🇨🇿 ABB s.r.o. PL
Metrology & calibration
ABB s.r.o. is a calibration laboratory accredited by ČIA under number 2423 (Brno, Czech Republic). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: AC current ratio / Measuring current transformers, AC voltage ratio / Measuring voltage transformers, Current phase shift / Measuring current transformers, Voltage phase shift / Measuring voltage transformers. Most frequently used calibration principles: Comparison with a standard measuring transformer.
At a glance
- Accreditation number: ČIA 2423
- Calibration items in scope: 4
- Types of calibrated items: 4
- Calibration principles used: 1
- City: Brno, Czech Republic
- Valid until: 22-05-2031
- Accreditation number
- 2423
- Accreditation body
- ČIA
- Address
- Vídeňská 100/117, 619 00 Brno
- City
- Brno, Czech Republic
- Division
- Laboratorium wzorcujące przekładników pomiarowych
- Valid until
- 22-05-2031
What this laboratory calibrates (4)
- AC current ratio / Measuring current transformers — 1 calibration item
- AC voltage ratio / Measuring voltage transformers — 1 calibration item
- Current phase shift / Measuring current transformers — 1 calibration item
- Voltage phase shift / Measuring voltage transformers — 1 calibration item
Calibration principles (1)
- Comparison with a standard measuring transformer — 4 calibration items
Certificate information
- Certificate date
- 22.05.2026
Accreditation scope — calibration items (4)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | AC current ratio / Measuring current transformers | Calibration – electrical quantities 5 A to 40 000 A / 5 A and 1 A; 50 Hz — 1 to 40 000 · CMC 0,015 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard measuring transformer | 1VLD261300, čl. 5.2.1 | |
| 2 | Current phase shift / Measuring current transformers | Calibration – electrical quantities 5 A to 40 000 A / 5 A and 1 A; 50 Hz — -600' to 600' · CMC 0,75' CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard measuring transformer | 1VLD261300, čl. 5.2.1 | |
| 3 | AC voltage ratio / Measuring voltage transformers | Calibration – electrical quantities 1 kV to 36 kV / 100/√3 V to 120 V; 50 Hz — 0,008 to 624 · CMC 0,018 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard measuring transformer | 1VLD261300, čl. 5.2.2 | |
| 4 | Voltage phase shift / Measuring voltage transformers | Calibration – electrical quantities 1 kV to 36 kV / 100/√3 V to 120 V; 50 Hz — -600' to 600' · CMC 0,90' CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard measuring transformer | 1VLD261300, čl. 5.2.2 | |
Reference standards (2)
1VLD261300, čl. 5.2.1
1VLD261300, čl. 5.2.2