🇨🇿 Vysoké učení technické v Brně PL
Metrology & calibration
Vysoké učení technické v Brně is a calibration laboratory accredited by ČIA under number 2395 (Brno, Czech Republic). Its accreditation scope covers 25 calibration items in the following areas: Metrology & calibration. Calibrated items include: AC Voltage / AC voltage sources and meters, AC voltmeters, multimet…, Acceleration of harmonic vibrations / Vibrometers without a transdu…, Acceleration of linear harmonic mechanical vibrations / Vibrometers…, Acceleration of linear harmonic mechanical vibrations / Vibrometers…. Most frequently used calibration principles: By simulated electrical signal, Comparison with a reference sensor (ČSN ISO 16063-21), Direct measurement or comparison with a reference counter.
At a glance
- Accreditation number: ČIA 2395
- Calibration items in scope: 25
- Types of calibrated items: 25
- Calibration principles used: 14
- City: Brno, Czech Republic
- Valid until: 03-09-2030
- Accreditation number
- 2395
- Accreditation body
- ČIA
- Address
- Technická 3082/12, 616 00 Brno
- City
- Brno, Czech Republic
- Division
- Laboratorium wzorcujące CVVOZE
- Valid until
- 03-09-2030
What this laboratory calibrates (25)
- AC Voltage / AC voltage sources and meters, AC voltmeters, multimeters, signal analyzers, vibration meters, vibration sensor calibration systems, signal generators, controllers for vibration test systems — 1 calibration item
- Acceleration of harmonic vibrations / Vibrometers without a transducer, measuring chains without a transducer with an output to a display or a scale, vibration test system controllers — 1 calibration item
- Acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems — 1 calibration item
- Acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators — 1 calibration item
- DC current / DC current sources and meters, ammeters, multimeters — 1 calibration item
- DC Resistance / Resistors, resistance boxes, shunts, dividers — 1 calibration item
- DC Voltage / DC voltage sources and meters, voltmeters, multimeters, signal analyzers, vibration meters, vibration test system controllers — 1 calibration item
- Frequency / Signal generators, counters, multimeters, signal analyzers, vibration meters, calibration systems, vibration test system controllers — 1 calibration item
- Frequency of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems — 1 calibration item
- Frequency of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators — 1 calibration item
- Maximum value of half-sine wave mechanical shock acceleration / shock meters — 1 calibration item
- Period / Signal generators, counters, multimeters, signal analyzers, vibration meters, calibration systems, vibration test system controllers — 1 calibration item
- Phase shift of acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems — 1 calibration item
- Phase shift of acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators — 1 calibration item
- Sensitivity / Laser vibrometers with an electric output — 1 calibration item
- and 10 more
Calibration principles (14)
- By simulated electrical signal — 3 calibration items
- Comparison with a reference sensor (ČSN ISO 16063-21) — 3 calibration items
- Direct measurement or comparison with a reference counter — 3 calibration items
- Direct measurement or comparison with a reference multimeter — 3 calibration items
- Direct measurement with a laser vibrometer (ČSN ISO 16063-11) — 3 calibration items
- Direct measurement with a laser vibrometer (ČSN ISO 16063-41) — 2 calibration items
- Comparison with a reference sensor (ČSN ISO 16063-21, ČSN ISO 16063-44) — 1 calibration item
- Comparison with a reference sensor (ČSN ISO 16063-22) — 1 calibration item
- Comparison with a reference sensor using a known reaction mass (ČSN ISO 16063-22) — 1 calibration item
- Direct measurement by a reference multimeter — 1 calibration item
- Direct measurement or comparison with a reference sensor (ČSN ISO 16063-22) — 1 calibration item
- Direct measurement with a laser vibrometer (ČSN ISO 16063-11, ČSN ISO 16063-44) — 1 calibration item
- Measurement or comparison on a standard calibration device or with a reference frequency counter (ČSN ISO 16063-21, ČSN ISO 16063-44) — 1 calibration item
- Measurement or comparison on a standard calibration device or with a standard frequency counter (ČSN ISO 16063-11, ČSN ISO 16063-44) — 1 calibration item
Certificate information
- Certificate date
- 03.09.2025
Accreditation scope — calibration items (25)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems | Calibration – mechanical motion 0,2 Hz to 0,4 Hz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 1,5 % 0,4 to 1 Hz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 1,0 % 1 Hz to 1 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 0,5 % 1 to 5 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 0,7 % 5 to 10 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 1,5 % 10 to 15 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 2,0 % 15 to 20 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 3,0 % CMC for the field of measured quantity: Mechanical motion |
Comparison with a reference sensor (ČSN ISO 16063-21, ČSN ISO 16063-44) | KP-01 | |
| 2 | Acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators | Calibration – mechanical motion 0,2 Hz to 0,4 Hz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 0,7 % 0,4 Hz to 1 Hz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 0,5 % 1 Hz to 1 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 0,3 % 1 kHz to 5 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 0,5 % 5 kHz to 10 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 1,0 % 10 kHz to 15 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 2,0 % 15 kHz to 20 kHz — 0,01 m·s⁻² to 1000 m·s⁻² · CMC 2,5 % CMC for the field of measured quantity: Mechanical motion |
Direct measurement with a laser vibrometer (ČSN ISO 16063-11, ČSN ISO 16063-44) | KP-01 | |
| 3 | Phase shift of acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems | Calibration – mechanical motion 0,2 Hz to 1 Hz — 0 ° to 360 ° · CMC 1,5 ° 1 Hz to 5 kHz — 0 ° to 360 ° · CMC 0,7 ° 5 kHz to 10 kHz — 0 ° to 360 ° · CMC 1,0 ° 10 kHz to 15 kHz — 0 ° to 360 ° · CMC 2,0 ° 15 kHz to 20 kHz — 0 ° to 360 ° · CMC 3,0 ° CMC for the field of measured quantity: Mechanical motion |
Comparison with a reference sensor (ČSN ISO 16063-21) | KP-01 | |
| 4 | Phase shift of acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators | Calibration – mechanical motion 0,2 Hz to 0,4 Hz — 0 ° to 360 ° · CMC 0,7 ° 0,4 Hz to 5 kHz — 0 ° to 360 ° · CMC 0,5 ° 5 kHz to 10 kHz — 0 ° to 360 ° · CMC 1,0 ° 10 kHz to 15 kHz — 0 ° to 360 ° · CMC 2,0 ° 15 kHz to 20 kHz — 0 ° to 360 ° · CMC 3,0 ° CMC for the field of measured quantity: Mechanical motion |
Direct measurement with a laser vibrometer (ČSN ISO 16063-11) | KP-01 | |
| 5 | Sensitivity / Vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output | Calibration – mechanical motion 0,2 Hz to 0,4 Hz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 1,5 % 0,4 Hz to 1 Hz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 1,0 % 1 Hz to 1 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 0,5 % 1 kHz to 5 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 0,7 % 5 kHz to 10 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 1,5 % 10 kHz to 15 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 2,0 % 15 kHz to 20 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 3,0 % 0,2 Hz to 0,4 Hz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 1,5 % 0,4 Hz to 1 Hz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 1,0 % 1 Hz to 1 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 0,5 % 1 kHz to 5 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 0,7 % 5 kHz to 10 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 1,5 % 10 kHz to 15 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 2,0 % 15 kHz to 20 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 3,0 % 0,2 Hz to 0,4 Hz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 1,5 % 0,4 Hz to 1 Hz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 1,0 % 1 Hz to 1 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,5 % 1 kHz to 5 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,7 % 5 kHz to 10 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 1,5 % 10 kHz to 15 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 2,0 % 15 kHz to 20 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 3,0 % 0,2 Hz to 0,4 Hz — 0,01 V/m to 10 000 V/m · CMC 1,5 % 0,4 Hz to 1 Hz — 0,01 V/m to 10 000 V/m · CMC 1,0 % 1 Hz to 1 kHz — 0,01 V/m to 10 000 V/m · CMC 0,5 % 1 kHz to 5 kHz — 0,01 V/m to 10 000 V/m · CMC 0,7 % 5 kHz to 10 kHz — 0,01 V/m to 10 000 V/m · CMC 1,5 % 10 kHz to 15 kHz — 0,01 V/m to 10 000 V/m · CMC 2,0 % 15 kHz to 20 kHz — 0,01 V/m to 10 000 V/m · CMC 3,0 % CMC for the field of measured quantity: Mechanical motion |
Comparison with a reference sensor (ČSN ISO 16063-21) | KP-01 | |
| 6 | Sensitivity / Vibration transducers, standard vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output | Calibration – mechanical motion 0,2 Hz to 0,4 Hz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 0,7 % 0,4 Hz to 1 Hz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 0,5 % 1 Hz to 1 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 0,3 % 1 kHz to 5 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 0,5 % 5 kHz to 10 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 1,0 % 10 kHz to 15 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 2,0 % 15 kHz to 20 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 2,5 % 0,2 Hz to 0,4 Hz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 0,7 % 0,4 Hz to 1 Hz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 0,5 % 1 Hz to 1 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 0,3 % 1 kHz to 5 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 0,5 % 5 kHz to 10 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 1,0 % 10 kHz to 15 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 2,0 % 15 kHz to 20 kHz — 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² · CMC 2,5 % 0,2 Hz to 0,4 Hz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,7 % 0,4 Hz to 1 Hz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,5 % 1 Hz to 1 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,3 % 1 kHz to 5 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,5 % 5 kHz to 10 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 1,0 % 10 kHz to 15 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 2,0 % 15 kHz to 20 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 2,5 % 0,2 Hz to 0,4 Hz — 0,01 V/m to 10 000 V/m · CMC 0,7 % 0,4 Hz to 1 Hz — 0,01 V/m to 10 000 V/m · CMC 0,5 % 1 Hz to 1 kHz — 0,01 V/m to 10 000 V/m · CMC 0,3 % 1 kHz to 5 kHz — 0,01 V/m to 10 000 V/m · CMC 0,5 % 5 kHz to 10 kHz — 0,01 V/m to 10 000 V/m · CMC 1,0 % 10 kHz to 15 kHz — 0,01 V/m to 10 000 V/m · CMC 2,0 % 15 kHz to 20 kHz — 0,01 V/m to 10 000 V/m · CMC 2,5 % CMC for the field of measured quantity: Mechanical motion |
Direct measurement with a laser vibrometer (ČSN ISO 16063-11) | KP-01 | |
| 7 | Sensitivity / Laser vibrometers with an electric output | Calibration – mechanical motion 0,2 Hz to 5 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,25 % 5 kHz to 10 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,3 % 10 kHz to 15 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,5 % 15 kHz to 20 kHz — 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ · CMC 0,7 % 0,2 Hz to 5 kHz — 0,01 V/m to 10 000 V/m · CMC 0,25 % 5 kHz to 10 kHz — 0,01 V/m to 10 000 V/m · CMC 0,3 % 10 kHz to 15 kHz — 0,01 V/m to 10 000 V/m · CMC 0,5 % 15 kHz to 20 kHz — 0,01 V/m to 10 000 V/m · CMC 0,7 % CMC for the field of measured quantity: Mechanical motion |
Direct measurement with a laser vibrometer (ČSN ISO 16063-41) | KP-01 | |
| 8 | Sensitivity phase shift / Vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output | Calibration – mechanical motion 0,2 Hz to 1 Hz — 0 ° to 360 ° · CMC 1,5 ° 1 Hz to 5 kHz — 0 ° to 360 ° · CMC 0,7 ° 5 kHz to 10 kHz — 0 ° to 360 ° · CMC 1,0 ° 10 kHz to 15 kHz — 0 ° to 360 ° · CMC 2,0 ° 15 kHz to 20 kHz — 0 ° to 360 ° · CMC 3,0 ° CMC for the field of measured quantity: Mechanical motion |
Comparison with a reference sensor (ČSN ISO 16063-21) | KP-01 | |
| 9 | Sensitivity phase shift / Vibration transducers, standard vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output | Calibration – mechanical motion 0,2 Hz to 0,4 Hz — 0 ° to 360 ° · CMC 0,7 ° 0,4 Hz to 5 kHz — 0 ° to 360 ° · CMC 0,5 ° 5 kHz to 10 kHz — 0 ° to 360 ° · CMC 1,0 ° 10 kHz to 15 kHz — 0 ° to 360 ° · CMC 2,0 ° 15 kHz to 20 kHz — 0 ° to 360 ° · CMC 3,0 ° CMC for the field of measured quantity: Mechanical motion |
Direct measurement with a laser vibrometer (ČSN ISO 16063-11) | KP-01 | |
| 10 | Sensitivity phase shift / Laser vibrometers with an electric output | Calibration – mechanical motion 0,2 Hz to 5 kHz — 0 ° to 360 ° · CMC 0,5 ° 5 kHz to 10 kHz — 0 ° to 360 ° · CMC 0,7 ° 10 kHz to 20 kHz — 0 ° to 360 ° · CMC 1,5 ° CMC for the field of measured quantity: Mechanical motion |
Direct measurement with a laser vibrometer (ČSN ISO 16063-41) | KP-01 | |
| 11 | Frequency of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems | Calibration – mechanical motion 0,2 Hz to 50 kHz · CMC 0,01 % CMC for the field of measured quantity: Mechanical motion |
Measurement or comparison on a standard calibration device or with a reference frequency counter (ČSN ISO 16063-21, ČSN ISO 16063-44) | KP-01 | |
| 12 | Frequency of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators | Calibration – mechanical motion 0,2 Hz to 50 kHz · CMC 0,01 % CMC for the field of measured quantity: Mechanical motion |
Measurement or comparison on a standard calibration device or with a standard frequency counter (ČSN ISO 16063-11, ČSN ISO 16063-44) | KP-01 | |
| 13 | Transfer / Charge amplifiers, voltage amplifiers, frequency filters, vibration test system controllers | Calibration – mechanical motion 0,1 Hz to 1 Hz — 0,001 mV/pC to 1000 mV/pC · CMC 0,4 % 1 Hz to 20 kHz — 0,001 mV/pC to 1000 mV/pC · CMC 0,3 % 20 kHz to 50 kHz — 0,001 mV/pC to 1000 mV/pC · CMC 1,0 % 0,1 Hz to 1 Hz — 0,001 V/V to 1000 V/V · CMC 0,4 % 1 Hz to 20 kHz — 0,001 V/V to 1000 V/V · CMC 0,3 % 20 kHz to 50 kHz — 0,001 V/V to 1000 V/V · CMC 1,0 % CMC for the field of measured quantity: Mechanical motion |
By simulated electrical signal | KP-02 | |
| 14 | Transfer phase shift / Charge amplifiers, voltage amplifiers, frequency filters, vibration test system controllers | Calibration – mechanical motion 0,1 Hz to 1 Hz — 0 ° to 360 ° · CMC 0,75 ° 1 Hz to 20 kHz — 0 ° to 360 ° · CMC 0,5 ° CMC for the field of measured quantity: Mechanical motion |
By simulated electrical signal | KP-02 | |
| 15 | Acceleration of harmonic vibrations / Vibrometers without a transducer, measuring chains without a transducer with an output to a display or a scale, vibration test system controllers | Calibration – mechanical motion 0,1 Hz to 1 Hz — 0,01 m·s⁻² to 10 000 m·s⁻² · CMC 0,4 % 1 Hz to 20 kHz — 0,01 m·s⁻² to 10 000 m·s⁻² · CMC 0,3 % CMC for the field of measured quantity: Mechanical motion |
By simulated electrical signal | KP-02 | |
| 16 | Maximum value of half-sine wave mechanical shock acceleration / shock meters | Calibration – mechanical motion 50 m·s⁻² to 200 m·s⁻² · CMC 2,0 % 200 m·s⁻² to 2 km·s⁻² · CMC 1,5 % 2 km·s⁻² to 40 km·s⁻² · CMC 1,8 % 40 km·s⁻² to 100 km·s⁻² · CMC 3,0 % CMC for the field of measured quantity: Mechanical motion |
Direct measurement or comparison with a reference sensor (ČSN ISO 16063-22) | KP-01 | |
| 17 | Sensitivity of half-sine wave mechanical shock acceleration sensors / shock sensors, vibration sensors | Calibration – mechanical motion 50 m·s⁻² to 200 m·s⁻² — 0,0001 mV/m·s⁻² to 100 mV/m·s⁻² · CMC 2,0 % 200 m·s⁻² to 2 km·s⁻² — 0,0001 mV/m·s⁻² to 100 mV/m·s⁻² · CMC 1,5 % 2 to 40 km·s⁻² — 0,0001 mV/m·s⁻² to 100 mV/m·s⁻² · CMC 1,8 % 40 to 100 km·s⁻² — 0,0001 mV/m·s⁻² to 100 mV/m·s⁻² · CMC 3,0 % 50 m·s⁻² to 200 m·s⁻² — 0,0001 pC/m·s⁻² to 100 pC/m·s⁻² · CMC 2,0 % 200 m·s⁻² to 2 km·s⁻² — 0,0001 pC/m·s⁻² to 100 pC/m·s⁻² · CMC 1,5 % 2 to 40 km·s⁻² — 0,0001 pC/m·s⁻² to 100 pC/m·s⁻² · CMC 1,8 % 40 to 100 km·s⁻² — 0,0001 pC/m·s⁻² to 100 pC/m·s⁻² · CMC 3,0 % CMC for the field of measured quantity: Mechanical motion |
Comparison with a reference sensor (ČSN ISO 16063-22) | KP-01 | |
| 18 | Sensitivity of half-sine wave mechanical shock sensors / shock hammers | Calibration – mechanical motion 0,1 mV/N to 100 mV/N · CMC 3,0 % 0,1 pC/N to 100 pC/N · CMC 3,0 % CMC for the field of measured quantity: Mechanical motion |
Comparison with a reference sensor using a known reaction mass (ČSN ISO 16063-22) | KP-01 | |
| 19 | DC Voltage / DC voltage sources and meters, voltmeters, multimeters, signal analyzers, vibration meters, vibration test system controllers | Calibration – electrical quantities 0 mV to 100 mV · CMC 0,010 % + 0,010 mV 100 mV to 1 V · CMC 0,010 % + 0,020 mV 1 V to 10 V · CMC 0,010 % + 0,10 mV 10 V to 100 V · CMC 0,010 % + 1,0 mV CMC for the field of measured quantity: Electrical quantities |
Direct measurement or comparison with a reference multimeter | KP-03 | |
| 20 | DC current / DC current sources and meters, ammeters, multimeters | Calibration – electrical quantities 0 mA to 1 mA · CMC 0,10 % + 0,10 uA 1 mA to 10 mA · CMC 0,10 % + 5,0 uA 10 mA to 100 mA · CMC 0,10 % + 10 uA 100 mA to 1 A · CMC 0,20 % + 0,20 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement or comparison with a reference multimeter | KP-03 | |
| 21 | DC Resistance / Resistors, resistance boxes, shunts, dividers | Calibration – electrical quantities 0 Ω to 100 Ω · CMC 0,020 % + 0,010 Ω 100 Ω to 1 kΩ · CMC 0,020 % + 0,020 Ω 1 kΩ to 10 kΩ · CMC 0,020 % + 0,20 Ω 10 kΩ to 100 kΩ · CMC 0,020 % + 2,0 Ω 100 kΩ to 1 MΩ · CMC 0,025 % + 20 Ω 1 MΩ to 10 MΩ · CMC 0,10 % + 200 Ω CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a reference multimeter | KP-03 | |
| 22 | AC Voltage / AC voltage sources and meters, AC voltmeters, multimeters, signal analyzers, vibration meters, vibration sensor calibration systems, signal generators, controllers for vibration test systems | Calibration – electrical quantities 10 Hz to 20 kHz — 1 mV to 100 mV · CMC 0,10 % + 0,050 mV 20 kHz to 50 kHz — 1 mV to 100 mV · CMC 0,20 % + 0,10 mV 50 kHz to 100 kHz — 1 mV to 100 mV · CMC 0,80 % + 0,15 mV 10 Hz to 20 kHz — 100 mV to 1 V · CMC 0,10 % + 0,50 mV 20 kHz to 50 kHz — 100 mV to 1 V · CMC 0,20 % + 1,0 mV 50 kHz to 100 kHz — 100 mV to 1 V · CMC 0,80 % + 1,5 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 0,10 % + 5,0 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 0,20 % + 10 mV 50 kHz to 100 kHz — 1 V to 10 V · CMC 0,80 % + 15 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 0,10 % + 50 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 0,20 % + 100 mV 50 kHz to 100 kHz — 10 V to 100 V · CMC 0,80 % + 150 mV CMC for the field of measured quantity: Electrical quantities |
Direct measurement or comparison with a reference multimeter | KP-03 | |
| 23 | Frequency / Signal generators, counters, multimeters, signal analyzers, vibration meters, calibration systems, vibration test system controllers | Calibration – time and frequency quantities 15 mV to 250 mV — 0,1 Hz to 100 kHz · CMC 2,0·10⁻⁴/f 250 mV to 50 V — 0,1 Hz to 100 kHz · CMC 2,0·10⁻⁵/f 15 mV to 250 mV — 100 kHz to 1 MHz · CMC 2,0·10⁻⁹ 250 mV to 50 V — 100 kHz to 1 MHz · CMC 2,0·10⁻¹⁰ 15 mV to 50 V — 1 MHz to 10 MHz · CMC 2,0·10⁻¹⁰ CMC for the field of measured quantity: Time and frequency quantities |
Direct measurement or comparison with a reference counter | KP-03 | |
| 24 | Period / Signal generators, counters, multimeters, signal analyzers, vibration meters, calibration systems, vibration test system controllers | Calibration – time and frequency quantities 15 mV to 50 V — 100 ns to 1 µs · CMC 2,0·10⁻¹⁰ 15 mV to 250 mV — 1 µs to 10 µs · CMC 2,0·10⁻⁹ 250 mV to 50 V — 1 µs to 10 µs · CMC 2,0·10⁻¹⁰ 15 mV to 250 mV — 10 µs to 10 s · CMC 2,0·10⁻⁴·T 250 mV to 50 V — 10 µs to 10 s · CMC 2,0·10⁻⁵·T CMC for the field of measured quantity: Time and frequency quantities |
Direct measurement or comparison with a reference counter | KP-03 | |
| 25 | Time interval / Signal generators, timers, counters, multimeters, signal analyzers | Calibration – time and frequency quantities 250 mV to 50 V — 0,1 ms to 1000 s · CMC 5,0·10⁻⁵ CMC for the field of measured quantity: Time and frequency quantities |
Direct measurement or comparison with a reference counter | KP-03 | |
Reference standards (3)
KP-01
KP-02
KP-03