{"lab":{"_id":"69ad52a3de79e566650fb0cd","accr_number":"AB 022","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE I WZORCUJĄCE URZĄDZEŃ ELEKTRYCZNYCH, ul. Pożaryskiego 28, 04-703 Warszawa","categories":["construction","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":58,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT ELEKTROTECHNIKI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_022.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - instytut elektrotechniki laboratorium badawcze i wzorcujące urządzeń elektrycznych, ul. pożaryskiego 28, 04-703 warszawa other construction automotive pharma electronics water materials metrology environment","status":"active","updated_at":"2026-03-08T14:50:02.156Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:02.156Z","parse_date":"2026-07-17T16:18:57.148Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://iel.lukasiewicz.gov.pl/kontakt/","fields_of_testing":[{"codes":"A/6; A/25; A/54","pl":"Badania akustyczne wyrobów i wyposażenia elektrycznego, zabawek, wyrobów i wyposażenia elektronicznego","en":"Acoustic tests of of electrical products and equipment, toys, electronic products and equipment"},{"codes":"E/6; E/14; E/16; E/25; E/54","pl":"Badania elektryczne wyrobów i wyposażenia elektrycznego, wyposażenia medycznego, wyrobów optycznych, zabawek, wyrobów i wyposażenia elektronicznego","en":"Electric tests of electrical products and equipment, medical equipment, optical equipment, toys, electronic products and equipment"},{"codes":"F/6; F/13; F/14; F/25; F/54","pl":"Badania kompatybilności elektromagnetycznej (EMC) wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, wyposażenia medycznego, zabawek, wyrobów i wyposażenia elektronicznego","en":"Electromagnetic compatibility (EMC) tests of electrical products and equipment, machinery and devices, medical equipment, toys, electronic products and equipment"},{"codes":"H/6; H/14, H/21; H/54","pl":"Badania ogniowe wyrobów i wyposażenia elektrycznego, wyposażenia medycznego, wyrobów z tworzyw sztucznych, wyrobów i wyposażenia elektronicznego","en":"Fire tests of electrical products and equipment, medical equipment, plastic products, electronic products and equipment"},{"codes":"J/6; J/14; J/16; J/25 J/54","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego, wyposażenia medycznego, wyposażenia optycznego, zabawek, wyrobów i wyposażenia elektronicznego","en":"Mechanical tests of electrical products and equipment, medical equipment, optical equipment, toys, electronic products and equipment"},{"codes":"N/6; N/14; N/5; N/16; N/25; N/54","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, wyposażenia medycznego, obiektów budowlanych, wyposażenia optycznego, zabawek, wyrobów i wyposażenia elektronicznego","en":"Tests of physical properties of electrical, electronic products and equipment, medical equipment,. building items, optical equipment and toys"}],"issue":{"no":"26","date":"12.02.2026"},"map_coord":[52.207157,21.173926],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":41,"construction":13,"materials":5,"water":3,"environment":3,"electronics":2,"automotive":1},"category_scores":{"other":24.72,"construction":2.49,"materials":0.37,"water":0.13,"environment":0.13,"electronics":0.06,"automotive":0.01},"has_zh":true},"methods":[{"_id":"6a5a55f19af9f73f38250eda","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Żarówki z żarnikiem wolframowym do użytku domowego i podobnych ogólnych celów oświetleniowych","test_object_en":"Tungsten filament lamps for domestic and similar general lighting purposes","methodology":"Trwałość znakowania Ochrona przed przypadkowym dotykiem w oprawkach gwintowych Przyrost temperatury trzonka żarówki Wytrzymałość na skręcanie Rezystancja izolacji Dostęp do części przypadkowo czynnych Odstępy izolacyjne powierzchniowe Wytrzymałość na impuls przepięciowy Trwałość Zamienność","methodology_en":"Durability of marking Protection against accidental contact in screw lampholders Temperature rise of the lamp cap Torsion strength Insulation resistance Access to accidentally live parts Creepage distances Withstand to overvoltage pulse Durability Interchangeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Ochrona przed przypadkowym dotykiem w oprawkach gwintowych Przyrost temperatury trzonka żarówki Wytrzymałość na skręcanie Rezystancja izolacji Dostęp do części przypadkowo czynnych Odstępy izolacyjne powierzchniowe Wytrzymałość na impuls przepięciowy Trwałość Zamienność","reference":"PN-EN 60432-1:2001 PN-EN 60432-1:2001/A1:2006 PN-EN 60432-1:2001/A2:2012","norm_bases":["PN-EN 60432-1:2001 PN-EN 60432-1:2001/A1:2006 PN-EN 60432-1:2001/A2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żarówki z żarnikiem wolframowym do użytku domowego i podobnych ogólnych celów oświetleniowych Trwałość znakowania Ochrona przed przypadkowym dotykiem w oprawkach gwintowych Przyrost temperatury trzonka żarówki Wytrzymałość na skręcanie Rezystancja izolacji Dostęp do części przypadkowo czynnych Odstępy izolacyjne powierzchniowe Wytrzymałość na impuls przepięciowy Trwałość Zamienność PN-EN 60432-1:2001 PN-EN 60432-1:2001/A1:2006 PN-EN 60432-1:2001/A2:2012 Zarowki z zarnikiem wolframowym do uzytku domowego i podobnych ogolnych celow oswietleniowych Trwalosc znakowania Ochrona przed przypadkowym dotykiem w oprawkach gwintowych Przyrost temperatury trzonka zarowki Wytrzymalosc na skrecanie Rezystancja izolacji Dostep do czesci przypadkowo czynnych Odstepy izolacyjne powierzchniowe Wytrzymalosc na impuls przepieciowy Trwalosc Zamiennosc PN-EN 60432-1:2001 PN-EN 60432-1:2001/A1:2006 PN-EN 60432-1:2001/A2:2012","categories":["construction"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Tungsten filament lamps for domestic and similar general lighting purposes Durability of marking Protection against accidental contact in screw lampholders Temperature rise of the lamp cap Torsion strength Insulation resistance Access to accidentally live parts Creepage distances Withstand to overvoltage pulse Durability Interchangeability PN-EN 60432-1:2001 PN-EN 60432-1:2001/A1:2006 PN-EN 60432-1:2001/A2:2012"},{"_id":"6a5a55f19af9f73f38250edb","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Żarówki halogenowe do użytku domowego i podobnych ogólnych celów oświetleniowych","test_object_en":"Halogen lamps for domestic and similar general lighting purposes","methodology":"Trwałość znakowania Ochrona przed przypadkowym dotykiem w oprawkach gwintowych Przyrost temperatury trzonka żarówki Wytrzymałość na skręcanie Rezystancja izolacji Dostęp do części przypadkowo czynnych Odstępy izolacyjne powierzchniowe Bezpieczeństwo pod koniec trwałości Zamienność","methodology_en":"Durability of marking Protection against accidental contact in screw lampholders Temperature rise of the lamp cap Torsion strength Insulation resistance Access to accidentally live parts Creepage distances Safety at end of life Interchangeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Ochrona przed przypadkowym dotykiem w oprawkach gwintowych Przyrost temperatury trzonka żarówki Wytrzymałość na skręcanie Rezystancja izolacji Dostęp do części przypadkowo czynnych Odstępy izolacyjne powierzchniowe Bezpieczeństwo pod koniec trwałości Zamienność","reference":"PN-EN 60432-2:2001 PN-EN 60432-2:2001/A1:2007 PN-EN 60432-2:2001/A2:2012","norm_bases":["PN-EN 60432-2:2001 PN-EN 60432-2:2001/A1:2007 PN-EN 60432-2:2001/A2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żarówki halogenowe do użytku domowego i podobnych ogólnych celów oświetleniowych Trwałość znakowania Ochrona przed przypadkowym dotykiem w oprawkach gwintowych Przyrost temperatury trzonka żarówki Wytrzymałość na skręcanie Rezystancja izolacji Dostęp do części przypadkowo czynnych Odstępy izolacyjne powierzchniowe Bezpieczeństwo pod koniec trwałości Zamienność PN-EN 60432-2:2001 PN-EN 60432-2:2001/A1:2007 PN-EN 60432-2:2001/A2:2012 Zarowki halogenowe do uzytku domowego i podobnych ogolnych celow oswietleniowych Trwalosc znakowania Ochrona przed przypadkowym dotykiem w oprawkach gwintowych Przyrost temperatury trzonka zarowki Wytrzymalosc na skrecanie Rezystancja izolacji Dostep do czesci przypadkowo czynnych Odstepy izolacyjne powierzchniowe Bezpieczenstwo pod koniec trwalosci Zamiennosc PN-EN 60432-2:2001 PN-EN 60432-2:2001/A1:2007 PN-EN 60432-2:2001/A2:2012","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Halogen lamps for domestic and similar general lighting purposes Durability of marking Protection against accidental contact in screw lampholders Temperature rise of the lamp cap Torsion strength Insulation resistance Access to accidentally live parts Creepage distances Safety at end of life Interchangeability PN-EN 60432-2:2001 PN-EN 60432-2:2001/A1:2007 PN-EN 60432-2:2001/A2:2012"},{"_id":"6a5a55f19af9f73f38250edc","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Żarówki halogenowe (oprócz pojazdowych)","test_object_en":"Halogen lamps (other than for vehicles)","methodology":"Trwałość znakowania Ostępy izolacyjne Wymiary liniowe Bezpieczeństwo pod koniec trwałości","methodology_en":"Durability of marking Clearances Linear dimensions Safety at end of life","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Ostępy izolacyjne Wymiary liniowe Bezpieczeństwo pod koniec trwałości","reference":"PN-EN 60432-3:2013-06","norm_bases":["PN-EN 60432-3:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żarówki halogenowe (oprócz pojazdowych) Trwałość znakowania Ostępy izolacyjne Wymiary liniowe Bezpieczeństwo pod koniec trwałości PN-EN 60432-3:2013-06 Zarowki halogenowe (oprocz pojazdowych) Trwalosc znakowania Ostepy izolacyjne Wymiary liniowe Bezpieczenstwo pod koniec trwalosci PN-EN 60432-3:2013-06","categories":["construction","automotive"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Halogen lamps (other than for vehicles) Durability of marking Clearances Linear dimensions Safety at end of life PN-EN 60432-3:2013-06"},{"_id":"6a5a55f19af9f73f38250edd","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Lampy wyładowcze (z wyłączeniem świetlówek)","test_object_en":"Discharge lamps (excluding fluorescent lamps)","methodology":"Trwałość znakowania Wymiary liniowe Odstępy izolacyjne Zgodność kluczy zespołu trzonek - oprawka Wytrzymałość na rozciąganie i skręcanie Dostęp do części przypadkowo czynnych Rezystancja izolacji Wytrzymałość elektryczna Odporność na ciepło, płomień i zapłon Wysokość impulsu w lampach z wewnętrznym układem zapłonowym","methodology_en":"Durability of marking Linear dimensions Clearances Compatibility of the keys of the cap - lampholder assembly Resistance to tension and torsion Access to accidentally live parts Insulation resistance Dielectric strength Resistance to heat, flame and ignition Pulse height in lamps with an internal ignition circuit","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Wymiary liniowe Odstępy izolacyjne Zgodność kluczy zespołu trzonek - oprawka Wytrzymałość na rozciąganie i skręcanie Dostęp do części przypadkowo czynnych Rezystancja izolacji Wytrzymałość elektryczna Odporność na ciepło, płomień i zapłon Wysokość impulsu w lampach z wewnętrznym układem zapłonowym","reference":"PN-EN 62035:2015-05 PN-EN 62035:2015-05/A1:2019-11","norm_bases":["PN-EN 62035:2015-05 PN-EN 62035:2015-05/A1:2019-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lampy wyładowcze (z wyłączeniem świetlówek) Trwałość znakowania Wymiary liniowe Odstępy izolacyjne Zgodność kluczy zespołu trzonek - oprawka Wytrzymałość na rozciąganie i skręcanie Dostęp do części przypadkowo czynnych Rezystancja izolacji Wytrzymałość elektryczna Odporność na ciepło, płomień i zapłon Wysokość impulsu w lampach z wewnętrznym układem zapłonowym PN-EN 62035:2015-05 PN-EN 62035:2015-05/A1:2019-11 Lampy wyladowcze (z wylaczeniem swietlowek) Trwalosc znakowania Wymiary liniowe Odstepy izolacyjne Zgodnosc kluczy zespolu trzonek - oprawka Wytrzymalosc na rozciaganie i skrecanie Dostep do czesci przypadkowo czynnych Rezystancja izolacji Wytrzymalosc elektryczna Odpornosc na cieplo, plomien i zaplon Wysokosc impulsu w lampach z wewnetrznym ukladem zaplonowym PN-EN 62035:2015-05 PN-EN 62035:2015-05/A1:2019-11","categories":["construction"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Discharge lamps (excluding fluorescent lamps) Durability of marking Linear dimensions Clearances Compatibility of the keys of the cap - lampholder assembly Resistance to tension and torsion Access to accidentally live parts Insulation resistance Dielectric strength Resistance to heat, flame and ignition Pulse height in lamps with an internal ignition circuit PN-EN 62035:2015-05 PN-EN 62035:2015-05/A1:2019-11"},{"_id":"6a5a55f19af9f73f38250ede","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Lampy samostatecznikowe do ogólnych celów oświetleniowych","test_object_en":"Self-ballasted lamps for general lighting services","methodology":"Trwałość znakowania Zamienność Ochrona przed porażeniem prądem elektrycznym Rezystancja izolacji i wytrzymałość elektryczna izolacji Wytrzymałość na skręcanie Przyrost temperatury trzonka Odporność na ciepło, płomień i zapłon Praca w stanie uszkodzenia","methodology_en":"Durability of marking Interchangeability Protection against electric shock Insulation resistance and dielectric strength of insulation Torsion strength Cap temperature rise Resistance to heat, flame and ignition Operation in fault condition","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Zamienność Ochrona przed porażeniem prądem elektrycznym Rezystancja izolacji i wytrzymałość elektryczna izolacji Wytrzymałość na skręcanie Przyrost temperatury trzonka Odporność na ciepło, płomień i zapłon Praca w stanie uszkodzenia","reference":"PN-EN 60968:2015-12","norm_bases":["PN-EN 60968:2015-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lampy samostatecznikowe do ogólnych celów oświetleniowych Trwałość znakowania Zamienność Ochrona przed porażeniem prądem elektrycznym Rezystancja izolacji i wytrzymałość elektryczna izolacji Wytrzymałość na skręcanie Przyrost temperatury trzonka Odporność na ciepło, płomień i zapłon Praca w stanie uszkodzenia PN-EN 60968:2015-12 Lampy samostatecznikowe do ogolnych celow oswietleniowych Trwalosc znakowania Zamiennosc Ochrona przed porazeniem pradem elektrycznym Rezystancja izolacji i wytrzymalosc elektryczna izolacji Wytrzymalosc na skrecanie Przyrost temperatury trzonka Odpornosc na cieplo, plomien i zaplon Praca w stanie uszkodzenia PN-EN 60968:2015-12","categories":["construction"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-ballasted lamps for general lighting services Durability of marking Interchangeability Protection against electric shock Insulation resistance and dielectric strength of insulation Torsion strength Cap temperature rise Resistance to heat, flame and ignition Operation in fault condition PN-EN 60968:2015-12"},{"_id":"6a5a55f19af9f73f38250edf","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Świetlówki dwutrzonkowe","test_object_en":"Double-capped fluorescent lamps","methodology":"Trwałość znakowania Poprawność konstrukcji i mocowania Wymiary liniowe Rezystancja izolacji Wytrzymałość elektryczna Dostęp do części przypadkowo czynnych Odporność na ciepło i ogień Odstępy izolacyjne Przyrost temperatury trzonka lampy Minimalna długość całkowita lampy","methodology_en":"Durability of marking Correctness of construction and fixing Linear dimensions Insulation resistance Dielectric strength Access to accidentally live parts Resistance to heat and fire Clearances Temperature rise of the lamp cap Minimum overall length of the lamp","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Poprawność konstrukcji i mocowania Wymiary liniowe Rezystancja izolacji Wytrzymałość elektryczna Dostęp do części przypadkowo czynnych Odporność na ciepło i ogień Odstępy izolacyjne Przyrost temperatury trzonka lampy Minimalna długość całkowita lampy","reference":"PN-EN 61195:2005 PN-EN 61195:2005/A1:2013-06 PN-EN 61195:2005/A2:2015-04","norm_bases":["PN-EN 61195:2005 PN-EN 61195:2005/A1:2013-06 PN-EN 61195:2005/A2:2015-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetlówki dwutrzonkowe Trwałość znakowania Poprawność konstrukcji i mocowania Wymiary liniowe Rezystancja izolacji Wytrzymałość elektryczna Dostęp do części przypadkowo czynnych Odporność na ciepło i ogień Odstępy izolacyjne Przyrost temperatury trzonka lampy Minimalna długość całkowita lampy PN-EN 61195:2005 PN-EN 61195:2005/A1:2013-06 PN-EN 61195:2005/A2:2015-04 Swietlowki dwutrzonkowe Trwalosc znakowania Poprawnosc konstrukcji i mocowania Wymiary liniowe Rezystancja izolacji Wytrzymalosc elektryczna Dostep do czesci przypadkowo czynnych Odpornosc na cieplo i ogien Odstepy izolacyjne Przyrost temperatury trzonka lampy Minimalna dlugosc calkowita lampy PN-EN 61195:2005 PN-EN 61195:2005/A1:2013-06 PN-EN 61195:2005/A2:2015-04","categories":["construction"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Double-capped fluorescent lamps Durability of marking Correctness of construction and fixing Linear dimensions Insulation resistance Dielectric strength Access to accidentally live parts Resistance to heat and fire Clearances Temperature rise of the lamp cap Minimum overall length of the lamp PN-EN 61195:2005 PN-EN 61195:2005/A1:2013-06 PN-EN 61195:2005/A2:2015-04"},{"_id":"6a5a55f19af9f73f38250ee0","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Świetlówki jednotrzonkowe","test_object_en":"Single-capped fluorescent lamps","methodology":"Trwałość znakowania Poprawność konstrukcji i mocowania Wymiary liniowe Trzonki z kluczem Rezystancja izolacji Wytrzymałość elektryczna Dostęp do części przypadkowo czynnych Odporność na ciepło i ogień Odstęp izolacyjny dla trzonków Przyrost temperatury trzonka lampy Odporność na ogień i zapłon kondensatorów przeciwzakłóceniowych","methodology_en":"Durability of marking Correctness of construction and fixing Linear dimensions Keyed caps Insulation resistance Dielectric strength Access to accidentally live parts Resistance to heat and fire Clearance for caps Temperature rise of the lamp cap Resistance to fire and ignition of interference suppression capacitors","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Poprawność konstrukcji i mocowania Wymiary liniowe Trzonki z kluczem Rezystancja izolacji Wytrzymałość elektryczna Dostęp do części przypadkowo czynnych Odporność na ciepło i ogień Odstęp izolacyjny dla trzonków Przyrost temperatury trzonka lampy Odporność na ogień i zapłon kondensatorów przeciwzakłóceniowych","reference":"PN-EN 61199:2011 PN-EN 61199:2011/A1:2013-06 PN-EN 61199:2011/A2:2015-04","norm_bases":["PN-EN 61199:2011 PN-EN 61199:2011/A1:2013-06 PN-EN 61199:2011/A2:2015-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetlówki jednotrzonkowe Trwałość znakowania Poprawność konstrukcji i mocowania Wymiary liniowe Trzonki z kluczem Rezystancja izolacji Wytrzymałość elektryczna Dostęp do części przypadkowo czynnych Odporność na ciepło i ogień Odstęp izolacyjny dla trzonków Przyrost temperatury trzonka lampy Odporność na ogień i zapłon kondensatorów przeciwzakłóceniowych PN-EN 61199:2011 PN-EN 61199:2011/A1:2013-06 PN-EN 61199:2011/A2:2015-04 Swietlowki jednotrzonkowe Trwalosc znakowania Poprawnosc konstrukcji i mocowania Wymiary liniowe Trzonki z kluczem Rezystancja izolacji Wytrzymalosc elektryczna Dostep do czesci przypadkowo czynnych Odpornosc na cieplo i ogien Odstep izolacyjny dla trzonkow Przyrost temperatury trzonka lampy Odpornosc na ogien i zaplon kondensatorow przeciwzakloceniowych PN-EN 61199:2011 PN-EN 61199:2011/A1:2013-06 PN-EN 61199:2011/A2:2015-04","categories":["construction"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Single-capped fluorescent lamps Durability of marking Correctness of construction and fixing Linear dimensions Keyed caps Insulation resistance Dielectric strength Access to accidentally live parts Resistance to heat and fire Clearance for caps Temperature rise of the lamp cap Resistance to fire and ignition of interference suppression capacitors PN-EN 61199:2011 PN-EN 61199:2011/A1:2013-06 PN-EN 61199:2011/A2:2015-04"},{"_id":"6a5a55f19af9f73f38250ee1","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Oprawy oświetleniowe","test_object_en":"Luminaires","methodology":"Trwałość znakowania Wymiary liniowe Wytrzymałość mechaniczna Stabilność mechaniczna Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Zabezpieczenie przed porażeniem elektrycznym Rozładowanie kondensatorów Odporność na wnikanie pyłu, ciał stałych i wody Rezystancja i wytrzymałość elektryczna izolacji Odstępy izolacyjne powierzchniowe i powietrzne Trwałość Temperatury pracy Odporność na ciepło, ogień i prądy pełzające Poprawność konstrukcji zacisków Przestrzenny rozsył światłości Strumień świetlny Zmiana strumienia świetlnego w funkcji czasu Zdolność łączeniowa po zaniku zasilania podstawowego Spadek wartości strumienia świetlnego w wysokiej temperaturze Prąd ładowania akumulatorów Poprawność działania urządzenia testującego – symulacja zaniku napięcia podstawowego","methodology_en":"Durability of marking Linear dimensions Mechanical strength Mechanical stability Continuity of protective connections Resistance of protective connections Protection against electric shock Discharge of capacitors Resistance to ingress of dust, solid objects and water Insulation resistance and dielectric strength Creepage distances and clearances Durability Operating temperatures Resistance to heat, fire and tracking Correctness of terminal construction Spatial luminous intensity distribution Luminous flux Change of luminous flux as a function of time Switching capability after failure of the main supply Decrease of luminous flux at high temperature Battery charging current Correct operation of the testing device – simulation of loss of the main supply voltage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Wymiary liniowe Wytrzymałość mechaniczna Stabilność mechaniczna Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Zabezpieczenie przed porażeniem elektrycznym Rozładowanie kondensatorów Odporność na wnikanie pyłu, ciał stałych i wody Rezystancja i wytrzymałość elektryczna izolacji Odstępy izolacyjne powierzchniowe i powietrzne Trwałość Temperatury pracy Odporność na ciepło, ogień i prądy pełzające Poprawność konstrukcji zacisków Przestrzenny rozsył światłości Strumień świetlny Zmiana strumienia świetlnego w funkcji czasu Zdolność łączeniowa po zaniku zasilania podstawowego Spadek wartości strumienia świetlnego w wysokiej temperaturze Prąd ładowania akumulatorów Poprawność działania urządzenia testującego – symulacja zaniku napięcia podstawowego","reference":"PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12","norm_bases":["PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Oprawy oświetleniowe Trwałość znakowania Wymiary liniowe Wytrzymałość mechaniczna Stabilność mechaniczna Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Zabezpieczenie przed porażeniem elektrycznym Rozładowanie kondensatorów Odporność na wnikanie pyłu, ciał stałych i wody Rezystancja i wytrzymałość elektryczna izolacji Odstępy izolacyjne powierzchniowe i powietrzne Trwałość Temperatury pracy Odporność na ciepło, ogień i prądy pełzające Poprawność konstrukcji zacisków Przestrzenny rozsył światłości Strumień świetlny Zmiana strumienia świetlnego w funkcji czasu Zdolność łączeniowa po zaniku zasilania podstawowego Spadek wartości strumienia świetlnego w wysokiej temperaturze Prąd ładowania akumulatorów Poprawność działania urządzenia testującego – symulacja zaniku napięcia podstawowego PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12 Oprawy oswietleniowe Trwalosc znakowania Wymiary liniowe Wytrzymalosc mechaniczna Stabilnosc mechaniczna Ciaglosc polaczen ochronnych Rezystancja polaczen ochronnych Zabezpieczenie przed porazeniem elektrycznym Rozladowanie kondensatorow Odpornosc na wnikanie pylu, cial stalych i wody Rezystancja i wytrzymalosc elektryczna izolacji Odstepy izolacyjne powierzchniowe i powietrzne Trwalosc Temperatury pracy Odpornosc na cieplo, ogien i prady pelzajace Poprawnosc konstrukcji zaciskow Przestrzenny rozsyl swiatlosci Strumien swietlny Zmiana strumienia swietlnego w funkcji czasu Zdolnosc laczeniowa po zaniku zasilania podstawowego Spadek wartosci strumienia swietlnego w wysokiej temperaturze Prad ladowania akumulatorow Poprawnosc dzialania urzadzenia testujacego – symulacja zaniku napiecia podstawowego PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12","categories":["water","construction"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Luminaires Durability of marking Linear dimensions Mechanical strength Mechanical stability Continuity of protective connections Resistance of protective connections Protection against electric shock Discharge of capacitors Resistance to ingress of dust, solid objects and water Insulation resistance and dielectric strength Creepage distances and clearances Durability Operating temperatures Resistance to heat, fire and tracking Correctness of terminal construction Spatial luminous intensity distribution Luminous flux Change of luminous flux as a function of time Switching capability after failure of the main supply Decrease of luminous flux at high temperature Battery charging current Correct operation of the testing device – simulation of loss of the main supply voltage PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12","search_zh":"灯具 PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12","test_object_zh":"灯具"},{"_id":"6a5a55f19af9f73f38250ee2","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Urządzenia do lamp","test_object_en":"Equipment for lamps","methodology":"Trwałość znakowania Wymiary i konstrukcja zacisków Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Ochrona przed przypadkowym dotykiem do części czynnych Odporność na wilgoć i izolacja Wytrzymałość elektryczna Wytrzymałość termiczna uzwojeń stateczników Ochrona przed pożarem i porażeniem prądem elektrycznym w stanie pojedynczego uszkodzenia Palność materiałów izolacyjnych Konstrukcja izolacji Działanie urządzenia wstrzymującego lub ograniczającego generowanie zapłonowych impulsów napięciowych Natężenie prądu w obwodzie lampowym Napięcie zaburzeń Odstępy izolacyjne powierzchniowe i powietrzne Trwałość połączeń elektrycznych i mechanicznych Odporność na ciepło, ogień i prądy pełzające Przyrosty temperatury Czas do zapłonu lampy Zdolność łączeniowa Prąd lampy i strumień świetlny Prąd zasilający Kształt krzywej prądu lampy Napięcie otwartego obwodu wyjściowego Prąd obwodu wyjściowego Zdolność łączeniowa po zaniku zasilania podstawowego Działanie urządzenia doładowującego Zabezpieczenie przed nadmiernym wyładowaniem Działanie wskaźnika Działanie zdalnego sterowania Odporność na zmianę biegunowości Odporność na działanie impulsu wysokonapięciowego Ochrona przed zwarciem i przeciążeniem Działanie z uszkodzoną lampą","methodology_en":"Durability of marking Dimensions and construction of terminals Continuity of protective connections Resistance of protective connections Protection against accidental contact with live parts Moisture resistance and insulation Dielectric strength Thermal endurance of ballast windings Protection against fire and electric shock in single-fault condition Flammability of insulating materials Insulation construction Operation of the device inhibiting or limiting the generation of ignition voltage pulses Current in the lamp circuit Disturbance voltage Creepage distances and clearances Durability of electrical and mechanical connections Resistance to heat, fire and tracking Temperature rises Time to lamp ignition Switching capability Lamp current and luminous flux Supply current Shape of the lamp current waveform Output open-circuit voltage Output circuit current Switching capability after failure of the main supply Operation of the boost charging device Protection against excessive discharge Operation of the indicator Operation of the remote control Resistance to polarity reversal Resistance to a high-voltage pulse Protection against short circuit and overload Operation with a faulty lamp","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Wymiary i konstrukcja zacisków Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Ochrona przed przypadkowym dotykiem do części czynnych Odporność na wilgoć i izolacja Wytrzymałość elektryczna Wytrzymałość termiczna uzwojeń stateczników Ochrona przed pożarem i porażeniem prądem elektrycznym w stanie pojedynczego uszkodzenia Palność materiałów izolacyjnych Konstrukcja izolacji Działanie urządzenia wstrzymującego lub ograniczającego generowanie zapłonowych impulsów napięciowych Natężenie prądu w obwodzie lampowym Napięcie zaburzeń Odstępy izolacyjne powierzchniowe i powietrzne Trwałość połączeń elektrycznych i mechanicznych Odporność na ciepło, ogień i prądy pełzające Przyrosty temperatury Czas do zapłonu lampy Zdolność łączeniowa Prąd lampy i strumień świetlny Prąd zasilający Kształt krzywej prądu lampy Napięcie otwartego obwodu wyjściowego Prąd obwodu wyjściowego Zdolność łączeniowa po zaniku zasilania podstawowego Działanie urządzenia doładowującego Zabezpieczenie przed nadmiernym wyładowaniem Działanie wskaźnika Działanie zdalnego sterowania Odporność na zmianę biegunowości Odporność na działanie impulsu wysokonapięciowego Ochrona przed zwarciem i przeciążeniem Działanie z uszkodzoną lampą","reference":"PN-EN 61347-1:2015-09 PN-EN 61347-1:2015-09/A1:2021-06","norm_bases":["PN-EN 61347-1:2015-09 PN-EN 61347-1:2015-09/A1:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia do lamp Trwałość znakowania Wymiary i konstrukcja zacisków Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Ochrona przed przypadkowym dotykiem do części czynnych Odporność na wilgoć i izolacja Wytrzymałość elektryczna Wytrzymałość termiczna uzwojeń stateczników Ochrona przed pożarem i porażeniem prądem elektrycznym w stanie pojedynczego uszkodzenia Palność materiałów izolacyjnych Konstrukcja izolacji Działanie urządzenia wstrzymującego lub ograniczającego generowanie zapłonowych impulsów napięciowych Natężenie prądu w obwodzie lampowym Napięcie zaburzeń Odstępy izolacyjne powierzchniowe i powietrzne Trwałość połączeń elektrycznych i mechanicznych Odporność na ciepło, ogień i prądy pełzające Przyrosty temperatury Czas do zapłonu lampy Zdolność łączeniowa Prąd lampy i strumień świetlny Prąd zasilający Kształt krzywej prądu lampy Napięcie otwartego obwodu wyjściowego Prąd obwodu wyjściowego Zdolność łączeniowa po zaniku zasilania podstawowego Działanie urządzenia doładowującego Zabezpieczenie przed nadmiernym wyładowaniem Działanie wskaźnika Działanie zdalnego sterowania Odporność na zmianę biegunowości Odporność na działanie impulsu wysokonapięciowego Ochrona przed zwarciem i przeciążeniem Działanie z uszkodzoną lampą PN-EN 61347-1:2015-09 PN-EN 61347-1:2015-09/A1:2021-06 Urzadzenia do lamp Trwalosc znakowania Wymiary i konstrukcja zaciskow Ciaglosc polaczen ochronnych Rezystancja polaczen ochronnych Ochrona przed przypadkowym dotykiem do czesci czynnych Odpornosc na wilgoc i izolacja Wytrzymalosc elektryczna Wytrzymalosc termiczna uzwojen statecznikow Ochrona przed pozarem i porazeniem pradem elektrycznym w stanie pojedynczego uszkodzenia Palnosc materialow izolacyjnych Konstrukcja izolacji Dzialanie urzadzenia wstrzymujacego lub ograniczajacego generowanie zaplonowych impulsow napieciowych Natezenie pradu w obwodzie lampowym Napiecie zaburzen Odstepy izolacyjne powierzchniowe i powietrzne Trwalosc polaczen elektrycznych i mechanicznych Odpornosc na cieplo, ogien i prady pelzajace Przyrosty temperatury Czas do zaplonu lampy Zdolnosc laczeniowa Prad lampy i strumien swietlny Prad zasilajacy Ksztalt krzywej pradu lampy Napiecie otwartego obwodu wyjsciowego Prad obwodu wyjsciowego Zdolnosc laczeniowa po zaniku zasilania podstawowego Dzialanie urzadzenia doladowujacego Zabezpieczenie przed nadmiernym wyladowaniem Dzialanie wskaznika Dzialanie zdalnego sterowania Odpornosc na zmiane biegunowosci Odpornosc na dzialanie impulsu wysokonapieciowego Ochrona przed zwarciem i przeciazeniem Dzialanie z uszkodzona lampa PN-EN 61347-1:2015-09 PN-EN 61347-1:2015-09/A1:2021-06","categories":["materials","construction"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Equipment for lamps Durability of marking Dimensions and construction of terminals Continuity of protective connections Resistance of protective connections Protection against accidental contact with live parts Moisture resistance and insulation Dielectric strength Thermal endurance of ballast windings Protection against fire and electric shock in single-fault condition Flammability of insulating materials Insulation construction Operation of the device inhibiting or limiting the generation of ignition voltage pulses Current in the lamp circuit Disturbance voltage Creepage distances and clearances Durability of electrical and mechanical connections Resistance to heat, fire and tracking Temperature rises Time to lamp ignition Switching capability Lamp current and luminous flux Supply current Shape of the lamp current waveform Output open-circuit voltage Output circuit current Switching capability after failure of the main supply Operation of the boost charging device Protection against excessive discharge Operation of the indicator Operation of the remote control Resistance to polarity reversal Resistance to a high-voltage pulse Protection against short circuit and overload Operation with a faulty lamp PN-EN 61347-1:2015-09 PN-EN 61347-1:2015-09/A1:2021-06"},{"_id":"6a5a55f19af9f73f38250ee3","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Przedłużacze zwijane do zastosowań domowych i podobnych Gniazda wtyczkowe i wtyczki do użytku domowego i podobnego Gniazda wtyczkowe do urządzeń Gniazda wtyczkowe z łącznikiem, bez blokady do instalacji stałych Rozgałęźniki wtyczkowe","test_object_en":"Cable reels for household and similar applications Plugs and socket-outlets for household and similar use Socket-outlets for appliances Switched socket-outlets without interlock for fixed installations Plug adaptors","methodology":"Trwałość znakowania Wymiary liniowe Ochrona przed porażeniem prądem elektrycznym Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Wymiary i konstrukcja zacisków Wytrzymałość mechaniczna Napięcie prądu elektrycznego Natężenie prądu Pobór mocy Współczynnik mocy Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły – badane cechy wg odnośnych norm przedmiotowych Odporność na starzenie, szkodliwe wnikanie wody i wilgoć Rezystancja i wytrzymałość elektryczna izolacji Przyrosty temperatury Przełączalność przewodów giętkich Odporność na podwyższoną temperaturę Trwałość połączeń elektrycznych i mechanicznych Odstępy izolacyjne Odporność na ciepło, ogień i prądy pełzające","methodology_en":"Durability of marking Linear dimensions Protection against electric shock Continuity of protective connections Resistance of protective connections Dimensions and construction of terminals Mechanical strength Voltage Current Power consumption Power factor Type of insulating materials Insulation construction Components – characteristics tested according to the relevant product standards Resistance to ageing, harmful ingress of water and moisture Insulation resistance and dielectric strength Temperature rises Replaceability of flexible cords Resistance to elevated temperature Durability of electrical and mechanical connections Clearances Resistance to heat, fire and tracking","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Wymiary liniowe Ochrona przed porażeniem prądem elektrycznym Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Wymiary i konstrukcja zacisków Wytrzymałość mechaniczna Napięcie prądu elektrycznego Natężenie prądu Pobór mocy Współczynnik mocy Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły – badane cechy wg odnośnych norm przedmiotowych Odporność na starzenie, szkodliwe wnikanie wody i wilgoć Rezystancja i wytrzymałość elektryczna izolacji Przyrosty temperatury Przełączalność przewodów giętkich Odporność na podwyższoną temperaturę Trwałość połączeń elektrycznych i mechanicznych Odstępy izolacyjne Odporność na ciepło, ogień i prądy pełzające","reference":"PN-EN 61242:2001 PN-EN 61242:2001/A1:2010 PN-EN 61242:2001/A2:2016-03 PN-EN 61242:2001/A13:2017-05","norm_bases":["PN-EN 61242:2001 PN-EN 61242:2001/A1:2010 PN-EN 61242:2001/A2:2016-03 PN-EN 61242:2001/A13:2017-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przedłużacze zwijane do zastosowań domowych i podobnych Gniazda wtyczkowe i wtyczki do użytku domowego i podobnego Gniazda wtyczkowe do urządzeń Gniazda wtyczkowe z łącznikiem, bez blokady do instalacji stałych Rozgałęźniki wtyczkowe Trwałość znakowania Wymiary liniowe Ochrona przed porażeniem prądem elektrycznym Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Wymiary i konstrukcja zacisków Wytrzymałość mechaniczna Napięcie prądu elektrycznego Natężenie prądu Pobór mocy Współczynnik mocy Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły – badane cechy wg odnośnych norm przedmiotowych Odporność na starzenie, szkodliwe wnikanie wody i wilgoć Rezystancja i wytrzymałość elektryczna izolacji Przyrosty temperatury Przełączalność przewodów giętkich Odporność na podwyższoną temperaturę Trwałość połączeń elektrycznych i mechanicznych Odstępy izolacyjne Odporność na ciepło, ogień i prądy pełzające PN-EN 61242:2001 PN-EN 61242:2001/A1:2010 PN-EN 61242:2001/A2:2016-03 PN-EN 61242:2001/A13:2017-05 Przedluzacze zwijane do zastosowan domowych i podobnych Gniazda wtyczkowe i wtyczki do uzytku domowego i podobnego Gniazda wtyczkowe do urzadzen Gniazda wtyczkowe z lacznikiem, bez blokady do instalacji stalych Rozgalezniki wtyczkowe Trwalosc znakowania Wymiary liniowe Ochrona przed porazeniem pradem elektrycznym Ciaglosc polaczen ochronnych Rezystancja polaczen ochronnych Wymiary i konstrukcja zaciskow Wytrzymalosc mechaniczna Napiecie pradu elektrycznego Natezenie pradu Pobor mocy Wspolczynnik mocy Rodzaj materialow izolacyjnych Konstrukcja izolacji Podzespoly – badane cechy wg odnosnych norm przedmiotowych Odpornosc na starzenie, szkodliwe wnikanie wody i wilgoc Rezystancja i wytrzymalosc elektryczna izolacji Przyrosty temperatury Przelaczalnosc przewodow gietkich Odpornosc na podwyzszona temperature Trwalosc polaczen elektrycznych i mechanicznych Odstepy izolacyjne Odpornosc na cieplo, ogien i prady pelzajace PN-EN 61242:2001 PN-EN 61242:2001/A1:2010 PN-EN 61242:2001/A2:2016-03 PN-EN 61242:2001/A13:2017-05","categories":["materials","water","construction"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cable reels for household and similar applications Plugs and socket-outlets for household and similar use Socket-outlets for appliances Switched socket-outlets without interlock for fixed installations Plug adaptors Durability of marking Linear dimensions Protection against electric shock Continuity of protective connections Resistance of protective connections Dimensions and construction of terminals Mechanical strength Voltage Current Power consumption Power factor Type of insulating materials Insulation construction Components – characteristics tested according to the relevant product standards Resistance to ageing, harmful ingress of water and moisture Insulation resistance and dielectric strength Temperature rises Replaceability of flexible cords Resistance to elevated temperature Durability of electrical and mechanical connections Clearances Resistance to heat, fire and tracking PN-EN 61242:2001 PN-EN 61242:2001/A1:2010 PN-EN 61242:2001/A2:2016-03 PN-EN 61242:2001/A13:2017-05"},{"_id":"6a5a55f19af9f73f38250ee4","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Zabawki elektryczne","test_object_en":"Electric toys","methodology":"Pobór mocy Nagrzewanie i praca w warunkach nienormalnych Wytrzymałość elektryczna Odporność na wilgoć Wytrzymałość mechaniczna Wymiary i konstrukcja zacisków Napięcie prądu elektrycznego Natężenie prądu Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły – badane cechy: patrz w odnośnych normach przedmiotowych Trwałość połączeń elektrycznych i mechanicznych Odstępy izolacyjne Odporność na wysoką temperaturę i żar","methodology_en":"Power consumption Heating and operation under abnormal conditions Electric strength Resistance to moisture Mechanical strength Dimensions and construction of terminals Electrical voltage Current Type of insulating materials Insulation construction Components – characteristics tested: see the relevant product standards Durability of electrical and mechanical connections Insulation clearances Resistance to high temperature and glow","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobór mocy Nagrzewanie i praca w warunkach nienormalnych Wytrzymałość elektryczna Odporność na wilgoć Wytrzymałość mechaniczna Wymiary i konstrukcja zacisków Napięcie prądu elektrycznego Natężenie prądu Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły – badane cechy: patrz w odnośnych normach przedmiotowych Trwałość połączeń elektrycznych i mechanicznych Odstępy izolacyjne Odporność na wysoką temperaturę i żar","reference":"PN-EN IEC 62115:2020-04 PN-EN IEC 62115:2020-04/A11:2020- 07","norm_bases":["PN-EN IEC 62115:2020-04 PN-EN IEC 62115:2020-04/A11:2020- 07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki elektryczne Pobór mocy Nagrzewanie i praca w warunkach nienormalnych Wytrzymałość elektryczna Odporność na wilgoć Wytrzymałość mechaniczna Wymiary i konstrukcja zacisków Napięcie prądu elektrycznego Natężenie prądu Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły – badane cechy: patrz w odnośnych normach przedmiotowych Trwałość połączeń elektrycznych i mechanicznych Odstępy izolacyjne Odporność na wysoką temperaturę i żar PN-EN IEC 62115:2020-04 PN-EN IEC 62115:2020-04/A11:2020- 07 Zabawki elektryczne Pobor mocy Nagrzewanie i praca w warunkach nienormalnych Wytrzymalosc elektryczna Odpornosc na wilgoc Wytrzymalosc mechaniczna Wymiary i konstrukcja zaciskow Napiecie pradu elektrycznego Natezenie pradu Rodzaj materialow izolacyjnych Konstrukcja izolacji Podzespoly – badane cechy: patrz w odnosnych normach przedmiotowych Trwalosc polaczen elektrycznych i mechanicznych Odstepy izolacyjne Odpornosc na wysoka temperature i zar PN-EN IEC 62115:2020-04 PN-EN IEC 62115:2020-04/A11:2020- 07","categories":["materials","construction"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electric toys Power consumption Heating and operation under abnormal conditions Electric strength Resistance to moisture Mechanical strength Dimensions and construction of terminals Electrical voltage Current Type of insulating materials Insulation construction Components – characteristics tested: see the relevant product standards Durability of electrical and mechanical connections Insulation clearances Resistance to high temperature and glow PN-EN IEC 62115:2020-04 PN-EN IEC 62115:2020-04/A11:2020- 07"},{"_id":"6a5a55f19af9f73f38250ee5","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Drogowe znaki informacyjne o zmiennej treści","test_object_en":"Variable message road information signs","methodology":"Reakcja na obniżenie napięcia i zmianę częstotliwości napięcia sieciowego Odporność na czasowe przepięcie Bezpieczeństwo elektryczne Emisja zaburzeń elektromagnetycznych Odporność na zaburzenia elektromagnetyczne Odporność na udary mechaniczne Odporność na wnikanie wody Odporność na wnikanie ciał stałych i pyłu Odporność na zimno Odporność na suche gorąco Odporność na wilgotne gorąco cykliczne Odporność na zmiany temperatury","methodology_en":"Response to mains voltage reduction and mains frequency variation Immunity to temporary overvoltage Electrical safety Emission of electromagnetic disturbances Immunity to electromagnetic disturbances Resistance to mechanical shocks Resistance to water ingress Resistance to ingress of solid objects and dust Resistance to cold Resistance to dry heat Resistance to cyclic damp heat Resistance to temperature changes","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Reakcja na obniżenie napięcia i zmianę częstotliwości napięcia sieciowego Odporność na czasowe przepięcie Bezpieczeństwo elektryczne Emisja zaburzeń elektromagnetycznych Odporność na zaburzenia elektromagnetyczne Odporność na udary mechaniczne Odporność na wnikanie wody Odporność na wnikanie ciał stałych i pyłu Odporność na zimno Odporność na suche gorąco Odporność na wilgotne gorąco cykliczne Odporność na zmiany temperatury","reference":"PN-EN 12966+A1:2019-02","norm_bases":["PN-EN 12966+A1:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe znaki informacyjne o zmiennej treści Reakcja na obniżenie napięcia i zmianę częstotliwości napięcia sieciowego Odporność na czasowe przepięcie Bezpieczeństwo elektryczne Emisja zaburzeń elektromagnetycznych Odporność na zaburzenia elektromagnetyczne Odporność na udary mechaniczne Odporność na wnikanie wody Odporność na wnikanie ciał stałych i pyłu Odporność na zimno Odporność na suche gorąco Odporność na wilgotne gorąco cykliczne Odporność na zmiany temperatury PN-EN 12966+A1:2019-02 Drogowe znaki informacyjne o zmiennej tresci Reakcja na obnizenie napiecia i zmiane czestotliwosci napiecia sieciowego Odpornosc na czasowe przepiecie Bezpieczenstwo elektryczne Emisja zaburzen elektromagnetycznych Odpornosc na zaburzenia elektromagnetyczne Odpornosc na udary mechaniczne Odpornosc na wnikanie wody Odpornosc na wnikanie cial stalych i pylu Odpornosc na zimno Odpornosc na suche goraco Odpornosc na wilgotne goraco cykliczne Odpornosc na zmiany temperatury PN-EN 12966+A1:2019-02","categories":["water","environment","electronics"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Variable message road information signs Response to mains voltage reduction and mains frequency variation Immunity to temporary overvoltage Electrical safety Emission of electromagnetic disturbances Immunity to electromagnetic disturbances Resistance to mechanical shocks Resistance to water ingress Resistance to ingress of solid objects and dust Resistance to cold Resistance to dry heat Resistance to cyclic damp heat Resistance to temperature changes PN-EN 12966+A1:2019-02"},{"_id":"6a5a55f19af9f73f38250ee6","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Sygnalizator czoła i końca pociągu","test_object_en":"Train head and tail signal lamp","methodology":"Światłość kierunkowa Barwa Współczynnik K (z obliczeń) colour","methodology_en":"Directional luminous intensity Colour K factor (calculated) colour","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Światłość kierunkowa Barwa Współczynnik K (z obliczeń) colour","reference":"PN-EN 13032-1+A1:2012 PN-EN 15153+A1:2016-12 PN-EN 15153-1:2020-06","norm_bases":["PN-EN 13032-1+A1:2012 PN-EN 15153+A1:2016-12 PN-EN 15153-1:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sygnalizator czoła i końca pociągu Światłość kierunkowa Barwa Współczynnik K (z obliczeń) colour PN-EN 13032-1+A1:2012 PN-EN 15153+A1:2016-12 PN-EN 15153-1:2020-06 Sygnalizator czola i konca pociagu Swiatlosc kierunkowa Barwa Wspolczynnik K (z obliczen) colour PN-EN 13032-1+A1:2012 PN-EN 15153+A1:2016-12 PN-EN 15153-1:2020-06","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Train head and tail signal lamp Directional luminous intensity Colour K factor (calculated) colour PN-EN 13032-1+A1:2012 PN-EN 15153+A1:2016-12 PN-EN 15153-1:2020-06"},{"_id":"6a5a55f19af9f73f38250ee7","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Elektryczne przyrządy do użytku domowego i podobnego","test_object_en":"Electrical appliances for household and similar use","methodology":"Ochrona przed dostępem do części czynnych Rozruch przyrządów z napędem silnikowym Pobór mocy i prądu Przyrosty temperatury Przepięcie udarowe Odporność na wilgoć Prąd upływowy i wytrzymałość elektryczna Zabezpieczenie przed przeciążeniem transformatorów i obwodów zasilanych z transformatorów Odporność na zużycie Ochrona przed pożarem i porażeniem prądem elektrycznym w stanie pracy w warunkach nienormalnych Stateczność i ochrona przed zagrożeniami mechanicznymi Wytrzymałość mechaniczna Wymiary i konstrukcja zacisków Wytrzymałość mechaniczna Napięcie prądu elektrycznego Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły – badane cechy wg odnośnych norm przedmiotowych Trwałość połączeń elektrycznych i mechanicznych Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Przyłączenie do zasilania Zaciski przewodów zewnętrznych Wymiary i trwałość mechaniczna połączeń mechanicznych i elektrycznych Odstępy izolacyjne powierzchniowe, powietrzne i skrośne Odporność na wysoką temperaturę, żar i prądy pełzające Odporność na korozję Bezwzględna wartość natężenia napromienienia UV i VIS Skuteczna wartość natężenia napromienienia ważona wg dowolnej charakterystyki czułości w ww. zakresie Pomiar oddziaływania pola elektromagnetycznego","methodology_en":"Protection against access to live parts Starting of motor-operated appliances Power and current input Temperature rise Impulse overvoltage Moisture resistance Leakage current and electric strength Overload protection of transformers and associated circuits Resistance to wear Protection against fire and electric shock under abnormal operation Stability and protection against mechanical hazards Mechanical strength Dimensions and construction of terminals Mechanical strength Electric voltage Type of insulating materials Insulation construction Components – characteristics tested according to the relevant product standards Durability of electrical and mechanical connections Continuity of protective connections Resistance of protective connections Connection to the supply Terminals for external conductors Dimensions and mechanical durability of mechanical and electrical connections Creepage distances, clearances and distances through insulation Resistance to heat, fire and tracking Resistance to corrosion Absolute value of UV and VIS irradiance Effective value of irradiance weighted according to any sensitivity characteristic in the above range Measurement of electromagnetic field exposure","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ochrona przed dostępem do części czynnych Rozruch przyrządów z napędem silnikowym Pobór mocy i prądu Przyrosty temperatury Przepięcie udarowe Odporność na wilgoć Prąd upływowy i wytrzymałość elektryczna Zabezpieczenie przed przeciążeniem transformatorów i obwodów zasilanych z transformatorów Odporność na zużycie Ochrona przed pożarem i porażeniem prądem elektrycznym w stanie pracy w warunkach nienormalnych Stateczność i ochrona przed zagrożeniami mechanicznymi Wytrzymałość mechaniczna Wymiary i konstrukcja zacisków Wytrzymałość mechaniczna Napięcie prądu elektrycznego Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły – badane cechy wg odnośnych norm przedmiotowych Trwałość połączeń elektrycznych i mechanicznych Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Przyłączenie do zasilania Zaciski przewodów zewnętrznych Wymiary i trwałość mechaniczna połączeń mechanicznych i elektrycznych Odstępy izolacyjne powierzchniowe, powietrzne i skrośne Odporność na wysoką temperaturę, żar i prądy pełzające Odporność na korozję Bezwzględna wartość natężenia napromienienia UV i VIS Skuteczna wartość natężenia napromienienia ważona wg dowolnej charakterystyki czułości w ww. zakresie Pomiar oddziaływania pola elektromagnetycznego","reference":"PN-EN IEC 60335-1:2024-04","norm_bases":["PN-EN IEC 60335-1:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne przyrządy do użytku domowego i podobnego Ochrona przed dostępem do części czynnych Rozruch przyrządów z napędem silnikowym Pobór mocy i prądu Przyrosty temperatury Przepięcie udarowe Odporność na wilgoć Prąd upływowy i wytrzymałość elektryczna Zabezpieczenie przed przeciążeniem transformatorów i obwodów zasilanych z transformatorów Odporność na zużycie Ochrona przed pożarem i porażeniem prądem elektrycznym w stanie pracy w warunkach nienormalnych Stateczność i ochrona przed zagrożeniami mechanicznymi Wytrzymałość mechaniczna Wymiary i konstrukcja zacisków Wytrzymałość mechaniczna Napięcie prądu elektrycznego Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły – badane cechy wg odnośnych norm przedmiotowych Trwałość połączeń elektrycznych i mechanicznych Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Przyłączenie do zasilania Zaciski przewodów zewnętrznych Wymiary i trwałość mechaniczna połączeń mechanicznych i elektrycznych Odstępy izolacyjne powierzchniowe, powietrzne i skrośne Odporność na wysoką temperaturę, żar i prądy pełzające Odporność na korozję Bezwzględna wartość natężenia napromienienia UV i VIS Skuteczna wartość natężenia napromienienia ważona wg dowolnej charakterystyki czułości w ww. zakresie Pomiar oddziaływania pola elektromagnetycznego PN-EN IEC 60335-1:2024-04 Elektryczne przyrzady do uzytku domowego i podobnego Ochrona przed dostepem do czesci czynnych Rozruch przyrzadow z napedem silnikowym Pobor mocy i pradu Przyrosty temperatury Przepiecie udarowe Odpornosc na wilgoc Prad uplywowy i wytrzymalosc elektryczna Zabezpieczenie przed przeciazeniem transformatorow i obwodow zasilanych z transformatorow Odpornosc na zuzycie Ochrona przed pozarem i porazeniem pradem elektrycznym w stanie pracy w warunkach nienormalnych Statecznosc i ochrona przed zagrozeniami mechanicznymi Wytrzymalosc mechaniczna Wymiary i konstrukcja zaciskow Wytrzymalosc mechaniczna Napiecie pradu elektrycznego Rodzaj materialow izolacyjnych Konstrukcja izolacji Podzespoly – badane cechy wg odnosnych norm przedmiotowych Trwalosc polaczen elektrycznych i mechanicznych Ciaglosc polaczen ochronnych Rezystancja polaczen ochronnych Przylaczenie do zasilania Zaciski przewodow zewnetrznych Wymiary i trwalosc mechaniczna polaczen mechanicznych i elektrycznych Odstepy izolacyjne powierzchniowe, powietrzne i skrosne Odpornosc na wysoka temperature, zar i prady pelzajace Odpornosc na korozje Bezwzgledna wartosc natezenia napromienienia UV i VIS Skuteczna wartosc natezenia napromienienia wazona wg dowolnej charakterystyki czulosci w ww. zakresie Pomiar oddzialywania pola elektromagnetycznego PN-EN IEC 60335-1:2024-04","categories":["materials","construction"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical appliances for household and similar use Protection against access to live parts Starting of motor-operated appliances Power and current input Temperature rise Impulse overvoltage Moisture resistance Leakage current and electric strength Overload protection of transformers and associated circuits Resistance to wear Protection against fire and electric shock under abnormal operation Stability and protection against mechanical hazards Mechanical strength Dimensions and construction of terminals Mechanical strength Electric voltage Type of insulating materials Insulation construction Components – characteristics tested according to the relevant product standards Durability of electrical and mechanical connections Continuity of protective connections Resistance of protective connections Connection to the supply Terminals for external conductors Dimensions and mechanical durability of mechanical and electrical connections Creepage distances, clearances and distances through insulation Resistance to heat, fire and tracking Resistance to corrosion Absolute value of UV and VIS irradiance Effective value of irradiance weighted according to any sensitivity characteristic in the above range Measurement of electromagnetic field exposure PN-EN IEC 60335-1:2024-04"},{"_id":"6a5a55f19af9f73f38250ee8","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Ochrona przed dostępem do części czynnych Pobór mocy i prądu Przyrosty temperatury Przepięcie udarowe Odporność na wilgoć Prąd upływowy i wytrzymałość elektryczna Zabezpieczenie przed przeciążeniem transformatorów i obwodów zasilanych z transformatorów Odporność na zużycie Ochrona przed pożarem i porażeniem prądem elektrycznym w stanie pracy w warunkach nienormalnych Stateczność i ochrona przed zagrożeniami mechanicznymi. Wytrzymałość mechaniczna Wymiary i konstrukcja zacisków Wytrzymałość mechaniczna Napięcie prądu elektrycznego Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły - badane cechy wg odnośnych norm przedmiotowych Trwałość połączeń elektrycznych i mechanicznych Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Przyłączenie do zasilania Zaciski przewodów zewnętrznych Wymiary i trwałość mechaniczna połączeń mechanicznych i elektrycznych Odstępy izolacyjne powierzchniowe, powietrzne i skrośne Odporność na wysoką temperaturę, żar i prądy pełzające Odporność na korozję Moc promieniowania optycznego Natężenie napromienienia Luminancja energetyczna w zakresie (250÷830) nm Natężenie oświetlenia Luminancja Światłość kierunkowa Ogólny wskaźnik oddawania barw Temperatura barwowa najbliższa","methodology_en":"Protection against access to live parts Power and current input Temperature rise Impulse overvoltage Moisture resistance Leakage current and electric strength Overload protection of transformers and associated circuits Resistance to wear Protection against fire and electric shock under abnormal operation Stability and protection against mechanical hazards. Mechanical strength Dimensions and construction of terminals Mechanical strength Electric voltage Type of insulating materials Insulation construction Components - characteristics tested according to the relevant product standards Durability of electrical and mechanical connections Continuity of protective connections Resistance of protective connections Connection to the supply Terminals for external conductors Dimensions and mechanical durability of mechanical and electrical connections Creepage distances, clearances and distances through insulation Resistance to heat, fire and tracking Resistance to corrosion Optical radiation power Irradiance Radiance in the range (250÷830) nm Illuminance Luminance Directional luminous intensity General colour rendering index Correlated colour temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ochrona przed dostępem do części czynnych Pobór mocy i prądu Przyrosty temperatury Przepięcie udarowe Odporność na wilgoć Prąd upływowy i wytrzymałość elektryczna Zabezpieczenie przed przeciążeniem transformatorów i obwodów zasilanych z transformatorów Odporność na zużycie Ochrona przed pożarem i porażeniem prądem elektrycznym w stanie pracy w warunkach nienormalnych Stateczność i ochrona przed zagrożeniami mechanicznymi. Wytrzymałość mechaniczna Wymiary i konstrukcja zacisków Wytrzymałość mechaniczna Napięcie prądu elektrycznego Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły - badane cechy wg odnośnych norm przedmiotowych Trwałość połączeń elektrycznych i mechanicznych Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Przyłączenie do zasilania Zaciski przewodów zewnętrznych Wymiary i trwałość mechaniczna połączeń mechanicznych i elektrycznych Odstępy izolacyjne powierzchniowe, powietrzne i skrośne Odporność na wysoką temperaturę, żar i prądy pełzające Odporność na korozję Moc promieniowania optycznego Natężenie napromienienia Luminancja energetyczna w zakresie (250÷830) nm Natężenie oświetlenia Luminancja Światłość kierunkowa Ogólny wskaźnik oddawania barw Temperatura barwowa najbliższa","reference":"PN-EN 60601-1:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A2:2022-03 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","norm_bases":["PN-EN 60601-1:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A2:2022-03 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Ochrona przed dostępem do części czynnych Pobór mocy i prądu Przyrosty temperatury Przepięcie udarowe Odporność na wilgoć Prąd upływowy i wytrzymałość elektryczna Zabezpieczenie przed przeciążeniem transformatorów i obwodów zasilanych z transformatorów Odporność na zużycie Ochrona przed pożarem i porażeniem prądem elektrycznym w stanie pracy w warunkach nienormalnych Stateczność i ochrona przed zagrożeniami mechanicznymi. Wytrzymałość mechaniczna Wymiary i konstrukcja zacisków Wytrzymałość mechaniczna Napięcie prądu elektrycznego Rodzaj materiałów izolacyjnych Konstrukcja izolacji Podzespoły - badane cechy wg odnośnych norm przedmiotowych Trwałość połączeń elektrycznych i mechanicznych Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Przyłączenie do zasilania Zaciski przewodów zewnętrznych Wymiary i trwałość mechaniczna połączeń mechanicznych i elektrycznych Odstępy izolacyjne powierzchniowe, powietrzne i skrośne Odporność na wysoką temperaturę, żar i prądy pełzające Odporność na korozję Moc promieniowania optycznego Natężenie napromienienia Luminancja energetyczna w zakresie (250÷830) nm Natężenie oświetlenia Luminancja Światłość kierunkowa Ogólny wskaźnik oddawania barw Temperatura barwowa najbliższa PN-EN 60601-1:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A2:2022-03 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984 Medyczne urzadzenia elektryczne Ochrona przed dostepem do czesci czynnych Pobor mocy i pradu Przyrosty temperatury Przepiecie udarowe Odpornosc na wilgoc Prad uplywowy i wytrzymalosc elektryczna Zabezpieczenie przed przeciazeniem transformatorow i obwodow zasilanych z transformatorow Odpornosc na zuzycie Ochrona przed pozarem i porazeniem pradem elektrycznym w stanie pracy w warunkach nienormalnych Statecznosc i ochrona przed zagrozeniami mechanicznymi. Wytrzymalosc mechaniczna Wymiary i konstrukcja zaciskow Wytrzymalosc mechaniczna Napiecie pradu elektrycznego Rodzaj materialow izolacyjnych Konstrukcja izolacji Podzespoly - badane cechy wg odnosnych norm przedmiotowych Trwalosc polaczen elektrycznych i mechanicznych Ciaglosc polaczen ochronnych Rezystancja polaczen ochronnych Przylaczenie do zasilania Zaciski przewodow zewnetrznych Wymiary i trwalosc mechaniczna polaczen mechanicznych i elektrycznych Odstepy izolacyjne powierzchniowe, powietrzne i skrosne Odpornosc na wysoka temperature, zar i prady pelzajace Odpornosc na korozje Moc promieniowania optycznego Natezenie napromienienia Luminancja energetyczna w zakresie (250÷830) nm Natezenie oswietlenia Luminancja Swiatlosc kierunkowa Ogolny wskaznik oddawania barw Temperatura barwowa najblizsza PN-EN 60601-1:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A2:2022-03 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","categories":["materials","construction"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Protection against access to live parts Power and current input Temperature rise Impulse overvoltage Moisture resistance Leakage current and electric strength Overload protection of transformers and associated circuits Resistance to wear Protection against fire and electric shock under abnormal operation Stability and protection against mechanical hazards. Mechanical strength Dimensions and construction of terminals Mechanical strength Electric voltage Type of insulating materials Insulation construction Components - characteristics tested according to the relevant product standards Durability of electrical and mechanical connections Continuity of protective connections Resistance of protective connections Connection to the supply Terminals for external conductors Dimensions and mechanical durability of mechanical and electrical connections Creepage distances, clearances and distances through insulation Resistance to heat, fire and tracking Resistance to corrosion Optical radiation power Irradiance Radiance in the range (250÷830) nm Illuminance Luminance Directional luminous intensity General colour rendering index Correlated colour temperature PN-EN 60601-1:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A2:2022-03 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","search_zh":"医用电气设备 PN-EN 60601-1:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A2:2022-03 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","test_object_zh":"医用电气设备"},{"_id":"6a5a55f19af9f73f38250ee9","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Żarówki","test_object_en":"Incandescent lamps","methodology":"Wytrzymałość na skręcanie Napięcie, natężenie prądu i moc czynna lampy w warunkach ustalonych Współczynnik utrzymania strumienia świetlnego Przyrost temperatury na trzonku lampy Trwałość cechowania Wymiary żarówek Początkowa moc Początkowy strumień świetlny Stabilność strumienia świetlnego Trwałość Wymiary liniowe lamp Wymiary liniowe trzonków i cokołów Ochrona przed przypadkowym dotykiem Dostęp do części przypadkowo czynnych Moc maksymalna Temperatura spłaszcza, bańki, końcówki stykowej obrzeża Chromatyczność barwy Temperatura barwowa najbliższa Wskaźnik oddawania barw","methodology_en":"Torsional strength Voltage, current and active power of the lamp under steady-state conditions Luminous flux maintenance factor Temperature rise at the lamp cap Durability of marking Dimensions of bulbs Initial power Initial luminous flux Luminous flux stability Durability Linear dimensions of lamps Linear dimensions of caps and bases Protection against accidental contact Access to accidentally live parts Maximum power Temperature of the pinch, bulb, contact end of the rim Colour chromaticity Correlated colour temperature Colour rendering index","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcanie Napięcie, natężenie prądu i moc czynna lampy w warunkach ustalonych Współczynnik utrzymania strumienia świetlnego Przyrost temperatury na trzonku lampy Trwałość cechowania Wymiary żarówek Początkowa moc Początkowy strumień świetlny Stabilność strumienia świetlnego Trwałość Wymiary liniowe lamp Wymiary liniowe trzonków i cokołów Ochrona przed przypadkowym dotykiem Dostęp do części przypadkowo czynnych Moc maksymalna Temperatura spłaszcza, bańki, końcówki stykowej obrzeża Chromatyczność barwy Temperatura barwowa najbliższa Wskaźnik oddawania barw","reference":"PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A5:2010 PN-EN 60064:2002/A11:2008 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","norm_bases":["PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A5:2010 PN-EN 60064:2002/A11:2008 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żarówki Wytrzymałość na skręcanie Napięcie, natężenie prądu i moc czynna lampy w warunkach ustalonych Współczynnik utrzymania strumienia świetlnego Przyrost temperatury na trzonku lampy Trwałość cechowania Wymiary żarówek Początkowa moc Początkowy strumień świetlny Stabilność strumienia świetlnego Trwałość Wymiary liniowe lamp Wymiary liniowe trzonków i cokołów Ochrona przed przypadkowym dotykiem Dostęp do części przypadkowo czynnych Moc maksymalna Temperatura spłaszcza, bańki, końcówki stykowej obrzeża Chromatyczność barwy Temperatura barwowa najbliższa Wskaźnik oddawania barw PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A5:2010 PN-EN 60064:2002/A11:2008 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984 Zarowki Wytrzymalosc na skrecanie Napiecie, natezenie pradu i moc czynna lampy w warunkach ustalonych Wspolczynnik utrzymania strumienia swietlnego Przyrost temperatury na trzonku lampy Trwalosc cechowania Wymiary zarowek Poczatkowa moc Poczatkowy strumien swietlny Stabilnosc strumienia swietlnego Trwalosc Wymiary liniowe lamp Wymiary liniowe trzonkow i cokolow Ochrona przed przypadkowym dotykiem Dostep do czesci przypadkowo czynnych Moc maksymalna Temperatura splaszcza, banki, koncowki stykowej obrzeza Chromatycznosc barwy Temperatura barwowa najblizsza Wskaznik oddawania barw PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A5:2010 PN-EN 60064:2002/A11:2008 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Incandescent lamps Torsional strength Voltage, current and active power of the lamp under steady-state conditions Luminous flux maintenance factor Temperature rise at the lamp cap Durability of marking Dimensions of bulbs Initial power Initial luminous flux Luminous flux stability Durability Linear dimensions of lamps Linear dimensions of caps and bases Protection against accidental contact Access to accidentally live parts Maximum power Temperature of the pinch, bulb, contact end of the rim Colour chromaticity Correlated colour temperature Colour rendering index PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A5:2010 PN-EN 60064:2002/A11:2008 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984"},{"_id":"6a5a55f19af9f73f38250eea","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Żarówki halogenowe","test_object_en":"Halogen lamps","methodology":"Wytrzymałość na skręcanie Napięcie, natężenie prądu i moc czynna lampy w warunkach ustalonych Współczynnik utrzymania strumienia świetlnego Przyrost temperatury na trzonku lampy Trwałość cechowania Wymiary żarówek Początkowa moc Początkowy strumień świetlny Stabilność strumienia świetlnego Trwałość Wymiary liniowe lamp Wymiary liniowe trzonków i cokołów Ochrona przed przypadkowym dotykiem Dostęp do części przypadkowo czynnych Moc maksymalna Temperatura spłaszcza, bańki, końcówki stykowej obrzeża Chromatyczność barwy Temperatura barwowa najbliższa Wskaźnik oddawania barw","methodology_en":"Torsional strength Voltage, current and active power of the lamp under steady-state conditions Luminous flux maintenance factor Temperature rise at the lamp cap Durability of marking Dimensions of bulbs Initial power Initial luminous flux Luminous flux stability Durability Linear dimensions of lamps Linear dimensions of caps and bases Protection against accidental contact Access to accidentally live parts Maximum power Temperature of the pinch, bulb, contact end of the rim Colour chromaticity Correlated colour temperature Colour rendering index","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcanie Napięcie, natężenie prądu i moc czynna lampy w warunkach ustalonych Współczynnik utrzymania strumienia świetlnego Przyrost temperatury na trzonku lampy Trwałość cechowania Wymiary żarówek Początkowa moc Początkowy strumień świetlny Stabilność strumienia świetlnego Trwałość Wymiary liniowe lamp Wymiary liniowe trzonków i cokołów Ochrona przed przypadkowym dotykiem Dostęp do części przypadkowo czynnych Moc maksymalna Temperatura spłaszcza, bańki, końcówki stykowej obrzeża Chromatyczność barwy Temperatura barwowa najbliższa Wskaźnik oddawania barw","reference":"PN-EN 60357:2003 PN-EN 60357:2003/A1:2008 PN-EN 60357:2003/A2:2009 PN-EN 60357:2003/A3:2011 PN-EN 60357:2003/A11:2016-12 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:20 Publikacja CIE 084:1989 Publikacja CIE 63:1984","norm_bases":["PN-EN 60357:2003 PN-EN 60357:2003/A1:2008 PN-EN 60357:2003/A2:2009 PN-EN 60357:2003/A3:2011 PN-EN 60357:2003/A11:2016-12 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:20 Publikacja CIE 084:1989 Publikacja CIE 63:1984"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żarówki halogenowe Wytrzymałość na skręcanie Napięcie, natężenie prądu i moc czynna lampy w warunkach ustalonych Współczynnik utrzymania strumienia świetlnego Przyrost temperatury na trzonku lampy Trwałość cechowania Wymiary żarówek Początkowa moc Początkowy strumień świetlny Stabilność strumienia świetlnego Trwałość Wymiary liniowe lamp Wymiary liniowe trzonków i cokołów Ochrona przed przypadkowym dotykiem Dostęp do części przypadkowo czynnych Moc maksymalna Temperatura spłaszcza, bańki, końcówki stykowej obrzeża Chromatyczność barwy Temperatura barwowa najbliższa Wskaźnik oddawania barw PN-EN 60357:2003 PN-EN 60357:2003/A1:2008 PN-EN 60357:2003/A2:2009 PN-EN 60357:2003/A3:2011 PN-EN 60357:2003/A11:2016-12 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:20 Publikacja CIE 084:1989 Publikacja CIE 63:1984 Zarowki halogenowe Wytrzymalosc na skrecanie Napiecie, natezenie pradu i moc czynna lampy w warunkach ustalonych Wspolczynnik utrzymania strumienia swietlnego Przyrost temperatury na trzonku lampy Trwalosc cechowania Wymiary zarowek Poczatkowa moc Poczatkowy strumien swietlny Stabilnosc strumienia swietlnego Trwalosc Wymiary liniowe lamp Wymiary liniowe trzonkow i cokolow Ochrona przed przypadkowym dotykiem Dostep do czesci przypadkowo czynnych Moc maksymalna Temperatura splaszcza, banki, koncowki stykowej obrzeza Chromatycznosc barwy Temperatura barwowa najblizsza Wskaznik oddawania barw PN-EN 60357:2003 PN-EN 60357:2003/A1:2008 PN-EN 60357:2003/A2:2009 PN-EN 60357:2003/A3:2011 PN-EN 60357:2003/A11:2016-12 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:20 Publikacja CIE 084:1989 Publikacja CIE 63:1984","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Halogen lamps Torsional strength Voltage, current and active power of the lamp under steady-state conditions Luminous flux maintenance factor Temperature rise at the lamp cap Durability of marking Dimensions of bulbs Initial power Initial luminous flux Luminous flux stability Durability Linear dimensions of lamps Linear dimensions of caps and bases Protection against accidental contact Access to accidentally live parts Maximum power Temperature of the pinch, bulb, contact end of the rim Colour chromaticity Correlated colour temperature Colour rendering index PN-EN 60357:2003 PN-EN 60357:2003/A1:2008 PN-EN 60357:2003/A2:2009 PN-EN 60357:2003/A3:2011 PN-EN 60357:2003/A11:2016-12 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:20 Publikacja CIE 084:1989 Publikacja CIE 63:1984"},{"_id":"6a5a55f19af9f73f38250eeb","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Lampy sodowe","test_object_en":"Sodium vapour lamps","methodology":"Trwałość znakowania lampy Wymiary lampy Wymiary liniowe trzonków Ochrona przed przypadkowym dotykiem Dostęp do części przypadkowo czynnych Szczytowa wartość napięcia impulsu zapłonowego Napięcie, natężenie prądu i moc czynna lampy w warunkach ustalonych Strumień świetlny Natężenie prądu podgrzewającego Współczynnik kształtu prądu Przyrost temperatury trzonka Odporność na efekt prostownikowy Chromatyczność barwy Wskaźnik oddawania barw Temperatura barwowa najbliższa","methodology_en":"Durability of lamp marking Lamp dimensions Linear dimensions of caps Protection against accidental contact Access to accidentally live parts Peak value of the starting pulse voltage Lamp voltage, current and active power under stabilized conditions Luminous flux Preheating current Current crest factor Cap temperature rise Resistance to the rectifying effect Chromaticity Colour rendering index Correlated colour temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania lampy Wymiary lampy Wymiary liniowe trzonków Ochrona przed przypadkowym dotykiem Dostęp do części przypadkowo czynnych Szczytowa wartość napięcia impulsu zapłonowego Napięcie, natężenie prądu i moc czynna lampy w warunkach ustalonych Strumień świetlny Natężenie prądu podgrzewającego Współczynnik kształtu prądu Przyrost temperatury trzonka Odporność na efekt prostownikowy Chromatyczność barwy Wskaźnik oddawania barw Temperatura barwowa najbliższa","reference":"PN-EN 60662:2012 PN-EN 60662:2012 /A11:2019-11 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","norm_bases":["PN-EN 60662:2012 PN-EN 60662:2012 /A11:2019-11 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lampy sodowe Trwałość znakowania lampy Wymiary lampy Wymiary liniowe trzonków Ochrona przed przypadkowym dotykiem Dostęp do części przypadkowo czynnych Szczytowa wartość napięcia impulsu zapłonowego Napięcie, natężenie prądu i moc czynna lampy w warunkach ustalonych Strumień świetlny Natężenie prądu podgrzewającego Współczynnik kształtu prądu Przyrost temperatury trzonka Odporność na efekt prostownikowy Chromatyczność barwy Wskaźnik oddawania barw Temperatura barwowa najbliższa PN-EN 60662:2012 PN-EN 60662:2012 /A11:2019-11 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984 Lampy sodowe Trwalosc znakowania lampy Wymiary lampy Wymiary liniowe trzonkow Ochrona przed przypadkowym dotykiem Dostep do czesci przypadkowo czynnych Szczytowa wartosc napiecia impulsu zaplonowego Napiecie, natezenie pradu i moc czynna lampy w warunkach ustalonych Strumien swietlny Natezenie pradu podgrzewajacego Wspolczynnik ksztaltu pradu Przyrost temperatury trzonka Odpornosc na efekt prostownikowy Chromatycznosc barwy Wskaznik oddawania barw Temperatura barwowa najblizsza PN-EN 60662:2012 PN-EN 60662:2012 /A11:2019-11 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sodium vapour lamps Durability of lamp marking Lamp dimensions Linear dimensions of caps Protection against accidental contact Access to accidentally live parts Peak value of the starting pulse voltage Lamp voltage, current and active power under stabilized conditions Luminous flux Preheating current Current crest factor Cap temperature rise Resistance to the rectifying effect Chromaticity Colour rendering index Correlated colour temperature PN-EN 60662:2012 PN-EN 60662:2012 /A11:2019-11 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984"},{"_id":"6a5a55f19af9f73f38250eec","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Świetlówki dwutrzonkowe","test_object_en":"Double-capped fluorescent lamps","methodology":"Wymiary liniowe trzonków Wymiary liniowe lamp Napięcie, natężenie prądu i moc czynna lampy i rezystancja katod w warunkach ustalonych Strumień świetlny Chromatyczność barwy Wskaźnik oddawania barw Temperatura barwowa najbliższa Współczynnik utrzymania strumienia świetlnego Trwałość cechowania Przyrost temperatury na trzonku lampy Tłumienie zakłóceń radiowych","methodology_en":"Linear dimensions of caps Linear dimensions of lamps Voltage, current and active power of the lamp and cathode resistance under stabilised conditions Luminous flux Colour chromaticity Colour rendering index Correlated colour temperature Luminous flux maintenance factor Durability of marking Temperature rise at the lamp cap Radio interference suppression","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe trzonków Wymiary liniowe lamp Napięcie, natężenie prądu i moc czynna lampy i rezystancja katod w warunkach ustalonych Strumień świetlny Chromatyczność barwy Wskaźnik oddawania barw Temperatura barwowa najbliższa Współczynnik utrzymania strumienia świetlnego Trwałość cechowania Przyrost temperatury na trzonku lampy Tłumienie zakłóceń radiowych","reference":"PN-EN 60081:2002 PN-EN 60081:2002/A2:2005 PN-EN 60081:2002/A3:2006 PN-EN 60081:2002/A4:2010 PN-EN 60081:2002/A5:2014-02 PN-EN 60081:2002/A6:2018-02 PN-EN 60081:2002/A11:2018-10 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","norm_bases":["PN-EN 60081:2002 PN-EN 60081:2002/A2:2005 PN-EN 60081:2002/A3:2006 PN-EN 60081:2002/A4:2010 PN-EN 60081:2002/A5:2014-02 PN-EN 60081:2002/A6:2018-02 PN-EN 60081:2002/A11:2018-10 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetlówki dwutrzonkowe Wymiary liniowe trzonków Wymiary liniowe lamp Napięcie, natężenie prądu i moc czynna lampy i rezystancja katod w warunkach ustalonych Strumień świetlny Chromatyczność barwy Wskaźnik oddawania barw Temperatura barwowa najbliższa Współczynnik utrzymania strumienia świetlnego Trwałość cechowania Przyrost temperatury na trzonku lampy Tłumienie zakłóceń radiowych PN-EN 60081:2002 PN-EN 60081:2002/A2:2005 PN-EN 60081:2002/A3:2006 PN-EN 60081:2002/A4:2010 PN-EN 60081:2002/A5:2014-02 PN-EN 60081:2002/A6:2018-02 PN-EN 60081:2002/A11:2018-10 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984 Swietlowki dwutrzonkowe Wymiary liniowe trzonkow Wymiary liniowe lamp Napiecie, natezenie pradu i moc czynna lampy i rezystancja katod w warunkach ustalonych Strumien swietlny Chromatycznosc barwy Wskaznik oddawania barw Temperatura barwowa najblizsza Wspolczynnik utrzymania strumienia swietlnego Trwalosc cechowania Przyrost temperatury na trzonku lampy Tlumienie zaklocen radiowych PN-EN 60081:2002 PN-EN 60081:2002/A2:2005 PN-EN 60081:2002/A3:2006 PN-EN 60081:2002/A4:2010 PN-EN 60081:2002/A5:2014-02 PN-EN 60081:2002/A6:2018-02 PN-EN 60081:2002/A11:2018-10 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Double-capped fluorescent lamps Linear dimensions of caps Linear dimensions of lamps Voltage, current and active power of the lamp and cathode resistance under stabilised conditions Luminous flux Colour chromaticity Colour rendering index Correlated colour temperature Luminous flux maintenance factor Durability of marking Temperature rise at the lamp cap Radio interference suppression PN-EN 60081:2002 PN-EN 60081:2002/A2:2005 PN-EN 60081:2002/A3:2006 PN-EN 60081:2002/A4:2010 PN-EN 60081:2002/A5:2014-02 PN-EN 60081:2002/A6:2018-02 PN-EN 60081:2002/A11:2018-10 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Publikacja CIE 63:1984"},{"_id":"6a5a55f19af9f73f38250eed","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Urządzenia do lamp","test_object_en":"Equipment for lamps","methodology":"Trwałość znakowania Napięcie i prąd wyjściowy Moc pobierana Współczynnik mocy Prąd zasilający Prąd lampy i strumień świetlny Działanie w warunkach nienormalnych Charakterystyki funkcjonalne Tłumienie zakłóceń radiowych Zabezpieczenie przed wpływami magnetycznymi Trwałość","methodology_en":"Durability of marking Output voltage and current Power consumption Power factor Supply current Lamp current and luminous flux Operation under abnormal conditions Functional characteristics Radio interference suppression Protection against magnetic influences Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania Napięcie i prąd wyjściowy Moc pobierana Współczynnik mocy Prąd zasilający Prąd lampy i strumień świetlny Działanie w warunkach nienormalnych Charakterystyki funkcjonalne Tłumienie zakłóceń radiowych Zabezpieczenie przed wpływami magnetycznymi Trwałość","reference":"PN-EN 60921:2005 PN-EN 60921:2005/A1:2006 PN-EN 60923:2006 PN-EN 60923:2006/A1:2006 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60927:2007 PN-EN 60927:2007/A1:2014-04 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 61047:2005 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989","norm_bases":["PN-EN 60921:2005 PN-EN 60921:2005/A1:2006 PN-EN 60923:2006 PN-EN 60923:2006/A1:2006 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60927:2007 PN-EN 60927:2007/A1:2014-04 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 61047:2005 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia do lamp Trwałość znakowania Napięcie i prąd wyjściowy Moc pobierana Współczynnik mocy Prąd zasilający Prąd lampy i strumień świetlny Działanie w warunkach nienormalnych Charakterystyki funkcjonalne Tłumienie zakłóceń radiowych Zabezpieczenie przed wpływami magnetycznymi Trwałość PN-EN 60921:2005 PN-EN 60921:2005/A1:2006 PN-EN 60923:2006 PN-EN 60923:2006/A1:2006 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60927:2007 PN-EN 60927:2007/A1:2014-04 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 61047:2005 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Urzadzenia do lamp Trwalosc znakowania Napiecie i prad wyjsciowy Moc pobierana Wspolczynnik mocy Prad zasilajacy Prad lampy i strumien swietlny Dzialanie w warunkach nienormalnych Charakterystyki funkcjonalne Tlumienie zaklocen radiowych Zabezpieczenie przed wplywami magnetycznymi Trwalosc PN-EN 60921:2005 PN-EN 60921:2005/A1:2006 PN-EN 60923:2006 PN-EN 60923:2006/A1:2006 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60927:2007 PN-EN 60927:2007/A1:2014-04 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 61047:2005 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Equipment for lamps Durability of marking Output voltage and current Power consumption Power factor Supply current Lamp current and luminous flux Operation under abnormal conditions Functional characteristics Radio interference suppression Protection against magnetic influences Durability PN-EN 60921:2005 PN-EN 60921:2005/A1:2006 PN-EN 60923:2006 PN-EN 60923:2006/A1:2006 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60927:2007 PN-EN 60927:2007/A1:2014-04 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 61047:2005 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989"},{"_id":"6a5a55f19af9f73f38250eee","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Oprawy oświetleniowe i źródła światła o maksymalnym wymiarze liniowym powierzchni świecącej 1.2 m oraz maksymalnym poborze prądu do 20 A i ciężarze do 30 kG.","test_object_en":"Luminaires and light sources with a maximum linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG.","methodology":"Rozsył światłości","methodology_en":"Luminous intensity distribution","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rozsył światłości","reference":"PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN IEC 60598-2-22:2022-11 PN-EN 60079-35-2:2012 PN-EN 12966+A1:2019-02","norm_bases":["PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN IEC 60598-2-22:2022-11 PN-EN 60079-35-2:2012 PN-EN 12966+A1:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Oprawy oświetleniowe i źródła światła o maksymalnym wymiarze liniowym powierzchni świecącej 1.2 m oraz maksymalnym poborze prądu do 20 A i ciężarze do 30 kG. Rozsył światłości PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN IEC 60598-2-22:2022-11 PN-EN 60079-35-2:2012 PN-EN 12966+A1:2019-02 Oprawy oswietleniowe i zrodla swiatla o maksymalnym wymiarze liniowym powierzchni swiecacej 1.2 m oraz maksymalnym poborze pradu do 20 A i ciezarze do 30 kG. Rozsyl swiatlosci PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN IEC 60598-2-22:2022-11 PN-EN 60079-35-2:2012 PN-EN 12966+A1:2019-02","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Luminaires and light sources with a maximum linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG. Luminous intensity distribution PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN IEC 60598-2-22:2022-11 PN-EN 60079-35-2:2012 PN-EN 12966+A1:2019-02"},{"_id":"6a5a55f19af9f73f38250eef","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Oprawy oświetleniowe o maksymalnym wymiarze liniowym powierzchni świecącej 1.2 m oraz maksymalnym poborze prądu do 20 A i ciężarze do 30 kG.","test_object_en":"Luminaires with a maximum linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG.","methodology":"Sprawność świetlna","methodology_en":"Luminous efficacy","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawność świetlna","reference":"PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04","norm_bases":["PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Oprawy oświetleniowe o maksymalnym wymiarze liniowym powierzchni świecącej 1.2 m oraz maksymalnym poborze prądu do 20 A i ciężarze do 30 kG. Sprawność świetlna PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 Oprawy oswietleniowe o maksymalnym wymiarze liniowym powierzchni swiecacej 1.2 m oraz maksymalnym poborze pradu do 20 A i ciezarze do 30 kG. Sprawnosc swietlna PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Luminaires with a maximum linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG. Luminous efficacy PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04"},{"_id":"6a5a55f19af9f73f38250ef0","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Oprawy oświetlenia miejscowego","test_object_en":"Local lighting luminaires","methodology":"Natężenie oświetlenia (0÷500) klx","methodology_en":"Illuminance (0÷500) klx","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia (0÷500) klx","reference":"PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN 60079-35-2:2012","norm_bases":["PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN 60079-35-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Oprawy oświetlenia miejscowego Natężenie oświetlenia (0÷500) klx PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN 60079-35-2:2012 Oprawy oswietlenia miejscowego Natezenie oswietlenia (0÷500) klx PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN 60079-35-2:2012","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Local lighting luminaires Illuminance (0÷500) klx PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 PN-EN 60079-35-2:2012"},{"_id":"6a5a55f19af9f73f38250ef1","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Awaryjne oprawy oświetleniowe","test_object_en":"Emergency luminaires","methodology":"Luminancja (0÷999900) cd/m2","methodology_en":"Luminance (0÷999900) cd/m2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Luminancja (0÷999900) cd/m2","reference":"PN-EN IEC 60598-2-22:2022-11","norm_bases":["PN-EN IEC 60598-2-22:2022-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Awaryjne oprawy oświetleniowe Luminancja (0÷999900) cd/m2 PN-EN IEC 60598-2-22:2022-11 Awaryjne oprawy oswietleniowe Luminancja (0÷999900) cd/m2 PN-EN IEC 60598-2-22:2022-11","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Emergency luminaires Luminance (0÷999900) cd/m2 PN-EN IEC 60598-2-22:2022-11"},{"_id":"6a5a55f19af9f73f38250ef2","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Pomieszczenia i ciągi komunikacyjne budynków","test_object_en":"Rooms and circulation routes of buildings","methodology":"Równomierność oświetlenia","methodology_en":"Illuminance uniformity","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia","reference":"PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05","norm_bases":["PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia i ciągi komunikacyjne budynków Równomierność oświetlenia PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05 Pomieszczenia i ciagi komunikacyjne budynkow Rownomiernosc oswietlenia PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms and circulation routes of buildings Illuminance uniformity PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05","methodology_zh":"照度均匀度","search_zh":"照度均匀度 PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05"},{"_id":"6a5a55f19af9f73f38250ef3","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Pomieszczenia i ciągi komunikacyjne budynków","test_object_en":"Rooms and circulation routes of buildings","methodology":"Chromatyczność (0÷1)","methodology_en":"Chromaticity (0÷1)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chromatyczność (0÷1)","reference":"PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05 Publikacja CIE 15:2004","norm_bases":["PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05 Publikacja CIE 15:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia i ciągi komunikacyjne budynków Chromatyczność (0÷1) PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05 Publikacja CIE 15:2004 Pomieszczenia i ciagi komunikacyjne budynkow Chromatycznosc (0÷1) PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05 Publikacja CIE 15:2004","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms and circulation routes of buildings Chromaticity (0÷1) PN-EN 1837:2021-05 PN-EN 1838:2013-11 PN-EN 12464-1:2022-01 PN-EN 12464-2:2014-05 Publikacja CIE 15:2004"},{"_id":"6a5a55f19af9f73f38250ef4","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Powierzchnie świecące, źródła światła","test_object_en":"Luminous surfaces, light sources","methodology":"Chromatyczność (0÷1)","methodology_en":"Chromaticity (0÷1)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chromatyczność (0÷1)","reference":"PN-EN 12966+A1:2019-02 Publikacja CIE 15:2004","norm_bases":["PN-EN 12966+A1:2019-02 Publikacja CIE 15:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powierzchnie świecące, źródła światła Chromatyczność (0÷1) PN-EN 12966+A1:2019-02 Publikacja CIE 15:2004 Powierzchnie swiecace, zrodla swiatla Chromatycznosc (0÷1) PN-EN 12966+A1:2019-02 Publikacja CIE 15:2004","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Luminous surfaces, light sources Chromaticity (0÷1) PN-EN 12966+A1:2019-02 Publikacja CIE 15:2004"},{"_id":"6a5a55f19af9f73f38250ef5","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Oprawy oświetleniowe o maks. wymiarze liniowym powierzchni świecącej 1.2 m oraz maksymalnym poborze prądu do 20 A i ciężarze do 30 kG.","test_object_en":"Luminaires with a max. linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG.","methodology":"Luminancja gabarytowa (0÷999900) cd/m2","methodology_en":"Overall luminance (0÷999900) cd/m2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Luminancja gabarytowa (0÷999900) cd/m2","reference":"PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04","norm_bases":["PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Oprawy oświetleniowe o maks. wymiarze liniowym powierzchni świecącej 1.2 m oraz maksymalnym poborze prądu do 20 A i ciężarze do 30 kG. Luminancja gabarytowa (0÷999900) cd/m2 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04 Oprawy oswietleniowe o maks. wymiarze liniowym powierzchni swiecacej 1.2 m oraz maksymalnym poborze pradu do 20 A i ciezarze do 30 kG. Luminancja gabarytowa (0÷999900) cd/m2 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Luminaires with a max. linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG. Overall luminance (0÷999900) cd/m2 PN-EN 13032-1+A1:2012 PN-EN 13032-2:2018-02 PN-EN 13032-3:2022-04"},{"_id":"6a5a55f19af9f73f38250ef6","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Oprawy oświetleniowe","test_object_en":"Luminaires","methodology":"Geometryczny kąt ochrony C0÷C360° Y0÷90°","methodology_en":"Geometric shielding angle C0÷C360° Y0÷90°","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Geometryczny kąt ochrony C0÷C360° Y0÷90°","reference":"PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12","norm_bases":["PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Oprawy oświetleniowe Geometryczny kąt ochrony C0÷C360° Y0÷90° PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12 Oprawy oswietleniowe Geometryczny kat ochrony C0÷C360° Y0÷90° PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Luminaires Geometric shielding angle C0÷C360° Y0÷90° PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12","search_zh":"灯具 PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021- 07/A11:2022-12","test_object_zh":"灯具"},{"_id":"6a5a55f19af9f73f38250ef7","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Oprawy oświetleniowe sygnalizacyjne, awaryjne i urządzenia specjalne oraz ich elementy optyczne; źródła światła zasilane prądem stałym max 20 A i napięciem max. 100 V lub zasilane prądem zmiennym max. do 20 A.","test_object_en":"Signalling and emergency luminaires and special devices and their optical elements; light sources supplied with direct current of max. 20 A and voltage of max. 100 V or supplied with alternating current of max. 20 A.","methodology":"Parametry spektralne w zakresie VIS i UV (200÷800) nm","methodology_en":"Spectral parameters in the VIS and UV range (200÷800) nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametry spektralne w zakresie VIS i UV (200÷800) nm","reference":"PN-EN 60335-2-27:2014-02 PN-EN 60335-2-59:2007 PN-EN 60335-2-59:2007/A2:2010 PN-EN 60335-2-59:2007/A11:2018- 12 PN-EN IEC 60598-2-22:2022-11","norm_bases":["PN-EN 60335-2-27:2014-02 PN-EN 60335-2-59:2007 PN-EN 60335-2-59:2007/A2:2010 PN-EN 60335-2-59:2007/A11:2018- 12 PN-EN IEC 60598-2-22:2022-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Oprawy oświetleniowe sygnalizacyjne, awaryjne i urządzenia specjalne oraz ich elementy optyczne; źródła światła zasilane prądem stałym max 20 A i napięciem max. 100 V lub zasilane prądem zmiennym max. do 20 A. Parametry spektralne w zakresie VIS i UV (200÷800) nm PN-EN 60335-2-27:2014-02 PN-EN 60335-2-59:2007 PN-EN 60335-2-59:2007/A2:2010 PN-EN 60335-2-59:2007/A11:2018- 12 PN-EN IEC 60598-2-22:2022-11 Oprawy oswietleniowe sygnalizacyjne, awaryjne i urzadzenia specjalne oraz ich elementy optyczne; zrodla swiatla zasilane pradem stalym max 20 A i napieciem max. 100 V lub zasilane pradem zmiennym max. do 20 A. Parametry spektralne w zakresie VIS i UV (200÷800) nm PN-EN 60335-2-27:2014-02 PN-EN 60335-2-59:2007 PN-EN 60335-2-59:2007/A2:2010 PN-EN 60335-2-59:2007/A11:2018- 12 PN-EN IEC 60598-2-22:2022-11","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Signalling and emergency luminaires and special devices and their optical elements; light sources supplied with direct current of max. 20 A and voltage of max. 100 V or supplied with alternating current of max. 20 A. Spectral parameters in the VIS and UV range (200÷800) nm PN-EN 60335-2-27:2014-02 PN-EN 60335-2-59:2007 PN-EN 60335-2-59:2007/A2:2010 PN-EN 60335-2-59:2007/A11:2018- 12 PN-EN IEC 60598-2-22:2022-11"},{"_id":"6a5a55f19af9f73f38250ef8","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Źródła światła żarowe i wyładowcze o strumieniu świetlnym od 10 lm do 500000 lm i mocy do 5 kW, zasilane napięciem stałym lub zmiennym, prądzie do 20 A i maksymalnym wymiarze liniowym do 2 m.","test_object_en":"Incandescent and discharge light sources with a luminous flux from 10 lm to 500000 lm and a power up to 5 kW, supplied with direct or alternating voltage, with a current up to 20 A and a maximum linear dimension up to 2 m.","methodology":"Strumień świetlny (0÷50000) lm","methodology_en":"Luminous flux (0÷50000) lm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień świetlny (0÷50000) lm","reference":"PN-EN 60901:2002 PN-EN 60901:2002/A3:2005 PN-EN 60901:2002/A4:2008 PN-EN 60901:2002/A5:2012 PN-EN 60901:2002/A6:2018-02 PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A11:2008 PN-EN 60064:2002/A5:2010 PN-EN 60969:2002 PN-EN 60188:2004 PN-EN 60188:2004/A11:2019-09","norm_bases":["PN-EN 60901:2002 PN-EN 60901:2002/A3:2005 PN-EN 60901:2002/A4:2008 PN-EN 60901:2002/A5:2012 PN-EN 60901:2002/A6:2018-02 PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A11:2008 PN-EN 60064:2002/A5:2010 PN-EN 60969:2002 PN-EN 60188:2004 PN-EN 60188:2004/A11:2019-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Źródła światła żarowe i wyładowcze o strumieniu świetlnym od 10 lm do 500000 lm i mocy do 5 kW, zasilane napięciem stałym lub zmiennym, prądzie do 20 A i maksymalnym wymiarze liniowym do 2 m. Strumień świetlny (0÷50000) lm PN-EN 60901:2002 PN-EN 60901:2002/A3:2005 PN-EN 60901:2002/A4:2008 PN-EN 60901:2002/A5:2012 PN-EN 60901:2002/A6:2018-02 PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A11:2008 PN-EN 60064:2002/A5:2010 PN-EN 60969:2002 PN-EN 60188:2004 PN-EN 60188:2004/A11:2019-09 Zrodla swiatla zarowe i wyladowcze o strumieniu swietlnym od 10 lm do 500000 lm i mocy do 5 kW, zasilane napieciem stalym lub zmiennym, pradzie do 20 A i maksymalnym wymiarze liniowym do 2 m. Strumien swietlny (0÷50000) lm PN-EN 60901:2002 PN-EN 60901:2002/A3:2005 PN-EN 60901:2002/A4:2008 PN-EN 60901:2002/A5:2012 PN-EN 60901:2002/A6:2018-02 PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A11:2008 PN-EN 60064:2002/A5:2010 PN-EN 60969:2002 PN-EN 60188:2004 PN-EN 60188:2004/A11:2019-09","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Incandescent and discharge light sources with a luminous flux from 10 lm to 500000 lm and a power up to 5 kW, supplied with direct or alternating voltage, with a current up to 20 A and a maximum linear dimension up to 2 m. Luminous flux (0÷50000) lm PN-EN 60901:2002 PN-EN 60901:2002/A3:2005 PN-EN 60901:2002/A4:2008 PN-EN 60901:2002/A5:2012 PN-EN 60901:2002/A6:2018-02 PN-EN 60064:2002 PN-EN 60064:2002/A2:2003 PN-EN 60064:2002/A3:2006 PN-EN 60064:2002/A4:2007 PN-EN 60064:2002/A11:2008 PN-EN 60064:2002/A5:2010 PN-EN 60969:2002 PN-EN 60188:2004 PN-EN 60188:2004/A11:2019-09"},{"_id":"6a5a55f19af9f73f38250ef9","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Awaryjne oprawy oświetleniowe","test_object_en":"Emergency luminaires","methodology":"Strumień świetlny (0÷50000) lm","methodology_en":"Luminous flux (0÷50000) lm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień świetlny (0÷50000) lm","reference":"PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 Publikacja CIE 084:1989","norm_bases":["PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 Publikacja CIE 084:1989"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Awaryjne oprawy oświetleniowe Strumień świetlny (0÷50000) lm PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 Publikacja CIE 084:1989 Awaryjne oprawy oswietleniowe Strumien swietlny (0÷50000) lm PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 Publikacja CIE 084:1989","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Emergency luminaires Luminous flux (0÷50000) lm PN-EN IEC 60598-2-22:2022-11 PN-EN 13032-1+A1:2012 Publikacja CIE 084:1989"},{"_id":"6a5a55f19af9f73f38250efa","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Żarówki projekcyjne i specjalne, świetlówki proste do 40 W o światłości od 1cd do 50000 cd zasilane napięciem stałym lub zmiennym, o prądzie nie przekraczającym 20 A.","test_object_en":"Projection and special lamps, linear fluorescent lamps up to 40 W with a luminous intensity from 1cd to 50000 cd supplied with direct or alternating voltage, with a current not exceeding 20 A.","methodology":"Światłość kierunkowa (0÷500000) cd","methodology_en":"Directional luminous intensity (0÷500000) cd","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Światłość kierunkowa (0÷500000) cd","reference":"PN-EN 12966+A1:2019-02 PN-EN 13032-1+A1:2012","norm_bases":["PN-EN 12966+A1:2019-02 PN-EN 13032-1+A1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żarówki projekcyjne i specjalne, świetlówki proste do 40 W o światłości od 1cd do 50000 cd zasilane napięciem stałym lub zmiennym, o prądzie nie przekraczającym 20 A. Światłość kierunkowa (0÷500000) cd PN-EN 12966+A1:2019-02 PN-EN 13032-1+A1:2012 Zarowki projekcyjne i specjalne, swietlowki proste do 40 W o swiatlosci od 1cd do 50000 cd zasilane napieciem stalym lub zmiennym, o pradzie nie przekraczajacym 20 A. Swiatlosc kierunkowa (0÷500000) cd PN-EN 12966+A1:2019-02 PN-EN 13032-1+A1:2012","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Projection and special lamps, linear fluorescent lamps up to 40 W with a luminous intensity from 1cd to 50000 cd supplied with direct or alternating voltage, with a current not exceeding 20 A. Directional luminous intensity (0÷500000) cd PN-EN 12966+A1:2019-02 PN-EN 13032-1+A1:2012"},{"_id":"6a5a55f19af9f73f38250efb","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Stateczniki elektroniczne DC i AC","test_object_en":"DC and AC electronic ballasts","methodology":"Statecznikowy wskaźnik strumienia","methodology_en":"Ballast lumen factor","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Statecznikowy wskaźnik strumienia","reference":"PN-EN 61347-2-7:2012 PN-EN 61347-2-7:2012 /A1:2019-11 PN-EN 61347-2-7:2012/A2:2022-11 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989","norm_bases":["PN-EN 61347-2-7:2012 PN-EN 61347-2-7:2012 /A1:2019-11 PN-EN 61347-2-7:2012/A2:2022-11 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stateczniki elektroniczne DC i AC Statecznikowy wskaźnik strumienia PN-EN 61347-2-7:2012 PN-EN 61347-2-7:2012 /A1:2019-11 PN-EN 61347-2-7:2012/A2:2022-11 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989 Stateczniki elektroniczne DC i AC Statecznikowy wskaznik strumienia PN-EN 61347-2-7:2012 PN-EN 61347-2-7:2012 /A1:2019-11 PN-EN 61347-2-7:2012/A2:2022-11 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989","categories":["electronics"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"DC and AC electronic ballasts Ballast lumen factor PN-EN 61347-2-7:2012 PN-EN 61347-2-7:2012 /A1:2019-11 PN-EN 61347-2-7:2012/A2:2022-11 PN-EN 61347-2-3:2011 PN-EN 61347-2-3:2011/A1:2017-07 PN-EN 60929:2011 PN-EN 60929:2011/A1:2016-05 PN-EN 13032-1+A1:2012 Publikacja CIE 13.3:1995 Publikacja CIE 15:2004 Publikacja CIE 084:1989"},{"_id":"6a5a55f19af9f73f38250efc","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia","test_object_en":"Low-voltage electrical machines and equipment","methodology":"Poziom mocy akustycznej na podstawie pomiarów poziomu ciśnienia akustycznego Zakres: (16,5÷100) dB Metoda pomiarowa bezpośrednia","methodology_en":"Sound power level based on sound pressure level measurements Range: (16,5÷100) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom mocy akustycznej na podstawie pomiarów poziomu ciśnienia akustycznego Zakres: (16,5÷100) dB Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 1680:2014-02 PN-EN ISO 3744:2011 z wyłączeniem | PN-EN ISO 3743-1:2011 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/AP1:2017-09 PN-EN ISO 3747:2011 PN-EN 62271-202:2014-12 PN-EN 62271-202:2014 -12/ AC1:2015-07 PN-EN 60076-10:2017-01 IEC 60076-10:2016","norm_bases":["PN-EN ISO 1680:2014-02 PN-EN ISO 3744:2011 z wyłączeniem","PN-EN ISO 3743-1:2011 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/AP1:2017-09 PN-EN ISO 3747:2011 PN-EN 62271-202:2014-12 PN-EN 62271-202:2014 -12/ AC1:2015-07 PN-EN 60076-10:2017-01 IEC 60076-10:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia Poziom mocy akustycznej na podstawie pomiarów poziomu ciśnienia akustycznego Zakres: (16,5÷100) dB Metoda pomiarowa bezpośrednia PN-EN ISO 1680:2014-02 PN-EN ISO 3744:2011 z wyłączeniem | PN-EN ISO 3743-1:2011 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/AP1:2017-09 PN-EN ISO 3747:2011 PN-EN 62271-202:2014-12 PN-EN 62271-202:2014 -12/ AC1:2015-07 PN-EN 60076-10:2017-01 IEC 60076-10:2016 Maszyny i urzadzenia elektryczne niskiego napiecia Poziom mocy akustycznej na podstawie pomiarow poziomu cisnienia akustycznego Zakres: (16,5÷100) dB Metoda pomiarowa bezposrednia PN-EN ISO 1680:2014-02 PN-EN ISO 3744:2011 z wylaczeniem | PN-EN ISO 3743-1:2011 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/AP1:2017-09 PN-EN ISO 3747:2011 PN-EN 62271-202:2014-12 PN-EN 62271-202:2014 -12/ AC1:2015-07 PN-EN 60076-10:2017-01 IEC 60076-10:2016","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment Sound power level based on sound pressure level measurements Range: (16,5÷100) dB Direct measurement method PN-EN ISO 1680:2014-02 PN-EN ISO 3744:2011 z wyłączeniem | PN-EN ISO 3743-1:2011 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/AP1:2017-09 PN-EN ISO 3747:2011 PN-EN 62271-202:2014-12 PN-EN 62271-202:2014 -12/ AC1:2015-07 PN-EN 60076-10:2017-01 IEC 60076-10:2016"},{"_id":"6a5a55f19af9f73f38250efd","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Urządzenia komputerowe i biurowe, przeznaczone do trzymania w ręku, montowane na stole lub stojące na podłodze w odległości od ściany większej niż 1,5 m (z wyjątkiem maszyn do pisania, dalekopisów i klawiatur)","test_object_en":"Computer and office equipment, hand-held, table-mounted or floor-standing at a distance from the wall greater than 1,5 m (except typewriters, teleprinters and keyboards)","methodology":"Poziom mocy akustycznej na podstawie pomiarów poziomu ciśnienia akustycznego Zakres: (16,5÷100) dB Metoda pomiarowa bezpośrednia","methodology_en":"Sound power level based on sound pressure level measurements Range: (16,5÷100) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom mocy akustycznej na podstawie pomiarów poziomu ciśnienia akustycznego Zakres: (16,5÷100) dB Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 9295:2015-09 PN-EN ISO 7779:2019-03","norm_bases":["PN-EN ISO 9295:2015-09 PN-EN ISO 7779:2019-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia komputerowe i biurowe, przeznaczone do trzymania w ręku, montowane na stole lub stojące na podłodze w odległości od ściany większej niż 1,5 m (z wyjątkiem maszyn do pisania, dalekopisów i klawiatur) Poziom mocy akustycznej na podstawie pomiarów poziomu ciśnienia akustycznego Zakres: (16,5÷100) dB Metoda pomiarowa bezpośrednia PN-EN ISO 9295:2015-09 PN-EN ISO 7779:2019-03 Urzadzenia komputerowe i biurowe, przeznaczone do trzymania w reku, montowane na stole lub stojace na podlodze w odleglosci od sciany wiekszej niz 1,5 m (z wyjatkiem maszyn do pisania, dalekopisow i klawiatur) Poziom mocy akustycznej na podstawie pomiarow poziomu cisnienia akustycznego Zakres: (16,5÷100) dB Metoda pomiarowa bezposrednia PN-EN ISO 9295:2015-09 PN-EN ISO 7779:2019-03","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Computer and office equipment, hand-held, table-mounted or floor-standing at a distance from the wall greater than 1,5 m (except typewriters, teleprinters and keyboards) Sound power level based on sound pressure level measurements Range: (16,5÷100) dB Direct measurement method PN-EN ISO 9295:2015-09 PN-EN ISO 7779:2019-03"},{"_id":"6a5a55f19af9f73f38250efe","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne","test_object_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment","methodology":"Temperatura (- 60 ÷ +180) C Wilgotność do 98 %","methodology_en":"Temperature (- 60 ÷ +180) C Humidity up to 98 %","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura (- 60 ÷ +180) C Wilgotność do 98 %","reference":"PN-EN 60068-1:2014-06","norm_bases":["PN-EN 60068-1:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne Temperatura (- 60 ÷ +180) C Wilgotność do 98 % PN-EN 60068-1:2014-06 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe i informatyczne Temperatura (- 60 ÷ +180) C Wilgotnosc do 98 % PN-EN 60068-1:2014-06","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment Temperature (- 60 ÷ +180) C Humidity up to 98 % PN-EN 60068-1:2014-06","search_zh":"低压电气机器与设备，其中包括照明与信息技术设备 PN-EN 60068-1:2014-06","test_object_zh":"低压电气机器与设备，其中包括照明与信息技术设备"},{"_id":"6a5a55f19af9f73f38250eff","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne","test_object_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment","methodology":"Zimno","methodology_en":"Cold","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zimno","reference":"PN-EN 60068-2-1:2009","norm_bases":["PN-EN 60068-2-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne Zimno PN-EN 60068-2-1:2009 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe i informatyczne Zimno PN-EN 60068-2-1:2009","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment Cold PN-EN 60068-2-1:2009","search_zh":"低压电气机器与设备，其中包括照明与信息技术设备 PN-EN 60068-2-1:2009","test_object_zh":"低压电气机器与设备，其中包括照明与信息技术设备"},{"_id":"6a5a55f19af9f73f38250f00","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne","test_object_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment","methodology":"Suche gorąco","methodology_en":"Dry heat","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suche gorąco","reference":"PN-EN 60068-2-2:2009","norm_bases":["PN-EN 60068-2-2:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne Suche gorąco PN-EN 60068-2-2:2009 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe i informatyczne Suche goraco PN-EN 60068-2-2:2009","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment Dry heat PN-EN 60068-2-2:2009","search_zh":"低压电气机器与设备，其中包括照明与信息技术设备 PN-EN 60068-2-2:2009","test_object_zh":"低压电气机器与设备，其中包括照明与信息技术设备"},{"_id":"6a5a55f19af9f73f38250f01","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne","test_object_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment","methodology":"Wilgotne gorąco cykliczne(12h+12h)","methodology_en":"Damp heat, cyclic (12h+12h)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wilgotne gorąco cykliczne(12h+12h)","reference":"PN-EN 60068-2-30:2008","norm_bases":["PN-EN 60068-2-30:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne Wilgotne gorąco cykliczne(12h+12h) PN-EN 60068-2-30:2008 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe i informatyczne Wilgotne goraco cykliczne(12h+12h) PN-EN 60068-2-30:2008","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment Damp heat, cyclic (12h+12h) PN-EN 60068-2-30:2008","search_zh":"低压电气机器与设备，其中包括照明与信息技术设备 PN-EN 60068-2-30:2008","test_object_zh":"低压电气机器与设备，其中包括照明与信息技术设备"},{"_id":"6a5a55f19af9f73f38250f02","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne","test_object_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment","methodology":"Wilgotne gorąco stałe","methodology_en":"Damp heat, steady state","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wilgotne gorąco stałe","reference":"PN-EN 60068-2-78:2013-11","norm_bases":["PN-EN 60068-2-78:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne Wilgotne gorąco stałe PN-EN 60068-2-78:2013-11 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe i informatyczne Wilgotne goraco stale PN-EN 60068-2-78:2013-11","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment Damp heat, steady state PN-EN 60068-2-78:2013-11","search_zh":"低压电气机器与设备，其中包括照明与信息技术设备 PN-EN 60068-2-78:2013-11","test_object_zh":"低压电气机器与设备，其中包括照明与信息技术设备"},{"_id":"6a5a55f19af9f73f38250f03","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne","test_object_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment","methodology":"Zmiany temperatury","methodology_en":"Temperature changes","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmiany temperatury","reference":"PN-EN IEC 60068-2-14:2024-04","norm_bases":["PN-EN IEC 60068-2-14:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne Zmiany temperatury PN-EN IEC 60068-2-14:2024-04 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe i informatyczne Zmiany temperatury PN-EN IEC 60068-2-14:2024-04","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment Temperature changes PN-EN IEC 60068-2-14:2024-04","search_zh":"低压电气机器与设备，其中包括照明与信息技术设备 PN-EN IEC 60068-2-14:2024-04","test_object_zh":"低压电气机器与设备，其中包括照明与信息技术设备"},{"_id":"6a5a55f19af9f73f38250f04","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne","test_object_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment","methodology":"Odporność na wnikanie ciał stałych, pyłu i wilgoci do IP 68","methodology_en":"Resistance to ingress of solid objects, dust and moisture up to IP 68","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wnikanie ciał stałych, pyłu i wilgoci do IP 68","reference":"PN-EN 60529:2003 PN-EN 60529:2003/A2:2014-07 Z wyłączeniem stopnia ochrony IP X9 (pkt 14)","norm_bases":["PN-EN 60529:2003 PN-EN 60529:2003/A2:2014-07 Z wyłączeniem stopnia ochrony IP X9 (pkt 14)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe i informatyczne Odporność na wnikanie ciał stałych, pyłu i wilgoci do IP 68 PN-EN 60529:2003 PN-EN 60529:2003/A2:2014-07 Z wyłączeniem stopnia ochrony IP X9 (pkt 14) Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe i informatyczne Odpornosc na wnikanie cial stalych, pylu i wilgoci do IP 68 PN-EN 60529:2003 PN-EN 60529:2003/A2:2014-07 Z wylaczeniem stopnia ochrony IP X9 (pkt 14)","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting and information technology equipment Resistance to ingress of solid objects, dust and moisture up to IP 68 PN-EN 60529:2003 PN-EN 60529:2003/A2:2014-07 Z wyłączeniem stopnia ochrony IP X9 (pkt 14)","search_zh":"低压电气机器与设备，其中包括照明与信息技术设备 PN-EN 60529:2003 PN-EN 60529:2003/A2:2014-07 Z wyłączeniem stopnia ochrony IP X9 (pkt 14)","test_object_zh":"低压电气机器与设备，其中包括照明与信息技术设备"},{"_id":"6a5a55f19af9f73f38250f05","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Wyroby elektrotechniczne","test_object_en":"Electrotechnical products","methodology":"Badanie rozżarzonym drutem","methodology_en":"Glow-wire test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie rozżarzonym drutem","reference":"PN-EN IEC 60695-2-10:2022-07 PN-EN IEC 60695-2-11:2022-07 PN-EN IEC 60695-2-12:2022-06 PN-EN IEC 60695-2-13:2022-05","norm_bases":["PN-EN IEC 60695-2-10:2022-07 PN-EN IEC 60695-2-11:2022-07 PN-EN IEC 60695-2-12:2022-06 PN-EN IEC 60695-2-13:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne Badanie rozżarzonym drutem PN-EN IEC 60695-2-10:2022-07 PN-EN IEC 60695-2-11:2022-07 PN-EN IEC 60695-2-12:2022-06 PN-EN IEC 60695-2-13:2022-05 Wyroby elektrotechniczne Badanie rozzarzonym drutem PN-EN IEC 60695-2-10:2022-07 PN-EN IEC 60695-2-11:2022-07 PN-EN IEC 60695-2-12:2022-06 PN-EN IEC 60695-2-13:2022-05","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrotechnical products Glow-wire test PN-EN IEC 60695-2-10:2022-07 PN-EN IEC 60695-2-11:2022-07 PN-EN IEC 60695-2-12:2022-06 PN-EN IEC 60695-2-13:2022-05","search_zh":"电工产品 PN-EN IEC 60695-2-10:2022-07 PN-EN IEC 60695-2-11:2022-07 PN-EN IEC 60695-2-12:2022-06 PN-EN IEC 60695-2-13:2022-05","test_object_zh":"电工产品"},{"_id":"6a5a55f19af9f73f38250f06","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Wyroby elektrotechniczne","test_object_en":"Electrotechnical products","methodology":"Próba wciskania kulki","methodology_en":"Ball pressure test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba wciskania kulki","reference":"PN-EN 60695-10-2:2014-10","norm_bases":["PN-EN 60695-10-2:2014-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne Próba wciskania kulki PN-EN 60695-10-2:2014-10 Wyroby elektrotechniczne Proba wciskania kulki PN-EN 60695-10-2:2014-10","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrotechnical products Ball pressure test PN-EN 60695-10-2:2014-10","search_zh":"电工产品 PN-EN 60695-10-2:2014-10","test_object_zh":"电工产品"},{"_id":"6a5a55f19af9f73f38250f07","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Wyroby elektrotechniczne","test_object_en":"Electrotechnical products","methodology":"Badanie płomieniem igłowym","methodology_en":"Needle-flame test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie płomieniem igłowym","reference":"PN-EN 60695-11-5:2017-08","norm_bases":["PN-EN 60695-11-5:2017-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne Badanie płomieniem igłowym PN-EN 60695-11-5:2017-08 Wyroby elektrotechniczne Badanie plomieniem iglowym PN-EN 60695-11-5:2017-08","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrotechnical products Needle-flame test PN-EN 60695-11-5:2017-08","search_zh":"电工产品 PN-EN 60695-11-5:2017-08","test_object_zh":"电工产品"},{"_id":"6a5a55f19af9f73f38250f08","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Wyroby elektrotechniczne","test_object_en":"Electrotechnical products","methodology":"Odporność na prądy pełzające","methodology_en":"Resistance to tracking currents","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na prądy pełzające","reference":"PN-EN 60112:2021-07","norm_bases":["PN-EN 60112:2021-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne Odporność na prądy pełzające PN-EN 60112:2021-07 Wyroby elektrotechniczne Odpornosc na prady pelzajace PN-EN 60112:2021-07","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrotechnical products Resistance to tracking currents PN-EN 60112:2021-07","search_zh":"电工产品 PN-EN 60112:2021-07","test_object_zh":"电工产品"},{"_id":"6a5a55f19af9f73f38250f09","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Emisja zaburzeń przewodzonych: - emisja zaburzeń przewodzonych ciągłych od 9 kHz do 30 MHz - moc zaburzeń (30÷300) MHz - tłumienność wtrąceniowa opraw oświetleniowych -wahania napięcia i migotanie światła (flicker) - harmoniczne prądu do 39 harmonicznej - promieniowane zaburzenia elektromagnetyczne sprzętu oświetleniowego w zakresie od 9 kHz do 30 MHz","methodology_en":"Emission of conducted disturbances: - emission of continuous conducted disturbances from 9 kHz to 30 MHz - disturbance power (30÷300) MHz - insertion loss of luminaires - voltage fluctuations and flicker - current harmonics up to the 39th harmonic - radiated electromagnetic disturbances of lighting equipment in the range from 9 kHz to 30 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja zaburzeń przewodzonych: - emisja zaburzeń przewodzonych ciągłych od 9 kHz do 30 MHz - moc zaburzeń (30÷300) MHz - tłumienność wtrąceniowa opraw oświetleniowych -wahania napięcia i migotanie światła (flicker) - harmoniczne prądu do 39 harmonicznej - promieniowane zaburzenia elektromagnetyczne sprzętu oświetleniowego w zakresie od 9 kHz do 30 MHz","reference":"PN-EN IEC 61000-6-3:2021-08 PN-EN 61000-6-4:2008 PN-EN 61000-6-4:2008/A1:2012 PN-EN 61000-6-4:2019-12 PN-EN 55014-1:2021-08 PN-EN 55014-1:2017-06 PN-EN 55015 :2019-10/A11:2020 PN-EN 55015:2013-10/A1:2015-08 PN-EN 55015:2019-11 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 50561-1:2013-12 PN-EN 50121-1:2015-10 PN-EN 50121-1:2017-06 PN-EN 50121-2:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019- 07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019- 10 PN-EN 61000-3-2:2014-10 PN-EN 61000-3-2:2019-04 PN-EN 55022:2011 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN 61326-2-1:2013-07 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej.","norm_bases":["PN-EN IEC 61000-6-3:2021-08 PN-EN 61000-6-4:2008 PN-EN 61000-6-4:2008/A1:2012 PN-EN 61000-6-4:2019-12 PN-EN 55014-1:2021-08 PN-EN 55014-1:2017-06 PN-EN 55015 :2019-10/A11:2020 PN-EN 55015:2013-10/A1:2015-08 PN-EN 55015:2019-11 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 50561-1:2013-12 PN-EN 50121-1:2015-10 PN-EN 50121-1:2017-06 PN-EN 50121-2:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019- 07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019- 10 PN-EN 61000-3-2:2014-10 PN-EN 61000-3-2:2019-04 PN-EN 55022:2011 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04","PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN 61326-2-1:2013-07 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Emisja zaburzeń przewodzonych: - emisja zaburzeń przewodzonych ciągłych od 9 kHz do 30 MHz - moc zaburzeń (30÷300) MHz - tłumienność wtrąceniowa opraw oświetleniowych -wahania napięcia i migotanie światła (flicker) - harmoniczne prądu do 39 harmonicznej - promieniowane zaburzenia elektromagnetyczne sprzętu oświetleniowego w zakresie od 9 kHz do 30 MHz PN-EN IEC 61000-6-3:2021-08 PN-EN 61000-6-4:2008 PN-EN 61000-6-4:2008/A1:2012 PN-EN 61000-6-4:2019-12 PN-EN 55014-1:2021-08 PN-EN 55014-1:2017-06 PN-EN 55015 :2019-10/A11:2020 PN-EN 55015:2013-10/A1:2015-08 PN-EN 55015:2019-11 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 50561-1:2013-12 PN-EN 50121-1:2015-10 PN-EN 50121-1:2017-06 PN-EN 50121-2:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019- 07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019- 10 PN-EN 61000-3-2:2014-10 PN-EN 61000-3-2:2019-04 PN-EN 55022:2011 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN 61326-2-1:2013-07 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej. Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Emisja zaburzen przewodzonych: - emisja zaburzen przewodzonych ciaglych od 9 kHz do 30 MHz - moc zaburzen (30÷300) MHz - tlumiennosc wtraceniowa opraw oswietleniowych -wahania napiecia i migotanie swiatla (flicker) - harmoniczne pradu do 39 harmonicznej - promieniowane zaburzenia elektromagnetyczne sprzetu oswietleniowego w zakresie od 9 kHz do 30 MHz PN-EN IEC 61000-6-3:2021-08 PN-EN 61000-6-4:2008 PN-EN 61000-6-4:2008/A1:2012 PN-EN 61000-6-4:2019-12 PN-EN 55014-1:2021-08 PN-EN 55014-1:2017-06 PN-EN 55015 :2019-10/A11:2020 PN-EN 55015:2013-10/A1:2015-08 PN-EN 55015:2019-11 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 50561-1:2013-12 PN-EN 50121-1:2015-10 PN-EN 50121-1:2017-06 PN-EN 50121-2:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019- 07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019- 10 PN-EN 61000-3-2:2014-10 PN-EN 61000-3-2:2019-04 PN-EN 55022:2011 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN 61326-2-1:2013-07 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wylaczeniem punktow dotyczacych pomiaru emisji promieniowanej oraz badania odpornosci na promieniowane pole elektromagnetyczne o czestotliwosci radiowej.","categories":["environment"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Emission of conducted disturbances: - emission of continuous conducted disturbances from 9 kHz to 30 MHz - disturbance power (30÷300) MHz - insertion loss of luminaires - voltage fluctuations and flicker - current harmonics up to the 39th harmonic - radiated electromagnetic disturbances of lighting equipment in the range from 9 kHz to 30 MHz PN-EN IEC 61000-6-3:2021-08 PN-EN 61000-6-4:2008 PN-EN 61000-6-4:2008/A1:2012 PN-EN 61000-6-4:2019-12 PN-EN 55014-1:2021-08 PN-EN 55014-1:2017-06 PN-EN 55015 :2019-10/A11:2020 PN-EN 55015:2013-10/A1:2015-08 PN-EN 55015:2019-11 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 50561-1:2013-12 PN-EN 50121-1:2015-10 PN-EN 50121-1:2017-06 PN-EN 50121-2:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019- 07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019- 10 PN-EN 61000-3-2:2014-10 PN-EN 61000-3-2:2019-04 PN-EN 55022:2011 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN 61326-2-1:2013-07 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej.","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) PN-EN IEC 61000-6-3:2021-08 PN-EN 61000-6-4:2008 PN-EN 61000-6-4:2008/A1:2012 PN-EN 61000-6-4:2019-12 PN-EN 55014-1:2021-08 PN-EN 55014-1:2017-06 PN-EN 55015 :2019-10/A11:2020 PN-EN 55015:2013-10/A1:2015-08 PN-EN 55015:2019-11 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 50561-1:2013-12 PN-EN 50121-1:2015-10 PN-EN 50121-1:2017-06 PN-EN 50121-2:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019- 07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019- 10 PN-EN 61000-3-2:2014-10 PN-EN 61000-3-2:2019-04 PN-EN 55022:2011 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN 61326-2-1:2013-07 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej.","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)"},{"_id":"6a5a55f19af9f73f38250f0a","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na zaburzenia elektromagnetyczne: - wyładowania elektrostatyczne (ESD) kontaktowe i powietrzu ± 30kV - serie szybkich elektrycznych stanów przejściowych (BURST) - udary (SURGE) - odporność na zaburzenia indukowane o częstotliwości radiowej - zapady, krótkie przerwy i zmiany napięcia","methodology_en":"Immunity to electromagnetic disturbances: - electrostatic discharge (ESD) contact and air ± 30kV - electrical fast transients (BURST) - surges (SURGE) - immunity to radio-frequency induced disturbances - voltage dips, short interruptions and voltage variations","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia elektromagnetyczne: - wyładowania elektrostatyczne (ESD) kontaktowe i powietrzu ± 30kV - serie szybkich elektrycznych stanów przejściowych (BURST) - udary (SURGE) - odporność na zaburzenia indukowane o częstotliwości radiowej - zapady, krótkie przerwy i zmiany napięcia","reference":"PN-EN IEC 55014-2:2021-08 PN-EN IEC 55035:2017-09 PN-EN IEC 55035:2017-09/A11:2020- 09 PN-EN IEC 61000-4-11:2020-11 PN-EN 55024:2011 PN-EN 55024:2011/A1:2015-08 PN-EN 61000-6-1:2008 PN-EN 61000-6-1:2019-03 PN-EN 61000-6-2:2008 PN-EN 61000-6-2:2019-04 PN-EN 61547:2009 PN-EN 50121-1:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019-07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-4:2017-04/A1:2019-07 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-4-2 :2011 PN-EN 61000-4-4:2013-05 PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5 2014-10/A1:2018-01 PN-EN 61000-4-6:2014-04 PN-EN 61000-4-11:2007 PN-EN 61000-4-11:2007/A1:2017-09 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN IEC 61326-2-1:2021-10 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej.","norm_bases":["PN-EN IEC 55014-2:2021-08 PN-EN IEC 55035:2017-09 PN-EN IEC 55035:2017-09/A11:2020- 09 PN-EN IEC 61000-4-11:2020-11 PN-EN 55024:2011 PN-EN 55024:2011/A1:2015-08 PN-EN 61000-6-1:2008 PN-EN 61000-6-1:2019-03 PN-EN 61000-6-2:2008 PN-EN 61000-6-2:2019-04 PN-EN 61547:2009 PN-EN 50121-1:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019-07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-4:2017-04/A1:2019-07 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-4-2 :2011 PN-EN 61000-4-4:2013-05 PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5 2014-10/A1:2018-01 PN-EN 61000-4-6:2014-04 PN-EN 61000-4-11:2007 PN-EN 61000-4-11:2007/A1:2017-09 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04","PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN IEC 61326-2-1:2021-10 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na zaburzenia elektromagnetyczne: - wyładowania elektrostatyczne (ESD) kontaktowe i powietrzu ± 30kV - serie szybkich elektrycznych stanów przejściowych (BURST) - udary (SURGE) - odporność na zaburzenia indukowane o częstotliwości radiowej - zapady, krótkie przerwy i zmiany napięcia PN-EN IEC 55014-2:2021-08 PN-EN IEC 55035:2017-09 PN-EN IEC 55035:2017-09/A11:2020- 09 PN-EN IEC 61000-4-11:2020-11 PN-EN 55024:2011 PN-EN 55024:2011/A1:2015-08 PN-EN 61000-6-1:2008 PN-EN 61000-6-1:2019-03 PN-EN 61000-6-2:2008 PN-EN 61000-6-2:2019-04 PN-EN 61547:2009 PN-EN 50121-1:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019-07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-4:2017-04/A1:2019-07 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-4-2 :2011 PN-EN 61000-4-4:2013-05 PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5 2014-10/A1:2018-01 PN-EN 61000-4-6:2014-04 PN-EN 61000-4-11:2007 PN-EN 61000-4-11:2007/A1:2017-09 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN IEC 61326-2-1:2021-10 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej. Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na zaburzenia elektromagnetyczne: - wyladowania elektrostatyczne (ESD) kontaktowe i powietrzu ± 30kV - serie szybkich elektrycznych stanow przejsciowych (BURST) - udary (SURGE) - odpornosc na zaburzenia indukowane o czestotliwosci radiowej - zapady, krotkie przerwy i zmiany napiecia PN-EN IEC 55014-2:2021-08 PN-EN IEC 55035:2017-09 PN-EN IEC 55035:2017-09/A11:2020- 09 PN-EN IEC 61000-4-11:2020-11 PN-EN 55024:2011 PN-EN 55024:2011/A1:2015-08 PN-EN 61000-6-1:2008 PN-EN 61000-6-1:2019-03 PN-EN 61000-6-2:2008 PN-EN 61000-6-2:2019-04 PN-EN 61547:2009 PN-EN 50121-1:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019-07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-4:2017-04/A1:2019-07 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-4-2 :2011 PN-EN 61000-4-4:2013-05 PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5 2014-10/A1:2018-01 PN-EN 61000-4-6:2014-04 PN-EN 61000-4-11:2007 PN-EN 61000-4-11:2007/A1:2017-09 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN IEC 61326-2-1:2021-10 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wylaczeniem punktow dotyczacych pomiaru emisji promieniowanej oraz badania odpornosci na promieniowane pole elektromagnetyczne o czestotliwosci radiowej.","categories":["environment"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to electromagnetic disturbances: - electrostatic discharge (ESD) contact and air ± 30kV - electrical fast transients (BURST) - surges (SURGE) - immunity to radio-frequency induced disturbances - voltage dips, short interruptions and voltage variations PN-EN IEC 55014-2:2021-08 PN-EN IEC 55035:2017-09 PN-EN IEC 55035:2017-09/A11:2020- 09 PN-EN IEC 61000-4-11:2020-11 PN-EN 55024:2011 PN-EN 55024:2011/A1:2015-08 PN-EN 61000-6-1:2008 PN-EN 61000-6-1:2019-03 PN-EN 61000-6-2:2008 PN-EN 61000-6-2:2019-04 PN-EN 61547:2009 PN-EN 50121-1:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019-07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-4:2017-04/A1:2019-07 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-4-2 :2011 PN-EN 61000-4-4:2013-05 PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5 2014-10/A1:2018-01 PN-EN 61000-4-6:2014-04 PN-EN 61000-4-11:2007 PN-EN 61000-4-11:2007/A1:2017-09 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN IEC 61326-2-1:2021-10 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej.","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) PN-EN IEC 55014-2:2021-08 PN-EN IEC 55035:2017-09 PN-EN IEC 55035:2017-09/A11:2020- 09 PN-EN IEC 61000-4-11:2020-11 PN-EN 55024:2011 PN-EN 55024:2011/A1:2015-08 PN-EN 61000-6-1:2008 PN-EN 61000-6-1:2019-03 PN-EN 61000-6-2:2008 PN-EN 61000-6-2:2019-04 PN-EN 61547:2009 PN-EN 50121-1:2015-10 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019-07 PN-EN 50121-4:2015-10 PN-EN 50121-4:2017-04 PN-EN 50121-4:2017-04/A1:2019-07 PN-EN 50121-5:2015-10 PN-EN 50121-5:2017-05 PN-EN 61000-4-2 :2011 PN-EN 61000-4-4:2013-05 PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5 2014-10/A1:2018-01 PN-EN 61000-4-6:2014-04 PN-EN 61000-4-11:2007 PN-EN 61000-4-11:2007/A1:2017-09 PN-EN 60601-1-2:2015-11 PN-EN 50130-4:2012 PN-EN 50130-4:2012/A1:2015-03 PN-EN 50270:2015-04 PN-EN 50550:2011 PN-EN 50550:2011/A1:2015-04 | PN-EN 61204-3:2019-02 PN-EN IEC 61326-1:2021-10 PN-EN IEC 61326-2-1:2021-10 PN-EN IEC 61326-2-2:2021-11 PN-EN IEC 61326-2-3:2021-11 PN-EN 61326-2-4:2021-11 PN-EN IEC 61326-2-5:2021-11 – z wyłączeniem punktów dotyczących pomiaru emisji promieniowanej oraz badania odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej.","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)"},{"_id":"6a5a55f19af9f73f38250f0b","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na zapady i zmiany napięcia na przyłączu zasilania","methodology_en":"Immunity to voltage dips and voltage variations at the power port","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady i zmiany napięcia na przyłączu zasilania","reference":"PN-EN 61000-4-29:2004","norm_bases":["PN-EN 61000-4-29:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na zapady i zmiany napięcia na przyłączu zasilania PN-EN 61000-4-29:2004 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na zapady i zmiany napiecia na przylaczu zasilania PN-EN 61000-4-29:2004","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to voltage dips and voltage variations at the power port PN-EN 61000-4-29:2004","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) PN-EN 61000-4-29:2004","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)"},{"_id":"6a5a55f19af9f73f38250f0c","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","reference":"PN-EN 61000-4-8:2010","norm_bases":["PN-EN 61000-4-8:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej PN-EN 61000-4-8:2010 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej PN-EN 61000-4-8:2010","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to power-frequency magnetic field PN-EN 61000-4-8:2010","methodology_zh":"工频磁场抗扰度","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) 工频磁场抗扰度 PN-EN 61000-4-8:2010","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)"},{"_id":"6a5a55f19af9f73f38250f0d","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na impulsowe pole magnetyczne","methodology_en":"Immunity to pulse magnetic field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na impulsowe pole magnetyczne","reference":"PN-EN 61000-4-9:2016-11","norm_bases":["PN-EN 61000-4-9:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na impulsowe pole magnetyczne PN-EN 61000-4-9:2016-11 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na impulsowe pole magnetyczne PN-EN 61000-4-9:2016-11","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to pulse magnetic field PN-EN 61000-4-9:2016-11","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) 脉冲磁场抗扰度 PN-EN 61000-4-9:2016-11","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)","methodology_zh":"脉冲磁场抗扰度"},{"_id":"6a5a55f19af9f73f38250f0e","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na tłumiony przebieg oscylacyjny","methodology_en":"Immunity to damped oscillatory wave","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na tłumiony przebieg oscylacyjny","reference":"PN-EN 61000-4-18:2009 PN-EN 61000-4-18:2009/A1:2011 PN-EN 61000-4-18:2019-08","norm_bases":["PN-EN 61000-4-18:2009 PN-EN 61000-4-18:2009/A1:2011 PN-EN 61000-4-18:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na tłumiony przebieg oscylacyjny PN-EN 61000-4-18:2009 PN-EN 61000-4-18:2009/A1:2011 PN-EN 61000-4-18:2019-08 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na tlumiony przebieg oscylacyjny PN-EN 61000-4-18:2009 PN-EN 61000-4-18:2009/A1:2011 PN-EN 61000-4-18:2019-08","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to damped oscillatory wave PN-EN 61000-4-18:2009 PN-EN 61000-4-18:2009/A1:2011 PN-EN 61000-4-18:2019-08","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) 阻尼振荡波抗扰度 PN-EN 61000-4-18:2009 PN-EN 61000-4-18:2009/A1:2011 PN-EN 61000-4-18:2019-08","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)","methodology_zh":"阻尼振荡波抗扰度"},{"_id":"6a5a55f19af9f73f38250f0f","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na asymetryczne zaburzenia przewodzone o częstotliwości od 0 Hz do 150 kHz","methodology_en":"Immunity to conducted common mode disturbances at frequencies from 0 Hz to 150 kHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na asymetryczne zaburzenia przewodzone o częstotliwości od 0 Hz do 150 kHz","reference":"PN-EN 61000-4-16:2016-05","norm_bases":["PN-EN 61000-4-16:2016-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na asymetryczne zaburzenia przewodzone o częstotliwości od 0 Hz do 150 kHz PN-EN 61000-4-16:2016-05 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na asymetryczne zaburzenia przewodzone o czestotliwosci od 0 Hz do 150 kHz PN-EN 61000-4-16:2016-05","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to conducted common mode disturbances at frequencies from 0 Hz to 150 kHz PN-EN 61000-4-16:2016-05","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) PN-EN 61000-4-16:2016-05","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)"},{"_id":"6a5a55f19af9f73f38250f10","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na zaburzenia małej częstotliwości","methodology_en":"Immunity to low-frequency disturbances","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia małej częstotliwości","reference":"PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05","norm_bases":["PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na zaburzenia małej częstotliwości PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na zaburzenia malej czestotliwosci PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to low-frequency disturbances PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) 低频骚扰抗扰度 PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)","methodology_zh":"低频骚扰抗扰度"},{"_id":"6a5a55f19af9f73f38250f11","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na wahania napięcia","methodology_en":"Immunity to voltage fluctuations","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wahania napięcia","reference":"PN-EN 61000-4-14:2002 +A1:2006+A2:2010","norm_bases":["PN-EN 61000-4-14:2002 +A1:2006+A2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na wahania napięcia PN-EN 61000-4-14:2002 +A1:2006+A2:2010 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na wahania napiecia PN-EN 61000-4-14:2002 +A1:2006+A2:2010","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to voltage fluctuations PN-EN 61000-4-14:2002 +A1:2006+A2:2010","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) PN-EN 61000-4-14:2002 +A1:2006+A2:2010","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)"},{"_id":"6a5a55f19af9f73f38250f12","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na obecność składowej zmiennej w stałym napięciu zasilającym","methodology_en":"Immunity to ripple on the DC input power port","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obecność składowej zmiennej w stałym napięciu zasilającym","reference":"PN-EN 61000-4-17:2004 +A1:2006+A2:2011","norm_bases":["PN-EN 61000-4-17:2004 +A1:2006+A2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na obecność składowej zmiennej w stałym napięciu zasilającym PN-EN 61000-4-17:2004 +A1:2006+A2:2011 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na obecnosc skladowej zmiennej w stalym napieciu zasilajacym PN-EN 61000-4-17:2004 +A1:2006+A2:2011","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to ripple on the DC input power port PN-EN 61000-4-17:2004 +A1:2006+A2:2011","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) PN-EN 61000-4-17:2004 +A1:2006+A2:2011","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)"},{"_id":"6a5a55f19af9f73f38250f13","lab_id":"69ad52a3de79e566650fb0cd","country":"PL","accr_number":"AB 022","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *)","test_object_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *)","methodology":"Odporność na zmiany częstotliwości sieci zasilającej","methodology_en":"Immunity to power frequency variations","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zmiany częstotliwości sieci zasilającej","reference":"PN-EN 61000-4-28:2004 +A1:2006+A2:2011","norm_bases":["PN-EN 61000-4-28:2004 +A1:2006+A2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia elektryczne niskiego napięcia w tym urządzenia oświetleniowe, informatyczne oraz trakcyjne *) Odporność na zmiany częstotliwości sieci zasilającej PN-EN 61000-4-28:2004 +A1:2006+A2:2011 Maszyny i urzadzenia elektryczne niskiego napiecia w tym urzadzenia oswietleniowe, informatyczne oraz trakcyjne *) Odpornosc na zmiany czestotliwosci sieci zasilajacej PN-EN 61000-4-28:2004 +A1:2006+A2:2011","categories":["other"],"row_index":57,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Low-voltage electrical machines and equipment, including lighting, information technology and traction equipment *) Immunity to power frequency variations PN-EN 61000-4-28:2004 +A1:2006+A2:2011","search_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *) PN-EN 61000-4-28:2004 +A1:2006+A2:2011","test_object_zh":"低压电气机器与设备，其中包括照明、信息技术与牵引设备 *)"}],"has_pdf":true}