🇨🇿 TECHNICKÉ SLUŽBY OCHRANY OVZDUŠÍ OSTRAVA spol. s r.o. PL
Metrology & calibration
TECHNICKÉ SLUŽBY OCHRANY OVZDUŠÍ OSTRAVA spol. s r.o. is a calibration laboratory accredited by ČIA under number 2420 (Ostrava, Czech Republic). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Amount-of-substance concentration, Amount-of-substance concentration of tracer gas C₃H₈ / olfactometers, NO₂ – NO converter efficiency, Volumetric gas flow / automated measuring systems. Most frequently used calibration principles: Calculated from the gas flow velocity determined by direct measurem…, Comparison with reference gas (ČSN EN ISO 9169, ČSN ISO 11095), Direct measurement of the physical realization of the unit (ČSN EN….
At a glance
- Accreditation number: ČIA 2420
- Calibration items in scope: 4
- Types of calibrated items: 4
- Calibration principles used: 4
- City: Ostrava, Czech Republic
- Valid until: 13-11-2030
- Accreditation number
- 2420
- Accreditation body
- ČIA
- Address
- Janáčkova 1020/7, Moravská Ostrava, 702 00 Ostrava
- City
- Ostrava, Czech Republic
- Division
- Laboratorium wzorcujące
- Valid until
- 13-11-2030
What this laboratory calibrates (4)
- Amount-of-substance concentration — 1 calibration item
- Amount-of-substance concentration of tracer gas C₃H₈ / olfactometers — 1 calibration item
- NO₂ – NO converter efficiency — 1 calibration item
- Volumetric gas flow / automated measuring systems — 1 calibration item
Calibration principles (4)
- Calculated from the gas flow velocity determined by direct measurement with a Prandtl tube — 1 calibration item
- Comparison with reference gas (ČSN EN ISO 9169, ČSN ISO 11095) — 1 calibration item
- Direct measurement of the physical realization of the unit (ČSN EN 13725, chap. 6, 7, Annex B) — 1 calibration item
- Direct measurement of the physical realization of the unit (ČSN EN 14792) — 1 calibration item
Certificate information
- Certificate date
- 13.11.2025
Accreditation scope — calibration items (4)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Volumetric gas flow / automated measuring systems | Calibration – flow Gas flow velocity: 5 m·s⁻¹ to 50 m·s⁻¹ — 600 m³ h⁻¹ to 300000 m³ h⁻¹ · CMC 3,0 % CMC for the field of measured quantity: Flow |
Calculated from the gas flow velocity determined by direct measurement with a Prandtl tube | SOP_10 | |
| 2 | Amount-of-substance concentration | Calibration – amount of substance SO₂ analyzers — 0 µmol/mol to 18 µmol/mol · CMC 0,12 µmol/mol SO₂ analyzers — 18 µmol/mol to 5000 µmol/mol · CMC 0,66 % NO analyzers — 0 µmol/mol to 24 µmol/mol · CMC 0,12 µmol/mol NO analyzers — 24 µmol/mol to 3000 µmol/mol · CMC 0,5 % CO analyzers — 0 µmol/mol to 17 µmol/mol · CMC 0,12 µmol/mol CO analyzers — 17 µmol/mol to 10000 µmol/mol · CMC 0,66 µmol/mol C₃H₈ analyzers — 0 µmol/mol to 36 µmol/mol · CMC 0,11 µmol/mol C₃H₈ analyzers — 36 µmol/mol to 5000 µmol/mol · CMC 0,3 % CH₄ analyzers — 0 µmol/mol to 36 µmol/mol · CMC 0,11 µmol/mol CH₄ analyzers — 36 µmol/mol to 40000 µmol/mol · CMC 0,3 % NH₃ analyzers — 0 µmol/mol to 4 µmol/mol · CMC 0,12 µmol/mol NH₃ analyzers — 4 µmol/mol to 2000 µmol/mol · CMC 3,0 % NO₂ analyzers — 0 µmol/mol to 2 µmol/mol · CMC 0,12 µmol/mol NO₂ analyzers — 2 µmol/mol to 2000 µmol/mol · CMC 6,0 % N₂O analyzers — 0 µmol/mol to 6 µmol/mol · CMC 0,12 µmol/mol N₂O analyzers — 6 µmol/mol to 2000 µmol/mol · CMC 2,0 % CO₂ analyzers — 0 mol/mol to 0,004 mol/mol · CMC 0,01 mmol/mol CO₂ analyzers — 0,004 mol/mol to 0,5 mol/mol · CMC 0,3 % O₂ analyzers — 0 mol/mol to 0,003 mol/mol · CMC 0,01 mmol/mol O₂ analyzers — 0,004 mol/mol to 0,25 mol/mol · CMC 0,42 % CMC for the field of measured quantity: Amount of substance |
Comparison with reference gas (ČSN EN ISO 9169, ČSN ISO 11095) | SOP_22 | |
| 3 | NO₂ – NO converter efficiency | Calibration – amount of substance 50 to 500 µmol/mol — 0 % to 100 % · CMC 0,4 % abs. CMC for the field of measured quantity: Amount of substance |
Direct measurement of the physical realization of the unit (ČSN EN 14792) | SOP_23 | |
| 4 | Amount-of-substance concentration of tracer gas C₃H₈ / olfactometers | Calibration – amount of substance 1 µmol/mol to 100 mmol/mol · CMC 0,5 % CMC for the field of measured quantity: Amount of substance |
Direct measurement of the physical realization of the unit (ČSN EN 13725, chap. 6, 7, Annex B) | SOP_24 | |
Reference standards (4)
SOP_10
SOP_22
SOP_23
SOP_24