🇵🇱 INSTYTUT NAFTY I GAZU – PAŃSTWOWY INSTYTUT BADAWCZY PL

PCA AB 041 • Kraków, Poland • 493 methods

Petrochemistry & fuelsWater & wastewaterMaterials & polymersMetrology & calibrationEnvironmentConstructionElectronics & EMC

INSTYTUT NAFTY I GAZU – PAŃSTWOWY INSTYTUT BADAWCZY is a laboratory accredited by PCA under number AB 041 (Kraków, Poland). Its accreditation scope covers 493 test methods in the following areas: Petrochemistry & fuels, Water & wastewater, Materials & polymers, Metrology & calibration. Test objects include: Residential solid fuel burning appliances - Cookers, Residential solid fuel burning appliances, Residential solid fuel burning appliances - Roomheaters, inset appl…, Residential solid fuel burning appliances - Inset appliances, inclu…. Most frequently used techniques: Method: gravimetric, Chemiluminescence method; FID method, NDIR method; Method: PMD- paramagnetic; Electrochemical method.

At a glance

  • Accreditation number: PCA AB 041
  • Methods in scope: 493
  • Types of test objects: 80
  • Techniques used: 31
  • City: Kraków, Poland
Accreditation number
AB 041
Accreditation body
PCA
Address
ul. Lubicz 25a, 31-503 Kraków, ZESPÓŁ LABORATORIÓW BADAWCZYCH, SIECI, INSTALACJI I URZĄDZEŃ GAZOWYCH, ul. Bagrowa 1, 30-733 Kraków
City
Kraków, Poland

What this laboratory tests (80)

Analytical techniques used (31)

Laboratory sections (8)

Laboratory locations

Accreditation scope — test methods (493)

No. Test object Methodology / Parameters Technique Reference document
Climate and Resources Protection Laboratory (GE-1)
1 Refinery gas, natural gas, biogas, gas mixtures Gross calorific value, Net calorific value, Density, relative density, Wobbe index Calculation method based on gas composition PN-EN ISO 6976:2008
2 Natural gas, biogas, gas mixtures E Gas sampling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN ISO 10715
3 Natural gas, biogas, gas mixtures E Concentration of C1 – C5, C6+ hydrocarbons
methane (0,0001 – 100) % (mol/mol) ethane (0,0001 – 20) % (mol/mol) propane (0,0001 – 5) % (mol/mol) butanes (0,0001 – 1) % (mol/mol) pentanes (0,0001 – 0,5) % (mol/mol) C6+ (0,0001 – 1) % (mol/mol) N2 and CO2 concentration N2 (0,005 – 80) % (mol/mol) CO2 (0,005 – 80) % (mol/mol)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Gas chromatography with thermal conductivity detection (GC-TCD) PN-EN ISO 6974-5 03/GE-1/22
4 Natural gas, biogas, gas mixtures E Gross calorific value, Net calorific value, Density, relative density, Wobbe index
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Calculation method based on gas composition PN-EN ISO 6976
5 Natural gas, biogas, gas mixtures E Concentration of aliphatic hydrocarbons C6 – C12
hexanes (0,0001 – 0,5) % (mol/mol) heptanes (0,0001 – 0,5) % (mol/mol) octanes (0,0001 – 0,2) % (mol/mol) nonanes (0,0001 – 0,1) % (mol/mol) hydrocarbons higher than nonanes Range (0,0001 – 0,01) % (mol/mol)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Gas chromatography with flame ionization detection (GC-FID) 02/GE-1/22
6 Natural gas, biogas, gas mixtures E Concentration of sulphur compounds
Hydrogen sulfide Range (0,00001 – 0,05) % (mol/mol) methyl mercaptan (0,00001 – 0,05) % (mol/mol) ethyl mercaptan (0,00001 – 0,05) % (mol/mol) propyl mercaptan (0,00001 – 0,05) % (mol/mol) butyl mercaptan (0,00001 – 0,05) % (mol/mol) COS (0,00001 – 0,05) % (mol/mol) CS2 (0,00001 – 0,05) % (mol/mol) dimethyl sulphide (0,00001 – 0,05) % (mol/mol) dimethyl disulphide (0,00001 – 0,05) % (mol/mol) methyl ethyl sulphide (0,00001 – 0,05) % (mol/mol) diethyl sulphide (0,00001 – 0,05) % (mol/mol) diethyl disulphide (0,00001 – 0,05) % (mol/mol) dipropyl sulphide (0,00001 – 0,05) % (mol/mol)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Gas chromatography with flame photometric detection (GC-FPD) 01/GE-1/22 | PN-EN ISO 19739
7 Natural gas, gas mixtures, air E Water dew point
Range (-30 – +20) °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Method with a capacitive sensor 05/GE-1/22
8 Refinery gas, natural gas, gas mixtures E Concentration of C1 – C5, C6+ hydrocarbons
methane (0,001 – 100) % (mol/mol) ethane (0,001 – 100) % (mol/mol) ethene (0,001 – 100) % (mol/mol) propane (0,001 – 100) % (mol/mol) propene (0,001 – 100) % (mol/mol) butanes (0,001 – 100) % (mol/mol) butenes (0,001 – 100) % (mol/mol) 1,3 butadiene Range (0,001 – 100) % (mol/mol) pentanes (0,001 – 0,5) % (mol/mol) C6+ (0,001 – 5) % (mol/mol)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
04/GE-1/22
9 Refinery gas, natural gas, gas mixtures E N2, CO2, He, H2, O2, CO concentration
N2 (0,005 – 100) % (mol/mol) CO2 (0,005 – 100) % (mol/mol) He (0,005 – 100) % (mol/mol) H2 (0,005 – 100) % (mol/mol) O2 (0,005 – 100) % (mol/mol) CO (0,005 – 100) % (mol/mol)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Gas chromatography with thermal conductivity and flame ionization detection (GC-TCD, FID) 04/GE-1/22
10 Refinery gas, natural gas, gas mixtures E Gross calorific value, Net calorific value, Density, relative density, Wobbe index
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Calculation method based on gas composition PN-EN ISO 6976
Flow Metrology Laboratory (GM-1)
11 Diaphragm gas meters Errors of indication, pressure loss Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. 2008 nr 18 poz. 115)
12 Connecting components for gas installations Linear geometric dimensions PN-79/M-54840 p.4.3.2
13 Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters Metrological properties
indication error metrological reproducibility metrological repeatability durability effect of vibration drop resistance Volume flow range: (0,015 – 1 000) m3/h Maximum nominal diameter: DNmax = 200 mm Temperature range: (-40 – +70) °C
OIML R 137-1&2:2012 p.12.6.1; 12.6.2; 12.6.3; 12.6.9; 12.6.13; A.5.1; A.5.2
14 Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters Effect of temperature on metrological properties, Volume flow rate range: (0,015 – 160) m3/h, Temperature range: (-40 – +70) °C, Maximum nominal diameter: DNmax = 80 mm OIML R 137-1&2:2012 p. 12.6.7;
15 Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters Enclosure tightness, Maximum working pressure: 20 bar OIML R 137-1&2:2012 p. 6.1.2
16 Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters Design features
design dimensions of the counter components checking of the cyclic volume checking of the pulse value of the pulse transmitter increase in the indication of the control element
OIML R 137-1&2:2012, 6.3.4; 6.4.2; 6.4.3; 6.4.5
17 Diaphragm, turbine and rotary gas meters equipped with electronic devices (index units), Ultrasonic and thermal mass gas meters Operational tests – battery power supply
low voltage from the internal battery Volume flow range: (0,015 – 1 000) m3/h Maximum nominal diameter: DNmax = 200 mm
OIML R 137-1&2:2012 p.A.8
18 Diaphragm, turbine, rotary and ultrasonic gas meters Climatic environments:
resistance to moisture effect of vibration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 16314:2013-11E 4.9.2.2 b) 4.9.5
19 Diaphragm, turbine, rotary and ultrasonic gas meters Immunity to electromagnetic disturbances:
permanent magnetic field electrostatic discharge
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 16314:2013-11E 4.12.2 4.12.3
20 Diaphragm, turbine, rotary and ultrasonic gas meters Resistance to mishandling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 16314:2013-11E p. 4.14
21 Diaphragm, turbine, rotary and ultrasonic gas meters Storage temperature resistance, Temperature range: (-40 – +70) °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 16314:2013-11E p.4.15
22 Diaphragm, turbine, rotary and ultrasonic gas meters Ageing test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 16314:2013-11E p. 4.16
23 Diaphragm, turbine, rotary and ultrasonic gas meters Power supply system:
battery replacement voltage interruptions operating voltage
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 16314:2013-11E 6.5 6.7 6.8
24 Diaphragm, turbine, rotary and ultrasonic gas meters Additional functionalities
metrological influence valve durability resistance of the valve to contaminants in the gas non-volatile memory durability of the electronic counter
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 16314:2013-11E 7.4; 7.13.4.8 7.13.4.9 7.18.3; C.5 C.9
25 Diaphragm gas meters Durability (method with cyclic flow variations), Volume flow rate range: (0,015 – 10) m3/h, Temperature range: (-25 – +55) °C PB GM-08C wydanie 1 z dnia 20.03.2017
26 Turbine and rotary gas meters Metrological properties
resistance to the mounting position of the gas meter checking of the output shafts Volume flow rate range: (0,015 – 1 000) m3/h Maximum nominal diameter: DNmax = 200 mm
OIML R 137-1&2:2012 p. 12.6.4 12.6.10
27 Turbine, rotary and ultrasonic gas meters
resistance to flow direction Volume flow range: (0,015 – 1 000) m3/h Maximum nominal diameter: DNmax = 200 mm
OIML R 137-1&2:2012 p. 12.6.5
28 Turbine, ultrasonic and thermal mass gas meters Metrological properties
resistance to flow disturbances Volume flow range: (0,015 – 1 000) m3/h Maximum nominal diameter: DNmax = 200 mm
OIML R 137-1&2:2012 p. 12.6.8
29 Diaphragm, turbine and rotary gas meters Metrological properties
resistance to momentary overloads Volume flow range: (0,015 – 1 000) m3/h Maximum nominal diameter: DNmax = 200 mm
OIML R 137-1&2:2012 p. 12.6.11
30 Diaphragm, turbine and rotary gas meters equipped with electronic devices (index units), Ultrasonic and thermal mass gas meters Testing of the influence of environmental conditions:
testing of the effect of dry heat (without condensation) testing of the effect of low temperature Maximum nominal diameter: DNmax = 80 mm Temperature range (-40 – +70) °C testing of the effect of damp heat, steady state (no condensation) testing of the effect of water vapour condensation on the enclosure during cyclic temperature changes Maximum nominal diameter: DNmax = 80 mm Temperature range (-40 – +55) °C
OIML R 137-1&2:2012 p. A.4.1.1; A.4.1.2; A.4.2.1; A.4.2.2
31 Diaphragm, turbine and rotary gas meters equipped with electronic devices (index units), Ultrasonic and thermal mass gas meters Testing of the influence of electromagnetic factors:
testing of immunity to electrostatic discharge testing of immunity to electrical fast transient/burst Volume flow rate range: (0,015 – 1 000) m3/h Maximum nominal diameter: DNmax = 200 mm
OIML R 137-1&2:2012 p. A.6.2; A.6.3
32 Diaphragm and ultrasonic gas meters Gas valve and system:
valve operation valve capacity display of valve information pressure loss Range do 500 Pa Temperature range: (-40 – +70) °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Measurement method: direct - valve closing - valve opening - resistance to storage temperatures - valve resistance to a toluene/isooctane mixture - valve resistance to water vapour - resistance to ageing PN-EN 16314:2013-11E 7.13.3; 7.13.4.1.2; 7.13.4.2; 7.13.4.4; 7.13.4.5; 7.13.4.6; 7.13.4.7; D.3 D.4 D.5
33 Metallic, organic and anodic oxide coatings Resistance to salt fog PN-ISO 7253:2000 | PN-ISO 7253:2000/Ap1:2001
34 Ultrasonic gas meters Metrological properties:
maximum permissible errors relationship of indication errors for gas and air pressure loss metrological stability resistance to contaminants in the gas stream influence of installation zero flow reverse flow low flow high flow pulsating flow temperature sensitivity
PN-EN 14236:2019-01 5.3.2, 5.4, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11, 5.12, 5.13, 5.14
35 Ultrasonic gas meters Construction and materials:
resistance to internal pressures external tightness heat resistance arrangement of connections connection diameters resistance to torsional moment resistance to bending moment effect of vibration impact resistance resistance to improper handling scratch resistance of the coating adhesion of the protective coating impact resistance of the protective coating chemical resistance of the protective coating resistance to salt spray moisture resistance of the coating resistance to external humidity resistance to storage temperature resistance to toluene and isooctane vapours resistance to water vapour ageing
PN-EN 14236:2019-01 6.2.3 6.2.4 6.2.5 6.2.6.1 6.2.6.2 6.2.6.3 6.2.6.4 6.2.7 6.2.8 6.2.9 6.3.2.1, 6.4.1 6.3.2.2, 6.3.4.1 6.3.2.3, 6.3.4.2 6.3.2.4, 6.3.3.1, 6.3.4.3, 6.3.5.1 6.3.2.5, 6.3.3.2 6.3.2.6, 6.3.3.3, 6.3.4.4, 6.3.5.2, 6.4.2 6.8 6.10 6.11 6.12 6.13
36 Ultrasonic gas meters Optional properties:
properties of the pressure gauge connector resistance to high ambient temperature checking of the thermal shut-off valve checking of the gas meter with temperature corrector
PN-EN 14236:2019-01 7.1, 7.2, 7.2.3, 7.3 (Załącznik C)
37 Ultrasonic gas meters Design features of the index:
checking the operation of the display checking the operation of the segment display checking the operation of non-volatile memory
PN-EN 14236:2019-01 8.2, 8.3, 8.4
38 Ultrasonic gas meters Battery power supply test
battery replacement voltage interruptions minimum operating voltage
PN-EN 14236:2019-01 12.1, 12.2, 12.3
39 Diaphragm gas meters E Errors of indication, pressure loss, starting flow rate, metrological repeatability, cyclic volume, overload flow rate, influence of other devices, reverse flow, Flow rate range: (0,015 – 160) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
40 Diaphragm gas meters E Resistance to internal pressure
Maximum pressure 200 kPa
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
41 Diaphragm gas meters E Resistance of the connection spigots to torsional moment
Maximum pressure 50 kPa Load range (0 – 170) Nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
42 Diaphragm gas meters E Orientation of the connection ports, dimensions of threads and flanges
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
43 Diaphragm gas meters E Resistance of the connection spigots to bending moment Maximum working pressure: 100 kPa
Load range (0 – 60) Nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
44 Diaphragm gas meters E Durability, Volume flow rate range: (0,015 – 160) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
45 Diaphragm gas meters E Resistance to mishandling, Maximum working pressure: 100 kPa, Volume flow range: (0,015 – 160) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
46 Diaphragm gas meters E Effect of temperature on indication errors Maximum working pressure: 100 kPa
Temperature range (-40 – +70) °C Volume flow rate range: (0,015 – 100) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
47 Diaphragm gas meters E Ageing
Maximum temperature 70 °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
48 Diaphragm gas meters E Effect of vibration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
49 Diaphragm gas meters E Resistance of the diaphragms and internal parts of the gas meter to water vapour, Maximum relative humidity: 85 %, Volume flow range: (0,015 – 160) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
50 Diaphragm gas meters E Resistance of the diaphragms and internal parts of the diaphragm gas meter to toluene/isooctane vapours, Volume flow range: (0,015 – 100) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
51 Diaphragm gas meters E Scratch resistance of the protective coating
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359 | PN-EN ISO 1518-1
52 Diaphragm gas meters E Chemical resistance of the gas meter protective coating to external corrosion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359 | PN-EN ISO 2812-1
53 Diaphragm gas meters E Chemical resistance of the gas meter protective coating to internal corrosion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359 | PN-EN ISO 2812-1
54 Diaphragm gas meters E Design features of the index and impact resistance of the window and the housing of the gas meter index
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
55 Diaphragm gas meters E Resistance to neutral salt spray
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
56 Diaphragm gas meters E Resistance to external and internal corrosion with the use of humidity, Continuous condensation
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359 | PN-EN ISO 6270-1
57 Diaphragm gas meters E Resistance to environment and humidity, Volume flow range: (0,015 – 160) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359 | PN-EN ISO 6270-1
58 Diaphragm gas meters E Effect of neodymium magnets on indication errors, pressure loss, Volume flow rate range: (0,015 – 160) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PB GM-01
59 Diaphragm gas meters E Thread dimensions
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN ISO 228-1
60 Diaphragm gas meters with built-in temperature conversion device E Errors of indication at constant temperature
Temperature range (-40 – +70) °C Volume flow rate range: (0,015 – 100) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
61 Diaphragm gas meters with built-in temperature conversion device E Durability, Volume flow rate range: (0,015 – 160) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
62 Diaphragm gas meters with built-in temperature conversion device E Errors of indication at various ambient and gas temperatures
Temperature range (-40 – +70) °C Volume flow rate range: (0,015 – 100) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
63 Diaphragm gas meters, gaskets for diaphragm gas meters, gas meter cabinets E Resistance of gas meters to storage temperature Resistance of seals and cabinets to environmental conditions Volume flow range: (0,015 – 160) m3/h,
Temperature range (-70 – +70) °C Maximum dimensions of the object: (650x650x700) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
64 Diaphragm gas meters, gaskets for diaphragm gas meters, connectors for diaphragm gas meters, other gas installation components E Resistance to high ambient temperature
Range of the volume flow rate under normal conditions: (0,014 – 0,9) m3/h Maximum temperature 650 °C Maximum dimensions of the object: (520x450x650) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359 | PN-EN 1775
65 Diaphragm gas meters, connecting components for gas installations E External tightness, Maximum working pressure: 100 kPa
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
66 Diaphragm gas meters, gas meter cabinets E Impact resistance, Maximum working pressure: 100 kPa, Volume flow range: (0,015 – 160) m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1359
67 Turbine gas meters E Diameter of connections and dimensions
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12261 p.4
68 Turbine gas meters E Metrological properties:
indication error metrological repeatability linearity resistance to the mounting position of the gas meter resistance to momentary overload resistance to installation conditions pressure loss Volume flow rate range: (0,015 – 1 000) m3/h Maximum nominal diameter: DNmax = 200 mm Temperature range (-40 – +70) °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12261 p. 5.2.1, 5.2.2, 5.2.3, 5.2.5, 5.2.6, 5.2.8, Załącznik B, 5.2.9
69 Turbine gas meters E
resistance to temperature Volume flow rate range: (0,015 – 400) m3/h Maximum nominal diameter: DNmax = 80 mm Temperature range (-40 – +70) °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12261 p. 5.2.7
70 Turbine gas meters E Design features:
external tightness (pressure maximum 20 bar) impact strength of the counter window resistance to transport and storage resistance to external corrosion scratch resistance adhesion of the protective coating resistance to salt spray exposure characteristics of the pressure impulse holes dimensions of the pressure impulse holes design dimensions of the temperature measurement openings effectiveness of the gas meter lubrication system
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12261 p.6.2.3, 6.2.5, 6.2.6, 6.3.3, 6.3.3.1, 6.3.3.2, 6.3.3.3, 6.6.1, 6.6.1.1, 6.6.1.2, 6.6.2, 6.7
71 Turbine gas meters E Gas meter outputs
legibility of counter readings frequency of pulse transmitters resistance of voltage-free contacts design features of the checking element
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12261 p.7.2.3, 7.3.1, 7.3.2.2, 7.5
72 Rotary gas meters E Metrological properties:
indication error pressure loss metrological repeatability Volume flow range: (0,015 – 1000) m3/h Maximum nominal diameter: DNmax = 200 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12480
73 Rotary gas meters E Construction and materials:
resistance to external corrosion scratch resistance adhesion of the protective coating resistance to the rate of pressure change external tightness resistance to overload dimensions of the gas meter connections dimensions of the pressure impulse holes dimensions of the temperature openings resistance to transport and storage resistance to high temperature Maximum object dimensions: (520x450x650) mm Maximum temperature 650 °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12480
74 Rotary gas meters E
resistance to temperature Volume flow rate range: (0,015 – 400) m3/h Maximum nominal diameter: DNmax = 80 mm Temperature range (-40 – +70) °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12480
75 Rotary gas meters E Gas meter outputs
design features of the counter and the checking element (number of digits, scale interval, scale interval length, angle of rotation) design features of the counter window impact resistance of the counter window stiffness of the counter window frequency of pulse transmitters resistance of voltage-free contacts
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12480
76 Rotary gas meters E Durability, Maximum volume flow rate: 1000 m3/h
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12480
77 Metallic, organic and anodic oxide coatings E Resistance to salt fog
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN ISO 9227
78 Coatings, coating systems and materials resistant and non-resistant to corrosion E Humidity resistance, Continuous condensation
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN ISO 6270-1
79 Gas volume converters, pressure transducers, temperature transducers E Accuracy of indication under reference conditions
Temperature range (-40 – +125) °C Pressure range (0,4 – 135) bar abs
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A2
80 Gas volume converters, pressure transducers, temperature transducers E Effect of ambient temperature on metrological properties
Temperature range (-70 – +70) °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A3 | PN-EN 60068-2-1 | PN-EN 60068-2-2 | PN-EN 60068-3-1
81 Gas volume converters, pressure transducers, temperature transducers E Effect of steady-state damp heat on metrological properties
Temperature range (-40 – +55) °C Rel. humidity (10 – 98) %
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A4 | PN-EN 60068-2-78
82 Gas volume converters, pressure transducers, temperature transducers E Effect of cyclic damp heat on metrological properties
Temperature range (-40 – +55) °C Rel. humidity (10 – 98) %
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A5 | PN-EN 60068-2-30
83 Gas volume converters, pressure transducers, temperature transducers E Effect of variations in the electrical supply on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A6 | PN-EN 61000-4:11
84 Gas volume converters, pressure transducers, temperature transducers E Effect of short-time power reductions on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A7
85 Gas volume converters, pressure transducers, temperature transducers E Effect of electrical fast transients/bursts on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A8
86 Gas volume converters, pressure transducers, temperature transducers E Effect of electrostatic discharges on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A10
87 Gas volume converters, pressure transducers, temperature transducers E Effect of vibration on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A12
88 Gas volume converters, pressure transducers, temperature transducers E Effect of mechanical shocks on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A13 | PN-EN 60068-2-31
89 Gas volume converters, pressure transducers, temperature transducers E Durability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A15
90 Gas volume converters, pressure transducers, temperature transducers E Operation of the alarms
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A16
91 Gas volume converters, pressure transducers, temperature transducers E Metrological repeatability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A17
92 Gas volume converters, pressure transducers, temperature transducers E Effect of electromagnetic fields on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p. A9
93 Gas volume converters, pressure transducers, temperature transducers E Effect of conducted disturbances induced by radio-frequency fields on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p. A9
94 Gas volume converters, pressure transducers, temperature transducers E Effect of voltage dips, short interruptions and voltage variations (DC input) on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p. A18
95 Gas volume converters, pressure transducers, temperature transducers E Effect of shocks on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p. A19
96 Gas volume converters, pressure transducers, temperature transducers E Effect of power-frequency magnetic fields on metrological properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p. A20
97 Gas volume converters, pressure transducers E Resistance to pressure loading
Pressure range (0,4 – 135) bar abs
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A11
98 Gas volume converters, pressure transducers E Mechanical strength under pressure loading
Pressure range (0,4 – 135) bar abs
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.A14
99 Gas volume converters E Design and performance characteristics and properties:
accuracy durability operation of alarms repeatability resistance to: ambient temperature Temperature range (-40 – +70) °C damp heat steady state damp heat cyclic Temperature range (-40 – +70) °C rel. humidity (10 – 98) % short-term supply voltage dips electrical fast transient/burst electrostatic discharge pressure overload effect of vibration impacts pressure overload (mechanical) Pressure range (0,4 – 135) bar abs
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.9.1, 9,2
100 Platinum resistance thermometer sensors E Resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 + p.C.7.2 | PN-EN 60751
101 Platinum resistance thermometer sensors E Thermal response time, Self-heating coefficient, Immersion depth
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 Załącznik C | PN-EN 60751
102 Pressure transmitters E Immunity to variations in the electrical power supply
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 61000-4-11 | PN-EN 12405-1 p.B4
103 Pressure transmitters E Effect of short-duration voltage dips
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 61000-4-11 | PN-EN 12405-1 p.B4
104 Pressure transmitters E Effect of electrical fast transient bursts
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.B4
105 Pressure transmitters E Effect of electrostatic discharges
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.B4
106 Pressure transmitters E Design and performance characteristics and properties:
accuracy durability operation of alarms repeatability resistance to ambient temperature Temperature range (-40 – +70) °C damp heat steady state damp heat cyclic Temperature range: (-40 – +55) °C Rel. humidity (10 – 98) % short-term supply voltage dips electrical fast transient/burst electrostatic discharge pressure overload effect of vibration impacts pressure overload (mechanical) Pressure range (0,4 – 135) bar abs
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1
107 Temperature transmitters E Immunity to variations in the electrical power supply
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 61000-4-11 | PN-EN 12405-1 p.D4
108 Temperature transmitters E Effect of short-duration voltage dips
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 61000-4-11 | PN-EN 12405-1 p.D4
109 Temperature transmitters E Effect of electrical fast transient bursts
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.D4
110 Temperature transmitters E Effect of electrostatic discharges
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1 p.D4
111 Temperature transmitters E Design properties and performance characteristics:
accuracy resistance to ambient temperature Temperature range (-40 – +70) °C damp heat steady state damp heat cyclic Temperature range (-40 – +55) °C, Rel. humidity (10 – 98) % short-term supply voltage dips electrical fast transient/burst electrostatic discharge effect of vibration impacts durability operation of alarms repeatability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12405-1
112 Ball valves for gas installations in buildings E Resistance to high ambient temperature
Range of the leakage volume flow rate under normal conditions: (0,014 – 0,9) m3/h Maximum temperature 650 °C Maximum dimensions of the object: (520x450x650) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 1775 Procedura B „N”
113 Ball valves for gas installations in buildings E Dimensions of connection threads
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 10226-1 „N” | PN-EN ISO 228-1 „N”
Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)
114 Ball valves for gas installations in buildings Tightness in the temperature classes declared by the manufacturer
Range do 20 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 331:2005P p.7.2 | PN-EN 331:2005/A1:2011E p.7.2
115 Ball valves for gas installations in buildings Driving torque
Range do 40 Nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 331:2005P p.7.4 | PN-EN 331:2005/A1:2011E p.7.4
116 Ball valves for gas installations in buildings Durability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 331:2005P p.7.6 | PN-EN 331:2005/A1:2011E p.7.6
117 Ball valves for gas installations in buildings Flexural and torsional strength
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 331:2005P p.7.5 | PN-EN 331:2005/A1:2011E p.7.5
118 Ball valves for gas installations in buildings Nominal flux
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 331:2005P p.7.3 | PN-EN 331:2005/A1:2011E p.7.3
119 Ball valves for gas installations in buildings Sealing angle
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 331:2005P p.7.7 | PN-EN 331:2005/A1:2011E p.7.7
120 Ball valves for gas installations in buildings Humidity resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 331:2005P p.7.6.5 | PN-EN 331:2005/A1:2011E p.7.6.5
121 Ball valves for gas installations in buildings Strength of stops
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 331:2005P p.7.8 | PN-EN 331:2005/A1:2011E p.7.8
122 Protective plastics coatings on steel pipes and fittings Mass (MFR) melt flow rate of the plastic PN-EN ISO 1133:2006
123 Shut-off valves for gas and water supply networks E Driving torque
Range do 800 Nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 13774 p.5.5
124 Shut-off valves for gas and water supply networks E Strength
Range do 150 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12266-1A2 | PN-EN 1074-1 p.5.1
125 Shut-off valves for gas and water supply networks E External tightness
Range do 120 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12266-1, A.3 | PN-EN 1074-1 p.5.2
126 Shut-off valves for gas and water supply networks E Tightness of the closing
Range do 6 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12266-1, A.4 | PN-EN 1074-1 p.5.2
127 Shut-off valves for gas and water supply networks E Durability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 13774 p.5.5 | PN-EN 1074-1 p.5.5
128 Fittings for water supply, central heating and solar installations E Hydraulic strength in the temperature classes declared by the manufacturer
Range do 60 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 13828 | PN-M-75002
129 Fittings for water supply, central heating and solar installations E Tightness in the temperature classes declared by the manufacturer
Range do 60 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 13828 p.7.4.1 | PN-M-75002 p 6.2.5
130 Fittings for water supply, central heating and solar installations E Driving torque
Range do 65 Nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 13828 p.7.1
131 Fittings for water supply, central heating and solar installations E Durability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 13828 | PN-EN 1213
132 Fittings for water supply, central heating and solar installations E Verification of marking
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-M-75002
133 Fittings for water supply, central heating and solar installations E External appearance, construction, assembly and disassembly (thread size – gauge method)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-M-75002
134 Fittings for water supply, central heating and solar installations E Operation (driving torque)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-M-75002
135 Fittings for water supply, central heating and solar installations E Flow capacity of fittings (up to DN50)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-M-75002
136 Fittings for water supply, central heating and solar installations E Torsional strength (Range up to 1000 Nm)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1213 | PN-EN 13828
137 Fittings for water supply, central heating and solar installations E Flexural strength (Range up to 5 kN)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1213 | PN-EN 13828
138 Fittings for gas installations E External tightness in the temperature classes declared by the manufacturer
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12266-1, załącznik A3
139 Fittings for gas installations E Strength in the temperature classes declared by the manufacturer
Range do 8 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12266-1, załącznik A2
140 Sanitary tapware, Mechanical mixing valves E Resistance to internal pressure
Range do 25 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 817
141 Sanitary tapware, Mechanical mixing valves E Tightness:
Range do 16 bar before the closing assembly and tightness of the closure closures against cross-flow between hot and cold water of the battery behind the locking assembly manual switch self-returning switch
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 817
142 Sanitary tapware, Mechanical mixing valves E Hydraulic properties:
for temperature do 90 °C for pressure: do 5 bar flow measurement. Determination of the flow class determination of sensitivity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 817
143 Sanitary tapware, Mechanical mixing valves E Resistance to mechanical wear:
testing of the resistance of the control element to mechanical wear testing of the switch for mechanical wear testing of the swivel spout for mechanical wear
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 817
144 Sanitary tapware, Mechanical mixing valves E Mechanical properties:
torsional resistance of the adjustment components
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 817
145 Sanitary tapware (showers, shower hoses) E Tightness of showers
Range do 5 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1112
146 Sanitary tapware (showers, shower hoses) E Hydraulic properties:
flow measurement. Determination of the flow class
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1112 | PN-EN 1113
147 Sanitary tapware (showers, shower hoses) E Mechanical properties:
tensile strength of the hose bending strength of the spray hose mechanical strength of the spray outlet resistance of the spray outlet and hose to temperature changes pressure strength of the hose at elevated temperature
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1112 | PN-EN 1113
148 Protective plastic coatings on steel pipes and fittings E Resistance of coating materials and coatings to ageing and thermal
Range do 200 ± 2 °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12068 | PN-EN 10290 | PN-EN ISO 21809-1
149 Protective plastic coatings on steel pipes and fittings E Thickness of coating materials and coatings
Range (0 – 15) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Inductive method PN-EN ISO 2808 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1
150 Protective plastic coatings on steel pipes and fittings E Strength properties of coating materials and coatings:
breaking load percentage elongation at break, Range do 20 kN Tests at temp. 23 ± 3 °C Tensile test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN ISO 527-1 | PN-EN ISO 527-2 | PN-EN ISO 527-3 | PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2
151 Protective plastic coatings on steel pipes and fittings E Tightness (absence of pores) of the coating
Range do 30 kV Direct voltage breakdown test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2
152 Protective plastic coatings on steel pipes and fittings E Indentation resistance of the coating
Range (0 – 10) mm Indentation test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1
153 Protective plastic coatings on steel pipes and fittings E Impact resistance of the coating
Range of drop height 1,5 m Weight mass 1000 g, 2000 g
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Falling weight method PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1
154 Protective plastic coatings on steel pipes and fittings E Interlayer adhesion of the coating made of wrapping and heat-shrinkable material
Range do 20 kN Pull-off test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12068
155 Protective plastic coatings on steel pipes and fittings E Adhesion of the coating to the sub-coating surface: steel pipe, extruded PE coating, other working coating
Range do 20 kN Temperature 20 ± 3 °C Peel test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1
156 Protective plastic coatings on steel pipes and fittings E Resistance of the coating to slippage (shear) from the substrate surface: steel, extruded PE coating, another coating
working Shear test Range do 20 kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12068
157 Protective plastic coatings on steel pipes and fittings E Unit resistance of the coating
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN 10290
158 Protective plastic coatings on steel pipes and fittings E Mass (MFR) melt flow rate of the plastic
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN ISO 1133-1 | DIN 30670
159 Protective plastic coatings on steel pipes and fittings E Resistance of a damaged coating to under-film corrosion resulting from loss of adhesion to steel or coating disbonding under the influence of the cathodic polarisation current of the steel
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2
Plastics Laboratory (GP-3)
160 Thermoplastics pipes and fittings, Multilayer piping systems and fittings Resistance to cyclic temperature changes
temperature do 95 °C
Method using cyclic temperature action PN-EN 12293:2002
161 Non-cellular plastics, Pipes, fittings and other products made of non-cellular plastics E Density
Range (0,1 – 1) g/cm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Immersion method PN-EN ISO 1183-1
162 Thermoplastics, Pipes, fittings and other thermoplastic products E Melt mass-flow rate (MFR)
load 2,16 kg i 5 kg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Plastometric method PN-EN ISO 1133-1
163 Thermoplastic pipes E Tensile mechanical properties
elongation at fracture Load do 20 kN Elongation do 1200 % Static tensile test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN ISO 6259-1
164 Thermoplastics pipes, fittings and assemblies, Multilayer piping systems and fittings, PE/Metal joints, Domestic gas service connections E Resistance to internal pressure
diameter do 630 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Water-in-water and water-in-air method PN-EN ISO 1167-1
165 Plastics pipes, fittings and other products, Multilayer piping systems, PE/Metal joints, Domestic gas service connections E Dimensions
diameter wall thickness ovality length diameter 15 – 630 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Direct method PN-EN ISO 3126
166 Polyethylene pipes and fittings E Tensile strength of the butt-fused joint
Maximum load do 20 kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Static tensile test method ISO 13953
167 Thermoplastic pipes E Longitudinal shrinkage
temperature max 120 °C Wall thickness do 16 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Method using a heating chamber PN-EN ISO 2505
168 Polyethylene pipes E Circumferential shrinkage
Maximum diameter 630 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1555-2 pkt.9.3
169 Polyethylene pipes E Resistance to squeezing
diameter do 110 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Water-in-water and water-in-air method PN-EN 12106
170 Polyolefin pipes E Resistance to slow crack growth. Notch test
diameter from 63 mm do 315 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Method using hydrostatic pressure PN-EN ISO 13479
171 Polyethylene electrofusion fittings E Resistance to pull-off
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
ISO 13954 | ISO 13955 | ISO 13956
172 Polyethylene electrofusion (saddle) fittings E Impact resistance
Weight mass: do 5 kg Drop height do 2,5 m
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Falling weight method PN-EN 1716
173 Segmented fittings (tees), Polyethylene valves, Insulating joints, PE/Metal transition joints, Fittings with polyethylene ends, Domestic gas service connections E Resistance to axial forces
Max force 320 kN Tensile test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Procedura P-23
174 Polyethylene valves, Insulating joints, PE/Metal transition joints, Domestic gas service connections E External tightness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Air test method Procedura P-21
175 Plastics pipes and fittings, Multilayer piping systems and fittings E Tightness under internal pressure and bending
pressure (10 – 110) bar diameter: DN (32 – 160 mm)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Method using internal pressure PN-EN ISO 3503
176 Thermoplastic pipes and fittings, Multilayer pipe and fitting systems E Resistance to cyclic pressure changes
pressure pmax do 55 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Method using cyclic pressure action PN-EN ISO 19892
177 Thermoplastic pipes and fittings, Multilayer pipe and fitting systems E Tightness under negative pressure conditions
Pressure do -0,8 bar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Method using vacuum PN-EN ISO 13056
178 Polyethylene, pipes, fittings and other polyethylene products E Resistance to slow crack growth – strain hardening modulus (SHT)
force do 500 N Tensile test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
ISO 18488
179 Polyethylene pipes, fittings and other products E Resistance to slow crack growth under cyclic loading (CRB)
force do 3 kN Fatigue test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
ISO 18489
Gas and Heating Appliances Testing Laboratory (GU-1)
180 Appliances burning gaseous fuels used for cooking, heating, hot water production, refrigeration, lighting, washing or dish-washing and, where applicable, having a water temperature not exceeding 105 °C, forced draught burners and heating bodies to be equipped with such burners, (excluding industrial appliances), Safety devices, controlling devices or regulating devices and sub-assemblies marketed separately and designed to be incorporated into an appliance burning gaseous fuel or, when assembled, to constitute such an appliance, (excluding industrial appliances) Characteristics and properties for the assessment of operational safety:
functionality of fittings verification of materials mechanical stability condensation explosion hazard water penetration normal and abnormal supply power fluctuations risk of electric shock pressure resistance reliability of safety, control and regulating devices interaction of control and safety devices protection of components set by the manufacturer control and setting devices release of unburned gas leaks gas accumulation in the appliance and in the room ignition safety combustion quality and stability tightness of the flue gas system spillage of flue gases into the room in the event of draught disturbance heating temperatures of components Hygiene of components in contact with drinking water and food Rational energy consumption
PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002
181 Residential solid fuel burning appliances FUEL PARAMETERS: PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002
182 Residential solid fuel burning appliances
fuel mass (0,1 – 20) kg
PN-EN 16510-1:2023-06 p. A.4.2
183 Residential solid fuel burning appliances FLUE GAS PARAMETERS: PN-EN 16510-1:2023-06 p. A.4.2
184 Residential solid fuel burning appliances
temperature (0 – 600) °C
PN-EN 16510-1:2023-06 p. A.4.4.3
185 Residential solid fuel burning appliances
pressure (0,01 – 200) Pa;
PN-EN 16510-1:2023-06 p. A.2.3.4; A.4
186 Residential solid fuel burning appliances Concentrations of carbon dioxide, carbon monoxide, oxygen
CO2; (0,1 – 20) % CO; (0,001 – 0,5) % O2; (0,1 – 21) % O2; (0 – 21) % CO emission (calculated)
NDIR method; Method: PMD - paramagnetic; Electrochemical method PN-EN 16510-1:2023-06 p. A.4.4.2
187 Residential solid fuel burning appliances Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.
NO (0,5 – 200) ppm NOx (0,5 – 200) ppm OGC; (0,269 – 1288) mg org. C/m3 CO2 emission; NO, NO2, NOx, OGC (calculated)
Chemiluminescence method; FID method PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E
188 Residential solid fuel burning appliances AIR PARAMETERS: PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E
189 Residential solid fuel burning appliances
temperature (10 – 35) °C
PN-EN 16510-1:2023-06 p. A.4.4.3
190 Residential solid fuel burning appliances WATER PARAMETERS: PN-EN 16510-1:2023-06 p. A.4.4.3
191 Residential solid fuel burning appliances
temperature (0 – 100) °C
PN-EN 16510-1:2023-06 p. A.4.5.2
192 Residential solid fuel burning appliances
volume flow rate : (0,24 – 12) m3/h
PN-EN 16510-1:2023-06 p. A.4.5.2
193 Residential solid fuel burning appliances HEAT BALANCE (calculated): PN-EN 16510-1:2023-06 p. A.4.5.2
194 Residential solid fuel burning appliances
heat input from fuel (3 – 60) kW
PN-EN 16510-1:2023-06 p. A.6.2.2
195 Residential solid fuel burning appliances
stack loss (5 – 40) %
PN-EN 16510-1:2023-06 p. A.6.2.1.2
196 Residential solid fuel burning appliances
losses due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.6.2.1.3
197 Residential solid fuel burning appliances
loss due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.6.2.1.4
198 Residential solid fuel burning appliances
thermal efficiency (20 – 95) %
PN-EN 16510-1:2023-06 p. A.6.2.1
199 Residential solid fuel burning appliances
total heat output (3 – 50) kW
PN-EN 16510-1:2023-06 p. A.6.2.2
200 Residential solid fuel burning appliances
heat output of the water circuit (3 – 50) kW
PN-EN 16510-1:2023-06 p. A.6.2.3
201 Residential solid fuel burning appliances
heat output to the room (3 – 50) kW
PN-EN 16510-1:2023-06 p. A.6.2.4
202 Residential solid fuel burning appliances
flue gas mass flow (5 – 100) g/s
PN-EN 16510-1:2023-06 p. A.6.2.5
203 Residential solid fuel burning appliances
CO content (O2=13 %) (0,001 – 0,5) %
PN-EN 16510-1:2023-06 p. A.6.2.6
204 Residential solid fuel burning appliances TECHNICAL AND OPERATIONAL PARAMETERS: PN-EN 16510-1:2023-06 p. A.6.2.6
205 Residential solid fuel burning appliances
temperature of the measuring corner and the floor (0 – 200) °C temperature of the fuel hopper (0 – 200) °C temperature of handles (0 – 300) °C
PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10
206 Residential solid fuel burning appliances
tightness of the water space (0,1 – 0,6) MPa
PN-EN 16510-1:2023-06 p. A.4.10.6
207 Residential solid fuel burning appliances
thermal outlet safety device water temperature (0 – 120) °C water pressure (0,1 – 0,3) MPa
PN-EN 16510-1:2023-06 p. A.4.10.6
208 Residential solid fuel burning appliances
tightness (0,016 – 2,6) m3/h
PN-EN 16510-1:2023-06 p. A.4.11.2
209 Residential solid fuel burning appliances
tightness related to CO emission (calculated)
PN-EN 16510-1:2023-06 p. 5.9.1
210 Residential solid fuel burning appliances measurement of electrical energy consumption (1 – 1500) W, method: power transducers PN-EN 16510-1:2023-06 p. 6.11
211 Residential solid fuel burning appliances
temperature safety test
PN-EN 16510-1:2023-06 p. A.4.10.4
212 Residential solid fuel burning appliances
safety test under natural draught
PN-EN 16510-1:2023-06 p. A.4.10.5
213 Residential solid fuel burning appliances
operation of the safety temperature limiter (0 – 110) °C
PN-EN 16510-1:2023-06 p. A.4.10.7
214 Residential solid fuel burning appliances
loss of electrical power supply (0 – 110) °C
PN-EN 16510-1:2023-06 p. A.4.10.7
215 Residential solid fuel burning appliances
loss of heat dissipation (0 – 110) °C, (0 – 5) %CO
PN-EN 16510-1:2023-06 p. A.4.10.7
216 Residential solid fuel burning appliances
efficiency (calculated)
PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6
217 Residential solid fuel burning appliances Dust concentration in flue gases
Range (0,003 – 1) g/m3
Method: gravimetric PN-EN 16510-1:2023-06 Załącznik F
218 Residential solid fuel burning appliances - Roomheaters FUEL PARAMETERS: PN-EN 16510-1:2023-06 Załącznik F
219 Residential solid fuel burning appliances - Roomheaters
fuel mass (0,1 – 20) kg
PN-EN 16510-1:2023-06 p. A.4.2
220 Residential solid fuel burning appliances - Roomheaters FLUE GAS PARAMETERS: PN-EN 16510-1:2023-06 p. A.4.2
221 Residential solid fuel burning appliances - Roomheaters
temperature (0 – 600) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-1:2023-06 p.4.7.2, 4.7.3, 4.7.8 „N“
222 Residential solid fuel burning appliances - Roomheaters
pressure (0,01 – 200) Pa;
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“
223 Residential solid fuel burning appliances - Roomheaters Concentrations of carbon dioxide, carbon monoxide, oxygen
CO2; (0,1 – 20) % CO; (0,001 – 0,5) % O2; (0,1 – 21) % O2; (0 – 21) % CO emission (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
NDIR method; Method: PMD- paramagnetic; Electrochemical method PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“
224 Residential solid fuel burning appliances - Roomheaters Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.
NO (0,5 – 200) ppm NOx (0,5 – 200) ppm OGC; (0,269 –1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method; FID method PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“
225 Residential solid fuel burning appliances - Roomheaters AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“
226 Residential solid fuel burning appliances - Roomheaters
temperature (10 – 35) °C
PN-EN 16510-1:2023-06 p. A.4.4.3
227 Residential solid fuel burning appliances - Roomheaters WATER PARAMETERS: PN-EN 16510-1:2023-06 p. A.4.4.3
228 Residential solid fuel burning appliances - Roomheaters
temperature (0 – 100) °C
PN-EN 16510-1:2023-06 p. A.4.5.2
229 Residential solid fuel burning appliances - Roomheaters
volume flow rate : (0,24 – 12) m3/h
PN-EN 16510-1:2023-06 p. A.4.5.2
230 Residential solid fuel burning appliances - Roomheaters HEAT BALANCE (calculated): PN-EN 16510-1:2023-06 p. A.4.5.2
231 Residential solid fuel burning appliances - Roomheaters
heat input from fuel (3 – 60) kW
PN-EN 16510-1:2023-06 p. A.6.2.2
232 Residential solid fuel burning appliances - Roomheaters
stack loss (5 – 40) %
PN-EN 16510-1:2023-06 p. A.6.2.1.2
233 Residential solid fuel burning appliances - Roomheaters
losses due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.6.2.1.3
234 Residential solid fuel burning appliances - Roomheaters
loss due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.6.2.1.4
235 Residential solid fuel burning appliances - Roomheaters
thermal efficiency (20 – 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N”
236 Residential solid fuel burning appliances - Roomheaters
total heat output (3 – 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N”
237 Residential solid fuel burning appliances - Roomheaters
heat output of the water circuit (3 – 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N”
238 Residential solid fuel burning appliances - Roomheaters
heat output to the room (3 – 50) kW
PN-EN 16510-1:2023-06 p. A.6.2.4
239 Residential solid fuel burning appliances - Roomheaters
flue gas mass flow (5 – 100) g/s
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“
240 Residential solid fuel burning appliances - Roomheaters
CO content (O2=13 %) (0,001 – 0,5) %
PN-EN 16510-1:2023-06 p. A.6.2.6
241 Residential solid fuel burning appliances - Roomheaters TECHNICAL AND OPERATIONAL PARAMETERS: PN-EN 16510-1:2023-06 p. A.6.2.6
242 Residential solid fuel burning appliances - Roomheaters
temperature of the measuring corner and the floor (0 – 200) °C temperature of the fuel hopper (0 – 200) °C temperature of handles (0 – 300) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10 | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“
243 Residential solid fuel burning appliances - Roomheaters
tightness of the water space (0,1 – 0,6) MPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N”
244 Residential solid fuel burning appliances - Roomheaters
thermal outlet safety device water temperature (0 – 120) °C water pressure (0,1 – 0,3) MPa
PN-EN 16510-1:2023-06 p. A.4.10.7
245 Residential solid fuel burning appliances - Roomheaters
tightness (0,016 – 2,6) m3/h
PN-EN 16510-1:2023-06 p. A.4.11.2
246 Residential solid fuel burning appliances - Roomheaters
tightness related to CO emission (calculated)
PN-EN 16510-1:2023-06 p. 5.9.1
247 Residential solid fuel burning appliances - Roomheaters measurement of electrical energy consumption (1 – 1500) W, method: power transducers PN-EN 16510-1:2023-06 p. 6.11
248 Residential solid fuel burning appliances - Roomheaters
temperature safety test
PN-EN 16510-1:2023-06 p A.4.10.4
249 Residential solid fuel burning appliances - Roomheaters
safety test under natural draught
PN-EN 16510-1:2023-06 p A.4.10.5
250 Residential solid fuel burning appliances - Roomheaters
efficiency (calculated) seasonal space heating energy efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p . A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N”
251 Residential solid fuel burning appliances - Roomheaters Dust concentration in flue gases
Range (0,003 – 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Method: gravimetric PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”
252 Residential solid fuel burning appliances - Inset appliances, including open fires FUEL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”
253 Residential solid fuel burning appliances - Inset appliances, including open fires
fuel mass (0,1 – 20) kg
PN-EN 16510-1:2023-06 p. A.4.2
254 Residential solid fuel burning appliances - Inset appliances, including open fires FLUE GAS PARAMETERS: PN-EN 16510-1:2023-06 p. A.4.2
255 Residential solid fuel burning appliances - Inset appliances, including open fires
temperature (0 – 600) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N”
256 Residential solid fuel burning appliances - Inset appliances, including open fires
pressure (0,01 – 200) Pa;
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5 „N”
257 Residential solid fuel burning appliances - Inset appliances, including open fires Concentrations of carbon dioxide, carbon monoxide, oxygen
CO2; (0,1 – 20) % CO; (0,001 – 0,5) % O2; (0,1 – 21) % O2; (0 – 21) % CO emission (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
NDIR method; Method: PMD- paramagnetic; Electrochemical method PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“
258 Residential solid fuel burning appliances - Inset appliances, including open fires Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.
NO (0,5 – 200) ppm NOx (0,5 – 200) ppm OGC; (0,269 – 1288) mg org. C/m3 CO2 emission; NO, NO2, NOx, OGC (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method; FID method PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“
259 Residential solid fuel burning appliances - Inset appliances, including open fires AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“
260 Residential solid fuel burning appliances - Inset appliances, including open fires
temperature (10 – 35) °C
PN-EN 16510-1:2023-06 p. A.4.4.3
261 Residential solid fuel burning appliances - Inset appliances, including open fires WATER PARAMETERS: PN-EN 16510-1:2023-06 p. A.4.4.3
262 Residential solid fuel burning appliances - Inset appliances, including open fires
temperature (0 – 100) °C
PN-EN 16510-1:2023-06 p. A.4.5.2
263 Residential solid fuel burning appliances - Inset appliances, including open fires
volume flow rate : (0,24 – 12) m3/h
PN-EN 16510-1:2023-06 p. A.4.5.2
264 Residential solid fuel burning appliances - Inset appliances, including open fires HEAT BALANCE (calculated): PN-EN 16510-1:2023-06 p. A.4.5.2
265 Residential solid fuel burning appliances - Inset appliances, including open fires
heat input from fuel (3 – 60) kW
PN-EN 16510-1:2023-06 p. A.6.2.2
266 Residential solid fuel burning appliances - Inset appliances, including open fires
stack loss (5 – 40) %
PN-EN 16510-1:2023-06 p. A.6.2.1.2
267 Residential solid fuel burning appliances - Inset appliances, including open fires
losses due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.6.2.1.3
268 Residential solid fuel burning appliances - Inset appliances, including open fires
loss due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.6.2.1.4
269 Residential solid fuel burning appliances - Inset appliances, including open fires
thermal efficiency (20 – 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N”
270 Residential solid fuel burning appliances - Inset appliances, including open fires
total heat output (3 – 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N”
271 Residential solid fuel burning appliances - Inset appliances, including open fires
heat output of the water circuit (3 – 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N”
272 Residential solid fuel burning appliances - Inset appliances, including open fires
heat output to the room (3 – 50) kW
PN-EN 16510-1:2023-06 p. A.6.2.4
273 Residential solid fuel burning appliances - Inset appliances, including open fires
flue gas mass flow (5 – 100) g/s
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2018-08 p. A.6.2.5 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N”
274 Residential solid fuel burning appliances - Inset appliances, including open fires
CO content (O2=13 %) (0,001 – 0,5) %
PN-EN 16510-1:2023-06 p. A.6.2.6
275 Residential solid fuel burning appliances - Inset appliances, including open fires TECHNICAL AND OPERATIONAL PARAMETERS: PN-EN 16510-1:2023-06 p. A.6.2.6
276 Residential solid fuel burning appliances - Inset appliances, including open fires
temperature of the measuring corner and the floor (0 – 200) °C temperature of the fuel hopper (0 – 200) °C temperature of handles (0 – 300) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.7; A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N”
277 Residential solid fuel burning appliances - Inset appliances, including open fires
tightness of the water space (0,1 – 0,6) MPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N”
278 Residential solid fuel burning appliances - Inset appliances, including open fires
thermal outlet safety device water temperature (0 – 120) °C water pressure (0,1 – 0,3) MPa
PN-EN 16510-1:2023-06 p. A.4.10.7
279 Residential solid fuel burning appliances - Inset appliances, including open fires
tightness (0,016 – 2,6) m3/h
PN-EN 16510-1:2023-06 p. A.4.11.2
280 Residential solid fuel burning appliances - Inset appliances, including open fires
tightness related to CO emission (calculated)
PN-EN 16510-1:2023-06 p 5.9.1
281 Residential solid fuel burning appliances - Inset appliances, including open fires
measurement of electrical energy consumption (1 – 1500) W, method: power transducers
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”
282 Residential solid fuel burning appliances - Inset appliances, including open fires
temperature safety test
PN-EN 16510-1:2023-06 p. A.4.10.4
283 Residential solid fuel burning appliances - Inset appliances, including open fires
safety test under natural draught
PN-EN 16510-1:2023-06 p. A.4.10.5
284 Residential solid fuel burning appliances - Inset appliances, including open fires
efficiency (calculated) seasonal space heating energy efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N”
285 Residential solid fuel burning appliances - Inset appliances, including open fires Dust concentration in flue gases
Range (0,003 – 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Method: gravimetric PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”
286 Residential solid fuel burning appliances - Cookers FUEL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”
287 Residential solid fuel burning appliances - Cookers
fuel mass (0,1 – 20) kg
PN-EN 16510-1:2023-06 p. A.4.2
288 Residential solid fuel burning appliances - Cookers FLUE GAS PARAMETERS: PN-EN 16510-1:2023-06 p. A.4.2
289 Residential solid fuel burning appliances - Cookers
temperature (0 – 600) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.2, A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.2, 4.6.3 „N”
290 Residential solid fuel burning appliances - Cookers
pressure (0,01 – 200) Pa;
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.2; A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”
291 Residential solid fuel burning appliances - Cookers Concentrations of carbon dioxide, carbon monoxide, oxygen
CO2; (0,1 – 20) % CO; (0,001 – 0,5) % O2; (0,1 – 21) % O2; (0 – 21) % CO emission (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
NDIR method; Method: PMD- paramagnetic; Electrochemical method PN-EN 16510-1:2023-06 p. A.2.3; A.4.4.2 | PN-EN 16510-2-3:2023-06 p. 4.2 „N”
292 Residential solid fuel burning appliances - Cookers Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.
NO (0,5 – 200) ppm NOx (0,5 – 200) ppm OGC; (0,269 –1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method; FID method PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”
293 Residential solid fuel burning appliances - Cookers AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”
294 Residential solid fuel burning appliances - Cookers
temperature (10 – 35) °C
PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3
295 Residential solid fuel burning appliances - Cookers WATER PARAMETERS: PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3
296 Residential solid fuel burning appliances - Cookers
temperature (0 – 100) °C
PN-EN 16510-1:2023-06 p. A.2.5; A.4.5
297 Residential solid fuel burning appliances - Cookers
volume flow rate: (0,24 – 12) m3/h
PN-EN 16510-1:2023-06 p. A.2.5; A.4.5
298 Residential solid fuel burning appliances - Cookers HEAT BALANCE (calculated): PN-EN 16510-1:2023-06 p. A.2.5; A.4.5
299 Residential solid fuel burning appliances - Cookers
heat input from fuel (3 – 60) kW
PN-EN 16510-1:2023-06 p. A.4.5; A.4.8; A.4.9, A.6.2.2
300 Residential solid fuel burning appliances - Cookers
stack loss (5 – 40) %
PN-EN 16510-1:2023-06 p. A.4.4, A.6.2.1.2
301 Residential solid fuel burning appliances - Cookers
losses due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.3
302 Residential solid fuel burning appliances - Cookers
loss due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.4
303 Residential solid fuel burning appliances - Cookers
thermal efficiency (20 – 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”
304 Residential solid fuel burning appliances - Cookers
total heat output (3 – 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”
305 Residential solid fuel burning appliances - Cookers
heat output of the water circuit (3 – 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”
306 Residential solid fuel burning appliances - Cookers
heat output to the room (3 – 50) kW
PN-EN 16510-1:2023-06 p. A.6.2.4
307 Residential solid fuel burning appliances - Cookers
flue gas mass flow (5 – 100) g/s
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”
308 Residential solid fuel burning appliances - Cookers
CO content (O2=13 %) (0,001 – 0,5) %
PN-EN 16510-1:2023-06 p. A.6.2.6
309 Residential solid fuel burning appliances - Cookers TECHNICAL AND OPERATIONAL PARAMETERS: PN-EN 16510-1:2023-06 p. A.6.2.6
310 Residential solid fuel burning appliances - Cookers
temperature of the measuring corner and the floor (0 – 200) °C temperature of the fuel hopper (0 – 200) °C temperature of handles (0 – 300) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.7 | PN-EN 16510-2-3:2023-06 p. 5.5, 5.6 „N”
311 Residential solid fuel burning appliances - Cookers
tightness of the water space (0,1 – 0,6) MPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.3.3 „N”
312 Residential solid fuel burning appliances - Cookers
thermal outlet safety device water temperature (0 – 120) °C water pressure (0,1 – 0,3) MPa
PN-EN 16510:2023-06 p. A.4.10.7
313 Residential solid fuel burning appliances - Cookers
boiling, water temperature (0 – 100) °C
PN-EN 16510-1:2023-06
314 Residential solid fuel burning appliances - Cookers
baking, air temperature (0 – 300) °C
PN-EN 16510-1:2023-06
315 Residential solid fuel burning appliances - Cookers
tightness (0,016 – 2,6) m3/h
PN-EN 16510-1:2023-06 p. A.4.11.2
316 Residential solid fuel burning appliances - Cookers
testing of the oven shelf
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-3:2023-06 p. A.4.301.4 „N”
317 Residential solid fuel burning appliances - Cookers
testing of the oven door
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-3:2023-06 p. A.4.301.5 „N”
318 Residential solid fuel burning appliances - Cookers
tightness related to CO emission (calculated)
PN-EN 16510-1:2023-06 p. 5.9.1
319 Residential solid fuel burning appliances - Cookers
measurement of electrical energy consumption (1 – 1500) W, method: power transducers
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”
320 Residential solid fuel burning appliances - Cookers
temperature safety test
PN-EN 16510-1:2023-06 p. A.4.10.4
321 Residential solid fuel burning appliances - Cookers
safety test under natural draught
PN-EN 16510-1:2023-06 p. A.4.10.5
322 Residential solid fuel burning appliances - Cookers
efficiency (calculated) seasonal space heating energy efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1. | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”
323 Residential solid fuel burning appliances - Cookers Dust concentration in flue gases
Range (0,003 – 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Method: gravimetric PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”
324 Heating boilers for solid fuels up to 50 kW FUEL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”
325 Heating boilers for solid fuels up to 50 kW
fuel mass (0,1 – 20) kg
PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2
326 Heating boilers for solid fuels up to 50 kW FLUE GAS PARAMETERS: PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2
327 Heating boilers for solid fuels up to 50 kW
temperature (0 – 600) °C
PN-EN 12809:2002 p. A.2.3.2. | PN-EN 16510:2018-08 p. A.2.3.2
328 Heating boilers for solid fuels up to 50 kW
pressure (0,01 – 250) Pa
PN-EN 12809:2002 p. A.2.3.4; A4 | PN-EN 16510:2018-08 p. A.2.3.4; A.4
329 Heating boilers for solid fuels up to 50 kW Concentrations of carbon dioxide, carbon monoxide, oxygen
CO2; (0,1 – 20) % CO; (0,001 – 0,800) % O2; (0,1 – 21) % O2; (0 – 21) % CO emission (calculated)
NDIR method; Method: PMD- paramagnetic; Electrochemical method PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3 | PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3
330 Heating boilers for solid fuels up to 50 kW Concentrations of nitrogen monoxide, nitrogen dioxide, nitrogen oxides (NO, NO2, NOx), OGC.
NO (0,1 – 1993) ppm NO2 (0,1 – 232) ppm NOx (0,1 – 1993) ppm NO (0,5 – 190) ppm NOx (0,5 – 190) ppm OGC (0,269 – 1286) mg/m3 CO2; NO, NO2, NOx, OGC emission (calculated)
NDIR method; Chemiluminescence method; FID method PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E
331 Heating boilers for solid fuels up to 50 kW AIR PARAMETERS: PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E
332 Heating boilers for solid fuels up to 50 kW
temperature (10 – 35) °C
PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1
333 Heating boilers for solid fuels up to 50 kW WATER PARAMETERS: PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1
334 Heating boilers for solid fuels up to 50 kW
temperature (0 – 100) °C
PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5
335 Heating boilers for solid fuels up to 50 kW
volume flow rate : (0,09 – 12) m3/h
PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5
336 Heating boilers for solid fuels up to 50 kW HEAT BALANCE (calculated): PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5
337 Heating boilers for solid fuels up to 50 kW
heat input from fuel (5 – 100) kW
PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2
338 Heating boilers for solid fuels up to 50 kW
stack loss (5 – 40) %
PN-EN 12809:2002 p. A.6.2.1.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.2
339 Heating boilers for solid fuels up to 50 kW
losses due to incomplete combustion
PN-EN 12809:2002 p. A.6.2.1.2 | PN-EN 16510-1:2018-08 p.A.6.2.1.3
340 Heating boilers for solid fuels up to 50 kW
loss due to incomplete combustion
PN-EN 12809:2002 p. A.6.2.1.3 | PN-EN 16510-1:2018-08 p.A.6.2.1.4
341 Heating boilers for solid fuels up to 50 kW
thermal efficiency (20 – 95) %
PN-EN 12809:2002 p. A.6.2.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.1
342 Heating boilers for solid fuels up to 50 kW
total heat output (3 – 50) kW
PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2
343 Heating boilers for solid fuels up to 50 kW
heat output of the water circuit (3 – 50) kW
PN-EN 12809:2002 p. A.6.2.3 | PN-EN 16510-1:2018-08 p.A.6.2.3
344 Heating boilers for solid fuels up to 50 kW
flue gas mass flow (5 – 100) g/s
PN-EN 12809:2002 p. A.6.2.4 | PN-EN 16510-1:2018-08 p.A.6.2.4
345 Heating boilers for solid fuels up to 50 kW
heat output to the room (3 – 50) kW
PN-EN 12809:2002 p. A.6.2.5 | PN-EN 16510-1:2018-08 p.A.6.2.5
346 Heating boilers for solid fuels up to 50 kW
CO content (O2=13 %) (0,001 – 0,800 )%
PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6
347 Heating boilers for solid fuels up to 50 kW TECHNICAL AND OPERATIONAL PARAMETERS: PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6
348 Heating boilers for solid fuels up to 50 kW
temperature of the measuring corner and the floor (0 – 200) °C temperature of the fuel hopper (0 – 200) °C temperature of handles (0 – 200) °C
PN-EN 12809:2002 p. A.2; A.3 | PN-EN 16510-1:2018-08 p.A.2.; A.3
349 Heating boilers for solid fuels up to 50 kW
tightness of the water space (0,1 – 0,6) MPa
PN-EN 12809:2002 p. A.4.10 | PN-EN 16510-1:2018-08 p. A.4.10.5
350 Heating boilers for solid fuels up to 50 kW
tightness (0,016 – 2,6) m3/h
PN-EN 16510-1:2018-08 p. A.4.11.2
351 Heating boilers for solid fuels up to 50 kW Dust concentration in flue gases
Range (0,01 – 1) g/m3
Method: gravimetric PN-EN 16510-1:2018-08 Załącznik F
352 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding FUEL PARAMETERS: PN-EN 16510-1:2018-08 Załącznik F
353 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
fuel mass (0,1 – 20) kg
PN-EN 16510-1:2023-06 p. A.4.2
354 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding FLUE GAS PARAMETERS: PN-EN 16510-1:2023-06 p. A.4.2
355 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
temperature (0 – 600) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-6:2023-06 p. 4.7.2, 4.7.3 „N”
356 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
pressure (0,01 – 200) Pa;
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N”
357 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Concentrations of carbon dioxide, carbon monoxide, oxygen
CO2; (0,1 – 20) % CO; (0,001 – 0,5) % O2; (0,1 – 21) % O2; (0 – 21) % CO emission (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
NDIR method; Method: PMD- paramagnetic; Electrochemical method PN-EN 16510-2-6:2023-06 p. 4.3 „N”
358 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.
NO (0,5 – 200) ppm NOx (0,5 – 200) ppm OGC (0,269 – 1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method; FID method PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”
359 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”
360 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
temperature (10 – 35) °C
PN-EN 16510-1:2023-06 p. A.4.4.3
361 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding WATER PARAMETERS: PN-EN 16510-1:2023-06 p. A.4.4.3
362 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
temperature (0 – 100)°C
PN-EN 16510-1:2023-06 p. A.4.5.2
363 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
volume flow rate : (0,24 – 12) m3/h
PN-EN 16510-1:2023-06 p. A.4.5.2
364 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding HEAT BALANCE (calculated): PN-EN 16510-1:2023-06 p. A.4.5.2
365 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
heat input from fuel (5 – 60) kW
PN-EN 16510-1:2023-06 p. A.6.2.2
366 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
stack loss (5 – 40) %
PN-EN 16510-1:2023-06 p. A.6.2.1.2
367 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
losses due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.6.2.1.3
368 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
loss due to incomplete combustion
PN-EN 16510-1:2023-06 p. A.6.2.1.4
369 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
thermal efficiency (20 – 95) %
PN-EN 16510-1:2023-06 p. A.6.2.1
370 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
total heat output (3 – 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N”
371 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
heat output of the water circuit (3 – 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N”
372 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
heat output to the room (3 – 50) kW
PN-EN 16510-1:2023-06 p. A.6.2.4
373 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
flue gas mass flow (5 – 100) g/s
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N”
374 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
CO content (O2=13 %) (0,001 – 0,5) %
PN-EN 16510-1:2023-06 p. A.6.2.6
375 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding TECHNICAL AND OPERATIONAL PARAMETERS: PN-EN 16510-1:2023-06 p. A.6.2.6
376 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
temperature of the measuring corner and the floor (0 – 200) °C temperature of the fuel hopper (0 – 200) °C temperature of handles (0 – 300) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.7, A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N”
377 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
tightness of the water space (0,1 – 0,6) MPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N”
378 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
thermal outlet safety device water temperature (0 – 120) °C water pressure (0,1 – 0,3) MPa
PN-EN 16510-1:2023-06 p. A.4.10.7
379 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
tightness (0,016 – 2,6) m3/h
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.11.2 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N”
380 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
tightness related to CO emission (calculated)
PN-EN 16510-1:2023-06 p. 5.9.1
381 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
measurement of electrical energy consumption (1 – 1500) W, method: power transducers
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N”
382 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
temperature safety test
PN-EN 16510-1:2023-06 p. A.4.10.4
383 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
safety test under natural draught
PN-EN 16510-1:2023-06 p. A.4.10.5
384 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
operation of the safety temperature limiter (0 – 110) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.1 „N”
385 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
loss of electrical power supply (0 – 110) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.2 „N”
386 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
loss of heat dissipation (0 – 110) °C, (0 – 5) % CO
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.3 „N”
387 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding
efficiency (calculated) seasonal space heating energy efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6 | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N”
388 Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Dust concentration in flue gases
Range (0,003 – 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Method: gravimetric PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”
389 Solid fuel heat storage local space heaters FUEL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”
390 Solid fuel heat storage local space heaters
fuel mass (0,1 – 20) kg
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 A3; A4.2 „N”
391 Solid fuel heat storage local space heaters FLUE GAS PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 A3; A4.2 „N”
392 Solid fuel heat storage local space heaters
temperature (0 – 600) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.2.3.2; A.4.4.3 „N”
393 Solid fuel heat storage local space heaters
pressure (0,01 – 250) Pa;
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.2.3.4; A.4 „N”
394 Solid fuel heat storage local space heaters Concentrations of carbon dioxide, carbon monoxide, oxygen
CO2; (0,1 – 20) % CO; (0,001 – 0,5) % O2; (0,1 – 21) % O2; (0 – 21) % CO emission (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
NDIR method; Method: PMD - paramagnetic; Electrochemical method PN-EN 15250:2009 p. A.2.3.3; A.4.4.2 „N”
395 Solid fuel heat storage local space heaters Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.
NO (0,5 – 200) ppm NOx (0,5 – 200) ppm OGC; (0,269 –1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated)
Chemiluminescence method; FID method PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E
396 Solid fuel heat storage local space heaters AIR PARAMETERS: PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E
397 Solid fuel heat storage local space heaters
temperature (10 – 35) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”
398 Solid fuel heat storage local space heaters HEAT BALANCE (calculated):
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”
399 Solid fuel heat storage local space heaters
heat energy supplied with the fuel (10 – 600) MJ
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.2 „N”
400 Solid fuel heat storage local space heaters
stack loss (5 – 40) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.1.2„N“
401 Solid fuel heat storage local space heaters
losses due to incomplete combustion
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.1.3„N“
402 Solid fuel heat storage local space heaters
loss due to incomplete combustion
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.1.4„N“
403 Solid fuel heat storage local space heaters
thermal efficiency (20 – 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.1.1„N“
404 Solid fuel heat storage local space heaters
heat output (10 – 600) MJ
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.2 „N“
405 Solid fuel heat storage local space heaters
flue gas mass flow (5 – 100) g/s
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.3 „N“
406 Solid fuel heat storage local space heaters
CO content (O2=13 %) (0,001 – 0,5) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.4 „N“
407 Solid fuel heat storage local space heaters
mean temperature difference between the heater surface and the surroundings (0 – 200) K
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.7 „N“
408 Solid fuel heat storage local space heaters TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.6.2.7 „N“
409 Solid fuel heat storage local space heaters
surface temperature of the storage heater (0 – 200) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.2.5; A.4.6 „N“
410 Solid fuel heat storage local space heaters
temperature of the measuring corner and the floor (0 – 200) °C temperature of the fuel hopper (0 – 200) °C temperature of handles (0 – 300) °C
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 15250:2009 p. A.2.2; A.4.6; A.4.7 „N“
411 Solid fuel heat storage local space heaters Dust concentration in flue gases
Range (0,003 – 1) g/m3
Method: gravimetric PN-EN 16510-1:2023-06 Załącznik F
412 Heating boilers for solid fuels WATER PARAMETERS: PN-EN 16510-1:2023-06 Załącznik F
413 Heating boilers for solid fuels
temperature (0 – 100) °C
PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2
414 Heating boilers for solid fuels
pressure (0 – 0,6) MPa
PN-EN 303-5:2012 p. 5.2
415 Heating boilers for solid fuels
mass flow rate (0 – 12000) kg/h (calculated)
PN-EN 303-5:2012 p. 5.2
416 Heating boilers for solid fuels
volume flow rate : (0,09 – 12) m3/h
PN-EN 303-5:2012 p. 5.2
417 Heating boilers for solid fuels FUEL PARAMETERS: PN-EN 303-5:2012 p. 5.2
418 Heating boilers for solid fuels
mass flow rate (0 – 50) kg/h
PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4
419 Heating boilers for solid fuels FLUE GAS PARAMETERS: PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4
420 Heating boilers for solid fuels
temperature (0 – 600) °C
PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6
421 Heating boilers for solid fuels
pressure (0 – 250) Pa
PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6
422 Heating boilers for solid fuels Concentrations of carbon dioxide, carbon monoxide, oxygen
CO2; (0,1 – 20) % CO; (0,001 – 0,800) % O2; (0,1 – 21) % O2; (0 – 21) % CO emission (calculated)
NDIR method; Method: PMD- paramagnetic; Electrochemical method PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9
423 Heating boilers for solid fuels Concentrations of nitrogen monoxide, nitrogen dioxide, nitrogen oxides (NO, NO2, NOx), OGC.
NO (0,1 – 1993) ppm NO2 (0,1 – 232) ppm NOx (0,1 – 1993) ppm NO (0,5 – 190) ppm NOx (0,5 – 190) ppm OGC; (0,269 – 1286) mg/m3 CO2; NO, NO2, NOx, OGC emission (calculated)
NDIR method; Chemiluminescence method; FID method PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9
424 Heating boilers for solid fuels AMBIENT AIR PARAMETERS AT THE TEST SITE: PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9
425 Heating boilers for solid fuels
temperature (10 – 35) °C
PN-EN 303-5:2012 p. 5.7.1; 5.7.3
426 Heating boilers for solid fuels
pressure (940 – 1060) hPa
PN-EN 297:2002 p. 4.1.6.7
427 Heating boilers for solid fuels HEAT BALANCE (calculated): PN-EN 297:2002 p. 4.1.6.7
428 Heating boilers for solid fuels
heat output (3 – 400) kW
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1
429 Heating boilers for solid fuels
heat input from fuel (3 – 400) kW
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2
430 Heating boilers for solid fuels
thermal efficiency (20 – 95) %
PN-EN 303-5:2012 p.5.10.3
431 Heating boilers for solid fuels
stack loss (5 – 40) %
PN-EN 303-5:2012 p. 5.10.3.2
432 Heating boilers for solid fuels
losses due to incomplete combustion
PN-EN 303-5:2012 p.5.10.3
433 Heating boilers for solid fuels
loss due to incomplete combustion (calculated)
PN-EN 303-5:2012 p.5.10.3
434 Heating boilers for solid fuels
losses to the surroundings
PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3
435 Heating boilers for solid fuels TECHNICAL AND OPERATIONAL PARAMETERS OF THE BOILER: PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3
436 Heating boilers for solid fuels
water flow resistance Water pressure (10 – 2000) Pa
PN-EN 303-5:2012 p.5.11 | PN-EN 304:2017-11 p. 6.6
437 Heating boilers for solid fuels
temperatures of external surfaces (0 – 200) °C
PN-EN 303-5:2012 p. 5.12
438 Heating boilers for solid fuels
temperatures of handles (0 – 300) °C
PN-EN 303-5:2012 p. 5.12
439 Heating boilers for solid fuels
temperature of the floor under the boiler (0 – 200)°C
PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15
440 Heating boilers for solid fuels OPERATION OF AUTOMATIC CONTROLS AND SAFETY DEVICES: PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15
441 Heating boilers for solid fuels
operation of the water temperature controller and the safety temperature limiter (0 – 110) °C
PN-EN 303-5:2012 p. 5.13
442 Heating boilers for solid fuels
operation of the excess heat discharge device water temperature (0 – 120) °C water pressure (0,1 – 0,3) MPa
PN-EN 303-5:2012 p. 5.15
443 Heating boilers for solid fuels Dust concentration in flue gases
Range (0,01 – 1) g/m3
Method: gravimetric PN-EN 303-5:2012 p. 5.2; p.5.7.3; p.5.9, Załącznik A
444 Appliances burning gaseous fuels used for cooking, heating, hot water production, refrigeration, lighting, washing or dishwashing and, where applicable, having a water temperature not exceeding 105°C forced draught burners and heating bodies to be equipped with such burners, (excluding industrial appliances) E, Safety devices, controlling devices or regulating devices and sub-assemblies marketed separately and designed to be incorporated into an appliance burning gaseous fuel or assembled to constitute such an appliance, (excluding industrial appliances) E Characteristics and properties for the assessment of operational safety:
functionality of fittings verification of materials mechanical stability condensation explosion hazard water penetration normal and abnormal supply power fluctuations risk of electric shock pressure resistance reliability of safety, control and regulating devices interaction of control and safety devices protection of components set by the manufacturer control and setting devices release of unburned gas leaks gas accumulation in the appliance and in the room ignition safety combustion quality and stability tightness of the flue gas system spillage of flue gases into the room in the event of draught disturbance heating temperatures of components Hygiene of components in contact with drinking water and food Rational energy consumption
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 12309-1 | PN-EN 12309-2 | PN-EN 13278 | PN-EN 14543 | PN-EN 1596 | PN-EN 203-1 | PN-EN 203-2-1 | PN-EN 203-2-2 | PN-EN 203-2-3 | PN-EN 203-2-4 | PN-EN 203-2-6 | PN-EN 203-2-7 | PN-EN 203-2-8 | PN-EN 203-2-9 | PN-EN 203-2-10 | PN-EN 203-2-11 | PN-EN 26 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 30-1-1 | PN-EN 30-1-2 | PN-EN 30-2-1 | PN-EN 30-2-2 | PN-EN 30-1-3 | PN-EN 30-1-4
445 Appliances burning gaseous fuels used for cooking, heating, hot water production, refrigeration, lighting, washing or dishwashing and, where applicable, having a water temperature not exceeding 105°C forced draught burners and heating bodies to be equipped with such burners, (excluding industrial appliances) E, Safety devices, controlling devices or regulating devices and sub-assemblies marketed separately and designed to be incorporated into an appliance burning gaseous fuel or assembled to constitute such an appliance, (excluding industrial appliances) E Characteristics and properties for the assessment of operational safety:
functionality of fittings verification of materials mechanical stability condensation explosion hazard water penetration normal and abnormal supply power fluctuations risk of electric shock pressure resistance reliability of safety, control and regulating devices interaction of control and protective devices protection of components set by the manufacturer control and setting devices release of unburned gas leaks gas accumulation in the appliance and in the room ignition safety combustion quality and stability tightness of the flue gas system spillage of flue gases into the room in the event of draught disturbance heating temperatures of components Hygiene of components in contact with drinking water and food Rational energy consumption
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 303-3 | PN-EN 416 z wyłączeniem punktów 7.1 ; 7.2 ; 7.3 ; 7.4 ; 7.5 | PN-EN 419 z wyłączeniem punktu 7 | PN-EN 449 | PN-EN 461 | PN-EN 15502-1 | PN-EN 15502-2-1 z wyłączeniem punktów 8.102 ; 8.103 | PN-EN 15502-2-2 | PN-EN 484 | PN-EN 497 | PN-EN 498 | PN-EN 509 | PN-EN 521 | PN-EN 613 | PN-EN 624 | PN-EN 732 | PN-EN 751-1 | PN-EN 751-2 | PN-EN 751-3 | PN-EN 89 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 437 | PN-EN 14829 | PN-EN 17082 | PN-EN 17175
446 Gas lighters and igniters E Ignition mechanism
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
447 Gas lighters and igniters E Flame height
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
448 Gas lighters and igniters E Flame height adjustment
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
449 Gas lighters and igniters E Resistance to spitting
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
450 Gas lighters and igniters E Flame extinguishment
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
451 Gas lighters and igniters E Vol. Capacity reserve
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
452 Gas lighters and igniters E External finishing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
453 Gas lighters and igniters E Suitability of the container for the type of gas
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
454 Gas lighters and igniters E Resistance to fuel loss
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
455 Gas lighters and igniters E Resistance to elevated temperature
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
456 Gas lighters and igniters E Resistance to internal pressure
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
457 Gas lighters and igniters E Resistance to a burning flame
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
458 Gas lighters and igniters E Resistance to intermittent burning
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
459 Gas lighters and igniters E Resistance to continuous burning
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 9994
460 Gas lighters and igniters E Child resistance of lighter ignition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 13869
461 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Mechanical strength
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1859 | PN-EN 14989-2
462 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Leak tightness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1859 | PN-EN 14989-2
463 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Thermal performance of the chimney
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1859 | PN-EN 14989-2
464 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Thermal strength
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1859 | PN-EN 14989-2
465 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Resistance to water vapour diffusion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1859 | PN-EN 14989-2
466 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Resistance to gas condensate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1859 | PN-EN 14989-2
467 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Resistance to rainwater penetration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1859 | PN-EN 14989-2
468 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Flow resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1859 | PN-EN 14989-2
469 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Aerodynamic resistance of chimney terminals
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1859 | PN-EN 14989-2
470 Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Fire test of small chimneys
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-B-02870
471 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Thermal performance of the chimney
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
472 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Thermal strength
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
473 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Flow resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
474 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Leak tightness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
475 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Abrasion resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
476 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Compressive strength
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
477 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Resistance to condensate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
478 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Flexural strength under wind load
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
479 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Flexural strength
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
480 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Resistance to alternate freezing and thawing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
481 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Acid resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
482 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Thermal resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
483 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Resistance to water and water vapour diffusion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1
484 Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Fire test of small chimneys
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
PN-B-02870
Laboratory of Geophysical Parameters of Rocks and Reservoir Fluids (SW-1)
485 Rocks Density – helium method
Range (1,600 – 7,400) g/cm3 Volumetric density – powder method (Dry Flo) Range (1,500 – 5,000) g/cm3 Porosity calculation method
PB-02/SW-1 wydanie 4 z dnia 30.01.2015 r.
Petroleum and Gas Geochemistry Laboratory (SG-1)
486 Coal, heating oil, diesel oil Gross calorific value:
Range (15000 – 48000) J/g
Calorimetric method PB-02/SG-1 wydanie 4 z dnia 10.10.2013 r.
487 Coal, carbon black, heating oil, diesel oil Determination of the content of the element carbon
Range (30,00 – 99,00) % m/m
Gas chromatography with conductometric detection (GC – TCD) PB-01/SG-1 wydanie 5 z dnia 18.01.2021 r.
488 Soils, rocks, mineral raw materials Determination of organic carbon content
Range (0,05 – 80,00) % m/m
High-temperature combustion method with infrared detection (IR) PB-03/SG-1 wydanie 1 z dnia 10.02.2015 r.
Gaseous Fuels Odorisation Department (WN)
489 Gaseous fuels: natural gas, Gases: gas mixtures (including synthetic THT mixtures) Tetrahydrothiophene (THT) content
Range (10,0 – 35,0) mg/m3 Range (2,5 – 10,0) ppm
Gas chromatography with pulsed flame photometric detection (GC-PFPD) and with electrochemical detection (GC-ED) PB WN-1 wydanie 5 z 20.06.2022 r.
490 Gases: gas mixtures (including synthetic gas mixtures) Tetrahydrothiophene (THT) content
Range (15,0 – 75,0) mg/m3 Range (4,0 – 20,0) ppm
Gas chromatography with electrochemical detection (GC-ED) PB WN-2 Wydanie 6 z 20.06.2022 r.
Test methods
491 Type of activity: ASSESSMENT OF PERFORMANCE ON THE BASIS OF TESTING, CALCULATION, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3) Reference document:
Regulated area: The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope.
Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.)
492 Commission decision number Product(s)
Regulated area: The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope.
Zharmonizowane specyfikacje techniczne
493 99/471/EC Space heaters fired with solid and liquid fuels
Regulated area: The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope.
EN 15250:2007 | EN 16510-2-1 :2022 | EN 16510-2-2 :2022 | EN 16510-2-3 :2022 | EN 16510-2-6 :2022

Reference standards (428)

01/GE-1/22
02/GE-1/22
04/GE-1/22
05/GE-1/22
DIN 30670
DIN 30670-1
DIN 30670-2
EN 15250:2007
EN 16510-2-1 :2022
EN 16510-2-2 :2022
EN 16510-2-3 :2022
EN 16510-2-6 :2022
ISO 13953
ISO 13954
ISO 13955
ISO 13956
ISO 18488
ISO 18489
OIML R 137-1&2:2012 p. 12.6.11
OIML R 137-1&2:2012 p. 12.6.4 12.6.10
OIML R 137-1&2:2012 p. 12.6.5
OIML R 137-1&2:2012 p. 12.6.7;
OIML R 137-1&2:2012 p. 12.6.8
OIML R 137-1&2:2012 p. 6.1.2
OIML R 137-1&2:2012 p. A.4.1.1; A.4.1.2; A.4.2.1; A.4.2.2
OIML R 137-1&2:2012 p. A.6.2; A.6.3
OIML R 137-1&2:2012 p.12.6.1; 12.6.2; 12.6.3; 12.6.9; 12.6.13; A.5.1; A.5.2
OIML R 137-1&2:2012 p.A.8
OIML R 137-1&2:2012, 6.3.4; 6.4.2; 6.4.3; 6.4.5
PB GM-01
PB GM-08C wydanie 1 z dnia 20.03.2017
PB WN-1 wydanie 5 z 20.06.2022 r.
PB WN-2 Wydanie 6 z 20.06.2022 r.
PB-01/SG-1 wydanie 5 z dnia 18.01.2021 r.
PB-02/SG-1 wydanie 4 z dnia 10.10.2013 r.
PB-02/SW-1 wydanie 4 z dnia 30.01.2015 r.
PB-03/SG-1 wydanie 1 z dnia 10.02.2015 r.
PN-79/M-54840 p.4.3.2
PN-B-02870
PN-EN 10226-1 „N”
PN-EN 10290
PN-EN 1074-1 p.5.1
PN-EN 1074-1 p.5.2
PN-EN 1074-1 p.5.5
PN-EN 1112
PN-EN 1113
PN-EN 12068
PN-EN 12106
PN-EN 1213
PN-EN 12261 p. 5.2.1, 5.2.2, 5.2.3, 5.2.5, 5.2.6, 5.2.8, Załącznik B, 5.2.9
PN-EN 12261 p. 5.2.7
PN-EN 12261 p.4
PN-EN 12261 p.6.2.3, 6.2.5, 6.2.6, 6.3.3, 6.3.3.1, 6.3.3.2, 6.3.3.3, 6.6.1, 6.6.1.1, 6.6.1.2, 6.6.2, 6.7
PN-EN 12261 p.7.2.3, 7.3.1, 7.3.2.2, 7.5
PN-EN 12266-1, A.3
PN-EN 12266-1, A.4
PN-EN 12266-1, załącznik A2
PN-EN 12266-1, załącznik A3
PN-EN 12266-1A2
PN-EN 12293:2002
PN-EN 12309-1
PN-EN 12309-2
PN-EN 12405-1
PN-EN 12405-1 + p.C.7.2
PN-EN 12405-1 Załącznik C
PN-EN 12405-1 p. A18
PN-EN 12405-1 p. A19
PN-EN 12405-1 p. A20
PN-EN 12405-1 p. A9
PN-EN 12405-1 p.9.1, 9,2
PN-EN 12405-1 p.A10
PN-EN 12405-1 p.A11
PN-EN 12405-1 p.A12
PN-EN 12405-1 p.A13
PN-EN 12405-1 p.A14
PN-EN 12405-1 p.A15
PN-EN 12405-1 p.A16
PN-EN 12405-1 p.A17
PN-EN 12405-1 p.A2
PN-EN 12405-1 p.A3
PN-EN 12405-1 p.A4
PN-EN 12405-1 p.A5
PN-EN 12405-1 p.A6
PN-EN 12405-1 p.A7
PN-EN 12405-1 p.A8
PN-EN 12405-1 p.B4
PN-EN 12405-1 p.D4
PN-EN 12446
PN-EN 12480
PN-EN 12809:2002 p. A.1.1.
PN-EN 12809:2002 p. A.2.3.2.
PN-EN 12809:2002 p. A.2.3.3
PN-EN 12809:2002 p. A.2.3.4; A4
PN-EN 12809:2002 p. A.2.5
PN-EN 12809:2002 p. A.2; A.3
PN-EN 12809:2002 p. A.4.10
PN-EN 12809:2002 p. A.4.2
PN-EN 12809:2002 p. A.6.2.1
PN-EN 12809:2002 p. A.6.2.1.1
PN-EN 12809:2002 p. A.6.2.1.2
PN-EN 12809:2002 p. A.6.2.1.3
PN-EN 12809:2002 p. A.6.2.2
PN-EN 12809:2002 p. A.6.2.3
PN-EN 12809:2002 p. A.6.2.4
PN-EN 12809:2002 p. A.6.2.5
PN-EN 12809:2002 p. A.6.2.6
PN-EN 13069
PN-EN 13278
PN-EN 13278 :2003
PN-EN 13502
PN-EN 1359
PN-EN 13774 p.5.5
PN-EN 13828
PN-EN 13828 p.7.1
PN-EN 13828 p.7.4.1
PN-EN 13869
PN-EN 14236:2019-01 12.1, 12.2, 12.3
PN-EN 14236:2019-01 5.3.2, 5.4, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11, 5.12, 5.13, 5.14
PN-EN 14236:2019-01 6.2.3 6.2.4 6.2.5 6.2.6.1 6.2.6.2 6.2.6.3 6.2.6.4 6.2.7 6.2.8 6.2.9 6.3.2.1, 6.4.1 6.3.2.2, 6.3.4.1 6.3.2.3, 6.3.4.2 6.3.2.4, 6.3.3.1, 6.3.4.3, 6.3.5.1 6.3.2.5, 6.3.3.2 6.3.2.6, 6.3.3.3, 6.3.4.4, 6.3.5.2, 6.4.2 6.8 6.10 6.11 6.12 6.13
PN-EN 14236:2019-01 7.1, 7.2, 7.2.3, 7.3 (Załącznik C)
PN-EN 14236:2019-01 8.2, 8.3, 8.4
PN-EN 14543
PN-EN 1457-1
PN-EN 1457-2
PN-EN 14829
PN-EN 14989-1
PN-EN 14989-2
PN-EN 15250:2009 A3; A4.2 „N”
PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”
PN-EN 15250:2009 p. A.2.2; A.4.6; A.4.7 „N“
PN-EN 15250:2009 p. A.2.3.2; A.4.4.3 „N”
PN-EN 15250:2009 p. A.2.3.3; A.4.4.2 „N”
PN-EN 15250:2009 p. A.2.3.4; A.4 „N”
PN-EN 15250:2009 p. A.2.5; A.4.6 „N“
PN-EN 15250:2009 p. A.6.2.1.1„N“
PN-EN 15250:2009 p. A.6.2.1.2„N“
PN-EN 15250:2009 p. A.6.2.1.3„N“
PN-EN 15250:2009 p. A.6.2.1.4„N“
PN-EN 15250:2009 p. A.6.2.2 „N“
PN-EN 15250:2009 p. A.6.2.2 „N”
PN-EN 15250:2009 p. A.6.2.3 „N“
PN-EN 15250:2009 p. A.6.2.4 „N“
PN-EN 15250:2009 p. A.6.2.7 „N“
PN-EN 15502-1
PN-EN 15502-1:2012
PN-EN 15502-2-1 z wyłączeniem punktów 8.102 ; 8.103
PN-EN 15502-2-2
PN-EN 1555-2 pkt.9.3
PN-EN 1596
PN-EN 16314:2013-11E 4.12.2 4.12.3
PN-EN 16314:2013-11E 4.9.2.2 b) 4.9.5
PN-EN 16314:2013-11E 6.5 6.7 6.8
PN-EN 16314:2013-11E 7.13.3; 7.13.4.1.2; 7.13.4.2; 7.13.4.4; 7.13.4.5; 7.13.4.6; 7.13.4.7; D.3 D.4 D.5
PN-EN 16314:2013-11E 7.4; 7.13.4.8 7.13.4.9 7.18.3; C.5 C.9
PN-EN 16314:2013-11E p. 4.14
PN-EN 16314:2013-11E p. 4.16
PN-EN 16314:2013-11E p.4.15
PN-EN 16510-1:2018-08 Załącznik F
PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E
PN-EN 16510-1:2018-08 p. A.2.3.3
PN-EN 16510-1:2018-08 p. A.4.10.5
PN-EN 16510-1:2018-08 p. A.4.11.2
PN-EN 16510-1:2018-08 p. A.4.2
PN-EN 16510-1:2018-08 p. A.6.2.5
PN-EN 16510-1:2018-08 p.A.1.1
PN-EN 16510-1:2018-08 p.A.2.5
PN-EN 16510-1:2018-08 p.A.2.; A.3
PN-EN 16510-1:2018-08 p.A.6.2.1.1
PN-EN 16510-1:2018-08 p.A.6.2.1.2
PN-EN 16510-1:2018-08 p.A.6.2.1.3
PN-EN 16510-1:2018-08 p.A.6.2.1.4
PN-EN 16510-1:2018-08 p.A.6.2.2
PN-EN 16510-1:2018-08 p.A.6.2.3
PN-EN 16510-1:2018-08 p.A.6.2.4
PN-EN 16510-1:2018-08 p.A.6.2.5
PN-EN 16510-1:2018-08 p.A.6.2.6
PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E
PN-EN 16510-1:2023-06
PN-EN 16510-1:2023-06 Załącznik F
PN-EN 16510-1:2023-06 p . A.6.2.1.5, A.6.2.1.6,
PN-EN 16510-1:2023-06 p 5.9.1
PN-EN 16510-1:2023-06 p 6.11
PN-EN 16510-1:2023-06 p A.4.10.4
PN-EN 16510-1:2023-06 p A.4.10.5
PN-EN 16510-1:2023-06 p. 5.9.1
PN-EN 16510-1:2023-06 p. 6.11
PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3
PN-EN 16510-1:2023-06 p. A.2.3.2, A.4.4.3
PN-EN 16510-1:2023-06 p. A.2.3.2; A.4.4.3
PN-EN 16510-1:2023-06 p. A.2.3.4; A.4
PN-EN 16510-1:2023-06 p. A.2.3; A.4.4.2
PN-EN 16510-1:2023-06 p. A.2.5; A.4.5
PN-EN 16510-1:2023-06 p. A.4.10.4
PN-EN 16510-1:2023-06 p. A.4.10.5
PN-EN 16510-1:2023-06 p. A.4.10.6
PN-EN 16510-1:2023-06 p. A.4.10.7
PN-EN 16510-1:2023-06 p. A.4.11.2
PN-EN 16510-1:2023-06 p. A.4.2
PN-EN 16510-1:2023-06 p. A.4.4, A.6.2.1.2
PN-EN 16510-1:2023-06 p. A.4.4.2
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E
PN-EN 16510-1:2023-06 p. A.4.4.3
PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.3
PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.4
PN-EN 16510-1:2023-06 p. A.4.5.2
PN-EN 16510-1:2023-06 p. A.4.5; A.4.8; A.4.9, A.6.2.2
PN-EN 16510-1:2023-06 p. A.4.7
PN-EN 16510-1:2023-06 p. A.4.7, A.4.8, A.4.9, A.4.10
PN-EN 16510-1:2023-06 p. A.4.7; A.4.8, A.4.9, A.4.10
PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10
PN-EN 16510-1:2023-06 p. A.6.2.1
PN-EN 16510-1:2023-06 p. A.6.2.1.2
PN-EN 16510-1:2023-06 p. A.6.2.1.3
PN-EN 16510-1:2023-06 p. A.6.2.1.4
PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.
PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6
PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6,
PN-EN 16510-1:2023-06 p. A.6.2.2
PN-EN 16510-1:2023-06 p. A.6.2.3
PN-EN 16510-1:2023-06 p. A.6.2.4
PN-EN 16510-1:2023-06 p. A.6.2.5
PN-EN 16510-1:2023-06 p. A.6.2.6
PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E
PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E
PN-EN 16510-2-1:2023-06 p. 4.3 „N“
PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“
PN-EN 16510-2-1:2023-06 p. 4.6 „N”
PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“
PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N”
PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N”
PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N”
PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N”
PN-EN 16510-2-1:2023-06 p. 5.3 „N”
PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“
PN-EN 16510-2-1:2023-06 p.4.7.2, 4.7.3, 4.7.8 „N“
PN-EN 16510-2-2:2023-06 p. 4.2 „N“
PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“
PN-EN 16510-2-2:2023-06 p. 4.5 „N”
PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N”
PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5 „N”
PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N”
PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N”
PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N”
PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N”
PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N”
PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”
PN-EN 16510-2-2:2023-06 p. 5.3.3 „N”
PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N”
PN-EN 16510-2-3:2023-06 p. 4.2 „N”
PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”
PN-EN 16510-2-3:2023-06 p. 4.5 „N”
PN-EN 16510-2-3:2023-06 p. 4.6.2, 4.6.3 „N”
PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”
PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”
PN-EN 16510-2-3:2023-06 p. 5.3.3 „N”
PN-EN 16510-2-3:2023-06 p. 5.5, 5.6 „N”
PN-EN 16510-2-3:2023-06 p. A.4.301.4 „N”
PN-EN 16510-2-3:2023-06 p. A.4.301.5 „N”
PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N”
PN-EN 16510-2-6:2023-06 p. 4.3 „N”
PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”
PN-EN 16510-2-6:2023-06 p. 4.6 „N”
PN-EN 16510-2-6:2023-06 p. 4.7.2, 4.7.3 „N”
PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N”
PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N”
PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N”
PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N”
PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N”
PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N”
PN-EN 16510-2-6:2023-06 p. 5.3.3 „N”
PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N”
PN-EN 16510-2-6:2023-06 p. A.4.10.601.1 „N”
PN-EN 16510-2-6:2023-06 p. A.4.10.601.2 „N”
PN-EN 16510-2-6:2023-06 p. A.4.10.601.3 „N”
PN-EN 16510:2018-08 p. A.2.3.2
PN-EN 16510:2018-08 p. A.2.3.4; A.4
PN-EN 16510:2023-06 p. A.4.10.7
PN-EN 17082
PN-EN 1716
PN-EN 17175
PN-EN 1775
PN-EN 1775 Procedura B „N”
PN-EN 1856-1
PN-EN 1856-2
PN-EN 1857
PN-EN 1858
PN-EN 1859
PN-EN 203-1
PN-EN 203-1+A1 :2010
PN-EN 203-2-1
PN-EN 203-2-1 :2010
PN-EN 203-2-10
PN-EN 203-2-11
PN-EN 203-2-2
PN-EN 203-2-3
PN-EN 203-2-3 :2006
PN-EN 203-2-4
PN-EN 203-2-6
PN-EN 203-2-7
PN-EN 203-2-7:2007
PN-EN 203-2-8
PN-EN 203-2-9
PN-EN 26 z wyłączeniem punktów : 8.7 i 8.8
PN-EN 26:2007
PN-EN 297:2002 p. 4.1.6.7
PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006
PN-EN 30-1-1
PN-EN 30-1-1+A2: 2010
PN-EN 30-1-2
PN-EN 30-1-2:2002
PN-EN 30-1-3
PN-EN 30-1-4
PN-EN 30-1-4 :2011
PN-EN 30-2-1
PN-EN 30-2-1:2006
PN-EN 30-2-2
PN-EN 303-3
PN-EN 303-5:2012 p. 5.10.3.2
PN-EN 303-5:2012 p. 5.12
PN-EN 303-5:2012 p. 5.13
PN-EN 303-5:2012 p. 5.15
PN-EN 303-5:2012 p. 5.2
PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9
PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4
PN-EN 303-5:2012 p. 5.2; p.5.7.3; p.5.9, Załącznik A
PN-EN 303-5:2012 p. 5.7.1; 5.7.3
PN-EN 303-5:2012 p. 5.7.3
PN-EN 303-5:2012 p.5.10.3
PN-EN 303-5:2012 p.5.11
PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1
PN-EN 304:2017-11 p. 6.15
PN-EN 304:2017-11 p. 6.6
PN-EN 304:2017-11 p. A.8.3
PN-EN 304:2017-11 rys.4,5,6
PN-EN 331:2005/A1:2011E p.7.2
PN-EN 331:2005/A1:2011E p.7.3
PN-EN 331:2005/A1:2011E p.7.4
PN-EN 331:2005/A1:2011E p.7.5
PN-EN 331:2005/A1:2011E p.7.6
PN-EN 331:2005/A1:2011E p.7.6.5
PN-EN 331:2005/A1:2011E p.7.7
PN-EN 331:2005/A1:2011E p.7.8
PN-EN 331:2005P p.7.2
PN-EN 331:2005P p.7.3
PN-EN 331:2005P p.7.4
PN-EN 331:2005P p.7.5
PN-EN 331:2005P p.7.6
PN-EN 331:2005P p.7.6.5
PN-EN 331:2005P p.7.7
PN-EN 331:2005P p.7.8
PN-EN 416 z wyłączeniem punktów 7.1 ; 7.2 ; 7.3 ; 7.4 ; 7.5
PN-EN 419 z wyłączeniem punktu 7
PN-EN 437
PN-EN 449
PN-EN 461
PN-EN 483:2007
PN-EN 484
PN-EN 497
PN-EN 498
PN-EN 498:2002
PN-EN 509
PN-EN 521
PN-EN 60068-2-1
PN-EN 60068-2-2
PN-EN 60068-2-30
PN-EN 60068-2-31
PN-EN 60068-2-78
PN-EN 60068-3-1
PN-EN 60751
PN-EN 61000-4-11
PN-EN 61000-4:11
PN-EN 613
PN-EN 624
PN-EN 625:2002
PN-EN 677:2007
PN-EN 732
PN-EN 751-1
PN-EN 751-2
PN-EN 751-3
PN-EN 817
PN-EN 89 z wyłączeniem punktów : 8.7 i 8.8
PN-EN 89:2002+A3:2006+A4:2006
PN-EN 9994
PN-EN ISO 10715
PN-EN ISO 1133-1
PN-EN ISO 1133:2006
PN-EN ISO 1167-1
PN-EN ISO 1183-1
PN-EN ISO 13056
PN-EN ISO 13479
PN-EN ISO 1518-1
PN-EN ISO 19739
PN-EN ISO 19892
PN-EN ISO 21809-1
PN-EN ISO 21809-2
PN-EN ISO 228-1
PN-EN ISO 228-1 „N”
PN-EN ISO 2505
PN-EN ISO 2808
PN-EN ISO 2812-1
PN-EN ISO 3126
PN-EN ISO 3503
PN-EN ISO 527-1
PN-EN ISO 527-2
PN-EN ISO 527-3
PN-EN ISO 6259-1
PN-EN ISO 6270-1
PN-EN ISO 6974-5 03/GE-1/22
PN-EN ISO 6976
PN-EN ISO 6976:2008
PN-EN ISO 9227
PN-ISO 7253:2000
PN-ISO 7253:2000/Ap1:2001
PN-M-75002
PN-M-75002 p 6.2.5
Procedura P-21
Procedura P-23
Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. 2008 nr 18 poz. 115)
Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.)
Zharmonizowane specyfikacje techniczne