{"lab":{"_id":"6ade8b5bff06824761708153","accr_number":"2426","country":"CZ","accr_body":"ČIA","address":"Na okraji 335/42, 162 00 Praha 6 - Veleslavín","categories":["metrology"],"city":"Praha 6","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.3420498,50.0891114]},"map_coord":[50.0891114,14.3420498],"map_geo":"cai-mapa","methods_count":4,"name":"W-Technika group s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie temperatury.","search_text":"w-technika group s.r.o. na okraji 335/42, 162 00 praha 6 - veleslavín 2426","source_page_url":"https://www.cai.cz/?subjekt=2426-w-technika-group-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"27-08-2027","website":"www.w-technika.cz","certificate_date":"27.08.2024","certificate_no":"429/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie temperatury.","en":"Calibration in the field of temperature.","zh":"温度领域的校准。","cs":"Kalibrace v oboru teplota."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"b4c6691d75fc0d95ac5b1b7e171be4c973dbc42408a3a0742a4ea7d8cde2b559","source_pdf_url":"https://www.cai.cz/OA/pdf/P429_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P429_2024_EN.pdf"},"methods":[{"_id":"893f2642b3da7d3274f25764","lab_id":"6ade8b5bff06824761708153","country":"CZ","accr_number":"2426","accr_body":"ČIA","row_label":"1","test_object":"Kamery termowizyjne","test_object_en":"Thermal cameras","test_object_zh":"热像仪","test_object_cs":"Termokamery","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Długość fali (8 – 14) µm","range":"od -10 °C do 50 °C","cmc":"1,2 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 50 °C do 150 °C","cmc":"1,7 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 150 °C do 250 °C","cmc":"2,4 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 250 °C do 500 °C","cmc":"4,2 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 500 °C do 750 °C","cmc":"4,8 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 750 °C do 1000 °C","cmc":"7,2 °C"}],"parameters_en":[{"name":"Wavelength (8 – 14) µm","range":"-10 °C to 50 °C","cmc":"1,2 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"50 °C to 150 °C","cmc":"1,7 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"150 °C to 250 °C","cmc":"2,4 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"250 °C to 500 °C","cmc":"4,2 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"500 °C to 750 °C","cmc":"4,8 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"750 °C to 1000 °C","cmc":"7,2 °C"}],"parameters_zh":[{"name":"波长 (8 – 14) µm","range":"-10 °C 至 50 °C","cmc":"1,2 °C"},{"name":"波长 (0,8 – 14) µm","range":"50 °C 至 150 °C","cmc":"1,7 °C"},{"name":"波长 (0,8 – 14) µm","range":"150 °C 至 250 °C","cmc":"2,4 °C"},{"name":"波长 (0,8 – 14) µm","range":"250 °C 至 500 °C","cmc":"4,2 °C"},{"name":"波长 (0,8 – 14) µm","range":"500 °C 至 750 °C","cmc":"4,8 °C"},{"name":"波长 (0,8 – 14) µm","range":"750 °C 至 1000 °C","cmc":"7,2 °C"}],"parameters_cs":[{"name":"Vlnová délka (8 – 14) µm","range":"-10 °C až 50 °C","cmc":"1,2 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"50 °C až 150 °C","cmc":"1,7 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"150 °C až 250 °C","cmc":"2,4 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"250 °C až 500 °C","cmc":"4,2 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"500 °C až 750 °C","cmc":"4,8 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"750 °C až 1000 °C","cmc":"7,2 °C"}],"technique":"Porównanie z bezkontaktowym termometrem na podczerwień","technique_en":"Comparison with a non-contact infrared thermometer","technique_zh":"与非接触式红外温度计比较","technique_cs":"Porovnání s bezdotykovým IČ teploměrem","techniques":["Porównanie z bezkontaktowym termometrem na podczerwień"],"techniques_en":["Comparison with a non-contact infrared thermometer"],"techniques_zh":["与非接触式红外温度计比较"],"techniques_cs":["Porovnání s bezdotykovým IČ teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nDługość fali (8 – 14) µm od -10 °C do 50 °C CMC 1,2 °C\nDługość fali (0,8 – 14) µm od 50 °C do 150 °C CMC 1,7 °C\nDługość fali (0,8 – 14) µm od 150 °C do 250 °C CMC 2,4 °C\nDługość fali (0,8 – 14) µm od 250 °C do 500 °C CMC 4,2 °C\nDługość fali (0,8 – 14) µm od 500 °C do 750 °C CMC 4,8 °C\nDługość fali (0,8 – 14) µm od 750 °C do 1000 °C CMC 7,2 °C\nPorównanie z bezkontaktowym termometrem na podczerwień","reference":"KP 01","norm_bases":["KP 01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kamery termowizyjne Wzorcowanie – temperatura Porównanie z bezkontaktowym termometrem na podczerwień Długość fali (8 – 14) µm od -10 °C do 50 °C CMC 1,2 °C Długość fali (0,8 – 14) µm od 50 °C do 150 °C CMC 1,7 °C Długość fali (0,8 – 14) µm od 150 °C do 250 °C CMC 2,4 °C Długość fali (0,8 – 14) µm od 250 °C do 500 °C CMC 4,2 °C Długość fali (0,8 – 14) µm od 500 °C do 750 °C CMC 4,8 °C Długość fali (0,8 – 14) µm od 750 °C do 1000 °C CMC 7,2 °C Termokamery Kalibrace – teplota Porovnání s bezdotykovým IČ teploměrem Vlnová délka (8 – 14) µm -10 °C až 50 °C CMC 1,2 °C Vlnová délka (0,8 – 14) µm 50 °C až 150 °C CMC 1,7 °C Vlnová délka (0,8 – 14) µm 150 °C až 250 °C CMC 2,4 °C Vlnová délka (0,8 – 14) µm 250 °C až 500 °C CMC 4,2 °C Vlnová délka (0,8 – 14) µm 500 °C až 750 °C CMC 4,8 °C Vlnová délka (0,8 – 14) µm 750 °C až 1000 °C CMC 7,2 °C KP 01 Kamery termowizyjne Wzorcowanie – temperatura Porownanie z bezkontaktowym termometrem na podczerwien Dlugosc fali (8 – 14) µm od -10 °C do 50 °C CMC 1,2 °C Dlugosc fali (0,8 – 14) µm od 50 °C do 150 °C CMC 1,7 °C Dlugosc fali (0,8 – 14) µm od 150 °C do 250 °C CMC 2,4 °C Dlugosc fali (0,8 – 14) µm od 250 °C do 500 °C CMC 4,2 °C Dlugosc fali (0,8 – 14) µm od 500 °C do 750 °C CMC 4,8 °C Dlugosc fali (0,8 – 14) µm od 750 °C do 1000 °C CMC 7,2 °C Termokamery Kalibrace – teplota Porovnani s bezdotykovym IC teplomerem Vlnova delka (8 – 14) µm -10 °C az 50 °C CMC 1,2 °C Vlnova delka (0,8 – 14) µm 50 °C az 150 °C CMC 1,7 °C Vlnova delka (0,8 – 14) µm 150 °C az 250 °C CMC 2,4 °C Vlnova delka (0,8 – 14) µm 250 °C az 500 °C CMC 4,2 °C Vlnova delka (0,8 – 14) µm 500 °C az 750 °C CMC 4,8 °C Vlnova delka (0,8 – 14) µm 750 °C az 1000 °C CMC 7,2 °C KP 01","search_en":"Thermal cameras Calibration – temperature Comparison with a non-contact infrared thermometer Wavelength (8 – 14) µm -10 °C to 50 °C CMC 1,2 °C Wavelength (0,8 – 14) µm 50 °C to 150 °C CMC 1,7 °C Wavelength (0,8 – 14) µm 150 °C to 250 °C CMC 2,4 °C Wavelength (0,8 – 14) µm 250 °C to 500 °C CMC 4,2 °C Wavelength (0,8 – 14) µm 500 °C to 750 °C CMC 4,8 °C Wavelength (0,8 – 14) µm 750 °C to 1000 °C CMC 7,2 °C KP 01","search_zh":"热像仪 校准 – 温度 与非接触式红外温度计比较 波长 (8 – 14) µm -10 °C 至 50 °C CMC 1,2 °C 波长 (0,8 – 14) µm 50 °C 至 150 °C CMC 1,7 °C 波长 (0,8 – 14) µm 150 °C 至 250 °C CMC 2,4 °C 波长 (0,8 – 14) µm 250 °C 至 500 °C CMC 4,2 °C 波长 (0,8 – 14) µm 500 °C 至 750 °C CMC 4,8 °C 波长 (0,8 – 14) µm 750 °C 至 1000 °C CMC 7,2 °C KP 01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"50e66c019385169bda7e05fb","lab_id":"6ade8b5bff06824761708153","country":"CZ","accr_number":"2426","accr_body":"ČIA","row_label":"1","test_object":"Kamery termowizyjne","test_object_en":"Thermal cameras","test_object_zh":"热像仪","test_object_cs":"Termokamery","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Długość fali (0,8 – 14) µm","range":"od 900 °C do 1150 °C","cmc":"8,4 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 1150 °C do 1475 °C","cmc":"11,4 °C"}],"parameters_en":[{"name":"Wavelength (0,8 – 14) µm","range":"900 °C to 1150 °C","cmc":"8,4 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"1150 °C to 1475 °C","cmc":"11,4 °C"}],"parameters_zh":[{"name":"波长 (0,8 – 14) µm","range":"900 °C 至 1150 °C","cmc":"8,4 °C"},{"name":"波长 (0,8 – 14) µm","range":"1150 °C 至 1475 °C","cmc":"11,4 °C"}],"parameters_cs":[{"name":"Vlnová délka (0,8 – 14) µm","range":"900 °C až 1150 °C","cmc":"8,4 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"1150 °C až 1475 °C","cmc":"11,4 °C"}],"technique":"Pomiar bezpośredni za pomocą ciała czarnego","technique_en":"Direct measurement using a black body","technique_zh":"用黑体直接测量","technique_cs":"Přímé měření pomocí černého tělesa","techniques":["Pomiar bezpośredni za pomocą ciała czarnego"],"techniques_en":["Direct measurement using a black body"],"techniques_zh":["用黑体直接测量"],"techniques_cs":["Přímé měření pomocí černého tělesa"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nDługość fali (0,8 – 14) µm od 900 °C do 1150 °C CMC 8,4 °C\nDługość fali (0,8 – 14) µm od 1150 °C do 1475 °C CMC 11,4 °C\nPomiar bezpośredni za pomocą ciała czarnego","reference":"KP 01","norm_bases":["KP 01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kamery termowizyjne Wzorcowanie – temperatura Pomiar bezpośredni za pomocą ciała czarnego Długość fali (0,8 – 14) µm od 900 °C do 1150 °C CMC 8,4 °C Długość fali (0,8 – 14) µm od 1150 °C do 1475 °C CMC 11,4 °C Termokamery Kalibrace – teplota Přímé měření pomocí černého tělesa Vlnová délka (0,8 – 14) µm 900 °C až 1150 °C CMC 8,4 °C Vlnová délka (0,8 – 14) µm 1150 °C až 1475 °C CMC 11,4 °C KP 01 Kamery termowizyjne Wzorcowanie – temperatura Pomiar bezposredni za pomoca ciala czarnego Dlugosc fali (0,8 – 14) µm od 900 °C do 1150 °C CMC 8,4 °C Dlugosc fali (0,8 – 14) µm od 1150 °C do 1475 °C CMC 11,4 °C Termokamery Kalibrace – teplota Prime mereni pomoci cerneho telesa Vlnova delka (0,8 – 14) µm 900 °C az 1150 °C CMC 8,4 °C Vlnova delka (0,8 – 14) µm 1150 °C az 1475 °C CMC 11,4 °C KP 01","search_en":"Thermal cameras Calibration – temperature Direct measurement using a black body Wavelength (0,8 – 14) µm 900 °C to 1150 °C CMC 8,4 °C Wavelength (0,8 – 14) µm 1150 °C to 1475 °C CMC 11,4 °C KP 01","search_zh":"热像仪 校准 – 温度 用黑体直接测量 波长 (0,8 – 14) µm 900 °C 至 1150 °C CMC 8,4 °C 波长 (0,8 – 14) µm 1150 °C 至 1475 °C CMC 11,4 °C KP 01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2fdec77a899b3391f5136142","lab_id":"6ade8b5bff06824761708153","country":"CZ","accr_number":"2426","accr_body":"ČIA","row_label":"2","test_object":"Termometry bezkontaktowe na podczerwień","test_object_en":"Infrared non-contact thermometers","test_object_zh":"红外非接触式温度计","test_object_cs":"Infračervené bezdotykové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Długość fali (8 – 14) µm","range":"od -10 °C do 50 °C","cmc":"1,2 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 50 °C do 150 °C","cmc":"1,7 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 150 °C do 250 °C","cmc":"2,4 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 250 °C do 500 °C","cmc":"4,2 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 500 °C do 750 °C","cmc":"4,8 °C"},{"name":"Długość fali (0,8 – 14) µm","range":"od 750 °C do 1000 °C","cmc":"7,2 °C"}],"parameters_en":[{"name":"Wavelength (8 – 14) µm","range":"-10 °C to 50 °C","cmc":"1,2 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"50 °C to 150 °C","cmc":"1,7 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"150 °C to 250 °C","cmc":"2,4 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"250 °C to 500 °C","cmc":"4,2 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"500 °C to 750 °C","cmc":"4,8 °C"},{"name":"Wavelength (0,8 – 14) µm","range":"750 °C to 1000 °C","cmc":"7,2 °C"}],"parameters_zh":[{"name":"波长 (8 – 14) µm","range":"-10 °C 至 50 °C","cmc":"1,2 °C"},{"name":"波长 (0,8 – 14) µm","range":"50 °C 至 150 °C","cmc":"1,7 °C"},{"name":"波长 (0,8 – 14) µm","range":"150 °C 至 250 °C","cmc":"2,4 °C"},{"name":"波长 (0,8 – 14) µm","range":"250 °C 至 500 °C","cmc":"4,2 °C"},{"name":"波长 (0,8 – 14) µm","range":"500 °C 至 750 °C","cmc":"4,8 °C"},{"name":"波长 (0,8 – 14) µm","range":"750 °C 至 1000 °C","cmc":"7,2 °C"}],"parameters_cs":[{"name":"Vlnová délka (8 – 14) µm","range":"-10 °C až 50 °C","cmc":"1,2 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"50 °C až 150 °C","cmc":"1,7 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"150 °C až 250 °C","cmc":"2,4 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"250 °C až 500 °C","cmc":"4,2 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"500 °C až 750 °C","cmc":"4,8 °C"},{"name":"Vlnová délka (0,8 – 14) µm","range":"750 °C až 1000 °C","cmc":"7,2 °C"}],"technique":"Porównanie z bezkontaktowym termometrem na podczerwień","technique_en":"Comparison with a non-contact infrared thermometer","technique_zh":"与非接触式红外温度计比较","technique_cs":"Porovnání s bezdotykovým IČ teploměrem","techniques":["Porównanie z bezkontaktowym termometrem na podczerwień"],"techniques_en":["Comparison with a non-contact infrared thermometer"],"techniques_zh":["与非接触式红外温度计比较"],"techniques_cs":["Porovnání s bezdotykovým IČ teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nDługość fali (8 – 14) µm od -10 °C do 50 °C CMC 1,2 °C\nDługość fali (0,8 – 14) µm od 50 °C do 150 °C CMC 1,7 °C\nDługość fali (0,8 – 14) µm od 150 °C do 250 °C CMC 2,4 °C\nDługość fali (0,8 – 14) µm od 250 °C do 500 °C CMC 4,2 °C\nDługość fali (0,8 – 14) µm od 500 °C do 750 °C CMC 4,8 °C\nDługość fali (0,8 – 14) µm od 750 °C do 1000 °C CMC 7,2 °C\nPorównanie z bezkontaktowym termometrem na podczerwień","reference":"KP 02","norm_bases":["KP 02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezkontaktowe na podczerwień Wzorcowanie – temperatura Porównanie z bezkontaktowym termometrem na podczerwień Długość fali (8 – 14) µm od -10 °C do 50 °C CMC 1,2 °C Długość fali (0,8 – 14) µm od 50 °C do 150 °C CMC 1,7 °C Długość fali (0,8 – 14) µm od 150 °C do 250 °C CMC 2,4 °C Długość fali (0,8 – 14) µm od 250 °C do 500 °C CMC 4,2 °C Długość fali (0,8 – 14) µm od 500 °C do 750 °C CMC 4,8 °C Długość fali (0,8 – 14) µm od 750 °C do 1000 °C CMC 7,2 °C Infračervené bezdotykové teploměry Kalibrace – teplota Porovnání s bezdotykovým IČ teploměrem Vlnová délka (8 – 14) µm -10 °C až 50 °C CMC 1,2 °C Vlnová délka (0,8 – 14) µm 50 °C až 150 °C CMC 1,7 °C Vlnová délka (0,8 – 14) µm 150 °C až 250 °C CMC 2,4 °C Vlnová délka (0,8 – 14) µm 250 °C až 500 °C CMC 4,2 °C Vlnová délka (0,8 – 14) µm 500 °C až 750 °C CMC 4,8 °C Vlnová délka (0,8 – 14) µm 750 °C až 1000 °C CMC 7,2 °C KP 02 Termometry bezkontaktowe na podczerwien Wzorcowanie – temperatura Porownanie z bezkontaktowym termometrem na podczerwien Dlugosc fali (8 – 14) µm od -10 °C do 50 °C CMC 1,2 °C Dlugosc fali (0,8 – 14) µm od 50 °C do 150 °C CMC 1,7 °C Dlugosc fali (0,8 – 14) µm od 150 °C do 250 °C CMC 2,4 °C Dlugosc fali (0,8 – 14) µm od 250 °C do 500 °C CMC 4,2 °C Dlugosc fali (0,8 – 14) µm od 500 °C do 750 °C CMC 4,8 °C Dlugosc fali (0,8 – 14) µm od 750 °C do 1000 °C CMC 7,2 °C Infracervene bezdotykove teplomery Kalibrace – teplota Porovnani s bezdotykovym IC teplomerem Vlnova delka (8 – 14) µm -10 °C az 50 °C CMC 1,2 °C Vlnova delka (0,8 – 14) µm 50 °C az 150 °C CMC 1,7 °C Vlnova delka (0,8 – 14) µm 150 °C az 250 °C CMC 2,4 °C Vlnova delka (0,8 – 14) µm 250 °C az 500 °C CMC 4,2 °C Vlnova delka (0,8 – 14) µm 500 °C az 750 °C CMC 4,8 °C Vlnova delka (0,8 – 14) µm 750 °C az 1000 °C CMC 7,2 °C KP 02","search_en":"Infrared non-contact thermometers Calibration – temperature Comparison with a non-contact infrared thermometer Wavelength (8 – 14) µm -10 °C to 50 °C CMC 1,2 °C Wavelength (0,8 – 14) µm 50 °C to 150 °C CMC 1,7 °C Wavelength (0,8 – 14) µm 150 °C to 250 °C CMC 2,4 °C Wavelength (0,8 – 14) µm 250 °C to 500 °C CMC 4,2 °C Wavelength (0,8 – 14) µm 500 °C to 750 °C CMC 4,8 °C Wavelength (0,8 – 14) µm 750 °C to 1000 °C CMC 7,2 °C KP 02","search_zh":"红外非接触式温度计 校准 – 温度 与非接触式红外温度计比较 波长 (8 – 14) µm -10 °C 至 50 °C CMC 1,2 °C 波长 (0,8 – 14) µm 50 °C 至 150 °C CMC 1,7 °C 波长 (0,8 – 14) µm 150 °C 至 250 °C CMC 2,4 °C 波长 (0,8 – 14) µm 250 °C 至 500 °C CMC 4,2 °C 波长 (0,8 – 14) µm 500 °C 至 750 °C CMC 4,8 °C 波长 (0,8 – 14) µm 750 °C 至 1000 °C CMC 7,2 °C KP 02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9fe6eef6cfd6388703a858bc","lab_id":"6ade8b5bff06824761708153","country":"CZ","accr_number":"2426","accr_body":"ČIA","row_label":"2","test_object":"Termometry bezkontaktowe na podczerwień","test_object_en":"Infrared non-contact thermometers","test_object_zh":"红外非接触式温度计","test_object_cs":"Infračervené bezdotykové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Długość fali (0,8 – 14) µm; Optyka: min. 20:1","range":"od 900 °C do 1150 °C","cmc":"8,4 °C"},{"name":"Długość fali (0,8 – 14) µm; Optyka: min. 20:1","range":"od 1150 °C do 1475 °C","cmc":"11,4 °C"}],"parameters_en":[{"name":"Wavelength (0,8 – 14) µm; Optics: min. 20:1","range":"900 °C to 1150 °C","cmc":"8,4 °C"},{"name":"Wavelength (0,8 – 14) µm; Optics: min. 20:1","range":"1150 °C to 1475 °C","cmc":"11,4 °C"}],"parameters_zh":[{"name":"波长 (0,8 – 14) µm；光学：最小 20:1","range":"900 °C 至 1150 °C","cmc":"8,4 °C"},{"name":"波长 (0,8 – 14) µm；光学：最小 20:1","range":"1150 °C 至 1475 °C","cmc":"11,4 °C"}],"parameters_cs":[{"name":"Vlnová délka (0,8 – 14) µm; Optika: min. 20:1","range":"900 °C až 1150 °C","cmc":"8,4 °C"},{"name":"Vlnová délka (0,8 – 14) µm; Optika: min. 20:1","range":"1150 °C až 1475 °C","cmc":"11,4 °C"}],"technique":"Pomiar bezpośredni za pomocą ciała czarnego","technique_en":"Direct measurement using a black body","technique_zh":"用黑体直接测量","technique_cs":"Přímé měření pomocí černého tělesa","techniques":["Pomiar bezpośredni za pomocą ciała czarnego"],"techniques_en":["Direct measurement using a black body"],"techniques_zh":["用黑体直接测量"],"techniques_cs":["Přímé měření pomocí černého tělesa"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nDługość fali (0,8 – 14) µm; Optyka: min. 20:1 od 900 °C do 1150 °C CMC 8,4 °C\nDługość fali (0,8 – 14) µm; Optyka: min. 20:1 od 1150 °C do 1475 °C CMC 11,4 °C\nPomiar bezpośredni za pomocą ciała czarnego","reference":"KP 02","norm_bases":["KP 02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezkontaktowe na podczerwień Wzorcowanie – temperatura Pomiar bezpośredni za pomocą ciała czarnego Długość fali (0,8 – 14) µm; Optyka: min. 20:1 od 900 °C do 1150 °C CMC 8,4 °C Długość fali (0,8 – 14) µm; Optyka: min. 20:1 od 1150 °C do 1475 °C CMC 11,4 °C Infračervené bezdotykové teploměry Kalibrace – teplota Přímé měření pomocí černého tělesa Vlnová délka (0,8 – 14) µm; Optika: min. 20:1 900 °C až 1150 °C CMC 8,4 °C Vlnová délka (0,8 – 14) µm; Optika: min. 20:1 1150 °C až 1475 °C CMC 11,4 °C KP 02 Termometry bezkontaktowe na podczerwien Wzorcowanie – temperatura Pomiar bezposredni za pomoca ciala czarnego Dlugosc fali (0,8 – 14) µm; Optyka: min. 20:1 od 900 °C do 1150 °C CMC 8,4 °C Dlugosc fali (0,8 – 14) µm; Optyka: min. 20:1 od 1150 °C do 1475 °C CMC 11,4 °C Infracervene bezdotykove teplomery Kalibrace – teplota Prime mereni pomoci cerneho telesa Vlnova delka (0,8 – 14) µm; Optika: min. 20:1 900 °C az 1150 °C CMC 8,4 °C Vlnova delka (0,8 – 14) µm; Optika: min. 20:1 1150 °C az 1475 °C CMC 11,4 °C KP 02","search_en":"Infrared non-contact thermometers Calibration – temperature Direct measurement using a black body Wavelength (0,8 – 14) µm; Optics: min. 20:1 900 °C to 1150 °C CMC 8,4 °C Wavelength (0,8 – 14) µm; Optics: min. 20:1 1150 °C to 1475 °C CMC 11,4 °C KP 02","search_zh":"红外非接触式温度计 校准 – 温度 用黑体直接测量 波长 (0,8 – 14) µm；光学：最小 20:1 900 °C 至 1150 °C CMC 8,4 °C 波长 (0,8 – 14) µm；光学：最小 20:1 1150 °C 至 1475 °C CMC 11,4 °C KP 02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}