{"lab":{"_id":"6ade8b5dff06824761708158","country":"CZ","accr_number":"2432","accr_body":"ČIA","address":"Jugoslávská 669/113, Černá Pole, 613 00 Brno","categories":["metrology"],"city":"Brno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.6224591,49.2131387]},"map_coord":[49.2131387,16.6224591],"map_geo":"cai-mapa","methods_count":3,"name":"DATA ELEKTRONIK, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie temperatury i wilgotności względnej, w zakresie określonym w załączniku do świadectwa.","search_text":"data elektronik, spol. s r.o. jugoslávská 669/113, černá pole, 613 00 brno 2432","source_page_url":"https://www.cai.cz/?subjekt=2432-data-elektronik-spol-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"03-09-2029","website":"www.datel.cz","certificate_date":"03.09.2026","certificate_no":"418/2026","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie temperatury i wilgotności względnej, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of temperature and relative humidity to the extent as specified in the appendix to this Certificate.","zh":"温度和相对湿度领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru teplota a relativní vlhkost, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące DATA ELEKTRONIK","lab_division_cs":"Kalibrační laboratoř DATA ELEKTRONIK","lab_division_en":"DATA ELEKTRONIK Calibration Laboratory","lab_division_zh":"DATA ELEKTRONIK 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"648986f6abbe0d1fe66ad438d979345f3adaa494482a78f7533252b3975e70a5","source_pdf_url":"https://www.cai.cz/OA/pdf/418_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/418_2026_EN.pdf"},"methods":[{"_id":"b897628e110e94ae65c00ac2","lab_id":"6ade8b5dff06824761708158","country":"CZ","accr_number":"2432","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące wraz z torami pomiarowymi, z wyjątkiem termometrów szklanych","test_object_en":"Indication thermometers including temperature measuring chains, excluding glass thermometers","test_object_zh":"指示式温度计（包括测量链，玻璃温度计除外）","test_object_cs":"Indikační teploměry včetně měřících řetězců vyjma skleněných teploměrů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -25 °C do 140 °C","cmc":"0,06 °C"}],"parameters_en":[{"name":"","range":"-25 °C to 140 °C","cmc":"0,06 °C"}],"parameters_zh":[{"name":"","range":"-25 °C 至 140 °C","cmc":"0,06 °C"}],"parameters_cs":[{"name":"","range":"-25 °C až 140 °C","cmc":"0,06 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a reference digital thermometer in a liquid bath","technique_zh":"在液体槽中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v kapalinové lázni","techniques":["Porównanie z cyfrowym termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a reference digital thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -25 °C do 140 °C CMC 0,06 °C\nPorównanie z cyfrowym termometrem wzorcowym w łaźni cieczowej","reference":"DAT_C_KP-01_Teplota_03","norm_bases":["DAT_C_KP-01_Teplota_03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące wraz z torami pomiarowymi, z wyjątkiem termometrów szklanych Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym w łaźni cieczowej od -25 °C do 140 °C CMC 0,06 °C Indikační teploměry včetně měřících řetězců vyjma skleněných teploměrů Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v kapalinové lázni -25 °C až 140 °C CMC 0,06 °C DAT_C_KP-01_Teplota_03 Termometry wskazujace wraz z torami pomiarowymi, z wyjatkiem termometrow szklanych Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym w lazni cieczowej od -25 °C do 140 °C CMC 0,06 °C Indikacni teplomery vcetne mericich retezcu vyjma sklenenych teplomeru Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v kapalinove lazni -25 °C az 140 °C CMC 0,06 °C DAT_C_KP-01_Teplota_03","search_en":"Indication thermometers including temperature measuring chains, excluding glass thermometers Calibration – temperature Comparison with a reference digital thermometer in a liquid bath -25 °C to 140 °C CMC 0,06 °C DAT_C_KP-01_Teplota_03","search_zh":"指示式温度计（包括测量链，玻璃温度计除外） 校准 – 温度 在液体槽中与标准数字温度计比较 -25 °C 至 140 °C CMC 0,06 °C DAT_C_KP-01_Teplota_03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"edf9863d09f8f95e356ada6c","lab_id":"6ade8b5dff06824761708158","country":"CZ","accr_number":"2432","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące wraz z torami pomiarowymi, z wyjątkiem termometrów szklanych","test_object_en":"Indication thermometers including temperature measuring chains, excluding glass thermometers","test_object_zh":"指示式温度计（包括测量链，玻璃温度计除外）","test_object_cs":"Indikační teploměry včetně měřících řetězců vyjma skleněných teploměrů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 0 °C","cmc":"0,50 °C"},{"name":"","range":"od 0 °C do 60 °C","cmc":"0,13 °C"},{"name":"","range":"od 60 °C do 180 °C","cmc":"0,34 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 0 °C","cmc":"0,50 °C"},{"name":"","range":"0 °C to 60 °C","cmc":"0,13 °C"},{"name":"","range":"60 °C to 180 °C","cmc":"0,34 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 0 °C","cmc":"0,50 °C"},{"name":"","range":"0 °C 至 60 °C","cmc":"0,13 °C"},{"name":"","range":"60 °C 至 180 °C","cmc":"0,34 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 0 °C","cmc":"0,50 °C"},{"name":"","range":"0 °C až 60 °C","cmc":"0,13 °C"},{"name":"","range":"60 °C až 180 °C","cmc":"0,34 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym w komorze klimatycznej","technique_en":"Comparison with a reference digital thermometer in a climatic chamber","technique_zh":"在气候箱中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v klimatické komoře","techniques":["Porównanie z cyfrowym termometrem wzorcowym w komorze klimatycznej"],"techniques_en":["Comparison with a reference digital thermometer in a climatic chamber"],"techniques_zh":["在气候箱中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do 0 °C CMC 0,50 °C\nod 0 °C do 60 °C CMC 0,13 °C\nod 60 °C do 180 °C CMC 0,34 °C\nPorównanie z cyfrowym termometrem wzorcowym w komorze klimatycznej","reference":"DAT_C_KP-01_Teplota_03","norm_bases":["DAT_C_KP-01_Teplota_03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące wraz z torami pomiarowymi, z wyjątkiem termometrów szklanych Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym w komorze klimatycznej od -40 °C do 0 °C CMC 0,50 °C od 0 °C do 60 °C CMC 0,13 °C od 60 °C do 180 °C CMC 0,34 °C Indikační teploměry včetně měřících řetězců vyjma skleněných teploměrů Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v klimatické komoře -40 °C až 0 °C CMC 0,50 °C 0 °C až 60 °C CMC 0,13 °C 60 °C až 180 °C CMC 0,34 °C DAT_C_KP-01_Teplota_03 Termometry wskazujace wraz z torami pomiarowymi, z wyjatkiem termometrow szklanych Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym w komorze klimatycznej od -40 °C do 0 °C CMC 0,50 °C od 0 °C do 60 °C CMC 0,13 °C od 60 °C do 180 °C CMC 0,34 °C Indikacni teplomery vcetne mericich retezcu vyjma sklenenych teplomeru Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v klimaticke komore -40 °C az 0 °C CMC 0,50 °C 0 °C az 60 °C CMC 0,13 °C 60 °C az 180 °C CMC 0,34 °C DAT_C_KP-01_Teplota_03","search_en":"Indication thermometers including temperature measuring chains, excluding glass thermometers Calibration – temperature Comparison with a reference digital thermometer in a climatic chamber -40 °C to 0 °C CMC 0,50 °C 0 °C to 60 °C CMC 0,13 °C 60 °C to 180 °C CMC 0,34 °C DAT_C_KP-01_Teplota_03","search_zh":"指示式温度计（包括测量链，玻璃温度计除外） 校准 – 温度 在气候箱中与标准数字温度计比较 -40 °C 至 0 °C CMC 0,50 °C 0 °C 至 60 °C CMC 0,13 °C 60 °C 至 180 °C CMC 0,34 °C DAT_C_KP-01_Teplota_03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0be8759f03bcc81175d6b2b9","lab_id":"6ade8b5dff06824761708158","country":"CZ","accr_number":"2432","accr_body":"ČIA","row_label":"1","test_object":"Mierniki wilgotności względnej z wyjątkiem psychrometrów","test_object_en":"Relative humidity meters, excluding psychrometers","test_object_zh":"相对湿度测量仪器（干湿球湿度计除外）","test_object_cs":"Měřidla relativní vlhkosti vyjma psychrometrů","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"(10 do 40) °C","range":"od 10 % RH do 30 % RH","cmc":"1,1 % RH"},{"name":"(10 do 40) °C","range":"od 30 % RH do 80 % RH","cmc":"1,2 % RH"},{"name":"(10 do 40) °C","range":"od 80 % RH do 95 % RH","cmc":"1,8 % RH"}],"parameters_en":[{"name":"(10 to 40) °C","range":"10 % RH to 30 % RH","cmc":"1,1 % RH"},{"name":"(10 to 40) °C","range":"30 % RH to 80 % RH","cmc":"1,2 % RH"},{"name":"(10 to 40) °C","range":"80 % RH to 95 % RH","cmc":"1,8 % RH"}],"parameters_zh":[{"name":"（10 至 40）°C","range":"10 % RH 至 30 % RH","cmc":"1,1 % RH"},{"name":"（10 至 40）°C","range":"30 % RH 至 80 % RH","cmc":"1,2 % RH"},{"name":"（10 至 40）°C","range":"80 % RH 至 95 % RH","cmc":"1,8 % RH"}],"parameters_cs":[{"name":"(10 až 40) °C","range":"10 % RH až 30 % RH","cmc":"1,1 % RH"},{"name":"(10 až 40) °C","range":"30 % RH až 80 % RH","cmc":"1,2 % RH"},{"name":"(10 až 40) °C","range":"80 % RH až 95 % RH","cmc":"1,8 % RH"}],"technique":"Pomiar porównawczy z higrometrem wzorcowym w generatorze wilgotności","technique_en":"Comparative measurements with a reference humidity meter in a humidity generator","technique_zh":"在湿度发生器中与标准湿度计比较测量","technique_cs":"Porovnávací měření s etalonovým vlhkoměrem v generátoru vlhkosti","techniques":["Pomiar porównawczy z higrometrem wzorcowym w generatorze wilgotności"],"techniques_en":["Comparative measurements with a reference humidity meter in a humidity generator"],"techniques_zh":["在湿度发生器中与标准湿度计比较测量"],"techniques_cs":["Porovnávací měření s etalonovým vlhkoměrem v generátoru vlhkosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\n(10 do 40) °C od 10 % RH do 30 % RH CMC 1,1 % RH\n(10 do 40) °C od 30 % RH do 80 % RH CMC 1,2 % RH\n(10 do 40) °C od 80 % RH do 95 % RH CMC 1,8 % RH\nPomiar porównawczy z higrometrem wzorcowym w generatorze wilgotności","reference":"DAT_C_KP-02_Vlhkost_03","norm_bases":["DAT_C_KP-02_Vlhkost_03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki wilgotności względnej z wyjątkiem psychrometrów Wzorcowanie – wilgotność powietrza Pomiar porównawczy z higrometrem wzorcowym w generatorze wilgotności (10 do 40) °C od 10 % RH do 30 % RH CMC 1,1 % RH (10 do 40) °C od 30 % RH do 80 % RH CMC 1,2 % RH (10 do 40) °C od 80 % RH do 95 % RH CMC 1,8 % RH Měřidla relativní vlhkosti vyjma psychrometrů Kalibrace – vlhkost vzduchu Porovnávací měření s etalonovým vlhkoměrem v generátoru vlhkosti (10 až 40) °C 10 % RH až 30 % RH CMC 1,1 % RH (10 až 40) °C 30 % RH až 80 % RH CMC 1,2 % RH (10 až 40) °C 80 % RH až 95 % RH CMC 1,8 % RH DAT_C_KP-02_Vlhkost_03 Mierniki wilgotnosci wzglednej z wyjatkiem psychrometrow Wzorcowanie – wilgotnosc powietrza Pomiar porownawczy z higrometrem wzorcowym w generatorze wilgotnosci (10 do 40) °C od 10 % RH do 30 % RH CMC 1,1 % RH (10 do 40) °C od 30 % RH do 80 % RH CMC 1,2 % RH (10 do 40) °C od 80 % RH do 95 % RH CMC 1,8 % RH Meridla relativni vlhkosti vyjma psychrometru Kalibrace – vlhkost vzduchu Porovnavaci mereni s etalonovym vlhkomerem v generatoru vlhkosti (10 az 40) °C 10 % RH az 30 % RH CMC 1,1 % RH (10 az 40) °C 30 % RH az 80 % RH CMC 1,2 % RH (10 az 40) °C 80 % RH az 95 % RH CMC 1,8 % RH DAT_C_KP-02_Vlhkost_03","search_en":"Relative humidity meters, excluding psychrometers Calibration – air humidity Comparative measurements with a reference humidity meter in a humidity generator (10 to 40) °C 10 % RH to 30 % RH CMC 1,1 % RH (10 to 40) °C 30 % RH to 80 % RH CMC 1,2 % RH (10 to 40) °C 80 % RH to 95 % RH CMC 1,8 % RH DAT_C_KP-02_Vlhkost_03","search_zh":"相对湿度测量仪器（干湿球湿度计除外） 校准 – 空气湿度 在湿度发生器中与标准湿度计比较测量 （10 至 40）°C 10 % RH 至 30 % RH CMC 1,1 % RH （10 至 40）°C 30 % RH 至 80 % RH CMC 1,2 % RH （10 至 40）°C 80 % RH 至 95 % RH CMC 1,8 % RH DAT_C_KP-02_Vlhkost_03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}