{"lab":{"_id":"69ad52a3de79e566650fb0e1","accr_number":"AB 041","country":"PL","accr_body":"PCA","address":"ul. Lubicz 25a, 31-503 Kraków, ZESPÓŁ LABORATORIÓW BADAWCZYCH, SIECI, INSTALACJI I URZĄDZEŃ GAZOWYCH, ul. Bagrowa 1, 30-733 Kraków","categories":["petro","water","materials","metrology","environment","construction"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":493,"name":"INSTYTUT NAFTY I GAZU – PAŃSTWOWY INSTYTUT BADAWCZY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_041.pdf"],"scope_summary":"","search_text":"instytut nafty i gazu – państwowy instytut badawczy ul. lubicz 25a, 31-503 kraków, zespół laboratoriów badawczych, sieci, instalacji i urządzeń gazowych, ul. bagrowa 1, 30-733 kraków petro other water environment metrology materials food electronics pharma automotive construction","status":"active","updated_at":"2026-03-08T14:50:05.224Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:44:57.775Z","parse_date":"2026-08-13T07:44:57.775Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://inig.pl/kontakt","fields_of_testing":[{"codes":"C/5; C/9; C/10; C/31; C/36","pl":"Badania chemiczne materiałów budowlanych, powietrza, paliw, gleby, skał, gazów","en":"Chemical tests of building materials, air, fuels, soil, rocks, gases"},{"codes":"E/6; E/8; E/17; E/21","pl":"Badania elektryczne wyrobów i wyposażenia elektrycznego, wyrobów konstrukcyjnych, wyrobów innych, wyrobów z tworzyw sztucznych i gumy","en":"Electric tests of electrical products and equipment, construction products, other products, plastic and rubber products"},{"codes":"F/6; F/13","pl":"Badania kompatybilności elektromagnetycznej (EMC) wyrobów i wyposażenia elektrycznego, maszyn i urządzeń","en":"Electromagnetic compatibility (EMC) tests of electrical products and equipment machinery and devices"},{"codes":"H/5","pl":"Badania ogniowe wyrobów i materiałów budowlanych","en":"Fire tests of building products, building materials"},{"codes":"J/5; J/6; J/8; J/13; J/21","pl":"Badania mechaniczne wyrobów i materiałów budowlanych, wyrobów i wyposażenia elektrycznego, wyrobów konstrukcyjnych, maszyny i urządzeń, wyrobów z tworzyw sztucznych i gumy","en":"Mechanical tests of building products, building materials, electrical products and equipment, construction products, machinery and devices, plastic and rubber products"},{"codes":"L/5; L/21","pl":"Badania nieniszczące wyrobów i materiałów budowlanych, wyrobów z tworzyw sztucznych i gumy","en":"Non-destructive tests of building products, building materials, plastic and rubber products"},{"codes":"M/5; M/6; M/13; M/17; M/21","pl":"Badania inne wyrobów i materiałów budowlanych, wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, wyrobów innych, wyrobów z tworzyw sztucznych i gumy","en":"Other tests of building products, building materials, electrical products and equipment, machinery and devices, other products, plastic and rubber products"}],"issue":{"no":"32","date":"15.06.2026"},"map_coord":[50.065183,19.953953],"map_geo":"nominatim-street","lab_locations":[{"name":"ZESPÓŁ LABORATORIÓW BADAWCZYCH","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"Laboratorium Metrologii Przepływów (GM-1)","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"Laboratorium Tworzyw Sztucznych (GP-3)","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"Laboratorium Geofizycznych Parametrów Skał i Płynów Złożowych (SW-1)","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"Laboratorium Geochemii Nafty i Gazu (SG-1)","address":"ul. Lubicz 25 A, 31-503 Kraków","city":"Kraków","postal":"31-503"},{"name":"Zakład Nawaniania Paliw Gazowych (WN)","address":"ul. Kasprzaka 25, 01-224 Warszawa","city":"Warszawa","postal":"01-224"}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/3cb16266167d210bf028912a82c4dcbe/AB%20041.pdf","has_en":true,"category_counts":{"petro":282,"other":112,"water":39,"materials":37,"metrology":29,"environment":22,"construction":17,"electronics":4,"food":3},"category_scores":{"petro":145.92,"other":23.02,"water":2.79,"materials":2.51,"metrology":1.54,"environment":0.89,"construction":0.53,"electronics":0.03,"food":0.02},"has_zh":true,"lab_locations_zh":[{"name":"ZESPÓŁ LABORATORIÓW BADAWCZYCH","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"气候与资源保护实验室（GE-1）","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"流量计量实验室（GM-1）","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"燃气管道阀门与运行技术检测实验室（GP-1）","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"塑料实验室（GP-3）","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"燃气与供暖器具检测实验室（GU-1）","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"Laboratorium Geofizycznych Parametrów Skał i Płynów Złożowych (SW-1)","address":"ul. Bagrowa 1, 30-733 Kraków","city":"Kraków","postal":"30-733"},{"name":"石油与天然气地球化学实验室（SG-1）","address":"ul. Lubicz 25 A, 31-503 Kraków","city":"Kraków","postal":"31-503"},{"name":"Zakład Nawaniania Paliw Gazowych (WN)","address":"ul. Kasprzaka 25, 01-224 Warszawa","city":"Warszawa","postal":"01-224"}]},"methods":[{"_id":"6a7d75f9441eff5f156487db","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz rafineryjny, gaz ziemny, biogaz, mieszaniny gazowe","methodology":"Ciepło spalania, Wartość opałowa, Gęstość, gęstość względna, Liczba Wobbego","parameters":[],"technique":"Metoda obliczeniowa na podstawie składu gazu","techniques":["Metoda obliczeniowa na podstawie składu gazu"],"computed":[],"activity":"Ciepło spalania, Wartość opałowa, Gęstość, gęstość względna, Liczba Wobbego\nMetoda obliczeniowa na podstawie składu gazu","reference":"PN-EN ISO 6976:2008","norm_bases":["PN-EN ISO 6976:2008"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaz rafineryjny, gaz ziemny, biogaz, mieszaniny gazowe Ciepło spalania, Wartość opałowa, Gęstość, gęstość względna, Liczba Wobbego\nMetoda obliczeniowa na podstawie składu gazu PN-EN ISO 6976:2008 Gaz rafineryjny, gaz ziemny, biogaz, mieszaniny gazowe Cieplo spalania, Wartosc opalowa, Gestosc, gestosc wzgledna, Liczba Wobbego\nMetoda obliczeniowa na podstawie skladu gazu PN-EN ISO 6976:2008","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"Gross calorific value, Net calorific value, Density, relative density, Wobbe index","search_en":"Refinery gas, natural gas, biogas, gas mixtures Gross calorific value, Net calorific value, Density, relative density, Wobbe index Calculation method based on gas composition Climate and Resources Protection Laboratory (GE-1) PN-EN ISO 6976:2008","technique_en":"Calculation method based on gas composition","test_object_en":"Refinery gas, natural gas, biogas, gas mixtures","lab_section_zh":"气候与资源保护实验室（GE-1）","search_zh":"燃烧热、低位发热量、密度、相对密度、沃泊指数 依据气体组成的计算法 气候与资源保护实验室（GE-1） PN-EN ISO 6976:2008","methodology_zh":"燃烧热、低位发热量、密度、相对密度、沃泊指数","technique_zh":"依据气体组成的计算法"},{"_id":"6a7d75f9441eff5f156487dc","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz ziemny, biogaz, mieszaniny gazowe E","methodology":"Pobieranie próbek gazu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek gazu","reference":"PN-EN ISO 10715","norm_bases":["PN-EN ISO 10715"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gaz ziemny, biogaz, mieszaniny gazowe E Pobieranie próbek gazu PN-EN ISO 10715 Gaz ziemny, biogaz, mieszaniny gazowe E Pobieranie probek gazu PN-EN ISO 10715","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"Gas sampling","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Natural gas, biogas, gas mixtures E Gas sampling Climate and Resources Protection Laboratory (GE-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 10715","test_object_en":"Natural gas, biogas, gas mixtures E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"天然气、沼气、混合气体 E 气候与资源保护实验室（GE-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 10715","lab_section_zh":"气候与资源保护实验室（GE-1）","test_object_zh":"天然气、沼气、混合气体 E"},{"_id":"6a7d75f9441eff5f156487dd","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz ziemny, biogaz, mieszaniny gazowe E","methodology":"Stężenie węglowodorów C1 – C5, C6+","parameters":[{"name":"metan (0,0001 – 100) % (mol/mol)"},{"name":"etan (0,0001 – 20) % (mol/mol)"},{"name":"propan (0,0001 – 5) % (mol/mol)"},{"name":"butany (0,0001 – 1) % (mol/mol)"},{"name":"pentany (0,0001 – 0,5) % (mol/mol)"},{"name":"C6+ (0,0001 – 1) % (mol/mol) Stężenie N2 i CO2"},{"name":"N2 (0,005 – 80) % (mol/mol)"},{"name":"CO2 (0,005 – 80) % (mol/mol)"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Stężenie węglowodorów C1 – C5, C6+\nZakres:\nmetan (0,0001 – 100) % (mol/mol)\netan (0,0001 – 20) % (mol/mol)\npropan (0,0001 – 5) % (mol/mol)\nbutany (0,0001 – 1) % (mol/mol)\npentany (0,0001 – 0,5) % (mol/mol)\nC6+ (0,0001 – 1) % (mol/mol) Stężenie N2 i CO2\nN2 (0,005 – 80) % (mol/mol)\nCO2 (0,005 – 80) % (mol/mol)\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"PN-EN ISO 6974-5 03/GE-1/22","norm_bases":["PN-EN ISO 6974-5 03/GE-1/22"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gaz ziemny, biogaz, mieszaniny gazowe E Stężenie węglowodorów C1 – C5, C6+\nZakres:\nmetan (0,0001 – 100) % (mol/mol)\netan (0,0001 – 20) % (mol/mol)\npropan (0,0001 – 5) % (mol/mol)\nbutany (0,0001 – 1) % (mol/mol)\npentany (0,0001 – 0,5) % (mol/mol)\nC6+ (0,0001 – 1) % (mol/mol) Stężenie N2 i CO2\nN2 (0,005 – 80) % (mol/mol)\nCO2 (0,005 – 80) % (mol/mol)\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) PN-EN ISO 6974-5 03/GE-1/22 Gaz ziemny, biogaz, mieszaniny gazowe E Stezenie weglowodorow C1 – C5, C6+\nZakres:\nmetan (0,0001 – 100) % (mol/mol)\netan (0,0001 – 20) % (mol/mol)\npropan (0,0001 – 5) % (mol/mol)\nbutany (0,0001 – 1) % (mol/mol)\npentany (0,0001 – 0,5) % (mol/mol)\nC6+ (0,0001 – 1) % (mol/mol) Stezenie N2 i CO2\nN2 (0,005 – 80) % (mol/mol)\nCO2 (0,005 – 80) % (mol/mol)\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) PN-EN ISO 6974-5 03/GE-1/22","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"Concentration of C1 – C5, C6+ hydrocarbons","parameters_en":[{"name":"methane (0,0001 – 100) % (mol/mol)"},{"name":"ethane (0,0001 – 20) % (mol/mol)"},{"name":"propane (0,0001 – 5) % (mol/mol)"},{"name":"butanes (0,0001 – 1) % (mol/mol)"},{"name":"pentanes (0,0001 – 0,5) % (mol/mol)"},{"name":"C6+ (0,0001 – 1) % (mol/mol) N2 and CO2 concentration"},{"name":"N2 (0,005 – 80) % (mol/mol)"},{"name":"CO2 (0,005 – 80) % (mol/mol)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Natural gas, biogas, gas mixtures E Concentration of C1 – C5, C6+ hydrocarbons Gas chromatography with thermal conductivity detection (GC-TCD) Climate and Resources Protection Laboratory (GE-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. methane (0,0001 – 100) % (mol/mol) ethane (0,0001 – 20) % (mol/mol) propane (0,0001 – 5) % (mol/mol) butanes (0,0001 – 1) % (mol/mol) pentanes (0,0001 – 0,5) % (mol/mol) C6+ (0,0001 – 1) % (mol/mol) N2 and CO2 concentration N2 (0,005 – 80) % (mol/mol) CO2 (0,005 – 80) % (mol/mol) PN-EN ISO 6974-5 03/GE-1/22","technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","test_object_en":"Natural gas, biogas, gas mixtures E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"天然气、沼气、混合气体 E 气相色谱-热导检测法（GC-TCD） 气候与资源保护实验室（GE-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 6974-5 03/GE-1/22","technique_zh":"气相色谱-热导检测法（GC-TCD）","lab_section_zh":"气候与资源保护实验室（GE-1）","test_object_zh":"天然气、沼气、混合气体 E"},{"_id":"6a7d75f9441eff5f156487de","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz ziemny, biogaz, mieszaniny gazowe E","methodology":"Ciepło spalania, Wartość opałowa, Gęstość, gęstość względna, Liczba Wobbego","parameters":[],"technique":"Metoda obliczeniowa na podstawie składu gazu","techniques":["Metoda obliczeniowa na podstawie składu gazu"],"computed":[],"activity":"Ciepło spalania, Wartość opałowa, Gęstość, gęstość względna, Liczba Wobbego\nMetoda obliczeniowa na podstawie składu gazu","reference":"PN-EN ISO 6976","norm_bases":["PN-EN ISO 6976"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gaz ziemny, biogaz, mieszaniny gazowe E Ciepło spalania, Wartość opałowa, Gęstość, gęstość względna, Liczba Wobbego\nMetoda obliczeniowa na podstawie składu gazu PN-EN ISO 6976 Gaz ziemny, biogaz, mieszaniny gazowe E Cieplo spalania, Wartosc opalowa, Gestosc, gestosc wzgledna, Liczba Wobbego\nMetoda obliczeniowa na podstawie skladu gazu PN-EN ISO 6976","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"Gross calorific value, Net calorific value, Density, relative density, Wobbe index","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Natural gas, biogas, gas mixtures E Gross calorific value, Net calorific value, Density, relative density, Wobbe index Calculation method based on gas composition Climate and Resources Protection Laboratory (GE-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 6976","technique_en":"Calculation method based on gas composition","test_object_en":"Natural gas, biogas, gas mixtures E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"天然气、沼气、混合气体 E 燃烧热、低位发热量、密度、相对密度、沃泊指数 依据气体组成的计算法 气候与资源保护实验室（GE-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 6976","lab_section_zh":"气候与资源保护实验室（GE-1）","test_object_zh":"天然气、沼气、混合气体 E","methodology_zh":"燃烧热、低位发热量、密度、相对密度、沃泊指数","technique_zh":"依据气体组成的计算法"},{"_id":"6a7d75f9441eff5f156487df","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz ziemny, biogaz, mieszaniny gazowe E","methodology":"Stężenie węglowodorów alifatycznych C6 – C12","parameters":[{"name":"heksany (0,0001 – 0,5) % (mol/mol)"},{"name":"heptany (0,0001 – 0,5) % (mol/mol)"},{"name":"oktany (0,0001 – 0,2) % (mol/mol)"},{"name":"nonany (0,0001 – 0,1) % (mol/mol)"},{"name":"węglowodory wyższe od nonanów"},{"name":"Zakres","range":"(0,0001 – 0,01) % (mol/mol)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów alifatycznych C6 – C12\nZakres:\nheksany (0,0001 – 0,5) % (mol/mol)\nheptany (0,0001 – 0,5) % (mol/mol)\noktany (0,0001 – 0,2) % (mol/mol)\nnonany (0,0001 – 0,1) % (mol/mol)\nwęglowodory wyższe od nonanów\nZakres (0,0001 – 0,01) % (mol/mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"02/GE-1/22","norm_bases":["02/GE-1/22"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gaz ziemny, biogaz, mieszaniny gazowe E Stężenie węglowodorów alifatycznych C6 – C12\nZakres:\nheksany (0,0001 – 0,5) % (mol/mol)\nheptany (0,0001 – 0,5) % (mol/mol)\noktany (0,0001 – 0,2) % (mol/mol)\nnonany (0,0001 – 0,1) % (mol/mol)\nwęglowodory wyższe od nonanów\nZakres (0,0001 – 0,01) % (mol/mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) 02/GE-1/22 Gaz ziemny, biogaz, mieszaniny gazowe E Stezenie weglowodorow alifatycznych C6 – C12\nZakres:\nheksany (0,0001 – 0,5) % (mol/mol)\nheptany (0,0001 – 0,5) % (mol/mol)\noktany (0,0001 – 0,2) % (mol/mol)\nnonany (0,0001 – 0,1) % (mol/mol)\nweglowodory wyzsze od nonanow\nZakres (0,0001 – 0,01) % (mol/mol)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) 02/GE-1/22","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"Concentration of aliphatic hydrocarbons C6 – C12","parameters_en":[{"name":"hexanes (0,0001 – 0,5) % (mol/mol)"},{"name":"heptanes (0,0001 – 0,5) % (mol/mol)"},{"name":"octanes (0,0001 – 0,2) % (mol/mol)"},{"name":"nonanes (0,0001 – 0,1) % (mol/mol)"},{"name":"hydrocarbons higher than nonanes"},{"name":"Range","range":"(0,0001 – 0,01) % (mol/mol)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Natural gas, biogas, gas mixtures E Concentration of aliphatic hydrocarbons C6 – C12 Gas chromatography with flame ionization detection (GC-FID) Climate and Resources Protection Laboratory (GE-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. hexanes (0,0001 – 0,5) % (mol/mol) heptanes (0,0001 – 0,5) % (mol/mol) octanes (0,0001 – 0,2) % (mol/mol) nonanes (0,0001 – 0,1) % (mol/mol) hydrocarbons higher than nonanes Range 02/GE-1/22","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Natural gas, biogas, gas mixtures E","parameters_zh":[{"name":"heksany (0,0001 – 0,5) % (mol/mol)"},{"name":"heptany (0,0001 – 0,5) % (mol/mol)"},{"name":"oktany (0,0001 – 0,2) % (mol/mol)"},{"name":"nonany (0,0001 – 0,1) % (mol/mol)"},{"name":"węglowodory wyższe od nonanów"},{"name":"范围","range":"(0,0001 – 0,01) % (mol/mol)"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"天然气、沼气、混合气体 E 气相色谱-氢火焰离子化检测法（GC-FID） 气候与资源保护实验室（GE-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 02/GE-1/22","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"气候与资源保护实验室（GE-1）","test_object_zh":"天然气、沼气、混合气体 E"},{"_id":"6a7d75f9441eff5f156487e0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz ziemny, biogaz, mieszaniny gazowe E","methodology":"Stężenie związków siarki","parameters":[{"name":"Siarkowodór"},{"name":"Zakres","range":"(0,00001 – 0,05) % (mol/mol)"},{"name":"merkaptan metylowy (0,00001 – 0,05) % (mol/mol) merkaptan etylowy (0,00001 – 0,05) % (mol/mol) merkaptan propylowy (0,00001 – 0,05) % (mol/mol) merkaptan butylowy (0,00001 – 0,05) % (mol/mol) COS (0,00001 – 0,05) % (mol/mol) CS2 (0,00001 – 0,05) % (mol/mol) siarczek dimetylu (0,00001 – 0,05) % (mol/mol) disiarczek dimetylu (0,00001 – 0,05) % (mol/mol) siarczek metylowo – etylowy (0,00001 – 0,05) % (mol/mol) siarczek dietylu (0,00001 – 0,05) % (mol/mol) disiarczek dietylu (0,00001 – 0,05) % (mol/mol) siarczek dipropylu (0,00001 – 0,05) % (mol/mol)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)"],"computed":[],"activity":"Stężenie związków siarki\nZakres:\nSiarkowodór\nZakres (0,00001 – 0,05) % (mol/mol)\nmerkaptan metylowy (0,00001 – 0,05) % (mol/mol) merkaptan etylowy (0,00001 – 0,05) % (mol/mol) merkaptan propylowy (0,00001 – 0,05) % (mol/mol) merkaptan butylowy (0,00001 – 0,05) % (mol/mol) COS (0,00001 – 0,05) % (mol/mol) CS2 (0,00001 – 0,05) % (mol/mol) siarczek dimetylu (0,00001 – 0,05) % (mol/mol) disiarczek dimetylu (0,00001 – 0,05) % (mol/mol) siarczek metylowo – etylowy (0,00001 – 0,05) % (mol/mol) siarczek dietylu (0,00001 – 0,05) % (mol/mol) disiarczek dietylu (0,00001 – 0,05) % (mol/mol) siarczek dipropylu (0,00001 – 0,05) % (mol/mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)","reference":"01/GE-1/22 | PN-EN ISO 19739","norm_bases":["01/GE-1/22","PN-EN ISO 19739"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gaz ziemny, biogaz, mieszaniny gazowe E Stężenie związków siarki\nZakres:\nSiarkowodór\nZakres (0,00001 – 0,05) % (mol/mol)\nmerkaptan metylowy (0,00001 – 0,05) % (mol/mol) merkaptan etylowy (0,00001 – 0,05) % (mol/mol) merkaptan propylowy (0,00001 – 0,05) % (mol/mol) merkaptan butylowy (0,00001 – 0,05) % (mol/mol) COS (0,00001 – 0,05) % (mol/mol) CS2 (0,00001 – 0,05) % (mol/mol) siarczek dimetylu (0,00001 – 0,05) % (mol/mol) disiarczek dimetylu (0,00001 – 0,05) % (mol/mol) siarczek metylowo – etylowy (0,00001 – 0,05) % (mol/mol) siarczek dietylu (0,00001 – 0,05) % (mol/mol) disiarczek dietylu (0,00001 – 0,05) % (mol/mol) siarczek dipropylu (0,00001 – 0,05) % (mol/mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD) 01/GE-1/22 | PN-EN ISO 19739 Gaz ziemny, biogaz, mieszaniny gazowe E Stezenie zwiazkow siarki\nZakres:\nSiarkowodor\nZakres (0,00001 – 0,05) % (mol/mol)\nmerkaptan metylowy (0,00001 – 0,05) % (mol/mol) merkaptan etylowy (0,00001 – 0,05) % (mol/mol) merkaptan propylowy (0,00001 – 0,05) % (mol/mol) merkaptan butylowy (0,00001 – 0,05) % (mol/mol) COS (0,00001 – 0,05) % (mol/mol) CS2 (0,00001 – 0,05) % (mol/mol) siarczek dimetylu (0,00001 – 0,05) % (mol/mol) disiarczek dimetylu (0,00001 – 0,05) % (mol/mol) siarczek metylowo – etylowy (0,00001 – 0,05) % (mol/mol) siarczek dietylu (0,00001 – 0,05) % (mol/mol) disiarczek dietylu (0,00001 – 0,05) % (mol/mol) siarczek dipropylu (0,00001 – 0,05) % (mol/mol)\nMetoda chromatografii gazowej z detekcja plomieniowo-fotometryczna (GC-FPD) 01/GE-1/22 | PN-EN ISO 19739","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"Concentration of sulphur compounds","parameters_en":[{"name":"Hydrogen sulfide"},{"name":"Range","range":"(0,00001 – 0,05) % (mol/mol)"},{"name":"methyl mercaptan (0,00001 – 0,05) % (mol/mol) ethyl mercaptan (0,00001 – 0,05) % (mol/mol) propyl mercaptan (0,00001 – 0,05) % (mol/mol) butyl mercaptan (0,00001 – 0,05) % (mol/mol) COS (0,00001 – 0,05) % (mol/mol) CS2 (0,00001 – 0,05) % (mol/mol) dimethyl sulphide (0,00001 – 0,05) % (mol/mol) dimethyl disulphide (0,00001 – 0,05) % (mol/mol) methyl ethyl sulphide (0,00001 – 0,05) % (mol/mol) diethyl sulphide (0,00001 – 0,05) % (mol/mol) diethyl disulphide (0,00001 – 0,05) % (mol/mol) dipropyl sulphide (0,00001 – 0,05) % (mol/mol)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Natural gas, biogas, gas mixtures E Concentration of sulphur compounds Gas chromatography with flame photometric detection (GC-FPD) Climate and Resources Protection Laboratory (GE-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Hydrogen sulfide Range methyl mercaptan (0,00001 – 0,05) % (mol/mol) ethyl mercaptan (0,00001 – 0,05) % (mol/mol) propyl mercaptan (0,00001 – 0,05) % (mol/mol) butyl mercaptan (0,00001 – 0,05) % (mol/mol) COS (0,00001 – 0,05) % (mol/mol) CS2 (0,00001 – 0,05) % (mol/mol) dimethyl sulphide (0,00001 – 0,05) % (mol/mol) dimethyl disulphide (0,00001 – 0,05) % (mol/mol) methyl ethyl sulphide (0,00001 – 0,05) % (mol/mol) diethyl sulphide (0,00001 – 0,05) % (mol/mol) diethyl disulphide (0,00001 – 0,05) % (mol/mol) dipropyl sulphide (0,00001 – 0,05) % (mol/mol) 01/GE-1/22 | PN-EN ISO 19739","technique_en":"Gas chromatography with flame photometric detection (GC-FPD)","test_object_en":"Natural gas, biogas, gas mixtures E","parameters_zh":[{"name":"硫化氢"},{"name":"范围","range":"(0,00001 – 0,05) % (mol/mol)"},{"name":"merkaptan metylowy (0,00001 – 0,05) % (mol/mol) merkaptan etylowy (0,00001 – 0,05) % (mol/mol) merkaptan propylowy (0,00001 – 0,05) % (mol/mol) merkaptan butylowy (0,00001 – 0,05) % (mol/mol) COS (0,00001 – 0,05) % (mol/mol) CS2 (0,00001 – 0,05) % (mol/mol) siarczek dimetylu (0,00001 – 0,05) % (mol/mol) disiarczek dimetylu (0,00001 – 0,05) % (mol/mol) siarczek metylowo – etylowy (0,00001 – 0,05) % (mol/mol) siarczek dietylu (0,00001 – 0,05) % (mol/mol) disiarczek dietylu (0,00001 – 0,05) % (mol/mol) siarczek dipropylu (0,00001 – 0,05) % (mol/mol)"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"天然气、沼气、混合气体 E 气相色谱-火焰光度检测法（GC-FPD） 气候与资源保护实验室（GE-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 硫化氢 范围 01/GE-1/22 | PN-EN ISO 19739","lab_section_zh":"气候与资源保护实验室（GE-1）","technique_zh":"气相色谱-火焰光度检测法（GC-FPD）","test_object_zh":"天然气、沼气、混合气体 E"},{"_id":"6a7d75f9441eff5f156487e1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz ziemny, mieszaniny gazowe, powietrze E","methodology":"Punkt rosy wody","parameters":[{"name":"Zakres","range":"(-30 – +20) °C"}],"technique":"Metoda z czujnikiem pojemnościowym","techniques":["Metoda z czujnikiem pojemnościowym"],"computed":[],"activity":"Punkt rosy wody\nZakres (-30 – +20) °C\nMetoda z czujnikiem pojemnościowym","reference":"05/GE-1/22","norm_bases":["05/GE-1/22"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gaz ziemny, mieszaniny gazowe, powietrze E Punkt rosy wody\nZakres (-30 – +20) °C\nMetoda z czujnikiem pojemnościowym 05/GE-1/22 Gaz ziemny, mieszaniny gazowe, powietrze E Punkt rosy wody\nZakres (-30 – +20) °C\nMetoda z czujnikiem pojemnosciowym 05/GE-1/22","categories":["water","environment","petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"Water dew point","parameters_en":[{"name":"Range","range":"(-30 – +20) °C"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Natural gas, gas mixtures, air E Water dew point Method with a capacitive sensor Climate and Resources Protection Laboratory (GE-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range 05/GE-1/22","technique_en":"Method with a capacitive sensor","test_object_en":"Natural gas, gas mixtures, air E","parameters_zh":[{"name":"范围","range":"(-30 – +20) °C"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"气候与资源保护实验室（GE-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 05/GE-1/22","lab_section_zh":"气候与资源保护实验室（GE-1）"},{"_id":"6a7d75f9441eff5f156487e2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz rafineryjny, gaz ziemny, mieszaniny gazowe E","methodology":"Stężenie węglowodorów C1 – C5, C6+","parameters":[{"name":"metan (0,001 – 100) % (mol/mol)"},{"name":"etan (0,001 – 100) % (mol/mol)"},{"name":"eten (0,001 – 100) % (mol/mol)"},{"name":"propan (0,001 – 100) % (mol/mol)"},{"name":"propen (0,001 – 100) % (mol/mol)"},{"name":"butany (0,001 – 100) % (mol/mol)"},{"name":"buteny (0,001 – 100) % (mol/mol)"},{"name":"1,3 butadien"},{"name":"Zakres","range":"(0,001 – 100) % (mol/mol)"},{"name":"pentany (0,001 – 0,5) % (mol/mol)"},{"name":"C6+ (0,001 – 5) % (mol/mol)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie węglowodorów C1 – C5, C6+\nZakres:\nmetan (0,001 – 100) % (mol/mol)\netan (0,001 – 100) % (mol/mol)\neten (0,001 – 100) % (mol/mol)\npropan (0,001 – 100) % (mol/mol)\npropen (0,001 – 100) % (mol/mol)\nbutany (0,001 – 100) % (mol/mol)\nbuteny (0,001 – 100) % (mol/mol)\n1,3 butadien\nZakres (0,001 – 100) % (mol/mol)\npentany (0,001 – 0,5) % (mol/mol)\nC6+ (0,001 – 5) % (mol/mol)","reference":"04/GE-1/22","norm_bases":["04/GE-1/22"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gaz rafineryjny, gaz ziemny, mieszaniny gazowe E Stężenie węglowodorów C1 – C5, C6+\nZakres:\nmetan (0,001 – 100) % (mol/mol)\netan (0,001 – 100) % (mol/mol)\neten (0,001 – 100) % (mol/mol)\npropan (0,001 – 100) % (mol/mol)\npropen (0,001 – 100) % (mol/mol)\nbutany (0,001 – 100) % (mol/mol)\nbuteny (0,001 – 100) % (mol/mol)\n1,3 butadien\nZakres (0,001 – 100) % (mol/mol)\npentany (0,001 – 0,5) % (mol/mol)\nC6+ (0,001 – 5) % (mol/mol) 04/GE-1/22 Gaz rafineryjny, gaz ziemny, mieszaniny gazowe E Stezenie weglowodorow C1 – C5, C6+\nZakres:\nmetan (0,001 – 100) % (mol/mol)\netan (0,001 – 100) % (mol/mol)\neten (0,001 – 100) % (mol/mol)\npropan (0,001 – 100) % (mol/mol)\npropen (0,001 – 100) % (mol/mol)\nbutany (0,001 – 100) % (mol/mol)\nbuteny (0,001 – 100) % (mol/mol)\n1,3 butadien\nZakres (0,001 – 100) % (mol/mol)\npentany (0,001 – 0,5) % (mol/mol)\nC6+ (0,001 – 5) % (mol/mol) 04/GE-1/22","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"Concentration of C1 – C5, C6+ hydrocarbons","parameters_en":[{"name":"methane (0,001 – 100) % (mol/mol)"},{"name":"ethane (0,001 – 100) % (mol/mol)"},{"name":"ethene (0,001 – 100) % (mol/mol)"},{"name":"propane (0,001 – 100) % (mol/mol)"},{"name":"propene (0,001 – 100) % (mol/mol)"},{"name":"butanes (0,001 – 100) % (mol/mol)"},{"name":"butenes (0,001 – 100) % (mol/mol)"},{"name":"1,3 butadiene"},{"name":"Range","range":"(0,001 – 100) % (mol/mol)"},{"name":"pentanes (0,001 – 0,5) % (mol/mol)"},{"name":"C6+ (0,001 – 5) % (mol/mol)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Refinery gas, natural gas, gas mixtures E Concentration of C1 – C5, C6+ hydrocarbons Climate and Resources Protection Laboratory (GE-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. methane (0,001 – 100) % (mol/mol) ethane (0,001 – 100) % (mol/mol) ethene (0,001 – 100) % (mol/mol) propane (0,001 – 100) % (mol/mol) propene (0,001 – 100) % (mol/mol) butanes (0,001 – 100) % (mol/mol) butenes (0,001 – 100) % (mol/mol) 1,3 butadiene Range pentanes (0,001 – 0,5) % (mol/mol) C6+ (0,001 – 5) % (mol/mol) 04/GE-1/22","test_object_en":"Refinery gas, natural gas, gas mixtures E","parameters_zh":[{"name":"metan (0,001 – 100) % (mol/mol)"},{"name":"etan (0,001 – 100) % (mol/mol)"},{"name":"eten (0,001 – 100) % (mol/mol)"},{"name":"propan (0,001 – 100) % (mol/mol)"},{"name":"propen (0,001 – 100) % (mol/mol)"},{"name":"butany (0,001 – 100) % (mol/mol)"},{"name":"buteny (0,001 – 100) % (mol/mol)"},{"name":"1,3 butadien"},{"name":"范围","range":"(0,001 – 100) % (mol/mol)"},{"name":"pentany (0,001 – 0,5) % (mol/mol)"},{"name":"C6+ (0,001 – 5) % (mol/mol)"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"炼厂气、天然气、混合气体 E 气候与资源保护实验室（GE-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 04/GE-1/22","lab_section_zh":"气候与资源保护实验室（GE-1）","test_object_zh":"炼厂气、天然气、混合气体 E"},{"_id":"6a7d75f9441eff5f156487e3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz rafineryjny, gaz ziemny, mieszaniny gazowe E","methodology":"Stężenie N2, CO2, He, H2, O2, CO","parameters":[{"name":"N2 (0,005 – 100) % (mol/mol)"},{"name":"CO2 (0,005 – 100) % (mol/mol)"},{"name":"He (0,005 – 100) % (mol/mol)"},{"name":"H2 (0,005 – 100) % (mol/mol)"},{"name":"O2 (0,005 – 100) % (mol/mol)"},{"name":"CO (0,005 – 100) % (mol/mol)"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną i płomieniowo-jonizacyjną (GC-TCD, FID)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną i płomieniowo-jonizacyjną (GC-TCD, FID)"],"computed":[],"activity":"Stężenie N2, CO2, He, H2, O2, CO\nZakres:\nN2 (0,005 – 100) % (mol/mol)\nCO2 (0,005 – 100) % (mol/mol)\nHe (0,005 – 100) % (mol/mol)\nH2 (0,005 – 100) % (mol/mol)\nO2 (0,005 – 100) % (mol/mol)\nCO (0,005 – 100) % (mol/mol)\nMetoda chromatografii gazowej z detekcją termokonduktometryczną i płomieniowo-jonizacyjną (GC-TCD, FID)","reference":"04/GE-1/22","norm_bases":["04/GE-1/22"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gaz rafineryjny, gaz ziemny, mieszaniny gazowe E Stężenie N2, CO2, He, H2, O2, CO\nZakres:\nN2 (0,005 – 100) % (mol/mol)\nCO2 (0,005 – 100) % (mol/mol)\nHe (0,005 – 100) % (mol/mol)\nH2 (0,005 – 100) % (mol/mol)\nO2 (0,005 – 100) % (mol/mol)\nCO (0,005 – 100) % (mol/mol)\nMetoda chromatografii gazowej z detekcją termokonduktometryczną i płomieniowo-jonizacyjną (GC-TCD, FID) 04/GE-1/22 Gaz rafineryjny, gaz ziemny, mieszaniny gazowe E Stezenie N2, CO2, He, H2, O2, CO\nZakres:\nN2 (0,005 – 100) % (mol/mol)\nCO2 (0,005 – 100) % (mol/mol)\nHe (0,005 – 100) % (mol/mol)\nH2 (0,005 – 100) % (mol/mol)\nO2 (0,005 – 100) % (mol/mol)\nCO (0,005 – 100) % (mol/mol)\nMetoda chromatografii gazowej z detekcja termokonduktometryczna i plomieniowo-jonizacyjna (GC-TCD, FID) 04/GE-1/22","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"N2, CO2, He, H2, O2, CO concentration","parameters_en":[{"name":"N2 (0,005 – 100) % (mol/mol)"},{"name":"CO2 (0,005 – 100) % (mol/mol)"},{"name":"He (0,005 – 100) % (mol/mol)"},{"name":"H2 (0,005 – 100) % (mol/mol)"},{"name":"O2 (0,005 – 100) % (mol/mol)"},{"name":"CO (0,005 – 100) % (mol/mol)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Refinery gas, natural gas, gas mixtures E N2, CO2, He, H2, O2, CO concentration Gas chromatography with thermal conductivity and flame ionization detection (GC-TCD, FID) Climate and Resources Protection Laboratory (GE-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. N2 (0,005 – 100) % (mol/mol) CO2 (0,005 – 100) % (mol/mol) He (0,005 – 100) % (mol/mol) H2 (0,005 – 100) % (mol/mol) O2 (0,005 – 100) % (mol/mol) CO (0,005 – 100) % (mol/mol) 04/GE-1/22","technique_en":"Gas chromatography with thermal conductivity and flame ionization detection (GC-TCD, FID)","test_object_en":"Refinery gas, natural gas, gas mixtures E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"炼厂气、天然气、混合气体 E 气候与资源保护实验室（GE-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 04/GE-1/22","lab_section_zh":"气候与资源保护实验室（GE-1）","test_object_zh":"炼厂气、天然气、混合气体 E"},{"_id":"6a7d75f9441eff5f156487e4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gaz rafineryjny, gaz ziemny, mieszaniny gazowe E","methodology":"Ciepło spalania, Wartość opałowa, Gęstość, gęstość względna, Liczba Wobbego","parameters":[],"technique":"Metoda obliczeniowa na podstawie składu gazu","techniques":["Metoda obliczeniowa na podstawie składu gazu"],"computed":[],"activity":"Ciepło spalania, Wartość opałowa, Gęstość, gęstość względna, Liczba Wobbego\nMetoda obliczeniowa na podstawie składu gazu","reference":"PN-EN ISO 6976","norm_bases":["PN-EN ISO 6976"],"lab_section":"Laboratorium Ochrony Klimatu i Zasobów (GE-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gaz rafineryjny, gaz ziemny, mieszaniny gazowe E Ciepło spalania, Wartość opałowa, Gęstość, gęstość względna, Liczba Wobbego\nMetoda obliczeniowa na podstawie składu gazu PN-EN ISO 6976 Gaz rafineryjny, gaz ziemny, mieszaniny gazowe E Cieplo spalania, Wartosc opalowa, Gestosc, gestosc wzgledna, Liczba Wobbego\nMetoda obliczeniowa na podstawie skladu gazu PN-EN ISO 6976","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Climate and Resources Protection Laboratory (GE-1)","methodology_en":"Gross calorific value, Net calorific value, Density, relative density, Wobbe index","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Refinery gas, natural gas, gas mixtures E Gross calorific value, Net calorific value, Density, relative density, Wobbe index Calculation method based on gas composition Climate and Resources Protection Laboratory (GE-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 6976","technique_en":"Calculation method based on gas composition","test_object_en":"Refinery gas, natural gas, gas mixtures E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"炼厂气、天然气、混合气体 E 燃烧热、低位发热量、密度、相对密度、沃泊指数 依据气体组成的计算法 气候与资源保护实验室（GE-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 6976","lab_section_zh":"气候与资源保护实验室（GE-1）","methodology_zh":"燃烧热、低位发热量、密度、相对密度、沃泊指数","technique_zh":"依据气体组成的计算法","test_object_zh":"炼厂气、天然气、混合气体 E"},{"_id":"6a7d75f9441eff5f156487e5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe","methodology":"Błędy wskazań, strata ciśnienia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Błędy wskazań, strata ciśnienia","reference":"Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. 2008 nr 18 poz. 115)","norm_bases":["Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. 2008 nr 18 poz. 115)"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe Błędy wskazań, strata ciśnienia Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. 2008 nr 18 poz. 115) Gazomierze miechowe Bledy wskazan, strata cisnienia Rozporzadzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. 2008 nr 18 poz. 115)","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Errors of indication, pressure loss","search_en":"Diaphragm gas meters Errors of indication, pressure loss Flow Metrology Laboratory (GM-1) Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. 2008 nr 18 poz. 115)","test_object_en":"Diaphragm gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"流量计量实验室（GM-1） Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. 2008 nr 18 poz. 115)"},{"_id":"6a7d75f9441eff5f156487e6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Części złączne do instalacji gazowych","methodology":"Wymiary geometryczne liniowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-79/M-54840 p.4.3.2","norm_bases":["PN-79/M-54840 p.4.3.2"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Części złączne do instalacji gazowych Wymiary geometryczne liniowe PN-79/M-54840 p.4.3.2 Czesci zlaczne do instalacji gazowych Wymiary geometryczne liniowe PN-79/M-54840 p.4.3.2","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Linear geometric dimensions","search_en":"Connecting components for gas installations Linear geometric dimensions Flow Metrology Laboratory (GM-1) PN-79/M-54840 p.4.3.2","test_object_en":"Connecting components for gas installations","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"几何线性尺寸 流量计量实验室（GM-1） PN-79/M-54840 p.4.3.2","methodology_zh":"几何线性尺寸"},{"_id":"6a7d75f9441eff5f156487e7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe, termiczne masowe","methodology":"Właściwości metrologiczne","parameters":[{"name":"błąd wskazania"},{"name":"odtwarzalność metrologiczna"},{"name":"powtarzalność metrologiczna"},{"name":"trwałość"},{"name":"wpływ wibracji"},{"name":"odporność na upadek Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm Zakres temperatur:","range":"(-40 – +70) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości metrologiczne\nZakres:\nbłąd wskazania\nodtwarzalność metrologiczna\npowtarzalność metrologiczna\ntrwałość\nwpływ wibracji\nodporność na upadek Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm Zakres temperatur: (-40 – +70) °C","reference":"OIML R 137-1&2:2012 p.12.6.1; 12.6.2; 12.6.3; 12.6.9; 12.6.13; A.5.1; A.5.2","norm_bases":["OIML R 137-1&2:2012 p.12.6.1; 12.6.2; 12.6.3; 12.6.9; 12.6.13; A.5.1; A.5.2"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe, termiczne masowe Właściwości metrologiczne\nZakres:\nbłąd wskazania\nodtwarzalność metrologiczna\npowtarzalność metrologiczna\ntrwałość\nwpływ wibracji\nodporność na upadek Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm Zakres temperatur: (-40 – +70) °C OIML R 137-1&2:2012 p.12.6.1; 12.6.2; 12.6.3; 12.6.9; 12.6.13; A.5.1; A.5.2 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe, termiczne masowe Wlasciwosci metrologiczne\nZakres:\nblad wskazania\nodtwarzalnosc metrologiczna\npowtarzalnosc metrologiczna\ntrwalosc\nwplyw wibracji\nodpornosc na upadek Zakres strumienia objetosci: (0,015 – 1 000) m3/h\nMaksymalna srednica nominalna: DNmax = 200 mm Zakres temperatur: (-40 – +70) °C OIML R 137-1&2:2012 p.12.6.1; 12.6.2; 12.6.3; 12.6.9; 12.6.13; A.5.1; A.5.2","categories":["metrology"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Metrological properties","parameters_en":[{"name":"indication error"},{"name":"metrological reproducibility"},{"name":"metrological repeatability"},{"name":"durability"},{"name":"effect of vibration"},{"name":"drop resistance Volume flow range:","range":"(0,015 – 1 000) m3/h"},{"name":"Maximum nominal diameter: DNmax = 200 mm Temperature range:","range":"(-40 – +70) °C"}],"search_en":"Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters Metrological properties Flow Metrology Laboratory (GM-1) indication error metrological reproducibility metrological repeatability durability effect of vibration drop resistance Volume flow range: Maximum nominal diameter: DNmax = 200 mm Temperature range: OIML R 137-1&2:2012 p.12.6.1; 12.6.2; 12.6.3; 12.6.9; 12.6.13; A.5.1; A.5.2","test_object_en":"Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"膜式、涡轮式、腰轮式、超声波与热式质量燃气表 计量性能 流量计量实验室（GM-1） 示值误差 耐久性 振动影响 OIML R 137-1&2:2012 p.12.6.1; 12.6.2; 12.6.3; 12.6.9; 12.6.13; A.5.1; A.5.2","parameters_zh":[{"name":"示值误差"},{"name":"odtwarzalność metrologiczna"},{"name":"powtarzalność metrologiczna"},{"name":"耐久性"},{"name":"振动影响"},{"name":"odporność na upadek Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm Zakres temperatur:","range":"(-40 – +70) °C"}],"methodology_zh":"计量性能","test_object_zh":"膜式、涡轮式、腰轮式、超声波与热式质量燃气表"},{"_id":"6a7d75f9441eff5f156487e8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe, termiczne masowe","methodology":"Wpływ temperatury na właściwości metrologiczne, Zakres strumienia objętości: (0,015 – 160) m3/h, Zakres temperatur: (-40 – +70) °C, Maksymalna średnica nominalna: DNmax = 80 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ temperatury na właściwości metrologiczne, Zakres strumienia objętości: (0,015 – 160) m3/h, Zakres temperatur: (-40 – +70) °C, Maksymalna średnica nominalna: DNmax = 80 mm","reference":"OIML R 137-1&2:2012 p. 12.6.7;","norm_bases":["OIML R 137-1&2:2012 p. 12.6.7;"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe, termiczne masowe Wpływ temperatury na właściwości metrologiczne, Zakres strumienia objętości: (0,015 – 160) m3/h, Zakres temperatur: (-40 – +70) °C, Maksymalna średnica nominalna: DNmax = 80 mm OIML R 137-1&2:2012 p. 12.6.7; Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe, termiczne masowe Wplyw temperatury na wlasciwosci metrologiczne, Zakres strumienia objetosci: (0,015 – 160) m3/h, Zakres temperatur: (-40 – +70) °C, Maksymalna srednica nominalna: DNmax = 80 mm OIML R 137-1&2:2012 p. 12.6.7;","categories":["metrology"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of temperature on metrological properties, Volume flow rate range: (0,015 – 160) m3/h, Temperature range: (-40 – +70) °C, Maximum nominal diameter: DNmax = 80 mm","search_en":"Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters Effect of temperature on metrological properties, Volume flow rate range: (0,015 – 160) m3/h, Temperature range: (-40 – +70) °C, Maximum nominal diameter: DNmax = 80 mm Flow Metrology Laboratory (GM-1) OIML R 137-1&2:2012 p. 12.6.7;","test_object_en":"Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"膜式、涡轮式、腰轮式、超声波与热式质量燃气表 流量计量实验室（GM-1） OIML R 137-1&2:2012 p. 12.6.7;","test_object_zh":"膜式、涡轮式、腰轮式、超声波与热式质量燃气表"},{"_id":"6a7d75f9441eff5f156487e9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe, termiczne masowe","methodology":"Szczelność obudowy, Maksymalne ciśnienie robocze: 20 bar","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność obudowy, Maksymalne ciśnienie robocze: 20 bar","reference":"OIML R 137-1&2:2012 p. 6.1.2","norm_bases":["OIML R 137-1&2:2012 p. 6.1.2"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe, termiczne masowe Szczelność obudowy, Maksymalne ciśnienie robocze: 20 bar OIML R 137-1&2:2012 p. 6.1.2 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe, termiczne masowe Szczelnosc obudowy, Maksymalne cisnienie robocze: 20 bar OIML R 137-1&2:2012 p. 6.1.2","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Enclosure tightness, Maximum working pressure: 20 bar","search_en":"Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters Enclosure tightness, Maximum working pressure: 20 bar Flow Metrology Laboratory (GM-1) OIML R 137-1&2:2012 p. 6.1.2","test_object_en":"Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"膜式、涡轮式、腰轮式、超声波与热式质量燃气表 流量计量实验室（GM-1） OIML R 137-1&2:2012 p. 6.1.2","test_object_zh":"膜式、涡轮式、腰轮式、超声波与热式质量燃气表"},{"_id":"6a7d75f9441eff5f156487ea","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe, termiczne masowe","methodology":"Cechy konstrukcyjne","parameters":[{"name":"wymiary konstrukcyjne elementów liczydła"},{"name":"sprawdzenie objętości cyklicznej"},{"name":"sprawdzenie wartości impulsu nadajnika impulsów"},{"name":"przyrost wskazania elementu kontrolnego"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy konstrukcyjne\nZakres:\nwymiary konstrukcyjne elementów liczydła\nsprawdzenie objętości cyklicznej\nsprawdzenie wartości impulsu nadajnika impulsów\nprzyrost wskazania elementu kontrolnego","reference":"OIML R 137-1&2:2012, 6.3.4; 6.4.2; 6.4.3; 6.4.5","norm_bases":["OIML R 137-1&2:2012, 6.3.4; 6.4.2; 6.4.3; 6.4.5"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe, termiczne masowe Cechy konstrukcyjne\nZakres:\nwymiary konstrukcyjne elementów liczydła\nsprawdzenie objętości cyklicznej\nsprawdzenie wartości impulsu nadajnika impulsów\nprzyrost wskazania elementu kontrolnego OIML R 137-1&2:2012, 6.3.4; 6.4.2; 6.4.3; 6.4.5 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe, termiczne masowe Cechy konstrukcyjne\nZakres:\nwymiary konstrukcyjne elementow liczydla\nsprawdzenie objetosci cyklicznej\nsprawdzenie wartosci impulsu nadajnika impulsow\nprzyrost wskazania elementu kontrolnego OIML R 137-1&2:2012, 6.3.4; 6.4.2; 6.4.3; 6.4.5","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Design features","parameters_en":[{"name":"design dimensions of the counter components"},{"name":"checking of the cyclic volume"},{"name":"checking of the pulse value of the pulse transmitter"},{"name":"increase in the indication of the control element"}],"search_en":"Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters Design features Flow Metrology Laboratory (GM-1) design dimensions of the counter components checking of the cyclic volume checking of the pulse value of the pulse transmitter increase in the indication of the control element OIML R 137-1&2:2012, 6.3.4; 6.4.2; 6.4.3; 6.4.5","test_object_en":"Diaphragm, turbine, rotary, ultrasonic and thermal mass gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"膜式、涡轮式、腰轮式、超声波与热式质量燃气表 流量计量实验室（GM-1） OIML R 137-1&2:2012, 6.3.4; 6.4.2; 6.4.3; 6.4.5","test_object_zh":"膜式、涡轮式、腰轮式、超声波与热式质量燃气表"},{"_id":"6a7d75f9441eff5f156487eb","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe wyposażone w urządzenia elektroniczne (liczydła), Gazomierze ultradźwiękowe, termiczne masowe","methodology":"Próby eksploatacyjne – zasilanie bateryjne","parameters":[{"name":"niskie napięcie z akumulatora wewnętrznego Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Próby eksploatacyjne – zasilanie bateryjne\nZakres:\nniskie napięcie z akumulatora wewnętrznego Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm","reference":"OIML R 137-1&2:2012 p.A.8","norm_bases":["OIML R 137-1&2:2012 p.A.8"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe wyposażone w urządzenia elektroniczne (liczydła), Gazomierze ultradźwiękowe, termiczne masowe Próby eksploatacyjne – zasilanie bateryjne\nZakres:\nniskie napięcie z akumulatora wewnętrznego Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p.A.8 Gazomierze miechowe, turbinowe, rotorowe wyposazone w urzadzenia elektroniczne (liczydla), Gazomierze ultradzwiekowe, termiczne masowe Proby eksploatacyjne – zasilanie bateryjne\nZakres:\nniskie napiecie z akumulatora wewnetrznego Zakres strumienia objetosci: (0,015 – 1 000) m3/h\nMaksymalna srednica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p.A.8","categories":["electronics"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Operational tests – battery power supply","parameters_en":[{"name":"low voltage from the internal battery Volume flow range:","range":"(0,015 – 1 000) m3/h"},{"name":"Maximum nominal diameter: DNmax = 200 mm"}],"search_en":"Diaphragm, turbine and rotary gas meters equipped with electronic devices (index units), Ultrasonic and thermal mass gas meters Operational tests – battery power supply Flow Metrology Laboratory (GM-1) low voltage from the internal battery Volume flow range: Maximum nominal diameter: DNmax = 200 mm OIML R 137-1&2:2012 p.A.8","test_object_en":"Diaphragm, turbine and rotary gas meters equipped with electronic devices (index units), Ultrasonic and thermal mass gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"配有电子装置（计数器）的膜式、涡轮式、腰轮式燃气表；超声波与热式质量燃气表 流量计量实验室（GM-1） 最大公称直径：DNmax = 200 mm OIML R 137-1&2:2012 p.A.8","parameters_zh":[{"name":"niskie napięcie z akumulatora wewnętrznego Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"最大公称直径：DNmax = 200 mm"}],"test_object_zh":"配有电子装置（计数器）的膜式、涡轮式、腰轮式燃气表；超声波与热式质量燃气表"},{"_id":"6a7d75f9441eff5f156487ec","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe","methodology":"Środowiska klimatyczne:","parameters":[{"name":"odporność na wilgoć"},{"name":"wpływ wibracji"}],"technique":null,"techniques":[],"computed":[],"activity":"Środowiska klimatyczne:\nZakres:\nodporność na wilgoć\nwpływ wibracji","reference":"PN-EN 16314:2013-11E 4.9.2.2 b) 4.9.5","norm_bases":["PN-EN 16314:2013-11E 4.9.2.2 b) 4.9.5"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe Środowiska klimatyczne:\nZakres:\nodporność na wilgoć\nwpływ wibracji PN-EN 16314:2013-11E 4.9.2.2 b) 4.9.5 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe Srodowiska klimatyczne:\nZakres:\nodpornosc na wilgoc\nwplyw wibracji PN-EN 16314:2013-11E 4.9.2.2 b) 4.9.5","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Climatic environments:","parameters_en":[{"name":"resistance to moisture"},{"name":"effect of vibration"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm, turbine, rotary and ultrasonic gas meters Climatic environments: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. resistance to moisture effect of vibration PN-EN 16314:2013-11E 4.9.2.2 b) 4.9.5","test_object_en":"Diaphragm, turbine, rotary and ultrasonic gas meters","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式、涡轮式、腰轮式与超声波燃气表 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 振动影响 PN-EN 16314:2013-11E 4.9.2.2 b) 4.9.5","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式、涡轮式、腰轮式与超声波燃气表","parameters_zh":[{"name":"odporność na wilgoć"},{"name":"振动影响"}]},{"_id":"6a7d75f9441eff5f156487ed","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe","methodology":"Odporność na zaburzenia elektromagnetyczne:","parameters":[{"name":"trwałe pole magnetyczne"},{"name":"wyładowania elektrostatyczne"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zaburzenia elektromagnetyczne:\nZakres:\ntrwałe pole magnetyczne\nwyładowania elektrostatyczne","reference":"PN-EN 16314:2013-11E 4.12.2 4.12.3","norm_bases":["PN-EN 16314:2013-11E 4.12.2 4.12.3"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe Odporność na zaburzenia elektromagnetyczne:\nZakres:\ntrwałe pole magnetyczne\nwyładowania elektrostatyczne PN-EN 16314:2013-11E 4.12.2 4.12.3 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe Odpornosc na zaburzenia elektromagnetyczne:\nZakres:\ntrwale pole magnetyczne\nwyladowania elektrostatyczne PN-EN 16314:2013-11E 4.12.2 4.12.3","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Immunity to electromagnetic disturbances:","parameters_en":[{"name":"permanent magnetic field"},{"name":"electrostatic discharge"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm, turbine, rotary and ultrasonic gas meters Immunity to electromagnetic disturbances: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. permanent magnetic field electrostatic discharge PN-EN 16314:2013-11E 4.12.2 4.12.3","test_object_en":"Diaphragm, turbine, rotary and ultrasonic gas meters","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式、涡轮式、腰轮式与超声波燃气表 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 静电放电 PN-EN 16314:2013-11E 4.12.2 4.12.3","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式、涡轮式、腰轮式与超声波燃气表","parameters_zh":[{"name":"trwałe pole magnetyczne"},{"name":"静电放电"}]},{"_id":"6a7d75f9441eff5f156487ee","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe","methodology":"Odporność na niewłaściwe postępowanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na niewłaściwe postępowanie","reference":"PN-EN 16314:2013-11E p. 4.14","norm_bases":["PN-EN 16314:2013-11E p. 4.14"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe Odporność na niewłaściwe postępowanie PN-EN 16314:2013-11E p. 4.14 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe Odpornosc na niewlasciwe postepowanie PN-EN 16314:2013-11E p. 4.14","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to mishandling","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm, turbine, rotary and ultrasonic gas meters Resistance to mishandling Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 16314:2013-11E p. 4.14","test_object_en":"Diaphragm, turbine, rotary and ultrasonic gas meters","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式、涡轮式、腰轮式与超声波燃气表 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 16314:2013-11E p. 4.14","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式、涡轮式、腰轮式与超声波燃气表"},{"_id":"6a7d75f9441eff5f156487ef","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe","methodology":"Oporność na temperaturę składowania, Zakres temperatur: (-40 – +70) °C","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Oporność na temperaturę składowania, Zakres temperatur: (-40 – +70) °C","reference":"PN-EN 16314:2013-11E p.4.15","norm_bases":["PN-EN 16314:2013-11E p.4.15"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe Oporność na temperaturę składowania, Zakres temperatur: (-40 – +70) °C PN-EN 16314:2013-11E p.4.15 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe Opornosc na temperature skladowania, Zakres temperatur: (-40 – +70) °C PN-EN 16314:2013-11E p.4.15","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Storage temperature resistance, Temperature range: (-40 – +70) °C","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm, turbine, rotary and ultrasonic gas meters Storage temperature resistance, Temperature range: (-40 – +70) °C Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 16314:2013-11E p.4.15","test_object_en":"Diaphragm, turbine, rotary and ultrasonic gas meters","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式、涡轮式、腰轮式与超声波燃气表 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 16314:2013-11E p.4.15","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式、涡轮式、腰轮式与超声波燃气表"},{"_id":"6a7d75f9441eff5f156487f0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe","methodology":"Badanie starzenia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie starzenia","reference":"PN-EN 16314:2013-11E p. 4.16","norm_bases":["PN-EN 16314:2013-11E p. 4.16"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe Badanie starzenia PN-EN 16314:2013-11E p. 4.16 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe Badanie starzenia PN-EN 16314:2013-11E p. 4.16","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Ageing test","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm, turbine, rotary and ultrasonic gas meters Ageing test Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 16314:2013-11E p. 4.16","test_object_en":"Diaphragm, turbine, rotary and ultrasonic gas meters","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式、涡轮式、腰轮式与超声波燃气表 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 16314:2013-11E p. 4.16","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式、涡轮式、腰轮式与超声波燃气表"},{"_id":"6a7d75f9441eff5f156487f1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe","methodology":"Układ zasilania:","parameters":[{"name":"wymiana baterii"},{"name":"przerwy napięcia"},{"name":"napięcie robocze"}],"technique":null,"techniques":[],"computed":[],"activity":"Układ zasilania:\nZakres:\nwymiana baterii\nprzerwy napięcia\nnapięcie robocze","reference":"PN-EN 16314:2013-11E 6.5 6.7 6.8","norm_bases":["PN-EN 16314:2013-11E 6.5 6.7 6.8"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe Układ zasilania:\nZakres:\nwymiana baterii\nprzerwy napięcia\nnapięcie robocze PN-EN 16314:2013-11E 6.5 6.7 6.8 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe Uklad zasilania:\nZakres:\nwymiana baterii\nprzerwy napiecia\nnapiecie robocze PN-EN 16314:2013-11E 6.5 6.7 6.8","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Power supply system:","parameters_en":[{"name":"battery replacement"},{"name":"voltage interruptions"},{"name":"operating voltage"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm, turbine, rotary and ultrasonic gas meters Power supply system: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. battery replacement voltage interruptions operating voltage PN-EN 16314:2013-11E 6.5 6.7 6.8","test_object_en":"Diaphragm, turbine, rotary and ultrasonic gas meters","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式、涡轮式、腰轮式与超声波燃气表 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 16314:2013-11E 6.5 6.7 6.8","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式、涡轮式、腰轮式与超声波燃气表"},{"_id":"6a7d75f9441eff5f156487f2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe","methodology":"Funkcjonalności dodatkowe","parameters":[{"name":"wpływ metrologiczny"},{"name":"trwałość zaworu"},{"name":"odporność zaworu na zanieczyszczenia w gazie"},{"name":"pamięć nieulotna"},{"name":"trwałość liczydła elektronicznego"}],"technique":null,"techniques":[],"computed":[],"activity":"Funkcjonalności dodatkowe\nZakres:\nwpływ metrologiczny\ntrwałość zaworu\nodporność zaworu na zanieczyszczenia w gazie\npamięć nieulotna\ntrwałość liczydła elektronicznego","reference":"PN-EN 16314:2013-11E 7.4; 7.13.4.8 7.13.4.9 7.18.3; C.5 C.9","norm_bases":["PN-EN 16314:2013-11E 7.4; 7.13.4.8 7.13.4.9 7.18.3; C.5 C.9"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe, ultradźwiękowe Funkcjonalności dodatkowe\nZakres:\nwpływ metrologiczny\ntrwałość zaworu\nodporność zaworu na zanieczyszczenia w gazie\npamięć nieulotna\ntrwałość liczydła elektronicznego PN-EN 16314:2013-11E 7.4; 7.13.4.8 7.13.4.9 7.18.3; C.5 C.9 Gazomierze miechowe, turbinowe, rotorowe, ultradzwiekowe Funkcjonalnosci dodatkowe\nZakres:\nwplyw metrologiczny\ntrwalosc zaworu\nodpornosc zaworu na zanieczyszczenia w gazie\npamiec nieulotna\ntrwalosc liczydla elektronicznego PN-EN 16314:2013-11E 7.4; 7.13.4.8 7.13.4.9 7.18.3; C.5 C.9","categories":["metrology","electronics"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Additional functionalities","parameters_en":[{"name":"metrological influence"},{"name":"valve durability"},{"name":"resistance of the valve to contaminants in the gas"},{"name":"non-volatile memory"},{"name":"durability of the electronic counter"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm, turbine, rotary and ultrasonic gas meters Additional functionalities Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. metrological influence valve durability resistance of the valve to contaminants in the gas non-volatile memory durability of the electronic counter PN-EN 16314:2013-11E 7.4; 7.13.4.8 7.13.4.9 7.18.3; C.5 C.9","test_object_en":"Diaphragm, turbine, rotary and ultrasonic gas meters","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式、涡轮式、腰轮式与超声波燃气表 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 16314:2013-11E 7.4; 7.13.4.8 7.13.4.9 7.18.3; C.5 C.9","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式、涡轮式、腰轮式与超声波燃气表"},{"_id":"6a7d75f9441eff5f156487f3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe","methodology":"Trwałość (metoda z cyklicznymi zmianami strumienia), Zakres strumienia objętości: (0,015 – 10) m3/h, Zakres temperatur: (-25 – +55) °C","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość (metoda z cyklicznymi zmianami strumienia), Zakres strumienia objętości: (0,015 – 10) m3/h, Zakres temperatur: (-25 – +55) °C","reference":"PB GM-08C wydanie 1 z dnia 20.03.2017","norm_bases":["PB GM-08C wydanie 1 z dnia 20.03.2017"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe Trwałość (metoda z cyklicznymi zmianami strumienia), Zakres strumienia objętości: (0,015 – 10) m3/h, Zakres temperatur: (-25 – +55) °C PB GM-08C wydanie 1 z dnia 20.03.2017 Gazomierze miechowe Trwalosc (metoda z cyklicznymi zmianami strumienia), Zakres strumienia objetosci: (0,015 – 10) m3/h, Zakres temperatur: (-25 – +55) °C PB GM-08C wydanie 1 z dnia 20.03.2017","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Durability (method with cyclic flow variations), Volume flow rate range: (0,015 – 10) m3/h, Temperature range: (-25 – +55) °C","search_en":"Diaphragm gas meters Durability (method with cyclic flow variations), Volume flow rate range: (0,015 – 10) m3/h, Temperature range: (-25 – +55) °C Flow Metrology Laboratory (GM-1) PB GM-08C wydanie 1 z dnia 20.03.2017","test_object_en":"Diaphragm gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"流量计量实验室（GM-1） PB GM-08C wydanie 1 z dnia 20.03.2017"},{"_id":"6a7d75f9441eff5f156487f4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze turbinowe, rotorowe","methodology":"Właściwości metrologiczne","parameters":[{"name":"odporność na pozycję montażu gazomierza"},{"name":"sprawdzenie wałków wyjściowych Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości metrologiczne\nZakres:\nodporność na pozycję montażu gazomierza\nsprawdzenie wałków wyjściowych Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm","reference":"OIML R 137-1&2:2012 p. 12.6.4 12.6.10","norm_bases":["OIML R 137-1&2:2012 p. 12.6.4 12.6.10"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze turbinowe, rotorowe Właściwości metrologiczne\nZakres:\nodporność na pozycję montażu gazomierza\nsprawdzenie wałków wyjściowych Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.4 12.6.10 Gazomierze turbinowe, rotorowe Wlasciwosci metrologiczne\nZakres:\nodpornosc na pozycje montazu gazomierza\nsprawdzenie walkow wyjsciowych Zakres strumienia objetosci: (0,015 – 1 000) m3/h\nMaksymalna srednica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.4 12.6.10","categories":["metrology"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Metrological properties","parameters_en":[{"name":"resistance to the mounting position of the gas meter"},{"name":"checking of the output shafts Volume flow rate range:","range":"(0,015 – 1 000) m3/h"},{"name":"Maximum nominal diameter: DNmax = 200 mm"}],"search_en":"Turbine and rotary gas meters Metrological properties Flow Metrology Laboratory (GM-1) resistance to the mounting position of the gas meter checking of the output shafts Volume flow rate range: Maximum nominal diameter: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.4 12.6.10","test_object_en":"Turbine and rotary gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"计量性能 流量计量实验室（GM-1） 最大公称直径：DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.4 12.6.10","parameters_zh":[{"name":"odporność na pozycję montażu gazomierza"},{"name":"sprawdzenie wałków wyjściowych Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"最大公称直径：DNmax = 200 mm"}],"methodology_zh":"计量性能"},{"_id":"6a7d75f9441eff5f156487f5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze turbinowe, rotorowe, ultradźwiękowe","methodology":"","parameters":[{"name":"odporność na kierunek przepływu Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nodporność na kierunek przepływu Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm","reference":"OIML R 137-1&2:2012 p. 12.6.5","norm_bases":["OIML R 137-1&2:2012 p. 12.6.5"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze turbinowe, rotorowe, ultradźwiękowe Zakres:\nodporność na kierunek przepływu Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.5 Gazomierze turbinowe, rotorowe, ultradzwiekowe Zakres:\nodpornosc na kierunek przeplywu Zakres strumienia objetosci: (0,015 – 1 000) m3/h\nMaksymalna srednica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.5","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","parameters_en":[{"name":"resistance to flow direction Volume flow range:","range":"(0,015 – 1 000) m3/h"},{"name":"Maximum nominal diameter: DNmax = 200 mm"}],"search_en":"Turbine, rotary and ultrasonic gas meters Flow Metrology Laboratory (GM-1) resistance to flow direction Volume flow range: Maximum nominal diameter: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.5","test_object_en":"Turbine, rotary and ultrasonic gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"流量计量实验室（GM-1） 最大公称直径：DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.5","parameters_zh":[{"name":"odporność na kierunek przepływu Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"最大公称直径：DNmax = 200 mm"}]},{"_id":"6a7d75f9441eff5f156487f6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze turbinowe, ultradźwiękowe, termiczne masowe","methodology":"Właściwości metrologiczne","parameters":[{"name":"odporność na zaburzenia przepływu Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości metrologiczne\nZakres:\nodporność na zaburzenia przepływu Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm","reference":"OIML R 137-1&2:2012 p. 12.6.8","norm_bases":["OIML R 137-1&2:2012 p. 12.6.8"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze turbinowe, ultradźwiękowe, termiczne masowe Właściwości metrologiczne\nZakres:\nodporność na zaburzenia przepływu Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.8 Gazomierze turbinowe, ultradzwiekowe, termiczne masowe Wlasciwosci metrologiczne\nZakres:\nodpornosc na zaburzenia przeplywu Zakres strumienia objetosci: (0,015 – 1 000) m3/h\nMaksymalna srednica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.8","categories":["metrology"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Metrological properties","parameters_en":[{"name":"resistance to flow disturbances Volume flow range:","range":"(0,015 – 1 000) m3/h"},{"name":"Maximum nominal diameter: DNmax = 200 mm"}],"search_en":"Turbine, ultrasonic and thermal mass gas meters Metrological properties Flow Metrology Laboratory (GM-1) resistance to flow disturbances Volume flow range: Maximum nominal diameter: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.8","test_object_en":"Turbine, ultrasonic and thermal mass gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"计量性能 流量计量实验室（GM-1） 最大公称直径：DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.8","parameters_zh":[{"name":"odporność na zaburzenia przepływu Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"最大公称直径：DNmax = 200 mm"}],"methodology_zh":"计量性能"},{"_id":"6a7d75f9441eff5f156487f7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe","methodology":"Właściwości metrologiczne","parameters":[{"name":"odporność na przeciążenia chwilowe Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości metrologiczne\nZakres:\nodporność na przeciążenia chwilowe Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm","reference":"OIML R 137-1&2:2012 p. 12.6.11","norm_bases":["OIML R 137-1&2:2012 p. 12.6.11"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe Właściwości metrologiczne\nZakres:\nodporność na przeciążenia chwilowe Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.11 Gazomierze miechowe, turbinowe, rotorowe Wlasciwosci metrologiczne\nZakres:\nodpornosc na przeciazenia chwilowe Zakres strumienia objetosci: (0,015 – 1 000) m3/h\nMaksymalna srednica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.11","categories":["metrology"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Metrological properties","parameters_en":[{"name":"resistance to momentary overloads Volume flow range:","range":"(0,015 – 1 000) m3/h"},{"name":"Maximum nominal diameter: DNmax = 200 mm"}],"search_en":"Diaphragm, turbine and rotary gas meters Metrological properties Flow Metrology Laboratory (GM-1) resistance to momentary overloads Volume flow range: Maximum nominal diameter: DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.11","test_object_en":"Diaphragm, turbine and rotary gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"计量性能 流量计量实验室（GM-1） 最大公称直径：DNmax = 200 mm OIML R 137-1&2:2012 p. 12.6.11","parameters_zh":[{"name":"odporność na przeciążenia chwilowe Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"最大公称直径：DNmax = 200 mm"}],"methodology_zh":"计量性能"},{"_id":"6a7d75f9441eff5f156487f8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe wyposażone w urządzenia elektroniczne (liczydła), Gazomierze ultradźwiękowe, termiczne masowe","methodology":"Badanie wpływu warunków środowiskowych:","parameters":[{"name":"badanie wpływu suchego gorąca (bez kondensacji)"},{"name":"badanie wpływu niskiej temperatury Maksymalna średnica nominalna: DNmax = 80 mm"},{"name":"Zakres temperatur","range":"(-40 – +70) °C"},{"name":"badanie wpływu wilgotnego gorąca, stan ustalony (brak kondensacji)"},{"name":"badanie wpływu kondensacji pary wodnej na obudowie podczas cyklicznych zmian temperatury Maksymalna średnica nominalna: DNmax = 80 mm"},{"name":"Zakres temperatur","range":"(-40 – +55) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Badanie wpływu warunków środowiskowych:\nZakres:\nbadanie wpływu suchego gorąca (bez kondensacji)\nbadanie wpływu niskiej temperatury Maksymalna średnica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +70) °C\nbadanie wpływu wilgotnego gorąca, stan ustalony (brak kondensacji)\nbadanie wpływu kondensacji pary wodnej na obudowie podczas cyklicznych zmian temperatury Maksymalna średnica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +55) °C","reference":"OIML R 137-1&2:2012 p. A.4.1.1; A.4.1.2; A.4.2.1; A.4.2.2","norm_bases":["OIML R 137-1&2:2012 p. A.4.1.1; A.4.1.2; A.4.2.1; A.4.2.2"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe wyposażone w urządzenia elektroniczne (liczydła), Gazomierze ultradźwiękowe, termiczne masowe Badanie wpływu warunków środowiskowych:\nZakres:\nbadanie wpływu suchego gorąca (bez kondensacji)\nbadanie wpływu niskiej temperatury Maksymalna średnica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +70) °C\nbadanie wpływu wilgotnego gorąca, stan ustalony (brak kondensacji)\nbadanie wpływu kondensacji pary wodnej na obudowie podczas cyklicznych zmian temperatury Maksymalna średnica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +55) °C OIML R 137-1&2:2012 p. A.4.1.1; A.4.1.2; A.4.2.1; A.4.2.2 Gazomierze miechowe, turbinowe, rotorowe wyposazone w urzadzenia elektroniczne (liczydla), Gazomierze ultradzwiekowe, termiczne masowe Badanie wplywu warunkow srodowiskowych:\nZakres:\nbadanie wplywu suchego goraca (bez kondensacji)\nbadanie wplywu niskiej temperatury Maksymalna srednica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +70) °C\nbadanie wplywu wilgotnego goraca, stan ustalony (brak kondensacji)\nbadanie wplywu kondensacji pary wodnej na obudowie podczas cyklicznych zmian temperatury Maksymalna srednica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +55) °C OIML R 137-1&2:2012 p. A.4.1.1; A.4.1.2; A.4.2.1; A.4.2.2","categories":["environment","electronics"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Testing of the influence of environmental conditions:","parameters_en":[{"name":"testing of the effect of dry heat (without condensation)"},{"name":"testing of the effect of low temperature Maximum nominal diameter: DNmax = 80 mm"},{"name":"Temperature range","range":"(-40 – +70) °C"},{"name":"testing of the effect of damp heat, steady state (no condensation)"},{"name":"testing of the effect of water vapour condensation on the enclosure during cyclic temperature changes Maximum nominal diameter: DNmax = 80 mm"},{"name":"Temperature range","range":"(-40 – +55) °C"}],"search_en":"Diaphragm, turbine and rotary gas meters equipped with electronic devices (index units), Ultrasonic and thermal mass gas meters Testing of the influence of environmental conditions: Flow Metrology Laboratory (GM-1) testing of the effect of dry heat (without condensation) testing of the effect of low temperature Maximum nominal diameter: DNmax = 80 mm Temperature range testing of the effect of damp heat, steady state (no condensation) testing of the effect of water vapour condensation on the enclosure during cyclic temperature changes Maximum nominal diameter: DNmax = 80 mm Temperature range OIML R 137-1&2:2012 p. A.4.1.1; A.4.1.2; A.4.2.1; A.4.2.2","test_object_en":"Diaphragm, turbine and rotary gas meters equipped with electronic devices (index units), Ultrasonic and thermal mass gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"配有电子装置（计数器）的膜式、涡轮式、腰轮式燃气表；超声波与热式质量燃气表 流量计量实验室（GM-1） 温度范围 温度范围 OIML R 137-1&2:2012 p. A.4.1.1; A.4.1.2; A.4.2.1; A.4.2.2","parameters_zh":[{"name":"badanie wpływu suchego gorąca (bez kondensacji)"},{"name":"badanie wpływu niskiej temperatury Maksymalna średnica nominalna: DNmax = 80 mm"},{"name":"温度范围","range":"(-40 – +70) °C"},{"name":"badanie wpływu wilgotnego gorąca, stan ustalony (brak kondensacji)"},{"name":"badanie wpływu kondensacji pary wodnej na obudowie podczas cyklicznych zmian temperatury Maksymalna średnica nominalna: DNmax = 80 mm"},{"name":"温度范围","range":"(-40 – +55) °C"}],"test_object_zh":"配有电子装置（计数器）的膜式、涡轮式、腰轮式燃气表；超声波与热式质量燃气表"},{"_id":"6a7d75f9441eff5f156487f9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, turbinowe, rotorowe wyposażone w urządzenia elektroniczne (liczydła), Gazomierze ultradźwiękowe, termiczne masowe","methodology":"Badanie wpływu czynników elektromagnetycznych:","parameters":[{"name":"badanie odporności na wyładowania elektrostatyczne"},{"name":"badanie odporności na serie szybkich elektrycznych stanów przejściowych Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Badanie wpływu czynników elektromagnetycznych:\nZakres:\nbadanie odporności na wyładowania elektrostatyczne\nbadanie odporności na serie szybkich elektrycznych stanów przejściowych Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm","reference":"OIML R 137-1&2:2012 p. A.6.2; A.6.3","norm_bases":["OIML R 137-1&2:2012 p. A.6.2; A.6.3"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze miechowe, turbinowe, rotorowe wyposażone w urządzenia elektroniczne (liczydła), Gazomierze ultradźwiękowe, termiczne masowe Badanie wpływu czynników elektromagnetycznych:\nZakres:\nbadanie odporności na wyładowania elektrostatyczne\nbadanie odporności na serie szybkich elektrycznych stanów przejściowych Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. A.6.2; A.6.3 Gazomierze miechowe, turbinowe, rotorowe wyposazone w urzadzenia elektroniczne (liczydla), Gazomierze ultradzwiekowe, termiczne masowe Badanie wplywu czynnikow elektromagnetycznych:\nZakres:\nbadanie odpornosci na wyladowania elektrostatyczne\nbadanie odpornosci na serie szybkich elektrycznych stanow przejsciowych Zakres strumienia objetosci: (0,015 – 1 000) m3/h\nMaksymalna srednica nominalna: DNmax = 200 mm OIML R 137-1&2:2012 p. A.6.2; A.6.3","categories":["electronics"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Testing of the influence of electromagnetic factors:","parameters_en":[{"name":"testing of immunity to electrostatic discharge"},{"name":"testing of immunity to electrical fast transient/burst Volume flow rate range:","range":"(0,015 – 1 000) m3/h"},{"name":"Maximum nominal diameter: DNmax = 200 mm"}],"search_en":"Diaphragm, turbine and rotary gas meters equipped with electronic devices (index units), Ultrasonic and thermal mass gas meters Testing of the influence of electromagnetic factors: Flow Metrology Laboratory (GM-1) testing of immunity to electrostatic discharge testing of immunity to electrical fast transient/burst Volume flow rate range: Maximum nominal diameter: DNmax = 200 mm OIML R 137-1&2:2012 p. A.6.2; A.6.3","test_object_en":"Diaphragm, turbine and rotary gas meters equipped with electronic devices (index units), Ultrasonic and thermal mass gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"配有电子装置（计数器）的膜式、涡轮式、腰轮式燃气表；超声波与热式质量燃气表 流量计量实验室（GM-1） 最大公称直径：DNmax = 200 mm OIML R 137-1&2:2012 p. A.6.2; A.6.3","parameters_zh":[{"name":"badanie odporności na wyładowania elektrostatyczne"},{"name":"badanie odporności na serie szybkich elektrycznych stanów przejściowych Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"最大公称直径：DNmax = 200 mm"}],"test_object_zh":"配有电子装置（计数器）的膜式、涡轮式、腰轮式燃气表；超声波与热式质量燃气表"},{"_id":"6a7d75f9441eff5f156487fa","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, ultradźwiękowe","methodology":"Zawór gazowy i system:","parameters":[{"name":"działanie zaworu"},{"name":"wydajność zaworu"},{"name":"wyświetlenie informacji o zaworze"},{"name":"strata ciśnienia"},{"name":"Zakres","range":"do 500 Pa"},{"name":"Zakres temperatur:","range":"(-40 – +70) °C"}],"technique":"Metoda pomiaru: bezpośrednia - zamykanie zaworu - otwieranie zaworu - odporność na temperatury składowania - odporność zaworu na mieszaninę toluenu/izooktanu - odporność zaworu na parę wodną - odporność na starzenie","techniques":["Metoda pomiaru: bezpośrednia - zamykanie zaworu - otwieranie zaworu - odporność na temperatury składowania - odporność zaworu na mieszaninę toluenu/izooktanu - odporność zaworu na parę wodną - odporność na starzenie"],"computed":[],"activity":"Zawór gazowy i system:\nZakres:\ndziałanie zaworu\nwydajność zaworu\nwyświetlenie informacji o zaworze\nstrata ciśnienia\nZakres do 500 Pa\nZakres temperatur: (-40 – +70) °C\nMetoda pomiaru: bezpośrednia - zamykanie zaworu - otwieranie zaworu - odporność na temperatury składowania - odporność zaworu na mieszaninę toluenu/izooktanu - odporność zaworu na parę wodną - odporność na starzenie","reference":"PN-EN 16314:2013-11E 7.13.3; 7.13.4.1.2; 7.13.4.2; 7.13.4.4; 7.13.4.5; 7.13.4.6; 7.13.4.7; D.3 D.4 D.5","norm_bases":["PN-EN 16314:2013-11E 7.13.3; 7.13.4.1.2; 7.13.4.2; 7.13.4.4; 7.13.4.5; 7.13.4.6; 7.13.4.7; D.3 D.4 D.5"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, ultradźwiękowe Zawór gazowy i system:\nZakres:\ndziałanie zaworu\nwydajność zaworu\nwyświetlenie informacji o zaworze\nstrata ciśnienia\nZakres do 500 Pa\nZakres temperatur: (-40 – +70) °C\nMetoda pomiaru: bezpośrednia - zamykanie zaworu - otwieranie zaworu - odporność na temperatury składowania - odporność zaworu na mieszaninę toluenu/izooktanu - odporność zaworu na parę wodną - odporność na starzenie PN-EN 16314:2013-11E 7.13.3; 7.13.4.1.2; 7.13.4.2; 7.13.4.4; 7.13.4.5; 7.13.4.6; 7.13.4.7; D.3 D.4 D.5 Gazomierze miechowe, ultradzwiekowe Zawor gazowy i system:\nZakres:\ndzialanie zaworu\nwydajnosc zaworu\nwyswietlenie informacji o zaworze\nstrata cisnienia\nZakres do 500 Pa\nZakres temperatur: (-40 – +70) °C\nMetoda pomiaru: bezposrednia - zamykanie zaworu - otwieranie zaworu - odpornosc na temperatury skladowania - odpornosc zaworu na mieszanine toluenu/izooktanu - odpornosc zaworu na pare wodna - odpornosc na starzenie PN-EN 16314:2013-11E 7.13.3; 7.13.4.1.2; 7.13.4.2; 7.13.4.4; 7.13.4.5; 7.13.4.6; 7.13.4.7; D.3 D.4 D.5","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Gas valve and system:","parameters_en":[{"name":"valve operation"},{"name":"valve capacity"},{"name":"display of valve information"},{"name":"pressure loss"},{"name":"Range","range":"do 500 Pa"},{"name":"Temperature range:","range":"(-40 – +70) °C"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm and ultrasonic gas meters Gas valve and system: Measurement method: direct - valve closing - valve opening - resistance to storage temperatures - valve resistance to a toluene/isooctane mixture - valve resistance to water vapour - resistance to ageing Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. valve operation valve capacity display of valve information pressure loss Range Temperature range: PN-EN 16314:2013-11E 7.13.3; 7.13.4.1.2; 7.13.4.2; 7.13.4.4; 7.13.4.5; 7.13.4.6; 7.13.4.7; D.3 D.4 D.5","technique_en":"Measurement method: direct - valve closing - valve opening - resistance to storage temperatures - valve resistance to a toluene/isooctane mixture - valve resistance to water vapour - resistance to ageing","test_object_en":"Diaphragm and ultrasonic gas meters","parameters_zh":[{"name":"działanie zaworu"},{"name":"wydajność zaworu"},{"name":"wyświetlenie informacji o zaworze"},{"name":"压力损失"},{"name":"范围","range":"do 500 Pa"},{"name":"温度范围：","range":"(-40 – +70) °C"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 压力损失 范围 温度范围： PN-EN 16314:2013-11E 7.13.3; 7.13.4.1.2; 7.13.4.2; 7.13.4.4; 7.13.4.5; 7.13.4.6; 7.13.4.7; D.3 D.4 D.5","lab_section_zh":"流量计量实验室（GM-1）"},{"_id":"6a7d75f9441eff5f156487fb","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki metaliczne, organiczne, anodowe tlenkowe","methodology":"Odporność na mgłę solną","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na mgłę solną","reference":"PN-ISO 7253:2000 | PN-ISO 7253:2000/Ap1:2001","norm_bases":["PN-ISO 7253:2000","PN-ISO 7253:2000/Ap1:2001"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powłoki metaliczne, organiczne, anodowe tlenkowe Odporność na mgłę solną PN-ISO 7253:2000 | PN-ISO 7253:2000/Ap1:2001 Powloki metaliczne, organiczne, anodowe tlenkowe Odpornosc na mgle solna PN-ISO 7253:2000 | PN-ISO 7253:2000/Ap1:2001","categories":["materials"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to salt fog","search_en":"Metallic, organic and anodic oxide coatings Resistance to salt fog Flow Metrology Laboratory (GM-1) PN-ISO 7253:2000 | PN-ISO 7253:2000/Ap1:2001","test_object_en":"Metallic, organic and anodic oxide coatings","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"流量计量实验室（GM-1） PN-ISO 7253:2000 | PN-ISO 7253:2000/Ap1:2001"},{"_id":"6a7d75f9441eff5f156487fc","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze ultradźwiękowe","methodology":"Właściwości metrologiczne:","parameters":[{"name":"dopuszczalne błędy graniczne"},{"name":"zależność błędów wskazań dla gazu i powietrza"},{"name":"strata ciśnienia"},{"name":"stabilność metrologiczna"},{"name":"odporność na zanieczyszczenia w strumieniu gazu"},{"name":"wpływ instalowania"},{"name":"przepływ zerowy"},{"name":"przepływ wsteczny"},{"name":"mały przepływ"},{"name":"duży przepływ"},{"name":"przepływ pulsacyjny"},{"name":"wrażliwość na temperaturę"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości metrologiczne:\nZakres:\ndopuszczalne błędy graniczne\nzależność błędów wskazań dla gazu i powietrza\nstrata ciśnienia\nstabilność metrologiczna\nodporność na zanieczyszczenia w strumieniu gazu\nwpływ instalowania\nprzepływ zerowy\nprzepływ wsteczny\nmały przepływ\nduży przepływ\nprzepływ pulsacyjny\nwrażliwość na temperaturę","reference":"PN-EN 14236:2019-01 5.3.2, 5.4, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11, 5.12, 5.13, 5.14","norm_bases":["PN-EN 14236:2019-01 5.3.2, 5.4, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11, 5.12, 5.13, 5.14"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze ultradźwiękowe Właściwości metrologiczne:\nZakres:\ndopuszczalne błędy graniczne\nzależność błędów wskazań dla gazu i powietrza\nstrata ciśnienia\nstabilność metrologiczna\nodporność na zanieczyszczenia w strumieniu gazu\nwpływ instalowania\nprzepływ zerowy\nprzepływ wsteczny\nmały przepływ\nduży przepływ\nprzepływ pulsacyjny\nwrażliwość na temperaturę PN-EN 14236:2019-01 5.3.2, 5.4, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11, 5.12, 5.13, 5.14 Gazomierze ultradzwiekowe Wlasciwosci metrologiczne:\nZakres:\ndopuszczalne bledy graniczne\nzaleznosc bledow wskazan dla gazu i powietrza\nstrata cisnienia\nstabilnosc metrologiczna\nodpornosc na zanieczyszczenia w strumieniu gazu\nwplyw instalowania\nprzeplyw zerowy\nprzeplyw wsteczny\nmaly przeplyw\nduzy przeplyw\nprzeplyw pulsacyjny\nwrazliwosc na temperature PN-EN 14236:2019-01 5.3.2, 5.4, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11, 5.12, 5.13, 5.14","categories":["metrology"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Metrological properties:","parameters_en":[{"name":"maximum permissible errors"},{"name":"relationship of indication errors for gas and air"},{"name":"pressure loss"},{"name":"metrological stability"},{"name":"resistance to contaminants in the gas stream"},{"name":"influence of installation"},{"name":"zero flow"},{"name":"reverse flow"},{"name":"low flow"},{"name":"high flow"},{"name":"pulsating flow"},{"name":"temperature sensitivity"}],"search_en":"Ultrasonic gas meters Metrological properties: Flow Metrology Laboratory (GM-1) maximum permissible errors relationship of indication errors for gas and air pressure loss metrological stability resistance to contaminants in the gas stream influence of installation zero flow reverse flow low flow high flow pulsating flow temperature sensitivity PN-EN 14236:2019-01 5.3.2, 5.4, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11, 5.12, 5.13, 5.14","test_object_en":"Ultrasonic gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"超声波燃气表 计量性能： 流量计量实验室（GM-1） 压力损失 PN-EN 14236:2019-01 5.3.2, 5.4, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11, 5.12, 5.13, 5.14","test_object_zh":"超声波燃气表","methodology_zh":"计量性能：","parameters_zh":[{"name":"dopuszczalne błędy graniczne"},{"name":"zależność błędów wskazań dla gazu i powietrza"},{"name":"压力损失"},{"name":"stabilność metrologiczna"},{"name":"odporność na zanieczyszczenia w strumieniu gazu"},{"name":"wpływ instalowania"},{"name":"przepływ zerowy"},{"name":"przepływ wsteczny"},{"name":"mały przepływ"},{"name":"duży przepływ"},{"name":"przepływ pulsacyjny"},{"name":"wrażliwość na temperaturę"}]},{"_id":"6a7d75f9441eff5f156487fd","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze ultradźwiękowe","methodology":"Budowa i materiały:","parameters":[{"name":"wytrzymałość na ciśnienia wewnętrzne"},{"name":"szczelność zewnętrzna"},{"name":"odporność cieplna"},{"name":"ustawienie przyłączy"},{"name":"średnice przyłącza"},{"name":"odporność na moment skręcający"},{"name":"odporność na moment zginający"},{"name":"wpływ wibracji"},{"name":"odporność na uderzenia"},{"name":"odporność na niewłaściwe postępowanie"},{"name":"odporność powłoki na zarysowanie"},{"name":"przyleganie powłoki ochronnej"},{"name":"odporność powłoki ochronnej na uderzenie"},{"name":"odporność chemiczna powłoki ochronnej"},{"name":"odporność na mgłę solną"},{"name":"odporność na wilgoć powłoki"},{"name":"odporność na wilgotność zewnętrzną"},{"name":"odporność na temperaturę przechowywania"},{"name":"odporność na pary toluenu i izooktanu"},{"name":"odporność na parę wodną"},{"name":"starzenie"}],"technique":null,"techniques":[],"computed":[],"activity":"Budowa i materiały:\nZakres:\nwytrzymałość na ciśnienia wewnętrzne\nszczelność zewnętrzna\nodporność cieplna\nustawienie przyłączy\nśrednice przyłącza\nodporność na moment skręcający\nodporność na moment zginający\nwpływ wibracji\nodporność na uderzenia\nodporność na niewłaściwe postępowanie\nodporność powłoki na zarysowanie\nprzyleganie powłoki ochronnej\nodporność powłoki ochronnej na uderzenie\nodporność chemiczna powłoki ochronnej\nodporność na mgłę solną\nodporność na wilgoć powłoki\nodporność na wilgotność zewnętrzną\nodporność na temperaturę przechowywania\nodporność na pary toluenu i izooktanu\nodporność na parę wodną\nstarzenie","reference":"PN-EN 14236:2019-01 6.2.3 6.2.4 6.2.5 6.2.6.1 6.2.6.2 6.2.6.3 6.2.6.4 6.2.7 6.2.8 6.2.9 6.3.2.1, 6.4.1 6.3.2.2, 6.3.4.1 6.3.2.3, 6.3.4.2 6.3.2.4, 6.3.3.1, 6.3.4.3, 6.3.5.1 6.3.2.5, 6.3.3.2 6.3.2.6, 6.3.3.3, 6.3.4.4, 6.3.5.2, 6.4.2 6.8 6.10 6.11 6.12 6.13","norm_bases":["PN-EN 14236:2019-01 6.2.3 6.2.4 6.2.5 6.2.6.1 6.2.6.2 6.2.6.3 6.2.6.4 6.2.7 6.2.8 6.2.9 6.3.2.1, 6.4.1 6.3.2.2, 6.3.4.1 6.3.2.3, 6.3.4.2 6.3.2.4, 6.3.3.1, 6.3.4.3, 6.3.5.1 6.3.2.5, 6.3.3.2 6.3.2.6, 6.3.3.3, 6.3.4.4, 6.3.5.2, 6.4.2 6.8 6.10 6.11 6.12 6.13"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze ultradźwiękowe Budowa i materiały:\nZakres:\nwytrzymałość na ciśnienia wewnętrzne\nszczelność zewnętrzna\nodporność cieplna\nustawienie przyłączy\nśrednice przyłącza\nodporność na moment skręcający\nodporność na moment zginający\nwpływ wibracji\nodporność na uderzenia\nodporność na niewłaściwe postępowanie\nodporność powłoki na zarysowanie\nprzyleganie powłoki ochronnej\nodporność powłoki ochronnej na uderzenie\nodporność chemiczna powłoki ochronnej\nodporność na mgłę solną\nodporność na wilgoć powłoki\nodporność na wilgotność zewnętrzną\nodporność na temperaturę przechowywania\nodporność na pary toluenu i izooktanu\nodporność na parę wodną\nstarzenie PN-EN 14236:2019-01 6.2.3 6.2.4 6.2.5 6.2.6.1 6.2.6.2 6.2.6.3 6.2.6.4 6.2.7 6.2.8 6.2.9 6.3.2.1, 6.4.1 6.3.2.2, 6.3.4.1 6.3.2.3, 6.3.4.2 6.3.2.4, 6.3.3.1, 6.3.4.3, 6.3.5.1 6.3.2.5, 6.3.3.2 6.3.2.6, 6.3.3.3, 6.3.4.4, 6.3.5.2, 6.4.2 6.8 6.10 6.11 6.12 6.13 Gazomierze ultradzwiekowe Budowa i materialy:\nZakres:\nwytrzymalosc na cisnienia wewnetrzne\nszczelnosc zewnetrzna\nodpornosc cieplna\nustawienie przylaczy\nsrednice przylacza\nodpornosc na moment skrecajacy\nodpornosc na moment zginajacy\nwplyw wibracji\nodpornosc na uderzenia\nodpornosc na niewlasciwe postepowanie\nodpornosc powloki na zarysowanie\nprzyleganie powloki ochronnej\nodpornosc powloki ochronnej na uderzenie\nodpornosc chemiczna powloki ochronnej\nodpornosc na mgle solna\nodpornosc na wilgoc powloki\nodpornosc na wilgotnosc zewnetrzna\nodpornosc na temperature przechowywania\nodpornosc na pary toluenu i izooktanu\nodpornosc na pare wodna\nstarzenie PN-EN 14236:2019-01 6.2.3 6.2.4 6.2.5 6.2.6.1 6.2.6.2 6.2.6.3 6.2.6.4 6.2.7 6.2.8 6.2.9 6.3.2.1, 6.4.1 6.3.2.2, 6.3.4.1 6.3.2.3, 6.3.4.2 6.3.2.4, 6.3.3.1, 6.3.4.3, 6.3.5.1 6.3.2.5, 6.3.3.2 6.3.2.6, 6.3.3.3, 6.3.4.4, 6.3.5.2, 6.4.2 6.8 6.10 6.11 6.12 6.13","categories":["materials"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Construction and materials:","parameters_en":[{"name":"resistance to internal pressures"},{"name":"external tightness"},{"name":"heat resistance"},{"name":"arrangement of connections"},{"name":"connection diameters"},{"name":"resistance to torsional moment"},{"name":"resistance to bending moment"},{"name":"effect of vibration"},{"name":"impact resistance"},{"name":"resistance to improper handling"},{"name":"scratch resistance of the coating"},{"name":"adhesion of the protective coating"},{"name":"impact resistance of the protective coating"},{"name":"chemical resistance of the protective coating"},{"name":"resistance to salt spray"},{"name":"moisture resistance of the coating"},{"name":"resistance to external humidity"},{"name":"resistance to storage temperature"},{"name":"resistance to toluene and isooctane vapours"},{"name":"resistance to water vapour"},{"name":"ageing"}],"search_en":"Ultrasonic gas meters Construction and materials: Flow Metrology Laboratory (GM-1) resistance to internal pressures external tightness heat resistance arrangement of connections connection diameters resistance to torsional moment resistance to bending moment effect of vibration impact resistance resistance to improper handling scratch resistance of the coating adhesion of the protective coating impact resistance of the protective coating chemical resistance of the protective coating resistance to salt spray moisture resistance of the coating resistance to external humidity resistance to storage temperature resistance to toluene and isooctane vapours resistance to water vapour ageing PN-EN 14236:2019-01 6.2.3 6.2.4 6.2.5 6.2.6.1 6.2.6.2 6.2.6.3 6.2.6.4 6.2.7 6.2.8 6.2.9 6.3.2.1, 6.4.1 6.3.2.2, 6.3.4.1 6.3.2.3, 6.3.4.2 6.3.2.4, 6.3.3.1, 6.3.4.3, 6.3.5.1 6.3.2.5, 6.3.3.2 6.3.2.6, 6.3.3.3, 6.3.4.4, 6.3.5.2, 6.4.2 6.8 6.10 6.11 6.12 6.13","test_object_en":"Ultrasonic gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"超声波燃气表 流量计量实验室（GM-1） 振动影响 防护涂层的附着力 PN-EN 14236:2019-01 6.2.3 6.2.4 6.2.5 6.2.6.1 6.2.6.2 6.2.6.3 6.2.6.4 6.2.7 6.2.8 6.2.9 6.3.2.1, 6.4.1 6.3.2.2, 6.3.4.1 6.3.2.3, 6.3.4.2 6.3.2.4, 6.3.3.1, 6.3.4.3, 6.3.5.1 6.3.2.5, 6.3.3.2 6.3.2.6, 6.3.3.3, 6.3.4.4, 6.3.5.2, 6.4.2 6.8 6.10 6.11 6.12 6.13","parameters_zh":[{"name":"wytrzymałość na ciśnienia wewnętrzne"},{"name":"szczelność zewnętrzna"},{"name":"odporność cieplna"},{"name":"ustawienie przyłączy"},{"name":"średnice przyłącza"},{"name":"odporność na moment skręcający"},{"name":"odporność na moment zginający"},{"name":"振动影响"},{"name":"odporność na uderzenia"},{"name":"odporność na niewłaściwe postępowanie"},{"name":"odporność powłoki na zarysowanie"},{"name":"防护涂层的附着力"},{"name":"odporność powłoki ochronnej na uderzenie"},{"name":"odporność chemiczna powłoki ochronnej"},{"name":"odporność na mgłę solną"},{"name":"odporność na wilgoć powłoki"},{"name":"odporność na wilgotność zewnętrzną"},{"name":"odporność na temperaturę przechowywania"},{"name":"odporność na pary toluenu i izooktanu"},{"name":"odporność na parę wodną"},{"name":"starzenie"}],"test_object_zh":"超声波燃气表"},{"_id":"6a7d75f9441eff5f156487fe","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze ultradźwiękowe","methodology":"Właściwości opcjonalne:","parameters":[{"name":"właściwości króćca manometrycznego"},{"name":"odporność na wysoką temperaturę otoczenia"},{"name":"sprawdzenie termicznego zaworu odcinającego"},{"name":"sprawdzenie gazomierza z korektorem temperatury"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości opcjonalne:\nZakres:\nwłaściwości króćca manometrycznego\nodporność na wysoką temperaturę otoczenia\nsprawdzenie termicznego zaworu odcinającego\nsprawdzenie gazomierza z korektorem temperatury","reference":"PN-EN 14236:2019-01 7.1, 7.2, 7.2.3, 7.3 (Załącznik C)","norm_bases":["PN-EN 14236:2019-01 7.1, 7.2, 7.2.3, 7.3 (Załącznik C)"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze ultradźwiękowe Właściwości opcjonalne:\nZakres:\nwłaściwości króćca manometrycznego\nodporność na wysoką temperaturę otoczenia\nsprawdzenie termicznego zaworu odcinającego\nsprawdzenie gazomierza z korektorem temperatury PN-EN 14236:2019-01 7.1, 7.2, 7.2.3, 7.3 (Załącznik C) Gazomierze ultradzwiekowe Wlasciwosci opcjonalne:\nZakres:\nwlasciwosci krocca manometrycznego\nodpornosc na wysoka temperature otoczenia\nsprawdzenie termicznego zaworu odcinajacego\nsprawdzenie gazomierza z korektorem temperatury PN-EN 14236:2019-01 7.1, 7.2, 7.2.3, 7.3 (Zalacznik C)","categories":["metrology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Optional properties:","parameters_en":[{"name":"properties of the pressure gauge connector"},{"name":"resistance to high ambient temperature"},{"name":"checking of the thermal shut-off valve"},{"name":"checking of the gas meter with temperature corrector"}],"search_en":"Ultrasonic gas meters Optional properties: Flow Metrology Laboratory (GM-1) properties of the pressure gauge connector resistance to high ambient temperature checking of the thermal shut-off valve checking of the gas meter with temperature corrector PN-EN 14236:2019-01 7.1, 7.2, 7.2.3, 7.3 (Załącznik C)","test_object_en":"Ultrasonic gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"超声波燃气表 流量计量实验室（GM-1） PN-EN 14236:2019-01 7.1, 7.2, 7.2.3, 7.3 (Załącznik C)","test_object_zh":"超声波燃气表"},{"_id":"6a7d75f9441eff5f156487ff","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze ultradźwiękowe","methodology":"Cechy konstrukcyjne liczydła:","parameters":[{"name":"sprawdzenie działania wyświetlacza"},{"name":"sprawdzenie działania wyświetlacza segmentowego"},{"name":"sprawdzenie działania pamięci nieulotnej"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy konstrukcyjne liczydła:\nZakres:\nsprawdzenie działania wyświetlacza\nsprawdzenie działania wyświetlacza segmentowego\nsprawdzenie działania pamięci nieulotnej","reference":"PN-EN 14236:2019-01 8.2, 8.3, 8.4","norm_bases":["PN-EN 14236:2019-01 8.2, 8.3, 8.4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze ultradźwiękowe Cechy konstrukcyjne liczydła:\nZakres:\nsprawdzenie działania wyświetlacza\nsprawdzenie działania wyświetlacza segmentowego\nsprawdzenie działania pamięci nieulotnej PN-EN 14236:2019-01 8.2, 8.3, 8.4 Gazomierze ultradzwiekowe Cechy konstrukcyjne liczydla:\nZakres:\nsprawdzenie dzialania wyswietlacza\nsprawdzenie dzialania wyswietlacza segmentowego\nsprawdzenie dzialania pamieci nieulotnej PN-EN 14236:2019-01 8.2, 8.3, 8.4","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Design features of the index:","parameters_en":[{"name":"checking the operation of the display"},{"name":"checking the operation of the segment display"},{"name":"checking the operation of non-volatile memory"}],"search_en":"Ultrasonic gas meters Design features of the index: Flow Metrology Laboratory (GM-1) checking the operation of the display checking the operation of the segment display checking the operation of non-volatile memory PN-EN 14236:2019-01 8.2, 8.3, 8.4","test_object_en":"Ultrasonic gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"超声波燃气表 流量计量实验室（GM-1） PN-EN 14236:2019-01 8.2, 8.3, 8.4","test_object_zh":"超声波燃气表"},{"_id":"6a7d75f9441eff5f15648800","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze ultradźwiękowe","methodology":"Badanie zasilania bateryjnego","parameters":[{"name":"wymiana baterii"},{"name":"przerwy napięcia"},{"name":"minimalne napięcie robocze"}],"technique":null,"techniques":[],"computed":[],"activity":"Badanie zasilania bateryjnego\nZakres:\nwymiana baterii\nprzerwy napięcia\nminimalne napięcie robocze","reference":"PN-EN 14236:2019-01 12.1, 12.2, 12.3","norm_bases":["PN-EN 14236:2019-01 12.1, 12.2, 12.3"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazomierze ultradźwiękowe Badanie zasilania bateryjnego\nZakres:\nwymiana baterii\nprzerwy napięcia\nminimalne napięcie robocze PN-EN 14236:2019-01 12.1, 12.2, 12.3 Gazomierze ultradzwiekowe Badanie zasilania bateryjnego\nZakres:\nwymiana baterii\nprzerwy napiecia\nminimalne napiecie robocze PN-EN 14236:2019-01 12.1, 12.2, 12.3","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Battery power supply test","parameters_en":[{"name":"battery replacement"},{"name":"voltage interruptions"},{"name":"minimum operating voltage"}],"search_en":"Ultrasonic gas meters Battery power supply test Flow Metrology Laboratory (GM-1) battery replacement voltage interruptions minimum operating voltage PN-EN 14236:2019-01 12.1, 12.2, 12.3","test_object_en":"Ultrasonic gas meters","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"超声波燃气表 流量计量实验室（GM-1） PN-EN 14236:2019-01 12.1, 12.2, 12.3","test_object_zh":"超声波燃气表"},{"_id":"6a7d75f9441eff5f15648801","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Błędy wskazań, strata ciśnienia, próg rozruchu, powtarzalność metrologiczna, objętość cykliczna, przeciążeniowy strumień objętości, wpływ innych urządzeń, przepływ wsteczny, Zakres strumienia objętości: (0,015 – 160) m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Błędy wskazań, strata ciśnienia, próg rozruchu, powtarzalność metrologiczna, objętość cykliczna, przeciążeniowy strumień objętości, wpływ innych urządzeń, przepływ wsteczny, Zakres strumienia objętości: (0,015 – 160) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Błędy wskazań, strata ciśnienia, próg rozruchu, powtarzalność metrologiczna, objętość cykliczna, przeciążeniowy strumień objętości, wpływ innych urządzeń, przepływ wsteczny, Zakres strumienia objętości: (0,015 – 160) m3/h PN-EN 1359 Gazomierze miechowe E Bledy wskazan, strata cisnienia, prog rozruchu, powtarzalnosc metrologiczna, objetosc cykliczna, przeciazeniowy strumien objetosci, wplyw innych urzadzen, przeplyw wsteczny, Zakres strumienia objetosci: (0,015 – 160) m3/h PN-EN 1359","categories":["metrology"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Errors of indication, pressure loss, starting flow rate, metrological repeatability, cyclic volume, overload flow rate, influence of other devices, reverse flow, Flow rate range: (0,015 – 160) m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Errors of indication, pressure loss, starting flow rate, metrological repeatability, cyclic volume, overload flow rate, influence of other devices, reverse flow, Flow rate range: (0,015 – 160) m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648802","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Wytrzymałość na ciśnienie wewnętrzne","parameters":[{"name":"Ciśnienie maksymalne","range":"200 kPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ciśnienie wewnętrzne\nCiśnienie maksymalne 200 kPa","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Wytrzymałość na ciśnienie wewnętrzne\nCiśnienie maksymalne 200 kPa PN-EN 1359 Gazomierze miechowe E Wytrzymalosc na cisnienie wewnetrzne\nCisnienie maksymalne 200 kPa PN-EN 1359","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to internal pressure","parameters_en":[{"name":"Maximum pressure","range":"200 kPa"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Resistance to internal pressure Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Maximum pressure PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 内压强度 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E","methodology_zh":"内压强度"},{"_id":"6a7d75f9441eff5f15648803","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Wytrzymałość króćców przyłączeniowych na moment skręcający","parameters":[{"name":"Ciśnienie maksymalne","range":"50 kPa"},{"name":"Zakres obciążeń","range":"(0 – 170) Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość króćców przyłączeniowych na moment skręcający\nZakres:\nCiśnienie maksymalne 50 kPa\nZakres obciążeń (0 – 170) Nm","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Wytrzymałość króćców przyłączeniowych na moment skręcający\nZakres:\nCiśnienie maksymalne 50 kPa\nZakres obciążeń (0 – 170) Nm PN-EN 1359 Gazomierze miechowe E Wytrzymalosc kroccow przylaczeniowych na moment skrecajacy\nZakres:\nCisnienie maksymalne 50 kPa\nZakres obciazen (0 – 170) Nm PN-EN 1359","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance of the connection spigots to torsional moment","parameters_en":[{"name":"Maximum pressure","range":"50 kPa"},{"name":"Load range","range":"(0 – 170) Nm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Resistance of the connection spigots to torsional moment Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Maximum pressure Load range PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 载荷范围 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"Ciśnienie maksymalne","range":"50 kPa"},{"name":"载荷范围","range":"(0 – 170) Nm"}],"test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648804","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Kierunek ustawienia króćców przyłączeniowych, wymiary gwintów i kołnierzy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kierunek ustawienia króćców przyłączeniowych, wymiary gwintów i kołnierzy","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Kierunek ustawienia króćców przyłączeniowych, wymiary gwintów i kołnierzy PN-EN 1359 Gazomierze miechowe E Kierunek ustawienia kroccow przylaczeniowych, wymiary gwintow i kolnierzy PN-EN 1359","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Orientation of the connection ports, dimensions of threads and flanges","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Orientation of the connection ports, dimensions of threads and flanges Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648805","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Wytrzymałość króćców przyłączeniowych na moment zginający Maksymalne ciśnienie robocze: 100 kPa","parameters":[{"name":"Zakres obciążeń","range":"(0 – 60) Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość króćców przyłączeniowych na moment zginający Maksymalne ciśnienie robocze: 100 kPa\nZakres obciążeń (0 – 60) Nm","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Wytrzymałość króćców przyłączeniowych na moment zginający Maksymalne ciśnienie robocze: 100 kPa\nZakres obciążeń (0 – 60) Nm PN-EN 1359 Gazomierze miechowe E Wytrzymalosc kroccow przylaczeniowych na moment zginajacy Maksymalne cisnienie robocze: 100 kPa\nZakres obciazen (0 – 60) Nm PN-EN 1359","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance of the connection spigots to bending moment Maximum working pressure: 100 kPa","parameters_en":[{"name":"Load range","range":"(0 – 60) Nm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Resistance of the connection spigots to bending moment Maximum working pressure: 100 kPa Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Load range PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 载荷范围 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"载荷范围","range":"(0 – 60) Nm"}],"test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648806","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Trwałość, Zakres strumienia objętości: (0,015 – 160) m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość, Zakres strumienia objętości: (0,015 – 160) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Trwałość, Zakres strumienia objętości: (0,015 – 160) m3/h PN-EN 1359 Gazomierze miechowe E Trwalosc, Zakres strumienia objetosci: (0,015 – 160) m3/h PN-EN 1359","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Durability, Volume flow rate range: (0,015 – 160) m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Durability, Volume flow rate range: (0,015 – 160) m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648807","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Odporność na niewłaściwe postępowanie, Maksymalne ciśnienie robocze: 100 kPa, Zakres strumienia objętości: (0,015 – 160) m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na niewłaściwe postępowanie, Maksymalne ciśnienie robocze: 100 kPa, Zakres strumienia objętości: (0,015 – 160) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Odporność na niewłaściwe postępowanie, Maksymalne ciśnienie robocze: 100 kPa, Zakres strumienia objętości: (0,015 – 160) m3/h PN-EN 1359 Gazomierze miechowe E Odpornosc na niewlasciwe postepowanie, Maksymalne cisnienie robocze: 100 kPa, Zakres strumienia objetosci: (0,015 – 160) m3/h PN-EN 1359","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to mishandling, Maximum working pressure: 100 kPa, Volume flow range: (0,015 – 160) m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Resistance to mishandling, Maximum working pressure: 100 kPa, Volume flow range: (0,015 – 160) m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648808","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Wpływ temperatury na błędy wskazań Maksymalne ciśnienie robocze: 100 kPa","parameters":[{"name":"Zakres temperatur","range":"(-40 – +70) °C"},{"name":"Zakres strumienia objętości:","range":"(0,015 – 100) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ temperatury na błędy wskazań Maksymalne ciśnienie robocze: 100 kPa\nZakres:\nZakres temperatur (-40 – +70) °C\nZakres strumienia objętości: (0,015 – 100) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Wpływ temperatury na błędy wskazań Maksymalne ciśnienie robocze: 100 kPa\nZakres:\nZakres temperatur (-40 – +70) °C\nZakres strumienia objętości: (0,015 – 100) m3/h PN-EN 1359 Gazomierze miechowe E Wplyw temperatury na bledy wskazan Maksymalne cisnienie robocze: 100 kPa\nZakres:\nZakres temperatur (-40 – +70) °C\nZakres strumienia objetosci: (0,015 – 100) m3/h PN-EN 1359","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of temperature on indication errors Maximum working pressure: 100 kPa","parameters_en":[{"name":"Temperature range","range":"(-40 – +70) °C"},{"name":"Volume flow rate range:","range":"(0,015 – 100) m3/h"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Effect of temperature on indication errors Maximum working pressure: 100 kPa Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Temperature range Volume flow rate range: PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 体积流量范围： PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E","parameters_zh":[{"name":"温度范围","range":"(-40 – +70) °C"},{"name":"体积流量范围：","range":"(0,015 – 100) m3/h"}]},{"_id":"6a7d75f9441eff5f15648809","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Starzenie","parameters":[{"name":"Temperatura maksymalna","range":"70 °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Starzenie\nTemperatura maksymalna 70 °C","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Starzenie\nTemperatura maksymalna 70 °C PN-EN 1359 Gazomierze miechowe E Starzenie\nTemperatura maksymalna 70 °C PN-EN 1359","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Ageing","parameters_en":[{"name":"Maximum temperature","range":"70 °C"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Ageing Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Maximum temperature PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 最高温度 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E","parameters_zh":[{"name":"最高温度","range":"70 °C"}]},{"_id":"6a7d75f9441eff5f1564880a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Wpływ wibracji","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ wibracji","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Wpływ wibracji PN-EN 1359 Gazomierze miechowe E Wplyw wibracji PN-EN 1359","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of vibration","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Effect of vibration Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f1564880b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Odporność membran i części wewnętrznych gazomierza na parę wodną, Maksymalna wilgotność względna: 85 %, Zakres strumienia objętości: (0,015 – 160) m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność membran i części wewnętrznych gazomierza na parę wodną, Maksymalna wilgotność względna: 85 %, Zakres strumienia objętości: (0,015 – 160) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Odporność membran i części wewnętrznych gazomierza na parę wodną, Maksymalna wilgotność względna: 85 %, Zakres strumienia objętości: (0,015 – 160) m3/h PN-EN 1359 Gazomierze miechowe E Odpornosc membran i czesci wewnetrznych gazomierza na pare wodna, Maksymalna wilgotnosc wzgledna: 85 %, Zakres strumienia objetosci: (0,015 – 160) m3/h PN-EN 1359","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance of the diaphragms and internal parts of the gas meter to water vapour, Maximum relative humidity: 85 %, Volume flow range: (0,015 – 160) m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Resistance of the diaphragms and internal parts of the gas meter to water vapour, Maximum relative humidity: 85 %, Volume flow range: (0,015 – 160) m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f1564880c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Odporność membran i części wewnętrznych gazomierza miechowego na pary toluenu/izooktanu, Zakres strumienia objętości: (0,015 – 100) m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność membran i części wewnętrznych gazomierza miechowego na pary toluenu/izooktanu, Zakres strumienia objętości: (0,015 – 100) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Odporność membran i części wewnętrznych gazomierza miechowego na pary toluenu/izooktanu, Zakres strumienia objętości: (0,015 – 100) m3/h PN-EN 1359 Gazomierze miechowe E Odpornosc membran i czesci wewnetrznych gazomierza miechowego na pary toluenu/izooktanu, Zakres strumienia objetosci: (0,015 – 100) m3/h PN-EN 1359","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance of the diaphragms and internal parts of the diaphragm gas meter to toluene/isooctane vapours, Volume flow range: (0,015 – 100) m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Resistance of the diaphragms and internal parts of the diaphragm gas meter to toluene/isooctane vapours, Volume flow range: (0,015 – 100) m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f1564880d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Odporność powłoki ochronnej na zarysowanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność powłoki ochronnej na zarysowanie","reference":"PN-EN 1359 | PN-EN ISO 1518-1","norm_bases":["PN-EN 1359","PN-EN ISO 1518-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Odporność powłoki ochronnej na zarysowanie PN-EN 1359 | PN-EN ISO 1518-1 Gazomierze miechowe E Odpornosc powloki ochronnej na zarysowanie PN-EN 1359 | PN-EN ISO 1518-1","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Scratch resistance of the protective coating","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Scratch resistance of the protective coating Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359 | PN-EN ISO 1518-1","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359 | PN-EN ISO 1518-1","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f1564880e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Odporność chemiczna powłoki ochronnej gazomierza na korozję zewnętrzną","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność chemiczna powłoki ochronnej gazomierza na korozję zewnętrzną","reference":"PN-EN 1359 | PN-EN ISO 2812-1","norm_bases":["PN-EN 1359","PN-EN ISO 2812-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Odporność chemiczna powłoki ochronnej gazomierza na korozję zewnętrzną PN-EN 1359 | PN-EN ISO 2812-1 Gazomierze miechowe E Odpornosc chemiczna powloki ochronnej gazomierza na korozje zewnetrzna PN-EN 1359 | PN-EN ISO 2812-1","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Chemical resistance of the gas meter protective coating to external corrosion","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Chemical resistance of the gas meter protective coating to external corrosion Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359 | PN-EN ISO 2812-1","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359 | PN-EN ISO 2812-1","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f1564880f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Odporność chemiczna powłoki ochronnej gazomierza na korozję wewnętrzną","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność chemiczna powłoki ochronnej gazomierza na korozję wewnętrzną","reference":"PN-EN 1359 | PN-EN ISO 2812-1","norm_bases":["PN-EN 1359","PN-EN ISO 2812-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Odporność chemiczna powłoki ochronnej gazomierza na korozję wewnętrzną PN-EN 1359 | PN-EN ISO 2812-1 Gazomierze miechowe E Odpornosc chemiczna powloki ochronnej gazomierza na korozje wewnetrzna PN-EN 1359 | PN-EN ISO 2812-1","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Chemical resistance of the gas meter protective coating to internal corrosion","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Chemical resistance of the gas meter protective coating to internal corrosion Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359 | PN-EN ISO 2812-1","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359 | PN-EN ISO 2812-1","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648810","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Cechy konstrukcyjne liczydła i odporność okienka i obudowy liczydła gazomierza na uderzenie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy konstrukcyjne liczydła i odporność okienka i obudowy liczydła gazomierza na uderzenie","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Cechy konstrukcyjne liczydła i odporność okienka i obudowy liczydła gazomierza na uderzenie PN-EN 1359 Gazomierze miechowe E Cechy konstrukcyjne liczydla i odpornosc okienka i obudowy liczydla gazomierza na uderzenie PN-EN 1359","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Design features of the index and impact resistance of the window and the housing of the gas meter index","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Design features of the index and impact resistance of the window and the housing of the gas meter index Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648811","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Odporność na obojętną mgłę solną","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na obojętną mgłę solną","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Odporność na obojętną mgłę solną PN-EN 1359 Gazomierze miechowe E Odpornosc na obojetna mgle solna PN-EN 1359","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to neutral salt spray","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Resistance to neutral salt spray Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 中性盐雾的耐受性 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E","methodology_zh":"中性盐雾的耐受性"},{"_id":"6a7d75f9441eff5f15648812","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Odporność na korozję zewnętrzną i wewnętrzną z zastosowaniem wilgotności, Kondensacja ciągła","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na korozję zewnętrzną i wewnętrzną z zastosowaniem wilgotności, Kondensacja ciągła","reference":"PN-EN 1359 | PN-EN ISO 6270-1","norm_bases":["PN-EN 1359","PN-EN ISO 6270-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Odporność na korozję zewnętrzną i wewnętrzną z zastosowaniem wilgotności, Kondensacja ciągła PN-EN 1359 | PN-EN ISO 6270-1 Gazomierze miechowe E Odpornosc na korozje zewnetrzna i wewnetrzna z zastosowaniem wilgotnosci, Kondensacja ciagla PN-EN 1359 | PN-EN ISO 6270-1","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to external and internal corrosion with the use of humidity, Continuous condensation","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Resistance to external and internal corrosion with the use of humidity, Continuous condensation Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359 | PN-EN ISO 6270-1","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359 | PN-EN ISO 6270-1","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648813","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Odporność na środowisko i wilgotność, Zakres strumienia objętości: (0,015 – 160) m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na środowisko i wilgotność, Zakres strumienia objętości: (0,015 – 160) m3/h","reference":"PN-EN 1359 | PN-EN ISO 6270-1","norm_bases":["PN-EN 1359","PN-EN ISO 6270-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Odporność na środowisko i wilgotność, Zakres strumienia objętości: (0,015 – 160) m3/h PN-EN 1359 | PN-EN ISO 6270-1 Gazomierze miechowe E Odpornosc na srodowisko i wilgotnosc, Zakres strumienia objetosci: (0,015 – 160) m3/h PN-EN 1359 | PN-EN ISO 6270-1","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to environment and humidity, Volume flow range: (0,015 – 160) m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Resistance to environment and humidity, Volume flow range: (0,015 – 160) m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359 | PN-EN ISO 6270-1","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359 | PN-EN ISO 6270-1","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648814","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Wpływ magnesów neodymowych na błędy wskazań, straty ciśnienia, Zakres strumienia objętości: (0,015 – 160) m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ magnesów neodymowych na błędy wskazań, straty ciśnienia, Zakres strumienia objętości: (0,015 – 160) m3/h","reference":"PB GM-01","norm_bases":["PB GM-01"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Wpływ magnesów neodymowych na błędy wskazań, straty ciśnienia, Zakres strumienia objętości: (0,015 – 160) m3/h PB GM-01 Gazomierze miechowe E Wplyw magnesow neodymowych na bledy wskazan, straty cisnienia, Zakres strumienia objetosci: (0,015 – 160) m3/h PB GM-01","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of neodymium magnets on indication errors, pressure loss, Volume flow rate range: (0,015 – 160) m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Effect of neodymium magnets on indication errors, pressure loss, Volume flow rate range: (0,015 – 160) m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PB GM-01","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PB GM-01","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648815","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe E","methodology":"Wymiary gwintów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary gwintów","reference":"PN-EN ISO 228-1","norm_bases":["PN-EN ISO 228-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe E Wymiary gwintów PN-EN ISO 228-1 Gazomierze miechowe E Wymiary gwintow PN-EN ISO 228-1","categories":["other"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Thread dimensions","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters E Thread dimensions Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 228-1","test_object_en":"Diaphragm gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 228-1","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648816","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe z wbudowanym korektorem temperatury E","methodology":"Błędy wskazań w stałej temperaturze","parameters":[{"name":"Zakres temperatur","range":"(-40 – +70) °C"},{"name":"Zakres strumienia objętości:","range":"(0,015 – 100) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Błędy wskazań w stałej temperaturze\nZakres:\nZakres temperatur (-40 – +70) °C\nZakres strumienia objętości: (0,015 – 100) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe z wbudowanym korektorem temperatury E Błędy wskazań w stałej temperaturze\nZakres:\nZakres temperatur (-40 – +70) °C\nZakres strumienia objętości: (0,015 – 100) m3/h PN-EN 1359 Gazomierze miechowe z wbudowanym korektorem temperatury E Bledy wskazan w stalej temperaturze\nZakres:\nZakres temperatur (-40 – +70) °C\nZakres strumienia objetosci: (0,015 – 100) m3/h PN-EN 1359","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Errors of indication at constant temperature","parameters_en":[{"name":"Temperature range","range":"(-40 – +70) °C"},{"name":"Volume flow rate range:","range":"(0,015 – 100) m3/h"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters with built-in temperature conversion device E Errors of indication at constant temperature Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Temperature range Volume flow rate range: PN-EN 1359","test_object_en":"Diaphragm gas meters with built-in temperature conversion device E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"带内置温度修正器的膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 体积流量范围： PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"温度范围","range":"(-40 – +70) °C"},{"name":"体积流量范围：","range":"(0,015 – 100) m3/h"}],"test_object_zh":"带内置温度修正器的膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648817","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe z wbudowanym korektorem temperatury E","methodology":"Trwałość, Zakres strumienia objętości: (0,015 – 160) m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość, Zakres strumienia objętości: (0,015 – 160) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe z wbudowanym korektorem temperatury E Trwałość, Zakres strumienia objętości: (0,015 – 160) m3/h PN-EN 1359 Gazomierze miechowe z wbudowanym korektorem temperatury E Trwalosc, Zakres strumienia objetosci: (0,015 – 160) m3/h PN-EN 1359","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Durability, Volume flow rate range: (0,015 – 160) m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters with built-in temperature conversion device E Durability, Volume flow rate range: (0,015 – 160) m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters with built-in temperature conversion device E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"带内置温度修正器的膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"带内置温度修正器的膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648818","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe z wbudowanym korektorem temperatury E","methodology":"Błędy wskazań w różnych temperaturach otoczenia i gazu","parameters":[{"name":"Zakres temperatur","range":"(-40 – +70) °C"},{"name":"Zakres strumienia objętości:","range":"(0,015 – 100) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Błędy wskazań w różnych temperaturach otoczenia i gazu\nZakres:\nZakres temperatur (-40 – +70) °C\nZakres strumienia objętości: (0,015 – 100) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe z wbudowanym korektorem temperatury E Błędy wskazań w różnych temperaturach otoczenia i gazu\nZakres:\nZakres temperatur (-40 – +70) °C\nZakres strumienia objętości: (0,015 – 100) m3/h PN-EN 1359 Gazomierze miechowe z wbudowanym korektorem temperatury E Bledy wskazan w roznych temperaturach otoczenia i gazu\nZakres:\nZakres temperatur (-40 – +70) °C\nZakres strumienia objetosci: (0,015 – 100) m3/h PN-EN 1359","categories":["other"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Errors of indication at various ambient and gas temperatures","parameters_en":[{"name":"Temperature range","range":"(-40 – +70) °C"},{"name":"Volume flow rate range:","range":"(0,015 – 100) m3/h"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters with built-in temperature conversion device E Errors of indication at various ambient and gas temperatures Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Temperature range Volume flow rate range: PN-EN 1359","test_object_en":"Diaphragm gas meters with built-in temperature conversion device E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"带内置温度修正器的膜式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 体积流量范围： PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"温度范围","range":"(-40 – +70) °C"},{"name":"体积流量范围：","range":"(0,015 – 100) m3/h"}],"test_object_zh":"带内置温度修正器的膜式燃气表 E"},{"_id":"6a7d75f9441eff5f15648819","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, uszczelki do gazomierzy miechowych, szafki gazownicze E","methodology":"Odporność gazomierzy na temperaturę składowania Odporność uszczelek i szafek na warunki środowiskowe Zakres strumienia objętości: (0,015 – 160) m3/h,","parameters":[{"name":"Zakres temperatur","range":"(-70 – +70) °C"},{"name":"Maksymalne wymiary obiektu:","range":"(650x650x700) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność gazomierzy na temperaturę składowania Odporność uszczelek i szafek na warunki środowiskowe Zakres strumienia objętości: (0,015 – 160) m3/h,\nZakres:\nZakres temperatur (-70 – +70) °C\nMaksymalne wymiary obiektu: (650x650x700) mm","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, uszczelki do gazomierzy miechowych, szafki gazownicze E Odporność gazomierzy na temperaturę składowania Odporność uszczelek i szafek na warunki środowiskowe Zakres strumienia objętości: (0,015 – 160) m3/h,\nZakres:\nZakres temperatur (-70 – +70) °C\nMaksymalne wymiary obiektu: (650x650x700) mm PN-EN 1359 Gazomierze miechowe, uszczelki do gazomierzy miechowych, szafki gazownicze E Odpornosc gazomierzy na temperature skladowania Odpornosc uszczelek i szafek na warunki srodowiskowe Zakres strumienia objetosci: (0,015 – 160) m3/h,\nZakres:\nZakres temperatur (-70 – +70) °C\nMaksymalne wymiary obiektu: (650x650x700) mm PN-EN 1359","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance of gas meters to storage temperature Resistance of seals and cabinets to environmental conditions Volume flow range: (0,015 – 160) m3/h,","parameters_en":[{"name":"Temperature range","range":"(-70 – +70) °C"},{"name":"Maximum dimensions of the object:","range":"(650x650x700) mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters, gaskets for diaphragm gas meters, gas meter cabinets E Resistance of gas meters to storage temperature Resistance of seals and cabinets to environmental conditions Volume flow range: (0,015 – 160) m3/h, Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Temperature range Maximum dimensions of the object: PN-EN 1359","test_object_en":"Diaphragm gas meters, gaskets for diaphragm gas meters, gas meter cabinets E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 对象最大尺寸： PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"温度范围","range":"(-70 – +70) °C"},{"name":"对象最大尺寸：","range":"(650x650x700) mm"}]},{"_id":"6a7d75f9441eff5f1564881a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, uszczelki do gazomierzy miechowych, łączniki do gazomierzy miechowych, inne elementy instalacji gazowej E","methodology":"Odporność na wysoką temperaturę otoczenia","parameters":[{"name":"Zakres strumienia objętości w warunkach normalnych: (0,014 – 0,9) m3/h"},{"name":"Temperatura maksymalna","range":"650 °C"},{"name":"Maksymalne wymiary obiektu:","range":"(520x450x650) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wysoką temperaturę otoczenia\nZakres:\nZakres strumienia objętości w warunkach normalnych: (0,014 – 0,9) m3/h\nTemperatura maksymalna 650 °C\nMaksymalne wymiary obiektu: (520x450x650) mm","reference":"PN-EN 1359 | PN-EN 1775","norm_bases":["PN-EN 1359","PN-EN 1775"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, uszczelki do gazomierzy miechowych, łączniki do gazomierzy miechowych, inne elementy instalacji gazowej E Odporność na wysoką temperaturę otoczenia\nZakres:\nZakres strumienia objętości w warunkach normalnych: (0,014 – 0,9) m3/h\nTemperatura maksymalna 650 °C\nMaksymalne wymiary obiektu: (520x450x650) mm PN-EN 1359 | PN-EN 1775 Gazomierze miechowe, uszczelki do gazomierzy miechowych, laczniki do gazomierzy miechowych, inne elementy instalacji gazowej E Odpornosc na wysoka temperature otoczenia\nZakres:\nZakres strumienia objetosci w warunkach normalnych: (0,014 – 0,9) m3/h\nTemperatura maksymalna 650 °C\nMaksymalne wymiary obiektu: (520x450x650) mm PN-EN 1359 | PN-EN 1775","categories":["other"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to high ambient temperature","parameters_en":[{"name":"Range of the volume flow rate under normal conditions: (0,014 – 0,9) m3/h"},{"name":"Maximum temperature","range":"650 °C"},{"name":"Maximum dimensions of the object:","range":"(520x450x650) mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters, gaskets for diaphragm gas meters, connectors for diaphragm gas meters, other gas installation components E Resistance to high ambient temperature Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range of the volume flow rate under normal conditions: (0,014 – 0,9) m3/h Maximum temperature Maximum dimensions of the object: PN-EN 1359 | PN-EN 1775","test_object_en":"Diaphragm gas meters, gaskets for diaphragm gas meters, connectors for diaphragm gas meters, other gas installation components E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 最高温度 对象最大尺寸： PN-EN 1359 | PN-EN 1775","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"Zakres strumienia objętości w warunkach normalnych: (0,014 – 0,9) m3/h"},{"name":"最高温度","range":"650 °C"},{"name":"对象最大尺寸：","range":"(520x450x650) mm"}]},{"_id":"6a7d75f9441eff5f1564881b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, części złączne do instalacji gazowych E","methodology":"Szczelność zewnętrzna, Maksymalne ciśnienie robocze: 100 kPa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność zewnętrzna, Maksymalne ciśnienie robocze: 100 kPa","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, części złączne do instalacji gazowych E Szczelność zewnętrzna, Maksymalne ciśnienie robocze: 100 kPa PN-EN 1359 Gazomierze miechowe, czesci zlaczne do instalacji gazowych E Szczelnosc zewnetrzna, Maksymalne cisnienie robocze: 100 kPa PN-EN 1359","categories":["other"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"External tightness, Maximum working pressure: 100 kPa","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters, connecting components for gas installations E External tightness, Maximum working pressure: 100 kPa Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters, connecting components for gas installations E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）"},{"_id":"6a7d75f9441eff5f1564881c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze miechowe, szafki gazownicze E","methodology":"Odporność na uderzenie, Maksymalne ciśnienie robocze: 100 kPa, Zakres strumienia objętości: (0,015 – 160) m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na uderzenie, Maksymalne ciśnienie robocze: 100 kPa, Zakres strumienia objętości: (0,015 – 160) m3/h","reference":"PN-EN 1359","norm_bases":["PN-EN 1359"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze miechowe, szafki gazownicze E Odporność na uderzenie, Maksymalne ciśnienie robocze: 100 kPa, Zakres strumienia objętości: (0,015 – 160) m3/h PN-EN 1359 Gazomierze miechowe, szafki gazownicze E Odpornosc na uderzenie, Maksymalne cisnienie robocze: 100 kPa, Zakres strumienia objetosci: (0,015 – 160) m3/h PN-EN 1359","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Impact resistance, Maximum working pressure: 100 kPa, Volume flow range: (0,015 – 160) m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Diaphragm gas meters, gas meter cabinets E Impact resistance, Maximum working pressure: 100 kPa, Volume flow range: (0,015 – 160) m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1359","test_object_en":"Diaphragm gas meters, gas meter cabinets E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1359","lab_section_zh":"流量计量实验室（GM-1）"},{"_id":"6a7d75f9441eff5f1564881d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze turbinowe E","methodology":"Średnica przyłączy i wymiary","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Średnica przyłączy i wymiary","reference":"PN-EN 12261 p.4","norm_bases":["PN-EN 12261 p.4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze turbinowe E Średnica przyłączy i wymiary PN-EN 12261 p.4 Gazomierze turbinowe E Srednica przylaczy i wymiary PN-EN 12261 p.4","categories":["other"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Diameter of connections and dimensions","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Turbine gas meters E Diameter of connections and dimensions Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12261 p.4","test_object_en":"Turbine gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"涡轮式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12261 p.4","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"涡轮式燃气表 E"},{"_id":"6a7d75f9441eff5f1564881e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze turbinowe E","methodology":"Właściwości metrologiczne:","parameters":[{"name":"błąd wskazania"},{"name":"powtarzalność metrologiczna"},{"name":"liniowość"},{"name":"odporność na pozycję montażu gazomierza"},{"name":"odporność na przeciążenie chwilowe"},{"name":"odporność na warunki instalacji"},{"name":"strata ciśnienia Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm"},{"name":"Zakres temperatur","range":"(-40 – +70) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości metrologiczne:\nZakres:\nbłąd wskazania\npowtarzalność metrologiczna\nliniowość\nodporność na pozycję montażu gazomierza\nodporność na przeciążenie chwilowe\nodporność na warunki instalacji\nstrata ciśnienia Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm\nZakres temperatur (-40 – +70) °C","reference":"PN-EN 12261 p. 5.2.1, 5.2.2, 5.2.3, 5.2.5, 5.2.6, 5.2.8, Załącznik B, 5.2.9","norm_bases":["PN-EN 12261 p. 5.2.1, 5.2.2, 5.2.3, 5.2.5, 5.2.6, 5.2.8, Załącznik B, 5.2.9"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze turbinowe E Właściwości metrologiczne:\nZakres:\nbłąd wskazania\npowtarzalność metrologiczna\nliniowość\nodporność na pozycję montażu gazomierza\nodporność na przeciążenie chwilowe\nodporność na warunki instalacji\nstrata ciśnienia Zakres strumienia objętości: (0,015 – 1 000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm\nZakres temperatur (-40 – +70) °C PN-EN 12261 p. 5.2.1, 5.2.2, 5.2.3, 5.2.5, 5.2.6, 5.2.8, Załącznik B, 5.2.9 Gazomierze turbinowe E Wlasciwosci metrologiczne:\nZakres:\nblad wskazania\npowtarzalnosc metrologiczna\nliniowosc\nodpornosc na pozycje montazu gazomierza\nodpornosc na przeciazenie chwilowe\nodpornosc na warunki instalacji\nstrata cisnienia Zakres strumienia objetosci: (0,015 – 1 000) m3/h\nMaksymalna srednica nominalna: DNmax = 200 mm\nZakres temperatur (-40 – +70) °C PN-EN 12261 p. 5.2.1, 5.2.2, 5.2.3, 5.2.5, 5.2.6, 5.2.8, Zalacznik B, 5.2.9","categories":["metrology"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Metrological properties:","parameters_en":[{"name":"indication error"},{"name":"metrological repeatability"},{"name":"linearity"},{"name":"resistance to the mounting position of the gas meter"},{"name":"resistance to momentary overload"},{"name":"resistance to installation conditions"},{"name":"pressure loss Volume flow rate range:","range":"(0,015 – 1 000) m3/h"},{"name":"Maximum nominal diameter: DNmax = 200 mm"},{"name":"Temperature range","range":"(-40 – +70) °C"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Turbine gas meters E Metrological properties: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. indication error metrological repeatability linearity resistance to the mounting position of the gas meter resistance to momentary overload resistance to installation conditions pressure loss Volume flow rate range: Maximum nominal diameter: DNmax = 200 mm Temperature range PN-EN 12261 p. 5.2.1, 5.2.2, 5.2.3, 5.2.5, 5.2.6, 5.2.8, Załącznik B, 5.2.9","test_object_en":"Turbine gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"涡轮式燃气表 E 计量性能： 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 示值误差 最大公称直径：DNmax = 200 mm 温度范围 PN-EN 12261 p. 5.2.1, 5.2.2, 5.2.3, 5.2.5, 5.2.6, 5.2.8, Załącznik B, 5.2.9","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"示值误差"},{"name":"powtarzalność metrologiczna"},{"name":"liniowość"},{"name":"odporność na pozycję montażu gazomierza"},{"name":"odporność na przeciążenie chwilowe"},{"name":"odporność na warunki instalacji"},{"name":"strata ciśnienia Zakres strumienia objętości:","range":"(0,015 – 1 000) m3/h"},{"name":"最大公称直径：DNmax = 200 mm"},{"name":"温度范围","range":"(-40 – +70) °C"}],"test_object_zh":"涡轮式燃气表 E","methodology_zh":"计量性能："},{"_id":"6a7d75f9441eff5f1564881f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze turbinowe E","methodology":"","parameters":[{"name":"odporność na temperaturę Zakres strumienia objętości:","range":"(0,015 – 400) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 80 mm"},{"name":"Zakres temperatur","range":"(-40 – +70) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nodporność na temperaturę Zakres strumienia objętości: (0,015 – 400) m3/h\nMaksymalna średnica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +70) °C","reference":"PN-EN 12261 p. 5.2.7","norm_bases":["PN-EN 12261 p. 5.2.7"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze turbinowe E Zakres:\nodporność na temperaturę Zakres strumienia objętości: (0,015 – 400) m3/h\nMaksymalna średnica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +70) °C PN-EN 12261 p. 5.2.7 Gazomierze turbinowe E Zakres:\nodpornosc na temperature Zakres strumienia objetosci: (0,015 – 400) m3/h\nMaksymalna srednica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +70) °C PN-EN 12261 p. 5.2.7","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","parameters_en":[{"name":"resistance to temperature Volume flow rate range:","range":"(0,015 – 400) m3/h"},{"name":"Maximum nominal diameter: DNmax = 80 mm"},{"name":"Temperature range","range":"(-40 – +70) °C"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Turbine gas meters E Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. resistance to temperature Volume flow rate range: Maximum nominal diameter: DNmax = 80 mm Temperature range PN-EN 12261 p. 5.2.7","test_object_en":"Turbine gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"涡轮式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 PN-EN 12261 p. 5.2.7","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"odporność na temperaturę Zakres strumienia objętości:","range":"(0,015 – 400) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 80 mm"},{"name":"温度范围","range":"(-40 – +70) °C"}],"test_object_zh":"涡轮式燃气表 E"},{"_id":"6a7d75f9441eff5f15648820","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze turbinowe E","methodology":"Cechy konstrukcyjne:","parameters":[{"name":"szczelność zewnętrzna (ciśnienie"},{"name":"maksymalne","range":"20 bar)"},{"name":"wytrzymałość okienka liczydła na uderzenie"},{"name":"odporność na transport i przechowywanie"},{"name":"odporność na korozję zewnętrzną"},{"name":"odporność na zarysowanie"},{"name":"przyleganie powłoki ochronnej"},{"name":"odporność na oddziaływanie mgły solnej"},{"name":"charakterystyka otworów impulsowych ciśnienia"},{"name":"wymiary otworów impulsowych ciśnienia"},{"name":"wymiary konstrukcyjne otworów do pomiaru temperatury"},{"name":"skuteczność układu smarowania gazomierza"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy konstrukcyjne:\nZakres:\nszczelność zewnętrzna (ciśnienie\nmaksymalne 20 bar)\nwytrzymałość okienka liczydła na uderzenie\nodporność na transport i przechowywanie\nodporność na korozję zewnętrzną\nodporność na zarysowanie\nprzyleganie powłoki ochronnej\nodporność na oddziaływanie mgły solnej\ncharakterystyka otworów impulsowych ciśnienia\nwymiary otworów impulsowych ciśnienia\nwymiary konstrukcyjne otworów do pomiaru temperatury\nskuteczność układu smarowania gazomierza","reference":"PN-EN 12261 p.6.2.3, 6.2.5, 6.2.6, 6.3.3, 6.3.3.1, 6.3.3.2, 6.3.3.3, 6.6.1, 6.6.1.1, 6.6.1.2, 6.6.2, 6.7","norm_bases":["PN-EN 12261 p.6.2.3, 6.2.5, 6.2.6, 6.3.3, 6.3.3.1, 6.3.3.2, 6.3.3.3, 6.6.1, 6.6.1.1, 6.6.1.2, 6.6.2, 6.7"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze turbinowe E Cechy konstrukcyjne:\nZakres:\nszczelność zewnętrzna (ciśnienie\nmaksymalne 20 bar)\nwytrzymałość okienka liczydła na uderzenie\nodporność na transport i przechowywanie\nodporność na korozję zewnętrzną\nodporność na zarysowanie\nprzyleganie powłoki ochronnej\nodporność na oddziaływanie mgły solnej\ncharakterystyka otworów impulsowych ciśnienia\nwymiary otworów impulsowych ciśnienia\nwymiary konstrukcyjne otworów do pomiaru temperatury\nskuteczność układu smarowania gazomierza PN-EN 12261 p.6.2.3, 6.2.5, 6.2.6, 6.3.3, 6.3.3.1, 6.3.3.2, 6.3.3.3, 6.6.1, 6.6.1.1, 6.6.1.2, 6.6.2, 6.7 Gazomierze turbinowe E Cechy konstrukcyjne:\nZakres:\nszczelnosc zewnetrzna (cisnienie\nmaksymalne 20 bar)\nwytrzymalosc okienka liczydla na uderzenie\nodpornosc na transport i przechowywanie\nodpornosc na korozje zewnetrzna\nodpornosc na zarysowanie\nprzyleganie powloki ochronnej\nodpornosc na oddzialywanie mgly solnej\ncharakterystyka otworow impulsowych cisnienia\nwymiary otworow impulsowych cisnienia\nwymiary konstrukcyjne otworow do pomiaru temperatury\nskutecznosc ukladu smarowania gazomierza PN-EN 12261 p.6.2.3, 6.2.5, 6.2.6, 6.3.3, 6.3.3.1, 6.3.3.2, 6.3.3.3, 6.6.1, 6.6.1.1, 6.6.1.2, 6.6.2, 6.7","categories":["petro"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Design features:","parameters_en":[{"name":"external tightness (pressure"},{"name":"maximum","range":"20 bar)"},{"name":"impact strength of the counter window"},{"name":"resistance to transport and storage"},{"name":"resistance to external corrosion"},{"name":"scratch resistance"},{"name":"adhesion of the protective coating"},{"name":"resistance to salt spray exposure"},{"name":"characteristics of the pressure impulse holes"},{"name":"dimensions of the pressure impulse holes"},{"name":"design dimensions of the temperature measurement openings"},{"name":"effectiveness of the gas meter lubrication system"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Turbine gas meters E Design features: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. external tightness (pressure maximum impact strength of the counter window resistance to transport and storage resistance to external corrosion scratch resistance adhesion of the protective coating resistance to salt spray exposure characteristics of the pressure impulse holes dimensions of the pressure impulse holes design dimensions of the temperature measurement openings effectiveness of the gas meter lubrication system PN-EN 12261 p.6.2.3, 6.2.5, 6.2.6, 6.3.3, 6.3.3.1, 6.3.3.2, 6.3.3.3, 6.6.1, 6.6.1.1, 6.6.1.2, 6.6.2, 6.7","test_object_en":"Turbine gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"涡轮式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 防护涂层的附着力 PN-EN 12261 p.6.2.3, 6.2.5, 6.2.6, 6.3.3, 6.3.3.1, 6.3.3.2, 6.3.3.3, 6.6.1, 6.6.1.1, 6.6.1.2, 6.6.2, 6.7","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"涡轮式燃气表 E","parameters_zh":[{"name":"szczelność zewnętrzna (ciśnienie"},{"name":"maksymalne","range":"20 bar)"},{"name":"wytrzymałość okienka liczydła na uderzenie"},{"name":"odporność na transport i przechowywanie"},{"name":"odporność na korozję zewnętrzną"},{"name":"odporność na zarysowanie"},{"name":"防护涂层的附着力"},{"name":"odporność na oddziaływanie mgły solnej"},{"name":"charakterystyka otworów impulsowych ciśnienia"},{"name":"wymiary otworów impulsowych ciśnienia"},{"name":"wymiary konstrukcyjne otworów do pomiaru temperatury"},{"name":"skuteczność układu smarowania gazomierza"}]},{"_id":"6a7d75f9441eff5f15648821","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze turbinowe E","methodology":"Wyjścia z gazomierza","parameters":[{"name":"czytelność wskazań liczydła"},{"name":"częstotliwość nadajników impulsów"},{"name":"rezystancja styków beznapięciowych"},{"name":"cechy konstrukcyjne elementu kontrolnego"}],"technique":null,"techniques":[],"computed":[],"activity":"Wyjścia z gazomierza\nZakres:\nczytelność wskazań liczydła\nczęstotliwość nadajników impulsów\nrezystancja styków beznapięciowych\ncechy konstrukcyjne elementu kontrolnego","reference":"PN-EN 12261 p.7.2.3, 7.3.1, 7.3.2.2, 7.5","norm_bases":["PN-EN 12261 p.7.2.3, 7.3.1, 7.3.2.2, 7.5"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze turbinowe E Wyjścia z gazomierza\nZakres:\nczytelność wskazań liczydła\nczęstotliwość nadajników impulsów\nrezystancja styków beznapięciowych\ncechy konstrukcyjne elementu kontrolnego PN-EN 12261 p.7.2.3, 7.3.1, 7.3.2.2, 7.5 Gazomierze turbinowe E Wyjscia z gazomierza\nZakres:\nczytelnosc wskazan liczydla\nczestotliwosc nadajnikow impulsow\nrezystancja stykow beznapieciowych\ncechy konstrukcyjne elementu kontrolnego PN-EN 12261 p.7.2.3, 7.3.1, 7.3.2.2, 7.5","categories":["other"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Gas meter outputs","parameters_en":[{"name":"legibility of counter readings"},{"name":"frequency of pulse transmitters"},{"name":"resistance of voltage-free contacts"},{"name":"design features of the checking element"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Turbine gas meters E Gas meter outputs Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. legibility of counter readings frequency of pulse transmitters resistance of voltage-free contacts design features of the checking element PN-EN 12261 p.7.2.3, 7.3.1, 7.3.2.2, 7.5","test_object_en":"Turbine gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"涡轮式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12261 p.7.2.3, 7.3.1, 7.3.2.2, 7.5","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"涡轮式燃气表 E"},{"_id":"6a7d75f9441eff5f15648822","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze rotorowe E","methodology":"Właściwości metrologiczne:","parameters":[{"name":"błąd wskazania"},{"name":"strata ciśnienia"},{"name":"powtarzalność metrologiczna Zakres strumienia objętości:","range":"(0,015 – 1000) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 200 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości metrologiczne:\nZakres:\nbłąd wskazania\nstrata ciśnienia\npowtarzalność metrologiczna Zakres strumienia objętości: (0,015 – 1000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm","reference":"PN-EN 12480","norm_bases":["PN-EN 12480"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze rotorowe E Właściwości metrologiczne:\nZakres:\nbłąd wskazania\nstrata ciśnienia\npowtarzalność metrologiczna Zakres strumienia objętości: (0,015 – 1000) m3/h\nMaksymalna średnica nominalna: DNmax = 200 mm PN-EN 12480 Gazomierze rotorowe E Wlasciwosci metrologiczne:\nZakres:\nblad wskazania\nstrata cisnienia\npowtarzalnosc metrologiczna Zakres strumienia objetosci: (0,015 – 1000) m3/h\nMaksymalna srednica nominalna: DNmax = 200 mm PN-EN 12480","categories":["metrology"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Metrological properties:","parameters_en":[{"name":"indication error"},{"name":"pressure loss"},{"name":"metrological repeatability Volume flow range:","range":"(0,015 – 1000) m3/h"},{"name":"Maximum nominal diameter: DNmax = 200 mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Rotary gas meters E Metrological properties: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. indication error pressure loss metrological repeatability Volume flow range: Maximum nominal diameter: DNmax = 200 mm PN-EN 12480","test_object_en":"Rotary gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"腰轮式燃气表 E 计量性能： 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 示值误差 压力损失 最大公称直径：DNmax = 200 mm PN-EN 12480","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"示值误差"},{"name":"压力损失"},{"name":"powtarzalność metrologiczna Zakres strumienia objętości:","range":"(0,015 – 1000) m3/h"},{"name":"最大公称直径：DNmax = 200 mm"}],"test_object_zh":"腰轮式燃气表 E","methodology_zh":"计量性能："},{"_id":"6a7d75f9441eff5f15648823","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze rotorowe E","methodology":"Budowa i materiały:","parameters":[{"name":"odporność na korozję zewnętrzną"},{"name":"odporność na zarysowanie"},{"name":"przyleganie powłoki ochronnej"},{"name":"wytrzymałość na prędkość zmiany ciśnienia"},{"name":"szczelność zewnętrzna"},{"name":"odporność na przeciążenie"},{"name":"wymiary przyłączy gazomierza"},{"name":"wymiary otworów impulsowych ciśnienia"},{"name":"wymiary otworów temperaturowych"},{"name":"odporność na transport i przechowywanie"},{"name":"odporność na wysoką temperaturę Maksymalne wymiary obiektów:","range":"(520x450x650) mm"},{"name":"Temperatura maksymalna","range":"650 °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Budowa i materiały:\nZakres:\nodporność na korozję zewnętrzną\nodporność na zarysowanie\nprzyleganie powłoki ochronnej\nwytrzymałość na prędkość zmiany ciśnienia\nszczelność zewnętrzna\nodporność na przeciążenie\nwymiary przyłączy gazomierza\nwymiary otworów impulsowych ciśnienia\nwymiary otworów temperaturowych\nodporność na transport i przechowywanie\nodporność na wysoką temperaturę Maksymalne wymiary obiektów: (520x450x650) mm\nTemperatura maksymalna 650 °C","reference":"PN-EN 12480","norm_bases":["PN-EN 12480"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze rotorowe E Budowa i materiały:\nZakres:\nodporność na korozję zewnętrzną\nodporność na zarysowanie\nprzyleganie powłoki ochronnej\nwytrzymałość na prędkość zmiany ciśnienia\nszczelność zewnętrzna\nodporność na przeciążenie\nwymiary przyłączy gazomierza\nwymiary otworów impulsowych ciśnienia\nwymiary otworów temperaturowych\nodporność na transport i przechowywanie\nodporność na wysoką temperaturę Maksymalne wymiary obiektów: (520x450x650) mm\nTemperatura maksymalna 650 °C PN-EN 12480 Gazomierze rotorowe E Budowa i materialy:\nZakres:\nodpornosc na korozje zewnetrzna\nodpornosc na zarysowanie\nprzyleganie powloki ochronnej\nwytrzymalosc na predkosc zmiany cisnienia\nszczelnosc zewnetrzna\nodpornosc na przeciazenie\nwymiary przylaczy gazomierza\nwymiary otworow impulsowych cisnienia\nwymiary otworow temperaturowych\nodpornosc na transport i przechowywanie\nodpornosc na wysoka temperature Maksymalne wymiary obiektow: (520x450x650) mm\nTemperatura maksymalna 650 °C PN-EN 12480","categories":["materials"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Construction and materials:","parameters_en":[{"name":"resistance to external corrosion"},{"name":"scratch resistance"},{"name":"adhesion of the protective coating"},{"name":"resistance to the rate of pressure change"},{"name":"external tightness"},{"name":"resistance to overload"},{"name":"dimensions of the gas meter connections"},{"name":"dimensions of the pressure impulse holes"},{"name":"dimensions of the temperature openings"},{"name":"resistance to transport and storage"},{"name":"resistance to high temperature Maximum object dimensions:","range":"(520x450x650) mm"},{"name":"Maximum temperature","range":"650 °C"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Rotary gas meters E Construction and materials: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. resistance to external corrosion scratch resistance adhesion of the protective coating resistance to the rate of pressure change external tightness resistance to overload dimensions of the gas meter connections dimensions of the pressure impulse holes dimensions of the temperature openings resistance to transport and storage resistance to high temperature Maximum object dimensions: Maximum temperature PN-EN 12480","test_object_en":"Rotary gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"腰轮式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 防护涂层的附着力 最高温度 PN-EN 12480","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"腰轮式燃气表 E","parameters_zh":[{"name":"odporność na korozję zewnętrzną"},{"name":"odporność na zarysowanie"},{"name":"防护涂层的附着力"},{"name":"wytrzymałość na prędkość zmiany ciśnienia"},{"name":"szczelność zewnętrzna"},{"name":"odporność na przeciążenie"},{"name":"wymiary przyłączy gazomierza"},{"name":"wymiary otworów impulsowych ciśnienia"},{"name":"wymiary otworów temperaturowych"},{"name":"odporność na transport i przechowywanie"},{"name":"odporność na wysoką temperaturę Maksymalne wymiary obiektów:","range":"(520x450x650) mm"},{"name":"最高温度","range":"650 °C"}]},{"_id":"6a7d75f9441eff5f15648824","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze rotorowe E","methodology":"","parameters":[{"name":"odporność na temperaturę Zakres strumienia objętości:","range":"(0,015 – 400) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 80 mm"},{"name":"Zakres temperatur","range":"(-40 – +70) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nodporność na temperaturę Zakres strumienia objętości: (0,015 – 400) m3/h\nMaksymalna średnica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +70) °C","reference":"PN-EN 12480","norm_bases":["PN-EN 12480"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze rotorowe E Zakres:\nodporność na temperaturę Zakres strumienia objętości: (0,015 – 400) m3/h\nMaksymalna średnica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +70) °C PN-EN 12480 Gazomierze rotorowe E Zakres:\nodpornosc na temperature Zakres strumienia objetosci: (0,015 – 400) m3/h\nMaksymalna srednica nominalna: DNmax = 80 mm\nZakres temperatur (-40 – +70) °C PN-EN 12480","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","parameters_en":[{"name":"resistance to temperature Volume flow rate range:","range":"(0,015 – 400) m3/h"},{"name":"Maximum nominal diameter: DNmax = 80 mm"},{"name":"Temperature range","range":"(-40 – +70) °C"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Rotary gas meters E Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. resistance to temperature Volume flow rate range: Maximum nominal diameter: DNmax = 80 mm Temperature range PN-EN 12480","test_object_en":"Rotary gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"腰轮式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 PN-EN 12480","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"odporność na temperaturę Zakres strumienia objętości:","range":"(0,015 – 400) m3/h"},{"name":"Maksymalna średnica nominalna: DNmax = 80 mm"},{"name":"温度范围","range":"(-40 – +70) °C"}],"test_object_zh":"腰轮式燃气表 E"},{"_id":"6a7d75f9441eff5f15648825","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze rotorowe E","methodology":"Wyjścia z gazomierza","parameters":[{"name":"cechy konstrukcyjne liczydła oraz elementu kontrolnego (ilość cyfr, działka elementarna, długość działki, kąt obrotu)"},{"name":"cechy konstrukcyjne okienka liczydła"},{"name":"odporność okienka liczydła na uderzenie"},{"name":"sztywność okienka liczydła"},{"name":"częstotliwość nadajników impulsów"},{"name":"rezystancja styków beznapięciowych"}],"technique":null,"techniques":[],"computed":[],"activity":"Wyjścia z gazomierza\nZakres:\ncechy konstrukcyjne liczydła oraz elementu kontrolnego (ilość cyfr, działka elementarna, długość działki, kąt obrotu)\ncechy konstrukcyjne okienka liczydła\nodporność okienka liczydła na uderzenie\nsztywność okienka liczydła\nczęstotliwość nadajników impulsów\nrezystancja styków beznapięciowych","reference":"PN-EN 12480","norm_bases":["PN-EN 12480"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze rotorowe E Wyjścia z gazomierza\nZakres:\ncechy konstrukcyjne liczydła oraz elementu kontrolnego (ilość cyfr, działka elementarna, długość działki, kąt obrotu)\ncechy konstrukcyjne okienka liczydła\nodporność okienka liczydła na uderzenie\nsztywność okienka liczydła\nczęstotliwość nadajników impulsów\nrezystancja styków beznapięciowych PN-EN 12480 Gazomierze rotorowe E Wyjscia z gazomierza\nZakres:\ncechy konstrukcyjne liczydla oraz elementu kontrolnego (ilosc cyfr, dzialka elementarna, dlugosc dzialki, kat obrotu)\ncechy konstrukcyjne okienka liczydla\nodpornosc okienka liczydla na uderzenie\nsztywnosc okienka liczydla\nczestotliwosc nadajnikow impulsow\nrezystancja stykow beznapieciowych PN-EN 12480","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Gas meter outputs","parameters_en":[{"name":"design features of the counter and the checking element (number of digits, scale interval, scale interval length, angle of rotation)"},{"name":"design features of the counter window"},{"name":"impact resistance of the counter window"},{"name":"stiffness of the counter window"},{"name":"frequency of pulse transmitters"},{"name":"resistance of voltage-free contacts"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Rotary gas meters E Gas meter outputs Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. design features of the counter and the checking element (number of digits, scale interval, scale interval length, angle of rotation) design features of the counter window impact resistance of the counter window stiffness of the counter window frequency of pulse transmitters resistance of voltage-free contacts PN-EN 12480","test_object_en":"Rotary gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"腰轮式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12480","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"腰轮式燃气表 E"},{"_id":"6a7d75f9441eff5f15648826","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazomierze rotorowe E","methodology":"Trwałość, Maksymalny strumień objętości: 1000 m3/h","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość, Maksymalny strumień objętości: 1000 m3/h","reference":"PN-EN 12480","norm_bases":["PN-EN 12480"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Gazomierze rotorowe E Trwałość, Maksymalny strumień objętości: 1000 m3/h PN-EN 12480 Gazomierze rotorowe E Trwalosc, Maksymalny strumien objetosci: 1000 m3/h PN-EN 12480","categories":["other"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Durability, Maximum volume flow rate: 1000 m3/h","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Rotary gas meters E Durability, Maximum volume flow rate: 1000 m3/h Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12480","test_object_en":"Rotary gas meters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"腰轮式燃气表 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12480","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"腰轮式燃气表 E"},{"_id":"6a7d75f9441eff5f15648827","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki metaliczne, organiczne, anodowe tlenkowe E","methodology":"Odporność na mgłę solną","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na mgłę solną","reference":"PN-EN ISO 9227","norm_bases":["PN-EN ISO 9227"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki metaliczne, organiczne, anodowe tlenkowe E Odporność na mgłę solną PN-EN ISO 9227 Powloki metaliczne, organiczne, anodowe tlenkowe E Odpornosc na mgle solna PN-EN ISO 9227","categories":["materials"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to salt fog","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metallic, organic and anodic oxide coatings E Resistance to salt fog Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 9227","test_object_en":"Metallic, organic and anodic oxide coatings E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 9227","lab_section_zh":"流量计量实验室（GM-1）"},{"_id":"6a7d75f9441eff5f15648828","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki, systemy powłok oraz materiały odporne i nieodporne na korozję E","methodology":"Odporność na wilgoć, Kondensacja ciągła","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wilgoć, Kondensacja ciągła","reference":"PN-EN ISO 6270-1","norm_bases":["PN-EN ISO 6270-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki, systemy powłok oraz materiały odporne i nieodporne na korozję E Odporność na wilgoć, Kondensacja ciągła PN-EN ISO 6270-1 Powloki, systemy powlok oraz materialy odporne i nieodporne na korozje E Odpornosc na wilgoc, Kondensacja ciagla PN-EN ISO 6270-1","categories":["materials"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Humidity resistance, Continuous condensation","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Coatings, coating systems and materials resistant and non-resistant to corrosion E Humidity resistance, Continuous condensation Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 6270-1","test_object_en":"Coatings, coating systems and materials resistant and non-resistant to corrosion E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 6270-1","lab_section_zh":"流量计量实验室（GM-1）"},{"_id":"6a7d75f9441eff5f15648829","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Dokładność wskazań w warunkach odniesienia","parameters":[{"name":"Zakres temperatury","range":"(-40 – +125) °C"},{"name":"Zakres ciśnienia","range":"(0,4 – 135) bar abs"}],"technique":null,"techniques":[],"computed":[],"activity":"Dokładność wskazań w warunkach odniesienia\nZakres:\nZakres temperatury (-40 – +125) °C\nZakres ciśnienia (0,4 – 135) bar abs","reference":"PN-EN 12405-1 p.A2","norm_bases":["PN-EN 12405-1 p.A2"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Dokładność wskazań w warunkach odniesienia\nZakres:\nZakres temperatury (-40 – +125) °C\nZakres ciśnienia (0,4 – 135) bar abs PN-EN 12405-1 p.A2 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Dokladnosc wskazan w warunkach odniesienia\nZakres:\nZakres temperatury (-40 – +125) °C\nZakres cisnienia (0,4 – 135) bar abs PN-EN 12405-1 p.A2","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Accuracy of indication under reference conditions","parameters_en":[{"name":"Temperature range","range":"(-40 – +125) °C"},{"name":"Pressure range","range":"(0,4 – 135) bar abs"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Accuracy of indication under reference conditions Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Temperature range Pressure range PN-EN 12405-1 p.A2","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 压力范围 PN-EN 12405-1 p.A2","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E","parameters_zh":[{"name":"温度范围","range":"(-40 – +125) °C"},{"name":"压力范围","range":"(0,4 – 135) bar abs"}]},{"_id":"6a7d75f9441eff5f1564882a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ temperatury otoczenia na właściwości metrologiczne","parameters":[{"name":"Zakres temperatury","range":"(-70 – +70) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ temperatury otoczenia na właściwości metrologiczne\nZakres temperatury (-70 – +70) °C","reference":"PN-EN 12405-1 p.A3 | PN-EN 60068-2-1 | PN-EN 60068-2-2 | PN-EN 60068-3-1","norm_bases":["PN-EN 12405-1 p.A3","PN-EN 60068-2-1","PN-EN 60068-2-2","PN-EN 60068-3-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ temperatury otoczenia na właściwości metrologiczne\nZakres temperatury (-70 – +70) °C PN-EN 12405-1 p.A3 | PN-EN 60068-2-1 | PN-EN 60068-2-2 | PN-EN 60068-3-1 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw temperatury otoczenia na wlasciwosci metrologiczne\nZakres temperatury (-70 – +70) °C PN-EN 12405-1 p.A3 | PN-EN 60068-2-1 | PN-EN 60068-2-2 | PN-EN 60068-3-1","categories":["metrology"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of ambient temperature on metrological properties","parameters_en":[{"name":"Temperature range","range":"(-70 – +70) °C"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of ambient temperature on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Temperature range PN-EN 12405-1 p.A3 | PN-EN 60068-2-1 | PN-EN 60068-2-2 | PN-EN 60068-3-1","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 PN-EN 12405-1 p.A3 | PN-EN 60068-2-1 | PN-EN 60068-2-2 | PN-EN 60068-3-1","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E","parameters_zh":[{"name":"温度范围","range":"(-70 – +70) °C"}]},{"_id":"6a7d75f9441eff5f1564882b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ oddziaływania stałego wilgotnego gorąca na właściwości metrologiczne","parameters":[{"name":"Zakres temperatury","range":"(-40 – +55) °C"},{"name":"Wilgotność wzgl.","range":"(10 – 98) %"}],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ oddziaływania stałego wilgotnego gorąca na właściwości metrologiczne\nZakres:\nZakres temperatury (-40 – +55) °C\nWilgotność wzgl. (10 – 98) %","reference":"PN-EN 12405-1 p.A4 | PN-EN 60068-2-78","norm_bases":["PN-EN 12405-1 p.A4","PN-EN 60068-2-78"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ oddziaływania stałego wilgotnego gorąca na właściwości metrologiczne\nZakres:\nZakres temperatury (-40 – +55) °C\nWilgotność wzgl. (10 – 98) % PN-EN 12405-1 p.A4 | PN-EN 60068-2-78 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw oddzialywania stalego wilgotnego goraca na wlasciwosci metrologiczne\nZakres:\nZakres temperatury (-40 – +55) °C\nWilgotnosc wzgl. (10 – 98) % PN-EN 12405-1 p.A4 | PN-EN 60068-2-78","categories":["metrology"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of steady-state damp heat on metrological properties","parameters_en":[{"name":"Temperature range","range":"(-40 – +55) °C"},{"name":"Rel. humidity","range":"(10 – 98) %"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of steady-state damp heat on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Temperature range Rel. humidity PN-EN 12405-1 p.A4 | PN-EN 60068-2-78","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 相对湿度 PN-EN 12405-1 p.A4 | PN-EN 60068-2-78","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E","parameters_zh":[{"name":"温度范围","range":"(-40 – +55) °C"},{"name":"相对湿度","range":"(10 – 98) %"}]},{"_id":"6a7d75f9441eff5f1564882c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ oddziaływania cyklicznego wilgotnego gorąca na właściwości metrologiczne","parameters":[{"name":"Zakres temperatury","range":"(-40 – +55) °C"},{"name":"Wilgotność wzgl.","range":"(10 – 98) %"}],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ oddziaływania cyklicznego wilgotnego gorąca na właściwości metrologiczne\nZakres:\nZakres temperatury (-40 – +55) °C\nWilgotność wzgl. (10 – 98) %","reference":"PN-EN 12405-1 p.A5 | PN-EN 60068-2-30","norm_bases":["PN-EN 12405-1 p.A5","PN-EN 60068-2-30"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ oddziaływania cyklicznego wilgotnego gorąca na właściwości metrologiczne\nZakres:\nZakres temperatury (-40 – +55) °C\nWilgotność wzgl. (10 – 98) % PN-EN 12405-1 p.A5 | PN-EN 60068-2-30 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw oddzialywania cyklicznego wilgotnego goraca na wlasciwosci metrologiczne\nZakres:\nZakres temperatury (-40 – +55) °C\nWilgotnosc wzgl. (10 – 98) % PN-EN 12405-1 p.A5 | PN-EN 60068-2-30","categories":["metrology"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of cyclic damp heat on metrological properties","parameters_en":[{"name":"Temperature range","range":"(-40 – +55) °C"},{"name":"Rel. humidity","range":"(10 – 98) %"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of cyclic damp heat on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Temperature range Rel. humidity PN-EN 12405-1 p.A5 | PN-EN 60068-2-30","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 温度范围 相对湿度 PN-EN 12405-1 p.A5 | PN-EN 60068-2-30","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E","parameters_zh":[{"name":"温度范围","range":"(-40 – +55) °C"},{"name":"相对湿度","range":"(10 – 98) %"}]},{"_id":"6a7d75f9441eff5f1564882d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ zmian zasilania elektrycznego na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ zmian zasilania elektrycznego na właściwości metrologiczne","reference":"PN-EN 12405-1 p.A6 | PN-EN 61000-4:11","norm_bases":["PN-EN 12405-1 p.A6","PN-EN 61000-4:11"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ zmian zasilania elektrycznego na właściwości metrologiczne PN-EN 12405-1 p.A6 | PN-EN 61000-4:11 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw zmian zasilania elektrycznego na wlasciwosci metrologiczne PN-EN 12405-1 p.A6 | PN-EN 61000-4:11","categories":["metrology"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of variations in the electrical supply on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of variations in the electrical supply on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.A6 | PN-EN 61000-4:11","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.A6 | PN-EN 61000-4:11","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f1564882e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ krótkotrwałych spadków zasilania na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ krótkotrwałych spadków zasilania na właściwości metrologiczne","reference":"PN-EN 12405-1 p.A7","norm_bases":["PN-EN 12405-1 p.A7"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ krótkotrwałych spadków zasilania na właściwości metrologiczne PN-EN 12405-1 p.A7 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw krotkotrwalych spadkow zasilania na wlasciwosci metrologiczne PN-EN 12405-1 p.A7","categories":["metrology"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of short-time power reductions on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of short-time power reductions on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.A7","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.A7","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f1564882f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ serii szybkich elektrycznych stanów przejściowych na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ serii szybkich elektrycznych stanów przejściowych na właściwości metrologiczne","reference":"PN-EN 12405-1 p.A8","norm_bases":["PN-EN 12405-1 p.A8"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ serii szybkich elektrycznych stanów przejściowych na właściwości metrologiczne PN-EN 12405-1 p.A8 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw serii szybkich elektrycznych stanow przejsciowych na wlasciwosci metrologiczne PN-EN 12405-1 p.A8","categories":["metrology"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of electrical fast transients/bursts on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of electrical fast transients/bursts on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.A8","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.A8","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648830","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ wyładowań elektrostatycznych na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ wyładowań elektrostatycznych na właściwości metrologiczne","reference":"PN-EN 12405-1 p.A10","norm_bases":["PN-EN 12405-1 p.A10"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ wyładowań elektrostatycznych na właściwości metrologiczne PN-EN 12405-1 p.A10 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw wyladowan elektrostatycznych na wlasciwosci metrologiczne PN-EN 12405-1 p.A10","categories":["metrology"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of electrostatic discharges on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of electrostatic discharges on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.A10","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.A10","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648831","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ wibracji na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ wibracji na właściwości metrologiczne","reference":"PN-EN 12405-1 p.A12","norm_bases":["PN-EN 12405-1 p.A12"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ wibracji na właściwości metrologiczne PN-EN 12405-1 p.A12 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw wibracji na wlasciwosci metrologiczne PN-EN 12405-1 p.A12","categories":["metrology"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of vibration on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of vibration on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.A12","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.A12","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648832","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ oddziaływania udarów na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ oddziaływania udarów na właściwości metrologiczne","reference":"PN-EN 12405-1 p.A13 | PN-EN 60068-2-31","norm_bases":["PN-EN 12405-1 p.A13","PN-EN 60068-2-31"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ oddziaływania udarów na właściwości metrologiczne PN-EN 12405-1 p.A13 | PN-EN 60068-2-31 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw oddzialywania udarow na wlasciwosci metrologiczne PN-EN 12405-1 p.A13 | PN-EN 60068-2-31","categories":["metrology"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of mechanical shocks on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of mechanical shocks on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.A13 | PN-EN 60068-2-31","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.A13 | PN-EN 60068-2-31","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648833","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Trwałość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość","reference":"PN-EN 12405-1 p.A15","norm_bases":["PN-EN 12405-1 p.A15"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Trwałość PN-EN 12405-1 p.A15 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Trwalosc PN-EN 12405-1 p.A15","categories":["other"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Durability","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Durability Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.A15","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 耐久性 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.A15","lab_section_zh":"流量计量实验室（GM-1）","methodology_zh":"耐久性","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648834","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Zadziałanie alarmów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zadziałanie alarmów","reference":"PN-EN 12405-1 p.A16","norm_bases":["PN-EN 12405-1 p.A16"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Zadziałanie alarmów PN-EN 12405-1 p.A16 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Zadzialanie alarmow PN-EN 12405-1 p.A16","categories":["other"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Operation of the alarms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Operation of the alarms Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.A16","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.A16","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648835","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Powtarzalność metrologiczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Powtarzalność metrologiczna","reference":"PN-EN 12405-1 p.A17","norm_bases":["PN-EN 12405-1 p.A17"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Powtarzalność metrologiczna PN-EN 12405-1 p.A17 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Powtarzalnosc metrologiczna PN-EN 12405-1 p.A17","categories":["metrology"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Metrological repeatability","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Metrological repeatability Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.A17","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.A17","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648836","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ pola elektromagnetycznego na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ pola elektromagnetycznego na właściwości metrologiczne","reference":"PN-EN 12405-1 p. A9","norm_bases":["PN-EN 12405-1 p. A9"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ pola elektromagnetycznego na właściwości metrologiczne PN-EN 12405-1 p. A9 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw pola elektromagnetycznego na wlasciwosci metrologiczne PN-EN 12405-1 p. A9","categories":["metrology"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of electromagnetic fields on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of electromagnetic fields on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p. A9","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p. A9","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648837","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ zaburzeń przewodzonych indukowanych przez pola o częstotliwości radiowej na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ zaburzeń przewodzonych indukowanych przez pola o częstotliwości radiowej na właściwości metrologiczne","reference":"PN-EN 12405-1 p. A9","norm_bases":["PN-EN 12405-1 p. A9"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ zaburzeń przewodzonych indukowanych przez pola o częstotliwości radiowej na właściwości metrologiczne PN-EN 12405-1 p. A9 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw zaburzen przewodzonych indukowanych przez pola o czestotliwosci radiowej na wlasciwosci metrologiczne PN-EN 12405-1 p. A9","categories":["metrology"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of conducted disturbances induced by radio-frequency fields on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of conducted disturbances induced by radio-frequency fields on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p. A9","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p. A9","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648838","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ zapadów napięcia, krótkich przerw i zmian napięcia (przyłącze DC) na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ zapadów napięcia, krótkich przerw i zmian napięcia (przyłącze DC) na właściwości metrologiczne","reference":"PN-EN 12405-1 p. A18","norm_bases":["PN-EN 12405-1 p. A18"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ zapadów napięcia, krótkich przerw i zmian napięcia (przyłącze DC) na właściwości metrologiczne PN-EN 12405-1 p. A18 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw zapadow napiecia, krotkich przerw i zmian napiecia (przylacze DC) na wlasciwosci metrologiczne PN-EN 12405-1 p. A18","categories":["metrology"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of voltage dips, short interruptions and voltage variations (DC input) on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of voltage dips, short interruptions and voltage variations (DC input) on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p. A18","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p. A18","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f15648839","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ udarów na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ udarów na właściwości metrologiczne","reference":"PN-EN 12405-1 p. A19","norm_bases":["PN-EN 12405-1 p. A19"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ udarów na właściwości metrologiczne PN-EN 12405-1 p. A19 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw udarow na wlasciwosci metrologiczne PN-EN 12405-1 p. A19","categories":["metrology"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of shocks on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of shocks on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p. A19","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p. A19","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f1564883a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E","methodology":"Wpływ pola magnetycznego o częstotliwości sieci na właściwości metrologiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ pola magnetycznego o częstotliwości sieci na właściwości metrologiczne","reference":"PN-EN 12405-1 p. A20","norm_bases":["PN-EN 12405-1 p. A20"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia, przetworniki temperatury E Wpływ pola magnetycznego o częstotliwości sieci na właściwości metrologiczne PN-EN 12405-1 p. A20 Przeliczniki do gazomierzy, przetworniki cisnienia, przetworniki temperatury E Wplyw pola magnetycznego o czestotliwosci sieci na wlasciwosci metrologiczne PN-EN 12405-1 p. A20","categories":["metrology"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of power-frequency magnetic fields on metrological properties","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers, temperature transducers E Effect of power-frequency magnetic fields on metrological properties Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p. A20","test_object_en":"Gas volume converters, pressure transducers, temperature transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气表换算仪、压力变送器、温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p. A20","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"燃气表换算仪、压力变送器、温度变送器 E"},{"_id":"6a7d75f9441eff5f1564883b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia E","methodology":"Odporność na obciążanie ciśnieniem","parameters":[{"name":"Zakres ciśnienia","range":"(0,4 – 135) bar abs"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na obciążanie ciśnieniem\nZakres ciśnienia (0,4 – 135) bar abs","reference":"PN-EN 12405-1 p.A11","norm_bases":["PN-EN 12405-1 p.A11"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia E Odporność na obciążanie ciśnieniem\nZakres ciśnienia (0,4 – 135) bar abs PN-EN 12405-1 p.A11 Przeliczniki do gazomierzy, przetworniki cisnienia E Odpornosc na obciazanie cisnieniem\nZakres cisnienia (0,4 – 135) bar abs PN-EN 12405-1 p.A11","categories":["other"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to pressure loading","parameters_en":[{"name":"Pressure range","range":"(0,4 – 135) bar abs"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers E Resistance to pressure loading Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Pressure range PN-EN 12405-1 p.A11","test_object_en":"Gas volume converters, pressure transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 压力范围 PN-EN 12405-1 p.A11","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"压力范围","range":"(0,4 – 135) bar abs"}]},{"_id":"6a7d75f9441eff5f1564883c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, przetworniki ciśnienia E","methodology":"Wytrzymałość mechaniczna na obciążenie ciśnieniem","parameters":[{"name":"Zakres ciśnienia","range":"(0,4 – 135) bar abs"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość mechaniczna na obciążenie ciśnieniem\nZakres ciśnienia (0,4 – 135) bar abs","reference":"PN-EN 12405-1 p.A14","norm_bases":["PN-EN 12405-1 p.A14"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy, przetworniki ciśnienia E Wytrzymałość mechaniczna na obciążenie ciśnieniem\nZakres ciśnienia (0,4 – 135) bar abs PN-EN 12405-1 p.A14 Przeliczniki do gazomierzy, przetworniki cisnienia E Wytrzymalosc mechaniczna na obciazenie cisnieniem\nZakres cisnienia (0,4 – 135) bar abs PN-EN 12405-1 p.A14","categories":["other"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Mechanical strength under pressure loading","parameters_en":[{"name":"Pressure range","range":"(0,4 – 135) bar abs"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters, pressure transducers E Mechanical strength under pressure loading Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Pressure range PN-EN 12405-1 p.A14","test_object_en":"Gas volume converters, pressure transducers E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 压力范围 PN-EN 12405-1 p.A14","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"压力范围","range":"(0,4 – 135) bar abs"}]},{"_id":"6a7d75f9441eff5f1564883d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy E","methodology":"Cechy i właściwości konstrukcyjne i użytkowe:","parameters":[{"name":"dokładność"},{"name":"trwałość"},{"name":"działanie alarmów"},{"name":"powtarzalność"},{"name":"odporność na: temperaturę otoczenia"},{"name":"Zakres temperatury","range":"(-40 – +70) °C"},{"name":"wilgotne gorąco stałe"},{"name":"wilgotne gorąco cykliczne"},{"name":"Zakres temperatury","range":"(-40 – +70) °C"},{"name":"wilgotność wzgl.","range":"(10 – 98) %"},{"name":"krótkotrwałe spadki zasilania"},{"name":"serie szybkich elektrycznych stanów przejściowych"},{"name":"wyładowania elektrostatyczne"},{"name":"przeciążenie ciśnieniem"},{"name":"wpływ wibracji"},{"name":"udary"},{"name":"przeciążenie ciśnieniem (mechaniczne)"},{"name":"Zakres ciśnienia","range":"(0,4 – 135) bar abs"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości konstrukcyjne i użytkowe:\nZakres:\ndokładność\ntrwałość\ndziałanie alarmów\npowtarzalność\nodporność na: temperaturę otoczenia\nZakres temperatury (-40 – +70) °C\nwilgotne gorąco stałe\nwilgotne gorąco cykliczne\nZakres temperatury (-40 – +70) °C\nwilgotność wzgl. (10 – 98) %\nkrótkotrwałe spadki zasilania\nserie szybkich elektrycznych stanów przejściowych\nwyładowania elektrostatyczne\nprzeciążenie ciśnieniem\nwpływ wibracji\nudary\nprzeciążenie ciśnieniem (mechaniczne)\nZakres ciśnienia (0,4 – 135) bar abs","reference":"PN-EN 12405-1 p.9.1, 9,2","norm_bases":["PN-EN 12405-1 p.9.1, 9,2"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przeliczniki do gazomierzy E Cechy i właściwości konstrukcyjne i użytkowe:\nZakres:\ndokładność\ntrwałość\ndziałanie alarmów\npowtarzalność\nodporność na: temperaturę otoczenia\nZakres temperatury (-40 – +70) °C\nwilgotne gorąco stałe\nwilgotne gorąco cykliczne\nZakres temperatury (-40 – +70) °C\nwilgotność wzgl. (10 – 98) %\nkrótkotrwałe spadki zasilania\nserie szybkich elektrycznych stanów przejściowych\nwyładowania elektrostatyczne\nprzeciążenie ciśnieniem\nwpływ wibracji\nudary\nprzeciążenie ciśnieniem (mechaniczne)\nZakres ciśnienia (0,4 – 135) bar abs PN-EN 12405-1 p.9.1, 9,2 Przeliczniki do gazomierzy E Cechy i wlasciwosci konstrukcyjne i uzytkowe:\nZakres:\ndokladnosc\ntrwalosc\ndzialanie alarmow\npowtarzalnosc\nodpornosc na: temperature otoczenia\nZakres temperatury (-40 – +70) °C\nwilgotne goraco stale\nwilgotne goraco cykliczne\nZakres temperatury (-40 – +70) °C\nwilgotnosc wzgl. (10 – 98) %\nkrotkotrwale spadki zasilania\nserie szybkich elektrycznych stanow przejsciowych\nwyladowania elektrostatyczne\nprzeciazenie cisnieniem\nwplyw wibracji\nudary\nprzeciazenie cisnieniem (mechaniczne)\nZakres cisnienia (0,4 – 135) bar abs PN-EN 12405-1 p.9.1, 9,2","categories":["other"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Design and performance characteristics and properties:","parameters_en":[{"name":"accuracy"},{"name":"durability"},{"name":"operation of alarms"},{"name":"repeatability"},{"name":"resistance to: ambient temperature"},{"name":"Temperature range","range":"(-40 – +70) °C"},{"name":"damp heat steady state"},{"name":"damp heat cyclic"},{"name":"Temperature range","range":"(-40 – +70) °C"},{"name":"rel. humidity","range":"(10 – 98) %"},{"name":"short-term supply voltage dips"},{"name":"electrical fast transient/burst"},{"name":"electrostatic discharge"},{"name":"pressure overload"},{"name":"effect of vibration"},{"name":"impacts"},{"name":"pressure overload (mechanical)"},{"name":"Pressure range","range":"(0,4 – 135) bar abs"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas volume converters E Design and performance characteristics and properties: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. accuracy durability operation of alarms repeatability resistance to: ambient temperature Temperature range damp heat steady state damp heat cyclic Temperature range rel. humidity short-term supply voltage dips electrical fast transient/burst electrostatic discharge pressure overload effect of vibration impacts pressure overload (mechanical) Pressure range PN-EN 12405-1 p.9.1, 9,2","test_object_en":"Gas volume converters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 准确度 耐久性 报警动作 重复性 温度范围 恒定湿热 交变湿热 温度范围 短时供电跌落 电快速瞬变脉冲群 静电放电 振动影响 冲击 压力范围 PN-EN 12405-1 p.9.1, 9,2","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"准确度"},{"name":"耐久性"},{"name":"报警动作"},{"name":"重复性"},{"name":"odporność na: temperaturę otoczenia"},{"name":"温度范围","range":"(-40 – +70) °C"},{"name":"恒定湿热"},{"name":"交变湿热"},{"name":"温度范围","range":"(-40 – +70) °C"},{"name":"wilgotność wzgl.","range":"(10 – 98) %"},{"name":"短时供电跌落"},{"name":"电快速瞬变脉冲群"},{"name":"静电放电"},{"name":"przeciążenie ciśnieniem"},{"name":"振动影响"},{"name":"冲击"},{"name":"przeciążenie ciśnieniem (mechaniczne)"},{"name":"压力范围","range":"(0,4 – 135) bar abs"}]},{"_id":"6a7d75f9441eff5f1564883e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Czujniki platynowe termometru rezystancyjnego E","methodology":"Rezystancja","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja","reference":"PN-EN 12405-1 + p.C.7.2 | PN-EN 60751","norm_bases":["PN-EN 12405-1 + p.C.7.2","PN-EN 60751"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Czujniki platynowe termometru rezystancyjnego E Rezystancja PN-EN 12405-1 + p.C.7.2 | PN-EN 60751 Czujniki platynowe termometru rezystancyjnego E Rezystancja PN-EN 12405-1 + p.C.7.2 | PN-EN 60751","categories":["metrology"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Platinum resistance thermometer sensors E Resistance Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 + p.C.7.2 | PN-EN 60751","test_object_en":"Platinum resistance thermometer sensors E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"电阻 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 + p.C.7.2 | PN-EN 60751","lab_section_zh":"流量计量实验室（GM-1）","methodology_zh":"电阻"},{"_id":"6a7d75f9441eff5f1564883f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Czujniki platynowe termometru rezystancyjnego E","methodology":"Czas odpowiedzi termicznej, Współczynnik samonagrzewania, Głębokość zanurzenia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas odpowiedzi termicznej, Współczynnik samonagrzewania, Głębokość zanurzenia","reference":"PN-EN 12405-1 Załącznik C | PN-EN 60751","norm_bases":["PN-EN 12405-1 Załącznik C","PN-EN 60751"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Czujniki platynowe termometru rezystancyjnego E Czas odpowiedzi termicznej, Współczynnik samonagrzewania, Głębokość zanurzenia PN-EN 12405-1 Załącznik C | PN-EN 60751 Czujniki platynowe termometru rezystancyjnego E Czas odpowiedzi termicznej, Wspolczynnik samonagrzewania, Glebokosc zanurzenia PN-EN 12405-1 Zalacznik C | PN-EN 60751","categories":["metrology"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Thermal response time, Self-heating coefficient, Immersion depth","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Platinum resistance thermometer sensors E Thermal response time, Self-heating coefficient, Immersion depth Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 Załącznik C | PN-EN 60751","test_object_en":"Platinum resistance thermometer sensors E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 Załącznik C | PN-EN 60751","lab_section_zh":"流量计量实验室（GM-1）"},{"_id":"6a7d75f9441eff5f15648840","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki ciśnienia E","methodology":"Odporność na zmiany zasilania elektrycznego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zmiany zasilania elektrycznego","reference":"PN-EN 61000-4-11 | PN-EN 12405-1 p.B4","norm_bases":["PN-EN 61000-4-11","PN-EN 12405-1 p.B4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki ciśnienia E Odporność na zmiany zasilania elektrycznego PN-EN 61000-4-11 | PN-EN 12405-1 p.B4 Przetworniki cisnienia E Odpornosc na zmiany zasilania elektrycznego PN-EN 61000-4-11 | PN-EN 12405-1 p.B4","categories":["other"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Immunity to variations in the electrical power supply","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Pressure transmitters E Immunity to variations in the electrical power supply Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 61000-4-11 | PN-EN 12405-1 p.B4","test_object_en":"Pressure transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"压力变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 61000-4-11 | PN-EN 12405-1 p.B4","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"压力变送器 E"},{"_id":"6a7d75f9441eff5f15648841","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki ciśnienia E","methodology":"Wpływ krótkotrwałych spadków zasilania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ krótkotrwałych spadków zasilania","reference":"PN-EN 61000-4-11 | PN-EN 12405-1 p.B4","norm_bases":["PN-EN 61000-4-11","PN-EN 12405-1 p.B4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki ciśnienia E Wpływ krótkotrwałych spadków zasilania PN-EN 61000-4-11 | PN-EN 12405-1 p.B4 Przetworniki cisnienia E Wplyw krotkotrwalych spadkow zasilania PN-EN 61000-4-11 | PN-EN 12405-1 p.B4","categories":["other"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of short-duration voltage dips","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Pressure transmitters E Effect of short-duration voltage dips Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 61000-4-11 | PN-EN 12405-1 p.B4","test_object_en":"Pressure transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"压力变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 61000-4-11 | PN-EN 12405-1 p.B4","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"压力变送器 E"},{"_id":"6a7d75f9441eff5f15648842","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki ciśnienia E","methodology":"Wpływ serii szybkich elektrycznych stanów przejściowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ serii szybkich elektrycznych stanów przejściowych","reference":"PN-EN 12405-1 p.B4","norm_bases":["PN-EN 12405-1 p.B4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki ciśnienia E Wpływ serii szybkich elektrycznych stanów przejściowych PN-EN 12405-1 p.B4 Przetworniki cisnienia E Wplyw serii szybkich elektrycznych stanow przejsciowych PN-EN 12405-1 p.B4","categories":["other"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of electrical fast transient bursts","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Pressure transmitters E Effect of electrical fast transient bursts Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.B4","test_object_en":"Pressure transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"压力变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.B4","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"压力变送器 E"},{"_id":"6a7d75f9441eff5f15648843","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki ciśnienia E","methodology":"Wpływ wyładowań elektrostatycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ wyładowań elektrostatycznych","reference":"PN-EN 12405-1 p.B4","norm_bases":["PN-EN 12405-1 p.B4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki ciśnienia E Wpływ wyładowań elektrostatycznych PN-EN 12405-1 p.B4 Przetworniki cisnienia E Wplyw wyladowan elektrostatycznych PN-EN 12405-1 p.B4","categories":["other"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of electrostatic discharges","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Pressure transmitters E Effect of electrostatic discharges Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.B4","test_object_en":"Pressure transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"压力变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.B4","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"压力变送器 E"},{"_id":"6a7d75f9441eff5f15648844","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki ciśnienia E","methodology":"Cechy i właściwości konstrukcyjne i użytkowe:","parameters":[{"name":"dokładność"},{"name":"trwałość"},{"name":"działanie alarmów"},{"name":"powtarzalność"},{"name":"odporność na temperaturę otoczenia"},{"name":"Zakres temperatury","range":"(-40 – +70) °C"},{"name":"wilgotne gorąco stałe"},{"name":"wilgotne gorąco cykliczne"},{"name":"Zakres temperatury:","range":"(-40 – +55) °C"},{"name":"Wilgotność wzgl.","range":"(10 – 98) %"},{"name":"krótkotrwałe spadki zasilania"},{"name":"serie szybkich elektrycznych stanów przejściowych"},{"name":"wyładowania elektrostatyczne"},{"name":"przeciążenie ciśnieniem"},{"name":"wpływ wibracji"},{"name":"udary"},{"name":"przeciążenie ciśnieniem (mechaniczne)"},{"name":"Zakres ciśnienia","range":"(0,4 – 135) bar abs"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości konstrukcyjne i użytkowe:\nZakres:\ndokładność\ntrwałość\ndziałanie alarmów\npowtarzalność\nodporność na temperaturę otoczenia\nZakres temperatury (-40 – +70) °C\nwilgotne gorąco stałe\nwilgotne gorąco cykliczne\nZakres temperatury: (-40 – +55) °C\nWilgotność wzgl. (10 – 98) %\nkrótkotrwałe spadki zasilania\nserie szybkich elektrycznych stanów przejściowych\nwyładowania elektrostatyczne\nprzeciążenie ciśnieniem\nwpływ wibracji\nudary\nprzeciążenie ciśnieniem (mechaniczne)\nZakres ciśnienia (0,4 – 135) bar abs","reference":"PN-EN 12405-1","norm_bases":["PN-EN 12405-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki ciśnienia E Cechy i właściwości konstrukcyjne i użytkowe:\nZakres:\ndokładność\ntrwałość\ndziałanie alarmów\npowtarzalność\nodporność na temperaturę otoczenia\nZakres temperatury (-40 – +70) °C\nwilgotne gorąco stałe\nwilgotne gorąco cykliczne\nZakres temperatury: (-40 – +55) °C\nWilgotność wzgl. (10 – 98) %\nkrótkotrwałe spadki zasilania\nserie szybkich elektrycznych stanów przejściowych\nwyładowania elektrostatyczne\nprzeciążenie ciśnieniem\nwpływ wibracji\nudary\nprzeciążenie ciśnieniem (mechaniczne)\nZakres ciśnienia (0,4 – 135) bar abs PN-EN 12405-1 Przetworniki cisnienia E Cechy i wlasciwosci konstrukcyjne i uzytkowe:\nZakres:\ndokladnosc\ntrwalosc\ndzialanie alarmow\npowtarzalnosc\nodpornosc na temperature otoczenia\nZakres temperatury (-40 – +70) °C\nwilgotne goraco stale\nwilgotne goraco cykliczne\nZakres temperatury: (-40 – +55) °C\nWilgotnosc wzgl. (10 – 98) %\nkrotkotrwale spadki zasilania\nserie szybkich elektrycznych stanow przejsciowych\nwyladowania elektrostatyczne\nprzeciazenie cisnieniem\nwplyw wibracji\nudary\nprzeciazenie cisnieniem (mechaniczne)\nZakres cisnienia (0,4 – 135) bar abs PN-EN 12405-1","categories":["other"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Design and performance characteristics and properties:","parameters_en":[{"name":"accuracy"},{"name":"durability"},{"name":"operation of alarms"},{"name":"repeatability"},{"name":"resistance to ambient temperature"},{"name":"Temperature range","range":"(-40 – +70) °C"},{"name":"damp heat steady state"},{"name":"damp heat cyclic"},{"name":"Temperature range:","range":"(-40 – +55) °C"},{"name":"Rel. humidity","range":"(10 – 98) %"},{"name":"short-term supply voltage dips"},{"name":"electrical fast transient/burst"},{"name":"electrostatic discharge"},{"name":"pressure overload"},{"name":"effect of vibration"},{"name":"impacts"},{"name":"pressure overload (mechanical)"},{"name":"Pressure range","range":"(0,4 – 135) bar abs"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Pressure transmitters E Design and performance characteristics and properties: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. accuracy durability operation of alarms repeatability resistance to ambient temperature Temperature range damp heat steady state damp heat cyclic Temperature range: Rel. humidity short-term supply voltage dips electrical fast transient/burst electrostatic discharge pressure overload effect of vibration impacts pressure overload (mechanical) Pressure range PN-EN 12405-1","test_object_en":"Pressure transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"压力变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 准确度 耐久性 报警动作 重复性 温度范围 恒定湿热 交变湿热 相对湿度 短时供电跌落 电快速瞬变脉冲群 静电放电 振动影响 冲击 压力范围 PN-EN 12405-1","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"准确度"},{"name":"耐久性"},{"name":"报警动作"},{"name":"重复性"},{"name":"odporność na temperaturę otoczenia"},{"name":"温度范围","range":"(-40 – +70) °C"},{"name":"恒定湿热"},{"name":"交变湿热"},{"name":"Zakres temperatury:","range":"(-40 – +55) °C"},{"name":"相对湿度","range":"(10 – 98) %"},{"name":"短时供电跌落"},{"name":"电快速瞬变脉冲群"},{"name":"静电放电"},{"name":"przeciążenie ciśnieniem"},{"name":"振动影响"},{"name":"冲击"},{"name":"przeciążenie ciśnieniem (mechaniczne)"},{"name":"压力范围","range":"(0,4 – 135) bar abs"}],"test_object_zh":"压力变送器 E"},{"_id":"6a7d75f9441eff5f15648845","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki temperatury E","methodology":"Odporność na zmiany zasilania elektrycznego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zmiany zasilania elektrycznego","reference":"PN-EN 61000-4-11 | PN-EN 12405-1 p.D4","norm_bases":["PN-EN 61000-4-11","PN-EN 12405-1 p.D4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki temperatury E Odporność na zmiany zasilania elektrycznego PN-EN 61000-4-11 | PN-EN 12405-1 p.D4 Przetworniki temperatury E Odpornosc na zmiany zasilania elektrycznego PN-EN 61000-4-11 | PN-EN 12405-1 p.D4","categories":["other"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Immunity to variations in the electrical power supply","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Temperature transmitters E Immunity to variations in the electrical power supply Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 61000-4-11 | PN-EN 12405-1 p.D4","test_object_en":"Temperature transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 61000-4-11 | PN-EN 12405-1 p.D4","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"温度变送器 E"},{"_id":"6a7d75f9441eff5f15648846","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki temperatury E","methodology":"Wpływ krótkotrwałych spadków zasilania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ krótkotrwałych spadków zasilania","reference":"PN-EN 61000-4-11 | PN-EN 12405-1 p.D4","norm_bases":["PN-EN 61000-4-11","PN-EN 12405-1 p.D4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki temperatury E Wpływ krótkotrwałych spadków zasilania PN-EN 61000-4-11 | PN-EN 12405-1 p.D4 Przetworniki temperatury E Wplyw krotkotrwalych spadkow zasilania PN-EN 61000-4-11 | PN-EN 12405-1 p.D4","categories":["other"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of short-duration voltage dips","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Temperature transmitters E Effect of short-duration voltage dips Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 61000-4-11 | PN-EN 12405-1 p.D4","test_object_en":"Temperature transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 61000-4-11 | PN-EN 12405-1 p.D4","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"温度变送器 E"},{"_id":"6a7d75f9441eff5f15648847","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki temperatury E","methodology":"Wpływ serii szybkich elektrycznych stanów przejściowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ serii szybkich elektrycznych stanów przejściowych","reference":"PN-EN 12405-1 p.D4","norm_bases":["PN-EN 12405-1 p.D4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki temperatury E Wpływ serii szybkich elektrycznych stanów przejściowych PN-EN 12405-1 p.D4 Przetworniki temperatury E Wplyw serii szybkich elektrycznych stanow przejsciowych PN-EN 12405-1 p.D4","categories":["other"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of electrical fast transient bursts","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Temperature transmitters E Effect of electrical fast transient bursts Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.D4","test_object_en":"Temperature transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.D4","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"温度变送器 E"},{"_id":"6a7d75f9441eff5f15648848","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki temperatury E","methodology":"Wpływ wyładowań elektrostatycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wpływ wyładowań elektrostatycznych","reference":"PN-EN 12405-1 p.D4","norm_bases":["PN-EN 12405-1 p.D4"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki temperatury E Wpływ wyładowań elektrostatycznych PN-EN 12405-1 p.D4 Przetworniki temperatury E Wplyw wyladowan elektrostatycznych PN-EN 12405-1 p.D4","categories":["other"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Effect of electrostatic discharges","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Temperature transmitters E Effect of electrostatic discharges Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12405-1 p.D4","test_object_en":"Temperature transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12405-1 p.D4","lab_section_zh":"流量计量实验室（GM-1）","test_object_zh":"温度变送器 E"},{"_id":"6a7d75f9441eff5f15648849","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Przetworniki temperatury E","methodology":"Właściwości konstrukcyjne i cechy użytkowe:","parameters":[{"name":"dokładność"},{"name":"odporność na temperaturę otoczenia"},{"name":"Zakres temperatury","range":"(-40 – +70) °C"},{"name":"wilgotne gorąco stałe"},{"name":"wilgotne gorąco cykliczne"},{"name":"Zakres temperatury","range":"(-40 – +55) °C,"},{"name":"Wilgotność wzgl.","range":"(10 – 98) %"},{"name":"krótkotrwałe spadki zasilania"},{"name":"serie szybkich elektrycznych stanów przejściowych"},{"name":"wyładowania elektrostatyczne"},{"name":"wpływ wibracji"},{"name":"udary"},{"name":"trwałość"},{"name":"działanie alarmów"},{"name":"powtarzalność"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości konstrukcyjne i cechy użytkowe:\nZakres:\ndokładność\nodporność na temperaturę otoczenia\nZakres temperatury (-40 – +70) °C\nwilgotne gorąco stałe\nwilgotne gorąco cykliczne\nZakres temperatury (-40 – +55) °C,\nWilgotność wzgl. (10 – 98) %\nkrótkotrwałe spadki zasilania\nserie szybkich elektrycznych stanów przejściowych\nwyładowania elektrostatyczne\nwpływ wibracji\nudary\ntrwałość\ndziałanie alarmów\npowtarzalność","reference":"PN-EN 12405-1","norm_bases":["PN-EN 12405-1"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przetworniki temperatury E Właściwości konstrukcyjne i cechy użytkowe:\nZakres:\ndokładność\nodporność na temperaturę otoczenia\nZakres temperatury (-40 – +70) °C\nwilgotne gorąco stałe\nwilgotne gorąco cykliczne\nZakres temperatury (-40 – +55) °C,\nWilgotność wzgl. (10 – 98) %\nkrótkotrwałe spadki zasilania\nserie szybkich elektrycznych stanów przejściowych\nwyładowania elektrostatyczne\nwpływ wibracji\nudary\ntrwałość\ndziałanie alarmów\npowtarzalność PN-EN 12405-1 Przetworniki temperatury E Wlasciwosci konstrukcyjne i cechy uzytkowe:\nZakres:\ndokladnosc\nodpornosc na temperature otoczenia\nZakres temperatury (-40 – +70) °C\nwilgotne goraco stale\nwilgotne goraco cykliczne\nZakres temperatury (-40 – +55) °C,\nWilgotnosc wzgl. (10 – 98) %\nkrotkotrwale spadki zasilania\nserie szybkich elektrycznych stanow przejsciowych\nwyladowania elektrostatyczne\nwplyw wibracji\nudary\ntrwalosc\ndzialanie alarmow\npowtarzalnosc PN-EN 12405-1","categories":["other"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Design properties and performance characteristics:","parameters_en":[{"name":"accuracy"},{"name":"resistance to ambient temperature"},{"name":"Temperature range","range":"(-40 – +70) °C"},{"name":"damp heat steady state"},{"name":"damp heat cyclic"},{"name":"Temperature range","range":"(-40 – +55) °C,"},{"name":"Rel. humidity","range":"(10 – 98) %"},{"name":"short-term supply voltage dips"},{"name":"electrical fast transient/burst"},{"name":"electrostatic discharge"},{"name":"effect of vibration"},{"name":"impacts"},{"name":"durability"},{"name":"operation of alarms"},{"name":"repeatability"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Temperature transmitters E Design properties and performance characteristics: Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. accuracy resistance to ambient temperature Temperature range damp heat steady state damp heat cyclic Temperature range Rel. humidity short-term supply voltage dips electrical fast transient/burst electrostatic discharge effect of vibration impacts durability operation of alarms repeatability PN-EN 12405-1","test_object_en":"Temperature transmitters E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"温度变送器 E 流量计量实验室（GM-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 准确度 温度范围 恒定湿热 交变湿热 温度范围 相对湿度 短时供电跌落 电快速瞬变脉冲群 静电放电 振动影响 冲击 耐久性 报警动作 重复性 PN-EN 12405-1","lab_section_zh":"流量计量实验室（GM-1）","parameters_zh":[{"name":"准确度"},{"name":"odporność na temperaturę otoczenia"},{"name":"温度范围","range":"(-40 – +70) °C"},{"name":"恒定湿热"},{"name":"交变湿热"},{"name":"温度范围","range":"(-40 – +55) °C,"},{"name":"相对湿度","range":"(10 – 98) %"},{"name":"短时供电跌落"},{"name":"电快速瞬变脉冲群"},{"name":"静电放电"},{"name":"振动影响"},{"name":"冲击"},{"name":"耐久性"},{"name":"报警动作"},{"name":"重复性"}],"test_object_zh":"温度变送器 E"},{"_id":"6a7d75f9441eff5f1564884a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków E","methodology":"Odporność na wysoką temperaturę otoczenia","parameters":[{"name":"Zakres strumienia objętości przecieku w warunkach normalnych: (0,014 – 0,9) m3/h"},{"name":"Temperatura maksymalna","range":"650 °C"},{"name":"Maksymalne wymiary obiektu:","range":"(520x450x650) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wysoką temperaturę otoczenia\nZakres:\nZakres strumienia objętości przecieku w warunkach normalnych: (0,014 – 0,9) m3/h\nTemperatura maksymalna 650 °C\nMaksymalne wymiary obiektu: (520x450x650) mm","reference":"PN-EN 1775 Procedura B „N”","norm_bases":["PN-EN 1775 Procedura B „N”"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków E Odporność na wysoką temperaturę otoczenia\nZakres:\nZakres strumienia objętości przecieku w warunkach normalnych: (0,014 – 0,9) m3/h\nTemperatura maksymalna 650 °C\nMaksymalne wymiary obiektu: (520x450x650) mm PN-EN 1775 Procedura B „N” Kurki kulowe do instalacji gazowych budynkow E Odpornosc na wysoka temperature otoczenia\nZakres:\nZakres strumienia objetosci przecieku w warunkach normalnych: (0,014 – 0,9) m3/h\nTemperatura maksymalna 650 °C\nMaksymalne wymiary obiektu: (520x450x650) mm PN-EN 1775 Procedura B „N”","categories":["other"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Resistance to high ambient temperature","parameters_en":[{"name":"Range of the leakage volume flow rate under normal conditions: (0,014 – 0,9) m3/h"},{"name":"Maximum temperature","range":"650 °C"},{"name":"Maximum dimensions of the object:","range":"(520x450x650) mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Ball valves for gas installations in buildings E Resistance to high ambient temperature Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range of the leakage volume flow rate under normal conditions: (0,014 – 0,9) m3/h Maximum temperature Maximum dimensions of the object: PN-EN 1775 Procedura B „N”","test_object_en":"Ball valves for gas installations in buildings E","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"流量计量实验室（GM-1） 最高温度 对象最大尺寸： PN-EN 1775 Procedura B „N”","parameters_zh":[{"name":"Zakres strumienia objętości przecieku w warunkach normalnych: (0,014 – 0,9) m3/h"},{"name":"最高温度","range":"650 °C"},{"name":"对象最大尺寸：","range":"(520x450x650) mm"}]},{"_id":"6a7d75f9441eff5f1564884b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków E","methodology":"Wymiary gwintów przyłączeniowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary gwintów przyłączeniowych","reference":"PN-EN 10226-1 „N” | PN-EN ISO 228-1 „N”","norm_bases":["PN-EN 10226-1 „N”","PN-EN ISO 228-1 „N”"],"lab_section":"Laboratorium Metrologii Przepływów (GM-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków E Wymiary gwintów przyłączeniowych PN-EN 10226-1 „N” | PN-EN ISO 228-1 „N” Kurki kulowe do instalacji gazowych budynkow E Wymiary gwintow przylaczeniowych PN-EN 10226-1 „N” | PN-EN ISO 228-1 „N”","categories":["other"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Flow Metrology Laboratory (GM-1)","methodology_en":"Dimensions of connection threads","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Ball valves for gas installations in buildings E Dimensions of connection threads Flow Metrology Laboratory (GM-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 10226-1 „N” | PN-EN ISO 228-1 „N”","test_object_en":"Ball valves for gas installations in buildings E","lab_section_zh":"流量计量实验室（GM-1）","search_zh":"流量计量实验室（GM-1） PN-EN 10226-1 „N” | PN-EN ISO 228-1 „N”"},{"_id":"6a7d75f9441eff5f1564884c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków","methodology":"Szczelność w zadeklarowanych przez producenta klasach temperaturowych","parameters":[{"name":"Zakres","range":"do 20 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 20 bar","reference":"PN-EN 331:2005P p.7.2 | PN-EN 331:2005/A1:2011E p.7.2","norm_bases":["PN-EN 331:2005P p.7.2","PN-EN 331:2005/A1:2011E p.7.2"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków Szczelność w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 20 bar PN-EN 331:2005P p.7.2 | PN-EN 331:2005/A1:2011E p.7.2 Kurki kulowe do instalacji gazowych budynkow Szczelnosc w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 20 bar PN-EN 331:2005P p.7.2 | PN-EN 331:2005/A1:2011E p.7.2","categories":["other"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Tightness in the temperature classes declared by the manufacturer","parameters_en":[{"name":"Range","range":"do 20 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ball valves for gas installations in buildings Tightness in the temperature classes declared by the manufacturer Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 331:2005P p.7.2 | PN-EN 331:2005/A1:2011E p.7.2","test_object_en":"Ball valves for gas installations in buildings","parameters_zh":[{"name":"范围","range":"do 20 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"建筑燃气装置用球阀 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 331:2005P p.7.2 | PN-EN 331:2005/A1:2011E p.7.2","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"建筑燃气装置用球阀"},{"_id":"6a7d75f9441eff5f1564884d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków","methodology":"Moment napędowy","parameters":[{"name":"Zakres","range":"do 40 Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Moment napędowy\nZakres do 40 Nm","reference":"PN-EN 331:2005P p.7.4 | PN-EN 331:2005/A1:2011E p.7.4","norm_bases":["PN-EN 331:2005P p.7.4","PN-EN 331:2005/A1:2011E p.7.4"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków Moment napędowy\nZakres do 40 Nm PN-EN 331:2005P p.7.4 | PN-EN 331:2005/A1:2011E p.7.4 Kurki kulowe do instalacji gazowych budynkow Moment napedowy\nZakres do 40 Nm PN-EN 331:2005P p.7.4 | PN-EN 331:2005/A1:2011E p.7.4","categories":["other"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Driving torque","parameters_en":[{"name":"Range","range":"do 40 Nm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ball valves for gas installations in buildings Driving torque Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 331:2005P p.7.4 | PN-EN 331:2005/A1:2011E p.7.4","test_object_en":"Ball valves for gas installations in buildings","parameters_zh":[{"name":"范围","range":"do 40 Nm"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"建筑燃气装置用球阀 驱动力矩 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 331:2005P p.7.4 | PN-EN 331:2005/A1:2011E p.7.4","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"建筑燃气装置用球阀","methodology_zh":"驱动力矩"},{"_id":"6a7d75f9441eff5f1564884e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków","methodology":"Trwałość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość","reference":"PN-EN 331:2005P p.7.6 | PN-EN 331:2005/A1:2011E p.7.6","norm_bases":["PN-EN 331:2005P p.7.6","PN-EN 331:2005/A1:2011E p.7.6"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków Trwałość PN-EN 331:2005P p.7.6 | PN-EN 331:2005/A1:2011E p.7.6 Kurki kulowe do instalacji gazowych budynkow Trwalosc PN-EN 331:2005P p.7.6 | PN-EN 331:2005/A1:2011E p.7.6","categories":["other"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Durability","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ball valves for gas installations in buildings Durability Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 331:2005P p.7.6 | PN-EN 331:2005/A1:2011E p.7.6","test_object_en":"Ball valves for gas installations in buildings","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"建筑燃气装置用球阀 耐久性 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 331:2005P p.7.6 | PN-EN 331:2005/A1:2011E p.7.6","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","methodology_zh":"耐久性","test_object_zh":"建筑燃气装置用球阀"},{"_id":"6a7d75f9441eff5f1564884f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków","methodology":"Wytrzymałość na zginanie i skręcanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie i skręcanie","reference":"PN-EN 331:2005P p.7.5 | PN-EN 331:2005/A1:2011E p.7.5","norm_bases":["PN-EN 331:2005P p.7.5","PN-EN 331:2005/A1:2011E p.7.5"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków Wytrzymałość na zginanie i skręcanie PN-EN 331:2005P p.7.5 | PN-EN 331:2005/A1:2011E p.7.5 Kurki kulowe do instalacji gazowych budynkow Wytrzymalosc na zginanie i skrecanie PN-EN 331:2005P p.7.5 | PN-EN 331:2005/A1:2011E p.7.5","categories":["other"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Flexural and torsional strength","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ball valves for gas installations in buildings Flexural and torsional strength Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 331:2005P p.7.5 | PN-EN 331:2005/A1:2011E p.7.5","test_object_en":"Ball valves for gas installations in buildings","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"建筑燃气装置用球阀 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 331:2005P p.7.5 | PN-EN 331:2005/A1:2011E p.7.5","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"建筑燃气装置用球阀"},{"_id":"6a7d75f9441eff5f15648850","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków","methodology":"Strumień nominalny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Strumień nominalny","reference":"PN-EN 331:2005P p.7.3 | PN-EN 331:2005/A1:2011E p.7.3","norm_bases":["PN-EN 331:2005P p.7.3","PN-EN 331:2005/A1:2011E p.7.3"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków Strumień nominalny PN-EN 331:2005P p.7.3 | PN-EN 331:2005/A1:2011E p.7.3 Kurki kulowe do instalacji gazowych budynkow Strumien nominalny PN-EN 331:2005P p.7.3 | PN-EN 331:2005/A1:2011E p.7.3","categories":["other"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Nominal flux","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ball valves for gas installations in buildings Nominal flux Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 331:2005P p.7.3 | PN-EN 331:2005/A1:2011E p.7.3","test_object_en":"Ball valves for gas installations in buildings","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"建筑燃气装置用球阀 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 331:2005P p.7.3 | PN-EN 331:2005/A1:2011E p.7.3","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"建筑燃气装置用球阀"},{"_id":"6a7d75f9441eff5f15648851","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków","methodology":"Kąt uszczelnienia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kąt uszczelnienia","reference":"PN-EN 331:2005P p.7.7 | PN-EN 331:2005/A1:2011E p.7.7","norm_bases":["PN-EN 331:2005P p.7.7","PN-EN 331:2005/A1:2011E p.7.7"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków Kąt uszczelnienia PN-EN 331:2005P p.7.7 | PN-EN 331:2005/A1:2011E p.7.7 Kurki kulowe do instalacji gazowych budynkow Kat uszczelnienia PN-EN 331:2005P p.7.7 | PN-EN 331:2005/A1:2011E p.7.7","categories":["other"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Sealing angle","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ball valves for gas installations in buildings Sealing angle Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 331:2005P p.7.7 | PN-EN 331:2005/A1:2011E p.7.7","test_object_en":"Ball valves for gas installations in buildings","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"建筑燃气装置用球阀 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 331:2005P p.7.7 | PN-EN 331:2005/A1:2011E p.7.7","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"建筑燃气装置用球阀"},{"_id":"6a7d75f9441eff5f15648852","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków","methodology":"Odporność na wilgotność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wilgotność","reference":"PN-EN 331:2005P p.7.6.5 | PN-EN 331:2005/A1:2011E p.7.6.5","norm_bases":["PN-EN 331:2005P p.7.6.5","PN-EN 331:2005/A1:2011E p.7.6.5"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków Odporność na wilgotność PN-EN 331:2005P p.7.6.5 | PN-EN 331:2005/A1:2011E p.7.6.5 Kurki kulowe do instalacji gazowych budynkow Odpornosc na wilgotnosc PN-EN 331:2005P p.7.6.5 | PN-EN 331:2005/A1:2011E p.7.6.5","categories":["other"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Humidity resistance","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ball valves for gas installations in buildings Humidity resistance Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 331:2005P p.7.6.5 | PN-EN 331:2005/A1:2011E p.7.6.5","test_object_en":"Ball valves for gas installations in buildings","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"建筑燃气装置用球阀 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 331:2005P p.7.6.5 | PN-EN 331:2005/A1:2011E p.7.6.5","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"建筑燃气装置用球阀"},{"_id":"6a7d75f9441eff5f15648853","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki kulowe do instalacji gazowych budynków","methodology":"Wytrzymałość ograniczników","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość ograniczników","reference":"PN-EN 331:2005P p.7.8 | PN-EN 331:2005/A1:2011E p.7.8","norm_bases":["PN-EN 331:2005P p.7.8","PN-EN 331:2005/A1:2011E p.7.8"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kurki kulowe do instalacji gazowych budynków Wytrzymałość ograniczników PN-EN 331:2005P p.7.8 | PN-EN 331:2005/A1:2011E p.7.8 Kurki kulowe do instalacji gazowych budynkow Wytrzymalosc ogranicznikow PN-EN 331:2005P p.7.8 | PN-EN 331:2005/A1:2011E p.7.8","categories":["other"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Strength of stops","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ball valves for gas installations in buildings Strength of stops Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 331:2005P p.7.8 | PN-EN 331:2005/A1:2011E p.7.8","test_object_en":"Ball valves for gas installations in buildings","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"建筑燃气装置用球阀 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 331:2005P p.7.8 | PN-EN 331:2005/A1:2011E p.7.8","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"建筑燃气装置用球阀"},{"_id":"6a7d75f9441eff5f15648854","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej","methodology":"Masowy (MFR) wskaźnik szybkości płynięcia tworzywa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Masowy (MFR) wskaźnik szybkości płynięcia tworzywa","reference":"PN-EN ISO 1133:2006","norm_bases":["PN-EN ISO 1133:2006"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej Masowy (MFR) wskaźnik szybkości płynięcia tworzywa PN-EN ISO 1133:2006 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej Masowy (MFR) wskaznik szybkosci plyniecia tworzywa PN-EN ISO 1133:2006","categories":["materials"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Mass (MFR) melt flow rate of the plastic","search_en":"Protective plastics coatings on steel pipes and fittings Mass (MFR) melt flow rate of the plastic Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) PN-EN ISO 1133:2006","test_object_en":"Protective plastics coatings on steel pipes and fittings","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","search_zh":"燃气管道阀门与运行技术检测实验室（GP-1） PN-EN ISO 1133:2006"},{"_id":"6a7d75f9441eff5f15648855","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura odcinająca do sieci gazowych i wodociągowych E","methodology":"Moment napędowy","parameters":[{"name":"Zakres","range":"do 800 Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Moment napędowy\nZakres do 800 Nm","reference":"PN-EN 13774 p.5.5","norm_bases":["PN-EN 13774 p.5.5"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura odcinająca do sieci gazowych i wodociągowych E Moment napędowy\nZakres do 800 Nm PN-EN 13774 p.5.5 Armatura odcinajaca do sieci gazowych i wodociagowych E Moment napedowy\nZakres do 800 Nm PN-EN 13774 p.5.5","categories":["water"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Driving torque","parameters_en":[{"name":"Range","range":"do 800 Nm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Shut-off valves for gas and water supply networks E Driving torque Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 13774 p.5.5","test_object_en":"Shut-off valves for gas and water supply networks E","parameters_zh":[{"name":"范围","range":"do 800 Nm"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气与给水管网用截断阀 E 驱动力矩 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 13774 p.5.5","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"燃气与给水管网用截断阀 E","methodology_zh":"驱动力矩"},{"_id":"6a7d75f9441eff5f15648856","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura odcinająca do sieci gazowych i wodociągowych E","methodology":"Wytrzymałość","parameters":[{"name":"Zakres","range":"do 150 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość\nZakres do 150 bar","reference":"PN-EN 12266-1A2 | PN-EN 1074-1 p.5.1","norm_bases":["PN-EN 12266-1A2","PN-EN 1074-1 p.5.1"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura odcinająca do sieci gazowych i wodociągowych E Wytrzymałość\nZakres do 150 bar PN-EN 12266-1A2 | PN-EN 1074-1 p.5.1 Armatura odcinajaca do sieci gazowych i wodociagowych E Wytrzymalosc\nZakres do 150 bar PN-EN 12266-1A2 | PN-EN 1074-1 p.5.1","categories":["water"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Strength","parameters_en":[{"name":"Range","range":"do 150 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Shut-off valves for gas and water supply networks E Strength Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 12266-1A2 | PN-EN 1074-1 p.5.1","test_object_en":"Shut-off valves for gas and water supply networks E","parameters_zh":[{"name":"范围","range":"do 150 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气与给水管网用截断阀 E 强度 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12266-1A2 | PN-EN 1074-1 p.5.1","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","methodology_zh":"强度","test_object_zh":"燃气与给水管网用截断阀 E"},{"_id":"6a7d75f9441eff5f15648857","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura odcinająca do sieci gazowych i wodociągowych E","methodology":"Szczelność zewnętrzna","parameters":[{"name":"Zakres","range":"do 120 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność zewnętrzna\nZakres do 120 bar","reference":"PN-EN 12266-1, A.3 | PN-EN 1074-1 p.5.2","norm_bases":["PN-EN 12266-1, A.3","PN-EN 1074-1 p.5.2"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura odcinająca do sieci gazowych i wodociągowych E Szczelność zewnętrzna\nZakres do 120 bar PN-EN 12266-1, A.3 | PN-EN 1074-1 p.5.2 Armatura odcinajaca do sieci gazowych i wodociagowych E Szczelnosc zewnetrzna\nZakres do 120 bar PN-EN 12266-1, A.3 | PN-EN 1074-1 p.5.2","categories":["water"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"External tightness","parameters_en":[{"name":"Range","range":"do 120 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Shut-off valves for gas and water supply networks E External tightness Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 12266-1, A.3 | PN-EN 1074-1 p.5.2","test_object_en":"Shut-off valves for gas and water supply networks E","parameters_zh":[{"name":"范围","range":"do 120 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气与给水管网用截断阀 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12266-1, A.3 | PN-EN 1074-1 p.5.2","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"燃气与给水管网用截断阀 E"},{"_id":"6a7d75f9441eff5f15648858","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura odcinająca do sieci gazowych i wodociągowych E","methodology":"Szczelność zamknięcia","parameters":[{"name":"Zakres","range":"do 6 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność zamknięcia\nZakres do 6 bar","reference":"PN-EN 12266-1, A.4 | PN-EN 1074-1 p.5.2","norm_bases":["PN-EN 12266-1, A.4","PN-EN 1074-1 p.5.2"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura odcinająca do sieci gazowych i wodociągowych E Szczelność zamknięcia\nZakres do 6 bar PN-EN 12266-1, A.4 | PN-EN 1074-1 p.5.2 Armatura odcinajaca do sieci gazowych i wodociagowych E Szczelnosc zamkniecia\nZakres do 6 bar PN-EN 12266-1, A.4 | PN-EN 1074-1 p.5.2","categories":["water"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Tightness of the closing","parameters_en":[{"name":"Range","range":"do 6 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Shut-off valves for gas and water supply networks E Tightness of the closing Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 12266-1, A.4 | PN-EN 1074-1 p.5.2","test_object_en":"Shut-off valves for gas and water supply networks E","parameters_zh":[{"name":"范围","range":"do 6 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气与给水管网用截断阀 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12266-1, A.4 | PN-EN 1074-1 p.5.2","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"燃气与给水管网用截断阀 E"},{"_id":"6a7d75f9441eff5f15648859","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura odcinająca do sieci gazowych i wodociągowych E","methodology":"Trwałość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość","reference":"PN-EN 13774 p.5.5 | PN-EN 1074-1 p.5.5","norm_bases":["PN-EN 13774 p.5.5","PN-EN 1074-1 p.5.5"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura odcinająca do sieci gazowych i wodociągowych E Trwałość PN-EN 13774 p.5.5 | PN-EN 1074-1 p.5.5 Armatura odcinajaca do sieci gazowych i wodociagowych E Trwalosc PN-EN 13774 p.5.5 | PN-EN 1074-1 p.5.5","categories":["water"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Durability","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Shut-off valves for gas and water supply networks E Durability Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 13774 p.5.5 | PN-EN 1074-1 p.5.5","test_object_en":"Shut-off valves for gas and water supply networks E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气与给水管网用截断阀 E 耐久性 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 13774 p.5.5 | PN-EN 1074-1 p.5.5","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","methodology_zh":"耐久性","test_object_zh":"燃气与给水管网用截断阀 E"},{"_id":"6a7d75f9441eff5f1564885a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Wytrzymałość hydrauliczna w zadeklarowanych przez producenta klasach temperaturowych","parameters":[{"name":"Zakres","range":"do 60 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość hydrauliczna w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 60 bar","reference":"PN-EN 13828 | PN-M-75002","norm_bases":["PN-EN 13828","PN-M-75002"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Wytrzymałość hydrauliczna w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 60 bar PN-EN 13828 | PN-M-75002 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Wytrzymalosc hydrauliczna w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 60 bar PN-EN 13828 | PN-M-75002","categories":["water"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Hydraulic strength in the temperature classes declared by the manufacturer","parameters_en":[{"name":"Range","range":"do 60 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E Hydraulic strength in the temperature classes declared by the manufacturer Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 13828 | PN-M-75002","test_object_en":"Fittings for water supply, central heating and solar installations E","parameters_zh":[{"name":"范围","range":"do 60 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 13828 | PN-M-75002","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E"},{"_id":"6a7d75f9441eff5f1564885b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Szczelność w zadeklarowanych przez producenta klasach temperaturowych","parameters":[{"name":"Zakres","range":"do 60 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 60 bar","reference":"PN-EN 13828 p.7.4.1 | PN-M-75002 p 6.2.5","norm_bases":["PN-EN 13828 p.7.4.1","PN-M-75002 p 6.2.5"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Szczelność w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 60 bar PN-EN 13828 p.7.4.1 | PN-M-75002 p 6.2.5 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Szczelnosc w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 60 bar PN-EN 13828 p.7.4.1 | PN-M-75002 p 6.2.5","categories":["water"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Tightness in the temperature classes declared by the manufacturer","parameters_en":[{"name":"Range","range":"do 60 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E Tightness in the temperature classes declared by the manufacturer Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 13828 p.7.4.1 | PN-M-75002 p 6.2.5","test_object_en":"Fittings for water supply, central heating and solar installations E","parameters_zh":[{"name":"范围","range":"do 60 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 13828 p.7.4.1 | PN-M-75002 p 6.2.5","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E"},{"_id":"6a7d75f9441eff5f1564885c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Moment napędowy","parameters":[{"name":"Zakres","range":"do 65 Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Moment napędowy\nZakres do 65 Nm","reference":"PN-EN 13828 p.7.1","norm_bases":["PN-EN 13828 p.7.1"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Moment napędowy\nZakres do 65 Nm PN-EN 13828 p.7.1 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Moment napedowy\nZakres do 65 Nm PN-EN 13828 p.7.1","categories":["water"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Driving torque","parameters_en":[{"name":"Range","range":"do 65 Nm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E Driving torque Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 13828 p.7.1","test_object_en":"Fittings for water supply, central heating and solar installations E","parameters_zh":[{"name":"范围","range":"do 65 Nm"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 驱动力矩 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 13828 p.7.1","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E","methodology_zh":"驱动力矩"},{"_id":"6a7d75f9441eff5f1564885d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Trwałość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość","reference":"PN-EN 13828 | PN-EN 1213","norm_bases":["PN-EN 13828","PN-EN 1213"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Trwałość PN-EN 13828 | PN-EN 1213 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Trwalosc PN-EN 13828 | PN-EN 1213","categories":["water"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Durability","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E Durability Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 13828 | PN-EN 1213","test_object_en":"Fittings for water supply, central heating and solar installations E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 耐久性 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 13828 | PN-EN 1213","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","methodology_zh":"耐久性","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E"},{"_id":"6a7d75f9441eff5f1564885e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Sprawdzenie znakowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sprawdzenie znakowania","reference":"PN-M-75002","norm_bases":["PN-M-75002"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Sprawdzenie znakowania PN-M-75002 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Sprawdzenie znakowania PN-M-75002","categories":["water"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Verification of marking","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E Verification of marking Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-M-75002","test_object_en":"Fittings for water supply, central heating and solar installations E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-M-75002","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E"},{"_id":"6a7d75f9441eff5f1564885f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Wygląd zewnętrzny, konstrukcja, montaż i demontaż (rozmiar gwintu – metoda sprawdzianów)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wygląd zewnętrzny, konstrukcja, montaż i demontaż (rozmiar gwintu – metoda sprawdzianów)","reference":"PN-M-75002","norm_bases":["PN-M-75002"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Wygląd zewnętrzny, konstrukcja, montaż i demontaż (rozmiar gwintu – metoda sprawdzianów) PN-M-75002 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Wyglad zewnetrzny, konstrukcja, montaz i demontaz (rozmiar gwintu – metoda sprawdzianow) PN-M-75002","categories":["water","metrology"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"External appearance, construction, assembly and disassembly (thread size – gauge method)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E External appearance, construction, assembly and disassembly (thread size – gauge method) Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-M-75002","test_object_en":"Fittings for water supply, central heating and solar installations E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-M-75002","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E"},{"_id":"6a7d75f9441eff5f15648860","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Działanie (moment napędowy)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Działanie (moment napędowy)","reference":"PN-M-75002","norm_bases":["PN-M-75002"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Działanie (moment napędowy) PN-M-75002 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Dzialanie (moment napedowy) PN-M-75002","categories":["water"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Operation (driving torque)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E Operation (driving torque) Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-M-75002","test_object_en":"Fittings for water supply, central heating and solar installations E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-M-75002","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E"},{"_id":"6a7d75f9441eff5f15648861","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Przepustowość armatury (do DN50)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepustowość armatury (do DN50)","reference":"PN-M-75002","norm_bases":["PN-M-75002"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Przepustowość armatury (do DN50) PN-M-75002 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Przepustowosc armatury (do DN50) PN-M-75002","categories":["water"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Flow capacity of fittings (up to DN50)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E Flow capacity of fittings (up to DN50) Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-M-75002","test_object_en":"Fittings for water supply, central heating and solar installations E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-M-75002","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E"},{"_id":"6a7d75f9441eff5f15648862","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Wytrzymałość na skręcanie (Zakres do 1000 Nm)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na skręcanie (Zakres do 1000 Nm)","reference":"PN-EN 1213 | PN-EN 13828","norm_bases":["PN-EN 1213","PN-EN 13828"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Wytrzymałość na skręcanie (Zakres do 1000 Nm) PN-EN 1213 | PN-EN 13828 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Wytrzymalosc na skrecanie (Zakres do 1000 Nm) PN-EN 1213 | PN-EN 13828","categories":["water"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Torsional strength (Range up to 1000 Nm)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E Torsional strength (Range up to 1000 Nm) Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1213 | PN-EN 13828","test_object_en":"Fittings for water supply, central heating and solar installations E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1213 | PN-EN 13828","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E"},{"_id":"6a7d75f9441eff5f15648863","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E","methodology":"Wytrzymałość na zginanie (Zakres do 5 kN)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie (Zakres do 5 kN)","reference":"PN-EN 1213 | PN-EN 13828","norm_bases":["PN-EN 1213","PN-EN 13828"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji wodociągowych, centralnego ogrzewania i solarnych E Wytrzymałość na zginanie (Zakres do 5 kN) PN-EN 1213 | PN-EN 13828 Armatura do instalacji wodociagowych, centralnego ogrzewania i solarnych E Wytrzymalosc na zginanie (Zakres do 5 kN) PN-EN 1213 | PN-EN 13828","categories":["water"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Flexural strength (Range up to 5 kN)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for water supply, central heating and solar installations E Flexural strength (Range up to 5 kN) Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1213 | PN-EN 13828","test_object_en":"Fittings for water supply, central heating and solar installations E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"给水、中央供暖与太阳能装置用阀门与配件 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1213 | PN-EN 13828","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"给水、中央供暖与太阳能装置用阀门与配件 E"},{"_id":"6a7d75f9441eff5f15648864","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji gazowych E","methodology":"Szczelność zewnętrzna w zadeklarowanych przez producenta klasach temperaturowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność zewnętrzna w zadeklarowanych przez producenta klasach temperaturowych","reference":"PN-EN 12266-1, załącznik A3","norm_bases":["PN-EN 12266-1, załącznik A3"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji gazowych E Szczelność zewnętrzna w zadeklarowanych przez producenta klasach temperaturowych PN-EN 12266-1, załącznik A3 Armatura do instalacji gazowych E Szczelnosc zewnetrzna w zadeklarowanych przez producenta klasach temperaturowych PN-EN 12266-1, zalacznik A3","categories":["other"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"External tightness in the temperature classes declared by the manufacturer","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for gas installations E External tightness in the temperature classes declared by the manufacturer Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12266-1, załącznik A3","test_object_en":"Fittings for gas installations E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12266-1, załącznik A3","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）"},{"_id":"6a7d75f9441eff5f15648865","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura do instalacji gazowych E","methodology":"Wytrzymałość w zadeklarowanych przez producenta klasach temperaturowych","parameters":[{"name":"Zakres","range":"do 8 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 8 bar","reference":"PN-EN 12266-1, załącznik A2","norm_bases":["PN-EN 12266-1, załącznik A2"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura do instalacji gazowych E Wytrzymałość w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 8 bar PN-EN 12266-1, załącznik A2 Armatura do instalacji gazowych E Wytrzymalosc w zadeklarowanych przez producenta klasach temperaturowych\nZakres do 8 bar PN-EN 12266-1, zalacznik A2","categories":["other"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Strength in the temperature classes declared by the manufacturer","parameters_en":[{"name":"Range","range":"do 8 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fittings for gas installations E Strength in the temperature classes declared by the manufacturer Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 12266-1, załącznik A2","test_object_en":"Fittings for gas installations E","parameters_zh":[{"name":"范围","range":"do 8 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12266-1, załącznik A2","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）"},{"_id":"6a7d75f9441eff5f15648866","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura sanitarna, Baterie mechaniczne E","methodology":"Wytrzymałość na ciśnienie wewnętrzne","parameters":[{"name":"Zakres","range":"do 25 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ciśnienie wewnętrzne\nZakres do 25 bar","reference":"PN-EN 817","norm_bases":["PN-EN 817"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura sanitarna, Baterie mechaniczne E Wytrzymałość na ciśnienie wewnętrzne\nZakres do 25 bar PN-EN 817 Armatura sanitarna, Baterie mechaniczne E Wytrzymalosc na cisnienie wewnetrzne\nZakres do 25 bar PN-EN 817","categories":["other"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Resistance to internal pressure","parameters_en":[{"name":"Range","range":"do 25 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Sanitary tapware, Mechanical mixing valves E Resistance to internal pressure Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 817","test_object_en":"Sanitary tapware, Mechanical mixing valves E","parameters_zh":[{"name":"范围","range":"do 25 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"卫生洁具配件、机械式龙头 E 内压强度 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 817","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"卫生洁具配件、机械式龙头 E","methodology_zh":"内压强度"},{"_id":"6a7d75f9441eff5f15648867","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura sanitarna, Baterie mechaniczne E","methodology":"Szczelność:","parameters":[{"name":"Zakres","range":"do 16 bar"},{"name":"przed zespołem zamykającym i szczelności zamknięcia"},{"name":"zamknięcia na przepływ krzyżowy między wodą gorącą i zimną"},{"name":"baterii za zespołem zamykającym"},{"name":"przełącznika ręcznego"},{"name":"przełącznika z samoczynnym powrotem"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność:\nZakres:\nZakres do 16 bar\nprzed zespołem zamykającym i szczelności zamknięcia\nzamknięcia na przepływ krzyżowy między wodą gorącą i zimną\nbaterii za zespołem zamykającym\nprzełącznika ręcznego\nprzełącznika z samoczynnym powrotem","reference":"PN-EN 817","norm_bases":["PN-EN 817"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura sanitarna, Baterie mechaniczne E Szczelność:\nZakres:\nZakres do 16 bar\nprzed zespołem zamykającym i szczelności zamknięcia\nzamknięcia na przepływ krzyżowy między wodą gorącą i zimną\nbaterii za zespołem zamykającym\nprzełącznika ręcznego\nprzełącznika z samoczynnym powrotem PN-EN 817 Armatura sanitarna, Baterie mechaniczne E Szczelnosc:\nZakres:\nZakres do 16 bar\nprzed zespolem zamykajacym i szczelnosci zamkniecia\nzamkniecia na przeplyw krzyzowy miedzy woda goraca i zimna\nbaterii za zespolem zamykajacym\nprzelacznika recznego\nprzelacznika z samoczynnym powrotem PN-EN 817","categories":["other"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Tightness:","parameters_en":[{"name":"Range","range":"do 16 bar"},{"name":"before the closing assembly and tightness of the closure"},{"name":"closures against cross-flow between hot and cold water"},{"name":"of the battery behind the locking assembly"},{"name":"manual switch"},{"name":"self-returning switch"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Sanitary tapware, Mechanical mixing valves E Tightness: Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range before the closing assembly and tightness of the closure closures against cross-flow between hot and cold water of the battery behind the locking assembly manual switch self-returning switch PN-EN 817","test_object_en":"Sanitary tapware, Mechanical mixing valves E","parameters_zh":[{"name":"范围","range":"do 16 bar"},{"name":"przed zespołem zamykającym i szczelności zamknięcia"},{"name":"zamknięcia na przepływ krzyżowy między wodą gorącą i zimną"},{"name":"baterii za zespołem zamykającym"},{"name":"przełącznika ręcznego"},{"name":"przełącznika z samoczynnym powrotem"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"卫生洁具配件、机械式龙头 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 817","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"卫生洁具配件、机械式龙头 E"},{"_id":"6a7d75f9441eff5f15648868","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura sanitarna, Baterie mechaniczne E","methodology":"Właściwości hydrauliczne:","parameters":[{"name":"dla temperatury","range":"do 90 °C"},{"name":"dla ciśnienia:","range":"do 5 bar"},{"name":"pomiar przepływu. Określenie Klasy przepływu"},{"name":"określenie czułości"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości hydrauliczne:\nZakres:\ndla temperatury do 90 °C\ndla ciśnienia: do 5 bar\npomiar przepływu. Określenie Klasy przepływu\nokreślenie czułości","reference":"PN-EN 817","norm_bases":["PN-EN 817"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura sanitarna, Baterie mechaniczne E Właściwości hydrauliczne:\nZakres:\ndla temperatury do 90 °C\ndla ciśnienia: do 5 bar\npomiar przepływu. Określenie Klasy przepływu\nokreślenie czułości PN-EN 817 Armatura sanitarna, Baterie mechaniczne E Wlasciwosci hydrauliczne:\nZakres:\ndla temperatury do 90 °C\ndla cisnienia: do 5 bar\npomiar przeplywu. Okreslenie Klasy przeplywu\nokreslenie czulosci PN-EN 817","categories":["other"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Hydraulic properties:","parameters_en":[{"name":"for temperature","range":"do 90 °C"},{"name":"for pressure:","range":"do 5 bar"},{"name":"flow measurement. Determination of the flow class"},{"name":"determination of sensitivity"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Sanitary tapware, Mechanical mixing valves E Hydraulic properties: Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. for temperature for pressure: flow measurement. Determination of the flow class determination of sensitivity PN-EN 817","test_object_en":"Sanitary tapware, Mechanical mixing valves E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"卫生洁具配件、机械式龙头 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 817","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"卫生洁具配件、机械式龙头 E"},{"_id":"6a7d75f9441eff5f15648869","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura sanitarna, Baterie mechaniczne E","methodology":"Odporność na zużycie mechaniczne:","parameters":[{"name":"badanie odporności elementu regulującego na zużycie mechaniczne"},{"name":"badanie przełącznika na zużycie mechaniczne"},{"name":"badanie ruchomej wylewki na zużycie mechaniczne"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zużycie mechaniczne:\nZakres:\nbadanie odporności elementu regulującego na zużycie mechaniczne\nbadanie przełącznika na zużycie mechaniczne\nbadanie ruchomej wylewki na zużycie mechaniczne","reference":"PN-EN 817","norm_bases":["PN-EN 817"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura sanitarna, Baterie mechaniczne E Odporność na zużycie mechaniczne:\nZakres:\nbadanie odporności elementu regulującego na zużycie mechaniczne\nbadanie przełącznika na zużycie mechaniczne\nbadanie ruchomej wylewki na zużycie mechaniczne PN-EN 817 Armatura sanitarna, Baterie mechaniczne E Odpornosc na zuzycie mechaniczne:\nZakres:\nbadanie odpornosci elementu regulujacego na zuzycie mechaniczne\nbadanie przelacznika na zuzycie mechaniczne\nbadanie ruchomej wylewki na zuzycie mechaniczne PN-EN 817","categories":["other"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Resistance to mechanical wear:","parameters_en":[{"name":"testing of the resistance of the control element to mechanical wear"},{"name":"testing of the switch for mechanical wear"},{"name":"testing of the swivel spout for mechanical wear"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Sanitary tapware, Mechanical mixing valves E Resistance to mechanical wear: Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. testing of the resistance of the control element to mechanical wear testing of the switch for mechanical wear testing of the swivel spout for mechanical wear PN-EN 817","test_object_en":"Sanitary tapware, Mechanical mixing valves E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"卫生洁具配件、机械式龙头 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 817","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"卫生洁具配件、机械式龙头 E"},{"_id":"6a7d75f9441eff5f1564886a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura sanitarna, Baterie mechaniczne E","methodology":"Właściwości mechaniczne:","parameters":[{"name":"odporność elementów regulacji na skręcanie"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości mechaniczne:\nodporność elementów regulacji na skręcanie","reference":"PN-EN 817","norm_bases":["PN-EN 817"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura sanitarna, Baterie mechaniczne E Właściwości mechaniczne:\nodporność elementów regulacji na skręcanie PN-EN 817 Armatura sanitarna, Baterie mechaniczne E Wlasciwosci mechaniczne:\nodpornosc elementow regulacji na skrecanie PN-EN 817","categories":["other"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Mechanical properties:","parameters_en":[{"name":"torsional resistance of the adjustment components"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Sanitary tapware, Mechanical mixing valves E Mechanical properties: Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. torsional resistance of the adjustment components PN-EN 817","test_object_en":"Sanitary tapware, Mechanical mixing valves E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"卫生洁具配件、机械式龙头 E 力学性能： 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 817","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","methodology_zh":"力学性能：","test_object_zh":"卫生洁具配件、机械式龙头 E"},{"_id":"6a7d75f9441eff5f1564886b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura sanitarna (natryski, przewody natryskowe) E","methodology":"Szczelność natrysków","parameters":[{"name":"Zakres","range":"do 5 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność natrysków\nZakres do 5 bar","reference":"PN-EN 1112","norm_bases":["PN-EN 1112"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura sanitarna (natryski, przewody natryskowe) E Szczelność natrysków\nZakres do 5 bar PN-EN 1112 Armatura sanitarna (natryski, przewody natryskowe) E Szczelnosc natryskow\nZakres do 5 bar PN-EN 1112","categories":["other"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Tightness of showers","parameters_en":[{"name":"Range","range":"do 5 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Sanitary tapware (showers, shower hoses) E Tightness of showers Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 1112","test_object_en":"Sanitary tapware (showers, shower hoses) E","parameters_zh":[{"name":"范围","range":"do 5 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"卫生洁具配件（淋浴器、淋浴软管）E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 1112","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"卫生洁具配件（淋浴器、淋浴软管）E"},{"_id":"6a7d75f9441eff5f1564886c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura sanitarna (natryski, przewody natryskowe) E","methodology":"Właściwości hydrauliczne:","parameters":[{"name":"pomiar przepływu. Określenie Klasy przepływu"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości hydrauliczne:\npomiar przepływu. Określenie Klasy przepływu","reference":"PN-EN 1112 | PN-EN 1113","norm_bases":["PN-EN 1112","PN-EN 1113"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura sanitarna (natryski, przewody natryskowe) E Właściwości hydrauliczne:\npomiar przepływu. Określenie Klasy przepływu PN-EN 1112 | PN-EN 1113 Armatura sanitarna (natryski, przewody natryskowe) E Wlasciwosci hydrauliczne:\npomiar przeplywu. Okreslenie Klasy przeplywu PN-EN 1112 | PN-EN 1113","categories":["other"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Hydraulic properties:","parameters_en":[{"name":"flow measurement. Determination of the flow class"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Sanitary tapware (showers, shower hoses) E Hydraulic properties: Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. flow measurement. Determination of the flow class PN-EN 1112 | PN-EN 1113","test_object_en":"Sanitary tapware (showers, shower hoses) E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"卫生洁具配件（淋浴器、淋浴软管）E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1112 | PN-EN 1113","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"卫生洁具配件（淋浴器、淋浴软管）E"},{"_id":"6a7d75f9441eff5f1564886d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Armatura sanitarna (natryski, przewody natryskowe) E","methodology":"Właściwości mechaniczne:","parameters":[{"name":"wytrzymałość przewodu na rozciąganie"},{"name":"wytrzymałość przewodu natryskowego na zginanie"},{"name":"wytrzymałość mechaniczna wylotu natryskowego"},{"name":"odporność wylotu natryskowego i przewodu na zmiany temperatury"},{"name":"wytrzymałość przewodu na ciśnienie w podwyższonej temperaturze"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości mechaniczne:\nZakres:\nwytrzymałość przewodu na rozciąganie\nwytrzymałość przewodu natryskowego na zginanie\nwytrzymałość mechaniczna wylotu natryskowego\nodporność wylotu natryskowego i przewodu na zmiany temperatury\nwytrzymałość przewodu na ciśnienie w podwyższonej temperaturze","reference":"PN-EN 1112 | PN-EN 1113","norm_bases":["PN-EN 1112","PN-EN 1113"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Armatura sanitarna (natryski, przewody natryskowe) E Właściwości mechaniczne:\nZakres:\nwytrzymałość przewodu na rozciąganie\nwytrzymałość przewodu natryskowego na zginanie\nwytrzymałość mechaniczna wylotu natryskowego\nodporność wylotu natryskowego i przewodu na zmiany temperatury\nwytrzymałość przewodu na ciśnienie w podwyższonej temperaturze PN-EN 1112 | PN-EN 1113 Armatura sanitarna (natryski, przewody natryskowe) E Wlasciwosci mechaniczne:\nZakres:\nwytrzymalosc przewodu na rozciaganie\nwytrzymalosc przewodu natryskowego na zginanie\nwytrzymalosc mechaniczna wylotu natryskowego\nodpornosc wylotu natryskowego i przewodu na zmiany temperatury\nwytrzymalosc przewodu na cisnienie w podwyzszonej temperaturze PN-EN 1112 | PN-EN 1113","categories":["other"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Mechanical properties:","parameters_en":[{"name":"tensile strength of the hose"},{"name":"bending strength of the spray hose"},{"name":"mechanical strength of the spray outlet"},{"name":"resistance of the spray outlet and hose to temperature changes"},{"name":"pressure strength of the hose at elevated temperature"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Sanitary tapware (showers, shower hoses) E Mechanical properties: Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. tensile strength of the hose bending strength of the spray hose mechanical strength of the spray outlet resistance of the spray outlet and hose to temperature changes pressure strength of the hose at elevated temperature PN-EN 1112 | PN-EN 1113","test_object_en":"Sanitary tapware (showers, shower hoses) E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"卫生洁具配件（淋浴器、淋浴软管）E 力学性能： 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1112 | PN-EN 1113","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","methodology_zh":"力学性能：","test_object_zh":"卫生洁具配件（淋浴器、淋浴软管）E"},{"_id":"6a7d75f9441eff5f1564886e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Odporność materiałów powłokowych i powłok na starzenie i termiczne","parameters":[{"name":"Zakres","range":"do 200 ± 2 °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność materiałów powłokowych i powłok na starzenie i termiczne\nZakres do 200 ± 2 °C","reference":"PN-EN 12068 | PN-EN 10290 | PN-EN ISO 21809-1","norm_bases":["PN-EN 12068","PN-EN 10290","PN-EN ISO 21809-1"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Odporność materiałów powłokowych i powłok na starzenie i termiczne\nZakres do 200 ± 2 °C PN-EN 12068 | PN-EN 10290 | PN-EN ISO 21809-1 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Odpornosc materialow powlokowych i powlok na starzenie i termiczne\nZakres do 200 ± 2 °C PN-EN 12068 | PN-EN 10290 | PN-EN ISO 21809-1","categories":["materials"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Resistance of coating materials and coatings to ageing and thermal","parameters_en":[{"name":"Range","range":"do 200 ± 2 °C"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Resistance of coating materials and coatings to ageing and thermal Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN 12068 | PN-EN 10290 | PN-EN ISO 21809-1","test_object_en":"Protective plastic coatings on steel pipes and fittings E","parameters_zh":[{"name":"范围","range":"do 200 ± 2 °C"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12068 | PN-EN 10290 | PN-EN ISO 21809-1","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f1564886f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Grubość materiałów powłokowych i powłok","parameters":[{"name":"Zakres","range":"(0 – 15) mm"}],"technique":"Metoda Indukcyjna","techniques":["Metoda Indukcyjna"],"computed":[],"activity":"Grubość materiałów powłokowych i powłok\nZakres (0 – 15) mm\nMetoda Indukcyjna","reference":"PN-EN ISO 2808 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","norm_bases":["PN-EN ISO 2808","PN-EN 10290","DIN 30670-1","DIN 30670-2","PN-EN ISO 21809-1"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Grubość materiałów powłokowych i powłok\nZakres (0 – 15) mm\nMetoda Indukcyjna PN-EN ISO 2808 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Grubosc materialow powlokowych i powlok\nZakres (0 – 15) mm\nMetoda Indukcyjna PN-EN ISO 2808 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","categories":["materials"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Thickness of coating materials and coatings","parameters_en":[{"name":"Range","range":"(0 – 15) mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Thickness of coating materials and coatings Inductive method Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN ISO 2808 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","technique_en":"Inductive method","test_object_en":"Protective plastic coatings on steel pipes and fittings E","parameters_zh":[{"name":"范围","range":"(0 – 15) mm"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN ISO 2808 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f15648870","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Właściwości wytrzymałościowe materiałów powłokowych i powłok:","parameters":[{"name":"odciążenie zrywające"},{"name":"wydłużenie względne przy zerwaniu,"},{"name":"Zakres","range":"do 20 kN"},{"name":"Badania w temp. 23 ± 3 °C Próba rozciągania"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości wytrzymałościowe materiałów powłokowych i powłok:\nZakres:\nodciążenie zrywające\nwydłużenie względne przy zerwaniu,\nZakres do 20 kN\nBadania w temp. 23 ± 3 °C Próba rozciągania","reference":"PN-EN ISO 527-1 | PN-EN ISO 527-2 | PN-EN ISO 527-3 | PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2","norm_bases":["PN-EN ISO 527-1","PN-EN ISO 527-2","PN-EN ISO 527-3","PN-EN 12068","PN-EN 10290","DIN 30670-1","DIN 30670-2"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Właściwości wytrzymałościowe materiałów powłokowych i powłok:\nZakres:\nodciążenie zrywające\nwydłużenie względne przy zerwaniu,\nZakres do 20 kN\nBadania w temp. 23 ± 3 °C Próba rozciągania PN-EN ISO 527-1 | PN-EN ISO 527-2 | PN-EN ISO 527-3 | PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Wlasciwosci wytrzymalosciowe materialow powlokowych i powlok:\nZakres:\nodciazenie zrywajace\nwydluzenie wzgledne przy zerwaniu,\nZakres do 20 kN\nBadania w temp. 23 ± 3 °C Proba rozciagania PN-EN ISO 527-1 | PN-EN ISO 527-2 | PN-EN ISO 527-3 | PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2","categories":["materials"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Strength properties of coating materials and coatings:","parameters_en":[{"name":"breaking load"},{"name":"percentage elongation at break,"},{"name":"Range","range":"do 20 kN"},{"name":"Tests at temp. 23 ± 3 °C Tensile test"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Strength properties of coating materials and coatings: Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. breaking load percentage elongation at break, Range Tests at temp. 23 ± 3 °C Tensile test PN-EN ISO 527-1 | PN-EN ISO 527-2 | PN-EN ISO 527-3 | PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2","test_object_en":"Protective plastic coatings on steel pipes and fittings E","parameters_zh":[{"name":"odciążenie zrywające"},{"name":"wydłużenie względne przy zerwaniu,"},{"name":"范围","range":"do 20 kN"},{"name":"Badania w temp. 23 ± 3 °C Próba rozciągania"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN ISO 527-1 | PN-EN ISO 527-2 | PN-EN ISO 527-3 | PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f15648871","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Szczelność (brak porów) powłoki","parameters":[{"name":"Zakres","range":"do 30 kV"},{"name":"Próba przebicia napięciem stałym"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność (brak porów) powłoki\nZakres:\nZakres do 30 kV\nPróba przebicia napięciem stałym","reference":"PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2","norm_bases":["PN-EN 12068","PN-EN 10290","DIN 30670-1","DIN 30670-2","PN-EN ISO 21809-1","PN-EN ISO 21809-2"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Szczelność (brak porów) powłoki\nZakres:\nZakres do 30 kV\nPróba przebicia napięciem stałym PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Szczelnosc (brak porow) powloki\nZakres:\nZakres do 30 kV\nProba przebicia napieciem stalym PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2","categories":["materials"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Tightness (absence of pores) of the coating","parameters_en":[{"name":"Range","range":"do 30 kV"},{"name":"Direct voltage breakdown test"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Tightness (absence of pores) of the coating Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range Direct voltage breakdown test PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2","test_object_en":"Protective plastic coatings on steel pipes and fittings E","parameters_zh":[{"name":"范围","range":"do 30 kV"},{"name":"Próba przebicia napięciem stałym"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f15648872","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Odporność powłoki na wgniatanie","parameters":[{"name":"Zakres","range":"(0 – 10) mm"},{"name":"Próba wgniatania"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność powłoki na wgniatanie\nZakres:\nZakres (0 – 10) mm\nPróba wgniatania","reference":"PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","norm_bases":["PN-EN 12068","PN-EN 10290","DIN 30670-1","DIN 30670-2","PN-EN ISO 21809-1"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Odporność powłoki na wgniatanie\nZakres:\nZakres (0 – 10) mm\nPróba wgniatania PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Odpornosc powloki na wgniatanie\nZakres:\nZakres (0 – 10) mm\nProba wgniatania PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","categories":["materials"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Indentation resistance of the coating","parameters_en":[{"name":"Range","range":"(0 – 10) mm"},{"name":"Indentation test"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Indentation resistance of the coating Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range Indentation test PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","test_object_en":"Protective plastic coatings on steel pipes and fittings E","parameters_zh":[{"name":"范围","range":"(0 – 10) mm"},{"name":"Próba wgniatania"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f15648873","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Odporność powłoki na uderzenie","parameters":[{"name":"Zakres wysokości spadku","range":"1,5 m"},{"name":"Masa ciężarka","range":"1000 g, 2000 g"}],"technique":"Metoda spadającego ciężarka","techniques":["Metoda spadającego ciężarka"],"computed":[],"activity":"Odporność powłoki na uderzenie\nZakres:\nZakres wysokości spadku 1,5 m\nMasa ciężarka 1000 g, 2000 g\nMetoda spadającego ciężarka","reference":"PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","norm_bases":["PN-EN 12068","PN-EN 10290","DIN 30670-1","DIN 30670-2","PN-EN ISO 21809-1"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Odporność powłoki na uderzenie\nZakres:\nZakres wysokości spadku 1,5 m\nMasa ciężarka 1000 g, 2000 g\nMetoda spadającego ciężarka PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Odpornosc powloki na uderzenie\nZakres:\nZakres wysokosci spadku 1,5 m\nMasa ciezarka 1000 g, 2000 g\nMetoda spadajacego ciezarka PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","categories":["materials"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Impact resistance of the coating","parameters_en":[{"name":"Range of drop height","range":"1,5 m"},{"name":"Weight mass","range":"1000 g, 2000 g"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Impact resistance of the coating Falling weight method Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range of drop height Weight mass PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","technique_en":"Falling weight method","test_object_en":"Protective plastic coatings on steel pipes and fittings E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 落锤法 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E","technique_zh":"落锤法"},{"_id":"6a7d75f9441eff5f15648874","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Przyczepność międzywarstwowa powłoki z materiału nawojowego i termokurczliwego","parameters":[{"name":"Zakres","range":"do 20 kN"},{"name":"Próba odrywania"}],"technique":null,"techniques":[],"computed":[],"activity":"Przyczepność międzywarstwowa powłoki z materiału nawojowego i termokurczliwego\nZakres:\nZakres do 20 kN\nPróba odrywania","reference":"PN-EN 12068","norm_bases":["PN-EN 12068"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Przyczepność międzywarstwowa powłoki z materiału nawojowego i termokurczliwego\nZakres:\nZakres do 20 kN\nPróba odrywania PN-EN 12068 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Przyczepnosc miedzywarstwowa powloki z materialu nawojowego i termokurczliwego\nZakres:\nZakres do 20 kN\nProba odrywania PN-EN 12068","categories":["materials"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Interlayer adhesion of the coating made of wrapping and heat-shrinkable material","parameters_en":[{"name":"Range","range":"do 20 kN"},{"name":"Pull-off test"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Interlayer adhesion of the coating made of wrapping and heat-shrinkable material Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range Pull-off test PN-EN 12068","test_object_en":"Protective plastic coatings on steel pipes and fittings E","parameters_zh":[{"name":"范围","range":"do 20 kN"},{"name":"Próba odrywania"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12068","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f15648875","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Przyczepność powłoki do powierzchni podpowłokowej: rury stalowej, powłoki PE - wytłaczanej, innej powłoki roboczej","parameters":[{"name":"Zakres","range":"do 20 kN"},{"name":"Temperatura 20 ± 3 °C Próba odrywania"}],"technique":null,"techniques":[],"computed":[],"activity":"Przyczepność powłoki do powierzchni podpowłokowej: rury stalowej, powłoki PE - wytłaczanej, innej powłoki roboczej\nZakres:\nZakres do 20 kN\nTemperatura 20 ± 3 °C Próba odrywania","reference":"PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","norm_bases":["PN-EN 12068","DIN 30670-1","DIN 30670-2","PN-EN ISO 21809-1"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Przyczepność powłoki do powierzchni podpowłokowej: rury stalowej, powłoki PE - wytłaczanej, innej powłoki roboczej\nZakres:\nZakres do 20 kN\nTemperatura 20 ± 3 °C Próba odrywania PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Przyczepnosc powloki do powierzchni podpowlokowej: rury stalowej, powloki PE - wytlaczanej, innej powloki roboczej\nZakres:\nZakres do 20 kN\nTemperatura 20 ± 3 °C Proba odrywania PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","categories":["materials"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Adhesion of the coating to the sub-coating surface: steel pipe, extruded PE coating, other working coating","parameters_en":[{"name":"Range","range":"do 20 kN"},{"name":"Temperature 20 ± 3 °C Peel test"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Adhesion of the coating to the sub-coating surface: steel pipe, extruded PE coating, other working coating Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range Temperature 20 ± 3 °C Peel test PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","test_object_en":"Protective plastic coatings on steel pipes and fittings E","parameters_zh":[{"name":"范围","range":"do 20 kN"},{"name":"Temperatura 20 ± 3 °C Próba odrywania"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f15648876","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Wytrzymałość powłoki na zsuwanie (ścinanie) z powierzchni podpowłokowej: stali, powłoki PE - wytłaczanej, innej powłoki","parameters":[{"name":"roboczej"},{"name":"Próba ścinania"},{"name":"Zakres","range":"do 20 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość powłoki na zsuwanie (ścinanie) z powierzchni podpowłokowej: stali, powłoki PE - wytłaczanej, innej powłoki\nZakres:\nroboczej\nPróba ścinania\nZakres do 20 kN","reference":"PN-EN 12068","norm_bases":["PN-EN 12068"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Wytrzymałość powłoki na zsuwanie (ścinanie) z powierzchni podpowłokowej: stali, powłoki PE - wytłaczanej, innej powłoki\nZakres:\nroboczej\nPróba ścinania\nZakres do 20 kN PN-EN 12068 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Wytrzymalosc powloki na zsuwanie (scinanie) z powierzchni podpowlokowej: stali, powloki PE - wytlaczanej, innej powloki\nZakres:\nroboczej\nProba scinania\nZakres do 20 kN PN-EN 12068","categories":["materials"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Resistance of the coating to slippage (shear) from the substrate surface: steel, extruded PE coating, another coating","parameters_en":[{"name":"working"},{"name":"Shear test"},{"name":"Range","range":"do 20 kN"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Resistance of the coating to slippage (shear) from the substrate surface: steel, extruded PE coating, another coating Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. working Shear test Range PN-EN 12068","test_object_en":"Protective plastic coatings on steel pipes and fittings E","parameters_zh":[{"name":"roboczej"},{"name":"Próba ścinania"},{"name":"范围","range":"do 20 kN"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN 12068","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f15648877","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Jednostkowa rezystancja powłoki","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Jednostkowa rezystancja powłoki","reference":"PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN 10290","norm_bases":["PN-EN 12068","DIN 30670-1","DIN 30670-2","PN-EN 10290"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Jednostkowa rezystancja powłoki PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN 10290 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Jednostkowa rezystancja powloki PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN 10290","categories":["materials"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Unit resistance of the coating","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Unit resistance of the coating Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN 10290","test_object_en":"Protective plastic coatings on steel pipes and fittings E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12068 | DIN 30670-1 | DIN 30670-2 | PN-EN 10290","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f15648878","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Masowy (MFR) wskaźnik szybkości płynięcia tworzywa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Masowy (MFR) wskaźnik szybkości płynięcia tworzywa","reference":"PN-EN ISO 1133-1 | DIN 30670","norm_bases":["PN-EN ISO 1133-1","DIN 30670"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Masowy (MFR) wskaźnik szybkości płynięcia tworzywa PN-EN ISO 1133-1 | DIN 30670 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Masowy (MFR) wskaznik szybkosci plyniecia tworzywa PN-EN ISO 1133-1 | DIN 30670","categories":["materials"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Mass (MFR) melt flow rate of the plastic","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Mass (MFR) melt flow rate of the plastic Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 1133-1 | DIN 30670","test_object_en":"Protective plastic coatings on steel pipes and fittings E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 1133-1 | DIN 30670","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f15648879","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E","methodology":"Odporność uszkodzonej powłoki na korozję podpowłokową wskutek utraty przyczepności do stali lub rozwarstwienia powłoki pod wpływem prądu katodowej polaryzacji stali","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność uszkodzonej powłoki na korozję podpowłokową wskutek utraty przyczepności do stali lub rozwarstwienia powłoki pod wpływem prądu katodowej polaryzacji stali","reference":"PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2","norm_bases":["PN-EN 12068","PN-EN 10290","DIN 30670-1","DIN 30670-2","PN-EN ISO 21809-1","PN-EN ISO 21809-2"],"lab_section":"Laboratorium Badań Armatury i Technik Eksploatacji Gazociągów (GP-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Powłoki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Odporność uszkodzonej powłoki na korozję podpowłokową wskutek utraty przyczepności do stali lub rozwarstwienia powłoki pod wpływem prądu katodowej polaryzacji stali PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2 Powloki ochronne z tworzyw sztucznych na rurach i armaturze stalowej E Odpornosc uszkodzonej powloki na korozje podpowlokowa wskutek utraty przyczepnosci do stali lub rozwarstwienia powloki pod wplywem pradu katodowej polaryzacji stali PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2","categories":["materials"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1)","methodology_en":"Resistance of a damaged coating to under-film corrosion resulting from loss of adhesion to steel or coating disbonding under the influence of the cathodic polarisation current of the steel","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Protective plastic coatings on steel pipes and fittings E Resistance of a damaged coating to under-film corrosion resulting from loss of adhesion to steel or coating disbonding under the influence of the cathodic polarisation current of the steel Gas Pipeline Fittings and Operation Techniques Testing Laboratory (GP-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2","test_object_en":"Protective plastic coatings on steel pipes and fittings E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"钢管与钢制配件上的塑料防护涂层 E 燃气管道阀门与运行技术检测实验室（GP-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12068 | PN-EN 10290 | DIN 30670-1 | DIN 30670-2 | PN-EN ISO 21809-1 | PN-EN ISO 21809-2","lab_section_zh":"燃气管道阀门与运行技术检测实验室（GP-1）","test_object_zh":"钢管与钢制配件上的塑料防护涂层 E"},{"_id":"6a7d75f9441eff5f1564887a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury i kształtki z tworzyw termoplastycznych, Systemy rur wielowarstwowych i złączek","methodology":"Odporność na cykliczne zmiany temperatury","parameters":[{"name":"temperatura","range":"do 95 °C"}],"technique":"Metoda z zastosowaniem cyklicznego działania temperatury","techniques":["Metoda z zastosowaniem cyklicznego działania temperatury"],"computed":[],"activity":"Odporność na cykliczne zmiany temperatury\ntemperatura do 95 °C\nMetoda z zastosowaniem cyklicznego działania temperatury","reference":"PN-EN 12293:2002","norm_bases":["PN-EN 12293:2002"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rury i kształtki z tworzyw termoplastycznych, Systemy rur wielowarstwowych i złączek Odporność na cykliczne zmiany temperatury\ntemperatura do 95 °C\nMetoda z zastosowaniem cyklicznego działania temperatury PN-EN 12293:2002 Rury i ksztaltki z tworzyw termoplastycznych, Systemy rur wielowarstwowych i zlaczek Odpornosc na cykliczne zmiany temperatury\ntemperatura do 95 °C\nMetoda z zastosowaniem cyklicznego dzialania temperatury PN-EN 12293:2002","categories":["other"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Resistance to cyclic temperature changes","parameters_en":[{"name":"temperature","range":"do 95 °C"}],"search_en":"Thermoplastics pipes and fittings, Multilayer piping systems and fittings Resistance to cyclic temperature changes Method using cyclic temperature action Plastics Laboratory (GP-3) temperature PN-EN 12293:2002","technique_en":"Method using cyclic temperature action","test_object_en":"Thermoplastics pipes and fittings, Multilayer piping systems and fittings","parameters_zh":[{"name":"温度","range":"do 95 °C"}],"search_zh":"耐温度循环变化性 塑料实验室（GP-3） 温度 PN-EN 12293:2002","lab_section_zh":"塑料实验室（GP-3）","methodology_zh":"耐温度循环变化性"},{"_id":"6a7d75f9441eff5f1564887b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Tworzywa sztuczne nieporowate, Rury, kształtki i inne wyroby z tworzyw sztucznych nieporowatych E","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,1 – 1) g/cm3"}],"technique":"Metoda zanurzeniowa","techniques":["Metoda zanurzeniowa"],"computed":[],"activity":"Gęstość\nZakres (0,1 – 1) g/cm3\nMetoda zanurzeniowa","reference":"PN-EN ISO 1183-1","norm_bases":["PN-EN ISO 1183-1"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Tworzywa sztuczne nieporowate, Rury, kształtki i inne wyroby z tworzyw sztucznych nieporowatych E Gęstość\nZakres (0,1 – 1) g/cm3\nMetoda zanurzeniowa PN-EN ISO 1183-1 Tworzywa sztuczne nieporowate, Rury, ksztaltki i inne wyroby z tworzyw sztucznych nieporowatych E Gestosc\nZakres (0,1 – 1) g/cm3\nMetoda zanurzeniowa PN-EN ISO 1183-1","categories":["materials"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,1 – 1) g/cm3"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Non-cellular plastics, Pipes, fittings and other products made of non-cellular plastics E Density Immersion method Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Range PN-EN ISO 1183-1","technique_en":"Immersion method","test_object_en":"Non-cellular plastics, Pipes, fittings and other products made of non-cellular plastics E","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,1 – 1) g/cm3"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"密度 浸没法 塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 范围 PN-EN ISO 1183-1","lab_section_zh":"塑料实验室（GP-3）","technique_zh":"浸没法"},{"_id":"6a7d75f9441eff5f1564887c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Tworzywa termoplastyczne, Rury, kształtki i inne wyroby z tworzyw termoplastycznych E","methodology":"Masowy wskaźnik szybkości płynięcia (MFR)","parameters":[{"name":"obciążenie","range":"2,16 kg i 5 kg"}],"technique":"Metoda plastometryczna","techniques":["Metoda plastometryczna"],"computed":[],"activity":"Masowy wskaźnik szybkości płynięcia (MFR)\nobciążenie 2,16 kg i 5 kg\nMetoda plastometryczna","reference":"PN-EN ISO 1133-1","norm_bases":["PN-EN ISO 1133-1"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Tworzywa termoplastyczne, Rury, kształtki i inne wyroby z tworzyw termoplastycznych E Masowy wskaźnik szybkości płynięcia (MFR)\nobciążenie 2,16 kg i 5 kg\nMetoda plastometryczna PN-EN ISO 1133-1 Tworzywa termoplastyczne, Rury, ksztaltki i inne wyroby z tworzyw termoplastycznych E Masowy wskaznik szybkosci plyniecia (MFR)\nobciazenie 2,16 kg i 5 kg\nMetoda plastometryczna PN-EN ISO 1133-1","categories":["materials"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Melt mass-flow rate (MFR)","parameters_en":[{"name":"load","range":"2,16 kg i 5 kg"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Thermoplastics, Pipes, fittings and other thermoplastic products E Melt mass-flow rate (MFR) Plastometric method Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. load PN-EN ISO 1133-1","technique_en":"Plastometric method","test_object_en":"Thermoplastics, Pipes, fittings and other thermoplastic products E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 荷载 PN-EN ISO 1133-1","lab_section_zh":"塑料实验室（GP-3）","parameters_zh":[{"name":"荷载","range":"2,16 kg i 5 kg"}]},{"_id":"6a7d75f9441eff5f1564887d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury z tworzyw termoplastycznych E","methodology":"Właściwości mechaniczne przy rozciąganiu","parameters":[{"name":"wydłużenie przy zerwaniu"},{"name":"Obciążenie","range":"do 20 kN"},{"name":"Wydłużenie","range":"do 1200 %"},{"name":"Statyczna próba rozciągania"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości mechaniczne przy rozciąganiu\nZakres:\nwydłużenie przy zerwaniu\nObciążenie do 20 kN\nWydłużenie do 1200 %\nStatyczna próba rozciągania","reference":"PN-EN ISO 6259-1","norm_bases":["PN-EN ISO 6259-1"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury z tworzyw termoplastycznych E Właściwości mechaniczne przy rozciąganiu\nZakres:\nwydłużenie przy zerwaniu\nObciążenie do 20 kN\nWydłużenie do 1200 %\nStatyczna próba rozciągania PN-EN ISO 6259-1 Rury z tworzyw termoplastycznych E Wlasciwosci mechaniczne przy rozciaganiu\nZakres:\nwydluzenie przy zerwaniu\nObciazenie do 20 kN\nWydluzenie do 1200 %\nStatyczna proba rozciagania PN-EN ISO 6259-1","categories":["other"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Tensile mechanical properties","parameters_en":[{"name":"elongation at fracture"},{"name":"Load","range":"do 20 kN"},{"name":"Elongation","range":"do 1200 %"},{"name":"Static tensile test"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Thermoplastic pipes E Tensile mechanical properties Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. elongation at fracture Load Elongation Static tensile test PN-EN ISO 6259-1","test_object_en":"Thermoplastic pipes E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"拉伸力学性能 塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 断裂伸长率 荷载 PN-EN ISO 6259-1","lab_section_zh":"塑料实验室（GP-3）","parameters_zh":[{"name":"断裂伸长率"},{"name":"荷载","range":"do 20 kN"},{"name":"Wydłużenie","range":"do 1200 %"},{"name":"Statyczna próba rozciągania"}],"methodology_zh":"拉伸力学性能"},{"_id":"6a7d75f9441eff5f1564887e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury kształtki i zestawy z termoplastycznych tworzyw sztucznych, Systemy rur wielowarstwowych i złączek, Połączenia PE/Metal, Przyłącza domowe do gazu E","methodology":"Wytrzymałość na ciśnienie wewnętrzne","parameters":[{"name":"średnica","range":"do 630 mm"}],"technique":"Metoda woda w wodzie i woda w powietrzu","techniques":["Metoda woda w wodzie i woda w powietrzu"],"computed":[],"activity":"Wytrzymałość na ciśnienie wewnętrzne\nśrednica do 630 mm\nMetoda woda w wodzie i woda w powietrzu","reference":"PN-EN ISO 1167-1","norm_bases":["PN-EN ISO 1167-1"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury kształtki i zestawy z termoplastycznych tworzyw sztucznych, Systemy rur wielowarstwowych i złączek, Połączenia PE/Metal, Przyłącza domowe do gazu E Wytrzymałość na ciśnienie wewnętrzne\nśrednica do 630 mm\nMetoda woda w wodzie i woda w powietrzu PN-EN ISO 1167-1 Rury ksztaltki i zestawy z termoplastycznych tworzyw sztucznych, Systemy rur wielowarstwowych i zlaczek, Polaczenia PE/Metal, Przylacza domowe do gazu E Wytrzymalosc na cisnienie wewnetrzne\nsrednica do 630 mm\nMetoda woda w wodzie i woda w powietrzu PN-EN ISO 1167-1","categories":["materials","water"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Resistance to internal pressure","parameters_en":[{"name":"diameter","range":"do 630 mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Thermoplastics pipes, fittings and assemblies, Multilayer piping systems and fittings, PE/Metal joints, Domestic gas service connections E Resistance to internal pressure Water-in-water and water-in-air method Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. diameter PN-EN ISO 1167-1","technique_en":"Water-in-water and water-in-air method","test_object_en":"Thermoplastics pipes, fittings and assemblies, Multilayer piping systems and fittings, PE/Metal joints, Domestic gas service connections E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"内压强度 塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 直径 PN-EN ISO 1167-1","lab_section_zh":"塑料实验室（GP-3）","parameters_zh":[{"name":"直径","range":"do 630 mm"}],"methodology_zh":"内压强度"},{"_id":"6a7d75f9441eff5f1564887f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury, kształtki i inne wyroby z tworzyw sztucznych, Systemy rur wielowarstwowych, Połączenia PE/Metal, Przyłącza domowe do gazu E","methodology":"Wymiary","parameters":[{"name":"średnica"},{"name":"grubość ścianki"},{"name":"owalność"},{"name":"długość"},{"name":"średnica","range":"15 – 630 mm"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wymiary\nZakres:\nśrednica\ngrubość ścianki\nowalność\ndługość\nśrednica 15 – 630 mm\nMetoda bezpośrednia","reference":"PN-EN ISO 3126","norm_bases":["PN-EN ISO 3126"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury, kształtki i inne wyroby z tworzyw sztucznych, Systemy rur wielowarstwowych, Połączenia PE/Metal, Przyłącza domowe do gazu E Wymiary\nZakres:\nśrednica\ngrubość ścianki\nowalność\ndługość\nśrednica 15 – 630 mm\nMetoda bezpośrednia PN-EN ISO 3126 Rury, ksztaltki i inne wyroby z tworzyw sztucznych, Systemy rur wielowarstwowych, Polaczenia PE/Metal, Przylacza domowe do gazu E Wymiary\nZakres:\nsrednica\ngrubosc scianki\nowalnosc\ndlugosc\nsrednica 15 – 630 mm\nMetoda bezposrednia PN-EN ISO 3126","categories":["materials"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Dimensions","parameters_en":[{"name":"diameter"},{"name":"wall thickness"},{"name":"ovality"},{"name":"length"},{"name":"diameter","range":"15 – 630 mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Plastics pipes, fittings and other products, Multilayer piping systems, PE/Metal joints, Domestic gas service connections E Dimensions Direct method Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. diameter wall thickness ovality length diameter PN-EN ISO 3126","technique_en":"Direct method","test_object_en":"Plastics pipes, fittings and other products, Multilayer piping systems, PE/Metal joints, Domestic gas service connections E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"尺寸 直接法 塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 直径 长度 直径 PN-EN ISO 3126","methodology_zh":"尺寸","technique_zh":"直接法","lab_section_zh":"塑料实验室（GP-3）","parameters_zh":[{"name":"直径"},{"name":"grubość ścianki"},{"name":"owalność"},{"name":"长度"},{"name":"直径","range":"15 – 630 mm"}]},{"_id":"6a7d75f9441eff5f15648880","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury i kształtki z polietylenu E","methodology":"Wytrzymałość zgrzewu doczołowego na rozciąganie","parameters":[{"name":"Maksymalne obciążenie","range":"do 20 kN"}],"technique":"Metoda statycznej próby rozciągania","techniques":["Metoda statycznej próby rozciągania"],"computed":[],"activity":"Wytrzymałość zgrzewu doczołowego na rozciąganie\nMaksymalne obciążenie do 20 kN\nMetoda statycznej próby rozciągania","reference":"ISO 13953","norm_bases":["ISO 13953"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury i kształtki z polietylenu E Wytrzymałość zgrzewu doczołowego na rozciąganie\nMaksymalne obciążenie do 20 kN\nMetoda statycznej próby rozciągania ISO 13953 Rury i ksztaltki z polietylenu E Wytrzymalosc zgrzewu doczolowego na rozciaganie\nMaksymalne obciazenie do 20 kN\nMetoda statycznej proby rozciagania ISO 13953","categories":["other"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Tensile strength of the butt-fused joint","parameters_en":[{"name":"Maximum load","range":"do 20 kN"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Polyethylene pipes and fittings E Tensile strength of the butt-fused joint Static tensile test method Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Maximum load ISO 13953","technique_en":"Static tensile test method","test_object_en":"Polyethylene pipes and fittings E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 ISO 13953","lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f15648881","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury z tworzyw termoplastycznych E","methodology":"Skurcz wzdłużny","parameters":[{"name":"temperatura max 120 °C Grubość ścianki","range":"do 16 mm"}],"technique":"Metoda z zastosowaniem komory grzejnej","techniques":["Metoda z zastosowaniem komory grzejnej"],"computed":[],"activity":"Skurcz wzdłużny\ntemperatura max 120 °C Grubość ścianki do 16 mm\nMetoda z zastosowaniem komory grzejnej","reference":"PN-EN ISO 2505","norm_bases":["PN-EN ISO 2505"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury z tworzyw termoplastycznych E Skurcz wzdłużny\ntemperatura max 120 °C Grubość ścianki do 16 mm\nMetoda z zastosowaniem komory grzejnej PN-EN ISO 2505 Rury z tworzyw termoplastycznych E Skurcz wzdluzny\ntemperatura max 120 °C Grubosc scianki do 16 mm\nMetoda z zastosowaniem komory grzejnej PN-EN ISO 2505","categories":["other"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Longitudinal shrinkage","parameters_en":[{"name":"temperature max 120 °C Wall thickness","range":"do 16 mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Thermoplastic pipes E Longitudinal shrinkage Method using a heating chamber Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. temperature max 120 °C Wall thickness PN-EN ISO 2505","technique_en":"Method using a heating chamber","test_object_en":"Thermoplastic pipes E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 2505","lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f15648882","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury z polietylenu E","methodology":"Skurcz obwodowy","parameters":[{"name":"Maksymalna średnica 630 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Skurcz obwodowy\nMaksymalna średnica 630 mm","reference":"PN-EN 1555-2 pkt.9.3","norm_bases":["PN-EN 1555-2 pkt.9.3"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury z polietylenu E Skurcz obwodowy\nMaksymalna średnica 630 mm PN-EN 1555-2 pkt.9.3 Rury z polietylenu E Skurcz obwodowy\nMaksymalna srednica 630 mm PN-EN 1555-2 pkt.9.3","categories":["other"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Circumferential shrinkage","parameters_en":[{"name":"Maximum diameter 630 mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Polyethylene pipes E Circumferential shrinkage Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Maximum diameter 630 mm PN-EN 1555-2 pkt.9.3","test_object_en":"Polyethylene pipes E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1555-2 pkt.9.3","lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f15648883","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury z polietylenu E","methodology":"Odporność na zaciskanie","parameters":[{"name":"średnica","range":"do 110 mm"}],"technique":"Metoda woda w wodzie i woda w powietrzu","techniques":["Metoda woda w wodzie i woda w powietrzu"],"computed":[],"activity":"Odporność na zaciskanie\nśrednica do 110 mm\nMetoda woda w wodzie i woda w powietrzu","reference":"PN-EN 12106","norm_bases":["PN-EN 12106"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury z polietylenu E Odporność na zaciskanie\nśrednica do 110 mm\nMetoda woda w wodzie i woda w powietrzu PN-EN 12106 Rury z polietylenu E Odpornosc na zaciskanie\nsrednica do 110 mm\nMetoda woda w wodzie i woda w powietrzu PN-EN 12106","categories":["water"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Resistance to squeezing","parameters_en":[{"name":"diameter","range":"do 110 mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Polyethylene pipes E Resistance to squeezing Water-in-water and water-in-air method Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. diameter PN-EN 12106","technique_en":"Water-in-water and water-in-air method","test_object_en":"Polyethylene pipes E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 直径 PN-EN 12106","lab_section_zh":"塑料实验室（GP-3）","parameters_zh":[{"name":"直径","range":"do 110 mm"}]},{"_id":"6a7d75f9441eff5f15648884","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury z poliolefin E","methodology":"Odporność na powolną propagację pęknięć. Próba z karbem","parameters":[{"name":"średnica od 63 mm","range":"do 315 mm"}],"technique":"Metoda z zastosowaniem ciśnienia hydrostatycznego","techniques":["Metoda z zastosowaniem ciśnienia hydrostatycznego"],"computed":[],"activity":"Odporność na powolną propagację pęknięć. Próba z karbem\nśrednica od 63 mm do 315 mm\nMetoda z zastosowaniem ciśnienia hydrostatycznego","reference":"PN-EN ISO 13479","norm_bases":["PN-EN ISO 13479"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury z poliolefin E Odporność na powolną propagację pęknięć. Próba z karbem\nśrednica od 63 mm do 315 mm\nMetoda z zastosowaniem ciśnienia hydrostatycznego PN-EN ISO 13479 Rury z poliolefin E Odpornosc na powolna propagacje pekniec. Proba z karbem\nsrednica od 63 mm do 315 mm\nMetoda z zastosowaniem cisnienia hydrostatycznego PN-EN ISO 13479","categories":["other"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Resistance to slow crack growth. Notch test","parameters_en":[{"name":"diameter from 63 mm","range":"do 315 mm"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Polyolefin pipes E Resistance to slow crack growth. Notch test Method using hydrostatic pressure Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. diameter from 63 mm PN-EN ISO 13479","technique_en":"Method using hydrostatic pressure","test_object_en":"Polyolefin pipes E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"静水压力法 塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 13479","lab_section_zh":"塑料实验室（GP-3）","technique_zh":"静水压力法"},{"_id":"6a7d75f9441eff5f15648885","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kształtki elektrooporowe z polietylenu E","methodology":"Odporność na odrywanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na odrywanie","reference":"ISO 13954 | ISO 13955 | ISO 13956","norm_bases":["ISO 13954","ISO 13955","ISO 13956"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kształtki elektrooporowe z polietylenu E Odporność na odrywanie ISO 13954 | ISO 13955 | ISO 13956 Ksztaltki elektrooporowe z polietylenu E Odpornosc na odrywanie ISO 13954 | ISO 13955 | ISO 13956","categories":["other"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Resistance to pull-off","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Polyethylene electrofusion fittings E Resistance to pull-off Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. ISO 13954 | ISO 13955 | ISO 13956","test_object_en":"Polyethylene electrofusion fittings E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 ISO 13954 | ISO 13955 | ISO 13956","lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f15648886","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kształtki elektrooporowe (siodłowe) z polietylenu E","methodology":"Odporność na uderzenia","parameters":[{"name":"Masa ciężarka:","range":"do 5 kg"},{"name":"Wysokość spadania","range":"do 2,5 m"}],"technique":"Metoda spadającego ciężarka","techniques":["Metoda spadającego ciężarka"],"computed":[],"activity":"Odporność na uderzenia\nZakres:\nMasa ciężarka: do 5 kg\nWysokość spadania do 2,5 m\nMetoda spadającego ciężarka","reference":"PN-EN 1716","norm_bases":["PN-EN 1716"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kształtki elektrooporowe (siodłowe) z polietylenu E Odporność na uderzenia\nZakres:\nMasa ciężarka: do 5 kg\nWysokość spadania do 2,5 m\nMetoda spadającego ciężarka PN-EN 1716 Ksztaltki elektrooporowe (siodlowe) z polietylenu E Odpornosc na uderzenia\nZakres:\nMasa ciezarka: do 5 kg\nWysokosc spadania do 2,5 m\nMetoda spadajacego ciezarka PN-EN 1716","categories":["other"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Impact resistance","parameters_en":[{"name":"Weight mass:","range":"do 5 kg"},{"name":"Drop height","range":"do 2,5 m"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Polyethylene electrofusion (saddle) fittings E Impact resistance Falling weight method Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Weight mass: Drop height PN-EN 1716","technique_en":"Falling weight method","test_object_en":"Polyethylene electrofusion (saddle) fittings E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"耐冲击性 落锤法 塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1716","lab_section_zh":"塑料实验室（GP-3）","methodology_zh":"耐冲击性","technique_zh":"落锤法"},{"_id":"6a7d75f9441eff5f15648887","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kształtki segmentowe (trójniki), Kurki z polietylenu, Złącza izolacyjne, Połączenia PE/Metal, Armatura z końcówkami z polietylenu, Przyłącza domowe do gazu E","methodology":"Odporność na działanie sił osiowych","parameters":[{"name":"Max siła","range":"320 kN"},{"name":"Próba rozciągania"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie sił osiowych\nZakres:\nMax siła 320 kN\nPróba rozciągania","reference":"Procedura P-23","norm_bases":["Procedura P-23"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kształtki segmentowe (trójniki), Kurki z polietylenu, Złącza izolacyjne, Połączenia PE/Metal, Armatura z końcówkami z polietylenu, Przyłącza domowe do gazu E Odporność na działanie sił osiowych\nZakres:\nMax siła 320 kN\nPróba rozciągania Procedura P-23 Ksztaltki segmentowe (trojniki), Kurki z polietylenu, Zlacza izolacyjne, Polaczenia PE/Metal, Armatura z koncowkami z polietylenu, Przylacza domowe do gazu E Odpornosc na dzialanie sil osiowych\nZakres:\nMax sila 320 kN\nProba rozciagania Procedura P-23","categories":["materials","construction"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Resistance to axial forces","parameters_en":[{"name":"Max force","range":"320 kN"},{"name":"Tensile test"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Segmented fittings (tees), Polyethylene valves, Insulating joints, PE/Metal transition joints, Fittings with polyethylene ends, Domestic gas service connections E Resistance to axial forces Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Max force Tensile test Procedura P-23","test_object_en":"Segmented fittings (tees), Polyethylene valves, Insulating joints, PE/Metal transition joints, Fittings with polyethylene ends, Domestic gas service connections E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 拉伸试验 Procedura P-23","lab_section_zh":"塑料实验室（GP-3）","parameters_zh":[{"name":"Max siła","range":"320 kN"},{"name":"拉伸试验"}]},{"_id":"6a7d75f9441eff5f15648888","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kurki z polietylenu, Złącza izolacyjne, Połączenia PE/Metal, Przyłącza domowe do gazu E","methodology":"Szczelność zewnętrzna","parameters":[],"technique":"Metoda badania powietrzem","techniques":["Metoda badania powietrzem"],"computed":[],"activity":"Szczelność zewnętrzna\nMetoda badania powietrzem","reference":"Procedura P-21","norm_bases":["Procedura P-21"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kurki z polietylenu, Złącza izolacyjne, Połączenia PE/Metal, Przyłącza domowe do gazu E Szczelność zewnętrzna\nMetoda badania powietrzem Procedura P-21 Kurki z polietylenu, Zlacza izolacyjne, Polaczenia PE/Metal, Przylacza domowe do gazu E Szczelnosc zewnetrzna\nMetoda badania powietrzem Procedura P-21","categories":["materials","environment","construction"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"External tightness","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Polyethylene valves, Insulating joints, PE/Metal transition joints, Domestic gas service connections E External tightness Air test method Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedura P-21","technique_en":"Air test method","test_object_en":"Polyethylene valves, Insulating joints, PE/Metal transition joints, Domestic gas service connections E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedura P-21","lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f15648889","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury i kształtki z tworzyw sztucznych, Systemy rur wielowarstwowych i złączek E","methodology":"Szczelność przy ciśnieniu wewnętrznym i zginaniu","parameters":[{"name":"ciśnienie","range":"(10 – 110) bar"},{"name":"średnica: DN","range":"(32 – 160 mm)"}],"technique":"Metoda z zastosowaniem ciśnienia wewnętrznego","techniques":["Metoda z zastosowaniem ciśnienia wewnętrznego"],"computed":[],"activity":"Szczelność przy ciśnieniu wewnętrznym i zginaniu\nZakres:\nciśnienie (10 – 110) bar\nśrednica: DN (32 – 160 mm)\nMetoda z zastosowaniem ciśnienia wewnętrznego","reference":"PN-EN ISO 3503","norm_bases":["PN-EN ISO 3503"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury i kształtki z tworzyw sztucznych, Systemy rur wielowarstwowych i złączek E Szczelność przy ciśnieniu wewnętrznym i zginaniu\nZakres:\nciśnienie (10 – 110) bar\nśrednica: DN (32 – 160 mm)\nMetoda z zastosowaniem ciśnienia wewnętrznego PN-EN ISO 3503 Rury i ksztaltki z tworzyw sztucznych, Systemy rur wielowarstwowych i zlaczek E Szczelnosc przy cisnieniu wewnetrznym i zginaniu\nZakres:\ncisnienie (10 – 110) bar\nsrednica: DN (32 – 160 mm)\nMetoda z zastosowaniem cisnienia wewnetrznego PN-EN ISO 3503","categories":["other"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Tightness under internal pressure and bending","parameters_en":[{"name":"pressure","range":"(10 – 110) bar"},{"name":"diameter: DN","range":"(32 – 160 mm)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Plastics pipes and fittings, Multilayer piping systems and fittings E Tightness under internal pressure and bending Method using internal pressure Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. pressure diameter: DN PN-EN ISO 3503","technique_en":"Method using internal pressure","test_object_en":"Plastics pipes and fittings, Multilayer piping systems and fittings E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 压力 PN-EN ISO 3503","parameters_zh":[{"name":"压力","range":"(10 – 110) bar"},{"name":"średnica: DN","range":"(32 – 160 mm)"}],"lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f1564888a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury i kształtki z tworzyw termoplastycznych, Systemy rur wielowarstwowych i złączek E","methodology":"Odporność na cykliczne zmiany ciśnienia","parameters":[{"name":"ciśnienie pmax","range":"do 55 bar"}],"technique":"Metoda z zastosowaniem cyklicznego działania ciśnienia","techniques":["Metoda z zastosowaniem cyklicznego działania ciśnienia"],"computed":[],"activity":"Odporność na cykliczne zmiany ciśnienia\nciśnienie pmax do 55 bar\nMetoda z zastosowaniem cyklicznego działania ciśnienia","reference":"PN-EN ISO 19892","norm_bases":["PN-EN ISO 19892"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury i kształtki z tworzyw termoplastycznych, Systemy rur wielowarstwowych i złączek E Odporność na cykliczne zmiany ciśnienia\nciśnienie pmax do 55 bar\nMetoda z zastosowaniem cyklicznego działania ciśnienia PN-EN ISO 19892 Rury i ksztaltki z tworzyw termoplastycznych, Systemy rur wielowarstwowych i zlaczek E Odpornosc na cykliczne zmiany cisnienia\ncisnienie pmax do 55 bar\nMetoda z zastosowaniem cyklicznego dzialania cisnienia PN-EN ISO 19892","categories":["other"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Resistance to cyclic pressure changes","parameters_en":[{"name":"pressure pmax","range":"do 55 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Thermoplastic pipes and fittings, Multilayer pipe and fitting systems E Resistance to cyclic pressure changes Method using cyclic pressure action Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. pressure pmax PN-EN ISO 19892","technique_en":"Method using cyclic pressure action","test_object_en":"Thermoplastic pipes and fittings, Multilayer pipe and fitting systems E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 19892","lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f1564888b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury i kształtki z tworzyw termoplastycznych, Systemy rur wielowarstwowych i złączek E","methodology":"Szczelność w warunkach podciśnienia","parameters":[{"name":"Ciśnienie","range":"do -0,8 bar"}],"technique":"Metoda z zastosowaniem podciśnienia","techniques":["Metoda z zastosowaniem podciśnienia"],"computed":[],"activity":"Szczelność w warunkach podciśnienia\nCiśnienie do -0,8 bar\nMetoda z zastosowaniem podciśnienia","reference":"PN-EN ISO 13056","norm_bases":["PN-EN ISO 13056"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury i kształtki z tworzyw termoplastycznych, Systemy rur wielowarstwowych i złączek E Szczelność w warunkach podciśnienia\nCiśnienie do -0,8 bar\nMetoda z zastosowaniem podciśnienia PN-EN ISO 13056 Rury i ksztaltki z tworzyw termoplastycznych, Systemy rur wielowarstwowych i zlaczek E Szczelnosc w warunkach podcisnienia\nCisnienie do -0,8 bar\nMetoda z zastosowaniem podcisnienia PN-EN ISO 13056","categories":["other"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Tightness under negative pressure conditions","parameters_en":[{"name":"Pressure","range":"do -0,8 bar"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Thermoplastic pipes and fittings, Multilayer pipe and fitting systems E Tightness under negative pressure conditions Method using vacuum Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Pressure PN-EN ISO 13056","technique_en":"Method using vacuum","test_object_en":"Thermoplastic pipes and fittings, Multilayer pipe and fitting systems E","parameters_zh":[{"name":"压力","range":"do -0,8 bar"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 压力 PN-EN ISO 13056","lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f1564888c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Polietylen, rury, kształtki i inne wyroby z polietylenu E","methodology":"Odporność na powolny wzrost pęknięć – moduł umocnienia (SHT)","parameters":[{"name":"siła","range":"do 500 N"},{"name":"Próba rozciągania"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na powolny wzrost pęknięć – moduł umocnienia (SHT)\nZakres:\nsiła do 500 N\nPróba rozciągania","reference":"ISO 18488","norm_bases":["ISO 18488"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Polietylen, rury, kształtki i inne wyroby z polietylenu E Odporność na powolny wzrost pęknięć – moduł umocnienia (SHT)\nZakres:\nsiła do 500 N\nPróba rozciągania ISO 18488 Polietylen, rury, ksztaltki i inne wyroby z polietylenu E Odpornosc na powolny wzrost pekniec – modul umocnienia (SHT)\nZakres:\nsila do 500 N\nProba rozciagania ISO 18488","categories":["other"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Resistance to slow crack growth – strain hardening modulus (SHT)","parameters_en":[{"name":"force","range":"do 500 N"},{"name":"Tensile test"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Polyethylene, pipes, fittings and other polyethylene products E Resistance to slow crack growth – strain hardening modulus (SHT) Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. force Tensile test ISO 18488","test_object_en":"Polyethylene, pipes, fittings and other polyethylene products E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 力 拉伸试验 ISO 18488","parameters_zh":[{"name":"力","range":"do 500 N"},{"name":"拉伸试验"}],"lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f1564888d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rury, kształtki i inne wyroby z polietylenu E","methodology":"Odporność na powolny wzrost pęknięć pod obciążeniem cyklicznym (CRB)","parameters":[{"name":"siła","range":"do 3 kN"},{"name":"Próba zmęczeniowa"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na powolny wzrost pęknięć pod obciążeniem cyklicznym (CRB)\nZakres:\nsiła do 3 kN\nPróba zmęczeniowa","reference":"ISO 18489","norm_bases":["ISO 18489"],"lab_section":"Laboratorium Tworzyw Sztucznych (GP-3)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Rury, kształtki i inne wyroby z polietylenu E Odporność na powolny wzrost pęknięć pod obciążeniem cyklicznym (CRB)\nZakres:\nsiła do 3 kN\nPróba zmęczeniowa ISO 18489 Rury, ksztaltki i inne wyroby z polietylenu E Odpornosc na powolny wzrost pekniec pod obciazeniem cyklicznym (CRB)\nZakres:\nsila do 3 kN\nProba zmeczeniowa ISO 18489","categories":["other"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Plastics Laboratory (GP-3)","methodology_en":"Resistance to slow crack growth under cyclic loading (CRB)","parameters_en":[{"name":"force","range":"do 3 kN"},{"name":"Fatigue test"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Polyethylene pipes, fittings and other products E Resistance to slow crack growth under cyclic loading (CRB) Plastics Laboratory (GP-3) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. force Fatigue test ISO 18489","test_object_en":"Polyethylene pipes, fittings and other products E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"塑料实验室（GP-3） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 力 ISO 18489","parameters_zh":[{"name":"力","range":"do 3 kN"},{"name":"Próba zmęczeniowa"}],"lab_section_zh":"塑料实验室（GP-3）"},{"_id":"6a7d75f9441eff5f1564888e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Urządzenia spalające paliwa gazowe używane do gotowania, ogrzewania, wytwarzania gorącej wody, chłodzenia, oświetlania , prania lub zmywania i w odpowiednich przypadkach mających temperaturę wody nie przekraczającą 105 °C palniki z wymuszonym ciągiem oraz urządzenia grzewcze przeznaczone do wyposażenia w takie palniki, (bez urządzeń przemysłowych), Urządzenia zabezpieczające, urządzenia kontroli lub urządzenia regulacyjne i podzespoły oddzielnie zbywane i zaprojektowane w celu przyłączenia do urządzenia spalającego paliwo gazowe lub po zmontowaniu tworzące takie urządzenie, (bez urządzeń przemysłowych)","methodology":"Cechy i właściwości do oceny bezpieczeństwa działania:","parameters":[{"name":"funkcjonalność armatury"},{"name":"sprawdzenie materiałów"},{"name":"stabilność mechaniczna"},{"name":"kondensacja"},{"name":"zagrożenie wybuchowe"},{"name":"penetracja wody"},{"name":"normalne i anormalne wahania energii zasilającej"},{"name":"ryzyko porażenia elektrycznego"},{"name":"wytrzymałość na ciśnienie"},{"name":"niezawodność urządzeń zabezpieczających, kontroli i regulacji"},{"name":"wzajemne oddziaływanie urządzeń sterujących i zabezpieczających"},{"name":"zabezpieczenia elementów ustawionych przez producenta"},{"name":"urządzenia kontrolne i nastawcze"},{"name":"wypływ niespalonego gazu"},{"name":"nieszczelności"},{"name":"akumulacja gazu w urządzeniu i w pomieszczeniu"},{"name":"bezpieczeństwo zapłonu"},{"name":"jakość i stabilność spalania"},{"name":"szczelność układu spalinowego"},{"name":"wypływ spalin do pomieszczenia w przypadku zakłóceń ciągu"},{"name":"temperatury nagrzania elementów Higieniczność elementów stykających się z wodą pitną i żywnością Racjonalne zużycie energii"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny bezpieczeństwa działania:\nZakres:\nfunkcjonalność armatury\nsprawdzenie materiałów\nstabilność mechaniczna\nkondensacja\nzagrożenie wybuchowe\npenetracja wody\nnormalne i anormalne wahania energii zasilającej\nryzyko porażenia elektrycznego\nwytrzymałość na ciśnienie\nniezawodność urządzeń zabezpieczających, kontroli i regulacji\nwzajemne oddziaływanie urządzeń sterujących i zabezpieczających\nzabezpieczenia elementów ustawionych przez producenta\nurządzenia kontrolne i nastawcze\nwypływ niespalonego gazu\nnieszczelności\nakumulacja gazu w urządzeniu i w pomieszczeniu\nbezpieczeństwo zapłonu\njakość i stabilność spalania\nszczelność układu spalinowego\nwypływ spalin do pomieszczenia w przypadku zakłóceń ciągu\ntemperatury nagrzania elementów Higieniczność elementów stykających się z wodą pitną i żywnością Racjonalne zużycie energii","reference":"PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002","norm_bases":["PN-EN 13278 :2003","PN-EN 203-1+A1 :2010","PN-EN 203-2-1 :2010","PN-EN 203-2-3 :2006","PN-EN 203-2-7:2007","PN-EN 26:2007","PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006","PN-EN 30-1-2:2002","PN-EN 30-2-1:2006","PN-EN 30-1-4 :2011","PN-EN 15502-1:2012","PN-EN 498:2002","PN-EN 89:2002+A3:2006+A4:2006","PN-EN 30-1-1+A2: 2010","PN-EN 483:2007","PN-EN 677:2007","PN-EN 625:2002"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia spalające paliwa gazowe używane do gotowania, ogrzewania, wytwarzania gorącej wody, chłodzenia, oświetlania , prania lub zmywania i w odpowiednich przypadkach mających temperaturę wody nie przekraczającą 105 °C palniki z wymuszonym ciągiem oraz urządzenia grzewcze przeznaczone do wyposażenia w takie palniki, (bez urządzeń przemysłowych), Urządzenia zabezpieczające, urządzenia kontroli lub urządzenia regulacyjne i podzespoły oddzielnie zbywane i zaprojektowane w celu przyłączenia do urządzenia spalającego paliwo gazowe lub po zmontowaniu tworzące takie urządzenie, (bez urządzeń przemysłowych) Cechy i właściwości do oceny bezpieczeństwa działania:\nZakres:\nfunkcjonalność armatury\nsprawdzenie materiałów\nstabilność mechaniczna\nkondensacja\nzagrożenie wybuchowe\npenetracja wody\nnormalne i anormalne wahania energii zasilającej\nryzyko porażenia elektrycznego\nwytrzymałość na ciśnienie\nniezawodność urządzeń zabezpieczających, kontroli i regulacji\nwzajemne oddziaływanie urządzeń sterujących i zabezpieczających\nzabezpieczenia elementów ustawionych przez producenta\nurządzenia kontrolne i nastawcze\nwypływ niespalonego gazu\nnieszczelności\nakumulacja gazu w urządzeniu i w pomieszczeniu\nbezpieczeństwo zapłonu\njakość i stabilność spalania\nszczelność układu spalinowego\nwypływ spalin do pomieszczenia w przypadku zakłóceń ciągu\ntemperatury nagrzania elementów Higieniczność elementów stykających się z wodą pitną i żywnością Racjonalne zużycie energii PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002 Urzadzenia spalajace paliwa gazowe uzywane do gotowania, ogrzewania, wytwarzania goracej wody, chlodzenia, oswietlania , prania lub zmywania i w odpowiednich przypadkach majacych temperature wody nie przekraczajaca 105 °C palniki z wymuszonym ciagiem oraz urzadzenia grzewcze przeznaczone do wyposazenia w takie palniki, (bez urzadzen przemyslowych), Urzadzenia zabezpieczajace, urzadzenia kontroli lub urzadzenia regulacyjne i podzespoly oddzielnie zbywane i zaprojektowane w celu przylaczenia do urzadzenia spalajacego paliwo gazowe lub po zmontowaniu tworzace takie urzadzenie, (bez urzadzen przemyslowych) Cechy i wlasciwosci do oceny bezpieczenstwa dzialania:\nZakres:\nfunkcjonalnosc armatury\nsprawdzenie materialow\nstabilnosc mechaniczna\nkondensacja\nzagrozenie wybuchowe\npenetracja wody\nnormalne i anormalne wahania energii zasilajacej\nryzyko porazenia elektrycznego\nwytrzymalosc na cisnienie\nniezawodnosc urzadzen zabezpieczajacych, kontroli i regulacji\nwzajemne oddzialywanie urzadzen sterujacych i zabezpieczajacych\nzabezpieczenia elementow ustawionych przez producenta\nurzadzenia kontrolne i nastawcze\nwyplyw niespalonego gazu\nnieszczelnosci\nakumulacja gazu w urzadzeniu i w pomieszczeniu\nbezpieczenstwo zaplonu\njakosc i stabilnosc spalania\nszczelnosc ukladu spalinowego\nwyplyw spalin do pomieszczenia w przypadku zaklocen ciagu\ntemperatury nagrzania elementow Higienicznosc elementow stykajacych sie z woda pitna i zywnoscia Racjonalne zuzycie energii PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002","categories":["materials","petro","water","food"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Characteristics and properties for the assessment of operational safety:","parameters_en":[{"name":"functionality of fittings"},{"name":"verification of materials"},{"name":"mechanical stability"},{"name":"condensation"},{"name":"explosion hazard"},{"name":"water penetration"},{"name":"normal and abnormal supply power fluctuations"},{"name":"risk of electric shock"},{"name":"pressure resistance"},{"name":"reliability of safety, control and regulating devices"},{"name":"interaction of control and safety devices"},{"name":"protection of components set by the manufacturer"},{"name":"control and setting devices"},{"name":"release of unburned gas"},{"name":"leaks"},{"name":"gas accumulation in the appliance and in the room"},{"name":"ignition safety"},{"name":"combustion quality and stability"},{"name":"tightness of the flue gas system"},{"name":"spillage of flue gases into the room in the event of draught disturbance"},{"name":"heating temperatures of components Hygiene of components in contact with drinking water and food Rational energy consumption"}],"search_en":"Appliances burning gaseous fuels used for cooking, heating, hot water production, refrigeration, lighting, washing or dish-washing and, where applicable, having a water temperature not exceeding 105 °C, forced draught burners and heating bodies to be equipped with such burners, (excluding industrial appliances), Safety devices, controlling devices or regulating devices and sub-assemblies marketed separately and designed to be incorporated into an appliance burning gaseous fuel or, when assembled, to constitute such an appliance, (excluding industrial appliances) Characteristics and properties for the assessment of operational safety: Gas and Heating Appliances Testing Laboratory (GU-1) functionality of fittings verification of materials mechanical stability condensation explosion hazard water penetration normal and abnormal supply power fluctuations risk of electric shock pressure resistance reliability of safety, control and regulating devices interaction of control and safety devices protection of components set by the manufacturer control and setting devices release of unburned gas leaks gas accumulation in the appliance and in the room ignition safety combustion quality and stability tightness of the flue gas system spillage of flue gases into the room in the event of draught disturbance heating temperatures of components Hygiene of components in contact with drinking water and food Rational energy consumption PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002","test_object_en":"Appliances burning gaseous fuels used for cooking, heating, hot water production, refrigeration, lighting, washing or dish-washing and, where applicable, having a water temperature not exceeding 105 °C, forced draught burners and heating bodies to be equipped with such burners, (excluding industrial appliances), Safety devices, controlling devices or regulating devices and sub-assemblies marketed separately and designed to be incorporated into an appliance burning gaseous fuel or, when assembled, to constitute such an appliance, (excluding industrial appliances)","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"用于动作安全性评定的特征与性能： 燃气与供暖器具检测实验室（GU-1） 阀件的功能性 材料检查 机械稳定性 冷凝 爆炸危险 水的渗入 供电能量的正常与非正常波动 触电风险 耐压强度 安全、控制与调节装置的可靠性 制造商预设元件的防护 控制与整定装置 未燃气体的泄出 泄漏 气体在设备内与房间内的积聚 点火安全性 燃烧质量与稳定性 排烟系统的密封性 抽力受扰时烟气向房间的泄出 元件的加热温度；与饮用水和食品接触元件的卫生性；能源的合理消耗 PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002","methodology_zh":"用于动作安全性评定的特征与性能：","parameters_zh":[{"name":"阀件的功能性"},{"name":"材料检查"},{"name":"机械稳定性"},{"name":"冷凝"},{"name":"爆炸危险"},{"name":"水的渗入"},{"name":"供电能量的正常与非正常波动"},{"name":"触电风险"},{"name":"耐压强度"},{"name":"安全、控制与调节装置的可靠性"},{"name":"wzajemne oddziaływanie urządzeń sterujących i zabezpieczających"},{"name":"制造商预设元件的防护"},{"name":"控制与整定装置"},{"name":"未燃气体的泄出"},{"name":"泄漏"},{"name":"气体在设备内与房间内的积聚"},{"name":"点火安全性"},{"name":"燃烧质量与稳定性"},{"name":"排烟系统的密封性"},{"name":"抽力受扰时烟气向房间的泄出"},{"name":"元件的加热温度；与饮用水和食品接触元件的卫生性；能源的合理消耗"}]},{"_id":"6a7d75f9441eff5f1564888f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002","norm_bases":["PN-EN 13278 :2003","PN-EN 203-1+A1 :2010","PN-EN 203-2-1 :2010","PN-EN 203-2-3 :2006","PN-EN 203-2-7:2007","PN-EN 26:2007","PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006","PN-EN 30-1-2:2002","PN-EN 30-2-1:2006","PN-EN 30-1-4 :2011","PN-EN 15502-1:2012","PN-EN 498:2002","PN-EN 89:2002+A3:2006+A4:2006","PN-EN 30-1-1+A2: 2010","PN-EN 483:2007","PN-EN 677:2007","PN-EN 625:2002"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe PARAMETRY PALIWA: PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002 Mieszkaniowe urzadzenia spalajace paliwo stale PARAMETRY PALIWA: PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002","categories":["petro"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FUEL PARAMETERS:","search_en":"Residential solid fuel burning appliances FUEL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃料参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 13278 :2003 | PN-EN 203-1+A1 :2010 | PN-EN 203-2-1 :2010 | PN-EN 203-2-3 :2006 | PN-EN 203-2-7:2007 | PN-EN 26:2007 | PN-EN 297:2002+A4:2007+A6:2006 +Ap1:2006+AC:2006 | PN-EN 30-1-2:2002 | PN-EN 30-2-1:2006 | PN-EN 30-1-4 :2011 | PN-EN 15502-1:2012 | PN-EN 498:2002 | PN-EN 89:2002+A3:2006+A4:2006 | PN-EN 30-1-1+A2: 2010 | PN-EN 483:2007 | PN-EN 677:2007 | PN-EN 625:2002","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"燃料参数："},{"_id":"6a7d75f9441eff5f15648890","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 – 20) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 – 20) kg","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"fuel mass","range":"(0,1 – 20) kg"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) fuel mass PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 燃料质量 PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"燃料质量","range":"(0,1 – 20) kg"}]},{"_id":"6a7d75f9441eff5f15648891","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FLUE GAS PARAMETERS:","search_en":"Residential solid fuel burning appliances FLUE GAS PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 烟气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"烟气参数："},{"_id":"6a7d75f9441eff5f15648892","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 600) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 600) °C"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(0 – 600) °C"}],"test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d75f9441eff5f15648893","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"ciśnienie","range":"(0,01 – 200) Pa;"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0,01 – 200) Pa;","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4; A.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4; A.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe ciśnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 Mieszkaniowe urzadzenia spalajace paliwo stale cisnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.4; A.4","categories":["petro"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(0,01 – 200) Pa;"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) pressure PN-EN 16510-1:2023-06 p. A.2.3.4; A.4","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 压力 PN-EN 16510-1:2023-06 p. A.2.3.4; A.4","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"压力","range":"(0,01 – 200) Pa;"}]},{"_id":"6a7d75f9441eff5f15648894","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"Stężenia dwutlenku węgla, tlenku węgla, tlenu","parameters":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"Emisja CO (z obliczeń)"}],"technique":"Metoda NDIR; Metoda: PMD - paramagnetyczna; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda: PMD - paramagnetyczna","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD - paramagnetyczna; Metoda elektrochemiczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD - paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-1:2023-06 p. A.4.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale Stezenia dwutlenku wegla, tlenku wegla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczen)\nMetoda NDIR; Metoda: PMD - paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-1:2023-06 p. A.4.4.2","categories":["petro","environment"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of carbon dioxide, carbon monoxide, oxygen","parameters_en":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO emission (calculated)"}],"search_en":"Residential solid fuel burning appliances Concentrations of carbon dioxide, carbon monoxide, oxygen NDIR method; Method: PMD - paramagnetic; Electrochemical method Gas and Heating Appliances Testing Laboratory (GU-1) CO2; CO; O2; O2; CO emission (calculated) PN-EN 16510-1:2023-06 p. A.4.4.2","technique_en":"NDIR method; Method: PMD - paramagnetic; Electrochemical method","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 二氧化碳、一氧化碳、氧浓度 燃气与供暖器具检测实验室（GU-1） CO 排放量（计算值） PN-EN 16510-1:2023-06 p. A.4.4.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO 排放量（计算值）"}],"methodology_zh":"二氧化碳、一氧化碳、氧浓度"},{"_id":"6a7d75f9441eff5f15648895","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.","parameters":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencja; Metoda FID","techniques":["Metoda chemiluminescencja","Metoda FID"],"computed":[],"activity":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E Mieszkaniowe urzadzenia spalajace paliwo stale Stezenia tlenku azotu, tlenkow azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczen)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E","categories":["petro","environment"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.","parameters_en":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 – 1288) mg org. C/m3 CO2 emission; NO, NO2, NOx, OGC (calculated)"}],"search_en":"Residential solid fuel burning appliances Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC. Chemiluminescence method; FID method Gas and Heating Appliances Testing Laboratory (GU-1) NO NOx OGC; (0,269 – 1288) mg org. C/m3 CO2 emission; NO, NO2, NOx, OGC (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","technique_en":"Chemiluminescence method; FID method","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。 化学发光法；FID 法 燃气与供暖器具检测实验室（GU-1） NO NOx PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","parameters_zh":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。","technique_zh":"化学发光法；FID 法"},{"_id":"6a7d75f9441eff5f15648896","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E Mieszkaniowe urzadzenia spalajace paliwo stale PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E","categories":["petro"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"AIR PARAMETERS:","search_en":"Residential solid fuel burning appliances AIR PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 空气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"空气参数："},{"_id":"6a7d75f9441eff5f15648897","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"temperatura","range":"(10 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 – 35) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(10 – 35) °C"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 – 35) °C"}],"test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d75f9441eff5f15648898","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"WATER PARAMETERS:","search_en":"Residential solid fuel burning appliances WATER PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 水参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"水参数："},{"_id":"6a7d75f9441eff5f15648899","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 100) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe temperatura (0 – 100) °C PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale temperatura (0 – 100) °C PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 100) °C"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(0 – 100) °C"}],"test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d75f9441eff5f1564889a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"strumień objętości :","range":"(0,24 – 12) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości : (0,24 – 12) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe strumień objętości : (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale strumien objetosci : (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"volume flow rate :","range":"(0,24 – 12) m3/h"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) volume flow rate : PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 体积流量： PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"体积流量：","range":"(0,24 – 12) m3/h"}]},{"_id":"6a7d75f9441eff5f1564889b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"HEAT BALANCE (calculated):","search_en":"Residential solid fuel burning appliances HEAT BALANCE (calculated): Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 热平衡（计算值）： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d75f9441eff5f1564889c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 – 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 – 60) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe moc cieplna doprowadzona z paliwem (3 – 60) kW PN-EN 16510-1:2023-06 p. A.6.2.2 Mieszkaniowe urzadzenia spalajace paliwo stale moc cieplna doprowadzona z paliwem (3 – 60) kW PN-EN 16510-1:2023-06 p. A.6.2.2","categories":["petro"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat input from fuel","range":"(3 – 60) kW"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) heat input from fuel PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 燃料输入热功率 PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"燃料输入热功率","range":"(3 – 60) kW"}]},{"_id":"6a7d75f9441eff5f1564889d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 – 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 – 40) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.6.2.1.2 Mieszkaniowe urzadzenia spalajace paliwo stale strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.6.2.1.2","categories":["petro"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"stack loss","range":"(5 – 40) %"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) stack loss PN-EN 16510-1:2023-06 p. A.6.2.1.2","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 排烟热损失 PN-EN 16510-1:2023-06 p. A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"排烟热损失","range":"(5 – 40) %"}]},{"_id":"6a7d75f9441eff5f1564889e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe straty niezupełnego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.3 Mieszkaniowe urzadzenia spalajace paliwo stale straty niezupelnego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.3","categories":["petro"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"losses due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) losses due to incomplete combustion PN-EN 16510-1:2023-06 p. A.6.2.1.3","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f1564889f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe strata niecałkowitego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.4 Mieszkaniowe urzadzenia spalajace paliwo stale strata niecalkowitego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.4","categories":["petro"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) loss due to incomplete combustion PN-EN 16510-1:2023-06 p. A.6.2.1.4","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f156488a0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 – 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 – 95) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe sprawność cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1 Mieszkaniowe urzadzenia spalajace paliwo stale sprawnosc cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1","categories":["petro"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal efficiency","range":"(20 – 95) %"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) thermal efficiency PN-EN 16510-1:2023-06 p. A.6.2.1","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 热效率 PN-EN 16510-1:2023-06 p. A.6.2.1","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"热效率","range":"(20 – 95) %"}]},{"_id":"6a7d75f9441eff5f156488a1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe łączna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2 Mieszkaniowe urzadzenia spalajace paliwo stale laczna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2","categories":["petro"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"total heat output","range":"(3 – 50) kW"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) total heat output PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 总热功率 PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"总热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f156488a2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe moc cieplna obiegu wodnego (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.3 Mieszkaniowe urzadzenia spalajace paliwo stale moc cieplna obiegu wodnego (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.3","categories":["petro"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output of the water circuit","range":"(3 – 50) kW"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) heat output of the water circuit PN-EN 16510-1:2023-06 p. A.6.2.3","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 水循环回路热功率 PN-EN 16510-1:2023-06 p. A.6.2.3","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"水循环回路热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f156488a3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4 Mieszkaniowe urzadzenia spalajace paliwo stale moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4","categories":["petro"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output to the room","range":"(3 – 50) kW"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) heat output to the room PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 向房间输出的热功率 PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f156488a4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(5 – 100) g/s"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy spalin (5 – 100) g/s","reference":"PN-EN 16510-1:2023-06 p. A.6.2.5","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe strumień masy spalin (5 – 100) g/s PN-EN 16510-1:2023-06 p. A.6.2.5 Mieszkaniowe urzadzenia spalajace paliwo stale strumien masy spalin (5 – 100) g/s PN-EN 16510-1:2023-06 p. A.6.2.5","categories":["petro"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"flue gas mass flow","range":"(5 – 100) g/s"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) flue gas mass flow PN-EN 16510-1:2023-06 p. A.6.2.5","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 烟气质量流量 PN-EN 16510-1:2023-06 p. A.6.2.5","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"烟气质量流量","range":"(5 – 100) g/s"}]},{"_id":"6a7d75f9441eff5f156488a5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"zawartość CO (O2=13 %)","range":"(0,001 – 0,5) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13 %) (0,001 – 0,5) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe zawartość CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale zawartosc CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"CO content (O2=13 %)","range":"(0,001 – 0,5) %"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) CO content (O2=13 %) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） CO 含量（O2=13 %） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"CO 含量（O2=13 %）","range":"(0,001 – 0,5) %"}]},{"_id":"6a7d75f9441eff5f156488a6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","search_en":"Residential solid fuel burning appliances TECHNICAL AND OPERATIONAL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 技术与运行参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"技术与运行参数："},{"_id":"6a7d75f9441eff5f156488a7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 – 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 – 200)"},{"name":"°C"},{"name":"temperatura uchwytów","range":"(0 – 300) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200)\n°C\ntemperatura uchwytów (0 – 300) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200)\n°C\ntemperatura uchwytów (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10 Mieszkaniowe urzadzenia spalajace paliwo stale Zakres:\ntemperatura naroznika pomiarowego i podloza (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200)\n°C\ntemperatura uchwytow (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10","categories":["petro"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 – 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 – 200)"},{"name":"°C"},{"name":"temperature of handles","range":"(0 – 300) °C"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) temperature of the measuring corner and the floor temperature of the fuel hopper °C temperature of handles PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 – 200) °C"},{"name":"燃料储斗温度","range":"(0 – 200)"},{"name":"°C"},{"name":"手柄温度","range":"(0 – 300) °C"}]},{"_id":"6a7d75f9441eff5f156488a8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 – 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 – 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe szczelność przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 Mieszkaniowe urzadzenia spalajace paliwo stale szczelnosc przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6","categories":["petro"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness of the water space","range":"(0,1 – 0,6) MPa"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"水腔密封性","range":"(0,1 – 0,6) MPa"}]},{"_id":"6a7d75f9441eff5f156488a9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 – 120) °C"},{"name":"ciśnienie wody","range":"(0,1 – 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 Mieszkaniowe urzadzenia spalajace paliwo stale Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 – 120) °C\ncisnienie wody (0,1 – 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.6","categories":["petro","water"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 – 120) °C"},{"name":"water pressure","range":"(0,1 – 0,3) MPa"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p. A.4.10.6","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p. A.4.10.6","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"出水热保护 水温","range":"(0 – 120) °C"},{"name":"水压","range":"(0,1 – 0,3) MPa"}]},{"_id":"6a7d75f9441eff5f156488aa","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"szczelność","range":"(0,016 – 2,6) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (0,016 – 2,6) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.11.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.11.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe szczelność (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2 Mieszkaniowe urzadzenia spalajace paliwo stale szczelnosc (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2","categories":["petro"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness","range":"(0,016 – 2,6) m3/h"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) tightness PN-EN 16510-1:2023-06 p. A.4.11.2","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 密封性 PN-EN 16510-1:2023-06 p. A.4.11.2","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"密封性","range":"(0,016 – 2,6) m3/h"}]},{"_id":"6a7d75f9441eff5f156488ab","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p. 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p. 5.9.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p. 5.9.1 Mieszkaniowe urzadzenia spalajace paliwo stale szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p. 5.9.1","categories":["petro"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p. 5.9.1","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p. 5.9.1","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d75f9441eff5f156488ac","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"pomiar zużycia energii elektrycznej (1 – 1500) W, metoda: przetworników mocy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"pomiar zużycia energii elektrycznej (1 – 1500) W, metoda: przetworników mocy","reference":"PN-EN 16510-1:2023-06 p. 6.11","norm_bases":["PN-EN 16510-1:2023-06 p. 6.11"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe pomiar zużycia energii elektrycznej (1 – 1500) W, metoda: przetworników mocy PN-EN 16510-1:2023-06 p. 6.11 Mieszkaniowe urzadzenia spalajace paliwo stale pomiar zuzycia energii elektrycznej (1 – 1500) W, metoda: przetwornikow mocy PN-EN 16510-1:2023-06 p. 6.11","categories":["petro"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"measurement of electrical energy consumption (1 – 1500) W, method: power transducers","search_en":"Residential solid fuel burning appliances measurement of electrical energy consumption (1 – 1500) W, method: power transducers Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. 6.11","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. 6.11","test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d75f9441eff5f156488ad","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p. A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p. A.4.10.4 Mieszkaniowe urzadzenia spalajace paliwo stale proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p. A.4.10.4","categories":["petro"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature safety test"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) temperature safety test PN-EN 16510-1:2023-06 p. A.4.10.4","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 温度安全性试验 PN-EN 16510-1:2023-06 p. A.4.10.4","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d75f9441eff5f156488ae","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p. A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p. A.4.10.5 Mieszkaniowe urzadzenia spalajace paliwo stale proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p. A.4.10.5","categories":["petro"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"safety test under natural draught"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) safety test under natural draught PN-EN 16510-1:2023-06 p. A.4.10.5","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p. A.4.10.5","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d75f9441eff5f156488af","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"działanie ogranicznika temperatury bezpieczeństwa","range":"(0 – 110) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"działanie ogranicznika temperatury bezpieczeństwa (0 – 110) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe działanie ogranicznika temperatury bezpieczeństwa (0 – 110) °C PN-EN 16510-1:2023-06 p. A.4.10.7 Mieszkaniowe urzadzenia spalajace paliwo stale dzialanie ogranicznika temperatury bezpieczenstwa (0 – 110) °C PN-EN 16510-1:2023-06 p. A.4.10.7","categories":["petro"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"operation of the safety temperature limiter","range":"(0 – 110) °C"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) operation of the safety temperature limiter PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 安全温度限制器的动作 PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"安全温度限制器的动作","range":"(0 – 110) °C"}]},{"_id":"6a7d75f9441eff5f156488b0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"zanik zasilania elektrycznego","range":"(0 – 110) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"zanik zasilania elektrycznego (0 – 110) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe zanik zasilania elektrycznego (0 – 110) °C PN-EN 16510-1:2023-06 p. A.4.10.7 Mieszkaniowe urzadzenia spalajace paliwo stale zanik zasilania elektrycznego (0 – 110) °C PN-EN 16510-1:2023-06 p. A.4.10.7","categories":["petro"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss of electrical power supply","range":"(0 – 110) °C"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) loss of electrical power supply PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 供电中断 PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"供电中断","range":"(0 – 110) °C"}]},{"_id":"6a7d75f9441eff5f156488b1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"zanik odbioru ciepła","range":"(0 – 110) °C,"},{"name":"(0 – 5) %CO"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzanik odbioru ciepła (0 – 110) °C,\n(0 – 5) %CO","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe Zakres:\nzanik odbioru ciepła (0 – 110) °C,\n(0 – 5) %CO PN-EN 16510-1:2023-06 p. A.4.10.7 Mieszkaniowe urzadzenia spalajace paliwo stale Zakres:\nzanik odbioru ciepla (0 – 110) °C,\n(0 – 5) %CO PN-EN 16510-1:2023-06 p. A.4.10.7","categories":["petro"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss of heat dissipation","range":"(0 – 110) °C,"},{"name":"(0 – 5) %CO"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) loss of heat dissipation (0 – 5) %CO PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_zh":"民用固体燃料燃烧器具"},{"_id":"6a7d75f9441eff5f156488b2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"efektywność (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe efektywność (z obliczeń) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6 Mieszkaniowe urzadzenia spalajace paliwo stale efektywnosc (z obliczen) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6","categories":["petro"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"efficiency (calculated)"}],"search_en":"Residential solid fuel burning appliances Gas and Heating Appliances Testing Laboratory (GU-1) efficiency (calculated) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 燃气与供暖器具检测实验室（GU-1） 效率（由计算得出） PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6","test_object_zh":"民用固体燃料燃烧器具","parameters_zh":[{"name":"效率（由计算得出）"}]},{"_id":"6a7d75f9441eff5f156488b3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,003 – 1) g/m3"}],"technique":"Metoda: grawimetryczna","techniques":["Metoda: grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna","reference":"PN-EN 16510-1:2023-06 Załącznik F","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Załącznik F Mieszkaniowe urzadzenia spalajace paliwo stale Stezenie pylow w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Zalacznik F","categories":["petro"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,003 – 1) g/m3"}],"search_en":"Residential solid fuel burning appliances Dust concentration in flue gases Method: gravimetric Gas and Heating Appliances Testing Laboratory (GU-1) Range PN-EN 16510-1:2023-06 Załącznik F","technique_en":"Method: gravimetric","test_object_en":"Residential solid fuel burning appliances","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","parameters_zh":[{"name":"范围","range":"(0,003 – 1) g/m3"}],"search_zh":"民用固体燃料燃烧器具 烟气中粉尘浓度 方法：重量法 燃气与供暖器具检测实验室（GU-1） 范围 PN-EN 16510-1:2023-06 Załącznik F","test_object_zh":"民用固体燃料燃烧器具","methodology_zh":"烟气中粉尘浓度","technique_zh":"方法：重量法"},{"_id":"6a7d75f9441eff5f156488b4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 Załącznik F","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Załącznik F Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Zalacznik F","categories":["petro"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FUEL PARAMETERS:","search_en":"Residential solid fuel burning appliances - Roomheaters FUEL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 Załącznik F","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃料参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 Załącznik F","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"燃料参数："},{"_id":"6a7d75f9441eff5f156488b5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 – 20) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 – 20) kg","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"fuel mass","range":"(0,1 – 20) kg"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) fuel mass PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 燃料质量 PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"燃料质量","range":"(0,1 – 20) kg"}]},{"_id":"6a7d75f9441eff5f156488b6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FLUE GAS PARAMETERS:","search_en":"Residential solid fuel burning appliances - Roomheaters FLUE GAS PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 烟气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"烟气参数："},{"_id":"6a7d75f9441eff5f156488b7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 600) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-1:2023-06 p.4.7.2, 4.7.3, 4.7.8 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3","PN-EN 16510-2-1:2023-06 p.4.7.2, 4.7.3, 4.7.8 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-1:2023-06 p.4.7.2, 4.7.3, 4.7.8 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-1:2023-06 p.4.7.2, 4.7.3, 4.7.8 „N“","categories":["petro"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 600) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-1:2023-06 p.4.7.2, 4.7.3, 4.7.8 „N“","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-1:2023-06 p.4.7.2, 4.7.3, 4.7.8 „N“","parameters_zh":[{"name":"温度","range":"(0 – 600) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d75f9441eff5f156488b8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"ciśnienie","range":"(0,01 – 200) Pa;"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0,01 – 200) Pa;","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4; A.4","PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe ciśnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe cisnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“","categories":["petro"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(0,01 – 200) Pa;"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“","parameters_zh":[{"name":"压力","range":"(0,01 – 200) Pa;"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d75f9441eff5f156488b9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"Stężenia dwutlenku węgla, tlenku węgla, tlenu","parameters":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"Emisja CO (z obliczeń)"}],"technique":"Metoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda: PMD- paramagnetyczna","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2","PN-EN 16510-2-1:2023-06 p. 4.3 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe Stezenia dwutlenku wegla, tlenku wegla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczen)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“","categories":["petro","environment"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of carbon dioxide, carbon monoxide, oxygen","parameters_en":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO emission (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Concentrations of carbon dioxide, carbon monoxide, oxygen NDIR method; Method: PMD- paramagnetic; Electrochemical method Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2; CO; O2; O2; CO emission (calculated) PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“","technique_en":"NDIR method; Method: PMD- paramagnetic; Electrochemical method","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 二氧化碳、一氧化碳、氧浓度 NDIR 法；PMD 顺磁法；电化学法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 CO 排放量（计算值） PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO 排放量（计算值）"}],"methodology_zh":"二氧化碳、一氧化碳、氧浓度","technique_zh":"NDIR 法；PMD 顺磁法；电化学法"},{"_id":"6a7d75f9441eff5f156488ba","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.","parameters":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencja; Metoda FID","techniques":["Metoda chemiluminescencja","Metoda FID"],"computed":[],"activity":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID","reference":"PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","norm_bases":["PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe Stezenia tlenku azotu, tlenkow azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczen)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","categories":["petro","environment"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.","parameters_en":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 –1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC. Chemiluminescence method; FID method Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO NOx OGC; (0,269 –1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated) PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","technique_en":"Chemiluminescence method; FID method","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。 化学发光法；FID 法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 NO NOx OGC；(0,269 –1288) mg 有机 C/m3；CO2、NO、NO2、NOx、OGC 排放（由计算得出） PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","parameters_zh":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC；(0,269 –1288) mg 有机 C/m3；CO2、NO、NO2、NOx、OGC 排放（由计算得出）"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。","technique_zh":"化学发光法；FID 法"},{"_id":"6a7d75f9441eff5f156488bb","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","norm_bases":["PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe PARAMETRY POWIETRZA: PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe PARAMETRY POWIETRZA: PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","categories":["petro"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters AIR PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 空气参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023- 06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"空气参数："},{"_id":"6a7d75f9441eff5f156488bc","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"temperatura","range":"(10 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 – 35) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(10 – 35) °C"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 – 35) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d75f9441eff5f156488bd","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"WATER PARAMETERS:","search_en":"Residential solid fuel burning appliances - Roomheaters WATER PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 水参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"水参数："},{"_id":"6a7d75f9441eff5f156488be","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 100) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe temperatura (0 – 100) °C PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe temperatura (0 – 100) °C PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 100) °C"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(0 – 100) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d75f9441eff5f156488bf","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"strumień objętości :","range":"(0,24 – 12) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości : (0,24 – 12) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe strumień objętości : (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe strumien objetosci : (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"volume flow rate :","range":"(0,24 – 12) m3/h"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) volume flow rate : PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 体积流量： PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"体积流量：","range":"(0,24 – 12) m3/h"}]},{"_id":"6a7d75f9441eff5f156488c0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"HEAT BALANCE (calculated):","search_en":"Residential solid fuel burning appliances - Roomheaters HEAT BALANCE (calculated): Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 热平衡（计算值）： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d75f9441eff5f156488c1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 – 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 – 60) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe moc cieplna doprowadzona z paliwem (3 – 60) kW PN-EN 16510-1:2023-06 p. A.6.2.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe moc cieplna doprowadzona z paliwem (3 – 60) kW PN-EN 16510-1:2023-06 p. A.6.2.2","categories":["petro"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat input from fuel","range":"(3 – 60) kW"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) heat input from fuel PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 燃料输入热功率 PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"燃料输入热功率","range":"(3 – 60) kW"}]},{"_id":"6a7d75f9441eff5f156488c2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 – 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 – 40) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.6.2.1.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.6.2.1.2","categories":["petro"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"stack loss","range":"(5 – 40) %"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) stack loss PN-EN 16510-1:2023-06 p. A.6.2.1.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 排烟热损失 PN-EN 16510-1:2023-06 p. A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"排烟热损失","range":"(5 – 40) %"}]},{"_id":"6a7d75f9441eff5f156488c3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe straty niezupełnego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe straty niezupelnego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.3","categories":["petro"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"losses due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) losses due to incomplete combustion PN-EN 16510-1:2023-06 p. A.6.2.1.3","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f156488c4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe strata niecałkowitego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe strata niecalkowitego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.4","categories":["petro"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) loss due to incomplete combustion PN-EN 16510-1:2023-06 p. A.6.2.1.4","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f156488c5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 – 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 – 95) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1","PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe sprawność cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe sprawnosc cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N”","categories":["petro"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal efficiency","range":"(20 – 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"热效率","range":"(20 – 95) %"}]},{"_id":"6a7d75f9441eff5f156488c6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.2","PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe łączna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe laczna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N”","categories":["petro"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"total heat output","range":"(3 – 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. total heat output PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总热功率 PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"总热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f156488c7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(3 – 50)"},{"name":"kW"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nmoc cieplna obiegu wodnego (3 – 50)\nkW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.3","PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe Zakres:\nmoc cieplna obiegu wodnego (3 – 50)\nkW PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe Zakres:\nmoc cieplna obiegu wodnego (3 – 50)\nkW PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N”","categories":["petro"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output of the water circuit","range":"(3 – 50)"},{"name":"kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit kW PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"水循环回路热功率","range":"(3 – 50)"},{"name":"kW"}]},{"_id":"6a7d75f9441eff5f156488c8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4","categories":["petro"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output to the room","range":"(3 – 50) kW"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) heat output to the room PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 向房间输出的热功率 PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f156488c9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(5 – 100) g/s"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy spalin (5 – 100) g/s","reference":"PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.5","PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe strumień masy spalin (5 – 100) g/s PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe strumien masy spalin (5 – 100) g/s PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","categories":["petro"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"flue gas mass flow","range":"(5 – 100) g/s"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"烟气质量流量","range":"(5 – 100) g/s"}]},{"_id":"6a7d75f9441eff5f156488ca","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"zawartość CO (O2=13 %)","range":"(0,001 – 0,5) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13 %) (0,001 – 0,5) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe zawartość CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe zawartosc CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"CO content (O2=13 %)","range":"(0,001 – 0,5) %"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) CO content (O2=13 %) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） CO 含量（O2=13 %） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"CO 含量（O2=13 %）","range":"(0,001 – 0,5) %"}]},{"_id":"6a7d75f9441eff5f156488cb","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","search_en":"Residential solid fuel burning appliances - Roomheaters TECHNICAL AND OPERATIONAL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 技术与运行参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"技术与运行参数："},{"_id":"6a7d75f9441eff5f156488cc","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 – 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 – 200)"},{"name":"°C"},{"name":"temperatura uchwytów","range":"(0 – 300) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200)\n°C\ntemperatura uchwytów (0 – 300) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10 | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10","PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200)\n°C\ntemperatura uchwytów (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10 | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe Zakres:\ntemperatura naroznika pomiarowego i podloza (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200)\n°C\ntemperatura uchwytow (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10 | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“","categories":["petro"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 – 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 – 200)"},{"name":"°C"},{"name":"temperature of handles","range":"(0 – 300) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper °C temperature of handles PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10 | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p. A.4.7; A.4.8; A.4.9; A.4.10 | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 – 200) °C"},{"name":"燃料储斗温度","range":"(0 – 200)"},{"name":"°C"},{"name":"手柄温度","range":"(0 – 300) °C"}]},{"_id":"6a7d75f9441eff5f156488cd","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 – 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 – 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6","PN-EN 16510-2-1:2023-06 p. 5.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe szczelność przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe szczelnosc przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N”","categories":["petro"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness of the water space","range":"(0,1 – 0,6) MPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"水腔密封性","range":"(0,1 – 0,6) MPa"}]},{"_id":"6a7d75f9441eff5f156488ce","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 – 120) °C"},{"name":"ciśnienie wody","range":"(0,1 – 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.7 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 – 120) °C\ncisnienie wody (0,1 – 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.7","categories":["petro","water"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 – 120) °C"},{"name":"water pressure","range":"(0,1 – 0,3) MPa"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"出水热保护 水温","range":"(0 – 120) °C"},{"name":"水压","range":"(0,1 – 0,3) MPa"}]},{"_id":"6a7d75f9441eff5f156488cf","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"szczelność","range":"(0,016 – 2,6) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (0,016 – 2,6) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.11.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.11.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe szczelność (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe szczelnosc (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2","categories":["petro"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness","range":"(0,016 – 2,6) m3/h"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) tightness PN-EN 16510-1:2023-06 p. A.4.11.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 密封性 PN-EN 16510-1:2023-06 p. A.4.11.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"密封性","range":"(0,016 – 2,6) m3/h"}]},{"_id":"6a7d75f9441eff5f156488d0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p. 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p. 5.9.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p. 5.9.1 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p. 5.9.1","categories":["petro"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p. 5.9.1","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p. 5.9.1","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d75f9441eff5f156488d1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"pomiar zużycia energii elektrycznej (1 – 1500) W, metoda: przetworników mocy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"pomiar zużycia energii elektrycznej (1 – 1500) W, metoda: przetworników mocy","reference":"PN-EN 16510-1:2023-06 p. 6.11","norm_bases":["PN-EN 16510-1:2023-06 p. 6.11"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe pomiar zużycia energii elektrycznej (1 – 1500) W, metoda: przetworników mocy PN-EN 16510-1:2023-06 p. 6.11 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe pomiar zuzycia energii elektrycznej (1 – 1500) W, metoda: przetwornikow mocy PN-EN 16510-1:2023-06 p. 6.11","categories":["petro"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"measurement of electrical energy consumption (1 – 1500) W, method: power transducers","search_en":"Residential solid fuel burning appliances - Roomheaters measurement of electrical energy consumption (1 – 1500) W, method: power transducers Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. 6.11","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. 6.11","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器"},{"_id":"6a7d75f9441eff5f156488d2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p A.4.10.4","categories":["petro"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature safety test"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) temperature safety test PN-EN 16510-1:2023-06 p A.4.10.4","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 温度安全性试验 PN-EN 16510-1:2023-06 p A.4.10.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d75f9441eff5f156488d3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p A.4.10.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p A.4.10.5","categories":["petro"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"safety test under natural draught"}],"search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) safety test under natural draught PN-EN 16510-1:2023-06 p A.4.10.5","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p A.4.10.5","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d75f9441eff5f156488d4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"},{"name":"sezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)"},{"name":"wskaźnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)\nwskaźnik efektywności energetycznej EEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p . A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N”","norm_bases":["PN-EN 16510-1:2023-06 p . A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)\nwskaźnik efektywności energetycznej EEI (z obliczeń) PN-EN 16510-1:2023-06 p . A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe Zakres:\nefektywnosc (z obliczen)\nsezonowa efektywnosc energetyczna ogrzewania pomieszczen (z obliczen)\nwskaznik efektywnosci energetycznej EEI (z obliczen) PN-EN 16510-1:2023-06 p . A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N”","categories":["petro"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"efficiency (calculated)"},{"name":"seasonal space heating energy efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated) seasonal space heating energy efficiency (calculated) energy efficiency index EEI (calculated) PN-EN 16510-1:2023-06 p . A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 效率（由计算得出） 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） PN-EN 16510-1:2023-06 p . A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","parameters_zh":[{"name":"效率（由计算得出）"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}]},{"_id":"6a7d75f9441eff5f156488d5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,003 – 1) g/m3"}],"technique":"Metoda: grawimetryczna","techniques":["Metoda: grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna","reference":"PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F","PN-EN 16510-2-1:2023-06 p. 4.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe Stezenie pylow w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Zalacznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”","categories":["petro"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,003 – 1) g/m3"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters Dust concentration in flue gases Method: gravimetric Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”","technique_en":"Method: gravimetric","test_object_en":"Residential solid fuel burning appliances - Roomheaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","parameters_zh":[{"name":"范围","range":"(0,003 – 1) g/m3"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器 烟气中粉尘浓度 方法：重量法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器","methodology_zh":"烟气中粉尘浓度","technique_zh":"方法：重量法"},{"_id":"6a7d75f9441eff5f156488d6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F","PN-EN 16510-2-1:2023-06 p. 4.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Zalacznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”","categories":["petro"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires FUEL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃料参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"燃料参数："},{"_id":"6a7d75f9441eff5f156488d7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 – 20) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 – 20) kg","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"fuel mass","range":"(0,1 – 20) kg"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) fuel mass PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 燃料质量 PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"燃料质量","range":"(0,1 – 20) kg"}]},{"_id":"6a7d75f9441eff5f156488d8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FLUE GAS PARAMETERS:","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires FLUE GAS PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 烟气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"烟气参数："},{"_id":"6a7d75f9441eff5f156488d9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 600) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3","PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N”","categories":["petro"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 600) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N”","parameters_zh":[{"name":"温度","range":"(0 – 600) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d75f9441eff5f156488da","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"ciśnienie","range":"(0,01 – 200) Pa;"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0,01 – 200) Pa;","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4; A.4","PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem ciśnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem cisnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5 „N”","categories":["petro"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(0,01 – 200) Pa;"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5 „N”","parameters_zh":[{"name":"压力","range":"(0,01 – 200) Pa;"}],"test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d75f9441eff5f156488db","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"Stężenia dwutlenku węgla, tlenku węgla, tlenu","parameters":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"Emisja CO (z obliczeń)"}],"technique":"Metoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda: PMD- paramagnetyczna","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2","PN-EN 16510-2-2:2023-06 p. 4.2 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem Stezenia dwutlenku wegla, tlenku wegla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczen)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“","categories":["petro","environment"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of carbon dioxide, carbon monoxide, oxygen","parameters_en":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO emission (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Concentrations of carbon dioxide, carbon monoxide, oxygen NDIR method; Method: PMD- paramagnetic; Electrochemical method Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2; CO; O2; O2; CO emission (calculated) PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“","technique_en":"NDIR method; Method: PMD- paramagnetic; Electrochemical method","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 二氧化碳、一氧化碳、氧浓度 NDIR 法；PMD 顺磁法；电化学法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 CO 排放量（计算值） PN-EN 16510-1:2023-06 p. A.4.4.2 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO 排放量（计算值）"}],"methodology_zh":"二氧化碳、一氧化碳、氧浓度","technique_zh":"NDIR 法；PMD 顺磁法；电化学法"},{"_id":"6a7d75f9441eff5f156488dc","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.","parameters":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencja; Metoda FID","techniques":["Metoda chemiluminescencja","Metoda FID"],"computed":[],"activity":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem Stezenia tlenku azotu, tlenkow azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczen)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","categories":["petro","environment"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.","parameters_en":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 – 1288) mg org. C/m3 CO2 emission; NO, NO2, NOx, OGC (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC. Chemiluminescence method; FID method Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO NOx OGC; (0,269 – 1288) mg org. C/m3 CO2 emission; NO, NO2, NOx, OGC (calculated) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","technique_en":"Chemiluminescence method; FID method","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。 化学发光法；FID 法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 NO NOx PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","parameters_zh":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 – 1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。","technique_zh":"化学发光法；FID 法"},{"_id":"6a7d75f9441eff5f156488dd","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“ Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","categories":["petro"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires AIR PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 空气参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"空气参数："},{"_id":"6a7d75f9441eff5f156488de","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"temperatura","range":"(10 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 – 35) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(10 – 35) °C"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 – 35) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d75f9441eff5f156488df","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"WATER PARAMETERS:","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires WATER PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 水参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"水参数："},{"_id":"6a7d75f9441eff5f156488e0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 100) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem temperatura (0 – 100) °C PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem temperatura (0 – 100) °C PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 100) °C"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(0 – 100) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式"},{"_id":"6a7d75f9441eff5f156488e1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"strumień objętości :","range":"(0,24 – 12) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości : (0,24 – 12) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem strumień objętości : (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem strumien objetosci : (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"volume flow rate :","range":"(0,24 – 12) m3/h"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) volume flow rate : PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 体积流量： PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"体积流量：","range":"(0,24 – 12) m3/h"}]},{"_id":"6a7d75f9441eff5f156488e2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"HEAT BALANCE (calculated):","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires HEAT BALANCE (calculated): Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 热平衡（计算值）： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d75f9441eff5f156488e3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 – 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 – 60) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem moc cieplna doprowadzona z paliwem (3 – 60) kW PN-EN 16510-1:2023-06 p. A.6.2.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem moc cieplna doprowadzona z paliwem (3 – 60) kW PN-EN 16510-1:2023-06 p. A.6.2.2","categories":["petro"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat input from fuel","range":"(3 – 60) kW"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) heat input from fuel PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 燃料输入热功率 PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"燃料输入热功率","range":"(3 – 60) kW"}]},{"_id":"6a7d75f9441eff5f156488e4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 – 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 – 40) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.6.2.1.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.6.2.1.2","categories":["petro"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"stack loss","range":"(5 – 40) %"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) stack loss PN-EN 16510-1:2023-06 p. A.6.2.1.2","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 排烟热损失 PN-EN 16510-1:2023-06 p. A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"排烟热损失","range":"(5 – 40) %"}]},{"_id":"6a7d75f9441eff5f156488e5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem straty niezupełnego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem straty niezupelnego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.3","categories":["petro"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"losses due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) losses due to incomplete combustion PN-EN 16510-1:2023-06 p. A.6.2.1.3","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f156488e6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem strata niecałkowitego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem strata niecalkowitego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.4","categories":["petro"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) loss due to incomplete combustion PN-EN 16510-1:2023-06 p. A.6.2.1.4","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f156488e7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 – 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 – 95) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1","PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem sprawność cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem sprawnosc cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N”","categories":["petro"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal efficiency","range":"(20 – 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"热效率","range":"(20 – 95) %"}]},{"_id":"6a7d75f9441eff5f156488e8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.2","PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem łączna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem laczna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N”","categories":["petro"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"total heat output","range":"(3 – 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. total heat output PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总热功率 PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"总热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f156488e9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.3","PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem moc cieplna obiegu wodnego (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem moc cieplna obiegu wodnego (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N”","categories":["petro"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output of the water circuit","range":"(3 – 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"水循环回路热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f156488ea","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4","categories":["petro"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output to the room","range":"(3 – 50) kW"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) heat output to the room PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 向房间输出的热功率 PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f156488eb","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(5 – 100) g/s"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy spalin (5 – 100) g/s","reference":"PN-EN 16510-1:2018-08 p. A.6.2.5 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N”","norm_bases":["PN-EN 16510-1:2018-08 p. A.6.2.5","PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem strumień masy spalin (5 – 100) g/s PN-EN 16510-1:2018-08 p. A.6.2.5 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem strumien masy spalin (5 – 100) g/s PN-EN 16510-1:2018-08 p. A.6.2.5 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N”","categories":["petro"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"flue gas mass flow","range":"(5 – 100) g/s"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow PN-EN 16510-1:2018-08 p. A.6.2.5 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 PN-EN 16510-1:2018-08 p. A.6.2.5 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"烟气质量流量","range":"(5 – 100) g/s"}]},{"_id":"6a7d75f9441eff5f156488ec","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"zawartość CO (O2=13 %)","range":"(0,001 – 0,5) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13 %) (0,001 – 0,5) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem zawartość CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem zawartosc CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"CO content (O2=13 %)","range":"(0,001 – 0,5) %"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) CO content (O2=13 %) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） CO 含量（O2=13 %） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"CO 含量（O2=13 %）","range":"(0,001 – 0,5) %"}]},{"_id":"6a7d75f9441eff5f156488ed","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires TECHNICAL AND OPERATIONAL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 技术与运行参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"技术与运行参数："},{"_id":"6a7d75f9441eff5f156488ee","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 – 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 – 200) °C"},{"name":"temperatura uchwytów","range":"(0 – 300) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 300) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.7; A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.7; A.4.8, A.4.9, A.4.10","PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7; A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem Zakres:\ntemperatura naroznika pomiarowego i podloza (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytow (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7; A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N”","categories":["petro"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 – 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 – 200) °C"},{"name":"temperature of handles","range":"(0 – 300) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 16510-1:2023-06 p. A.4.7; A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p. A.4.7; A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 – 200) °C"},{"name":"燃料储斗温度","range":"(0 – 200) °C"},{"name":"手柄温度","range":"(0 – 300) °C"}]},{"_id":"6a7d75f9441eff5f156488ef","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 – 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 – 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6","PN-EN 16510-2-2:2023-06 p. 5.3.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem szczelność przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem szczelnosc przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N”","categories":["petro"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness of the water space","range":"(0,1 – 0,6) MPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"水腔密封性","range":"(0,1 – 0,6) MPa"}]},{"_id":"6a7d75f9441eff5f156488f0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 – 120) °C"},{"name":"ciśnienie wody","range":"(0,1 – 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.7 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 – 120) °C\ncisnienie wody (0,1 – 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.7","categories":["petro","water"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 – 120) °C"},{"name":"water pressure","range":"(0,1 – 0,3) MPa"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"出水热保护 水温","range":"(0 – 120) °C"},{"name":"水压","range":"(0,1 – 0,3) MPa"}]},{"_id":"6a7d75f9441eff5f156488f1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"szczelność","range":"(0,016 – 2,6) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (0,016 – 2,6) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.11.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.11.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem szczelność (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem szczelnosc (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2","categories":["petro"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness","range":"(0,016 – 2,6) m3/h"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) tightness PN-EN 16510-1:2023-06 p. A.4.11.2","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 密封性 PN-EN 16510-1:2023-06 p. A.4.11.2","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"密封性","range":"(0,016 – 2,6) m3/h"}]},{"_id":"6a7d75f9441eff5f156488f2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p 5.9.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p 5.9.1 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p 5.9.1","categories":["petro"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p 5.9.1","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p 5.9.1","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d75f9441eff5f156488f3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej","range":"(1 – 1500) W,"},{"name":"metoda: przetworników mocy"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\npomiar zużycia energii elektrycznej (1 – 1500) W,\nmetoda: przetworników mocy","reference":"PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","norm_bases":["PN-EN 16510-1:2023-06 p 6.11","PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem Zakres:\npomiar zużycia energii elektrycznej (1 – 1500) W,\nmetoda: przetworników mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem Zakres:\npomiar zuzycia energii elektrycznej (1 – 1500) W,\nmetoda: przetwornikow mocy PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","categories":["petro"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"measurement of electrical energy consumption","range":"(1 – 1500) W,"},{"name":"method: power transducers"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of electrical energy consumption method: power transducers PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 电能消耗测量 方法：功率传感器 PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"电能消耗测量","range":"(1 – 1500) W,"},{"name":"方法：功率传感器"}]},{"_id":"6a7d75f9441eff5f156488f4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p. A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p. A.4.10.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p. A.4.10.4","categories":["petro"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature safety test"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) temperature safety test PN-EN 16510-1:2023-06 p. A.4.10.4","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 温度安全性试验 PN-EN 16510-1:2023-06 p. A.4.10.4","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d75f9441eff5f156488f5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p. A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p. A.4.10.5 Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p. A.4.10.5","categories":["petro"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"safety test under natural draught"}],"search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) safety test under natural draught PN-EN 16510-1:2023-06 p. A.4.10.5","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p. A.4.10.5","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d75f9441eff5f156488f6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"},{"name":"sezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)"},{"name":"wskaźnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)\nwskaźnik efektywności energetycznej EEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6,","PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)\nwskaźnik efektywności energetycznej EEI (z obliczeń) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem Zakres:\nefektywnosc (z obliczen)\nsezonowa efektywnosc energetyczna ogrzewania pomieszczen (z obliczen)\nwskaznik efektywnosci energetycznej EEI (z obliczen) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N”","categories":["petro"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"efficiency (calculated)"},{"name":"seasonal space heating energy efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated) seasonal space heating energy efficiency (calculated) energy efficiency index EEI (calculated) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N”","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 效率（由计算得出） 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","parameters_zh":[{"name":"效率（由计算得出）"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}]},{"_id":"6a7d75f9441eff5f156488f7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,003 – 1) g/m3"}],"technique":"Metoda: grawimetryczna","techniques":["Metoda: grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna","reference":"PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F","PN-EN 16510-2-2:2023-06 p. 4.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Urządzenia zabudowane, w tym z otwartym ogniem Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Urzadzenia zabudowane, w tym z otwartym ogniem Stezenie pylow w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Zalacznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”","categories":["petro"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,003 – 1) g/m3"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Inset appliances, including open fires Dust concentration in flue gases Method: gravimetric Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”","technique_en":"Method: gravimetric","test_object_en":"Residential solid fuel burning appliances - Inset appliances, including open fires","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","parameters_zh":[{"name":"范围","range":"(0,003 – 1) g/m3"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式 烟气中粉尘浓度 方法：重量法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 嵌入式器具，含明火式","methodology_zh":"烟气中粉尘浓度","technique_zh":"方法：重量法"},{"_id":"6a7d75f9441eff5f156488f8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F","PN-EN 16510-2-2:2023-06 p. 4.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Zalacznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”","categories":["petro"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers FUEL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃料参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"燃料参数："},{"_id":"6a7d75f9441eff5f156488f9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 – 20) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 – 20) kg","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"fuel mass","range":"(0,1 – 20) kg"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) fuel mass PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 燃料质量 PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"燃料质量","range":"(0,1 – 20) kg"}]},{"_id":"6a7d75f9441eff5f156488fa","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FLUE GAS PARAMETERS:","search_en":"Residential solid fuel burning appliances - Cookers FLUE GAS PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 烟气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"烟气参数："},{"_id":"6a7d75f9441eff5f156488fb","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 600) °C","reference":"PN-EN 16510-1:2023-06 p. A.2.3.2, A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.2, 4.6.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.2, A.4.4.3","PN-EN 16510-2-3:2023-06 p. 4.6.2, 4.6.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.2.3.2, A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.2, 4.6.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.2.3.2, A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.2, 4.6.3 „N”","categories":["petro"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 600) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 p. A.2.3.2, A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.2, 4.6.3 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 p. A.2.3.2, A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.2, 4.6.3 „N”","parameters_zh":[{"name":"温度","range":"(0 – 600) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d75f9441eff5f156488fc","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"ciśnienie","range":"(0,01 – 200) Pa;"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0,01 – 200) Pa;","reference":"PN-EN 16510-1:2023-06 p. A.2.3.2; A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.2; A.4.4.3","PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki ciśnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.2; A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki cisnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.2; A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","categories":["petro"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(0,01 – 200) Pa;"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 16510-1:2023-06 p. A.2.3.2; A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 16510-1:2023-06 p. A.2.3.2; A.4.4.3 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”","parameters_zh":[{"name":"压力","range":"(0,01 – 200) Pa;"}],"test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d75f9441eff5f156488fd","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"Stężenia dwutlenku węgla, tlenku węgla, tlenu","parameters":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"Emisja CO (z obliczeń)"}],"technique":"Metoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda: PMD- paramagnetyczna","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","reference":"PN-EN 16510-1:2023-06 p. A.2.3; A.4.4.2 | PN-EN 16510-2-3:2023-06 p. 4.2 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3; A.4.4.2","PN-EN 16510-2-3:2023-06 p. 4.2 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-1:2023-06 p. A.2.3; A.4.4.2 | PN-EN 16510-2-3:2023-06 p. 4.2 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki Stezenia dwutlenku wegla, tlenku wegla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczen)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-1:2023-06 p. A.2.3; A.4.4.2 | PN-EN 16510-2-3:2023-06 p. 4.2 „N”","categories":["petro","environment"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of carbon dioxide, carbon monoxide, oxygen","parameters_en":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO emission (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Concentrations of carbon dioxide, carbon monoxide, oxygen NDIR method; Method: PMD- paramagnetic; Electrochemical method Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2; CO; O2; O2; CO emission (calculated) PN-EN 16510-1:2023-06 p. A.2.3; A.4.4.2 | PN-EN 16510-2-3:2023-06 p. 4.2 „N”","technique_en":"NDIR method; Method: PMD- paramagnetic; Electrochemical method","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 二氧化碳、一氧化碳、氧浓度 NDIR 法；PMD 顺磁法；电化学法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 CO 排放量（计算值） PN-EN 16510-1:2023-06 p. A.2.3; A.4.4.2 | PN-EN 16510-2-3:2023-06 p. 4.2 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO 排放量（计算值）"}],"methodology_zh":"二氧化碳、一氧化碳、氧浓度","technique_zh":"NDIR 法；PMD 顺磁法；电化学法"},{"_id":"6a7d75f9441eff5f156488fe","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.","parameters":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencja; Metoda FID","techniques":["Metoda chemiluminescencja","Metoda FID"],"computed":[],"activity":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki Stezenia tlenku azotu, tlenkow azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczen)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”","categories":["petro","environment"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.","parameters_en":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 –1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC. Chemiluminescence method; FID method Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO NOx OGC; (0,269 –1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”","technique_en":"Chemiluminescence method; FID method","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。 化学发光法；FID 法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 NO NOx OGC；(0,269 –1288) mg 有机 C/m3；CO2、NO、NO2、NOx、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”","parameters_zh":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC；(0,269 –1288) mg 有机 C/m3；CO2、NO、NO2、NOx、OGC 排放（由计算得出）"}],"test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。","technique_zh":"化学发光法；FID 法"},{"_id":"6a7d75f9441eff5f156488ff","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E","PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Zalacznik D, Zalacznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”","categories":["petro"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers AIR PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 空气参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"空气参数："},{"_id":"6a7d75f9441eff5f15648900","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"temperatura","range":"(10 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 – 35) °C","reference":"PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3","categories":["petro"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(10 – 35) °C"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 – 35) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d75f9441eff5f15648901","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3","categories":["petro","water"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"WATER PARAMETERS:","search_en":"Residential solid fuel burning appliances - Cookers WATER PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 水参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.1.1; A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"水参数："},{"_id":"6a7d75f9441eff5f15648902","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 100) °C","reference":"PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.5; A.4.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki temperatura (0 – 100) °C PN-EN 16510-1:2023-06 p. A.2.5; A.4.5 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki temperatura (0 – 100) °C PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","categories":["petro"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 100) °C"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","parameters_zh":[{"name":"温度","range":"(0 – 100) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d75f9441eff5f15648903","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"strumień objętości:","range":"(0,24 – 12) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości: (0,24 – 12) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.5; A.4.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki strumień objętości: (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.2.5; A.4.5 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki strumien objetosci: (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","categories":["petro"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"volume flow rate:","range":"(0,24 – 12) m3/h"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) volume flow rate: PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d75f9441eff5f15648904","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.5; A.4.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.2.5; A.4.5 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","categories":["petro"],"row_index":297,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"HEAT BALANCE (calculated):","search_en":"Residential solid fuel burning appliances - Cookers HEAT BALANCE (calculated): Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 热平衡（计算值）： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.2.5; A.4.5","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d75f9441eff5f15648905","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 – 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 – 60) kW","reference":"PN-EN 16510-1:2023-06 p. A.4.5; A.4.8; A.4.9, A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5; A.4.8; A.4.9, A.6.2.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki moc cieplna doprowadzona z paliwem (3 – 60) kW PN-EN 16510-1:2023-06 p. A.4.5; A.4.8; A.4.9, A.6.2.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki moc cieplna doprowadzona z paliwem (3 – 60) kW PN-EN 16510-1:2023-06 p. A.4.5; A.4.8; A.4.9, A.6.2.2","categories":["petro"],"row_index":298,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat input from fuel","range":"(3 – 60) kW"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) heat input from fuel PN-EN 16510-1:2023-06 p. A.4.5; A.4.8; A.4.9, A.6.2.2","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 燃料输入热功率 PN-EN 16510-1:2023-06 p. A.4.5; A.4.8; A.4.9, A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"燃料输入热功率","range":"(3 – 60) kW"}]},{"_id":"6a7d75f9441eff5f15648906","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 – 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 – 40) %","reference":"PN-EN 16510-1:2023-06 p. A.4.4, A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4, A.6.2.1.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.4.4, A.6.2.1.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.4.4, A.6.2.1.2","categories":["petro"],"row_index":299,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"stack loss","range":"(5 – 40) %"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) stack loss PN-EN 16510-1:2023-06 p. A.4.4, A.6.2.1.2","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 排烟热损失 PN-EN 16510-1:2023-06 p. A.4.4, A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"排烟热损失","range":"(5 – 40) %"}]},{"_id":"6a7d75f9441eff5f15648907","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki straty niezupełnego spalania PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki straty niezupelnego spalania PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.3","categories":["petro"],"row_index":300,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"losses due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) losses due to incomplete combustion PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.3","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f15648908","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki strata niecałkowitego spalania PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki strata niecalkowitego spalania PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.4","categories":["petro"],"row_index":301,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) loss due to incomplete combustion PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.4","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.4.4; A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f15648909","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 – 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 – 95) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1","PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki sprawność cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki sprawnosc cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”","categories":["petro"],"row_index":302,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal efficiency","range":"(20 – 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 16510-1:2023-06 p. A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"热效率","range":"(20 – 95) %"}]},{"_id":"6a7d75f9441eff5f1564890a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.2","PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki łączna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki laczna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”","categories":["petro"],"row_index":303,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"total heat output","range":"(3 – 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. total heat output PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总热功率 PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"总热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f1564890b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.3","PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki moc cieplna obiegu wodnego (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki moc cieplna obiegu wodnego (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”","categories":["petro"],"row_index":304,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output of the water circuit","range":"(3 – 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"水循环回路热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f1564890c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4","categories":["petro"],"row_index":305,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output to the room","range":"(3 – 50) kW"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) heat output to the room PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 向房间输出的热功率 PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f1564890d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(5 – 100) g/s"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy spalin (5 – 100) g/s","reference":"PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.5","PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki strumień masy spalin (5 – 100) g/s PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki strumien masy spalin (5 – 100) g/s PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","categories":["petro"],"row_index":306,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"flue gas mass flow","range":"(5 – 100) g/s"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"烟气质量流量","range":"(5 – 100) g/s"}]},{"_id":"6a7d75f9441eff5f1564890e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"zawartość CO (O2=13 %)","range":"(0,001 – 0,5) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13 %) (0,001 – 0,5) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki zawartość CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki zawartosc CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":307,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"CO content (O2=13 %)","range":"(0,001 – 0,5) %"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) CO content (O2=13 %) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） CO 含量（O2=13 %） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"CO 含量（O2=13 %）","range":"(0,001 – 0,5) %"}]},{"_id":"6a7d75f9441eff5f1564890f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":308,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","search_en":"Residential solid fuel burning appliances - Cookers TECHNICAL AND OPERATIONAL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 技术与运行参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"技术与运行参数："},{"_id":"6a7d75f9441eff5f15648910","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 – 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 – 200) °C"},{"name":"temperatura uchwytów","range":"(0 – 300) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 300) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.7 | PN-EN 16510-2-3:2023-06 p. 5.5, 5.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.7","PN-EN 16510-2-3:2023-06 p. 5.5, 5.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7 | PN-EN 16510-2-3:2023-06 p. 5.5, 5.6 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki Zakres:\ntemperatura naroznika pomiarowego i podloza (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytow (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7 | PN-EN 16510-2-3:2023-06 p. 5.5, 5.6 „N”","categories":["petro"],"row_index":309,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 – 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 – 200) °C"},{"name":"temperature of handles","range":"(0 – 300) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 16510-1:2023-06 p. A.4.7 | PN-EN 16510-2-3:2023-06 p. 5.5, 5.6 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p. A.4.7 | PN-EN 16510-2-3:2023-06 p. 5.5, 5.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 – 200) °C"},{"name":"燃料储斗温度","range":"(0 – 200) °C"},{"name":"手柄温度","range":"(0 – 300) °C"}]},{"_id":"6a7d75f9441eff5f15648911","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 – 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 – 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.3.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6","PN-EN 16510-2-3:2023-06 p. 5.3.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki szczelność przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.3.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki szczelnosc przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.3.3 „N”","categories":["petro"],"row_index":310,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness of the water space","range":"(0,1 – 0,6) MPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.3.3 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.3.3 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"水腔密封性","range":"(0,1 – 0,6) MPa"}]},{"_id":"6a7d75f9441eff5f15648912","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 – 120) °C"},{"name":"ciśnienie wody","range":"(0,1 – 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa","reference":"PN-EN 16510:2023-06 p. A.4.10.7","norm_bases":["PN-EN 16510:2023-06 p. A.4.10.7"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa PN-EN 16510:2023-06 p. A.4.10.7 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 – 120) °C\ncisnienie wody (0,1 – 0,3) MPa PN-EN 16510:2023-06 p. A.4.10.7","categories":["petro","water"],"row_index":311,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 – 120) °C"},{"name":"water pressure","range":"(0,1 – 0,3) MPa"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) thermal outlet safety device water temperature water pressure PN-EN 16510:2023-06 p. A.4.10.7","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 出水热保护 水温 水压 PN-EN 16510:2023-06 p. A.4.10.7","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"出水热保护 水温","range":"(0 – 120) °C"},{"name":"水压","range":"(0,1 – 0,3) MPa"}]},{"_id":"6a7d75f9441eff5f15648913","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"gotowanie, temperatura wody","range":"(0 – 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"gotowanie, temperatura wody (0 – 100) °C","reference":"PN-EN 16510-1:2023-06","norm_bases":["PN-EN 16510-1:2023-06"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki gotowanie, temperatura wody (0 – 100) °C PN-EN 16510-1:2023-06 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki gotowanie, temperatura wody (0 – 100) °C PN-EN 16510-1:2023-06","categories":["petro","water"],"row_index":312,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"boiling, water temperature","range":"(0 – 100) °C"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) boiling, water temperature PN-EN 16510-1:2023-06","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d75f9441eff5f15648914","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"pieczenie, temperatura powietrza","range":"(0 – 300) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"pieczenie, temperatura powietrza (0 – 300) °C","reference":"PN-EN 16510-1:2023-06","norm_bases":["PN-EN 16510-1:2023-06"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki pieczenie, temperatura powietrza (0 – 300) °C PN-EN 16510-1:2023-06 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki pieczenie, temperatura powietrza (0 – 300) °C PN-EN 16510-1:2023-06","categories":["petro"],"row_index":313,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"baking, air temperature","range":"(0 – 300) °C"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) baking, air temperature PN-EN 16510-1:2023-06","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 烘烤、空气温度 PN-EN 16510-1:2023-06","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"烘烤、空气温度","range":"(0 – 300) °C"}]},{"_id":"6a7d75f9441eff5f15648915","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"szczelność","range":"(0,016 – 2,6) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (0,016 – 2,6) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.11.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.11.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki szczelność (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki szczelnosc (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2","categories":["petro"],"row_index":314,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness","range":"(0,016 – 2,6) m3/h"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) tightness PN-EN 16510-1:2023-06 p. A.4.11.2","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 密封性 PN-EN 16510-1:2023-06 p. A.4.11.2","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"密封性","range":"(0,016 – 2,6) m3/h"}]},{"_id":"6a7d75f9441eff5f15648916","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"badanie półki piekarnika"}],"technique":null,"techniques":[],"computed":[],"activity":"badanie półki piekarnika","reference":"PN-EN 16510-2-3:2023-06 p. A.4.301.4 „N”","norm_bases":["PN-EN 16510-2-3:2023-06 p. A.4.301.4 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki badanie półki piekarnika PN-EN 16510-2-3:2023-06 p. A.4.301.4 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki badanie polki piekarnika PN-EN 16510-2-3:2023-06 p. A.4.301.4 „N”","categories":["petro"],"row_index":315,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"testing of the oven shelf"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. testing of the oven shelf PN-EN 16510-2-3:2023-06 p. A.4.301.4 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-2-3:2023-06 p. A.4.301.4 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d75f9441eff5f15648917","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"badanie drzwi piekarnika"}],"technique":null,"techniques":[],"computed":[],"activity":"badanie drzwi piekarnika","reference":"PN-EN 16510-2-3:2023-06 p. A.4.301.5 „N”","norm_bases":["PN-EN 16510-2-3:2023-06 p. A.4.301.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki badanie drzwi piekarnika PN-EN 16510-2-3:2023-06 p. A.4.301.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki badanie drzwi piekarnika PN-EN 16510-2-3:2023-06 p. A.4.301.5 „N”","categories":["petro"],"row_index":316,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"testing of the oven door"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. testing of the oven door PN-EN 16510-2-3:2023-06 p. A.4.301.5 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-2-3:2023-06 p. A.4.301.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具"},{"_id":"6a7d75f9441eff5f15648918","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p. 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p. 5.9.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p. 5.9.1 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p. 5.9.1","categories":["petro"],"row_index":317,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p. 5.9.1","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p. 5.9.1","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d75f9441eff5f15648919","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej","range":"(1 – 1500) W,"},{"name":"metoda: przetworników mocy"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\npomiar zużycia energii elektrycznej (1 – 1500) W,\nmetoda: przetworników mocy","reference":"PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. 6.11","PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki Zakres:\npomiar zużycia energii elektrycznej (1 – 1500) W,\nmetoda: przetworników mocy PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki Zakres:\npomiar zuzycia energii elektrycznej (1 – 1500) W,\nmetoda: przetwornikow mocy PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","categories":["petro"],"row_index":318,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"measurement of electrical energy consumption","range":"(1 – 1500) W,"},{"name":"method: power transducers"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of electrical energy consumption method: power transducers PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 电能消耗测量 方法：功率传感器 PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"电能消耗测量","range":"(1 – 1500) W,"},{"name":"方法：功率传感器"}]},{"_id":"6a7d75f9441eff5f1564891a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p. A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p. A.4.10.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p. A.4.10.4","categories":["petro"],"row_index":319,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature safety test"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) temperature safety test PN-EN 16510-1:2023-06 p. A.4.10.4","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 温度安全性试验 PN-EN 16510-1:2023-06 p. A.4.10.4","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d75f9441eff5f1564891b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p. A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p. A.4.10.5 Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p. A.4.10.5","categories":["petro"],"row_index":320,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"safety test under natural draught"}],"search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) safety test under natural draught PN-EN 16510-1:2023-06 p. A.4.10.5","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p. A.4.10.5","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d75f9441eff5f1564891c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"},{"name":"sezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)"},{"name":"wskaźnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)\nwskaźnik efektywności energetycznej EEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1. | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.","PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)\nwskaźnik efektywności energetycznej EEI (z obliczeń) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1. | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki Zakres:\nefektywnosc (z obliczen)\nsezonowa efektywnosc energetyczna ogrzewania pomieszczen (z obliczen)\nwskaznik efektywnosci energetycznej EEI (z obliczen) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1. | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”","categories":["petro"],"row_index":321,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"efficiency (calculated)"},{"name":"seasonal space heating energy efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated) seasonal space heating energy efficiency (calculated) energy efficiency index EEI (calculated) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1. | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 效率（由计算得出） 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1. | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","parameters_zh":[{"name":"效率（由计算得出）"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}]},{"_id":"6a7d75f9441eff5f1564891d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,003 – 1) g/m3"}],"technique":"Metoda: grawimetryczna","techniques":["Metoda: grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna","reference":"PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F","PN-EN 16510-2-3:2023-06 p. 4.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Kuchenki Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Kuchenki Stezenie pylow w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Zalacznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","categories":["petro"],"row_index":322,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,003 – 1) g/m3"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Cookers Dust concentration in flue gases Method: gravimetric Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","technique_en":"Method: gravimetric","test_object_en":"Residential solid fuel burning appliances - Cookers","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","parameters_zh":[{"name":"范围","range":"(0,003 – 1) g/m3"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 炊具 烟气中粉尘浓度 方法：重量法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 炊具","methodology_zh":"烟气中粉尘浓度","technique_zh":"方法：重量法"},{"_id":"6a7d75f9441eff5f1564891e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F","PN-EN 16510-2-3:2023-06 p. 4.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N” Kotly grzewcze na paliwa stale do 50 kW PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Zalacznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","categories":["petro"],"row_index":323,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Heating boilers for solid fuels up to 50 kW FUEL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"50 kW 以下固体燃料供暖锅炉 燃料参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”","methodology_zh":"燃料参数：","test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564891f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 – 20) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 – 20) kg","reference":"PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2","norm_bases":["PN-EN 12809:2002 p. A.4.2","PN-EN 16510-1:2018-08 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW masa paliwa (0,1 – 20) kg PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2 Kotly grzewcze na paliwa stale do 50 kW masa paliwa (0,1 – 20) kg PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2","categories":["petro"],"row_index":324,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"fuel mass","range":"(0,1 – 20) kg"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) fuel mass PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 燃料质量 PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2","parameters_zh":[{"name":"燃料质量","range":"(0,1 – 20) kg"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648920","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2","norm_bases":["PN-EN 12809:2002 p. A.4.2","PN-EN 16510-1:2018-08 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW PARAMETRY SPALIN: PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2 Kotly grzewcze na paliwa stale do 50 kW PARAMETRY SPALIN: PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2","categories":["petro"],"row_index":325,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FLUE GAS PARAMETERS:","search_en":"Heating boilers for solid fuels up to 50 kW FLUE GAS PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 烟气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 12809:2002 p. A.4.2 | PN-EN 16510-1:2018-08 p. A.4.2","methodology_zh":"烟气参数：","test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648921","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 600) °C","reference":"PN-EN 12809:2002 p. A.2.3.2. | PN-EN 16510:2018-08 p. A.2.3.2","norm_bases":["PN-EN 12809:2002 p. A.2.3.2.","PN-EN 16510:2018-08 p. A.2.3.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW temperatura (0 – 600) °C PN-EN 12809:2002 p. A.2.3.2. | PN-EN 16510:2018-08 p. A.2.3.2 Kotly grzewcze na paliwa stale do 50 kW temperatura (0 – 600) °C PN-EN 12809:2002 p. A.2.3.2. | PN-EN 16510:2018-08 p. A.2.3.2","categories":["petro"],"row_index":326,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 600) °C"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 12809:2002 p. A.2.3.2. | PN-EN 16510:2018-08 p. A.2.3.2","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 12809:2002 p. A.2.3.2. | PN-EN 16510:2018-08 p. A.2.3.2","parameters_zh":[{"name":"温度","range":"(0 – 600) °C"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648922","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"ciśnienie","range":"(0,01 – 250) Pa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0,01 – 250) Pa","reference":"PN-EN 12809:2002 p. A.2.3.4; A4 | PN-EN 16510:2018-08 p. A.2.3.4; A.4","norm_bases":["PN-EN 12809:2002 p. A.2.3.4; A4","PN-EN 16510:2018-08 p. A.2.3.4; A.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW ciśnienie (0,01 – 250) Pa PN-EN 12809:2002 p. A.2.3.4; A4 | PN-EN 16510:2018-08 p. A.2.3.4; A.4 Kotly grzewcze na paliwa stale do 50 kW cisnienie (0,01 – 250) Pa PN-EN 12809:2002 p. A.2.3.4; A4 | PN-EN 16510:2018-08 p. A.2.3.4; A.4","categories":["petro"],"row_index":327,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(0,01 – 250) Pa"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) pressure PN-EN 12809:2002 p. A.2.3.4; A4 | PN-EN 16510:2018-08 p. A.2.3.4; A.4","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 压力 PN-EN 12809:2002 p. A.2.3.4; A4 | PN-EN 16510:2018-08 p. A.2.3.4; A.4","parameters_zh":[{"name":"压力","range":"(0,01 – 250) Pa"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648923","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"Stężenia dwutlenku węgla, tlenku węgla, tlenu","parameters":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,800) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"Emisja CO (z obliczeń)"}],"technique":"Metoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda: PMD- paramagnetyczna","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,800) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","reference":"PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3 | PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3","norm_bases":["PN-EN 12809:2002 p. A.2.3.3","PN-EN 16510-1:2018-08 p. A.2.3.3","PN-EN 12809:2002 p. A.2.3.3","PN-EN 16510-1:2018-08 p. A.2.3.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,800) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3 | PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3 Kotly grzewcze na paliwa stale do 50 kW Stezenia dwutlenku wegla, tlenku wegla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,800) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczen)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3 | PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3","categories":["environment","petro"],"row_index":328,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of carbon dioxide, carbon monoxide, oxygen","parameters_en":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,800) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO emission (calculated)"}],"search_en":"Heating boilers for solid fuels up to 50 kW Concentrations of carbon dioxide, carbon monoxide, oxygen NDIR method; Method: PMD- paramagnetic; Electrochemical method Gas and Heating Appliances Testing Laboratory (GU-1) CO2; CO; O2; O2; CO emission (calculated) PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3 | PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3","technique_en":"NDIR method; Method: PMD- paramagnetic; Electrochemical method","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 二氧化碳、一氧化碳、氧浓度 NDIR 法；PMD 顺磁法；电化学法 燃气与供暖器具检测实验室（GU-1） CO 排放量（计算值） PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3 | PN-EN 12809:2002 p. A.2.3.3 | PN-EN 16510-1:2018-08 p. A.2.3.3","parameters_zh":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,800) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO 排放量（计算值）"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉","methodology_zh":"二氧化碳、一氧化碳、氧浓度","technique_zh":"NDIR 法；PMD 顺磁法；电化学法"},{"_id":"6a7d75f9441eff5f15648924","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"Stężenia tlenku azotu, dwutlenku azotu, tlenków azotu (NO, NO2, NOx), OGC.","parameters":[{"name":"NO","range":"(0,1 – 1993) ppm"},{"name":"NO2","range":"(0,1 – 232) ppm"},{"name":"NOx","range":"(0,1 – 1993) ppm"},{"name":"NO","range":"(0,5 – 190) ppm"},{"name":"NOx","range":"(0,5 – 190) ppm"},{"name":"OGC","range":"(0,269 – 1286) mg/m3"},{"name":"Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"technique":"Metoda NDIR; Metoda chemiluminescencja; Metoda FID","techniques":["Metoda NDIR","Metoda chemiluminescencja","Metoda FID"],"computed":[],"activity":"Stężenia tlenku azotu, dwutlenku azotu, tlenków azotu (NO, NO2, NOx), OGC.\nZakres:\nNO (0,1 – 1993) ppm\nNO2 (0,1 – 232) ppm\nNOx (0,1 – 1993) ppm\nNO (0,5 – 190) ppm\nNOx (0,5 – 190) ppm\nOGC (0,269 – 1286) mg/m3\nEmisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda NDIR; Metoda chemiluminescencja; Metoda FID","reference":"PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E","norm_bases":["PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW Stężenia tlenku azotu, dwutlenku azotu, tlenków azotu (NO, NO2, NOx), OGC.\nZakres:\nNO (0,1 – 1993) ppm\nNO2 (0,1 – 232) ppm\nNOx (0,1 – 1993) ppm\nNO (0,5 – 190) ppm\nNOx (0,5 – 190) ppm\nOGC (0,269 – 1286) mg/m3\nEmisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda NDIR; Metoda chemiluminescencja; Metoda FID PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E Kotly grzewcze na paliwa stale do 50 kW Stezenia tlenku azotu, dwutlenku azotu, tlenkow azotu (NO, NO2, NOx), OGC.\nZakres:\nNO (0,1 – 1993) ppm\nNO2 (0,1 – 232) ppm\nNOx (0,1 – 1993) ppm\nNO (0,5 – 190) ppm\nNOx (0,5 – 190) ppm\nOGC (0,269 – 1286) mg/m3\nEmisja CO2; NO, NO2, NOx, OGC (z obliczen)\nMetoda NDIR; Metoda chemiluminescencja; Metoda FID PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Zalacznik E","categories":["environment","petro"],"row_index":329,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of nitrogen monoxide, nitrogen dioxide, nitrogen oxides (NO, NO2, NOx), OGC.","parameters_en":[{"name":"NO","range":"(0,1 – 1993) ppm"},{"name":"NO2","range":"(0,1 – 232) ppm"},{"name":"NOx","range":"(0,1 – 1993) ppm"},{"name":"NO","range":"(0,5 – 190) ppm"},{"name":"NOx","range":"(0,5 – 190) ppm"},{"name":"OGC","range":"(0,269 – 1286) mg/m3"},{"name":"CO2; NO, NO2, NOx, OGC emission (calculated)"}],"search_en":"Heating boilers for solid fuels up to 50 kW Concentrations of nitrogen monoxide, nitrogen dioxide, nitrogen oxides (NO, NO2, NOx), OGC. NDIR method; Chemiluminescence method; FID method Gas and Heating Appliances Testing Laboratory (GU-1) NO NO2 NOx NO NOx OGC CO2; NO, NO2, NOx, OGC emission (calculated) PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E","technique_en":"NDIR method; Chemiluminescence method; FID method","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） NO NO2 NOx NO NOx 总有机气态碳（OGC） CO2、NO、NO2、NOx、OGC 排放（由计算得出） PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E","parameters_zh":[{"name":"NO","range":"(0,1 – 1993) ppm"},{"name":"NO2","range":"(0,1 – 232) ppm"},{"name":"NOx","range":"(0,1 – 1993) ppm"},{"name":"NO","range":"(0,5 – 190) ppm"},{"name":"NOx","range":"(0,5 – 190) ppm"},{"name":"总有机气态碳（OGC）","range":"(0,269 – 1286) mg/m3"},{"name":"CO2、NO、NO2、NOx、OGC 排放（由计算得出）"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648925","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E","norm_bases":["PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW PARAMETRY POWIETRZA: PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E Kotly grzewcze na paliwa stale do 50 kW PARAMETRY POWIETRZA: PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Zalacznik E","categories":["petro"],"row_index":330,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"AIR PARAMETERS:","search_en":"Heating boilers for solid fuels up to 50 kW AIR PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 空气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2018-08 p. 7.3; A.2; A.3; A.7; D.2.2; D.2.3; Załącznik E","methodology_zh":"空气参数：","test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648926","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"temperatura","range":"(10 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 – 35) °C","reference":"PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1","norm_bases":["PN-EN 12809:2002 p. A.1.1.","PN-EN 16510-1:2018-08 p.A.1.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW temperatura (10 – 35) °C PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1 Kotly grzewcze na paliwa stale do 50 kW temperatura (10 – 35) °C PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1","categories":["petro"],"row_index":331,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(10 – 35) °C"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1","parameters_zh":[{"name":"温度","range":"(10 – 35) °C"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648927","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1","norm_bases":["PN-EN 12809:2002 p. A.1.1.","PN-EN 16510-1:2018-08 p.A.1.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW PARAMETRY WODY: PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1 Kotly grzewcze na paliwa stale do 50 kW PARAMETRY WODY: PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1","categories":["water","petro"],"row_index":332,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"WATER PARAMETERS:","search_en":"Heating boilers for solid fuels up to 50 kW WATER PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 水参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 12809:2002 p. A.1.1. | PN-EN 16510-1:2018-08 p.A.1.1","methodology_zh":"水参数：","test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648928","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 100) °C","reference":"PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","norm_bases":["PN-EN 12809:2002 p. A.2.5","PN-EN 16510-1:2018-08 p.A.2.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW temperatura (0 – 100) °C PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5 Kotly grzewcze na paliwa stale do 50 kW temperatura (0 – 100) °C PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","categories":["petro"],"row_index":333,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 100) °C"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","parameters_zh":[{"name":"温度","range":"(0 – 100) °C"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648929","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"strumień objętości :","range":"(0,09 – 12) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości : (0,09 – 12) m3/h","reference":"PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","norm_bases":["PN-EN 12809:2002 p. A.2.5","PN-EN 16510-1:2018-08 p.A.2.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW strumień objętości : (0,09 – 12) m3/h PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5 Kotly grzewcze na paliwa stale do 50 kW strumien objetosci : (0,09 – 12) m3/h PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","categories":["petro"],"row_index":334,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"volume flow rate :","range":"(0,09 – 12) m3/h"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) volume flow rate : PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 体积流量： PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","test_object_zh":"50 kW 以下固体燃料供暖锅炉","parameters_zh":[{"name":"体积流量：","range":"(0,09 – 12) m3/h"}]},{"_id":"6a7d75f9441eff5f1564892a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","norm_bases":["PN-EN 12809:2002 p. A.2.5","PN-EN 16510-1:2018-08 p.A.2.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW BILANS CIEPLNY (z obliczeń): PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5 Kotly grzewcze na paliwa stale do 50 kW BILANS CIEPLNY (z obliczen): PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","categories":["petro"],"row_index":335,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"HEAT BALANCE (calculated):","search_en":"Heating boilers for solid fuels up to 50 kW HEAT BALANCE (calculated): Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 热平衡（计算值）： 燃气与供暖器具检测实验室（GU-1） PN-EN 12809:2002 p. A.2.5 | PN-EN 16510-1:2018-08 p.A.2.5","methodology_zh":"热平衡（计算值）：","test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564892b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(5 – 100) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (5 – 100) kW","reference":"PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2","norm_bases":["PN-EN 12809:2002 p. A.6.2.2","PN-EN 16510-1:2018-08 p.A.6.2.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW moc cieplna doprowadzona z paliwem (5 – 100) kW PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2 Kotly grzewcze na paliwa stale do 50 kW moc cieplna doprowadzona z paliwem (5 – 100) kW PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2","categories":["petro"],"row_index":336,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat input from fuel","range":"(5 – 100) kW"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) heat input from fuel PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 燃料输入热功率 PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2","parameters_zh":[{"name":"燃料输入热功率","range":"(5 – 100) kW"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564892c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 – 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 – 40) %","reference":"PN-EN 12809:2002 p. A.6.2.1.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.2","norm_bases":["PN-EN 12809:2002 p. A.6.2.1.1","PN-EN 16510-1:2018-08 p.A.6.2.1.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW strata kominowa (5 – 40) % PN-EN 12809:2002 p. A.6.2.1.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.2 Kotly grzewcze na paliwa stale do 50 kW strata kominowa (5 – 40) % PN-EN 12809:2002 p. A.6.2.1.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.2","categories":["petro"],"row_index":337,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"stack loss","range":"(5 – 40) %"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) stack loss PN-EN 12809:2002 p. A.6.2.1.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.2","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 排烟热损失 PN-EN 12809:2002 p. A.6.2.1.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.2","parameters_zh":[{"name":"排烟热损失","range":"(5 – 40) %"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564892d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 12809:2002 p. A.6.2.1.2 | PN-EN 16510-1:2018-08 p.A.6.2.1.3","norm_bases":["PN-EN 12809:2002 p. A.6.2.1.2","PN-EN 16510-1:2018-08 p.A.6.2.1.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW straty niezupełnego spalania PN-EN 12809:2002 p. A.6.2.1.2 | PN-EN 16510-1:2018-08 p.A.6.2.1.3 Kotly grzewcze na paliwa stale do 50 kW straty niezupelnego spalania PN-EN 12809:2002 p. A.6.2.1.2 | PN-EN 16510-1:2018-08 p.A.6.2.1.3","categories":["petro"],"row_index":338,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"losses due to incomplete combustion"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) losses due to incomplete combustion PN-EN 12809:2002 p. A.6.2.1.2 | PN-EN 16510-1:2018-08 p.A.6.2.1.3","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 12809:2002 p. A.6.2.1.2 | PN-EN 16510-1:2018-08 p.A.6.2.1.3","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564892e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 12809:2002 p. A.6.2.1.3 | PN-EN 16510-1:2018-08 p.A.6.2.1.4","norm_bases":["PN-EN 12809:2002 p. A.6.2.1.3","PN-EN 16510-1:2018-08 p.A.6.2.1.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW strata niecałkowitego spalania PN-EN 12809:2002 p. A.6.2.1.3 | PN-EN 16510-1:2018-08 p.A.6.2.1.4 Kotly grzewcze na paliwa stale do 50 kW strata niecalkowitego spalania PN-EN 12809:2002 p. A.6.2.1.3 | PN-EN 16510-1:2018-08 p.A.6.2.1.4","categories":["petro"],"row_index":339,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss due to incomplete combustion"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) loss due to incomplete combustion PN-EN 12809:2002 p. A.6.2.1.3 | PN-EN 16510-1:2018-08 p.A.6.2.1.4","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 12809:2002 p. A.6.2.1.3 | PN-EN 16510-1:2018-08 p.A.6.2.1.4","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564892f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 – 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 – 95) %","reference":"PN-EN 12809:2002 p. A.6.2.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.1","norm_bases":["PN-EN 12809:2002 p. A.6.2.1","PN-EN 16510-1:2018-08 p.A.6.2.1.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW sprawność cieplna (20 – 95) % PN-EN 12809:2002 p. A.6.2.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.1 Kotly grzewcze na paliwa stale do 50 kW sprawnosc cieplna (20 – 95) % PN-EN 12809:2002 p. A.6.2.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.1","categories":["petro"],"row_index":340,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal efficiency","range":"(20 – 95) %"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) thermal efficiency PN-EN 12809:2002 p. A.6.2.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.1","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 热效率 PN-EN 12809:2002 p. A.6.2.1 | PN-EN 16510-1:2018-08 p.A.6.2.1.1","parameters_zh":[{"name":"热效率","range":"(20 – 95) %"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648930","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 – 50) kW","reference":"PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2","norm_bases":["PN-EN 12809:2002 p. A.6.2.2","PN-EN 16510-1:2018-08 p.A.6.2.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW łączna moc cieplna (3 – 50) kW PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2 Kotly grzewcze na paliwa stale do 50 kW laczna moc cieplna (3 – 50) kW PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2","categories":["petro"],"row_index":341,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"total heat output","range":"(3 – 50) kW"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) total heat output PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 总热功率 PN-EN 12809:2002 p. A.6.2.2 | PN-EN 16510-1:2018-08 p.A.6.2.2","parameters_zh":[{"name":"总热功率","range":"(3 – 50) kW"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648931","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (3 – 50) kW","reference":"PN-EN 12809:2002 p. A.6.2.3 | PN-EN 16510-1:2018-08 p.A.6.2.3","norm_bases":["PN-EN 12809:2002 p. A.6.2.3","PN-EN 16510-1:2018-08 p.A.6.2.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW moc cieplna obiegu wodnego (3 – 50) kW PN-EN 12809:2002 p. A.6.2.3 | PN-EN 16510-1:2018-08 p.A.6.2.3 Kotly grzewcze na paliwa stale do 50 kW moc cieplna obiegu wodnego (3 – 50) kW PN-EN 12809:2002 p. A.6.2.3 | PN-EN 16510-1:2018-08 p.A.6.2.3","categories":["petro"],"row_index":342,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output of the water circuit","range":"(3 – 50) kW"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) heat output of the water circuit PN-EN 12809:2002 p. A.6.2.3 | PN-EN 16510-1:2018-08 p.A.6.2.3","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 水循环回路热功率 PN-EN 12809:2002 p. A.6.2.3 | PN-EN 16510-1:2018-08 p.A.6.2.3","test_object_zh":"50 kW 以下固体燃料供暖锅炉","parameters_zh":[{"name":"水循环回路热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f15648932","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(5 – 100) g/s"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy spalin (5 – 100) g/s","reference":"PN-EN 12809:2002 p. A.6.2.4 | PN-EN 16510-1:2018-08 p.A.6.2.4","norm_bases":["PN-EN 12809:2002 p. A.6.2.4","PN-EN 16510-1:2018-08 p.A.6.2.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW strumień masy spalin (5 – 100) g/s PN-EN 12809:2002 p. A.6.2.4 | PN-EN 16510-1:2018-08 p.A.6.2.4 Kotly grzewcze na paliwa stale do 50 kW strumien masy spalin (5 – 100) g/s PN-EN 12809:2002 p. A.6.2.4 | PN-EN 16510-1:2018-08 p.A.6.2.4","categories":["petro"],"row_index":343,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"flue gas mass flow","range":"(5 – 100) g/s"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) flue gas mass flow PN-EN 12809:2002 p. A.6.2.4 | PN-EN 16510-1:2018-08 p.A.6.2.4","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 烟气质量流量 PN-EN 12809:2002 p. A.6.2.4 | PN-EN 16510-1:2018-08 p.A.6.2.4","test_object_zh":"50 kW 以下固体燃料供暖锅炉","parameters_zh":[{"name":"烟气质量流量","range":"(5 – 100) g/s"}]},{"_id":"6a7d75f9441eff5f15648933","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 – 50) kW","reference":"PN-EN 12809:2002 p. A.6.2.5 | PN-EN 16510-1:2018-08 p.A.6.2.5","norm_bases":["PN-EN 12809:2002 p. A.6.2.5","PN-EN 16510-1:2018-08 p.A.6.2.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 12809:2002 p. A.6.2.5 | PN-EN 16510-1:2018-08 p.A.6.2.5 Kotly grzewcze na paliwa stale do 50 kW moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 12809:2002 p. A.6.2.5 | PN-EN 16510-1:2018-08 p.A.6.2.5","categories":["petro"],"row_index":344,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output to the room","range":"(3 – 50) kW"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) heat output to the room PN-EN 12809:2002 p. A.6.2.5 | PN-EN 16510-1:2018-08 p.A.6.2.5","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 向房间输出的热功率 PN-EN 12809:2002 p. A.6.2.5 | PN-EN 16510-1:2018-08 p.A.6.2.5","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 – 50) kW"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648934","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"zawartość CO","range":"(O2=13 %)"},{"name":"(0,001 – 0,800 )%"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzawartość CO (O2=13 %)\n(0,001 – 0,800 )%","reference":"PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6","norm_bases":["PN-EN 12809:2002 p. A.6.2.6","PN-EN 16510-1:2018-08 p.A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW Zakres:\nzawartość CO (O2=13 %)\n(0,001 – 0,800 )% PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6 Kotly grzewcze na paliwa stale do 50 kW Zakres:\nzawartosc CO (O2=13 %)\n(0,001 – 0,800 )% PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6","categories":["petro"],"row_index":345,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"CO content","range":"(O2=13 %)"},{"name":"(0,001 – 0,800 )%"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) CO content (0,001 – 0,800 )% PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6","test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648935","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6","norm_bases":["PN-EN 12809:2002 p. A.6.2.6","PN-EN 16510-1:2018-08 p.A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6 Kotly grzewcze na paliwa stale do 50 kW PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6","categories":["petro"],"row_index":346,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","search_en":"Heating boilers for solid fuels up to 50 kW TECHNICAL AND OPERATIONAL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 技术与运行参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 12809:2002 p. A.6.2.6 | PN-EN 16510-1:2018-08 p.A.6.2.6","test_object_zh":"50 kW 以下固体燃料供暖锅炉","methodology_zh":"技术与运行参数："},{"_id":"6a7d75f9441eff5f15648936","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 – 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 – 200) °C"},{"name":"temperatura uchwytów","range":"(0 – 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 200) °C","reference":"PN-EN 12809:2002 p. A.2; A.3 | PN-EN 16510-1:2018-08 p.A.2.; A.3","norm_bases":["PN-EN 12809:2002 p. A.2; A.3","PN-EN 16510-1:2018-08 p.A.2.; A.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 200) °C PN-EN 12809:2002 p. A.2; A.3 | PN-EN 16510-1:2018-08 p.A.2.; A.3 Kotly grzewcze na paliwa stale do 50 kW Zakres:\ntemperatura naroznika pomiarowego i podloza (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytow (0 – 200) °C PN-EN 12809:2002 p. A.2; A.3 | PN-EN 16510-1:2018-08 p.A.2.; A.3","categories":["petro"],"row_index":347,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 – 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 – 200) °C"},{"name":"temperature of handles","range":"(0 – 200) °C"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 12809:2002 p. A.2; A.3 | PN-EN 16510-1:2018-08 p.A.2.; A.3","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 12809:2002 p. A.2; A.3 | PN-EN 16510-1:2018-08 p.A.2.; A.3","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 – 200) °C"},{"name":"燃料储斗温度","range":"(0 – 200) °C"},{"name":"手柄温度","range":"(0 – 200) °C"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648937","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 – 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 – 0,6) MPa","reference":"PN-EN 12809:2002 p. A.4.10 | PN-EN 16510-1:2018-08 p. A.4.10.5","norm_bases":["PN-EN 12809:2002 p. A.4.10","PN-EN 16510-1:2018-08 p. A.4.10.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW szczelność przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 12809:2002 p. A.4.10 | PN-EN 16510-1:2018-08 p. A.4.10.5 Kotly grzewcze na paliwa stale do 50 kW szczelnosc przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 12809:2002 p. A.4.10 | PN-EN 16510-1:2018-08 p. A.4.10.5","categories":["petro"],"row_index":348,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness of the water space","range":"(0,1 – 0,6) MPa"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) tightness of the water space PN-EN 12809:2002 p. A.4.10 | PN-EN 16510-1:2018-08 p. A.4.10.5","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 水腔密封性 PN-EN 12809:2002 p. A.4.10 | PN-EN 16510-1:2018-08 p. A.4.10.5","parameters_zh":[{"name":"水腔密封性","range":"(0,1 – 0,6) MPa"}],"test_object_zh":"50 kW 以下固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648938","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"","parameters":[{"name":"szczelność","range":"(0,016 – 2,6) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (0,016 – 2,6) m3/h","reference":"PN-EN 16510-1:2018-08 p. A.4.11.2","norm_bases":["PN-EN 16510-1:2018-08 p. A.4.11.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW szczelność (0,016 – 2,6) m3/h PN-EN 16510-1:2018-08 p. A.4.11.2 Kotly grzewcze na paliwa stale do 50 kW szczelnosc (0,016 – 2,6) m3/h PN-EN 16510-1:2018-08 p. A.4.11.2","categories":["petro"],"row_index":349,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness","range":"(0,016 – 2,6) m3/h"}],"search_en":"Heating boilers for solid fuels up to 50 kW Gas and Heating Appliances Testing Laboratory (GU-1) tightness PN-EN 16510-1:2018-08 p. A.4.11.2","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"50 kW 以下固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 密封性 PN-EN 16510-1:2018-08 p. A.4.11.2","test_object_zh":"50 kW 以下固体燃料供暖锅炉","parameters_zh":[{"name":"密封性","range":"(0,016 – 2,6) m3/h"}]},{"_id":"6a7d75f9441eff5f15648939","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe do 50 kW","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,01 – 1) g/m3"}],"technique":"Metoda: grawimetryczna","techniques":["Metoda: grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,01 – 1) g/m3\nMetoda: grawimetryczna","reference":"PN-EN 16510-1:2018-08 Załącznik F","norm_bases":["PN-EN 16510-1:2018-08 Załącznik F"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe do 50 kW Stężenie pyłów w spalinach\nZakres (0,01 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2018-08 Załącznik F Kotly grzewcze na paliwa stale do 50 kW Stezenie pylow w spalinach\nZakres (0,01 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2018-08 Zalacznik F","categories":["petro"],"row_index":350,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,01 – 1) g/m3"}],"search_en":"Heating boilers for solid fuels up to 50 kW Dust concentration in flue gases Method: gravimetric Gas and Heating Appliances Testing Laboratory (GU-1) Range PN-EN 16510-1:2018-08 Załącznik F","technique_en":"Method: gravimetric","test_object_en":"Heating boilers for solid fuels up to 50 kW","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","parameters_zh":[{"name":"范围","range":"(0,01 – 1) g/m3"}],"search_zh":"50 kW 以下固体燃料供暖锅炉 烟气中粉尘浓度 方法：重量法 燃气与供暖器具检测实验室（GU-1） 范围 PN-EN 16510-1:2018-08 Załącznik F","test_object_zh":"50 kW 以下固体燃料供暖锅炉","methodology_zh":"烟气中粉尘浓度","technique_zh":"方法：重量法"},{"_id":"6a7d75f9441eff5f1564893a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2018-08 Załącznik F","norm_bases":["PN-EN 16510-1:2018-08 Załącznik F"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY PALIWA: PN-EN 16510-1:2018-08 Załącznik F Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY PALIWA: PN-EN 16510-1:2018-08 Zalacznik F","categories":["petro"],"row_index":351,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FUEL PARAMETERS:","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding FUEL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2018-08 Załącznik F","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃料参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2018-08 Załącznik F","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"燃料参数："},{"_id":"6a7d75f9441eff5f1564893b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 – 20) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 – 20) kg","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego masa paliwa (0,1 – 20) kg PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":352,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"fuel mass","range":"(0,1 – 20) kg"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) fuel mass PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 燃料质量 PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"燃料质量","range":"(0,1 – 20) kg"}]},{"_id":"6a7d75f9441eff5f1564893c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 16510-1:2023-06 p. A.4.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY SPALIN: PN-EN 16510-1:2023-06 p. A.4.2","categories":["petro"],"row_index":353,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FLUE GAS PARAMETERS:","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding FLUE GAS PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 烟气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"烟气参数："},{"_id":"6a7d75f9441eff5f1564893d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 600) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-6:2023-06 p. 4.7.2, 4.7.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3","PN-EN 16510-2-6:2023-06 p. 4.7.2, 4.7.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-6:2023-06 p. 4.7.2, 4.7.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego temperatura (0 – 600) °C PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-6:2023-06 p. 4.7.2, 4.7.3 „N”","categories":["petro"],"row_index":354,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 600) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-6:2023-06 p. 4.7.2, 4.7.3 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 16510-1:2023-06 p. A.4.4.3 | PN-EN 16510-2-6:2023-06 p. 4.7.2, 4.7.3 „N”","parameters_zh":[{"name":"温度","range":"(0 – 600) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d75f9441eff5f1564893e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"ciśnienie","range":"(0,01 – 200) Pa;"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0,01 – 200) Pa;","reference":"PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.2.3.4; A.4","PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego ciśnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego cisnienie (0,01 – 200) Pa; PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N”","categories":["petro"],"row_index":355,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(0,01 – 200) Pa;"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 16510-1:2023-06 p. A.2.3.4; A.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N”","parameters_zh":[{"name":"压力","range":"(0,01 – 200) Pa;"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d75f9441eff5f1564893f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"Stężenia dwutlenku węgla, tlenku węgla, tlenu","parameters":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"Emisja CO (z obliczeń)"}],"technique":"Metoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda: PMD- paramagnetyczna","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","reference":"PN-EN 16510-2-6:2023-06 p. 4.3 „N”","norm_bases":["PN-EN 16510-2-6:2023-06 p. 4.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-2-6:2023-06 p. 4.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Stezenia dwutlenku wegla, tlenku wegla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczen)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 16510-2-6:2023-06 p. 4.3 „N”","categories":["petro","environment"],"row_index":356,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of carbon dioxide, carbon monoxide, oxygen","parameters_en":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO emission (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Concentrations of carbon dioxide, carbon monoxide, oxygen NDIR method; Method: PMD- paramagnetic; Electrochemical method Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2; CO; O2; O2; CO emission (calculated) PN-EN 16510-2-6:2023-06 p. 4.3 „N”","technique_en":"NDIR method; Method: PMD- paramagnetic; Electrochemical method","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 二氧化碳、一氧化碳、氧浓度 NDIR 法；PMD 顺磁法；电化学法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 CO 排放量（计算值） PN-EN 16510-2-6:2023-06 p. 4.3 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO 排放量（计算值）"}],"methodology_zh":"二氧化碳、一氧化碳、氧浓度","technique_zh":"NDIR 法；PMD 顺磁法；电化学法"},{"_id":"6a7d75f9441eff5f15648940","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.","parameters":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC","range":"(0,269 – 1288) mg org. C/m3"},{"name":"Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencja; Metoda FID","techniques":["Metoda chemiluminescencja","Metoda FID"],"computed":[],"activity":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC (0,269 – 1288) mg org. C/m3\nEmisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E","PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC (0,269 – 1288) mg org. C/m3\nEmisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Stezenia tlenku azotu, tlenkow azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC (0,269 – 1288) mg org. C/m3\nEmisja CO2; NO, NO2, NOx, OGC (z obliczen)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Zalacznik D, Zalacznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”","categories":["petro","environment"],"row_index":357,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.","parameters_en":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC","range":"(0,269 – 1288) mg org. C/m3"},{"name":"CO2; NO, NO2, NOx, OGC emission (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC. Chemiluminescence method; FID method Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. NO NOx OGC CO2; NO, NO2, NOx, OGC emission (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”","technique_en":"Chemiluminescence method; FID method","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。 化学发光法；FID 法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 NO NOx 总有机气态碳（OGC） CO2、NO、NO2、NOx、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”","parameters_zh":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"总有机气态碳（OGC）","range":"(0,269 – 1288) mg org. C/m3"},{"name":"CO2、NO、NO2、NOx、OGC 排放（由计算得出）"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。","technique_zh":"化学发光法；FID 法"},{"_id":"6a7d75f9441eff5f15648941","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E","PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Zalacznik D, Zalacznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”","categories":["petro"],"row_index":358,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"AIR PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding AIR PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 空气参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p.A.4.4.2, A.3 ,Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"空气参数："},{"_id":"6a7d75f9441eff5f15648942","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"temperatura","range":"(10 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 – 35) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego temperatura (10 – 35) °C PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro"],"row_index":359,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(10 – 35) °C"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.4.4.3","parameters_zh":[{"name":"温度","range":"(10 – 35) °C"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d75f9441eff5f15648943","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 p. A.4.4.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.4.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY WODY: PN-EN 16510-1:2023-06 p. A.4.4.3","categories":["petro","water"],"row_index":360,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"WATER PARAMETERS:","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding WATER PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 水参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.4.3","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"水参数："},{"_id":"6a7d75f9441eff5f15648944","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 100)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 100)°C","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego temperatura (0 – 100)°C PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego temperatura (0 – 100)°C PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":361,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 100)°C"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 16510-1:2023-06 p. A.4.5.2","parameters_zh":[{"name":"温度","range":"(0 – 100)°C"}],"test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d75f9441eff5f15648945","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"strumień objętości :","range":"(0,24 – 12) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości : (0,24 – 12) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego strumień objętości : (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego strumien objetosci : (0,24 – 12) m3/h PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":362,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"volume flow rate :","range":"(0,24 – 12) m3/h"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) volume flow rate : PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 体积流量： PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"体积流量：","range":"(0,24 – 12) m3/h"}]},{"_id":"6a7d75f9441eff5f15648946","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 16510-1:2023-06 p. A.4.5.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego BILANS CIEPLNY (z obliczeń): PN-EN 16510-1:2023-06 p. A.4.5.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego BILANS CIEPLNY (z obliczen): PN-EN 16510-1:2023-06 p. A.4.5.2","categories":["petro"],"row_index":363,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"HEAT BALANCE (calculated):","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding HEAT BALANCE (calculated): Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 热平衡（计算值）： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.4.5.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d75f9441eff5f15648947","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(5 – 60) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (5 – 60) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego moc cieplna doprowadzona z paliwem (5 – 60) kW PN-EN 16510-1:2023-06 p. A.6.2.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego moc cieplna doprowadzona z paliwem (5 – 60) kW PN-EN 16510-1:2023-06 p. A.6.2.2","categories":["petro"],"row_index":364,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat input from fuel","range":"(5 – 60) kW"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) heat input from fuel PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 燃料输入热功率 PN-EN 16510-1:2023-06 p. A.6.2.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"燃料输入热功率","range":"(5 – 60) kW"}]},{"_id":"6a7d75f9441eff5f15648948","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 – 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 – 40) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.2","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.6.2.1.2 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego strata kominowa (5 – 40) % PN-EN 16510-1:2023-06 p. A.6.2.1.2","categories":["petro"],"row_index":365,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"stack loss","range":"(5 – 40) %"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) stack loss PN-EN 16510-1:2023-06 p. A.6.2.1.2","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 排烟热损失 PN-EN 16510-1:2023-06 p. A.6.2.1.2","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"排烟热损失","range":"(5 – 40) %"}]},{"_id":"6a7d75f9441eff5f15648949","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.3","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego straty niezupełnego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.3 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego straty niezupelnego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.3","categories":["petro"],"row_index":366,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"losses due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) losses due to incomplete combustion PN-EN 16510-1:2023-06 p. A.6.2.1.3","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.6.2.1.3","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f1564894a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego strata niecałkowitego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego strata niecalkowitego spalania PN-EN 16510-1:2023-06 p. A.6.2.1.4","categories":["petro"],"row_index":367,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss due to incomplete combustion"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) loss due to incomplete combustion PN-EN 16510-1:2023-06 p. A.6.2.1.4","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 16510-1:2023-06 p. A.6.2.1.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f1564894b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 – 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 – 95) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego sprawność cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego sprawnosc cieplna (20 – 95) % PN-EN 16510-1:2023-06 p. A.6.2.1","categories":["petro"],"row_index":368,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal efficiency","range":"(20 – 95) %"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) thermal efficiency PN-EN 16510-1:2023-06 p. A.6.2.1","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 热效率 PN-EN 16510-1:2023-06 p. A.6.2.1","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"热效率","range":"(20 – 95) %"}]},{"_id":"6a7d75f9441eff5f1564894c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"łączna moc cieplna","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"łączna moc cieplna (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.2","PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego łączna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego laczna moc cieplna (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N”","categories":["petro"],"row_index":369,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"total heat output","range":"(3 – 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. total heat output PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 总热功率 PN-EN 16510-1:2023-06 p. A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"总热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f1564894d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"moc cieplna obiegu wodnego","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna obiegu wodnego (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.3","PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego moc cieplna obiegu wodnego (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego moc cieplna obiegu wodnego (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N”","categories":["petro"],"row_index":370,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output of the water circuit","range":"(3 – 50) kW"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output of the water circuit PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水循环回路热功率 PN-EN 16510-1:2023-06 p. A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"水循环回路热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f1564894e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"moc cieplna oddawana do pomieszczenia","range":"(3 – 50) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna oddawana do pomieszczenia (3 – 50) kW","reference":"PN-EN 16510-1:2023-06 p. A.6.2.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego moc cieplna oddawana do pomieszczenia (3 – 50) kW PN-EN 16510-1:2023-06 p. A.6.2.4","categories":["petro"],"row_index":371,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output to the room","range":"(3 – 50) kW"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) heat output to the room PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 向房间输出的热功率 PN-EN 16510-1:2023-06 p. A.6.2.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"向房间输出的热功率","range":"(3 – 50) kW"}]},{"_id":"6a7d75f9441eff5f1564894f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(5 – 100) g/s"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy spalin (5 – 100) g/s","reference":"PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.5","PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego strumień masy spalin (5 – 100) g/s PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego strumien masy spalin (5 – 100) g/s PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N”","categories":["petro"],"row_index":372,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"flue gas mass flow","range":"(5 – 100) g/s"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 PN-EN 16510-1:2023-06 p. A.6.2.5 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"烟气质量流量","range":"(5 – 100) g/s"}]},{"_id":"6a7d75f9441eff5f15648950","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"zawartość CO (O2=13 %)","range":"(0,001 – 0,5) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13 %) (0,001 – 0,5) %","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego zawartość CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego zawartosc CO (O2=13 %) (0,001 – 0,5) % PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":373,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"CO content (O2=13 %)","range":"(0,001 – 0,5) %"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) CO content (O2=13 %) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） CO 含量（O2=13 %） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"CO 含量（O2=13 %）","range":"(0,001 – 0,5) %"}]},{"_id":"6a7d75f9441eff5f15648951","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 16510-1:2023-06 p. A.6.2.6","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 16510-1:2023-06 p. A.6.2.6","categories":["petro"],"row_index":374,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding TECHNICAL AND OPERATIONAL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 技术与运行参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p. A.6.2.6","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"技术与运行参数："},{"_id":"6a7d75f9441eff5f15648952","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 – 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 – 200) °C"},{"name":"temperatura uchwytów","range":"(0 – 300) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 300) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.7, A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.7, A.4.8, A.4.9, A.4.10","PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7, A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\ntemperatura naroznika pomiarowego i podloza (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytow (0 – 300) °C PN-EN 16510-1:2023-06 p. A.4.7, A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N”","categories":["petro"],"row_index":375,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 – 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 – 200) °C"},{"name":"temperature of handles","range":"(0 – 300) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 16510-1:2023-06 p. A.4.7, A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 16510-1:2023-06 p. A.4.7, A.4.8, A.4.9, A.4.10 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 – 200) °C"},{"name":"燃料储斗温度","range":"(0 – 200) °C"},{"name":"手柄温度","range":"(0 – 300) °C"}]},{"_id":"6a7d75f9441eff5f15648953","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"szczelność przestrzeni wodnej","range":"(0,1 – 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność przestrzeni wodnej (0,1 – 0,6) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.6","PN-EN 16510-2-6:2023-06 p. 5.3.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego szczelność przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego szczelnosc przestrzeni wodnej (0,1 – 0,6) MPa PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N”","categories":["petro"],"row_index":376,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness of the water space","range":"(0,1 – 0,6) MPa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness of the water space PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 水腔密封性 PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"水腔密封性","range":"(0,1 – 0,6) MPa"}]},{"_id":"6a7d75f9441eff5f15648954","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"termiczne zabezpieczenie odpływu temperatura wody","range":"(0 – 120) °C"},{"name":"ciśnienie wody","range":"(0,1 – 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\ntermiczne zabezpieczenie odpływu temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.7 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\ntermiczne zabezpieczenie odplywu temperatura wody (0 – 120) °C\ncisnienie wody (0,1 – 0,3) MPa PN-EN 16510-1:2023-06 p. A.4.10.7","categories":["petro","water"],"row_index":377,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal outlet safety device water temperature","range":"(0 – 120) °C"},{"name":"water pressure","range":"(0,1 – 0,3) MPa"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) thermal outlet safety device water temperature water pressure PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 出水热保护 水温 水压 PN-EN 16510-1:2023-06 p. A.4.10.7","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"出水热保护 水温","range":"(0 – 120) °C"},{"name":"水压","range":"(0,1 – 0,3) MPa"}]},{"_id":"6a7d75f9441eff5f15648955","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"szczelność","range":"(0,016 – 2,6) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność (0,016 – 2,6) m3/h","reference":"PN-EN 16510-1:2023-06 p. A.4.11.2 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.11.2","PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego szczelność (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego szczelnosc (0,016 – 2,6) m3/h PN-EN 16510-1:2023-06 p. A.4.11.2 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N”","categories":["petro"],"row_index":378,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness","range":"(0,016 – 2,6) m3/h"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. tightness PN-EN 16510-1:2023-06 p. A.4.11.2 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 密封性 PN-EN 16510-1:2023-06 p. A.4.11.2 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"密封性","range":"(0,016 – 2,6) m3/h"}]},{"_id":"6a7d75f9441eff5f15648956","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"szczelność związana z emisją CO (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"szczelność związana z emisją CO (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p. 5.9.1","norm_bases":["PN-EN 16510-1:2023-06 p. 5.9.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego szczelność związana z emisją CO (z obliczeń) PN-EN 16510-1:2023-06 p. 5.9.1 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego szczelnosc zwiazana z emisja CO (z obliczen) PN-EN 16510-1:2023-06 p. 5.9.1","categories":["petro"],"row_index":379,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"tightness related to CO emission (calculated)"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) tightness related to CO emission (calculated) PN-EN 16510-1:2023-06 p. 5.9.1","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 与 CO 排放相关的密封性（由计算得出） PN-EN 16510-1:2023-06 p. 5.9.1","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"与 CO 排放相关的密封性（由计算得出）"}]},{"_id":"6a7d75f9441eff5f15648957","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"pomiar zużycia energii elektrycznej","range":"(1 – 1500) W,"},{"name":"metoda: przetworników mocy"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\npomiar zużycia energii elektrycznej (1 – 1500) W,\nmetoda: przetworników mocy","reference":"PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. 6.11","PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\npomiar zużycia energii elektrycznej (1 – 1500) W,\nmetoda: przetworników mocy PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\npomiar zuzycia energii elektrycznej (1 – 1500) W,\nmetoda: przetwornikow mocy PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N”","categories":["petro"],"row_index":380,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"measurement of electrical energy consumption","range":"(1 – 1500) W,"},{"name":"method: power transducers"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. measurement of electrical energy consumption method: power transducers PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 电能消耗测量 方法：功率传感器 PN-EN 16510-1:2023-06 p. 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"电能消耗测量","range":"(1 – 1500) W,"},{"name":"方法：功率传感器"}]},{"_id":"6a7d75f9441eff5f15648958","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"próba bezpieczeństwa temperaturowego"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa temperaturowego","reference":"PN-EN 16510-1:2023-06 p. A.4.10.4","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego próba bezpieczeństwa temperaturowego PN-EN 16510-1:2023-06 p. A.4.10.4 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego proba bezpieczenstwa temperaturowego PN-EN 16510-1:2023-06 p. A.4.10.4","categories":["petro"],"row_index":381,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature safety test"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) temperature safety test PN-EN 16510-1:2023-06 p. A.4.10.4","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 温度安全性试验 PN-EN 16510-1:2023-06 p. A.4.10.4","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"温度安全性试验"}]},{"_id":"6a7d75f9441eff5f15648959","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"próba bezpieczeństwa przy ciągu naturalnym"}],"technique":null,"techniques":[],"computed":[],"activity":"próba bezpieczeństwa przy ciągu naturalnym","reference":"PN-EN 16510-1:2023-06 p. A.4.10.5","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.5"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego próba bezpieczeństwa przy ciągu naturalnym PN-EN 16510-1:2023-06 p. A.4.10.5 Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego proba bezpieczenstwa przy ciagu naturalnym PN-EN 16510-1:2023-06 p. A.4.10.5","categories":["petro"],"row_index":382,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"safety test under natural draught"}],"search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) safety test under natural draught PN-EN 16510-1:2023-06 p. A.4.10.5","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） 自然通风条件下的安全试验 PN-EN 16510-1:2023-06 p. A.4.10.5","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"自然通风条件下的安全试验"}]},{"_id":"6a7d75f9441eff5f1564895a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"działanie ogranicznika temperatury bezpieczeństwa","range":"(0 – 110) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"działanie ogranicznika temperatury bezpieczeństwa (0 – 110) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.1 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7","PN-EN 16510-2-6:2023-06 p. A.4.10.601.1 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego działanie ogranicznika temperatury bezpieczeństwa (0 – 110) °C PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.1 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego dzialanie ogranicznika temperatury bezpieczenstwa (0 – 110) °C PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.1 „N”","categories":["petro"],"row_index":383,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"operation of the safety temperature limiter","range":"(0 – 110) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. operation of the safety temperature limiter PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.1 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 安全温度限制器的动作 PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.1 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"安全温度限制器的动作","range":"(0 – 110) °C"}]},{"_id":"6a7d75f9441eff5f1564895b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"zanik zasilania elektrycznego","range":"(0 – 110) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"zanik zasilania elektrycznego (0 – 110) °C","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.2 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7","PN-EN 16510-2-6:2023-06 p. A.4.10.601.2 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego zanik zasilania elektrycznego (0 – 110) °C PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.2 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego zanik zasilania elektrycznego (0 – 110) °C PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.2 „N”","categories":["petro"],"row_index":384,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss of electrical power supply","range":"(0 – 110) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. loss of electrical power supply PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.2 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 供电中断 PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.2 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"供电中断","range":"(0 – 110) °C"}]},{"_id":"6a7d75f9441eff5f1564895c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"zanik odbioru ciepła","range":"(0 – 110) °C,"},{"name":"(0 – 5) % CO"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nzanik odbioru ciepła (0 – 110) °C,\n(0 – 5) % CO","reference":"PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.3 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.4.10.7","PN-EN 16510-2-6:2023-06 p. A.4.10.601.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\nzanik odbioru ciepła (0 – 110) °C,\n(0 – 5) % CO PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.3 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\nzanik odbioru ciepla (0 – 110) °C,\n(0 – 5) % CO PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.3 „N”","categories":["petro"],"row_index":385,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss of heat dissipation","range":"(0 – 110) °C,"},{"name":"(0 – 5) % CO"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. loss of heat dissipation (0 – 5) % CO PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.3 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 p. A.4.10.7 | PN-EN 16510-2-6:2023-06 p. A.4.10.601.3 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料"},{"_id":"6a7d75f9441eff5f1564895d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"","parameters":[{"name":"efektywność (z obliczeń)"},{"name":"sezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)"},{"name":"wskaźnik efektywności energetycznej EEI (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)\nwskaźnik efektywności energetycznej EEI (z obliczeń)","reference":"PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6 | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N”","norm_bases":["PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6","PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\nefektywność (z obliczeń)\nsezonowa efektywność energetyczna ogrzewania pomieszczeń (z obliczeń)\nwskaźnik efektywności energetycznej EEI (z obliczeń) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6 | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Zakres:\nefektywnosc (z obliczen)\nsezonowa efektywnosc energetyczna ogrzewania pomieszczen (z obliczen)\nwskaznik efektywnosci energetycznej EEI (z obliczen) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6 | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N”","categories":["petro"],"row_index":386,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"efficiency (calculated)"},{"name":"seasonal space heating energy efficiency (calculated)"},{"name":"energy efficiency index EEI (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. efficiency (calculated) seasonal space heating energy efficiency (calculated) energy efficiency index EEI (calculated) PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6 | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N”","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 效率（由计算得出） 供暖季房间采暖能效（由计算得出） 能效指数 EEI（由计算得出） PN-EN 16510-1:2023-06 p. A.6.2.1.5, A.6.2.1.6 | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","parameters_zh":[{"name":"效率（由计算得出）"},{"name":"供暖季房间采暖能效（由计算得出）"},{"name":"能效指数 EEI（由计算得出）"}]},{"_id":"6a7d75f9441eff5f1564895e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,003 – 1) g/m3"}],"technique":"Metoda: grawimetryczna","techniques":["Metoda: grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna","reference":"PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F","PN-EN 16510-2-6:2023-06 p. 4.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Mieszkaniowe urządzenia spalające paliwo stałe - Ogrzewacze pokojowe, urządzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N” Mieszkaniowe urzadzenia spalajace paliwo stale - Ogrzewacze pokojowe, urzadzenia zabudowane i kuchenki z mechanicznym podawaniem pelletu drzewnego Stezenie pylow w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Zalacznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”","categories":["petro"],"row_index":387,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,003 – 1) g/m3"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding Dust concentration in flue gases Method: gravimetric Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”","technique_en":"Method: gravimetric","test_object_en":"Residential solid fuel burning appliances - Roomheaters, inset appliances and cookers with mechanical wood pellet feeding","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","parameters_zh":[{"name":"范围","range":"(0,003 – 1) g/m3"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料 烟气中粉尘浓度 方法：重量法 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”","test_object_zh":"民用固体燃料燃烧器具 — 房间加热器、嵌入式器具及炊具，带木质颗粒机械给料","methodology_zh":"烟气中粉尘浓度","technique_zh":"方法：重量法"},{"_id":"6a7d75f9441eff5f1564895f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F","PN-EN 16510-2-6:2023-06 p. 4.6 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N” Akumulacyjne ogrzewacze pomieszczen na paliwa stale PARAMETRY PALIWA: PN-EN 16510-1:2023-06 Zalacznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”","categories":["petro"],"row_index":388,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FUEL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters FUEL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃料参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 16510-1:2023-06 Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N”","methodology_zh":"燃料参数：","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648960","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"masa paliwa","range":"(0,1 – 20) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"masa paliwa (0,1 – 20) kg","reference":"PN-EN 15250:2009 A3; A4.2 „N”","norm_bases":["PN-EN 15250:2009 A3; A4.2 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe masa paliwa (0,1 – 20) kg PN-EN 15250:2009 A3; A4.2 „N” Akumulacyjne ogrzewacze pomieszczen na paliwa stale masa paliwa (0,1 – 20) kg PN-EN 15250:2009 A3; A4.2 „N”","categories":["petro"],"row_index":389,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"fuel mass","range":"(0,1 – 20) kg"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. fuel mass PN-EN 15250:2009 A3; A4.2 „N”","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 燃料质量 PN-EN 15250:2009 A3; A4.2 „N”","parameters_zh":[{"name":"燃料质量","range":"(0,1 – 20) kg"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648961","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 15250:2009 A3; A4.2 „N”","norm_bases":["PN-EN 15250:2009 A3; A4.2 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe PARAMETRY SPALIN: PN-EN 15250:2009 A3; A4.2 „N” Akumulacyjne ogrzewacze pomieszczen na paliwa stale PARAMETRY SPALIN: PN-EN 15250:2009 A3; A4.2 „N”","categories":["petro"],"row_index":390,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FLUE GAS PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters FLUE GAS PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 15250:2009 A3; A4.2 „N”","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 烟气参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 15250:2009 A3; A4.2 „N”","methodology_zh":"烟气参数：","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648962","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 600) °C","reference":"PN-EN 15250:2009 p. A.2.3.2; A.4.4.3 „N”","norm_bases":["PN-EN 15250:2009 p. A.2.3.2; A.4.4.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe temperatura (0 – 600) °C PN-EN 15250:2009 p. A.2.3.2; A.4.4.3 „N” Akumulacyjne ogrzewacze pomieszczen na paliwa stale temperatura (0 – 600) °C PN-EN 15250:2009 p. A.2.3.2; A.4.4.3 „N”","categories":["petro"],"row_index":391,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 600) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 15250:2009 p. A.2.3.2; A.4.4.3 „N”","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 15250:2009 p. A.2.3.2; A.4.4.3 „N”","parameters_zh":[{"name":"温度","range":"(0 – 600) °C"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648963","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"ciśnienie","range":"(0,01 – 250) Pa;"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0,01 – 250) Pa;","reference":"PN-EN 15250:2009 p. A.2.3.4; A.4 „N”","norm_bases":["PN-EN 15250:2009 p. A.2.3.4; A.4 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe ciśnienie (0,01 – 250) Pa; PN-EN 15250:2009 p. A.2.3.4; A.4 „N” Akumulacyjne ogrzewacze pomieszczen na paliwa stale cisnienie (0,01 – 250) Pa; PN-EN 15250:2009 p. A.2.3.4; A.4 „N”","categories":["petro"],"row_index":392,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(0,01 – 250) Pa;"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. pressure PN-EN 15250:2009 p. A.2.3.4; A.4 „N”","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 压力 PN-EN 15250:2009 p. A.2.3.4; A.4 „N”","parameters_zh":[{"name":"压力","range":"(0,01 – 250) Pa;"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648964","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"Stężenia dwutlenku węgla, tlenku węgla, tlenu","parameters":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"Emisja CO (z obliczeń)"}],"technique":"Metoda NDIR; Metoda: PMD - paramagnetyczna; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda: PMD - paramagnetyczna","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD - paramagnetyczna; Metoda elektrochemiczna","reference":"PN-EN 15250:2009 p. A.2.3.3; A.4.4.2 „N”","norm_bases":["PN-EN 15250:2009 p. A.2.3.3; A.4.4.2 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD - paramagnetyczna; Metoda elektrochemiczna PN-EN 15250:2009 p. A.2.3.3; A.4.4.2 „N” Akumulacyjne ogrzewacze pomieszczen na paliwa stale Stezenia dwutlenku wegla, tlenku wegla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,5) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczen)\nMetoda NDIR; Metoda: PMD - paramagnetyczna; Metoda elektrochemiczna PN-EN 15250:2009 p. A.2.3.3; A.4.4.2 „N”","categories":["environment","petro"],"row_index":393,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of carbon dioxide, carbon monoxide, oxygen","parameters_en":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO emission (calculated)"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Concentrations of carbon dioxide, carbon monoxide, oxygen NDIR method; Method: PMD - paramagnetic; Electrochemical method Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO2; CO; O2; O2; CO emission (calculated) PN-EN 15250:2009 p. A.2.3.3; A.4.4.2 „N”","technique_en":"NDIR method; Method: PMD - paramagnetic; Electrochemical method","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 二氧化碳、一氧化碳、氧浓度 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 CO 排放量（计算值） PN-EN 15250:2009 p. A.2.3.3; A.4.4.2 „N”","parameters_zh":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,5) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO 排放量（计算值）"}],"test_object_zh":"固体燃料蓄热式房间加热器","methodology_zh":"二氧化碳、一氧化碳、氧浓度"},{"_id":"6a7d75f9441eff5f15648965","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.","parameters":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"technique":"Metoda chemiluminescencja; Metoda FID","techniques":["Metoda chemiluminescencja","Metoda FID"],"computed":[],"activity":"Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe Stężenia tlenku azotu, tlenków azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E Akumulacyjne ogrzewacze pomieszczen na paliwa stale Stezenia tlenku azotu, tlenkow azotu (NO, NOx), OGC.\nZakres:\nNO (0,5 – 200) ppm\nNOx (0,5 – 200) ppm\nOGC; (0,269 –1288) mg org. C/m3 Emisja CO2; NO, NO2, NOx, OGC (z obliczen)\nMetoda chemiluminescencja; Metoda FID PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E","categories":["environment","petro"],"row_index":394,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC.","parameters_en":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC; (0,269 –1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated)"}],"search_en":"Solid fuel heat storage local space heaters Concentrations of nitrogen monoxide, nitrogen oxides (NO, NOx), OGC. Chemiluminescence method; FID method Gas and Heating Appliances Testing Laboratory (GU-1) NO NOx OGC; (0,269 –1288) mg org. C/m3 CO2; NO, NO2, NOx, OGC emission (calculated) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","technique_en":"Chemiluminescence method; FID method","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料蓄热式房间加热器 一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。 化学发光法；FID 法 燃气与供暖器具检测实验室（GU-1） NO NOx OGC；(0,269 –1288) mg 有机 C/m3；CO2、NO、NO2、NOx、OGC 排放（由计算得出） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","parameters_zh":[{"name":"NO","range":"(0,5 – 200) ppm"},{"name":"NOx","range":"(0,5 – 200) ppm"},{"name":"OGC；(0,269 –1288) mg 有机 C/m3；CO2、NO、NO2、NOx、OGC 排放（由计算得出）"}],"test_object_zh":"固体燃料蓄热式房间加热器","methodology_zh":"一氧化氮、氮氧化物（NO、NOx）、总有机气态碳（OGC）浓度。","technique_zh":"化学发光法；FID 法"},{"_id":"6a7d75f9441eff5f15648966","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"PARAMETRY POWIETRZA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA:","reference":"PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","norm_bases":["PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E Akumulacyjne ogrzewacze pomieszczen na paliwa stale PARAMETRY POWIETRZA: PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Zalacznik D, Zalacznik E","categories":["petro"],"row_index":395,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"AIR PARAMETERS:","search_en":"Solid fuel heat storage local space heaters AIR PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料蓄热式房间加热器 空气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E","methodology_zh":"空气参数：","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648967","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"temperatura","range":"(10 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 – 35) °C","reference":"PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”","norm_bases":["PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe temperatura (10 – 35) °C PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N” Akumulacyjne ogrzewacze pomieszczen na paliwa stale temperatura (10 – 35) °C PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”","categories":["petro"],"row_index":396,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(10 – 35) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 温度 PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”","parameters_zh":[{"name":"温度","range":"(10 – 35) °C"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648968","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”","norm_bases":["PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe BILANS CIEPLNY (z obliczeń): PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N” Akumulacyjne ogrzewacze pomieszczen na paliwa stale BILANS CIEPLNY (z obliczen): PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”","categories":["petro"],"row_index":397,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"HEAT BALANCE (calculated):","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters HEAT BALANCE (calculated): Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 热平衡（计算值）： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 15250:2009 p. A.1.1; A.4.4.3 „N”","methodology_zh":"热平衡（计算值）：","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648969","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"energia cieplna doprowadzona z paliwem","range":"(10 – 600) MJ"}],"technique":null,"techniques":[],"computed":[],"activity":"energia cieplna doprowadzona z paliwem (10 – 600) MJ","reference":"PN-EN 15250:2009 p. A.6.2.2 „N”","norm_bases":["PN-EN 15250:2009 p. A.6.2.2 „N”"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe energia cieplna doprowadzona z paliwem (10 – 600) MJ PN-EN 15250:2009 p. A.6.2.2 „N” Akumulacyjne ogrzewacze pomieszczen na paliwa stale energia cieplna doprowadzona z paliwem (10 – 600) MJ PN-EN 15250:2009 p. A.6.2.2 „N”","categories":["petro"],"row_index":398,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat energy supplied with the fuel","range":"(10 – 600) MJ"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat energy supplied with the fuel PN-EN 15250:2009 p. A.6.2.2 „N”","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 15250:2009 p. A.6.2.2 „N”","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f1564896a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 – 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 – 40) %","reference":"PN-EN 15250:2009 p. A.6.2.1.2„N“","norm_bases":["PN-EN 15250:2009 p. A.6.2.1.2„N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe strata kominowa (5 – 40) % PN-EN 15250:2009 p. A.6.2.1.2„N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale strata kominowa (5 – 40) % PN-EN 15250:2009 p. A.6.2.1.2„N“","categories":["petro"],"row_index":399,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"stack loss","range":"(5 – 40) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. stack loss PN-EN 15250:2009 p. A.6.2.1.2„N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 排烟热损失 PN-EN 15250:2009 p. A.6.2.1.2„N“","parameters_zh":[{"name":"排烟热损失","range":"(5 – 40) %"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f1564896b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 15250:2009 p. A.6.2.1.3„N“","norm_bases":["PN-EN 15250:2009 p. A.6.2.1.3„N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe straty niezupełnego spalania PN-EN 15250:2009 p. A.6.2.1.3„N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale straty niezupelnego spalania PN-EN 15250:2009 p. A.6.2.1.3„N“","categories":["petro"],"row_index":400,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"losses due to incomplete combustion"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. losses due to incomplete combustion PN-EN 15250:2009 p. A.6.2.1.3„N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 不完全燃烧损失 PN-EN 15250:2009 p. A.6.2.1.3„N“","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f1564896c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"strata niecałkowitego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania","reference":"PN-EN 15250:2009 p. A.6.2.1.4„N“","norm_bases":["PN-EN 15250:2009 p. A.6.2.1.4„N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe strata niecałkowitego spalania PN-EN 15250:2009 p. A.6.2.1.4„N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale strata niecalkowitego spalania PN-EN 15250:2009 p. A.6.2.1.4„N“","categories":["petro"],"row_index":401,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss due to incomplete combustion"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. loss due to incomplete combustion PN-EN 15250:2009 p. A.6.2.1.4„N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 不完全燃烧损失 PN-EN 15250:2009 p. A.6.2.1.4„N“","parameters_zh":[{"name":"不完全燃烧损失"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f1564896d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 – 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 – 95) %","reference":"PN-EN 15250:2009 p. A.6.2.1.1„N“","norm_bases":["PN-EN 15250:2009 p. A.6.2.1.1„N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe sprawność cieplna (20 – 95) % PN-EN 15250:2009 p. A.6.2.1.1„N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale sprawnosc cieplna (20 – 95) % PN-EN 15250:2009 p. A.6.2.1.1„N“","categories":["petro"],"row_index":402,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal efficiency","range":"(20 – 95) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. thermal efficiency PN-EN 15250:2009 p. A.6.2.1.1„N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 热效率 PN-EN 15250:2009 p. A.6.2.1.1„N“","parameters_zh":[{"name":"热效率","range":"(20 – 95) %"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f1564896e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"wydajność cieplna","range":"(10 – 600) MJ"}],"technique":null,"techniques":[],"computed":[],"activity":"wydajność cieplna (10 – 600) MJ","reference":"PN-EN 15250:2009 p. A.6.2.2 „N“","norm_bases":["PN-EN 15250:2009 p. A.6.2.2 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe wydajność cieplna (10 – 600) MJ PN-EN 15250:2009 p. A.6.2.2 „N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale wydajnosc cieplna (10 – 600) MJ PN-EN 15250:2009 p. A.6.2.2 „N“","categories":["petro"],"row_index":403,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output","range":"(10 – 600) MJ"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. heat output PN-EN 15250:2009 p. A.6.2.2 „N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 15250:2009 p. A.6.2.2 „N“","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f1564896f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"strumień masy spalin","range":"(5 – 100) g/s"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy spalin (5 – 100) g/s","reference":"PN-EN 15250:2009 p. A.6.2.3 „N“","norm_bases":["PN-EN 15250:2009 p. A.6.2.3 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe strumień masy spalin (5 – 100) g/s PN-EN 15250:2009 p. A.6.2.3 „N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale strumien masy spalin (5 – 100) g/s PN-EN 15250:2009 p. A.6.2.3 „N“","categories":["petro"],"row_index":404,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"flue gas mass flow","range":"(5 – 100) g/s"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. flue gas mass flow PN-EN 15250:2009 p. A.6.2.3 „N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 烟气质量流量 PN-EN 15250:2009 p. A.6.2.3 „N“","test_object_zh":"固体燃料蓄热式房间加热器","parameters_zh":[{"name":"烟气质量流量","range":"(5 – 100) g/s"}]},{"_id":"6a7d75f9441eff5f15648970","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"zawartość CO (O2=13 %)","range":"(0,001 – 0,5) %"}],"technique":null,"techniques":[],"computed":[],"activity":"zawartość CO (O2=13 %) (0,001 – 0,5) %","reference":"PN-EN 15250:2009 p. A.6.2.4 „N“","norm_bases":["PN-EN 15250:2009 p. A.6.2.4 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe zawartość CO (O2=13 %) (0,001 – 0,5) % PN-EN 15250:2009 p. A.6.2.4 „N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale zawartosc CO (O2=13 %) (0,001 – 0,5) % PN-EN 15250:2009 p. A.6.2.4 „N“","categories":["petro"],"row_index":405,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"CO content (O2=13 %)","range":"(0,001 – 0,5) %"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. CO content (O2=13 %) PN-EN 15250:2009 p. A.6.2.4 „N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 CO 含量（O2=13 %） PN-EN 15250:2009 p. A.6.2.4 „N“","test_object_zh":"固体燃料蓄热式房间加热器","parameters_zh":[{"name":"CO 含量（O2=13 %）","range":"(0,001 – 0,5) %"}]},{"_id":"6a7d75f9441eff5f15648971","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"średnia różnica temperatury powierzchni ogrzewacza i otoczenia","range":"(0 – 200) K"}],"technique":null,"techniques":[],"computed":[],"activity":"średnia różnica temperatury powierzchni ogrzewacza i otoczenia (0 – 200) K","reference":"PN-EN 15250:2009 p. A.6.2.7 „N“","norm_bases":["PN-EN 15250:2009 p. A.6.2.7 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe średnia różnica temperatury powierzchni ogrzewacza i otoczenia (0 – 200) K PN-EN 15250:2009 p. A.6.2.7 „N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale srednia roznica temperatury powierzchni ogrzewacza i otoczenia (0 – 200) K PN-EN 15250:2009 p. A.6.2.7 „N“","categories":["petro"],"row_index":406,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"mean temperature difference between the heater surface and the surroundings","range":"(0 – 200) K"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. mean temperature difference between the heater surface and the surroundings PN-EN 15250:2009 p. A.6.2.7 „N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 15250:2009 p. A.6.2.7 „N“","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648972","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE:","reference":"PN-EN 15250:2009 p. A.6.2.7 „N“","norm_bases":["PN-EN 15250:2009 p. A.6.2.7 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 15250:2009 p. A.6.2.7 „N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale PARAMETRY TECHNICZNO - EKSPLOATACYJNE: PN-EN 15250:2009 p. A.6.2.7 „N“","categories":["petro"],"row_index":407,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS:","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters TECHNICAL AND OPERATIONAL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 15250:2009 p. A.6.2.7 „N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 技术与运行参数： 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 15250:2009 p. A.6.2.7 „N“","test_object_zh":"固体燃料蓄热式房间加热器","methodology_zh":"技术与运行参数："},{"_id":"6a7d75f9441eff5f15648973","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"temperatura powierzchni akumulacyjnego ogrzewacza","range":"(0 – 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura powierzchni akumulacyjnego ogrzewacza (0 – 200) °C","reference":"PN-EN 15250:2009 p. A.2.5; A.4.6 „N“","norm_bases":["PN-EN 15250:2009 p. A.2.5; A.4.6 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe temperatura powierzchni akumulacyjnego ogrzewacza (0 – 200) °C PN-EN 15250:2009 p. A.2.5; A.4.6 „N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale temperatura powierzchni akumulacyjnego ogrzewacza (0 – 200) °C PN-EN 15250:2009 p. A.2.5; A.4.6 „N“","categories":["petro"],"row_index":408,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"surface temperature of the storage heater","range":"(0 – 200) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. surface temperature of the storage heater PN-EN 15250:2009 p. A.2.5; A.4.6 „N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 15250:2009 p. A.2.5; A.4.6 „N“","test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648974","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"","parameters":[{"name":"temperatura narożnika pomiarowego i podłoża","range":"(0 – 200) °C"},{"name":"temperatura zasobnika paliwa","range":"(0 – 200) °C"},{"name":"temperatura uchwytów","range":"(0 – 300) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 300) °C","reference":"PN-EN 15250:2009 p. A.2.2; A.4.6; A.4.7 „N“","norm_bases":["PN-EN 15250:2009 p. A.2.2; A.4.6; A.4.7 „N“"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe Zakres:\ntemperatura narożnika pomiarowego i podłoża (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytów (0 – 300) °C PN-EN 15250:2009 p. A.2.2; A.4.6; A.4.7 „N“ Akumulacyjne ogrzewacze pomieszczen na paliwa stale Zakres:\ntemperatura naroznika pomiarowego i podloza (0 – 200) °C\ntemperatura zasobnika paliwa (0 – 200) °C\ntemperatura uchwytow (0 – 300) °C PN-EN 15250:2009 p. A.2.2; A.4.6; A.4.7 „N“","categories":["petro"],"row_index":409,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature of the measuring corner and the floor","range":"(0 – 200) °C"},{"name":"temperature of the fuel hopper","range":"(0 – 200) °C"},{"name":"temperature of handles","range":"(0 – 300) °C"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Solid fuel heat storage local space heaters Gas and Heating Appliances Testing Laboratory (GU-1) „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. temperature of the measuring corner and the floor temperature of the fuel hopper temperature of handles PN-EN 15250:2009 p. A.2.2; A.4.6; A.4.7 „N“","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"固体燃料蓄热式房间加热器 燃气与供暖器具检测实验室（GU-1） “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 测量角与地面的温度 燃料储斗温度 手柄温度 PN-EN 15250:2009 p. A.2.2; A.4.6; A.4.7 „N“","parameters_zh":[{"name":"测量角与地面的温度","range":"(0 – 200) °C"},{"name":"燃料储斗温度","range":"(0 – 200) °C"},{"name":"手柄温度","range":"(0 – 300) °C"}],"test_object_zh":"固体燃料蓄热式房间加热器"},{"_id":"6a7d75f9441eff5f15648975","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,003 – 1) g/m3"}],"technique":"Metoda: grawimetryczna","techniques":["Metoda: grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna","reference":"PN-EN 16510-1:2023-06 Załącznik F","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Akumulacyjne ogrzewacze pomieszczeń na paliwa stałe Stężenie pyłów w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Załącznik F Akumulacyjne ogrzewacze pomieszczen na paliwa stale Stezenie pylow w spalinach\nZakres (0,003 – 1) g/m3\nMetoda: grawimetryczna PN-EN 16510-1:2023-06 Zalacznik F","categories":["petro"],"row_index":410,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,003 – 1) g/m3"}],"search_en":"Solid fuel heat storage local space heaters Dust concentration in flue gases Method: gravimetric Gas and Heating Appliances Testing Laboratory (GU-1) Range PN-EN 16510-1:2023-06 Załącznik F","technique_en":"Method: gravimetric","test_object_en":"Solid fuel heat storage local space heaters","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","parameters_zh":[{"name":"范围","range":"(0,003 – 1) g/m3"}],"search_zh":"固体燃料蓄热式房间加热器 烟气中粉尘浓度 方法：重量法 燃气与供暖器具检测实验室（GU-1） 范围 PN-EN 16510-1:2023-06 Załącznik F","test_object_zh":"固体燃料蓄热式房间加热器","methodology_zh":"烟气中粉尘浓度","technique_zh":"方法：重量法"},{"_id":"6a7d75f9441eff5f15648976","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"PARAMETRY WODY:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY WODY:","reference":"PN-EN 16510-1:2023-06 Załącznik F","norm_bases":["PN-EN 16510-1:2023-06 Załącznik F"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe PARAMETRY WODY: PN-EN 16510-1:2023-06 Załącznik F Kotly grzewcze na paliwa stale PARAMETRY WODY: PN-EN 16510-1:2023-06 Zalacznik F","categories":["water","petro"],"row_index":411,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"WATER PARAMETERS:","search_en":"Heating boilers for solid fuels WATER PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 16510-1:2023-06 Załącznik F","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 水参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 16510-1:2023-06 Załącznik F","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"水参数："},{"_id":"6a7d75f9441eff5f15648977","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 100) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 100) °C","reference":"PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2","norm_bases":["PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe temperatura (0 – 100) °C PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2 Kotly grzewcze na paliwa stale temperatura (0 – 100) °C PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2","categories":["petro"],"row_index":412,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 100) °C"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2","parameters_zh":[{"name":"温度","range":"(0 – 100) °C"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648978","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"ciśnienie","range":"(0 – 0,6) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0 – 0,6) MPa","reference":"PN-EN 303-5:2012 p. 5.2","norm_bases":["PN-EN 303-5:2012 p. 5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe ciśnienie (0 – 0,6) MPa PN-EN 303-5:2012 p. 5.2 Kotly grzewcze na paliwa stale cisnienie (0 – 0,6) MPa PN-EN 303-5:2012 p. 5.2","categories":["petro"],"row_index":413,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(0 – 0,6) MPa"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) pressure PN-EN 303-5:2012 p. 5.2","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 压力 PN-EN 303-5:2012 p. 5.2","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"压力","range":"(0 – 0,6) MPa"}]},{"_id":"6a7d75f9441eff5f15648979","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"strumień masy","range":"(0 – 12000) kg/h"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\nstrumień masy (0 – 12000) kg/h\n(z obliczeń)","reference":"PN-EN 303-5:2012 p. 5.2","norm_bases":["PN-EN 303-5:2012 p. 5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe Zakres:\nstrumień masy (0 – 12000) kg/h\n(z obliczeń) PN-EN 303-5:2012 p. 5.2 Kotly grzewcze na paliwa stale Zakres:\nstrumien masy (0 – 12000) kg/h\n(z obliczen) PN-EN 303-5:2012 p. 5.2","categories":["petro"],"row_index":414,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"mass flow rate","range":"(0 – 12000) kg/h"},{"name":"(calculated)"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) mass flow rate (calculated) PN-EN 303-5:2012 p. 5.2","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","parameters_zh":[{"name":"质量流量","range":"(0 – 12000) kg/h"},{"name":"（计算得出）"}],"search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 质量流量 （计算得出） PN-EN 303-5:2012 p. 5.2","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564897a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"strumień objętości :","range":"(0,09 – 12) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień objętości : (0,09 – 12) m3/h","reference":"PN-EN 303-5:2012 p. 5.2","norm_bases":["PN-EN 303-5:2012 p. 5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe strumień objętości : (0,09 – 12) m3/h PN-EN 303-5:2012 p. 5.2 Kotly grzewcze na paliwa stale strumien objetosci : (0,09 – 12) m3/h PN-EN 303-5:2012 p. 5.2","categories":["petro"],"row_index":415,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"volume flow rate :","range":"(0,09 – 12) m3/h"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) volume flow rate : PN-EN 303-5:2012 p. 5.2","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 体积流量： PN-EN 303-5:2012 p. 5.2","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"体积流量：","range":"(0,09 – 12) m3/h"}]},{"_id":"6a7d75f9441eff5f1564897b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"PARAMETRY PALIWA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY PALIWA:","reference":"PN-EN 303-5:2012 p. 5.2","norm_bases":["PN-EN 303-5:2012 p. 5.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe PARAMETRY PALIWA: PN-EN 303-5:2012 p. 5.2 Kotly grzewcze na paliwa stale PARAMETRY PALIWA: PN-EN 303-5:2012 p. 5.2","categories":["petro"],"row_index":416,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FUEL PARAMETERS:","search_en":"Heating boilers for solid fuels FUEL PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 303-5:2012 p. 5.2","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃料参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p. 5.2","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"燃料参数："},{"_id":"6a7d75f9441eff5f1564897c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"strumień masy","range":"(0 – 50) kg/h"}],"technique":null,"techniques":[],"computed":[],"activity":"strumień masy (0 – 50) kg/h","reference":"PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4","norm_bases":["PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe strumień masy (0 – 50) kg/h PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4 Kotly grzewcze na paliwa stale strumien masy (0 – 50) kg/h PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4","categories":["petro"],"row_index":417,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"mass flow rate","range":"(0 – 50) kg/h"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) mass flow rate PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 质量流量 PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"质量流量","range":"(0 – 50) kg/h"}]},{"_id":"6a7d75f9441eff5f1564897d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"PARAMETRY SPALIN:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY SPALIN:","reference":"PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4","norm_bases":["PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe PARAMETRY SPALIN: PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4 Kotly grzewcze na paliwa stale PARAMETRY SPALIN: PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4","categories":["petro"],"row_index":418,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"FLUE GAS PARAMETERS:","search_en":"Heating boilers for solid fuels FLUE GAS PARAMETERS: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 烟气参数： 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p. 5.2; 5.7.3; 5.7.4","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"烟气参数："},{"_id":"6a7d75f9441eff5f1564897e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"temperatura","range":"(0 – 600) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (0 – 600) °C","reference":"PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6","norm_bases":["PN-EN 303-5:2012 p. 5.7.3","PN-EN 304:2017-11 rys.4,5,6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe temperatura (0 – 600) °C PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6 Kotly grzewcze na paliwa stale temperatura (0 – 600) °C PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6","categories":["petro"],"row_index":419,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(0 – 600) °C"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6","parameters_zh":[{"name":"温度","range":"(0 – 600) °C"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564897f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"ciśnienie","range":"(0 – 250) Pa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (0 – 250) Pa","reference":"PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6","norm_bases":["PN-EN 303-5:2012 p. 5.7.3","PN-EN 304:2017-11 rys.4,5,6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe ciśnienie (0 – 250) Pa PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6 Kotly grzewcze na paliwa stale cisnienie (0 – 250) Pa PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6","categories":["petro"],"row_index":420,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(0 – 250) Pa"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) pressure PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 压力 PN-EN 303-5:2012 p. 5.7.3 | PN-EN 304:2017-11 rys.4,5,6","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"压力","range":"(0 – 250) Pa"}]},{"_id":"6a7d75f9441eff5f15648980","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"Stężenia dwutlenku węgla, tlenku węgla, tlenu","parameters":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,800) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"Emisja CO (z obliczeń)"}],"technique":"Metoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda: PMD- paramagnetyczna","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,800) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna","reference":"PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","norm_bases":["PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe Stężenia dwutlenku węgla, tlenku węgla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,800) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczeń)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 Kotly grzewcze na paliwa stale Stezenia dwutlenku wegla, tlenku wegla, tlenu\nZakres:\nCO2; (0,1 – 20) %\nCO; (0,001 – 0,800) %\nO2; (0,1 – 21) %\nO2; (0 – 21) %\nEmisja CO (z obliczen)\nMetoda NDIR; Metoda: PMD- paramagnetyczna; Metoda elektrochemiczna PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","categories":["environment","petro"],"row_index":421,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of carbon dioxide, carbon monoxide, oxygen","parameters_en":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,800) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO emission (calculated)"}],"search_en":"Heating boilers for solid fuels Concentrations of carbon dioxide, carbon monoxide, oxygen NDIR method; Method: PMD- paramagnetic; Electrochemical method Gas and Heating Appliances Testing Laboratory (GU-1) CO2; CO; O2; O2; CO emission (calculated) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","technique_en":"NDIR method; Method: PMD- paramagnetic; Electrochemical method","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 二氧化碳、一氧化碳、氧浓度 NDIR 法；PMD 顺磁法；电化学法 燃气与供暖器具检测实验室（GU-1） CO 排放量（计算值） PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"CO2;","range":"(0,1 – 20) %"},{"name":"CO;","range":"(0,001 – 0,800) %"},{"name":"O2;","range":"(0,1 – 21) %"},{"name":"O2;","range":"(0 – 21) %"},{"name":"CO 排放量（计算值）"}],"methodology_zh":"二氧化碳、一氧化碳、氧浓度","technique_zh":"NDIR 法；PMD 顺磁法；电化学法"},{"_id":"6a7d75f9441eff5f15648981","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"Stężenia tlenku azotu, dwutlenku azotu, tlenków azotu (NO, NO2, NOx), OGC.","parameters":[{"name":"NO","range":"(0,1 – 1993) ppm"},{"name":"NO2","range":"(0,1 – 232) ppm"},{"name":"NOx","range":"(0,1 – 1993) ppm"},{"name":"NO","range":"(0,5 – 190) ppm"},{"name":"NOx","range":"(0,5 – 190) ppm"},{"name":"OGC;","range":"(0,269 – 1286) mg/m3"},{"name":"Emisja CO2; NO, NO2, NOx, OGC (z obliczeń)"}],"technique":"Metoda NDIR; Metoda chemiluminescencja; Metoda FID","techniques":["Metoda NDIR","Metoda chemiluminescencja","Metoda FID"],"computed":[],"activity":"Stężenia tlenku azotu, dwutlenku azotu, tlenków azotu (NO, NO2, NOx), OGC.\nZakres:\nNO (0,1 – 1993) ppm\nNO2 (0,1 – 232) ppm\nNOx (0,1 – 1993) ppm\nNO (0,5 – 190) ppm\nNOx (0,5 – 190) ppm\nOGC; (0,269 – 1286) mg/m3\nEmisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda NDIR; Metoda chemiluminescencja; Metoda FID","reference":"PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","norm_bases":["PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe Stężenia tlenku azotu, dwutlenku azotu, tlenków azotu (NO, NO2, NOx), OGC.\nZakres:\nNO (0,1 – 1993) ppm\nNO2 (0,1 – 232) ppm\nNOx (0,1 – 1993) ppm\nNO (0,5 – 190) ppm\nNOx (0,5 – 190) ppm\nOGC; (0,269 – 1286) mg/m3\nEmisja CO2; NO, NO2, NOx, OGC (z obliczeń)\nMetoda NDIR; Metoda chemiluminescencja; Metoda FID PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 Kotly grzewcze na paliwa stale Stezenia tlenku azotu, dwutlenku azotu, tlenkow azotu (NO, NO2, NOx), OGC.\nZakres:\nNO (0,1 – 1993) ppm\nNO2 (0,1 – 232) ppm\nNOx (0,1 – 1993) ppm\nNO (0,5 – 190) ppm\nNOx (0,5 – 190) ppm\nOGC; (0,269 – 1286) mg/m3\nEmisja CO2; NO, NO2, NOx, OGC (z obliczen)\nMetoda NDIR; Metoda chemiluminescencja; Metoda FID PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","categories":["environment","petro"],"row_index":422,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Concentrations of nitrogen monoxide, nitrogen dioxide, nitrogen oxides (NO, NO2, NOx), OGC.","parameters_en":[{"name":"NO","range":"(0,1 – 1993) ppm"},{"name":"NO2","range":"(0,1 – 232) ppm"},{"name":"NOx","range":"(0,1 – 1993) ppm"},{"name":"NO","range":"(0,5 – 190) ppm"},{"name":"NOx","range":"(0,5 – 190) ppm"},{"name":"OGC;","range":"(0,269 – 1286) mg/m3"},{"name":"CO2; NO, NO2, NOx, OGC emission (calculated)"}],"search_en":"Heating boilers for solid fuels Concentrations of nitrogen monoxide, nitrogen dioxide, nitrogen oxides (NO, NO2, NOx), OGC. NDIR method; Chemiluminescence method; FID method Gas and Heating Appliances Testing Laboratory (GU-1) NO NO2 NOx NO NOx OGC; CO2; NO, NO2, NOx, OGC emission (calculated) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","technique_en":"NDIR method; Chemiluminescence method; FID method","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） NO NO2 NOx NO NOx CO2、NO、NO2、NOx、OGC 排放（由计算得出） PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","parameters_zh":[{"name":"NO","range":"(0,1 – 1993) ppm"},{"name":"NO2","range":"(0,1 – 232) ppm"},{"name":"NOx","range":"(0,1 – 1993) ppm"},{"name":"NO","range":"(0,5 – 190) ppm"},{"name":"NOx","range":"(0,5 – 190) ppm"},{"name":"OGC;","range":"(0,269 – 1286) mg/m3"},{"name":"CO2、NO、NO2、NOx、OGC 排放（由计算得出）"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648982","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"PARAMETRY POWIETRZA ATMOSFERYCZNEGO W MIEJSCU BADAŃ:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY POWIETRZA ATMOSFERYCZNEGO W MIEJSCU BADAŃ:","reference":"PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","norm_bases":["PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe PARAMETRY POWIETRZA ATMOSFERYCZNEGO W MIEJSCU BADAŃ: PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 Kotly grzewcze na paliwa stale PARAMETRY POWIETRZA ATMOSFERYCZNEGO W MIEJSCU BADAN: PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","categories":["petro"],"row_index":423,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"AMBIENT AIR PARAMETERS AT THE TEST SITE:","search_en":"Heating boilers for solid fuels AMBIENT AIR PARAMETERS AT THE TEST SITE: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648983","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"temperatura","range":"(10 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura (10 – 35) °C","reference":"PN-EN 303-5:2012 p. 5.7.1; 5.7.3","norm_bases":["PN-EN 303-5:2012 p. 5.7.1; 5.7.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe temperatura (10 – 35) °C PN-EN 303-5:2012 p. 5.7.1; 5.7.3 Kotly grzewcze na paliwa stale temperatura (10 – 35) °C PN-EN 303-5:2012 p. 5.7.1; 5.7.3","categories":["petro"],"row_index":424,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature","range":"(10 – 35) °C"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) temperature PN-EN 303-5:2012 p. 5.7.1; 5.7.3","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 温度 PN-EN 303-5:2012 p. 5.7.1; 5.7.3","parameters_zh":[{"name":"温度","range":"(10 – 35) °C"}],"test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648984","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"ciśnienie","range":"(940 – 1060) hPa"}],"technique":null,"techniques":[],"computed":[],"activity":"ciśnienie (940 – 1060) hPa","reference":"PN-EN 297:2002 p. 4.1.6.7","norm_bases":["PN-EN 297:2002 p. 4.1.6.7"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe ciśnienie (940 – 1060) hPa PN-EN 297:2002 p. 4.1.6.7 Kotly grzewcze na paliwa stale cisnienie (940 – 1060) hPa PN-EN 297:2002 p. 4.1.6.7","categories":["petro"],"row_index":425,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"pressure","range":"(940 – 1060) hPa"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) pressure PN-EN 297:2002 p. 4.1.6.7","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 压力 PN-EN 297:2002 p. 4.1.6.7","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"压力","range":"(940 – 1060) hPa"}]},{"_id":"6a7d75f9441eff5f15648985","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"BILANS CIEPLNY (z obliczeń):","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"BILANS CIEPLNY (z obliczeń):","reference":"PN-EN 297:2002 p. 4.1.6.7","norm_bases":["PN-EN 297:2002 p. 4.1.6.7"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe BILANS CIEPLNY (z obliczeń): PN-EN 297:2002 p. 4.1.6.7 Kotly grzewcze na paliwa stale BILANS CIEPLNY (z obliczen): PN-EN 297:2002 p. 4.1.6.7","categories":["petro"],"row_index":426,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"HEAT BALANCE (calculated):","search_en":"Heating boilers for solid fuels HEAT BALANCE (calculated): Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 297:2002 p. 4.1.6.7","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 热平衡（计算值）： 燃气与供暖器具检测实验室（GU-1） PN-EN 297:2002 p. 4.1.6.7","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"热平衡（计算值）："},{"_id":"6a7d75f9441eff5f15648986","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"moc cieplna","range":"(3 – 400) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna (3 – 400) kW","reference":"PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1","norm_bases":["PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe moc cieplna (3 – 400) kW PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1 Kotly grzewcze na paliwa stale moc cieplna (3 – 400) kW PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1","categories":["petro"],"row_index":427,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat output","range":"(3 – 400) kW"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) heat output PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648987","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"moc cieplna doprowadzona z paliwem","range":"(3 – 400) kW"}],"technique":null,"techniques":[],"computed":[],"activity":"moc cieplna doprowadzona z paliwem (3 – 400) kW","reference":"PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2","norm_bases":["PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe moc cieplna doprowadzona z paliwem (3 – 400) kW PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2 Kotly grzewcze na paliwa stale moc cieplna doprowadzona z paliwem (3 – 400) kW PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2","categories":["petro"],"row_index":428,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"heat input from fuel","range":"(3 – 400) kW"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) heat input from fuel PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 燃料输入热功率 PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"燃料输入热功率","range":"(3 – 400) kW"}]},{"_id":"6a7d75f9441eff5f15648988","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"sprawność cieplna","range":"(20 – 95) %"}],"technique":null,"techniques":[],"computed":[],"activity":"sprawność cieplna (20 – 95) %","reference":"PN-EN 303-5:2012 p.5.10.3","norm_bases":["PN-EN 303-5:2012 p.5.10.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe sprawność cieplna (20 – 95) % PN-EN 303-5:2012 p.5.10.3 Kotly grzewcze na paliwa stale sprawnosc cieplna (20 – 95) % PN-EN 303-5:2012 p.5.10.3","categories":["petro"],"row_index":429,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"thermal efficiency","range":"(20 – 95) %"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) thermal efficiency PN-EN 303-5:2012 p.5.10.3","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 热效率 PN-EN 303-5:2012 p.5.10.3","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"热效率","range":"(20 – 95) %"}]},{"_id":"6a7d75f9441eff5f15648989","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"strata kominowa","range":"(5 – 40) %"}],"technique":null,"techniques":[],"computed":[],"activity":"strata kominowa (5 – 40) %","reference":"PN-EN 303-5:2012 p. 5.10.3.2","norm_bases":["PN-EN 303-5:2012 p. 5.10.3.2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe strata kominowa (5 – 40) % PN-EN 303-5:2012 p. 5.10.3.2 Kotly grzewcze na paliwa stale strata kominowa (5 – 40) % PN-EN 303-5:2012 p. 5.10.3.2","categories":["petro"],"row_index":430,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"stack loss","range":"(5 – 40) %"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) stack loss PN-EN 303-5:2012 p. 5.10.3.2","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 排烟热损失 PN-EN 303-5:2012 p. 5.10.3.2","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"排烟热损失","range":"(5 – 40) %"}]},{"_id":"6a7d75f9441eff5f1564898a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"straty niezupełnego spalania"}],"technique":null,"techniques":[],"computed":[],"activity":"straty niezupełnego spalania","reference":"PN-EN 303-5:2012 p.5.10.3","norm_bases":["PN-EN 303-5:2012 p.5.10.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe straty niezupełnego spalania PN-EN 303-5:2012 p.5.10.3 Kotly grzewcze na paliwa stale straty niezupelnego spalania PN-EN 303-5:2012 p.5.10.3","categories":["petro"],"row_index":431,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"losses due to incomplete combustion"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) losses due to incomplete combustion PN-EN 303-5:2012 p.5.10.3","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 不完全燃烧损失 PN-EN 303-5:2012 p.5.10.3","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"不完全燃烧损失"}]},{"_id":"6a7d75f9441eff5f1564898b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"strata niecałkowitego spalania (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"strata niecałkowitego spalania (z obliczeń)","reference":"PN-EN 303-5:2012 p.5.10.3","norm_bases":["PN-EN 303-5:2012 p.5.10.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe strata niecałkowitego spalania (z obliczeń) PN-EN 303-5:2012 p.5.10.3 Kotly grzewcze na paliwa stale strata niecalkowitego spalania (z obliczen) PN-EN 303-5:2012 p.5.10.3","categories":["petro"],"row_index":432,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"loss due to incomplete combustion (calculated)"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) loss due to incomplete combustion (calculated) PN-EN 303-5:2012 p.5.10.3","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p.5.10.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564898c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"straty do otoczenia"}],"technique":null,"techniques":[],"computed":[],"activity":"straty do otoczenia","reference":"PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3","norm_bases":["PN-EN 304:2017-11 p. A.8.3","PN-EN 303-5:2012 p.5.10.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe straty do otoczenia PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3 Kotly grzewcze na paliwa stale straty do otoczenia PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3","categories":["petro"],"row_index":433,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"losses to the surroundings"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) losses to the surroundings PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564898d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE KOTŁA:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"PARAMETRY TECHNICZNO - EKSPLOATACYJNE KOTŁA:","reference":"PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3","norm_bases":["PN-EN 304:2017-11 p. A.8.3","PN-EN 303-5:2012 p.5.10.3"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe PARAMETRY TECHNICZNO - EKSPLOATACYJNE KOTŁA: PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3 Kotly grzewcze na paliwa stale PARAMETRY TECHNICZNO - EKSPLOATACYJNE KOTLA: PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3","categories":["petro"],"row_index":434,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"TECHNICAL AND OPERATIONAL PARAMETERS OF THE BOILER:","search_en":"Heating boilers for solid fuels TECHNICAL AND OPERATIONAL PARAMETERS OF THE BOILER: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 304:2017-11 p. A.8.3 | PN-EN 303-5:2012 p.5.10.3","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564898e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"opory przepływu wody Ciśnienie wody","range":"(10 – 2000) Pa"}],"technique":null,"techniques":[],"computed":[],"activity":"opory przepływu wody Ciśnienie wody (10 – 2000) Pa","reference":"PN-EN 303-5:2012 p.5.11 | PN-EN 304:2017-11 p. 6.6","norm_bases":["PN-EN 303-5:2012 p.5.11","PN-EN 304:2017-11 p. 6.6"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe opory przepływu wody Ciśnienie wody (10 – 2000) Pa PN-EN 303-5:2012 p.5.11 | PN-EN 304:2017-11 p. 6.6 Kotly grzewcze na paliwa stale opory przeplywu wody Cisnienie wody (10 – 2000) Pa PN-EN 303-5:2012 p.5.11 | PN-EN 304:2017-11 p. 6.6","categories":["water","petro"],"row_index":435,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"water flow resistance Water pressure","range":"(10 – 2000) Pa"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) water flow resistance Water pressure PN-EN 303-5:2012 p.5.11 | PN-EN 304:2017-11 p. 6.6","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p.5.11 | PN-EN 304:2017-11 p. 6.6","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f1564898f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"temperatury powierzchni zewnętrznych","range":"(0 – 200) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatury powierzchni zewnętrznych (0 – 200) °C","reference":"PN-EN 303-5:2012 p. 5.12","norm_bases":["PN-EN 303-5:2012 p. 5.12"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe temperatury powierzchni zewnętrznych (0 – 200) °C PN-EN 303-5:2012 p. 5.12 Kotly grzewcze na paliwa stale temperatury powierzchni zewnetrznych (0 – 200) °C PN-EN 303-5:2012 p. 5.12","categories":["petro"],"row_index":436,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperatures of external surfaces","range":"(0 – 200) °C"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) temperatures of external surfaces PN-EN 303-5:2012 p. 5.12","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p. 5.12","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648990","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"temperatury uchwytów","range":"(0 – 300) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatury uchwytów (0 – 300) °C","reference":"PN-EN 303-5:2012 p. 5.12","norm_bases":["PN-EN 303-5:2012 p. 5.12"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe temperatury uchwytów (0 – 300) °C PN-EN 303-5:2012 p. 5.12 Kotly grzewcze na paliwa stale temperatury uchwytow (0 – 300) °C PN-EN 303-5:2012 p. 5.12","categories":["petro"],"row_index":437,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperatures of handles","range":"(0 – 300) °C"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) temperatures of handles PN-EN 303-5:2012 p. 5.12","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p. 5.12","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648991","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"temperatura podłoża pod kotłem","range":"(0 – 200)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"temperatura podłoża pod kotłem (0 – 200)°C","reference":"PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15","norm_bases":["PN-EN 303-5:2012 p. 5.12","PN-EN 304:2017-11 p. 6.15"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe temperatura podłoża pod kotłem (0 – 200)°C PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15 Kotly grzewcze na paliwa stale temperatura podloza pod kotlem (0 – 200)°C PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15","categories":["petro"],"row_index":438,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"temperature of the floor under the boiler","range":"(0 – 200)°C"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) temperature of the floor under the boiler PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648992","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"DZIAŁANIE AUTOMATYCZNEJ REGULACJI I ZABEZPIECZEŃ:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"DZIAŁANIE AUTOMATYCZNEJ REGULACJI I ZABEZPIECZEŃ:","reference":"PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15","norm_bases":["PN-EN 303-5:2012 p. 5.12","PN-EN 304:2017-11 p. 6.15"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe DZIAŁANIE AUTOMATYCZNEJ REGULACJI I ZABEZPIECZEŃ: PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15 Kotly grzewcze na paliwa stale DZIALANIE AUTOMATYCZNEJ REGULACJI I ZABEZPIECZEN: PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15","categories":["petro"],"row_index":439,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"OPERATION OF AUTOMATIC CONTROLS AND SAFETY DEVICES:","search_en":"Heating boilers for solid fuels OPERATION OF AUTOMATIC CONTROLS AND SAFETY DEVICES: Gas and Heating Appliances Testing Laboratory (GU-1) PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p. 5.12 | PN-EN 304:2017-11 p. 6.15","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648993","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"działanie regulatora temperatury wody i ogranicznika temperatury bezpieczeństwa","range":"(0 – 110) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"działanie regulatora temperatury wody i ogranicznika temperatury bezpieczeństwa (0 – 110) °C","reference":"PN-EN 303-5:2012 p. 5.13","norm_bases":["PN-EN 303-5:2012 p. 5.13"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe działanie regulatora temperatury wody i ogranicznika temperatury bezpieczeństwa (0 – 110) °C PN-EN 303-5:2012 p. 5.13 Kotly grzewcze na paliwa stale dzialanie regulatora temperatury wody i ogranicznika temperatury bezpieczenstwa (0 – 110) °C PN-EN 303-5:2012 p. 5.13","categories":["water","petro"],"row_index":440,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"operation of the water temperature controller and the safety temperature limiter","range":"(0 – 110) °C"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) operation of the water temperature controller and the safety temperature limiter PN-EN 303-5:2012 p. 5.13","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） PN-EN 303-5:2012 p. 5.13","test_object_zh":"固体燃料供暖锅炉"},{"_id":"6a7d75f9441eff5f15648994","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"","parameters":[{"name":"działanie urządzenia do odprowadzania nadwyżki ciepła temperatura wody","range":"(0 – 120) °C"},{"name":"ciśnienie wody","range":"(0,1 – 0,3) MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres:\ndziałanie urządzenia do odprowadzania nadwyżki ciepła temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa","reference":"PN-EN 303-5:2012 p. 5.15","norm_bases":["PN-EN 303-5:2012 p. 5.15"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe Zakres:\ndziałanie urządzenia do odprowadzania nadwyżki ciepła temperatura wody (0 – 120) °C\nciśnienie wody (0,1 – 0,3) MPa PN-EN 303-5:2012 p. 5.15 Kotly grzewcze na paliwa stale Zakres:\ndzialanie urzadzenia do odprowadzania nadwyzki ciepla temperatura wody (0 – 120) °C\ncisnienie wody (0,1 – 0,3) MPa PN-EN 303-5:2012 p. 5.15","categories":["water","petro"],"row_index":441,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","parameters_en":[{"name":"operation of the excess heat discharge device water temperature","range":"(0 – 120) °C"},{"name":"water pressure","range":"(0,1 – 0,3) MPa"}],"search_en":"Heating boilers for solid fuels Gas and Heating Appliances Testing Laboratory (GU-1) operation of the excess heat discharge device water temperature water pressure PN-EN 303-5:2012 p. 5.15","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","search_zh":"固体燃料供暖锅炉 燃气与供暖器具检测实验室（GU-1） 水压 PN-EN 303-5:2012 p. 5.15","test_object_zh":"固体燃料供暖锅炉","parameters_zh":[{"name":"działanie urządzenia do odprowadzania nadwyżki ciepła temperatura wody","range":"(0 – 120) °C"},{"name":"水压","range":"(0,1 – 0,3) MPa"}]},{"_id":"6a7d75f9441eff5f15648995","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kotły grzewcze na paliwa stałe","methodology":"Stężenie pyłów w spalinach","parameters":[{"name":"Zakres","range":"(0,01 – 1) g/m3"}],"technique":"Metoda: grawimetryczna","techniques":["Metoda: grawimetryczna"],"computed":[],"activity":"Stężenie pyłów w spalinach\nZakres (0,01 – 1) g/m3\nMetoda: grawimetryczna","reference":"PN-EN 303-5:2012 p. 5.2; p.5.7.3; p.5.9, Załącznik A","norm_bases":["PN-EN 303-5:2012 p. 5.2; p.5.7.3; p.5.9, Załącznik A"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotły grzewcze na paliwa stałe Stężenie pyłów w spalinach\nZakres (0,01 – 1) g/m3\nMetoda: grawimetryczna PN-EN 303-5:2012 p. 5.2; p.5.7.3; p.5.9, Załącznik A Kotly grzewcze na paliwa stale Stezenie pylow w spalinach\nZakres (0,01 – 1) g/m3\nMetoda: grawimetryczna PN-EN 303-5:2012 p. 5.2; p.5.7.3; p.5.9, Zalacznik A","categories":["petro"],"row_index":442,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Dust concentration in flue gases","parameters_en":[{"name":"Range","range":"(0,01 – 1) g/m3"}],"search_en":"Heating boilers for solid fuels Dust concentration in flue gases Method: gravimetric Gas and Heating Appliances Testing Laboratory (GU-1) Range PN-EN 303-5:2012 p. 5.2; p.5.7.3; p.5.9, Załącznik A","technique_en":"Method: gravimetric","test_object_en":"Heating boilers for solid fuels","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","parameters_zh":[{"name":"范围","range":"(0,01 – 1) g/m3"}],"search_zh":"固体燃料供暖锅炉 烟气中粉尘浓度 方法：重量法 燃气与供暖器具检测实验室（GU-1） 范围 PN-EN 303-5:2012 p. 5.2; p.5.7.3; p.5.9, Załącznik A","test_object_zh":"固体燃料供暖锅炉","methodology_zh":"烟气中粉尘浓度","technique_zh":"方法：重量法"},{"_id":"6a7d75f9441eff5f15648996","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Urządzenia spalające paliwa gazowe używane do gotowania, ogrzewania, wytwarzania gorącej wody, chłodzenia, oświetlania , prania lub zmywania i w odpowiednich przypadkach mających temperaturę wody nie przekraczającą 105°C palniki z wymuszonym ciągiem oraz urządzenia grzewcze przeznaczone do wyposażenia w takie palniki, (bez urządzeń przemysłowych) E, Urządzenia zabezpieczające, urządzenia kontroli lub urządzenia regulacyjne i podzespoły oddzielnie zbywane i zaprojektowane w celu przyłączenia do urządzenia spalającego paliwo gazowe lub po zmontowaniu tworzące takie urządzenie, (bez urządzeń przemysłowych) E","methodology":"Cechy i właściwości do oceny bezpieczeństwa działania:","parameters":[{"name":"funkcjonalność armatury"},{"name":"sprawdzenie materiałów"},{"name":"stabilność mechaniczna"},{"name":"kondensacja"},{"name":"zagrożenie wybuchowe"},{"name":"penetracja wody"},{"name":"normalne i anormalne wahania energii zasilającej"},{"name":"ryzyko porażenia elektrycznego"},{"name":"wytrzymałość na ciśnienie"},{"name":"niezawodność urządzeń zabezpieczających, kontroli i regulacji"},{"name":"wzajemne oddziaływanie urządzeń sterujących i zabezpieczających"},{"name":"zabezpieczenia elementów ustawionych przez producenta"},{"name":"urządzenia kontrolne i nastawcze"},{"name":"wypływ niespalonego gazu"},{"name":"nieszczelności"},{"name":"akumulacja gazu w urządzeniu i w pomieszczeniu"},{"name":"bezpieczeństwo zapłonu"},{"name":"jakość i stabilność spalania"},{"name":"szczelność układu spalinowego"},{"name":"wypływ spalin do pomieszczenia w przypadku zakłóceń ciągu"},{"name":"temperatury nagrzania elementów Higieniczność elementów stykających się z wodą pitną i żywnością Racjonalne zużycie energii"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny bezpieczeństwa działania:\nZakres:\nfunkcjonalność armatury\nsprawdzenie materiałów\nstabilność mechaniczna\nkondensacja\nzagrożenie wybuchowe\npenetracja wody\nnormalne i anormalne wahania energii zasilającej\nryzyko porażenia elektrycznego\nwytrzymałość na ciśnienie\nniezawodność urządzeń zabezpieczających, kontroli i regulacji\nwzajemne oddziaływanie urządzeń sterujących i zabezpieczających\nzabezpieczenia elementów ustawionych przez producenta\nurządzenia kontrolne i nastawcze\nwypływ niespalonego gazu\nnieszczelności\nakumulacja gazu w urządzeniu i w pomieszczeniu\nbezpieczeństwo zapłonu\njakość i stabilność spalania\nszczelność układu spalinowego\nwypływ spalin do pomieszczenia w przypadku zakłóceń ciągu\ntemperatury nagrzania elementów Higieniczność elementów stykających się z wodą pitną i żywnością Racjonalne zużycie energii","reference":"PN-EN 12309-1 | PN-EN 12309-2 | PN-EN 13278 | PN-EN 14543 | PN-EN 1596 | PN-EN 203-1 | PN-EN 203-2-1 | PN-EN 203-2-2 | PN-EN 203-2-3 | PN-EN 203-2-4 | PN-EN 203-2-6 | PN-EN 203-2-7 | PN-EN 203-2-8 | PN-EN 203-2-9 | PN-EN 203-2-10 | PN-EN 203-2-11 | PN-EN 26 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 30-1-1 | PN-EN 30-1-2 | PN-EN 30-2-1 | PN-EN 30-2-2 | PN-EN 30-1-3 | PN-EN 30-1-4","norm_bases":["PN-EN 12309-1","PN-EN 12309-2","PN-EN 13278","PN-EN 14543","PN-EN 1596","PN-EN 203-1","PN-EN 203-2-1","PN-EN 203-2-2","PN-EN 203-2-3","PN-EN 203-2-4","PN-EN 203-2-6","PN-EN 203-2-7","PN-EN 203-2-8","PN-EN 203-2-9","PN-EN 203-2-10","PN-EN 203-2-11","PN-EN 26 z wyłączeniem punktów : 8.7 i 8.8","PN-EN 30-1-1","PN-EN 30-1-2","PN-EN 30-2-1","PN-EN 30-2-2","PN-EN 30-1-3","PN-EN 30-1-4"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Urządzenia spalające paliwa gazowe używane do gotowania, ogrzewania, wytwarzania gorącej wody, chłodzenia, oświetlania , prania lub zmywania i w odpowiednich przypadkach mających temperaturę wody nie przekraczającą 105°C palniki z wymuszonym ciągiem oraz urządzenia grzewcze przeznaczone do wyposażenia w takie palniki, (bez urządzeń przemysłowych) E, Urządzenia zabezpieczające, urządzenia kontroli lub urządzenia regulacyjne i podzespoły oddzielnie zbywane i zaprojektowane w celu przyłączenia do urządzenia spalającego paliwo gazowe lub po zmontowaniu tworzące takie urządzenie, (bez urządzeń przemysłowych) E Cechy i właściwości do oceny bezpieczeństwa działania:\nZakres:\nfunkcjonalność armatury\nsprawdzenie materiałów\nstabilność mechaniczna\nkondensacja\nzagrożenie wybuchowe\npenetracja wody\nnormalne i anormalne wahania energii zasilającej\nryzyko porażenia elektrycznego\nwytrzymałość na ciśnienie\nniezawodność urządzeń zabezpieczających, kontroli i regulacji\nwzajemne oddziaływanie urządzeń sterujących i zabezpieczających\nzabezpieczenia elementów ustawionych przez producenta\nurządzenia kontrolne i nastawcze\nwypływ niespalonego gazu\nnieszczelności\nakumulacja gazu w urządzeniu i w pomieszczeniu\nbezpieczeństwo zapłonu\njakość i stabilność spalania\nszczelność układu spalinowego\nwypływ spalin do pomieszczenia w przypadku zakłóceń ciągu\ntemperatury nagrzania elementów Higieniczność elementów stykających się z wodą pitną i żywnością Racjonalne zużycie energii PN-EN 12309-1 | PN-EN 12309-2 | PN-EN 13278 | PN-EN 14543 | PN-EN 1596 | PN-EN 203-1 | PN-EN 203-2-1 | PN-EN 203-2-2 | PN-EN 203-2-3 | PN-EN 203-2-4 | PN-EN 203-2-6 | PN-EN 203-2-7 | PN-EN 203-2-8 | PN-EN 203-2-9 | PN-EN 203-2-10 | PN-EN 203-2-11 | PN-EN 26 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 30-1-1 | PN-EN 30-1-2 | PN-EN 30-2-1 | PN-EN 30-2-2 | PN-EN 30-1-3 | PN-EN 30-1-4 Urzadzenia spalajace paliwa gazowe uzywane do gotowania, ogrzewania, wytwarzania goracej wody, chlodzenia, oswietlania , prania lub zmywania i w odpowiednich przypadkach majacych temperature wody nie przekraczajaca 105°C palniki z wymuszonym ciagiem oraz urzadzenia grzewcze przeznaczone do wyposazenia w takie palniki, (bez urzadzen przemyslowych) E, Urzadzenia zabezpieczajace, urzadzenia kontroli lub urzadzenia regulacyjne i podzespoly oddzielnie zbywane i zaprojektowane w celu przylaczenia do urzadzenia spalajacego paliwo gazowe lub po zmontowaniu tworzace takie urzadzenie, (bez urzadzen przemyslowych) E Cechy i wlasciwosci do oceny bezpieczenstwa dzialania:\nZakres:\nfunkcjonalnosc armatury\nsprawdzenie materialow\nstabilnosc mechaniczna\nkondensacja\nzagrozenie wybuchowe\npenetracja wody\nnormalne i anormalne wahania energii zasilajacej\nryzyko porazenia elektrycznego\nwytrzymalosc na cisnienie\nniezawodnosc urzadzen zabezpieczajacych, kontroli i regulacji\nwzajemne oddzialywanie urzadzen sterujacych i zabezpieczajacych\nzabezpieczenia elementow ustawionych przez producenta\nurzadzenia kontrolne i nastawcze\nwyplyw niespalonego gazu\nnieszczelnosci\nakumulacja gazu w urzadzeniu i w pomieszczeniu\nbezpieczenstwo zaplonu\njakosc i stabilnosc spalania\nszczelnosc ukladu spalinowego\nwyplyw spalin do pomieszczenia w przypadku zaklocen ciagu\ntemperatury nagrzania elementow Higienicznosc elementow stykajacych sie z woda pitna i zywnoscia Racjonalne zuzycie energii PN-EN 12309-1 | PN-EN 12309-2 | PN-EN 13278 | PN-EN 14543 | PN-EN 1596 | PN-EN 203-1 | PN-EN 203-2-1 | PN-EN 203-2-2 | PN-EN 203-2-3 | PN-EN 203-2-4 | PN-EN 203-2-6 | PN-EN 203-2-7 | PN-EN 203-2-8 | PN-EN 203-2-9 | PN-EN 203-2-10 | PN-EN 203-2-11 | PN-EN 26 z wylaczeniem punktow : 8.7 i 8.8 | PN-EN 30-1-1 | PN-EN 30-1-2 | PN-EN 30-2-1 | PN-EN 30-2-2 | PN-EN 30-1-3 | PN-EN 30-1-4","categories":["materials","petro","water","food"],"row_index":443,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Characteristics and properties for the assessment of operational safety:","parameters_en":[{"name":"functionality of fittings"},{"name":"verification of materials"},{"name":"mechanical stability"},{"name":"condensation"},{"name":"explosion hazard"},{"name":"water penetration"},{"name":"normal and abnormal supply power fluctuations"},{"name":"risk of electric shock"},{"name":"pressure resistance"},{"name":"reliability of safety, control and regulating devices"},{"name":"interaction of control and safety devices"},{"name":"protection of components set by the manufacturer"},{"name":"control and setting devices"},{"name":"release of unburned gas"},{"name":"leaks"},{"name":"gas accumulation in the appliance and in the room"},{"name":"ignition safety"},{"name":"combustion quality and stability"},{"name":"tightness of the flue gas system"},{"name":"spillage of flue gases into the room in the event of draught disturbance"},{"name":"heating temperatures of components Hygiene of components in contact with drinking water and food Rational energy consumption"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Appliances burning gaseous fuels used for cooking, heating, hot water production, refrigeration, lighting, washing or dishwashing and, where applicable, having a water temperature not exceeding 105°C forced draught burners and heating bodies to be equipped with such burners, (excluding industrial appliances) E, Safety devices, controlling devices or regulating devices and sub-assemblies marketed separately and designed to be incorporated into an appliance burning gaseous fuel or assembled to constitute such an appliance, (excluding industrial appliances) E Characteristics and properties for the assessment of operational safety: Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. functionality of fittings verification of materials mechanical stability condensation explosion hazard water penetration normal and abnormal supply power fluctuations risk of electric shock pressure resistance reliability of safety, control and regulating devices interaction of control and safety devices protection of components set by the manufacturer control and setting devices release of unburned gas leaks gas accumulation in the appliance and in the room ignition safety combustion quality and stability tightness of the flue gas system spillage of flue gases into the room in the event of draught disturbance heating temperatures of components Hygiene of components in contact with drinking water and food Rational energy consumption PN-EN 12309-1 | PN-EN 12309-2 | PN-EN 13278 | PN-EN 14543 | PN-EN 1596 | PN-EN 203-1 | PN-EN 203-2-1 | PN-EN 203-2-2 | PN-EN 203-2-3 | PN-EN 203-2-4 | PN-EN 203-2-6 | PN-EN 203-2-7 | PN-EN 203-2-8 | PN-EN 203-2-9 | PN-EN 203-2-10 | PN-EN 203-2-11 | PN-EN 26 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 30-1-1 | PN-EN 30-1-2 | PN-EN 30-2-1 | PN-EN 30-2-2 | PN-EN 30-1-3 | PN-EN 30-1-4","test_object_en":"Appliances burning gaseous fuels used for cooking, heating, hot water production, refrigeration, lighting, washing or dishwashing and, where applicable, having a water temperature not exceeding 105°C forced draught burners and heating bodies to be equipped with such burners, (excluding industrial appliances) E, Safety devices, controlling devices or regulating devices and sub-assemblies marketed separately and designed to be incorporated into an appliance burning gaseous fuel or assembled to constitute such an appliance, (excluding industrial appliances) E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"用于动作安全性评定的特征与性能： 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 阀件的功能性 材料检查 机械稳定性 冷凝 爆炸危险 水的渗入 供电能量的正常与非正常波动 触电风险 耐压强度 安全、控制与调节装置的可靠性 制造商预设元件的防护 控制与整定装置 未燃气体的泄出 泄漏 气体在设备内与房间内的积聚 点火安全性 燃烧质量与稳定性 排烟系统的密封性 抽力受扰时烟气向房间的泄出 元件的加热温度；与饮用水和食品接触元件的卫生性；能源的合理消耗 PN-EN 12309-1 | PN-EN 12309-2 | PN-EN 13278 | PN-EN 14543 | PN-EN 1596 | PN-EN 203-1 | PN-EN 203-2-1 | PN-EN 203-2-2 | PN-EN 203-2-3 | PN-EN 203-2-4 | PN-EN 203-2-6 | PN-EN 203-2-7 | PN-EN 203-2-8 | PN-EN 203-2-9 | PN-EN 203-2-10 | PN-EN 203-2-11 | PN-EN 26 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 30-1-1 | PN-EN 30-1-2 | PN-EN 30-2-1 | PN-EN 30-2-2 | PN-EN 30-1-3 | PN-EN 30-1-4","methodology_zh":"用于动作安全性评定的特征与性能：","parameters_zh":[{"name":"阀件的功能性"},{"name":"材料检查"},{"name":"机械稳定性"},{"name":"冷凝"},{"name":"爆炸危险"},{"name":"水的渗入"},{"name":"供电能量的正常与非正常波动"},{"name":"触电风险"},{"name":"耐压强度"},{"name":"安全、控制与调节装置的可靠性"},{"name":"wzajemne oddziaływanie urządzeń sterujących i zabezpieczających"},{"name":"制造商预设元件的防护"},{"name":"控制与整定装置"},{"name":"未燃气体的泄出"},{"name":"泄漏"},{"name":"气体在设备内与房间内的积聚"},{"name":"点火安全性"},{"name":"燃烧质量与稳定性"},{"name":"排烟系统的密封性"},{"name":"抽力受扰时烟气向房间的泄出"},{"name":"元件的加热温度；与饮用水和食品接触元件的卫生性；能源的合理消耗"}]},{"_id":"6a7d75f9441eff5f15648997","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Urządzenia spalające paliwa gazowe używane do gotowania, ogrzewania, wytwarzania gorącej wody, chłodzenia, oświetlania , prania lub zmywania i w odpowiednich przypadkach mających temperaturę wody nie przekraczającą 105°C palniki z wymuszonym ciągiem oraz urządzenia grzewcze przeznaczone do wyposażenia w takie palniki, (bez urządzeń przemysłowych) E, Urządzenia zabezpieczające, urządzenia kontroli lub urządzenia regulacyjne i podzespoły oddzielnie zbywane i zaprojektowane w celu przyłączenia do urządzenia spalającego paliwo gazowe lub po zmontowaniu tworzące takie urządzenie, (bez urządzeń przemysłowych) E","methodology":"Cechy i właściwości do oceny bezpieczeństwa działania:","parameters":[{"name":"funkcjonalność armatury"},{"name":"sprawdzenie materiałów"},{"name":"stabilność mechaniczna"},{"name":"kondensacja"},{"name":"zagrożenie wybuchowe"},{"name":"penetracja wody"},{"name":"normalne i anormalne wahania energii zasilającej"},{"name":"ryzyko porażenia elektrycznego"},{"name":"wytrzymałość na ciśnienie"},{"name":"niezawodność urządzeń zabezpieczających, kontroli i regulacji"},{"name":"wzajemne odziaływanie urządzeń sterujących i zabezpieczających"},{"name":"zabezpieczenia elementów ustawionych przez producenta"},{"name":"urządzenia kontrolne i nastawcze"},{"name":"wypływ niespalonego gazu"},{"name":"nieszczelności"},{"name":"akumulacja gazu w urządzeniu i w pomieszczeniu"},{"name":"bezpieczeństwo zapłonu"},{"name":"jakość i stabilność spalania"},{"name":"szczelność układu spalinowego"},{"name":"wypływ spalin do pomieszczenia w przypadku zakłóceń ciągu"},{"name":"temperatury nagrzania elementów Higieniczność elementów stykających się z wodą pitną i żywnością Racjonalne zużycie energii"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny bezpieczeństwa działania:\nZakres:\nfunkcjonalność armatury\nsprawdzenie materiałów\nstabilność mechaniczna\nkondensacja\nzagrożenie wybuchowe\npenetracja wody\nnormalne i anormalne wahania energii zasilającej\nryzyko porażenia elektrycznego\nwytrzymałość na ciśnienie\nniezawodność urządzeń zabezpieczających, kontroli i regulacji\nwzajemne odziaływanie urządzeń sterujących i zabezpieczających\nzabezpieczenia elementów ustawionych przez producenta\nurządzenia kontrolne i nastawcze\nwypływ niespalonego gazu\nnieszczelności\nakumulacja gazu w urządzeniu i w pomieszczeniu\nbezpieczeństwo zapłonu\njakość i stabilność spalania\nszczelność układu spalinowego\nwypływ spalin do pomieszczenia w przypadku zakłóceń ciągu\ntemperatury nagrzania elementów Higieniczność elementów stykających się z wodą pitną i żywnością Racjonalne zużycie energii","reference":"PN-EN 303-3 | PN-EN 416 z wyłączeniem punktów 7.1 ; 7.2 ; 7.3 ; 7.4 ; 7.5 | PN-EN 419 z wyłączeniem punktu 7 | PN-EN 449 | PN-EN 461 | PN-EN 15502-1 | PN-EN 15502-2-1 z wyłączeniem punktów 8.102 ; 8.103 | PN-EN 15502-2-2 | PN-EN 484 | PN-EN 497 | PN-EN 498 | PN-EN 509 | PN-EN 521 | PN-EN 613 | PN-EN 624 | PN-EN 732 | PN-EN 751-1 | PN-EN 751-2 | PN-EN 751-3 | PN-EN 89 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 437 | PN-EN 14829 | PN-EN 17082 | PN-EN 17175","norm_bases":["PN-EN 303-3","PN-EN 416 z wyłączeniem punktów 7.1 ; 7.2 ; 7.3 ; 7.4 ; 7.5","PN-EN 419 z wyłączeniem punktu 7","PN-EN 449","PN-EN 461","PN-EN 15502-1","PN-EN 15502-2-1 z wyłączeniem punktów 8.102 ; 8.103","PN-EN 15502-2-2","PN-EN 484","PN-EN 497","PN-EN 498","PN-EN 509","PN-EN 521","PN-EN 613","PN-EN 624","PN-EN 732","PN-EN 751-1","PN-EN 751-2","PN-EN 751-3","PN-EN 89 z wyłączeniem punktów : 8.7 i 8.8","PN-EN 437","PN-EN 14829","PN-EN 17082","PN-EN 17175"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Urządzenia spalające paliwa gazowe używane do gotowania, ogrzewania, wytwarzania gorącej wody, chłodzenia, oświetlania , prania lub zmywania i w odpowiednich przypadkach mających temperaturę wody nie przekraczającą 105°C palniki z wymuszonym ciągiem oraz urządzenia grzewcze przeznaczone do wyposażenia w takie palniki, (bez urządzeń przemysłowych) E, Urządzenia zabezpieczające, urządzenia kontroli lub urządzenia regulacyjne i podzespoły oddzielnie zbywane i zaprojektowane w celu przyłączenia do urządzenia spalającego paliwo gazowe lub po zmontowaniu tworzące takie urządzenie, (bez urządzeń przemysłowych) E Cechy i właściwości do oceny bezpieczeństwa działania:\nZakres:\nfunkcjonalność armatury\nsprawdzenie materiałów\nstabilność mechaniczna\nkondensacja\nzagrożenie wybuchowe\npenetracja wody\nnormalne i anormalne wahania energii zasilającej\nryzyko porażenia elektrycznego\nwytrzymałość na ciśnienie\nniezawodność urządzeń zabezpieczających, kontroli i regulacji\nwzajemne odziaływanie urządzeń sterujących i zabezpieczających\nzabezpieczenia elementów ustawionych przez producenta\nurządzenia kontrolne i nastawcze\nwypływ niespalonego gazu\nnieszczelności\nakumulacja gazu w urządzeniu i w pomieszczeniu\nbezpieczeństwo zapłonu\njakość i stabilność spalania\nszczelność układu spalinowego\nwypływ spalin do pomieszczenia w przypadku zakłóceń ciągu\ntemperatury nagrzania elementów Higieniczność elementów stykających się z wodą pitną i żywnością Racjonalne zużycie energii PN-EN 303-3 | PN-EN 416 z wyłączeniem punktów 7.1 ; 7.2 ; 7.3 ; 7.4 ; 7.5 | PN-EN 419 z wyłączeniem punktu 7 | PN-EN 449 | PN-EN 461 | PN-EN 15502-1 | PN-EN 15502-2-1 z wyłączeniem punktów 8.102 ; 8.103 | PN-EN 15502-2-2 | PN-EN 484 | PN-EN 497 | PN-EN 498 | PN-EN 509 | PN-EN 521 | PN-EN 613 | PN-EN 624 | PN-EN 732 | PN-EN 751-1 | PN-EN 751-2 | PN-EN 751-3 | PN-EN 89 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 437 | PN-EN 14829 | PN-EN 17082 | PN-EN 17175 Urzadzenia spalajace paliwa gazowe uzywane do gotowania, ogrzewania, wytwarzania goracej wody, chlodzenia, oswietlania , prania lub zmywania i w odpowiednich przypadkach majacych temperature wody nie przekraczajaca 105°C palniki z wymuszonym ciagiem oraz urzadzenia grzewcze przeznaczone do wyposazenia w takie palniki, (bez urzadzen przemyslowych) E, Urzadzenia zabezpieczajace, urzadzenia kontroli lub urzadzenia regulacyjne i podzespoly oddzielnie zbywane i zaprojektowane w celu przylaczenia do urzadzenia spalajacego paliwo gazowe lub po zmontowaniu tworzace takie urzadzenie, (bez urzadzen przemyslowych) E Cechy i wlasciwosci do oceny bezpieczenstwa dzialania:\nZakres:\nfunkcjonalnosc armatury\nsprawdzenie materialow\nstabilnosc mechaniczna\nkondensacja\nzagrozenie wybuchowe\npenetracja wody\nnormalne i anormalne wahania energii zasilajacej\nryzyko porazenia elektrycznego\nwytrzymalosc na cisnienie\nniezawodnosc urzadzen zabezpieczajacych, kontroli i regulacji\nwzajemne odzialywanie urzadzen sterujacych i zabezpieczajacych\nzabezpieczenia elementow ustawionych przez producenta\nurzadzenia kontrolne i nastawcze\nwyplyw niespalonego gazu\nnieszczelnosci\nakumulacja gazu w urzadzeniu i w pomieszczeniu\nbezpieczenstwo zaplonu\njakosc i stabilnosc spalania\nszczelnosc ukladu spalinowego\nwyplyw spalin do pomieszczenia w przypadku zaklocen ciagu\ntemperatury nagrzania elementow Higienicznosc elementow stykajacych sie z woda pitna i zywnoscia Racjonalne zuzycie energii PN-EN 303-3 | PN-EN 416 z wylaczeniem punktow 7.1 ; 7.2 ; 7.3 ; 7.4 ; 7.5 | PN-EN 419 z wylaczeniem punktu 7 | PN-EN 449 | PN-EN 461 | PN-EN 15502-1 | PN-EN 15502-2-1 z wylaczeniem punktow 8.102 ; 8.103 | PN-EN 15502-2-2 | PN-EN 484 | PN-EN 497 | PN-EN 498 | PN-EN 509 | PN-EN 521 | PN-EN 613 | PN-EN 624 | PN-EN 732 | PN-EN 751-1 | PN-EN 751-2 | PN-EN 751-3 | PN-EN 89 z wylaczeniem punktow : 8.7 i 8.8 | PN-EN 437 | PN-EN 14829 | PN-EN 17082 | PN-EN 17175","categories":["materials","petro","water","food"],"row_index":444,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Characteristics and properties for the assessment of operational safety:","parameters_en":[{"name":"functionality of fittings"},{"name":"verification of materials"},{"name":"mechanical stability"},{"name":"condensation"},{"name":"explosion hazard"},{"name":"water penetration"},{"name":"normal and abnormal supply power fluctuations"},{"name":"risk of electric shock"},{"name":"pressure resistance"},{"name":"reliability of safety, control and regulating devices"},{"name":"interaction of control and protective devices"},{"name":"protection of components set by the manufacturer"},{"name":"control and setting devices"},{"name":"release of unburned gas"},{"name":"leaks"},{"name":"gas accumulation in the appliance and in the room"},{"name":"ignition safety"},{"name":"combustion quality and stability"},{"name":"tightness of the flue gas system"},{"name":"spillage of flue gases into the room in the event of draught disturbance"},{"name":"heating temperatures of components Hygiene of components in contact with drinking water and food Rational energy consumption"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Appliances burning gaseous fuels used for cooking, heating, hot water production, refrigeration, lighting, washing or dishwashing and, where applicable, having a water temperature not exceeding 105°C forced draught burners and heating bodies to be equipped with such burners, (excluding industrial appliances) E, Safety devices, controlling devices or regulating devices and sub-assemblies marketed separately and designed to be incorporated into an appliance burning gaseous fuel or assembled to constitute such an appliance, (excluding industrial appliances) E Characteristics and properties for the assessment of operational safety: Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. functionality of fittings verification of materials mechanical stability condensation explosion hazard water penetration normal and abnormal supply power fluctuations risk of electric shock pressure resistance reliability of safety, control and regulating devices interaction of control and protective devices protection of components set by the manufacturer control and setting devices release of unburned gas leaks gas accumulation in the appliance and in the room ignition safety combustion quality and stability tightness of the flue gas system spillage of flue gases into the room in the event of draught disturbance heating temperatures of components Hygiene of components in contact with drinking water and food Rational energy consumption PN-EN 303-3 | PN-EN 416 z wyłączeniem punktów 7.1 ; 7.2 ; 7.3 ; 7.4 ; 7.5 | PN-EN 419 z wyłączeniem punktu 7 | PN-EN 449 | PN-EN 461 | PN-EN 15502-1 | PN-EN 15502-2-1 z wyłączeniem punktów 8.102 ; 8.103 | PN-EN 15502-2-2 | PN-EN 484 | PN-EN 497 | PN-EN 498 | PN-EN 509 | PN-EN 521 | PN-EN 613 | PN-EN 624 | PN-EN 732 | PN-EN 751-1 | PN-EN 751-2 | PN-EN 751-3 | PN-EN 89 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 437 | PN-EN 14829 | PN-EN 17082 | PN-EN 17175","test_object_en":"Appliances burning gaseous fuels used for cooking, heating, hot water production, refrigeration, lighting, washing or dishwashing and, where applicable, having a water temperature not exceeding 105°C forced draught burners and heating bodies to be equipped with such burners, (excluding industrial appliances) E, Safety devices, controlling devices or regulating devices and sub-assemblies marketed separately and designed to be incorporated into an appliance burning gaseous fuel or assembled to constitute such an appliance, (excluding industrial appliances) E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"用于动作安全性评定的特征与性能： 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 阀件的功能性 材料检查 机械稳定性 冷凝 爆炸危险 水的渗入 供电能量的正常与非正常波动 触电风险 耐压强度 安全、控制与调节装置的可靠性 制造商预设元件的防护 控制与整定装置 未燃气体的泄出 泄漏 气体在设备内与房间内的积聚 点火安全性 燃烧质量与稳定性 排烟系统的密封性 抽力受扰时烟气向房间的泄出 元件的加热温度；与饮用水和食品接触元件的卫生性；能源的合理消耗 PN-EN 303-3 | PN-EN 416 z wyłączeniem punktów 7.1 ; 7.2 ; 7.3 ; 7.4 ; 7.5 | PN-EN 419 z wyłączeniem punktu 7 | PN-EN 449 | PN-EN 461 | PN-EN 15502-1 | PN-EN 15502-2-1 z wyłączeniem punktów 8.102 ; 8.103 | PN-EN 15502-2-2 | PN-EN 484 | PN-EN 497 | PN-EN 498 | PN-EN 509 | PN-EN 521 | PN-EN 613 | PN-EN 624 | PN-EN 732 | PN-EN 751-1 | PN-EN 751-2 | PN-EN 751-3 | PN-EN 89 z wyłączeniem punktów : 8.7 i 8.8 | PN-EN 437 | PN-EN 14829 | PN-EN 17082 | PN-EN 17175","methodology_zh":"用于动作安全性评定的特征与性能：","parameters_zh":[{"name":"阀件的功能性"},{"name":"材料检查"},{"name":"机械稳定性"},{"name":"冷凝"},{"name":"爆炸危险"},{"name":"水的渗入"},{"name":"供电能量的正常与非正常波动"},{"name":"触电风险"},{"name":"耐压强度"},{"name":"安全、控制与调节装置的可靠性"},{"name":"wzajemne odziaływanie urządzeń sterujących i zabezpieczających"},{"name":"制造商预设元件的防护"},{"name":"控制与整定装置"},{"name":"未燃气体的泄出"},{"name":"泄漏"},{"name":"气体在设备内与房间内的积聚"},{"name":"点火安全性"},{"name":"燃烧质量与稳定性"},{"name":"排烟系统的密封性"},{"name":"抽力受扰时烟气向房间的泄出"},{"name":"元件的加热温度；与饮用水和食品接触元件的卫生性；能源的合理消耗"}]},{"_id":"6a7d75f9441eff5f15648998","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Mechanizm zapalania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mechanizm zapalania","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Mechanizm zapalania PN-EN 9994 Zapalniczki i zapalarki gazowe E Mechanizm zapalania PN-EN 9994","categories":["other"],"row_index":445,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Ignition mechanism","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Ignition mechanism Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f15648999","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Wysokość płomienia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wysokość płomienia","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Wysokość płomienia PN-EN 9994 Zapalniczki i zapalarki gazowe E Wysokosc plomienia PN-EN 9994","categories":["other"],"row_index":446,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Flame height","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Flame height Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f1564899a","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Nastawianie wysokości płomienia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nastawianie wysokości płomienia","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Nastawianie wysokości płomienia PN-EN 9994 Zapalniczki i zapalarki gazowe E Nastawianie wysokosci plomienia PN-EN 9994","categories":["other"],"row_index":447,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Flame height adjustment","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Flame height adjustment Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f1564899b","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Odporność na plucie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na plucie","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Odporność na plucie PN-EN 9994 Zapalniczki i zapalarki gazowe E Odpornosc na plucie PN-EN 9994","categories":["other"],"row_index":448,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to spitting","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Resistance to spitting Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f1564899c","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Wygaszanie płomienia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wygaszanie płomienia","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Wygaszanie płomienia PN-EN 9994 Zapalniczki i zapalarki gazowe E Wygaszanie plomienia PN-EN 9994","categories":["other"],"row_index":449,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Flame extinguishment","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Flame extinguishment Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f1564899d","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Obj. Rezerwa pojemności","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Obj. Rezerwa pojemności","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Obj. Rezerwa pojemności PN-EN 9994 Zapalniczki i zapalarki gazowe E Obj. Rezerwa pojemnosci PN-EN 9994","categories":["other"],"row_index":450,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Vol. Capacity reserve","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Vol. Capacity reserve Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f1564899e","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Wykończenie zewnętrzne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wykończenie zewnętrzne","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Wykończenie zewnętrzne PN-EN 9994 Zapalniczki i zapalarki gazowe E Wykonczenie zewnetrzne PN-EN 9994","categories":["other"],"row_index":451,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"External finishing","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E External finishing Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f1564899f","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Dost. pojemnika do rodzaju gazu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Dost. pojemnika do rodzaju gazu","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Dost. pojemnika do rodzaju gazu PN-EN 9994 Zapalniczki i zapalarki gazowe E Dost. pojemnika do rodzaju gazu PN-EN 9994","categories":["other"],"row_index":452,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Suitability of the container for the type of gas","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Suitability of the container for the type of gas Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f156489a0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Odporność na ubytek paliwa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na ubytek paliwa","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Odporność na ubytek paliwa PN-EN 9994 Zapalniczki i zapalarki gazowe E Odpornosc na ubytek paliwa PN-EN 9994","categories":["petro"],"row_index":453,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to fuel loss","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Resistance to fuel loss Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f156489a1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Odporność na podwyższoną temperaturę","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na podwyższoną temperaturę","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Odporność na podwyższoną temperaturę PN-EN 9994 Zapalniczki i zapalarki gazowe E Odpornosc na podwyzszona temperature PN-EN 9994","categories":["other"],"row_index":454,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to elevated temperature","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Resistance to elevated temperature Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f156489a2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Odporność na ciśnienie wewnętrzne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na ciśnienie wewnętrzne","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Odporność na ciśnienie wewnętrzne PN-EN 9994 Zapalniczki i zapalarki gazowe E Odpornosc na cisnienie wewnetrzne PN-EN 9994","categories":["other"],"row_index":455,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to internal pressure","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Resistance to internal pressure Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f156489a3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Odporność na palący się płomień","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na palący się płomień","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Odporność na palący się płomień PN-EN 9994 Zapalniczki i zapalarki gazowe E Odpornosc na palacy sie plomien PN-EN 9994","categories":["other"],"row_index":456,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to a burning flame","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Resistance to a burning flame Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f156489a4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Odporność na palenie okresowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na palenie okresowe","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Odporność na palenie okresowe PN-EN 9994 Zapalniczki i zapalarki gazowe E Odpornosc na palenie okresowe PN-EN 9994","categories":["other"],"row_index":457,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to intermittent burning","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Resistance to intermittent burning Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f156489a5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Odporność na palenie ciągłe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na palenie ciągłe","reference":"PN-EN 9994","norm_bases":["PN-EN 9994"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Odporność na palenie ciągłe PN-EN 9994 Zapalniczki i zapalarki gazowe E Odpornosc na palenie ciagle PN-EN 9994","categories":["other"],"row_index":458,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to continuous burning","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Resistance to continuous burning Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 9994","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 9994","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f156489a6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Zapalniczki i zapalarki gazowe E","methodology":"Zabezpieczenie zapalania zapalniczek przed dziećmi","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zabezpieczenie zapalania zapalniczek przed dziećmi","reference":"PN-EN 13869","norm_bases":["PN-EN 13869"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Zapalniczki i zapalarki gazowe E Zabezpieczenie zapalania zapalniczek przed dziećmi PN-EN 13869 Zapalniczki i zapalarki gazowe E Zabezpieczenie zapalania zapalniczek przed dziecmi PN-EN 13869","categories":["other"],"row_index":459,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Child resistance of lighter ignition","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Gas lighters and igniters E Child resistance of lighter ignition Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 13869","test_object_en":"Gas lighters and igniters E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"打火机与气体点火器 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 13869","test_object_zh":"打火机与气体点火器 E"},{"_id":"6a7d75f9441eff5f156489a7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Wytrzymałość mechaniczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość mechaniczna","reference":"PN-EN 1859 | PN-EN 14989-2","norm_bases":["PN-EN 1859","PN-EN 14989-2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Wytrzymałość mechaniczna PN-EN 1859 | PN-EN 14989-2 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Wytrzymalosc mechaniczna PN-EN 1859 | PN-EN 14989-2","categories":["materials"],"row_index":460,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Mechanical strength","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Mechanical strength Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1859 | PN-EN 14989-2","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","methodology_zh":"机械强度","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 机械强度 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1859 | PN-EN 14989-2","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489a8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Szczelność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność","reference":"PN-EN 1859 | PN-EN 14989-2","norm_bases":["PN-EN 1859","PN-EN 14989-2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Szczelność PN-EN 1859 | PN-EN 14989-2 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Szczelnosc PN-EN 1859 | PN-EN 14989-2","categories":["materials"],"row_index":461,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Leak tightness","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Leak tightness Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1859 | PN-EN 14989-2","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 密封性 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1859 | PN-EN 14989-2","methodology_zh":"密封性","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489a9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Cieplne zachowanie komina","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cieplne zachowanie komina","reference":"PN-EN 1859 | PN-EN 14989-2","norm_bases":["PN-EN 1859","PN-EN 14989-2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Cieplne zachowanie komina PN-EN 1859 | PN-EN 14989-2 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Cieplne zachowanie komina PN-EN 1859 | PN-EN 14989-2","categories":["materials"],"row_index":462,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Thermal performance of the chimney","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Thermal performance of the chimney Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1859 | PN-EN 14989-2","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1859 | PN-EN 14989-2","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489aa","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Wytrzymałość termiczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość termiczna","reference":"PN-EN 1859 | PN-EN 14989-2","norm_bases":["PN-EN 1859","PN-EN 14989-2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Wytrzymałość termiczna PN-EN 1859 | PN-EN 14989-2 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Wytrzymalosc termiczna PN-EN 1859 | PN-EN 14989-2","categories":["materials"],"row_index":463,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Thermal strength","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Thermal strength Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1859 | PN-EN 14989-2","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1859 | PN-EN 14989-2","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489ab","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Odporność na dyfuzję pary wodnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na dyfuzję pary wodnej","reference":"PN-EN 1859 | PN-EN 14989-2","norm_bases":["PN-EN 1859","PN-EN 14989-2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Odporność na dyfuzję pary wodnej PN-EN 1859 | PN-EN 14989-2 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Odpornosc na dyfuzje pary wodnej PN-EN 1859 | PN-EN 14989-2","categories":["materials"],"row_index":464,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to water vapour diffusion","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Resistance to water vapour diffusion Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1859 | PN-EN 14989-2","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1859 | PN-EN 14989-2","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489ac","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Odporność na kondensat gazu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na kondensat gazu","reference":"PN-EN 1859 | PN-EN 14989-2","norm_bases":["PN-EN 1859","PN-EN 14989-2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Odporność na kondensat gazu PN-EN 1859 | PN-EN 14989-2 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Odpornosc na kondensat gazu PN-EN 1859 | PN-EN 14989-2","categories":["materials"],"row_index":465,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to gas condensate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Resistance to gas condensate Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1859 | PN-EN 14989-2","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1859 | PN-EN 14989-2","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489ad","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Odporność na przenikanie wody deszczowej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na przenikanie wody deszczowej","reference":"PN-EN 1859 | PN-EN 14989-2","norm_bases":["PN-EN 1859","PN-EN 14989-2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Odporność na przenikanie wody deszczowej PN-EN 1859 | PN-EN 14989-2 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Odpornosc na przenikanie wody deszczowej PN-EN 1859 | PN-EN 14989-2","categories":["materials","water"],"row_index":466,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to rainwater penetration","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Resistance to rainwater penetration Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1859 | PN-EN 14989-2","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1859 | PN-EN 14989-2","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489ae","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Opory przepływu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Opory przepływu","reference":"PN-EN 1859 | PN-EN 14989-2","norm_bases":["PN-EN 1859","PN-EN 14989-2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Opory przepływu PN-EN 1859 | PN-EN 14989-2 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Opory przeplywu PN-EN 1859 | PN-EN 14989-2","categories":["materials"],"row_index":467,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Flow resistance","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Flow resistance Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1859 | PN-EN 14989-2","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1859 | PN-EN 14989-2","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489af","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Aerodynamiczne opory zakończeń komina","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Aerodynamiczne opory zakończeń komina","reference":"PN-EN 1859 | PN-EN 14989-2","norm_bases":["PN-EN 1859","PN-EN 14989-2"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Aerodynamiczne opory zakończeń komina PN-EN 1859 | PN-EN 14989-2 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Aerodynamiczne opory zakonczen komina PN-EN 1859 | PN-EN 14989-2","categories":["materials"],"row_index":468,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Aerodynamic resistance of chimney terminals","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Aerodynamic resistance of chimney terminals Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1859 | PN-EN 14989-2","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1859 | PN-EN 14989-2","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489b0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E","methodology":"Badanie ogniowe małych kominów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie ogniowe małych kominów","reference":"PN-B-02870","norm_bases":["PN-B-02870"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kominy metalowe, Metalowe kanały wewnętrzne i metalowe łączniki E Badanie ogniowe małych kominów PN-B-02870 Kominy metalowe, Metalowe kanaly wewnetrzne i metalowe laczniki E Badanie ogniowe malych kominow PN-B-02870","categories":["materials"],"row_index":469,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Fire test of small chimneys","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E Fire test of small chimneys Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-B-02870","test_object_en":"Metal chimneys, Metal internal flue liners and metal connecting flue pipes E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"金属烟囱、金属内烟道与金属连接件 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-B-02870","test_object_zh":"金属烟囱、金属内烟道与金属连接件 E"},{"_id":"6a7d75f9441eff5f156489b1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Cieplne zachowanie komina","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cieplne zachowanie komina","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Cieplne zachowanie komina PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Cieplne zachowanie komina PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":470,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Thermal performance of the chimney","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Thermal performance of the chimney Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489b2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Wytrzymałość termiczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość termiczna","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Wytrzymałość termiczna PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Wytrzymalosc termiczna PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":471,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Thermal strength","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Thermal strength Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489b3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Opory przepływu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Opory przepływu","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Opory przepływu PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Opory przeplywu PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":472,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Flow resistance","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Flow resistance Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489b4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Szczelność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Szczelność PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Szczelnosc PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":473,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Leak tightness","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Leak tightness Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 密封性 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","methodology_zh":"密封性","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489b5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Odporność na ścieranie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na ścieranie","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Odporność na ścieranie PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Odpornosc na scieranie PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":474,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Abrasion resistance","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Abrasion resistance Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 耐磨性 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","methodology_zh":"耐磨性","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489b6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Wytrzymałość na ściskanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Wytrzymałość na ściskanie PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Wytrzymalosc na sciskanie PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":475,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Compressive strength","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Compressive strength Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","methodology_zh":"抗压强度","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 抗压强度 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489b7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Odporność na działanie kondensatu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie kondensatu","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Odporność na działanie kondensatu PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Odpornosc na dzialanie kondensatu PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":476,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to condensate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Resistance to condensate Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489b8","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Wytrzymałość na zginanie pod naporem wiatru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie pod naporem wiatru","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Wytrzymałość na zginanie pod naporem wiatru PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Wytrzymalosc na zginanie pod naporem wiatru PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":477,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Flexural strength under wind load","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Flexural strength under wind load Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489b9","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Wytrzymałość na zginanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Wytrzymałość na zginanie PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Wytrzymalosc na zginanie PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":478,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Flexural strength","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Flexural strength Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 抗弯强度 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","methodology_zh":"抗弯强度","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489ba","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Odporność na przemienne zamarzanie i odmarzanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na przemienne zamarzanie i odmarzanie","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Odporność na przemienne zamarzanie i odmarzanie PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Odpornosc na przemienne zamarzanie i odmarzanie PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":479,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to alternate freezing and thawing","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Resistance to alternate freezing and thawing Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489bb","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Kwasoodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kwasoodporność","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Kwasoodporność PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Kwasoodpornosc PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":480,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Acid resistance","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Acid resistance Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489bc","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Opór cieplny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Opór cieplny","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Opór cieplny PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Opor cieplny PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["construction"],"row_index":481,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Thermal resistance","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Thermal resistance Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 热阻 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E","methodology_zh":"热阻"},{"_id":"6a7d75f9441eff5f156489bd","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Odporność na dyfuzję wody i pary wodnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na dyfuzję wody i pary wodnej","reference":"PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","norm_bases":["PN-EN 1858","PN-EN 1457-1","PN-EN 1457-2","PN-EN 1856-1","PN-EN 1856-2","PN-EN 12446","PN-EN 1857","PN-EN 13502","PN-EN 13069","PN-EN 14989-1"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Odporność na dyfuzję wody i pary wodnej PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Odpornosc na dyfuzje wody i pary wodnej PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","categories":["water","construction"],"row_index":482,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Resistance to water and water vapour diffusion","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Resistance to water and water vapour diffusion Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 1858 | PN-EN 1457-1 | PN-EN 1457-2 | PN-EN 1856-1 | PN-EN 1856-2 | PN-EN 12446 | PN-EN 1857 | PN-EN 13502 | PN-EN 13069 | PN-EN 14989-1","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489be","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E","methodology":"Badanie ogniowe małych kominów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie ogniowe małych kominów","reference":"PN-B-02870","norm_bases":["PN-B-02870"],"lab_section":"Laboratorium Badań Urządzeń Gazowych i Grzewczych (GU-1)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Ceramiczne wewnętrzne przewody kominowe, Części składowe systemów kominowych, Części składowe kominów – obudowy betonowe, Betonowe kanały wewnętrzne, Kształtki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemów kominowych E Badanie ogniowe małych kominów PN-B-02870 Ceramiczne wewnetrzne przewody kominowe, Czesci skladowe systemow kominowych, Czesci skladowe kominow – obudowy betonowe, Betonowe kanaly wewnetrzne, Ksztaltki betonowe, Obudowy betonowe, Ceramiczne nasady kominowe, Gliniane/ceramiczne obudowy systemow kominowych E Badanie ogniowe malych kominow PN-B-02870","categories":["construction"],"row_index":483,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gas and Heating Appliances Testing Laboratory (GU-1)","methodology_en":"Fire test of small chimneys","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E Fire test of small chimneys Gas and Heating Appliances Testing Laboratory (GU-1) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-B-02870","test_object_en":"Ceramic internal chimney flue liners, Components of chimney systems, Chimney components – concrete outer wall elements, Concrete internal flue liners, Concrete fittings, Concrete outer wall elements, Ceramic chimney terminals, Clay/ceramic outer wall elements of chimney systems E","lab_section_zh":"燃气与供暖器具检测实验室（GU-1）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E 燃气与供暖器具检测实验室（GU-1） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-B-02870","test_object_zh":"陶瓷内衬烟道、烟囱系统组件、烟囱组件 － 混凝土外壳、混凝土内烟道、混凝土异形件、混凝土外壳、陶瓷烟囱帽、黏土/陶瓷烟囱系统外壳 E"},{"_id":"6a7d75f9441eff5f156489bf","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Skały","methodology":"Gęstość – metoda helowa","parameters":[{"name":"Zakres","range":"(1,600 – 7,400) g/cm3"},{"name":"Gęstość objętościowa – metoda proszkowa (Dry Flo)"},{"name":"Zakres","range":"(1,500 – 5,000) g/cm3"},{"name":"Porowatość metoda obliczeniowa"}],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość – metoda helowa\nZakres:\nZakres (1,600 – 7,400) g/cm3\nGęstość objętościowa – metoda proszkowa (Dry Flo)\nZakres (1,500 – 5,000) g/cm3\nPorowatość metoda obliczeniowa","reference":"PB-02/SW-1 wydanie 4 z dnia 30.01.2015 r.","norm_bases":["PB-02/SW-1 wydanie 4 z dnia 30.01.2015 r."],"lab_section":"Laboratorium Geofizycznych Parametrów Skał i Płynów Złożowych (SW-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały Gęstość – metoda helowa\nZakres:\nZakres (1,600 – 7,400) g/cm3\nGęstość objętościowa – metoda proszkowa (Dry Flo)\nZakres (1,500 – 5,000) g/cm3\nPorowatość metoda obliczeniowa PB-02/SW-1 wydanie 4 z dnia 30.01.2015 r. Skaly Gestosc – metoda helowa\nZakres:\nZakres (1,600 – 7,400) g/cm3\nGestosc objetosciowa – metoda proszkowa (Dry Flo)\nZakres (1,500 – 5,000) g/cm3\nPorowatosc metoda obliczeniowa PB-02/SW-1 wydanie 4 z dnia 30.01.2015 r.","categories":["other"],"row_index":484,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory of Geophysical Parameters of Rocks and Reservoir Fluids (SW-1)","methodology_en":"Density – helium method","parameters_en":[{"name":"Range","range":"(1,600 – 7,400) g/cm3"},{"name":"Volumetric density – powder method (Dry Flo)"},{"name":"Range","range":"(1,500 – 5,000) g/cm3"},{"name":"Porosity calculation method"}],"search_en":"Rocks Density – helium method Laboratory of Geophysical Parameters of Rocks and Reservoir Fluids (SW-1) Range Volumetric density – powder method (Dry Flo) Range Porosity calculation method PB-02/SW-1 wydanie 4 z dnia 30.01.2015 r.","test_object_en":"Rocks","parameters_zh":[{"name":"范围","range":"(1,600 – 7,400) g/cm3"},{"name":"Gęstość objętościowa – metoda proszkowa (Dry Flo)"},{"name":"范围","range":"(1,500 – 5,000) g/cm3"},{"name":"Porowatość metoda obliczeniowa"}],"search_zh":"岩石 范围 范围 PB-02/SW-1 wydanie 4 z dnia 30.01.2015 r.","test_object_zh":"岩石"},{"_id":"6a7d75f9441eff5f156489c0","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Węgiel, olej opałowy, olej napędowy","methodology":"Ciepło spalania:","parameters":[{"name":"Zakres","range":"(15000 – 48000) J/g"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania:\nZakres (15000 – 48000) J/g\nMetoda kalorymetryczna","reference":"PB-02/SG-1 wydanie 4 z dnia 10.10.2013 r.","norm_bases":["PB-02/SG-1 wydanie 4 z dnia 10.10.2013 r."],"lab_section":"Laboratorium Geochemii Nafty i Gazu (SG-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgiel, olej opałowy, olej napędowy Ciepło spalania:\nZakres (15000 – 48000) J/g\nMetoda kalorymetryczna PB-02/SG-1 wydanie 4 z dnia 10.10.2013 r. Wegiel, olej opalowy, olej napedowy Cieplo spalania:\nZakres (15000 – 48000) J/g\nMetoda kalorymetryczna PB-02/SG-1 wydanie 4 z dnia 10.10.2013 r.","categories":["petro"],"row_index":485,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Petroleum and Gas Geochemistry Laboratory (SG-1)","methodology_en":"Gross calorific value:","parameters_en":[{"name":"Range","range":"(15000 – 48000) J/g"}],"search_en":"Coal, heating oil, diesel oil Gross calorific value: Calorimetric method Petroleum and Gas Geochemistry Laboratory (SG-1) Range PB-02/SG-1 wydanie 4 z dnia 10.10.2013 r.","technique_en":"Calorimetric method","test_object_en":"Coal, heating oil, diesel oil","parameters_zh":[{"name":"范围","range":"(15000 – 48000) J/g"}],"search_zh":"量热法 石油与天然气地球化学实验室（SG-1） 范围 PB-02/SG-1 wydanie 4 z dnia 10.10.2013 r.","technique_zh":"量热法","lab_section_zh":"石油与天然气地球化学实验室（SG-1）"},{"_id":"6a7d75f9441eff5f156489c1","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Węgiel, sadza, olej opałowy, olej napędowy","methodology":"Oznaczanie zawartości pierwiastka węgla","parameters":[{"name":"Zakres","range":"(30,00 – 99,00) % m/m"}],"technique":"Metoda chromatografii gazowej z detekcją konduktometryczną (GC – TCD)","techniques":["Metoda chromatografii gazowej z detekcją konduktometryczną (GC – TCD)"],"computed":[],"activity":"Oznaczanie zawartości pierwiastka węgla\nZakres (30,00 – 99,00) % m/m\nMetoda chromatografii gazowej z detekcją konduktometryczną (GC – TCD)","reference":"PB-01/SG-1 wydanie 5 z dnia 18.01.2021 r.","norm_bases":["PB-01/SG-1 wydanie 5 z dnia 18.01.2021 r."],"lab_section":"Laboratorium Geochemii Nafty i Gazu (SG-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgiel, sadza, olej opałowy, olej napędowy Oznaczanie zawartości pierwiastka węgla\nZakres (30,00 – 99,00) % m/m\nMetoda chromatografii gazowej z detekcją konduktometryczną (GC – TCD) PB-01/SG-1 wydanie 5 z dnia 18.01.2021 r. Wegiel, sadza, olej opalowy, olej napedowy Oznaczanie zawartosci pierwiastka wegla\nZakres (30,00 – 99,00) % m/m\nMetoda chromatografii gazowej z detekcja konduktometryczna (GC – TCD) PB-01/SG-1 wydanie 5 z dnia 18.01.2021 r.","categories":["petro"],"row_index":486,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Petroleum and Gas Geochemistry Laboratory (SG-1)","methodology_en":"Determination of the content of the element carbon","parameters_en":[{"name":"Range","range":"(30,00 – 99,00) % m/m"}],"search_en":"Coal, carbon black, heating oil, diesel oil Determination of the content of the element carbon Gas chromatography with conductometric detection (GC – TCD) Petroleum and Gas Geochemistry Laboratory (SG-1) Range PB-01/SG-1 wydanie 5 z dnia 18.01.2021 r.","technique_en":"Gas chromatography with conductometric detection (GC – TCD)","test_object_en":"Coal, carbon black, heating oil, diesel oil","parameters_zh":[{"name":"范围","range":"(30,00 – 99,00) % m/m"}],"search_zh":"石油与天然气地球化学实验室（SG-1） 范围 PB-01/SG-1 wydanie 5 z dnia 18.01.2021 r.","lab_section_zh":"石油与天然气地球化学实验室（SG-1）"},{"_id":"6a7d75f9441eff5f156489c2","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gleby, skały, surowce mineralne","methodology":"Oznaczanie zawartości węgla organicznego","parameters":[{"name":"Zakres","range":"(0,05 – 80,00) % m/m"}],"technique":"Metoda spalania wysokotemperaturowego z detekcją w podczerwieni (IR)","techniques":["Metoda spalania wysokotemperaturowego z detekcją w podczerwieni (IR)"],"computed":[],"activity":"Oznaczanie zawartości węgla organicznego\nZakres (0,05 – 80,00) % m/m\nMetoda spalania wysokotemperaturowego z detekcją w podczerwieni (IR)","reference":"PB-03/SG-1 wydanie 1 z dnia 10.02.2015 r.","norm_bases":["PB-03/SG-1 wydanie 1 z dnia 10.02.2015 r."],"lab_section":"Laboratorium Geochemii Nafty i Gazu (SG-1)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleby, skały, surowce mineralne Oznaczanie zawartości węgla organicznego\nZakres (0,05 – 80,00) % m/m\nMetoda spalania wysokotemperaturowego z detekcją w podczerwieni (IR) PB-03/SG-1 wydanie 1 z dnia 10.02.2015 r. Gleby, skaly, surowce mineralne Oznaczanie zawartosci wegla organicznego\nZakres (0,05 – 80,00) % m/m\nMetoda spalania wysokotemperaturowego z detekcja w podczerwieni (IR) PB-03/SG-1 wydanie 1 z dnia 10.02.2015 r.","categories":["other"],"row_index":487,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Petroleum and Gas Geochemistry Laboratory (SG-1)","methodology_en":"Determination of organic carbon content","parameters_en":[{"name":"Range","range":"(0,05 – 80,00) % m/m"}],"search_en":"Soils, rocks, mineral raw materials Determination of organic carbon content High-temperature combustion method with infrared detection (IR) Petroleum and Gas Geochemistry Laboratory (SG-1) Range PB-03/SG-1 wydanie 1 z dnia 10.02.2015 r.","technique_en":"High-temperature combustion method with infrared detection (IR)","test_object_en":"Soils, rocks, mineral raw materials","parameters_zh":[{"name":"范围","range":"(0,05 – 80,00) % m/m"}],"search_zh":"石油与天然气地球化学实验室（SG-1） 范围 PB-03/SG-1 wydanie 1 z dnia 10.02.2015 r.","lab_section_zh":"石油与天然气地球化学实验室（SG-1）"},{"_id":"6a7d75f9441eff5f156489c3","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, Gazy: mieszaniny gazowe (w tym syntetyczne mieszaniny THT)","methodology":"Zawartość tetrahydrotiofenu (THT)","parameters":[{"name":"Zakres","range":"(10,0 – 35,0) mg/m3"},{"name":"Zakres","range":"(2,5 – 10,0) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją pulsacyjno-płomieniowo-fotometryczną (GC-PFPD) i z detekcją elektrochemiczną (GC-ED)","techniques":["Metoda chromatografii gazowej z detekcją pulsacyjno-płomieniowo-fotometryczną (GC-PFPD) i z detekcją elektrochemiczną (GC-ED)"],"computed":[],"activity":"Zawartość tetrahydrotiofenu (THT)\nZakres:\nZakres (10,0 – 35,0) mg/m3\nZakres (2,5 – 10,0) ppm\nMetoda chromatografii gazowej z detekcją pulsacyjno-płomieniowo-fotometryczną (GC-PFPD) i z detekcją elektrochemiczną (GC-ED)","reference":"PB WN-1 wydanie 5 z 20.06.2022 r.","norm_bases":["PB WN-1 wydanie 5 z 20.06.2022 r."],"lab_section":"Zakład Nawaniania Paliw Gazowych (WN)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny, Gazy: mieszaniny gazowe (w tym syntetyczne mieszaniny THT) Zawartość tetrahydrotiofenu (THT)\nZakres:\nZakres (10,0 – 35,0) mg/m3\nZakres (2,5 – 10,0) ppm\nMetoda chromatografii gazowej z detekcją pulsacyjno-płomieniowo-fotometryczną (GC-PFPD) i z detekcją elektrochemiczną (GC-ED) PB WN-1 wydanie 5 z 20.06.2022 r. Paliwa gazowe: gaz ziemny, Gazy: mieszaniny gazowe (w tym syntetyczne mieszaniny THT) Zawartosc tetrahydrotiofenu (THT)\nZakres:\nZakres (10,0 – 35,0) mg/m3\nZakres (2,5 – 10,0) ppm\nMetoda chromatografii gazowej z detekcja pulsacyjno-plomieniowo-fotometryczna (GC-PFPD) i z detekcja elektrochemiczna (GC-ED) PB WN-1 wydanie 5 z 20.06.2022 r.","categories":["petro"],"row_index":488,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gaseous Fuels Odorisation Department (WN)","methodology_en":"Tetrahydrothiophene (THT) content","parameters_en":[{"name":"Range","range":"(10,0 – 35,0) mg/m3"},{"name":"Range","range":"(2,5 – 10,0) ppm"}],"search_en":"Gaseous fuels: natural gas, Gases: gas mixtures (including synthetic THT mixtures) Tetrahydrothiophene (THT) content Gas chromatography with pulsed flame photometric detection (GC-PFPD) and with electrochemical detection (GC-ED) Gaseous Fuels Odorisation Department (WN) Range Range PB WN-1 wydanie 5 z 20.06.2022 r.","technique_en":"Gas chromatography with pulsed flame photometric detection (GC-PFPD) and with electrochemical detection (GC-ED)","test_object_en":"Gaseous fuels: natural gas, Gases: gas mixtures (including synthetic THT mixtures)","parameters_zh":[{"name":"范围","range":"(10,0 – 35,0) mg/m3"},{"name":"范围","range":"(2,5 – 10,0) ppm"}],"search_zh":"范围 范围 PB WN-1 wydanie 5 z 20.06.2022 r."},{"_id":"6a7d75f9441eff5f156489c4","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Gazy: mieszaniny gazowe (w tym syntetyczne mieszaniny gazowe)","methodology":"Zawartość tetrahydrotiofenu (THT)","parameters":[{"name":"Zakres","range":"(15,0 – 75,0) mg/m3"},{"name":"Zakres","range":"(4,0 – 20,0) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją elektrochemiczną (GC-ED)","techniques":["Metoda chromatografii gazowej z detekcją elektrochemiczną (GC-ED)"],"computed":[],"activity":"Zawartość tetrahydrotiofenu (THT)\nZakres:\nZakres (15,0 – 75,0) mg/m3\nZakres (4,0 – 20,0) ppm\nMetoda chromatografii gazowej z detekcją elektrochemiczną (GC-ED)","reference":"PB WN-2 Wydanie 6 z 20.06.2022 r.","norm_bases":["PB WN-2 Wydanie 6 z 20.06.2022 r."],"lab_section":"Zakład Nawaniania Paliw Gazowych (WN)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy: mieszaniny gazowe (w tym syntetyczne mieszaniny gazowe) Zawartość tetrahydrotiofenu (THT)\nZakres:\nZakres (15,0 – 75,0) mg/m3\nZakres (4,0 – 20,0) ppm\nMetoda chromatografii gazowej z detekcją elektrochemiczną (GC-ED) PB WN-2 Wydanie 6 z 20.06.2022 r. Gazy: mieszaniny gazowe (w tym syntetyczne mieszaniny gazowe) Zawartosc tetrahydrotiofenu (THT)\nZakres:\nZakres (15,0 – 75,0) mg/m3\nZakres (4,0 – 20,0) ppm\nMetoda chromatografii gazowej z detekcja elektrochemiczna (GC-ED) PB WN-2 Wydanie 6 z 20.06.2022 r.","categories":["other"],"row_index":489,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Gaseous Fuels Odorisation Department (WN)","methodology_en":"Tetrahydrothiophene (THT) content","parameters_en":[{"name":"Range","range":"(15,0 – 75,0) mg/m3"},{"name":"Range","range":"(4,0 – 20,0) ppm"}],"search_en":"Gases: gas mixtures (including synthetic gas mixtures) Tetrahydrothiophene (THT) content Gas chromatography with electrochemical detection (GC-ED) Gaseous Fuels Odorisation Department (WN) Range Range PB WN-2 Wydanie 6 z 20.06.2022 r.","technique_en":"Gas chromatography with electrochemical detection (GC-ED)","test_object_en":"Gases: gas mixtures (including synthetic gas mixtures)","parameters_zh":[{"name":"范围","range":"(15,0 – 75,0) mg/m3"},{"name":"范围","range":"(4,0 – 20,0) ppm"}],"search_zh":"范围 范围 PB WN-2 Wydanie 6 z 20.06.2022 r."},{"_id":"6a7d75f9441eff5f156489c5","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Rodzaj działalności: OCENA WŁAŚCIWOŚCI, UŻYTKOWYCH NA PODSTAWIE BADAŃ, OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DOKUMENTACJI WYROBU BUDOWLANEGO (System 3)","methodology":"Dokument odniesienia:","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Dokument odniesienia:","reference":"Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.)","norm_bases":["Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.)"],"lab_section":null,"lab_address":null,"regulatory_area":"Laboratorium spełnia wymagania określone w Rozporządzeniu Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, pkt 2, ppkt. 3 rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"Rodzaj działalności: OCENA WŁAŚCIWOŚCI, UŻYTKOWYCH NA PODSTAWIE BADAŃ, OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DOKUMENTACJI WYROBU BUDOWLANEGO (System 3) Dokument odniesienia: Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.) Rodzaj dzialalnosci: OCENA WLASCIWOSCI, UZYTKOWYCH NA PODSTAWIE BADAN, OBLICZEN, TABELARYCZNYCH WARTOSCI LUB OPISOWEJ DOKUMENTACJI WYROBU BUDOWLANEGO (System 3) Dokument odniesienia: Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiajace zharmonizowane warunki wprowadzania do obrotu wyrobow budowlanych i uchylajace dyrektywe Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z pozn. zm.)","categories":["construction"],"row_index":490,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reference document:","regulatory_area_en":"The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope.","search_en":"Type of activity: ASSESSMENT OF PERFORMANCE ON THE BASIS OF TESTING, CALCULATION, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3) Reference document: The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope. Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.)","test_object_en":"Type of activity: ASSESSMENT OF PERFORMANCE ON THE BASIS OF TESTING, CALCULATION, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3)","methodology_zh":"参考文件：","regulatory_area_zh":"本实验室在所开展活动范围内符合2011年3月9日第305/2011号条例对检测实验室所规定的要求（附件V，第2条第3款）","search_zh":"参考文件： 本实验室在所开展活动范围内符合2011年3月9日第305/2011号条例对检测实验室所规定的要求（附件V，第2条第3款） Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.)"},{"_id":"6a7d75f9441eff5f156489c6","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"Numer decyzji Komisji","methodology":"Wyrób(y)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wyrób(y)","reference":"Zharmonizowane specyfikacje techniczne","norm_bases":["Zharmonizowane specyfikacje techniczne"],"lab_section":null,"lab_address":null,"regulatory_area":"Laboratorium spełnia wymagania określone w Rozporządzeniu Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, pkt 2, ppkt. 3 rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"Numer decyzji Komisji Wyrób(y) Zharmonizowane specyfikacje techniczne Numer decyzji Komisji Wyrob(y) Zharmonizowane specyfikacje techniczne","categories":["other"],"row_index":491,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Product(s)","regulatory_area_en":"The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope.","search_en":"Commission decision number Product(s) The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope. Zharmonizowane specyfikacje techniczne","test_object_en":"Commission decision number","methodology_zh":"制品","search_zh":"委员会决定编号 制品 本实验室在所开展活动范围内符合2011年3月9日第305/2011号条例对检测实验室所规定的要求（附件V，第2条第3款） Zharmonizowane specyfikacje techniczne","test_object_zh":"委员会决定编号","regulatory_area_zh":"本实验室在所开展活动范围内符合2011年3月9日第305/2011号条例对检测实验室所规定的要求（附件V，第2条第3款）"},{"_id":"6a7d75f9441eff5f156489c7","lab_id":"69ad52a3de79e566650fb0e1","country":"PL","accr_number":"AB 041","accr_body":"PCA","test_object":"99/471/EC","methodology":"Urządzenia do ogrzewania pomieszczeń na paliwa stałe i ciekłe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Urządzenia do ogrzewania pomieszczeń na paliwa stałe i ciekłe","reference":"EN 15250:2007 | EN 16510-2-1 :2022 | EN 16510-2-2 :2022 | EN 16510-2-3 :2022 | EN 16510-2-6 :2022","norm_bases":["EN 15250:2007","EN 16510-2-1 :2022","EN 16510-2-2 :2022","EN 16510-2-3 :2022","EN 16510-2-6 :2022"],"lab_section":null,"lab_address":null,"regulatory_area":"Laboratorium spełnia wymagania określone w Rozporządzeniu Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, pkt 2, ppkt. 3 rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"99/471/EC Urządzenia do ogrzewania pomieszczeń na paliwa stałe i ciekłe EN 15250:2007 | EN 16510-2-1 :2022 | EN 16510-2-2 :2022 | EN 16510-2-3 :2022 | EN 16510-2-6 :2022 99/471/EC Urzadzenia do ogrzewania pomieszczen na paliwa stale i ciekle EN 15250:2007 | EN 16510-2-1 :2022 | EN 16510-2-2 :2022 | EN 16510-2-3 :2022 | EN 16510-2-6 :2022","categories":["petro"],"row_index":492,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Space heaters fired with solid and liquid fuels","regulatory_area_en":"The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope.","search_en":"99/471/EC Space heaters fired with solid and liquid fuels The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope. EN 15250:2007 | EN 16510-2-1 :2022 | EN 16510-2-2 :2022 | EN 16510-2-3 :2022 | EN 16510-2-6 :2022","test_object_en":"99/471/EC","methodology_zh":"固体与液体燃料房间供暖器具","regulatory_area_zh":"本实验室在所开展活动范围内符合2011年3月9日第305/2011号条例对检测实验室所规定的要求（附件V，第2条第3款）","search_zh":"固体与液体燃料房间供暖器具 本实验室在所开展活动范围内符合2011年3月9日第305/2011号条例对检测实验室所规定的要求（附件V，第2条第3款） EN 15250:2007 | EN 16510-2-1 :2022 | EN 16510-2-2 :2022 | EN 16510-2-3 :2022 | EN 16510-2-6 :2022"}],"has_pdf":true}