{"lab":{"_id":"6ade8b58ff0682476170814e","country":"CZ","accr_number":"2420","accr_body":"ČIA","address":"Janáčkova 1020/7, Moravská Ostrava, 702 00 Ostrava","categories":["metrology"],"city":"Ostrava","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[18.2842984,49.8369161]},"map_coord":[49.8369161,18.2842984],"map_geo":"cai-mapa","methods_count":4,"name":"TECHNICKÉ SLUŽBY OCHRANY OVZDUŠÍ OSTRAVA spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: przepływ i ilość substancji, w zakresie określonym w załączniku do świadectwa.","search_text":"technické služby ochrany ovzduší ostrava spol. s r.o. janáčkova 1020/7, moravská ostrava, 702 00 ostrava 2420","source_page_url":"https://www.cai.cz/?subjekt=2420-technicke-sluzby-ochrany-ovzdusi-ostrava-spol-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"13-11-2030","website":"www.teso-ostrava.cz","certificate_date":"13.11.2025","certificate_no":"582/2025","certificate_replaces":"556/2022 z 21.11.2022","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: przepływ i ilość substancji, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the fields of flow and amount of substance to the extent as specified in the appendix to this Certificate.","zh":"流量和物质的量领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech průtok a látkové množství, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników wzorcowań.","en":"The laboratory provides opinions and interpretations of the calibration results.","zh":"实验室提供校准结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků kalibrací."}],"source_lang":"cs","source_pdf_sha256":"ff66250a19c412919521762b4056fa6d6dd7a4474017d0382a1a2b4d8d77d983","source_pdf_url":"https://www.cai.cz/OA/pdf/582_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/582_2025_EN.pdf"},"methods":[{"_id":"227fd42975bd88a5858edd6e","lab_id":"6ade8b58ff0682476170814e","country":"CZ","accr_number":"2420","accr_body":"ČIA","row_label":"1","test_object":"Objętościowy przepływ gazu / automatyczne systemy pomiarowe","test_object_en":"Volumetric gas flow / automated measuring systems","test_object_zh":"气体体积流量 / 自动测量系统","test_object_cs":"Objemový průtok plynu / automatizované měřicí systémy","methodology":"Wzorcowanie – przepływ","methodology_en":"Calibration – flow","methodology_zh":"校准 – 流量","methodology_cs":"Kalibrace – průtok","parameters":[{"name":"Prędkość przepływu gazu: 5 m·s⁻¹ do 50 m·s⁻¹","range":"od 600 m³ h⁻¹ do 300000 m³ h⁻¹","cmc":"3,0 %"}],"parameters_en":[{"name":"Gas flow velocity: 5 m·s⁻¹ to 50 m·s⁻¹","range":"600 m³ h⁻¹ to 300000 m³ h⁻¹","cmc":"3,0 %"}],"parameters_zh":[{"name":"气体流速：5 m·s⁻¹ 至 50 m·s⁻¹","range":"600 m³ h⁻¹ 至 300000 m³ h⁻¹","cmc":"3,0 %"}],"parameters_cs":[{"name":"Rychlost proudění plynu: 5 m·s⁻¹ až 50 m·s⁻¹","range":"600 m³ h⁻¹ až 300000 m³ h⁻¹","cmc":"3,0 %"}],"technique":"Obliczeniowo z prędkości przepływu gazu wyznaczonej bezpośrednim pomiarem rurką Prandtla","technique_en":"Calculated from the gas flow velocity determined by direct measurement with a Prandtl tube","technique_zh":"由普朗特管直接测量的气体流速计算","technique_cs":"Výpočtem z rychlosti proudění plynu stanovené přímým měřením Prandtlovou trubicí","techniques":["Obliczeniowo z prędkości przepływu gazu wyznaczonej bezpośrednim pomiarem rurką Prandtla"],"techniques_en":["Calculated from the gas flow velocity determined by direct measurement with a Prandtl tube"],"techniques_zh":["由普朗特管直接测量的气体流速计算"],"techniques_cs":["Výpočtem z rychlosti proudění plynu stanovené přímým měřením Prandtlovou trubicí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – przepływ\nPrędkość przepływu gazu: 5 m·s⁻¹ do 50 m·s⁻¹ od 600 m³ h⁻¹ do 300000 m³ h⁻¹ CMC 3,0 %\nObliczeniowo z prędkości przepływu gazu wyznaczonej bezpośrednim pomiarem rurką Prandtla","reference":"SOP_10","norm_bases":["SOP_10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: przepływ","regulatory_area_en":"CMC for the field of measured quantity: Flow","regulatory_area_zh":"被测量领域的CMC：流量","regulatory_area_cs":"CMC pro obor měřené veličiny: Průtok","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Objętościowy przepływ gazu / automatyczne systemy pomiarowe Wzorcowanie – przepływ Obliczeniowo z prędkości przepływu gazu wyznaczonej bezpośrednim pomiarem rurką Prandtla Prędkość przepływu gazu: 5 m·s⁻¹ do 50 m·s⁻¹ od 600 m³ h⁻¹ do 300000 m³ h⁻¹ CMC 3,0 % Objemový průtok plynu / automatizované měřicí systémy Kalibrace – průtok Výpočtem z rychlosti proudění plynu stanovené přímým měřením Prandtlovou trubicí Rychlost proudění plynu: 5 m·s⁻¹ až 50 m·s⁻¹ 600 m³ h⁻¹ až 300000 m³ h⁻¹ CMC 3,0 % SOP_10 Objetosciowy przeplyw gazu / automatyczne systemy pomiarowe Wzorcowanie – przeplyw Obliczeniowo z predkosci przeplywu gazu wyznaczonej bezposrednim pomiarem rurka Prandtla Predkosc przeplywu gazu: 5 m·s⁻¹ do 50 m·s⁻¹ od 600 m³ h⁻¹ do 300000 m³ h⁻¹ CMC 3,0 % Objemovy prutok plynu / automatizovane merici systemy Kalibrace – prutok Vypoctem z rychlosti proudeni plynu stanovene primym merenim Prandtlovou trubici Rychlost proudeni plynu: 5 m·s⁻¹ az 50 m·s⁻¹ 600 m³ h⁻¹ az 300000 m³ h⁻¹ CMC 3,0 % SOP_10","search_en":"Volumetric gas flow / automated measuring systems Calibration – flow Calculated from the gas flow velocity determined by direct measurement with a Prandtl tube Gas flow velocity: 5 m·s⁻¹ to 50 m·s⁻¹ 600 m³ h⁻¹ to 300000 m³ h⁻¹ CMC 3,0 % SOP_10","search_zh":"气体体积流量 / 自动测量系统 校准 – 流量 由普朗特管直接测量的气体流速计算 气体流速：5 m·s⁻¹ 至 50 m·s⁻¹ 600 m³ h⁻¹ 至 300000 m³ h⁻¹ CMC 3,0 % SOP_10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"70e8d2788664f65a18b1cf09","lab_id":"6ade8b58ff0682476170814e","country":"CZ","accr_number":"2420","accr_body":"ČIA","row_label":"1","test_object":"Stężenie ilości substancji","test_object_en":"Amount-of-substance concentration","test_object_zh":"物质的量浓度","test_object_cs":"Látková koncentrace","methodology":"Wzorcowanie – ilość substancji","methodology_en":"Calibration – amount of substance","methodology_zh":"校准 – 物质的量","methodology_cs":"Kalibrace – látkové množství","parameters":[{"name":"analizatory SO₂","range":"od 0 µmol/mol do 18 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analizatory SO₂","range":"od 18 µmol/mol do 5000 µmol/mol","cmc":"0,66 %"},{"name":"analizatory NO","range":"od 0 µmol/mol do 24 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analizatory NO","range":"od 24 µmol/mol do 3000 µmol/mol","cmc":"0,5 %"},{"name":"analizatory CO","range":"od 0 µmol/mol do 17 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analizatory CO","range":"od 17 µmol/mol do 10000 µmol/mol","cmc":"0,66 µmol/mol"},{"name":"analizatory C₃H₈","range":"od 0 µmol/mol do 36 µmol/mol","cmc":"0,11 µmol/mol"},{"name":"analizatory C₃H₈","range":"od 36 µmol/mol do 5000 µmol/mol","cmc":"0,3 %"},{"name":"analizatory CH₄","range":"od 0 µmol/mol do 36 µmol/mol","cmc":"0,11 µmol/mol"},{"name":"analizatory CH₄","range":"od 36 µmol/mol do 40000 µmol/mol","cmc":"0,3 %"},{"name":"analizatory NH₃","range":"od 0 µmol/mol do 4 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analizatory NH₃","range":"od 4 µmol/mol do 2000 µmol/mol","cmc":"3,0 %"},{"name":"analizatory NO₂","range":"od 0 µmol/mol do 2 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analizatory NO₂","range":"od 2 µmol/mol do 2000 µmol/mol","cmc":"6,0 %"},{"name":"analizatory N₂O","range":"od 0 µmol/mol do 6 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analizatory N₂O","range":"od 6 µmol/mol do 2000 µmol/mol","cmc":"2,0 %"},{"name":"analizatory CO₂","range":"od 0 mol/mol do 0,004 mol/mol","cmc":"0,01 mmol/mol"},{"name":"analizatory CO₂","range":"od 0,004 mol/mol do 0,5 mol/mol","cmc":"0,3 %"},{"name":"analizatory O₂","range":"od 0 mol/mol do 0,003 mol/mol","cmc":"0,01 mmol/mol"},{"name":"analizatory O₂","range":"od 0,004 mol/mol do 0,25 mol/mol","cmc":"0,42 %"}],"parameters_en":[{"name":"SO₂ analyzers","range":"0 µmol/mol to 18 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"SO₂ analyzers","range":"18 µmol/mol to 5000 µmol/mol","cmc":"0,66 %"},{"name":"NO analyzers","range":"0 µmol/mol to 24 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"NO analyzers","range":"24 µmol/mol to 3000 µmol/mol","cmc":"0,5 %"},{"name":"CO analyzers","range":"0 µmol/mol to 17 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"CO analyzers","range":"17 µmol/mol to 10000 µmol/mol","cmc":"0,66 µmol/mol"},{"name":"C₃H₈ analyzers","range":"0 µmol/mol to 36 µmol/mol","cmc":"0,11 µmol/mol"},{"name":"C₃H₈ analyzers","range":"36 µmol/mol to 5000 µmol/mol","cmc":"0,3 %"},{"name":"CH₄ analyzers","range":"0 µmol/mol to 36 µmol/mol","cmc":"0,11 µmol/mol"},{"name":"CH₄ analyzers","range":"36 µmol/mol to 40000 µmol/mol","cmc":"0,3 %"},{"name":"NH₃ analyzers","range":"0 µmol/mol to 4 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"NH₃ analyzers","range":"4 µmol/mol to 2000 µmol/mol","cmc":"3,0 %"},{"name":"NO₂ analyzers","range":"0 µmol/mol to 2 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"NO₂ analyzers","range":"2 µmol/mol to 2000 µmol/mol","cmc":"6,0 %"},{"name":"N₂O analyzers","range":"0 µmol/mol to 6 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"N₂O analyzers","range":"6 µmol/mol to 2000 µmol/mol","cmc":"2,0 %"},{"name":"CO₂ analyzers","range":"0 mol/mol to 0,004 mol/mol","cmc":"0,01 mmol/mol"},{"name":"CO₂ analyzers","range":"0,004 mol/mol to 0,5 mol/mol","cmc":"0,3 %"},{"name":"O₂ analyzers","range":"0 mol/mol to 0,003 mol/mol","cmc":"0,01 mmol/mol"},{"name":"O₂ analyzers","range":"0,004 mol/mol to 0,25 mol/mol","cmc":"0,42 %"}],"parameters_zh":[{"name":"二氧化硫 SO₂ 分析仪","range":"0 µmol/mol 至 18 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"二氧化硫 SO₂ 分析仪","range":"18 µmol/mol 至 5000 µmol/mol","cmc":"0,66 %"},{"name":"一氧化氮 NO 分析仪","range":"0 µmol/mol 至 24 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"一氧化氮 NO 分析仪","range":"24 µmol/mol 至 3000 µmol/mol","cmc":"0,5 %"},{"name":"一氧化碳 CO 分析仪","range":"0 µmol/mol 至 17 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"一氧化碳 CO 分析仪","range":"17 µmol/mol 至 10000 µmol/mol","cmc":"0,66 µmol/mol"},{"name":"丙烷 C₃H₈ 分析仪","range":"0 µmol/mol 至 36 µmol/mol","cmc":"0,11 µmol/mol"},{"name":"丙烷 C₃H₈ 分析仪","range":"36 µmol/mol 至 5000 µmol/mol","cmc":"0,3 %"},{"name":"甲烷 CH₄ 分析仪","range":"0 µmol/mol 至 36 µmol/mol","cmc":"0,11 µmol/mol"},{"name":"甲烷 CH₄ 分析仪","range":"36 µmol/mol 至 40000 µmol/mol","cmc":"0,3 %"},{"name":"氨 NH₃ 分析仪","range":"0 µmol/mol 至 4 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"氨 NH₃ 分析仪","range":"4 µmol/mol 至 2000 µmol/mol","cmc":"3,0 %"},{"name":"二氧化氮 NO₂ 分析仪","range":"0 µmol/mol 至 2 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"二氧化氮 NO₂ 分析仪","range":"2 µmol/mol 至 2000 µmol/mol","cmc":"6,0 %"},{"name":"一氧化二氮 N₂O 分析仪","range":"0 µmol/mol 至 6 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"一氧化二氮 N₂O 分析仪","range":"6 µmol/mol 至 2000 µmol/mol","cmc":"2,0 %"},{"name":"二氧化碳 CO₂ 分析仪","range":"0 mol/mol 至 0,004 mol/mol","cmc":"0,01 mmol/mol"},{"name":"二氧化碳 CO₂ 分析仪","range":"0,004 mol/mol 至 0,5 mol/mol","cmc":"0,3 %"},{"name":"氧 O₂ 分析仪","range":"0 mol/mol 至 0,003 mol/mol","cmc":"0,01 mmol/mol"},{"name":"氧 O₂ 分析仪","range":"0,004 mol/mol 至 0,25 mol/mol","cmc":"0,42 %"}],"parameters_cs":[{"name":"analyzátory SO₂","range":"0 µmol/mol až 18 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analyzátory SO₂","range":"18 µmol/mol až 5000 µmol/mol","cmc":"0,66 %"},{"name":"analyzátory NO","range":"0 µmol/mol až 24 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analyzátory NO","range":"24 µmol/mol až 3000 µmol/mol","cmc":"0,5 %"},{"name":"analyzátory CO","range":"0 µmol/mol až 17 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analyzátory CO","range":"17 µmol/mol až 10000 µmol/mol","cmc":"0,66 µmol/mol"},{"name":"analyzátory C₃H₈","range":"0 µmol/mol až 36 µmol/mol","cmc":"0,11 µmol/mol"},{"name":"analyzátory C₃H₈","range":"36 µmol/mol až 5000 µmol/mol","cmc":"0,3 %"},{"name":"analyzátory CH₄","range":"0 µmol/mol až 36 µmol/mol","cmc":"0,11 µmol/mol"},{"name":"analyzátory CH₄","range":"36 µmol/mol až 40000 µmol/mol","cmc":"0,3 %"},{"name":"analyzátory NH₃","range":"0 µmol/mol až 4 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analyzátory NH₃","range":"4 µmol/mol až 2000 µmol/mol","cmc":"3,0 %"},{"name":"analyzátory NO₂","range":"0 µmol/mol až 2 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analyzátory NO₂","range":"2 µmol/mol až 2000 µmol/mol","cmc":"6,0 %"},{"name":"analyzátory N₂O","range":"0 µmol/mol až 6 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"analyzátory N₂O","range":"6 µmol/mol až 2000 µmol/mol","cmc":"2,0 %"},{"name":"analyzátory CO₂","range":"0 mol/mol až 0,004 mol/mol","cmc":"0,01 mmol/mol"},{"name":"analyzátory CO₂","range":"0,004 mol/mol až 0,5 mol/mol","cmc":"0,3 %"},{"name":"analyzátory O₂","range":"0 mol/mol až 0,003 mol/mol","cmc":"0,01 mmol/mol"},{"name":"analyzátory O₂","range":"0,004 mol/mol až 0,25 mol/mol","cmc":"0,42 %"}],"technique":"Porównanie z wzorcem gazowym (ČSN EN ISO 9169, ČSN ISO 11095)","technique_en":"Comparison with reference gas (ČSN EN ISO 9169, ČSN ISO 11095)","technique_zh":"与气体标准比较（ČSN EN ISO 9169、ČSN ISO 11095）","technique_cs":"Porovnání s plynným standardem (ČSN EN ISO 9169, ČSN ISO 11095)","techniques":["Porównanie z wzorcem gazowym (ČSN EN ISO 9169, ČSN ISO 11095)"],"techniques_en":["Comparison with reference gas (ČSN EN ISO 9169, ČSN ISO 11095)"],"techniques_zh":["与气体标准比较（ČSN EN ISO 9169、ČSN ISO 11095）"],"techniques_cs":["Porovnání s plynným standardem (ČSN EN ISO 9169, ČSN ISO 11095)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ilość substancji\nZakres:\nanalizatory SO₂ od 0 µmol/mol do 18 µmol/mol CMC 0,12 µmol/mol\nanalizatory SO₂ od 18 µmol/mol do 5000 µmol/mol CMC 0,66 %\nanalizatory NO od 0 µmol/mol do 24 µmol/mol CMC 0,12 µmol/mol\nanalizatory NO od 24 µmol/mol do 3000 µmol/mol CMC 0,5 %\nanalizatory CO od 0 µmol/mol do 17 µmol/mol CMC 0,12 µmol/mol\nanalizatory CO od 17 µmol/mol do 10000 µmol/mol CMC 0,66 µmol/mol\nanalizatory C₃H₈ od 0 µmol/mol do 36 µmol/mol CMC 0,11 µmol/mol\nanalizatory C₃H₈ od 36 µmol/mol do 5000 µmol/mol CMC 0,3 %\nanalizatory CH₄ od 0 µmol/mol do 36 µmol/mol CMC 0,11 µmol/mol\nanalizatory CH₄ od 36 µmol/mol do 40000 µmol/mol CMC 0,3 %\nanalizatory NH₃ od 0 µmol/mol do 4 µmol/mol CMC 0,12 µmol/mol\nanalizatory NH₃ od 4 µmol/mol do 2000 µmol/mol CMC 3,0 %\nanalizatory NO₂ od 0 µmol/mol do 2 µmol/mol CMC 0,12 µmol/mol\nanalizatory NO₂ od 2 µmol/mol do 2000 µmol/mol CMC 6,0 %\nanalizatory N₂O od 0 µmol/mol do 6 µmol/mol CMC 0,12 µmol/mol\nanalizatory N₂O od 6 µmol/mol do 2000 µmol/mol CMC 2,0 %\nanalizatory CO₂ od 0 mol/mol do 0,004 mol/mol CMC 0,01 mmol/mol\nanalizatory CO₂ od 0,004 mol/mol do 0,5 mol/mol CMC 0,3 %\nanalizatory O₂ od 0 mol/mol do 0,003 mol/mol CMC 0,01 mmol/mol\nanalizatory O₂ od 0,004 mol/mol do 0,25 mol/mol CMC 0,42 %\nPorównanie z wzorcem gazowym (ČSN EN ISO 9169, ČSN ISO 11095)","reference":"SOP_22","norm_bases":["SOP_22"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ilość substancji","regulatory_area_en":"CMC for the field of measured quantity: Amount of substance","regulatory_area_zh":"被测量领域的CMC：物质的量","regulatory_area_cs":"CMC pro obor měřené veličiny: Látkové množství","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stężenie ilości substancji Wzorcowanie – ilość substancji Porównanie z wzorcem gazowym (ČSN EN ISO 9169, ČSN ISO 11095) analizatory SO₂ od 0 µmol/mol do 18 µmol/mol CMC 0,12 µmol/mol analizatory SO₂ od 18 µmol/mol do 5000 µmol/mol CMC 0,66 % analizatory NO od 0 µmol/mol do 24 µmol/mol CMC 0,12 µmol/mol analizatory NO od 24 µmol/mol do 3000 µmol/mol CMC 0,5 % analizatory CO od 0 µmol/mol do 17 µmol/mol CMC 0,12 µmol/mol analizatory CO od 17 µmol/mol do 10000 µmol/mol CMC 0,66 µmol/mol analizatory C₃H₈ od 0 µmol/mol do 36 µmol/mol CMC 0,11 µmol/mol analizatory C₃H₈ od 36 µmol/mol do 5000 µmol/mol CMC 0,3 % analizatory CH₄ od 0 µmol/mol do 36 µmol/mol CMC 0,11 µmol/mol analizatory CH₄ od 36 µmol/mol do 40000 µmol/mol CMC 0,3 % analizatory NH₃ od 0 µmol/mol do 4 µmol/mol CMC 0,12 µmol/mol analizatory NH₃ od 4 µmol/mol do 2000 µmol/mol CMC 3,0 % analizatory NO₂ od 0 µmol/mol do 2 µmol/mol CMC 0,12 µmol/mol analizatory NO₂ od 2 µmol/mol do 2000 µmol/mol CMC 6,0 % analizatory N₂O od 0 µmol/mol do 6 µmol/mol CMC 0,12 µmol/mol analizatory N₂O od 6 µmol/mol do 2000 µmol/mol CMC 2,0 % analizatory CO₂ od 0 mol/mol do 0,004 mol/mol CMC 0,01 mmol/mol analizatory CO₂ od 0,004 mol/mol do 0,5 mol/mol CMC 0,3 % analizatory O₂ od 0 mol/mol do 0,003 mol/mol CMC 0,01 mmol/mol analizatory O₂ od 0,004 mol/mol do 0,25 mol/mol CMC 0,42 % Látková koncentrace Kalibrace – látkové množství Porovnání s plynným standardem (ČSN EN ISO 9169, ČSN ISO 11095) analyzátory SO₂ 0 µmol/mol až 18 µmol/mol CMC 0,12 µmol/mol analyzátory SO₂ 18 µmol/mol až 5000 µmol/mol CMC 0,66 % analyzátory NO 0 µmol/mol až 24 µmol/mol CMC 0,12 µmol/mol analyzátory NO 24 µmol/mol až 3000 µmol/mol CMC 0,5 % analyzátory CO 0 µmol/mol až 17 µmol/mol CMC 0,12 µmol/mol analyzátory CO 17 µmol/mol až 10000 µmol/mol CMC 0,66 µmol/mol analyzátory C₃H₈ 0 µmol/mol až 36 µmol/mol CMC 0,11 µmol/mol analyzátory C₃H₈ 36 µmol/mol až 5000 µmol/mol CMC 0,3 % analyzátory CH₄ 0 µmol/mol až 36 µmol/mol CMC 0,11 µmol/mol analyzátory CH₄ 36 µmol/mol až 40000 µmol/mol CMC 0,3 % analyzátory NH₃ 0 µmol/mol až 4 µmol/mol CMC 0,12 µmol/mol analyzátory NH₃ 4 µmol/mol až 2000 µmol/mol CMC 3,0 % analyzátory NO₂ 0 µmol/mol až 2 µmol/mol CMC 0,12 µmol/mol analyzátory NO₂ 2 µmol/mol až 2000 µmol/mol CMC 6,0 % analyzátory N₂O 0 µmol/mol až 6 µmol/mol CMC 0,12 µmol/mol analyzátory N₂O 6 µmol/mol až 2000 µmol/mol CMC 2,0 % analyzátory CO₂ 0 mol/mol až 0,004 mol/mol CMC 0,01 mmol/mol analyzátory CO₂ 0,004 mol/mol až 0,5 mol/mol CMC 0,3 % analyzátory O₂ 0 mol/mol až 0,003 mol/mol CMC 0,01 mmol/mol analyzátory O₂ 0,004 mol/mol až 0,25 mol/mol CMC 0,42 % SOP_22 Stezenie ilosci substancji Wzorcowanie – ilosc substancji Porownanie z wzorcem gazowym (CSN EN ISO 9169, CSN ISO 11095) analizatory SO₂ od 0 µmol/mol do 18 µmol/mol CMC 0,12 µmol/mol analizatory SO₂ od 18 µmol/mol do 5000 µmol/mol CMC 0,66 % analizatory NO od 0 µmol/mol do 24 µmol/mol CMC 0,12 µmol/mol analizatory NO od 24 µmol/mol do 3000 µmol/mol CMC 0,5 % analizatory CO od 0 µmol/mol do 17 µmol/mol CMC 0,12 µmol/mol analizatory CO od 17 µmol/mol do 10000 µmol/mol CMC 0,66 µmol/mol analizatory C₃H₈ od 0 µmol/mol do 36 µmol/mol CMC 0,11 µmol/mol analizatory C₃H₈ od 36 µmol/mol do 5000 µmol/mol CMC 0,3 % analizatory CH₄ od 0 µmol/mol do 36 µmol/mol CMC 0,11 µmol/mol analizatory CH₄ od 36 µmol/mol do 40000 µmol/mol CMC 0,3 % analizatory NH₃ od 0 µmol/mol do 4 µmol/mol CMC 0,12 µmol/mol analizatory NH₃ od 4 µmol/mol do 2000 µmol/mol CMC 3,0 % analizatory NO₂ od 0 µmol/mol do 2 µmol/mol CMC 0,12 µmol/mol analizatory NO₂ od 2 µmol/mol do 2000 µmol/mol CMC 6,0 % analizatory N₂O od 0 µmol/mol do 6 µmol/mol CMC 0,12 µmol/mol analizatory N₂O od 6 µmol/mol do 2000 µmol/mol CMC 2,0 % analizatory CO₂ od 0 mol/mol do 0,004 mol/mol CMC 0,01 mmol/mol analizatory CO₂ od 0,004 mol/mol do 0,5 mol/mol CMC 0,3 % analizatory O₂ od 0 mol/mol do 0,003 mol/mol CMC 0,01 mmol/mol analizatory O₂ od 0,004 mol/mol do 0,25 mol/mol CMC 0,42 % Latkova koncentrace Kalibrace – latkove mnozstvi Porovnani s plynnym standardem (CSN EN ISO 9169, CSN ISO 11095) analyzatory SO₂ 0 µmol/mol az 18 µmol/mol CMC 0,12 µmol/mol analyzatory SO₂ 18 µmol/mol az 5000 µmol/mol CMC 0,66 % analyzatory NO 0 µmol/mol az 24 µmol/mol CMC 0,12 µmol/mol analyzatory NO 24 µmol/mol az 3000 µmol/mol CMC 0,5 % analyzatory CO 0 µmol/mol az 17 µmol/mol CMC 0,12 µmol/mol analyzatory CO 17 µmol/mol az 10000 µmol/mol CMC 0,66 µmol/mol analyzatory C₃H₈ 0 µmol/mol az 36 µmol/mol CMC 0,11 µmol/mol analyzatory C₃H₈ 36 µmol/mol az 5000 µmol/mol CMC 0,3 % analyzatory CH₄ 0 µmol/mol az 36 µmol/mol CMC 0,11 µmol/mol analyzatory CH₄ 36 µmol/mol az 40000 µmol/mol CMC 0,3 % analyzatory NH₃ 0 µmol/mol az 4 µmol/mol CMC 0,12 µmol/mol analyzatory NH₃ 4 µmol/mol az 2000 µmol/mol CMC 3,0 % analyzatory NO₂ 0 µmol/mol az 2 µmol/mol CMC 0,12 µmol/mol analyzatory NO₂ 2 µmol/mol az 2000 µmol/mol CMC 6,0 % analyzatory N₂O 0 µmol/mol az 6 µmol/mol CMC 0,12 µmol/mol analyzatory N₂O 6 µmol/mol az 2000 µmol/mol CMC 2,0 % analyzatory CO₂ 0 mol/mol az 0,004 mol/mol CMC 0,01 mmol/mol analyzatory CO₂ 0,004 mol/mol az 0,5 mol/mol CMC 0,3 % analyzatory O₂ 0 mol/mol az 0,003 mol/mol CMC 0,01 mmol/mol analyzatory O₂ 0,004 mol/mol az 0,25 mol/mol CMC 0,42 % SOP_22","search_en":"Amount-of-substance concentration Calibration – amount of substance Comparison with reference gas (ČSN EN ISO 9169, ČSN ISO 11095) SO₂ analyzers 0 µmol/mol to 18 µmol/mol CMC 0,12 µmol/mol SO₂ analyzers 18 µmol/mol to 5000 µmol/mol CMC 0,66 % NO analyzers 0 µmol/mol to 24 µmol/mol CMC 0,12 µmol/mol NO analyzers 24 µmol/mol to 3000 µmol/mol CMC 0,5 % CO analyzers 0 µmol/mol to 17 µmol/mol CMC 0,12 µmol/mol CO analyzers 17 µmol/mol to 10000 µmol/mol CMC 0,66 µmol/mol C₃H₈ analyzers 0 µmol/mol to 36 µmol/mol CMC 0,11 µmol/mol C₃H₈ analyzers 36 µmol/mol to 5000 µmol/mol CMC 0,3 % CH₄ analyzers 0 µmol/mol to 36 µmol/mol CMC 0,11 µmol/mol CH₄ analyzers 36 µmol/mol to 40000 µmol/mol CMC 0,3 % NH₃ analyzers 0 µmol/mol to 4 µmol/mol CMC 0,12 µmol/mol NH₃ analyzers 4 µmol/mol to 2000 µmol/mol CMC 3,0 % NO₂ analyzers 0 µmol/mol to 2 µmol/mol CMC 0,12 µmol/mol NO₂ analyzers 2 µmol/mol to 2000 µmol/mol CMC 6,0 % N₂O analyzers 0 µmol/mol to 6 µmol/mol CMC 0,12 µmol/mol N₂O analyzers 6 µmol/mol to 2000 µmol/mol CMC 2,0 % CO₂ analyzers 0 mol/mol to 0,004 mol/mol CMC 0,01 mmol/mol CO₂ analyzers 0,004 mol/mol to 0,5 mol/mol CMC 0,3 % O₂ analyzers 0 mol/mol to 0,003 mol/mol CMC 0,01 mmol/mol O₂ analyzers 0,004 mol/mol to 0,25 mol/mol CMC 0,42 % SOP_22","search_zh":"物质的量浓度 校准 – 物质的量 与气体标准比较（ČSN EN ISO 9169、ČSN ISO 11095） 二氧化硫 SO₂ 分析仪 0 µmol/mol 至 18 µmol/mol CMC 0,12 µmol/mol 二氧化硫 SO₂ 分析仪 18 µmol/mol 至 5000 µmol/mol CMC 0,66 % 一氧化氮 NO 分析仪 0 µmol/mol 至 24 µmol/mol CMC 0,12 µmol/mol 一氧化氮 NO 分析仪 24 µmol/mol 至 3000 µmol/mol CMC 0,5 % 一氧化碳 CO 分析仪 0 µmol/mol 至 17 µmol/mol CMC 0,12 µmol/mol 一氧化碳 CO 分析仪 17 µmol/mol 至 10000 µmol/mol CMC 0,66 µmol/mol 丙烷 C₃H₈ 分析仪 0 µmol/mol 至 36 µmol/mol CMC 0,11 µmol/mol 丙烷 C₃H₈ 分析仪 36 µmol/mol 至 5000 µmol/mol CMC 0,3 % 甲烷 CH₄ 分析仪 0 µmol/mol 至 36 µmol/mol CMC 0,11 µmol/mol 甲烷 CH₄ 分析仪 36 µmol/mol 至 40000 µmol/mol CMC 0,3 % 氨 NH₃ 分析仪 0 µmol/mol 至 4 µmol/mol CMC 0,12 µmol/mol 氨 NH₃ 分析仪 4 µmol/mol 至 2000 µmol/mol CMC 3,0 % 二氧化氮 NO₂ 分析仪 0 µmol/mol 至 2 µmol/mol CMC 0,12 µmol/mol 二氧化氮 NO₂ 分析仪 2 µmol/mol 至 2000 µmol/mol CMC 6,0 % 一氧化二氮 N₂O 分析仪 0 µmol/mol 至 6 µmol/mol CMC 0,12 µmol/mol 一氧化二氮 N₂O 分析仪 6 µmol/mol 至 2000 µmol/mol CMC 2,0 % 二氧化碳 CO₂ 分析仪 0 mol/mol 至 0,004 mol/mol CMC 0,01 mmol/mol 二氧化碳 CO₂ 分析仪 0,004 mol/mol 至 0,5 mol/mol CMC 0,3 % 氧 O₂ 分析仪 0 mol/mol 至 0,003 mol/mol CMC 0,01 mmol/mol 氧 O₂ 分析仪 0,004 mol/mol 至 0,25 mol/mol CMC 0,42 % SOP_22","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"98062b05f812c092fb79a53f","lab_id":"6ade8b58ff0682476170814e","country":"CZ","accr_number":"2420","accr_body":"ČIA","row_label":"2","test_object":"Sprawność konwertera NO₂-NO","test_object_en":"NO₂ – NO converter efficiency","test_object_zh":"NO₂-NO 转换器效率","test_object_cs":"Účinnost konvertoru NO₂-NO","methodology":"Wzorcowanie – ilość substancji","methodology_en":"Calibration – amount of substance","methodology_zh":"校准 – 物质的量","methodology_cs":"Kalibrace – látkové množství","parameters":[{"name":"50 do 500 µmol/mol","range":"od 0 % do 100 %","cmc":"0,4 % abs."}],"parameters_en":[{"name":"50 to 500 µmol/mol","range":"0 % to 100 %","cmc":"0,4 % abs."}],"parameters_zh":[{"name":"50 至 500 µmol/mol","range":"0 % 至 100 %","cmc":"0,4 % abs."}],"parameters_cs":[{"name":"50 až 500 µmol/mol","range":"0 % až 100 %","cmc":"0,4 % abs."}],"technique":"Pomiar bezpośredni fizycznej realizacji jednostki (ČSN EN 14792)","technique_en":"Direct measurement of the physical realization of the unit (ČSN EN 14792)","technique_zh":"直接测量单位的物理复现（ČSN EN 14792）","technique_cs":"Přímé měření fyzikální realizace jednotky (ČSN EN 14792)","techniques":["Pomiar bezpośredni fizycznej realizacji jednostki (ČSN EN 14792)"],"techniques_en":["Direct measurement of the physical realization of the unit (ČSN EN 14792)"],"techniques_zh":["直接测量单位的物理复现（ČSN EN 14792）"],"techniques_cs":["Přímé měření fyzikální realizace jednotky (ČSN EN 14792)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ilość substancji\n50 do 500 µmol/mol od 0 % do 100 % CMC 0,4 % abs.\nPomiar bezpośredni fizycznej realizacji jednostki (ČSN EN 14792)","reference":"SOP_23","norm_bases":["SOP_23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ilość substancji","regulatory_area_en":"CMC for the field of measured quantity: Amount of substance","regulatory_area_zh":"被测量领域的CMC：物质的量","regulatory_area_cs":"CMC pro obor měřené veličiny: Látkové množství","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawność konwertera NO₂-NO Wzorcowanie – ilość substancji Pomiar bezpośredni fizycznej realizacji jednostki (ČSN EN 14792) 50 do 500 µmol/mol od 0 % do 100 % CMC 0,4 % abs. Účinnost konvertoru NO₂-NO Kalibrace – látkové množství Přímé měření fyzikální realizace jednotky (ČSN EN 14792) 50 až 500 µmol/mol 0 % až 100 % CMC 0,4 % abs. SOP_23 Sprawnosc konwertera NO₂-NO Wzorcowanie – ilosc substancji Pomiar bezposredni fizycznej realizacji jednostki (CSN EN 14792) 50 do 500 µmol/mol od 0 % do 100 % CMC 0,4 % abs. Ucinnost konvertoru NO₂-NO Kalibrace – latkove mnozstvi Prime mereni fyzikalni realizace jednotky (CSN EN 14792) 50 az 500 µmol/mol 0 % az 100 % CMC 0,4 % abs. SOP_23","search_en":"NO₂ – NO converter efficiency Calibration – amount of substance Direct measurement of the physical realization of the unit (ČSN EN 14792) 50 to 500 µmol/mol 0 % to 100 % CMC 0,4 % abs. SOP_23","search_zh":"NO₂-NO 转换器效率 校准 – 物质的量 直接测量单位的物理复现（ČSN EN 14792） 50 至 500 µmol/mol 0 % 至 100 % CMC 0,4 % abs. SOP_23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"503e01a85ed3a941841e0cf8","lab_id":"6ade8b58ff0682476170814e","country":"CZ","accr_number":"2420","accr_body":"ČIA","row_label":"3","test_object":"Stężenie ilości substancji gazu znacznikowego C₃H₈ / olfaktometry","test_object_en":"Amount-of-substance concentration of tracer gas C₃H₈ / olfactometers","test_object_zh":"示踪气体 C₃H₈ 的物质的量浓度 / 嗅觉测量仪","test_object_cs":"Látková koncentrace značkovacího plynu C₃H₈ / olfaktometry","methodology":"Wzorcowanie – ilość substancji","methodology_en":"Calibration – amount of substance","methodology_zh":"校准 – 物质的量","methodology_cs":"Kalibrace – látkové množství","parameters":[{"name":"","range":"od 1 µmol/mol do 100 mmol/mol","cmc":"0,5 %"}],"parameters_en":[{"name":"","range":"1 µmol/mol to 100 mmol/mol","cmc":"0,5 %"}],"parameters_zh":[{"name":"","range":"1 µmol/mol 至 100 mmol/mol","cmc":"0,5 %"}],"parameters_cs":[{"name":"","range":"1 µmol/mol až 100 mmol/mol","cmc":"0,5 %"}],"technique":"Pomiar bezpośredni fizycznej realizacji jednostki (ČSN EN 13725, rozdz. 6, 7, załącznik B)","technique_en":"Direct measurement of the physical realization of the unit (ČSN EN 13725, chap. 6, 7, Annex B)","technique_zh":"直接测量单位的物理复现（ČSN EN 13725，第 6、7 章，附录 B）","technique_cs":"Přímé měření fyzikální realizace jednotky (ČSN EN 13725, kap. 6, 7, příloha B)","techniques":["Pomiar bezpośredni fizycznej realizacji jednostki (ČSN EN 13725, rozdz. 6, 7, załącznik B)"],"techniques_en":["Direct measurement of the physical realization of the unit (ČSN EN 13725, chap. 6, 7, Annex B)"],"techniques_zh":["直接测量单位的物理复现（ČSN EN 13725，第 6、7 章，附录 B）"],"techniques_cs":["Přímé měření fyzikální realizace jednotky (ČSN EN 13725, kap. 6, 7, příloha B)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ilość substancji\nod 1 µmol/mol do 100 mmol/mol CMC 0,5 %\nPomiar bezpośredni fizycznej realizacji jednostki (ČSN EN 13725, rozdz. 6, 7, załącznik B)","reference":"SOP_24","norm_bases":["SOP_24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ilość substancji","regulatory_area_en":"CMC for the field of measured quantity: Amount of substance","regulatory_area_zh":"被测量领域的CMC：物质的量","regulatory_area_cs":"CMC pro obor měřené veličiny: Látkové množství","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stężenie ilości substancji gazu znacznikowego C₃H₈ / olfaktometry Wzorcowanie – ilość substancji Pomiar bezpośredni fizycznej realizacji jednostki (ČSN EN 13725, rozdz. 6, 7, załącznik B) od 1 µmol/mol do 100 mmol/mol CMC 0,5 % Látková koncentrace značkovacího plynu C₃H₈ / olfaktometry Kalibrace – látkové množství Přímé měření fyzikální realizace jednotky (ČSN EN 13725, kap. 6, 7, příloha B) 1 µmol/mol až 100 mmol/mol CMC 0,5 % SOP_24 Stezenie ilosci substancji gazu znacznikowego C₃H₈ / olfaktometry Wzorcowanie – ilosc substancji Pomiar bezposredni fizycznej realizacji jednostki (CSN EN 13725, rozdz. 6, 7, zalacznik B) od 1 µmol/mol do 100 mmol/mol CMC 0,5 % Latkova koncentrace znackovaciho plynu C₃H₈ / olfaktometry Kalibrace – latkove mnozstvi Prime mereni fyzikalni realizace jednotky (CSN EN 13725, kap. 6, 7, priloha B) 1 µmol/mol az 100 mmol/mol CMC 0,5 % SOP_24","search_en":"Amount-of-substance concentration of tracer gas C₃H₈ / olfactometers Calibration – amount of substance Direct measurement of the physical realization of the unit (ČSN EN 13725, chap. 6, 7, Annex B) 1 µmol/mol to 100 mmol/mol CMC 0,5 % SOP_24","search_zh":"示踪气体 C₃H₈ 的物质的量浓度 / 嗅觉测量仪 校准 – 物质的量 直接测量单位的物理复现（ČSN EN 13725，第 6、7 章，附录 B） 1 µmol/mol 至 100 mmol/mol CMC 0,5 % SOP_24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}