{"lab":{"_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","address":"Kraví hora 1000/8, Veveří, 602 00 Brno","categories":["metrology"],"city":"Brno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.586098,49.2031646]},"map_coord":[49.2031646,16.586098],"map_geo":"cai-mapa","methods_count":12,"name":"TERMOLAB, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie temperatury i wilgotności, w zakresie określonym w załączniku do świadectwa.","search_text":"termolab, spol. s r.o. kraví hora 1000/8, veveří, 602 00 brno 2409","source_page_url":"https://www.cai.cz/?subjekt=2409-termolab-spol-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"05-05-2028","website":"www.termolab.cz","certificate_date":"09.09.2026","certificate_no":"425/2026","certificate_replaces":"546/2024 z 11.10.2024","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie temperatury i wilgotności, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of temperature and humidity, as specified in the appendix to this certificate.","zh":"温度和湿度领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru teplota a vlhkost, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"RH","pl":"wilgotność względna","en":"relative humidity","zh":"相对湿度","cs":"relativní vlhkost"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"24553dba7022cb2f95a38c22434563c2eb8e9fde86716500d1f84ff4ba018a05","source_pdf_url":"https://www.cai.cz/OA/pdf/425_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"27f82554cf08e628fe05067e","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"1","test_object":"Bezkontaktowe termometry na podczerwień","test_object_en":"Non-contact infrared thermometers","test_object_zh":"非接触式红外温度计","test_object_cs":"Bezdotykové infračervené teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 50 °C do 500 °C","cmc":"3,0 °C"},{"name":"","range":"od 700 °C do 1200 °C","cmc":"9,0 °C"}],"parameters_en":[{"name":"","range":"50 °C to 500 °C","cmc":"3,0 °C"},{"name":"","range":"700 °C to 1200 °C","cmc":"9,0 °C"}],"parameters_zh":[{"name":"","range":"50 °C 至 500 °C","cmc":"3,0 °C"},{"name":"","range":"700 °C 至 1200 °C","cmc":"9,0 °C"}],"parameters_cs":[{"name":"","range":"50 °C až 500 °C","cmc":"3,0 °C"},{"name":"","range":"700 °C až 1200 °C","cmc":"9,0 °C"}],"technique":"Porównanie z termometrem wzorcowym","technique_en":"Comparison with a standard thermometer","technique_zh":"与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem","techniques":["Porównanie z termometrem wzorcowym"],"techniques_en":["Comparison with a standard thermometer"],"techniques_zh":["与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 50 °C do 500 °C CMC 3,0 °C\nod 700 °C do 1200 °C CMC 9,0 °C\nPorównanie z termometrem wzorcowym","reference":"02_KPIR","norm_bases":["02_KPIR"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Bezkontaktowe termometry na podczerwień Wzorcowanie – temperatura Porównanie z termometrem wzorcowym od 50 °C do 500 °C CMC 3,0 °C od 700 °C do 1200 °C CMC 9,0 °C Bezdotykové infračervené teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem 50 °C až 500 °C CMC 3,0 °C 700 °C až 1200 °C CMC 9,0 °C 02_KPIR Bezkontaktowe termometry na podczerwien Wzorcowanie – temperatura Porownanie z termometrem wzorcowym od 50 °C do 500 °C CMC 3,0 °C od 700 °C do 1200 °C CMC 9,0 °C Bezdotykove infracervene teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem 50 °C az 500 °C CMC 3,0 °C 700 °C az 1200 °C CMC 9,0 °C 02_KPIR","search_en":"Non-contact infrared thermometers Calibration – temperature Comparison with a standard thermometer 50 °C to 500 °C CMC 3,0 °C 700 °C to 1200 °C CMC 9,0 °C 02_KPIR","search_zh":"非接触式红外温度计 校准 – 温度 与标准温度计比较 50 °C 至 500 °C CMC 3,0 °C 700 °C 至 1200 °C CMC 9,0 °C 02_KPIR","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b7d1fe6e6ffc9bce9d4a8dd","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermoelectric temperature sensors","test_object_zh":"热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 50 °C","cmc":"1,5 °C"}],"parameters_en":[{"name":"","range":"0 °C to 50 °C","cmc":"1,5 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 50 °C","cmc":"1,5 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 50 °C","cmc":"1,5 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecyku z medium ciekłym","technique_en":"Comparison with a standard thermometer in a furnace with a liquid medium","technique_zh":"在带液体介质的校准炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v pícce s kapalným médiem","techniques":["Porównanie z termometrem wzorcowym w piecyku z medium ciekłym"],"techniques_en":["Comparison with a standard thermometer in a furnace with a liquid medium"],"techniques_zh":["在带液体介质的校准炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v pícce s kapalným médiem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 0 °C do 50 °C CMC 1,5 °C\nPorównanie z termometrem wzorcowym w piecyku z medium ciekłym","reference":"02_KPN","norm_bases":["02_KPN"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecyku z medium ciekłym od 0 °C do 50 °C CMC 1,5 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v pícce s kapalným médiem 0 °C až 50 °C CMC 1,5 °C 02_KPN Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecyku z medium cieklym od 0 °C do 50 °C CMC 1,5 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v picce s kapalnym mediem 0 °C az 50 °C CMC 1,5 °C 02_KPN","search_en":"Thermoelectric temperature sensors Calibration – temperature Comparison with a standard thermometer in a furnace with a liquid medium 0 °C to 50 °C CMC 1,5 °C 02_KPN","search_zh":"热电式温度传感器 校准 – 温度 在带液体介质的校准炉中与标准温度计比较 0 °C 至 50 °C CMC 1,5 °C 02_KPN","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"47866e5d126c3dc6b323b5a9","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermoelectric temperature sensors","test_object_zh":"热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 50 °C do 200 °C","cmc":"1,3 °C"}],"parameters_en":[{"name":"","range":"50 °C to 200 °C","cmc":"1,3 °C"}],"parameters_zh":[{"name":"","range":"50 °C 至 200 °C","cmc":"1,3 °C"}],"parameters_cs":[{"name":"","range":"50 °C až 200 °C","cmc":"1,3 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej / piecu poziomym","technique_en":"Comparison with a standard thermometer in a liquid bath / horizontal furnace","technique_zh":"在液体槽 / 卧式炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalné lázni/horizontální peci","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej / piecu poziomym"],"techniques_en":["Comparison with a standard thermometer in a liquid bath / horizontal furnace"],"techniques_zh":["在液体槽 / 卧式炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalné lázni/horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 50 °C do 200 °C CMC 1,3 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej / piecu poziomym","reference":"02_KPN","norm_bases":["02_KPN"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej / piecu poziomym od 50 °C do 200 °C CMC 1,3 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalné lázni/horizontální peci 50 °C až 200 °C CMC 1,3 °C 02_KPN Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej / piecu poziomym od 50 °C do 200 °C CMC 1,3 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalne lazni/horizontalni peci 50 °C az 200 °C CMC 1,3 °C 02_KPN","search_en":"Thermoelectric temperature sensors Calibration – temperature Comparison with a standard thermometer in a liquid bath / horizontal furnace 50 °C to 200 °C CMC 1,3 °C 02_KPN","search_zh":"热电式温度传感器 校准 – 温度 在液体槽 / 卧式炉中与标准温度计比较 50 °C 至 200 °C CMC 1,3 °C 02_KPN","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"075733a47ffec811849cc0da","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermoelectric temperature sensors","test_object_zh":"热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 200 °C do 400 °C","cmc":"1,7 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"1,8 °C"},{"name":"","range":"od 600 °C do 700 °C","cmc":"3,6 °C"},{"name":"","range":"od 700 °C do 900 °C","cmc":"4,8 °C"},{"name":"","range":"od 900 °C do 1200 °C","cmc":"6,0 °C"}],"parameters_en":[{"name":"","range":"200 °C to 400 °C","cmc":"1,7 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"1,8 °C"},{"name":"","range":"600 °C to 700 °C","cmc":"3,6 °C"},{"name":"","range":"700 °C to 900 °C","cmc":"4,8 °C"},{"name":"","range":"900 °C to 1200 °C","cmc":"6,0 °C"}],"parameters_zh":[{"name":"","range":"200 °C 至 400 °C","cmc":"1,7 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"1,8 °C"},{"name":"","range":"600 °C 至 700 °C","cmc":"3,6 °C"},{"name":"","range":"700 °C 至 900 °C","cmc":"4,8 °C"},{"name":"","range":"900 °C 至 1200 °C","cmc":"6,0 °C"}],"parameters_cs":[{"name":"","range":"200 °C až 400 °C","cmc":"1,7 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"1,8 °C"},{"name":"","range":"600 °C až 700 °C","cmc":"3,6 °C"},{"name":"","range":"700 °C až 900 °C","cmc":"4,8 °C"},{"name":"","range":"900 °C až 1200 °C","cmc":"6,0 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecu poziomym","technique_en":"Comparison with a standard thermometer in a horizontal furnace","technique_zh":"在卧式炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v horizontální peci","techniques":["Porównanie z termometrem wzorcowym w piecu poziomym"],"techniques_en":["Comparison with a standard thermometer in a horizontal furnace"],"techniques_zh":["在卧式炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 200 °C do 400 °C CMC 1,7 °C\nod 400 °C do 600 °C CMC 1,8 °C\nod 600 °C do 700 °C CMC 3,6 °C\nod 700 °C do 900 °C CMC 4,8 °C\nod 900 °C do 1200 °C CMC 6,0 °C\nPorównanie z termometrem wzorcowym w piecu poziomym","reference":"02_KPN","norm_bases":["02_KPN"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecu poziomym od 200 °C do 400 °C CMC 1,7 °C od 400 °C do 600 °C CMC 1,8 °C od 600 °C do 700 °C CMC 3,6 °C od 700 °C do 900 °C CMC 4,8 °C od 900 °C do 1200 °C CMC 6,0 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v horizontální peci 200 °C až 400 °C CMC 1,7 °C 400 °C až 600 °C CMC 1,8 °C 600 °C až 700 °C CMC 3,6 °C 700 °C až 900 °C CMC 4,8 °C 900 °C až 1200 °C CMC 6,0 °C 02_KPN Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecu poziomym od 200 °C do 400 °C CMC 1,7 °C od 400 °C do 600 °C CMC 1,8 °C od 600 °C do 700 °C CMC 3,6 °C od 700 °C do 900 °C CMC 4,8 °C od 900 °C do 1200 °C CMC 6,0 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v horizontalni peci 200 °C az 400 °C CMC 1,7 °C 400 °C az 600 °C CMC 1,8 °C 600 °C az 700 °C CMC 3,6 °C 700 °C az 900 °C CMC 4,8 °C 900 °C az 1200 °C CMC 6,0 °C 02_KPN","search_en":"Thermoelectric temperature sensors Calibration – temperature Comparison with a standard thermometer in a horizontal furnace 200 °C to 400 °C CMC 1,7 °C 400 °C to 600 °C CMC 1,8 °C 600 °C to 700 °C CMC 3,6 °C 700 °C to 900 °C CMC 4,8 °C 900 °C to 1200 °C CMC 6,0 °C 02_KPN","search_zh":"热电式温度传感器 校准 – 温度 在卧式炉中与标准温度计比较 200 °C 至 400 °C CMC 1,7 °C 400 °C 至 600 °C CMC 1,8 °C 600 °C 至 700 °C CMC 3,6 °C 700 °C 至 900 °C CMC 4,8 °C 900 °C 至 1200 °C CMC 6,0 °C 02_KPN","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d73e22ca712bd7c4333f406e","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"3","test_object":"Tory pomiarowe – symulacja elektrycznego sygnału wejściowego","test_object_en":"Measuring chains – simulation of the electrical input signal","test_object_zh":"测量链 – 模拟电输入信号","test_object_cs":"Měřící řetězce – simulace elektrického vstupního signálu","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Termoelementy typu K","range":"od -100 °C do 1370 °C","cmc":"0,6 °C"},{"name":"Termoelementy typu N","range":"od -100 °C do 1300 °C","cmc":"0,9 °C"},{"name":"Termoelementy typu S","range":"od -50 °C do 1760 °C","cmc":"1,1 °C"},{"name":"Termoelementy typu R","range":"od -50 °C do 1760 °C","cmc":"0,8 °C"},{"name":"Termoelementy typu J","range":"od -100 °C do 1200 °C","cmc":"0,6 °C"},{"name":"Termoelementy typu T","range":"od -100 °C do 400 °C","cmc":"0,6 °C"},{"name":"Termometry rezystancyjne Pt100","range":"od -200 °C do 200 °C","cmc":"0,2 °C"},{"name":"Termometry rezystancyjne Pt100","range":"od 200 °C do 850 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"Thermocouples type K","range":"-100 °C to 1370 °C","cmc":"0,6 °C"},{"name":"Thermocouples type N","range":"-100 °C to 1300 °C","cmc":"0,9 °C"},{"name":"Thermocouples type S","range":"-50 °C to 1760 °C","cmc":"1,1 °C"},{"name":"Thermocouples type R","range":"-50 °C to 1760 °C","cmc":"0,8 °C"},{"name":"Thermocouples type J","range":"-100 °C to 1200 °C","cmc":"0,6 °C"},{"name":"Thermocouples type T","range":"-100 °C to 400 °C","cmc":"0,6 °C"},{"name":"Resistance thermometers Pt100","range":"-200 °C to 200 °C","cmc":"0,2 °C"},{"name":"Resistance thermometers Pt100","range":"200 °C to 850 °C","cmc":"0,3 °C"}],"parameters_zh":[{"name":"K 型热电偶","range":"-100 °C 至 1370 °C","cmc":"0,6 °C"},{"name":"N 型热电偶","range":"-100 °C 至 1300 °C","cmc":"0,9 °C"},{"name":"S 型热电偶","range":"-50 °C 至 1760 °C","cmc":"1,1 °C"},{"name":"R 型热电偶","range":"-50 °C 至 1760 °C","cmc":"0,8 °C"},{"name":"J 型热电偶","range":"-100 °C 至 1200 °C","cmc":"0,6 °C"},{"name":"T 型热电偶","range":"-100 °C 至 400 °C","cmc":"0,6 °C"},{"name":"Pt100 电阻温度计","range":"-200 °C 至 200 °C","cmc":"0,2 °C"},{"name":"Pt100 电阻温度计","range":"200 °C 至 850 °C","cmc":"0,3 °C"}],"parameters_cs":[{"name":"Termočlánky typu K","range":"-100 °C až 1370 °C","cmc":"0,6 °C"},{"name":"Termočlánky typu N","range":"-100 °C až 1300 °C","cmc":"0,9 °C"},{"name":"Termočlánky typu S","range":"-50 °C až 1760 °C","cmc":"1,1 °C"},{"name":"Termočlánky typu R","range":"-50 °C až 1760 °C","cmc":"0,8 °C"},{"name":"Termočlánky typu J","range":"-100 °C až 1200 °C","cmc":"0,6 °C"},{"name":"Termočlánky typu T","range":"-100 °C až 400 °C","cmc":"0,6 °C"},{"name":"Odporové teploměry Pt100","range":"-200 °C až 200 °C","cmc":"0,2 °C"},{"name":"Odporové teploměry Pt100","range":"200 °C až 850 °C","cmc":"0,3 °C"}],"technique":"Pomiar bezpośredni sygnału kalibratora wzorcowego","technique_en":"Direct measurement of the reference calibrator signal","technique_zh":"直接测量标准校准器信号","technique_cs":"Přímé měření signálu etalonového kalibrátoru","techniques":["Pomiar bezpośredni sygnału kalibratora wzorcowego"],"techniques_en":["Direct measurement of the reference calibrator signal"],"techniques_zh":["直接测量标准校准器信号"],"techniques_cs":["Přímé měření signálu etalonového kalibrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nTermoelementy typu K od -100 °C do 1370 °C CMC 0,6 °C\nTermoelementy typu N od -100 °C do 1300 °C CMC 0,9 °C\nTermoelementy typu S od -50 °C do 1760 °C CMC 1,1 °C\nTermoelementy typu R od -50 °C do 1760 °C CMC 0,8 °C\nTermoelementy typu J od -100 °C do 1200 °C CMC 0,6 °C\nTermoelementy typu T od -100 °C do 400 °C CMC 0,6 °C\nTermometry rezystancyjne Pt100 od -200 °C do 200 °C CMC 0,2 °C\nTermometry rezystancyjne Pt100 od 200 °C do 850 °C CMC 0,3 °C\nPomiar bezpośredni sygnału kalibratora wzorcowego","reference":"02_KPR","norm_bases":["02_KPR"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tory pomiarowe – symulacja elektrycznego sygnału wejściowego Wzorcowanie – temperatura Pomiar bezpośredni sygnału kalibratora wzorcowego Termoelementy typu K od -100 °C do 1370 °C CMC 0,6 °C Termoelementy typu N od -100 °C do 1300 °C CMC 0,9 °C Termoelementy typu S od -50 °C do 1760 °C CMC 1,1 °C Termoelementy typu R od -50 °C do 1760 °C CMC 0,8 °C Termoelementy typu J od -100 °C do 1200 °C CMC 0,6 °C Termoelementy typu T od -100 °C do 400 °C CMC 0,6 °C Termometry rezystancyjne Pt100 od -200 °C do 200 °C CMC 0,2 °C Termometry rezystancyjne Pt100 od 200 °C do 850 °C CMC 0,3 °C Měřící řetězce – simulace elektrického vstupního signálu Kalibrace – teplota Přímé měření signálu etalonového kalibrátoru Termočlánky typu K -100 °C až 1370 °C CMC 0,6 °C Termočlánky typu N -100 °C až 1300 °C CMC 0,9 °C Termočlánky typu S -50 °C až 1760 °C CMC 1,1 °C Termočlánky typu R -50 °C až 1760 °C CMC 0,8 °C Termočlánky typu J -100 °C až 1200 °C CMC 0,6 °C Termočlánky typu T -100 °C až 400 °C CMC 0,6 °C Odporové teploměry Pt100 -200 °C až 200 °C CMC 0,2 °C Odporové teploměry Pt100 200 °C až 850 °C CMC 0,3 °C 02_KPR Tory pomiarowe – symulacja elektrycznego sygnalu wejsciowego Wzorcowanie – temperatura Pomiar bezposredni sygnalu kalibratora wzorcowego Termoelementy typu K od -100 °C do 1370 °C CMC 0,6 °C Termoelementy typu N od -100 °C do 1300 °C CMC 0,9 °C Termoelementy typu S od -50 °C do 1760 °C CMC 1,1 °C Termoelementy typu R od -50 °C do 1760 °C CMC 0,8 °C Termoelementy typu J od -100 °C do 1200 °C CMC 0,6 °C Termoelementy typu T od -100 °C do 400 °C CMC 0,6 °C Termometry rezystancyjne Pt100 od -200 °C do 200 °C CMC 0,2 °C Termometry rezystancyjne Pt100 od 200 °C do 850 °C CMC 0,3 °C Merici retezce – simulace elektrickeho vstupniho signalu Kalibrace – teplota Prime mereni signalu etalonoveho kalibratoru Termoclanky typu K -100 °C az 1370 °C CMC 0,6 °C Termoclanky typu N -100 °C az 1300 °C CMC 0,9 °C Termoclanky typu S -50 °C az 1760 °C CMC 1,1 °C Termoclanky typu R -50 °C az 1760 °C CMC 0,8 °C Termoclanky typu J -100 °C az 1200 °C CMC 0,6 °C Termoclanky typu T -100 °C az 400 °C CMC 0,6 °C Odporove teplomery Pt100 -200 °C az 200 °C CMC 0,2 °C Odporove teplomery Pt100 200 °C az 850 °C CMC 0,3 °C 02_KPR","search_en":"Measuring chains – simulation of the electrical input signal Calibration – temperature Direct measurement of the reference calibrator signal Thermocouples type K -100 °C to 1370 °C CMC 0,6 °C Thermocouples type N -100 °C to 1300 °C CMC 0,9 °C Thermocouples type S -50 °C to 1760 °C CMC 1,1 °C Thermocouples type R -50 °C to 1760 °C CMC 0,8 °C Thermocouples type J -100 °C to 1200 °C CMC 0,6 °C Thermocouples type T -100 °C to 400 °C CMC 0,6 °C Resistance thermometers Pt100 -200 °C to 200 °C CMC 0,2 °C Resistance thermometers Pt100 200 °C to 850 °C CMC 0,3 °C 02_KPR","search_zh":"测量链 – 模拟电输入信号 校准 – 温度 直接测量标准校准器信号 K 型热电偶 -100 °C 至 1370 °C CMC 0,6 °C N 型热电偶 -100 °C 至 1300 °C CMC 0,9 °C S 型热电偶 -50 °C 至 1760 °C CMC 1,1 °C R 型热电偶 -50 °C 至 1760 °C CMC 0,8 °C J 型热电偶 -100 °C 至 1200 °C CMC 0,6 °C T 型热电偶 -100 °C 至 400 °C CMC 0,6 °C Pt100 电阻温度计 -200 °C 至 200 °C CMC 0,2 °C Pt100 电阻温度计 200 °C 至 850 °C CMC 0,3 °C 02_KPR","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3d86932eef3d48125f68126b","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"3","test_object":"Tory pomiarowe – symulacja elektrycznego sygnału wejściowego","test_object_en":"Measuring chains – simulation of the electrical input signal","test_object_zh":"测量链 – 模拟电输入信号","test_object_cs":"Měřící řetězce – simulace elektrického vstupního signálu","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Wyjście prądowe przetwornika","range":"od -200 °C do -50 °C","cmc":"0,2 °C"},{"name":"Wyjście prądowe przetwornika","range":"od -50 °C do 50 °C","cmc":"0,1 °C"},{"name":"Wyjście prądowe przetwornika","range":"od 50 °C do 200 °C","cmc":"0,2 °C"},{"name":"Wyjście prądowe przetwornika","range":"od 200 °C do 400 °C","cmc":"0,3 °C"},{"name":"Wyjście prądowe przetwornika","range":"od 400 °C do 600 °C","cmc":"0,5 °C"}],"parameters_en":[{"name":"Current output of the transmitter","range":"-200 °C to -50 °C","cmc":"0,2 °C"},{"name":"Current output of the transmitter","range":"-50 °C to 50 °C","cmc":"0,1 °C"},{"name":"Current output of the transmitter","range":"50 °C to 200 °C","cmc":"0,2 °C"},{"name":"Current output of the transmitter","range":"200 °C to 400 °C","cmc":"0,3 °C"},{"name":"Current output of the transmitter","range":"400 °C to 600 °C","cmc":"0,5 °C"}],"parameters_zh":[{"name":"变送器电流输出","range":"-200 °C 至 -50 °C","cmc":"0,2 °C"},{"name":"变送器电流输出","range":"-50 °C 至 50 °C","cmc":"0,1 °C"},{"name":"变送器电流输出","range":"50 °C 至 200 °C","cmc":"0,2 °C"},{"name":"变送器电流输出","range":"200 °C 至 400 °C","cmc":"0,3 °C"},{"name":"变送器电流输出","range":"400 °C 至 600 °C","cmc":"0,5 °C"}],"parameters_cs":[{"name":"Proudový výstup převodníku","range":"-200 °C až -50 °C","cmc":"0,2 °C"},{"name":"Proudový výstup převodníku","range":"-50 °C až 50 °C","cmc":"0,1 °C"},{"name":"Proudový výstup převodníku","range":"50 °C až 200 °C","cmc":"0,2 °C"},{"name":"Proudový výstup převodníku","range":"200 °C až 400 °C","cmc":"0,3 °C"},{"name":"Proudový výstup převodníku","range":"400 °C až 600 °C","cmc":"0,5 °C"}],"technique":"Porównanie z kalibratorem procesowym","technique_en":"Comparison with a process calibrator","technique_zh":"与过程校准器比较","technique_cs":"Porovnání s procesním kalibrátorem","techniques":["Porównanie z kalibratorem procesowym"],"techniques_en":["Comparison with a process calibrator"],"techniques_zh":["与过程校准器比较"],"techniques_cs":["Porovnání s procesním kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nWyjście prądowe przetwornika od -200 °C do -50 °C CMC 0,2 °C\nWyjście prądowe przetwornika od -50 °C do 50 °C CMC 0,1 °C\nWyjście prądowe przetwornika od 50 °C do 200 °C CMC 0,2 °C\nWyjście prądowe przetwornika od 200 °C do 400 °C CMC 0,3 °C\nWyjście prądowe przetwornika od 400 °C do 600 °C CMC 0,5 °C\nPorównanie z kalibratorem procesowym","reference":"02_KPR","norm_bases":["02_KPR"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tory pomiarowe – symulacja elektrycznego sygnału wejściowego Wzorcowanie – temperatura Porównanie z kalibratorem procesowym Wyjście prądowe przetwornika od -200 °C do -50 °C CMC 0,2 °C Wyjście prądowe przetwornika od -50 °C do 50 °C CMC 0,1 °C Wyjście prądowe przetwornika od 50 °C do 200 °C CMC 0,2 °C Wyjście prądowe przetwornika od 200 °C do 400 °C CMC 0,3 °C Wyjście prądowe przetwornika od 400 °C do 600 °C CMC 0,5 °C Měřící řetězce – simulace elektrického vstupního signálu Kalibrace – teplota Porovnání s procesním kalibrátorem Proudový výstup převodníku -200 °C až -50 °C CMC 0,2 °C Proudový výstup převodníku -50 °C až 50 °C CMC 0,1 °C Proudový výstup převodníku 50 °C až 200 °C CMC 0,2 °C Proudový výstup převodníku 200 °C až 400 °C CMC 0,3 °C Proudový výstup převodníku 400 °C až 600 °C CMC 0,5 °C 02_KPR Tory pomiarowe – symulacja elektrycznego sygnalu wejsciowego Wzorcowanie – temperatura Porownanie z kalibratorem procesowym Wyjscie pradowe przetwornika od -200 °C do -50 °C CMC 0,2 °C Wyjscie pradowe przetwornika od -50 °C do 50 °C CMC 0,1 °C Wyjscie pradowe przetwornika od 50 °C do 200 °C CMC 0,2 °C Wyjscie pradowe przetwornika od 200 °C do 400 °C CMC 0,3 °C Wyjscie pradowe przetwornika od 400 °C do 600 °C CMC 0,5 °C Merici retezce – simulace elektrickeho vstupniho signalu Kalibrace – teplota Porovnani s procesnim kalibratorem Proudovy vystup prevodniku -200 °C az -50 °C CMC 0,2 °C Proudovy vystup prevodniku -50 °C az 50 °C CMC 0,1 °C Proudovy vystup prevodniku 50 °C az 200 °C CMC 0,2 °C Proudovy vystup prevodniku 200 °C az 400 °C CMC 0,3 °C Proudovy vystup prevodniku 400 °C az 600 °C CMC 0,5 °C 02_KPR","search_en":"Measuring chains – simulation of the electrical input signal Calibration – temperature Comparison with a process calibrator Current output of the transmitter -200 °C to -50 °C CMC 0,2 °C Current output of the transmitter -50 °C to 50 °C CMC 0,1 °C Current output of the transmitter 50 °C to 200 °C CMC 0,2 °C Current output of the transmitter 200 °C to 400 °C CMC 0,3 °C Current output of the transmitter 400 °C to 600 °C CMC 0,5 °C 02_KPR","search_zh":"测量链 – 模拟电输入信号 校准 – 温度 与过程校准器比较 变送器电流输出 -200 °C 至 -50 °C CMC 0,2 °C 变送器电流输出 -50 °C 至 50 °C CMC 0,1 °C 变送器电流输出 50 °C 至 200 °C CMC 0,2 °C 变送器电流输出 200 °C 至 400 °C CMC 0,3 °C 变送器电流输出 400 °C 至 600 °C CMC 0,5 °C 02_KPR","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6a5c3b53f4461a5c26c2338e","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"4","test_object":"Termometry wskazujące, tory pomiarowe temperatury, rejestratory danych","test_object_en":"Indicating thermometers, temperature measuring chains, dataloggers","test_object_zh":"指示式温度计、温度测量链、数据记录器","test_object_cs":"Indikační teploměry, měřící řetězce teploty, dataloggery","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 5 °C","cmc":"0,4 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 5 °C","cmc":"0,4 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 5 °C","cmc":"0,4 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 5 °C","cmc":"0,4 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecyku z medium ciekłym","technique_en":"Comparison with a standard thermometer in a furnace with a liquid medium","technique_zh":"在带液体介质的校准炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v pícce s kapalným médiem","techniques":["Porównanie z termometrem wzorcowym w piecyku z medium ciekłym"],"techniques_en":["Comparison with a standard thermometer in a furnace with a liquid medium"],"techniques_zh":["在带液体介质的校准炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v pícce s kapalným médiem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -30 °C do 5 °C CMC 0,4 °C\nPorównanie z termometrem wzorcowym w piecyku z medium ciekłym","reference":"02_KPP","norm_bases":["02_KPP"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące, tory pomiarowe temperatury, rejestratory danych Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecyku z medium ciekłym od -30 °C do 5 °C CMC 0,4 °C Indikační teploměry, měřící řetězce teploty, dataloggery Kalibrace – teplota Porovnání s etalonovým teploměrem v pícce s kapalným médiem -30 °C až 5 °C CMC 0,4 °C 02_KPP Termometry wskazujace, tory pomiarowe temperatury, rejestratory danych Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecyku z medium cieklym od -30 °C do 5 °C CMC 0,4 °C Indikacni teplomery, merici retezce teploty, dataloggery Kalibrace – teplota Porovnani s etalonovym teplomerem v picce s kapalnym mediem -30 °C az 5 °C CMC 0,4 °C 02_KPP","search_en":"Indicating thermometers, temperature measuring chains, dataloggers Calibration – temperature Comparison with a standard thermometer in a furnace with a liquid medium -30 °C to 5 °C CMC 0,4 °C 02_KPP","search_zh":"指示式温度计、温度测量链、数据记录器 校准 – 温度 在带液体介质的校准炉中与标准温度计比较 -30 °C 至 5 °C CMC 0,4 °C 02_KPP","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"18d5ad96df61f1f832bcd74e","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"4","test_object":"Termometry wskazujące, tory pomiarowe temperatury, rejestratory danych","test_object_en":"Indicating thermometers, temperature measuring chains, dataloggers","test_object_zh":"指示式温度计、温度测量链、数据记录器","test_object_cs":"Indikační teploměry, měřící řetězce teploty, dataloggery","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0 °C","cmc":"0,1 °C"}],"parameters_en":[{"name":"","range":"0 °C","cmc":"0,1 °C"}],"parameters_zh":[{"name":"","range":"0 °C","cmc":"0,1 °C"}],"parameters_cs":[{"name":"","range":"0 °C","cmc":"0,1 °C"}],"technique":"Porównanie z termometrem wzorcowym","technique_en":"Comparison with a standard thermometer","technique_zh":"与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem","techniques":["Porównanie z termometrem wzorcowym"],"techniques_en":["Comparison with a standard thermometer"],"techniques_zh":["与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n0 °C CMC 0,1 °C\nPorównanie z termometrem wzorcowym","reference":"02_KPP","norm_bases":["02_KPP"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące, tory pomiarowe temperatury, rejestratory danych Wzorcowanie – temperatura Porównanie z termometrem wzorcowym 0 °C CMC 0,1 °C Indikační teploměry, měřící řetězce teploty, dataloggery Kalibrace – teplota Porovnání s etalonovým teploměrem 0 °C CMC 0,1 °C 02_KPP Termometry wskazujace, tory pomiarowe temperatury, rejestratory danych Wzorcowanie – temperatura Porownanie z termometrem wzorcowym 0 °C CMC 0,1 °C Indikacni teplomery, merici retezce teploty, dataloggery Kalibrace – teplota Porovnani s etalonovym teplomerem 0 °C CMC 0,1 °C 02_KPP","search_en":"Indicating thermometers, temperature measuring chains, dataloggers Calibration – temperature Comparison with a standard thermometer 0 °C CMC 0,1 °C 02_KPP","search_zh":"指示式温度计、温度测量链、数据记录器 校准 – 温度 与标准温度计比较 0 °C CMC 0,1 °C 02_KPP","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9133037102b769f55baeb4c9","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"4","test_object":"Termometry wskazujące, tory pomiarowe temperatury, rejestratory danych","test_object_en":"Indicating thermometers, temperature measuring chains, dataloggers","test_object_zh":"指示式温度计、温度测量链、数据记录器","test_object_cs":"Indikační teploměry, měřící řetězce teploty, dataloggery","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 5 °C do 150 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"","range":"5 °C to 150 °C","cmc":"0,15 °C"}],"parameters_zh":[{"name":"","range":"5 °C 至 150 °C","cmc":"0,15 °C"}],"parameters_cs":[{"name":"","range":"5 °C až 150 °C","cmc":"0,15 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a standard thermometer in a liquid bath","technique_zh":"在液体槽中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalné lázni","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a standard thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalné lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 5 °C do 150 °C CMC 0,15 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej","reference":"02_KPP","norm_bases":["02_KPP"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące, tory pomiarowe temperatury, rejestratory danych Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej od 5 °C do 150 °C CMC 0,15 °C Indikační teploměry, měřící řetězce teploty, dataloggery Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalné lázni 5 °C až 150 °C CMC 0,15 °C 02_KPP Termometry wskazujace, tory pomiarowe temperatury, rejestratory danych Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej od 5 °C do 150 °C CMC 0,15 °C Indikacni teplomery, merici retezce teploty, dataloggery Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalne lazni 5 °C az 150 °C CMC 0,15 °C 02_KPP","search_en":"Indicating thermometers, temperature measuring chains, dataloggers Calibration – temperature Comparison with a standard thermometer in a liquid bath 5 °C to 150 °C CMC 0,15 °C 02_KPP","search_zh":"指示式温度计、温度测量链、数据记录器 校准 – 温度 在液体槽中与标准温度计比较 5 °C 至 150 °C CMC 0,15 °C 02_KPP","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2772708a9d54446ff8a6837f","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"4","test_object":"Termometry wskazujące, tory pomiarowe temperatury, rejestratory danych","test_object_en":"Indicating thermometers, temperature measuring chains, dataloggers","test_object_zh":"指示式温度计、温度测量链、数据记录器","test_object_cs":"Indikační teploměry, měřící řetězce teploty, dataloggery","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 150 °C do 200 °C","cmc":"0,4 °C"},{"name":"","range":"od 200 °C do 400 °C","cmc":"1,1 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"2,1 °C"},{"name":"","range":"od 600 °C do 900 °C","cmc":"4,8 °C"},{"name":"","range":"od 900 °C do 1200 °C","cmc":"6,0 °C"}],"parameters_en":[{"name":"","range":"150 °C to 200 °C","cmc":"0,4 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"1,1 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"2,1 °C"},{"name":"","range":"600 °C to 900 °C","cmc":"4,8 °C"},{"name":"","range":"900 °C to 1200 °C","cmc":"6,0 °C"}],"parameters_zh":[{"name":"","range":"150 °C 至 200 °C","cmc":"0,4 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"1,1 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"2,1 °C"},{"name":"","range":"600 °C 至 900 °C","cmc":"4,8 °C"},{"name":"","range":"900 °C 至 1200 °C","cmc":"6,0 °C"}],"parameters_cs":[{"name":"","range":"150 °C až 200 °C","cmc":"0,4 °C"},{"name":"","range":"200 °C až 400 °C","cmc":"1,1 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"2,1 °C"},{"name":"","range":"600 °C až 900 °C","cmc":"4,8 °C"},{"name":"","range":"900 °C až 1200 °C","cmc":"6,0 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecu poziomym","technique_en":"Comparison with a standard thermometer in a horizontal furnace","technique_zh":"在卧式炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v horizontální peci","techniques":["Porównanie z termometrem wzorcowym w piecu poziomym"],"techniques_en":["Comparison with a standard thermometer in a horizontal furnace"],"techniques_zh":["在卧式炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 150 °C do 200 °C CMC 0,4 °C\nod 200 °C do 400 °C CMC 1,1 °C\nod 400 °C do 600 °C CMC 2,1 °C\nod 600 °C do 900 °C CMC 4,8 °C\nod 900 °C do 1200 °C CMC 6,0 °C\nPorównanie z termometrem wzorcowym w piecu poziomym","reference":"02_KPP","norm_bases":["02_KPP"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące, tory pomiarowe temperatury, rejestratory danych Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecu poziomym od 150 °C do 200 °C CMC 0,4 °C od 200 °C do 400 °C CMC 1,1 °C od 400 °C do 600 °C CMC 2,1 °C od 600 °C do 900 °C CMC 4,8 °C od 900 °C do 1200 °C CMC 6,0 °C Indikační teploměry, měřící řetězce teploty, dataloggery Kalibrace – teplota Porovnání s etalonovým teploměrem v horizontální peci 150 °C až 200 °C CMC 0,4 °C 200 °C až 400 °C CMC 1,1 °C 400 °C až 600 °C CMC 2,1 °C 600 °C až 900 °C CMC 4,8 °C 900 °C až 1200 °C CMC 6,0 °C 02_KPP Termometry wskazujace, tory pomiarowe temperatury, rejestratory danych Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecu poziomym od 150 °C do 200 °C CMC 0,4 °C od 200 °C do 400 °C CMC 1,1 °C od 400 °C do 600 °C CMC 2,1 °C od 600 °C do 900 °C CMC 4,8 °C od 900 °C do 1200 °C CMC 6,0 °C Indikacni teplomery, merici retezce teploty, dataloggery Kalibrace – teplota Porovnani s etalonovym teplomerem v horizontalni peci 150 °C az 200 °C CMC 0,4 °C 200 °C az 400 °C CMC 1,1 °C 400 °C az 600 °C CMC 2,1 °C 600 °C az 900 °C CMC 4,8 °C 900 °C az 1200 °C CMC 6,0 °C 02_KPP","search_en":"Indicating thermometers, temperature measuring chains, dataloggers Calibration – temperature Comparison with a standard thermometer in a horizontal furnace 150 °C to 200 °C CMC 0,4 °C 200 °C to 400 °C CMC 1,1 °C 400 °C to 600 °C CMC 2,1 °C 600 °C to 900 °C CMC 4,8 °C 900 °C to 1200 °C CMC 6,0 °C 02_KPP","search_zh":"指示式温度计、温度测量链、数据记录器 校准 – 温度 在卧式炉中与标准温度计比较 150 °C 至 200 °C CMC 0,4 °C 200 °C 至 400 °C CMC 1,1 °C 400 °C 至 600 °C CMC 2,1 °C 600 °C 至 900 °C CMC 4,8 °C 900 °C 至 1200 °C CMC 6,0 °C 02_KPP","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9230f315a1fa0eaf48d3c503","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"5","test_object":"Urządzenia temperaturowe z regulacją temperatury","test_object_en":"Temperature equipment with temperature control","test_object_zh":"带温度调节的温控设备","test_object_cs":"Teplotní zařízení s regulací teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 150 °C","cmc":"0,6 °C"},{"name":"","range":"od 150 °C do 500 °C","cmc":"3,0 °C"},{"name":"","range":"od 500 °C do 900 °C","cmc":"5,3 °C"},{"name":"","range":"od 900 °C do 1200 °C","cmc":"6,5 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 150 °C","cmc":"0,6 °C"},{"name":"","range":"150 °C to 500 °C","cmc":"3,0 °C"},{"name":"","range":"500 °C to 900 °C","cmc":"5,3 °C"},{"name":"","range":"900 °C to 1200 °C","cmc":"6,5 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 150 °C","cmc":"0,6 °C"},{"name":"","range":"150 °C 至 500 °C","cmc":"3,0 °C"},{"name":"","range":"500 °C 至 900 °C","cmc":"5,3 °C"},{"name":"","range":"900 °C 至 1200 °C","cmc":"6,5 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 150 °C","cmc":"0,6 °C"},{"name":"","range":"150 °C až 500 °C","cmc":"3,0 °C"},{"name":"","range":"500 °C až 900 °C","cmc":"5,3 °C"},{"name":"","range":"900 °C až 1200 °C","cmc":"6,5 °C"}],"technique":"Porównanie z termometrem wzorcowym","technique_en":"Comparison with a standard thermometer","technique_zh":"与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem","techniques":["Porównanie z termometrem wzorcowym"],"techniques_en":["Comparison with a standard thermometer"],"techniques_zh":["与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 150 °C CMC 0,6 °C\nod 150 °C do 500 °C CMC 3,0 °C\nod 500 °C do 900 °C CMC 5,3 °C\nod 900 °C do 1200 °C CMC 6,5 °C\nPorównanie z termometrem wzorcowym","reference":"02_KPP","norm_bases":["02_KPP"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia temperaturowe z regulacją temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym od -30 °C do 150 °C CMC 0,6 °C od 150 °C do 500 °C CMC 3,0 °C od 500 °C do 900 °C CMC 5,3 °C od 900 °C do 1200 °C CMC 6,5 °C Teplotní zařízení s regulací teploty Kalibrace – teplota Porovnání s etalonovým teploměrem -30 °C až 150 °C CMC 0,6 °C 150 °C až 500 °C CMC 3,0 °C 500 °C až 900 °C CMC 5,3 °C 900 °C až 1200 °C CMC 6,5 °C 02_KPP Urzadzenia temperaturowe z regulacja temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym od -30 °C do 150 °C CMC 0,6 °C od 150 °C do 500 °C CMC 3,0 °C od 500 °C do 900 °C CMC 5,3 °C od 900 °C do 1200 °C CMC 6,5 °C Teplotni zarizeni s regulaci teploty Kalibrace – teplota Porovnani s etalonovym teplomerem -30 °C az 150 °C CMC 0,6 °C 150 °C az 500 °C CMC 3,0 °C 500 °C az 900 °C CMC 5,3 °C 900 °C az 1200 °C CMC 6,5 °C 02_KPP","search_en":"Temperature equipment with temperature control Calibration – temperature Comparison with a standard thermometer -30 °C to 150 °C CMC 0,6 °C 150 °C to 500 °C CMC 3,0 °C 500 °C to 900 °C CMC 5,3 °C 900 °C to 1200 °C CMC 6,5 °C 02_KPP","search_zh":"带温度调节的温控设备 校准 – 温度 与标准温度计比较 -30 °C 至 150 °C CMC 0,6 °C 150 °C 至 500 °C CMC 3,0 °C 500 °C 至 900 °C CMC 5,3 °C 900 °C 至 1200 °C CMC 6,5 °C 02_KPP","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aacbaf74c19bef4dec35e40e","lab_id":"6ade8b54ff06824761708145","country":"CZ","accr_number":"2409","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność względna / wzorcowanie torów regulacji wilgotności","test_object_en":"Relative humidity / calibration of humidity control chains","test_object_zh":"相对湿度 / 湿度调节链校准","test_object_cs":"Relativní vlhkost / kalibrace regulačních řetězců vlhkosti","methodology":"Wzorcowanie – wilgotność","methodology_en":"Calibration – humidity","methodology_zh":"校准 – 湿度","methodology_cs":"Kalibrace – vlhkost","parameters":[{"name":"(10 do 23) °C","range":"od 20 % RH do 90 % RH","cmc":"5 % RH"},{"name":"(23 do 35) °C","range":"od 10 % RH do 90 % RH","cmc":"5 % RH"}],"parameters_en":[{"name":"(10 to 23) °C","range":"20 % RH to 90 % RH","cmc":"5 % RH"},{"name":"(23 to 35) °C","range":"10 % RH to 90 % RH","cmc":"5 % RH"}],"parameters_zh":[{"name":"（10 至 23）°C","range":"20 % RH 至 90 % RH","cmc":"5 % RH"},{"name":"（23 至 35）°C","range":"10 % RH 至 90 % RH","cmc":"5 % RH"}],"parameters_cs":[{"name":"(10 až 23) °C","range":"20 % RH až 90 % RH","cmc":"5 % RH"},{"name":"(23 až 35) °C","range":"10 % RH až 90 % RH","cmc":"5 % RH"}],"technique":"Porównanie z higrometrem wzorcowym","technique_en":"Comparison with a standard hygrometer","technique_zh":"与标准湿度计比较","technique_cs":"Porovnání s etalonovým vlhkoměrem","techniques":["Porównanie z higrometrem wzorcowym"],"techniques_en":["Comparison with a standard hygrometer"],"techniques_zh":["与标准湿度计比较"],"techniques_cs":["Porovnání s etalonovým vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność\nZakres:\n(10 do 23) °C od 20 % RH do 90 % RH CMC 5 % RH\n(23 do 35) °C od 10 % RH do 90 % RH CMC 5 % RH\nPorównanie z higrometrem wzorcowym","reference":"02_KPV","norm_bases":["02_KPV"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność","regulatory_area_en":"CMC for the field of measured quantity: Humidity","regulatory_area_zh":"被测量领域的CMC：湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność względna / wzorcowanie torów regulacji wilgotności Wzorcowanie – wilgotność Porównanie z higrometrem wzorcowym (10 do 23) °C od 20 % RH do 90 % RH CMC 5 % RH (23 do 35) °C od 10 % RH do 90 % RH CMC 5 % RH Relativní vlhkost / kalibrace regulačních řetězců vlhkosti Kalibrace – vlhkost Porovnání s etalonovým vlhkoměrem (10 až 23) °C 20 % RH až 90 % RH CMC 5 % RH (23 až 35) °C 10 % RH až 90 % RH CMC 5 % RH 02_KPV Wilgotnosc wzgledna / wzorcowanie torow regulacji wilgotnosci Wzorcowanie – wilgotnosc Porownanie z higrometrem wzorcowym (10 do 23) °C od 20 % RH do 90 % RH CMC 5 % RH (23 do 35) °C od 10 % RH do 90 % RH CMC 5 % RH Relativni vlhkost / kalibrace regulacnich retezcu vlhkosti Kalibrace – vlhkost Porovnani s etalonovym vlhkomerem (10 az 23) °C 20 % RH az 90 % RH CMC 5 % RH (23 az 35) °C 10 % RH az 90 % RH CMC 5 % RH 02_KPV","search_en":"Relative humidity / calibration of humidity control chains Calibration – humidity Comparison with a standard hygrometer (10 to 23) °C 20 % RH to 90 % RH CMC 5 % RH (23 to 35) °C 10 % RH to 90 % RH CMC 5 % RH 02_KPV","search_zh":"相对湿度 / 湿度调节链校准 校准 – 湿度 与标准湿度计比较 （10 至 23）°C 20 % RH 至 90 % RH CMC 5 % RH （23 至 35）°C 10 % RH 至 90 % RH CMC 5 % RH 02_KPV","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}