🇨🇿 DATA ELEKTRONIK, spol. s r.o. PL

ČIA 2432 • Brno, Czech Republic • 3 calibration items

Metrology & calibration

DATA ELEKTRONIK, spol. s r.o. is a calibration laboratory accredited by ČIA under number 2432 (Brno, Czech Republic). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Indication thermometers including temperature measuring chains, exc…, Relative humidity meters, excluding psychrometers. Most frequently used calibration principles: Comparative measurements with a reference humidity meter in a humid…, Comparison with a reference digital thermometer in a climatic chamber, Comparison with a reference digital thermometer in a liquid bath.

At a glance

  • Accreditation number: ČIA 2432
  • Calibration items in scope: 3
  • Types of calibrated items: 2
  • Calibration principles used: 3
  • City: Brno, Czech Republic
  • Valid until: 03-09-2029
Accreditation number
2432
Accreditation body
ČIA
Address
Jugoslávská 669/113, Černá Pole, 613 00 Brno
City
Brno, Czech Republic
Division
Laboratorium wzorcujące DATA ELEKTRONIK
Valid until
03-09-2029

What this laboratory calibrates (2)

Calibration principles (3)

Certificate information

Certificate date
03.09.2026

Accreditation scope — calibration items (3)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Indication thermometers including temperature measuring chains, excluding glass thermometers Calibration – temperature
-25 °C to 140 °C · CMC 0,06 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in a liquid bath DAT_C_KP-01_Teplota_03
2 Indication thermometers including temperature measuring chains, excluding glass thermometers Calibration – temperature
-40 °C to 0 °C · CMC 0,50 °C 0 °C to 60 °C · CMC 0,13 °C 60 °C to 180 °C · CMC 0,34 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in a climatic chamber DAT_C_KP-01_Teplota_03
3 Relative humidity meters, excluding psychrometers Calibration – air humidity
(10 to 40) °C — 10 % RH to 30 % RH · CMC 1,1 % RH (10 to 40) °C — 30 % RH to 80 % RH · CMC 1,2 % RH (10 to 40) °C — 80 % RH to 95 % RH · CMC 1,8 % RH
CMC for the field of measured quantity: Air humidity
Comparative measurements with a reference humidity meter in a humidity generator DAT_C_KP-02_Vlhkost_03

Reference standards (2)

DAT_C_KP-01_Teplota_03
DAT_C_KP-02_Vlhkost_03

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2432