to 25 kN"}],"test_object_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V"},{"_id":"6a7d7594441eff5f156487c7","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","methodology":"Grubość powłoki / Thickness of the coating","parameters":[{"name":"Zakres: / Range:","range":"do 900 µm / to 900 μm"}],"technique":"Próba ocynkowania / Test of galvanization.","techniques":["Próba ocynkowania / Test of galvanization."],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Grubość powłoki / Thickness of the coating\nZakres: / Range: do 900 µm / to 900 μm\nPróba ocynkowania / Test of galvanization.","reference":"PN-EN 60168:1999 | PN-EN ISO 2178:2016-06","norm_bases":["PN-EN 60168:1999","PN-EN ISO 2178:2016-06"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wsporcze wnętrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napięciu powyżej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Grubość powłoki / Thickness of the coating\nZakres: / Range: do 900 µm / to 900 μm\nPróba ocynkowania / Test of galvanization. PN-EN 60168:1999 | PN-EN ISO 2178:2016-06 Izolatory wsporcze wnetrzowe i napowietrzne ceramiczne lub szklane do sieci o znamionowym napieciu powyzej 1000 V / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Grubosc powloki / Thickness of the coating\nZakres: / Range: do 900 µm / to 900 μm\nProba ocynkowania / Test of galvanization. PN-EN 60168:1999 | PN-EN ISO 2178:2016-06","categories":["materials"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Thickness of the coating","parameters_en":[{"name":"Range:","range":"do 900 µm / to 900 μm"}],"search_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V Thickness of the coating Test of galvanization / Test of galvanization. Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60168:1999 | PN-EN ISO 2178:2016-06","technique_en":"Test of galvanization / Test of galvanization.","test_object_en":"Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60168:1999 | PN-EN ISO 2178:2016-06","parameters_zh":[{"name":"范围：","range":"do 900 µm / to 900 μm"}],"test_object_zh":"标称电压 1000 V 以上系统用户内与户外陶瓷或玻璃支柱绝缘子 / Indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V"},{"_id":"6a7d7594441eff5f156487c8","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators","methodology":"Sprawdzenie wymiarów / Verification of the dimensions","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Sprawdzenie wymiarów / Verification of the dimensions","reference":"PN-E-91030-1:1996","norm_bases":["PN-E-91030-1:1996"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Sprawdzenie wymiarów / Verification of the dimensions PN-E-91030-1:1996 Elektroenergetyczne izolatory niskonapieciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Sprawdzenie wymiarow / Verification of the dimensions PN-E-91030-1:1996","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Verification of the dimensions / Verification of the dimensions","search_en":"Low voltage power insulators – Ceramic insulators Verification of the dimensions / Verification of the dimensions Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-E-91030-1:1996","test_object_en":"Low voltage power insulators – Ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators 尺寸检验 / Verification of the dimensions 电工材料检测实验室；绝缘子研究组 PN-E-91030-1:1996","test_object_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators","methodology_zh":"尺寸检验 / Verification of the dimensions"},{"_id":"6a7d7594441eff5f156487c9","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators","methodology":"Sprawdzenie masy / Verification of the weight","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Sprawdzenie masy / Verification of the weight","reference":"PN-E-91030-1:1996","norm_bases":["PN-E-91030-1:1996"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Sprawdzenie masy / Verification of the weight PN-E-91030-1:1996 Elektroenergetyczne izolatory niskonapieciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Sprawdzenie masy / Verification of the weight PN-E-91030-1:1996","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Verification of the weight","search_en":"Low voltage power insulators – Ceramic insulators Verification of the weight Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-E-91030-1:1996","test_object_en":"Low voltage power insulators – Ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators 电工材料检测实验室；绝缘子研究组 PN-E-91030-1:1996","test_object_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators"},{"_id":"6a7d7594441eff5f156487ca","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators","methodology":"Próba odporności na nagłe zmiany temperatury / Resistance to thermal shock","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Próba odporności na nagłe zmiany temperatury / Resistance to thermal shock","reference":"PN-E-91030-1:1996","norm_bases":["PN-E-91030-1:1996"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Próba odporności na nagłe zmiany temperatury / Resistance to thermal shock PN-E-91030-1:1996 Elektroenergetyczne izolatory niskonapieciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Proba odpornosci na nagle zmiany temperatury / Resistance to thermal shock PN-E-91030-1:1996","categories":["other"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Resistance to thermal shock test","search_en":"Low voltage power insulators – Ceramic insulators Resistance to thermal shock test Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-E-91030-1:1996","test_object_en":"Low voltage power insulators – Ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators 电工材料检测实验室；绝缘子研究组 PN-E-91030-1:1996","test_object_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators"},{"_id":"6a7d7594441eff5f156487cb","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators","methodology":"Wytrzymałość elektryczna / Electric strength","parameters":[{"name":"Zakres: / Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Próba napięciem 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz","techniques":["Próba napięciem 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz","reference":"PN-E-91030-1:1996 | PN-EN 60060-1:2011","norm_bases":["PN-E-91030-1:1996","PN-EN 60060-1:2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Wytrzymałość elektryczna / Electric strength\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz PN-E-91030-1:1996 | PN-EN 60060-1:2011 Elektroenergetyczne izolatory niskonapieciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Wytrzymalosc elektryczna / Electric strength\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nProba napieciem 50 Hz na sucho / Nominal power-frequency withstand voltage, dry test, 50 Hz PN-E-91030-1:1996 | PN-EN 60060-1:2011","categories":["other"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength / Electric strength","parameters_en":[{"name":"Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Low voltage power insulators – Ceramic insulators Electric strength / Electric strength Nominal power-frequency withstand voltage, dry test, 50 Hz Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-E-91030-1:1996 | PN-EN 60060-1:2011","technique_en":"Nominal power-frequency withstand voltage, dry test, 50 Hz","test_object_en":"Low voltage power insulators – Ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators 电工材料检测实验室；绝缘子研究组 范围： PN-E-91030-1:1996 | PN-EN 60060-1:2011","parameters_zh":[{"name":"范围：","range":"(5 - 125) kV / 5 – 125 kV"}],"test_object_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators"},{"_id":"6a7d7594441eff5f156487cc","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators","methodology":"Wytrzymałość elektryczna / Electric strength.","parameters":[{"name":"Zakres: / Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Próba znamionowym wytrzymywanym napięciem 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz","techniques":["Próba znamionowym wytrzymywanym napięciem 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba znamionowym wytrzymywanym napięciem 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz","reference":"PN-E-91030-1:1996 | PN-EN 60060-1:2011","norm_bases":["PN-E-91030-1:1996","PN-EN 60060-1:2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba znamionowym wytrzymywanym napięciem 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz PN-E-91030-1:1996 | PN-EN 60060-1:2011 Elektroenergetyczne izolatory niskonapieciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Wytrzymalosc elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nProba znamionowym wytrzymywanym napieciem 50 Hz w deszczu / Nominal power-frequency withstand voltage, wet test, 50 Hz PN-E-91030-1:1996 | PN-EN 60060-1:2011","categories":["other"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength.","parameters_en":[{"name":"Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Low voltage power insulators – Ceramic insulators Electric strength. Nominal power-frequency withstand voltage, wet test, 50 Hz Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-E-91030-1:1996 | PN-EN 60060-1:2011","technique_en":"Nominal power-frequency withstand voltage, wet test, 50 Hz","test_object_en":"Low voltage power insulators – Ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators 介电强度 / Electric strength. 电工材料检测实验室；绝缘子研究组 范围： PN-E-91030-1:1996 | PN-EN 60060-1:2011","parameters_zh":[{"name":"范围：","range":"(5 - 125) kV / 5 – 125 kV"}],"methodology_zh":"介电强度 / Electric strength.","test_object_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators"},{"_id":"6a7d7594441eff5f156487cd","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators","methodology":"Wytrzymałość na zginanie / Tensile strength. Wytrzymałość na rozciąganie / Bending strength.","parameters":[{"name":"Zakres: / Range:","range":"do 25 kN / to 25 kN."},{"name":"Zakres: / Range:","range":"do 300 kN / to 300 kN."}],"technique":"Próba wytrzymałości mechanicznej na zginanie / Mechanical bending strength test. Próba wytrzymałości mechanicznej na rozciąganie / Mechanical tensile strength test.","techniques":["Próba wytrzymałości mechanicznej na zginanie / Mechanical bending strength test. Próba wytrzymałości mechanicznej na rozciąganie / Mechanical tensile strength test."],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na zginanie / Tensile strength. Wytrzymałość na rozciąganie / Bending strength.\nZakres:\nZakres: / Range: do 25 kN / to 25 kN.\nZakres: / Range: do 300 kN / to 300 kN.\nPróba wytrzymałości mechanicznej na zginanie / Mechanical bending strength test. Próba wytrzymałości mechanicznej na rozciąganie / Mechanical tensile strength test.","reference":"PN-E-91030-1:1996","norm_bases":["PN-E-91030-1:1996"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Wytrzymałość na zginanie / Tensile strength. Wytrzymałość na rozciąganie / Bending strength.\nZakres:\nZakres: / Range: do 25 kN / to 25 kN.\nZakres: / Range: do 300 kN / to 300 kN.\nPróba wytrzymałości mechanicznej na zginanie / Mechanical bending strength test. Próba wytrzymałości mechanicznej na rozciąganie / Mechanical tensile strength test. PN-E-91030-1:1996 Elektroenergetyczne izolatory niskonapieciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Wytrzymalosc na zginanie / Tensile strength. Wytrzymalosc na rozciaganie / Bending strength.\nZakres:\nZakres: / Range: do 25 kN / to 25 kN.\nZakres: / Range: do 300 kN / to 300 kN.\nProba wytrzymalosci mechanicznej na zginanie / Mechanical bending strength test. Proba wytrzymalosci mechanicznej na rozciaganie / Mechanical tensile strength test. PN-E-91030-1:1996","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Tensile strength. Bending strength.","parameters_en":[{"name":"Range:","range":"do 25 kN / to 25 kN."},{"name":"Range:","range":"do 300 kN / to 300 kN."}],"search_en":"Low voltage power insulators – Ceramic insulators Tensile strength. Bending strength. Mechanical bending strength test. Mechanical tensile strength test. Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-E-91030-1:1996","technique_en":"Mechanical bending strength test. Mechanical tensile strength test.","test_object_en":"Low voltage power insulators – Ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators 电工材料检测实验室；绝缘子研究组 范围： 范围： PN-E-91030-1:1996","parameters_zh":[{"name":"范围：","range":"do 25 kN / to 25 kN."},{"name":"范围：","range":"do 300 kN / to 300 kN."}],"test_object_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators"},{"_id":"6a7d7594441eff5f156487ce","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators","methodology":"Pęknięcia, wtrąciny, defekty / Cracks and defects.","parameters":[],"technique":"Próba przełamu czerepu / Inspection of the fracture surface of ceramic body","techniques":["Próba przełamu czerepu / Inspection of the fracture surface of ceramic body"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Pęknięcia, wtrąciny, defekty / Cracks and defects.\nPróba przełamu czerepu / Inspection of the fracture surface of ceramic body","reference":"PN-E-91030-1:1996 | PN-E-91030-3:1997 | PN-E-91030-4:1997","norm_bases":["PN-E-91030-1:1996","PN-E-91030-3:1997","PN-E-91030-4:1997"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektroenergetyczne izolatory niskonapięciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Pęknięcia, wtrąciny, defekty / Cracks and defects.\nPróba przełamu czerepu / Inspection of the fracture surface of ceramic body PN-E-91030-1:1996 | PN-E-91030-3:1997 | PN-E-91030-4:1997 Elektroenergetyczne izolatory niskonapieciowe – Izolatory ceramiczne / Low voltage insulators – Ceramic insulators Pekniecia, wtraciny, defekty / Cracks and defects.\nProba przelamu czerepu / Inspection of the fracture surface of ceramic body PN-E-91030-1:1996 | PN-E-91030-3:1997 | PN-E-91030-4:1997","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Cracks, inclusions, defects.","search_en":"Low voltage power insulators – Ceramic insulators Cracks, inclusions, defects. Inspection of the fracture surface of ceramic body Electrotechnical Materials Testing Laboratory; Insulator Research Group Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-E-91030-1:1996 | PN-E-91030-3:1997 | PN-E-91030-4:1997","technique_en":"Inspection of the fracture surface of ceramic body","test_object_en":"Low voltage power insulators – Ceramic insulators","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators 电工材料检测实验室；绝缘子研究组 PN-E-91030-1:1996 | PN-E-91030-3:1997 | PN-E-91030-4:1997","test_object_zh":"低压电力绝缘子 － 陶瓷绝缘子 / Low voltage insulators – Ceramic insulators"},{"_id":"6a7d7594441eff5f156487cf","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory przepustowe na napięcie przemienne pow. 1000 V / Insulated bushings for alternating voltages above 1000V","methodology":"Wytrzymałość elektryczna / Electric strength.","parameters":[{"name":"Zakres: / Range:","range":"(10 - 700) kV / 10 – 700 kV"}],"technique":"Próba napięciem udarowym / Lightning impulse withstand voltage tests","techniques":["Próba napięciem udarowym / Lightning impulse withstand voltage tests"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nPróba napięciem udarowym / Lightning impulse withstand voltage tests","reference":"PN-EN 60137:2018-02 | PN-EN 60060-1:2011","norm_bases":["PN-EN 60137:2018-02","PN-EN 60060-1:2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory przepustowe na napięcie przemienne pow. 1000 V / Insulated bushings for alternating voltages above 1000V Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nPróba napięciem udarowym / Lightning impulse withstand voltage tests PN-EN 60137:2018-02 | PN-EN 60060-1:2011 Izolatory przepustowe na napiecie przemienne pow. 1000 V / Insulated bushings for alternating voltages above 1000V Wytrzymalosc elektryczna / Electric strength.\nZakres: / Range: (10 - 700) kV / 10 – 700 kV\nProba napieciem udarowym / Lightning impulse withstand voltage tests PN-EN 60137:2018-02 | PN-EN 60060-1:2011","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength.","parameters_en":[{"name":"Range:","range":"(10 - 700) kV / 10 – 700 kV"}],"search_en":"Insulated bushings for alternating voltages above 1000V Electric strength. Lightning impulse withstand voltage tests Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60137:2018-02 | PN-EN 60060-1:2011","technique_en":"Lightning impulse withstand voltage tests","test_object_en":"Insulated bushings for alternating voltages above 1000V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"1000 V 以上交流电压用套管绝缘子 / Insulated bushings for alternating voltages above 1000V 介电强度 / Electric strength. 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60137:2018-02 | PN-EN 60060-1:2011","parameters_zh":[{"name":"范围：","range":"(10 - 700) kV / 10 – 700 kV"}],"methodology_zh":"介电强度 / Electric strength.","test_object_zh":"1000 V 以上交流电压用套管绝缘子 / Insulated bushings for alternating voltages above 1000V"},{"_id":"6a7d7594441eff5f156487d0","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory przepustowe na napięcie przemienne pow. 1000 V / Insulated bushings for alternating voltages above 1000V","methodology":"Wytrzymałość elektryczna / Electric strength.","parameters":[{"name":"Zakres: / Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"technique":"Próba napięciem 50 Hz na sucho lub w deszczu / Nominal power-frequency withstand voltage, dry or wet test, 50 Hz","techniques":["Próba napięciem 50 Hz na sucho lub w deszczu / Nominal power-frequency withstand voltage, dry or wet test, 50 Hz"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem 50 Hz na sucho lub w deszczu / Nominal power-frequency withstand voltage, dry or wet test, 50 Hz","reference":"PN-EN 60137:2018-02 | PN-EN 60060-1:2011","norm_bases":["PN-EN 60137:2018-02","PN-EN 60060-1:2011"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory przepustowe na napięcie przemienne pow. 1000 V / Insulated bushings for alternating voltages above 1000V Wytrzymałość elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nPróba napięciem 50 Hz na sucho lub w deszczu / Nominal power-frequency withstand voltage, dry or wet test, 50 Hz PN-EN 60137:2018-02 | PN-EN 60060-1:2011 Izolatory przepustowe na napiecie przemienne pow. 1000 V / Insulated bushings for alternating voltages above 1000V Wytrzymalosc elektryczna / Electric strength.\nZakres: / Range: (5 - 125) kV / 5 – 125 kV\nProba napieciem 50 Hz na sucho lub w deszczu / Nominal power-frequency withstand voltage, dry or wet test, 50 Hz PN-EN 60137:2018-02 | PN-EN 60060-1:2011","categories":["other"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electric strength.","parameters_en":[{"name":"Range:","range":"(5 - 125) kV / 5 – 125 kV"}],"search_en":"Insulated bushings for alternating voltages above 1000V Electric strength. Nominal power-frequency withstand voltage, dry or wet test, 50 Hz Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60137:2018-02 | PN-EN 60060-1:2011","technique_en":"Nominal power-frequency withstand voltage, dry or wet test, 50 Hz","test_object_en":"Insulated bushings for alternating voltages above 1000V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"1000 V 以上交流电压用套管绝缘子 / Insulated bushings for alternating voltages above 1000V 介电强度 / Electric strength. 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60137:2018-02 | PN-EN 60060-1:2011","parameters_zh":[{"name":"范围：","range":"(5 - 125) kV / 5 – 125 kV"}],"methodology_zh":"介电强度 / Electric strength.","test_object_zh":"1000 V 以上交流电压用套管绝缘子 / Insulated bushings for alternating voltages above 1000V"},{"_id":"6a7d7594441eff5f156487d1","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Izolatory przepustowe na napięcie przemienne pow. 1000 V / Insulated bushings for alternating voltages above 1000V","methodology":"Wytrzymałość na zginanie / Bending strength.","parameters":[{"name":"Zakres: / Range:","range":"do 25 kN / to 25 kN."}],"technique":"Próba odporności na zginanie (tylko w poziomie) / Mechanical bending strength test (only horizontal).","techniques":["Próba odporności na zginanie (tylko w poziomie) / Mechanical bending strength test (only horizontal)."],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na zginanie / Bending strength.\nZakres: / Range: do 25 kN / to 25 kN.\nPróba odporności na zginanie (tylko w poziomie) / Mechanical bending strength test (only horizontal).","reference":"PN-EN 60137:2018-02","norm_bases":["PN-EN 60137:2018-02"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory przepustowe na napięcie przemienne pow. 1000 V / Insulated bushings for alternating voltages above 1000V Wytrzymałość na zginanie / Bending strength.\nZakres: / Range: do 25 kN / to 25 kN.\nPróba odporności na zginanie (tylko w poziomie) / Mechanical bending strength test (only horizontal). PN-EN 60137:2018-02 Izolatory przepustowe na napiecie przemienne pow. 1000 V / Insulated bushings for alternating voltages above 1000V Wytrzymalosc na zginanie / Bending strength.\nZakres: / Range: do 25 kN / to 25 kN.\nProba odpornosci na zginanie (tylko w poziomie) / Mechanical bending strength test (only horizontal). PN-EN 60137:2018-02","categories":["other"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Bending strength / Bending strength.","parameters_en":[{"name":"Range:","range":"do 25 kN / to 25 kN."}],"search_en":"Insulated bushings for alternating voltages above 1000V Bending strength / Bending strength. Mechanical bending strength test (only horizontal). Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60137:2018-02","technique_en":"Mechanical bending strength test (only horizontal).","test_object_en":"Insulated bushings for alternating voltages above 1000V","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"1000 V 以上交流电压用套管绝缘子 / Insulated bushings for alternating voltages above 1000V 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60137:2018-02","parameters_zh":[{"name":"范围：","range":"do 25 kN / to 25 kN."}],"test_object_zh":"1000 V 以上交流电压用套管绝缘子 / Insulated bushings for alternating voltages above 1000V"},{"_id":"6a7d7594441eff5f156487d2","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Beziskiernikowe ograniczniki przepięć z tlenków metali do sieci prądu przemiennego / Spark-free metal oxide surge arresters for AC networks","methodology":"Wytrzymałość na zginanie / Bending Strength","parameters":[{"name":"Zakres: / Range:","range":"do 25 kN / up to 25 kN"}],"technique":"Próba odporności na zginanie / Bending Resistance Test","techniques":["Próba odporności na zginanie / Bending Resistance Test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na zginanie / Bending Strength\nZakres: / Range: do 25 kN / up to 25 kN\nPróba odporności na zginanie / Bending Resistance Test","reference":"PN-EN 60099-4:2015-01","norm_bases":["PN-EN 60099-4:2015-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beziskiernikowe ograniczniki przepięć z tlenków metali do sieci prądu przemiennego / Spark-free metal oxide surge arresters for AC networks Wytrzymałość na zginanie / Bending Strength\nZakres: / Range: do 25 kN / up to 25 kN\nPróba odporności na zginanie / Bending Resistance Test PN-EN 60099-4:2015-01 Beziskiernikowe ograniczniki przepiec z tlenkow metali do sieci pradu przemiennego / Spark-free metal oxide surge arresters for AC networks Wytrzymalosc na zginanie / Bending Strength\nZakres: / Range: do 25 kN / up to 25 kN\nProba odpornosci na zginanie / Bending Resistance Test PN-EN 60099-4:2015-01","categories":["materials"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Bending strength / Bending Strength","parameters_en":[{"name":"Range:","range":"do 25 kN / up to 25 kN"}],"search_en":"Spark-free metal oxide surge arresters for AC networks Bending strength / Bending Strength Bending Resistance Test Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60099-4:2015-01","technique_en":"Bending Resistance Test","test_object_en":"Spark-free metal oxide surge arresters for AC networks","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"交流电网用无间隙金属氧化物避雷器 / Spark-free metal oxide surge arresters for AC networks 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60099-4:2015-01","parameters_zh":[{"name":"范围：","range":"do 25 kN / up to 25 kN"}],"test_object_zh":"交流电网用无间隙金属氧化物避雷器 / Spark-free metal oxide surge arresters for AC networks"},{"_id":"6a7d7594441eff5f156487d3","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Beziskiernikowe ograniczniki przepięć z tlenków metali do sieci prądu przemiennego / Spark-free metal oxide surge arresters for AC networks","methodology":"Wytrzymałość na rozciąganie / Tensile Strength","parameters":[{"name":"Zakres: / Range:","range":"do 300 kN / up to 300 kN"}],"technique":"Próba odporności na rozciąganie / Tensile Strength Test","techniques":["Próba odporności na rozciąganie / Tensile Strength Test"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość na rozciąganie / Tensile Strength\nZakres: / Range: do 300 kN / up to 300 kN\nPróba odporności na rozciąganie / Tensile Strength Test","reference":"PN-EN 60099-4:2015-01","norm_bases":["PN-EN 60099-4:2015-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beziskiernikowe ograniczniki przepięć z tlenków metali do sieci prądu przemiennego / Spark-free metal oxide surge arresters for AC networks Wytrzymałość na rozciąganie / Tensile Strength\nZakres: / Range: do 300 kN / up to 300 kN\nPróba odporności na rozciąganie / Tensile Strength Test PN-EN 60099-4:2015-01 Beziskiernikowe ograniczniki przepiec z tlenkow metali do sieci pradu przemiennego / Spark-free metal oxide surge arresters for AC networks Wytrzymalosc na rozciaganie / Tensile Strength\nZakres: / Range: do 300 kN / up to 300 kN\nProba odpornosci na rozciaganie / Tensile Strength Test PN-EN 60099-4:2015-01","categories":["materials"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Tensile Strength","parameters_en":[{"name":"Range:","range":"do 300 kN / up to 300 kN"}],"search_en":"Spark-free metal oxide surge arresters for AC networks Tensile Strength Tensile Strength Test Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60099-4:2015-01","technique_en":"Tensile Strength Test","test_object_en":"Spark-free metal oxide surge arresters for AC networks","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"交流电网用无间隙金属氧化物避雷器 / Spark-free metal oxide surge arresters for AC networks 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60099-4:2015-01","parameters_zh":[{"name":"范围：","range":"do 300 kN / up to 300 kN"}],"test_object_zh":"交流电网用无间隙金属氧化物避雷器 / Spark-free metal oxide surge arresters for AC networks"},{"_id":"6a7d7594441eff5f156487d4","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Beziskiernikowe ograniczniki przepięć z tlenków metali do sieci prądu przemiennego / Spark-free metal oxide surge arresters for AC networks","methodology":"Wytrzymałość mechaniczna / Mechanical resistance","parameters":[{"name":"Zakres: / Range:","range":"do 20 kN / up to 20 kN"}],"technique":"Narażenia termomechaniczne / Thermomechanical stress","techniques":["Narażenia termomechaniczne / Thermomechanical stress"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość mechaniczna / Mechanical resistance\nZakres: / Range: do 20 kN / up to 20 kN\nNarażenia termomechaniczne / Thermomechanical stress","reference":"PN-EN 60099-4:2015-01","norm_bases":["PN-EN 60099-4:2015-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beziskiernikowe ograniczniki przepięć z tlenków metali do sieci prądu przemiennego / Spark-free metal oxide surge arresters for AC networks Wytrzymałość mechaniczna / Mechanical resistance\nZakres: / Range: do 20 kN / up to 20 kN\nNarażenia termomechaniczne / Thermomechanical stress PN-EN 60099-4:2015-01 Beziskiernikowe ograniczniki przepiec z tlenkow metali do sieci pradu przemiennego / Spark-free metal oxide surge arresters for AC networks Wytrzymalosc mechaniczna / Mechanical resistance\nZakres: / Range: do 20 kN / up to 20 kN\nNarazenia termomechaniczne / Thermomechanical stress PN-EN 60099-4:2015-01","categories":["materials"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Mechanical resistance","parameters_en":[{"name":"Range:","range":"do 20 kN / up to 20 kN"}],"search_en":"Spark-free metal oxide surge arresters for AC networks Mechanical resistance Thermomechanical stress Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60099-4:2015-01","technique_en":"Thermomechanical stress","test_object_en":"Spark-free metal oxide surge arresters for AC networks","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"交流电网用无间隙金属氧化物避雷器 / Spark-free metal oxide surge arresters for AC networks 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60099-4:2015-01","parameters_zh":[{"name":"范围：","range":"do 20 kN / up to 20 kN"}],"test_object_zh":"交流电网用无间隙金属氧化物避雷器 / Spark-free metal oxide surge arresters for AC networks"},{"_id":"6a7d7594441eff5f156487d5","lab_id":"69ad52a3de79e566650fb0fb","country":"PL","accr_number":"AB 067","accr_body":"PCA","test_object":"Beziskiernikowe ograniczniki przepięć z tlenków metali do sieci prądu przemiennego / Spark-free metal oxide surge arresters for AC networks","methodology":"Wytrzymałość elektryczna / Electrical Strength","parameters":[{"name":"Zakres: / Range:","range":"do 30 kV / up to 30 kV"}],"technique":"Starzenie w komorze solnej pod napięciem / Aging in a Live Salt Spray Chamber","techniques":["Starzenie w komorze solnej pod napięciem / Aging in a Live Salt Spray Chamber"],"computed":["Przedmiot badań / wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna / Electrical Strength\nZakres: / Range: do 30 kV / up to 30 kV\nStarzenie w komorze solnej pod napięciem / Aging in a Live Salt Spray Chamber","reference":"PN-EN 60099-4:2015-01","norm_bases":["PN-EN 60099-4:2015-01"],"lab_section":"Laboratorium Badawcze Materiałów Elektrotechnicznych; Zespół Badania Izolatorów; Electrotechnical Materials Testing Laboratory; Insulator Research Group","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beziskiernikowe ograniczniki przepięć z tlenków metali do sieci prądu przemiennego / Spark-free metal oxide surge arresters for AC networks Wytrzymałość elektryczna / Electrical Strength\nZakres: / Range: do 30 kV / up to 30 kV\nStarzenie w komorze solnej pod napięciem / Aging in a Live Salt Spray Chamber PN-EN 60099-4:2015-01 Beziskiernikowe ograniczniki przepiec z tlenkow metali do sieci pradu przemiennego / Spark-free metal oxide surge arresters for AC networks Wytrzymalosc elektryczna / Electrical Strength\nZakres: / Range: do 30 kV / up to 30 kV\nStarzenie w komorze solnej pod napieciem / Aging in a Live Salt Spray Chamber PN-EN 60099-4:2015-01","categories":["materials"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"lab_section_en":"Electrotechnical Materials Testing Laboratory; Insulator Research Group","methodology_en":"Electrical Strength","parameters_en":[{"name":"Range:","range":"do 30 kV / up to 30 kV"}],"search_en":"Spark-free metal oxide surge arresters for AC networks Electrical Strength Aging in a Live Salt Spray Chamber Electrotechnical Materials Testing Laboratory; Insulator Research Group Range: Material / product tested Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60099-4:2015-01","technique_en":"Aging in a Live Salt Spray Chamber","test_object_en":"Spark-free metal oxide surge arresters for AC networks","lab_section_zh":"电工材料检测实验室；绝缘子研究组","search_zh":"交流电网用无间隙金属氧化物避雷器 / Spark-free metal oxide surge arresters for AC networks 电工材料检测实验室；绝缘子研究组 范围： PN-EN 60099-4:2015-01","parameters_zh":[{"name":"范围：","range":"do 30 kV / up to 30 kV"}],"test_object_zh":"交流电网用无间隙金属氧化物避雷器 / Spark-free metal oxide surge arresters for AC networks"}],"has_pdf":true}