🇨🇿 SPECION, s.r.o. PL
Metrology & calibration
SPECION, s.r.o. is a calibration laboratory accredited by ČIA under number 2429 (Praha 4, Czech Republic). Its accreditation scope covers 2 calibration items in the following areas: Metrology & calibration. Calibrated items include: Air humidity meters and humidity measuring chains, including humidi…, Indicating thermometers, temperature measuring chains including the…. Most frequently used calibration principles: Comparison with a reference capacitive hygrometer in a climatic cha…, Comparison with a reference digital thermometer in a climatic chamber.
At a glance
- Accreditation number: ČIA 2429
- Calibration items in scope: 2
- Types of calibrated items: 2
- Calibration principles used: 2
- City: Praha 4, Czech Republic
- Valid until: 26-01-2029
- Accreditation number
- 2429
- Accreditation body
- ČIA
- Address
- Květnového vítězství 332/31, Chodov, 149 00 Praha 4
- City
- Praha 4, Czech Republic
- Division
- Laboratorium wzorcujące
- Valid until
- 26-01-2029
What this laboratory calibrates (2)
- Air humidity meters and humidity measuring chains, including humidity sensors of climatic chambers and enclosures, measurement of humidity in equipment with temperature and humidity control — 1 calibration item
- Indicating thermometers, temperature measuring chains including thermometers of thermal and climatic chambers and enclosures, measurement of temperature in equipment with temperature and humidity control — 1 calibration item
Calibration principles (2)
- Comparison with a reference capacitive hygrometer in a climatic chamber — 1 calibration item
- Comparison with a reference digital thermometer in a climatic chamber — 1 calibration item
Certificate information
- Certificate date
- 26.01.2026
Accreditation scope — calibration items (2)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Indicating thermometers, temperature measuring chains including thermometers of thermal and climatic chambers and enclosures, measurement of temperature in equipment with temperature and humidity control | Calibration – temperature -70 °C to -40 °C · CMC 0,40 °C -40 °C to 100 °C · CMC 0,35 °C 100 °C to 180 °C · CMC 0,40 °C 180 °C to 250 °C · CMC 0,90 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference digital thermometer in a climatic chamber | KP01 | |
| 2 | Air humidity meters and humidity measuring chains, including humidity sensors of climatic chambers and enclosures, measurement of humidity in equipment with temperature and humidity control | Calibration – air humidity Air temperature (15 to 30) °C — 10 % RH to 50 % RH · CMC 1,8 % RH Air temperature (30 to 60) °C — 10 % RH to 50 % RH · CMC 1,9 % RH Air temperature (60 to 90) °C — 10 % RH to 50 % RH · CMC 2,0 % RH Air temperature (15 to 30) °C — 50 % RH to 90 % RH · CMC 2,1 % RH Air temperature (30 to 60) °C — 50 % RH to 90 % RH · CMC 2,3 % RH Air temperature (60 to 90) °C — 50 % RH to 90 % RH · CMC 2,4 % RH Air temperature (15 to 30) °C — 90 % RH to 95 % RH · CMC 2,5 % RH Air temperature (30 to 60) °C — 90 % RH to 95 % RH · CMC 2,5 % RH Air temperature (60 to 90) °C — 90 % RH to 95 % RH · CMC 2,7 % RH CMC for the field of measured quantity: Air humidity |
Comparison with a reference capacitive hygrometer in a climatic chamber | KP02 | |
Reference standards (2)
KP01
KP02