🇨🇿 TERMOLAB, spol. s r.o. PL

ČIA 2409 • Brno, Czech Republic • 12 calibration items

Metrology & calibration

TERMOLAB, spol. s r.o. is a calibration laboratory accredited by ČIA under number 2409 (Brno, Czech Republic). Its accreditation scope covers 12 calibration items in the following areas: Metrology & calibration. Calibrated items include: Indicating thermometers, temperature measuring chains, dataloggers, Thermoelectric temperature sensors, Measuring chains – simulation of the electrical input signal, Non-contact infrared thermometers. Most frequently used calibration principles: Comparison with a standard thermometer, Comparison with a standard thermometer in a furnace with a liquid m…, Comparison with a standard thermometer in a horizontal furnace.

At a glance

  • Accreditation number: ČIA 2409
  • Calibration items in scope: 12
  • Types of calibrated items: 6
  • Calibration principles used: 8
  • City: Brno, Czech Republic
  • Valid until: 05-05-2028
Accreditation number
2409
Accreditation body
ČIA
Address
Kraví hora 1000/8, Veveří, 602 00 Brno
City
Brno, Czech Republic
Division
Laboratorium wzorcujące
Valid until
05-05-2028

What this laboratory calibrates (6)

Calibration principles (8)

Certificate information

Certificate date
09.09.2026

Accreditation scope — calibration items (12)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Non-contact infrared thermometers Calibration – temperature
50 °C to 500 °C · CMC 3,0 °C 700 °C to 1200 °C · CMC 9,0 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer 02_KPIR
2 Thermoelectric temperature sensors Calibration – temperature
0 °C to 50 °C · CMC 1,5 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a furnace with a liquid medium 02_KPN
3 Thermoelectric temperature sensors Calibration – temperature
50 °C to 200 °C · CMC 1,3 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a liquid bath / horizontal furnace 02_KPN
4 Thermoelectric temperature sensors Calibration – temperature
200 °C to 400 °C · CMC 1,7 °C 400 °C to 600 °C · CMC 1,8 °C 600 °C to 700 °C · CMC 3,6 °C 700 °C to 900 °C · CMC 4,8 °C 900 °C to 1200 °C · CMC 6,0 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a horizontal furnace 02_KPN
5 Measuring chains – simulation of the electrical input signal Calibration – temperature
Thermocouples type K — -100 °C to 1370 °C · CMC 0,6 °C Thermocouples type N — -100 °C to 1300 °C · CMC 0,9 °C Thermocouples type S — -50 °C to 1760 °C · CMC 1,1 °C Thermocouples type R — -50 °C to 1760 °C · CMC 0,8 °C Thermocouples type J — -100 °C to 1200 °C · CMC 0,6 °C Thermocouples type T — -100 °C to 400 °C · CMC 0,6 °C Resistance thermometers Pt100 — -200 °C to 200 °C · CMC 0,2 °C Resistance thermometers Pt100 — 200 °C to 850 °C · CMC 0,3 °C
CMC for the field of measured quantity: Temperature
Direct measurement of the reference calibrator signal 02_KPR
6 Measuring chains – simulation of the electrical input signal Calibration – temperature
Current output of the transmitter — -200 °C to -50 °C · CMC 0,2 °C Current output of the transmitter — -50 °C to 50 °C · CMC 0,1 °C Current output of the transmitter — 50 °C to 200 °C · CMC 0,2 °C Current output of the transmitter — 200 °C to 400 °C · CMC 0,3 °C Current output of the transmitter — 400 °C to 600 °C · CMC 0,5 °C
CMC for the field of measured quantity: Temperature
Comparison with a process calibrator 02_KPR
7 Indicating thermometers, temperature measuring chains, dataloggers Calibration – temperature
-30 °C to 5 °C · CMC 0,4 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a furnace with a liquid medium 02_KPP
8 Indicating thermometers, temperature measuring chains, dataloggers Calibration – temperature
0 °C · CMC 0,1 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer 02_KPP
9 Indicating thermometers, temperature measuring chains, dataloggers Calibration – temperature
5 °C to 150 °C · CMC 0,15 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a liquid bath 02_KPP
10 Indicating thermometers, temperature measuring chains, dataloggers Calibration – temperature
150 °C to 200 °C · CMC 0,4 °C 200 °C to 400 °C · CMC 1,1 °C 400 °C to 600 °C · CMC 2,1 °C 600 °C to 900 °C · CMC 4,8 °C 900 °C to 1200 °C · CMC 6,0 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a horizontal furnace 02_KPP
11 Temperature equipment with temperature control Calibration – temperature
-30 °C to 150 °C · CMC 0,6 °C 150 °C to 500 °C · CMC 3,0 °C 500 °C to 900 °C · CMC 5,3 °C 900 °C to 1200 °C · CMC 6,5 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer 02_KPP
12 Relative humidity / calibration of humidity control chains Calibration – humidity
(10 to 23) °C — 20 % RH to 90 % RH · CMC 5 % RH (23 to 35) °C — 10 % RH to 90 % RH · CMC 5 % RH
CMC for the field of measured quantity: Humidity
Comparison with a standard hygrometer 02_KPV

Reference standards (5)

02_KPIR
02_KPN
02_KPP
02_KPR
02_KPV