🇵🇱 SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT ELEKTROTECHNIKI PL
ConstructionMaterials & polymersElectronics & EMC
SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT ELEKTROTECHNIKI is a laboratory accredited by PCA under number AB 022 (Warszawa, Poland). Its accreditation scope covers 58 test methods in the following areas: Construction, Materials & polymers, Electronics & EMC. Test objects include: Low-voltage electrical machines and equipment, including lighting,…, Low-voltage electrical machines and equipment, including lighting a…, Electrotechnical products, Double-capped fluorescent lamps.
At a glance
- Accreditation number: PCA AB 022
- Methods in scope: 58
- Types of test objects: 34
- City: Warszawa, Poland
- Accreditation number
- AB 022
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE I WZORCUJĄCE URZĄDZEŃ ELEKTRYCZNYCH, ul. Pożaryskiego 28, 04-703 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (34)
- Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) — 11 methods
- Low-voltage electrical machines and equipment, including lighting and information technology equipment — 7 methods
- Electrotechnical products — 4 methods
- Double-capped fluorescent lamps — 2 methods
- Emergency luminaires — 2 methods
- Equipment for lamps — 2 methods
- Luminaires — 2 methods
- Rooms and circulation routes of buildings — 2 methods
- Cable reels for household and similar applications Plugs and socket-outlets for household and similar use Socket-outlets for appliances Switched socket-outlets without interlock for fixed installations Plug adaptors — 1 method
- Computer and office equipment, hand-held, table-mounted or floor-standing at a distance from the wall greater than 1,5 m (except typewriters, teleprinters and keyboards) — 1 method
- DC and AC electronic ballasts — 1 method
- Discharge lamps (excluding fluorescent lamps) — 1 method
- Electric toys — 1 method
- Electrical appliances for household and similar use — 1 method
- Halogen lamps — 1 method
- and 19 more
Accreditation scope — test methods (58)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Tungsten filament lamps for domestic and similar general lighting purposes | Durability of marking Protection against accidental contact in screw lampholders Temperature rise of the lamp cap Torsion strength Insulation resistance Access to accidentally live parts Creepage distances Withstand to overvoltage pulse Durability Interchangeability | PN-EN 60432-1:2001 PN-EN 60432-1:2001/A1:2006 PN-EN 60432-1:2001/A2:2012 | ||
| 2 | Halogen lamps for domestic and similar general lighting purposes | Durability of marking Protection against accidental contact in screw lampholders Temperature rise of the lamp cap Torsion strength Insulation resistance Access to accidentally live parts Creepage distances Safety at end of life Interchangeability | PN-EN 60432-2:2001 PN-EN 60432-2:2001/A1:2007 PN-EN 60432-2:2001/A2:2012 | ||
| 3 | Halogen lamps (other than for vehicles) | Durability of marking Clearances Linear dimensions Safety at end of life | PN-EN 60432-3:2013-06 | ||
| 4 | Discharge lamps (excluding fluorescent lamps) | Durability of marking Linear dimensions Clearances Compatibility of the keys of the cap - lampholder assembly Resistance to tension and torsion Access to accidentally live parts Insulation resistance Dielectric strength Resistance to heat, flame and ignition Pulse height in lamps with an internal ignition circuit | PN-EN 62035:2015-05 PN-EN 62035:2015-05/A1:2019-11 | ||
| 5 | Self-ballasted lamps for general lighting services | Durability of marking Interchangeability Protection against electric shock Insulation resistance and dielectric strength of insulation Torsion strength Cap temperature rise Resistance to heat, flame and ignition Operation in fault condition | PN-EN 60968:2015-12 | ||
| 6 | Double-capped fluorescent lamps | Durability of marking Correctness of construction and fixing Linear dimensions Insulation resistance Dielectric strength Access to accidentally live parts Resistance to heat and fire Clearances Temperature rise of the lamp cap Minimum overall length of the lamp | PN-EN 61195:2005 PN-EN 61195:2005/A1:2013-06 PN-EN 61195:2005/A2:2015-04 | ||
| 7 | Single-capped fluorescent lamps | Durability of marking Correctness of construction and fixing Linear dimensions Keyed caps Insulation resistance Dielectric strength Access to accidentally live parts Resistance to heat and fire Clearance for caps Temperature rise of the lamp cap Resistance to fire and ignition of interference suppression capacitors | PN-EN 61199:2011 PN-EN 61199:2011/A1:2013-06 PN-EN 61199:2011/A2:2015-04 | ||
| 8 | Luminaires | Durability of marking Linear dimensions Mechanical strength Mechanical stability Continuity of protective connections Resistance of protective connections Protection against electric shock Discharge of capacitors Resistance to ingress of dust, solid objects and water Insulation resistance and dielectric strength Creepage distances and clearances Durability Operating temperatures Resistance to heat, fire and tracking Correctness of terminal construction Spatial luminous intensity distribution Luminous flux Change of luminous flux as a function of time Switching capability after failure of the main supply Decrease of luminous flux at high temperature Battery charging current Correct operation of the testing device – simulation of loss of the main supply voltage | PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12 | ||
| 9 | Equipment for lamps | Durability of marking Dimensions and construction of terminals Continuity of protective connections Resistance of protective connections Protection against accidental contact with live parts Moisture resistance and insulation Dielectric strength Thermal endurance of ballast windings Protection against fire and electric shock in single-fault condition Flammability of insulating materials Insulation construction Operation of the device inhibiting or limiting the generation of ignition voltage pulses Current in the lamp circuit Disturbance voltage Creepage distances and clearances Durability of electrical and mechanical connections Resistance to heat, fire and tracking Temperature rises Time to lamp ignition Switching capability Lamp current and luminous flux Supply current Shape of the lamp current waveform Output open-circuit voltage Output circuit current Switching capability after failure of the main supply Operation of the boost charging device Protection against excessive discharge Operation of the indicator Operation of the remote control Resistance to polarity reversal Resistance to a high-voltage pulse Protection against short circuit and overload Operation with a faulty lamp | PN-EN 61347-1:2015-09 PN-EN 61347-1:2015-09/A1:2021-06 | ||
| 10 | Cable reels for household and similar applications Plugs and socket-outlets for household and similar use Socket-outlets for appliances Switched socket-outlets without interlock for fixed installations Plug adaptors | Durability of marking Linear dimensions Protection against electric shock Continuity of protective connections Resistance of protective connections Dimensions and construction of terminals Mechanical strength Voltage Current Power consumption Power factor Type of insulating materials Insulation construction Components – characteristics tested according to the relevant product standards Resistance to ageing, harmful ingress of water and moisture Insulation resistance and dielectric strength Temperature rises Replaceability of flexible cords Resistance to elevated temperature Durability of electrical and mechanical connections Clearances Resistance to heat, fire and tracking | PN-EN 61242:2001 PN-EN 61242:2001/A1:2010 PN-EN 61242:2001/A2:2016-03 PN-EN 61242:2001/A13:2017-05 | ||
| 11 | Electric toys | Power consumption Heating and operation under abnormal conditions Electric strength Resistance to moisture Mechanical strength Dimensions and construction of terminals Electrical voltage Current Type of insulating materials Insulation construction Components – characteristics tested: see the relevant product standards Durability of electrical and mechanical connections Insulation clearances Resistance to high temperature and glow | PN-EN IEC 62115:2020-04 PN-EN IEC 62115:2020-04/A11:2020- 07 | ||
| 12 | Variable message road information signs | Response to mains voltage reduction and mains frequency variation Immunity to temporary overvoltage Electrical safety Emission of electromagnetic disturbances Immunity to electromagnetic disturbances Resistance to mechanical shocks Resistance to water ingress Resistance to ingress of solid objects and dust Resistance to cold Resistance to dry heat Resistance to cyclic damp heat Resistance to temperature changes | PN-EN 12966+A1:2019-02 | ||
| 13 | Train head and tail signal lamp | Directional luminous intensity Colour K factor (calculated) colour | PN-EN 13032-1+A1:2012 PN-EN 15153+A1:2016-12 PN-EN 15153-1:2020-06 | ||
| 14 | Electrical appliances for household and similar use | Protection against access to live parts Starting of motor-operated appliances Power and current input Temperature rise Impulse overvoltage Moisture resistance Leakage current and electric strength Overload protection of transformers and associated circuits Resistance to wear Protection against fire and electric shock under abnormal operation Stability and protection against mechanical hazards Mechanical strength Dimensions and construction of terminals Mechanical strength Electric voltage Type of insulating materials Insulation construction Components – characteristics tested according to the relevant product standards Durability of electrical and mechanical connections Continuity of protective connections Resistance of protective connections Connection to the supply Terminals for external conductors Dimensions and mechanical durability of mechanical and electrical connections Creepage distances, clearances and distances through insulation Resistance to heat, fire and tracking Resistance to corrosion Absolute value of UV and VIS irradiance Effective value of irradiance weighted according to any sensitivity characteristic in the above range Measurement of electromagnetic field exposure | PN-EN IEC 60335-1:2024-04 | ||
| 15 | Medical electrical equipment | Protection against access to live parts Power and current input Temperature rise Impulse overvoltage Moisture resistance Leakage current and electric strength Overload protection of transformers and associated circuits Resistance to wear Protection against fire and electric shock under abnormal operation Stability and protection against mechanical hazards. Mechanical strength Dimensions and construction of terminals Mechanical strength Electric voltage Type of insulating materials Insulation construction Components - characteristics tested according to the relevant product standards Durability of electrical and mechanical connections Continuity of protective connections Resistance of protective connections Connection to the supply Terminals for external conductors Dimensions and mechanical durability of mechanical and electrical connections Creepage distances, clearances and distances through insulation Resistance to heat, fire and tracking Resistance to corrosion Optical radiation power Irradiance Radiance in the range (250÷830) nm Illuminance Luminance Directional luminous intensity General colour rendering index Correlated colour temperature | PN-EN 60601-1:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A2:2022-03 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984 | ||
| 16 | Incandescent lamps | Torsional strength Voltage, current and active power of the lamp under steady-state conditions Luminous flux maintenance factor Temperature rise at the lamp cap Durability of marking Dimensions of bulbs Initial power Initial luminous flux Luminous flux stability Durability Linear dimensions of lamps Linear dimensions of caps and bases Protection against accidental contact Access to accidentally live parts Maximum power Temperature of the pinch, bulb, contact end of the rim Colour chromaticity Correlated colour temperature Colour rendering index | PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A5:2010 PN-EN 60064:2002/A11:2008 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984 | ||
| 17 | Halogen lamps | Torsional strength Voltage, current and active power of the lamp under steady-state conditions Luminous flux maintenance factor Temperature rise at the lamp cap Durability of marking Dimensions of bulbs Initial power Initial luminous flux Luminous flux stability Durability Linear dimensions of lamps Linear dimensions of caps and bases Protection against accidental contact Access to accidentally live parts Maximum power Temperature of the pinch, bulb, contact end of the rim Colour chromaticity Correlated colour temperature Colour rendering index | PN-EN 60357:2003 PN-EN 60357:2003/A1:2008 PN-EN 60357:2003/A2:2009 PN-EN 60357:2003/A3:2011 PN-EN 60357:2003/A11:2016-12 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:20 Publikacja CIE 084:1989 Publikacja CIE 63:1984 | ||
| 18 | Sodium vapour lamps | Durability of lamp marking Lamp dimensions Linear dimensions of caps Protection against accidental contact Access to accidentally live parts Peak value of the starting pulse voltage Lamp voltage, current and active power under stabilized conditions Luminous flux Preheating current Current crest factor Cap temperature rise Resistance to the rectifying effect Chromaticity Colour rendering index Correlated colour temperature | PN-EN 60662:2012 PN-EN 60662:2012 /A11:2019-11 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984 | ||
| 19 | Double-capped fluorescent lamps | Linear dimensions of caps Linear dimensions of lamps Voltage, current and active power of the lamp and cathode resistance under stabilised conditions Luminous flux Colour chromaticity Colour rendering index Correlated colour temperature Luminous flux maintenance factor Durability of marking Temperature rise at the lamp cap Radio interference suppression | PN-EN 60081:2002 PN-EN 60081:2002/A2:2005 PN-EN 60081:2002/A3:2006 PN-EN 60081:2002/A4:2010 PN-EN 60081:2002/A5:2014-02 PN-EN 60081:2002/A6:2018-02 PN-EN 60081:2002/A11:2018-10 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984 | ||
| 20 | Equipment for lamps | Durability of marking Output voltage and current Power consumption Power factor Supply current Lamp current and luminous flux Operation under abnormal conditions Functional characteristics Radio interference suppression Protection against magnetic influences Durability | PN-EN 60921:2005 PN-EN 60921:2005/A1:2006 PN-EN 60923:2006 PN-EN 60923:2006/A1:2006 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60927:2007 PN-EN 60927:2007/A1:2014-04 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 61047:2005 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 | ||
| 21 | Luminaires and light sources with a maximum linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG. | Luminous intensity distribution | PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN IEC 60598-2-22:2022-11 PN-EN 60079-35-2:2012 PN-EN 12966+A1:2019-02 | ||
| 22 | Luminaires with a maximum linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG. | Luminous efficacy | PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 | ||
| 23 | Local lighting luminaires | Illuminance (0÷500) klx | PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN 60079-35-2:2012 | ||
| 24 | Emergency luminaires | Luminance (0÷999900) cd/m2 | PN-EN IEC 60598-2-22:2022-11 | ||
| 25 | Rooms and circulation routes of buildings | Illuminance uniformity | PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05 | ||
| 26 | Rooms and circulation routes of buildings | Chromaticity (0÷1) | PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05 Publikacja CIE 15:2004 | ||
| 27 | Luminous surfaces, light sources | Chromaticity (0÷1) | PN-EN 12966+A1:2019-02 Publikacja CIE 15:2004 | ||
| 28 | Luminaires with a max. linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG. | Overall luminance (0÷999900) cd/m2 | PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 | ||
| 29 | Luminaires | Geometric shielding angle C0÷C360° Y0÷90° | PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12 | ||
| 30 | Signalling and emergency luminaires and special devices and their optical elements; light sources supplied with direct current of max. 20 A and voltage of max. 100 V or supplied with alternating current of max. 20 A. | Spectral parameters in the VIS and UV range (200÷800) nm | PN-EN 60335-2-27:2014-02 PN-EN 60335-2-59:2007 PN-EN 60335-2-59:2007/A2:2010 PN-EN 60335-2-59:2007/A11:2018- 12 PN-EN IEC 60598-2-22:2022-11 | ||
| 31 | Incandescent and discharge light sources with a luminous flux from 10 lm to 500000 lm and a power up to 5 kW, supplied with direct or alternating voltage, with a current up to 20 A and a maximum linear dimension up to 2 m. | Luminous flux (0÷50000) lm | PN-EN 60901:2002 PN-EN 60901:2002/A3:2005 PN-EN 60901:2002/A4:2008 PN-EN 60901:2002/A5:2012 PN-EN 60901:2002/A6:2018-02 PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A11:2008 PN-EN 60064:2002/A5:2010 PN-EN 60969:2002 PN-EN 60188:2004 PN-EN 60188:2004/A11:2019-09 | ||
| 32 | Emergency luminaires | Luminous flux (0÷50000) lm | PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 Publikacja CIE 084:1989 | ||
| 33 | Projection and special lamps, linear fluorescent lamps up to 40 W with a luminous intensity from 1cd to 50000 cd supplied with direct or alternating voltage, with a current not exceeding 20 A. | Directional luminous intensity (0÷500000) cd | PN-EN 12966+A1:2019-02 PN-EN 13032-1+A1:2012 | ||
| 34 | DC and AC electronic ballasts | Ballast lumen factor | PN-EN 61347-2-7:2012 PN-EN 61347-2-7:2012 /A1:2019-11 PN-EN 61347-2-7:2012/A2:2022-11 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 | ||
| 35 | Low-voltage electrical machines and equipment | Sound power level based on sound pressure level measurements Range: (16,5÷100) dB Direct measurement method | PN-EN ISO 1680:2014-02 PN-EN ISO 3744:2011 z wyłączeniem | PN-EN ISO 3743-1:2011 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/AP1:2017-09 PN-EN ISO 3747:2011 PN-EN 62271-202:2014-12 PN-EN 62271-202:2014 -12/ AC1:2015-07 PN-EN 60076-10:2017-01 IEC 60076-10:2016 | ||
| 36 | Computer and office equipment, hand-held, table-mounted or floor-standing at a distance from the wall greater than 1,5 m (except typewriters, teleprinters and keyboards) | Sound power level based on sound pressure level measurements Range: (16,5÷100) dB Direct measurement method | PN-EN ISO 9295:2015-09 PN-EN ISO 7779:2019-03 | ||
| 37 | Low-voltage electrical machines and equipment, including lighting and information technology equipment | Temperature (- 60 ÷ +180) C Humidity up to 98 % | PN-EN 60068-1:2014-06 | ||
| 38 | Low-voltage electrical machines and equipment, including lighting and information technology equipment | Cold | PN-EN 60068-2-1:2009 | ||
| 39 | Low-voltage electrical machines and equipment, including lighting and information technology equipment | Dry heat | PN-EN 60068-2-2:2009 | ||
| 40 | Low-voltage electrical machines and equipment, including lighting and information technology equipment | Damp heat, cyclic (12h+12h) | PN-EN 60068-2-30:2008 | ||
| 41 | Low-voltage electrical machines and equipment, including lighting and information technology equipment | Damp heat, steady state | PN-EN 60068-2-78:2013-11 | ||
| 42 | Low-voltage electrical machines and equipment, including lighting and information technology equipment | Temperature changes | PN-EN IEC 60068-2-14:2024-04 | ||
| 43 | Low-voltage electrical machines and equipment, including lighting and information technology equipment | Resistance to ingress of solid objects, dust and moisture up to IP 68 | PN-EN 60529:2003 PN-EN 60529:2003/A2:2014-07 Z wyłączeniem stopnia ochrony IP X9 (pkt 14) | ||
| 44 | Electrotechnical products | Glow-wire test | PN-EN IEC 60695-2-10:2022-07 PN-EN IEC 60695-2-11:2022-07 PN-EN IEC 60695-2-12:2022-06 PN-EN IEC 60695-2-13:2022-05 | ||
| 45 | Electrotechnical products | Ball pressure test | PN-EN 60695-10-2:2014-10 | ||
| 46 | Electrotechnical products | Needle-flame test | PN-EN 60695-11-5:2017-08 | ||
| 47 | Electrotechnical products | Resistance to tracking currents | PN-EN 60112:2021-07 | ||
| 48 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Emission of conducted disturbances: - emission of continuous conducted disturbances from 9 kHz to 30 MHz - disturbance power (30÷300) MHz - insertion loss of luminaires - voltage fluctuations and flicker - current harmonics up to the 39th harmonic - radiated electromagnetic disturbances of lighting equipment in the range from 9 kHz to 30 MHz | PN-EN IEC 61000-6-3:2021-08 PN-EN 61000-6-4:2008 PN-EN 61000-6-4:2008/A1:2012 PN-EN 61000-6-4:2019-12 PN-EN 55014-1:2021-08 PN-EN 55014-1:2017-06 PN-EN 55015 :2019-10/A11:2020 PN-EN 55015:2013-10/A1:2015-08 PN-EN 55015:2019-11 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 50561-1:2013-12 PN-EN 50121-1:2015-10 PN-EN 50121-1:2017-06 PN-EN 50121-2:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019- 07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019- 10 PN-EN 61000-3-2:2014-10 PN-EN 61000-3-2:2019-04 PN-EN 55022:2011 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN 61326-2-1:2013-07 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej. | ||
| 49 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to electromagnetic disturbances: - electrostatic discharge (ESD) contact and air ± 30kV - electrical fast transients (BURST) - surges (SURGE) - immunity to radio-frequency induced disturbances - voltage dips, short interruptions and voltage variations | PN-EN IEC 55014-2:2021-08 PN-EN IEC 55035:2017-09 PN-EN IEC 55035:2017-09/A11:2020- 09 PN-EN IEC 61000-4-11:2020-11 PN-EN 55024:2011 PN-EN 55024:2011/A1:2015-08 PN-EN 61000-6-1:2008 PN-EN 61000-6-1:2019-03 PN-EN 61000-6-2:2008 PN-EN 61000-6-2:2019-04 PN-EN 61547:2009 PN-EN 50121-1:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019-07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-4:2017-04/A1:2019-07 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-4-2 :2011 PN-EN 61000-4-4:2013-05 PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5 2014-10/A1:2018-01 PN-EN 61000-4-6:2014-04 PN-EN 61000-4-11:2007 PN-EN 61000-4-11:2007/A1:2017-09 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN IEC 61326-2-1:2021-10 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej. | ||
| 50 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to voltage dips and voltage variations at the power port | PN-EN 61000-4-29:2004 | ||
| 51 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to power-frequency magnetic field | PN-EN 61000-4-8:2010 | ||
| 52 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to pulse magnetic field | PN-EN 61000-4-9:2016-11 | ||
| 53 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to damped oscillatory wave | PN-EN 61000-4-18:2009 PN-EN 61000-4-18:2009/A1:2011 PN-EN 61000-4-18:2019-08 | ||
| 54 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to conducted common mode disturbances at frequencies from 0 Hz to 150 kHz | PN-EN 61000-4-16:2016-05 | ||
| 55 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to low-frequency disturbances | PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05 | ||
| 56 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to voltage fluctuations | PN-EN 61000-4-14:2002 +A1:2006+A2:2010 | ||
| 57 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to ripple on the DC input power port | PN-EN 61000-4-17:2004 +A1:2006+A2:2011 | ||
| 58 | Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) | Immunity to power frequency variations | PN-EN 61000-4-28:2004 +A1:2006+A2:2011 | ||
Reference standards (60)
PN-EN 12966+A1:2019-02
PN-EN 12966+A1:2019-02 PN-EN 13032-1+A1:2012
PN-EN 12966+A1:2019-02 Publikacja CIE 15:2004
PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04
PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN 60079-35-2:2012
PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN IEC 60598-2-22:2022-11 PN-EN 60079-35-2:2012 PN-EN 12966+A1:2019-02
PN-EN 13032-1+A1:2012 PN-EN 15153+A1:2016-12 PN-EN 15153-1:2020-06
PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05
PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05 Publikacja CIE 15:2004
PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A5:2010 PN-EN 60064:2002/A11:2008 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984
PN-EN 60068-1:2014-06
PN-EN 60068-2-1:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-30:2008
PN-EN 60068-2-78:2013-11
PN-EN 60081:2002 PN-EN 60081:2002/A2:2005 PN-EN 60081:2002/A3:2006 PN-EN 60081:2002/A4:2010 PN-EN 60081:2002/A5:2014-02 PN-EN 60081:2002/A6:2018-02 PN-EN 60081:2002/A11:2018-10 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984
PN-EN 60112:2021-07
PN-EN 60335-2-27:2014-02 PN-EN 60335-2-59:2007 PN-EN 60335-2-59:2007/A2:2010 PN-EN 60335-2-59:2007/A11:2018- 12 PN-EN IEC 60598-2-22:2022-11
PN-EN 60357:2003 PN-EN 60357:2003/A1:2008 PN-EN 60357:2003/A2:2009 PN-EN 60357:2003/A3:2011 PN-EN 60357:2003/A11:2016-12 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:20 Publikacja CIE 084:1989 Publikacja CIE 63:1984
PN-EN 60432-1:2001 PN-EN 60432-1:2001/A1:2006 PN-EN 60432-1:2001/A2:2012
PN-EN 60432-2:2001 PN-EN 60432-2:2001/A1:2007 PN-EN 60432-2:2001/A2:2012
PN-EN 60432-3:2013-06
PN-EN 60529:2003 PN-EN 60529:2003/A2:2014-07 Z wyłączeniem stopnia ochrony IP X9 (pkt 14)
PN-EN 60601-1:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A2:2022-03 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984
PN-EN 60662:2012 PN-EN 60662:2012 /A11:2019-11 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984
PN-EN 60695-10-2:2014-10
PN-EN 60695-11-5:2017-08
PN-EN 60901:2002 PN-EN 60901:2002/A3:2005 PN-EN 60901:2002/A4:2008 PN-EN 60901:2002/A5:2012 PN-EN 60901:2002/A6:2018-02 PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A11:2008 PN-EN 60064:2002/A5:2010 PN-EN 60969:2002 PN-EN 60188:2004 PN-EN 60188:2004/A11:2019-09
PN-EN 60921:2005 PN-EN 60921:2005/A1:2006 PN-EN 60923:2006 PN-EN 60923:2006/A1:2006 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60927:2007 PN-EN 60927:2007/A1:2014-04 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 61047:2005 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989
PN-EN 60968:2015-12
PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05
PN-EN 61000-4-14:2002 +A1:2006+A2:2010
PN-EN 61000-4-16:2016-05
PN-EN 61000-4-17:2004 +A1:2006+A2:2011
PN-EN 61000-4-18:2009 PN-EN 61000-4-18:2009/A1:2011 PN-EN 61000-4-18:2019-08
PN-EN 61000-4-28:2004 +A1:2006+A2:2011
PN-EN 61000-4-29:2004
PN-EN 61000-4-8:2010
PN-EN 61000-4-9:2016-11
PN-EN 61195:2005 PN-EN 61195:2005/A1:2013-06 PN-EN 61195:2005/A2:2015-04
PN-EN 61199:2011 PN-EN 61199:2011/A1:2013-06 PN-EN 61199:2011/A2:2015-04
PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN 61326-2-1:2013-07 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej.
PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN IEC 61326-2-1:2021-10 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej.
PN-EN 61242:2001 PN-EN 61242:2001/A1:2010 PN-EN 61242:2001/A2:2016-03 PN-EN 61242:2001/A13:2017-05
PN-EN 61347-1:2015-09 PN-EN 61347-1:2015-09/A1:2021-06
PN-EN 61347-2-7:2012 PN-EN 61347-2-7:2012 /A1:2019-11 PN-EN 61347-2-7:2012/A2:2022-11 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989
PN-EN 62035:2015-05 PN-EN 62035:2015-05/A1:2019-11
PN-EN IEC 55014-2:2021-08 PN-EN IEC 55035:2017-09 PN-EN IEC 55035:2017-09/A11:2020- 09 PN-EN IEC 61000-4-11:2020-11 PN-EN 55024:2011 PN-EN 55024:2011/A1:2015-08 PN-EN 61000-6-1:2008 PN-EN 61000-6-1:2019-03 PN-EN 61000-6-2:2008 PN-EN 61000-6-2:2019-04 PN-EN 61547:2009 PN-EN 50121-1:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019-07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-4:2017-04/A1:2019-07 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-4-2 :2011 PN-EN 61000-4-4:2013-05 PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5 2014-10/A1:2018-01 PN-EN 61000-4-6:2014-04 PN-EN 61000-4-11:2007 PN-EN 61000-4-11:2007/A1:2017-09 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04
PN-EN IEC 60068-2-14:2024-04
PN-EN IEC 60335-1:2024-04
PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12
PN-EN IEC 60598-2-22:2022-11
PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04
PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 Publikacja CIE 084:1989
PN-EN IEC 60695-2-10:2022-07 PN-EN IEC 60695-2-11:2022-07 PN-EN IEC 60695-2-12:2022-06 PN-EN IEC 60695-2-13:2022-05
PN-EN IEC 61000-6-3:2021-08 PN-EN 61000-6-4:2008 PN-EN 61000-6-4:2008/A1:2012 PN-EN 61000-6-4:2019-12 PN-EN 55014-1:2021-08 PN-EN 55014-1:2017-06 PN-EN 55015 :2019-10/A11:2020 PN-EN 55015:2013-10/A1:2015-08 PN-EN 55015:2019-11 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 50561-1:2013-12 PN-EN 50121-1:2015-10 PN-EN 50121-1:2017-06 PN-EN 50121-2:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019- 07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019- 10 PN-EN 61000-3-2:2014-10 PN-EN 61000-3-2:2019-04 PN-EN 55022:2011 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04
PN-EN IEC 62115:2020-04 PN-EN IEC 62115:2020-04/A11:2020- 07
PN-EN ISO 1680:2014-02 PN-EN ISO 3744:2011 z wyłączeniem
PN-EN ISO 3743-1:2011 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/AP1:2017-09 PN-EN ISO 3747:2011 PN-EN 62271-202:2014-12 PN-EN 62271-202:2014 -12/ AC1:2015-07 PN-EN 60076-10:2017-01 IEC 60076-10:2016
PN-EN ISO 9295:2015-09 PN-EN ISO 7779:2019-03