{"lab":{"_id":"6ade8b5cff06824761708156","country":"CZ","accr_number":"2429","accr_body":"ČIA","address":"Květnového vítězství 332/31, Chodov, 149 00 Praha 4","categories":["metrology"],"city":"Praha 4","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.5085025,50.0342572]},"map_coord":[50.0342572,14.5085025],"map_geo":"cai-mapa","methods_count":2,"name":"SPECION, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie temperatury i wilgotności powietrza, w zakresie określonym w załączniku do świadectwa.","search_text":"specion, s.r.o. květnového vítězství 332/31, chodov, 149 00 praha 4 2429","source_page_url":"https://www.cai.cz/?subjekt=2429-specion-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"26-01-2029","website":"www.specion.cz","certificate_date":"26.01.2026","certificate_no":"44/2026","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie temperatury i wilgotności powietrza, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of air temperature and humidity to the extent as specified in the appendix to this Certificate.","zh":"空气温度和湿度领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru teplota a vlhkost vzduchu, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"8a6993494db69310fc6e8c5e45fbcca9923c02d668c6c648b4369bcecf518e0b","source_pdf_url":"https://www.cai.cz/OA/pdf/44_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/44_2026_EN.pdf"},"methods":[{"_id":"c9a23df35cc3135ecc1c9ab1","lab_id":"6ade8b5cff06824761708156","country":"CZ","accr_number":"2429","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące, tory pomiarowe temperatury, w tym termometry komór i szaf cieplnych i klimatycznych, pomiar temperatury w urządzeniach z regulacją temperatury i wilgotności","test_object_en":"Indicating thermometers, temperature measuring chains including thermometers of thermal and climatic chambers and enclosures, measurement of temperature in equipment with temperature and humidity control","test_object_zh":"指示式温度计、温度测量链，包括热工和气候试验箱及柜的温度计，带温湿度调节设备中的温度测量","test_object_cs":"Indikační teploměry, měřicí řetězce teploty včetně teploměrů teplotních a klimatických komor a skříní, měření teploty v zařízeních s regulací teploty a vlhkosti","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -70 °C do -40 °C","cmc":"0,40 °C"},{"name":"","range":"od -40 °C do 100 °C","cmc":"0,35 °C"},{"name":"","range":"od 100 °C do 180 °C","cmc":"0,40 °C"},{"name":"","range":"od 180 °C do 250 °C","cmc":"0,90 °C"}],"parameters_en":[{"name":"","range":"-70 °C to -40 °C","cmc":"0,40 °C"},{"name":"","range":"-40 °C to 100 °C","cmc":"0,35 °C"},{"name":"","range":"100 °C to 180 °C","cmc":"0,40 °C"},{"name":"","range":"180 °C to 250 °C","cmc":"0,90 °C"}],"parameters_zh":[{"name":"","range":"-70 °C 至 -40 °C","cmc":"0,40 °C"},{"name":"","range":"-40 °C 至 100 °C","cmc":"0,35 °C"},{"name":"","range":"100 °C 至 180 °C","cmc":"0,40 °C"},{"name":"","range":"180 °C 至 250 °C","cmc":"0,90 °C"}],"parameters_cs":[{"name":"","range":"-70 °C až -40 °C","cmc":"0,40 °C"},{"name":"","range":"-40 °C až 100 °C","cmc":"0,35 °C"},{"name":"","range":"100 °C až 180 °C","cmc":"0,40 °C"},{"name":"","range":"180 °C až 250 °C","cmc":"0,90 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym w komorze klimatycznej","technique_en":"Comparison with a reference digital thermometer in a climatic chamber","technique_zh":"在气候箱中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v klimatické komoře","techniques":["Porównanie z cyfrowym termometrem wzorcowym w komorze klimatycznej"],"techniques_en":["Comparison with a reference digital thermometer in a climatic chamber"],"techniques_zh":["在气候箱中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -70 °C do -40 °C CMC 0,40 °C\nod -40 °C do 100 °C CMC 0,35 °C\nod 100 °C do 180 °C CMC 0,40 °C\nod 180 °C do 250 °C CMC 0,90 °C\nPorównanie z cyfrowym termometrem wzorcowym w komorze klimatycznej","reference":"KP01","norm_bases":["KP01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące, tory pomiarowe temperatury, w tym termometry komór i szaf cieplnych i klimatycznych, pomiar temperatury w urządzeniach z regulacją temperatury i wilgotności Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym w komorze klimatycznej od -70 °C do -40 °C CMC 0,40 °C od -40 °C do 100 °C CMC 0,35 °C od 100 °C do 180 °C CMC 0,40 °C od 180 °C do 250 °C CMC 0,90 °C Indikační teploměry, měřicí řetězce teploty včetně teploměrů teplotních a klimatických komor a skříní, měření teploty v zařízeních s regulací teploty a vlhkosti Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v klimatické komoře -70 °C až -40 °C CMC 0,40 °C -40 °C až 100 °C CMC 0,35 °C 100 °C až 180 °C CMC 0,40 °C 180 °C až 250 °C CMC 0,90 °C KP01 Termometry wskazujace, tory pomiarowe temperatury, w tym termometry komor i szaf cieplnych i klimatycznych, pomiar temperatury w urzadzeniach z regulacja temperatury i wilgotnosci Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym w komorze klimatycznej od -70 °C do -40 °C CMC 0,40 °C od -40 °C do 100 °C CMC 0,35 °C od 100 °C do 180 °C CMC 0,40 °C od 180 °C do 250 °C CMC 0,90 °C Indikacni teplomery, merici retezce teploty vcetne teplomeru teplotnich a klimatickych komor a skrini, mereni teploty v zarizenich s regulaci teploty a vlhkosti Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v klimaticke komore -70 °C az -40 °C CMC 0,40 °C -40 °C az 100 °C CMC 0,35 °C 100 °C az 180 °C CMC 0,40 °C 180 °C az 250 °C CMC 0,90 °C KP01","search_en":"Indicating thermometers, temperature measuring chains including thermometers of thermal and climatic chambers and enclosures, measurement of temperature in equipment with temperature and humidity control Calibration – temperature Comparison with a reference digital thermometer in a climatic chamber -70 °C to -40 °C CMC 0,40 °C -40 °C to 100 °C CMC 0,35 °C 100 °C to 180 °C CMC 0,40 °C 180 °C to 250 °C CMC 0,90 °C KP01","search_zh":"指示式温度计、温度测量链，包括热工和气候试验箱及柜的温度计，带温湿度调节设备中的温度测量 校准 – 温度 在气候箱中与标准数字温度计比较 -70 °C 至 -40 °C CMC 0,40 °C -40 °C 至 100 °C CMC 0,35 °C 100 °C 至 180 °C CMC 0,40 °C 180 °C 至 250 °C CMC 0,90 °C KP01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8d0f9edd956f4dedd89c8c8a","lab_id":"6ade8b5cff06824761708156","country":"CZ","accr_number":"2429","accr_body":"ČIA","row_label":"1","test_object":"Higrometry powietrza i tory pomiarowe wilgotności, w tym czujniki wilgotności komór i szaf klimatycznych, pomiar wilgotności w urządzeniach z regulacją temperatury i wilgotności","test_object_en":"Air humidity meters and humidity measuring chains, including humidity sensors of climatic chambers and enclosures, measurement of humidity in equipment with temperature and humidity control","test_object_zh":"空气湿度计和湿度测量链，包括气候试验箱及柜的湿度传感器，带温湿度调节设备中的湿度测量","test_object_cs":"Vlhkoměry vzduchu a měřicí řetězce vlhkosti včetně snímačů vlhkosti klimatických komor a skříní, měření vlhkosti v zařízeních s regulací teploty a vlhkosti","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"Temperatura powietrza (15 do 30) °C","range":"od 10 % RH do 50 % RH","cmc":"1,8 % RH"},{"name":"Temperatura powietrza (30 do 60) °C","range":"od 10 % RH do 50 % RH","cmc":"1,9 % RH"},{"name":"Temperatura powietrza (60 do 90) °C","range":"od 10 % RH do 50 % RH","cmc":"2,0 % RH"},{"name":"Temperatura powietrza (15 do 30) °C","range":"od 50 % RH do 90 % RH","cmc":"2,1 % RH"},{"name":"Temperatura powietrza (30 do 60) °C","range":"od 50 % RH do 90 % RH","cmc":"2,3 % RH"},{"name":"Temperatura powietrza (60 do 90) °C","range":"od 50 % RH do 90 % RH","cmc":"2,4 % RH"},{"name":"Temperatura powietrza (15 do 30) °C","range":"od 90 % RH do 95 % RH","cmc":"2,5 % RH"},{"name":"Temperatura powietrza (30 do 60) °C","range":"od 90 % RH do 95 % RH","cmc":"2,5 % RH"},{"name":"Temperatura powietrza (60 do 90) °C","range":"od 90 % RH do 95 % RH","cmc":"2,7 % RH"}],"parameters_en":[{"name":"Air temperature (15 to 30) °C","range":"10 % RH to 50 % RH","cmc":"1,8 % RH"},{"name":"Air temperature (30 to 60) °C","range":"10 % RH to 50 % RH","cmc":"1,9 % RH"},{"name":"Air temperature (60 to 90) °C","range":"10 % RH to 50 % RH","cmc":"2,0 % RH"},{"name":"Air temperature (15 to 30) °C","range":"50 % RH to 90 % RH","cmc":"2,1 % RH"},{"name":"Air temperature (30 to 60) °C","range":"50 % RH to 90 % RH","cmc":"2,3 % RH"},{"name":"Air temperature (60 to 90) °C","range":"50 % RH to 90 % RH","cmc":"2,4 % RH"},{"name":"Air temperature (15 to 30) °C","range":"90 % RH to 95 % RH","cmc":"2,5 % RH"},{"name":"Air temperature (30 to 60) °C","range":"90 % RH to 95 % RH","cmc":"2,5 % RH"},{"name":"Air temperature (60 to 90) °C","range":"90 % RH to 95 % RH","cmc":"2,7 % RH"}],"parameters_zh":[{"name":"空气温度（15 至 30）°C","range":"10 % RH 至 50 % RH","cmc":"1,8 % RH"},{"name":"空气温度（30 至 60）°C","range":"10 % RH 至 50 % RH","cmc":"1,9 % RH"},{"name":"空气温度（60 至 90）°C","range":"10 % RH 至 50 % RH","cmc":"2,0 % RH"},{"name":"空气温度（15 至 30）°C","range":"50 % RH 至 90 % RH","cmc":"2,1 % RH"},{"name":"空气温度（30 至 60）°C","range":"50 % RH 至 90 % RH","cmc":"2,3 % RH"},{"name":"空气温度（60 至 90）°C","range":"50 % RH 至 90 % RH","cmc":"2,4 % RH"},{"name":"空气温度（15 至 30）°C","range":"90 % RH 至 95 % RH","cmc":"2,5 % RH"},{"name":"空气温度（30 至 60）°C","range":"90 % RH 至 95 % RH","cmc":"2,5 % RH"},{"name":"空气温度（60 至 90）°C","range":"90 % RH 至 95 % RH","cmc":"2,7 % RH"}],"parameters_cs":[{"name":"Teplota vzduchu (15 až 30) °C","range":"10 % RH až 50 % RH","cmc":"1,8 % RH"},{"name":"Teplota vzduchu (30 až 60) °C","range":"10 % RH až 50 % RH","cmc":"1,9 % RH"},{"name":"Teplota vzduchu (60 až 90) °C","range":"10 % RH až 50 % RH","cmc":"2,0 % RH"},{"name":"Teplota vzduchu (15 až 30) °C","range":"50 % RH až 90 % RH","cmc":"2,1 % RH"},{"name":"Teplota vzduchu (30 až 60) °C","range":"50 % RH až 90 % RH","cmc":"2,3 % RH"},{"name":"Teplota vzduchu (60 až 90) °C","range":"50 % RH až 90 % RH","cmc":"2,4 % RH"},{"name":"Teplota vzduchu (15 až 30) °C","range":"90 % RH až 95 % RH","cmc":"2,5 % RH"},{"name":"Teplota vzduchu (30 až 60) °C","range":"90 % RH až 95 % RH","cmc":"2,5 % RH"},{"name":"Teplota vzduchu (60 až 90) °C","range":"90 % RH až 95 % RH","cmc":"2,7 % RH"}],"technique":"Porównanie z wzorcowym higrometrem pojemnościowym w komorze klimatycznej","technique_en":"Comparison with a reference capacitive hygrometer in a climatic chamber","technique_zh":"在气候箱中与标准电容式湿度计比较","technique_cs":"Porovnání s etalonovým kapacitním vlhkoměrem v klimatické komoře","techniques":["Porównanie z wzorcowym higrometrem pojemnościowym w komorze klimatycznej"],"techniques_en":["Comparison with a reference capacitive hygrometer in a climatic chamber"],"techniques_zh":["在气候箱中与标准电容式湿度计比较"],"techniques_cs":["Porovnání s etalonovým kapacitním vlhkoměrem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\nTemperatura powietrza (15 do 30) °C od 10 % RH do 50 % RH CMC 1,8 % RH\nTemperatura powietrza (30 do 60) °C od 10 % RH do 50 % RH CMC 1,9 % RH\nTemperatura powietrza (60 do 90) °C od 10 % RH do 50 % RH CMC 2,0 % RH\nTemperatura powietrza (15 do 30) °C od 50 % RH do 90 % RH CMC 2,1 % RH\nTemperatura powietrza (30 do 60) °C od 50 % RH do 90 % RH CMC 2,3 % RH\nTemperatura powietrza (60 do 90) °C od 50 % RH do 90 % RH CMC 2,4 % RH\nTemperatura powietrza (15 do 30) °C od 90 % RH do 95 % RH CMC 2,5 % RH\nTemperatura powietrza (30 do 60) °C od 90 % RH do 95 % RH CMC 2,5 % RH\nTemperatura powietrza (60 do 90) °C od 90 % RH do 95 % RH CMC 2,7 % RH\nPorównanie z wzorcowym higrometrem pojemnościowym w komorze klimatycznej","reference":"KP02","norm_bases":["KP02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Higrometry powietrza i tory pomiarowe wilgotności, w tym czujniki wilgotności komór i szaf klimatycznych, pomiar wilgotności w urządzeniach z regulacją temperatury i wilgotności Wzorcowanie – wilgotność powietrza Porównanie z wzorcowym higrometrem pojemnościowym w komorze klimatycznej Temperatura powietrza (15 do 30) °C od 10 % RH do 50 % RH CMC 1,8 % RH Temperatura powietrza (30 do 60) °C od 10 % RH do 50 % RH CMC 1,9 % RH Temperatura powietrza (60 do 90) °C od 10 % RH do 50 % RH CMC 2,0 % RH Temperatura powietrza (15 do 30) °C od 50 % RH do 90 % RH CMC 2,1 % RH Temperatura powietrza (30 do 60) °C od 50 % RH do 90 % RH CMC 2,3 % RH Temperatura powietrza (60 do 90) °C od 50 % RH do 90 % RH CMC 2,4 % RH Temperatura powietrza (15 do 30) °C od 90 % RH do 95 % RH CMC 2,5 % RH Temperatura powietrza (30 do 60) °C od 90 % RH do 95 % RH CMC 2,5 % RH Temperatura powietrza (60 do 90) °C od 90 % RH do 95 % RH CMC 2,7 % RH Vlhkoměry vzduchu a měřicí řetězce vlhkosti včetně snímačů vlhkosti klimatických komor a skříní, měření vlhkosti v zařízeních s regulací teploty a vlhkosti Kalibrace – vlhkost vzduchu Porovnání s etalonovým kapacitním vlhkoměrem v klimatické komoře Teplota vzduchu (15 až 30) °C 10 % RH až 50 % RH CMC 1,8 % RH Teplota vzduchu (30 až 60) °C 10 % RH až 50 % RH CMC 1,9 % RH Teplota vzduchu (60 až 90) °C 10 % RH až 50 % RH CMC 2,0 % RH Teplota vzduchu (15 až 30) °C 50 % RH až 90 % RH CMC 2,1 % RH Teplota vzduchu (30 až 60) °C 50 % RH až 90 % RH CMC 2,3 % RH Teplota vzduchu (60 až 90) °C 50 % RH až 90 % RH CMC 2,4 % RH Teplota vzduchu (15 až 30) °C 90 % RH až 95 % RH CMC 2,5 % RH Teplota vzduchu (30 až 60) °C 90 % RH až 95 % RH CMC 2,5 % RH Teplota vzduchu (60 až 90) °C 90 % RH až 95 % RH CMC 2,7 % RH KP02 Higrometry powietrza i tory pomiarowe wilgotnosci, w tym czujniki wilgotnosci komor i szaf klimatycznych, pomiar wilgotnosci w urzadzeniach z regulacja temperatury i wilgotnosci Wzorcowanie – wilgotnosc powietrza Porownanie z wzorcowym higrometrem pojemnosciowym w komorze klimatycznej Temperatura powietrza (15 do 30) °C od 10 % RH do 50 % RH CMC 1,8 % RH Temperatura powietrza (30 do 60) °C od 10 % RH do 50 % RH CMC 1,9 % RH Temperatura powietrza (60 do 90) °C od 10 % RH do 50 % RH CMC 2,0 % RH Temperatura powietrza (15 do 30) °C od 50 % RH do 90 % RH CMC 2,1 % RH Temperatura powietrza (30 do 60) °C od 50 % RH do 90 % RH CMC 2,3 % RH Temperatura powietrza (60 do 90) °C od 50 % RH do 90 % RH CMC 2,4 % RH Temperatura powietrza (15 do 30) °C od 90 % RH do 95 % RH CMC 2,5 % RH Temperatura powietrza (30 do 60) °C od 90 % RH do 95 % RH CMC 2,5 % RH Temperatura powietrza (60 do 90) °C od 90 % RH do 95 % RH CMC 2,7 % RH Vlhkomery vzduchu a merici retezce vlhkosti vcetne snimacu vlhkosti klimatickych komor a skrini, mereni vlhkosti v zarizenich s regulaci teploty a vlhkosti Kalibrace – vlhkost vzduchu Porovnani s etalonovym kapacitnim vlhkomerem v klimaticke komore Teplota vzduchu (15 az 30) °C 10 % RH az 50 % RH CMC 1,8 % RH Teplota vzduchu (30 az 60) °C 10 % RH az 50 % RH CMC 1,9 % RH Teplota vzduchu (60 az 90) °C 10 % RH az 50 % RH CMC 2,0 % RH Teplota vzduchu (15 az 30) °C 50 % RH az 90 % RH CMC 2,1 % RH Teplota vzduchu (30 az 60) °C 50 % RH az 90 % RH CMC 2,3 % RH Teplota vzduchu (60 az 90) °C 50 % RH az 90 % RH CMC 2,4 % RH Teplota vzduchu (15 az 30) °C 90 % RH az 95 % RH CMC 2,5 % RH Teplota vzduchu (30 az 60) °C 90 % RH az 95 % RH CMC 2,5 % RH Teplota vzduchu (60 az 90) °C 90 % RH az 95 % RH CMC 2,7 % RH KP02","search_en":"Air humidity meters and humidity measuring chains, including humidity sensors of climatic chambers and enclosures, measurement of humidity in equipment with temperature and humidity control Calibration – air humidity Comparison with a reference capacitive hygrometer in a climatic chamber Air temperature (15 to 30) °C 10 % RH to 50 % RH CMC 1,8 % RH Air temperature (30 to 60) °C 10 % RH to 50 % RH CMC 1,9 % RH Air temperature (60 to 90) °C 10 % RH to 50 % RH CMC 2,0 % RH Air temperature (15 to 30) °C 50 % RH to 90 % RH CMC 2,1 % RH Air temperature (30 to 60) °C 50 % RH to 90 % RH CMC 2,3 % RH Air temperature (60 to 90) °C 50 % RH to 90 % RH CMC 2,4 % RH Air temperature (15 to 30) °C 90 % RH to 95 % RH CMC 2,5 % RH Air temperature (30 to 60) °C 90 % RH to 95 % RH CMC 2,5 % RH Air temperature (60 to 90) °C 90 % RH to 95 % RH CMC 2,7 % RH KP02","search_zh":"空气湿度计和湿度测量链，包括气候试验箱及柜的湿度传感器，带温湿度调节设备中的湿度测量 校准 – 空气湿度 在气候箱中与标准电容式湿度计比较 空气温度（15 至 30）°C 10 % RH 至 50 % RH CMC 1,8 % RH 空气温度（30 至 60）°C 10 % RH 至 50 % RH CMC 1,9 % RH 空气温度（60 至 90）°C 10 % RH 至 50 % RH CMC 2,0 % RH 空气温度（15 至 30）°C 50 % RH 至 90 % RH CMC 2,1 % RH 空气温度（30 至 60）°C 50 % RH 至 90 % RH CMC 2,3 % RH 空气温度（60 至 90）°C 50 % RH 至 90 % RH CMC 2,4 % RH 空气温度（15 至 30）°C 90 % RH 至 95 % RH CMC 2,5 % RH 空气温度（30 至 60）°C 90 % RH 至 95 % RH CMC 2,5 % RH 空气温度（60 至 90）°C 90 % RH 至 95 % RH CMC 2,7 % RH KP02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}