🇨🇿 KZB-Kalibrace s.r.o. PL

ČIA 2374 • Most, Czech Republic • 95 calibration items

Metrology & calibration

KZB-Kalibrace s.r.o. is a calibration laboratory accredited by ČIA under number 2374 (Most, Czech Republic). Its accreditation scope covers 95 calibration items in the following areas: Metrology & calibration. Calibrated items include: Measuring jigs and profile gauges, DC resistance / DC resistance meters, Direct current / Direct current meters, Direct current / Direct current sources. Most frequently used calibration principles: Measurement on a length gauge, Measurement using parallel gauge blocks, Comparison with a reference track.

At a glance

  • Accreditation number: ČIA 2374
  • Calibration items in scope: 95
  • Types of calibrated items: 67
  • Calibration principles used: 43
  • City: Most, Czech Republic
  • Valid until: 04-11-2030
Accreditation number
2374
Accreditation body
ČIA
Address
Mikoláše Alše 2240/14, 434 01 Most
City
Most, Czech Republic
Division
Laboratorium wzorcujące
Valid until
04-11-2030

What this laboratory calibrates (67)

Calibration principles (43)

Certificate information

Certificate date
16.04.2026

Accreditation scope — calibration items (95)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Parallel gauge blocks Calibration – length
0,5 mm to 100 mm · CMC (0,8·L+ 0,14) µm
CMC for the field of measured quantity: Length
Comparison with parallel gauge blocks in vertical position on a comparator Kp 01-013
2 Parallel gauge blocks Calibration – length
100 mm to 500 mm · CMC (1·L+ 0,16) µm 1000 mm · CMC 1,2 µm
CMC for the field of measured quantity: Length
Comparison with parallel gauge blocks in horizontal position on a length gauge Kp 01-013
3 Slide gauges / slide rules, depth gauges, height gauges, gear tooth calipers Calibration – length
0 mm to 1000 mm · CMC 14 µm 1000 mm to 2000 mm · CMC 17 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks Kp 01-001
4 Linear height gauges Calibration – length
0 mm to 1000 mm · CMC (1,2·L+ 0,5) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks Kp 01-001
5 Micrometer gauges / micrometers, pasameters, micropasameters, micrometer depth gauges Calibration – length
0 mm to 25 mm · CMC 0,7 µm 25 mm to 100 mm · CMC 1,4 µm 100 mm to 1000 mm · CMC 2,2 µm 1000 mm to 1500 mm · CMC 3,8 µm 1500 mm to 2000 mm · CMC 4,4 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks Kp 01-002
6 Two-contact and three-contact internal gauges Calibration – length
3 mm to 100 mm · CMC 1,6 µm 100 mm to 250 mm · CMC 2,3 µm
CMC for the field of measured quantity: Length
Measurement by setting rings Kp 01-002
7 Inside micrometer gauges Calibration – length
10 mm to 1500 mm · CMC 3,7 µm
CMC for the field of measured quantity: Length
Comparison with parallel gauge blocks Kp 01-002
8 Micrometer gauges / inside micrometer gauges Calibration – length
10 mm to 500 mm · CMC 1 µm 500 mm to 2800 mm · CMC (3,5·L+ 0,6) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-002
9 Micrometric heads Calibration – length
0 mm to 100 mm · CMC 1 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-002
10 Setting gauges for micrometer gauges Calibration – length
0 mm to 500 mm · CMC 1 µm 500 mm to 2800 mm · CMC (3,5·L+ 0,6) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-002
11 Indicators / direct, lever indicators and internal gauges with indicator Calibration – length
0 mm to 100 mm · CMC 0,5 µm
CMC for the field of measured quantity: Length
Measurement on a dial indicator calibration instrument Kp 01-003
12 Indicators / direct, lever indicators and internal gauges with indicator Calibration – length
0 mm to 50 mm · CMC 2,9 µm
CMC for the field of measured quantity: Length
Measurement on a dial indicator calibration instrument Kp 01-003
13 Linear sensors Calibration – length
0 mm to 100 mm · CMC 0,5 µm
CMC for the field of measured quantity: Length
Measurement on a dial indicator calibration instrument Kp 01-003
14 Rules / precise gauges and measuring magnifiers Calibration – length
0 mm to 100 mm · CMC 0,5 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-004
15 Rules / precise gauges and measuring magnifiers Calibration – length
0 mm to 200 mm · CMC (5·L+ 0,65) µm 200 mm to 1000 mm · CMC (2,7·L+ 1,2) µm
CMC for the field of measured quantity: Length
Measurement on a microscope Kp 01-004
16 Steel rules Calibration – length
0 mm to 1000 mm · CMC 39 µm 1000 mm to 2000 mm · CMC 56 µm 2000 mm to 3000 mm · CMC 68 µm
CMC for the field of measured quantity: Length
Comparison with a reference steel ruler Kp 01-004
17 Tape measures Calibration – length
0 m to 10 m · CMC (0,3·L+ 0,035) mm
CMC for the field of measured quantity: Length
Comparison with a reference track Kp 01-004
18 Tape measures, wooden rulers and rulers of 2m length Calibration – length
0 m to 300 m · CMC (0,03·L+ 0,3) mm
CMC for the field of measured quantity: Length
Comparison with a reference track Kp 01-004
19 Rules / steel gauges Calibration – length
0 mm to 500 mm · CMC 0,12 mm
CMC for the field of measured quantity: Length
Comparison with parallel gauge blocks Kp 01-004, Kp 01-015
20 Tape measures Calibration – length
0 m to 10 m · CMC (0,07·L+ 0,19) mm
CMC for the field of measured quantity: Length
Comparison with a reference steel ruler Kp 01-004
21 Setting rings and snap gauges Calibration – length
0,95 mm to 10 mm · CMC 1 µm 10 mm to 330 mm · CMC (4,3·L+ 0,7) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-005
22 Cylindrical gauges Calibration – length
0 mm to 100 mm · CMC 0,5 µm 100 mm to 500 mm · CMC 1 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-005
23 Slot gauges Calibration – length
0 mm to 100 mm · CMC 0,5 µm 100 mm to 500 mm · CMC 1 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-005
24 Feeler gauges and wedges Calibration – length
0 mm to 100 mm · CMC 0,5 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-005
25 Cylindrical gauges and measuring wires Calibration – length
0 mm to 100 mm · CMC 0,5 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-005
26 Setting gauges for layer thickness gauges Calibration – length
0 mm to 100 mm · CMC 1 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-005
27 Thread gauges – plug gauges Calibration – length
0 mm to 300 mm · CMC 3,1 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-005
28 Thread gauges - female Calibration – length
2 mm to 200 mm · CMC 4 µm
CMC for the field of measured quantity: Length
Measurement on a microscope Kp 01-005
29 Thread gauges - conical Calibration – length
0 mm to 100 mm · CMC 5 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-005
30 Efflux viscometers - diameter Calibration – length
0 mm to 10 mm · CMC 4 µm
CMC for the field of measured quantity: Length
Measurement on a microscope Kp 01-005
31 Cylindrical gauges Calibration – length
0 mm to 100 mm · CMC 2 µm 0 mm to 30 mm · CMC 1,5 µm
CMC for the field of measured quantity: Length
Measurement using a micrometer Kp 01-005
32 Slot gauges Calibration – length
0 mm to 100 mm · CMC 2 µm
CMC for the field of measured quantity: Length
Measurement using a micrometer Kp 01-005
33 Feeler gauges and wedges Calibration – length
0 mm to 30 mm · CMC 1,5 µm
CMC for the field of measured quantity: Length
Measurement using a micrometer Kp 01-005
34 Thread gauges – plug gauges Calibration – length
0 mm to 100 mm · CMC 5 µm
CMC for the field of measured quantity: Length
Measurement using a micrometer Kp 01-005
35 Thickness gauges and callipers Calibration – length
external measurement — 0 mm to 500 mm · CMC 2,2 µm internal measurement — 3 mm to 500 mm · CMC 3,7 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks Kp 01-010
36 Dry layer thickness gauges Calibration – length
dry layers — 0 mm to 40 mm · CMC 1,4 µm
CMC for the field of measured quantity: Length
Measurement using a thickness reference standard Kp 01-009
37 Wet layer thickness gauges Calibration – length
wet layers — 0 mm to 15 mm · CMC 1 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-009
38 Surface plates / flatness Calibration – length
length up to 500 mm — 0 mm to 5 mm · CMC 3,5 µm length up to 1,000 mm — 0 mm to 5 mm · CMC 6,6 µm length up to 2,000 mm — 0 mm to 5 mm · CMC 35 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks Kp 01-008
39 Surface rules / straightness Calibration – length
length up to 1,000 mm — 0 mm to 5 mm · CMC 5,1 µm length up to 2,000 mm — 0 mm to 5 mm · CMC 9,5 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks Kp 01-008
40 Blade rules / straightness Calibration – length
length up to 100 mm — 0 mm to 5 mm · CMC 2,4 µm length up to 500 mm — 0 mm to 5 mm · CMC 2,8 µm length up to 1,000 mm — 0 mm to 5 mm · CMC 5,1 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks Kp 01-008
41 Roller length gauges Calibration – length
0 m to 300 m · CMC (0,2·L+ 10) mm
CMC for the field of measured quantity: Length
Measurement using special measuring equipment Kp 01-014
42 Laser distance meters Calibration – length
0,5 m to 8 m · CMC 0,3 mm
CMC for the field of measured quantity: Length
Comparison with a reference track Kp 01-014
43 Levelling rods Calibration – length
0 m to 7 m · CMC 0,3 mm
CMC for the field of measured quantity: Length
Comparison with a reference track Kp 01-014
44 Telescopic length gauges Calibration – length
0 m to 7 m · CMC 0,3 mm
CMC for the field of measured quantity: Length
Comparison with a reference track Kp 01-014
45 Weld gauges / weld parameters Calibration – length
0 mm to 20 mm · CMC 10 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks Kp 01-015
46 90° angles / perpendicularity Calibration – length
longer side up to 100 mm — 0 mm to 5 mm · CMC 2,8 µm longer side up to 1,000 mm — 0 mm to 5 mm · CMC (8·L+ 6,5) µm
CMC for the field of measured quantity: Length
Measurement using a measuring cylinder of squareness and parallel gauge blocks Kp 02-001
47 90° angles / straightness Calibration – length
longer side up to 100 mm — 0 mm to 5 mm · CMC 2,2 µm longer side up to 1,000 mm — 0 mm to 5 mm · CMC 5,1 µm
CMC for the field of measured quantity: Length
Measurement using a measuring cylinder of squareness and parallel gauge blocks Kp 02-001
48 90° angles / parallelity Calibration – length
0 mm to 5 mm · CMC 2,9 µm
CMC for the field of measured quantity: Length
Measurement using a measuring cylinder of squareness and parallel gauge blocks Kp 02-001
49 Measuring jigs and profile gauges Calibration – length
0 mm to 100 mm · CMC 0,5 µm 100 mm to 500 mm · CMC 1 µm 950 mm to 2800 mm · CMC (3,5·L+ 0,6) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge Kp 01-017
50 Measuring jigs and profile gauges Calibration – length
500 mm to 950 mm · CMC 2 µm
CMC for the field of measured quantity: Length
Measurement on a linear height gauge Kp 01-017
51 Measuring jigs and profile gauges Calibration – length
0 mm to 100 mm · CMC 2 µm
CMC for the field of measured quantity: Length
Measurement using a micrometer Kp 01-017
52 Measuring jigs and profile gauges Calibration – length
100 mm to 300 mm · CMC 12 µm
CMC for the field of measured quantity: Length
Measurement with a slide gauge Kp 01-017
53 Measuring jigs and profile gauges Calibration – length
300 mm to 2000 mm · CMC 15 µm
CMC for the field of measured quantity: Length
Comparison with parallel gauge blocks Kp 01-017
54 Measuring jigs and profile gauges Calibration – length
2 m to 10 m · CMC 0,5 mm
CMC for the field of measured quantity: Length
Measurement by a reference tape measure Kp 01-017
55 Length gauges Calibration – length
0 mm to 1000 mm · CMC (1·L+ 0,14) µm 1000 mm to 2800 mm · CMC (2·L+ 0,17) µm
CMC for the field of measured quantity: Length
Comparison with parallel gauge blocks Kp 01-011
56 Measuring microscopes, profile projectors and coordinate measuring machines Calibration – length
0 mm to 500 mm · CMC (1·L+ 0,14) µm 500 mm to 2800 mm · CMC (2,2·L+ 0,17) µm
CMC for the field of measured quantity: Length
Comparison with parallel gauge blocks Kp 01-019
57 Angle gauges Calibration – plane angle
0° to 360° · CMC 1,2´
CMC for the field of measured quantity: Plane angle
Measurement using angle gauges Kp 02-002, Kp 01-015
58 Measuring jigs and profile gauges Calibration – plane angle
0° to 360° · CMC 0,5´
CMC for the field of measured quantity: Plane angle
Measurement on a microscope Kp 01-017, Kp 01-015
59 Measuring microscopes, profile projectors and coordinate measuring machines Calibration – plane angle
0° to 360° · CMC 0,3´
CMC for the field of measured quantity: Plane angle
Comparison with angle gauges Kp 01-019
60 Torque / Torque measuring devices, torque wrenches and screwdrivers, pneumatic and electric nutrunners Calibration – force
0,15 Nm to 2 Nm · CMC 0,97 % 2 Nm to 10 Nm · CMC 0,56 % 10 Nm to 100 Nm · CMC 0,63 % 100 Nm to 1000 Nm · CMC 0,78 % 1000 Nm to 2000 Nm · CMC 0,65 %
CMC for the field of measured quantity: Force
Comparison with a reference torque sensor Kp 03-001
61 Force / Force meters and force measuring devices Calibration – force
Tension and compression — 0,5 N to 500 N · CMC 0,24 %
CMC for the field of measured quantity: Force
Comparison with reference loading weights Kp 03-002
62 Deformation and digital pressure gauges, pressure transducers, pressure measuring chains Calibration – pressure
positive gauge pressure; gas — -90 kPa to 100 kPa · CMC 0,12 kPa positive gauge pressure; gas — 0,1 MPa to 2 MPa · CMC 1,2 kPa positive gauge pressure; liquid — 0 MPa to 2 MPa · CMC 1,2 kPa positive gauge pressure; liquid — 2 MPa to 10 MPa · CMC 6,0 kPa positive gauge pressure; liquid — 10 MPa to 100 MPa · CMC 59 kPa Absolute pressure; gas — 30 kPa to 170 kPa · CMC 0,29 kPa Absolute pressure; gas — 0,17 MPa to 2,1 MPa · CMC 1,3 kPa Absolute pressure; liquid — 0,1 MPa to 2,1 MPa · CMC 1,3 kPa Absolute pressure; liquid — 2,1 MPa to 10 MPa · CMC 6,1 kPa Absolute pressure; liquid — 10 MPa to 100 MPa · CMC 59 kPa Barometric pressure — 70 kPa to 110 kPa · CMC 0,26 kPa
CMC for the field of measured quantity: Pressure
Comparison with a reference pressure gauge Kp 05-001
63 Indicating thermometers and temperature measuring chains Calibration – temperature
-20 °C to -5 °C · CMC 0,34 °C -5 °C to 50 °C · CMC 0,27 °C 50 °C to 100 °C · CMC 0,48 °C 100 °C to 650 °C · CMC 0,64 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference thermometer in a dry block Kp 07-001
64 Indicating thermometers and temperature measuring chains Calibration – temperature
-5 °C to 40 °C · CMC 0,90 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference thermometer in a climatic chamber Kp 07-001
65 Non-contact thermometers Calibration – temperature
30 °C to 100 °C · CMC 1,7 °C 100 °C to 200 °C · CMC 2,6 °C 200 °C to 300 °C · CMC 2,7 °C 300 °C to 400 °C · CMC 3,0 °C 400 °C to 500 °C · CMC 3,3 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference target black body Kp 07-002
66 Simulation of temperature sensor signals / temperature sensor processing units Calibration – temperature
J — -210 °C to -100 °C · CMC 0,57 °C J — -100 °C to 150 °C · CMC 0,33 °C J — 150 °C to 760 °C · CMC 0,38 °C J — 760 °C to 1200 °C · CMC 0,48 °C K — -200 °C to -100 °C · CMC 0,66 °C K — -100 °C to 120 °C · CMC 0,40 °C K — 120 °C to 1370 °C · CMC 0,63 °C T — -250 °C to -150 °C · CMC 1,5 °C T — -150 °C to 400 °C · CMC 0,37 °C R — 0 °C to 250 °C · CMC 1,9 °C R — 250 °C to 1760 °C · CMC 1,2 °C S — 0 °C to 250 °C · CMC 1,9 °C S — 250 °C to 1760 °C · CMC 1,2 °C B — 600 °C to 1820 °C · CMC 1,8 °C N — -200 °C to -100 °C · CMC 1,0 °C N — -100 °C to 410 °C · CMC 0,51 °C N — 410 °C to 1300 °C · CMC 0,59 °C E — -250 °C to -100 °C · CMC 1,3 °C E — -100 °C to 650 °C · CMC 0,47 °C E — 650 °C to 1000 °C · CMC 0,51 °C L — -200 °C to 900 °C · CMC 0,81 °C U — -200 °C to 600 °C · CMC 0,95 °C C — 0 °C to 1000 °C · CMC 0,72 °C C — 1000 °C to 2310 °C · CMC 1,7 °C
CMC for the field of measured quantity: Temperature
Reference voltage calibrator simulation including cold junction compensation Kp 04-001
67 Simulation of temperature sensor signals / temperature sensor processing units Calibration – temperature
RTD — -200 °C to 0 °C · CMC 0,35 °C RTD — 0 °C to 800 °C · CMC 0,58 °C
CMC for the field of measured quantity: Temperature
Reference resistance calibrator simulation Kp 04-001
68 Direct-current voltage / DC voltage sources Calibration – electrical quantities
0 mV to 100 mV · CMC 0,0037 % + 13 µV 0,1 V to 1 V · CMC 0,0025 % + 37 µV 1 V to 10 V · CMC 0,0024 % + 0,36 mV 10 V to 100 V · CMC 0,0038 % + 3,6 mV 100 V to 1000 V · CMC 0,0041 % + 36 mV
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a reference multimeter Kp 04-001, Kp 04-003
69 Direct-current voltage / DC voltage sources Calibration – electrical quantities
1 kV to 3 kV · CMC 0,5 % + 0,037 kV 3 kV to 10 kV · CMC 0,5 % + 0,049 kV
CMC for the field of measured quantity: Electrical quantities
Indirect measurement with a reference calibrator with a Hipot adapter Kp 04-001, Kp 04-003
70 Direct-current voltage / DC voltage meters Calibration – electrical quantities
0 mV to 100 mV · CMC 0,008 % + 12 µV 0,1 V to 1 V · CMC 0,008 % + 35 µV 1 V to 10 V · CMC 0,008 % + 0,35 mV 10 V to 100 V · CMC 0,008 % + 3,5 mV 100 V to 1000 V · CMC 0,008 % + 35 mV
CMC for the field of measured quantity: Electrical quantities
Direct generation with a reference calibrator Kp 04-001, Kp 04-003
71 Direct current / Direct current sources Calibration – electrical quantities
0 µA to 100 µA · CMC 0,05 % + 37 nA 0,1 mA to 1 mA · CMC 0,05 % + 0,12 µA 1 mA to 10 mA · CMC 0,05 % + 2,5 µA 10 mA to 100 mA · CMC 0,05 % + 14 µA 100 mA to 400 mA · CMC 0,05 % + 73 µA 0,4 A to 1 A · CMC 0,05 % + 0,3 mA 1 A to 3 A · CMC 0,10 % + 0,8 mA 3 A to 10 A · CMC 0,15 % + 1,6 mA
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a reference multimeter Kp 04-001, Kp 04-003
72 Direct current / Direct current sources Calibration – electrical quantities
0 A to 40 A · CMC 2,8 % + 0,52 A 40 A to 400 A · CMC 2,8 % + 2,8 A
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a reference clamp multimeter Kp 04-001, Kp 04-003
73 Direct current / Direct current sources Calibration – electrical quantities
10 A to 100 A · CMC 0,2 % + 0,013 A 100 A to 200 A · CMC 0,2 % + 0,035 A
CMC for the field of measured quantity: Electrical quantities
Indirect measurement using a reference shunt and multimeter Kp 04-001, Kp 04-003
74 Direct current / Direct current meters Calibration – electrical quantities
0 µA to 100 µA · CMC 0,03 % + 35 nA 0,1 mA to 1 mA · CMC 0,03 % + 0,12 µA 1 mA to 10 mA · CMC 0,03 % + 1,2 µA 10 mA to 100 mA · CMC 0,03 % + 12 µA 0,1 A to 1 A · CMC 0,03 % + 0,18 mA 1 A to 10 A · CMC 0,05 % + 2,4 mA
CMC for the field of measured quantity: Electrical quantities
Direct generation with a reference calibrator Kp 04-001, Kp 04-003
75 Direct current / Direct current meters Calibration – electrical quantities
10 A to 50 A · CMC 0,2 %+ 0,013 A
CMC for the field of measured quantity: Electrical quantities
Indirect comparison with a reference shunt and multimeter Kp 04-001, Kp 04-003
76 Direct current / Direct current meters Calibration – electrical quantities
0 A to 20 A · CMC 0,56 % + 0,13 A 20 A to 100 A · CMC 0,65 % + 0,17 A 100 A to 500 A · CMC 0,53 % + 0,52 A
CMC for the field of measured quantity: Electrical quantities
Reference current simulation with a calibrator and current coil Kp 04-001, Kp 04-003
77 Alternating-current voltage / AC voltage sources Calibration – electrical quantities
10 Hz to 20 kHz — 0,1 mV to 100 mV · CMC 0,06 % + 51 µV 10 Hz to 20 kHz — 0,1 V to 1 V · CMC 0,06 % + 0,36 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 0,06 % + 3,6 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 0,06 % + 37 mV 10 Hz to 20 kHz — 100 V to 1000 V · CMC 0,06 % + 0,29 V
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a reference multimeter Kp 04-001, Kp 04-003
78 Alternating-current voltage / AC voltage sources Calibration – electrical quantities
50 Hz to 60 Hz — 1 kV to 3 kV · CMC 0,5 % + 0,039 kV 50 Hz to 60 Hz — 3 kV to 10 kV · CMC 0,5 % + 0,11 kV
CMC for the field of measured quantity: Electrical quantities
Indirect measurement with a reference calibrator with a Hipot adapter Kp 04-001, Kp 04-003
79 Alternating-current voltage / AC voltage meters Calibration – electrical quantities
10 Hz to 2 kHz — 0,1 mV to 100 mV · CMC 0,08 % + 43 µV 10 Hz to 2 kHz — 0,1 V to 1 V · CMC 0,08 % + 0,39 mV 10 Hz to 2 kHz — 1 V to 10 V · CMC 0,08 % + 4,0 mV 40 Hz to 1 kHz — 10 V to 100 V · CMC 0,08 % + 43 mV 40 Hz to 1 kHz — 100 V to 1000 V · CMC 0,08 % + 0,60 mV
CMC for the field of measured quantity: Electrical quantities
Direct generation with a reference calibrator Kp 04-001, Kp 04-003
80 Alternating current / Alternating current sources Calibration – electrical quantities
10 Hz to 2 kHz — 0,1 µA to 100 µA · CMC 0,15 % + 80 nA 10 Hz to 2 kHz — 0,1 mA to 1 mA · CMC 0,10 % + 0,54 µA 10 Hz to 2 kHz — 1 mA to 10 mA · CMC 0,15 % + 7,5 µA 10 Hz to 2 kHz — 10 mA to 100 mA · CMC 0,10 % + 56 µA 10 Hz to 1 kHz — 100 mA to 400 mA · CMC 0,10 % + 0,51 mA 10 Hz to 2 kHz — 0,4 A to 1 A · CMC 0,10 % + 0,8 mA 10 Hz to 2 kHz — 1 A to 3 A · CMC 0,15 % + 2,4 mA 10 Hz to 2 kHz — 3 A to 10 A · CMC 0,15 % + 16 mA
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a reference multimeter Kp 04-001, Kp 04-003
81 Alternating current / Alternating current sources Calibration – electrical quantities
30 Hz to 60 Hz — 0 A to 40 A · CMC 2,0 % + 0,46 A 30 Hz to 60 Hz — 40 A to 400 A · CMC 2,8 % + 2,9 A
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a reference clamp multimeter Kp 04-001, Kp 04-003
82 Alternating current / Alternating current meters Calibration – electrical quantities
10 Hz to 2 kHz — 0,1 µA to 100 µA · CMC 0,1 % + 0,47 µA 10 Hz to 2 kHz — 0,1 mA to 1 mA · CMC 0,1 % + 0,96 µA 10 Hz to 2 kHz — 1 mA to 10 mA · CMC 0,1 % + 9,5 µA 10 Hz to 2 kHz — 10 mA to 100 mA · CMC 0,1 % + 96 µA 10 Hz to 2 kHz — 0,1 A to 1 A · CMC 0,1 % + 0,95 mA 10 Hz to 2 kHz — 1 A to 10 A · CMC 0,1 % + 20 mA
CMC for the field of measured quantity: Electrical quantities
Direct generation with a reference calibrator Kp 04-001, Kp 04-003
83 Alternating current / Alternating current meters Calibration – electrical quantities
30 Hz to 60 Hz — 0 A to 20 A · CMC 0,56 % + 0,12 A 30 Hz to 60 Hz — 20 A to 100 A · CMC 0,65 % + 0,17 A 30 Hz to 60 Hz — 100 A to 500 A · CMC 0,53 % + 0,53 A
CMC for the field of measured quantity: Electrical quantities
Reference current simulation with a calibrator and current coil Kp 04-001, Kp 04-003
84 DC resistance / resistors and resistance boxes Calibration – electrical quantities
0 Ω to 10 Ω · CMC 0,01 % + 12 mΩ 10 Ω to 100 Ω · CMC 0,01 % + 58 mΩ 100 Ω to 1000 Ω · CMC 0,01 % + 59 mΩ 1 kΩ to 10 kΩ · CMC 0,01 % + 0,17 Ω 10 kΩ to 100 kΩ · CMC 0,01 % + 2,1 Ω 100 kΩ to 1000 kΩ · CMC 0,01 % + 32 Ω 1 MΩ to 10 MΩ · CMC 0,04 % + 1,3 kΩ 10 MΩ to 100 MΩ · CMC 0,8 % + 35 kΩ 100 MΩ to 1000 MΩ · CMC 2,0 % + 0,21 MΩ
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a reference multimeter Kp 04-001, Kp 04-002
85 DC resistance / resistors and resistance boxes Calibration – electrical quantities
0,01 Ω to 0,1 Ω · CMC 65µΩ 0,1 Ω to 1 Ω · CMC 0,052 % 1 Ω to 10 Ω · CMC 0,14 %
CMC for the field of measured quantity: Electrical quantities
Indirect measurement – volt – ampere method Kp 04-002
86 DC resistance / DC resistance meters Calibration – electrical quantities
1 mΩ · CMC 2,4 µΩ 10 mΩ · CMC 24 µΩ 0,01 Ω to 0,1 Ω · CMC 2 % + 0,10 mΩ 0,1 Ω to 1 Ω · CMC 0,2 % + 0,54 mΩ
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a reference resistance box or resistance standards Kp 04-001, Kp 04-003
87 DC resistance / DC resistance meters Calibration – electrical quantities
1 Ω to 10 Ω · CMC 20 mΩ 10 Ω to 100 Ω · CMC 40 mΩ 100 Ω to 1 kΩ · CMC 0,27 Ω 1 kΩ to 10 kΩ · CMC 2,4 Ω 10 kΩ to 100 kΩ · CMC 24 Ω 0,1 MΩ to 1 MΩ · CMC 0,24 kΩ 1 MΩ to 10 MΩ · CMC 5,8 kΩ 100 MΩ to 2000 MΩ · CMC 1,3 % + 5,8 kΩ
CMC for the field of measured quantity: Electrical quantities
Direct generation with a reference calibrator Kp 04-001, Kp 04-003
88 DC resistance / DC resistance meters Calibration – electrical quantities
0,1 MΩ to 0,5 MΩ · CMC 0,05 % + 10 Ω 0,6 MΩ to 0,9 MΩ · CMC 0,05 % + 15 Ω 1 MΩ to 5 MΩ · CMC 0,05 % + 0,25 kΩ 6 MΩ to 9 MΩ · CMC 0,05 % + 0,35 kΩ 10 MΩ to 50 MΩ · CMC 0,1 % + 2,5 kΩ 50 MΩ to 100 MΩ · CMC 0,1 % + 9 kΩ
CMC for the field of measured quantity: Electrical quantities
Direct generation using a reference resistance box Kp 04-001, Kp 04-003
89 Transition resistance / Inspection instruments Calibration – electrical quantities
1 mΩ · CMC 2,4 µΩ 10 mΩ · CMC 24 µΩ 0,01 Ω to 0,09 Ω · CMC 2 % + 0,10 mΩ 0,1 Ω to 1 Ω · CMC 0,2 % + 0,54 mΩ 1 Ω to 10 Ω · CMC 0,1 % + 14 mΩ 10 Ω to 100 Ω · CMC 0,05 % + 70 mΩ 100 Ω to 1000 Ω · CMC 0,05 % + 180 mΩ 1 kΩ to 10 kΩ · CMC 0,05 % + 1,4 Ω
CMC for the field of measured quantity: Electrical quantities
Direct generation by a reference resistance box or resistance standards Kp 04-003
90 Insulation resistance / Inspection instruments Calibration – electrical quantities
Measuring voltage up to 100 V — 10 kΩ to 100 kΩ · CMC 0,05 % + 14 Ω Measuring voltage up to 100 V — 0,1 MΩ to 0,5 MΩ · CMC 0,05 % + 10 Ω Measuring voltage up to 100 V — 0,6 MΩ to 0,9 MΩ · CMC 0,05 % + 15 Ω Measuring voltage up to 500 V — 1 MΩ to 5 MΩ · CMC 0,05 % + 0,25 kΩ Measuring voltage up to 500 V — 6 MΩ to 9 MΩ · CMC 0,05 % + 0,35 kΩ Measuring voltage up to 1,000 V — 10 MΩ to 50 MΩ · CMC 0,1 % + 2,5 kΩ Measuring voltage up to 1,000 V — 50 MΩ to 100 MΩ · CMC 0,1 % + 9,0 kΩ Measuring voltage up to 5,000 V — 100 MΩ to 1000 MΩ · CMC 1,2 % Measuring voltage up to 5,000 V — 1 GΩ to 10 GΩ · CMC 1,2 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a reference resistance box Kp 04-003
91 Leakage current / Inspection instruments Calibration – electrical quantities
50 Hz to 60 Hz — 0,1 mA to 1 mA · CMC 0,10 % + 0,54 µA 50 Hz to 60 Hz — 1 mA to 10 mA · CMC 0,15 % + 7,5 µA 50 Hz to 60 Hz — 10 mA to 100 mA · CMC 0,10 % + 56 µA
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a reference ammeter Kp 04-003
92 Impedance of a protective loop, mains impedance / Inspection instruments Calibration – electrical quantities
Z₀ parameter value — 0,4 Ω to 2 Ω · CMC 32 mΩ 0,05 Ω to + Z₀ · CMC 5,1 mΩ 0,10 Ω to + Z₀ · CMC 5,5 mΩ 0,22 Ω to + Z₀ · CMC 6,1 mΩ 0,33 Ω to + Z₀ · CMC 6,8 mΩ 0,50 Ω to + Z₀ · CMC 7,6 mΩ 1,0 Ω to + Z₀ · CMC 11 mΩ 5,0 Ω to + Z₀ · CMC 34 mΩ 10 Ω to + Z₀ · CMC 57 mΩ 100 Ω to + Z₀ · CMC 0,53 Ω 1000 Ω to + Z₀ · CMC 5,2 Ω
CMC for the field of measured quantity: Electrical quantities
Direct generation of impedance with a reference calibrator Kp 04-003
93 Tripping current of residual current circuit breakers / Inspection instruments Calibration – electrical quantities
2 mA to 10 mA · CMC 1,2 % + 72 µA 10 mA to 30 mA · CMC 1,2 % + 0,11 mA 30 mA to 100 mA · CMC 1,2 % + 0,17 mA 100 mA to 300 mA · CMC 1,2 % + 0,84 mA 300 mA to 1000 mA · CMC 1,2 % + 1,7 mA 1000 mA to 3000 mA · CMC 1,2 % + 3,0 mA
CMC for the field of measured quantity: Electrical quantities
Comparison with a reference calibrator Kp 04-003
94 Tripping time of residual current circuit breakers / Inspection instruments Calibration – electrical quantities
20 ms to 900 ms · CMC 1 ms
CMC for the field of measured quantity: Electrical quantities
Comparison with a reference calibrator Kp 04-003
95 Time interval / mechanical and digital stopwatch, timers and other time meters Calibration – time and frequency quantities
5 s to 3600 s · CMC 11 ms
CMC for the field of measured quantity: Time and frequency quantities
Comparison with a reference counter Kp 06-001

Reference standards (25)

Kp 01-001
Kp 01-002
Kp 01-003
Kp 01-004
Kp 01-005
Kp 01-008
Kp 01-009
Kp 01-010
Kp 01-011
Kp 01-013
Kp 01-014
Kp 01-015
Kp 01-017
Kp 01-019
Kp 02-001
Kp 02-002
Kp 03-001
Kp 03-002
Kp 04-001
Kp 04-002
Kp 04-003
Kp 05-001
Kp 06-001
Kp 07-001
Kp 07-002

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2374