{"lab":{"_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","address":"Technická 3082/12, 616 00 Brno","categories":["metrology"],"city":"Brno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.5745734,49.2270222]},"map_coord":[49.2270222,16.5745734],"map_geo":"cai-mapa","methods_count":25,"name":"Vysoké učení technické v Brně","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: ruch mechaniczny, wielkości elektryczne oraz wielkości czasu i częstotliwości, w zakresie określonym w załączniku do świadectwa.","search_text":"vysoké učení technické v brně technická 3082/12, 616 00 brno 2395","source_page_url":"https://www.cai.cz/?subjekt=2395-vysoke-uceni-technicke-v-brne","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"03-09-2030","website":"www.vut.cz","certificate_date":"03.09.2025","certificate_no":"449/2025","certificate_replaces":"269/2023 z 31.05.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: ruch mechaniczny, wielkości elektryczne oraz wielkości czasu i częstotliwości, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the fields of mechanical motion, electrical quantities and time and frequency quantities to the extent as specified in the appendix to this Certificate.","zh":"机械运动、电学量以及时间和频率量领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru mechanický pohyb, elektrické veličiny a veličiny času a frekvence, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące CVVOZE","lab_division_cs":"Kalibrační laboratoř CVVOZE","lab_division_en":"CVVOZE Calibration Laboratory","lab_division_zh":"CVVOZE 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"0b2619c399fb3664e3586b5fa538b2a3213417c721d2e8a01acd679dc369f0eb","source_pdf_url":"https://www.cai.cz/OA/pdf/449_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/449_2025_EN.pdf"},"methods":[{"_id":"096b6d571237ed81411dc928","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"1","test_object":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, generatory drgań prostoliniowych, systemy do badań wibracyjnych","test_object_en":"Acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems","test_object_zh":"简谐直线机械振动加速度 / 测振仪、地震仪、直线振动发生器、振动测试系统","test_object_cs":"Zrychlení přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, generátory přímočarých vibrací, vibrační testovací systémy","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 0,4 Hz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"1,5 %"},{"name":"0,4 do 1 Hz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz do 1 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"0,5 %"},{"name":"1 do 5 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"0,7 %"},{"name":"5 do 10 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"1,5 %"},{"name":"10 do 15 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"2,0 %"},{"name":"15 do 20 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"3,0 %"}],"parameters_en":[{"name":"0,2 Hz to 0,4 Hz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"1,5 %"},{"name":"0,4 to 1 Hz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz to 1 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"0,5 %"},{"name":"1 to 5 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"0,7 %"},{"name":"5 to 10 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"1,5 %"},{"name":"10 to 15 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"2,0 %"},{"name":"15 to 20 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"3,0 %"}],"parameters_zh":[{"name":"0,2 Hz 至 0,4 Hz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"1,5 %"},{"name":"0,4 至 1 Hz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz 至 1 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"0,5 %"},{"name":"1 至 5 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"0,7 %"},{"name":"5 至 10 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"1,5 %"},{"name":"10 至 15 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"2,0 %"},{"name":"15 至 20 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"3,0 %"}],"parameters_cs":[{"name":"0,2 Hz až 0,4 Hz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"1,5 %"},{"name":"0,4 až 1 Hz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz až 1 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"0,5 %"},{"name":"1 až 5 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"0,7 %"},{"name":"5 až 10 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"1,5 %"},{"name":"10 až 15 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"2,0 %"},{"name":"15 až 20 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"3,0 %"}],"technique":"Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21, ČSN ISO 16063-44)","technique_en":"Comparison with a reference sensor (ČSN ISO 16063-21, ČSN ISO 16063-44)","technique_zh":"与参考传感器比较（ČSN ISO 16063-21、ČSN ISO 16063-44）","technique_cs":"Porovnání s referenčním snímačem (ČSN ISO 16063-21, ČSN ISO 16063-44)","techniques":["Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21, ČSN ISO 16063-44)"],"techniques_en":["Comparison with a reference sensor (ČSN ISO 16063-21, ČSN ISO 16063-44)"],"techniques_zh":["与参考传感器比较（ČSN ISO 16063-21、ČSN ISO 16063-44）"],"techniques_cs":["Porovnání s referenčním snímačem (ČSN ISO 16063-21, ČSN ISO 16063-44)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 0,4 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,5 %\n0,4 do 1 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,0 %\n1 Hz do 1 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,5 %\n1 do 5 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,7 %\n5 do 10 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,5 %\n10 do 15 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 2,0 %\n15 do 20 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 3,0 %\nPorównanie z czujnikiem referencyjnym (ČSN ISO 16063-21, ČSN ISO 16063-44)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":"Wielkością wzorcowaną mogą być także prędkość i wychylenie, pod warunkiem wzorcowania sygnałem drgań o przebiegu harmonicznym o znanej częstotliwości. Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻².","note_en":"The calibrated quantities may include also the velocity and deviation, if the calibration is carried out using a harmonic vibration signal of a known frequency. Acceleration can be specified also in g, sensor sensitivity in pC/g, resp. mV/g units, where 1 g = 9.807 m·s⁻².","note_zh":"被校量也可以是速度和位移，前提是使用已知频率的简谐振动信号进行校准。加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²。","note_cs":"Kalibrovanou veličinou mohou být i rychlost a výchylka, za předpokladu kalibrace pomocí vibračního signálu harmonického průběhu na známém kmitočtu. Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻².","search_text":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, generatory drgań prostoliniowych, systemy do badań wibracyjnych Wzorcowanie – ruch mechaniczny Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21, ČSN ISO 16063-44) 0,2 Hz do 0,4 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,5 % 0,4 do 1 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,0 % 1 Hz do 1 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,5 % 1 do 5 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,7 % 5 do 10 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,5 % 10 do 15 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 2,0 % 15 do 20 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 3,0 % Zrychlení přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, generátory přímočarých vibrací, vibrační testovací systémy Kalibrace – mechanický pohyb Porovnání s referenčním snímačem (ČSN ISO 16063-21, ČSN ISO 16063-44) 0,2 Hz až 0,4 Hz 0,01 m·s⁻² až 1000 m·s⁻² CMC 1,5 % 0,4 až 1 Hz 0,01 m·s⁻² až 1000 m·s⁻² CMC 1,0 % 1 Hz až 1 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 0,5 % 1 až 5 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 0,7 % 5 až 10 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 1,5 % 10 až 15 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 2,0 % 15 až 20 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 3,0 % KP-01 Przyspieszenie prostoliniowych drgan mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, generatory drgan prostoliniowych, systemy do badan wibracyjnych Wzorcowanie – ruch mechaniczny Porownanie z czujnikiem referencyjnym (CSN ISO 16063-21, CSN ISO 16063-44) 0,2 Hz do 0,4 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,5 % 0,4 do 1 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,0 % 1 Hz do 1 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,5 % 1 do 5 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,7 % 5 do 10 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,5 % 10 do 15 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 2,0 % 15 do 20 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 3,0 % Zrychleni primocarych mechanickych vibraci harmonickeho prubehu / Vibrometry, seismometry, generatory primocarych vibraci, vibracni testovaci systemy Kalibrace – mechanicky pohyb Porovnani s referencnim snimacem (CSN ISO 16063-21, CSN ISO 16063-44) 0,2 Hz az 0,4 Hz 0,01 m·s⁻² az 1000 m·s⁻² CMC 1,5 % 0,4 az 1 Hz 0,01 m·s⁻² az 1000 m·s⁻² CMC 1,0 % 1 Hz az 1 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 0,5 % 1 az 5 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 0,7 % 5 az 10 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 1,5 % 10 az 15 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 2,0 % 15 az 20 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 3,0 % KP-01","search_en":"Acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems Calibration – mechanical motion Comparison with a reference sensor (ČSN ISO 16063-21, ČSN ISO 16063-44) 0,2 Hz to 0,4 Hz 0,01 m·s⁻² to 1000 m·s⁻² CMC 1,5 % 0,4 to 1 Hz 0,01 m·s⁻² to 1000 m·s⁻² CMC 1,0 % 1 Hz to 1 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 0,5 % 1 to 5 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 0,7 % 5 to 10 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 1,5 % 10 to 15 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 2,0 % 15 to 20 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 3,0 % KP-01","search_zh":"简谐直线机械振动加速度 / 测振仪、地震仪、直线振动发生器、振动测试系统 校准 – 机械运动 与参考传感器比较（ČSN ISO 16063-21、ČSN ISO 16063-44） 0,2 Hz 至 0,4 Hz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 1,5 % 0,4 至 1 Hz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 1,0 % 1 Hz 至 1 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 0,5 % 1 至 5 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 0,7 % 5 至 10 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 1,5 % 10 至 15 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 2,0 % 15 至 20 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 3,0 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7301ee0ab4ffa789d3d915c6","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"2","test_object":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, systemy wzorcowania czujników drgań, referencyjne generatory drgań prostoliniowych","test_object_en":"Acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators","test_object_zh":"简谐直线机械振动加速度 / 测振仪、地震仪、振动传感器校准系统、参考直线振动发生器","test_object_cs":"Zrychlení přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, kalibrační systémy snímačů vibrací, referenční generátory přímočarých vibrací","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 0,4 Hz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz do 1 Hz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz do 1 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz do 5 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz do 10 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz do 15 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz do 20 kHz","range":"od 0,01 m·s⁻² do 1000 m·s⁻²","cmc":"2,5 %"}],"parameters_en":[{"name":"0,2 Hz to 0,4 Hz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz to 1 Hz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz to 1 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz to 5 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz to 10 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz to 15 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz to 20 kHz","range":"0,01 m·s⁻² to 1000 m·s⁻²","cmc":"2,5 %"}],"parameters_zh":[{"name":"0,2 Hz 至 0,4 Hz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz 至 1 Hz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz 至 1 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz 至 5 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz 至 10 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz 至 15 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz 至 20 kHz","range":"0,01 m·s⁻² 至 1000 m·s⁻²","cmc":"2,5 %"}],"parameters_cs":[{"name":"0,2 Hz až 0,4 Hz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz až 1 Hz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz až 1 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz až 5 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz až 10 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz až 15 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz až 20 kHz","range":"0,01 m·s⁻² až 1000 m·s⁻²","cmc":"2,5 %"}],"technique":"Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11, ČSN ISO 16063-44)","technique_en":"Direct measurement with a laser vibrometer (ČSN ISO 16063-11, ČSN ISO 16063-44)","technique_zh":"用激光测振仪直接测量（ČSN ISO 16063-11、ČSN ISO 16063-44）","technique_cs":"Přímé měření laserovým vibrometrem (ČSN ISO 16063-11, ČSN ISO 16063-44)","techniques":["Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11, ČSN ISO 16063-44)"],"techniques_en":["Direct measurement with a laser vibrometer (ČSN ISO 16063-11, ČSN ISO 16063-44)"],"techniques_zh":["用激光测振仪直接测量（ČSN ISO 16063-11、ČSN ISO 16063-44）"],"techniques_cs":["Přímé měření laserovým vibrometrem (ČSN ISO 16063-11, ČSN ISO 16063-44)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 0,4 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,7 %\n0,4 Hz do 1 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,5 %\n1 Hz do 1 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,3 %\n1 kHz do 5 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,5 %\n5 kHz do 10 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,0 %\n10 kHz do 15 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 2,0 %\n15 kHz do 20 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 2,5 %\nPomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11, ČSN ISO 16063-44)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością wzorcowaną mogą być także prędkość i wychylenie, pod warunkiem wzorcowania sygnałem drgań o przebiegu harmonicznym o znanej częstotliwości. Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻².","note_en":"The calibrated quantities may include also the velocity and deviation, if the calibration is carried out using a harmonic vibration signal of a known frequency. Acceleration can be specified also in g, sensor sensitivity in pC/g, resp. mV/g units, where 1 g = 9.807 m·s⁻².","note_zh":"被校量也可以是速度和位移，前提是使用已知频率的简谐振动信号进行校准。加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²。","note_cs":"Kalibrovanou veličinou mohou být i rychlost a výchylka, za předpokladu kalibrace pomocí vibračního signálu harmonického průběhu na známém kmitočtu. Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻².","search_text":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, systemy wzorcowania czujników drgań, referencyjne generatory drgań prostoliniowych Wzorcowanie – ruch mechaniczny Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11, ČSN ISO 16063-44) 0,2 Hz do 0,4 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,7 % 0,4 Hz do 1 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,5 % 1 Hz do 1 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,3 % 1 kHz do 5 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,5 % 5 kHz do 10 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,0 % 10 kHz do 15 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 2,5 % Zrychlení přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, kalibrační systémy snímačů vibrací, referenční generátory přímočarých vibrací Kalibrace – mechanický pohyb Přímé měření laserovým vibrometrem (ČSN ISO 16063-11, ČSN ISO 16063-44) 0,2 Hz až 0,4 Hz 0,01 m·s⁻² až 1000 m·s⁻² CMC 0,7 % 0,4 Hz až 1 Hz 0,01 m·s⁻² až 1000 m·s⁻² CMC 0,5 % 1 Hz až 1 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 0,3 % 1 kHz až 5 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 0,5 % 5 kHz až 10 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 1,0 % 10 kHz až 15 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 2,0 % 15 kHz až 20 kHz 0,01 m·s⁻² až 1000 m·s⁻² CMC 2,5 % KP-01 Przyspieszenie prostoliniowych drgan mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, systemy wzorcowania czujnikow drgan, referencyjne generatory drgan prostoliniowych Wzorcowanie – ruch mechaniczny Pomiar bezposredni wibrometrem laserowym (CSN ISO 16063-11, CSN ISO 16063-44) 0,2 Hz do 0,4 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,7 % 0,4 Hz do 1 Hz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,5 % 1 Hz do 1 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,3 % 1 kHz do 5 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 0,5 % 5 kHz do 10 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 1,0 % 10 kHz do 15 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 m·s⁻² do 1000 m·s⁻² CMC 2,5 % Zrychleni primocarych mechanickych vibraci harmonickeho prubehu / Vibrometry, seismometry, kalibracni systemy snimacu vibraci, referencni generatory primocarych vibraci Kalibrace – mechanicky pohyb Prime mereni laserovym vibrometrem (CSN ISO 16063-11, CSN ISO 16063-44) 0,2 Hz az 0,4 Hz 0,01 m·s⁻² az 1000 m·s⁻² CMC 0,7 % 0,4 Hz az 1 Hz 0,01 m·s⁻² az 1000 m·s⁻² CMC 0,5 % 1 Hz az 1 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 0,3 % 1 kHz az 5 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 0,5 % 5 kHz az 10 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 1,0 % 10 kHz az 15 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 2,0 % 15 kHz az 20 kHz 0,01 m·s⁻² az 1000 m·s⁻² CMC 2,5 % KP-01","search_en":"Acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators Calibration – mechanical motion Direct measurement with a laser vibrometer (ČSN ISO 16063-11, ČSN ISO 16063-44) 0,2 Hz to 0,4 Hz 0,01 m·s⁻² to 1000 m·s⁻² CMC 0,7 % 0,4 Hz to 1 Hz 0,01 m·s⁻² to 1000 m·s⁻² CMC 0,5 % 1 Hz to 1 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 0,3 % 1 kHz to 5 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 0,5 % 5 kHz to 10 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 1,0 % 10 kHz to 15 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 2,0 % 15 kHz to 20 kHz 0,01 m·s⁻² to 1000 m·s⁻² CMC 2,5 % KP-01","search_zh":"简谐直线机械振动加速度 / 测振仪、地震仪、振动传感器校准系统、参考直线振动发生器 校准 – 机械运动 用激光测振仪直接测量（ČSN ISO 16063-11、ČSN ISO 16063-44） 0,2 Hz 至 0,4 Hz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 0,7 % 0,4 Hz 至 1 Hz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 0,5 % 1 Hz 至 1 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 0,3 % 1 kHz 至 5 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 0,5 % 5 kHz 至 10 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 1,0 % 10 kHz 至 15 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 2,0 % 15 kHz 至 20 kHz 0,01 m·s⁻² 至 1000 m·s⁻² CMC 2,5 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e0cfdab5b56a9b093884c71b","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"3","test_object":"Przesunięcie fazowe przyspieszenia prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, generatory drgań prostoliniowych, systemy do badań wibracyjnych","test_object_en":"Phase shift of acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems","test_object_zh":"简谐直线机械振动加速度相移 / 测振仪、地震仪、直线振动发生器、振动测试系统","test_object_cs":"Fázový posuv zrychlení přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, generátory přímočarých vibrací, vibrační testovací systémy","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 1 Hz","range":"od 0 ° do 360 °","cmc":"1,5 °"},{"name":"1 Hz do 5 kHz","range":"od 0 ° do 360 °","cmc":"0,7 °"},{"name":"5 kHz do 10 kHz","range":"od 0 ° do 360 °","cmc":"1,0 °"},{"name":"10 kHz do 15 kHz","range":"od 0 ° do 360 °","cmc":"2,0 °"},{"name":"15 kHz do 20 kHz","range":"od 0 ° do 360 °","cmc":"3,0 °"}],"parameters_en":[{"name":"0,2 Hz to 1 Hz","range":"0 ° to 360 °","cmc":"1,5 °"},{"name":"1 Hz to 5 kHz","range":"0 ° to 360 °","cmc":"0,7 °"},{"name":"5 kHz to 10 kHz","range":"0 ° to 360 °","cmc":"1,0 °"},{"name":"10 kHz to 15 kHz","range":"0 ° to 360 °","cmc":"2,0 °"},{"name":"15 kHz to 20 kHz","range":"0 ° to 360 °","cmc":"3,0 °"}],"parameters_zh":[{"name":"0,2 Hz 至 1 Hz","range":"0 ° 至 360 °","cmc":"1,5 °"},{"name":"1 Hz 至 5 kHz","range":"0 ° 至 360 °","cmc":"0,7 °"},{"name":"5 kHz 至 10 kHz","range":"0 ° 至 360 °","cmc":"1,0 °"},{"name":"10 kHz 至 15 kHz","range":"0 ° 至 360 °","cmc":"2,0 °"},{"name":"15 kHz 至 20 kHz","range":"0 ° 至 360 °","cmc":"3,0 °"}],"parameters_cs":[{"name":"0,2 Hz až 1 Hz","range":"0 ° až 360 °","cmc":"1,5 °"},{"name":"1 Hz až 5 kHz","range":"0 ° až 360 °","cmc":"0,7 °"},{"name":"5 kHz až 10 kHz","range":"0 ° až 360 °","cmc":"1,0 °"},{"name":"10 kHz až 15 kHz","range":"0 ° až 360 °","cmc":"2,0 °"},{"name":"15 kHz až 20 kHz","range":"0 ° až 360 °","cmc":"3,0 °"}],"technique":"Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21)","technique_en":"Comparison with a reference sensor (ČSN ISO 16063-21)","technique_zh":"与参考传感器比较（ČSN ISO 16063-21）","technique_cs":"Porovnání s referenčním snímačem (ČSN ISO 16063-21)","techniques":["Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21)"],"techniques_en":["Comparison with a reference sensor (ČSN ISO 16063-21)"],"techniques_zh":["与参考传感器比较（ČSN ISO 16063-21）"],"techniques_cs":["Porovnání s referenčním snímačem (ČSN ISO 16063-21)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 1 Hz od 0 ° do 360 ° CMC 1,5 °\n1 Hz do 5 kHz od 0 ° do 360 ° CMC 0,7 °\n5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 °\n10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 °\n15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 °\nPorównanie z czujnikiem referencyjnym (ČSN ISO 16063-21)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością wzorcowaną mogą być także prędkość i wychylenie, pod warunkiem wzorcowania sygnałem drgań o przebiegu harmonicznym o znanej częstotliwości.","note_en":"The calibrated quantities may include also the velocity and deviation, if the calibration is carried out using a harmonic vibration signal of a known frequency.","note_zh":"被校量也可以是速度和位移，前提是使用已知频率的简谐振动信号进行校准。","note_cs":"Kalibrovanou veličinou mohou být i rychlost a výchylka, za předpokladu kalibrace pomocí vibračního signálu harmonického průběhu na známém kmitočtu.","search_text":"Przesunięcie fazowe przyspieszenia prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, generatory drgań prostoliniowych, systemy do badań wibracyjnych Wzorcowanie – ruch mechaniczny Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21) 0,2 Hz do 1 Hz od 0 ° do 360 ° CMC 1,5 ° 1 Hz do 5 kHz od 0 ° do 360 ° CMC 0,7 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 ° 10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 ° 15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 ° Fázový posuv zrychlení přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, generátory přímočarých vibrací, vibrační testovací systémy Kalibrace – mechanický pohyb Porovnání s referenčním snímačem (ČSN ISO 16063-21) 0,2 Hz až 1 Hz 0 ° až 360 ° CMC 1,5 ° 1 Hz až 5 kHz 0 ° až 360 ° CMC 0,7 ° 5 kHz až 10 kHz 0 ° až 360 ° CMC 1,0 ° 10 kHz až 15 kHz 0 ° až 360 ° CMC 2,0 ° 15 kHz až 20 kHz 0 ° až 360 ° CMC 3,0 ° KP-01 Przesuniecie fazowe przyspieszenia prostoliniowych drgan mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, generatory drgan prostoliniowych, systemy do badan wibracyjnych Wzorcowanie – ruch mechaniczny Porownanie z czujnikiem referencyjnym (CSN ISO 16063-21) 0,2 Hz do 1 Hz od 0 ° do 360 ° CMC 1,5 ° 1 Hz do 5 kHz od 0 ° do 360 ° CMC 0,7 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 ° 10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 ° 15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 ° Fazovy posuv zrychleni primocarych mechanickych vibraci harmonickeho prubehu / Vibrometry, seismometry, generatory primocarych vibraci, vibracni testovaci systemy Kalibrace – mechanicky pohyb Porovnani s referencnim snimacem (CSN ISO 16063-21) 0,2 Hz az 1 Hz 0 ° az 360 ° CMC 1,5 ° 1 Hz az 5 kHz 0 ° az 360 ° CMC 0,7 ° 5 kHz az 10 kHz 0 ° az 360 ° CMC 1,0 ° 10 kHz az 15 kHz 0 ° az 360 ° CMC 2,0 ° 15 kHz az 20 kHz 0 ° az 360 ° CMC 3,0 ° KP-01","search_en":"Phase shift of acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems Calibration – mechanical motion Comparison with a reference sensor (ČSN ISO 16063-21) 0,2 Hz to 1 Hz 0 ° to 360 ° CMC 1,5 ° 1 Hz to 5 kHz 0 ° to 360 ° CMC 0,7 ° 5 kHz to 10 kHz 0 ° to 360 ° CMC 1,0 ° 10 kHz to 15 kHz 0 ° to 360 ° CMC 2,0 ° 15 kHz to 20 kHz 0 ° to 360 ° CMC 3,0 ° KP-01","search_zh":"简谐直线机械振动加速度相移 / 测振仪、地震仪、直线振动发生器、振动测试系统 校准 – 机械运动 与参考传感器比较（ČSN ISO 16063-21） 0,2 Hz 至 1 Hz 0 ° 至 360 ° CMC 1,5 ° 1 Hz 至 5 kHz 0 ° 至 360 ° CMC 0,7 ° 5 kHz 至 10 kHz 0 ° 至 360 ° CMC 1,0 ° 10 kHz 至 15 kHz 0 ° 至 360 ° CMC 2,0 ° 15 kHz 至 20 kHz 0 ° 至 360 ° CMC 3,0 ° KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2412303038c4b4f7a36e2fd0","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"4","test_object":"Przesunięcie fazowe przyspieszenia prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, systemy wzorcowania czujników drgań, referencyjne generatory drgań prostoliniowych","test_object_en":"Phase shift of acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators","test_object_zh":"简谐直线机械振动加速度相移 / 测振仪、地震仪、振动传感器校准系统、参考直线振动发生器","test_object_cs":"Fázový posuv zrychlení přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, kalibrační systémy snímačů vibrací, referenční generátory přímočarých vibrací","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 0,4 Hz","range":"od 0 ° do 360 °","cmc":"0,7 °"},{"name":"0,4 Hz do 5 kHz","range":"od 0 ° do 360 °","cmc":"0,5 °"},{"name":"5 kHz do 10 kHz","range":"od 0 ° do 360 °","cmc":"1,0 °"},{"name":"10 kHz do 15 kHz","range":"od 0 ° do 360 °","cmc":"2,0 °"},{"name":"15 kHz do 20 kHz","range":"od 0 ° do 360 °","cmc":"3,0 °"}],"parameters_en":[{"name":"0,2 Hz to 0,4 Hz","range":"0 ° to 360 °","cmc":"0,7 °"},{"name":"0,4 Hz to 5 kHz","range":"0 ° to 360 °","cmc":"0,5 °"},{"name":"5 kHz to 10 kHz","range":"0 ° to 360 °","cmc":"1,0 °"},{"name":"10 kHz to 15 kHz","range":"0 ° to 360 °","cmc":"2,0 °"},{"name":"15 kHz to 20 kHz","range":"0 ° to 360 °","cmc":"3,0 °"}],"parameters_zh":[{"name":"0,2 Hz 至 0,4 Hz","range":"0 ° 至 360 °","cmc":"0,7 °"},{"name":"0,4 Hz 至 5 kHz","range":"0 ° 至 360 °","cmc":"0,5 °"},{"name":"5 kHz 至 10 kHz","range":"0 ° 至 360 °","cmc":"1,0 °"},{"name":"10 kHz 至 15 kHz","range":"0 ° 至 360 °","cmc":"2,0 °"},{"name":"15 kHz 至 20 kHz","range":"0 ° 至 360 °","cmc":"3,0 °"}],"parameters_cs":[{"name":"0,2 Hz až 0,4 Hz","range":"0 ° až 360 °","cmc":"0,7 °"},{"name":"0,4 Hz až 5 kHz","range":"0 ° až 360 °","cmc":"0,5 °"},{"name":"5 kHz až 10 kHz","range":"0 ° až 360 °","cmc":"1,0 °"},{"name":"10 kHz až 15 kHz","range":"0 ° až 360 °","cmc":"2,0 °"},{"name":"15 kHz až 20 kHz","range":"0 ° až 360 °","cmc":"3,0 °"}],"technique":"Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11)","technique_en":"Direct measurement with a laser vibrometer (ČSN ISO 16063-11)","technique_zh":"用激光测振仪直接测量（ČSN ISO 16063-11）","technique_cs":"Přímé měření laserovým vibrometrem (ČSN ISO 16063-11)","techniques":["Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11)"],"techniques_en":["Direct measurement with a laser vibrometer (ČSN ISO 16063-11)"],"techniques_zh":["用激光测振仪直接测量（ČSN ISO 16063-11）"],"techniques_cs":["Přímé měření laserovým vibrometrem (ČSN ISO 16063-11)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 0,4 Hz od 0 ° do 360 ° CMC 0,7 °\n0,4 Hz do 5 kHz od 0 ° do 360 ° CMC 0,5 °\n5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 °\n10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 °\n15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 °\nPomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością wzorcowaną mogą być także prędkość i wychylenie, pod warunkiem wzorcowania sygnałem drgań o przebiegu harmonicznym o znanej częstotliwości.","note_en":"The calibrated quantities may include also the velocity and deviation, if the calibration is carried out using a harmonic vibration signal of a known frequency.","note_zh":"被校量也可以是速度和位移，前提是使用已知频率的简谐振动信号进行校准。","note_cs":"Kalibrovanou veličinou mohou být i rychlost a výchylka, za předpokladu kalibrace pomocí vibračního signálu harmonického průběhu na známém kmitočtu.","search_text":"Przesunięcie fazowe przyspieszenia prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, systemy wzorcowania czujników drgań, referencyjne generatory drgań prostoliniowych Wzorcowanie – ruch mechaniczny Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11) 0,2 Hz do 0,4 Hz od 0 ° do 360 ° CMC 0,7 ° 0,4 Hz do 5 kHz od 0 ° do 360 ° CMC 0,5 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 ° 10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 ° 15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 ° Fázový posuv zrychlení přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, kalibrační systémy snímačů vibrací, referenční generátory přímočarých vibrací Kalibrace – mechanický pohyb Přímé měření laserovým vibrometrem (ČSN ISO 16063-11) 0,2 Hz až 0,4 Hz 0 ° až 360 ° CMC 0,7 ° 0,4 Hz až 5 kHz 0 ° až 360 ° CMC 0,5 ° 5 kHz až 10 kHz 0 ° až 360 ° CMC 1,0 ° 10 kHz až 15 kHz 0 ° až 360 ° CMC 2,0 ° 15 kHz až 20 kHz 0 ° až 360 ° CMC 3,0 ° KP-01 Przesuniecie fazowe przyspieszenia prostoliniowych drgan mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, systemy wzorcowania czujnikow drgan, referencyjne generatory drgan prostoliniowych Wzorcowanie – ruch mechaniczny Pomiar bezposredni wibrometrem laserowym (CSN ISO 16063-11) 0,2 Hz do 0,4 Hz od 0 ° do 360 ° CMC 0,7 ° 0,4 Hz do 5 kHz od 0 ° do 360 ° CMC 0,5 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 ° 10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 ° 15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 ° Fazovy posuv zrychleni primocarych mechanickych vibraci harmonickeho prubehu / Vibrometry, seismometry, kalibracni systemy snimacu vibraci, referencni generatory primocarych vibraci Kalibrace – mechanicky pohyb Prime mereni laserovym vibrometrem (CSN ISO 16063-11) 0,2 Hz az 0,4 Hz 0 ° az 360 ° CMC 0,7 ° 0,4 Hz az 5 kHz 0 ° az 360 ° CMC 0,5 ° 5 kHz az 10 kHz 0 ° az 360 ° CMC 1,0 ° 10 kHz az 15 kHz 0 ° az 360 ° CMC 2,0 ° 15 kHz az 20 kHz 0 ° az 360 ° CMC 3,0 ° KP-01","search_en":"Phase shift of acceleration of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators Calibration – mechanical motion Direct measurement with a laser vibrometer (ČSN ISO 16063-11) 0,2 Hz to 0,4 Hz 0 ° to 360 ° CMC 0,7 ° 0,4 Hz to 5 kHz 0 ° to 360 ° CMC 0,5 ° 5 kHz to 10 kHz 0 ° to 360 ° CMC 1,0 ° 10 kHz to 15 kHz 0 ° to 360 ° CMC 2,0 ° 15 kHz to 20 kHz 0 ° to 360 ° CMC 3,0 ° KP-01","search_zh":"简谐直线机械振动加速度相移 / 测振仪、地震仪、振动传感器校准系统、参考直线振动发生器 校准 – 机械运动 用激光测振仪直接测量（ČSN ISO 16063-11） 0,2 Hz 至 0,4 Hz 0 ° 至 360 ° CMC 0,7 ° 0,4 Hz 至 5 kHz 0 ° 至 360 ° CMC 0,5 ° 5 kHz 至 10 kHz 0 ° 至 360 ° CMC 1,0 ° 10 kHz 至 15 kHz 0 ° 至 360 ° CMC 2,0 ° 15 kHz 至 20 kHz 0 ° 至 360 ° CMC 3,0 ° KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"49f42aa885437fc264f3ea00","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"5","test_object":"Czułość / Czujniki drgań, geofony, wibrometry i tory pomiarowe drgań z wyjściem elektrycznym","test_object_en":"Sensitivity / Vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output","test_object_zh":"灵敏度 / 振动传感器、地震检波器、测振仪及带电输出的振动测量链","test_object_cs":"Citlivost / Snímače vibrací, geofony, vibrometry a měřicí řetězce vibrací s elektrickým výstupem","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 0,4 Hz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"1,5 %"},{"name":"0,4 Hz do 1 Hz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz do 1 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"1 kHz do 5 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"0,7 %"},{"name":"5 kHz do 10 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"1,5 %"},{"name":"10 kHz do 15 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz do 20 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"3,0 %"},{"name":"0,2 Hz do 0,4 Hz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"1,5 %"},{"name":"0,4 Hz do 1 Hz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz do 1 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"1 kHz do 5 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"0,7 %"},{"name":"5 kHz do 10 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"1,5 %"},{"name":"10 kHz do 15 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz do 20 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"3,0 %"},{"name":"0,2 Hz do 0,4 Hz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"1,5 %"},{"name":"0,4 Hz do 1 Hz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"1,0 %"},{"name":"1 Hz do 1 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"1 kHz do 5 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"5 kHz do 10 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"1,5 %"},{"name":"10 kHz do 15 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"2,0 %"},{"name":"15 kHz do 20 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"3,0 %"},{"name":"0,2 Hz do 0,4 Hz","range":"od 0,01 V/m do 10 000 V/m","cmc":"1,5 %"},{"name":"0,4 Hz do 1 Hz","range":"od 0,01 V/m do 10 000 V/m","cmc":"1,0 %"},{"name":"1 Hz do 1 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,5 %"},{"name":"1 kHz do 5 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,7 %"},{"name":"5 kHz do 10 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"1,5 %"},{"name":"10 kHz do 15 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"2,0 %"},{"name":"15 kHz do 20 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"3,0 %"}],"parameters_en":[{"name":"0,2 Hz to 0,4 Hz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"1,5 %"},{"name":"0,4 Hz to 1 Hz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz to 1 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"1 kHz to 5 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"0,7 %"},{"name":"5 kHz to 10 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"1,5 %"},{"name":"10 kHz to 15 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz to 20 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"3,0 %"},{"name":"0,2 Hz to 0,4 Hz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"1,5 %"},{"name":"0,4 Hz to 1 Hz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz to 1 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"1 kHz to 5 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"0,7 %"},{"name":"5 kHz to 10 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"1,5 %"},{"name":"10 kHz to 15 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz to 20 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"3,0 %"},{"name":"0,2 Hz to 0,4 Hz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"1,5 %"},{"name":"0,4 Hz to 1 Hz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"1,0 %"},{"name":"1 Hz to 1 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"1 kHz to 5 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"5 kHz to 10 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"1,5 %"},{"name":"10 kHz to 15 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"2,0 %"},{"name":"15 kHz to 20 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"3,0 %"},{"name":"0,2 Hz to 0,4 Hz","range":"0,01 V/m to 10 000 V/m","cmc":"1,5 %"},{"name":"0,4 Hz to 1 Hz","range":"0,01 V/m to 10 000 V/m","cmc":"1,0 %"},{"name":"1 Hz to 1 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"0,5 %"},{"name":"1 kHz to 5 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"0,7 %"},{"name":"5 kHz to 10 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"1,5 %"},{"name":"10 kHz to 15 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"2,0 %"},{"name":"15 kHz to 20 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"3,0 %"}],"parameters_zh":[{"name":"0,2 Hz 至 0,4 Hz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"1,5 %"},{"name":"0,4 Hz 至 1 Hz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz 至 1 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"1 kHz 至 5 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"0,7 %"},{"name":"5 kHz 至 10 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"1,5 %"},{"name":"10 kHz 至 15 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz 至 20 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"3,0 %"},{"name":"0,2 Hz 至 0,4 Hz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"1,5 %"},{"name":"0,4 Hz 至 1 Hz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz 至 1 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"1 kHz 至 5 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"0,7 %"},{"name":"5 kHz 至 10 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"1,5 %"},{"name":"10 kHz 至 15 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz 至 20 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"3,0 %"},{"name":"0,2 Hz 至 0,4 Hz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"1,5 %"},{"name":"0,4 Hz 至 1 Hz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"1,0 %"},{"name":"1 Hz 至 1 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"1 kHz 至 5 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"5 kHz 至 10 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"1,5 %"},{"name":"10 kHz 至 15 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"2,0 %"},{"name":"15 kHz 至 20 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"3,0 %"},{"name":"0,2 Hz 至 0,4 Hz","range":"0,01 V/m 至 10 000 V/m","cmc":"1,5 %"},{"name":"0,4 Hz 至 1 Hz","range":"0,01 V/m 至 10 000 V/m","cmc":"1,0 %"},{"name":"1 Hz 至 1 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,5 %"},{"name":"1 kHz 至 5 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,7 %"},{"name":"5 kHz 至 10 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"1,5 %"},{"name":"10 kHz 至 15 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"2,0 %"},{"name":"15 kHz 至 20 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"3,0 %"}],"parameters_cs":[{"name":"0,2 Hz až 0,4 Hz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"1,5 %"},{"name":"0,4 Hz až 1 Hz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz až 1 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"1 kHz až 5 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"0,7 %"},{"name":"5 kHz až 10 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"1,5 %"},{"name":"10 kHz až 15 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz až 20 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"3,0 %"},{"name":"0,2 Hz až 0,4 Hz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"1,5 %"},{"name":"0,4 Hz až 1 Hz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"1,0 %"},{"name":"1 Hz až 1 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"1 kHz až 5 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"0,7 %"},{"name":"5 kHz až 10 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"1,5 %"},{"name":"10 kHz až 15 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz až 20 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"3,0 %"},{"name":"0,2 Hz až 0,4 Hz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"1,5 %"},{"name":"0,4 Hz až 1 Hz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"1,0 %"},{"name":"1 Hz až 1 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"1 kHz až 5 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"5 kHz až 10 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"1,5 %"},{"name":"10 kHz až 15 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"2,0 %"},{"name":"15 kHz až 20 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"3,0 %"},{"name":"0,2 Hz až 0,4 Hz","range":"0,01 V/m až 10 000 V/m","cmc":"1,5 %"},{"name":"0,4 Hz až 1 Hz","range":"0,01 V/m až 10 000 V/m","cmc":"1,0 %"},{"name":"1 Hz až 1 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"0,5 %"},{"name":"1 kHz až 5 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"0,7 %"},{"name":"5 kHz až 10 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"1,5 %"},{"name":"10 kHz až 15 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"2,0 %"},{"name":"15 kHz až 20 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"3,0 %"}],"technique":"Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21)","technique_en":"Comparison with a reference sensor (ČSN ISO 16063-21)","technique_zh":"与参考传感器比较（ČSN ISO 16063-21）","technique_cs":"Porovnání s referenčním snímačem (ČSN ISO 16063-21)","techniques":["Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21)"],"techniques_en":["Comparison with a reference sensor (ČSN ISO 16063-21)"],"techniques_zh":["与参考传感器比较（ČSN ISO 16063-21）"],"techniques_cs":["Porovnání s referenčním snímačem (ČSN ISO 16063-21)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 0,4 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,5 %\n0,4 Hz do 1 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,0 %\n1 Hz do 1 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,5 %\n1 kHz do 5 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,7 %\n5 kHz do 10 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,5 %\n10 kHz do 15 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,0 %\n15 kHz do 20 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 3,0 %\n0,2 Hz do 0,4 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,5 %\n0,4 Hz do 1 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,0 %\n1 Hz do 1 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,5 %\n1 kHz do 5 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,7 %\n5 kHz do 10 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,5 %\n10 kHz do 15 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 2,0 %\n15 kHz do 20 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 3,0 %\n0,2 Hz do 0,4 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,5 %\n0,4 Hz do 1 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,0 %\n1 Hz do 1 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 %\n1 kHz do 5 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,7 %\n5 kHz do 10 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,5 %\n10 kHz do 15 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 2,0 %\n15 kHz do 20 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 3,0 %\n0,2 Hz do 0,4 Hz od 0,01 V/m do 10 000 V/m CMC 1,5 %\n0,4 Hz do 1 Hz od 0,01 V/m do 10 000 V/m CMC 1,0 %\n1 Hz do 1 kHz od 0,01 V/m do 10 000 V/m CMC 0,5 %\n1 kHz do 5 kHz od 0,01 V/m do 10 000 V/m CMC 0,7 %\n5 kHz do 10 kHz od 0,01 V/m do 10 000 V/m CMC 1,5 %\n10 kHz do 15 kHz od 0,01 V/m do 10 000 V/m CMC 2,0 %\n15 kHz do 20 kHz od 0,01 V/m do 10 000 V/m CMC 3,0 %\nPorównanie z czujnikiem referencyjnym (ČSN ISO 16063-21)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":"Wielkością wzorcowaną mogą być także prędkość i wychylenie, pod warunkiem wzorcowania sygnałem drgań o przebiegu harmonicznym o znanej częstotliwości. Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻².","note_en":"The calibrated quantities may include also the velocity and deviation, if the calibration is carried out using a harmonic vibration signal of a known frequency. Acceleration can be specified also in g, sensor sensitivity in pC/g, resp. mV/g units, where 1 g = 9.807 m·s⁻².","note_zh":"被校量也可以是速度和位移，前提是使用已知频率的简谐振动信号进行校准。加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²。","note_cs":"Kalibrovanou veličinou mohou být i rychlost a výchylka, za předpokladu kalibrace pomocí vibračního signálu harmonického průběhu na známém kmitočtu. Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻².","search_text":"Czułość / Czujniki drgań, geofony, wibrometry i tory pomiarowe drgań z wyjściem elektrycznym Wzorcowanie – ruch mechaniczny Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21) 0,2 Hz do 0,4 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,5 % 0,4 Hz do 1 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,0 % 1 Hz do 1 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,5 % 1 kHz do 5 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,7 % 5 kHz do 10 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,5 % 10 kHz do 15 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 3,0 % 0,2 Hz do 0,4 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,5 % 0,4 Hz do 1 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,0 % 1 Hz do 1 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,5 % 1 kHz do 5 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,7 % 5 kHz do 10 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,5 % 10 kHz do 15 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 3,0 % 0,2 Hz do 0,4 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,5 % 0,4 Hz do 1 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,0 % 1 Hz do 1 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 % 1 kHz do 5 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,7 % 5 kHz do 10 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,5 % 10 kHz do 15 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz do 20 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 3,0 % 0,2 Hz do 0,4 Hz od 0,01 V/m do 10 000 V/m CMC 1,5 % 0,4 Hz do 1 Hz od 0,01 V/m do 10 000 V/m CMC 1,0 % 1 Hz do 1 kHz od 0,01 V/m do 10 000 V/m CMC 0,5 % 1 kHz do 5 kHz od 0,01 V/m do 10 000 V/m CMC 0,7 % 5 kHz do 10 kHz od 0,01 V/m do 10 000 V/m CMC 1,5 % 10 kHz do 15 kHz od 0,01 V/m do 10 000 V/m CMC 2,0 % 15 kHz do 20 kHz od 0,01 V/m do 10 000 V/m CMC 3,0 % Citlivost / Snímače vibrací, geofony, vibrometry a měřicí řetězce vibrací s elektrickým výstupem Kalibrace – mechanický pohyb Porovnání s referenčním snímačem (ČSN ISO 16063-21) 0,2 Hz až 0,4 Hz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 1,5 % 0,4 Hz až 1 Hz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 1,0 % 1 Hz až 1 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 0,5 % 1 kHz až 5 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 0,7 % 5 kHz až 10 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 1,5 % 10 kHz až 15 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz až 20 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 3,0 % 0,2 Hz až 0,4 Hz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 1,5 % 0,4 Hz až 1 Hz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 1,0 % 1 Hz až 1 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 0,5 % 1 kHz až 5 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 0,7 % 5 kHz až 10 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 1,5 % 10 kHz až 15 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 2,0 % 15 kHz až 20 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 3,0 % 0,2 Hz až 0,4 Hz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 1,5 % 0,4 Hz až 1 Hz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 1,0 % 1 Hz až 1 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,5 % 1 kHz až 5 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,7 % 5 kHz až 10 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 1,5 % 10 kHz až 15 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz až 20 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 3,0 % 0,2 Hz až 0,4 Hz 0,01 V/m až 10 000 V/m CMC 1,5 % 0,4 Hz až 1 Hz 0,01 V/m až 10 000 V/m CMC 1,0 % 1 Hz až 1 kHz 0,01 V/m až 10 000 V/m CMC 0,5 % 1 kHz až 5 kHz 0,01 V/m až 10 000 V/m CMC 0,7 % 5 kHz až 10 kHz 0,01 V/m až 10 000 V/m CMC 1,5 % 10 kHz až 15 kHz 0,01 V/m až 10 000 V/m CMC 2,0 % 15 kHz až 20 kHz 0,01 V/m až 10 000 V/m CMC 3,0 % KP-01 Czulosc / Czujniki drgan, geofony, wibrometry i tory pomiarowe drgan z wyjsciem elektrycznym Wzorcowanie – ruch mechaniczny Porownanie z czujnikiem referencyjnym (CSN ISO 16063-21) 0,2 Hz do 0,4 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,5 % 0,4 Hz do 1 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,0 % 1 Hz do 1 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,5 % 1 kHz do 5 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,7 % 5 kHz do 10 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,5 % 10 kHz do 15 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 3,0 % 0,2 Hz do 0,4 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,5 % 0,4 Hz do 1 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,0 % 1 Hz do 1 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,5 % 1 kHz do 5 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,7 % 5 kHz do 10 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,5 % 10 kHz do 15 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 3,0 % 0,2 Hz do 0,4 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,5 % 0,4 Hz do 1 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,0 % 1 Hz do 1 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 % 1 kHz do 5 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,7 % 5 kHz do 10 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,5 % 10 kHz do 15 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz do 20 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 3,0 % 0,2 Hz do 0,4 Hz od 0,01 V/m do 10 000 V/m CMC 1,5 % 0,4 Hz do 1 Hz od 0,01 V/m do 10 000 V/m CMC 1,0 % 1 Hz do 1 kHz od 0,01 V/m do 10 000 V/m CMC 0,5 % 1 kHz do 5 kHz od 0,01 V/m do 10 000 V/m CMC 0,7 % 5 kHz do 10 kHz od 0,01 V/m do 10 000 V/m CMC 1,5 % 10 kHz do 15 kHz od 0,01 V/m do 10 000 V/m CMC 2,0 % 15 kHz do 20 kHz od 0,01 V/m do 10 000 V/m CMC 3,0 % Citlivost / Snimace vibraci, geofony, vibrometry a merici retezce vibraci s elektrickym vystupem Kalibrace – mechanicky pohyb Porovnani s referencnim snimacem (CSN ISO 16063-21) 0,2 Hz az 0,4 Hz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 1,5 % 0,4 Hz az 1 Hz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 1,0 % 1 Hz az 1 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 0,5 % 1 kHz az 5 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 0,7 % 5 kHz az 10 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 1,5 % 10 kHz az 15 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz az 20 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 3,0 % 0,2 Hz az 0,4 Hz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 1,5 % 0,4 Hz az 1 Hz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 1,0 % 1 Hz az 1 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 0,5 % 1 kHz az 5 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 0,7 % 5 kHz az 10 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 1,5 % 10 kHz az 15 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 2,0 % 15 kHz az 20 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 3,0 % 0,2 Hz az 0,4 Hz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 1,5 % 0,4 Hz az 1 Hz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 1,0 % 1 Hz az 1 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,5 % 1 kHz az 5 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,7 % 5 kHz az 10 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 1,5 % 10 kHz az 15 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz az 20 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 3,0 % 0,2 Hz az 0,4 Hz 0,01 V/m az 10 000 V/m CMC 1,5 % 0,4 Hz az 1 Hz 0,01 V/m az 10 000 V/m CMC 1,0 % 1 Hz az 1 kHz 0,01 V/m az 10 000 V/m CMC 0,5 % 1 kHz az 5 kHz 0,01 V/m az 10 000 V/m CMC 0,7 % 5 kHz az 10 kHz 0,01 V/m az 10 000 V/m CMC 1,5 % 10 kHz az 15 kHz 0,01 V/m az 10 000 V/m CMC 2,0 % 15 kHz az 20 kHz 0,01 V/m az 10 000 V/m CMC 3,0 % KP-01","search_en":"Sensitivity / Vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output Calibration – mechanical motion Comparison with a reference sensor (ČSN ISO 16063-21) 0,2 Hz to 0,4 Hz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 1,5 % 0,4 Hz to 1 Hz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 1,0 % 1 Hz to 1 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 0,5 % 1 kHz to 5 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 0,7 % 5 kHz to 10 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 1,5 % 10 kHz to 15 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz to 20 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 3,0 % 0,2 Hz to 0,4 Hz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 1,5 % 0,4 Hz to 1 Hz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 1,0 % 1 Hz to 1 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 0,5 % 1 kHz to 5 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 0,7 % 5 kHz to 10 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 1,5 % 10 kHz to 15 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 2,0 % 15 kHz to 20 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 3,0 % 0,2 Hz to 0,4 Hz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 1,5 % 0,4 Hz to 1 Hz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 1,0 % 1 Hz to 1 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,5 % 1 kHz to 5 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,7 % 5 kHz to 10 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 1,5 % 10 kHz to 15 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz to 20 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 3,0 % 0,2 Hz to 0,4 Hz 0,01 V/m to 10 000 V/m CMC 1,5 % 0,4 Hz to 1 Hz 0,01 V/m to 10 000 V/m CMC 1,0 % 1 Hz to 1 kHz 0,01 V/m to 10 000 V/m CMC 0,5 % 1 kHz to 5 kHz 0,01 V/m to 10 000 V/m CMC 0,7 % 5 kHz to 10 kHz 0,01 V/m to 10 000 V/m CMC 1,5 % 10 kHz to 15 kHz 0,01 V/m to 10 000 V/m CMC 2,0 % 15 kHz to 20 kHz 0,01 V/m to 10 000 V/m CMC 3,0 % KP-01","search_zh":"灵敏度 / 振动传感器、地震检波器、测振仪及带电输出的振动测量链 校准 – 机械运动 与参考传感器比较（ČSN ISO 16063-21） 0,2 Hz 至 0,4 Hz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 1,5 % 0,4 Hz 至 1 Hz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 1,0 % 1 Hz 至 1 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 0,5 % 1 kHz 至 5 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 0,7 % 5 kHz 至 10 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 1,5 % 10 kHz 至 15 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz 至 20 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 3,0 % 0,2 Hz 至 0,4 Hz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 1,5 % 0,4 Hz 至 1 Hz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 1,0 % 1 Hz 至 1 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 0,5 % 1 kHz 至 5 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 0,7 % 5 kHz 至 10 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 1,5 % 10 kHz 至 15 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 2,0 % 15 kHz 至 20 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 3,0 % 0,2 Hz 至 0,4 Hz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 1,5 % 0,4 Hz 至 1 Hz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 1,0 % 1 Hz 至 1 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,5 % 1 kHz 至 5 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,7 % 5 kHz 至 10 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 1,5 % 10 kHz 至 15 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz 至 20 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 3,0 % 0,2 Hz 至 0,4 Hz 0,01 V/m 至 10 000 V/m CMC 1,5 % 0,4 Hz 至 1 Hz 0,01 V/m 至 10 000 V/m CMC 1,0 % 1 Hz 至 1 kHz 0,01 V/m 至 10 000 V/m CMC 0,5 % 1 kHz 至 5 kHz 0,01 V/m 至 10 000 V/m CMC 0,7 % 5 kHz 至 10 kHz 0,01 V/m 至 10 000 V/m CMC 1,5 % 10 kHz 至 15 kHz 0,01 V/m 至 10 000 V/m CMC 2,0 % 15 kHz 至 20 kHz 0,01 V/m 至 10 000 V/m CMC 3,0 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"68b82fa4a23a6bf483fbd298","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"6","test_object":"Czułość / Czujniki drgań, wzorcowe czujniki drgań, geofony, wibrometry i tory pomiarowe drgań z wyjściem elektrycznym","test_object_en":"Sensitivity / Vibration transducers, standard vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output","test_object_zh":"灵敏度 / 振动传感器、标准振动传感器、地震检波器、测振仪及带电输出的振动测量链","test_object_cs":"Citlivost / Snímače vibrací, etalonové snímače vibrací, geofony, vibrometry a měřicí řetězce vibrací s elektrickým výstupem","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 0,4 Hz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz do 1 Hz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz do 1 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz do 5 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz do 10 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz do 15 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz do 20 kHz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"2,5 %"},{"name":"0,2 Hz do 0,4 Hz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz do 1 Hz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz do 1 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz do 5 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz do 10 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz do 15 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz do 20 kHz","range":"od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻²","cmc":"2,5 %"},{"name":"0,2 Hz do 0,4 Hz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"0,4 Hz do 1 Hz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"1 Hz do 1 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,3 %"},{"name":"1 kHz do 5 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"5 kHz do 10 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"1,0 %"},{"name":"10 kHz do 15 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"2,0 %"},{"name":"15 kHz do 20 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"2,5 %"},{"name":"0,2 Hz do 0,4 Hz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,7 %"},{"name":"0,4 Hz do 1 Hz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,5 %"},{"name":"1 Hz do 1 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,3 %"},{"name":"1 kHz do 5 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,5 %"},{"name":"5 kHz do 10 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"1,0 %"},{"name":"10 kHz do 15 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"2,0 %"},{"name":"15 kHz do 20 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"2,5 %"}],"parameters_en":[{"name":"0,2 Hz to 0,4 Hz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz to 1 Hz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz to 1 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz to 5 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz to 10 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz to 15 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz to 20 kHz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"2,5 %"},{"name":"0,2 Hz to 0,4 Hz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz to 1 Hz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz to 1 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz to 5 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz to 10 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz to 15 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz to 20 kHz","range":"0,01 pC/m·s⁻² to 1000 pC/m·s⁻²","cmc":"2,5 %"},{"name":"0,2 Hz to 0,4 Hz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"0,4 Hz to 1 Hz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"1 Hz to 1 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,3 %"},{"name":"1 kHz to 5 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"5 kHz to 10 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"1,0 %"},{"name":"10 kHz to 15 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"2,0 %"},{"name":"15 kHz to 20 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"2,5 %"},{"name":"0,2 Hz to 0,4 Hz","range":"0,01 V/m to 10 000 V/m","cmc":"0,7 %"},{"name":"0,4 Hz to 1 Hz","range":"0,01 V/m to 10 000 V/m","cmc":"0,5 %"},{"name":"1 Hz to 1 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"0,3 %"},{"name":"1 kHz to 5 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"0,5 %"},{"name":"5 kHz to 10 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"1,0 %"},{"name":"10 kHz to 15 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"2,0 %"},{"name":"15 kHz to 20 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"2,5 %"}],"parameters_zh":[{"name":"0,2 Hz 至 0,4 Hz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz 至 1 Hz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz 至 1 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz 至 5 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz 至 10 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz 至 15 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz 至 20 kHz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"2,5 %"},{"name":"0,2 Hz 至 0,4 Hz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz 至 1 Hz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz 至 1 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz 至 5 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz 至 10 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz 至 15 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz 至 20 kHz","range":"0,01 pC/m·s⁻² 至 1000 pC/m·s⁻²","cmc":"2,5 %"},{"name":"0,2 Hz 至 0,4 Hz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"0,4 Hz 至 1 Hz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"1 Hz 至 1 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,3 %"},{"name":"1 kHz 至 5 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"5 kHz 至 10 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"1,0 %"},{"name":"10 kHz 至 15 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"2,0 %"},{"name":"15 kHz 至 20 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"2,5 %"},{"name":"0,2 Hz 至 0,4 Hz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,7 %"},{"name":"0,4 Hz 至 1 Hz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,5 %"},{"name":"1 Hz 至 1 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,3 %"},{"name":"1 kHz 至 5 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,5 %"},{"name":"5 kHz 至 10 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"1,0 %"},{"name":"10 kHz 至 15 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"2,0 %"},{"name":"15 kHz 至 20 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"2,5 %"}],"parameters_cs":[{"name":"0,2 Hz až 0,4 Hz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz až 1 Hz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz až 1 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz až 5 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz až 10 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz až 15 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz až 20 kHz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"2,5 %"},{"name":"0,2 Hz až 0,4 Hz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"0,7 %"},{"name":"0,4 Hz až 1 Hz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"1 Hz až 1 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"0,3 %"},{"name":"1 kHz až 5 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"0,5 %"},{"name":"5 kHz až 10 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"1,0 %"},{"name":"10 kHz až 15 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"2,0 %"},{"name":"15 kHz až 20 kHz","range":"0,01 pC/m·s⁻² až 1000 pC/m·s⁻²","cmc":"2,5 %"},{"name":"0,2 Hz až 0,4 Hz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"0,4 Hz až 1 Hz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"1 Hz až 1 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,3 %"},{"name":"1 kHz až 5 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"5 kHz až 10 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"1,0 %"},{"name":"10 kHz až 15 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"2,0 %"},{"name":"15 kHz až 20 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"2,5 %"},{"name":"0,2 Hz až 0,4 Hz","range":"0,01 V/m až 10 000 V/m","cmc":"0,7 %"},{"name":"0,4 Hz až 1 Hz","range":"0,01 V/m až 10 000 V/m","cmc":"0,5 %"},{"name":"1 Hz až 1 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"0,3 %"},{"name":"1 kHz až 5 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"0,5 %"},{"name":"5 kHz až 10 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"1,0 %"},{"name":"10 kHz až 15 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"2,0 %"},{"name":"15 kHz až 20 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"2,5 %"}],"technique":"Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11)","technique_en":"Direct measurement with a laser vibrometer (ČSN ISO 16063-11)","technique_zh":"用激光测振仪直接测量（ČSN ISO 16063-11）","technique_cs":"Přímé měření laserovým vibrometrem (ČSN ISO 16063-11)","techniques":["Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11)"],"techniques_en":["Direct measurement with a laser vibrometer (ČSN ISO 16063-11)"],"techniques_zh":["用激光测振仪直接测量（ČSN ISO 16063-11）"],"techniques_cs":["Přímé měření laserovým vibrometrem (ČSN ISO 16063-11)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 0,4 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,7 %\n0,4 Hz do 1 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,5 %\n1 Hz do 1 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,3 %\n1 kHz do 5 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,5 %\n5 kHz do 10 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,0 %\n10 kHz do 15 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,0 %\n15 kHz do 20 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,5 %\n0,2 Hz do 0,4 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,7 %\n0,4 Hz do 1 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,5 %\n1 Hz do 1 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,3 %\n1 kHz do 5 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,5 %\n5 kHz do 10 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,0 %\n10 kHz do 15 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 2,0 %\n15 kHz do 20 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 2,5 %\n0,2 Hz do 0,4 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,7 %\n0,4 Hz do 1 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 %\n1 Hz do 1 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,3 %\n1 kHz do 5 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 %\n5 kHz do 10 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,0 %\n10 kHz do 15 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 2,0 %\n15 kHz do 20 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 2,5 %\n0,2 Hz do 0,4 Hz od 0,01 V/m do 10 000 V/m CMC 0,7 %\n0,4 Hz do 1 Hz od 0,01 V/m do 10 000 V/m CMC 0,5 %\n1 Hz do 1 kHz od 0,01 V/m do 10 000 V/m CMC 0,3 %\n1 kHz do 5 kHz od 0,01 V/m do 10 000 V/m CMC 0,5 %\n5 kHz do 10 kHz od 0,01 V/m do 10 000 V/m CMC 1,0 %\n10 kHz do 15 kHz od 0,01 V/m do 10 000 V/m CMC 2,0 %\n15 kHz do 20 kHz od 0,01 V/m do 10 000 V/m CMC 2,5 %\nPomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością wzorcowaną mogą być także prędkość i wychylenie, pod warunkiem wzorcowania sygnałem drgań o przebiegu harmonicznym o znanej częstotliwości. Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻².","note_en":"The calibrated quantities may include also the velocity and deviation, if the calibration is carried out using a harmonic vibration signal of a known frequency. Acceleration can be specified also in g, sensor sensitivity in pC/g, resp. mV/g units, where 1 g = 9.807 m·s⁻².","note_zh":"被校量也可以是速度和位移，前提是使用已知频率的简谐振动信号进行校准。加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²。","note_cs":"Kalibrovanou veličinou mohou být i rychlost a výchylka, za předpokladu kalibrace pomocí vibračního signálu harmonického průběhu na známém kmitočtu. Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻².","search_text":"Czułość / Czujniki drgań, wzorcowe czujniki drgań, geofony, wibrometry i tory pomiarowe drgań z wyjściem elektrycznym Wzorcowanie – ruch mechaniczny Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11) 0,2 Hz do 0,4 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,7 % 0,4 Hz do 1 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,5 % 1 Hz do 1 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,3 % 1 kHz do 5 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,5 % 5 kHz do 10 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,0 % 10 kHz do 15 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,5 % 0,2 Hz do 0,4 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,7 % 0,4 Hz do 1 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,5 % 1 Hz do 1 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,3 % 1 kHz do 5 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,5 % 5 kHz do 10 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,0 % 10 kHz do 15 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 2,5 % 0,2 Hz do 0,4 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,7 % 0,4 Hz do 1 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 % 1 Hz do 1 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,3 % 1 kHz do 5 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 % 5 kHz do 10 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,0 % 10 kHz do 15 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz do 20 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 2,5 % 0,2 Hz do 0,4 Hz od 0,01 V/m do 10 000 V/m CMC 0,7 % 0,4 Hz do 1 Hz od 0,01 V/m do 10 000 V/m CMC 0,5 % 1 Hz do 1 kHz od 0,01 V/m do 10 000 V/m CMC 0,3 % 1 kHz do 5 kHz od 0,01 V/m do 10 000 V/m CMC 0,5 % 5 kHz do 10 kHz od 0,01 V/m do 10 000 V/m CMC 1,0 % 10 kHz do 15 kHz od 0,01 V/m do 10 000 V/m CMC 2,0 % 15 kHz do 20 kHz od 0,01 V/m do 10 000 V/m CMC 2,5 % Citlivost / Snímače vibrací, etalonové snímače vibrací, geofony, vibrometry a měřicí řetězce vibrací s elektrickým výstupem Kalibrace – mechanický pohyb Přímé měření laserovým vibrometrem (ČSN ISO 16063-11) 0,2 Hz až 0,4 Hz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 0,7 % 0,4 Hz až 1 Hz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 0,5 % 1 Hz až 1 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 0,3 % 1 kHz až 5 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 0,5 % 5 kHz až 10 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 1,0 % 10 kHz až 15 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz až 20 kHz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 2,5 % 0,2 Hz až 0,4 Hz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 0,7 % 0,4 Hz až 1 Hz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 0,5 % 1 Hz až 1 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 0,3 % 1 kHz až 5 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 0,5 % 5 kHz až 10 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 1,0 % 10 kHz až 15 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 2,0 % 15 kHz až 20 kHz 0,01 pC/m·s⁻² až 1000 pC/m·s⁻² CMC 2,5 % 0,2 Hz až 0,4 Hz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,7 % 0,4 Hz až 1 Hz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,5 % 1 Hz až 1 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,3 % 1 kHz až 5 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,5 % 5 kHz až 10 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 1,0 % 10 kHz až 15 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz až 20 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 2,5 % 0,2 Hz až 0,4 Hz 0,01 V/m až 10 000 V/m CMC 0,7 % 0,4 Hz až 1 Hz 0,01 V/m až 10 000 V/m CMC 0,5 % 1 Hz až 1 kHz 0,01 V/m až 10 000 V/m CMC 0,3 % 1 kHz až 5 kHz 0,01 V/m až 10 000 V/m CMC 0,5 % 5 kHz až 10 kHz 0,01 V/m až 10 000 V/m CMC 1,0 % 10 kHz až 15 kHz 0,01 V/m až 10 000 V/m CMC 2,0 % 15 kHz až 20 kHz 0,01 V/m až 10 000 V/m CMC 2,5 % KP-01 Czulosc / Czujniki drgan, wzorcowe czujniki drgan, geofony, wibrometry i tory pomiarowe drgan z wyjsciem elektrycznym Wzorcowanie – ruch mechaniczny Pomiar bezposredni wibrometrem laserowym (CSN ISO 16063-11) 0,2 Hz do 0,4 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,7 % 0,4 Hz do 1 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,5 % 1 Hz do 1 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,3 % 1 kHz do 5 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 0,5 % 5 kHz do 10 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 1,0 % 10 kHz do 15 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,5 % 0,2 Hz do 0,4 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,7 % 0,4 Hz do 1 Hz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,5 % 1 Hz do 1 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,3 % 1 kHz do 5 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 0,5 % 5 kHz do 10 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 1,0 % 10 kHz do 15 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 2,0 % 15 kHz do 20 kHz od 0,01 pC/m·s⁻² do 1000 pC/m·s⁻² CMC 2,5 % 0,2 Hz do 0,4 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,7 % 0,4 Hz do 1 Hz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 % 1 Hz do 1 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,3 % 1 kHz do 5 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 % 5 kHz do 10 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 1,0 % 10 kHz do 15 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz do 20 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 2,5 % 0,2 Hz do 0,4 Hz od 0,01 V/m do 10 000 V/m CMC 0,7 % 0,4 Hz do 1 Hz od 0,01 V/m do 10 000 V/m CMC 0,5 % 1 Hz do 1 kHz od 0,01 V/m do 10 000 V/m CMC 0,3 % 1 kHz do 5 kHz od 0,01 V/m do 10 000 V/m CMC 0,5 % 5 kHz do 10 kHz od 0,01 V/m do 10 000 V/m CMC 1,0 % 10 kHz do 15 kHz od 0,01 V/m do 10 000 V/m CMC 2,0 % 15 kHz do 20 kHz od 0,01 V/m do 10 000 V/m CMC 2,5 % Citlivost / Snimace vibraci, etalonove snimace vibraci, geofony, vibrometry a merici retezce vibraci s elektrickym vystupem Kalibrace – mechanicky pohyb Prime mereni laserovym vibrometrem (CSN ISO 16063-11) 0,2 Hz az 0,4 Hz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 0,7 % 0,4 Hz az 1 Hz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 0,5 % 1 Hz az 1 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 0,3 % 1 kHz az 5 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 0,5 % 5 kHz az 10 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 1,0 % 10 kHz az 15 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz az 20 kHz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 2,5 % 0,2 Hz az 0,4 Hz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 0,7 % 0,4 Hz az 1 Hz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 0,5 % 1 Hz az 1 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 0,3 % 1 kHz az 5 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 0,5 % 5 kHz az 10 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 1,0 % 10 kHz az 15 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 2,0 % 15 kHz az 20 kHz 0,01 pC/m·s⁻² az 1000 pC/m·s⁻² CMC 2,5 % 0,2 Hz az 0,4 Hz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,7 % 0,4 Hz az 1 Hz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,5 % 1 Hz az 1 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,3 % 1 kHz az 5 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,5 % 5 kHz az 10 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 1,0 % 10 kHz az 15 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz az 20 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 2,5 % 0,2 Hz az 0,4 Hz 0,01 V/m az 10 000 V/m CMC 0,7 % 0,4 Hz az 1 Hz 0,01 V/m az 10 000 V/m CMC 0,5 % 1 Hz az 1 kHz 0,01 V/m az 10 000 V/m CMC 0,3 % 1 kHz az 5 kHz 0,01 V/m az 10 000 V/m CMC 0,5 % 5 kHz az 10 kHz 0,01 V/m az 10 000 V/m CMC 1,0 % 10 kHz az 15 kHz 0,01 V/m az 10 000 V/m CMC 2,0 % 15 kHz az 20 kHz 0,01 V/m az 10 000 V/m CMC 2,5 % KP-01","search_en":"Sensitivity / Vibration transducers, standard vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output Calibration – mechanical motion Direct measurement with a laser vibrometer (ČSN ISO 16063-11) 0,2 Hz to 0,4 Hz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 0,7 % 0,4 Hz to 1 Hz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 0,5 % 1 Hz to 1 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 0,3 % 1 kHz to 5 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 0,5 % 5 kHz to 10 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 1,0 % 10 kHz to 15 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz to 20 kHz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 2,5 % 0,2 Hz to 0,4 Hz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 0,7 % 0,4 Hz to 1 Hz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 0,5 % 1 Hz to 1 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 0,3 % 1 kHz to 5 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 0,5 % 5 kHz to 10 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 1,0 % 10 kHz to 15 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 2,0 % 15 kHz to 20 kHz 0,01 pC/m·s⁻² to 1000 pC/m·s⁻² CMC 2,5 % 0,2 Hz to 0,4 Hz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,7 % 0,4 Hz to 1 Hz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,5 % 1 Hz to 1 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,3 % 1 kHz to 5 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,5 % 5 kHz to 10 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 1,0 % 10 kHz to 15 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz to 20 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 2,5 % 0,2 Hz to 0,4 Hz 0,01 V/m to 10 000 V/m CMC 0,7 % 0,4 Hz to 1 Hz 0,01 V/m to 10 000 V/m CMC 0,5 % 1 Hz to 1 kHz 0,01 V/m to 10 000 V/m CMC 0,3 % 1 kHz to 5 kHz 0,01 V/m to 10 000 V/m CMC 0,5 % 5 kHz to 10 kHz 0,01 V/m to 10 000 V/m CMC 1,0 % 10 kHz to 15 kHz 0,01 V/m to 10 000 V/m CMC 2,0 % 15 kHz to 20 kHz 0,01 V/m to 10 000 V/m CMC 2,5 % KP-01","search_zh":"灵敏度 / 振动传感器、标准振动传感器、地震检波器、测振仪及带电输出的振动测量链 校准 – 机械运动 用激光测振仪直接测量（ČSN ISO 16063-11） 0,2 Hz 至 0,4 Hz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 0,7 % 0,4 Hz 至 1 Hz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 0,5 % 1 Hz 至 1 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 0,3 % 1 kHz 至 5 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 0,5 % 5 kHz 至 10 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 1,0 % 10 kHz 至 15 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 2,0 % 15 kHz 至 20 kHz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 2,5 % 0,2 Hz 至 0,4 Hz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 0,7 % 0,4 Hz 至 1 Hz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 0,5 % 1 Hz 至 1 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 0,3 % 1 kHz 至 5 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 0,5 % 5 kHz 至 10 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 1,0 % 10 kHz 至 15 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 2,0 % 15 kHz 至 20 kHz 0,01 pC/m·s⁻² 至 1000 pC/m·s⁻² CMC 2,5 % 0,2 Hz 至 0,4 Hz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,7 % 0,4 Hz 至 1 Hz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,5 % 1 Hz 至 1 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,3 % 1 kHz 至 5 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,5 % 5 kHz 至 10 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 1,0 % 10 kHz 至 15 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 2,0 % 15 kHz 至 20 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 2,5 % 0,2 Hz 至 0,4 Hz 0,01 V/m 至 10 000 V/m CMC 0,7 % 0,4 Hz 至 1 Hz 0,01 V/m 至 10 000 V/m CMC 0,5 % 1 Hz 至 1 kHz 0,01 V/m 至 10 000 V/m CMC 0,3 % 1 kHz 至 5 kHz 0,01 V/m 至 10 000 V/m CMC 0,5 % 5 kHz 至 10 kHz 0,01 V/m 至 10 000 V/m CMC 1,0 % 10 kHz 至 15 kHz 0,01 V/m 至 10 000 V/m CMC 2,0 % 15 kHz 至 20 kHz 0,01 V/m 至 10 000 V/m CMC 2,5 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"46f558685e3aaf2115083b18","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"7","test_object":"Czułość / Wibrometry laserowe z wyjściem elektrycznym","test_object_en":"Sensitivity / Laser vibrometers with an electric output","test_object_zh":"灵敏度 / 带电输出的激光测振仪","test_object_cs":"Citlivost / Laserové vibrometry s elektrickým výstupem","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 5 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,25 %"},{"name":"5 kHz do 10 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,3 %"},{"name":"10 kHz do 15 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"15 kHz do 20 kHz","range":"od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"0,2 Hz do 5 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,25 %"},{"name":"5 kHz do 10 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,3 %"},{"name":"10 kHz do 15 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,5 %"},{"name":"15 kHz do 20 kHz","range":"od 0,01 V/m do 10 000 V/m","cmc":"0,7 %"}],"parameters_en":[{"name":"0,2 Hz to 5 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,25 %"},{"name":"5 kHz to 10 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,3 %"},{"name":"10 kHz to 15 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"15 kHz to 20 kHz","range":"0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"0,2 Hz to 5 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"0,25 %"},{"name":"5 kHz to 10 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"0,3 %"},{"name":"10 kHz to 15 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"0,5 %"},{"name":"15 kHz to 20 kHz","range":"0,01 V/m to 10 000 V/m","cmc":"0,7 %"}],"parameters_zh":[{"name":"0,2 Hz 至 5 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,25 %"},{"name":"5 kHz 至 10 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,3 %"},{"name":"10 kHz 至 15 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"15 kHz 至 20 kHz","range":"0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"0,2 Hz 至 5 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,25 %"},{"name":"5 kHz 至 10 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,3 %"},{"name":"10 kHz 至 15 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,5 %"},{"name":"15 kHz 至 20 kHz","range":"0,01 V/m 至 10 000 V/m","cmc":"0,7 %"}],"parameters_cs":[{"name":"0,2 Hz až 5 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,25 %"},{"name":"5 kHz až 10 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,3 %"},{"name":"10 kHz až 15 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,5 %"},{"name":"15 kHz až 20 kHz","range":"0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹","cmc":"0,7 %"},{"name":"0,2 Hz až 5 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"0,25 %"},{"name":"5 kHz až 10 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"0,3 %"},{"name":"10 kHz až 15 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"0,5 %"},{"name":"15 kHz až 20 kHz","range":"0,01 V/m až 10 000 V/m","cmc":"0,7 %"}],"technique":"Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-41)","technique_en":"Direct measurement with a laser vibrometer (ČSN ISO 16063-41)","technique_zh":"用激光测振仪直接测量（ČSN ISO 16063-41）","technique_cs":"Přímé měření laserovým vibrometrem (ČSN ISO 16063-41)","techniques":["Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-41)"],"techniques_en":["Direct measurement with a laser vibrometer (ČSN ISO 16063-41)"],"techniques_zh":["用激光测振仪直接测量（ČSN ISO 16063-41）"],"techniques_cs":["Přímé měření laserovým vibrometrem (ČSN ISO 16063-41)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 5 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,25 %\n5 kHz do 10 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,3 %\n10 kHz do 15 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 %\n15 kHz do 20 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,7 %\n0,2 Hz do 5 kHz od 0,01 V/m do 10 000 V/m CMC 0,25 %\n5 kHz do 10 kHz od 0,01 V/m do 10 000 V/m CMC 0,3 %\n10 kHz do 15 kHz od 0,01 V/m do 10 000 V/m CMC 0,5 %\n15 kHz do 20 kHz od 0,01 V/m do 10 000 V/m CMC 0,7 %\nPomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-41)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością wzorcowaną mogą być także prędkość i wychylenie, pod warunkiem wzorcowania sygnałem drgań o przebiegu harmonicznym o znanej częstotliwości. Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻².","note_en":"The calibrated quantities may include also the velocity and deviation, if the calibration is carried out using a harmonic vibration signal of a known frequency. Acceleration can be specified also in g, sensor sensitivity in pC/g, resp. mV/g units, where 1 g = 9.807 m·s⁻².","note_zh":"被校量也可以是速度和位移，前提是使用已知频率的简谐振动信号进行校准。加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²。","note_cs":"Kalibrovanou veličinou mohou být i rychlost a výchylka, za předpokladu kalibrace pomocí vibračního signálu harmonického průběhu na známém kmitočtu. Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻².","search_text":"Czułość / Wibrometry laserowe z wyjściem elektrycznym Wzorcowanie – ruch mechaniczny Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-41) 0,2 Hz do 5 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,25 % 5 kHz do 10 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,3 % 10 kHz do 15 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 % 15 kHz do 20 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,7 % 0,2 Hz do 5 kHz od 0,01 V/m do 10 000 V/m CMC 0,25 % 5 kHz do 10 kHz od 0,01 V/m do 10 000 V/m CMC 0,3 % 10 kHz do 15 kHz od 0,01 V/m do 10 000 V/m CMC 0,5 % 15 kHz do 20 kHz od 0,01 V/m do 10 000 V/m CMC 0,7 % Citlivost / Laserové vibrometry s elektrickým výstupem Kalibrace – mechanický pohyb Přímé měření laserovým vibrometrem (ČSN ISO 16063-41) 0,2 Hz až 5 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,25 % 5 kHz až 10 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,3 % 10 kHz až 15 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,5 % 15 kHz až 20 kHz 0,1 V/m·s⁻¹ až 10 000 V/m·s⁻¹ CMC 0,7 % 0,2 Hz až 5 kHz 0,01 V/m až 10 000 V/m CMC 0,25 % 5 kHz až 10 kHz 0,01 V/m až 10 000 V/m CMC 0,3 % 10 kHz až 15 kHz 0,01 V/m až 10 000 V/m CMC 0,5 % 15 kHz až 20 kHz 0,01 V/m až 10 000 V/m CMC 0,7 % KP-01 Czulosc / Wibrometry laserowe z wyjsciem elektrycznym Wzorcowanie – ruch mechaniczny Pomiar bezposredni wibrometrem laserowym (CSN ISO 16063-41) 0,2 Hz do 5 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,25 % 5 kHz do 10 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,3 % 10 kHz do 15 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,5 % 15 kHz do 20 kHz od 0,1 V/m·s⁻¹ do 10 000 V/m·s⁻¹ CMC 0,7 % 0,2 Hz do 5 kHz od 0,01 V/m do 10 000 V/m CMC 0,25 % 5 kHz do 10 kHz od 0,01 V/m do 10 000 V/m CMC 0,3 % 10 kHz do 15 kHz od 0,01 V/m do 10 000 V/m CMC 0,5 % 15 kHz do 20 kHz od 0,01 V/m do 10 000 V/m CMC 0,7 % Citlivost / Laserove vibrometry s elektrickym vystupem Kalibrace – mechanicky pohyb Prime mereni laserovym vibrometrem (CSN ISO 16063-41) 0,2 Hz az 5 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,25 % 5 kHz az 10 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,3 % 10 kHz az 15 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,5 % 15 kHz az 20 kHz 0,1 V/m·s⁻¹ az 10 000 V/m·s⁻¹ CMC 0,7 % 0,2 Hz az 5 kHz 0,01 V/m az 10 000 V/m CMC 0,25 % 5 kHz az 10 kHz 0,01 V/m az 10 000 V/m CMC 0,3 % 10 kHz az 15 kHz 0,01 V/m az 10 000 V/m CMC 0,5 % 15 kHz az 20 kHz 0,01 V/m az 10 000 V/m CMC 0,7 % KP-01","search_en":"Sensitivity / Laser vibrometers with an electric output Calibration – mechanical motion Direct measurement with a laser vibrometer (ČSN ISO 16063-41) 0,2 Hz to 5 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,25 % 5 kHz to 10 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,3 % 10 kHz to 15 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,5 % 15 kHz to 20 kHz 0,1 V/m·s⁻¹ to 10 000 V/m·s⁻¹ CMC 0,7 % 0,2 Hz to 5 kHz 0,01 V/m to 10 000 V/m CMC 0,25 % 5 kHz to 10 kHz 0,01 V/m to 10 000 V/m CMC 0,3 % 10 kHz to 15 kHz 0,01 V/m to 10 000 V/m CMC 0,5 % 15 kHz to 20 kHz 0,01 V/m to 10 000 V/m CMC 0,7 % KP-01","search_zh":"灵敏度 / 带电输出的激光测振仪 校准 – 机械运动 用激光测振仪直接测量（ČSN ISO 16063-41） 0,2 Hz 至 5 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,25 % 5 kHz 至 10 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,3 % 10 kHz 至 15 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,5 % 15 kHz 至 20 kHz 0,1 V/m·s⁻¹ 至 10 000 V/m·s⁻¹ CMC 0,7 % 0,2 Hz 至 5 kHz 0,01 V/m 至 10 000 V/m CMC 0,25 % 5 kHz 至 10 kHz 0,01 V/m 至 10 000 V/m CMC 0,3 % 10 kHz 至 15 kHz 0,01 V/m 至 10 000 V/m CMC 0,5 % 15 kHz 至 20 kHz 0,01 V/m 至 10 000 V/m CMC 0,7 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f4f646cbd5aa759252900fda","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"8","test_object":"Przesunięcie fazowe czułości / Czujniki drgań, geofony, wibrometry i tory pomiarowe drgań z wyjściem elektrycznym","test_object_en":"Sensitivity phase shift / Vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output","test_object_zh":"灵敏度相移 / 振动传感器、地震检波器、测振仪及带电输出的振动测量链","test_object_cs":"Fázový posuv citlivosti / Snímače vibrací, geofony, vibrometry a měřicí řetězce vibrací s elektrickým výstupem","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 1 Hz","range":"od 0 ° do 360 °","cmc":"1,5 °"},{"name":"1 Hz do 5 kHz","range":"od 0 ° do 360 °","cmc":"0,7 °"},{"name":"5 kHz do 10 kHz","range":"od 0 ° do 360 °","cmc":"1,0 °"},{"name":"10 kHz do 15 kHz","range":"od 0 ° do 360 °","cmc":"2,0 °"},{"name":"15 kHz do 20 kHz","range":"od 0 ° do 360 °","cmc":"3,0 °"}],"parameters_en":[{"name":"0,2 Hz to 1 Hz","range":"0 ° to 360 °","cmc":"1,5 °"},{"name":"1 Hz to 5 kHz","range":"0 ° to 360 °","cmc":"0,7 °"},{"name":"5 kHz to 10 kHz","range":"0 ° to 360 °","cmc":"1,0 °"},{"name":"10 kHz to 15 kHz","range":"0 ° to 360 °","cmc":"2,0 °"},{"name":"15 kHz to 20 kHz","range":"0 ° to 360 °","cmc":"3,0 °"}],"parameters_zh":[{"name":"0,2 Hz 至 1 Hz","range":"0 ° 至 360 °","cmc":"1,5 °"},{"name":"1 Hz 至 5 kHz","range":"0 ° 至 360 °","cmc":"0,7 °"},{"name":"5 kHz 至 10 kHz","range":"0 ° 至 360 °","cmc":"1,0 °"},{"name":"10 kHz 至 15 kHz","range":"0 ° 至 360 °","cmc":"2,0 °"},{"name":"15 kHz 至 20 kHz","range":"0 ° 至 360 °","cmc":"3,0 °"}],"parameters_cs":[{"name":"0,2 Hz až 1 Hz","range":"0 ° až 360 °","cmc":"1,5 °"},{"name":"1 Hz až 5 kHz","range":"0 ° až 360 °","cmc":"0,7 °"},{"name":"5 kHz až 10 kHz","range":"0 ° až 360 °","cmc":"1,0 °"},{"name":"10 kHz až 15 kHz","range":"0 ° až 360 °","cmc":"2,0 °"},{"name":"15 kHz až 20 kHz","range":"0 ° až 360 °","cmc":"3,0 °"}],"technique":"Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21)","technique_en":"Comparison with a reference sensor (ČSN ISO 16063-21)","technique_zh":"与参考传感器比较（ČSN ISO 16063-21）","technique_cs":"Porovnání s referenčním snímačem (ČSN ISO 16063-21)","techniques":["Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21)"],"techniques_en":["Comparison with a reference sensor (ČSN ISO 16063-21)"],"techniques_zh":["与参考传感器比较（ČSN ISO 16063-21）"],"techniques_cs":["Porovnání s referenčním snímačem (ČSN ISO 16063-21)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 1 Hz od 0 ° do 360 ° CMC 1,5 °\n1 Hz do 5 kHz od 0 ° do 360 ° CMC 0,7 °\n5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 °\n10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 °\n15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 °\nPorównanie z czujnikiem referencyjnym (ČSN ISO 16063-21)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przesunięcie fazowe czułości / Czujniki drgań, geofony, wibrometry i tory pomiarowe drgań z wyjściem elektrycznym Wzorcowanie – ruch mechaniczny Porównanie z czujnikiem referencyjnym (ČSN ISO 16063-21) 0,2 Hz do 1 Hz od 0 ° do 360 ° CMC 1,5 ° 1 Hz do 5 kHz od 0 ° do 360 ° CMC 0,7 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 ° 10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 ° 15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 ° Fázový posuv citlivosti / Snímače vibrací, geofony, vibrometry a měřicí řetězce vibrací s elektrickým výstupem Kalibrace – mechanický pohyb Porovnání s referenčním snímačem (ČSN ISO 16063-21) 0,2 Hz až 1 Hz 0 ° až 360 ° CMC 1,5 ° 1 Hz až 5 kHz 0 ° až 360 ° CMC 0,7 ° 5 kHz až 10 kHz 0 ° až 360 ° CMC 1,0 ° 10 kHz až 15 kHz 0 ° až 360 ° CMC 2,0 ° 15 kHz až 20 kHz 0 ° až 360 ° CMC 3,0 ° KP-01 Przesuniecie fazowe czulosci / Czujniki drgan, geofony, wibrometry i tory pomiarowe drgan z wyjsciem elektrycznym Wzorcowanie – ruch mechaniczny Porownanie z czujnikiem referencyjnym (CSN ISO 16063-21) 0,2 Hz do 1 Hz od 0 ° do 360 ° CMC 1,5 ° 1 Hz do 5 kHz od 0 ° do 360 ° CMC 0,7 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 ° 10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 ° 15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 ° Fazovy posuv citlivosti / Snimace vibraci, geofony, vibrometry a merici retezce vibraci s elektrickym vystupem Kalibrace – mechanicky pohyb Porovnani s referencnim snimacem (CSN ISO 16063-21) 0,2 Hz az 1 Hz 0 ° az 360 ° CMC 1,5 ° 1 Hz az 5 kHz 0 ° az 360 ° CMC 0,7 ° 5 kHz az 10 kHz 0 ° az 360 ° CMC 1,0 ° 10 kHz az 15 kHz 0 ° az 360 ° CMC 2,0 ° 15 kHz az 20 kHz 0 ° az 360 ° CMC 3,0 ° KP-01","search_en":"Sensitivity phase shift / Vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output Calibration – mechanical motion Comparison with a reference sensor (ČSN ISO 16063-21) 0,2 Hz to 1 Hz 0 ° to 360 ° CMC 1,5 ° 1 Hz to 5 kHz 0 ° to 360 ° CMC 0,7 ° 5 kHz to 10 kHz 0 ° to 360 ° CMC 1,0 ° 10 kHz to 15 kHz 0 ° to 360 ° CMC 2,0 ° 15 kHz to 20 kHz 0 ° to 360 ° CMC 3,0 ° KP-01","search_zh":"灵敏度相移 / 振动传感器、地震检波器、测振仪及带电输出的振动测量链 校准 – 机械运动 与参考传感器比较（ČSN ISO 16063-21） 0,2 Hz 至 1 Hz 0 ° 至 360 ° CMC 1,5 ° 1 Hz 至 5 kHz 0 ° 至 360 ° CMC 0,7 ° 5 kHz 至 10 kHz 0 ° 至 360 ° CMC 1,0 ° 10 kHz 至 15 kHz 0 ° 至 360 ° CMC 2,0 ° 15 kHz 至 20 kHz 0 ° 至 360 ° CMC 3,0 ° KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"77414d9a0f368de93b9a8f3d","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"9","test_object":"Przesunięcie fazowe czułości / Czujniki drgań, wzorcowe czujniki drgań, geofony, wibrometry i tory pomiarowe drgań z wyjściem elektrycznym","test_object_en":"Sensitivity phase shift / Vibration transducers, standard vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output","test_object_zh":"灵敏度相移 / 振动传感器、标准振动传感器、地震检波器、测振仪及带电输出的振动测量链","test_object_cs":"Fázový posuv citlivosti / Snímače vibrací, etalonové snímače vibrací, geofony, vibrometry a měřicí řetězce vibrací s elektrickým výstupem","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 0,4 Hz","range":"od 0 ° do 360 °","cmc":"0,7 °"},{"name":"0,4 Hz do 5 kHz","range":"od 0 ° do 360 °","cmc":"0,5 °"},{"name":"5 kHz do 10 kHz","range":"od 0 ° do 360 °","cmc":"1,0 °"},{"name":"10 kHz do 15 kHz","range":"od 0 ° do 360 °","cmc":"2,0 °"},{"name":"15 kHz do 20 kHz","range":"od 0 ° do 360 °","cmc":"3,0 °"}],"parameters_en":[{"name":"0,2 Hz to 0,4 Hz","range":"0 ° to 360 °","cmc":"0,7 °"},{"name":"0,4 Hz to 5 kHz","range":"0 ° to 360 °","cmc":"0,5 °"},{"name":"5 kHz to 10 kHz","range":"0 ° to 360 °","cmc":"1,0 °"},{"name":"10 kHz to 15 kHz","range":"0 ° to 360 °","cmc":"2,0 °"},{"name":"15 kHz to 20 kHz","range":"0 ° to 360 °","cmc":"3,0 °"}],"parameters_zh":[{"name":"0,2 Hz 至 0,4 Hz","range":"0 ° 至 360 °","cmc":"0,7 °"},{"name":"0,4 Hz 至 5 kHz","range":"0 ° 至 360 °","cmc":"0,5 °"},{"name":"5 kHz 至 10 kHz","range":"0 ° 至 360 °","cmc":"1,0 °"},{"name":"10 kHz 至 15 kHz","range":"0 ° 至 360 °","cmc":"2,0 °"},{"name":"15 kHz 至 20 kHz","range":"0 ° 至 360 °","cmc":"3,0 °"}],"parameters_cs":[{"name":"0,2 Hz až 0,4 Hz","range":"0 ° až 360 °","cmc":"0,7 °"},{"name":"0,4 Hz až 5 kHz","range":"0 ° až 360 °","cmc":"0,5 °"},{"name":"5 kHz až 10 kHz","range":"0 ° až 360 °","cmc":"1,0 °"},{"name":"10 kHz až 15 kHz","range":"0 ° až 360 °","cmc":"2,0 °"},{"name":"15 kHz až 20 kHz","range":"0 ° až 360 °","cmc":"3,0 °"}],"technique":"Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11)","technique_en":"Direct measurement with a laser vibrometer (ČSN ISO 16063-11)","technique_zh":"用激光测振仪直接测量（ČSN ISO 16063-11）","technique_cs":"Přímé měření laserovým vibrometrem (ČSN ISO 16063-11)","techniques":["Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11)"],"techniques_en":["Direct measurement with a laser vibrometer (ČSN ISO 16063-11)"],"techniques_zh":["用激光测振仪直接测量（ČSN ISO 16063-11）"],"techniques_cs":["Přímé měření laserovým vibrometrem (ČSN ISO 16063-11)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 0,4 Hz od 0 ° do 360 ° CMC 0,7 °\n0,4 Hz do 5 kHz od 0 ° do 360 ° CMC 0,5 °\n5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 °\n10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 °\n15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 °\nPomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przesunięcie fazowe czułości / Czujniki drgań, wzorcowe czujniki drgań, geofony, wibrometry i tory pomiarowe drgań z wyjściem elektrycznym Wzorcowanie – ruch mechaniczny Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-11) 0,2 Hz do 0,4 Hz od 0 ° do 360 ° CMC 0,7 ° 0,4 Hz do 5 kHz od 0 ° do 360 ° CMC 0,5 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 ° 10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 ° 15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 ° Fázový posuv citlivosti / Snímače vibrací, etalonové snímače vibrací, geofony, vibrometry a měřicí řetězce vibrací s elektrickým výstupem Kalibrace – mechanický pohyb Přímé měření laserovým vibrometrem (ČSN ISO 16063-11) 0,2 Hz až 0,4 Hz 0 ° až 360 ° CMC 0,7 ° 0,4 Hz až 5 kHz 0 ° až 360 ° CMC 0,5 ° 5 kHz až 10 kHz 0 ° až 360 ° CMC 1,0 ° 10 kHz až 15 kHz 0 ° až 360 ° CMC 2,0 ° 15 kHz až 20 kHz 0 ° až 360 ° CMC 3,0 ° KP-01 Przesuniecie fazowe czulosci / Czujniki drgan, wzorcowe czujniki drgan, geofony, wibrometry i tory pomiarowe drgan z wyjsciem elektrycznym Wzorcowanie – ruch mechaniczny Pomiar bezposredni wibrometrem laserowym (CSN ISO 16063-11) 0,2 Hz do 0,4 Hz od 0 ° do 360 ° CMC 0,7 ° 0,4 Hz do 5 kHz od 0 ° do 360 ° CMC 0,5 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 1,0 ° 10 kHz do 15 kHz od 0 ° do 360 ° CMC 2,0 ° 15 kHz do 20 kHz od 0 ° do 360 ° CMC 3,0 ° Fazovy posuv citlivosti / Snimace vibraci, etalonove snimace vibraci, geofony, vibrometry a merici retezce vibraci s elektrickym vystupem Kalibrace – mechanicky pohyb Prime mereni laserovym vibrometrem (CSN ISO 16063-11) 0,2 Hz az 0,4 Hz 0 ° az 360 ° CMC 0,7 ° 0,4 Hz az 5 kHz 0 ° az 360 ° CMC 0,5 ° 5 kHz az 10 kHz 0 ° az 360 ° CMC 1,0 ° 10 kHz az 15 kHz 0 ° az 360 ° CMC 2,0 ° 15 kHz az 20 kHz 0 ° az 360 ° CMC 3,0 ° KP-01","search_en":"Sensitivity phase shift / Vibration transducers, standard vibration transducers, geophones, vibrometers and vibration measurement chains with an electric output Calibration – mechanical motion Direct measurement with a laser vibrometer (ČSN ISO 16063-11) 0,2 Hz to 0,4 Hz 0 ° to 360 ° CMC 0,7 ° 0,4 Hz to 5 kHz 0 ° to 360 ° CMC 0,5 ° 5 kHz to 10 kHz 0 ° to 360 ° CMC 1,0 ° 10 kHz to 15 kHz 0 ° to 360 ° CMC 2,0 ° 15 kHz to 20 kHz 0 ° to 360 ° CMC 3,0 ° KP-01","search_zh":"灵敏度相移 / 振动传感器、标准振动传感器、地震检波器、测振仪及带电输出的振动测量链 校准 – 机械运动 用激光测振仪直接测量（ČSN ISO 16063-11） 0,2 Hz 至 0,4 Hz 0 ° 至 360 ° CMC 0,7 ° 0,4 Hz 至 5 kHz 0 ° 至 360 ° CMC 0,5 ° 5 kHz 至 10 kHz 0 ° 至 360 ° CMC 1,0 ° 10 kHz 至 15 kHz 0 ° 至 360 ° CMC 2,0 ° 15 kHz 至 20 kHz 0 ° 至 360 ° CMC 3,0 ° KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"95f9008e9564c4a199dc3c8d","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"10","test_object":"Przesunięcie fazowe czułości / Wibrometry laserowe z wyjściem elektrycznym","test_object_en":"Sensitivity phase shift / Laser vibrometers with an electric output","test_object_zh":"灵敏度相移 / 带电输出的激光测振仪","test_object_cs":"Fázový posuv citlivosti / Laserové vibrometry s elektrickým výstupem","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 5 kHz","range":"od 0 ° do 360 °","cmc":"0,5 °"},{"name":"5 kHz do 10 kHz","range":"od 0 ° do 360 °","cmc":"0,7 °"},{"name":"10 kHz do 20 kHz","range":"od 0 ° do 360 °","cmc":"1,5 °"}],"parameters_en":[{"name":"0,2 Hz to 5 kHz","range":"0 ° to 360 °","cmc":"0,5 °"},{"name":"5 kHz to 10 kHz","range":"0 ° to 360 °","cmc":"0,7 °"},{"name":"10 kHz to 20 kHz","range":"0 ° to 360 °","cmc":"1,5 °"}],"parameters_zh":[{"name":"0,2 Hz 至 5 kHz","range":"0 ° 至 360 °","cmc":"0,5 °"},{"name":"5 kHz 至 10 kHz","range":"0 ° 至 360 °","cmc":"0,7 °"},{"name":"10 kHz 至 20 kHz","range":"0 ° 至 360 °","cmc":"1,5 °"}],"parameters_cs":[{"name":"0,2 Hz až 5 kHz","range":"0 ° až 360 °","cmc":"0,5 °"},{"name":"5 kHz až 10 kHz","range":"0 ° až 360 °","cmc":"0,7 °"},{"name":"10 kHz až 20 kHz","range":"0 ° až 360 °","cmc":"1,5 °"}],"technique":"Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-41)","technique_en":"Direct measurement with a laser vibrometer (ČSN ISO 16063-41)","technique_zh":"用激光测振仪直接测量（ČSN ISO 16063-41）","technique_cs":"Přímé měření laserovým vibrometrem (ČSN ISO 16063-41)","techniques":["Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-41)"],"techniques_en":["Direct measurement with a laser vibrometer (ČSN ISO 16063-41)"],"techniques_zh":["用激光测振仪直接测量（ČSN ISO 16063-41）"],"techniques_cs":["Přímé měření laserovým vibrometrem (ČSN ISO 16063-41)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 5 kHz od 0 ° do 360 ° CMC 0,5 °\n5 kHz do 10 kHz od 0 ° do 360 ° CMC 0,7 °\n10 kHz do 20 kHz od 0 ° do 360 ° CMC 1,5 °\nPomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-41)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przesunięcie fazowe czułości / Wibrometry laserowe z wyjściem elektrycznym Wzorcowanie – ruch mechaniczny Pomiar bezpośredni wibrometrem laserowym (ČSN ISO 16063-41) 0,2 Hz do 5 kHz od 0 ° do 360 ° CMC 0,5 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 0,7 ° 10 kHz do 20 kHz od 0 ° do 360 ° CMC 1,5 ° Fázový posuv citlivosti / Laserové vibrometry s elektrickým výstupem Kalibrace – mechanický pohyb Přímé měření laserovým vibrometrem (ČSN ISO 16063-41) 0,2 Hz až 5 kHz 0 ° až 360 ° CMC 0,5 ° 5 kHz až 10 kHz 0 ° až 360 ° CMC 0,7 ° 10 kHz až 20 kHz 0 ° až 360 ° CMC 1,5 ° KP-01 Przesuniecie fazowe czulosci / Wibrometry laserowe z wyjsciem elektrycznym Wzorcowanie – ruch mechaniczny Pomiar bezposredni wibrometrem laserowym (CSN ISO 16063-41) 0,2 Hz do 5 kHz od 0 ° do 360 ° CMC 0,5 ° 5 kHz do 10 kHz od 0 ° do 360 ° CMC 0,7 ° 10 kHz do 20 kHz od 0 ° do 360 ° CMC 1,5 ° Fazovy posuv citlivosti / Laserove vibrometry s elektrickym vystupem Kalibrace – mechanicky pohyb Prime mereni laserovym vibrometrem (CSN ISO 16063-41) 0,2 Hz az 5 kHz 0 ° az 360 ° CMC 0,5 ° 5 kHz az 10 kHz 0 ° az 360 ° CMC 0,7 ° 10 kHz az 20 kHz 0 ° az 360 ° CMC 1,5 ° KP-01","search_en":"Sensitivity phase shift / Laser vibrometers with an electric output Calibration – mechanical motion Direct measurement with a laser vibrometer (ČSN ISO 16063-41) 0,2 Hz to 5 kHz 0 ° to 360 ° CMC 0,5 ° 5 kHz to 10 kHz 0 ° to 360 ° CMC 0,7 ° 10 kHz to 20 kHz 0 ° to 360 ° CMC 1,5 ° KP-01","search_zh":"灵敏度相移 / 带电输出的激光测振仪 校准 – 机械运动 用激光测振仪直接测量（ČSN ISO 16063-41） 0,2 Hz 至 5 kHz 0 ° 至 360 ° CMC 0,5 ° 5 kHz 至 10 kHz 0 ° 至 360 ° CMC 0,7 ° 10 kHz 至 20 kHz 0 ° 至 360 ° CMC 1,5 ° KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f49ce64a8c9e3bdf5b567367","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"11","test_object":"Częstotliwość prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, generatory drgań prostoliniowych, systemy do badań wibracyjnych","test_object_en":"Frequency of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems","test_object_zh":"简谐直线机械振动频率 / 测振仪、地震仪、直线振动发生器、振动测试系统","test_object_cs":"Frekvence přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, generátory přímočarých vibrací, vibrační testovací systémy","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"","range":"od 0,2 Hz do 50 kHz","cmc":"0,01 %"}],"parameters_en":[{"name":"","range":"0,2 Hz to 50 kHz","cmc":"0,01 %"}],"parameters_zh":[{"name":"","range":"0,2 Hz 至 50 kHz","cmc":"0,01 %"}],"parameters_cs":[{"name":"","range":"0,2 Hz až 50 kHz","cmc":"0,01 %"}],"technique":"Pomiar lub porównanie na wzorcowym urządzeniu wzorcującym lub za pomocą referencyjnego częstościomierza (ČSN ISO 16063-21, ČSN ISO 16063-44)","technique_en":"Measurement or comparison on a standard calibration device or with a reference frequency counter (ČSN ISO 16063-21, ČSN ISO 16063-44)","technique_zh":"在标准校准装置上或借助参考频率计测量或比较（ČSN ISO 16063-21、ČSN ISO 16063-44）","technique_cs":"Měření nebo porovnání na etalonovém kalibračním zařízení nebo s pomocí referenčního frekvenčního čítače (ČSN ISO 16063-21, ČSN ISO 16063-44)","techniques":["Pomiar lub porównanie na wzorcowym urządzeniu wzorcującym lub za pomocą referencyjnego częstościomierza (ČSN ISO 16063-21, ČSN ISO 16063-44)"],"techniques_en":["Measurement or comparison on a standard calibration device or with a reference frequency counter (ČSN ISO 16063-21, ČSN ISO 16063-44)"],"techniques_zh":["在标准校准装置上或借助参考频率计测量或比较（ČSN ISO 16063-21、ČSN ISO 16063-44）"],"techniques_cs":["Měření nebo porovnání na etalonovém kalibračním zařízení nebo s pomocí referenčního frekvenčního čítače (ČSN ISO 16063-21, ČSN ISO 16063-44)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nod 0,2 Hz do 50 kHz CMC 0,01 %\nPomiar lub porównanie na wzorcowym urządzeniu wzorcującym lub za pomocą referencyjnego częstościomierza (ČSN ISO 16063-21, ČSN ISO 16063-44)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, generatory drgań prostoliniowych, systemy do badań wibracyjnych Wzorcowanie – ruch mechaniczny Pomiar lub porównanie na wzorcowym urządzeniu wzorcującym lub za pomocą referencyjnego częstościomierza (ČSN ISO 16063-21, ČSN ISO 16063-44) od 0,2 Hz do 50 kHz CMC 0,01 % Frekvence přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, generátory přímočarých vibrací, vibrační testovací systémy Kalibrace – mechanický pohyb Měření nebo porovnání na etalonovém kalibračním zařízení nebo s pomocí referenčního frekvenčního čítače (ČSN ISO 16063-21, ČSN ISO 16063-44) 0,2 Hz až 50 kHz CMC 0,01 % KP-01 Czestotliwosc prostoliniowych drgan mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, generatory drgan prostoliniowych, systemy do badan wibracyjnych Wzorcowanie – ruch mechaniczny Pomiar lub porownanie na wzorcowym urzadzeniu wzorcujacym lub za pomoca referencyjnego czestosciomierza (CSN ISO 16063-21, CSN ISO 16063-44) od 0,2 Hz do 50 kHz CMC 0,01 % Frekvence primocarych mechanickych vibraci harmonickeho prubehu / Vibrometry, seismometry, generatory primocarych vibraci, vibracni testovaci systemy Kalibrace – mechanicky pohyb Mereni nebo porovnani na etalonovem kalibracnim zarizeni nebo s pomoci referencniho frekvencniho citace (CSN ISO 16063-21, CSN ISO 16063-44) 0,2 Hz az 50 kHz CMC 0,01 % KP-01","search_en":"Frequency of linear harmonic mechanical vibrations / Vibrometers, seismometers, linear vibration generators, vibration testing systems Calibration – mechanical motion Measurement or comparison on a standard calibration device or with a reference frequency counter (ČSN ISO 16063-21, ČSN ISO 16063-44) 0,2 Hz to 50 kHz CMC 0,01 % KP-01","search_zh":"简谐直线机械振动频率 / 测振仪、地震仪、直线振动发生器、振动测试系统 校准 – 机械运动 在标准校准装置上或借助参考频率计测量或比较（ČSN ISO 16063-21、ČSN ISO 16063-44） 0,2 Hz 至 50 kHz CMC 0,01 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d7365f0fd396cf703a061c6","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"12","test_object":"Częstotliwość prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, systemy wzorcowania czujników drgań, referencyjne generatory drgań prostoliniowych","test_object_en":"Frequency of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators","test_object_zh":"简谐直线机械振动频率 / 测振仪、地震仪、振动传感器校准系统、参考直线振动发生器","test_object_cs":"Frekvence přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, kalibrační systémy snímačů vibrací, referenční generátory přímočarých vibrací","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"","range":"od 0,2 Hz do 50 kHz","cmc":"0,01 %"}],"parameters_en":[{"name":"","range":"0,2 Hz to 50 kHz","cmc":"0,01 %"}],"parameters_zh":[{"name":"","range":"0,2 Hz 至 50 kHz","cmc":"0,01 %"}],"parameters_cs":[{"name":"","range":"0,2 Hz až 50 kHz","cmc":"0,01 %"}],"technique":"Pomiar lub porównanie na wzorcowym urządzeniu wzorcującym lub za pomocą wzorcowego częstościomierza (ČSN ISO 16063-11, ČSN ISO 16063-44)","technique_en":"Measurement or comparison on a standard calibration device or with a standard frequency counter (ČSN ISO 16063-11, ČSN ISO 16063-44)","technique_zh":"在标准校准装置上或借助标准频率计测量或比较（ČSN ISO 16063-11、ČSN ISO 16063-44）","technique_cs":"Měření nebo porovnání na etalonovém kalibračním zařízení nebo s pomocí etalonového frekvenčního čítače (ČSN ISO 16063-11, ČSN ISO 16063-44)","techniques":["Pomiar lub porównanie na wzorcowym urządzeniu wzorcującym lub za pomocą wzorcowego częstościomierza (ČSN ISO 16063-11, ČSN ISO 16063-44)"],"techniques_en":["Measurement or comparison on a standard calibration device or with a standard frequency counter (ČSN ISO 16063-11, ČSN ISO 16063-44)"],"techniques_zh":["在标准校准装置上或借助标准频率计测量或比较（ČSN ISO 16063-11、ČSN ISO 16063-44）"],"techniques_cs":["Měření nebo porovnání na etalonovém kalibračním zařízení nebo s pomocí etalonového frekvenčního čítače (ČSN ISO 16063-11, ČSN ISO 16063-44)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nod 0,2 Hz do 50 kHz CMC 0,01 %\nPomiar lub porównanie na wzorcowym urządzeniu wzorcującym lub za pomocą wzorcowego częstościomierza (ČSN ISO 16063-11, ČSN ISO 16063-44)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, systemy wzorcowania czujników drgań, referencyjne generatory drgań prostoliniowych Wzorcowanie – ruch mechaniczny Pomiar lub porównanie na wzorcowym urządzeniu wzorcującym lub za pomocą wzorcowego częstościomierza (ČSN ISO 16063-11, ČSN ISO 16063-44) od 0,2 Hz do 50 kHz CMC 0,01 % Frekvence přímočarých mechanických vibrací harmonického průběhu / Vibrometry, seismometry, kalibrační systémy snímačů vibrací, referenční generátory přímočarých vibrací Kalibrace – mechanický pohyb Měření nebo porovnání na etalonovém kalibračním zařízení nebo s pomocí etalonového frekvenčního čítače (ČSN ISO 16063-11, ČSN ISO 16063-44) 0,2 Hz až 50 kHz CMC 0,01 % KP-01 Czestotliwosc prostoliniowych drgan mechanicznych o przebiegu harmonicznym / Wibrometry, sejsmometry, systemy wzorcowania czujnikow drgan, referencyjne generatory drgan prostoliniowych Wzorcowanie – ruch mechaniczny Pomiar lub porownanie na wzorcowym urzadzeniu wzorcujacym lub za pomoca wzorcowego czestosciomierza (CSN ISO 16063-11, CSN ISO 16063-44) od 0,2 Hz do 50 kHz CMC 0,01 % Frekvence primocarych mechanickych vibraci harmonickeho prubehu / Vibrometry, seismometry, kalibracni systemy snimacu vibraci, referencni generatory primocarych vibraci Kalibrace – mechanicky pohyb Mereni nebo porovnani na etalonovem kalibracnim zarizeni nebo s pomoci etalonoveho frekvencniho citace (CSN ISO 16063-11, CSN ISO 16063-44) 0,2 Hz az 50 kHz CMC 0,01 % KP-01","search_en":"Frequency of linear harmonic mechanical vibrations / Vibrometers, seismometers, vibration transducer calibration systems, reference linear vibration generators Calibration – mechanical motion Measurement or comparison on a standard calibration device or with a standard frequency counter (ČSN ISO 16063-11, ČSN ISO 16063-44) 0,2 Hz to 50 kHz CMC 0,01 % KP-01","search_zh":"简谐直线机械振动频率 / 测振仪、地震仪、振动传感器校准系统、参考直线振动发生器 校准 – 机械运动 在标准校准装置上或借助标准频率计测量或比较（ČSN ISO 16063-11、ČSN ISO 16063-44） 0,2 Hz 至 50 kHz CMC 0,01 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fb5baa2fdc2d7edc722a220f","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"13","test_object":"Współczynnik przenoszenia / Wzmacniacze ładunku, wzmacniacze napięciowe, filtry częstotliwościowe, kontrolery systemów do badań wibracyjnych","test_object_en":"Transfer / Charge amplifiers, voltage amplifiers, frequency filters, vibration test system controllers","test_object_zh":"传递系数 / 电荷放大器、电压放大器、频率滤波器、振动试验系统控制器","test_object_cs":"Přenos / Nábojové zesilovače, napěťové zesilovače, kmitočtové filtry, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,1 Hz do 1 Hz","range":"od 0,001 mV/pC do 1000 mV/pC","cmc":"0,4 %"},{"name":"1 Hz do 20 kHz","range":"od 0,001 mV/pC do 1000 mV/pC","cmc":"0,3 %"},{"name":"20 kHz do 50 kHz","range":"od 0,001 mV/pC do 1000 mV/pC","cmc":"1,0 %"},{"name":"0,1 Hz do 1 Hz","range":"od 0,001 V/V do 1000 V/V","cmc":"0,4 %"},{"name":"1 Hz do 20 kHz","range":"od 0,001 V/V do 1000 V/V","cmc":"0,3 %"},{"name":"20 kHz do 50 kHz","range":"od 0,001 V/V do 1000 V/V","cmc":"1,0 %"}],"parameters_en":[{"name":"0,1 Hz to 1 Hz","range":"0,001 mV/pC to 1000 mV/pC","cmc":"0,4 %"},{"name":"1 Hz to 20 kHz","range":"0,001 mV/pC to 1000 mV/pC","cmc":"0,3 %"},{"name":"20 kHz to 50 kHz","range":"0,001 mV/pC to 1000 mV/pC","cmc":"1,0 %"},{"name":"0,1 Hz to 1 Hz","range":"0,001 V/V to 1000 V/V","cmc":"0,4 %"},{"name":"1 Hz to 20 kHz","range":"0,001 V/V to 1000 V/V","cmc":"0,3 %"},{"name":"20 kHz to 50 kHz","range":"0,001 V/V to 1000 V/V","cmc":"1,0 %"}],"parameters_zh":[{"name":"0,1 Hz 至 1 Hz","range":"0,001 mV/pC 至 1000 mV/pC","cmc":"0,4 %"},{"name":"1 Hz 至 20 kHz","range":"0,001 mV/pC 至 1000 mV/pC","cmc":"0,3 %"},{"name":"20 kHz 至 50 kHz","range":"0,001 mV/pC 至 1000 mV/pC","cmc":"1,0 %"},{"name":"0,1 Hz 至 1 Hz","range":"0,001 V/V 至 1000 V/V","cmc":"0,4 %"},{"name":"1 Hz 至 20 kHz","range":"0,001 V/V 至 1000 V/V","cmc":"0,3 %"},{"name":"20 kHz 至 50 kHz","range":"0,001 V/V 至 1000 V/V","cmc":"1,0 %"}],"parameters_cs":[{"name":"0,1 Hz až 1 Hz","range":"0,001 mV/pC až 1000 mV/pC","cmc":"0,4 %"},{"name":"1 Hz až 20 kHz","range":"0,001 mV/pC až 1000 mV/pC","cmc":"0,3 %"},{"name":"20 kHz až 50 kHz","range":"0,001 mV/pC až 1000 mV/pC","cmc":"1,0 %"},{"name":"0,1 Hz až 1 Hz","range":"0,001 V/V až 1000 V/V","cmc":"0,4 %"},{"name":"1 Hz až 20 kHz","range":"0,001 V/V až 1000 V/V","cmc":"0,3 %"},{"name":"20 kHz až 50 kHz","range":"0,001 V/V až 1000 V/V","cmc":"1,0 %"}],"technique":"Symulowanym sygnałem elektrycznym","technique_en":"By simulated electrical signal","technique_zh":"用模拟电信号","technique_cs":"Simulovaným elektrickým signálem","techniques":["Symulowanym sygnałem elektrycznym"],"techniques_en":["By simulated electrical signal"],"techniques_zh":["用模拟电信号"],"techniques_cs":["Simulovaným elektrickým signálem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,1 Hz do 1 Hz od 0,001 mV/pC do 1000 mV/pC CMC 0,4 %\n1 Hz do 20 kHz od 0,001 mV/pC do 1000 mV/pC CMC 0,3 %\n20 kHz do 50 kHz od 0,001 mV/pC do 1000 mV/pC CMC 1,0 %\n0,1 Hz do 1 Hz od 0,001 V/V do 1000 V/V CMC 0,4 %\n1 Hz do 20 kHz od 0,001 V/V do 1000 V/V CMC 0,3 %\n20 kHz do 50 kHz od 0,001 V/V do 1000 V/V CMC 1,0 %\nSymulowanym sygnałem elektrycznym","reference":"KP-02","norm_bases":["KP-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik przenoszenia / Wzmacniacze ładunku, wzmacniacze napięciowe, filtry częstotliwościowe, kontrolery systemów do badań wibracyjnych Wzorcowanie – ruch mechaniczny Symulowanym sygnałem elektrycznym 0,1 Hz do 1 Hz od 0,001 mV/pC do 1000 mV/pC CMC 0,4 % 1 Hz do 20 kHz od 0,001 mV/pC do 1000 mV/pC CMC 0,3 % 20 kHz do 50 kHz od 0,001 mV/pC do 1000 mV/pC CMC 1,0 % 0,1 Hz do 1 Hz od 0,001 V/V do 1000 V/V CMC 0,4 % 1 Hz do 20 kHz od 0,001 V/V do 1000 V/V CMC 0,3 % 20 kHz do 50 kHz od 0,001 V/V do 1000 V/V CMC 1,0 % Přenos / Nábojové zesilovače, napěťové zesilovače, kmitočtové filtry, kontroléry vibračních testovacích systémů Kalibrace – mechanický pohyb Simulovaným elektrickým signálem 0,1 Hz až 1 Hz 0,001 mV/pC až 1000 mV/pC CMC 0,4 % 1 Hz až 20 kHz 0,001 mV/pC až 1000 mV/pC CMC 0,3 % 20 kHz až 50 kHz 0,001 mV/pC až 1000 mV/pC CMC 1,0 % 0,1 Hz až 1 Hz 0,001 V/V až 1000 V/V CMC 0,4 % 1 Hz až 20 kHz 0,001 V/V až 1000 V/V CMC 0,3 % 20 kHz až 50 kHz 0,001 V/V až 1000 V/V CMC 1,0 % KP-02 Wspolczynnik przenoszenia / Wzmacniacze ladunku, wzmacniacze napieciowe, filtry czestotliwosciowe, kontrolery systemow do badan wibracyjnych Wzorcowanie – ruch mechaniczny Symulowanym sygnalem elektrycznym 0,1 Hz do 1 Hz od 0,001 mV/pC do 1000 mV/pC CMC 0,4 % 1 Hz do 20 kHz od 0,001 mV/pC do 1000 mV/pC CMC 0,3 % 20 kHz do 50 kHz od 0,001 mV/pC do 1000 mV/pC CMC 1,0 % 0,1 Hz do 1 Hz od 0,001 V/V do 1000 V/V CMC 0,4 % 1 Hz do 20 kHz od 0,001 V/V do 1000 V/V CMC 0,3 % 20 kHz do 50 kHz od 0,001 V/V do 1000 V/V CMC 1,0 % Prenos / Nabojove zesilovace, napetove zesilovace, kmitoctove filtry, kontrolery vibracnich testovacich systemu Kalibrace – mechanicky pohyb Simulovanym elektrickym signalem 0,1 Hz az 1 Hz 0,001 mV/pC az 1000 mV/pC CMC 0,4 % 1 Hz az 20 kHz 0,001 mV/pC az 1000 mV/pC CMC 0,3 % 20 kHz az 50 kHz 0,001 mV/pC az 1000 mV/pC CMC 1,0 % 0,1 Hz az 1 Hz 0,001 V/V az 1000 V/V CMC 0,4 % 1 Hz az 20 kHz 0,001 V/V az 1000 V/V CMC 0,3 % 20 kHz az 50 kHz 0,001 V/V az 1000 V/V CMC 1,0 % KP-02","search_en":"Transfer / Charge amplifiers, voltage amplifiers, frequency filters, vibration test system controllers Calibration – mechanical motion By simulated electrical signal 0,1 Hz to 1 Hz 0,001 mV/pC to 1000 mV/pC CMC 0,4 % 1 Hz to 20 kHz 0,001 mV/pC to 1000 mV/pC CMC 0,3 % 20 kHz to 50 kHz 0,001 mV/pC to 1000 mV/pC CMC 1,0 % 0,1 Hz to 1 Hz 0,001 V/V to 1000 V/V CMC 0,4 % 1 Hz to 20 kHz 0,001 V/V to 1000 V/V CMC 0,3 % 20 kHz to 50 kHz 0,001 V/V to 1000 V/V CMC 1,0 % KP-02","search_zh":"传递系数 / 电荷放大器、电压放大器、频率滤波器、振动试验系统控制器 校准 – 机械运动 用模拟电信号 0,1 Hz 至 1 Hz 0,001 mV/pC 至 1000 mV/pC CMC 0,4 % 1 Hz 至 20 kHz 0,001 mV/pC 至 1000 mV/pC CMC 0,3 % 20 kHz 至 50 kHz 0,001 mV/pC 至 1000 mV/pC CMC 1,0 % 0,1 Hz 至 1 Hz 0,001 V/V 至 1000 V/V CMC 0,4 % 1 Hz 至 20 kHz 0,001 V/V 至 1000 V/V CMC 0,3 % 20 kHz 至 50 kHz 0,001 V/V 至 1000 V/V CMC 1,0 % KP-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ac8db59f2cc461ee9f9ea7ca","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"14","test_object":"Przesunięcie fazowe współczynnika przenoszenia / Wzmacniacze ładunku, wzmacniacze napięciowe, filtry częstotliwościowe, kontrolery systemów do badań wibracyjnych","test_object_en":"Transfer phase shift / Charge amplifiers, voltage amplifiers, frequency filters, vibration test system controllers","test_object_zh":"传递相移 / 电荷放大器、电压放大器、频率滤波器、振动试验系统控制器","test_object_cs":"Fázový posuv přenosu / Nábojové zesilovače, napěťové zesilovače, kmitočtové filtry, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,1 Hz do 1 Hz","range":"od 0 ° do 360 °","cmc":"0,75 °"},{"name":"1 Hz do 20 kHz","range":"od 0 ° do 360 °","cmc":"0,5 °"}],"parameters_en":[{"name":"0,1 Hz to 1 Hz","range":"0 ° to 360 °","cmc":"0,75 °"},{"name":"1 Hz to 20 kHz","range":"0 ° to 360 °","cmc":"0,5 °"}],"parameters_zh":[{"name":"0,1 Hz 至 1 Hz","range":"0 ° 至 360 °","cmc":"0,75 °"},{"name":"1 Hz 至 20 kHz","range":"0 ° 至 360 °","cmc":"0,5 °"}],"parameters_cs":[{"name":"0,1 Hz až 1 Hz","range":"0 ° až 360 °","cmc":"0,75 °"},{"name":"1 Hz až 20 kHz","range":"0 ° až 360 °","cmc":"0,5 °"}],"technique":"Symulowanym sygnałem elektrycznym","technique_en":"By simulated electrical signal","technique_zh":"用模拟电信号","technique_cs":"Simulovaným elektrickým signálem","techniques":["Symulowanym sygnałem elektrycznym"],"techniques_en":["By simulated electrical signal"],"techniques_zh":["用模拟电信号"],"techniques_cs":["Simulovaným elektrickým signálem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,1 Hz do 1 Hz od 0 ° do 360 ° CMC 0,75 °\n1 Hz do 20 kHz od 0 ° do 360 ° CMC 0,5 °\nSymulowanym sygnałem elektrycznym","reference":"KP-02","norm_bases":["KP-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przesunięcie fazowe współczynnika przenoszenia / Wzmacniacze ładunku, wzmacniacze napięciowe, filtry częstotliwościowe, kontrolery systemów do badań wibracyjnych Wzorcowanie – ruch mechaniczny Symulowanym sygnałem elektrycznym 0,1 Hz do 1 Hz od 0 ° do 360 ° CMC 0,75 ° 1 Hz do 20 kHz od 0 ° do 360 ° CMC 0,5 ° Fázový posuv přenosu / Nábojové zesilovače, napěťové zesilovače, kmitočtové filtry, kontroléry vibračních testovacích systémů Kalibrace – mechanický pohyb Simulovaným elektrickým signálem 0,1 Hz až 1 Hz 0 ° až 360 ° CMC 0,75 ° 1 Hz až 20 kHz 0 ° až 360 ° CMC 0,5 ° KP-02 Przesuniecie fazowe wspolczynnika przenoszenia / Wzmacniacze ladunku, wzmacniacze napieciowe, filtry czestotliwosciowe, kontrolery systemow do badan wibracyjnych Wzorcowanie – ruch mechaniczny Symulowanym sygnalem elektrycznym 0,1 Hz do 1 Hz od 0 ° do 360 ° CMC 0,75 ° 1 Hz do 20 kHz od 0 ° do 360 ° CMC 0,5 ° Fazovy posuv prenosu / Nabojove zesilovace, napetove zesilovace, kmitoctove filtry, kontrolery vibracnich testovacich systemu Kalibrace – mechanicky pohyb Simulovanym elektrickym signalem 0,1 Hz az 1 Hz 0 ° az 360 ° CMC 0,75 ° 1 Hz az 20 kHz 0 ° az 360 ° CMC 0,5 ° KP-02","search_en":"Transfer phase shift / Charge amplifiers, voltage amplifiers, frequency filters, vibration test system controllers Calibration – mechanical motion By simulated electrical signal 0,1 Hz to 1 Hz 0 ° to 360 ° CMC 0,75 ° 1 Hz to 20 kHz 0 ° to 360 ° CMC 0,5 ° KP-02","search_zh":"传递相移 / 电荷放大器、电压放大器、频率滤波器、振动试验系统控制器 校准 – 机械运动 用模拟电信号 0,1 Hz 至 1 Hz 0 ° 至 360 ° CMC 0,75 ° 1 Hz 至 20 kHz 0 ° 至 360 ° CMC 0,5 ° KP-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5ee081d7bd560974f89772a2","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"15","test_object":"Przyspieszenie drgań o przebiegu harmonicznym / Wibrometry bez czujnika, tory pomiarowe bez czujnika z wyjściem na wyświetlacz lub skalę, kontrolery systemów do badań wibracyjnych","test_object_en":"Acceleration of harmonic vibrations / Vibrometers without a transducer, measuring chains without a transducer with an output to a display or a scale, vibration test system controllers","test_object_zh":"简谐振动加速度 / 无传感器测振仪、无传感器且输出至显示器或刻度盘的测量链、振动试验系统控制器","test_object_cs":"Zrychlení vibrací harmonického průběhu / Vibrometry bez snímače, měřicí řetězce bez snímače s výstupem na displej nebo stupnici, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,1 Hz do 1 Hz","range":"od 0,01 m·s⁻² do 10 000 m·s⁻²","cmc":"0,4 %"},{"name":"1 Hz do 20 kHz","range":"od 0,01 m·s⁻² do 10 000 m·s⁻²","cmc":"0,3 %"}],"parameters_en":[{"name":"0,1 Hz to 1 Hz","range":"0,01 m·s⁻² to 10 000 m·s⁻²","cmc":"0,4 %"},{"name":"1 Hz to 20 kHz","range":"0,01 m·s⁻² to 10 000 m·s⁻²","cmc":"0,3 %"}],"parameters_zh":[{"name":"0,1 Hz 至 1 Hz","range":"0,01 m·s⁻² 至 10 000 m·s⁻²","cmc":"0,4 %"},{"name":"1 Hz 至 20 kHz","range":"0,01 m·s⁻² 至 10 000 m·s⁻²","cmc":"0,3 %"}],"parameters_cs":[{"name":"0,1 Hz až 1 Hz","range":"0,01 m·s⁻² až 10 000 m·s⁻²","cmc":"0,4 %"},{"name":"1 Hz až 20 kHz","range":"0,01 m·s⁻² až 10 000 m·s⁻²","cmc":"0,3 %"}],"technique":"Symulowanym sygnałem elektrycznym","technique_en":"By simulated electrical signal","technique_zh":"用模拟电信号","technique_cs":"Simulovaným elektrickým signálem","techniques":["Symulowanym sygnałem elektrycznym"],"techniques_en":["By simulated electrical signal"],"techniques_zh":["用模拟电信号"],"techniques_cs":["Simulovaným elektrickým signálem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,1 Hz do 1 Hz od 0,01 m·s⁻² do 10 000 m·s⁻² CMC 0,4 %\n1 Hz do 20 kHz od 0,01 m·s⁻² do 10 000 m·s⁻² CMC 0,3 %\nSymulowanym sygnałem elektrycznym","reference":"KP-02","norm_bases":["KP-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":"Wielkością wzorcowaną mogą być także prędkość i wychylenie, pod warunkiem wzorcowania sygnałem drgań o przebiegu harmonicznym o znanej częstotliwości. Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻².","note_en":"The calibrated quantities may include also the velocity and deviation, if the calibration is carried out using a harmonic vibration signal of a known frequency. Acceleration can be specified also in g, sensor sensitivity in pC/g, resp. mV/g units, where 1 g = 9.807 m·s⁻².","note_zh":"被校量也可以是速度和位移，前提是使用已知频率的简谐振动信号进行校准。加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²。","note_cs":"Kalibrovanou veličinou mohou být i rychlost a výchylka, za předpokladu kalibrace pomocí vibračního signálu harmonického průběhu na známém kmitočtu. Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻².","search_text":"Przyspieszenie drgań o przebiegu harmonicznym / Wibrometry bez czujnika, tory pomiarowe bez czujnika z wyjściem na wyświetlacz lub skalę, kontrolery systemów do badań wibracyjnych Wzorcowanie – ruch mechaniczny Symulowanym sygnałem elektrycznym 0,1 Hz do 1 Hz od 0,01 m·s⁻² do 10 000 m·s⁻² CMC 0,4 % 1 Hz do 20 kHz od 0,01 m·s⁻² do 10 000 m·s⁻² CMC 0,3 % Zrychlení vibrací harmonického průběhu / Vibrometry bez snímače, měřicí řetězce bez snímače s výstupem na displej nebo stupnici, kontroléry vibračních testovacích systémů Kalibrace – mechanický pohyb Simulovaným elektrickým signálem 0,1 Hz až 1 Hz 0,01 m·s⁻² až 10 000 m·s⁻² CMC 0,4 % 1 Hz až 20 kHz 0,01 m·s⁻² až 10 000 m·s⁻² CMC 0,3 % KP-02 Przyspieszenie drgan o przebiegu harmonicznym / Wibrometry bez czujnika, tory pomiarowe bez czujnika z wyjsciem na wyswietlacz lub skale, kontrolery systemow do badan wibracyjnych Wzorcowanie – ruch mechaniczny Symulowanym sygnalem elektrycznym 0,1 Hz do 1 Hz od 0,01 m·s⁻² do 10 000 m·s⁻² CMC 0,4 % 1 Hz do 20 kHz od 0,01 m·s⁻² do 10 000 m·s⁻² CMC 0,3 % Zrychleni vibraci harmonickeho prubehu / Vibrometry bez snimace, merici retezce bez snimace s vystupem na displej nebo stupnici, kontrolery vibracnich testovacich systemu Kalibrace – mechanicky pohyb Simulovanym elektrickym signalem 0,1 Hz az 1 Hz 0,01 m·s⁻² az 10 000 m·s⁻² CMC 0,4 % 1 Hz az 20 kHz 0,01 m·s⁻² az 10 000 m·s⁻² CMC 0,3 % KP-02","search_en":"Acceleration of harmonic vibrations / Vibrometers without a transducer, measuring chains without a transducer with an output to a display or a scale, vibration test system controllers Calibration – mechanical motion By simulated electrical signal 0,1 Hz to 1 Hz 0,01 m·s⁻² to 10 000 m·s⁻² CMC 0,4 % 1 Hz to 20 kHz 0,01 m·s⁻² to 10 000 m·s⁻² CMC 0,3 % KP-02","search_zh":"简谐振动加速度 / 无传感器测振仪、无传感器且输出至显示器或刻度盘的测量链、振动试验系统控制器 校准 – 机械运动 用模拟电信号 0,1 Hz 至 1 Hz 0,01 m·s⁻² 至 10 000 m·s⁻² CMC 0,4 % 1 Hz 至 20 kHz 0,01 m·s⁻² 至 10 000 m·s⁻² CMC 0,3 % KP-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6b13c75c063b50def40d77b","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"16","test_object":"Wartość maksymalna przyspieszenia udarów mechanicznych o przebiegu półsinusoidalnym / mierniki udarów","test_object_en":"Maximum value of half-sine wave mechanical shock acceleration / shock meters","test_object_zh":"半正弦机械冲击加速度最大值 / 冲击测量仪","test_object_cs":"Maximální hodnota zrychlení mechanických rázů půlsinusového průběhu / měřiče rázů","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"","range":"od 50 m·s⁻² do 200 m·s⁻²","cmc":"2,0 %"},{"name":"","range":"od 200 m·s⁻² do 2 km·s⁻²","cmc":"1,5 %"},{"name":"","range":"od 2 km·s⁻² do 40 km·s⁻²","cmc":"1,8 %"},{"name":"","range":"od 40 km·s⁻² do 100 km·s⁻²","cmc":"3,0 %"}],"parameters_en":[{"name":"","range":"50 m·s⁻² to 200 m·s⁻²","cmc":"2,0 %"},{"name":"","range":"200 m·s⁻² to 2 km·s⁻²","cmc":"1,5 %"},{"name":"","range":"2 km·s⁻² to 40 km·s⁻²","cmc":"1,8 %"},{"name":"","range":"40 km·s⁻² to 100 km·s⁻²","cmc":"3,0 %"}],"parameters_zh":[{"name":"","range":"50 m·s⁻² 至 200 m·s⁻²","cmc":"2,0 %"},{"name":"","range":"200 m·s⁻² 至 2 km·s⁻²","cmc":"1,5 %"},{"name":"","range":"2 km·s⁻² 至 40 km·s⁻²","cmc":"1,8 %"},{"name":"","range":"40 km·s⁻² 至 100 km·s⁻²","cmc":"3,0 %"}],"parameters_cs":[{"name":"","range":"50 m·s⁻² až 200 m·s⁻²","cmc":"2,0 %"},{"name":"","range":"200 m·s⁻² až 2 km·s⁻²","cmc":"1,5 %"},{"name":"","range":"2 km·s⁻² až 40 km·s⁻²","cmc":"1,8 %"},{"name":"","range":"40 km·s⁻² až 100 km·s⁻²","cmc":"3,0 %"}],"technique":"Pomiar bezpośredni lub porównanie z czujnikiem wzorcowym (ČSN ISO 16063-22)","technique_en":"Direct measurement or comparison with a reference sensor (ČSN ISO 16063-22)","technique_zh":"直接测量或与标准传感器比较（ČSN ISO 16063-22）","technique_cs":"Přímé měření nebo porovnání s etalonovým snímačem (ČSN ISO 16063-22)","techniques":["Pomiar bezpośredni lub porównanie z czujnikiem wzorcowym (ČSN ISO 16063-22)"],"techniques_en":["Direct measurement or comparison with a reference sensor (ČSN ISO 16063-22)"],"techniques_zh":["直接测量或与标准传感器比较（ČSN ISO 16063-22）"],"techniques_cs":["Přímé měření nebo porovnání s etalonovým snímačem (ČSN ISO 16063-22)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\nod 50 m·s⁻² do 200 m·s⁻² CMC 2,0 %\nod 200 m·s⁻² do 2 km·s⁻² CMC 1,5 %\nod 2 km·s⁻² do 40 km·s⁻² CMC 1,8 %\nod 40 km·s⁻² do 100 km·s⁻² CMC 3,0 %\nPomiar bezpośredni lub porównanie z czujnikiem wzorcowym (ČSN ISO 16063-22)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wartość maksymalna przyspieszenia udarów mechanicznych o przebiegu półsinusoidalnym / mierniki udarów Wzorcowanie – ruch mechaniczny Pomiar bezpośredni lub porównanie z czujnikiem wzorcowym (ČSN ISO 16063-22) od 50 m·s⁻² do 200 m·s⁻² CMC 2,0 % od 200 m·s⁻² do 2 km·s⁻² CMC 1,5 % od 2 km·s⁻² do 40 km·s⁻² CMC 1,8 % od 40 km·s⁻² do 100 km·s⁻² CMC 3,0 % Maximální hodnota zrychlení mechanických rázů půlsinusového průběhu / měřiče rázů Kalibrace – mechanický pohyb Přímé měření nebo porovnání s etalonovým snímačem (ČSN ISO 16063-22) 50 m·s⁻² až 200 m·s⁻² CMC 2,0 % 200 m·s⁻² až 2 km·s⁻² CMC 1,5 % 2 km·s⁻² až 40 km·s⁻² CMC 1,8 % 40 km·s⁻² až 100 km·s⁻² CMC 3,0 % KP-01 Wartosc maksymalna przyspieszenia udarow mechanicznych o przebiegu polsinusoidalnym / mierniki udarow Wzorcowanie – ruch mechaniczny Pomiar bezposredni lub porownanie z czujnikiem wzorcowym (CSN ISO 16063-22) od 50 m·s⁻² do 200 m·s⁻² CMC 2,0 % od 200 m·s⁻² do 2 km·s⁻² CMC 1,5 % od 2 km·s⁻² do 40 km·s⁻² CMC 1,8 % od 40 km·s⁻² do 100 km·s⁻² CMC 3,0 % Maximalni hodnota zrychleni mechanickych razu pulsinusoveho prubehu / merice razu Kalibrace – mechanicky pohyb Prime mereni nebo porovnani s etalonovym snimacem (CSN ISO 16063-22) 50 m·s⁻² az 200 m·s⁻² CMC 2,0 % 200 m·s⁻² az 2 km·s⁻² CMC 1,5 % 2 km·s⁻² az 40 km·s⁻² CMC 1,8 % 40 km·s⁻² az 100 km·s⁻² CMC 3,0 % KP-01","search_en":"Maximum value of half-sine wave mechanical shock acceleration / shock meters Calibration – mechanical motion Direct measurement or comparison with a reference sensor (ČSN ISO 16063-22) 50 m·s⁻² to 200 m·s⁻² CMC 2,0 % 200 m·s⁻² to 2 km·s⁻² CMC 1,5 % 2 km·s⁻² to 40 km·s⁻² CMC 1,8 % 40 km·s⁻² to 100 km·s⁻² CMC 3,0 % KP-01","search_zh":"半正弦机械冲击加速度最大值 / 冲击测量仪 校准 – 机械运动 直接测量或与标准传感器比较（ČSN ISO 16063-22） 50 m·s⁻² 至 200 m·s⁻² CMC 2,0 % 200 m·s⁻² 至 2 km·s⁻² CMC 1,5 % 2 km·s⁻² 至 40 km·s⁻² CMC 1,8 % 40 km·s⁻² 至 100 km·s⁻² CMC 3,0 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"add669f16b5e7d9069e918b6","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"17","test_object":"Czułość czujników przyspieszenia udarów mechanicznych o przebiegu półsinusoidalnym / czujniki udarów, czujniki drgań","test_object_en":"Sensitivity of half-sine wave mechanical shock acceleration sensors / shock sensors, vibration sensors","test_object_zh":"半正弦机械冲击加速度传感器灵敏度 / 冲击传感器、振动传感器","test_object_cs":"Citlivost snímačů zrychlení mechanických rázů půlsinusového průběhu / snímače rázů, snímače vibrací","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"50 m·s⁻² do 200 m·s⁻²","range":"od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻²","cmc":"2,0 %"},{"name":"200 m·s⁻² do 2 km·s⁻²","range":"od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻²","cmc":"1,5 %"},{"name":"2 do 40 km·s⁻²","range":"od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻²","cmc":"1,8 %"},{"name":"40 do 100 km·s⁻²","range":"od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻²","cmc":"3,0 %"},{"name":"50 m·s⁻² do 200 m·s⁻²","range":"od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻²","cmc":"2,0 %"},{"name":"200 m·s⁻² do 2 km·s⁻²","range":"od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻²","cmc":"1,5 %"},{"name":"2 do 40 km·s⁻²","range":"od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻²","cmc":"1,8 %"},{"name":"40 do 100 km·s⁻²","range":"od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻²","cmc":"3,0 %"}],"parameters_en":[{"name":"50 m·s⁻² to 200 m·s⁻²","range":"0,0001 mV/m·s⁻² to 100 mV/m·s⁻²","cmc":"2,0 %"},{"name":"200 m·s⁻² to 2 km·s⁻²","range":"0,0001 mV/m·s⁻² to 100 mV/m·s⁻²","cmc":"1,5 %"},{"name":"2 to 40 km·s⁻²","range":"0,0001 mV/m·s⁻² to 100 mV/m·s⁻²","cmc":"1,8 %"},{"name":"40 to 100 km·s⁻²","range":"0,0001 mV/m·s⁻² to 100 mV/m·s⁻²","cmc":"3,0 %"},{"name":"50 m·s⁻² to 200 m·s⁻²","range":"0,0001 pC/m·s⁻² to 100 pC/m·s⁻²","cmc":"2,0 %"},{"name":"200 m·s⁻² to 2 km·s⁻²","range":"0,0001 pC/m·s⁻² to 100 pC/m·s⁻²","cmc":"1,5 %"},{"name":"2 to 40 km·s⁻²","range":"0,0001 pC/m·s⁻² to 100 pC/m·s⁻²","cmc":"1,8 %"},{"name":"40 to 100 km·s⁻²","range":"0,0001 pC/m·s⁻² to 100 pC/m·s⁻²","cmc":"3,0 %"}],"parameters_zh":[{"name":"50 m·s⁻² 至 200 m·s⁻²","range":"0,0001 mV/m·s⁻² 至 100 mV/m·s⁻²","cmc":"2,0 %"},{"name":"200 m·s⁻² 至 2 km·s⁻²","range":"0,0001 mV/m·s⁻² 至 100 mV/m·s⁻²","cmc":"1,5 %"},{"name":"2 至 40 km·s⁻²","range":"0,0001 mV/m·s⁻² 至 100 mV/m·s⁻²","cmc":"1,8 %"},{"name":"40 至 100 km·s⁻²","range":"0,0001 mV/m·s⁻² 至 100 mV/m·s⁻²","cmc":"3,0 %"},{"name":"50 m·s⁻² 至 200 m·s⁻²","range":"0,0001 pC/m·s⁻² 至 100 pC/m·s⁻²","cmc":"2,0 %"},{"name":"200 m·s⁻² 至 2 km·s⁻²","range":"0,0001 pC/m·s⁻² 至 100 pC/m·s⁻²","cmc":"1,5 %"},{"name":"2 至 40 km·s⁻²","range":"0,0001 pC/m·s⁻² 至 100 pC/m·s⁻²","cmc":"1,8 %"},{"name":"40 至 100 km·s⁻²","range":"0,0001 pC/m·s⁻² 至 100 pC/m·s⁻²","cmc":"3,0 %"}],"parameters_cs":[{"name":"50 m·s⁻² až 200 m·s⁻²","range":"0,0001 mV/m·s⁻² až 100 mV/m·s⁻²","cmc":"2,0 %"},{"name":"200 m·s⁻² až 2 km·s⁻²","range":"0,0001 mV/m·s⁻² až 100 mV/m·s⁻²","cmc":"1,5 %"},{"name":"2 až 40 km·s⁻²","range":"0,0001 mV/m·s⁻² až 100 mV/m·s⁻²","cmc":"1,8 %"},{"name":"40 až 100 km·s⁻²","range":"0,0001 mV/m·s⁻² až 100 mV/m·s⁻²","cmc":"3,0 %"},{"name":"50 m·s⁻² až 200 m·s⁻²","range":"0,0001 pC/m·s⁻² až 100 pC/m·s⁻²","cmc":"2,0 %"},{"name":"200 m·s⁻² až 2 km·s⁻²","range":"0,0001 pC/m·s⁻² až 100 pC/m·s⁻²","cmc":"1,5 %"},{"name":"2 až 40 km·s⁻²","range":"0,0001 pC/m·s⁻² až 100 pC/m·s⁻²","cmc":"1,8 %"},{"name":"40 až 100 km·s⁻²","range":"0,0001 pC/m·s⁻² až 100 pC/m·s⁻²","cmc":"3,0 %"}],"technique":"Porównanie z czujnikiem wzorcowym (ČSN ISO 16063-22)","technique_en":"Comparison with a reference sensor (ČSN ISO 16063-22)","technique_zh":"与标准传感器比较（ČSN ISO 16063-22）","technique_cs":"Porovnání s etalonovým snímačem (ČSN ISO 16063-22)","techniques":["Porównanie z czujnikiem wzorcowym (ČSN ISO 16063-22)"],"techniques_en":["Comparison with a reference sensor (ČSN ISO 16063-22)"],"techniques_zh":["与标准传感器比较（ČSN ISO 16063-22）"],"techniques_cs":["Porovnání s etalonovým snímačem (ČSN ISO 16063-22)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n50 m·s⁻² do 200 m·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 2,0 %\n200 m·s⁻² do 2 km·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 1,5 %\n2 do 40 km·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 1,8 %\n40 do 100 km·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 3,0 %\n50 m·s⁻² do 200 m·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 2,0 %\n200 m·s⁻² do 2 km·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 1,5 %\n2 do 40 km·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 1,8 %\n40 do 100 km·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 3,0 %\nPorównanie z czujnikiem wzorcowym (ČSN ISO 16063-22)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czułość czujników przyspieszenia udarów mechanicznych o przebiegu półsinusoidalnym / czujniki udarów, czujniki drgań Wzorcowanie – ruch mechaniczny Porównanie z czujnikiem wzorcowym (ČSN ISO 16063-22) 50 m·s⁻² do 200 m·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 2,0 % 200 m·s⁻² do 2 km·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 1,5 % 2 do 40 km·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 1,8 % 40 do 100 km·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 3,0 % 50 m·s⁻² do 200 m·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 2,0 % 200 m·s⁻² do 2 km·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 1,5 % 2 do 40 km·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 1,8 % 40 do 100 km·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 3,0 % Citlivost snímačů zrychlení mechanických rázů půlsinusového průběhu / snímače rázů, snímače vibrací Kalibrace – mechanický pohyb Porovnání s etalonovým snímačem (ČSN ISO 16063-22) 50 m·s⁻² až 200 m·s⁻² 0,0001 mV/m·s⁻² až 100 mV/m·s⁻² CMC 2,0 % 200 m·s⁻² až 2 km·s⁻² 0,0001 mV/m·s⁻² až 100 mV/m·s⁻² CMC 1,5 % 2 až 40 km·s⁻² 0,0001 mV/m·s⁻² až 100 mV/m·s⁻² CMC 1,8 % 40 až 100 km·s⁻² 0,0001 mV/m·s⁻² až 100 mV/m·s⁻² CMC 3,0 % 50 m·s⁻² až 200 m·s⁻² 0,0001 pC/m·s⁻² až 100 pC/m·s⁻² CMC 2,0 % 200 m·s⁻² až 2 km·s⁻² 0,0001 pC/m·s⁻² až 100 pC/m·s⁻² CMC 1,5 % 2 až 40 km·s⁻² 0,0001 pC/m·s⁻² až 100 pC/m·s⁻² CMC 1,8 % 40 až 100 km·s⁻² 0,0001 pC/m·s⁻² až 100 pC/m·s⁻² CMC 3,0 % KP-01 Czulosc czujnikow przyspieszenia udarow mechanicznych o przebiegu polsinusoidalnym / czujniki udarow, czujniki drgan Wzorcowanie – ruch mechaniczny Porownanie z czujnikiem wzorcowym (CSN ISO 16063-22) 50 m·s⁻² do 200 m·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 2,0 % 200 m·s⁻² do 2 km·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 1,5 % 2 do 40 km·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 1,8 % 40 do 100 km·s⁻² od 0,0001 mV/m·s⁻² do 100 mV/m·s⁻² CMC 3,0 % 50 m·s⁻² do 200 m·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 2,0 % 200 m·s⁻² do 2 km·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 1,5 % 2 do 40 km·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 1,8 % 40 do 100 km·s⁻² od 0,0001 pC/m·s⁻² do 100 pC/m·s⁻² CMC 3,0 % Citlivost snimacu zrychleni mechanickych razu pulsinusoveho prubehu / snimace razu, snimace vibraci Kalibrace – mechanicky pohyb Porovnani s etalonovym snimacem (CSN ISO 16063-22) 50 m·s⁻² az 200 m·s⁻² 0,0001 mV/m·s⁻² az 100 mV/m·s⁻² CMC 2,0 % 200 m·s⁻² az 2 km·s⁻² 0,0001 mV/m·s⁻² az 100 mV/m·s⁻² CMC 1,5 % 2 az 40 km·s⁻² 0,0001 mV/m·s⁻² az 100 mV/m·s⁻² CMC 1,8 % 40 az 100 km·s⁻² 0,0001 mV/m·s⁻² az 100 mV/m·s⁻² CMC 3,0 % 50 m·s⁻² az 200 m·s⁻² 0,0001 pC/m·s⁻² az 100 pC/m·s⁻² CMC 2,0 % 200 m·s⁻² az 2 km·s⁻² 0,0001 pC/m·s⁻² az 100 pC/m·s⁻² CMC 1,5 % 2 az 40 km·s⁻² 0,0001 pC/m·s⁻² az 100 pC/m·s⁻² CMC 1,8 % 40 az 100 km·s⁻² 0,0001 pC/m·s⁻² az 100 pC/m·s⁻² CMC 3,0 % KP-01","search_en":"Sensitivity of half-sine wave mechanical shock acceleration sensors / shock sensors, vibration sensors Calibration – mechanical motion Comparison with a reference sensor (ČSN ISO 16063-22) 50 m·s⁻² to 200 m·s⁻² 0,0001 mV/m·s⁻² to 100 mV/m·s⁻² CMC 2,0 % 200 m·s⁻² to 2 km·s⁻² 0,0001 mV/m·s⁻² to 100 mV/m·s⁻² CMC 1,5 % 2 to 40 km·s⁻² 0,0001 mV/m·s⁻² to 100 mV/m·s⁻² CMC 1,8 % 40 to 100 km·s⁻² 0,0001 mV/m·s⁻² to 100 mV/m·s⁻² CMC 3,0 % 50 m·s⁻² to 200 m·s⁻² 0,0001 pC/m·s⁻² to 100 pC/m·s⁻² CMC 2,0 % 200 m·s⁻² to 2 km·s⁻² 0,0001 pC/m·s⁻² to 100 pC/m·s⁻² CMC 1,5 % 2 to 40 km·s⁻² 0,0001 pC/m·s⁻² to 100 pC/m·s⁻² CMC 1,8 % 40 to 100 km·s⁻² 0,0001 pC/m·s⁻² to 100 pC/m·s⁻² CMC 3,0 % KP-01","search_zh":"半正弦机械冲击加速度传感器灵敏度 / 冲击传感器、振动传感器 校准 – 机械运动 与标准传感器比较（ČSN ISO 16063-22） 50 m·s⁻² 至 200 m·s⁻² 0,0001 mV/m·s⁻² 至 100 mV/m·s⁻² CMC 2,0 % 200 m·s⁻² 至 2 km·s⁻² 0,0001 mV/m·s⁻² 至 100 mV/m·s⁻² CMC 1,5 % 2 至 40 km·s⁻² 0,0001 mV/m·s⁻² 至 100 mV/m·s⁻² CMC 1,8 % 40 至 100 km·s⁻² 0,0001 mV/m·s⁻² 至 100 mV/m·s⁻² CMC 3,0 % 50 m·s⁻² 至 200 m·s⁻² 0,0001 pC/m·s⁻² 至 100 pC/m·s⁻² CMC 2,0 % 200 m·s⁻² 至 2 km·s⁻² 0,0001 pC/m·s⁻² 至 100 pC/m·s⁻² CMC 1,5 % 2 至 40 km·s⁻² 0,0001 pC/m·s⁻² 至 100 pC/m·s⁻² CMC 1,8 % 40 至 100 km·s⁻² 0,0001 pC/m·s⁻² 至 100 pC/m·s⁻² CMC 3,0 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bad17ab89b023f15452dcb55","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"18","test_object":"Czułość czujników udarów mechanicznych o przebiegu półsinusoidalnym / młotki udarowe","test_object_en":"Sensitivity of half-sine wave mechanical shock sensors / shock hammers","test_object_zh":"半正弦机械冲击传感器灵敏度 / 冲击力锤","test_object_cs":"Citlivost snímačů mechanických rázů půlsinusového průběhu / rázová kladívka","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"","range":"od 0,1 mV/N do 100 mV/N","cmc":"3,0 %"},{"name":"","range":"od 0,1 pC/N do 100 pC/N","cmc":"3,0 %"}],"parameters_en":[{"name":"","range":"0,1 mV/N to 100 mV/N","cmc":"3,0 %"},{"name":"","range":"0,1 pC/N to 100 pC/N","cmc":"3,0 %"}],"parameters_zh":[{"name":"","range":"0,1 mV/N 至 100 mV/N","cmc":"3,0 %"},{"name":"","range":"0,1 pC/N 至 100 pC/N","cmc":"3,0 %"}],"parameters_cs":[{"name":"","range":"0,1 mV/N až 100 mV/N","cmc":"3,0 %"},{"name":"","range":"0,1 pC/N až 100 pC/N","cmc":"3,0 %"}],"technique":"Porównanie z czujnikiem wzorcowym z wykorzystaniem znanej masy reakcyjnej (ČSN ISO 16063-22)","technique_en":"Comparison with a reference sensor using a known reaction mass (ČSN ISO 16063-22)","technique_zh":"利用已知反作用质量与标准传感器比较（ČSN ISO 16063-22）","technique_cs":"Porovnání s etalonovým snímačem s využitím známé reakční hmoty (ČSN ISO 16063-22)","techniques":["Porównanie z czujnikiem wzorcowym z wykorzystaniem znanej masy reakcyjnej (ČSN ISO 16063-22)"],"techniques_en":["Comparison with a reference sensor using a known reaction mass (ČSN ISO 16063-22)"],"techniques_zh":["利用已知反作用质量与标准传感器比较（ČSN ISO 16063-22）"],"techniques_cs":["Porovnání s etalonovým snímačem s využitím známé reakční hmoty (ČSN ISO 16063-22)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\nod 0,1 mV/N do 100 mV/N CMC 3,0 %\nod 0,1 pC/N do 100 pC/N CMC 3,0 %\nPorównanie z czujnikiem wzorcowym z wykorzystaniem znanej masy reakcyjnej (ČSN ISO 16063-22)","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czułość czujników udarów mechanicznych o przebiegu półsinusoidalnym / młotki udarowe Wzorcowanie – ruch mechaniczny Porównanie z czujnikiem wzorcowym z wykorzystaniem znanej masy reakcyjnej (ČSN ISO 16063-22) od 0,1 mV/N do 100 mV/N CMC 3,0 % od 0,1 pC/N do 100 pC/N CMC 3,0 % Citlivost snímačů mechanických rázů půlsinusového průběhu / rázová kladívka Kalibrace – mechanický pohyb Porovnání s etalonovým snímačem s využitím známé reakční hmoty (ČSN ISO 16063-22) 0,1 mV/N až 100 mV/N CMC 3,0 % 0,1 pC/N až 100 pC/N CMC 3,0 % KP-01 Czulosc czujnikow udarow mechanicznych o przebiegu polsinusoidalnym / mlotki udarowe Wzorcowanie – ruch mechaniczny Porownanie z czujnikiem wzorcowym z wykorzystaniem znanej masy reakcyjnej (CSN ISO 16063-22) od 0,1 mV/N do 100 mV/N CMC 3,0 % od 0,1 pC/N do 100 pC/N CMC 3,0 % Citlivost snimacu mechanickych razu pulsinusoveho prubehu / razova kladivka Kalibrace – mechanicky pohyb Porovnani s etalonovym snimacem s vyuzitim zname reakcni hmoty (CSN ISO 16063-22) 0,1 mV/N az 100 mV/N CMC 3,0 % 0,1 pC/N az 100 pC/N CMC 3,0 % KP-01","search_en":"Sensitivity of half-sine wave mechanical shock sensors / shock hammers Calibration – mechanical motion Comparison with a reference sensor using a known reaction mass (ČSN ISO 16063-22) 0,1 mV/N to 100 mV/N CMC 3,0 % 0,1 pC/N to 100 pC/N CMC 3,0 % KP-01","search_zh":"半正弦机械冲击传感器灵敏度 / 冲击力锤 校准 – 机械运动 利用已知反作用质量与标准传感器比较（ČSN ISO 16063-22） 0,1 mV/N 至 100 mV/N CMC 3,0 % 0,1 pC/N 至 100 pC/N CMC 3,0 % KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"76a801df917dceffd833029b","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / Źródła i mierniki napięcia stałego, woltomierze, multimetry, analizatory sygnałów, wibrometry, kontrolery systemów do badań wibracyjnych","test_object_en":"DC Voltage / DC voltage sources and meters, voltmeters, multimeters, signal analyzers, vibration meters, vibration test system controllers","test_object_zh":"直流电压 / 直流电压源和测量仪器、电压表、万用表、信号分析仪、测振仪、振动试验系统控制器","test_object_cs":"Stejnosměrné napětí / Zdroje a měřidla stejnosměrného napětí, voltmetry, multimetry, signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"od 100 mV do 1 V","cmc":"0,010 % + 0,020 mV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,010 % + 0,10 mV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,010 % + 1,0 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"100 mV to 1 V","cmc":"0,010 % + 0,020 mV"},{"name":"","range":"1 V to 10 V","cmc":"0,010 % + 0,10 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,010 % + 1,0 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"100 mV 至 1 V","cmc":"0,010 % + 0,020 mV"},{"name":"","range":"1 V 至 10 V","cmc":"0,010 % + 0,10 mV"},{"name":"","range":"10 V 至 100 V","cmc":"0,010 % + 1,0 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"100 mV až 1 V","cmc":"0,010 % + 0,020 mV"},{"name":"","range":"1 V až 10 V","cmc":"0,010 % + 0,10 mV"},{"name":"","range":"10 V až 100 V","cmc":"0,010 % + 1,0 mV"}],"technique":"Pomiar bezpośredni lub porównanie z multimetrem wzorcowym","technique_en":"Direct measurement or comparison with a reference multimeter","technique_zh":"直接测量或与标准万用表比较","technique_cs":"Přímé měření nebo porovnání s etalonovým multimetrem","techniques":["Pomiar bezpośredni lub porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement or comparison with a reference multimeter"],"techniques_zh":["直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření nebo porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,010 % + 0,010 mV\nod 100 mV do 1 V CMC 0,010 % + 0,020 mV\nod 1 V do 10 V CMC 0,010 % + 0,10 mV\nod 10 V do 100 V CMC 0,010 % + 1,0 mV\nPomiar bezpośredni lub porównanie z multimetrem wzorcowym","reference":"KP-03","norm_bases":["KP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / Źródła i mierniki napięcia stałego, woltomierze, multimetry, analizatory sygnałów, wibrometry, kontrolery systemów do badań wibracyjnych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni lub porównanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,010 % + 0,010 mV od 100 mV do 1 V CMC 0,010 % + 0,020 mV od 1 V do 10 V CMC 0,010 % + 0,10 mV od 10 V do 100 V CMC 0,010 % + 1,0 mV Stejnosměrné napětí / Zdroje a měřidla stejnosměrného napětí, voltmetry, multimetry, signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů Kalibrace – elektrické veličiny Přímé měření nebo porovnání s etalonovým multimetrem 0 mV až 100 mV CMC 0,010 % + 0,010 mV 100 mV až 1 V CMC 0,010 % + 0,020 mV 1 V až 10 V CMC 0,010 % + 0,10 mV 10 V až 100 V CMC 0,010 % + 1,0 mV KP-03 Napiecie stale / Zrodla i mierniki napiecia stalego, woltomierze, multimetry, analizatory sygnalow, wibrometry, kontrolery systemow do badan wibracyjnych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni lub porownanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,010 % + 0,010 mV od 100 mV do 1 V CMC 0,010 % + 0,020 mV od 1 V do 10 V CMC 0,010 % + 0,10 mV od 10 V do 100 V CMC 0,010 % + 1,0 mV Stejnosmerne napeti / Zdroje a meridla stejnosmerneho napeti, voltmetry, multimetry, signalove analyzatory, vibrometry, kontrolery vibracnich testovacich systemu Kalibrace – elektricke veliciny Prime mereni nebo porovnani s etalonovym multimetrem 0 mV az 100 mV CMC 0,010 % + 0,010 mV 100 mV az 1 V CMC 0,010 % + 0,020 mV 1 V az 10 V CMC 0,010 % + 0,10 mV 10 V az 100 V CMC 0,010 % + 1,0 mV KP-03","search_en":"DC Voltage / DC voltage sources and meters, voltmeters, multimeters, signal analyzers, vibration meters, vibration test system controllers Calibration – electrical quantities Direct measurement or comparison with a reference multimeter 0 mV to 100 mV CMC 0,010 % + 0,010 mV 100 mV to 1 V CMC 0,010 % + 0,020 mV 1 V to 10 V CMC 0,010 % + 0,10 mV 10 V to 100 V CMC 0,010 % + 1,0 mV KP-03","search_zh":"直流电压 / 直流电压源和测量仪器、电压表、万用表、信号分析仪、测振仪、振动试验系统控制器 校准 – 电学量 直接测量或与标准万用表比较 0 mV 至 100 mV CMC 0,010 % + 0,010 mV 100 mV 至 1 V CMC 0,010 % + 0,020 mV 1 V 至 10 V CMC 0,010 % + 0,10 mV 10 V 至 100 V CMC 0,010 % + 1,0 mV KP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"08d7416f312225499e68ac5b","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / Źródła i mierniki prądu stałego, amperomierze, multimetry","test_object_en":"DC current / DC current sources and meters, ammeters, multimeters","test_object_zh":"直流电流 / 直流电流源和测量仪器、电流表、万用表","test_object_cs":"Stejnosměrný proud / Zdroje a měřidla stejnosměrného proudu, ampérmetry, multimetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mA do 1 mA","cmc":"0,10 % + 0,10 uA"},{"name":"","range":"od 1 mA do 10 mA","cmc":"0,10 % + 5,0 uA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,10 % + 10 uA"},{"name":"","range":"od 100 mA do 1 A","cmc":"0,20 % + 0,20 mA"}],"parameters_en":[{"name":"","range":"0 mA to 1 mA","cmc":"0,10 % + 0,10 uA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,10 % + 5,0 uA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,10 % + 10 uA"},{"name":"","range":"100 mA to 1 A","cmc":"0,20 % + 0,20 mA"}],"parameters_zh":[{"name":"","range":"0 mA 至 1 mA","cmc":"0,10 % + 0,10 uA"},{"name":"","range":"1 mA 至 10 mA","cmc":"0,10 % + 5,0 uA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,10 % + 10 uA"},{"name":"","range":"100 mA 至 1 A","cmc":"0,20 % + 0,20 mA"}],"parameters_cs":[{"name":"","range":"0 mA až 1 mA","cmc":"0,10 % + 0,10 uA"},{"name":"","range":"1 mA až 10 mA","cmc":"0,10 % + 5,0 uA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,10 % + 10 uA"},{"name":"","range":"100 mA až 1 A","cmc":"0,20 % + 0,20 mA"}],"technique":"Pomiar bezpośredni lub porównanie z multimetrem wzorcowym","technique_en":"Direct measurement or comparison with a reference multimeter","technique_zh":"直接测量或与标准万用表比较","technique_cs":"Přímé měření nebo porovnání s etalonovým multimetrem","techniques":["Pomiar bezpośredni lub porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement or comparison with a reference multimeter"],"techniques_zh":["直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření nebo porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mA do 1 mA CMC 0,10 % + 0,10 uA\nod 1 mA do 10 mA CMC 0,10 % + 5,0 uA\nod 10 mA do 100 mA CMC 0,10 % + 10 uA\nod 100 mA do 1 A CMC 0,20 % + 0,20 mA\nPomiar bezpośredni lub porównanie z multimetrem wzorcowym","reference":"KP-03","norm_bases":["KP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Źródła i mierniki prądu stałego, amperomierze, multimetry Wzorcowanie – wielkości elektryczne Pomiar bezpośredni lub porównanie z multimetrem wzorcowym od 0 mA do 1 mA CMC 0,10 % + 0,10 uA od 1 mA do 10 mA CMC 0,10 % + 5,0 uA od 10 mA do 100 mA CMC 0,10 % + 10 uA od 100 mA do 1 A CMC 0,20 % + 0,20 mA Stejnosměrný proud / Zdroje a měřidla stejnosměrného proudu, ampérmetry, multimetry Kalibrace – elektrické veličiny Přímé měření nebo porovnání s etalonovým multimetrem 0 mA až 1 mA CMC 0,10 % + 0,10 uA 1 mA až 10 mA CMC 0,10 % + 5,0 uA 10 mA až 100 mA CMC 0,10 % + 10 uA 100 mA až 1 A CMC 0,20 % + 0,20 mA KP-03 Prad staly / Zrodla i mierniki pradu stalego, amperomierze, multimetry Wzorcowanie – wielkosci elektryczne Pomiar bezposredni lub porownanie z multimetrem wzorcowym od 0 mA do 1 mA CMC 0,10 % + 0,10 uA od 1 mA do 10 mA CMC 0,10 % + 5,0 uA od 10 mA do 100 mA CMC 0,10 % + 10 uA od 100 mA do 1 A CMC 0,20 % + 0,20 mA Stejnosmerny proud / Zdroje a meridla stejnosmerneho proudu, ampermetry, multimetry Kalibrace – elektricke veliciny Prime mereni nebo porovnani s etalonovym multimetrem 0 mA az 1 mA CMC 0,10 % + 0,10 uA 1 mA az 10 mA CMC 0,10 % + 5,0 uA 10 mA az 100 mA CMC 0,10 % + 10 uA 100 mA az 1 A CMC 0,20 % + 0,20 mA KP-03","search_en":"DC current / DC current sources and meters, ammeters, multimeters Calibration – electrical quantities Direct measurement or comparison with a reference multimeter 0 mA to 1 mA CMC 0,10 % + 0,10 uA 1 mA to 10 mA CMC 0,10 % + 5,0 uA 10 mA to 100 mA CMC 0,10 % + 10 uA 100 mA to 1 A CMC 0,20 % + 0,20 mA KP-03","search_zh":"直流电流 / 直流电流源和测量仪器、电流表、万用表 校准 – 电学量 直接测量或与标准万用表比较 0 mA 至 1 mA CMC 0,10 % + 0,10 uA 1 mA 至 10 mA CMC 0,10 % + 5,0 uA 10 mA 至 100 mA CMC 0,10 % + 10 uA 100 mA 至 1 A CMC 0,20 % + 0,20 mA KP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b752a10badb433f2402c9b60","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"3","test_object":"Rezystancja przy prądzie stałym / Rezystory, dekady rezystancyjne, boczniki, dzielniki","test_object_en":"DC Resistance / Resistors, resistance boxes, shunts, dividers","test_object_zh":"直流电阻 / 电阻器、电阻箱、分流器、分压器","test_object_cs":"Stejnosměrný odpor / Rezistory, odporové dekády, bočníky, děliče","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 100 Ω","cmc":"0,020 % + 0,010 Ω"},{"name":"","range":"od 100 Ω do 1 kΩ","cmc":"0,020 % + 0,020 Ω"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,020 % + 0,20 Ω"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"0,020 % + 2,0 Ω"},{"name":"","range":"od 100 kΩ do 1 MΩ","cmc":"0,025 % + 20 Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,10 % + 200 Ω"}],"parameters_en":[{"name":"","range":"0 Ω to 100 Ω","cmc":"0,020 % + 0,010 Ω"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,020 % + 0,020 Ω"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,020 % + 0,20 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,020 % + 2,0 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,025 % + 20 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,10 % + 200 Ω"}],"parameters_zh":[{"name":"","range":"0 Ω 至 100 Ω","cmc":"0,020 % + 0,010 Ω"},{"name":"","range":"100 Ω 至 1 kΩ","cmc":"0,020 % + 0,020 Ω"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,020 % + 0,20 Ω"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"0,020 % + 2,0 Ω"},{"name":"","range":"100 kΩ 至 1 MΩ","cmc":"0,025 % + 20 Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,10 % + 200 Ω"}],"parameters_cs":[{"name":"","range":"0 Ω až 100 Ω","cmc":"0,020 % + 0,010 Ω"},{"name":"","range":"100 Ω až 1 kΩ","cmc":"0,020 % + 0,020 Ω"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,020 % + 0,20 Ω"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"0,020 % + 2,0 Ω"},{"name":"","range":"100 kΩ až 1 MΩ","cmc":"0,025 % + 20 Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,10 % + 200 Ω"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 100 Ω CMC 0,020 % + 0,010 Ω\nod 100 Ω do 1 kΩ CMC 0,020 % + 0,020 Ω\nod 1 kΩ do 10 kΩ CMC 0,020 % + 0,20 Ω\nod 10 kΩ do 100 kΩ CMC 0,020 % + 2,0 Ω\nod 100 kΩ do 1 MΩ CMC 0,025 % + 20 Ω\nod 1 MΩ do 10 MΩ CMC 0,10 % + 200 Ω\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP-03","norm_bases":["KP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / Rezystory, dekady rezystancyjne, boczniki, dzielniki Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 Ω do 100 Ω CMC 0,020 % + 0,010 Ω od 100 Ω do 1 kΩ CMC 0,020 % + 0,020 Ω od 1 kΩ do 10 kΩ CMC 0,020 % + 0,20 Ω od 10 kΩ do 100 kΩ CMC 0,020 % + 2,0 Ω od 100 kΩ do 1 MΩ CMC 0,025 % + 20 Ω od 1 MΩ do 10 MΩ CMC 0,10 % + 200 Ω Stejnosměrný odpor / Rezistory, odporové dekády, bočníky, děliče Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 Ω až 100 Ω CMC 0,020 % + 0,010 Ω 100 Ω až 1 kΩ CMC 0,020 % + 0,020 Ω 1 kΩ až 10 kΩ CMC 0,020 % + 0,20 Ω 10 kΩ až 100 kΩ CMC 0,020 % + 2,0 Ω 100 kΩ až 1 MΩ CMC 0,025 % + 20 Ω 1 MΩ až 10 MΩ CMC 0,10 % + 200 Ω KP-03 Rezystancja przy pradzie stalym / Rezystory, dekady rezystancyjne, boczniki, dzielniki Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 Ω do 100 Ω CMC 0,020 % + 0,010 Ω od 100 Ω do 1 kΩ CMC 0,020 % + 0,020 Ω od 1 kΩ do 10 kΩ CMC 0,020 % + 0,20 Ω od 10 kΩ do 100 kΩ CMC 0,020 % + 2,0 Ω od 100 kΩ do 1 MΩ CMC 0,025 % + 20 Ω od 1 MΩ do 10 MΩ CMC 0,10 % + 200 Ω Stejnosmerny odpor / Rezistory, odporove dekady, bocniky, delice Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 Ω az 100 Ω CMC 0,020 % + 0,010 Ω 100 Ω az 1 kΩ CMC 0,020 % + 0,020 Ω 1 kΩ az 10 kΩ CMC 0,020 % + 0,20 Ω 10 kΩ az 100 kΩ CMC 0,020 % + 2,0 Ω 100 kΩ az 1 MΩ CMC 0,025 % + 20 Ω 1 MΩ az 10 MΩ CMC 0,10 % + 200 Ω KP-03","search_en":"DC Resistance / Resistors, resistance boxes, shunts, dividers Calibration – electrical quantities Direct measurement by a reference multimeter 0 Ω to 100 Ω CMC 0,020 % + 0,010 Ω 100 Ω to 1 kΩ CMC 0,020 % + 0,020 Ω 1 kΩ to 10 kΩ CMC 0,020 % + 0,20 Ω 10 kΩ to 100 kΩ CMC 0,020 % + 2,0 Ω 100 kΩ to 1 MΩ CMC 0,025 % + 20 Ω 1 MΩ to 10 MΩ CMC 0,10 % + 200 Ω KP-03","search_zh":"直流电阻 / 电阻器、电阻箱、分流器、分压器 校准 – 电学量 用标准万用表直接测量 0 Ω 至 100 Ω CMC 0,020 % + 0,010 Ω 100 Ω 至 1 kΩ CMC 0,020 % + 0,020 Ω 1 kΩ 至 10 kΩ CMC 0,020 % + 0,20 Ω 10 kΩ 至 100 kΩ CMC 0,020 % + 2,0 Ω 100 kΩ 至 1 MΩ CMC 0,025 % + 20 Ω 1 MΩ 至 10 MΩ CMC 0,10 % + 200 Ω KP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5de417b44b7a3b1ff93e904d","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"4","test_object":"Napięcie przemienne / Źródła i mierniki napięcia przemiennego, woltomierze napięcia przemiennego, multimetry, analizatory sygnałów, wibrometry, systemy wzorcowania czujników drgań, generatory sygnałów, kontrolery systemów do badań wibracyjnych","test_object_en":"AC Voltage / AC voltage sources and meters, AC voltmeters, multimeters, signal analyzers, vibration meters, vibration sensor calibration systems, signal generators, controllers for vibration test systems","test_object_zh":"交流电压 / 交流电压源和测量仪器、交流电压表、万用表、信号分析仪、测振仪、振动传感器校准系统、信号发生器、振动试验系统控制器","test_object_cs":"Střídavé napětí / Zdroje a měřidla střídavého napětí, střídavé voltmetry, multimetry, signálové analyzátory, vibrometry, kalibrační systémy snímačů vibrací, signálové generátory, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 20 kHz","range":"od 1 mV do 100 mV","cmc":"0,10 % + 0,050 mV"},{"name":"20 kHz do 50 kHz","range":"od 1 mV do 100 mV","cmc":"0,20 % + 0,10 mV"},{"name":"50 kHz do 100 kHz","range":"od 1 mV do 100 mV","cmc":"0,80 % + 0,15 mV"},{"name":"10 Hz do 20 kHz","range":"od 100 mV do 1 V","cmc":"0,10 % + 0,50 mV"},{"name":"20 kHz do 50 kHz","range":"od 100 mV do 1 V","cmc":"0,20 % + 1,0 mV"},{"name":"50 kHz do 100 kHz","range":"od 100 mV do 1 V","cmc":"0,80 % + 1,5 mV"},{"name":"10 Hz do 20 kHz","range":"od 1 V do 10 V","cmc":"0,10 % + 5,0 mV"},{"name":"20 kHz do 50 kHz","range":"od 1 V do 10 V","cmc":"0,20 % + 10 mV"},{"name":"50 kHz do 100 kHz","range":"od 1 V do 10 V","cmc":"0,80 % + 15 mV"},{"name":"10 Hz do 20 kHz","range":"od 10 V do 100 V","cmc":"0,10 % + 50 mV"},{"name":"20 kHz do 50 kHz","range":"od 10 V do 100 V","cmc":"0,20 % + 100 mV"},{"name":"50 kHz do 100 kHz","range":"od 10 V do 100 V","cmc":"0,80 % + 150 mV"}],"parameters_en":[{"name":"10 Hz to 20 kHz","range":"1 mV to 100 mV","cmc":"0,10 % + 0,050 mV"},{"name":"20 kHz to 50 kHz","range":"1 mV to 100 mV","cmc":"0,20 % + 0,10 mV"},{"name":"50 kHz to 100 kHz","range":"1 mV to 100 mV","cmc":"0,80 % + 0,15 mV"},{"name":"10 Hz to 20 kHz","range":"100 mV to 1 V","cmc":"0,10 % + 0,50 mV"},{"name":"20 kHz to 50 kHz","range":"100 mV to 1 V","cmc":"0,20 % + 1,0 mV"},{"name":"50 kHz to 100 kHz","range":"100 mV to 1 V","cmc":"0,80 % + 1,5 mV"},{"name":"10 Hz to 20 kHz","range":"1 V to 10 V","cmc":"0,10 % + 5,0 mV"},{"name":"20 kHz to 50 kHz","range":"1 V to 10 V","cmc":"0,20 % + 10 mV"},{"name":"50 kHz to 100 kHz","range":"1 V to 10 V","cmc":"0,80 % + 15 mV"},{"name":"10 Hz to 20 kHz","range":"10 V to 100 V","cmc":"0,10 % + 50 mV"},{"name":"20 kHz to 50 kHz","range":"10 V to 100 V","cmc":"0,20 % + 100 mV"},{"name":"50 kHz to 100 kHz","range":"10 V to 100 V","cmc":"0,80 % + 150 mV"}],"parameters_zh":[{"name":"10 Hz 至 20 kHz","range":"1 mV 至 100 mV","cmc":"0,10 % + 0,050 mV"},{"name":"20 kHz 至 50 kHz","range":"1 mV 至 100 mV","cmc":"0,20 % + 0,10 mV"},{"name":"50 kHz 至 100 kHz","range":"1 mV 至 100 mV","cmc":"0,80 % + 0,15 mV"},{"name":"10 Hz 至 20 kHz","range":"100 mV 至 1 V","cmc":"0,10 % + 0,50 mV"},{"name":"20 kHz 至 50 kHz","range":"100 mV 至 1 V","cmc":"0,20 % + 1,0 mV"},{"name":"50 kHz 至 100 kHz","range":"100 mV 至 1 V","cmc":"0,80 % + 1,5 mV"},{"name":"10 Hz 至 20 kHz","range":"1 V 至 10 V","cmc":"0,10 % + 5,0 mV"},{"name":"20 kHz 至 50 kHz","range":"1 V 至 10 V","cmc":"0,20 % + 10 mV"},{"name":"50 kHz 至 100 kHz","range":"1 V 至 10 V","cmc":"0,80 % + 15 mV"},{"name":"10 Hz 至 20 kHz","range":"10 V 至 100 V","cmc":"0,10 % + 50 mV"},{"name":"20 kHz 至 50 kHz","range":"10 V 至 100 V","cmc":"0,20 % + 100 mV"},{"name":"50 kHz 至 100 kHz","range":"10 V 至 100 V","cmc":"0,80 % + 150 mV"}],"parameters_cs":[{"name":"10 Hz až 20 kHz","range":"1 mV až 100 mV","cmc":"0,10 % + 0,050 mV"},{"name":"20 kHz až 50 kHz","range":"1 mV až 100 mV","cmc":"0,20 % + 0,10 mV"},{"name":"50 kHz až 100 kHz","range":"1 mV až 100 mV","cmc":"0,80 % + 0,15 mV"},{"name":"10 Hz až 20 kHz","range":"100 mV až 1 V","cmc":"0,10 % + 0,50 mV"},{"name":"20 kHz až 50 kHz","range":"100 mV až 1 V","cmc":"0,20 % + 1,0 mV"},{"name":"50 kHz až 100 kHz","range":"100 mV až 1 V","cmc":"0,80 % + 1,5 mV"},{"name":"10 Hz až 20 kHz","range":"1 V až 10 V","cmc":"0,10 % + 5,0 mV"},{"name":"20 kHz až 50 kHz","range":"1 V až 10 V","cmc":"0,20 % + 10 mV"},{"name":"50 kHz až 100 kHz","range":"1 V až 10 V","cmc":"0,80 % + 15 mV"},{"name":"10 Hz až 20 kHz","range":"10 V až 100 V","cmc":"0,10 % + 50 mV"},{"name":"20 kHz až 50 kHz","range":"10 V až 100 V","cmc":"0,20 % + 100 mV"},{"name":"50 kHz až 100 kHz","range":"10 V až 100 V","cmc":"0,80 % + 150 mV"}],"technique":"Pomiar bezpośredni lub porównanie z multimetrem wzorcowym","technique_en":"Direct measurement or comparison with a reference multimeter","technique_zh":"直接测量或与标准万用表比较","technique_cs":"Přímé měření nebo porovnání s etalonovým multimetrem","techniques":["Pomiar bezpośredni lub porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement or comparison with a reference multimeter"],"techniques_zh":["直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření nebo porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 20 kHz od 1 mV do 100 mV CMC 0,10 % + 0,050 mV\n20 kHz do 50 kHz od 1 mV do 100 mV CMC 0,20 % + 0,10 mV\n50 kHz do 100 kHz od 1 mV do 100 mV CMC 0,80 % + 0,15 mV\n10 Hz do 20 kHz od 100 mV do 1 V CMC 0,10 % + 0,50 mV\n20 kHz do 50 kHz od 100 mV do 1 V CMC 0,20 % + 1,0 mV\n50 kHz do 100 kHz od 100 mV do 1 V CMC 0,80 % + 1,5 mV\n10 Hz do 20 kHz od 1 V do 10 V CMC 0,10 % + 5,0 mV\n20 kHz do 50 kHz od 1 V do 10 V CMC 0,20 % + 10 mV\n50 kHz do 100 kHz od 1 V do 10 V CMC 0,80 % + 15 mV\n10 Hz do 20 kHz od 10 V do 100 V CMC 0,10 % + 50 mV\n20 kHz do 50 kHz od 10 V do 100 V CMC 0,20 % + 100 mV\n50 kHz do 100 kHz od 10 V do 100 V CMC 0,80 % + 150 mV\nPomiar bezpośredni lub porównanie z multimetrem wzorcowym","reference":"KP-03","norm_bases":["KP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / Źródła i mierniki napięcia przemiennego, woltomierze napięcia przemiennego, multimetry, analizatory sygnałów, wibrometry, systemy wzorcowania czujników drgań, generatory sygnałów, kontrolery systemów do badań wibracyjnych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni lub porównanie z multimetrem wzorcowym 10 Hz do 20 kHz od 1 mV do 100 mV CMC 0,10 % + 0,050 mV 20 kHz do 50 kHz od 1 mV do 100 mV CMC 0,20 % + 0,10 mV 50 kHz do 100 kHz od 1 mV do 100 mV CMC 0,80 % + 0,15 mV 10 Hz do 20 kHz od 100 mV do 1 V CMC 0,10 % + 0,50 mV 20 kHz do 50 kHz od 100 mV do 1 V CMC 0,20 % + 1,0 mV 50 kHz do 100 kHz od 100 mV do 1 V CMC 0,80 % + 1,5 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,10 % + 5,0 mV 20 kHz do 50 kHz od 1 V do 10 V CMC 0,20 % + 10 mV 50 kHz do 100 kHz od 1 V do 10 V CMC 0,80 % + 15 mV 10 Hz do 20 kHz od 10 V do 100 V CMC 0,10 % + 50 mV 20 kHz do 50 kHz od 10 V do 100 V CMC 0,20 % + 100 mV 50 kHz do 100 kHz od 10 V do 100 V CMC 0,80 % + 150 mV Střídavé napětí / Zdroje a měřidla střídavého napětí, střídavé voltmetry, multimetry, signálové analyzátory, vibrometry, kalibrační systémy snímačů vibrací, signálové generátory, kontroléry vibračních testovacích systémů Kalibrace – elektrické veličiny Přímé měření nebo porovnání s etalonovým multimetrem 10 Hz až 20 kHz 1 mV až 100 mV CMC 0,10 % + 0,050 mV 20 kHz až 50 kHz 1 mV až 100 mV CMC 0,20 % + 0,10 mV 50 kHz až 100 kHz 1 mV až 100 mV CMC 0,80 % + 0,15 mV 10 Hz až 20 kHz 100 mV až 1 V CMC 0,10 % + 0,50 mV 20 kHz až 50 kHz 100 mV až 1 V CMC 0,20 % + 1,0 mV 50 kHz až 100 kHz 100 mV až 1 V CMC 0,80 % + 1,5 mV 10 Hz až 20 kHz 1 V až 10 V CMC 0,10 % + 5,0 mV 20 kHz až 50 kHz 1 V až 10 V CMC 0,20 % + 10 mV 50 kHz až 100 kHz 1 V až 10 V CMC 0,80 % + 15 mV 10 Hz až 20 kHz 10 V až 100 V CMC 0,10 % + 50 mV 20 kHz až 50 kHz 10 V až 100 V CMC 0,20 % + 100 mV 50 kHz až 100 kHz 10 V až 100 V CMC 0,80 % + 150 mV KP-03 Napiecie przemienne / Zrodla i mierniki napiecia przemiennego, woltomierze napiecia przemiennego, multimetry, analizatory sygnalow, wibrometry, systemy wzorcowania czujnikow drgan, generatory sygnalow, kontrolery systemow do badan wibracyjnych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni lub porownanie z multimetrem wzorcowym 10 Hz do 20 kHz od 1 mV do 100 mV CMC 0,10 % + 0,050 mV 20 kHz do 50 kHz od 1 mV do 100 mV CMC 0,20 % + 0,10 mV 50 kHz do 100 kHz od 1 mV do 100 mV CMC 0,80 % + 0,15 mV 10 Hz do 20 kHz od 100 mV do 1 V CMC 0,10 % + 0,50 mV 20 kHz do 50 kHz od 100 mV do 1 V CMC 0,20 % + 1,0 mV 50 kHz do 100 kHz od 100 mV do 1 V CMC 0,80 % + 1,5 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,10 % + 5,0 mV 20 kHz do 50 kHz od 1 V do 10 V CMC 0,20 % + 10 mV 50 kHz do 100 kHz od 1 V do 10 V CMC 0,80 % + 15 mV 10 Hz do 20 kHz od 10 V do 100 V CMC 0,10 % + 50 mV 20 kHz do 50 kHz od 10 V do 100 V CMC 0,20 % + 100 mV 50 kHz do 100 kHz od 10 V do 100 V CMC 0,80 % + 150 mV Stridave napeti / Zdroje a meridla stridaveho napeti, stridave voltmetry, multimetry, signalove analyzatory, vibrometry, kalibracni systemy snimacu vibraci, signalove generatory, kontrolery vibracnich testovacich systemu Kalibrace – elektricke veliciny Prime mereni nebo porovnani s etalonovym multimetrem 10 Hz az 20 kHz 1 mV az 100 mV CMC 0,10 % + 0,050 mV 20 kHz az 50 kHz 1 mV az 100 mV CMC 0,20 % + 0,10 mV 50 kHz az 100 kHz 1 mV az 100 mV CMC 0,80 % + 0,15 mV 10 Hz az 20 kHz 100 mV az 1 V CMC 0,10 % + 0,50 mV 20 kHz az 50 kHz 100 mV az 1 V CMC 0,20 % + 1,0 mV 50 kHz az 100 kHz 100 mV az 1 V CMC 0,80 % + 1,5 mV 10 Hz az 20 kHz 1 V az 10 V CMC 0,10 % + 5,0 mV 20 kHz az 50 kHz 1 V az 10 V CMC 0,20 % + 10 mV 50 kHz az 100 kHz 1 V az 10 V CMC 0,80 % + 15 mV 10 Hz az 20 kHz 10 V az 100 V CMC 0,10 % + 50 mV 20 kHz az 50 kHz 10 V az 100 V CMC 0,20 % + 100 mV 50 kHz az 100 kHz 10 V az 100 V CMC 0,80 % + 150 mV KP-03","search_en":"AC Voltage / AC voltage sources and meters, AC voltmeters, multimeters, signal analyzers, vibration meters, vibration sensor calibration systems, signal generators, controllers for vibration test systems Calibration – electrical quantities Direct measurement or comparison with a reference multimeter 10 Hz to 20 kHz 1 mV to 100 mV CMC 0,10 % + 0,050 mV 20 kHz to 50 kHz 1 mV to 100 mV CMC 0,20 % + 0,10 mV 50 kHz to 100 kHz 1 mV to 100 mV CMC 0,80 % + 0,15 mV 10 Hz to 20 kHz 100 mV to 1 V CMC 0,10 % + 0,50 mV 20 kHz to 50 kHz 100 mV to 1 V CMC 0,20 % + 1,0 mV 50 kHz to 100 kHz 100 mV to 1 V CMC 0,80 % + 1,5 mV 10 Hz to 20 kHz 1 V to 10 V CMC 0,10 % + 5,0 mV 20 kHz to 50 kHz 1 V to 10 V CMC 0,20 % + 10 mV 50 kHz to 100 kHz 1 V to 10 V CMC 0,80 % + 15 mV 10 Hz to 20 kHz 10 V to 100 V CMC 0,10 % + 50 mV 20 kHz to 50 kHz 10 V to 100 V CMC 0,20 % + 100 mV 50 kHz to 100 kHz 10 V to 100 V CMC 0,80 % + 150 mV KP-03","search_zh":"交流电压 / 交流电压源和测量仪器、交流电压表、万用表、信号分析仪、测振仪、振动传感器校准系统、信号发生器、振动试验系统控制器 校准 – 电学量 直接测量或与标准万用表比较 10 Hz 至 20 kHz 1 mV 至 100 mV CMC 0,10 % + 0,050 mV 20 kHz 至 50 kHz 1 mV 至 100 mV CMC 0,20 % + 0,10 mV 50 kHz 至 100 kHz 1 mV 至 100 mV CMC 0,80 % + 0,15 mV 10 Hz 至 20 kHz 100 mV 至 1 V CMC 0,10 % + 0,50 mV 20 kHz 至 50 kHz 100 mV 至 1 V CMC 0,20 % + 1,0 mV 50 kHz 至 100 kHz 100 mV 至 1 V CMC 0,80 % + 1,5 mV 10 Hz 至 20 kHz 1 V 至 10 V CMC 0,10 % + 5,0 mV 20 kHz 至 50 kHz 1 V 至 10 V CMC 0,20 % + 10 mV 50 kHz 至 100 kHz 1 V 至 10 V CMC 0,80 % + 15 mV 10 Hz 至 20 kHz 10 V 至 100 V CMC 0,10 % + 50 mV 20 kHz 至 50 kHz 10 V 至 100 V CMC 0,20 % + 100 mV 50 kHz 至 100 kHz 10 V 至 100 V CMC 0,80 % + 150 mV KP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"52316f1e3ee5dd1d42cc4d4a","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / Generatory sygnałów, liczniki, multimetry, analizatory sygnałów, wibrometry, systemy wzorcujące, kontrolery systemów do badań wibracyjnych","test_object_en":"Frequency / Signal generators, counters, multimeters, signal analyzers, vibration meters, calibration systems, vibration test system controllers","test_object_zh":"频率 / 信号发生器、计数器、万用表、信号分析仪、测振仪、校准系统、振动试验系统控制器","test_object_cs":"Kmitočet / Signálové generátory, čítače, multimetry, signálové analyzátory, vibrometry, kalibrační systémy, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"15 mV do 250 mV","range":"od 0,1 Hz do 100 kHz","cmc":"2,0·10⁻⁴/f"},{"name":"250 mV do 50 V","range":"od 0,1 Hz do 100 kHz","cmc":"2,0·10⁻⁵/f"},{"name":"15 mV do 250 mV","range":"od 100 kHz do 1 MHz","cmc":"2,0·10⁻⁹"},{"name":"250 mV do 50 V","range":"od 100 kHz do 1 MHz","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV do 50 V","range":"od 1 MHz do 10 MHz","cmc":"2,0·10⁻¹⁰"}],"parameters_en":[{"name":"15 mV to 250 mV","range":"0,1 Hz to 100 kHz","cmc":"2,0·10⁻⁴/f"},{"name":"250 mV to 50 V","range":"0,1 Hz to 100 kHz","cmc":"2,0·10⁻⁵/f"},{"name":"15 mV to 250 mV","range":"100 kHz to 1 MHz","cmc":"2,0·10⁻⁹"},{"name":"250 mV to 50 V","range":"100 kHz to 1 MHz","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV to 50 V","range":"1 MHz to 10 MHz","cmc":"2,0·10⁻¹⁰"}],"parameters_zh":[{"name":"15 mV 至 250 mV","range":"0,1 Hz 至 100 kHz","cmc":"2,0·10⁻⁴/f"},{"name":"250 mV 至 50 V","range":"0,1 Hz 至 100 kHz","cmc":"2,0·10⁻⁵/f"},{"name":"15 mV 至 250 mV","range":"100 kHz 至 1 MHz","cmc":"2,0·10⁻⁹"},{"name":"250 mV 至 50 V","range":"100 kHz 至 1 MHz","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV 至 50 V","range":"1 MHz 至 10 MHz","cmc":"2,0·10⁻¹⁰"}],"parameters_cs":[{"name":"15 mV až 250 mV","range":"0,1 Hz až 100 kHz","cmc":"2,0·10⁻⁴/f"},{"name":"250 mV až 50 V","range":"0,1 Hz až 100 kHz","cmc":"2,0·10⁻⁵/f"},{"name":"15 mV až 250 mV","range":"100 kHz až 1 MHz","cmc":"2,0·10⁻⁹"},{"name":"250 mV až 50 V","range":"100 kHz až 1 MHz","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV až 50 V","range":"1 MHz až 10 MHz","cmc":"2,0·10⁻¹⁰"}],"technique":"Pomiar bezpośredni lub porównanie z licznikiem wzorcowym","technique_en":"Direct measurement or comparison with a reference counter","technique_zh":"直接测量或与标准计数器比较","technique_cs":"Přímé měření nebo porovnání s etalonovým čítačem","techniques":["Pomiar bezpośredni lub porównanie z licznikiem wzorcowym"],"techniques_en":["Direct measurement or comparison with a reference counter"],"techniques_zh":["直接测量或与标准计数器比较"],"techniques_cs":["Přímé měření nebo porovnání s etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\n15 mV do 250 mV od 0,1 Hz do 100 kHz CMC 2,0·10⁻⁴/f\n250 mV do 50 V od 0,1 Hz do 100 kHz CMC 2,0·10⁻⁵/f\n15 mV do 250 mV od 100 kHz do 1 MHz CMC 2,0·10⁻⁹\n250 mV do 50 V od 100 kHz do 1 MHz CMC 2,0·10⁻¹⁰\n15 mV do 50 V od 1 MHz do 10 MHz CMC 2,0·10⁻¹⁰\nPomiar bezpośredni lub porównanie z licznikiem wzorcowym","reference":"KP-03","norm_bases":["KP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":"f – wartość częstotliwości w Hz (uwaga 4).","note_en":"f – frequency value in Hz (note 4).","note_zh":"f – 频率值，单位 Hz（注 4）。","note_cs":"f – hodnota frekvence v Hz (pozn. 4).","search_text":"Częstotliwość / Generatory sygnałów, liczniki, multimetry, analizatory sygnałów, wibrometry, systemy wzorcujące, kontrolery systemów do badań wibracyjnych Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni lub porównanie z licznikiem wzorcowym 15 mV do 250 mV od 0,1 Hz do 100 kHz CMC 2,0·10⁻⁴/f 250 mV do 50 V od 0,1 Hz do 100 kHz CMC 2,0·10⁻⁵/f 15 mV do 250 mV od 100 kHz do 1 MHz CMC 2,0·10⁻⁹ 250 mV do 50 V od 100 kHz do 1 MHz CMC 2,0·10⁻¹⁰ 15 mV do 50 V od 1 MHz do 10 MHz CMC 2,0·10⁻¹⁰ Kmitočet / Signálové generátory, čítače, multimetry, signálové analyzátory, vibrometry, kalibrační systémy, kontroléry vibračních testovacích systémů Kalibrace – veličiny času a frekvence Přímé měření nebo porovnání s etalonovým čítačem 15 mV až 250 mV 0,1 Hz až 100 kHz CMC 2,0·10⁻⁴/f 250 mV až 50 V 0,1 Hz až 100 kHz CMC 2,0·10⁻⁵/f 15 mV až 250 mV 100 kHz až 1 MHz CMC 2,0·10⁻⁹ 250 mV až 50 V 100 kHz až 1 MHz CMC 2,0·10⁻¹⁰ 15 mV až 50 V 1 MHz až 10 MHz CMC 2,0·10⁻¹⁰ KP-03 Czestotliwosc / Generatory sygnalow, liczniki, multimetry, analizatory sygnalow, wibrometry, systemy wzorcujace, kontrolery systemow do badan wibracyjnych Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni lub porownanie z licznikiem wzorcowym 15 mV do 250 mV od 0,1 Hz do 100 kHz CMC 2,0·10⁻⁴/f 250 mV do 50 V od 0,1 Hz do 100 kHz CMC 2,0·10⁻⁵/f 15 mV do 250 mV od 100 kHz do 1 MHz CMC 2,0·10⁻⁹ 250 mV do 50 V od 100 kHz do 1 MHz CMC 2,0·10⁻¹⁰ 15 mV do 50 V od 1 MHz do 10 MHz CMC 2,0·10⁻¹⁰ Kmitocet / Signalove generatory, citace, multimetry, signalove analyzatory, vibrometry, kalibracni systemy, kontrolery vibracnich testovacich systemu Kalibrace – veliciny casu a frekvence Prime mereni nebo porovnani s etalonovym citacem 15 mV az 250 mV 0,1 Hz az 100 kHz CMC 2,0·10⁻⁴/f 250 mV az 50 V 0,1 Hz az 100 kHz CMC 2,0·10⁻⁵/f 15 mV az 250 mV 100 kHz az 1 MHz CMC 2,0·10⁻⁹ 250 mV az 50 V 100 kHz az 1 MHz CMC 2,0·10⁻¹⁰ 15 mV az 50 V 1 MHz az 10 MHz CMC 2,0·10⁻¹⁰ KP-03","search_en":"Frequency / Signal generators, counters, multimeters, signal analyzers, vibration meters, calibration systems, vibration test system controllers Calibration – time and frequency quantities Direct measurement or comparison with a reference counter 15 mV to 250 mV 0,1 Hz to 100 kHz CMC 2,0·10⁻⁴/f 250 mV to 50 V 0,1 Hz to 100 kHz CMC 2,0·10⁻⁵/f 15 mV to 250 mV 100 kHz to 1 MHz CMC 2,0·10⁻⁹ 250 mV to 50 V 100 kHz to 1 MHz CMC 2,0·10⁻¹⁰ 15 mV to 50 V 1 MHz to 10 MHz CMC 2,0·10⁻¹⁰ KP-03","search_zh":"频率 / 信号发生器、计数器、万用表、信号分析仪、测振仪、校准系统、振动试验系统控制器 校准 – 时间和频率量 直接测量或与标准计数器比较 15 mV 至 250 mV 0,1 Hz 至 100 kHz CMC 2,0·10⁻⁴/f 250 mV 至 50 V 0,1 Hz 至 100 kHz CMC 2,0·10⁻⁵/f 15 mV 至 250 mV 100 kHz 至 1 MHz CMC 2,0·10⁻⁹ 250 mV 至 50 V 100 kHz 至 1 MHz CMC 2,0·10⁻¹⁰ 15 mV 至 50 V 1 MHz 至 10 MHz CMC 2,0·10⁻¹⁰ KP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f5d4b4032ad2b8fac32f8983","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"2","test_object":"Okres / Generatory sygnałów, liczniki, multimetry, analizatory sygnałów, wibrometry, systemy wzorcujące, kontrolery systemów do badań wibracyjnych","test_object_en":"Period / Signal generators, counters, multimeters, signal analyzers, vibration meters, calibration systems, vibration test system controllers","test_object_zh":"周期 / 信号发生器、计数器、万用表、信号分析仪、测振仪、校准系统、振动试验系统控制器","test_object_cs":"Perioda / Signálové generátory, čítače, multimetry, signálové analyzátory, vibrometry, kalibrační systémy, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"15 mV do 50 V","range":"od 100 ns do 1 µs","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV do 250 mV","range":"od 1 µs do 10 µs","cmc":"2,0·10⁻⁹"},{"name":"250 mV do 50 V","range":"od 1 µs do 10 µs","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV do 250 mV","range":"od 10 µs do 10 s","cmc":"2,0·10⁻⁴·T"},{"name":"250 mV do 50 V","range":"od 10 µs do 10 s","cmc":"2,0·10⁻⁵·T"}],"parameters_en":[{"name":"15 mV to 50 V","range":"100 ns to 1 µs","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV to 250 mV","range":"1 µs to 10 µs","cmc":"2,0·10⁻⁹"},{"name":"250 mV to 50 V","range":"1 µs to 10 µs","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV to 250 mV","range":"10 µs to 10 s","cmc":"2,0·10⁻⁴·T"},{"name":"250 mV to 50 V","range":"10 µs to 10 s","cmc":"2,0·10⁻⁵·T"}],"parameters_zh":[{"name":"15 mV 至 50 V","range":"100 ns 至 1 µs","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV 至 250 mV","range":"1 µs 至 10 µs","cmc":"2,0·10⁻⁹"},{"name":"250 mV 至 50 V","range":"1 µs 至 10 µs","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV 至 250 mV","range":"10 µs 至 10 s","cmc":"2,0·10⁻⁴·T"},{"name":"250 mV 至 50 V","range":"10 µs 至 10 s","cmc":"2,0·10⁻⁵·T"}],"parameters_cs":[{"name":"15 mV až 50 V","range":"100 ns až 1 µs","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV až 250 mV","range":"1 µs až 10 µs","cmc":"2,0·10⁻⁹"},{"name":"250 mV až 50 V","range":"1 µs až 10 µs","cmc":"2,0·10⁻¹⁰"},{"name":"15 mV až 250 mV","range":"10 µs až 10 s","cmc":"2,0·10⁻⁴·T"},{"name":"250 mV až 50 V","range":"10 µs až 10 s","cmc":"2,0·10⁻⁵·T"}],"technique":"Pomiar bezpośredni lub porównanie z licznikiem wzorcowym","technique_en":"Direct measurement or comparison with a reference counter","technique_zh":"直接测量或与标准计数器比较","technique_cs":"Přímé měření nebo porovnání s etalonovým čítačem","techniques":["Pomiar bezpośredni lub porównanie z licznikiem wzorcowym"],"techniques_en":["Direct measurement or comparison with a reference counter"],"techniques_zh":["直接测量或与标准计数器比较"],"techniques_cs":["Přímé měření nebo porovnání s etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\n15 mV do 50 V od 100 ns do 1 µs CMC 2,0·10⁻¹⁰\n15 mV do 250 mV od 1 µs do 10 µs CMC 2,0·10⁻⁹\n250 mV do 50 V od 1 µs do 10 µs CMC 2,0·10⁻¹⁰\n15 mV do 250 mV od 10 µs do 10 s CMC 2,0·10⁻⁴·T\n250 mV do 50 V od 10 µs do 10 s CMC 2,0·10⁻⁵·T\nPomiar bezpośredni lub porównanie z licznikiem wzorcowym","reference":"KP-03","norm_bases":["KP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":"T – wartość okresu w s (uwaga 5).","note_en":"T – period value in s (note 5).","note_zh":"T – 周期值，单位 s（注 5）。","note_cs":"T – hodnota periody v s (pozn. 5).","search_text":"Okres / Generatory sygnałów, liczniki, multimetry, analizatory sygnałów, wibrometry, systemy wzorcujące, kontrolery systemów do badań wibracyjnych Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni lub porównanie z licznikiem wzorcowym 15 mV do 50 V od 100 ns do 1 µs CMC 2,0·10⁻¹⁰ 15 mV do 250 mV od 1 µs do 10 µs CMC 2,0·10⁻⁹ 250 mV do 50 V od 1 µs do 10 µs CMC 2,0·10⁻¹⁰ 15 mV do 250 mV od 10 µs do 10 s CMC 2,0·10⁻⁴·T 250 mV do 50 V od 10 µs do 10 s CMC 2,0·10⁻⁵·T Perioda / Signálové generátory, čítače, multimetry, signálové analyzátory, vibrometry, kalibrační systémy, kontroléry vibračních testovacích systémů Kalibrace – veličiny času a frekvence Přímé měření nebo porovnání s etalonovým čítačem 15 mV až 50 V 100 ns až 1 µs CMC 2,0·10⁻¹⁰ 15 mV až 250 mV 1 µs až 10 µs CMC 2,0·10⁻⁹ 250 mV až 50 V 1 µs až 10 µs CMC 2,0·10⁻¹⁰ 15 mV až 250 mV 10 µs až 10 s CMC 2,0·10⁻⁴·T 250 mV až 50 V 10 µs až 10 s CMC 2,0·10⁻⁵·T KP-03 Okres / Generatory sygnalow, liczniki, multimetry, analizatory sygnalow, wibrometry, systemy wzorcujace, kontrolery systemow do badan wibracyjnych Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni lub porownanie z licznikiem wzorcowym 15 mV do 50 V od 100 ns do 1 µs CMC 2,0·10⁻¹⁰ 15 mV do 250 mV od 1 µs do 10 µs CMC 2,0·10⁻⁹ 250 mV do 50 V od 1 µs do 10 µs CMC 2,0·10⁻¹⁰ 15 mV do 250 mV od 10 µs do 10 s CMC 2,0·10⁻⁴·T 250 mV do 50 V od 10 µs do 10 s CMC 2,0·10⁻⁵·T Perioda / Signalove generatory, citace, multimetry, signalove analyzatory, vibrometry, kalibracni systemy, kontrolery vibracnich testovacich systemu Kalibrace – veliciny casu a frekvence Prime mereni nebo porovnani s etalonovym citacem 15 mV az 50 V 100 ns az 1 µs CMC 2,0·10⁻¹⁰ 15 mV az 250 mV 1 µs az 10 µs CMC 2,0·10⁻⁹ 250 mV az 50 V 1 µs az 10 µs CMC 2,0·10⁻¹⁰ 15 mV az 250 mV 10 µs az 10 s CMC 2,0·10⁻⁴·T 250 mV az 50 V 10 µs az 10 s CMC 2,0·10⁻⁵·T KP-03","search_en":"Period / Signal generators, counters, multimeters, signal analyzers, vibration meters, calibration systems, vibration test system controllers Calibration – time and frequency quantities Direct measurement or comparison with a reference counter 15 mV to 50 V 100 ns to 1 µs CMC 2,0·10⁻¹⁰ 15 mV to 250 mV 1 µs to 10 µs CMC 2,0·10⁻⁹ 250 mV to 50 V 1 µs to 10 µs CMC 2,0·10⁻¹⁰ 15 mV to 250 mV 10 µs to 10 s CMC 2,0·10⁻⁴·T 250 mV to 50 V 10 µs to 10 s CMC 2,0·10⁻⁵·T KP-03","search_zh":"周期 / 信号发生器、计数器、万用表、信号分析仪、测振仪、校准系统、振动试验系统控制器 校准 – 时间和频率量 直接测量或与标准计数器比较 15 mV 至 50 V 100 ns 至 1 µs CMC 2,0·10⁻¹⁰ 15 mV 至 250 mV 1 µs 至 10 µs CMC 2,0·10⁻⁹ 250 mV 至 50 V 1 µs 至 10 µs CMC 2,0·10⁻¹⁰ 15 mV 至 250 mV 10 µs 至 10 s CMC 2,0·10⁻⁴·T 250 mV 至 50 V 10 µs 至 10 s CMC 2,0·10⁻⁵·T KP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"02fb1377b22fa2e5e0c582e1","lab_id":"6ade8b4bff06824761708138","country":"CZ","accr_number":"2395","accr_body":"ČIA","row_label":"3","test_object":"Przedział czasu / Generatory sygnałów, czasomierze, liczniki, multimetry, analizatory sygnałów","test_object_en":"Time interval / Signal generators, timers, counters, multimeters, signal analyzers","test_object_zh":"时间间隔 / 信号发生器、定时器、计数器、万用表、信号分析仪","test_object_cs":"Časový interval / Signálové generátory, časovače, čítače, multimetry, signálové analyzátory","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"250 mV do 50 V","range":"od 0,1 ms do 1000 s","cmc":"5,0·10⁻⁵"}],"parameters_en":[{"name":"250 mV to 50 V","range":"0,1 ms to 1000 s","cmc":"5,0·10⁻⁵"}],"parameters_zh":[{"name":"250 mV 至 50 V","range":"0,1 ms 至 1000 s","cmc":"5,0·10⁻⁵"}],"parameters_cs":[{"name":"250 mV až 50 V","range":"0,1 ms až 1000 s","cmc":"5,0·10⁻⁵"}],"technique":"Pomiar bezpośredni lub porównanie z licznikiem wzorcowym","technique_en":"Direct measurement or comparison with a reference counter","technique_zh":"直接测量或与标准计数器比较","technique_cs":"Přímé měření nebo porovnání s etalonovým čítačem","techniques":["Pomiar bezpośredni lub porównanie z licznikiem wzorcowym"],"techniques_en":["Direct measurement or comparison with a reference counter"],"techniques_zh":["直接测量或与标准计数器比较"],"techniques_cs":["Přímé měření nebo porovnání s etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\n250 mV do 50 V od 0,1 ms do 1000 s CMC 5,0·10⁻⁵\nPomiar bezpośredni lub porównanie z licznikiem wzorcowym","reference":"KP-03","norm_bases":["KP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / Generatory sygnałów, czasomierze, liczniki, multimetry, analizatory sygnałów Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni lub porównanie z licznikiem wzorcowym 250 mV do 50 V od 0,1 ms do 1000 s CMC 5,0·10⁻⁵ Časový interval / Signálové generátory, časovače, čítače, multimetry, signálové analyzátory Kalibrace – veličiny času a frekvence Přímé měření nebo porovnání s etalonovým čítačem 250 mV až 50 V 0,1 ms až 1000 s CMC 5,0·10⁻⁵ KP-03 Przedzial czasu / Generatory sygnalow, czasomierze, liczniki, multimetry, analizatory sygnalow Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni lub porownanie z licznikiem wzorcowym 250 mV do 50 V od 0,1 ms do 1000 s CMC 5,0·10⁻⁵ Casovy interval / Signalove generatory, casovace, citace, multimetry, signalove analyzatory Kalibrace – veliciny casu a frekvence Prime mereni nebo porovnani s etalonovym citacem 250 mV az 50 V 0,1 ms az 1000 s CMC 5,0·10⁻⁵ KP-03","search_en":"Time interval / Signal generators, timers, counters, multimeters, signal analyzers Calibration – time and frequency quantities Direct measurement or comparison with a reference counter 250 mV to 50 V 0,1 ms to 1000 s CMC 5,0·10⁻⁵ KP-03","search_zh":"时间间隔 / 信号发生器、定时器、计数器、万用表、信号分析仪 校准 – 时间和频率量 直接测量或与标准计数器比较 250 mV 至 50 V 0,1 ms 至 1000 s CMC 5,0·10⁻⁵ KP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}