🇨🇿 W-Technika group s.r.o. PL

ČIA 2426 • Praha 6, Czech Republic • 4 calibration items

Metrology & calibration

W-Technika group s.r.o. is a calibration laboratory accredited by ČIA under number 2426 (Praha 6, Czech Republic). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Infrared non-contact thermometers, Thermal cameras. Most frequently used calibration principles: Comparison with a non-contact infrared thermometer, Direct measurement using a black body.

At a glance

  • Accreditation number: ČIA 2426
  • Calibration items in scope: 4
  • Types of calibrated items: 2
  • Calibration principles used: 2
  • City: Praha 6, Czech Republic
  • Valid until: 27-08-2027
Accreditation number
2426
Accreditation body
ČIA
Address
Na okraji 335/42, 162 00 Praha 6 - Veleslavín
City
Praha 6, Czech Republic
Division
Laboratorium wzorcujące
Valid until
27-08-2027

What this laboratory calibrates (2)

Calibration principles (2)

Certificate information

Certificate date
27.08.2024

Accreditation scope — calibration items (4)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Thermal cameras Calibration – temperature
Wavelength (8 – 14) µm — -10 °C to 50 °C · CMC 1,2 °C Wavelength (0,8 – 14) µm — 50 °C to 150 °C · CMC 1,7 °C Wavelength (0,8 – 14) µm — 150 °C to 250 °C · CMC 2,4 °C Wavelength (0,8 – 14) µm — 250 °C to 500 °C · CMC 4,2 °C Wavelength (0,8 – 14) µm — 500 °C to 750 °C · CMC 4,8 °C Wavelength (0,8 – 14) µm — 750 °C to 1000 °C · CMC 7,2 °C
CMC for the field of measured quantity: Temperature
Comparison with a non-contact infrared thermometer KP 01
2 Thermal cameras Calibration – temperature
Wavelength (0,8 – 14) µm — 900 °C to 1150 °C · CMC 8,4 °C Wavelength (0,8 – 14) µm — 1150 °C to 1475 °C · CMC 11,4 °C
CMC for the field of measured quantity: Temperature
Direct measurement using a black body KP 01
3 Infrared non-contact thermometers Calibration – temperature
Wavelength (8 – 14) µm — -10 °C to 50 °C · CMC 1,2 °C Wavelength (0,8 – 14) µm — 50 °C to 150 °C · CMC 1,7 °C Wavelength (0,8 – 14) µm — 150 °C to 250 °C · CMC 2,4 °C Wavelength (0,8 – 14) µm — 250 °C to 500 °C · CMC 4,2 °C Wavelength (0,8 – 14) µm — 500 °C to 750 °C · CMC 4,8 °C Wavelength (0,8 – 14) µm — 750 °C to 1000 °C · CMC 7,2 °C
CMC for the field of measured quantity: Temperature
Comparison with a non-contact infrared thermometer KP 02
4 Infrared non-contact thermometers Calibration – temperature
Wavelength (0,8 – 14) µm; Optics: min. 20:1 — 900 °C to 1150 °C · CMC 8,4 °C Wavelength (0,8 – 14) µm; Optics: min. 20:1 — 1150 °C to 1475 °C · CMC 11,4 °C
CMC for the field of measured quantity: Temperature
Direct measurement using a black body KP 02

Reference standards (2)

KP 01
KP 02

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2426