{"lab":{"_id":"6ade8b40ff06824761708128","accr_number":"2374","country":"CZ","accr_body":"ČIA","address":"Mikoláše Alše 2240/14, 434 01 Most","categories":["metrology"],"city":"Most","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[13.6397908,50.5133637]},"map_coord":[50.5133637,13.6397908],"map_geo":"cai-mapa","methods_count":95,"name":"KZB-Kalibrace s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: długość, kąt płaski, moment siły, ciśnienie, czas, temperatura i wielkości elektryczne, w zakresie określonym w załączniku do świadectwa.","search_text":"kzb-kalibrace s.r.o. mikoláše alše 2240/14, 434 01 most 2374","source_page_url":"https://www.cai.cz/?subjekt=2374-kzb-kalibrace-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"04-11-2030","website":"www.kzb-kalibrace.cz","certificate_date":"16.04.2026","certificate_no":"194/2026","certificate_replaces":"560/2025 z 04.11.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: długość, kąt płaski, moment siły, ciśnienie, czas, temperatura i wielkości elektryczne, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of gauges of length, plane angle, torque, pressure, time, temperature and electrical quantities to the extent as specified in the appendix to this Certificate.","zh":"长度、平面角、力矩、压力、时间、温度和电学量领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech délka, rovinný úhel, moment síly, tlak, čas, teplota a elektrické veličiny, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"b9e66e8bb3c1503e884a5eaca71d5960c74367d176a3b62af228708529555bd3","source_pdf_url":"https://www.cai.cz/OA/pdf/194_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/194_2026_EN.pdf"},"methods":[{"_id":"4ef001a2b1bdd5c692e3ab57","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Płytki wzorcowe","test_object_en":"Parallel gauge blocks","test_object_zh":"量块","test_object_cs":"Koncové měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,5 mm do 100 mm","cmc":"(0,8·L+ 0,14) µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 100 mm","cmc":"(0,8·L+ 0,14) µm"}],"parameters_zh":[{"name":"","range":"0,5 mm 至 100 mm","cmc":"(0,8·L+ 0,14) µm"}],"parameters_cs":[{"name":"","range":"0,5 mm až 100 mm","cmc":"(0,8·L+ 0,14) µm"}],"technique":"Porównanie z płytkami wzorcowymi w położeniu pionowym na komparatorze","technique_en":"Comparison with parallel gauge blocks in vertical position on a comparator","technique_zh":"在比较仪上以垂直位置与量块比较","technique_cs":"Porovnání s koncovými měrkami ve svislé poloze na komparačním přístroji","techniques":["Porównanie z płytkami wzorcowymi w położeniu pionowym na komparatorze"],"techniques_en":["Comparison with parallel gauge blocks in vertical position on a comparator"],"techniques_zh":["在比较仪上以垂直位置与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami ve svislé poloze na komparačním přístroji"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,5 mm do 100 mm CMC (0,8·L+ 0,14) µm\nPorównanie z płytkami wzorcowymi w położeniu pionowym na komparatorze","reference":"Kp 01-013","norm_bases":["Kp 01-013"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi w położeniu pionowym na komparatorze od 0,5 mm do 100 mm CMC (0,8·L+ 0,14) µm Koncové měrky Kalibrace – délka Porovnání s koncovými měrkami ve svislé poloze na komparačním přístroji 0,5 mm až 100 mm CMC (0,8·L+ 0,14) µm Kp 01-013 Plytki wzorcowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi w polozeniu pionowym na komparatorze od 0,5 mm do 100 mm CMC (0,8·L+ 0,14) µm Koncove merky Kalibrace – delka Porovnani s koncovymi merkami ve svisle poloze na komparacnim pristroji 0,5 mm az 100 mm CMC (0,8·L+ 0,14) µm Kp 01-013","search_en":"Parallel gauge blocks Calibration – length Comparison with parallel gauge blocks in vertical position on a comparator 0,5 mm to 100 mm CMC (0,8·L+ 0,14) µm Kp 01-013","search_zh":"量块 校准 – 长度 在比较仪上以垂直位置与量块比较 0,5 mm 至 100 mm CMC (0,8·L+ 0,14) µm Kp 01-013","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4c4a3f43dac2606dde3206f","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Płytki wzorcowe","test_object_en":"Parallel gauge blocks","test_object_zh":"量块","test_object_cs":"Koncové měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 100 mm do 500 mm","cmc":"(1·L+ 0,16) µm"},{"name":"","range":"1000 mm","cmc":"1,2 µm"}],"parameters_en":[{"name":"","range":"100 mm to 500 mm","cmc":"(1·L+ 0,16) µm"},{"name":"","range":"1000 mm","cmc":"1,2 µm"}],"parameters_zh":[{"name":"","range":"100 mm 至 500 mm","cmc":"(1·L+ 0,16) µm"},{"name":"","range":"1000 mm","cmc":"1,2 µm"}],"parameters_cs":[{"name":"","range":"100 mm až 500 mm","cmc":"(1·L+ 0,16) µm"},{"name":"","range":"1000 mm","cmc":"1,2 µm"}],"technique":"Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu","technique_en":"Comparison with parallel gauge blocks in horizontal position on a length gauge","technique_zh":"在测长仪上以水平位置与量块比较","technique_cs":"Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru","techniques":["Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu"],"techniques_en":["Comparison with parallel gauge blocks in horizontal position on a length gauge"],"techniques_zh":["在测长仪上以水平位置与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 100 mm do 500 mm CMC (1·L+ 0,16) µm\n1000 mm CMC 1,2 µm\nPorównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu","reference":"Kp 01-013","norm_bases":["Kp 01-013"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu od 100 mm do 500 mm CMC (1·L+ 0,16) µm 1000 mm CMC 1,2 µm Koncové měrky Kalibrace – délka Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru 100 mm až 500 mm CMC (1·L+ 0,16) µm 1000 mm CMC 1,2 µm Kp 01-013 Plytki wzorcowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi w polozeniu poziomym na dlugosciomierzu od 100 mm do 500 mm CMC (1·L+ 0,16) µm 1000 mm CMC 1,2 µm Koncove merky Kalibrace – delka Porovnani s koncovymi merkami ve vodorovne poloze na delkomeru 100 mm az 500 mm CMC (1·L+ 0,16) µm 1000 mm CMC 1,2 µm Kp 01-013","search_en":"Parallel gauge blocks Calibration – length Comparison with parallel gauge blocks in horizontal position on a length gauge 100 mm to 500 mm CMC (1·L+ 0,16) µm 1000 mm CMC 1,2 µm Kp 01-013","search_zh":"量块 校准 – 长度 在测长仪上以水平位置与量块比较 100 mm 至 500 mm CMC (1·L+ 0,16) µm 1000 mm CMC 1,2 µm Kp 01-013","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"091046247b536812e95c88e1","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Przyrządy suwmiarkowe/ suwmiarki, głębokościomierze, wysokościomierze, suwmiarki modułowe","test_object_en":"Slide gauges / slide rules, depth gauges, height gauges, gear tooth calipers","test_object_zh":"游标量具/ 游标卡尺、深度尺、高度尺、齿厚卡尺","test_object_cs":"Posuvná měřidla/ posuvky, hloubkoměry, výškoměry, zuboměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"14 µm"},{"name":"","range":"od 1000 mm do 2000 mm","cmc":"17 µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"14 µm"},{"name":"","range":"1000 mm to 2000 mm","cmc":"17 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"14 µm"},{"name":"","range":"1000 mm 至 2000 mm","cmc":"17 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"14 µm"},{"name":"","range":"1000 mm až 2000 mm","cmc":"17 µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"使用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["使用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 1000 mm CMC 14 µm\nod 1000 mm do 2000 mm CMC 17 µm\nPomiar za pomocą płytek wzorcowych","reference":"Kp 01-001","norm_bases":["Kp 01-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy suwmiarkowe/ suwmiarki, głębokościomierze, wysokościomierze, suwmiarki modułowe Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 0 mm do 1000 mm CMC 14 µm od 1000 mm do 2000 mm CMC 17 µm Posuvná měřidla/ posuvky, hloubkoměry, výškoměry, zuboměry Kalibrace – délka Měření pomocí koncových měrek 0 mm až 1000 mm CMC 14 µm 1000 mm až 2000 mm CMC 17 µm Kp 01-001 Przyrzady suwmiarkowe/ suwmiarki, glebokosciomierze, wysokosciomierze, suwmiarki modulowe Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 0 mm do 1000 mm CMC 14 µm od 1000 mm do 2000 mm CMC 17 µm Posuvna meridla/ posuvky, hloubkomery, vyskomery, zubomery Kalibrace – delka Mereni pomoci koncovych merek 0 mm az 1000 mm CMC 14 µm 1000 mm az 2000 mm CMC 17 µm Kp 01-001","search_en":"Slide gauges / slide rules, depth gauges, height gauges, gear tooth calipers Calibration – length Measurement using parallel gauge blocks 0 mm to 1000 mm CMC 14 µm 1000 mm to 2000 mm CMC 17 µm Kp 01-001","search_zh":"游标量具/ 游标卡尺、深度尺、高度尺、齿厚卡尺 校准 – 长度 使用量块测量 0 mm 至 1000 mm CMC 14 µm 1000 mm 至 2000 mm CMC 17 µm Kp 01-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"252239073dd918606a9b7002","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"3","test_object":"Wysokościomierze liniowe","test_object_en":"Linear height gauges","test_object_zh":"线性高度尺","test_object_cs":"Lineární výškoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"(1,2·L+ 0,5) µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"(1,2·L+ 0,5) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(1,2·L+ 0,5) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"(1,2·L+ 0,5) µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"使用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["使用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC (1,2·L+ 0,5) µm\nPomiar za pomocą płytek wzorcowych","reference":"Kp 01-001","norm_bases":["Kp 01-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wysokościomierze liniowe Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 0 mm do 1000 mm CMC (1,2·L+ 0,5) µm Lineární výškoměry Kalibrace – délka Měření pomocí koncových měrek 0 mm až 1000 mm CMC (1,2·L+ 0,5) µm Kp 01-001 Wysokosciomierze liniowe Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 0 mm do 1000 mm CMC (1,2·L+ 0,5) µm Linearni vyskomery Kalibrace – delka Mereni pomoci koncovych merek 0 mm az 1000 mm CMC (1,2·L+ 0,5) µm Kp 01-001","search_en":"Linear height gauges Calibration – length Measurement using parallel gauge blocks 0 mm to 1000 mm CMC (1,2·L+ 0,5) µm Kp 01-001","search_zh":"线性高度尺 校准 – 长度 使用量块测量 0 mm 至 1000 mm CMC (1,2·L+ 0,5) µm Kp 01-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1d9d70af2d14f7493f049cb3","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"4","test_object":"Przyrządy mikrometryczne/ mikrometry, pasametry, mikropasametry, głębokościomierze mikrometryczne","test_object_en":"Micrometer gauges / micrometers, pasameters, micropasameters, micrometer depth gauges","test_object_zh":"千分尺类量具/ 千分尺、杠杆卡规、杠杆千分尺、深度千分尺","test_object_cs":"Mikrometrická měřidla/ mikrometry, pasametry, mikropasametry, mikrometrické hloubkoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 25 mm","cmc":"0,7 µm"},{"name":"","range":"od 25 mm do 100 mm","cmc":"1,4 µm"},{"name":"","range":"od 100 mm do 1000 mm","cmc":"2,2 µm"},{"name":"","range":"od 1000 mm do 1500 mm","cmc":"3,8 µm"},{"name":"","range":"od 1500 mm do 2000 mm","cmc":"4,4 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"0,7 µm"},{"name":"","range":"25 mm to 100 mm","cmc":"1,4 µm"},{"name":"","range":"100 mm to 1000 mm","cmc":"2,2 µm"},{"name":"","range":"1000 mm to 1500 mm","cmc":"3,8 µm"},{"name":"","range":"1500 mm to 2000 mm","cmc":"4,4 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"0,7 µm"},{"name":"","range":"25 mm 至 100 mm","cmc":"1,4 µm"},{"name":"","range":"100 mm 至 1000 mm","cmc":"2,2 µm"},{"name":"","range":"1000 mm 至 1500 mm","cmc":"3,8 µm"},{"name":"","range":"1500 mm 至 2000 mm","cmc":"4,4 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 25 mm","cmc":"0,7 µm"},{"name":"","range":"25 mm až 100 mm","cmc":"1,4 µm"},{"name":"","range":"100 mm až 1000 mm","cmc":"2,2 µm"},{"name":"","range":"1000 mm až 1500 mm","cmc":"3,8 µm"},{"name":"","range":"1500 mm až 2000 mm","cmc":"4,4 µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"使用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["使用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 25 mm CMC 0,7 µm\nod 25 mm do 100 mm CMC 1,4 µm\nod 100 mm do 1000 mm CMC 2,2 µm\nod 1000 mm do 1500 mm CMC 3,8 µm\nod 1500 mm do 2000 mm CMC 4,4 µm\nPomiar za pomocą płytek wzorcowych","reference":"Kp 01-002","norm_bases":["Kp 01-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy mikrometryczne/ mikrometry, pasametry, mikropasametry, głębokościomierze mikrometryczne Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 0 mm do 25 mm CMC 0,7 µm od 25 mm do 100 mm CMC 1,4 µm od 100 mm do 1000 mm CMC 2,2 µm od 1000 mm do 1500 mm CMC 3,8 µm od 1500 mm do 2000 mm CMC 4,4 µm Mikrometrická měřidla/ mikrometry, pasametry, mikropasametry, mikrometrické hloubkoměry Kalibrace – délka Měření pomocí koncových měrek 0 mm až 25 mm CMC 0,7 µm 25 mm až 100 mm CMC 1,4 µm 100 mm až 1000 mm CMC 2,2 µm 1000 mm až 1500 mm CMC 3,8 µm 1500 mm až 2000 mm CMC 4,4 µm Kp 01-002 Przyrzady mikrometryczne/ mikrometry, pasametry, mikropasametry, glebokosciomierze mikrometryczne Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 0 mm do 25 mm CMC 0,7 µm od 25 mm do 100 mm CMC 1,4 µm od 100 mm do 1000 mm CMC 2,2 µm od 1000 mm do 1500 mm CMC 3,8 µm od 1500 mm do 2000 mm CMC 4,4 µm Mikrometricka meridla/ mikrometry, pasametry, mikropasametry, mikrometricke hloubkomery Kalibrace – delka Mereni pomoci koncovych merek 0 mm az 25 mm CMC 0,7 µm 25 mm az 100 mm CMC 1,4 µm 100 mm az 1000 mm CMC 2,2 µm 1000 mm az 1500 mm CMC 3,8 µm 1500 mm az 2000 mm CMC 4,4 µm Kp 01-002","search_en":"Micrometer gauges / micrometers, pasameters, micropasameters, micrometer depth gauges Calibration – length Measurement using parallel gauge blocks 0 mm to 25 mm CMC 0,7 µm 25 mm to 100 mm CMC 1,4 µm 100 mm to 1000 mm CMC 2,2 µm 1000 mm to 1500 mm CMC 3,8 µm 1500 mm to 2000 mm CMC 4,4 µm Kp 01-002","search_zh":"千分尺类量具/ 千分尺、杠杆卡规、杠杆千分尺、深度千分尺 校准 – 长度 使用量块测量 0 mm 至 25 mm CMC 0,7 µm 25 mm 至 100 mm CMC 1,4 µm 100 mm 至 1000 mm CMC 2,2 µm 1000 mm 至 1500 mm CMC 3,8 µm 1500 mm 至 2000 mm CMC 4,4 µm Kp 01-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"071c909c0bd7538c7a02de34","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"4","test_object":"Średnicówki dwupunktowe i trzypunktowe","test_object_en":"Two-contact and three-contact internal gauges","test_object_zh":"两点式和三点式内径表","test_object_cs":"Dvoudotekové a třídotekové dutinoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 3 mm do 100 mm","cmc":"1,6 µm"},{"name":"","range":"od 100 mm do 250 mm","cmc":"2,3 µm"}],"parameters_en":[{"name":"","range":"3 mm to 100 mm","cmc":"1,6 µm"},{"name":"","range":"100 mm to 250 mm","cmc":"2,3 µm"}],"parameters_zh":[{"name":"","range":"3 mm 至 100 mm","cmc":"1,6 µm"},{"name":"","range":"100 mm 至 250 mm","cmc":"2,3 µm"}],"parameters_cs":[{"name":"","range":"3 mm až 100 mm","cmc":"1,6 µm"},{"name":"","range":"100 mm až 250 mm","cmc":"2,3 µm"}],"technique":"Pomiar za pomocą pierścieni nastawczych","technique_en":"Measurement by setting rings","technique_zh":"使用校对环测量","technique_cs":"Měření pomocí nastavovacích kroužků","techniques":["Pomiar za pomocą pierścieni nastawczych"],"techniques_en":["Measurement by setting rings"],"techniques_zh":["使用校对环测量"],"techniques_cs":["Měření pomocí nastavovacích kroužků"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 3 mm do 100 mm CMC 1,6 µm\nod 100 mm do 250 mm CMC 2,3 µm\nPomiar za pomocą pierścieni nastawczych","reference":"Kp 01-002","norm_bases":["Kp 01-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Średnicówki dwupunktowe i trzypunktowe Wzorcowanie – długość Pomiar za pomocą pierścieni nastawczych od 3 mm do 100 mm CMC 1,6 µm od 100 mm do 250 mm CMC 2,3 µm Dvoudotekové a třídotekové dutinoměry Kalibrace – délka Měření pomocí nastavovacích kroužků 3 mm až 100 mm CMC 1,6 µm 100 mm až 250 mm CMC 2,3 µm Kp 01-002 Srednicowki dwupunktowe i trzypunktowe Wzorcowanie – dlugosc Pomiar za pomoca pierscieni nastawczych od 3 mm do 100 mm CMC 1,6 µm od 100 mm do 250 mm CMC 2,3 µm Dvoudotekove a tridotekove dutinomery Kalibrace – delka Mereni pomoci nastavovacich krouzku 3 mm az 100 mm CMC 1,6 µm 100 mm az 250 mm CMC 2,3 µm Kp 01-002","search_en":"Two-contact and three-contact internal gauges Calibration – length Measurement by setting rings 3 mm to 100 mm CMC 1,6 µm 100 mm to 250 mm CMC 2,3 µm Kp 01-002","search_zh":"两点式和三点式内径表 校准 – 长度 使用校对环测量 3 mm 至 100 mm CMC 1,6 µm 100 mm 至 250 mm CMC 2,3 µm Kp 01-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a02bedb82556ddd4aabfd4ac","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"4","test_object":"Średnicówki mikrometryczne","test_object_en":"Inside micrometer gauges","test_object_zh":"内径千分尺","test_object_cs":"Mikrometrické odpichy","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 10 mm do 1500 mm","cmc":"3,7 µm"}],"parameters_en":[{"name":"","range":"10 mm to 1500 mm","cmc":"3,7 µm"}],"parameters_zh":[{"name":"","range":"10 mm 至 1500 mm","cmc":"3,7 µm"}],"parameters_cs":[{"name":"","range":"10 mm až 1500 mm","cmc":"3,7 µm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 10 mm do 1500 mm CMC 3,7 µm\nPorównanie z płytkami wzorcowymi","reference":"Kp 01-002","norm_bases":["Kp 01-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Średnicówki mikrometryczne Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 10 mm do 1500 mm CMC 3,7 µm Mikrometrické odpichy Kalibrace – délka Porovnání s koncovými měrkami 10 mm až 1500 mm CMC 3,7 µm Kp 01-002 Srednicowki mikrometryczne Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 10 mm do 1500 mm CMC 3,7 µm Mikrometricke odpichy Kalibrace – delka Porovnani s koncovymi merkami 10 mm az 1500 mm CMC 3,7 µm Kp 01-002","search_en":"Inside micrometer gauges Calibration – length Comparison with parallel gauge blocks 10 mm to 1500 mm CMC 3,7 µm Kp 01-002","search_zh":"内径千分尺 校准 – 长度 与量块比较 10 mm 至 1500 mm CMC 3,7 µm Kp 01-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67422b6ccd69e41fac596438","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"5","test_object":"Przyrządy mikrometryczne/ średnicówki mikrometryczne","test_object_en":"Micrometer gauges / inside micrometer gauges","test_object_zh":"千分尺类量具/ 内径千分尺","test_object_cs":"Mikrometrická měřidla/ mikrometrické odpichy","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 10 mm do 500 mm","cmc":"1 µm"},{"name":"","range":"od 500 mm do 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"parameters_en":[{"name":"","range":"10 mm to 500 mm","cmc":"1 µm"},{"name":"","range":"500 mm to 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"parameters_zh":[{"name":"","range":"10 mm 至 500 mm","cmc":"1 µm"},{"name":"","range":"500 mm 至 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"parameters_cs":[{"name":"","range":"10 mm až 500 mm","cmc":"1 µm"},{"name":"","range":"500 mm až 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 10 mm do 500 mm CMC 1 µm\nod 500 mm do 2800 mm CMC (3,5·L+ 0,6) µm\nPomiar na długościomierzu","reference":"Kp 01-002","norm_bases":["Kp 01-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy mikrometryczne/ średnicówki mikrometryczne Wzorcowanie – długość Pomiar na długościomierzu od 10 mm do 500 mm CMC 1 µm od 500 mm do 2800 mm CMC (3,5·L+ 0,6) µm Mikrometrická měřidla/ mikrometrické odpichy Kalibrace – délka Měření na délkoměru 10 mm až 500 mm CMC 1 µm 500 mm až 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-002 Przyrzady mikrometryczne/ srednicowki mikrometryczne Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 10 mm do 500 mm CMC 1 µm od 500 mm do 2800 mm CMC (3,5·L+ 0,6) µm Mikrometricka meridla/ mikrometricke odpichy Kalibrace – delka Mereni na delkomeru 10 mm az 500 mm CMC 1 µm 500 mm az 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-002","search_en":"Micrometer gauges / inside micrometer gauges Calibration – length Measurement on a length gauge 10 mm to 500 mm CMC 1 µm 500 mm to 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-002","search_zh":"千分尺类量具/ 内径千分尺 校准 – 长度 在测长仪上测量 10 mm 至 500 mm CMC 1 µm 500 mm 至 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c8558f34c304c853a4ecff7","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"5","test_object":"Głowice mikrometryczne","test_object_en":"Micrometric heads","test_object_zh":"测微头","test_object_cs":"Mikrometrické hlavice","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"1 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"1 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"1 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 1 µm\nPomiar na długościomierzu","reference":"Kp 01-002","norm_bases":["Kp 01-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Głowice mikrometryczne Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 100 mm CMC 1 µm Mikrometrické hlavice Kalibrace – délka Měření na délkoměru 0 mm až 100 mm CMC 1 µm Kp 01-002 Glowice mikrometryczne Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 100 mm CMC 1 µm Mikrometricke hlavice Kalibrace – delka Mereni na delkomeru 0 mm az 100 mm CMC 1 µm Kp 01-002","search_en":"Micrometric heads Calibration – length Measurement on a length gauge 0 mm to 100 mm CMC 1 µm Kp 01-002","search_zh":"测微头 校准 – 长度 在测长仪上测量 0 mm 至 100 mm CMC 1 µm Kp 01-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"155a06da9d1d87f5647f4e4e","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"5","test_object":"Wzorce nastawcze do mikrometrów","test_object_en":"Setting gauges for micrometer gauges","test_object_zh":"千分尺校对规","test_object_cs":"Nástavné kalibry pro mikrometry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 500 mm","cmc":"1 µm"},{"name":"","range":"od 500 mm do 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"parameters_en":[{"name":"","range":"0 mm to 500 mm","cmc":"1 µm"},{"name":"","range":"500 mm to 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 500 mm","cmc":"1 µm"},{"name":"","range":"500 mm 至 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 500 mm","cmc":"1 µm"},{"name":"","range":"500 mm až 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 500 mm CMC 1 µm\nod 500 mm do 2800 mm CMC (3,5·L+ 0,6) µm\nPomiar na długościomierzu","reference":"Kp 01-002","norm_bases":["Kp 01-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorce nastawcze do mikrometrów Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 500 mm CMC 1 µm od 500 mm do 2800 mm CMC (3,5·L+ 0,6) µm Nástavné kalibry pro mikrometry Kalibrace – délka Měření na délkoměru 0 mm až 500 mm CMC 1 µm 500 mm až 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-002 Wzorce nastawcze do mikrometrow Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 500 mm CMC 1 µm od 500 mm do 2800 mm CMC (3,5·L+ 0,6) µm Nastavne kalibry pro mikrometry Kalibrace – delka Mereni na delkomeru 0 mm az 500 mm CMC 1 µm 500 mm az 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-002","search_en":"Setting gauges for micrometer gauges Calibration – length Measurement on a length gauge 0 mm to 500 mm CMC 1 µm 500 mm to 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-002","search_zh":"千分尺校对规 校准 – 长度 在测长仪上测量 0 mm 至 500 mm CMC 1 µm 500 mm 至 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8746cf141f329825bcaad02f","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"6","test_object":"Czujniki zegarowe/ zwykłe, dźwigniowe i średnicówki z czujnikiem","test_object_en":"Indicators / direct, lever indicators and internal gauges with indicator","test_object_zh":"指示表/ 直接式、杠杆式及带指示表的内径表","test_object_cs":"Úchylkoměry/ přímé, páčkové a dutinoměry s úchylkoměrem","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,5 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,5 µm"}],"technique":"Pomiar na przyrządzie do wzorcowania czujników zegarowych","technique_en":"Measurement on a dial indicator calibration instrument","technique_zh":"在百分表校准仪上测量","technique_cs":"Měření na přístroji pro kalibrace úchylkoměrů","techniques":["Pomiar na przyrządzie do wzorcowania czujników zegarowych"],"techniques_en":["Measurement on a dial indicator calibration instrument"],"techniques_zh":["在百分表校准仪上测量"],"techniques_cs":["Měření na přístroji pro kalibrace úchylkoměrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 0,5 µm\nPomiar na przyrządzie do wzorcowania czujników zegarowych","reference":"Kp 01-003","norm_bases":["Kp 01-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki zegarowe/ zwykłe, dźwigniowe i średnicówki z czujnikiem Wzorcowanie – długość Pomiar na przyrządzie do wzorcowania czujników zegarowych od 0 mm do 100 mm CMC 0,5 µm Úchylkoměry/ přímé, páčkové a dutinoměry s úchylkoměrem Kalibrace – délka Měření na přístroji pro kalibrace úchylkoměrů 0 mm až 100 mm CMC 0,5 µm Kp 01-003 Czujniki zegarowe/ zwykle, dzwigniowe i srednicowki z czujnikiem Wzorcowanie – dlugosc Pomiar na przyrzadzie do wzorcowania czujnikow zegarowych od 0 mm do 100 mm CMC 0,5 µm Uchylkomery/ prime, packove a dutinomery s uchylkomerem Kalibrace – delka Mereni na pristroji pro kalibrace uchylkomeru 0 mm az 100 mm CMC 0,5 µm Kp 01-003","search_en":"Indicators / direct, lever indicators and internal gauges with indicator Calibration – length Measurement on a dial indicator calibration instrument 0 mm to 100 mm CMC 0,5 µm Kp 01-003","search_zh":"指示表/ 直接式、杠杆式及带指示表的内径表 校准 – 长度 在百分表校准仪上测量 0 mm 至 100 mm CMC 0,5 µm Kp 01-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d8f3eb72073b7657e0b5363","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"7","test_object":"Czujniki zegarowe/ zwykłe, dźwigniowe i średnicówki z czujnikiem","test_object_en":"Indicators / direct, lever indicators and internal gauges with indicator","test_object_zh":"指示表/ 直接式、杠杆式及带指示表的内径表","test_object_cs":"Úchylkoměry/ přímé, páčkové a dutinoměry s úchylkoměrem","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 50 mm","cmc":"2,9 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"2,9 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"2,9 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 50 mm","cmc":"2,9 µm"}],"technique":"Pomiar na przyrządzie do wzorcowania czujników zegarowych","technique_en":"Measurement on a dial indicator calibration instrument","technique_zh":"在百分表校准仪上测量","technique_cs":"Měření na přístroji pro kalibrace úchylkoměrů","techniques":["Pomiar na przyrządzie do wzorcowania czujników zegarowych"],"techniques_en":["Measurement on a dial indicator calibration instrument"],"techniques_zh":["在百分表校准仪上测量"],"techniques_cs":["Měření na přístroji pro kalibrace úchylkoměrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 50 mm CMC 2,9 µm\nPomiar na przyrządzie do wzorcowania czujników zegarowych","reference":"Kp 01-003","norm_bases":["Kp 01-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki zegarowe/ zwykłe, dźwigniowe i średnicówki z czujnikiem Wzorcowanie – długość Pomiar na przyrządzie do wzorcowania czujników zegarowych od 0 mm do 50 mm CMC 2,9 µm Úchylkoměry/ přímé, páčkové a dutinoměry s úchylkoměrem Kalibrace – délka Měření na přístroji pro kalibrace úchylkoměrů 0 mm až 50 mm CMC 2,9 µm Kp 01-003 Czujniki zegarowe/ zwykle, dzwigniowe i srednicowki z czujnikiem Wzorcowanie – dlugosc Pomiar na przyrzadzie do wzorcowania czujnikow zegarowych od 0 mm do 50 mm CMC 2,9 µm Uchylkomery/ prime, packove a dutinomery s uchylkomerem Kalibrace – delka Mereni na pristroji pro kalibrace uchylkomeru 0 mm az 50 mm CMC 2,9 µm Kp 01-003","search_en":"Indicators / direct, lever indicators and internal gauges with indicator Calibration – length Measurement on a dial indicator calibration instrument 0 mm to 50 mm CMC 2,9 µm Kp 01-003","search_zh":"指示表/ 直接式、杠杆式及带指示表的内径表 校准 – 长度 在百分表校准仪上测量 0 mm 至 50 mm CMC 2,9 µm Kp 01-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0555fffb0d5c91bc36086123","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"8","test_object":"Czujniki liniowe","test_object_en":"Linear sensors","test_object_zh":"线性传感器","test_object_cs":"Lineární snímače","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,5 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,5 µm"}],"technique":"Pomiar na przyrządzie do wzorcowania czujników zegarowych","technique_en":"Measurement on a dial indicator calibration instrument","technique_zh":"在百分表校准仪上测量","technique_cs":"Měření na přístroji pro kalibrace úchylkoměrů","techniques":["Pomiar na przyrządzie do wzorcowania czujników zegarowych"],"techniques_en":["Measurement on a dial indicator calibration instrument"],"techniques_zh":["在百分表校准仪上测量"],"techniques_cs":["Měření na přístroji pro kalibrace úchylkoměrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 0,5 µm\nPomiar na przyrządzie do wzorcowania czujników zegarowych","reference":"Kp 01-003","norm_bases":["Kp 01-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki liniowe Wzorcowanie – długość Pomiar na przyrządzie do wzorcowania czujników zegarowych od 0 mm do 100 mm CMC 0,5 µm Lineární snímače Kalibrace – délka Měření na přístroji pro kalibrace úchylkoměrů 0 mm až 100 mm CMC 0,5 µm Kp 01-003 Czujniki liniowe Wzorcowanie – dlugosc Pomiar na przyrzadzie do wzorcowania czujnikow zegarowych od 0 mm do 100 mm CMC 0,5 µm Linearni snimace Kalibrace – delka Mereni na pristroji pro kalibrace uchylkomeru 0 mm az 100 mm CMC 0,5 µm Kp 01-003","search_en":"Linear sensors Calibration – length Measurement on a dial indicator calibration instrument 0 mm to 100 mm CMC 0,5 µm Kp 01-003","search_zh":"线性传感器 校准 – 长度 在百分表校准仪上测量 0 mm 至 100 mm CMC 0,5 µm Kp 01-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"672dac27e36f9050953326c0","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"9","test_object":"Przymiary kreskowe/ przymiary precyzyjne i lupy pomiarowe","test_object_en":"Rules / precise gauges and measuring magnifiers","test_object_zh":"线纹量具/ 精密尺和测量放大镜","test_object_cs":"Čárková měřidla/ přesná měřítka a měřící lupy","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,5 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,5 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 0,5 µm\nPomiar na długościomierzu","reference":"Kp 01-004","norm_bases":["Kp 01-004"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przymiary kreskowe/ przymiary precyzyjne i lupy pomiarowe Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 100 mm CMC 0,5 µm Čárková měřidla/ přesná měřítka a měřící lupy Kalibrace – délka Měření na délkoměru 0 mm až 100 mm CMC 0,5 µm Kp 01-004 Przymiary kreskowe/ przymiary precyzyjne i lupy pomiarowe Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 100 mm CMC 0,5 µm Carkova meridla/ presna meritka a merici lupy Kalibrace – delka Mereni na delkomeru 0 mm az 100 mm CMC 0,5 µm Kp 01-004","search_en":"Rules / precise gauges and measuring magnifiers Calibration – length Measurement on a length gauge 0 mm to 100 mm CMC 0,5 µm Kp 01-004","search_zh":"线纹量具/ 精密尺和测量放大镜 校准 – 长度 在测长仪上测量 0 mm 至 100 mm CMC 0,5 µm Kp 01-004","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f59c4adcabf0bde3bf548d09","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"9","test_object":"Przymiary kreskowe/ przymiary precyzyjne i lupy pomiarowe","test_object_en":"Rules / precise gauges and measuring magnifiers","test_object_zh":"线纹量具/ 精密尺和测量放大镜","test_object_cs":"Čárková měřidla/ přesná měřítka a měřící lupy","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 200 mm","cmc":"(5·L+ 0,65) µm"},{"name":"","range":"od 200 mm do 1000 mm","cmc":"(2,7·L+ 1,2) µm"}],"parameters_en":[{"name":"","range":"0 mm to 200 mm","cmc":"(5·L+ 0,65) µm"},{"name":"","range":"200 mm to 1000 mm","cmc":"(2,7·L+ 1,2) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 200 mm","cmc":"(5·L+ 0,65) µm"},{"name":"","range":"200 mm 至 1000 mm","cmc":"(2,7·L+ 1,2) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 200 mm","cmc":"(5·L+ 0,65) µm"},{"name":"","range":"200 mm až 1000 mm","cmc":"(2,7·L+ 1,2) µm"}],"technique":"Pomiar na mikroskopie","technique_en":"Measurement on a microscope","technique_zh":"在显微镜上测量","technique_cs":"Měření na mikroskopu","techniques":["Pomiar na mikroskopie"],"techniques_en":["Measurement on a microscope"],"techniques_zh":["在显微镜上测量"],"techniques_cs":["Měření na mikroskopu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 200 mm CMC (5·L+ 0,65) µm\nod 200 mm do 1000 mm CMC (2,7·L+ 1,2) µm\nPomiar na mikroskopie","reference":"Kp 01-004","norm_bases":["Kp 01-004"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przymiary kreskowe/ przymiary precyzyjne i lupy pomiarowe Wzorcowanie – długość Pomiar na mikroskopie od 0 mm do 200 mm CMC (5·L+ 0,65) µm od 200 mm do 1000 mm CMC (2,7·L+ 1,2) µm Čárková měřidla/ přesná měřítka a měřící lupy Kalibrace – délka Měření na mikroskopu 0 mm až 200 mm CMC (5·L+ 0,65) µm 200 mm až 1000 mm CMC (2,7·L+ 1,2) µm Kp 01-004 Przymiary kreskowe/ przymiary precyzyjne i lupy pomiarowe Wzorcowanie – dlugosc Pomiar na mikroskopie od 0 mm do 200 mm CMC (5·L+ 0,65) µm od 200 mm do 1000 mm CMC (2,7·L+ 1,2) µm Carkova meridla/ presna meritka a merici lupy Kalibrace – delka Mereni na mikroskopu 0 mm az 200 mm CMC (5·L+ 0,65) µm 200 mm az 1000 mm CMC (2,7·L+ 1,2) µm Kp 01-004","search_en":"Rules / precise gauges and measuring magnifiers Calibration – length Measurement on a microscope 0 mm to 200 mm CMC (5·L+ 0,65) µm 200 mm to 1000 mm CMC (2,7·L+ 1,2) µm Kp 01-004","search_zh":"线纹量具/ 精密尺和测量放大镜 校准 – 长度 在显微镜上测量 0 mm 至 200 mm CMC (5·L+ 0,65) µm 200 mm 至 1000 mm CMC (2,7·L+ 1,2) µm Kp 01-004","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"11bc718357e9f45250b67d44","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"9","test_object":"Przymiary stalowe","test_object_en":"Steel rules","test_object_zh":"钢直尺","test_object_cs":"Ocelová měřítka","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"39 µm"},{"name":"","range":"od 1000 mm do 2000 mm","cmc":"56 µm"},{"name":"","range":"od 2000 mm do 3000 mm","cmc":"68 µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"39 µm"},{"name":"","range":"1000 mm to 2000 mm","cmc":"56 µm"},{"name":"","range":"2000 mm to 3000 mm","cmc":"68 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"39 µm"},{"name":"","range":"1000 mm 至 2000 mm","cmc":"56 µm"},{"name":"","range":"2000 mm 至 3000 mm","cmc":"68 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"39 µm"},{"name":"","range":"1000 mm až 2000 mm","cmc":"56 µm"},{"name":"","range":"2000 mm až 3000 mm","cmc":"68 µm"}],"technique":"Porównanie z wzorcowym przymiarem stalowym","technique_en":"Comparison with a reference steel ruler","technique_zh":"与标准钢尺比较","technique_cs":"Porovnání s etalonovým ocelovým měřítkem","techniques":["Porównanie z wzorcowym przymiarem stalowym"],"techniques_en":["Comparison with a reference steel ruler"],"techniques_zh":["与标准钢尺比较"],"techniques_cs":["Porovnání s etalonovým ocelovým měřítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 1000 mm CMC 39 µm\nod 1000 mm do 2000 mm CMC 56 µm\nod 2000 mm do 3000 mm CMC 68 µm\nPorównanie z wzorcowym przymiarem stalowym","reference":"Kp 01-004","norm_bases":["Kp 01-004"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przymiary stalowe Wzorcowanie – długość Porównanie z wzorcowym przymiarem stalowym od 0 mm do 1000 mm CMC 39 µm od 1000 mm do 2000 mm CMC 56 µm od 2000 mm do 3000 mm CMC 68 µm Ocelová měřítka Kalibrace – délka Porovnání s etalonovým ocelovým měřítkem 0 mm až 1000 mm CMC 39 µm 1000 mm až 2000 mm CMC 56 µm 2000 mm až 3000 mm CMC 68 µm Kp 01-004 Przymiary stalowe Wzorcowanie – dlugosc Porownanie z wzorcowym przymiarem stalowym od 0 mm do 1000 mm CMC 39 µm od 1000 mm do 2000 mm CMC 56 µm od 2000 mm do 3000 mm CMC 68 µm Ocelova meritka Kalibrace – delka Porovnani s etalonovym ocelovym meritkem 0 mm az 1000 mm CMC 39 µm 1000 mm az 2000 mm CMC 56 µm 2000 mm az 3000 mm CMC 68 µm Kp 01-004","search_en":"Steel rules Calibration – length Comparison with a reference steel ruler 0 mm to 1000 mm CMC 39 µm 1000 mm to 2000 mm CMC 56 µm 2000 mm to 3000 mm CMC 68 µm Kp 01-004","search_zh":"钢直尺 校准 – 长度 与标准钢尺比较 0 mm 至 1000 mm CMC 39 µm 1000 mm 至 2000 mm CMC 56 µm 2000 mm 至 3000 mm CMC 68 µm Kp 01-004","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"afce6ad26eead3318c28c35a","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"9","test_object":"Miary zwijane","test_object_en":"Tape measures","test_object_zh":"卷尺","test_object_cs":"Svinovací metry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 10 m","cmc":"(0,3·L+ 0,035) mm"}],"parameters_en":[{"name":"","range":"0 m to 10 m","cmc":"(0,3·L+ 0,035) mm"}],"parameters_zh":[{"name":"","range":"0 m 至 10 m","cmc":"(0,3·L+ 0,035) mm"}],"parameters_cs":[{"name":"","range":"0 m až 10 m","cmc":"(0,3·L+ 0,035) mm"}],"technique":"Porównanie z wzorcowym torem pomiarowym","technique_en":"Comparison with a reference track","technique_zh":"与标准测量轨道比较","technique_cs":"Porovnání s etalonovou tratí","techniques":["Porównanie z wzorcowym torem pomiarowym"],"techniques_en":["Comparison with a reference track"],"techniques_zh":["与标准测量轨道比较"],"techniques_cs":["Porovnání s etalonovou tratí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 10 m CMC (0,3·L+ 0,035) mm\nPorównanie z wzorcowym torem pomiarowym","reference":"Kp 01-004","norm_bases":["Kp 01-004"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Miary zwijane Wzorcowanie – długość Porównanie z wzorcowym torem pomiarowym od 0 m do 10 m CMC (0,3·L+ 0,035) mm Svinovací metry Kalibrace – délka Porovnání s etalonovou tratí 0 m až 10 m CMC (0,3·L+ 0,035) mm Kp 01-004 Miary zwijane Wzorcowanie – dlugosc Porownanie z wzorcowym torem pomiarowym od 0 m do 10 m CMC (0,3·L+ 0,035) mm Svinovaci metry Kalibrace – delka Porovnani s etalonovou trati 0 m az 10 m CMC (0,3·L+ 0,035) mm Kp 01-004","search_en":"Tape measures Calibration – length Comparison with a reference track 0 m to 10 m CMC (0,3·L+ 0,035) mm Kp 01-004","search_zh":"卷尺 校准 – 长度 与标准测量轨道比较 0 m 至 10 m CMC (0,3·L+ 0,035) mm Kp 01-004","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2aafd2ae2227fae2b424101c","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"9","test_object":"Taśmy miernicze, metry drewniane i dwumetrówki","test_object_en":"Tape measures, wooden rulers and rulers of 2m length","test_object_zh":"测量带尺、木尺和两米尺","test_object_cs":"Měřičská pásma, dřevěné metry a dvoumetry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 300 m","cmc":"(0,03·L+ 0,3) mm"}],"parameters_en":[{"name":"","range":"0 m to 300 m","cmc":"(0,03·L+ 0,3) mm"}],"parameters_zh":[{"name":"","range":"0 m 至 300 m","cmc":"(0,03·L+ 0,3) mm"}],"parameters_cs":[{"name":"","range":"0 m až 300 m","cmc":"(0,03·L+ 0,3) mm"}],"technique":"Porównanie z wzorcowym torem pomiarowym","technique_en":"Comparison with a reference track","technique_zh":"与标准测量轨道比较","technique_cs":"Porovnání s etalonovou tratí","techniques":["Porównanie z wzorcowym torem pomiarowym"],"techniques_en":["Comparison with a reference track"],"techniques_zh":["与标准测量轨道比较"],"techniques_cs":["Porovnání s etalonovou tratí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 300 m CMC (0,03·L+ 0,3) mm\nPorównanie z wzorcowym torem pomiarowym","reference":"Kp 01-004","norm_bases":["Kp 01-004"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Taśmy miernicze, metry drewniane i dwumetrówki Wzorcowanie – długość Porównanie z wzorcowym torem pomiarowym od 0 m do 300 m CMC (0,03·L+ 0,3) mm Měřičská pásma, dřevěné metry a dvoumetry Kalibrace – délka Porovnání s etalonovou tratí 0 m až 300 m CMC (0,03·L+ 0,3) mm Kp 01-004 Tasmy miernicze, metry drewniane i dwumetrowki Wzorcowanie – dlugosc Porownanie z wzorcowym torem pomiarowym od 0 m do 300 m CMC (0,03·L+ 0,3) mm Mericska pasma, drevene metry a dvoumetry Kalibrace – delka Porovnani s etalonovou trati 0 m az 300 m CMC (0,03·L+ 0,3) mm Kp 01-004","search_en":"Tape measures, wooden rulers and rulers of 2m length Calibration – length Comparison with a reference track 0 m to 300 m CMC (0,03·L+ 0,3) mm Kp 01-004","search_zh":"测量带尺、木尺和两米尺 校准 – 长度 与标准测量轨道比较 0 m 至 300 m CMC (0,03·L+ 0,3) mm Kp 01-004","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4bbb7e08c44fb143e2645928","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"10","test_object":"Przymiary kreskowe/ przymiary stalowe","test_object_en":"Rules / steel gauges","test_object_zh":"线纹量具/ 钢尺","test_object_cs":"Čárková měřidla/ ocelová měřítka","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 500 mm","cmc":"0,12 mm"}],"parameters_en":[{"name":"","range":"0 mm to 500 mm","cmc":"0,12 mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 500 mm","cmc":"0,12 mm"}],"parameters_cs":[{"name":"","range":"0 mm až 500 mm","cmc":"0,12 mm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 500 mm CMC 0,12 mm\nPorównanie z płytkami wzorcowymi","reference":"Kp 01-004, Kp 01-015","norm_bases":["Kp 01-004","Kp 01-015"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przymiary kreskowe/ przymiary stalowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 500 mm CMC 0,12 mm Čárková měřidla/ ocelová měřítka Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 500 mm CMC 0,12 mm Kp 01-004, Kp 01-015 Przymiary kreskowe/ przymiary stalowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 500 mm CMC 0,12 mm Carkova meridla/ ocelova meritka Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 500 mm CMC 0,12 mm Kp 01-004, Kp 01-015","search_en":"Rules / steel gauges Calibration – length Comparison with parallel gauge blocks 0 mm to 500 mm CMC 0,12 mm Kp 01-004, Kp 01-015","search_zh":"线纹量具/ 钢尺 校准 – 长度 与量块比较 0 mm 至 500 mm CMC 0,12 mm Kp 01-004, Kp 01-015","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b8aab290f80df4de8608b622","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"10","test_object":"Miary zwijane","test_object_en":"Tape measures","test_object_zh":"卷尺","test_object_cs":"Svinovací metry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 10 m","cmc":"(0,07·L+ 0,19) mm"}],"parameters_en":[{"name":"","range":"0 m to 10 m","cmc":"(0,07·L+ 0,19) mm"}],"parameters_zh":[{"name":"","range":"0 m 至 10 m","cmc":"(0,07·L+ 0,19) mm"}],"parameters_cs":[{"name":"","range":"0 m až 10 m","cmc":"(0,07·L+ 0,19) mm"}],"technique":"Porównanie z wzorcowym przymiarem stalowym","technique_en":"Comparison with a reference steel ruler","technique_zh":"与标准钢尺比较","technique_cs":"Porovnání s etalonovým ocelovým měřítkem","techniques":["Porównanie z wzorcowym przymiarem stalowym"],"techniques_en":["Comparison with a reference steel ruler"],"techniques_zh":["与标准钢尺比较"],"techniques_cs":["Porovnání s etalonovým ocelovým měřítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 10 m CMC (0,07·L+ 0,19) mm\nPorównanie z wzorcowym przymiarem stalowym","reference":"Kp 01-004","norm_bases":["Kp 01-004"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Miary zwijane Wzorcowanie – długość Porównanie z wzorcowym przymiarem stalowym od 0 m do 10 m CMC (0,07·L+ 0,19) mm Svinovací metry Kalibrace – délka Porovnání s etalonovým ocelovým měřítkem 0 m až 10 m CMC (0,07·L+ 0,19) mm Kp 01-004 Miary zwijane Wzorcowanie – dlugosc Porownanie z wzorcowym przymiarem stalowym od 0 m do 10 m CMC (0,07·L+ 0,19) mm Svinovaci metry Kalibrace – delka Porovnani s etalonovym ocelovym meritkem 0 m az 10 m CMC (0,07·L+ 0,19) mm Kp 01-004","search_en":"Tape measures Calibration – length Comparison with a reference steel ruler 0 m to 10 m CMC (0,07·L+ 0,19) mm Kp 01-004","search_zh":"卷尺 校准 – 长度 与标准钢尺比较 0 m 至 10 m CMC (0,07·L+ 0,19) mm Kp 01-004","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"49b17629389e3c43466df35f","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Pierścienie nastawcze i sprawdziany szczękowe","test_object_en":"Setting rings and snap gauges","test_object_zh":"校对环和卡规","test_object_cs":"Nástavné kroužky a třmenové kalibry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,95 mm do 10 mm","cmc":"1 µm"},{"name":"","range":"od 10 mm do 330 mm","cmc":"(4,3·L+ 0,7) µm"}],"parameters_en":[{"name":"","range":"0,95 mm to 10 mm","cmc":"1 µm"},{"name":"","range":"10 mm to 330 mm","cmc":"(4,3·L+ 0,7) µm"}],"parameters_zh":[{"name":"","range":"0,95 mm 至 10 mm","cmc":"1 µm"},{"name":"","range":"10 mm 至 330 mm","cmc":"(4,3·L+ 0,7) µm"}],"parameters_cs":[{"name":"","range":"0,95 mm až 10 mm","cmc":"1 µm"},{"name":"","range":"10 mm až 330 mm","cmc":"(4,3·L+ 0,7) µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0,95 mm do 10 mm CMC 1 µm\nod 10 mm do 330 mm CMC (4,3·L+ 0,7) µm\nPomiar na długościomierzu","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pierścienie nastawcze i sprawdziany szczękowe Wzorcowanie – długość Pomiar na długościomierzu od 0,95 mm do 10 mm CMC 1 µm od 10 mm do 330 mm CMC (4,3·L+ 0,7) µm Nástavné kroužky a třmenové kalibry Kalibrace – délka Měření na délkoměru 0,95 mm až 10 mm CMC 1 µm 10 mm až 330 mm CMC (4,3·L+ 0,7) µm Kp 01-005 Pierscienie nastawcze i sprawdziany szczekowe Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0,95 mm do 10 mm CMC 1 µm od 10 mm do 330 mm CMC (4,3·L+ 0,7) µm Nastavne krouzky a trmenove kalibry Kalibrace – delka Mereni na delkomeru 0,95 mm az 10 mm CMC 1 µm 10 mm az 330 mm CMC (4,3·L+ 0,7) µm Kp 01-005","search_en":"Setting rings and snap gauges Calibration – length Measurement on a length gauge 0,95 mm to 10 mm CMC 1 µm 10 mm to 330 mm CMC (4,3·L+ 0,7) µm Kp 01-005","search_zh":"校对环和卡规 校准 – 长度 在测长仪上测量 0,95 mm 至 10 mm CMC 1 µm 10 mm 至 330 mm CMC (4,3·L+ 0,7) µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7529a18796f24dca47ebbfae","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Sprawdziany walcowe","test_object_en":"Cylindrical gauges","test_object_zh":"圆柱量规","test_object_cs":"Válečkové kalibry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,5 µm"},{"name":"","range":"od 100 mm do 500 mm","cmc":"1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"},{"name":"","range":"100 mm to 500 mm","cmc":"1 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,5 µm"},{"name":"","range":"100 mm 至 500 mm","cmc":"1 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,5 µm"},{"name":"","range":"100 mm až 500 mm","cmc":"1 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 100 mm CMC 0,5 µm\nod 100 mm do 500 mm CMC 1 µm\nPomiar na długościomierzu","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany walcowe Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 100 mm CMC 0,5 µm od 100 mm do 500 mm CMC 1 µm Válečkové kalibry Kalibrace – délka Měření na délkoměru 0 mm až 100 mm CMC 0,5 µm 100 mm až 500 mm CMC 1 µm Kp 01-005 Sprawdziany walcowe Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 100 mm CMC 0,5 µm od 100 mm do 500 mm CMC 1 µm Valeckove kalibry Kalibrace – delka Mereni na delkomeru 0 mm az 100 mm CMC 0,5 µm 100 mm az 500 mm CMC 1 µm Kp 01-005","search_en":"Cylindrical gauges Calibration – length Measurement on a length gauge 0 mm to 100 mm CMC 0,5 µm 100 mm to 500 mm CMC 1 µm Kp 01-005","search_zh":"圆柱量规 校准 – 长度 在测长仪上测量 0 mm 至 100 mm CMC 0,5 µm 100 mm 至 500 mm CMC 1 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"70e63f2b18ffbb66cb6830a5","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Sprawdziany płaskie","test_object_en":"Slot gauges","test_object_zh":"平面量规","test_object_cs":"Ploché kalibry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,5 µm"},{"name":"","range":"od 100 mm do 500 mm","cmc":"1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"},{"name":"","range":"100 mm to 500 mm","cmc":"1 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,5 µm"},{"name":"","range":"100 mm 至 500 mm","cmc":"1 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,5 µm"},{"name":"","range":"100 mm až 500 mm","cmc":"1 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 100 mm CMC 0,5 µm\nod 100 mm do 500 mm CMC 1 µm\nPomiar na długościomierzu","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany płaskie Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 100 mm CMC 0,5 µm od 100 mm do 500 mm CMC 1 µm Ploché kalibry Kalibrace – délka Měření na délkoměru 0 mm až 100 mm CMC 0,5 µm 100 mm až 500 mm CMC 1 µm Kp 01-005 Sprawdziany plaskie Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 100 mm CMC 0,5 µm od 100 mm do 500 mm CMC 1 µm Ploche kalibry Kalibrace – delka Mereni na delkomeru 0 mm az 100 mm CMC 0,5 µm 100 mm az 500 mm CMC 1 µm Kp 01-005","search_en":"Slot gauges Calibration – length Measurement on a length gauge 0 mm to 100 mm CMC 0,5 µm 100 mm to 500 mm CMC 1 µm Kp 01-005","search_zh":"平面量规 校准 – 长度 在测长仪上测量 0 mm 至 100 mm CMC 0,5 µm 100 mm 至 500 mm CMC 1 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9c4f808362db12e8d663e886","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Szczelinomierze listkowe i kliny","test_object_en":"Feeler gauges and wedges","test_object_zh":"塞尺和楔规","test_object_cs":"Lístkové spároměry a klínky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,5 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,5 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 0,5 µm\nPomiar na długościomierzu","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Szczelinomierze listkowe i kliny Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 100 mm CMC 0,5 µm Lístkové spároměry a klínky Kalibrace – délka Měření na délkoměru 0 mm až 100 mm CMC 0,5 µm Kp 01-005 Szczelinomierze listkowe i kliny Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 100 mm CMC 0,5 µm Listkove sparomery a klinky Kalibrace – delka Mereni na delkomeru 0 mm az 100 mm CMC 0,5 µm Kp 01-005","search_en":"Feeler gauges and wedges Calibration – length Measurement on a length gauge 0 mm to 100 mm CMC 0,5 µm Kp 01-005","search_zh":"塞尺和楔规 校准 – 长度 在测长仪上测量 0 mm 至 100 mm CMC 0,5 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b9b7ea997a01165caff2b1ec","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Wałeczki pomiarowe i druciki pomiarowe","test_object_en":"Cylindrical gauges and measuring wires","test_object_zh":"量棒和量针","test_object_cs":"Válečkové měrky a měřící drátky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,5 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,5 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 0,5 µm\nPomiar na długościomierzu","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wałeczki pomiarowe i druciki pomiarowe Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 100 mm CMC 0,5 µm Válečkové měrky a měřící drátky Kalibrace – délka Měření na délkoměru 0 mm až 100 mm CMC 0,5 µm Kp 01-005 Waleczki pomiarowe i druciki pomiarowe Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 100 mm CMC 0,5 µm Valeckove merky a merici dratky Kalibrace – delka Mereni na delkomeru 0 mm az 100 mm CMC 0,5 µm Kp 01-005","search_en":"Cylindrical gauges and measuring wires Calibration – length Measurement on a length gauge 0 mm to 100 mm CMC 0,5 µm Kp 01-005","search_zh":"量棒和量针 校准 – 长度 在测长仪上测量 0 mm 至 100 mm CMC 0,5 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5c2a3f46e8b4d2c4c2e34484","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Wzorce nastawcze do grubościomierzy powłok","test_object_en":"Setting gauges for layer thickness gauges","test_object_zh":"涂层测厚仪校对规","test_object_cs":"Nástavné kalibry pro tloušťkoměry vrstev","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"1 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"1 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"1 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 1 µm\nPomiar na długościomierzu","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorce nastawcze do grubościomierzy powłok Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 100 mm CMC 1 µm Nástavné kalibry pro tloušťkoměry vrstev Kalibrace – délka Měření na délkoměru 0 mm až 100 mm CMC 1 µm Kp 01-005 Wzorce nastawcze do grubosciomierzy powlok Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 100 mm CMC 1 µm Nastavne kalibry pro tloustkomery vrstev Kalibrace – delka Mereni na delkomeru 0 mm az 100 mm CMC 1 µm Kp 01-005","search_en":"Setting gauges for layer thickness gauges Calibration – length Measurement on a length gauge 0 mm to 100 mm CMC 1 µm Kp 01-005","search_zh":"涂层测厚仪校对规 校准 – 长度 在测长仪上测量 0 mm 至 100 mm CMC 1 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7626952cb93dfd097d5406f7","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Sprawdziany gwintowe - trzpienie","test_object_en":"Thread gauges – plug gauges","test_object_zh":"螺纹量规 - 塞规","test_object_cs":"Závitové kalibry - trny","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 300 mm","cmc":"3,1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 300 mm","cmc":"3,1 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 300 mm","cmc":"3,1 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 300 mm","cmc":"3,1 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 300 mm CMC 3,1 µm\nPomiar na długościomierzu","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany gwintowe - trzpienie Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 300 mm CMC 3,1 µm Závitové kalibry - trny Kalibrace – délka Měření na délkoměru 0 mm až 300 mm CMC 3,1 µm Kp 01-005 Sprawdziany gwintowe - trzpienie Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 300 mm CMC 3,1 µm Zavitove kalibry - trny Kalibrace – delka Mereni na delkomeru 0 mm az 300 mm CMC 3,1 µm Kp 01-005","search_en":"Thread gauges – plug gauges Calibration – length Measurement on a length gauge 0 mm to 300 mm CMC 3,1 µm Kp 01-005","search_zh":"螺纹量规 - 塞规 校准 – 长度 在测长仪上测量 0 mm 至 300 mm CMC 3,1 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6184088cc7f66f296215f8a6","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Sprawdziany gwintowe - pierścienie","test_object_en":"Thread gauges - female","test_object_zh":"螺纹量规 - 环规","test_object_cs":"Závitové kalibry - kroužky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 2 mm do 200 mm","cmc":"4 µm"}],"parameters_en":[{"name":"","range":"2 mm to 200 mm","cmc":"4 µm"}],"parameters_zh":[{"name":"","range":"2 mm 至 200 mm","cmc":"4 µm"}],"parameters_cs":[{"name":"","range":"2 mm až 200 mm","cmc":"4 µm"}],"technique":"Pomiar na mikroskopie","technique_en":"Measurement on a microscope","technique_zh":"在显微镜上测量","technique_cs":"Měření na mikroskopu","techniques":["Pomiar na mikroskopie"],"techniques_en":["Measurement on a microscope"],"techniques_zh":["在显微镜上测量"],"techniques_cs":["Měření na mikroskopu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 2 mm do 200 mm CMC 4 µm\nPomiar na mikroskopie","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany gwintowe - pierścienie Wzorcowanie – długość Pomiar na mikroskopie od 2 mm do 200 mm CMC 4 µm Závitové kalibry - kroužky Kalibrace – délka Měření na mikroskopu 2 mm až 200 mm CMC 4 µm Kp 01-005 Sprawdziany gwintowe - pierscienie Wzorcowanie – dlugosc Pomiar na mikroskopie od 2 mm do 200 mm CMC 4 µm Zavitove kalibry - krouzky Kalibrace – delka Mereni na mikroskopu 2 mm az 200 mm CMC 4 µm Kp 01-005","search_en":"Thread gauges - female Calibration – length Measurement on a microscope 2 mm to 200 mm CMC 4 µm Kp 01-005","search_zh":"螺纹量规 - 环规 校准 – 长度 在显微镜上测量 2 mm 至 200 mm CMC 4 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eee70f8087aa5ccf71384f24","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Sprawdziany gwintowe - stożkowe","test_object_en":"Thread gauges - conical","test_object_zh":"螺纹量规 - 锥形","test_object_cs":"Závitové kalibry - kuželové","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"5 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"5 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"5 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 5 µm\nPomiar na długościomierzu","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany gwintowe - stożkowe Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 100 mm CMC 5 µm Závitové kalibry - kuželové Kalibrace – délka Měření na délkoměru 0 mm až 100 mm CMC 5 µm Kp 01-005 Sprawdziany gwintowe - stozkowe Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 100 mm CMC 5 µm Zavitove kalibry - kuzelove Kalibrace – delka Mereni na delkomeru 0 mm az 100 mm CMC 5 µm Kp 01-005","search_en":"Thread gauges - conical Calibration – length Measurement on a length gauge 0 mm to 100 mm CMC 5 µm Kp 01-005","search_zh":"螺纹量规 - 锥形 校准 – 长度 在测长仪上测量 0 mm 至 100 mm CMC 5 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dc62c29c757b6d424268db86","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Kubki wypływowe - średnica","test_object_en":"Efflux viscometers - diameter","test_object_zh":"流出杯 - 直径","test_object_cs":"Výtokové pohárky- průměr","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 10 mm","cmc":"4 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"4 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 10 mm","cmc":"4 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 10 mm","cmc":"4 µm"}],"technique":"Pomiar na mikroskopie","technique_en":"Measurement on a microscope","technique_zh":"在显微镜上测量","technique_cs":"Měření na mikroskopu","techniques":["Pomiar na mikroskopie"],"techniques_en":["Measurement on a microscope"],"techniques_zh":["在显微镜上测量"],"techniques_cs":["Měření na mikroskopu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 10 mm CMC 4 µm\nPomiar na mikroskopie","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kubki wypływowe - średnica Wzorcowanie – długość Pomiar na mikroskopie od 0 mm do 10 mm CMC 4 µm Výtokové pohárky- průměr Kalibrace – délka Měření na mikroskopu 0 mm až 10 mm CMC 4 µm Kp 01-005 Kubki wyplywowe - srednica Wzorcowanie – dlugosc Pomiar na mikroskopie od 0 mm do 10 mm CMC 4 µm Vytokove poharky- prumer Kalibrace – delka Mereni na mikroskopu 0 mm az 10 mm CMC 4 µm Kp 01-005","search_en":"Efflux viscometers - diameter Calibration – length Measurement on a microscope 0 mm to 10 mm CMC 4 µm Kp 01-005","search_zh":"流出杯 - 直径 校准 – 长度 在显微镜上测量 0 mm 至 10 mm CMC 4 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ead1fd6407ced79a75219b01","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"12","test_object":"Wałeczki pomiarowe","test_object_en":"Cylindrical gauges","test_object_zh":"量棒","test_object_cs":"Válečkové měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"2 µm"},{"name":"","range":"od 0 mm do 30 mm","cmc":"1,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"2 µm"},{"name":"","range":"0 mm to 30 mm","cmc":"1,5 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"2 µm"},{"name":"","range":"0 mm 至 30 mm","cmc":"1,5 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"2 µm"},{"name":"","range":"0 mm až 30 mm","cmc":"1,5 µm"}],"technique":"Pomiar mikrometrem","technique_en":"Measurement using a micrometer","technique_zh":"用千分尺测量","technique_cs":"Měření mikrometrem","techniques":["Pomiar mikrometrem"],"techniques_en":["Measurement using a micrometer"],"techniques_zh":["用千分尺测量"],"techniques_cs":["Měření mikrometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 100 mm CMC 2 µm\nod 0 mm do 30 mm CMC 1,5 µm\nPomiar mikrometrem","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wałeczki pomiarowe Wzorcowanie – długość Pomiar mikrometrem od 0 mm do 100 mm CMC 2 µm od 0 mm do 30 mm CMC 1,5 µm Válečkové měrky Kalibrace – délka Měření mikrometrem 0 mm až 100 mm CMC 2 µm 0 mm až 30 mm CMC 1,5 µm Kp 01-005 Waleczki pomiarowe Wzorcowanie – dlugosc Pomiar mikrometrem od 0 mm do 100 mm CMC 2 µm od 0 mm do 30 mm CMC 1,5 µm Valeckove merky Kalibrace – delka Mereni mikrometrem 0 mm az 100 mm CMC 2 µm 0 mm az 30 mm CMC 1,5 µm Kp 01-005","search_en":"Cylindrical gauges Calibration – length Measurement using a micrometer 0 mm to 100 mm CMC 2 µm 0 mm to 30 mm CMC 1,5 µm Kp 01-005","search_zh":"量棒 校准 – 长度 用千分尺测量 0 mm 至 100 mm CMC 2 µm 0 mm 至 30 mm CMC 1,5 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e1604d2a089b2f27b0df0fa3","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"12","test_object":"Sprawdziany płaskie","test_object_en":"Slot gauges","test_object_zh":"平面量规","test_object_cs":"Ploché kalibry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"2 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"2 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"2 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"2 µm"}],"technique":"Pomiar mikrometrem","technique_en":"Measurement using a micrometer","technique_zh":"用千分尺测量","technique_cs":"Měření mikrometrem","techniques":["Pomiar mikrometrem"],"techniques_en":["Measurement using a micrometer"],"techniques_zh":["用千分尺测量"],"techniques_cs":["Měření mikrometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 2 µm\nPomiar mikrometrem","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany płaskie Wzorcowanie – długość Pomiar mikrometrem od 0 mm do 100 mm CMC 2 µm Ploché kalibry Kalibrace – délka Měření mikrometrem 0 mm až 100 mm CMC 2 µm Kp 01-005 Sprawdziany plaskie Wzorcowanie – dlugosc Pomiar mikrometrem od 0 mm do 100 mm CMC 2 µm Ploche kalibry Kalibrace – delka Mereni mikrometrem 0 mm az 100 mm CMC 2 µm Kp 01-005","search_en":"Slot gauges Calibration – length Measurement using a micrometer 0 mm to 100 mm CMC 2 µm Kp 01-005","search_zh":"平面量规 校准 – 长度 用千分尺测量 0 mm 至 100 mm CMC 2 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"170712720146ec38614dd282","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"12","test_object":"Szczelinomierze listkowe i kliny","test_object_en":"Feeler gauges and wedges","test_object_zh":"塞尺和楔规","test_object_cs":"Lístkové spároměry a klínky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 30 mm","cmc":"1,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 30 mm","cmc":"1,5 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 30 mm","cmc":"1,5 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 30 mm","cmc":"1,5 µm"}],"technique":"Pomiar mikrometrem","technique_en":"Measurement using a micrometer","technique_zh":"用千分尺测量","technique_cs":"Měření mikrometrem","techniques":["Pomiar mikrometrem"],"techniques_en":["Measurement using a micrometer"],"techniques_zh":["用千分尺测量"],"techniques_cs":["Měření mikrometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 30 mm CMC 1,5 µm\nPomiar mikrometrem","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Szczelinomierze listkowe i kliny Wzorcowanie – długość Pomiar mikrometrem od 0 mm do 30 mm CMC 1,5 µm Lístkové spároměry a klínky Kalibrace – délka Měření mikrometrem 0 mm až 30 mm CMC 1,5 µm Kp 01-005 Szczelinomierze listkowe i kliny Wzorcowanie – dlugosc Pomiar mikrometrem od 0 mm do 30 mm CMC 1,5 µm Listkove sparomery a klinky Kalibrace – delka Mereni mikrometrem 0 mm az 30 mm CMC 1,5 µm Kp 01-005","search_en":"Feeler gauges and wedges Calibration – length Measurement using a micrometer 0 mm to 30 mm CMC 1,5 µm Kp 01-005","search_zh":"塞尺和楔规 校准 – 长度 用千分尺测量 0 mm 至 30 mm CMC 1,5 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c46b11aa49d1cb07470caa44","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"12","test_object":"Sprawdziany gwintowe - trzpienie","test_object_en":"Thread gauges – plug gauges","test_object_zh":"螺纹量规 - 塞规","test_object_cs":"Závitové kalibry- trny","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"5 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"5 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"5 µm"}],"technique":"Pomiar mikrometrem","technique_en":"Measurement using a micrometer","technique_zh":"用千分尺测量","technique_cs":"Měření mikrometrem","techniques":["Pomiar mikrometrem"],"techniques_en":["Measurement using a micrometer"],"techniques_zh":["用千分尺测量"],"techniques_cs":["Měření mikrometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 5 µm\nPomiar mikrometrem","reference":"Kp 01-005","norm_bases":["Kp 01-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany gwintowe - trzpienie Wzorcowanie – długość Pomiar mikrometrem od 0 mm do 100 mm CMC 5 µm Závitové kalibry- trny Kalibrace – délka Měření mikrometrem 0 mm až 100 mm CMC 5 µm Kp 01-005 Sprawdziany gwintowe - trzpienie Wzorcowanie – dlugosc Pomiar mikrometrem od 0 mm do 100 mm CMC 5 µm Zavitove kalibry- trny Kalibrace – delka Mereni mikrometrem 0 mm az 100 mm CMC 5 µm Kp 01-005","search_en":"Thread gauges – plug gauges Calibration – length Measurement using a micrometer 0 mm to 100 mm CMC 5 µm Kp 01-005","search_zh":"螺纹量规 - 塞规 校准 – 长度 用千分尺测量 0 mm 至 100 mm CMC 5 µm Kp 01-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a8d333380a0ae33500e82096","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"13","test_object":"Grubościomierze i macki","test_object_en":"Thickness gauges and callipers","test_object_zh":"测厚仪和卡钳","test_object_cs":"Tloušťkoměry a hmatadla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"pomiar zewnętrzny","range":"od 0 mm do 500 mm","cmc":"2,2 µm"},{"name":"pomiar wewnętrzny","range":"od 3 mm do 500 mm","cmc":"3,7 µm"}],"parameters_en":[{"name":"external measurement","range":"0 mm to 500 mm","cmc":"2,2 µm"},{"name":"internal measurement","range":"3 mm to 500 mm","cmc":"3,7 µm"}],"parameters_zh":[{"name":"外测量","range":"0 mm 至 500 mm","cmc":"2,2 µm"},{"name":"内测量","range":"3 mm 至 500 mm","cmc":"3,7 µm"}],"parameters_cs":[{"name":"vnější měření","range":"0 mm až 500 mm","cmc":"2,2 µm"},{"name":"vnitřní měření","range":"3 mm až 500 mm","cmc":"3,7 µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"使用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["使用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\npomiar zewnętrzny od 0 mm do 500 mm CMC 2,2 µm\npomiar wewnętrzny od 3 mm do 500 mm CMC 3,7 µm\nPomiar za pomocą płytek wzorcowych","reference":"Kp 01-010","norm_bases":["Kp 01-010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grubościomierze i macki Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych pomiar zewnętrzny od 0 mm do 500 mm CMC 2,2 µm pomiar wewnętrzny od 3 mm do 500 mm CMC 3,7 µm Tloušťkoměry a hmatadla Kalibrace – délka Měření pomocí koncových měrek vnější měření 0 mm až 500 mm CMC 2,2 µm vnitřní měření 3 mm až 500 mm CMC 3,7 µm Kp 01-010 Grubosciomierze i macki Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych pomiar zewnetrzny od 0 mm do 500 mm CMC 2,2 µm pomiar wewnetrzny od 3 mm do 500 mm CMC 3,7 µm Tloustkomery a hmatadla Kalibrace – delka Mereni pomoci koncovych merek vnejsi mereni 0 mm az 500 mm CMC 2,2 µm vnitrni mereni 3 mm az 500 mm CMC 3,7 µm Kp 01-010","search_en":"Thickness gauges and callipers Calibration – length Measurement using parallel gauge blocks external measurement 0 mm to 500 mm CMC 2,2 µm internal measurement 3 mm to 500 mm CMC 3,7 µm Kp 01-010","search_zh":"测厚仪和卡钳 校准 – 长度 使用量块测量 外测量 0 mm 至 500 mm CMC 2,2 µm 内测量 3 mm 至 500 mm CMC 3,7 µm Kp 01-010","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fdca5c6aa199b43a30f1a779","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"14","test_object":"Grubościomierze powłok suchych","test_object_en":"Dry layer thickness gauges","test_object_zh":"干膜测厚仪","test_object_cs":"Tloušťkoměry suchých vrstev","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"powłoki suche","range":"od 0 mm do 40 mm","cmc":"1,4 µm"}],"parameters_en":[{"name":"dry layers","range":"0 mm to 40 mm","cmc":"1,4 µm"}],"parameters_zh":[{"name":"干膜","range":"0 mm 至 40 mm","cmc":"1,4 µm"}],"parameters_cs":[{"name":"suché vrstvy","range":"0 mm až 40 mm","cmc":"1,4 µm"}],"technique":"Pomiar za pomocą wzorca grubości","technique_en":"Measurement using a thickness reference standard","technique_zh":"使用厚度标准测量","technique_cs":"Měření pomocí etalonu tloušťky","techniques":["Pomiar za pomocą wzorca grubości"],"techniques_en":["Measurement using a thickness reference standard"],"techniques_zh":["使用厚度标准测量"],"techniques_cs":["Měření pomocí etalonu tloušťky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\npowłoki suche od 0 mm do 40 mm CMC 1,4 µm\nPomiar za pomocą wzorca grubości","reference":"Kp 01-009","norm_bases":["Kp 01-009"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grubościomierze powłok suchych Wzorcowanie – długość Pomiar za pomocą wzorca grubości powłoki suche od 0 mm do 40 mm CMC 1,4 µm Tloušťkoměry suchých vrstev Kalibrace – délka Měření pomocí etalonu tloušťky suché vrstvy 0 mm až 40 mm CMC 1,4 µm Kp 01-009 Grubosciomierze powlok suchych Wzorcowanie – dlugosc Pomiar za pomoca wzorca grubosci powloki suche od 0 mm do 40 mm CMC 1,4 µm Tloustkomery suchych vrstev Kalibrace – delka Mereni pomoci etalonu tloustky suche vrstvy 0 mm az 40 mm CMC 1,4 µm Kp 01-009","search_en":"Dry layer thickness gauges Calibration – length Measurement using a thickness reference standard dry layers 0 mm to 40 mm CMC 1,4 µm Kp 01-009","search_zh":"干膜测厚仪 校准 – 长度 使用厚度标准测量 干膜 0 mm 至 40 mm CMC 1,4 µm Kp 01-009","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f4ef7bad243bbbafb06561c0","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"15","test_object":"Grubościomierze powłok mokrych","test_object_en":"Wet layer thickness gauges","test_object_zh":"湿膜测厚仪","test_object_cs":"Tloušťkoměry mokrých vrstev","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"powłoki mokre","range":"od 0 mm do 15 mm","cmc":"1 µm"}],"parameters_en":[{"name":"wet layers","range":"0 mm to 15 mm","cmc":"1 µm"}],"parameters_zh":[{"name":"湿膜","range":"0 mm 至 15 mm","cmc":"1 µm"}],"parameters_cs":[{"name":"mokré vrstvy","range":"0 mm až 15 mm","cmc":"1 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\npowłoki mokre od 0 mm do 15 mm CMC 1 µm\nPomiar na długościomierzu","reference":"Kp 01-009","norm_bases":["Kp 01-009"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grubościomierze powłok mokrych Wzorcowanie – długość Pomiar na długościomierzu powłoki mokre od 0 mm do 15 mm CMC 1 µm Tloušťkoměry mokrých vrstev Kalibrace – délka Měření na délkoměru mokré vrstvy 0 mm až 15 mm CMC 1 µm Kp 01-009 Grubosciomierze powlok mokrych Wzorcowanie – dlugosc Pomiar na dlugosciomierzu powloki mokre od 0 mm do 15 mm CMC 1 µm Tloustkomery mokrych vrstev Kalibrace – delka Mereni na delkomeru mokre vrstvy 0 mm az 15 mm CMC 1 µm Kp 01-009","search_en":"Wet layer thickness gauges Calibration – length Measurement on a length gauge wet layers 0 mm to 15 mm CMC 1 µm Kp 01-009","search_zh":"湿膜测厚仪 校准 – 长度 在测长仪上测量 湿膜 0 mm 至 15 mm CMC 1 µm Kp 01-009","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8da461f8fbe51fc5de1ddf6a","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"16","test_object":"Płyty pomiarowe/ płaskość","test_object_en":"Surface plates / flatness","test_object_zh":"平板/ 平面度","test_object_cs":"Příměrné desky/ rovinnost","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"długość do 500 mm","range":"od 0 mm do 5 mm","cmc":"3,5 µm"},{"name":"długość do 1000 mm","range":"od 0 mm do 5 mm","cmc":"6,6 µm"},{"name":"długość do 2000 mm","range":"od 0 mm do 5 mm","cmc":"35 µm"}],"parameters_en":[{"name":"length up to 500 mm","range":"0 mm to 5 mm","cmc":"3,5 µm"},{"name":"length up to 1,000 mm","range":"0 mm to 5 mm","cmc":"6,6 µm"},{"name":"length up to 2,000 mm","range":"0 mm to 5 mm","cmc":"35 µm"}],"parameters_zh":[{"name":"长度不超过 500 mm","range":"0 mm 至 5 mm","cmc":"3,5 µm"},{"name":"长度不超过 1000 mm","range":"0 mm 至 5 mm","cmc":"6,6 µm"},{"name":"长度不超过 2000 mm","range":"0 mm 至 5 mm","cmc":"35 µm"}],"parameters_cs":[{"name":"délka do 500 mm","range":"0 mm až 5 mm","cmc":"3,5 µm"},{"name":"délka do 1000 mm","range":"0 mm až 5 mm","cmc":"6,6 µm"},{"name":"délka do 2000 mm","range":"0 mm až 5 mm","cmc":"35 µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"使用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["使用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\ndługość do 500 mm od 0 mm do 5 mm CMC 3,5 µm\ndługość do 1000 mm od 0 mm do 5 mm CMC 6,6 µm\ndługość do 2000 mm od 0 mm do 5 mm CMC 35 µm\nPomiar za pomocą płytek wzorcowych","reference":"Kp 01-008","norm_bases":["Kp 01-008"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płyty pomiarowe/ płaskość Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych długość do 500 mm od 0 mm do 5 mm CMC 3,5 µm długość do 1000 mm od 0 mm do 5 mm CMC 6,6 µm długość do 2000 mm od 0 mm do 5 mm CMC 35 µm Příměrné desky/ rovinnost Kalibrace – délka Měření pomocí koncových měrek délka do 500 mm 0 mm až 5 mm CMC 3,5 µm délka do 1000 mm 0 mm až 5 mm CMC 6,6 µm délka do 2000 mm 0 mm až 5 mm CMC 35 µm Kp 01-008 Plyty pomiarowe/ plaskosc Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych dlugosc do 500 mm od 0 mm do 5 mm CMC 3,5 µm dlugosc do 1000 mm od 0 mm do 5 mm CMC 6,6 µm dlugosc do 2000 mm od 0 mm do 5 mm CMC 35 µm Primerne desky/ rovinnost Kalibrace – delka Mereni pomoci koncovych merek delka do 500 mm 0 mm az 5 mm CMC 3,5 µm delka do 1000 mm 0 mm az 5 mm CMC 6,6 µm delka do 2000 mm 0 mm az 5 mm CMC 35 µm Kp 01-008","search_en":"Surface plates / flatness Calibration – length Measurement using parallel gauge blocks length up to 500 mm 0 mm to 5 mm CMC 3,5 µm length up to 1,000 mm 0 mm to 5 mm CMC 6,6 µm length up to 2,000 mm 0 mm to 5 mm CMC 35 µm Kp 01-008","search_zh":"平板/ 平面度 校准 – 长度 使用量块测量 长度不超过 500 mm 0 mm 至 5 mm CMC 3,5 µm 长度不超过 1000 mm 0 mm 至 5 mm CMC 6,6 µm 长度不超过 2000 mm 0 mm 至 5 mm CMC 35 µm Kp 01-008","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4f096af2701ff88be4769cad","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"16","test_object":"Liniały krawędziowe/ prostoliniowość","test_object_en":"Surface rules / straightness","test_object_zh":"平尺/ 直线度","test_object_cs":"Příměrná pravítka/ přímost","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"długość do 1000 mm","range":"od 0 mm do 5 mm","cmc":"5,1 µm"},{"name":"długość do 2000 mm","range":"od 0 mm do 5 mm","cmc":"9,5 µm"}],"parameters_en":[{"name":"length up to 1,000 mm","range":"0 mm to 5 mm","cmc":"5,1 µm"},{"name":"length up to 2,000 mm","range":"0 mm to 5 mm","cmc":"9,5 µm"}],"parameters_zh":[{"name":"长度不超过 1000 mm","range":"0 mm 至 5 mm","cmc":"5,1 µm"},{"name":"长度不超过 2000 mm","range":"0 mm 至 5 mm","cmc":"9,5 µm"}],"parameters_cs":[{"name":"délka do 1000 mm","range":"0 mm až 5 mm","cmc":"5,1 µm"},{"name":"délka do 2000 mm","range":"0 mm až 5 mm","cmc":"9,5 µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"使用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["使用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\ndługość do 1000 mm od 0 mm do 5 mm CMC 5,1 µm\ndługość do 2000 mm od 0 mm do 5 mm CMC 9,5 µm\nPomiar za pomocą płytek wzorcowych","reference":"Kp 01-008","norm_bases":["Kp 01-008"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Liniały krawędziowe/ prostoliniowość Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych długość do 1000 mm od 0 mm do 5 mm CMC 5,1 µm długość do 2000 mm od 0 mm do 5 mm CMC 9,5 µm Příměrná pravítka/ přímost Kalibrace – délka Měření pomocí koncových měrek délka do 1000 mm 0 mm až 5 mm CMC 5,1 µm délka do 2000 mm 0 mm až 5 mm CMC 9,5 µm Kp 01-008 Linialy krawedziowe/ prostoliniowosc Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych dlugosc do 1000 mm od 0 mm do 5 mm CMC 5,1 µm dlugosc do 2000 mm od 0 mm do 5 mm CMC 9,5 µm Primerna pravitka/ primost Kalibrace – delka Mereni pomoci koncovych merek delka do 1000 mm 0 mm az 5 mm CMC 5,1 µm delka do 2000 mm 0 mm az 5 mm CMC 9,5 µm Kp 01-008","search_en":"Surface rules / straightness Calibration – length Measurement using parallel gauge blocks length up to 1,000 mm 0 mm to 5 mm CMC 5,1 µm length up to 2,000 mm 0 mm to 5 mm CMC 9,5 µm Kp 01-008","search_zh":"平尺/ 直线度 校准 – 长度 使用量块测量 长度不超过 1000 mm 0 mm 至 5 mm CMC 5,1 µm 长度不超过 2000 mm 0 mm 至 5 mm CMC 9,5 µm Kp 01-008","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"47c8134458cfc2dfb19ee8ff","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"16","test_object":"Liniały nożowe/ prostoliniowość","test_object_en":"Blade rules / straightness","test_object_zh":"刀口尺/ 直线度","test_object_cs":"Nožová pravítka/ přímost","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"długość do 100 mm","range":"od 0 mm do 5 mm","cmc":"2,4 µm"},{"name":"długość do 500 mm","range":"od 0 mm do 5 mm","cmc":"2,8 µm"},{"name":"długość do 1000 mm","range":"od 0 mm do 5 mm","cmc":"5,1 µm"}],"parameters_en":[{"name":"length up to 100 mm","range":"0 mm to 5 mm","cmc":"2,4 µm"},{"name":"length up to 500 mm","range":"0 mm to 5 mm","cmc":"2,8 µm"},{"name":"length up to 1,000 mm","range":"0 mm to 5 mm","cmc":"5,1 µm"}],"parameters_zh":[{"name":"长度不超过 100 mm","range":"0 mm 至 5 mm","cmc":"2,4 µm"},{"name":"长度不超过 500 mm","range":"0 mm 至 5 mm","cmc":"2,8 µm"},{"name":"长度不超过 1000 mm","range":"0 mm 至 5 mm","cmc":"5,1 µm"}],"parameters_cs":[{"name":"délka do 100 mm","range":"0 mm až 5 mm","cmc":"2,4 µm"},{"name":"délka do 500 mm","range":"0 mm až 5 mm","cmc":"2,8 µm"},{"name":"délka do 1000 mm","range":"0 mm až 5 mm","cmc":"5,1 µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"使用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["使用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\ndługość do 100 mm od 0 mm do 5 mm CMC 2,4 µm\ndługość do 500 mm od 0 mm do 5 mm CMC 2,8 µm\ndługość do 1000 mm od 0 mm do 5 mm CMC 5,1 µm\nPomiar za pomocą płytek wzorcowych","reference":"Kp 01-008","norm_bases":["Kp 01-008"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Liniały nożowe/ prostoliniowość Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych długość do 100 mm od 0 mm do 5 mm CMC 2,4 µm długość do 500 mm od 0 mm do 5 mm CMC 2,8 µm długość do 1000 mm od 0 mm do 5 mm CMC 5,1 µm Nožová pravítka/ přímost Kalibrace – délka Měření pomocí koncových měrek délka do 100 mm 0 mm až 5 mm CMC 2,4 µm délka do 500 mm 0 mm až 5 mm CMC 2,8 µm délka do 1000 mm 0 mm až 5 mm CMC 5,1 µm Kp 01-008 Linialy nozowe/ prostoliniowosc Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych dlugosc do 100 mm od 0 mm do 5 mm CMC 2,4 µm dlugosc do 500 mm od 0 mm do 5 mm CMC 2,8 µm dlugosc do 1000 mm od 0 mm do 5 mm CMC 5,1 µm Nozova pravitka/ primost Kalibrace – delka Mereni pomoci koncovych merek delka do 100 mm 0 mm az 5 mm CMC 2,4 µm delka do 500 mm 0 mm az 5 mm CMC 2,8 µm delka do 1000 mm 0 mm az 5 mm CMC 5,1 µm Kp 01-008","search_en":"Blade rules / straightness Calibration – length Measurement using parallel gauge blocks length up to 100 mm 0 mm to 5 mm CMC 2,4 µm length up to 500 mm 0 mm to 5 mm CMC 2,8 µm length up to 1,000 mm 0 mm to 5 mm CMC 5,1 µm Kp 01-008","search_zh":"刀口尺/ 直线度 校准 – 长度 使用量块测量 长度不超过 100 mm 0 mm 至 5 mm CMC 2,4 µm 长度不超过 500 mm 0 mm 至 5 mm CMC 2,8 µm 长度不超过 1000 mm 0 mm 至 5 mm CMC 5,1 µm Kp 01-008","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bc01116e18101a309219af82","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"17","test_object":"Odległościomierze kołowe","test_object_en":"Roller length gauges","test_object_zh":"滚轮测距仪","test_object_cs":"Odvalovací měřidla délky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 300 m","cmc":"(0,2·L+ 10) mm"}],"parameters_en":[{"name":"","range":"0 m to 300 m","cmc":"(0,2·L+ 10) mm"}],"parameters_zh":[{"name":"","range":"0 m 至 300 m","cmc":"(0,2·L+ 10) mm"}],"parameters_cs":[{"name":"","range":"0 m až 300 m","cmc":"(0,2·L+ 10) mm"}],"technique":"Pomiar za pomocą specjalnego urządzenia pomiarowego","technique_en":"Measurement using special measuring equipment","technique_zh":"使用专用测量装置测量","technique_cs":"Měření pomocí speciálního měřícího zařízení","techniques":["Pomiar za pomocą specjalnego urządzenia pomiarowego"],"techniques_en":["Measurement using special measuring equipment"],"techniques_zh":["使用专用测量装置测量"],"techniques_cs":["Měření pomocí speciálního měřícího zařízení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 300 m CMC (0,2·L+ 10) mm\nPomiar za pomocą specjalnego urządzenia pomiarowego","reference":"Kp 01-014","norm_bases":["Kp 01-014"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Odległościomierze kołowe Wzorcowanie – długość Pomiar za pomocą specjalnego urządzenia pomiarowego od 0 m do 300 m CMC (0,2·L+ 10) mm Odvalovací měřidla délky Kalibrace – délka Měření pomocí speciálního měřícího zařízení 0 m až 300 m CMC (0,2·L+ 10) mm Kp 01-014 Odleglosciomierze kolowe Wzorcowanie – dlugosc Pomiar za pomoca specjalnego urzadzenia pomiarowego od 0 m do 300 m CMC (0,2·L+ 10) mm Odvalovaci meridla delky Kalibrace – delka Mereni pomoci specialniho mericiho zarizeni 0 m az 300 m CMC (0,2·L+ 10) mm Kp 01-014","search_en":"Roller length gauges Calibration – length Measurement using special measuring equipment 0 m to 300 m CMC (0,2·L+ 10) mm Kp 01-014","search_zh":"滚轮测距仪 校准 – 长度 使用专用测量装置测量 0 m 至 300 m CMC (0,2·L+ 10) mm Kp 01-014","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"390bb9a2e673684bb41580c7","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"18","test_object":"Dalmierze laserowe","test_object_en":"Laser distance meters","test_object_zh":"激光测距仪","test_object_cs":"Laserové měřiče vzdálenosti","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,5 m do 8 m","cmc":"0,3 mm"}],"parameters_en":[{"name":"","range":"0,5 m to 8 m","cmc":"0,3 mm"}],"parameters_zh":[{"name":"","range":"0,5 m 至 8 m","cmc":"0,3 mm"}],"parameters_cs":[{"name":"","range":"0,5 m až 8 m","cmc":"0,3 mm"}],"technique":"Porównanie z wzorcowym torem pomiarowym","technique_en":"Comparison with a reference track","technique_zh":"与标准测量轨道比较","technique_cs":"Porovnání s etalonovou tratí","techniques":["Porównanie z wzorcowym torem pomiarowym"],"techniques_en":["Comparison with a reference track"],"techniques_zh":["与标准测量轨道比较"],"techniques_cs":["Porovnání s etalonovou tratí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,5 m do 8 m CMC 0,3 mm\nPorównanie z wzorcowym torem pomiarowym","reference":"Kp 01-014","norm_bases":["Kp 01-014"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Dalmierze laserowe Wzorcowanie – długość Porównanie z wzorcowym torem pomiarowym od 0,5 m do 8 m CMC 0,3 mm Laserové měřiče vzdálenosti Kalibrace – délka Porovnání s etalonovou tratí 0,5 m až 8 m CMC 0,3 mm Kp 01-014 Dalmierze laserowe Wzorcowanie – dlugosc Porownanie z wzorcowym torem pomiarowym od 0,5 m do 8 m CMC 0,3 mm Laserove merice vzdalenosti Kalibrace – delka Porovnani s etalonovou trati 0,5 m az 8 m CMC 0,3 mm Kp 01-014","search_en":"Laser distance meters Calibration – length Comparison with a reference track 0,5 m to 8 m CMC 0,3 mm Kp 01-014","search_zh":"激光测距仪 校准 – 长度 与标准测量轨道比较 0,5 m 至 8 m CMC 0,3 mm Kp 01-014","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5bb181ecc8bfc495ffb2729d","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"19","test_object":"Łaty niwelacyjne","test_object_en":"Levelling rods","test_object_zh":"水准尺","test_object_cs":"Nivelační latě","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 7 m","cmc":"0,3 mm"}],"parameters_en":[{"name":"","range":"0 m to 7 m","cmc":"0,3 mm"}],"parameters_zh":[{"name":"","range":"0 m 至 7 m","cmc":"0,3 mm"}],"parameters_cs":[{"name":"","range":"0 m až 7 m","cmc":"0,3 mm"}],"technique":"Porównanie z wzorcowym torem pomiarowym","technique_en":"Comparison with a reference track","technique_zh":"与标准测量轨道比较","technique_cs":"Porovnání s etalonovou tratí","techniques":["Porównanie z wzorcowym torem pomiarowym"],"techniques_en":["Comparison with a reference track"],"techniques_zh":["与标准测量轨道比较"],"techniques_cs":["Porovnání s etalonovou tratí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 7 m CMC 0,3 mm\nPorównanie z wzorcowym torem pomiarowym","reference":"Kp 01-014","norm_bases":["Kp 01-014"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Łaty niwelacyjne Wzorcowanie – długość Porównanie z wzorcowym torem pomiarowym od 0 m do 7 m CMC 0,3 mm Nivelační latě Kalibrace – délka Porovnání s etalonovou tratí 0 m až 7 m CMC 0,3 mm Kp 01-014 Laty niwelacyjne Wzorcowanie – dlugosc Porownanie z wzorcowym torem pomiarowym od 0 m do 7 m CMC 0,3 mm Nivelacni late Kalibrace – delka Porovnani s etalonovou trati 0 m az 7 m CMC 0,3 mm Kp 01-014","search_en":"Levelling rods Calibration – length Comparison with a reference track 0 m to 7 m CMC 0,3 mm Kp 01-014","search_zh":"水准尺 校准 – 长度 与标准测量轨道比较 0 m 至 7 m CMC 0,3 mm Kp 01-014","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"09fae4ba31cc44809a1d0d3c","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"20","test_object":"Teleskopowe przyrządy do pomiaru długości","test_object_en":"Telescopic length gauges","test_object_zh":"伸缩式测长尺","test_object_cs":"Teleskopická měřidla délky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 7 m","cmc":"0,3 mm"}],"parameters_en":[{"name":"","range":"0 m to 7 m","cmc":"0,3 mm"}],"parameters_zh":[{"name":"","range":"0 m 至 7 m","cmc":"0,3 mm"}],"parameters_cs":[{"name":"","range":"0 m až 7 m","cmc":"0,3 mm"}],"technique":"Porównanie z wzorcowym torem pomiarowym","technique_en":"Comparison with a reference track","technique_zh":"与标准测量轨道比较","technique_cs":"Porovnání s etalonovou tratí","techniques":["Porównanie z wzorcowym torem pomiarowym"],"techniques_en":["Comparison with a reference track"],"techniques_zh":["与标准测量轨道比较"],"techniques_cs":["Porovnání s etalonovou tratí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 7 m CMC 0,3 mm\nPorównanie z wzorcowym torem pomiarowym","reference":"Kp 01-014","norm_bases":["Kp 01-014"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Teleskopowe przyrządy do pomiaru długości Wzorcowanie – długość Porównanie z wzorcowym torem pomiarowym od 0 m do 7 m CMC 0,3 mm Teleskopická měřidla délky Kalibrace – délka Porovnání s etalonovou tratí 0 m až 7 m CMC 0,3 mm Kp 01-014 Teleskopowe przyrzady do pomiaru dlugosci Wzorcowanie – dlugosc Porownanie z wzorcowym torem pomiarowym od 0 m do 7 m CMC 0,3 mm Teleskopicka meridla delky Kalibrace – delka Porovnani s etalonovou trati 0 m az 7 m CMC 0,3 mm Kp 01-014","search_en":"Telescopic length gauges Calibration – length Comparison with a reference track 0 m to 7 m CMC 0,3 mm Kp 01-014","search_zh":"伸缩式测长尺 校准 – 长度 与标准测量轨道比较 0 m 至 7 m CMC 0,3 mm Kp 01-014","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"46c946b1f8af99a4b9c75efb","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"21","test_object":"Wzorniki spoin/ parametry spoiny","test_object_en":"Weld gauges / weld parameters","test_object_zh":"焊缝规/ 焊缝参数","test_object_cs":"Měrky na svary/ parametry svaru","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 20 mm","cmc":"10 µm"}],"parameters_en":[{"name":"","range":"0 mm to 20 mm","cmc":"10 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 20 mm","cmc":"10 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 20 mm","cmc":"10 µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"使用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["使用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 20 mm CMC 10 µm\nPomiar za pomocą płytek wzorcowych","reference":"Kp 01-015","norm_bases":["Kp 01-015"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorniki spoin/ parametry spoiny Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 0 mm do 20 mm CMC 10 µm Měrky na svary/ parametry svaru Kalibrace – délka Měření pomocí koncových měrek 0 mm až 20 mm CMC 10 µm Kp 01-015 Wzorniki spoin/ parametry spoiny Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 0 mm do 20 mm CMC 10 µm Merky na svary/ parametry svaru Kalibrace – delka Mereni pomoci koncovych merek 0 mm az 20 mm CMC 10 µm Kp 01-015","search_en":"Weld gauges / weld parameters Calibration – length Measurement using parallel gauge blocks 0 mm to 20 mm CMC 10 µm Kp 01-015","search_zh":"焊缝规/ 焊缝参数 校准 – 长度 使用量块测量 0 mm 至 20 mm CMC 10 µm Kp 01-015","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9314a857fba210dedf6eb8c3","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"22","test_object":"Kątowniki 90°/ prostopadłość","test_object_en":"90° angles / perpendicularity","test_object_zh":"90° 角尺/ 垂直度","test_object_cs":"Úhelníky 90°/ kolmost","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"dłuższy bok do 100 mm","range":"od 0 mm do 5 mm","cmc":"2,8 µm"},{"name":"dłuższy bok do 1000 mm","range":"od 0 mm do 5 mm","cmc":"(8·L+ 6,5) µm"}],"parameters_en":[{"name":"longer side up to 100 mm","range":"0 mm to 5 mm","cmc":"2,8 µm"},{"name":"longer side up to 1,000 mm","range":"0 mm to 5 mm","cmc":"(8·L+ 6,5) µm"}],"parameters_zh":[{"name":"较长边不超过 100 mm","range":"0 mm 至 5 mm","cmc":"2,8 µm"},{"name":"较长边不超过 1000 mm","range":"0 mm 至 5 mm","cmc":"(8·L+ 6,5) µm"}],"parameters_cs":[{"name":"delší strana do 100 mm","range":"0 mm až 5 mm","cmc":"2,8 µm"},{"name":"delší strana do 1000 mm","range":"0 mm až 5 mm","cmc":"(8·L+ 6,5) µm"}],"technique":"Pomiar za pomocą walca prostopadłości i płytek wzorcowych","technique_en":"Measurement using a measuring cylinder of squareness and parallel gauge blocks","technique_zh":"使用直角度圆柱和量块测量","technique_cs":"Měření pomoci válce kolmosti a koncových měrek","techniques":["Pomiar za pomocą walca prostopadłości i płytek wzorcowych"],"techniques_en":["Measurement using a measuring cylinder of squareness and parallel gauge blocks"],"techniques_zh":["使用直角度圆柱和量块测量"],"techniques_cs":["Měření pomoci válce kolmosti a koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\ndłuższy bok do 100 mm od 0 mm do 5 mm CMC 2,8 µm\ndłuższy bok do 1000 mm od 0 mm do 5 mm CMC (8·L+ 6,5) µm\nPomiar za pomocą walca prostopadłości i płytek wzorcowych","reference":"Kp 02-001","norm_bases":["Kp 02-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątowniki 90°/ prostopadłość Wzorcowanie – długość Pomiar za pomocą walca prostopadłości i płytek wzorcowych dłuższy bok do 100 mm od 0 mm do 5 mm CMC 2,8 µm dłuższy bok do 1000 mm od 0 mm do 5 mm CMC (8·L+ 6,5) µm Úhelníky 90°/ kolmost Kalibrace – délka Měření pomoci válce kolmosti a koncových měrek delší strana do 100 mm 0 mm až 5 mm CMC 2,8 µm delší strana do 1000 mm 0 mm až 5 mm CMC (8·L+ 6,5) µm Kp 02-001 Katowniki 90°/ prostopadlosc Wzorcowanie – dlugosc Pomiar za pomoca walca prostopadlosci i plytek wzorcowych dluzszy bok do 100 mm od 0 mm do 5 mm CMC 2,8 µm dluzszy bok do 1000 mm od 0 mm do 5 mm CMC (8·L+ 6,5) µm Uhelniky 90°/ kolmost Kalibrace – delka Mereni pomoci valce kolmosti a koncovych merek delsi strana do 100 mm 0 mm az 5 mm CMC 2,8 µm delsi strana do 1000 mm 0 mm az 5 mm CMC (8·L+ 6,5) µm Kp 02-001","search_en":"90° angles / perpendicularity Calibration – length Measurement using a measuring cylinder of squareness and parallel gauge blocks longer side up to 100 mm 0 mm to 5 mm CMC 2,8 µm longer side up to 1,000 mm 0 mm to 5 mm CMC (8·L+ 6,5) µm Kp 02-001","search_zh":"90° 角尺/ 垂直度 校准 – 长度 使用直角度圆柱和量块测量 较长边不超过 100 mm 0 mm 至 5 mm CMC 2,8 µm 较长边不超过 1000 mm 0 mm 至 5 mm CMC (8·L+ 6,5) µm Kp 02-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"38de246e3e69b6f7a78213c7","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"22","test_object":"Kątowniki 90°/ prostoliniowość","test_object_en":"90° angles / straightness","test_object_zh":"90° 角尺/ 直线度","test_object_cs":"Úhelníky 90°/ přímost","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"dłuższy bok do 100 mm","range":"od 0 mm do 5 mm","cmc":"2,2 µm"},{"name":"dłuższy bok do 1000 mm","range":"od 0 mm do 5 mm","cmc":"5,1 µm"}],"parameters_en":[{"name":"longer side up to 100 mm","range":"0 mm to 5 mm","cmc":"2,2 µm"},{"name":"longer side up to 1,000 mm","range":"0 mm to 5 mm","cmc":"5,1 µm"}],"parameters_zh":[{"name":"较长边不超过 100 mm","range":"0 mm 至 5 mm","cmc":"2,2 µm"},{"name":"较长边不超过 1000 mm","range":"0 mm 至 5 mm","cmc":"5,1 µm"}],"parameters_cs":[{"name":"delší strana do 100 mm","range":"0 mm až 5 mm","cmc":"2,2 µm"},{"name":"delší strana do 1000 mm","range":"0 mm až 5 mm","cmc":"5,1 µm"}],"technique":"Pomiar za pomocą walca prostopadłości i płytek wzorcowych","technique_en":"Measurement using a measuring cylinder of squareness and parallel gauge blocks","technique_zh":"使用直角度圆柱和量块测量","technique_cs":"Měření pomoci válce kolmosti a koncových měrek","techniques":["Pomiar za pomocą walca prostopadłości i płytek wzorcowych"],"techniques_en":["Measurement using a measuring cylinder of squareness and parallel gauge blocks"],"techniques_zh":["使用直角度圆柱和量块测量"],"techniques_cs":["Měření pomoci válce kolmosti a koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\ndłuższy bok do 100 mm od 0 mm do 5 mm CMC 2,2 µm\ndłuższy bok do 1000 mm od 0 mm do 5 mm CMC 5,1 µm\nPomiar za pomocą walca prostopadłości i płytek wzorcowych","reference":"Kp 02-001","norm_bases":["Kp 02-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątowniki 90°/ prostoliniowość Wzorcowanie – długość Pomiar za pomocą walca prostopadłości i płytek wzorcowych dłuższy bok do 100 mm od 0 mm do 5 mm CMC 2,2 µm dłuższy bok do 1000 mm od 0 mm do 5 mm CMC 5,1 µm Úhelníky 90°/ přímost Kalibrace – délka Měření pomoci válce kolmosti a koncových měrek delší strana do 100 mm 0 mm až 5 mm CMC 2,2 µm delší strana do 1000 mm 0 mm až 5 mm CMC 5,1 µm Kp 02-001 Katowniki 90°/ prostoliniowosc Wzorcowanie – dlugosc Pomiar za pomoca walca prostopadlosci i plytek wzorcowych dluzszy bok do 100 mm od 0 mm do 5 mm CMC 2,2 µm dluzszy bok do 1000 mm od 0 mm do 5 mm CMC 5,1 µm Uhelniky 90°/ primost Kalibrace – delka Mereni pomoci valce kolmosti a koncovych merek delsi strana do 100 mm 0 mm az 5 mm CMC 2,2 µm delsi strana do 1000 mm 0 mm az 5 mm CMC 5,1 µm Kp 02-001","search_en":"90° angles / straightness Calibration – length Measurement using a measuring cylinder of squareness and parallel gauge blocks longer side up to 100 mm 0 mm to 5 mm CMC 2,2 µm longer side up to 1,000 mm 0 mm to 5 mm CMC 5,1 µm Kp 02-001","search_zh":"90° 角尺/ 直线度 校准 – 长度 使用直角度圆柱和量块测量 较长边不超过 100 mm 0 mm 至 5 mm CMC 2,2 µm 较长边不超过 1000 mm 0 mm 至 5 mm CMC 5,1 µm Kp 02-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e9d21d6fb377145ed5175b42","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"22","test_object":"Kątowniki 90°/ równoległość","test_object_en":"90° angles / parallelity","test_object_zh":"90° 角尺/ 平行度","test_object_cs":"Úhelníky 90°/ rovnoběžnost","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 5 mm","cmc":"2,9 µm"}],"parameters_en":[{"name":"","range":"0 mm to 5 mm","cmc":"2,9 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 5 mm","cmc":"2,9 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 5 mm","cmc":"2,9 µm"}],"technique":"Pomiar za pomocą walca prostopadłości i płytek wzorcowych","technique_en":"Measurement using a measuring cylinder of squareness and parallel gauge blocks","technique_zh":"使用直角度圆柱和量块测量","technique_cs":"Měření pomoci válce kolmosti a koncových měrek","techniques":["Pomiar za pomocą walca prostopadłości i płytek wzorcowych"],"techniques_en":["Measurement using a measuring cylinder of squareness and parallel gauge blocks"],"techniques_zh":["使用直角度圆柱和量块测量"],"techniques_cs":["Měření pomoci válce kolmosti a koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 5 mm CMC 2,9 µm\nPomiar za pomocą walca prostopadłości i płytek wzorcowych","reference":"Kp 02-001","norm_bases":["Kp 02-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątowniki 90°/ równoległość Wzorcowanie – długość Pomiar za pomocą walca prostopadłości i płytek wzorcowych od 0 mm do 5 mm CMC 2,9 µm Úhelníky 90°/ rovnoběžnost Kalibrace – délka Měření pomoci válce kolmosti a koncových měrek 0 mm až 5 mm CMC 2,9 µm Kp 02-001 Katowniki 90°/ rownoleglosc Wzorcowanie – dlugosc Pomiar za pomoca walca prostopadlosci i plytek wzorcowych od 0 mm do 5 mm CMC 2,9 µm Uhelniky 90°/ rovnobeznost Kalibrace – delka Mereni pomoci valce kolmosti a koncovych merek 0 mm az 5 mm CMC 2,9 µm Kp 02-001","search_en":"90° angles / parallelity Calibration – length Measurement using a measuring cylinder of squareness and parallel gauge blocks 0 mm to 5 mm CMC 2,9 µm Kp 02-001","search_zh":"90° 角尺/ 平行度 校准 – 长度 使用直角度圆柱和量块测量 0 mm 至 5 mm CMC 2,9 µm Kp 02-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"79ecbdc2fccc1cd1b8765eec","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"23","test_object":"Przyrządy pomiarowe i wzorniki kształtowe","test_object_en":"Measuring jigs and profile gauges","test_object_zh":"测量夹具和样板量规","test_object_cs":"Měřící přípravky a tvarová měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,5 µm"},{"name":"","range":"od 100 mm do 500 mm","cmc":"1 µm"},{"name":"","range":"od 950 mm do 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"},{"name":"","range":"100 mm to 500 mm","cmc":"1 µm"},{"name":"","range":"950 mm to 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,5 µm"},{"name":"","range":"100 mm 至 500 mm","cmc":"1 µm"},{"name":"","range":"950 mm 至 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,5 µm"},{"name":"","range":"100 mm až 500 mm","cmc":"1 µm"},{"name":"","range":"950 mm až 2800 mm","cmc":"(3,5·L+ 0,6) µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 100 mm CMC 0,5 µm\nod 100 mm do 500 mm CMC 1 µm\nod 950 mm do 2800 mm CMC (3,5·L+ 0,6) µm\nPomiar na długościomierzu","reference":"Kp 01-017","norm_bases":["Kp 01-017"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy pomiarowe i wzorniki kształtowe Wzorcowanie – długość Pomiar na długościomierzu od 0 mm do 100 mm CMC 0,5 µm od 100 mm do 500 mm CMC 1 µm od 950 mm do 2800 mm CMC (3,5·L+ 0,6) µm Měřící přípravky a tvarová měřidla Kalibrace – délka Měření na délkoměru 0 mm až 100 mm CMC 0,5 µm 100 mm až 500 mm CMC 1 µm 950 mm až 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-017 Przyrzady pomiarowe i wzorniki ksztaltowe Wzorcowanie – dlugosc Pomiar na dlugosciomierzu od 0 mm do 100 mm CMC 0,5 µm od 100 mm do 500 mm CMC 1 µm od 950 mm do 2800 mm CMC (3,5·L+ 0,6) µm Merici pripravky a tvarova meridla Kalibrace – delka Mereni na delkomeru 0 mm az 100 mm CMC 0,5 µm 100 mm az 500 mm CMC 1 µm 950 mm az 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-017","search_en":"Measuring jigs and profile gauges Calibration – length Measurement on a length gauge 0 mm to 100 mm CMC 0,5 µm 100 mm to 500 mm CMC 1 µm 950 mm to 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-017","search_zh":"测量夹具和样板量规 校准 – 长度 在测长仪上测量 0 mm 至 100 mm CMC 0,5 µm 100 mm 至 500 mm CMC 1 µm 950 mm 至 2800 mm CMC (3,5·L+ 0,6) µm Kp 01-017","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eae654f468e0cb803e0a57a0","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"23","test_object":"Przyrządy pomiarowe i wzorniki kształtowe","test_object_en":"Measuring jigs and profile gauges","test_object_zh":"测量夹具和样板量规","test_object_cs":"Měřící přípravky a tvarová měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 500 mm do 950 mm","cmc":"2 µm"}],"parameters_en":[{"name":"","range":"500 mm to 950 mm","cmc":"2 µm"}],"parameters_zh":[{"name":"","range":"500 mm 至 950 mm","cmc":"2 µm"}],"parameters_cs":[{"name":"","range":"500 mm až 950 mm","cmc":"2 µm"}],"technique":"Pomiar na liniowym wysokościomierzu","technique_en":"Measurement on a linear height gauge","technique_zh":"在线性高度尺上测量","technique_cs":"Měření na lineárním výškoměru","techniques":["Pomiar na liniowym wysokościomierzu"],"techniques_en":["Measurement on a linear height gauge"],"techniques_zh":["在线性高度尺上测量"],"techniques_cs":["Měření na lineárním výškoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 500 mm do 950 mm CMC 2 µm\nPomiar na liniowym wysokościomierzu","reference":"Kp 01-017","norm_bases":["Kp 01-017"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy pomiarowe i wzorniki kształtowe Wzorcowanie – długość Pomiar na liniowym wysokościomierzu od 500 mm do 950 mm CMC 2 µm Měřící přípravky a tvarová měřidla Kalibrace – délka Měření na lineárním výškoměru 500 mm až 950 mm CMC 2 µm Kp 01-017 Przyrzady pomiarowe i wzorniki ksztaltowe Wzorcowanie – dlugosc Pomiar na liniowym wysokosciomierzu od 500 mm do 950 mm CMC 2 µm Merici pripravky a tvarova meridla Kalibrace – delka Mereni na linearnim vyskomeru 500 mm az 950 mm CMC 2 µm Kp 01-017","search_en":"Measuring jigs and profile gauges Calibration – length Measurement on a linear height gauge 500 mm to 950 mm CMC 2 µm Kp 01-017","search_zh":"测量夹具和样板量规 校准 – 长度 在线性高度尺上测量 500 mm 至 950 mm CMC 2 µm Kp 01-017","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c51d892efa7044f1b9e430f","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"24","test_object":"Przyrządy pomiarowe i wzorniki kształtowe","test_object_en":"Measuring jigs and profile gauges","test_object_zh":"测量夹具和样板量规","test_object_cs":"Měřící přípravky a tvarová měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"2 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"2 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"2 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"2 µm"}],"technique":"Pomiar mikrometrem","technique_en":"Measurement using a micrometer","technique_zh":"用千分尺测量","technique_cs":"Měření mikrometrem","techniques":["Pomiar mikrometrem"],"techniques_en":["Measurement using a micrometer"],"techniques_zh":["用千分尺测量"],"techniques_cs":["Měření mikrometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 2 µm\nPomiar mikrometrem","reference":"Kp 01-017","norm_bases":["Kp 01-017"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy pomiarowe i wzorniki kształtowe Wzorcowanie – długość Pomiar mikrometrem od 0 mm do 100 mm CMC 2 µm Měřící přípravky a tvarová měřidla Kalibrace – délka Měření mikrometrem 0 mm až 100 mm CMC 2 µm Kp 01-017 Przyrzady pomiarowe i wzorniki ksztaltowe Wzorcowanie – dlugosc Pomiar mikrometrem od 0 mm do 100 mm CMC 2 µm Merici pripravky a tvarova meridla Kalibrace – delka Mereni mikrometrem 0 mm az 100 mm CMC 2 µm Kp 01-017","search_en":"Measuring jigs and profile gauges Calibration – length Measurement using a micrometer 0 mm to 100 mm CMC 2 µm Kp 01-017","search_zh":"测量夹具和样板量规 校准 – 长度 用千分尺测量 0 mm 至 100 mm CMC 2 µm Kp 01-017","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"37d591d9235e899f24ad870f","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"24","test_object":"Przyrządy pomiarowe i wzorniki kształtowe","test_object_en":"Measuring jigs and profile gauges","test_object_zh":"测量夹具和样板量规","test_object_cs":"Měřící přípravky a tvarová měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 100 mm do 300 mm","cmc":"12 µm"}],"parameters_en":[{"name":"","range":"100 mm to 300 mm","cmc":"12 µm"}],"parameters_zh":[{"name":"","range":"100 mm 至 300 mm","cmc":"12 µm"}],"parameters_cs":[{"name":"","range":"100 mm až 300 mm","cmc":"12 µm"}],"technique":"Pomiar suwmiarką","technique_en":"Measurement with a slide gauge","technique_zh":"用游标卡尺测量","technique_cs":"Měření posuvným měřítkem","techniques":["Pomiar suwmiarką"],"techniques_en":["Measurement with a slide gauge"],"techniques_zh":["用游标卡尺测量"],"techniques_cs":["Měření posuvným měřítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 100 mm do 300 mm CMC 12 µm\nPomiar suwmiarką","reference":"Kp 01-017","norm_bases":["Kp 01-017"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy pomiarowe i wzorniki kształtowe Wzorcowanie – długość Pomiar suwmiarką od 100 mm do 300 mm CMC 12 µm Měřící přípravky a tvarová měřidla Kalibrace – délka Měření posuvným měřítkem 100 mm až 300 mm CMC 12 µm Kp 01-017 Przyrzady pomiarowe i wzorniki ksztaltowe Wzorcowanie – dlugosc Pomiar suwmiarka od 100 mm do 300 mm CMC 12 µm Merici pripravky a tvarova meridla Kalibrace – delka Mereni posuvnym meritkem 100 mm az 300 mm CMC 12 µm Kp 01-017","search_en":"Measuring jigs and profile gauges Calibration – length Measurement with a slide gauge 100 mm to 300 mm CMC 12 µm Kp 01-017","search_zh":"测量夹具和样板量规 校准 – 长度 用游标卡尺测量 100 mm 至 300 mm CMC 12 µm Kp 01-017","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"339aa814c772873f05f0a9e9","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"24","test_object":"Przyrządy pomiarowe i wzorniki kształtowe","test_object_en":"Measuring jigs and profile gauges","test_object_zh":"测量夹具和样板量规","test_object_cs":"Měřící přípravky a tvarová měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 300 mm do 2000 mm","cmc":"15 µm"}],"parameters_en":[{"name":"","range":"300 mm to 2000 mm","cmc":"15 µm"}],"parameters_zh":[{"name":"","range":"300 mm 至 2000 mm","cmc":"15 µm"}],"parameters_cs":[{"name":"","range":"300 mm až 2000 mm","cmc":"15 µm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 300 mm do 2000 mm CMC 15 µm\nPorównanie z płytkami wzorcowymi","reference":"Kp 01-017","norm_bases":["Kp 01-017"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy pomiarowe i wzorniki kształtowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 300 mm do 2000 mm CMC 15 µm Měřící přípravky a tvarová měřidla Kalibrace – délka Porovnání s koncovými měrkami 300 mm až 2000 mm CMC 15 µm Kp 01-017 Przyrzady pomiarowe i wzorniki ksztaltowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 300 mm do 2000 mm CMC 15 µm Merici pripravky a tvarova meridla Kalibrace – delka Porovnani s koncovymi merkami 300 mm az 2000 mm CMC 15 µm Kp 01-017","search_en":"Measuring jigs and profile gauges Calibration – length Comparison with parallel gauge blocks 300 mm to 2000 mm CMC 15 µm Kp 01-017","search_zh":"测量夹具和样板量规 校准 – 长度 与量块比较 300 mm 至 2000 mm CMC 15 µm Kp 01-017","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c94a0007068a30f208f31954","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"24","test_object":"Przyrządy pomiarowe i wzorniki kształtowe","test_object_en":"Measuring jigs and profile gauges","test_object_zh":"测量夹具和样板量规","test_object_cs":"Měřící přípravky a tvarová měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 2 m do 10 m","cmc":"0,5 mm"}],"parameters_en":[{"name":"","range":"2 m to 10 m","cmc":"0,5 mm"}],"parameters_zh":[{"name":"","range":"2 m 至 10 m","cmc":"0,5 mm"}],"parameters_cs":[{"name":"","range":"2 m až 10 m","cmc":"0,5 mm"}],"technique":"Pomiar taśmą wzorcową","technique_en":"Measurement by a reference tape measure","technique_zh":"用标准卷尺测量","technique_cs":"Měření etalonovým pásmem","techniques":["Pomiar taśmą wzorcową"],"techniques_en":["Measurement by a reference tape measure"],"techniques_zh":["用标准卷尺测量"],"techniques_cs":["Měření etalonovým pásmem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 2 m do 10 m CMC 0,5 mm\nPomiar taśmą wzorcową","reference":"Kp 01-017","norm_bases":["Kp 01-017"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy pomiarowe i wzorniki kształtowe Wzorcowanie – długość Pomiar taśmą wzorcową od 2 m do 10 m CMC 0,5 mm Měřící přípravky a tvarová měřidla Kalibrace – délka Měření etalonovým pásmem 2 m až 10 m CMC 0,5 mm Kp 01-017 Przyrzady pomiarowe i wzorniki ksztaltowe Wzorcowanie – dlugosc Pomiar tasma wzorcowa od 2 m do 10 m CMC 0,5 mm Merici pripravky a tvarova meridla Kalibrace – delka Mereni etalonovym pasmem 2 m az 10 m CMC 0,5 mm Kp 01-017","search_en":"Measuring jigs and profile gauges Calibration – length Measurement by a reference tape measure 2 m to 10 m CMC 0,5 mm Kp 01-017","search_zh":"测量夹具和样板量规 校准 – 长度 用标准卷尺测量 2 m 至 10 m CMC 0,5 mm Kp 01-017","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c168669bd9e1bd902b4bc40","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"25","test_object":"Długościomierze","test_object_en":"Length gauges","test_object_zh":"测长仪","test_object_cs":"Délkoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"(1·L+ 0,14) µm"},{"name":"","range":"od 1000 mm do 2800 mm","cmc":"(2·L+ 0,17) µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"(1·L+ 0,14) µm"},{"name":"","range":"1000 mm to 2800 mm","cmc":"(2·L+ 0,17) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(1·L+ 0,14) µm"},{"name":"","range":"1000 mm 至 2800 mm","cmc":"(2·L+ 0,17) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"(1·L+ 0,14) µm"},{"name":"","range":"1000 mm až 2800 mm","cmc":"(2·L+ 0,17) µm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 1000 mm CMC (1·L+ 0,14) µm\nod 1000 mm do 2800 mm CMC (2·L+ 0,17) µm\nPorównanie z płytkami wzorcowymi","reference":"Kp 01-011","norm_bases":["Kp 01-011"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długościomierze Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 1000 mm CMC (1·L+ 0,14) µm od 1000 mm do 2800 mm CMC (2·L+ 0,17) µm Délkoměry Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 1000 mm CMC (1·L+ 0,14) µm 1000 mm až 2800 mm CMC (2·L+ 0,17) µm Kp 01-011 Dlugosciomierze Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 1000 mm CMC (1·L+ 0,14) µm od 1000 mm do 2800 mm CMC (2·L+ 0,17) µm Delkomery Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 1000 mm CMC (1·L+ 0,14) µm 1000 mm az 2800 mm CMC (2·L+ 0,17) µm Kp 01-011","search_en":"Length gauges Calibration – length Comparison with parallel gauge blocks 0 mm to 1000 mm CMC (1·L+ 0,14) µm 1000 mm to 2800 mm CMC (2·L+ 0,17) µm Kp 01-011","search_zh":"测长仪 校准 – 长度 与量块比较 0 mm 至 1000 mm CMC (1·L+ 0,14) µm 1000 mm 至 2800 mm CMC (2·L+ 0,17) µm Kp 01-011","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4831b2d87c16b5cdbe32a120","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"26","test_object":"Mikroskopy pomiarowe, projektory profilowe i współrzędnościowe maszyny pomiarowe","test_object_en":"Measuring microscopes, profile projectors and coordinate measuring machines","test_object_zh":"测量显微镜、轮廓投影仪和坐标测量机","test_object_cs":"Měřící mikroskopy, profilprojektory a souřadnicové měřicí stroje","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 500 mm","cmc":"(1·L+ 0,14) µm"},{"name":"","range":"od 500 mm do 2800 mm","cmc":"(2,2·L+ 0,17) µm"}],"parameters_en":[{"name":"","range":"0 mm to 500 mm","cmc":"(1·L+ 0,14) µm"},{"name":"","range":"500 mm to 2800 mm","cmc":"(2,2·L+ 0,17) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 500 mm","cmc":"(1·L+ 0,14) µm"},{"name":"","range":"500 mm 至 2800 mm","cmc":"(2,2·L+ 0,17) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 500 mm","cmc":"(1·L+ 0,14) µm"},{"name":"","range":"500 mm až 2800 mm","cmc":"(2,2·L+ 0,17) µm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 500 mm CMC (1·L+ 0,14) µm\nod 500 mm do 2800 mm CMC (2,2·L+ 0,17) µm\nPorównanie z płytkami wzorcowymi","reference":"Kp 01-019","norm_bases":["Kp 01-019"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mikroskopy pomiarowe, projektory profilowe i współrzędnościowe maszyny pomiarowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 500 mm CMC (1·L+ 0,14) µm od 500 mm do 2800 mm CMC (2,2·L+ 0,17) µm Měřící mikroskopy, profilprojektory a souřadnicové měřicí stroje Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 500 mm CMC (1·L+ 0,14) µm 500 mm až 2800 mm CMC (2,2·L+ 0,17) µm Kp 01-019 Mikroskopy pomiarowe, projektory profilowe i wspolrzednosciowe maszyny pomiarowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 500 mm CMC (1·L+ 0,14) µm od 500 mm do 2800 mm CMC (2,2·L+ 0,17) µm Merici mikroskopy, profilprojektory a souradnicove merici stroje Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 500 mm CMC (1·L+ 0,14) µm 500 mm az 2800 mm CMC (2,2·L+ 0,17) µm Kp 01-019","search_en":"Measuring microscopes, profile projectors and coordinate measuring machines Calibration – length Comparison with parallel gauge blocks 0 mm to 500 mm CMC (1·L+ 0,14) µm 500 mm to 2800 mm CMC (2,2·L+ 0,17) µm Kp 01-019","search_zh":"测量显微镜、轮廓投影仪和坐标测量机 校准 – 长度 与量块比较 0 mm 至 500 mm CMC (1·L+ 0,14) µm 500 mm 至 2800 mm CMC (2,2·L+ 0,17) µm Kp 01-019","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"99068798e6ed53cfaf01c199","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Kątomierze","test_object_en":"Angle gauges","test_object_zh":"量角器","test_object_cs":"Úhloměry","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0° do 360°","cmc":"1,2´"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"1,2´"}],"parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"1,2´"}],"parameters_cs":[{"name":"","range":"0° až 360°","cmc":"1,2´"}],"technique":"Pomiar za pomocą płytek kątowych","technique_en":"Measurement using angle gauges","technique_zh":"使用角度块测量","technique_cs":"Měření pomocí úhlových měrek","techniques":["Pomiar za pomocą płytek kątowych"],"techniques_en":["Measurement using angle gauges"],"techniques_zh":["使用角度块测量"],"techniques_cs":["Měření pomocí úhlových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0° do 360° CMC 1,2´\nPomiar za pomocą płytek kątowych","reference":"Kp 02-002, Kp 01-015","norm_bases":["Kp 02-002","Kp 01-015"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątomierze Wzorcowanie – kąt płaski Pomiar za pomocą płytek kątowych od 0° do 360° CMC 1,2´ Úhloměry Kalibrace – rovinný úhel Měření pomocí úhlových měrek 0° až 360° CMC 1,2´ Kp 02-002, Kp 01-015 Katomierze Wzorcowanie – kat plaski Pomiar za pomoca plytek katowych od 0° do 360° CMC 1,2´ Uhlomery Kalibrace – rovinny uhel Mereni pomoci uhlovych merek 0° az 360° CMC 1,2´ Kp 02-002, Kp 01-015","search_en":"Angle gauges Calibration – plane angle Measurement using angle gauges 0° to 360° CMC 1,2´ Kp 02-002, Kp 01-015","search_zh":"量角器 校准 – 平面角 使用角度块测量 0° 至 360° CMC 1,2´ Kp 02-002, Kp 01-015","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"138439f35dfe1171434b9f4a","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Przyrządy pomiarowe i wzorniki kształtowe","test_object_en":"Measuring jigs and profile gauges","test_object_zh":"测量夹具和样板量规","test_object_cs":"Měřící přípravky a tvarová měřidla","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0° do 360°","cmc":"0,5´"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"0,5´"}],"parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"0,5´"}],"parameters_cs":[{"name":"","range":"0° až 360°","cmc":"0,5´"}],"technique":"Pomiar na mikroskopie","technique_en":"Measurement on a microscope","technique_zh":"在显微镜上测量","technique_cs":"Měření na mikroskopu","techniques":["Pomiar na mikroskopie"],"techniques_en":["Measurement on a microscope"],"techniques_zh":["在显微镜上测量"],"techniques_cs":["Měření na mikroskopu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0° do 360° CMC 0,5´\nPomiar na mikroskopie","reference":"Kp 01-017, Kp 01-015","norm_bases":["Kp 01-017","Kp 01-015"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy pomiarowe i wzorniki kształtowe Wzorcowanie – kąt płaski Pomiar na mikroskopie od 0° do 360° CMC 0,5´ Měřící přípravky a tvarová měřidla Kalibrace – rovinný úhel Měření na mikroskopu 0° až 360° CMC 0,5´ Kp 01-017, Kp 01-015 Przyrzady pomiarowe i wzorniki ksztaltowe Wzorcowanie – kat plaski Pomiar na mikroskopie od 0° do 360° CMC 0,5´ Merici pripravky a tvarova meridla Kalibrace – rovinny uhel Mereni na mikroskopu 0° az 360° CMC 0,5´ Kp 01-017, Kp 01-015","search_en":"Measuring jigs and profile gauges Calibration – plane angle Measurement on a microscope 0° to 360° CMC 0,5´ Kp 01-017, Kp 01-015","search_zh":"测量夹具和样板量规 校准 – 平面角 在显微镜上测量 0° 至 360° CMC 0,5´ Kp 01-017, Kp 01-015","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5da3216a0231d2e0cfc52f04","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"3","test_object":"Mikroskopy pomiarowe, projektory profilowe i współrzędnościowe maszyny pomiarowe","test_object_en":"Measuring microscopes, profile projectors and coordinate measuring machines","test_object_zh":"测量显微镜、轮廓投影仪和坐标测量机","test_object_cs":"Měřící mikroskopy, profilprojektory a souřadnicové měřicí stroje","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0° do 360°","cmc":"0,3´"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"0,3´"}],"parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"0,3´"}],"parameters_cs":[{"name":"","range":"0° až 360°","cmc":"0,3´"}],"technique":"Porównanie z płytkami kątowymi","technique_en":"Comparison with angle gauges","technique_zh":"与角度块比较","technique_cs":"Porovnání s úhlovými měrkami","techniques":["Porównanie z płytkami kątowymi"],"techniques_en":["Comparison with angle gauges"],"techniques_zh":["与角度块比较"],"techniques_cs":["Porovnání s úhlovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0° do 360° CMC 0,3´\nPorównanie z płytkami kątowymi","reference":"Kp 01-019","norm_bases":["Kp 01-019"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mikroskopy pomiarowe, projektory profilowe i współrzędnościowe maszyny pomiarowe Wzorcowanie – kąt płaski Porównanie z płytkami kątowymi od 0° do 360° CMC 0,3´ Měřící mikroskopy, profilprojektory a souřadnicové měřicí stroje Kalibrace – rovinný úhel Porovnání s úhlovými měrkami 0° až 360° CMC 0,3´ Kp 01-019 Mikroskopy pomiarowe, projektory profilowe i wspolrzednosciowe maszyny pomiarowe Wzorcowanie – kat plaski Porownanie z plytkami katowymi od 0° do 360° CMC 0,3´ Merici mikroskopy, profilprojektory a souradnicove merici stroje Kalibrace – rovinny uhel Porovnani s uhlovymi merkami 0° az 360° CMC 0,3´ Kp 01-019","search_en":"Measuring microscopes, profile projectors and coordinate measuring machines Calibration – plane angle Comparison with angle gauges 0° to 360° CMC 0,3´ Kp 01-019","search_zh":"测量显微镜、轮廓投影仪和坐标测量机 校准 – 平面角 与角度块比较 0° 至 360° CMC 0,3´ Kp 01-019","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"04a1e780704616cd453635ee","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Moment siły / Urządzenia do pomiaru momentu siły, klucze i wkrętaki dynamometryczne, wkrętarki pneumatyczne i elektryczne","test_object_en":"Torque / Torque measuring devices, torque wrenches and screwdrivers, pneumatic and electric nutrunners","test_object_zh":"力矩 / 力矩测量装置、扭矩扳手和螺丝刀、气动和电动拧紧机","test_object_cs":"Moment síly / Zařízení pro měření momentu síly, momentové klíče a šroubováky, pneumatické a elektrické utahovačky","methodology":"Wzorcowanie – siła","methodology_en":"Calibration – force","methodology_zh":"校准 – 力","methodology_cs":"Kalibrace – síla","parameters":[{"name":"","range":"od 0,15 Nm do 2 Nm","cmc":"0,97 %"},{"name":"","range":"od 2 Nm do 10 Nm","cmc":"0,56 %"},{"name":"","range":"od 10 Nm do 100 Nm","cmc":"0,63 %"},{"name":"","range":"od 100 Nm do 1000 Nm","cmc":"0,78 %"},{"name":"","range":"od 1000 Nm do 2000 Nm","cmc":"0,65 %"}],"parameters_en":[{"name":"","range":"0,15 Nm to 2 Nm","cmc":"0,97 %"},{"name":"","range":"2 Nm to 10 Nm","cmc":"0,56 %"},{"name":"","range":"10 Nm to 100 Nm","cmc":"0,63 %"},{"name":"","range":"100 Nm to 1000 Nm","cmc":"0,78 %"},{"name":"","range":"1000 Nm to 2000 Nm","cmc":"0,65 %"}],"parameters_zh":[{"name":"","range":"0,15 Nm 至 2 Nm","cmc":"0,97 %"},{"name":"","range":"2 Nm 至 10 Nm","cmc":"0,56 %"},{"name":"","range":"10 Nm 至 100 Nm","cmc":"0,63 %"},{"name":"","range":"100 Nm 至 1000 Nm","cmc":"0,78 %"},{"name":"","range":"1000 Nm 至 2000 Nm","cmc":"0,65 %"}],"parameters_cs":[{"name":"","range":"0,15 Nm až 2 Nm","cmc":"0,97 %"},{"name":"","range":"2 Nm až 10 Nm","cmc":"0,56 %"},{"name":"","range":"10 Nm až 100 Nm","cmc":"0,63 %"},{"name":"","range":"100 Nm až 1000 Nm","cmc":"0,78 %"},{"name":"","range":"1000 Nm až 2000 Nm","cmc":"0,65 %"}],"technique":"Porównanie z wzorcowym czujnikiem momentu siły","technique_en":"Comparison with a reference torque sensor","technique_zh":"与标准扭矩传感器比较","technique_cs":"Porovnání s etalonovým snímačem momentu síly","techniques":["Porównanie z wzorcowym czujnikiem momentu siły"],"techniques_en":["Comparison with a reference torque sensor"],"techniques_zh":["与标准扭矩传感器比较"],"techniques_cs":["Porovnání s etalonovým snímačem momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła\nZakres:\nod 0,15 Nm do 2 Nm CMC 0,97 %\nod 2 Nm do 10 Nm CMC 0,56 %\nod 10 Nm do 100 Nm CMC 0,63 %\nod 100 Nm do 1000 Nm CMC 0,78 %\nod 1000 Nm do 2000 Nm CMC 0,65 %\nPorównanie z wzorcowym czujnikiem momentu siły","reference":"Kp 03-001","norm_bases":["Kp 03-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła","regulatory_area_en":"CMC for the field of measured quantity: Force","regulatory_area_zh":"被测量领域的CMC：力","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moment siły / Urządzenia do pomiaru momentu siły, klucze i wkrętaki dynamometryczne, wkrętarki pneumatyczne i elektryczne Wzorcowanie – siła Porównanie z wzorcowym czujnikiem momentu siły od 0,15 Nm do 2 Nm CMC 0,97 % od 2 Nm do 10 Nm CMC 0,56 % od 10 Nm do 100 Nm CMC 0,63 % od 100 Nm do 1000 Nm CMC 0,78 % od 1000 Nm do 2000 Nm CMC 0,65 % Moment síly / Zařízení pro měření momentu síly, momentové klíče a šroubováky, pneumatické a elektrické utahovačky Kalibrace – síla Porovnání s etalonovým snímačem momentu síly 0,15 Nm až 2 Nm CMC 0,97 % 2 Nm až 10 Nm CMC 0,56 % 10 Nm až 100 Nm CMC 0,63 % 100 Nm až 1000 Nm CMC 0,78 % 1000 Nm až 2000 Nm CMC 0,65 % Kp 03-001 Moment sily / Urzadzenia do pomiaru momentu sily, klucze i wkretaki dynamometryczne, wkretarki pneumatyczne i elektryczne Wzorcowanie – sila Porownanie z wzorcowym czujnikiem momentu sily od 0,15 Nm do 2 Nm CMC 0,97 % od 2 Nm do 10 Nm CMC 0,56 % od 10 Nm do 100 Nm CMC 0,63 % od 100 Nm do 1000 Nm CMC 0,78 % od 1000 Nm do 2000 Nm CMC 0,65 % Moment sily / Zarizeni pro mereni momentu sily, momentove klice a sroubovaky, pneumaticke a elektricke utahovacky Kalibrace – sila Porovnani s etalonovym snimacem momentu sily 0,15 Nm az 2 Nm CMC 0,97 % 2 Nm az 10 Nm CMC 0,56 % 10 Nm az 100 Nm CMC 0,63 % 100 Nm az 1000 Nm CMC 0,78 % 1000 Nm az 2000 Nm CMC 0,65 % Kp 03-001","search_en":"Torque / Torque measuring devices, torque wrenches and screwdrivers, pneumatic and electric nutrunners Calibration – force Comparison with a reference torque sensor 0,15 Nm to 2 Nm CMC 0,97 % 2 Nm to 10 Nm CMC 0,56 % 10 Nm to 100 Nm CMC 0,63 % 100 Nm to 1000 Nm CMC 0,78 % 1000 Nm to 2000 Nm CMC 0,65 % Kp 03-001","search_zh":"力矩 / 力矩测量装置、扭矩扳手和螺丝刀、气动和电动拧紧机 校准 – 力 与标准扭矩传感器比较 0,15 Nm 至 2 Nm CMC 0,97 % 2 Nm 至 10 Nm CMC 0,56 % 10 Nm 至 100 Nm CMC 0,63 % 100 Nm 至 1000 Nm CMC 0,78 % 1000 Nm 至 2000 Nm CMC 0,65 % Kp 03-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e13eb9bbe5123c864768192b","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Siła / Siłomierze i urządzenia siłomiercze","test_object_en":"Force / Force meters and force measuring devices","test_object_zh":"力 / 测力计和测力装置","test_object_cs":"Síla / Siloměry a siloměrná zařízení","methodology":"Wzorcowanie – siła","methodology_en":"Calibration – force","methodology_zh":"校准 – 力","methodology_cs":"Kalibrace – síla","parameters":[{"name":"Rozciąganie i ściskanie","range":"od 0,5 N do 500 N","cmc":"0,24 %"}],"parameters_en":[{"name":"Tension and compression","range":"0,5 N to 500 N","cmc":"0,24 %"}],"parameters_zh":[{"name":"拉伸和压缩","range":"0,5 N 至 500 N","cmc":"0,24 %"}],"parameters_cs":[{"name":"Tah a tlak","range":"0,5 N až 500 N","cmc":"0,24 %"}],"technique":"Porównanie z wzorcowymi obciążnikami","technique_en":"Comparison with reference loading weights","technique_zh":"与标准加载砝码比较","technique_cs":"Porovnání s etalonovými zatěžovacími tělesy","techniques":["Porównanie z wzorcowymi obciążnikami"],"techniques_en":["Comparison with reference loading weights"],"techniques_zh":["与标准加载砝码比较"],"techniques_cs":["Porovnání s etalonovými zatěžovacími tělesy"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła\nRozciąganie i ściskanie od 0,5 N do 500 N CMC 0,24 %\nPorównanie z wzorcowymi obciążnikami","reference":"Kp 03-002","norm_bases":["Kp 03-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła","regulatory_area_en":"CMC for the field of measured quantity: Force","regulatory_area_zh":"被测量领域的CMC：力","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Siła / Siłomierze i urządzenia siłomiercze Wzorcowanie – siła Porównanie z wzorcowymi obciążnikami Rozciąganie i ściskanie od 0,5 N do 500 N CMC 0,24 % Síla / Siloměry a siloměrná zařízení Kalibrace – síla Porovnání s etalonovými zatěžovacími tělesy Tah a tlak 0,5 N až 500 N CMC 0,24 % Kp 03-002 Sila / Silomierze i urzadzenia silomiercze Wzorcowanie – sila Porownanie z wzorcowymi obciaznikami Rozciaganie i sciskanie od 0,5 N do 500 N CMC 0,24 % Sila / Silomery a silomerna zarizeni Kalibrace – sila Porovnani s etalonovymi zatezovacimi telesy Tah a tlak 0,5 N az 500 N CMC 0,24 % Kp 03-002","search_en":"Force / Force meters and force measuring devices Calibration – force Comparison with reference loading weights Tension and compression 0,5 N to 500 N CMC 0,24 % Kp 03-002","search_zh":"力 / 测力计和测力装置 校准 – 力 与标准加载砝码比较 拉伸和压缩 0,5 N 至 500 N CMC 0,24 % Kp 03-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"74015d5b73ee6c7583025b38","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, tory pomiarowe ciśnienia","test_object_en":"Deformation and digital pressure gauges, pressure transducers, pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器、压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku, měřící řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"nadciśnienie; gaz","range":"od -90 kPa do 100 kPa","cmc":"0,12 kPa"},{"name":"nadciśnienie; gaz","range":"od 0,1 MPa do 2 MPa","cmc":"1,2 kPa"},{"name":"nadciśnienie; ciecz","range":"od 0 MPa do 2 MPa","cmc":"1,2 kPa"},{"name":"nadciśnienie; ciecz","range":"od 2 MPa do 10 MPa","cmc":"6,0 kPa"},{"name":"nadciśnienie; ciecz","range":"od 10 MPa do 100 MPa","cmc":"59 kPa"},{"name":"Ciśnienie bezwzględne; gaz","range":"od 30 kPa do 170 kPa","cmc":"0,29 kPa"},{"name":"Ciśnienie bezwzględne; gaz","range":"od 0,17 MPa do 2,1 MPa","cmc":"1,3 kPa"},{"name":"Ciśnienie bezwzględne; ciecz","range":"od 0,1 MPa do 2,1 MPa","cmc":"1,3 kPa"},{"name":"Ciśnienie bezwzględne; ciecz","range":"od 2,1 MPa do 10 MPa","cmc":"6,1 kPa"},{"name":"Ciśnienie bezwzględne; ciecz","range":"od 10 MPa do 100 MPa","cmc":"59 kPa"},{"name":"Ciśnienie barometryczne","range":"od 70 kPa do 110 kPa","cmc":"0,26 kPa"}],"parameters_en":[{"name":"positive gauge pressure; gas","range":"-90 kPa to 100 kPa","cmc":"0,12 kPa"},{"name":"positive gauge pressure; gas","range":"0,1 MPa to 2 MPa","cmc":"1,2 kPa"},{"name":"positive gauge pressure; liquid","range":"0 MPa to 2 MPa","cmc":"1,2 kPa"},{"name":"positive gauge pressure; liquid","range":"2 MPa to 10 MPa","cmc":"6,0 kPa"},{"name":"positive gauge pressure; liquid","range":"10 MPa to 100 MPa","cmc":"59 kPa"},{"name":"Absolute pressure; gas","range":"30 kPa to 170 kPa","cmc":"0,29 kPa"},{"name":"Absolute pressure; gas","range":"0,17 MPa to 2,1 MPa","cmc":"1,3 kPa"},{"name":"Absolute pressure; liquid","range":"0,1 MPa to 2,1 MPa","cmc":"1,3 kPa"},{"name":"Absolute pressure; liquid","range":"2,1 MPa to 10 MPa","cmc":"6,1 kPa"},{"name":"Absolute pressure; liquid","range":"10 MPa to 100 MPa","cmc":"59 kPa"},{"name":"Barometric pressure","range":"70 kPa to 110 kPa","cmc":"0,26 kPa"}],"parameters_zh":[{"name":"表压；气体","range":"-90 kPa 至 100 kPa","cmc":"0,12 kPa"},{"name":"表压；气体","range":"0,1 MPa 至 2 MPa","cmc":"1,2 kPa"},{"name":"表压；液体","range":"0 MPa 至 2 MPa","cmc":"1,2 kPa"},{"name":"表压；液体","range":"2 MPa 至 10 MPa","cmc":"6,0 kPa"},{"name":"表压；液体","range":"10 MPa 至 100 MPa","cmc":"59 kPa"},{"name":"绝对压力；气体","range":"30 kPa 至 170 kPa","cmc":"0,29 kPa"},{"name":"绝对压力；气体","range":"0,17 MPa 至 2,1 MPa","cmc":"1,3 kPa"},{"name":"绝对压力；液体","range":"0,1 MPa 至 2,1 MPa","cmc":"1,3 kPa"},{"name":"绝对压力；液体","range":"2,1 MPa 至 10 MPa","cmc":"6,1 kPa"},{"name":"绝对压力；液体","range":"10 MPa 至 100 MPa","cmc":"59 kPa"},{"name":"大气压力","range":"70 kPa 至 110 kPa","cmc":"0,26 kPa"}],"parameters_cs":[{"name":"přetlak; plyn","range":"-90 kPa až 100 kPa","cmc":"0,12 kPa"},{"name":"přetlak; plyn","range":"0,1 MPa až 2 MPa","cmc":"1,2 kPa"},{"name":"přetlak; kapalina","range":"0 MPa až 2 MPa","cmc":"1,2 kPa"},{"name":"přetlak; kapalina","range":"2 MPa až 10 MPa","cmc":"6,0 kPa"},{"name":"přetlak; kapalina","range":"10 MPa až 100 MPa","cmc":"59 kPa"},{"name":"Absolutní tlak; plyn","range":"30 kPa až 170 kPa","cmc":"0,29 kPa"},{"name":"Absolutní tlak; plyn","range":"0,17 MPa až 2,1 MPa","cmc":"1,3 kPa"},{"name":"Absolutní tlak; kapalina","range":"0,1 MPa až 2,1 MPa","cmc":"1,3 kPa"},{"name":"Absolutní tlak; kapalina","range":"2,1 MPa až 10 MPa","cmc":"6,1 kPa"},{"name":"Absolutní tlak; kapalina","range":"10 MPa až 100 MPa","cmc":"59 kPa"},{"name":"Barometrický tlak","range":"70 kPa až 110 kPa","cmc":"0,26 kPa"}],"technique":"Porównanie z ciśnieniomierzem wzorcowym","technique_en":"Comparison with a reference pressure gauge","technique_zh":"与标准压力表比较","technique_cs":"Porovnání s etalonovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem wzorcowym"],"techniques_en":["Comparison with a reference pressure gauge"],"techniques_zh":["与标准压力表比较"],"techniques_cs":["Porovnání s etalonovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nnadciśnienie; gaz od -90 kPa do 100 kPa CMC 0,12 kPa\nnadciśnienie; gaz od 0,1 MPa do 2 MPa CMC 1,2 kPa\nnadciśnienie; ciecz od 0 MPa do 2 MPa CMC 1,2 kPa\nnadciśnienie; ciecz od 2 MPa do 10 MPa CMC 6,0 kPa\nnadciśnienie; ciecz od 10 MPa do 100 MPa CMC 59 kPa\nCiśnienie bezwzględne; gaz od 30 kPa do 170 kPa CMC 0,29 kPa\nCiśnienie bezwzględne; gaz od 0,17 MPa do 2,1 MPa CMC 1,3 kPa\nCiśnienie bezwzględne; ciecz od 0,1 MPa do 2,1 MPa CMC 1,3 kPa\nCiśnienie bezwzględne; ciecz od 2,1 MPa do 10 MPa CMC 6,1 kPa\nCiśnienie bezwzględne; ciecz od 10 MPa do 100 MPa CMC 59 kPa\nCiśnienie barometryczne od 70 kPa do 110 kPa CMC 0,26 kPa\nPorównanie z ciśnieniomierzem wzorcowym","reference":"Kp 05-001","norm_bases":["Kp 05-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":"Ciśnienie wynikowe jest sumą ciśnienia względnego i barometrycznego. Niepewność wynikowa składa się z niepewności ciśnienia względnego i barometrycznego","note_en":"The resulting pressure is the sum of relative and barometric pressure. The resulting uncertainty is the combination of relative and barometric pressure uncertainty","note_zh":"所得压力为相对压力与大气压力之和。所得不确定度由相对压力和大气压力的不确定度组成","note_cs":"Výsledný tlak je součtem relativního a barometrického tlaku. Výsledná nejistota je tvořena nejistotou relativního a barometrického tlaku","search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z ciśnieniomierzem wzorcowym nadciśnienie; gaz od -90 kPa do 100 kPa CMC 0,12 kPa nadciśnienie; gaz od 0,1 MPa do 2 MPa CMC 1,2 kPa nadciśnienie; ciecz od 0 MPa do 2 MPa CMC 1,2 kPa nadciśnienie; ciecz od 2 MPa do 10 MPa CMC 6,0 kPa nadciśnienie; ciecz od 10 MPa do 100 MPa CMC 59 kPa Ciśnienie bezwzględne; gaz od 30 kPa do 170 kPa CMC 0,29 kPa Ciśnienie bezwzględne; gaz od 0,17 MPa do 2,1 MPa CMC 1,3 kPa Ciśnienie bezwzględne; ciecz od 0,1 MPa do 2,1 MPa CMC 1,3 kPa Ciśnienie bezwzględne; ciecz od 2,1 MPa do 10 MPa CMC 6,1 kPa Ciśnienie bezwzględne; ciecz od 10 MPa do 100 MPa CMC 59 kPa Ciśnienie barometryczne od 70 kPa do 110 kPa CMC 0,26 kPa Deformační a číslicové tlakoměry, převodníky tlaku, měřící řetězce tlaku Kalibrace – tlak Porovnání s etalonovým tlakoměrem přetlak; plyn -90 kPa až 100 kPa CMC 0,12 kPa přetlak; plyn 0,1 MPa až 2 MPa CMC 1,2 kPa přetlak; kapalina 0 MPa až 2 MPa CMC 1,2 kPa přetlak; kapalina 2 MPa až 10 MPa CMC 6,0 kPa přetlak; kapalina 10 MPa až 100 MPa CMC 59 kPa Absolutní tlak; plyn 30 kPa až 170 kPa CMC 0,29 kPa Absolutní tlak; plyn 0,17 MPa až 2,1 MPa CMC 1,3 kPa Absolutní tlak; kapalina 0,1 MPa až 2,1 MPa CMC 1,3 kPa Absolutní tlak; kapalina 2,1 MPa až 10 MPa CMC 6,1 kPa Absolutní tlak; kapalina 10 MPa až 100 MPa CMC 59 kPa Barometrický tlak 70 kPa až 110 kPa CMC 0,26 kPa Kp 05-001 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia, tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z cisnieniomierzem wzorcowym nadcisnienie; gaz od -90 kPa do 100 kPa CMC 0,12 kPa nadcisnienie; gaz od 0,1 MPa do 2 MPa CMC 1,2 kPa nadcisnienie; ciecz od 0 MPa do 2 MPa CMC 1,2 kPa nadcisnienie; ciecz od 2 MPa do 10 MPa CMC 6,0 kPa nadcisnienie; ciecz od 10 MPa do 100 MPa CMC 59 kPa Cisnienie bezwzgledne; gaz od 30 kPa do 170 kPa CMC 0,29 kPa Cisnienie bezwzgledne; gaz od 0,17 MPa do 2,1 MPa CMC 1,3 kPa Cisnienie bezwzgledne; ciecz od 0,1 MPa do 2,1 MPa CMC 1,3 kPa Cisnienie bezwzgledne; ciecz od 2,1 MPa do 10 MPa CMC 6,1 kPa Cisnienie bezwzgledne; ciecz od 10 MPa do 100 MPa CMC 59 kPa Cisnienie barometryczne od 70 kPa do 110 kPa CMC 0,26 kPa Deformacni a cislicove tlakomery, prevodniky tlaku, merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym tlakomerem pretlak; plyn -90 kPa az 100 kPa CMC 0,12 kPa pretlak; plyn 0,1 MPa az 2 MPa CMC 1,2 kPa pretlak; kapalina 0 MPa az 2 MPa CMC 1,2 kPa pretlak; kapalina 2 MPa az 10 MPa CMC 6,0 kPa pretlak; kapalina 10 MPa az 100 MPa CMC 59 kPa Absolutni tlak; plyn 30 kPa az 170 kPa CMC 0,29 kPa Absolutni tlak; plyn 0,17 MPa az 2,1 MPa CMC 1,3 kPa Absolutni tlak; kapalina 0,1 MPa az 2,1 MPa CMC 1,3 kPa Absolutni tlak; kapalina 2,1 MPa az 10 MPa CMC 6,1 kPa Absolutni tlak; kapalina 10 MPa az 100 MPa CMC 59 kPa Barometricky tlak 70 kPa az 110 kPa CMC 0,26 kPa Kp 05-001","search_en":"Deformation and digital pressure gauges, pressure transducers, pressure measuring chains Calibration – pressure Comparison with a reference pressure gauge positive gauge pressure; gas -90 kPa to 100 kPa CMC 0,12 kPa positive gauge pressure; gas 0,1 MPa to 2 MPa CMC 1,2 kPa positive gauge pressure; liquid 0 MPa to 2 MPa CMC 1,2 kPa positive gauge pressure; liquid 2 MPa to 10 MPa CMC 6,0 kPa positive gauge pressure; liquid 10 MPa to 100 MPa CMC 59 kPa Absolute pressure; gas 30 kPa to 170 kPa CMC 0,29 kPa Absolute pressure; gas 0,17 MPa to 2,1 MPa CMC 1,3 kPa Absolute pressure; liquid 0,1 MPa to 2,1 MPa CMC 1,3 kPa Absolute pressure; liquid 2,1 MPa to 10 MPa CMC 6,1 kPa Absolute pressure; liquid 10 MPa to 100 MPa CMC 59 kPa Barometric pressure 70 kPa to 110 kPa CMC 0,26 kPa Kp 05-001","search_zh":"弹性式和数字式压力表、压力变送器、压力测量链 校准 – 压力 与标准压力表比较 表压；气体 -90 kPa 至 100 kPa CMC 0,12 kPa 表压；气体 0,1 MPa 至 2 MPa CMC 1,2 kPa 表压；液体 0 MPa 至 2 MPa CMC 1,2 kPa 表压；液体 2 MPa 至 10 MPa CMC 6,0 kPa 表压；液体 10 MPa 至 100 MPa CMC 59 kPa 绝对压力；气体 30 kPa 至 170 kPa CMC 0,29 kPa 绝对压力；气体 0,17 MPa 至 2,1 MPa CMC 1,3 kPa 绝对压力；液体 0,1 MPa 至 2,1 MPa CMC 1,3 kPa 绝对压力；液体 2,1 MPa 至 10 MPa CMC 6,1 kPa 绝对压力；液体 10 MPa 至 100 MPa CMC 59 kPa 大气压力 70 kPa 至 110 kPa CMC 0,26 kPa Kp 05-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b38dd88b4c14bf2992fdb3e8","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące i tory pomiarowe temperatury","test_object_en":"Indicating thermometers and temperature measuring chains","test_object_zh":"指示式温度计和温度测量链","test_object_cs":"Indikační teploměry a měřící řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -20 °C do -5 °C","cmc":"0,34 °C"},{"name":"","range":"od -5 °C do 50 °C","cmc":"0,27 °C"},{"name":"","range":"od 50 °C do 100 °C","cmc":"0,48 °C"},{"name":"","range":"od 100 °C do 650 °C","cmc":"0,64 °C"}],"parameters_en":[{"name":"","range":"-20 °C to -5 °C","cmc":"0,34 °C"},{"name":"","range":"-5 °C to 50 °C","cmc":"0,27 °C"},{"name":"","range":"50 °C to 100 °C","cmc":"0,48 °C"},{"name":"","range":"100 °C to 650 °C","cmc":"0,64 °C"}],"parameters_zh":[{"name":"","range":"-20 °C 至 -5 °C","cmc":"0,34 °C"},{"name":"","range":"-5 °C 至 50 °C","cmc":"0,27 °C"},{"name":"","range":"50 °C 至 100 °C","cmc":"0,48 °C"},{"name":"","range":"100 °C 至 650 °C","cmc":"0,64 °C"}],"parameters_cs":[{"name":"","range":"-20 °C až -5 °C","cmc":"0,34 °C"},{"name":"","range":"-5 °C až 50 °C","cmc":"0,27 °C"},{"name":"","range":"50 °C až 100 °C","cmc":"0,48 °C"},{"name":"","range":"100 °C až 650 °C","cmc":"0,64 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecyku blokowym","technique_en":"Comparison with a reference thermometer in a dry block","technique_zh":"在干井炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v blokové pícce","techniques":["Porównanie z termometrem wzorcowym w piecyku blokowym"],"techniques_en":["Comparison with a reference thermometer in a dry block"],"techniques_zh":["在干井炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v blokové pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -20 °C do -5 °C CMC 0,34 °C\nod -5 °C do 50 °C CMC 0,27 °C\nod 50 °C do 100 °C CMC 0,48 °C\nod 100 °C do 650 °C CMC 0,64 °C\nPorównanie z termometrem wzorcowym w piecyku blokowym","reference":"Kp 07-001","norm_bases":["Kp 07-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecyku blokowym od -20 °C do -5 °C CMC 0,34 °C od -5 °C do 50 °C CMC 0,27 °C od 50 °C do 100 °C CMC 0,48 °C od 100 °C do 650 °C CMC 0,64 °C Indikační teploměry a měřící řetězce teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v blokové pícce -20 °C až -5 °C CMC 0,34 °C -5 °C až 50 °C CMC 0,27 °C 50 °C až 100 °C CMC 0,48 °C 100 °C až 650 °C CMC 0,64 °C Kp 07-001 Termometry wskazujace i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecyku blokowym od -20 °C do -5 °C CMC 0,34 °C od -5 °C do 50 °C CMC 0,27 °C od 50 °C do 100 °C CMC 0,48 °C od 100 °C do 650 °C CMC 0,64 °C Indikacni teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v blokove picce -20 °C az -5 °C CMC 0,34 °C -5 °C az 50 °C CMC 0,27 °C 50 °C az 100 °C CMC 0,48 °C 100 °C az 650 °C CMC 0,64 °C Kp 07-001","search_en":"Indicating thermometers and temperature measuring chains Calibration – temperature Comparison with a reference thermometer in a dry block -20 °C to -5 °C CMC 0,34 °C -5 °C to 50 °C CMC 0,27 °C 50 °C to 100 °C CMC 0,48 °C 100 °C to 650 °C CMC 0,64 °C Kp 07-001","search_zh":"指示式温度计和温度测量链 校准 – 温度 在干井炉中与标准温度计比较 -20 °C 至 -5 °C CMC 0,34 °C -5 °C 至 50 °C CMC 0,27 °C 50 °C 至 100 °C CMC 0,48 °C 100 °C 至 650 °C CMC 0,64 °C Kp 07-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"230d3a05fec38e9985e00deb","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące i tory pomiarowe temperatury","test_object_en":"Indicating thermometers and temperature measuring chains","test_object_zh":"指示式温度计和温度测量链","test_object_cs":"Indikační teploměry a měřící řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -5 °C do 40 °C","cmc":"0,90 °C"}],"parameters_en":[{"name":"","range":"-5 °C to 40 °C","cmc":"0,90 °C"}],"parameters_zh":[{"name":"","range":"-5 °C 至 40 °C","cmc":"0,90 °C"}],"parameters_cs":[{"name":"","range":"-5 °C až 40 °C","cmc":"0,90 °C"}],"technique":"Porównanie z termometrem wzorcowym w komorze klimatycznej","technique_en":"Comparison with a reference thermometer in a climatic chamber","technique_zh":"在气候箱中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v klimatické komoře","techniques":["Porównanie z termometrem wzorcowym w komorze klimatycznej"],"techniques_en":["Comparison with a reference thermometer in a climatic chamber"],"techniques_zh":["在气候箱中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -5 °C do 40 °C CMC 0,90 °C\nPorównanie z termometrem wzorcowym w komorze klimatycznej","reference":"Kp 07-001","norm_bases":["Kp 07-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w komorze klimatycznej od -5 °C do 40 °C CMC 0,90 °C Indikační teploměry a měřící řetězce teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v klimatické komoře -5 °C až 40 °C CMC 0,90 °C Kp 07-001 Termometry wskazujace i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w komorze klimatycznej od -5 °C do 40 °C CMC 0,90 °C Indikacni teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v klimaticke komore -5 °C az 40 °C CMC 0,90 °C Kp 07-001","search_en":"Indicating thermometers and temperature measuring chains Calibration – temperature Comparison with a reference thermometer in a climatic chamber -5 °C to 40 °C CMC 0,90 °C Kp 07-001","search_zh":"指示式温度计和温度测量链 校准 – 温度 在气候箱中与标准温度计比较 -5 °C 至 40 °C CMC 0,90 °C Kp 07-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3fd3a6168037eae61e905cfb","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Termometry bezdotykowe","test_object_en":"Non-contact thermometers","test_object_zh":"非接触式温度计","test_object_cs":"Bezdotykové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 30 °C do 100 °C","cmc":"1,7 °C"},{"name":"","range":"od 100 °C do 200 °C","cmc":"2,6 °C"},{"name":"","range":"od 200 °C do 300 °C","cmc":"2,7 °C"},{"name":"","range":"od 300 °C do 400 °C","cmc":"3,0 °C"},{"name":"","range":"od 400 °C do 500 °C","cmc":"3,3 °C"}],"parameters_en":[{"name":"","range":"30 °C to 100 °C","cmc":"1,7 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"2,6 °C"},{"name":"","range":"200 °C to 300 °C","cmc":"2,7 °C"},{"name":"","range":"300 °C to 400 °C","cmc":"3,0 °C"},{"name":"","range":"400 °C to 500 °C","cmc":"3,3 °C"}],"parameters_zh":[{"name":"","range":"30 °C 至 100 °C","cmc":"1,7 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"2,6 °C"},{"name":"","range":"200 °C 至 300 °C","cmc":"2,7 °C"},{"name":"","range":"300 °C 至 400 °C","cmc":"3,0 °C"},{"name":"","range":"400 °C 至 500 °C","cmc":"3,3 °C"}],"parameters_cs":[{"name":"","range":"30 °C až 100 °C","cmc":"1,7 °C"},{"name":"","range":"100 °C až 200 °C","cmc":"2,6 °C"},{"name":"","range":"200 °C až 300 °C","cmc":"2,7 °C"},{"name":"","range":"300 °C až 400 °C","cmc":"3,0 °C"},{"name":"","range":"400 °C až 500 °C","cmc":"3,3 °C"}],"technique":"Porównanie z wzorcowym ciałem czarnym tarczowym","technique_en":"Comparison with a reference target black body","technique_zh":"与标准靶式黑体比较","technique_cs":"Porovnání s etalonovým terčovým černým tělesem","techniques":["Porównanie z wzorcowym ciałem czarnym tarczowym"],"techniques_en":["Comparison with a reference target black body"],"techniques_zh":["与标准靶式黑体比较"],"techniques_cs":["Porovnání s etalonovým terčovým černým tělesem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 30 °C do 100 °C CMC 1,7 °C\nod 100 °C do 200 °C CMC 2,6 °C\nod 200 °C do 300 °C CMC 2,7 °C\nod 300 °C do 400 °C CMC 3,0 °C\nod 400 °C do 500 °C CMC 3,3 °C\nPorównanie z wzorcowym ciałem czarnym tarczowym","reference":"Kp 07-002","norm_bases":["Kp 07-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezdotykowe Wzorcowanie – temperatura Porównanie z wzorcowym ciałem czarnym tarczowym od 30 °C do 100 °C CMC 1,7 °C od 100 °C do 200 °C CMC 2,6 °C od 200 °C do 300 °C CMC 2,7 °C od 300 °C do 400 °C CMC 3,0 °C od 400 °C do 500 °C CMC 3,3 °C Bezdotykové teploměry Kalibrace – teplota Porovnání s etalonovým terčovým černým tělesem 30 °C až 100 °C CMC 1,7 °C 100 °C až 200 °C CMC 2,6 °C 200 °C až 300 °C CMC 2,7 °C 300 °C až 400 °C CMC 3,0 °C 400 °C až 500 °C CMC 3,3 °C Kp 07-002 Termometry bezdotykowe Wzorcowanie – temperatura Porownanie z wzorcowym cialem czarnym tarczowym od 30 °C do 100 °C CMC 1,7 °C od 100 °C do 200 °C CMC 2,6 °C od 200 °C do 300 °C CMC 2,7 °C od 300 °C do 400 °C CMC 3,0 °C od 400 °C do 500 °C CMC 3,3 °C Bezdotykove teplomery Kalibrace – teplota Porovnani s etalonovym tercovym cernym telesem 30 °C az 100 °C CMC 1,7 °C 100 °C az 200 °C CMC 2,6 °C 200 °C az 300 °C CMC 2,7 °C 300 °C az 400 °C CMC 3,0 °C 400 °C az 500 °C CMC 3,3 °C Kp 07-002","search_en":"Non-contact thermometers Calibration – temperature Comparison with a reference target black body 30 °C to 100 °C CMC 1,7 °C 100 °C to 200 °C CMC 2,6 °C 200 °C to 300 °C CMC 2,7 °C 300 °C to 400 °C CMC 3,0 °C 400 °C to 500 °C CMC 3,3 °C Kp 07-002","search_zh":"非接触式温度计 校准 – 温度 与标准靶式黑体比较 30 °C 至 100 °C CMC 1,7 °C 100 °C 至 200 °C CMC 2,6 °C 200 °C 至 300 °C CMC 2,7 °C 300 °C 至 400 °C CMC 3,0 °C 400 °C 至 500 °C CMC 3,3 °C Kp 07-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3b423c7c0c4a6927ebbc93a1","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"3","test_object":"Symulacja sygnałów czujników temperatury / jednostki przetwarzające czujników temperatury","test_object_en":"Simulation of temperature sensor signals / temperature sensor processing units","test_object_zh":"温度传感器信号的模拟 / 温度传感器处理单元","test_object_cs":"Simulace signálů snímačů teploty / vyhodnocovací jednotky teplotních snímačů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"J","range":"od -210 °C do -100 °C","cmc":"0,57 °C"},{"name":"J","range":"od -100 °C do 150 °C","cmc":"0,33 °C"},{"name":"J","range":"od 150 °C do 760 °C","cmc":"0,38 °C"},{"name":"J","range":"od 760 °C do 1200 °C","cmc":"0,48 °C"},{"name":"K","range":"od -200 °C do -100 °C","cmc":"0,66 °C"},{"name":"K","range":"od -100 °C do 120 °C","cmc":"0,40 °C"},{"name":"K","range":"od 120 °C do 1370 °C","cmc":"0,63 °C"},{"name":"T","range":"od -250 °C do -150 °C","cmc":"1,5 °C"},{"name":"T","range":"od -150 °C do 400 °C","cmc":"0,37 °C"},{"name":"R","range":"od 0 °C do 250 °C","cmc":"1,9 °C"},{"name":"R","range":"od 250 °C do 1760 °C","cmc":"1,2 °C"},{"name":"S","range":"od 0 °C do 250 °C","cmc":"1,9 °C"},{"name":"S","range":"od 250 °C do 1760 °C","cmc":"1,2 °C"},{"name":"B","range":"od 600 °C do 1820 °C","cmc":"1,8 °C"},{"name":"N","range":"od -200 °C do -100 °C","cmc":"1,0 °C"},{"name":"N","range":"od -100 °C do 410 °C","cmc":"0,51 °C"},{"name":"N","range":"od 410 °C do 1300 °C","cmc":"0,59 °C"},{"name":"E","range":"od -250 °C do -100 °C","cmc":"1,3 °C"},{"name":"E","range":"od -100 °C do 650 °C","cmc":"0,47 °C"},{"name":"E","range":"od 650 °C do 1000 °C","cmc":"0,51 °C"},{"name":"L","range":"od -200 °C do 900 °C","cmc":"0,81 °C"},{"name":"U","range":"od -200 °C do 600 °C","cmc":"0,95 °C"},{"name":"C","range":"od 0 °C do 1000 °C","cmc":"0,72 °C"},{"name":"C","range":"od 1000 °C do 2310 °C","cmc":"1,7 °C"}],"parameters_en":[{"name":"J","range":"-210 °C to -100 °C","cmc":"0,57 °C"},{"name":"J","range":"-100 °C to 150 °C","cmc":"0,33 °C"},{"name":"J","range":"150 °C to 760 °C","cmc":"0,38 °C"},{"name":"J","range":"760 °C to 1200 °C","cmc":"0,48 °C"},{"name":"K","range":"-200 °C to -100 °C","cmc":"0,66 °C"},{"name":"K","range":"-100 °C to 120 °C","cmc":"0,40 °C"},{"name":"K","range":"120 °C to 1370 °C","cmc":"0,63 °C"},{"name":"T","range":"-250 °C to -150 °C","cmc":"1,5 °C"},{"name":"T","range":"-150 °C to 400 °C","cmc":"0,37 °C"},{"name":"R","range":"0 °C to 250 °C","cmc":"1,9 °C"},{"name":"R","range":"250 °C to 1760 °C","cmc":"1,2 °C"},{"name":"S","range":"0 °C to 250 °C","cmc":"1,9 °C"},{"name":"S","range":"250 °C to 1760 °C","cmc":"1,2 °C"},{"name":"B","range":"600 °C to 1820 °C","cmc":"1,8 °C"},{"name":"N","range":"-200 °C to -100 °C","cmc":"1,0 °C"},{"name":"N","range":"-100 °C to 410 °C","cmc":"0,51 °C"},{"name":"N","range":"410 °C to 1300 °C","cmc":"0,59 °C"},{"name":"E","range":"-250 °C to -100 °C","cmc":"1,3 °C"},{"name":"E","range":"-100 °C to 650 °C","cmc":"0,47 °C"},{"name":"E","range":"650 °C to 1000 °C","cmc":"0,51 °C"},{"name":"L","range":"-200 °C to 900 °C","cmc":"0,81 °C"},{"name":"U","range":"-200 °C to 600 °C","cmc":"0,95 °C"},{"name":"C","range":"0 °C to 1000 °C","cmc":"0,72 °C"},{"name":"C","range":"1000 °C to 2310 °C","cmc":"1,7 °C"}],"parameters_zh":[{"name":"J 型","range":"-210 °C 至 -100 °C","cmc":"0,57 °C"},{"name":"J 型","range":"-100 °C 至 150 °C","cmc":"0,33 °C"},{"name":"J 型","range":"150 °C 至 760 °C","cmc":"0,38 °C"},{"name":"J 型","range":"760 °C 至 1200 °C","cmc":"0,48 °C"},{"name":"K 型","range":"-200 °C 至 -100 °C","cmc":"0,66 °C"},{"name":"K 型","range":"-100 °C 至 120 °C","cmc":"0,40 °C"},{"name":"K 型","range":"120 °C 至 1370 °C","cmc":"0,63 °C"},{"name":"T 型","range":"-250 °C 至 -150 °C","cmc":"1,5 °C"},{"name":"T 型","range":"-150 °C 至 400 °C","cmc":"0,37 °C"},{"name":"R 型","range":"0 °C 至 250 °C","cmc":"1,9 °C"},{"name":"R 型","range":"250 °C 至 1760 °C","cmc":"1,2 °C"},{"name":"S 型","range":"0 °C 至 250 °C","cmc":"1,9 °C"},{"name":"S 型","range":"250 °C 至 1760 °C","cmc":"1,2 °C"},{"name":"B 型","range":"600 °C 至 1820 °C","cmc":"1,8 °C"},{"name":"N 型","range":"-200 °C 至 -100 °C","cmc":"1,0 °C"},{"name":"N 型","range":"-100 °C 至 410 °C","cmc":"0,51 °C"},{"name":"N 型","range":"410 °C 至 1300 °C","cmc":"0,59 °C"},{"name":"E 型","range":"-250 °C 至 -100 °C","cmc":"1,3 °C"},{"name":"E 型","range":"-100 °C 至 650 °C","cmc":"0,47 °C"},{"name":"E 型","range":"650 °C 至 1000 °C","cmc":"0,51 °C"},{"name":"L 型","range":"-200 °C 至 900 °C","cmc":"0,81 °C"},{"name":"U 型","range":"-200 °C 至 600 °C","cmc":"0,95 °C"},{"name":"C 型","range":"0 °C 至 1000 °C","cmc":"0,72 °C"},{"name":"C 型","range":"1000 °C 至 2310 °C","cmc":"1,7 °C"}],"parameters_cs":[{"name":"J","range":"-210 °C až -100 °C","cmc":"0,57 °C"},{"name":"J","range":"-100 °C až 150 °C","cmc":"0,33 °C"},{"name":"J","range":"150 °C až 760 °C","cmc":"0,38 °C"},{"name":"J","range":"760 °C až 1200 °C","cmc":"0,48 °C"},{"name":"K","range":"-200 °C až -100 °C","cmc":"0,66 °C"},{"name":"K","range":"-100 °C až 120 °C","cmc":"0,40 °C"},{"name":"K","range":"120 °C až 1370 °C","cmc":"0,63 °C"},{"name":"T","range":"-250 °C až -150 °C","cmc":"1,5 °C"},{"name":"T","range":"-150 °C až 400 °C","cmc":"0,37 °C"},{"name":"R","range":"0 °C až 250 °C","cmc":"1,9 °C"},{"name":"R","range":"250 °C až 1760 °C","cmc":"1,2 °C"},{"name":"S","range":"0 °C až 250 °C","cmc":"1,9 °C"},{"name":"S","range":"250 °C až 1760 °C","cmc":"1,2 °C"},{"name":"B","range":"600 °C až 1820 °C","cmc":"1,8 °C"},{"name":"N","range":"-200 °C až -100 °C","cmc":"1,0 °C"},{"name":"N","range":"-100 °C až 410 °C","cmc":"0,51 °C"},{"name":"N","range":"410 °C až 1300 °C","cmc":"0,59 °C"},{"name":"E","range":"-250 °C až -100 °C","cmc":"1,3 °C"},{"name":"E","range":"-100 °C až 650 °C","cmc":"0,47 °C"},{"name":"E","range":"650 °C až 1000 °C","cmc":"0,51 °C"},{"name":"L","range":"-200 °C až 900 °C","cmc":"0,81 °C"},{"name":"U","range":"-200 °C až 600 °C","cmc":"0,95 °C"},{"name":"C","range":"0 °C až 1000 °C","cmc":"0,72 °C"},{"name":"C","range":"1000 °C až 2310 °C","cmc":"1,7 °C"}],"technique":"Symulacja wzorcowym kalibratorem napięcia wraz z kompensacją zimnego złącza","technique_en":"Reference voltage calibrator simulation including cold junction compensation","technique_zh":"用标准电压校准器模拟（含冷端补偿）","technique_cs":"Simulace etalonovým kalibrátorem napětí včetně kompenzace studeného spoje","techniques":["Symulacja wzorcowym kalibratorem napięcia wraz z kompensacją zimnego złącza"],"techniques_en":["Reference voltage calibrator simulation including cold junction compensation"],"techniques_zh":["用标准电压校准器模拟（含冷端补偿）"],"techniques_cs":["Simulace etalonovým kalibrátorem napětí včetně kompenzace studeného spoje"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nJ od -210 °C do -100 °C CMC 0,57 °C\nJ od -100 °C do 150 °C CMC 0,33 °C\nJ od 150 °C do 760 °C CMC 0,38 °C\nJ od 760 °C do 1200 °C CMC 0,48 °C\nK od -200 °C do -100 °C CMC 0,66 °C\nK od -100 °C do 120 °C CMC 0,40 °C\nK od 120 °C do 1370 °C CMC 0,63 °C\nT od -250 °C do -150 °C CMC 1,5 °C\nT od -150 °C do 400 °C CMC 0,37 °C\nR od 0 °C do 250 °C CMC 1,9 °C\nR od 250 °C do 1760 °C CMC 1,2 °C\nS od 0 °C do 250 °C CMC 1,9 °C\nS od 250 °C do 1760 °C CMC 1,2 °C\nB od 600 °C do 1820 °C CMC 1,8 °C\nN od -200 °C do -100 °C CMC 1,0 °C\nN od -100 °C do 410 °C CMC 0,51 °C\nN od 410 °C do 1300 °C CMC 0,59 °C\nE od -250 °C do -100 °C CMC 1,3 °C\nE od -100 °C do 650 °C CMC 0,47 °C\nE od 650 °C do 1000 °C CMC 0,51 °C\nL od -200 °C do 900 °C CMC 0,81 °C\nU od -200 °C do 600 °C CMC 0,95 °C\nC od 0 °C do 1000 °C CMC 0,72 °C\nC od 1000 °C do 2310 °C CMC 1,7 °C\nSymulacja wzorcowym kalibratorem napięcia wraz z kompensacją zimnego złącza","reference":"Kp 04-001","norm_bases":["Kp 04-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Symulacja sygnałów czujników temperatury / jednostki przetwarzające czujników temperatury Wzorcowanie – temperatura Symulacja wzorcowym kalibratorem napięcia wraz z kompensacją zimnego złącza J od -210 °C do -100 °C CMC 0,57 °C J od -100 °C do 150 °C CMC 0,33 °C J od 150 °C do 760 °C CMC 0,38 °C J od 760 °C do 1200 °C CMC 0,48 °C K od -200 °C do -100 °C CMC 0,66 °C K od -100 °C do 120 °C CMC 0,40 °C K od 120 °C do 1370 °C CMC 0,63 °C T od -250 °C do -150 °C CMC 1,5 °C T od -150 °C do 400 °C CMC 0,37 °C R od 0 °C do 250 °C CMC 1,9 °C R od 250 °C do 1760 °C CMC 1,2 °C S od 0 °C do 250 °C CMC 1,9 °C S od 250 °C do 1760 °C CMC 1,2 °C B od 600 °C do 1820 °C CMC 1,8 °C N od -200 °C do -100 °C CMC 1,0 °C N od -100 °C do 410 °C CMC 0,51 °C N od 410 °C do 1300 °C CMC 0,59 °C E od -250 °C do -100 °C CMC 1,3 °C E od -100 °C do 650 °C CMC 0,47 °C E od 650 °C do 1000 °C CMC 0,51 °C L od -200 °C do 900 °C CMC 0,81 °C U od -200 °C do 600 °C CMC 0,95 °C C od 0 °C do 1000 °C CMC 0,72 °C C od 1000 °C do 2310 °C CMC 1,7 °C Simulace signálů snímačů teploty / vyhodnocovací jednotky teplotních snímačů Kalibrace – teplota Simulace etalonovým kalibrátorem napětí včetně kompenzace studeného spoje J -210 °C až -100 °C CMC 0,57 °C J -100 °C až 150 °C CMC 0,33 °C J 150 °C až 760 °C CMC 0,38 °C J 760 °C až 1200 °C CMC 0,48 °C K -200 °C až -100 °C CMC 0,66 °C K -100 °C až 120 °C CMC 0,40 °C K 120 °C až 1370 °C CMC 0,63 °C T -250 °C až -150 °C CMC 1,5 °C T -150 °C až 400 °C CMC 0,37 °C R 0 °C až 250 °C CMC 1,9 °C R 250 °C až 1760 °C CMC 1,2 °C S 0 °C až 250 °C CMC 1,9 °C S 250 °C až 1760 °C CMC 1,2 °C B 600 °C až 1820 °C CMC 1,8 °C N -200 °C až -100 °C CMC 1,0 °C N -100 °C až 410 °C CMC 0,51 °C N 410 °C až 1300 °C CMC 0,59 °C E -250 °C až -100 °C CMC 1,3 °C E -100 °C až 650 °C CMC 0,47 °C E 650 °C až 1000 °C CMC 0,51 °C L -200 °C až 900 °C CMC 0,81 °C U -200 °C až 600 °C CMC 0,95 °C C 0 °C až 1000 °C CMC 0,72 °C C 1000 °C až 2310 °C CMC 1,7 °C Kp 04-001 Symulacja sygnalow czujnikow temperatury / jednostki przetwarzajace czujnikow temperatury Wzorcowanie – temperatura Symulacja wzorcowym kalibratorem napiecia wraz z kompensacja zimnego zlacza J od -210 °C do -100 °C CMC 0,57 °C J od -100 °C do 150 °C CMC 0,33 °C J od 150 °C do 760 °C CMC 0,38 °C J od 760 °C do 1200 °C CMC 0,48 °C K od -200 °C do -100 °C CMC 0,66 °C K od -100 °C do 120 °C CMC 0,40 °C K od 120 °C do 1370 °C CMC 0,63 °C T od -250 °C do -150 °C CMC 1,5 °C T od -150 °C do 400 °C CMC 0,37 °C R od 0 °C do 250 °C CMC 1,9 °C R od 250 °C do 1760 °C CMC 1,2 °C S od 0 °C do 250 °C CMC 1,9 °C S od 250 °C do 1760 °C CMC 1,2 °C B od 600 °C do 1820 °C CMC 1,8 °C N od -200 °C do -100 °C CMC 1,0 °C N od -100 °C do 410 °C CMC 0,51 °C N od 410 °C do 1300 °C CMC 0,59 °C E od -250 °C do -100 °C CMC 1,3 °C E od -100 °C do 650 °C CMC 0,47 °C E od 650 °C do 1000 °C CMC 0,51 °C L od -200 °C do 900 °C CMC 0,81 °C U od -200 °C do 600 °C CMC 0,95 °C C od 0 °C do 1000 °C CMC 0,72 °C C od 1000 °C do 2310 °C CMC 1,7 °C Simulace signalu snimacu teploty / vyhodnocovaci jednotky teplotnich snimacu Kalibrace – teplota Simulace etalonovym kalibratorem napeti vcetne kompenzace studeneho spoje J -210 °C az -100 °C CMC 0,57 °C J -100 °C az 150 °C CMC 0,33 °C J 150 °C az 760 °C CMC 0,38 °C J 760 °C az 1200 °C CMC 0,48 °C K -200 °C az -100 °C CMC 0,66 °C K -100 °C az 120 °C CMC 0,40 °C K 120 °C az 1370 °C CMC 0,63 °C T -250 °C az -150 °C CMC 1,5 °C T -150 °C az 400 °C CMC 0,37 °C R 0 °C az 250 °C CMC 1,9 °C R 250 °C az 1760 °C CMC 1,2 °C S 0 °C az 250 °C CMC 1,9 °C S 250 °C az 1760 °C CMC 1,2 °C B 600 °C az 1820 °C CMC 1,8 °C N -200 °C az -100 °C CMC 1,0 °C N -100 °C az 410 °C CMC 0,51 °C N 410 °C az 1300 °C CMC 0,59 °C E -250 °C az -100 °C CMC 1,3 °C E -100 °C az 650 °C CMC 0,47 °C E 650 °C az 1000 °C CMC 0,51 °C L -200 °C az 900 °C CMC 0,81 °C U -200 °C az 600 °C CMC 0,95 °C C 0 °C az 1000 °C CMC 0,72 °C C 1000 °C az 2310 °C CMC 1,7 °C Kp 04-001","search_en":"Simulation of temperature sensor signals / temperature sensor processing units Calibration – temperature Reference voltage calibrator simulation including cold junction compensation J -210 °C to -100 °C CMC 0,57 °C J -100 °C to 150 °C CMC 0,33 °C J 150 °C to 760 °C CMC 0,38 °C J 760 °C to 1200 °C CMC 0,48 °C K -200 °C to -100 °C CMC 0,66 °C K -100 °C to 120 °C CMC 0,40 °C K 120 °C to 1370 °C CMC 0,63 °C T -250 °C to -150 °C CMC 1,5 °C T -150 °C to 400 °C CMC 0,37 °C R 0 °C to 250 °C CMC 1,9 °C R 250 °C to 1760 °C CMC 1,2 °C S 0 °C to 250 °C CMC 1,9 °C S 250 °C to 1760 °C CMC 1,2 °C B 600 °C to 1820 °C CMC 1,8 °C N -200 °C to -100 °C CMC 1,0 °C N -100 °C to 410 °C CMC 0,51 °C N 410 °C to 1300 °C CMC 0,59 °C E -250 °C to -100 °C CMC 1,3 °C E -100 °C to 650 °C CMC 0,47 °C E 650 °C to 1000 °C CMC 0,51 °C L -200 °C to 900 °C CMC 0,81 °C U -200 °C to 600 °C CMC 0,95 °C C 0 °C to 1000 °C CMC 0,72 °C C 1000 °C to 2310 °C CMC 1,7 °C Kp 04-001","search_zh":"温度传感器信号的模拟 / 温度传感器处理单元 校准 – 温度 用标准电压校准器模拟（含冷端补偿） J 型 -210 °C 至 -100 °C CMC 0,57 °C J 型 -100 °C 至 150 °C CMC 0,33 °C J 型 150 °C 至 760 °C CMC 0,38 °C J 型 760 °C 至 1200 °C CMC 0,48 °C K 型 -200 °C 至 -100 °C CMC 0,66 °C K 型 -100 °C 至 120 °C CMC 0,40 °C K 型 120 °C 至 1370 °C CMC 0,63 °C T 型 -250 °C 至 -150 °C CMC 1,5 °C T 型 -150 °C 至 400 °C CMC 0,37 °C R 型 0 °C 至 250 °C CMC 1,9 °C R 型 250 °C 至 1760 °C CMC 1,2 °C S 型 0 °C 至 250 °C CMC 1,9 °C S 型 250 °C 至 1760 °C CMC 1,2 °C B 型 600 °C 至 1820 °C CMC 1,8 °C N 型 -200 °C 至 -100 °C CMC 1,0 °C N 型 -100 °C 至 410 °C CMC 0,51 °C N 型 410 °C 至 1300 °C CMC 0,59 °C E 型 -250 °C 至 -100 °C CMC 1,3 °C E 型 -100 °C 至 650 °C CMC 0,47 °C E 型 650 °C 至 1000 °C CMC 0,51 °C L 型 -200 °C 至 900 °C CMC 0,81 °C U 型 -200 °C 至 600 °C CMC 0,95 °C C 型 0 °C 至 1000 °C CMC 0,72 °C C 型 1000 °C 至 2310 °C CMC 1,7 °C Kp 04-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"82a89681ccf11735ebcdb48f","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"3","test_object":"Symulacja sygnałów czujników temperatury / jednostki przetwarzające czujników temperatury","test_object_en":"Simulation of temperature sensor signals / temperature sensor processing units","test_object_zh":"温度传感器信号的模拟 / 温度传感器处理单元","test_object_cs":"Simulace signálů snímačů teploty / vyhodnocovací jednotky teplotních snímačů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"RTD","range":"od -200 °C do 0 °C","cmc":"0,35 °C"},{"name":"RTD","range":"od 0 °C do 800 °C","cmc":"0,58 °C"}],"parameters_en":[{"name":"RTD","range":"-200 °C to 0 °C","cmc":"0,35 °C"},{"name":"RTD","range":"0 °C to 800 °C","cmc":"0,58 °C"}],"parameters_zh":[{"name":"RTD（电阻温度传感器）","range":"-200 °C 至 0 °C","cmc":"0,35 °C"},{"name":"RTD（电阻温度传感器）","range":"0 °C 至 800 °C","cmc":"0,58 °C"}],"parameters_cs":[{"name":"RTD","range":"-200 °C až 0 °C","cmc":"0,35 °C"},{"name":"RTD","range":"0 °C až 800 °C","cmc":"0,58 °C"}],"technique":"Symulacja wzorcowym kalibratorem rezystancji","technique_en":"Reference resistance calibrator simulation","technique_zh":"用标准电阻校准器模拟","technique_cs":"Simulace etalonovým kalibrátorem odporu","techniques":["Symulacja wzorcowym kalibratorem rezystancji"],"techniques_en":["Reference resistance calibrator simulation"],"techniques_zh":["用标准电阻校准器模拟"],"techniques_cs":["Simulace etalonovým kalibrátorem odporu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nRTD od -200 °C do 0 °C CMC 0,35 °C\nRTD od 0 °C do 800 °C CMC 0,58 °C\nSymulacja wzorcowym kalibratorem rezystancji","reference":"Kp 04-001","norm_bases":["Kp 04-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Symulacja sygnałów czujników temperatury / jednostki przetwarzające czujników temperatury Wzorcowanie – temperatura Symulacja wzorcowym kalibratorem rezystancji RTD od -200 °C do 0 °C CMC 0,35 °C RTD od 0 °C do 800 °C CMC 0,58 °C Simulace signálů snímačů teploty / vyhodnocovací jednotky teplotních snímačů Kalibrace – teplota Simulace etalonovým kalibrátorem odporu RTD -200 °C až 0 °C CMC 0,35 °C RTD 0 °C až 800 °C CMC 0,58 °C Kp 04-001 Symulacja sygnalow czujnikow temperatury / jednostki przetwarzajace czujnikow temperatury Wzorcowanie – temperatura Symulacja wzorcowym kalibratorem rezystancji RTD od -200 °C do 0 °C CMC 0,35 °C RTD od 0 °C do 800 °C CMC 0,58 °C Simulace signalu snimacu teploty / vyhodnocovaci jednotky teplotnich snimacu Kalibrace – teplota Simulace etalonovym kalibratorem odporu RTD -200 °C az 0 °C CMC 0,35 °C RTD 0 °C az 800 °C CMC 0,58 °C Kp 04-001","search_en":"Simulation of temperature sensor signals / temperature sensor processing units Calibration – temperature Reference resistance calibrator simulation RTD -200 °C to 0 °C CMC 0,35 °C RTD 0 °C to 800 °C CMC 0,58 °C Kp 04-001","search_zh":"温度传感器信号的模拟 / 温度传感器处理单元 校准 – 温度 用标准电阻校准器模拟 RTD（电阻温度传感器） -200 °C 至 0 °C CMC 0,35 °C RTD（电阻温度传感器） 0 °C 至 800 °C CMC 0,58 °C Kp 04-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1aacb236630605d1148a1dfe","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / Źródła napięcia stałego","test_object_en":"Direct-current voltage / DC voltage sources","test_object_zh":"直流电压 / 直流电压源","test_object_cs":"Stejnosměrné napětí / Zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,0037 % + 13 µV"},{"name":"","range":"od 0,1 V do 1 V","cmc":"0,0025 % + 37 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,0024 % + 0,36 mV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,0038 % + 3,6 mV"},{"name":"","range":"od 100 V do 1000 V","cmc":"0,0041 % + 36 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,0037 % + 13 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"0,0025 % + 37 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0024 % + 0,36 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,0038 % + 3,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"0,0041 % + 36 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,0037 % + 13 µV"},{"name":"","range":"0,1 V 至 1 V","cmc":"0,0025 % + 37 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,0024 % + 0,36 mV"},{"name":"","range":"10 V 至 100 V","cmc":"0,0038 % + 3,6 mV"},{"name":"","range":"100 V 至 1000 V","cmc":"0,0041 % + 36 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,0037 % + 13 µV"},{"name":"","range":"0,1 V až 1 V","cmc":"0,0025 % + 37 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,0024 % + 0,36 mV"},{"name":"","range":"10 V až 100 V","cmc":"0,0038 % + 3,6 mV"},{"name":"","range":"100 V až 1000 V","cmc":"0,0041 % + 36 mV"}],"technique":"Bezpośredni pomiar multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Bezpośredni pomiar multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,0037 % + 13 µV\nod 0,1 V do 1 V CMC 0,0025 % + 37 µV\nod 1 V do 10 V CMC 0,0024 % + 0,36 mV\nod 10 V do 100 V CMC 0,0038 % + 3,6 mV\nod 100 V do 1000 V CMC 0,0041 % + 36 mV\nBezpośredni pomiar multimetrem wzorcowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / Źródła napięcia stałego Wzorcowanie – wielkości elektryczne Bezpośredni pomiar multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0037 % + 13 µV od 0,1 V do 1 V CMC 0,0025 % + 37 µV od 1 V do 10 V CMC 0,0024 % + 0,36 mV od 10 V do 100 V CMC 0,0038 % + 3,6 mV od 100 V do 1000 V CMC 0,0041 % + 36 mV Stejnosměrné napětí / Zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 mV až 100 mV CMC 0,0037 % + 13 µV 0,1 V až 1 V CMC 0,0025 % + 37 µV 1 V až 10 V CMC 0,0024 % + 0,36 mV 10 V až 100 V CMC 0,0038 % + 3,6 mV 100 V až 1000 V CMC 0,0041 % + 36 mV Kp 04-001, Kp 04-003 Napiecie stale / Zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Bezposredni pomiar multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0037 % + 13 µV od 0,1 V do 1 V CMC 0,0025 % + 37 µV od 1 V do 10 V CMC 0,0024 % + 0,36 mV od 10 V do 100 V CMC 0,0038 % + 3,6 mV od 100 V do 1000 V CMC 0,0041 % + 36 mV Stejnosmerne napeti / Zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 mV az 100 mV CMC 0,0037 % + 13 µV 0,1 V az 1 V CMC 0,0025 % + 37 µV 1 V az 10 V CMC 0,0024 % + 0,36 mV 10 V az 100 V CMC 0,0038 % + 3,6 mV 100 V az 1000 V CMC 0,0041 % + 36 mV Kp 04-001, Kp 04-003","search_en":"Direct-current voltage / DC voltage sources Calibration – electrical quantities Direct measurement by a reference multimeter 0 mV to 100 mV CMC 0,0037 % + 13 µV 0,1 V to 1 V CMC 0,0025 % + 37 µV 1 V to 10 V CMC 0,0024 % + 0,36 mV 10 V to 100 V CMC 0,0038 % + 3,6 mV 100 V to 1000 V CMC 0,0041 % + 36 mV Kp 04-001, Kp 04-003","search_zh":"直流电压 / 直流电压源 校准 – 电学量 用标准万用表直接测量 0 mV 至 100 mV CMC 0,0037 % + 13 µV 0,1 V 至 1 V CMC 0,0025 % + 37 µV 1 V 至 10 V CMC 0,0024 % + 0,36 mV 10 V 至 100 V CMC 0,0038 % + 3,6 mV 100 V 至 1000 V CMC 0,0041 % + 36 mV Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"04be9cc7a2017049446baee2","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / Źródła napięcia stałego","test_object_en":"Direct-current voltage / DC voltage sources","test_object_zh":"直流电压 / 直流电压源","test_object_cs":"Stejnosměrné napětí / Zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 kV do 3 kV","cmc":"0,5 % + 0,037 kV"},{"name":"","range":"od 3 kV do 10 kV","cmc":"0,5 % + 0,049 kV"}],"parameters_en":[{"name":"","range":"1 kV to 3 kV","cmc":"0,5 % + 0,037 kV"},{"name":"","range":"3 kV to 10 kV","cmc":"0,5 % + 0,049 kV"}],"parameters_zh":[{"name":"","range":"1 kV 至 3 kV","cmc":"0,5 % + 0,037 kV"},{"name":"","range":"3 kV 至 10 kV","cmc":"0,5 % + 0,049 kV"}],"parameters_cs":[{"name":"","range":"1 kV až 3 kV","cmc":"0,5 % + 0,037 kV"},{"name":"","range":"3 kV až 10 kV","cmc":"0,5 % + 0,049 kV"}],"technique":"Pośredni pomiar kalibratorem wzorcowym z adapterem Hipot","technique_en":"Indirect measurement with a reference calibrator with a Hipot adapter","technique_zh":"用带 Hipot 适配器的标准校准器间接测量","technique_cs":"Nepřímé měření etalonovým kalibrátorem s Hipot adaptérem","techniques":["Pośredni pomiar kalibratorem wzorcowym z adapterem Hipot"],"techniques_en":["Indirect measurement with a reference calibrator with a Hipot adapter"],"techniques_zh":["用带 Hipot 适配器的标准校准器间接测量"],"techniques_cs":["Nepřímé měření etalonovým kalibrátorem s Hipot adaptérem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 kV do 3 kV CMC 0,5 % + 0,037 kV\nod 3 kV do 10 kV CMC 0,5 % + 0,049 kV\nPośredni pomiar kalibratorem wzorcowym z adapterem Hipot","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / Źródła napięcia stałego Wzorcowanie – wielkości elektryczne Pośredni pomiar kalibratorem wzorcowym z adapterem Hipot od 1 kV do 3 kV CMC 0,5 % + 0,037 kV od 3 kV do 10 kV CMC 0,5 % + 0,049 kV Stejnosměrné napětí / Zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Nepřímé měření etalonovým kalibrátorem s Hipot adaptérem 1 kV až 3 kV CMC 0,5 % + 0,037 kV 3 kV až 10 kV CMC 0,5 % + 0,049 kV Kp 04-001, Kp 04-003 Napiecie stale / Zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Posredni pomiar kalibratorem wzorcowym z adapterem Hipot od 1 kV do 3 kV CMC 0,5 % + 0,037 kV od 3 kV do 10 kV CMC 0,5 % + 0,049 kV Stejnosmerne napeti / Zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Neprime mereni etalonovym kalibratorem s Hipot adapterem 1 kV az 3 kV CMC 0,5 % + 0,037 kV 3 kV az 10 kV CMC 0,5 % + 0,049 kV Kp 04-001, Kp 04-003","search_en":"Direct-current voltage / DC voltage sources Calibration – electrical quantities Indirect measurement with a reference calibrator with a Hipot adapter 1 kV to 3 kV CMC 0,5 % + 0,037 kV 3 kV to 10 kV CMC 0,5 % + 0,049 kV Kp 04-001, Kp 04-003","search_zh":"直流电压 / 直流电压源 校准 – 电学量 用带 Hipot 适配器的标准校准器间接测量 1 kV 至 3 kV CMC 0,5 % + 0,037 kV 3 kV 至 10 kV CMC 0,5 % + 0,049 kV Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4ea1cdf3d834f86f2837e3bf","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / Mierniki napięcia stałego","test_object_en":"Direct-current voltage / DC voltage meters","test_object_zh":"直流电压 / 直流电压表","test_object_cs":"Stejnosměrné napětí / Měřidla stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,008 % + 12 µV"},{"name":"","range":"od 0,1 V do 1 V","cmc":"0,008 % + 35 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,008 % + 0,35 mV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,008 % + 3,5 mV"},{"name":"","range":"od 100 V do 1000 V","cmc":"0,008 % + 35 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,008 % + 12 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"0,008 % + 35 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,008 % + 0,35 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,008 % + 3,5 mV"},{"name":"","range":"100 V to 1000 V","cmc":"0,008 % + 35 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,008 % + 12 µV"},{"name":"","range":"0,1 V 至 1 V","cmc":"0,008 % + 35 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,008 % + 0,35 mV"},{"name":"","range":"10 V 至 100 V","cmc":"0,008 % + 3,5 mV"},{"name":"","range":"100 V 至 1000 V","cmc":"0,008 % + 35 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,008 % + 12 µV"},{"name":"","range":"0,1 V až 1 V","cmc":"0,008 % + 35 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,008 % + 0,35 mV"},{"name":"","range":"10 V až 100 V","cmc":"0,008 % + 3,5 mV"},{"name":"","range":"100 V až 1000 V","cmc":"0,008 % + 35 mV"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a reference calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a reference calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,008 % + 12 µV\nod 0,1 V do 1 V CMC 0,008 % + 35 µV\nod 1 V do 10 V CMC 0,008 % + 0,35 mV\nod 10 V do 100 V CMC 0,008 % + 3,5 mV\nod 100 V do 1000 V CMC 0,008 % + 35 mV\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / Mierniki napięcia stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym od 0 mV do 100 mV CMC 0,008 % + 12 µV od 0,1 V do 1 V CMC 0,008 % + 35 µV od 1 V do 10 V CMC 0,008 % + 0,35 mV od 10 V do 100 V CMC 0,008 % + 3,5 mV od 100 V do 1000 V CMC 0,008 % + 35 mV Stejnosměrné napětí / Měřidla stejnosměrného napětí Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 0 mV až 100 mV CMC 0,008 % + 12 µV 0,1 V až 1 V CMC 0,008 % + 35 µV 1 V až 10 V CMC 0,008 % + 0,35 mV 10 V až 100 V CMC 0,008 % + 3,5 mV 100 V až 1000 V CMC 0,008 % + 35 mV Kp 04-001, Kp 04-003 Napiecie stale / Mierniki napiecia stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym od 0 mV do 100 mV CMC 0,008 % + 12 µV od 0,1 V do 1 V CMC 0,008 % + 35 µV od 1 V do 10 V CMC 0,008 % + 0,35 mV od 10 V do 100 V CMC 0,008 % + 3,5 mV od 100 V do 1000 V CMC 0,008 % + 35 mV Stejnosmerne napeti / Meridla stejnosmerneho napeti Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 0 mV az 100 mV CMC 0,008 % + 12 µV 0,1 V az 1 V CMC 0,008 % + 35 µV 1 V az 10 V CMC 0,008 % + 0,35 mV 10 V az 100 V CMC 0,008 % + 3,5 mV 100 V az 1000 V CMC 0,008 % + 35 mV Kp 04-001, Kp 04-003","search_en":"Direct-current voltage / DC voltage meters Calibration – electrical quantities Direct generation with a reference calibrator 0 mV to 100 mV CMC 0,008 % + 12 µV 0,1 V to 1 V CMC 0,008 % + 35 µV 1 V to 10 V CMC 0,008 % + 0,35 mV 10 V to 100 V CMC 0,008 % + 3,5 mV 100 V to 1000 V CMC 0,008 % + 35 mV Kp 04-001, Kp 04-003","search_zh":"直流电压 / 直流电压表 校准 – 电学量 用标准校准器直接产生 0 mV 至 100 mV CMC 0,008 % + 12 µV 0,1 V 至 1 V CMC 0,008 % + 35 µV 1 V 至 10 V CMC 0,008 % + 0,35 mV 10 V 至 100 V CMC 0,008 % + 3,5 mV 100 V 至 1000 V CMC 0,008 % + 35 mV Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2ba141dd778612600fff3bf9","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / Źródła prądu stałego","test_object_en":"Direct current / Direct current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / Zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 100 µA","cmc":"0,05 % + 37 nA"},{"name":"","range":"od 0,1 mA do 1 mA","cmc":"0,05 % + 0,12 µA"},{"name":"","range":"od 1 mA do 10 mA","cmc":"0,05 % + 2,5 µA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,05 % + 14 µA"},{"name":"","range":"od 100 mA do 400 mA","cmc":"0,05 % + 73 µA"},{"name":"","range":"od 0,4 A do 1 A","cmc":"0,05 % + 0,3 mA"},{"name":"","range":"od 1 A do 3 A","cmc":"0,10 % + 0,8 mA"},{"name":"","range":"od 3 A do 10 A","cmc":"0,15 % + 1,6 mA"}],"parameters_en":[{"name":"","range":"0 µA to 100 µA","cmc":"0,05 % + 37 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"0,05 % + 0,12 µA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,05 % + 2,5 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,05 % + 14 µA"},{"name":"","range":"100 mA to 400 mA","cmc":"0,05 % + 73 µA"},{"name":"","range":"0,4 A to 1 A","cmc":"0,05 % + 0,3 mA"},{"name":"","range":"1 A to 3 A","cmc":"0,10 % + 0,8 mA"},{"name":"","range":"3 A to 10 A","cmc":"0,15 % + 1,6 mA"}],"parameters_zh":[{"name":"","range":"0 µA 至 100 µA","cmc":"0,05 % + 37 nA"},{"name":"","range":"0,1 mA 至 1 mA","cmc":"0,05 % + 0,12 µA"},{"name":"","range":"1 mA 至 10 mA","cmc":"0,05 % + 2,5 µA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,05 % + 14 µA"},{"name":"","range":"100 mA 至 400 mA","cmc":"0,05 % + 73 µA"},{"name":"","range":"0,4 A 至 1 A","cmc":"0,05 % + 0,3 mA"},{"name":"","range":"1 A 至 3 A","cmc":"0,10 % + 0,8 mA"},{"name":"","range":"3 A 至 10 A","cmc":"0,15 % + 1,6 mA"}],"parameters_cs":[{"name":"","range":"0 µA až 100 µA","cmc":"0,05 % + 37 nA"},{"name":"","range":"0,1 mA až 1 mA","cmc":"0,05 % + 0,12 µA"},{"name":"","range":"1 mA až 10 mA","cmc":"0,05 % + 2,5 µA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,05 % + 14 µA"},{"name":"","range":"100 mA až 400 mA","cmc":"0,05 % + 73 µA"},{"name":"","range":"0,4 A až 1 A","cmc":"0,05 % + 0,3 mA"},{"name":"","range":"1 A až 3 A","cmc":"0,10 % + 0,8 mA"},{"name":"","range":"3 A až 10 A","cmc":"0,15 % + 1,6 mA"}],"technique":"Bezpośredni pomiar multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Bezpośredni pomiar multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 100 µA CMC 0,05 % + 37 nA\nod 0,1 mA do 1 mA CMC 0,05 % + 0,12 µA\nod 1 mA do 10 mA CMC 0,05 % + 2,5 µA\nod 10 mA do 100 mA CMC 0,05 % + 14 µA\nod 100 mA do 400 mA CMC 0,05 % + 73 µA\nod 0,4 A do 1 A CMC 0,05 % + 0,3 mA\nod 1 A do 3 A CMC 0,10 % + 0,8 mA\nod 3 A do 10 A CMC 0,15 % + 1,6 mA\nBezpośredni pomiar multimetrem wzorcowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Źródła prądu stałego Wzorcowanie – wielkości elektryczne Bezpośredni pomiar multimetrem wzorcowym od 0 µA do 100 µA CMC 0,05 % + 37 nA od 0,1 mA do 1 mA CMC 0,05 % + 0,12 µA od 1 mA do 10 mA CMC 0,05 % + 2,5 µA od 10 mA do 100 mA CMC 0,05 % + 14 µA od 100 mA do 400 mA CMC 0,05 % + 73 µA od 0,4 A do 1 A CMC 0,05 % + 0,3 mA od 1 A do 3 A CMC 0,10 % + 0,8 mA od 3 A do 10 A CMC 0,15 % + 1,6 mA Stejnosměrný proud / Zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 µA až 100 µA CMC 0,05 % + 37 nA 0,1 mA až 1 mA CMC 0,05 % + 0,12 µA 1 mA až 10 mA CMC 0,05 % + 2,5 µA 10 mA až 100 mA CMC 0,05 % + 14 µA 100 mA až 400 mA CMC 0,05 % + 73 µA 0,4 A až 1 A CMC 0,05 % + 0,3 mA 1 A až 3 A CMC 0,10 % + 0,8 mA 3 A až 10 A CMC 0,15 % + 1,6 mA Kp 04-001, Kp 04-003 Prad staly / Zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Bezposredni pomiar multimetrem wzorcowym od 0 µA do 100 µA CMC 0,05 % + 37 nA od 0,1 mA do 1 mA CMC 0,05 % + 0,12 µA od 1 mA do 10 mA CMC 0,05 % + 2,5 µA od 10 mA do 100 mA CMC 0,05 % + 14 µA od 100 mA do 400 mA CMC 0,05 % + 73 µA od 0,4 A do 1 A CMC 0,05 % + 0,3 mA od 1 A do 3 A CMC 0,10 % + 0,8 mA od 3 A do 10 A CMC 0,15 % + 1,6 mA Stejnosmerny proud / Zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 µA az 100 µA CMC 0,05 % + 37 nA 0,1 mA az 1 mA CMC 0,05 % + 0,12 µA 1 mA az 10 mA CMC 0,05 % + 2,5 µA 10 mA az 100 mA CMC 0,05 % + 14 µA 100 mA az 400 mA CMC 0,05 % + 73 µA 0,4 A az 1 A CMC 0,05 % + 0,3 mA 1 A az 3 A CMC 0,10 % + 0,8 mA 3 A az 10 A CMC 0,15 % + 1,6 mA Kp 04-001, Kp 04-003","search_en":"Direct current / Direct current sources Calibration – electrical quantities Direct measurement by a reference multimeter 0 µA to 100 µA CMC 0,05 % + 37 nA 0,1 mA to 1 mA CMC 0,05 % + 0,12 µA 1 mA to 10 mA CMC 0,05 % + 2,5 µA 10 mA to 100 mA CMC 0,05 % + 14 µA 100 mA to 400 mA CMC 0,05 % + 73 µA 0,4 A to 1 A CMC 0,05 % + 0,3 mA 1 A to 3 A CMC 0,10 % + 0,8 mA 3 A to 10 A CMC 0,15 % + 1,6 mA Kp 04-001, Kp 04-003","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用标准万用表直接测量 0 µA 至 100 µA CMC 0,05 % + 37 nA 0,1 mA 至 1 mA CMC 0,05 % + 0,12 µA 1 mA 至 10 mA CMC 0,05 % + 2,5 µA 10 mA 至 100 mA CMC 0,05 % + 14 µA 100 mA 至 400 mA CMC 0,05 % + 73 µA 0,4 A 至 1 A CMC 0,05 % + 0,3 mA 1 A 至 3 A CMC 0,10 % + 0,8 mA 3 A 至 10 A CMC 0,15 % + 1,6 mA Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"acd12f000f4e8ba498b1f9a9","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / Źródła prądu stałego","test_object_en":"Direct current / Direct current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / Zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 A do 40 A","cmc":"2,8 % + 0,52 A"},{"name":"","range":"od 40 A do 400 A","cmc":"2,8 % + 2,8 A"}],"parameters_en":[{"name":"","range":"0 A to 40 A","cmc":"2,8 % + 0,52 A"},{"name":"","range":"40 A to 400 A","cmc":"2,8 % + 2,8 A"}],"parameters_zh":[{"name":"","range":"0 A 至 40 A","cmc":"2,8 % + 0,52 A"},{"name":"","range":"40 A 至 400 A","cmc":"2,8 % + 2,8 A"}],"parameters_cs":[{"name":"","range":"0 A až 40 A","cmc":"2,8 % + 0,52 A"},{"name":"","range":"40 A až 400 A","cmc":"2,8 % + 2,8 A"}],"technique":"Bezpośredni pomiar wzorcowym multimetrem cęgowym","technique_en":"Direct measurement by a reference clamp multimeter","technique_zh":"用标准钳形万用表直接测量","technique_cs":"Přímé měření etalonovým klešťovým multimetrem","techniques":["Bezpośredni pomiar wzorcowym multimetrem cęgowym"],"techniques_en":["Direct measurement by a reference clamp multimeter"],"techniques_zh":["用标准钳形万用表直接测量"],"techniques_cs":["Přímé měření etalonovým klešťovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 A do 40 A CMC 2,8 % + 0,52 A\nod 40 A do 400 A CMC 2,8 % + 2,8 A\nBezpośredni pomiar wzorcowym multimetrem cęgowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Źródła prądu stałego Wzorcowanie – wielkości elektryczne Bezpośredni pomiar wzorcowym multimetrem cęgowym od 0 A do 40 A CMC 2,8 % + 0,52 A od 40 A do 400 A CMC 2,8 % + 2,8 A Stejnosměrný proud / Zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření etalonovým klešťovým multimetrem 0 A až 40 A CMC 2,8 % + 0,52 A 40 A až 400 A CMC 2,8 % + 2,8 A Kp 04-001, Kp 04-003 Prad staly / Zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Bezposredni pomiar wzorcowym multimetrem cegowym od 0 A do 40 A CMC 2,8 % + 0,52 A od 40 A do 400 A CMC 2,8 % + 2,8 A Stejnosmerny proud / Zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym klestovym multimetrem 0 A az 40 A CMC 2,8 % + 0,52 A 40 A az 400 A CMC 2,8 % + 2,8 A Kp 04-001, Kp 04-003","search_en":"Direct current / Direct current sources Calibration – electrical quantities Direct measurement by a reference clamp multimeter 0 A to 40 A CMC 2,8 % + 0,52 A 40 A to 400 A CMC 2,8 % + 2,8 A Kp 04-001, Kp 04-003","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用标准钳形万用表直接测量 0 A 至 40 A CMC 2,8 % + 0,52 A 40 A 至 400 A CMC 2,8 % + 2,8 A Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ded28c1bec665f97c81992b4","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / Źródła prądu stałego","test_object_en":"Direct current / Direct current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / Zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 A do 100 A","cmc":"0,2 % + 0,013 A"},{"name":"","range":"od 100 A do 200 A","cmc":"0,2 % + 0,035 A"}],"parameters_en":[{"name":"","range":"10 A to 100 A","cmc":"0,2 % + 0,013 A"},{"name":"","range":"100 A to 200 A","cmc":"0,2 % + 0,035 A"}],"parameters_zh":[{"name":"","range":"10 A 至 100 A","cmc":"0,2 % + 0,013 A"},{"name":"","range":"100 A 至 200 A","cmc":"0,2 % + 0,035 A"}],"parameters_cs":[{"name":"","range":"10 A až 100 A","cmc":"0,2 % + 0,013 A"},{"name":"","range":"100 A až 200 A","cmc":"0,2 % + 0,035 A"}],"technique":"Pośredni pomiar bocznikiem wzorcowym i multimetrem","technique_en":"Indirect measurement using a reference shunt and multimeter","technique_zh":"用标准分流器和万用表间接测量","technique_cs":"Nepřímé měření etalonovým bočníkem a multimetrem","techniques":["Pośredni pomiar bocznikiem wzorcowym i multimetrem"],"techniques_en":["Indirect measurement using a reference shunt and multimeter"],"techniques_zh":["用标准分流器和万用表间接测量"],"techniques_cs":["Nepřímé měření etalonovým bočníkem a multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 10 A do 100 A CMC 0,2 % + 0,013 A\nod 100 A do 200 A CMC 0,2 % + 0,035 A\nPośredni pomiar bocznikiem wzorcowym i multimetrem","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Źródła prądu stałego Wzorcowanie – wielkości elektryczne Pośredni pomiar bocznikiem wzorcowym i multimetrem od 10 A do 100 A CMC 0,2 % + 0,013 A od 100 A do 200 A CMC 0,2 % + 0,035 A Stejnosměrný proud / Zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Nepřímé měření etalonovým bočníkem a multimetrem 10 A až 100 A CMC 0,2 % + 0,013 A 100 A až 200 A CMC 0,2 % + 0,035 A Kp 04-001, Kp 04-003 Prad staly / Zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Posredni pomiar bocznikiem wzorcowym i multimetrem od 10 A do 100 A CMC 0,2 % + 0,013 A od 100 A do 200 A CMC 0,2 % + 0,035 A Stejnosmerny proud / Zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Neprime mereni etalonovym bocnikem a multimetrem 10 A az 100 A CMC 0,2 % + 0,013 A 100 A az 200 A CMC 0,2 % + 0,035 A Kp 04-001, Kp 04-003","search_en":"Direct current / Direct current sources Calibration – electrical quantities Indirect measurement using a reference shunt and multimeter 10 A to 100 A CMC 0,2 % + 0,013 A 100 A to 200 A CMC 0,2 % + 0,035 A Kp 04-001, Kp 04-003","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用标准分流器和万用表间接测量 10 A 至 100 A CMC 0,2 % + 0,013 A 100 A 至 200 A CMC 0,2 % + 0,035 A Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8fb4980e8b037a7ff9ec1d0e","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / Mierniki prądu stałego","test_object_en":"Direct current / Direct current meters","test_object_zh":"直流电流 / 直流电流表","test_object_cs":"Stejnosměrný proud / Měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 100 µA","cmc":"0,03 % + 35 nA"},{"name":"","range":"od 0,1 mA do 1 mA","cmc":"0,03 % + 0,12 µA"},{"name":"","range":"od 1 mA do 10 mA","cmc":"0,03 % + 1,2 µA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,03 % + 12 µA"},{"name":"","range":"od 0,1 A do 1 A","cmc":"0,03 % + 0,18 mA"},{"name":"","range":"od 1 A do 10 A","cmc":"0,05 % + 2,4 mA"}],"parameters_en":[{"name":"","range":"0 µA to 100 µA","cmc":"0,03 % + 35 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"0,03 % + 0,12 µA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,03 % + 1,2 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,03 % + 12 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"0,03 % + 0,18 mA"},{"name":"","range":"1 A to 10 A","cmc":"0,05 % + 2,4 mA"}],"parameters_zh":[{"name":"","range":"0 µA 至 100 µA","cmc":"0,03 % + 35 nA"},{"name":"","range":"0,1 mA 至 1 mA","cmc":"0,03 % + 0,12 µA"},{"name":"","range":"1 mA 至 10 mA","cmc":"0,03 % + 1,2 µA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,03 % + 12 µA"},{"name":"","range":"0,1 A 至 1 A","cmc":"0,03 % + 0,18 mA"},{"name":"","range":"1 A 至 10 A","cmc":"0,05 % + 2,4 mA"}],"parameters_cs":[{"name":"","range":"0 µA až 100 µA","cmc":"0,03 % + 35 nA"},{"name":"","range":"0,1 mA až 1 mA","cmc":"0,03 % + 0,12 µA"},{"name":"","range":"1 mA až 10 mA","cmc":"0,03 % + 1,2 µA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,03 % + 12 µA"},{"name":"","range":"0,1 A až 1 A","cmc":"0,03 % + 0,18 mA"},{"name":"","range":"1 A až 10 A","cmc":"0,05 % + 2,4 mA"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a reference calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a reference calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 100 µA CMC 0,03 % + 35 nA\nod 0,1 mA do 1 mA CMC 0,03 % + 0,12 µA\nod 1 mA do 10 mA CMC 0,03 % + 1,2 µA\nod 10 mA do 100 mA CMC 0,03 % + 12 µA\nod 0,1 A do 1 A CMC 0,03 % + 0,18 mA\nod 1 A do 10 A CMC 0,05 % + 2,4 mA\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Mierniki prądu stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym od 0 µA do 100 µA CMC 0,03 % + 35 nA od 0,1 mA do 1 mA CMC 0,03 % + 0,12 µA od 1 mA do 10 mA CMC 0,03 % + 1,2 µA od 10 mA do 100 mA CMC 0,03 % + 12 µA od 0,1 A do 1 A CMC 0,03 % + 0,18 mA od 1 A do 10 A CMC 0,05 % + 2,4 mA Stejnosměrný proud / Měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 0 µA až 100 µA CMC 0,03 % + 35 nA 0,1 mA až 1 mA CMC 0,03 % + 0,12 µA 1 mA až 10 mA CMC 0,03 % + 1,2 µA 10 mA až 100 mA CMC 0,03 % + 12 µA 0,1 A až 1 A CMC 0,03 % + 0,18 mA 1 A až 10 A CMC 0,05 % + 2,4 mA Kp 04-001, Kp 04-003 Prad staly / Mierniki pradu stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym od 0 µA do 100 µA CMC 0,03 % + 35 nA od 0,1 mA do 1 mA CMC 0,03 % + 0,12 µA od 1 mA do 10 mA CMC 0,03 % + 1,2 µA od 10 mA do 100 mA CMC 0,03 % + 12 µA od 0,1 A do 1 A CMC 0,03 % + 0,18 mA od 1 A do 10 A CMC 0,05 % + 2,4 mA Stejnosmerny proud / Meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 0 µA az 100 µA CMC 0,03 % + 35 nA 0,1 mA az 1 mA CMC 0,03 % + 0,12 µA 1 mA az 10 mA CMC 0,03 % + 1,2 µA 10 mA az 100 mA CMC 0,03 % + 12 µA 0,1 A az 1 A CMC 0,03 % + 0,18 mA 1 A az 10 A CMC 0,05 % + 2,4 mA Kp 04-001, Kp 04-003","search_en":"Direct current / Direct current meters Calibration – electrical quantities Direct generation with a reference calibrator 0 µA to 100 µA CMC 0,03 % + 35 nA 0,1 mA to 1 mA CMC 0,03 % + 0,12 µA 1 mA to 10 mA CMC 0,03 % + 1,2 µA 10 mA to 100 mA CMC 0,03 % + 12 µA 0,1 A to 1 A CMC 0,03 % + 0,18 mA 1 A to 10 A CMC 0,05 % + 2,4 mA Kp 04-001, Kp 04-003","search_zh":"直流电流 / 直流电流表 校准 – 电学量 用标准校准器直接产生 0 µA 至 100 µA CMC 0,03 % + 35 nA 0,1 mA 至 1 mA CMC 0,03 % + 0,12 µA 1 mA 至 10 mA CMC 0,03 % + 1,2 µA 10 mA 至 100 mA CMC 0,03 % + 12 µA 0,1 A 至 1 A CMC 0,03 % + 0,18 mA 1 A 至 10 A CMC 0,05 % + 2,4 mA Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca5e9459368a3d0ff7d17055","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / Mierniki prądu stałego","test_object_en":"Direct current / Direct current meters","test_object_zh":"直流电流 / 直流电流表","test_object_cs":"Stejnosměrný proud / Měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 A do 50 A","cmc":"0,2 %+ 0,013 A"}],"parameters_en":[{"name":"","range":"10 A to 50 A","cmc":"0,2 %+ 0,013 A"}],"parameters_zh":[{"name":"","range":"10 A 至 50 A","cmc":"0,2 %+ 0,013 A"}],"parameters_cs":[{"name":"","range":"10 A až 50 A","cmc":"0,2 %+ 0,013 A"}],"technique":"Pośrednie porównanie z bocznikiem wzorcowym i multimetrem","technique_en":"Indirect comparison with a reference shunt and multimeter","technique_zh":"与标准分流器和万用表间接比较","technique_cs":"Nepřímé porovnání s etalonovým bočníkem a multimetrem","techniques":["Pośrednie porównanie z bocznikiem wzorcowym i multimetrem"],"techniques_en":["Indirect comparison with a reference shunt and multimeter"],"techniques_zh":["与标准分流器和万用表间接比较"],"techniques_cs":["Nepřímé porovnání s etalonovým bočníkem a multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 10 A do 50 A CMC 0,2 %+ 0,013 A\nPośrednie porównanie z bocznikiem wzorcowym i multimetrem","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Mierniki prądu stałego Wzorcowanie – wielkości elektryczne Pośrednie porównanie z bocznikiem wzorcowym i multimetrem od 10 A do 50 A CMC 0,2 %+ 0,013 A Stejnosměrný proud / Měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Nepřímé porovnání s etalonovým bočníkem a multimetrem 10 A až 50 A CMC 0,2 %+ 0,013 A Kp 04-001, Kp 04-003 Prad staly / Mierniki pradu stalego Wzorcowanie – wielkosci elektryczne Posrednie porownanie z bocznikiem wzorcowym i multimetrem od 10 A do 50 A CMC 0,2 %+ 0,013 A Stejnosmerny proud / Meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Neprime porovnani s etalonovym bocnikem a multimetrem 10 A az 50 A CMC 0,2 %+ 0,013 A Kp 04-001, Kp 04-003","search_en":"Direct current / Direct current meters Calibration – electrical quantities Indirect comparison with a reference shunt and multimeter 10 A to 50 A CMC 0,2 %+ 0,013 A Kp 04-001, Kp 04-003","search_zh":"直流电流 / 直流电流表 校准 – 电学量 与标准分流器和万用表间接比较 10 A 至 50 A CMC 0,2 %+ 0,013 A Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1903fd9ec9836cdc191f2b3","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / Mierniki prądu stałego","test_object_en":"Direct current / Direct current meters","test_object_zh":"直流电流 / 直流电流表","test_object_cs":"Stejnosměrný proud / Měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 A do 20 A","cmc":"0,56 % + 0,13 A"},{"name":"","range":"od 20 A do 100 A","cmc":"0,65 % + 0,17 A"},{"name":"","range":"od 100 A do 500 A","cmc":"0,53 % + 0,52 A"}],"parameters_en":[{"name":"","range":"0 A to 20 A","cmc":"0,56 % + 0,13 A"},{"name":"","range":"20 A to 100 A","cmc":"0,65 % + 0,17 A"},{"name":"","range":"100 A to 500 A","cmc":"0,53 % + 0,52 A"}],"parameters_zh":[{"name":"","range":"0 A 至 20 A","cmc":"0,56 % + 0,13 A"},{"name":"","range":"20 A 至 100 A","cmc":"0,65 % + 0,17 A"},{"name":"","range":"100 A 至 500 A","cmc":"0,53 % + 0,52 A"}],"parameters_cs":[{"name":"","range":"0 A až 20 A","cmc":"0,56 % + 0,13 A"},{"name":"","range":"20 A až 100 A","cmc":"0,65 % + 0,17 A"},{"name":"","range":"100 A až 500 A","cmc":"0,53 % + 0,52 A"}],"technique":"Symulacja prądu wzorcowego kalibratorem i cewką prądową","technique_en":"Reference current simulation with a calibrator and current coil","technique_zh":"用校准器和电流线圈模拟标准电流","technique_cs":"Simulace etalonového proudu kalibrátorem a proudovou cívkou","techniques":["Symulacja prądu wzorcowego kalibratorem i cewką prądową"],"techniques_en":["Reference current simulation with a calibrator and current coil"],"techniques_zh":["用校准器和电流线圈模拟标准电流"],"techniques_cs":["Simulace etalonového proudu kalibrátorem a proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 A do 20 A CMC 0,56 % + 0,13 A\nod 20 A do 100 A CMC 0,65 % + 0,17 A\nod 100 A do 500 A CMC 0,53 % + 0,52 A\nSymulacja prądu wzorcowego kalibratorem i cewką prądową","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Mierniki prądu stałego Wzorcowanie – wielkości elektryczne Symulacja prądu wzorcowego kalibratorem i cewką prądową od 0 A do 20 A CMC 0,56 % + 0,13 A od 20 A do 100 A CMC 0,65 % + 0,17 A od 100 A do 500 A CMC 0,53 % + 0,52 A Stejnosměrný proud / Měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Simulace etalonového proudu kalibrátorem a proudovou cívkou 0 A až 20 A CMC 0,56 % + 0,13 A 20 A až 100 A CMC 0,65 % + 0,17 A 100 A až 500 A CMC 0,53 % + 0,52 A Kp 04-001, Kp 04-003 Prad staly / Mierniki pradu stalego Wzorcowanie – wielkosci elektryczne Symulacja pradu wzorcowego kalibratorem i cewka pradowa od 0 A do 20 A CMC 0,56 % + 0,13 A od 20 A do 100 A CMC 0,65 % + 0,17 A od 100 A do 500 A CMC 0,53 % + 0,52 A Stejnosmerny proud / Meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Simulace etalonoveho proudu kalibratorem a proudovou civkou 0 A az 20 A CMC 0,56 % + 0,13 A 20 A az 100 A CMC 0,65 % + 0,17 A 100 A az 500 A CMC 0,53 % + 0,52 A Kp 04-001, Kp 04-003","search_en":"Direct current / Direct current meters Calibration – electrical quantities Reference current simulation with a calibrator and current coil 0 A to 20 A CMC 0,56 % + 0,13 A 20 A to 100 A CMC 0,65 % + 0,17 A 100 A to 500 A CMC 0,53 % + 0,52 A Kp 04-001, Kp 04-003","search_zh":"直流电流 / 直流电流表 校准 – 电学量 用校准器和电流线圈模拟标准电流 0 A 至 20 A CMC 0,56 % + 0,13 A 20 A 至 100 A CMC 0,65 % + 0,17 A 100 A 至 500 A CMC 0,53 % + 0,52 A Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"16f50153b82f3fb9645d6b09","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / Źródła napięcia przemiennego","test_object_en":"Alternating-current voltage / AC voltage sources","test_object_zh":"交流电压 / 交流电压源","test_object_cs":"Střídavé napětí / Zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 20 kHz","range":"od 0,1 mV do 100 mV","cmc":"0,06 % + 51 µV"},{"name":"10 Hz do 20 kHz","range":"od 0,1 V do 1 V","cmc":"0,06 % + 0,36 mV"},{"name":"10 Hz do 20 kHz","range":"od 1 V do 10 V","cmc":"0,06 % + 3,6 mV"},{"name":"10 Hz do 20 kHz","range":"od 10 V do 100 V","cmc":"0,06 % + 37 mV"},{"name":"10 Hz do 20 kHz","range":"od 100 V do 1000 V","cmc":"0,06 % + 0,29 V"}],"parameters_en":[{"name":"10 Hz to 20 kHz","range":"0,1 mV to 100 mV","cmc":"0,06 % + 51 µV"},{"name":"10 Hz to 20 kHz","range":"0,1 V to 1 V","cmc":"0,06 % + 0,36 mV"},{"name":"10 Hz to 20 kHz","range":"1 V to 10 V","cmc":"0,06 % + 3,6 mV"},{"name":"10 Hz to 20 kHz","range":"10 V to 100 V","cmc":"0,06 % + 37 mV"},{"name":"10 Hz to 20 kHz","range":"100 V to 1000 V","cmc":"0,06 % + 0,29 V"}],"parameters_zh":[{"name":"10 Hz 至 20 kHz","range":"0,1 mV 至 100 mV","cmc":"0,06 % + 51 µV"},{"name":"10 Hz 至 20 kHz","range":"0,1 V 至 1 V","cmc":"0,06 % + 0,36 mV"},{"name":"10 Hz 至 20 kHz","range":"1 V 至 10 V","cmc":"0,06 % + 3,6 mV"},{"name":"10 Hz 至 20 kHz","range":"10 V 至 100 V","cmc":"0,06 % + 37 mV"},{"name":"10 Hz 至 20 kHz","range":"100 V 至 1000 V","cmc":"0,06 % + 0,29 V"}],"parameters_cs":[{"name":"10 Hz až 20 kHz","range":"0,1 mV až 100 mV","cmc":"0,06 % + 51 µV"},{"name":"10 Hz až 20 kHz","range":"0,1 V až 1 V","cmc":"0,06 % + 0,36 mV"},{"name":"10 Hz až 20 kHz","range":"1 V až 10 V","cmc":"0,06 % + 3,6 mV"},{"name":"10 Hz až 20 kHz","range":"10 V až 100 V","cmc":"0,06 % + 37 mV"},{"name":"10 Hz až 20 kHz","range":"100 V až 1000 V","cmc":"0,06 % + 0,29 V"}],"technique":"Bezpośredni pomiar multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Bezpośredni pomiar multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 20 kHz od 0,1 mV do 100 mV CMC 0,06 % + 51 µV\n10 Hz do 20 kHz od 0,1 V do 1 V CMC 0,06 % + 0,36 mV\n10 Hz do 20 kHz od 1 V do 10 V CMC 0,06 % + 3,6 mV\n10 Hz do 20 kHz od 10 V do 100 V CMC 0,06 % + 37 mV\n10 Hz do 20 kHz od 100 V do 1000 V CMC 0,06 % + 0,29 V\nBezpośredni pomiar multimetrem wzorcowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / Źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Bezpośredni pomiar multimetrem wzorcowym 10 Hz do 20 kHz od 0,1 mV do 100 mV CMC 0,06 % + 51 µV 10 Hz do 20 kHz od 0,1 V do 1 V CMC 0,06 % + 0,36 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,06 % + 3,6 mV 10 Hz do 20 kHz od 10 V do 100 V CMC 0,06 % + 37 mV 10 Hz do 20 kHz od 100 V do 1000 V CMC 0,06 % + 0,29 V Střídavé napětí / Zdroje střídavého napětí Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 10 Hz až 20 kHz 0,1 mV až 100 mV CMC 0,06 % + 51 µV 10 Hz až 20 kHz 0,1 V až 1 V CMC 0,06 % + 0,36 mV 10 Hz až 20 kHz 1 V až 10 V CMC 0,06 % + 3,6 mV 10 Hz až 20 kHz 10 V až 100 V CMC 0,06 % + 37 mV 10 Hz až 20 kHz 100 V až 1000 V CMC 0,06 % + 0,29 V Kp 04-001, Kp 04-003 Napiecie przemienne / Zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Bezposredni pomiar multimetrem wzorcowym 10 Hz do 20 kHz od 0,1 mV do 100 mV CMC 0,06 % + 51 µV 10 Hz do 20 kHz od 0,1 V do 1 V CMC 0,06 % + 0,36 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,06 % + 3,6 mV 10 Hz do 20 kHz od 10 V do 100 V CMC 0,06 % + 37 mV 10 Hz do 20 kHz od 100 V do 1000 V CMC 0,06 % + 0,29 V Stridave napeti / Zdroje stridaveho napeti Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 10 Hz az 20 kHz 0,1 mV az 100 mV CMC 0,06 % + 51 µV 10 Hz az 20 kHz 0,1 V az 1 V CMC 0,06 % + 0,36 mV 10 Hz az 20 kHz 1 V az 10 V CMC 0,06 % + 3,6 mV 10 Hz az 20 kHz 10 V az 100 V CMC 0,06 % + 37 mV 10 Hz az 20 kHz 100 V az 1000 V CMC 0,06 % + 0,29 V Kp 04-001, Kp 04-003","search_en":"Alternating-current voltage / AC voltage sources Calibration – electrical quantities Direct measurement by a reference multimeter 10 Hz to 20 kHz 0,1 mV to 100 mV CMC 0,06 % + 51 µV 10 Hz to 20 kHz 0,1 V to 1 V CMC 0,06 % + 0,36 mV 10 Hz to 20 kHz 1 V to 10 V CMC 0,06 % + 3,6 mV 10 Hz to 20 kHz 10 V to 100 V CMC 0,06 % + 37 mV 10 Hz to 20 kHz 100 V to 1000 V CMC 0,06 % + 0,29 V Kp 04-001, Kp 04-003","search_zh":"交流电压 / 交流电压源 校准 – 电学量 用标准万用表直接测量 10 Hz 至 20 kHz 0,1 mV 至 100 mV CMC 0,06 % + 51 µV 10 Hz 至 20 kHz 0,1 V 至 1 V CMC 0,06 % + 0,36 mV 10 Hz 至 20 kHz 1 V 至 10 V CMC 0,06 % + 3,6 mV 10 Hz 至 20 kHz 10 V 至 100 V CMC 0,06 % + 37 mV 10 Hz 至 20 kHz 100 V 至 1000 V CMC 0,06 % + 0,29 V Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ea05a71c30a7a9c9a2199cf","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / Źródła napięcia przemiennego","test_object_en":"Alternating-current voltage / AC voltage sources","test_object_zh":"交流电压 / 交流电压源","test_object_cs":"Střídavé napětí / Zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz do 60 Hz","range":"od 1 kV do 3 kV","cmc":"0,5 % + 0,039 kV"},{"name":"50 Hz do 60 Hz","range":"od 3 kV do 10 kV","cmc":"0,5 % + 0,11 kV"}],"parameters_en":[{"name":"50 Hz to 60 Hz","range":"1 kV to 3 kV","cmc":"0,5 % + 0,039 kV"},{"name":"50 Hz to 60 Hz","range":"3 kV to 10 kV","cmc":"0,5 % + 0,11 kV"}],"parameters_zh":[{"name":"50 Hz 至 60 Hz","range":"1 kV 至 3 kV","cmc":"0,5 % + 0,039 kV"},{"name":"50 Hz 至 60 Hz","range":"3 kV 至 10 kV","cmc":"0,5 % + 0,11 kV"}],"parameters_cs":[{"name":"50 Hz až 60 Hz","range":"1 kV až 3 kV","cmc":"0,5 % + 0,039 kV"},{"name":"50 Hz až 60 Hz","range":"3 kV až 10 kV","cmc":"0,5 % + 0,11 kV"}],"technique":"Pośredni pomiar kalibratorem wzorcowym z adapterem Hipot","technique_en":"Indirect measurement with a reference calibrator with a Hipot adapter","technique_zh":"用带 Hipot 适配器的标准校准器间接测量","technique_cs":"Nepřímé měření etalonovým kalibrátorem s Hipot adaptérem","techniques":["Pośredni pomiar kalibratorem wzorcowym z adapterem Hipot"],"techniques_en":["Indirect measurement with a reference calibrator with a Hipot adapter"],"techniques_zh":["用带 Hipot 适配器的标准校准器间接测量"],"techniques_cs":["Nepřímé měření etalonovým kalibrátorem s Hipot adaptérem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz do 60 Hz od 1 kV do 3 kV CMC 0,5 % + 0,039 kV\n50 Hz do 60 Hz od 3 kV do 10 kV CMC 0,5 % + 0,11 kV\nPośredni pomiar kalibratorem wzorcowym z adapterem Hipot","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / Źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Pośredni pomiar kalibratorem wzorcowym z adapterem Hipot 50 Hz do 60 Hz od 1 kV do 3 kV CMC 0,5 % + 0,039 kV 50 Hz do 60 Hz od 3 kV do 10 kV CMC 0,5 % + 0,11 kV Střídavé napětí / Zdroje střídavého napětí Kalibrace – elektrické veličiny Nepřímé měření etalonovým kalibrátorem s Hipot adaptérem 50 Hz až 60 Hz 1 kV až 3 kV CMC 0,5 % + 0,039 kV 50 Hz až 60 Hz 3 kV až 10 kV CMC 0,5 % + 0,11 kV Kp 04-001, Kp 04-003 Napiecie przemienne / Zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Posredni pomiar kalibratorem wzorcowym z adapterem Hipot 50 Hz do 60 Hz od 1 kV do 3 kV CMC 0,5 % + 0,039 kV 50 Hz do 60 Hz od 3 kV do 10 kV CMC 0,5 % + 0,11 kV Stridave napeti / Zdroje stridaveho napeti Kalibrace – elektricke veliciny Neprime mereni etalonovym kalibratorem s Hipot adapterem 50 Hz az 60 Hz 1 kV az 3 kV CMC 0,5 % + 0,039 kV 50 Hz az 60 Hz 3 kV az 10 kV CMC 0,5 % + 0,11 kV Kp 04-001, Kp 04-003","search_en":"Alternating-current voltage / AC voltage sources Calibration – electrical quantities Indirect measurement with a reference calibrator with a Hipot adapter 50 Hz to 60 Hz 1 kV to 3 kV CMC 0,5 % + 0,039 kV 50 Hz to 60 Hz 3 kV to 10 kV CMC 0,5 % + 0,11 kV Kp 04-001, Kp 04-003","search_zh":"交流电压 / 交流电压源 校准 – 电学量 用带 Hipot 适配器的标准校准器间接测量 50 Hz 至 60 Hz 1 kV 至 3 kV CMC 0,5 % + 0,039 kV 50 Hz 至 60 Hz 3 kV 至 10 kV CMC 0,5 % + 0,11 kV Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"af6cb190210cda10ebad04d9","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / Mierniki napięcia przemiennego","test_object_en":"Alternating-current voltage / AC voltage meters","test_object_zh":"交流电压 / 交流电压表","test_object_cs":"Střídavé napětí / Měřidla střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 2 kHz","range":"od 0,1 mV do 100 mV","cmc":"0,08 % + 43 µV"},{"name":"10 Hz do 2 kHz","range":"od 0,1 V do 1 V","cmc":"0,08 % + 0,39 mV"},{"name":"10 Hz do 2 kHz","range":"od 1 V do 10 V","cmc":"0,08 % + 4,0 mV"},{"name":"40 Hz do 1 kHz","range":"od 10 V do 100 V","cmc":"0,08 % + 43 mV"},{"name":"40 Hz do 1 kHz","range":"od 100 V do 1000 V","cmc":"0,08 % + 0,60 mV"}],"parameters_en":[{"name":"10 Hz to 2 kHz","range":"0,1 mV to 100 mV","cmc":"0,08 % + 43 µV"},{"name":"10 Hz to 2 kHz","range":"0,1 V to 1 V","cmc":"0,08 % + 0,39 mV"},{"name":"10 Hz to 2 kHz","range":"1 V to 10 V","cmc":"0,08 % + 4,0 mV"},{"name":"40 Hz to 1 kHz","range":"10 V to 100 V","cmc":"0,08 % + 43 mV"},{"name":"40 Hz to 1 kHz","range":"100 V to 1000 V","cmc":"0,08 % + 0,60 mV"}],"parameters_zh":[{"name":"10 Hz 至 2 kHz","range":"0,1 mV 至 100 mV","cmc":"0,08 % + 43 µV"},{"name":"10 Hz 至 2 kHz","range":"0,1 V 至 1 V","cmc":"0,08 % + 0,39 mV"},{"name":"10 Hz 至 2 kHz","range":"1 V 至 10 V","cmc":"0,08 % + 4,0 mV"},{"name":"40 Hz 至 1 kHz","range":"10 V 至 100 V","cmc":"0,08 % + 43 mV"},{"name":"40 Hz 至 1 kHz","range":"100 V 至 1000 V","cmc":"0,08 % + 0,60 mV"}],"parameters_cs":[{"name":"10 Hz až 2 kHz","range":"0,1 mV až 100 mV","cmc":"0,08 % + 43 µV"},{"name":"10 Hz až 2 kHz","range":"0,1 V až 1 V","cmc":"0,08 % + 0,39 mV"},{"name":"10 Hz až 2 kHz","range":"1 V až 10 V","cmc":"0,08 % + 4,0 mV"},{"name":"40 Hz až 1 kHz","range":"10 V až 100 V","cmc":"0,08 % + 43 mV"},{"name":"40 Hz až 1 kHz","range":"100 V až 1000 V","cmc":"0,08 % + 0,60 mV"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a reference calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a reference calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 2 kHz od 0,1 mV do 100 mV CMC 0,08 % + 43 µV\n10 Hz do 2 kHz od 0,1 V do 1 V CMC 0,08 % + 0,39 mV\n10 Hz do 2 kHz od 1 V do 10 V CMC 0,08 % + 4,0 mV\n40 Hz do 1 kHz od 10 V do 100 V CMC 0,08 % + 43 mV\n40 Hz do 1 kHz od 100 V do 1000 V CMC 0,08 % + 0,60 mV\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / Mierniki napięcia przemiennego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym 10 Hz do 2 kHz od 0,1 mV do 100 mV CMC 0,08 % + 43 µV 10 Hz do 2 kHz od 0,1 V do 1 V CMC 0,08 % + 0,39 mV 10 Hz do 2 kHz od 1 V do 10 V CMC 0,08 % + 4,0 mV 40 Hz do 1 kHz od 10 V do 100 V CMC 0,08 % + 43 mV 40 Hz do 1 kHz od 100 V do 1000 V CMC 0,08 % + 0,60 mV Střídavé napětí / Měřidla střídavého napětí Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 10 Hz až 2 kHz 0,1 mV až 100 mV CMC 0,08 % + 43 µV 10 Hz až 2 kHz 0,1 V až 1 V CMC 0,08 % + 0,39 mV 10 Hz až 2 kHz 1 V až 10 V CMC 0,08 % + 4,0 mV 40 Hz až 1 kHz 10 V až 100 V CMC 0,08 % + 43 mV 40 Hz až 1 kHz 100 V až 1000 V CMC 0,08 % + 0,60 mV Kp 04-001, Kp 04-003 Napiecie przemienne / Mierniki napiecia przemiennego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym 10 Hz do 2 kHz od 0,1 mV do 100 mV CMC 0,08 % + 43 µV 10 Hz do 2 kHz od 0,1 V do 1 V CMC 0,08 % + 0,39 mV 10 Hz do 2 kHz od 1 V do 10 V CMC 0,08 % + 4,0 mV 40 Hz do 1 kHz od 10 V do 100 V CMC 0,08 % + 43 mV 40 Hz do 1 kHz od 100 V do 1000 V CMC 0,08 % + 0,60 mV Stridave napeti / Meridla stridaveho napeti Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 10 Hz az 2 kHz 0,1 mV az 100 mV CMC 0,08 % + 43 µV 10 Hz az 2 kHz 0,1 V az 1 V CMC 0,08 % + 0,39 mV 10 Hz az 2 kHz 1 V az 10 V CMC 0,08 % + 4,0 mV 40 Hz az 1 kHz 10 V az 100 V CMC 0,08 % + 43 mV 40 Hz az 1 kHz 100 V az 1000 V CMC 0,08 % + 0,60 mV Kp 04-001, Kp 04-003","search_en":"Alternating-current voltage / AC voltage meters Calibration – electrical quantities Direct generation with a reference calibrator 10 Hz to 2 kHz 0,1 mV to 100 mV CMC 0,08 % + 43 µV 10 Hz to 2 kHz 0,1 V to 1 V CMC 0,08 % + 0,39 mV 10 Hz to 2 kHz 1 V to 10 V CMC 0,08 % + 4,0 mV 40 Hz to 1 kHz 10 V to 100 V CMC 0,08 % + 43 mV 40 Hz to 1 kHz 100 V to 1000 V CMC 0,08 % + 0,60 mV Kp 04-001, Kp 04-003","search_zh":"交流电压 / 交流电压表 校准 – 电学量 用标准校准器直接产生 10 Hz 至 2 kHz 0,1 mV 至 100 mV CMC 0,08 % + 43 µV 10 Hz 至 2 kHz 0,1 V 至 1 V CMC 0,08 % + 0,39 mV 10 Hz 至 2 kHz 1 V 至 10 V CMC 0,08 % + 4,0 mV 40 Hz 至 1 kHz 10 V 至 100 V CMC 0,08 % + 43 mV 40 Hz 至 1 kHz 100 V 至 1000 V CMC 0,08 % + 0,60 mV Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d677b209dbfe783abd27f909","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / Źródła prądu przemiennego","test_object_en":"Alternating current / Alternating current sources","test_object_zh":"交流电流 / 交流电流源","test_object_cs":"Střídavý proud / Zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 2 kHz","range":"od 0,1 µA do 100 µA","cmc":"0,15 % + 80 nA"},{"name":"10 Hz do 2 kHz","range":"od 0,1 mA do 1 mA","cmc":"0,10 % + 0,54 µA"},{"name":"10 Hz do 2 kHz","range":"od 1 mA do 10 mA","cmc":"0,15 % + 7,5 µA"},{"name":"10 Hz do 2 kHz","range":"od 10 mA do 100 mA","cmc":"0,10 % + 56 µA"},{"name":"10 Hz do 1 kHz","range":"od 100 mA do 400 mA","cmc":"0,10 % + 0,51 mA"},{"name":"10 Hz do 2 kHz","range":"od 0,4 A do 1 A","cmc":"0,10 % + 0,8 mA"},{"name":"10 Hz do 2 kHz","range":"od 1 A do 3 A","cmc":"0,15 % + 2,4 mA"},{"name":"10 Hz do 2 kHz","range":"od 3 A do 10 A","cmc":"0,15 % + 16 mA"}],"parameters_en":[{"name":"10 Hz to 2 kHz","range":"0,1 µA to 100 µA","cmc":"0,15 % + 80 nA"},{"name":"10 Hz to 2 kHz","range":"0,1 mA to 1 mA","cmc":"0,10 % + 0,54 µA"},{"name":"10 Hz to 2 kHz","range":"1 mA to 10 mA","cmc":"0,15 % + 7,5 µA"},{"name":"10 Hz to 2 kHz","range":"10 mA to 100 mA","cmc":"0,10 % + 56 µA"},{"name":"10 Hz to 1 kHz","range":"100 mA to 400 mA","cmc":"0,10 % + 0,51 mA"},{"name":"10 Hz to 2 kHz","range":"0,4 A to 1 A","cmc":"0,10 % + 0,8 mA"},{"name":"10 Hz to 2 kHz","range":"1 A to 3 A","cmc":"0,15 % + 2,4 mA"},{"name":"10 Hz to 2 kHz","range":"3 A to 10 A","cmc":"0,15 % + 16 mA"}],"parameters_zh":[{"name":"10 Hz 至 2 kHz","range":"0,1 µA 至 100 µA","cmc":"0,15 % + 80 nA"},{"name":"10 Hz 至 2 kHz","range":"0,1 mA 至 1 mA","cmc":"0,10 % + 0,54 µA"},{"name":"10 Hz 至 2 kHz","range":"1 mA 至 10 mA","cmc":"0,15 % + 7,5 µA"},{"name":"10 Hz 至 2 kHz","range":"10 mA 至 100 mA","cmc":"0,10 % + 56 µA"},{"name":"10 Hz 至 1 kHz","range":"100 mA 至 400 mA","cmc":"0,10 % + 0,51 mA"},{"name":"10 Hz 至 2 kHz","range":"0,4 A 至 1 A","cmc":"0,10 % + 0,8 mA"},{"name":"10 Hz 至 2 kHz","range":"1 A 至 3 A","cmc":"0,15 % + 2,4 mA"},{"name":"10 Hz 至 2 kHz","range":"3 A 至 10 A","cmc":"0,15 % + 16 mA"}],"parameters_cs":[{"name":"10 Hz až 2 kHz","range":"0,1 µA až 100 µA","cmc":"0,15 % + 80 nA"},{"name":"10 Hz až 2 kHz","range":"0,1 mA až 1 mA","cmc":"0,10 % + 0,54 µA"},{"name":"10 Hz až 2 kHz","range":"1 mA až 10 mA","cmc":"0,15 % + 7,5 µA"},{"name":"10 Hz až 2 kHz","range":"10 mA až 100 mA","cmc":"0,10 % + 56 µA"},{"name":"10 Hz až 1 kHz","range":"100 mA až 400 mA","cmc":"0,10 % + 0,51 mA"},{"name":"10 Hz až 2 kHz","range":"0,4 A až 1 A","cmc":"0,10 % + 0,8 mA"},{"name":"10 Hz až 2 kHz","range":"1 A až 3 A","cmc":"0,15 % + 2,4 mA"},{"name":"10 Hz až 2 kHz","range":"3 A až 10 A","cmc":"0,15 % + 16 mA"}],"technique":"Bezpośredni pomiar multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Bezpośredni pomiar multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 2 kHz od 0,1 µA do 100 µA CMC 0,15 % + 80 nA\n10 Hz do 2 kHz od 0,1 mA do 1 mA CMC 0,10 % + 0,54 µA\n10 Hz do 2 kHz od 1 mA do 10 mA CMC 0,15 % + 7,5 µA\n10 Hz do 2 kHz od 10 mA do 100 mA CMC 0,10 % + 56 µA\n10 Hz do 1 kHz od 100 mA do 400 mA CMC 0,10 % + 0,51 mA\n10 Hz do 2 kHz od 0,4 A do 1 A CMC 0,10 % + 0,8 mA\n10 Hz do 2 kHz od 1 A do 3 A CMC 0,15 % + 2,4 mA\n10 Hz do 2 kHz od 3 A do 10 A CMC 0,15 % + 16 mA\nBezpośredni pomiar multimetrem wzorcowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / Źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Bezpośredni pomiar multimetrem wzorcowym 10 Hz do 2 kHz od 0,1 µA do 100 µA CMC 0,15 % + 80 nA 10 Hz do 2 kHz od 0,1 mA do 1 mA CMC 0,10 % + 0,54 µA 10 Hz do 2 kHz od 1 mA do 10 mA CMC 0,15 % + 7,5 µA 10 Hz do 2 kHz od 10 mA do 100 mA CMC 0,10 % + 56 µA 10 Hz do 1 kHz od 100 mA do 400 mA CMC 0,10 % + 0,51 mA 10 Hz do 2 kHz od 0,4 A do 1 A CMC 0,10 % + 0,8 mA 10 Hz do 2 kHz od 1 A do 3 A CMC 0,15 % + 2,4 mA 10 Hz do 2 kHz od 3 A do 10 A CMC 0,15 % + 16 mA Střídavý proud / Zdroje střídavého proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 10 Hz až 2 kHz 0,1 µA až 100 µA CMC 0,15 % + 80 nA 10 Hz až 2 kHz 0,1 mA až 1 mA CMC 0,10 % + 0,54 µA 10 Hz až 2 kHz 1 mA až 10 mA CMC 0,15 % + 7,5 µA 10 Hz až 2 kHz 10 mA až 100 mA CMC 0,10 % + 56 µA 10 Hz až 1 kHz 100 mA až 400 mA CMC 0,10 % + 0,51 mA 10 Hz až 2 kHz 0,4 A až 1 A CMC 0,10 % + 0,8 mA 10 Hz až 2 kHz 1 A až 3 A CMC 0,15 % + 2,4 mA 10 Hz až 2 kHz 3 A až 10 A CMC 0,15 % + 16 mA Kp 04-001, Kp 04-003 Prad przemienny / Zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Bezposredni pomiar multimetrem wzorcowym 10 Hz do 2 kHz od 0,1 µA do 100 µA CMC 0,15 % + 80 nA 10 Hz do 2 kHz od 0,1 mA do 1 mA CMC 0,10 % + 0,54 µA 10 Hz do 2 kHz od 1 mA do 10 mA CMC 0,15 % + 7,5 µA 10 Hz do 2 kHz od 10 mA do 100 mA CMC 0,10 % + 56 µA 10 Hz do 1 kHz od 100 mA do 400 mA CMC 0,10 % + 0,51 mA 10 Hz do 2 kHz od 0,4 A do 1 A CMC 0,10 % + 0,8 mA 10 Hz do 2 kHz od 1 A do 3 A CMC 0,15 % + 2,4 mA 10 Hz do 2 kHz od 3 A do 10 A CMC 0,15 % + 16 mA Stridavy proud / Zdroje stridaveho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 10 Hz az 2 kHz 0,1 µA az 100 µA CMC 0,15 % + 80 nA 10 Hz az 2 kHz 0,1 mA az 1 mA CMC 0,10 % + 0,54 µA 10 Hz az 2 kHz 1 mA az 10 mA CMC 0,15 % + 7,5 µA 10 Hz az 2 kHz 10 mA az 100 mA CMC 0,10 % + 56 µA 10 Hz az 1 kHz 100 mA az 400 mA CMC 0,10 % + 0,51 mA 10 Hz az 2 kHz 0,4 A az 1 A CMC 0,10 % + 0,8 mA 10 Hz az 2 kHz 1 A az 3 A CMC 0,15 % + 2,4 mA 10 Hz az 2 kHz 3 A az 10 A CMC 0,15 % + 16 mA Kp 04-001, Kp 04-003","search_en":"Alternating current / Alternating current sources Calibration – electrical quantities Direct measurement by a reference multimeter 10 Hz to 2 kHz 0,1 µA to 100 µA CMC 0,15 % + 80 nA 10 Hz to 2 kHz 0,1 mA to 1 mA CMC 0,10 % + 0,54 µA 10 Hz to 2 kHz 1 mA to 10 mA CMC 0,15 % + 7,5 µA 10 Hz to 2 kHz 10 mA to 100 mA CMC 0,10 % + 56 µA 10 Hz to 1 kHz 100 mA to 400 mA CMC 0,10 % + 0,51 mA 10 Hz to 2 kHz 0,4 A to 1 A CMC 0,10 % + 0,8 mA 10 Hz to 2 kHz 1 A to 3 A CMC 0,15 % + 2,4 mA 10 Hz to 2 kHz 3 A to 10 A CMC 0,15 % + 16 mA Kp 04-001, Kp 04-003","search_zh":"交流电流 / 交流电流源 校准 – 电学量 用标准万用表直接测量 10 Hz 至 2 kHz 0,1 µA 至 100 µA CMC 0,15 % + 80 nA 10 Hz 至 2 kHz 0,1 mA 至 1 mA CMC 0,10 % + 0,54 µA 10 Hz 至 2 kHz 1 mA 至 10 mA CMC 0,15 % + 7,5 µA 10 Hz 至 2 kHz 10 mA 至 100 mA CMC 0,10 % + 56 µA 10 Hz 至 1 kHz 100 mA 至 400 mA CMC 0,10 % + 0,51 mA 10 Hz 至 2 kHz 0,4 A 至 1 A CMC 0,10 % + 0,8 mA 10 Hz 至 2 kHz 1 A 至 3 A CMC 0,15 % + 2,4 mA 10 Hz 至 2 kHz 3 A 至 10 A CMC 0,15 % + 16 mA Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29bf019caf25b4f71f5bdbc1","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / Źródła prądu przemiennego","test_object_en":"Alternating current / Alternating current sources","test_object_zh":"交流电流 / 交流电流源","test_object_cs":"Střídavý proud / Zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"30 Hz do 60 Hz","range":"od 0 A do 40 A","cmc":"2,0 % + 0,46 A"},{"name":"30 Hz do 60 Hz","range":"od 40 A do 400 A","cmc":"2,8 % + 2,9 A"}],"parameters_en":[{"name":"30 Hz to 60 Hz","range":"0 A to 40 A","cmc":"2,0 % + 0,46 A"},{"name":"30 Hz to 60 Hz","range":"40 A to 400 A","cmc":"2,8 % + 2,9 A"}],"parameters_zh":[{"name":"30 Hz 至 60 Hz","range":"0 A 至 40 A","cmc":"2,0 % + 0,46 A"},{"name":"30 Hz 至 60 Hz","range":"40 A 至 400 A","cmc":"2,8 % + 2,9 A"}],"parameters_cs":[{"name":"30 Hz až 60 Hz","range":"0 A až 40 A","cmc":"2,0 % + 0,46 A"},{"name":"30 Hz až 60 Hz","range":"40 A až 400 A","cmc":"2,8 % + 2,9 A"}],"technique":"Bezpośredni pomiar wzorcowym multimetrem cęgowym","technique_en":"Direct measurement by a reference clamp multimeter","technique_zh":"用标准钳形万用表直接测量","technique_cs":"Přímé měření etalonovým klešťovým multimetrem","techniques":["Bezpośredni pomiar wzorcowym multimetrem cęgowym"],"techniques_en":["Direct measurement by a reference clamp multimeter"],"techniques_zh":["用标准钳形万用表直接测量"],"techniques_cs":["Přímé měření etalonovým klešťovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n30 Hz do 60 Hz od 0 A do 40 A CMC 2,0 % + 0,46 A\n30 Hz do 60 Hz od 40 A do 400 A CMC 2,8 % + 2,9 A\nBezpośredni pomiar wzorcowym multimetrem cęgowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / Źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Bezpośredni pomiar wzorcowym multimetrem cęgowym 30 Hz do 60 Hz od 0 A do 40 A CMC 2,0 % + 0,46 A 30 Hz do 60 Hz od 40 A do 400 A CMC 2,8 % + 2,9 A Střídavý proud / Zdroje střídavého proudu Kalibrace – elektrické veličiny Přímé měření etalonovým klešťovým multimetrem 30 Hz až 60 Hz 0 A až 40 A CMC 2,0 % + 0,46 A 30 Hz až 60 Hz 40 A až 400 A CMC 2,8 % + 2,9 A Kp 04-001, Kp 04-003 Prad przemienny / Zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Bezposredni pomiar wzorcowym multimetrem cegowym 30 Hz do 60 Hz od 0 A do 40 A CMC 2,0 % + 0,46 A 30 Hz do 60 Hz od 40 A do 400 A CMC 2,8 % + 2,9 A Stridavy proud / Zdroje stridaveho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym klestovym multimetrem 30 Hz az 60 Hz 0 A az 40 A CMC 2,0 % + 0,46 A 30 Hz az 60 Hz 40 A az 400 A CMC 2,8 % + 2,9 A Kp 04-001, Kp 04-003","search_en":"Alternating current / Alternating current sources Calibration – electrical quantities Direct measurement by a reference clamp multimeter 30 Hz to 60 Hz 0 A to 40 A CMC 2,0 % + 0,46 A 30 Hz to 60 Hz 40 A to 400 A CMC 2,8 % + 2,9 A Kp 04-001, Kp 04-003","search_zh":"交流电流 / 交流电流源 校准 – 电学量 用标准钳形万用表直接测量 30 Hz 至 60 Hz 0 A 至 40 A CMC 2,0 % + 0,46 A 30 Hz 至 60 Hz 40 A 至 400 A CMC 2,8 % + 2,9 A Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3aac4c15e4730d0b6115cc54","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / Mierniki prądu przemiennego","test_object_en":"Alternating current / Alternating current meters","test_object_zh":"交流电流 / 交流电流表","test_object_cs":"Střídavý proud / Měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 2 kHz","range":"od 0,1 µA do 100 µA","cmc":"0,1 % + 0,47 µA"},{"name":"10 Hz do 2 kHz","range":"od 0,1 mA do 1 mA","cmc":"0,1 % + 0,96 µA"},{"name":"10 Hz do 2 kHz","range":"od 1 mA do 10 mA","cmc":"0,1 % + 9,5 µA"},{"name":"10 Hz do 2 kHz","range":"od 10 mA do 100 mA","cmc":"0,1 % + 96 µA"},{"name":"10 Hz do 2 kHz","range":"od 0,1 A do 1 A","cmc":"0,1 % + 0,95 mA"},{"name":"10 Hz do 2 kHz","range":"od 1 A do 10 A","cmc":"0,1 % + 20 mA"}],"parameters_en":[{"name":"10 Hz to 2 kHz","range":"0,1 µA to 100 µA","cmc":"0,1 % + 0,47 µA"},{"name":"10 Hz to 2 kHz","range":"0,1 mA to 1 mA","cmc":"0,1 % + 0,96 µA"},{"name":"10 Hz to 2 kHz","range":"1 mA to 10 mA","cmc":"0,1 % + 9,5 µA"},{"name":"10 Hz to 2 kHz","range":"10 mA to 100 mA","cmc":"0,1 % + 96 µA"},{"name":"10 Hz to 2 kHz","range":"0,1 A to 1 A","cmc":"0,1 % + 0,95 mA"},{"name":"10 Hz to 2 kHz","range":"1 A to 10 A","cmc":"0,1 % + 20 mA"}],"parameters_zh":[{"name":"10 Hz 至 2 kHz","range":"0,1 µA 至 100 µA","cmc":"0,1 % + 0,47 µA"},{"name":"10 Hz 至 2 kHz","range":"0,1 mA 至 1 mA","cmc":"0,1 % + 0,96 µA"},{"name":"10 Hz 至 2 kHz","range":"1 mA 至 10 mA","cmc":"0,1 % + 9,5 µA"},{"name":"10 Hz 至 2 kHz","range":"10 mA 至 100 mA","cmc":"0,1 % + 96 µA"},{"name":"10 Hz 至 2 kHz","range":"0,1 A 至 1 A","cmc":"0,1 % + 0,95 mA"},{"name":"10 Hz 至 2 kHz","range":"1 A 至 10 A","cmc":"0,1 % + 20 mA"}],"parameters_cs":[{"name":"10 Hz až 2 kHz","range":"0,1 µA až 100 µA","cmc":"0,1 % + 0,47 µA"},{"name":"10 Hz až 2 kHz","range":"0,1 mA až 1 mA","cmc":"0,1 % + 0,96 µA"},{"name":"10 Hz až 2 kHz","range":"1 mA až 10 mA","cmc":"0,1 % + 9,5 µA"},{"name":"10 Hz až 2 kHz","range":"10 mA až 100 mA","cmc":"0,1 % + 96 µA"},{"name":"10 Hz až 2 kHz","range":"0,1 A až 1 A","cmc":"0,1 % + 0,95 mA"},{"name":"10 Hz až 2 kHz","range":"1 A až 10 A","cmc":"0,1 % + 20 mA"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a reference calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a reference calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 2 kHz od 0,1 µA do 100 µA CMC 0,1 % + 0,47 µA\n10 Hz do 2 kHz od 0,1 mA do 1 mA CMC 0,1 % + 0,96 µA\n10 Hz do 2 kHz od 1 mA do 10 mA CMC 0,1 % + 9,5 µA\n10 Hz do 2 kHz od 10 mA do 100 mA CMC 0,1 % + 96 µA\n10 Hz do 2 kHz od 0,1 A do 1 A CMC 0,1 % + 0,95 mA\n10 Hz do 2 kHz od 1 A do 10 A CMC 0,1 % + 20 mA\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / Mierniki prądu przemiennego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym 10 Hz do 2 kHz od 0,1 µA do 100 µA CMC 0,1 % + 0,47 µA 10 Hz do 2 kHz od 0,1 mA do 1 mA CMC 0,1 % + 0,96 µA 10 Hz do 2 kHz od 1 mA do 10 mA CMC 0,1 % + 9,5 µA 10 Hz do 2 kHz od 10 mA do 100 mA CMC 0,1 % + 96 µA 10 Hz do 2 kHz od 0,1 A do 1 A CMC 0,1 % + 0,95 mA 10 Hz do 2 kHz od 1 A do 10 A CMC 0,1 % + 20 mA Střídavý proud / Měřidla střídavého proudu Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 10 Hz až 2 kHz 0,1 µA až 100 µA CMC 0,1 % + 0,47 µA 10 Hz až 2 kHz 0,1 mA až 1 mA CMC 0,1 % + 0,96 µA 10 Hz až 2 kHz 1 mA až 10 mA CMC 0,1 % + 9,5 µA 10 Hz až 2 kHz 10 mA až 100 mA CMC 0,1 % + 96 µA 10 Hz až 2 kHz 0,1 A až 1 A CMC 0,1 % + 0,95 mA 10 Hz až 2 kHz 1 A až 10 A CMC 0,1 % + 20 mA Kp 04-001, Kp 04-003 Prad przemienny / Mierniki pradu przemiennego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym 10 Hz do 2 kHz od 0,1 µA do 100 µA CMC 0,1 % + 0,47 µA 10 Hz do 2 kHz od 0,1 mA do 1 mA CMC 0,1 % + 0,96 µA 10 Hz do 2 kHz od 1 mA do 10 mA CMC 0,1 % + 9,5 µA 10 Hz do 2 kHz od 10 mA do 100 mA CMC 0,1 % + 96 µA 10 Hz do 2 kHz od 0,1 A do 1 A CMC 0,1 % + 0,95 mA 10 Hz do 2 kHz od 1 A do 10 A CMC 0,1 % + 20 mA Stridavy proud / Meridla stridaveho proudu Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 10 Hz az 2 kHz 0,1 µA az 100 µA CMC 0,1 % + 0,47 µA 10 Hz az 2 kHz 0,1 mA az 1 mA CMC 0,1 % + 0,96 µA 10 Hz az 2 kHz 1 mA az 10 mA CMC 0,1 % + 9,5 µA 10 Hz az 2 kHz 10 mA az 100 mA CMC 0,1 % + 96 µA 10 Hz az 2 kHz 0,1 A az 1 A CMC 0,1 % + 0,95 mA 10 Hz az 2 kHz 1 A az 10 A CMC 0,1 % + 20 mA Kp 04-001, Kp 04-003","search_en":"Alternating current / Alternating current meters Calibration – electrical quantities Direct generation with a reference calibrator 10 Hz to 2 kHz 0,1 µA to 100 µA CMC 0,1 % + 0,47 µA 10 Hz to 2 kHz 0,1 mA to 1 mA CMC 0,1 % + 0,96 µA 10 Hz to 2 kHz 1 mA to 10 mA CMC 0,1 % + 9,5 µA 10 Hz to 2 kHz 10 mA to 100 mA CMC 0,1 % + 96 µA 10 Hz to 2 kHz 0,1 A to 1 A CMC 0,1 % + 0,95 mA 10 Hz to 2 kHz 1 A to 10 A CMC 0,1 % + 20 mA Kp 04-001, Kp 04-003","search_zh":"交流电流 / 交流电流表 校准 – 电学量 用标准校准器直接产生 10 Hz 至 2 kHz 0,1 µA 至 100 µA CMC 0,1 % + 0,47 µA 10 Hz 至 2 kHz 0,1 mA 至 1 mA CMC 0,1 % + 0,96 µA 10 Hz 至 2 kHz 1 mA 至 10 mA CMC 0,1 % + 9,5 µA 10 Hz 至 2 kHz 10 mA 至 100 mA CMC 0,1 % + 96 µA 10 Hz 至 2 kHz 0,1 A 至 1 A CMC 0,1 % + 0,95 mA 10 Hz 至 2 kHz 1 A 至 10 A CMC 0,1 % + 20 mA Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d7d662af6fcaa5c8ed670417","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / Mierniki prądu przemiennego","test_object_en":"Alternating current / Alternating current meters","test_object_zh":"交流电流 / 交流电流表","test_object_cs":"Střídavý proud / Měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"30 Hz do 60 Hz","range":"od 0 A do 20 A","cmc":"0,56 % + 0,12 A"},{"name":"30 Hz do 60 Hz","range":"od 20 A do 100 A","cmc":"0,65 % + 0,17 A"},{"name":"30 Hz do 60 Hz","range":"od 100 A do 500 A","cmc":"0,53 % + 0,53 A"}],"parameters_en":[{"name":"30 Hz to 60 Hz","range":"0 A to 20 A","cmc":"0,56 % + 0,12 A"},{"name":"30 Hz to 60 Hz","range":"20 A to 100 A","cmc":"0,65 % + 0,17 A"},{"name":"30 Hz to 60 Hz","range":"100 A to 500 A","cmc":"0,53 % + 0,53 A"}],"parameters_zh":[{"name":"30 Hz 至 60 Hz","range":"0 A 至 20 A","cmc":"0,56 % + 0,12 A"},{"name":"30 Hz 至 60 Hz","range":"20 A 至 100 A","cmc":"0,65 % + 0,17 A"},{"name":"30 Hz 至 60 Hz","range":"100 A 至 500 A","cmc":"0,53 % + 0,53 A"}],"parameters_cs":[{"name":"30 Hz až 60 Hz","range":"0 A až 20 A","cmc":"0,56 % + 0,12 A"},{"name":"30 Hz až 60 Hz","range":"20 A až 100 A","cmc":"0,65 % + 0,17 A"},{"name":"30 Hz až 60 Hz","range":"100 A až 500 A","cmc":"0,53 % + 0,53 A"}],"technique":"Symulacja prądu wzorcowego kalibratorem i cewką prądową","technique_en":"Reference current simulation with a calibrator and current coil","technique_zh":"用校准器和电流线圈模拟标准电流","technique_cs":"Simulace etalonového proudu kalibrátorem a proudovou cívkou","techniques":["Symulacja prądu wzorcowego kalibratorem i cewką prądową"],"techniques_en":["Reference current simulation with a calibrator and current coil"],"techniques_zh":["用校准器和电流线圈模拟标准电流"],"techniques_cs":["Simulace etalonového proudu kalibrátorem a proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n30 Hz do 60 Hz od 0 A do 20 A CMC 0,56 % + 0,12 A\n30 Hz do 60 Hz od 20 A do 100 A CMC 0,65 % + 0,17 A\n30 Hz do 60 Hz od 100 A do 500 A CMC 0,53 % + 0,53 A\nSymulacja prądu wzorcowego kalibratorem i cewką prądową","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / Mierniki prądu przemiennego Wzorcowanie – wielkości elektryczne Symulacja prądu wzorcowego kalibratorem i cewką prądową 30 Hz do 60 Hz od 0 A do 20 A CMC 0,56 % + 0,12 A 30 Hz do 60 Hz od 20 A do 100 A CMC 0,65 % + 0,17 A 30 Hz do 60 Hz od 100 A do 500 A CMC 0,53 % + 0,53 A Střídavý proud / Měřidla střídavého proudu Kalibrace – elektrické veličiny Simulace etalonového proudu kalibrátorem a proudovou cívkou 30 Hz až 60 Hz 0 A až 20 A CMC 0,56 % + 0,12 A 30 Hz až 60 Hz 20 A až 100 A CMC 0,65 % + 0,17 A 30 Hz až 60 Hz 100 A až 500 A CMC 0,53 % + 0,53 A Kp 04-001, Kp 04-003 Prad przemienny / Mierniki pradu przemiennego Wzorcowanie – wielkosci elektryczne Symulacja pradu wzorcowego kalibratorem i cewka pradowa 30 Hz do 60 Hz od 0 A do 20 A CMC 0,56 % + 0,12 A 30 Hz do 60 Hz od 20 A do 100 A CMC 0,65 % + 0,17 A 30 Hz do 60 Hz od 100 A do 500 A CMC 0,53 % + 0,53 A Stridavy proud / Meridla stridaveho proudu Kalibrace – elektricke veliciny Simulace etalonoveho proudu kalibratorem a proudovou civkou 30 Hz az 60 Hz 0 A az 20 A CMC 0,56 % + 0,12 A 30 Hz az 60 Hz 20 A az 100 A CMC 0,65 % + 0,17 A 30 Hz az 60 Hz 100 A az 500 A CMC 0,53 % + 0,53 A Kp 04-001, Kp 04-003","search_en":"Alternating current / Alternating current meters Calibration – electrical quantities Reference current simulation with a calibrator and current coil 30 Hz to 60 Hz 0 A to 20 A CMC 0,56 % + 0,12 A 30 Hz to 60 Hz 20 A to 100 A CMC 0,65 % + 0,17 A 30 Hz to 60 Hz 100 A to 500 A CMC 0,53 % + 0,53 A Kp 04-001, Kp 04-003","search_zh":"交流电流 / 交流电流表 校准 – 电学量 用校准器和电流线圈模拟标准电流 30 Hz 至 60 Hz 0 A 至 20 A CMC 0,56 % + 0,12 A 30 Hz 至 60 Hz 20 A 至 100 A CMC 0,65 % + 0,17 A 30 Hz 至 60 Hz 100 A 至 500 A CMC 0,53 % + 0,53 A Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f1cca911e5291dff4cd3a651","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja (prąd stały) / Rezystory i dekady rezystancyjne","test_object_en":"DC resistance / resistors and resistance boxes","test_object_zh":"直流电阻 / 电阻器和电阻箱","test_object_cs":"Stejnosměrný odpor / Odpory a odporové dekády","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 10 Ω","cmc":"0,01 % + 12 mΩ"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"0,01 % + 58 mΩ"},{"name":"","range":"od 100 Ω do 1000 Ω","cmc":"0,01 % + 59 mΩ"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,01 % + 0,17 Ω"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"0,01 % + 2,1 Ω"},{"name":"","range":"od 100 kΩ do 1000 kΩ","cmc":"0,01 % + 32 Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,04 % + 1,3 kΩ"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,8 % + 35 kΩ"},{"name":"","range":"od 100 MΩ do 1000 MΩ","cmc":"2,0 % + 0,21 MΩ"}],"parameters_en":[{"name":"","range":"0 Ω to 10 Ω","cmc":"0,01 % + 12 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,01 % + 58 mΩ"},{"name":"","range":"100 Ω to 1000 Ω","cmc":"0,01 % + 59 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,01 % + 0,17 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,01 % + 2,1 Ω"},{"name":"","range":"100 kΩ to 1000 kΩ","cmc":"0,01 % + 32 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,04 % + 1,3 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,8 % + 35 kΩ"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"2,0 % + 0,21 MΩ"}],"parameters_zh":[{"name":"","range":"0 Ω 至 10 Ω","cmc":"0,01 % + 12 mΩ"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"0,01 % + 58 mΩ"},{"name":"","range":"100 Ω 至 1000 Ω","cmc":"0,01 % + 59 mΩ"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,01 % + 0,17 Ω"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"0,01 % + 2,1 Ω"},{"name":"","range":"100 kΩ 至 1000 kΩ","cmc":"0,01 % + 32 Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,04 % + 1,3 kΩ"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,8 % + 35 kΩ"},{"name":"","range":"100 MΩ 至 1000 MΩ","cmc":"2,0 % + 0,21 MΩ"}],"parameters_cs":[{"name":"","range":"0 Ω až 10 Ω","cmc":"0,01 % + 12 mΩ"},{"name":"","range":"10 Ω až 100 Ω","cmc":"0,01 % + 58 mΩ"},{"name":"","range":"100 Ω až 1000 Ω","cmc":"0,01 % + 59 mΩ"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,01 % + 0,17 Ω"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"0,01 % + 2,1 Ω"},{"name":"","range":"100 kΩ až 1000 kΩ","cmc":"0,01 % + 32 Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,04 % + 1,3 kΩ"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,8 % + 35 kΩ"},{"name":"","range":"100 MΩ až 1000 MΩ","cmc":"2,0 % + 0,21 MΩ"}],"technique":"Bezpośredni pomiar multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Bezpośredni pomiar multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 10 Ω CMC 0,01 % + 12 mΩ\nod 10 Ω do 100 Ω CMC 0,01 % + 58 mΩ\nod 100 Ω do 1000 Ω CMC 0,01 % + 59 mΩ\nod 1 kΩ do 10 kΩ CMC 0,01 % + 0,17 Ω\nod 10 kΩ do 100 kΩ CMC 0,01 % + 2,1 Ω\nod 100 kΩ do 1000 kΩ CMC 0,01 % + 32 Ω\nod 1 MΩ do 10 MΩ CMC 0,04 % + 1,3 kΩ\nod 10 MΩ do 100 MΩ CMC 0,8 % + 35 kΩ\nod 100 MΩ do 1000 MΩ CMC 2,0 % + 0,21 MΩ\nBezpośredni pomiar multimetrem wzorcowym","reference":"Kp 04-001, Kp 04-002","norm_bases":["Kp 04-001","Kp 04-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja (prąd stały) / Rezystory i dekady rezystancyjne Wzorcowanie – wielkości elektryczne Bezpośredni pomiar multimetrem wzorcowym od 0 Ω do 10 Ω CMC 0,01 % + 12 mΩ od 10 Ω do 100 Ω CMC 0,01 % + 58 mΩ od 100 Ω do 1000 Ω CMC 0,01 % + 59 mΩ od 1 kΩ do 10 kΩ CMC 0,01 % + 0,17 Ω od 10 kΩ do 100 kΩ CMC 0,01 % + 2,1 Ω od 100 kΩ do 1000 kΩ CMC 0,01 % + 32 Ω od 1 MΩ do 10 MΩ CMC 0,04 % + 1,3 kΩ od 10 MΩ do 100 MΩ CMC 0,8 % + 35 kΩ od 100 MΩ do 1000 MΩ CMC 2,0 % + 0,21 MΩ Stejnosměrný odpor / Odpory a odporové dekády Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 Ω až 10 Ω CMC 0,01 % + 12 mΩ 10 Ω až 100 Ω CMC 0,01 % + 58 mΩ 100 Ω až 1000 Ω CMC 0,01 % + 59 mΩ 1 kΩ až 10 kΩ CMC 0,01 % + 0,17 Ω 10 kΩ až 100 kΩ CMC 0,01 % + 2,1 Ω 100 kΩ až 1000 kΩ CMC 0,01 % + 32 Ω 1 MΩ až 10 MΩ CMC 0,04 % + 1,3 kΩ 10 MΩ až 100 MΩ CMC 0,8 % + 35 kΩ 100 MΩ až 1000 MΩ CMC 2,0 % + 0,21 MΩ Kp 04-001, Kp 04-002 Rezystancja (prad staly) / Rezystory i dekady rezystancyjne Wzorcowanie – wielkosci elektryczne Bezposredni pomiar multimetrem wzorcowym od 0 Ω do 10 Ω CMC 0,01 % + 12 mΩ od 10 Ω do 100 Ω CMC 0,01 % + 58 mΩ od 100 Ω do 1000 Ω CMC 0,01 % + 59 mΩ od 1 kΩ do 10 kΩ CMC 0,01 % + 0,17 Ω od 10 kΩ do 100 kΩ CMC 0,01 % + 2,1 Ω od 100 kΩ do 1000 kΩ CMC 0,01 % + 32 Ω od 1 MΩ do 10 MΩ CMC 0,04 % + 1,3 kΩ od 10 MΩ do 100 MΩ CMC 0,8 % + 35 kΩ od 100 MΩ do 1000 MΩ CMC 2,0 % + 0,21 MΩ Stejnosmerny odpor / Odpory a odporove dekady Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 Ω az 10 Ω CMC 0,01 % + 12 mΩ 10 Ω az 100 Ω CMC 0,01 % + 58 mΩ 100 Ω az 1000 Ω CMC 0,01 % + 59 mΩ 1 kΩ az 10 kΩ CMC 0,01 % + 0,17 Ω 10 kΩ az 100 kΩ CMC 0,01 % + 2,1 Ω 100 kΩ az 1000 kΩ CMC 0,01 % + 32 Ω 1 MΩ az 10 MΩ CMC 0,04 % + 1,3 kΩ 10 MΩ az 100 MΩ CMC 0,8 % + 35 kΩ 100 MΩ az 1000 MΩ CMC 2,0 % + 0,21 MΩ Kp 04-001, Kp 04-002","search_en":"DC resistance / resistors and resistance boxes Calibration – electrical quantities Direct measurement by a reference multimeter 0 Ω to 10 Ω CMC 0,01 % + 12 mΩ 10 Ω to 100 Ω CMC 0,01 % + 58 mΩ 100 Ω to 1000 Ω CMC 0,01 % + 59 mΩ 1 kΩ to 10 kΩ CMC 0,01 % + 0,17 Ω 10 kΩ to 100 kΩ CMC 0,01 % + 2,1 Ω 100 kΩ to 1000 kΩ CMC 0,01 % + 32 Ω 1 MΩ to 10 MΩ CMC 0,04 % + 1,3 kΩ 10 MΩ to 100 MΩ CMC 0,8 % + 35 kΩ 100 MΩ to 1000 MΩ CMC 2,0 % + 0,21 MΩ Kp 04-001, Kp 04-002","search_zh":"直流电阻 / 电阻器和电阻箱 校准 – 电学量 用标准万用表直接测量 0 Ω 至 10 Ω CMC 0,01 % + 12 mΩ 10 Ω 至 100 Ω CMC 0,01 % + 58 mΩ 100 Ω 至 1000 Ω CMC 0,01 % + 59 mΩ 1 kΩ 至 10 kΩ CMC 0,01 % + 0,17 Ω 10 kΩ 至 100 kΩ CMC 0,01 % + 2,1 Ω 100 kΩ 至 1000 kΩ CMC 0,01 % + 32 Ω 1 MΩ 至 10 MΩ CMC 0,04 % + 1,3 kΩ 10 MΩ 至 100 MΩ CMC 0,8 % + 35 kΩ 100 MΩ 至 1000 MΩ CMC 2,0 % + 0,21 MΩ Kp 04-001, Kp 04-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"574a117a13389dc76205b6b6","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja (prąd stały) / Rezystory i dekady rezystancyjne","test_object_en":"DC resistance / resistors and resistance boxes","test_object_zh":"直流电阻 / 电阻器和电阻箱","test_object_cs":"Stejnosměrný odpor / Odpory a odporové dekády","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,01 Ω do 0,1 Ω","cmc":"65µΩ"},{"name":"","range":"od 0,1 Ω do 1 Ω","cmc":"0,052 %"},{"name":"","range":"od 1 Ω do 10 Ω","cmc":"0,14 %"}],"parameters_en":[{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"65µΩ"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,052 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,14 %"}],"parameters_zh":[{"name":"","range":"0,01 Ω 至 0,1 Ω","cmc":"65µΩ"},{"name":"","range":"0,1 Ω 至 1 Ω","cmc":"0,052 %"},{"name":"","range":"1 Ω 至 10 Ω","cmc":"0,14 %"}],"parameters_cs":[{"name":"","range":"0,01 Ω až 0,1 Ω","cmc":"65µΩ"},{"name":"","range":"0,1 Ω až 1 Ω","cmc":"0,052 %"},{"name":"","range":"1 Ω až 10 Ω","cmc":"0,14 %"}],"technique":"Pomiar pośredni – metoda woltomierzowo-amperomierzowa","technique_en":"Indirect measurement – volt – ampere method","technique_zh":"间接测量 – 伏安法","technique_cs":"Nepřímé měření – volt – ampérová metoda","techniques":["Pomiar pośredni – metoda woltomierzowo-amperomierzowa"],"techniques_en":["Indirect measurement – volt – ampere method"],"techniques_zh":["间接测量 – 伏安法"],"techniques_cs":["Nepřímé měření – volt – ampérová metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,01 Ω do 0,1 Ω CMC 65µΩ\nod 0,1 Ω do 1 Ω CMC 0,052 %\nod 1 Ω do 10 Ω CMC 0,14 %\nPomiar pośredni – metoda woltomierzowo-amperomierzowa","reference":"Kp 04-002","norm_bases":["Kp 04-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja (prąd stały) / Rezystory i dekady rezystancyjne Wzorcowanie – wielkości elektryczne Pomiar pośredni – metoda woltomierzowo-amperomierzowa od 0,01 Ω do 0,1 Ω CMC 65µΩ od 0,1 Ω do 1 Ω CMC 0,052 % od 1 Ω do 10 Ω CMC 0,14 % Stejnosměrný odpor / Odpory a odporové dekády Kalibrace – elektrické veličiny Nepřímé měření – volt – ampérová metoda 0,01 Ω až 0,1 Ω CMC 65µΩ 0,1 Ω až 1 Ω CMC 0,052 % 1 Ω až 10 Ω CMC 0,14 % Kp 04-002 Rezystancja (prad staly) / Rezystory i dekady rezystancyjne Wzorcowanie – wielkosci elektryczne Pomiar posredni – metoda woltomierzowo-amperomierzowa od 0,01 Ω do 0,1 Ω CMC 65µΩ od 0,1 Ω do 1 Ω CMC 0,052 % od 1 Ω do 10 Ω CMC 0,14 % Stejnosmerny odpor / Odpory a odporove dekady Kalibrace – elektricke veliciny Neprime mereni – volt – amperova metoda 0,01 Ω az 0,1 Ω CMC 65µΩ 0,1 Ω az 1 Ω CMC 0,052 % 1 Ω az 10 Ω CMC 0,14 % Kp 04-002","search_en":"DC resistance / resistors and resistance boxes Calibration – electrical quantities Indirect measurement – volt – ampere method 0,01 Ω to 0,1 Ω CMC 65µΩ 0,1 Ω to 1 Ω CMC 0,052 % 1 Ω to 10 Ω CMC 0,14 % Kp 04-002","search_zh":"直流电阻 / 电阻器和电阻箱 校准 – 电学量 间接测量 – 伏安法 0,01 Ω 至 0,1 Ω CMC 65µΩ 0,1 Ω 至 1 Ω CMC 0,052 % 1 Ω 至 10 Ω CMC 0,14 % Kp 04-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"00ad2f87f0f30903f088da4e","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja (prąd stały) / Mierniki rezystancji","test_object_en":"DC resistance / DC resistance meters","test_object_zh":"直流电阻 / 直流电阻表","test_object_cs":"Stejnosměrný odpor / Měřidla stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"1 mΩ","cmc":"2,4 µΩ"},{"name":"","range":"10 mΩ","cmc":"24 µΩ"},{"name":"","range":"od 0,01 Ω do 0,1 Ω","cmc":"2 % + 0,10 mΩ"},{"name":"","range":"od 0,1 Ω do 1 Ω","cmc":"0,2 % + 0,54 mΩ"}],"parameters_en":[{"name":"","range":"1 mΩ","cmc":"2,4 µΩ"},{"name":"","range":"10 mΩ","cmc":"24 µΩ"},{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"2 % + 0,10 mΩ"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,2 % + 0,54 mΩ"}],"parameters_zh":[{"name":"","range":"1 mΩ","cmc":"2,4 µΩ"},{"name":"","range":"10 mΩ","cmc":"24 µΩ"},{"name":"","range":"0,01 Ω 至 0,1 Ω","cmc":"2 % + 0,10 mΩ"},{"name":"","range":"0,1 Ω 至 1 Ω","cmc":"0,2 % + 0,54 mΩ"}],"parameters_cs":[{"name":"","range":"1 mΩ","cmc":"2,4 µΩ"},{"name":"","range":"10 mΩ","cmc":"24 µΩ"},{"name":"","range":"0,01 Ω až 0,1 Ω","cmc":"2 % + 0,10 mΩ"},{"name":"","range":"0,1 Ω až 1 Ω","cmc":"0,2 % + 0,54 mΩ"}],"technique":"Bezpośredni pomiar wzorcowej dekady rezystancyjnej lub wzorców rezystancji","technique_en":"Direct measurement of a reference resistance box or resistance standards","technique_zh":"直接测量标准电阻箱或标准电阻","technique_cs":"Přímé měření etalonové odporové dekády nebo odporových normálů","techniques":["Bezpośredni pomiar wzorcowej dekady rezystancyjnej lub wzorców rezystancji"],"techniques_en":["Direct measurement of a reference resistance box or resistance standards"],"techniques_zh":["直接测量标准电阻箱或标准电阻"],"techniques_cs":["Přímé měření etalonové odporové dekády nebo odporových normálů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 mΩ CMC 2,4 µΩ\n10 mΩ CMC 24 µΩ\nod 0,01 Ω do 0,1 Ω CMC 2 % + 0,10 mΩ\nod 0,1 Ω do 1 Ω CMC 0,2 % + 0,54 mΩ\nBezpośredni pomiar wzorcowej dekady rezystancyjnej lub wzorców rezystancji","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja (prąd stały) / Mierniki rezystancji Wzorcowanie – wielkości elektryczne Bezpośredni pomiar wzorcowej dekady rezystancyjnej lub wzorców rezystancji 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ od 0,01 Ω do 0,1 Ω CMC 2 % + 0,10 mΩ od 0,1 Ω do 1 Ω CMC 0,2 % + 0,54 mΩ Stejnosměrný odpor / Měřidla stejnosměrného odporu Kalibrace – elektrické veličiny Přímé měření etalonové odporové dekády nebo odporových normálů 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ 0,01 Ω až 0,1 Ω CMC 2 % + 0,10 mΩ 0,1 Ω až 1 Ω CMC 0,2 % + 0,54 mΩ Kp 04-001, Kp 04-003 Rezystancja (prad staly) / Mierniki rezystancji Wzorcowanie – wielkosci elektryczne Bezposredni pomiar wzorcowej dekady rezystancyjnej lub wzorcow rezystancji 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ od 0,01 Ω do 0,1 Ω CMC 2 % + 0,10 mΩ od 0,1 Ω do 1 Ω CMC 0,2 % + 0,54 mΩ Stejnosmerny odpor / Meridla stejnosmerneho odporu Kalibrace – elektricke veliciny Prime mereni etalonove odporove dekady nebo odporovych normalu 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ 0,01 Ω az 0,1 Ω CMC 2 % + 0,10 mΩ 0,1 Ω az 1 Ω CMC 0,2 % + 0,54 mΩ Kp 04-001, Kp 04-003","search_en":"DC resistance / DC resistance meters Calibration – electrical quantities Direct measurement of a reference resistance box or resistance standards 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ 0,01 Ω to 0,1 Ω CMC 2 % + 0,10 mΩ 0,1 Ω to 1 Ω CMC 0,2 % + 0,54 mΩ Kp 04-001, Kp 04-003","search_zh":"直流电阻 / 直流电阻表 校准 – 电学量 直接测量标准电阻箱或标准电阻 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ 0,01 Ω 至 0,1 Ω CMC 2 % + 0,10 mΩ 0,1 Ω 至 1 Ω CMC 0,2 % + 0,54 mΩ Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6fdfdaca50dbaab9c2beb906","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja (prąd stały) / Mierniki rezystancji","test_object_en":"DC resistance / DC resistance meters","test_object_zh":"直流电阻 / 直流电阻表","test_object_cs":"Stejnosměrný odpor / Měřidla stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 Ω do 10 Ω","cmc":"20 mΩ"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"40 mΩ"},{"name":"","range":"od 100 Ω do 1 kΩ","cmc":"0,27 Ω"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"2,4 Ω"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"24 Ω"},{"name":"","range":"od 0,1 MΩ do 1 MΩ","cmc":"0,24 kΩ"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"5,8 kΩ"},{"name":"","range":"od 100 MΩ do 2000 MΩ","cmc":"1,3 % + 5,8 kΩ"}],"parameters_en":[{"name":"","range":"1 Ω to 10 Ω","cmc":"20 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"40 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,27 Ω"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"2,4 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"24 Ω"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,24 kΩ"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"5,8 kΩ"},{"name":"","range":"100 MΩ to 2000 MΩ","cmc":"1,3 % + 5,8 kΩ"}],"parameters_zh":[{"name":"","range":"1 Ω 至 10 Ω","cmc":"20 mΩ"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"40 mΩ"},{"name":"","range":"100 Ω 至 1 kΩ","cmc":"0,27 Ω"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"2,4 Ω"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"24 Ω"},{"name":"","range":"0,1 MΩ 至 1 MΩ","cmc":"0,24 kΩ"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"5,8 kΩ"},{"name":"","range":"100 MΩ 至 2000 MΩ","cmc":"1,3 % + 5,8 kΩ"}],"parameters_cs":[{"name":"","range":"1 Ω až 10 Ω","cmc":"20 mΩ"},{"name":"","range":"10 Ω až 100 Ω","cmc":"40 mΩ"},{"name":"","range":"100 Ω až 1 kΩ","cmc":"0,27 Ω"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"2,4 Ω"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"24 Ω"},{"name":"","range":"0,1 MΩ až 1 MΩ","cmc":"0,24 kΩ"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"5,8 kΩ"},{"name":"","range":"100 MΩ až 2000 MΩ","cmc":"1,3 % + 5,8 kΩ"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a reference calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a reference calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 Ω do 10 Ω CMC 20 mΩ\nod 10 Ω do 100 Ω CMC 40 mΩ\nod 100 Ω do 1 kΩ CMC 0,27 Ω\nod 1 kΩ do 10 kΩ CMC 2,4 Ω\nod 10 kΩ do 100 kΩ CMC 24 Ω\nod 0,1 MΩ do 1 MΩ CMC 0,24 kΩ\nod 1 MΩ do 10 MΩ CMC 5,8 kΩ\nod 100 MΩ do 2000 MΩ CMC 1,3 % + 5,8 kΩ\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja (prąd stały) / Mierniki rezystancji Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym od 1 Ω do 10 Ω CMC 20 mΩ od 10 Ω do 100 Ω CMC 40 mΩ od 100 Ω do 1 kΩ CMC 0,27 Ω od 1 kΩ do 10 kΩ CMC 2,4 Ω od 10 kΩ do 100 kΩ CMC 24 Ω od 0,1 MΩ do 1 MΩ CMC 0,24 kΩ od 1 MΩ do 10 MΩ CMC 5,8 kΩ od 100 MΩ do 2000 MΩ CMC 1,3 % + 5,8 kΩ Stejnosměrný odpor / Měřidla stejnosměrného odporu Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 1 Ω až 10 Ω CMC 20 mΩ 10 Ω až 100 Ω CMC 40 mΩ 100 Ω až 1 kΩ CMC 0,27 Ω 1 kΩ až 10 kΩ CMC 2,4 Ω 10 kΩ až 100 kΩ CMC 24 Ω 0,1 MΩ až 1 MΩ CMC 0,24 kΩ 1 MΩ až 10 MΩ CMC 5,8 kΩ 100 MΩ až 2000 MΩ CMC 1,3 % + 5,8 kΩ Kp 04-001, Kp 04-003 Rezystancja (prad staly) / Mierniki rezystancji Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym od 1 Ω do 10 Ω CMC 20 mΩ od 10 Ω do 100 Ω CMC 40 mΩ od 100 Ω do 1 kΩ CMC 0,27 Ω od 1 kΩ do 10 kΩ CMC 2,4 Ω od 10 kΩ do 100 kΩ CMC 24 Ω od 0,1 MΩ do 1 MΩ CMC 0,24 kΩ od 1 MΩ do 10 MΩ CMC 5,8 kΩ od 100 MΩ do 2000 MΩ CMC 1,3 % + 5,8 kΩ Stejnosmerny odpor / Meridla stejnosmerneho odporu Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 1 Ω az 10 Ω CMC 20 mΩ 10 Ω az 100 Ω CMC 40 mΩ 100 Ω az 1 kΩ CMC 0,27 Ω 1 kΩ az 10 kΩ CMC 2,4 Ω 10 kΩ az 100 kΩ CMC 24 Ω 0,1 MΩ az 1 MΩ CMC 0,24 kΩ 1 MΩ az 10 MΩ CMC 5,8 kΩ 100 MΩ az 2000 MΩ CMC 1,3 % + 5,8 kΩ Kp 04-001, Kp 04-003","search_en":"DC resistance / DC resistance meters Calibration – electrical quantities Direct generation with a reference calibrator 1 Ω to 10 Ω CMC 20 mΩ 10 Ω to 100 Ω CMC 40 mΩ 100 Ω to 1 kΩ CMC 0,27 Ω 1 kΩ to 10 kΩ CMC 2,4 Ω 10 kΩ to 100 kΩ CMC 24 Ω 0,1 MΩ to 1 MΩ CMC 0,24 kΩ 1 MΩ to 10 MΩ CMC 5,8 kΩ 100 MΩ to 2000 MΩ CMC 1,3 % + 5,8 kΩ Kp 04-001, Kp 04-003","search_zh":"直流电阻 / 直流电阻表 校准 – 电学量 用标准校准器直接产生 1 Ω 至 10 Ω CMC 20 mΩ 10 Ω 至 100 Ω CMC 40 mΩ 100 Ω 至 1 kΩ CMC 0,27 Ω 1 kΩ 至 10 kΩ CMC 2,4 Ω 10 kΩ 至 100 kΩ CMC 24 Ω 0,1 MΩ 至 1 MΩ CMC 0,24 kΩ 1 MΩ 至 10 MΩ CMC 5,8 kΩ 100 MΩ 至 2000 MΩ CMC 1,3 % + 5,8 kΩ Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0905c434b0ff989c0ed1b7f3","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja (prąd stały) / Mierniki rezystancji","test_object_en":"DC resistance / DC resistance meters","test_object_zh":"直流电阻 / 直流电阻表","test_object_cs":"Stejnosměrný odpor / Měřidla stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,1 MΩ do 0,5 MΩ","cmc":"0,05 % + 10 Ω"},{"name":"","range":"od 0,6 MΩ do 0,9 MΩ","cmc":"0,05 % + 15 Ω"},{"name":"","range":"od 1 MΩ do 5 MΩ","cmc":"0,05 % + 0,25 kΩ"},{"name":"","range":"od 6 MΩ do 9 MΩ","cmc":"0,05 % + 0,35 kΩ"},{"name":"","range":"od 10 MΩ do 50 MΩ","cmc":"0,1 % + 2,5 kΩ"},{"name":"","range":"od 50 MΩ do 100 MΩ","cmc":"0,1 % + 9 kΩ"}],"parameters_en":[{"name":"","range":"0,1 MΩ to 0,5 MΩ","cmc":"0,05 % + 10 Ω"},{"name":"","range":"0,6 MΩ to 0,9 MΩ","cmc":"0,05 % + 15 Ω"},{"name":"","range":"1 MΩ to 5 MΩ","cmc":"0,05 % + 0,25 kΩ"},{"name":"","range":"6 MΩ to 9 MΩ","cmc":"0,05 % + 0,35 kΩ"},{"name":"","range":"10 MΩ to 50 MΩ","cmc":"0,1 % + 2,5 kΩ"},{"name":"","range":"50 MΩ to 100 MΩ","cmc":"0,1 % + 9 kΩ"}],"parameters_zh":[{"name":"","range":"0,1 MΩ 至 0,5 MΩ","cmc":"0,05 % + 10 Ω"},{"name":"","range":"0,6 MΩ 至 0,9 MΩ","cmc":"0,05 % + 15 Ω"},{"name":"","range":"1 MΩ 至 5 MΩ","cmc":"0,05 % + 0,25 kΩ"},{"name":"","range":"6 MΩ 至 9 MΩ","cmc":"0,05 % + 0,35 kΩ"},{"name":"","range":"10 MΩ 至 50 MΩ","cmc":"0,1 % + 2,5 kΩ"},{"name":"","range":"50 MΩ 至 100 MΩ","cmc":"0,1 % + 9 kΩ"}],"parameters_cs":[{"name":"","range":"0,1 MΩ až 0,5 MΩ","cmc":"0,05 % + 10 Ω"},{"name":"","range":"0,6 MΩ až 0,9 MΩ","cmc":"0,05 % + 15 Ω"},{"name":"","range":"1 MΩ až 5 MΩ","cmc":"0,05 % + 0,25 kΩ"},{"name":"","range":"6 MΩ až 9 MΩ","cmc":"0,05 % + 0,35 kΩ"},{"name":"","range":"10 MΩ až 50 MΩ","cmc":"0,1 % + 2,5 kΩ"},{"name":"","range":"50 MΩ až 100 MΩ","cmc":"0,1 % + 9 kΩ"}],"technique":"Bezpośrednie generowanie wzorcową dekadą rezystancyjną","technique_en":"Direct generation using a reference resistance box","technique_zh":"用标准电阻箱直接产生","technique_cs":"Přímé generování etalonovou odporovou dekádou","techniques":["Bezpośrednie generowanie wzorcową dekadą rezystancyjną"],"techniques_en":["Direct generation using a reference resistance box"],"techniques_zh":["用标准电阻箱直接产生"],"techniques_cs":["Přímé generování etalonovou odporovou dekádou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,1 MΩ do 0,5 MΩ CMC 0,05 % + 10 Ω\nod 0,6 MΩ do 0,9 MΩ CMC 0,05 % + 15 Ω\nod 1 MΩ do 5 MΩ CMC 0,05 % + 0,25 kΩ\nod 6 MΩ do 9 MΩ CMC 0,05 % + 0,35 kΩ\nod 10 MΩ do 50 MΩ CMC 0,1 % + 2,5 kΩ\nod 50 MΩ do 100 MΩ CMC 0,1 % + 9 kΩ\nBezpośrednie generowanie wzorcową dekadą rezystancyjną","reference":"Kp 04-001, Kp 04-003","norm_bases":["Kp 04-001","Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja (prąd stały) / Mierniki rezystancji Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie wzorcową dekadą rezystancyjną od 0,1 MΩ do 0,5 MΩ CMC 0,05 % + 10 Ω od 0,6 MΩ do 0,9 MΩ CMC 0,05 % + 15 Ω od 1 MΩ do 5 MΩ CMC 0,05 % + 0,25 kΩ od 6 MΩ do 9 MΩ CMC 0,05 % + 0,35 kΩ od 10 MΩ do 50 MΩ CMC 0,1 % + 2,5 kΩ od 50 MΩ do 100 MΩ CMC 0,1 % + 9 kΩ Stejnosměrný odpor / Měřidla stejnosměrného odporu Kalibrace – elektrické veličiny Přímé generování etalonovou odporovou dekádou 0,1 MΩ až 0,5 MΩ CMC 0,05 % + 10 Ω 0,6 MΩ až 0,9 MΩ CMC 0,05 % + 15 Ω 1 MΩ až 5 MΩ CMC 0,05 % + 0,25 kΩ 6 MΩ až 9 MΩ CMC 0,05 % + 0,35 kΩ 10 MΩ až 50 MΩ CMC 0,1 % + 2,5 kΩ 50 MΩ až 100 MΩ CMC 0,1 % + 9 kΩ Kp 04-001, Kp 04-003 Rezystancja (prad staly) / Mierniki rezystancji Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie wzorcowa dekada rezystancyjna od 0,1 MΩ do 0,5 MΩ CMC 0,05 % + 10 Ω od 0,6 MΩ do 0,9 MΩ CMC 0,05 % + 15 Ω od 1 MΩ do 5 MΩ CMC 0,05 % + 0,25 kΩ od 6 MΩ do 9 MΩ CMC 0,05 % + 0,35 kΩ od 10 MΩ do 50 MΩ CMC 0,1 % + 2,5 kΩ od 50 MΩ do 100 MΩ CMC 0,1 % + 9 kΩ Stejnosmerny odpor / Meridla stejnosmerneho odporu Kalibrace – elektricke veliciny Prime generovani etalonovou odporovou dekadou 0,1 MΩ az 0,5 MΩ CMC 0,05 % + 10 Ω 0,6 MΩ az 0,9 MΩ CMC 0,05 % + 15 Ω 1 MΩ az 5 MΩ CMC 0,05 % + 0,25 kΩ 6 MΩ az 9 MΩ CMC 0,05 % + 0,35 kΩ 10 MΩ az 50 MΩ CMC 0,1 % + 2,5 kΩ 50 MΩ az 100 MΩ CMC 0,1 % + 9 kΩ Kp 04-001, Kp 04-003","search_en":"DC resistance / DC resistance meters Calibration – electrical quantities Direct generation using a reference resistance box 0,1 MΩ to 0,5 MΩ CMC 0,05 % + 10 Ω 0,6 MΩ to 0,9 MΩ CMC 0,05 % + 15 Ω 1 MΩ to 5 MΩ CMC 0,05 % + 0,25 kΩ 6 MΩ to 9 MΩ CMC 0,05 % + 0,35 kΩ 10 MΩ to 50 MΩ CMC 0,1 % + 2,5 kΩ 50 MΩ to 100 MΩ CMC 0,1 % + 9 kΩ Kp 04-001, Kp 04-003","search_zh":"直流电阻 / 直流电阻表 校准 – 电学量 用标准电阻箱直接产生 0,1 MΩ 至 0,5 MΩ CMC 0,05 % + 10 Ω 0,6 MΩ 至 0,9 MΩ CMC 0,05 % + 15 Ω 1 MΩ 至 5 MΩ CMC 0,05 % + 0,25 kΩ 6 MΩ 至 9 MΩ CMC 0,05 % + 0,35 kΩ 10 MΩ 至 50 MΩ CMC 0,1 % + 2,5 kΩ 50 MΩ 至 100 MΩ CMC 0,1 % + 9 kΩ Kp 04-001, Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":87,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"19510ebc05144541cd1b6993","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"6","test_object":"Rezystancja przejścia / Przyrządy do badań instalacji","test_object_en":"Transition resistance / Inspection instruments","test_object_zh":"过渡电阻 / 检验仪器","test_object_cs":"Přechodový odpor / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"1 mΩ","cmc":"2,4 µΩ"},{"name":"","range":"10 mΩ","cmc":"24 µΩ"},{"name":"","range":"od 0,01 Ω do 0,09 Ω","cmc":"2 % + 0,10 mΩ"},{"name":"","range":"od 0,1 Ω do 1 Ω","cmc":"0,2 % + 0,54 mΩ"},{"name":"","range":"od 1 Ω do 10 Ω","cmc":"0,1 % + 14 mΩ"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"0,05 % + 70 mΩ"},{"name":"","range":"od 100 Ω do 1000 Ω","cmc":"0,05 % + 180 mΩ"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,05 % + 1,4 Ω"}],"parameters_en":[{"name":"","range":"1 mΩ","cmc":"2,4 µΩ"},{"name":"","range":"10 mΩ","cmc":"24 µΩ"},{"name":"","range":"0,01 Ω to 0,09 Ω","cmc":"2 % + 0,10 mΩ"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,2 % + 0,54 mΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,1 % + 14 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,05 % + 70 mΩ"},{"name":"","range":"100 Ω to 1000 Ω","cmc":"0,05 % + 180 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,05 % + 1,4 Ω"}],"parameters_zh":[{"name":"","range":"1 mΩ","cmc":"2,4 µΩ"},{"name":"","range":"10 mΩ","cmc":"24 µΩ"},{"name":"","range":"0,01 Ω 至 0,09 Ω","cmc":"2 % + 0,10 mΩ"},{"name":"","range":"0,1 Ω 至 1 Ω","cmc":"0,2 % + 0,54 mΩ"},{"name":"","range":"1 Ω 至 10 Ω","cmc":"0,1 % + 14 mΩ"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"0,05 % + 70 mΩ"},{"name":"","range":"100 Ω 至 1000 Ω","cmc":"0,05 % + 180 mΩ"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,05 % + 1,4 Ω"}],"parameters_cs":[{"name":"","range":"1 mΩ","cmc":"2,4 µΩ"},{"name":"","range":"10 mΩ","cmc":"24 µΩ"},{"name":"","range":"0,01 Ω až 0,09 Ω","cmc":"2 % + 0,10 mΩ"},{"name":"","range":"0,1 Ω až 1 Ω","cmc":"0,2 % + 0,54 mΩ"},{"name":"","range":"1 Ω až 10 Ω","cmc":"0,1 % + 14 mΩ"},{"name":"","range":"10 Ω až 100 Ω","cmc":"0,05 % + 70 mΩ"},{"name":"","range":"100 Ω až 1000 Ω","cmc":"0,05 % + 180 mΩ"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,05 % + 1,4 Ω"}],"technique":"Bezpośrednie generowanie wzorcową dekadą rezystancyjną lub wzorcami rezystancji","technique_en":"Direct generation by a reference resistance box or resistance standards","technique_zh":"用标准电阻箱或标准电阻直接产生","technique_cs":"Přímé generování etalonovou odporovou dekádou nebo odporovými normály","techniques":["Bezpośrednie generowanie wzorcową dekadą rezystancyjną lub wzorcami rezystancji"],"techniques_en":["Direct generation by a reference resistance box or resistance standards"],"techniques_zh":["用标准电阻箱或标准电阻直接产生"],"techniques_cs":["Přímé generování etalonovou odporovou dekádou nebo odporovými normály"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 mΩ CMC 2,4 µΩ\n10 mΩ CMC 24 µΩ\nod 0,01 Ω do 0,09 Ω CMC 2 % + 0,10 mΩ\nod 0,1 Ω do 1 Ω CMC 0,2 % + 0,54 mΩ\nod 1 Ω do 10 Ω CMC 0,1 % + 14 mΩ\nod 10 Ω do 100 Ω CMC 0,05 % + 70 mΩ\nod 100 Ω do 1000 Ω CMC 0,05 % + 180 mΩ\nod 1 kΩ do 10 kΩ CMC 0,05 % + 1,4 Ω\nBezpośrednie generowanie wzorcową dekadą rezystancyjną lub wzorcami rezystancji","reference":"Kp 04-003","norm_bases":["Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przejścia / Przyrządy do badań instalacji Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie wzorcową dekadą rezystancyjną lub wzorcami rezystancji 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ od 0,01 Ω do 0,09 Ω CMC 2 % + 0,10 mΩ od 0,1 Ω do 1 Ω CMC 0,2 % + 0,54 mΩ od 1 Ω do 10 Ω CMC 0,1 % + 14 mΩ od 10 Ω do 100 Ω CMC 0,05 % + 70 mΩ od 100 Ω do 1000 Ω CMC 0,05 % + 180 mΩ od 1 kΩ do 10 kΩ CMC 0,05 % + 1,4 Ω Přechodový odpor / Revizní přístroje Kalibrace – elektrické veličiny Přímé generování etalonovou odporovou dekádou nebo odporovými normály 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ 0,01 Ω až 0,09 Ω CMC 2 % + 0,10 mΩ 0,1 Ω až 1 Ω CMC 0,2 % + 0,54 mΩ 1 Ω až 10 Ω CMC 0,1 % + 14 mΩ 10 Ω až 100 Ω CMC 0,05 % + 70 mΩ 100 Ω až 1000 Ω CMC 0,05 % + 180 mΩ 1 kΩ až 10 kΩ CMC 0,05 % + 1,4 Ω Kp 04-003 Rezystancja przejscia / Przyrzady do badan instalacji Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie wzorcowa dekada rezystancyjna lub wzorcami rezystancji 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ od 0,01 Ω do 0,09 Ω CMC 2 % + 0,10 mΩ od 0,1 Ω do 1 Ω CMC 0,2 % + 0,54 mΩ od 1 Ω do 10 Ω CMC 0,1 % + 14 mΩ od 10 Ω do 100 Ω CMC 0,05 % + 70 mΩ od 100 Ω do 1000 Ω CMC 0,05 % + 180 mΩ od 1 kΩ do 10 kΩ CMC 0,05 % + 1,4 Ω Prechodovy odpor / Revizni pristroje Kalibrace – elektricke veliciny Prime generovani etalonovou odporovou dekadou nebo odporovymi normaly 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ 0,01 Ω az 0,09 Ω CMC 2 % + 0,10 mΩ 0,1 Ω az 1 Ω CMC 0,2 % + 0,54 mΩ 1 Ω az 10 Ω CMC 0,1 % + 14 mΩ 10 Ω az 100 Ω CMC 0,05 % + 70 mΩ 100 Ω az 1000 Ω CMC 0,05 % + 180 mΩ 1 kΩ az 10 kΩ CMC 0,05 % + 1,4 Ω Kp 04-003","search_en":"Transition resistance / Inspection instruments Calibration – electrical quantities Direct generation by a reference resistance box or resistance standards 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ 0,01 Ω to 0,09 Ω CMC 2 % + 0,10 mΩ 0,1 Ω to 1 Ω CMC 0,2 % + 0,54 mΩ 1 Ω to 10 Ω CMC 0,1 % + 14 mΩ 10 Ω to 100 Ω CMC 0,05 % + 70 mΩ 100 Ω to 1000 Ω CMC 0,05 % + 180 mΩ 1 kΩ to 10 kΩ CMC 0,05 % + 1,4 Ω Kp 04-003","search_zh":"过渡电阻 / 检验仪器 校准 – 电学量 用标准电阻箱或标准电阻直接产生 1 mΩ CMC 2,4 µΩ 10 mΩ CMC 24 µΩ 0,01 Ω 至 0,09 Ω CMC 2 % + 0,10 mΩ 0,1 Ω 至 1 Ω CMC 0,2 % + 0,54 mΩ 1 Ω 至 10 Ω CMC 0,1 % + 14 mΩ 10 Ω 至 100 Ω CMC 0,05 % + 70 mΩ 100 Ω 至 1000 Ω CMC 0,05 % + 180 mΩ 1 kΩ 至 10 kΩ CMC 0,05 % + 1,4 Ω Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":88,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5698dd035d54e4e25062d485","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"7","test_object":"Rezystancja izolacji / Przyrządy do badań instalacji","test_object_en":"Insulation resistance / Inspection instruments","test_object_zh":"绝缘电阻 / 检验仪器","test_object_cs":"Izolační odpor / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"Napięcie pomiarowe do 100 V","range":"od 10 kΩ do 100 kΩ","cmc":"0,05 % + 14 Ω"},{"name":"Napięcie pomiarowe do 100 V","range":"od 0,1 MΩ do 0,5 MΩ","cmc":"0,05 % + 10 Ω"},{"name":"Napięcie pomiarowe do 100 V","range":"od 0,6 MΩ do 0,9 MΩ","cmc":"0,05 % + 15 Ω"},{"name":"Napięcie pomiarowe do 500 V","range":"od 1 MΩ do 5 MΩ","cmc":"0,05 % + 0,25 kΩ"},{"name":"Napięcie pomiarowe do 500 V","range":"od 6 MΩ do 9 MΩ","cmc":"0,05 % + 0,35 kΩ"},{"name":"Napięcie pomiarowe do 1000 V","range":"od 10 MΩ do 50 MΩ","cmc":"0,1 % + 2,5 kΩ"},{"name":"Napięcie pomiarowe do 1000 V","range":"od 50 MΩ do 100 MΩ","cmc":"0,1 % + 9,0 kΩ"},{"name":"Napięcie pomiarowe do 5000 V","range":"od 100 MΩ do 1000 MΩ","cmc":"1,2 %"},{"name":"Napięcie pomiarowe do 5000 V","range":"od 1 GΩ do 10 GΩ","cmc":"1,2 %"}],"parameters_en":[{"name":"Measuring voltage up to 100 V","range":"10 kΩ to 100 kΩ","cmc":"0,05 % + 14 Ω"},{"name":"Measuring voltage up to 100 V","range":"0,1 MΩ to 0,5 MΩ","cmc":"0,05 % + 10 Ω"},{"name":"Measuring voltage up to 100 V","range":"0,6 MΩ to 0,9 MΩ","cmc":"0,05 % + 15 Ω"},{"name":"Measuring voltage up to 500 V","range":"1 MΩ to 5 MΩ","cmc":"0,05 % + 0,25 kΩ"},{"name":"Measuring voltage up to 500 V","range":"6 MΩ to 9 MΩ","cmc":"0,05 % + 0,35 kΩ"},{"name":"Measuring voltage up to 1,000 V","range":"10 MΩ to 50 MΩ","cmc":"0,1 % + 2,5 kΩ"},{"name":"Measuring voltage up to 1,000 V","range":"50 MΩ to 100 MΩ","cmc":"0,1 % + 9,0 kΩ"},{"name":"Measuring voltage up to 5,000 V","range":"100 MΩ to 1000 MΩ","cmc":"1,2 %"},{"name":"Measuring voltage up to 5,000 V","range":"1 GΩ to 10 GΩ","cmc":"1,2 %"}],"parameters_zh":[{"name":"测量电压不超过 100 V","range":"10 kΩ 至 100 kΩ","cmc":"0,05 % + 14 Ω"},{"name":"测量电压不超过 100 V","range":"0,1 MΩ 至 0,5 MΩ","cmc":"0,05 % + 10 Ω"},{"name":"测量电压不超过 100 V","range":"0,6 MΩ 至 0,9 MΩ","cmc":"0,05 % + 15 Ω"},{"name":"测量电压不超过 500 V","range":"1 MΩ 至 5 MΩ","cmc":"0,05 % + 0,25 kΩ"},{"name":"测量电压不超过 500 V","range":"6 MΩ 至 9 MΩ","cmc":"0,05 % + 0,35 kΩ"},{"name":"测量电压不超过 1000 V","range":"10 MΩ 至 50 MΩ","cmc":"0,1 % + 2,5 kΩ"},{"name":"测量电压不超过 1000 V","range":"50 MΩ 至 100 MΩ","cmc":"0,1 % + 9,0 kΩ"},{"name":"测量电压不超过 5000 V","range":"100 MΩ 至 1000 MΩ","cmc":"1,2 %"},{"name":"测量电压不超过 5000 V","range":"1 GΩ 至 10 GΩ","cmc":"1,2 %"}],"parameters_cs":[{"name":"Měřící napětí do 100 V","range":"10 kΩ až 100 kΩ","cmc":"0,05 % + 14 Ω"},{"name":"Měřící napětí do 100 V","range":"0,1 MΩ až 0,5 MΩ","cmc":"0,05 % + 10 Ω"},{"name":"Měřící napětí do 100 V","range":"0,6 MΩ až 0,9 MΩ","cmc":"0,05 % + 15 Ω"},{"name":"Měřící napětí do 500 V","range":"1 MΩ až 5 MΩ","cmc":"0,05 % + 0,25 kΩ"},{"name":"Měřící napětí do 500 V","range":"6 MΩ až 9 MΩ","cmc":"0,05 % + 0,35 kΩ"},{"name":"Měřící napětí do 1000 V","range":"10 MΩ až 50 MΩ","cmc":"0,1 % + 2,5 kΩ"},{"name":"Měřící napětí do 1000 V","range":"50 MΩ až 100 MΩ","cmc":"0,1 % + 9,0 kΩ"},{"name":"Měřící napětí do 5000 V","range":"100 MΩ až 1000 MΩ","cmc":"1,2 %"},{"name":"Měřící napětí do 5000 V","range":"1 GΩ až 10 GΩ","cmc":"1,2 %"}],"technique":"Bezpośredni pomiar wzorcowej dekady rezystancyjnej","technique_en":"Direct measurement of a reference resistance box","technique_zh":"直接测量标准电阻箱","technique_cs":"Přímé měření etalonové odporové dekády","techniques":["Bezpośredni pomiar wzorcowej dekady rezystancyjnej"],"techniques_en":["Direct measurement of a reference resistance box"],"techniques_zh":["直接测量标准电阻箱"],"techniques_cs":["Přímé měření etalonové odporové dekády"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nNapięcie pomiarowe do 100 V od 10 kΩ do 100 kΩ CMC 0,05 % + 14 Ω\nNapięcie pomiarowe do 100 V od 0,1 MΩ do 0,5 MΩ CMC 0,05 % + 10 Ω\nNapięcie pomiarowe do 100 V od 0,6 MΩ do 0,9 MΩ CMC 0,05 % + 15 Ω\nNapięcie pomiarowe do 500 V od 1 MΩ do 5 MΩ CMC 0,05 % + 0,25 kΩ\nNapięcie pomiarowe do 500 V od 6 MΩ do 9 MΩ CMC 0,05 % + 0,35 kΩ\nNapięcie pomiarowe do 1000 V od 10 MΩ do 50 MΩ CMC 0,1 % + 2,5 kΩ\nNapięcie pomiarowe do 1000 V od 50 MΩ do 100 MΩ CMC 0,1 % + 9,0 kΩ\nNapięcie pomiarowe do 5000 V od 100 MΩ do 1000 MΩ CMC 1,2 %\nNapięcie pomiarowe do 5000 V od 1 GΩ do 10 GΩ CMC 1,2 %\nBezpośredni pomiar wzorcowej dekady rezystancyjnej","reference":"Kp 04-003","norm_bases":["Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja izolacji / Przyrządy do badań instalacji Wzorcowanie – wielkości elektryczne Bezpośredni pomiar wzorcowej dekady rezystancyjnej Napięcie pomiarowe do 100 V od 10 kΩ do 100 kΩ CMC 0,05 % + 14 Ω Napięcie pomiarowe do 100 V od 0,1 MΩ do 0,5 MΩ CMC 0,05 % + 10 Ω Napięcie pomiarowe do 100 V od 0,6 MΩ do 0,9 MΩ CMC 0,05 % + 15 Ω Napięcie pomiarowe do 500 V od 1 MΩ do 5 MΩ CMC 0,05 % + 0,25 kΩ Napięcie pomiarowe do 500 V od 6 MΩ do 9 MΩ CMC 0,05 % + 0,35 kΩ Napięcie pomiarowe do 1000 V od 10 MΩ do 50 MΩ CMC 0,1 % + 2,5 kΩ Napięcie pomiarowe do 1000 V od 50 MΩ do 100 MΩ CMC 0,1 % + 9,0 kΩ Napięcie pomiarowe do 5000 V od 100 MΩ do 1000 MΩ CMC 1,2 % Napięcie pomiarowe do 5000 V od 1 GΩ do 10 GΩ CMC 1,2 % Izolační odpor / Revizní přístroje Kalibrace – elektrické veličiny Přímé měření etalonové odporové dekády Měřící napětí do 100 V 10 kΩ až 100 kΩ CMC 0,05 % + 14 Ω Měřící napětí do 100 V 0,1 MΩ až 0,5 MΩ CMC 0,05 % + 10 Ω Měřící napětí do 100 V 0,6 MΩ až 0,9 MΩ CMC 0,05 % + 15 Ω Měřící napětí do 500 V 1 MΩ až 5 MΩ CMC 0,05 % + 0,25 kΩ Měřící napětí do 500 V 6 MΩ až 9 MΩ CMC 0,05 % + 0,35 kΩ Měřící napětí do 1000 V 10 MΩ až 50 MΩ CMC 0,1 % + 2,5 kΩ Měřící napětí do 1000 V 50 MΩ až 100 MΩ CMC 0,1 % + 9,0 kΩ Měřící napětí do 5000 V 100 MΩ až 1000 MΩ CMC 1,2 % Měřící napětí do 5000 V 1 GΩ až 10 GΩ CMC 1,2 % Kp 04-003 Rezystancja izolacji / Przyrzady do badan instalacji Wzorcowanie – wielkosci elektryczne Bezposredni pomiar wzorcowej dekady rezystancyjnej Napiecie pomiarowe do 100 V od 10 kΩ do 100 kΩ CMC 0,05 % + 14 Ω Napiecie pomiarowe do 100 V od 0,1 MΩ do 0,5 MΩ CMC 0,05 % + 10 Ω Napiecie pomiarowe do 100 V od 0,6 MΩ do 0,9 MΩ CMC 0,05 % + 15 Ω Napiecie pomiarowe do 500 V od 1 MΩ do 5 MΩ CMC 0,05 % + 0,25 kΩ Napiecie pomiarowe do 500 V od 6 MΩ do 9 MΩ CMC 0,05 % + 0,35 kΩ Napiecie pomiarowe do 1000 V od 10 MΩ do 50 MΩ CMC 0,1 % + 2,5 kΩ Napiecie pomiarowe do 1000 V od 50 MΩ do 100 MΩ CMC 0,1 % + 9,0 kΩ Napiecie pomiarowe do 5000 V od 100 MΩ do 1000 MΩ CMC 1,2 % Napiecie pomiarowe do 5000 V od 1 GΩ do 10 GΩ CMC 1,2 % Izolacni odpor / Revizni pristroje Kalibrace – elektricke veliciny Prime mereni etalonove odporove dekady Merici napeti do 100 V 10 kΩ az 100 kΩ CMC 0,05 % + 14 Ω Merici napeti do 100 V 0,1 MΩ az 0,5 MΩ CMC 0,05 % + 10 Ω Merici napeti do 100 V 0,6 MΩ az 0,9 MΩ CMC 0,05 % + 15 Ω Merici napeti do 500 V 1 MΩ az 5 MΩ CMC 0,05 % + 0,25 kΩ Merici napeti do 500 V 6 MΩ az 9 MΩ CMC 0,05 % + 0,35 kΩ Merici napeti do 1000 V 10 MΩ az 50 MΩ CMC 0,1 % + 2,5 kΩ Merici napeti do 1000 V 50 MΩ az 100 MΩ CMC 0,1 % + 9,0 kΩ Merici napeti do 5000 V 100 MΩ az 1000 MΩ CMC 1,2 % Merici napeti do 5000 V 1 GΩ az 10 GΩ CMC 1,2 % Kp 04-003","search_en":"Insulation resistance / Inspection instruments Calibration – electrical quantities Direct measurement of a reference resistance box Measuring voltage up to 100 V 10 kΩ to 100 kΩ CMC 0,05 % + 14 Ω Measuring voltage up to 100 V 0,1 MΩ to 0,5 MΩ CMC 0,05 % + 10 Ω Measuring voltage up to 100 V 0,6 MΩ to 0,9 MΩ CMC 0,05 % + 15 Ω Measuring voltage up to 500 V 1 MΩ to 5 MΩ CMC 0,05 % + 0,25 kΩ Measuring voltage up to 500 V 6 MΩ to 9 MΩ CMC 0,05 % + 0,35 kΩ Measuring voltage up to 1,000 V 10 MΩ to 50 MΩ CMC 0,1 % + 2,5 kΩ Measuring voltage up to 1,000 V 50 MΩ to 100 MΩ CMC 0,1 % + 9,0 kΩ Measuring voltage up to 5,000 V 100 MΩ to 1000 MΩ CMC 1,2 % Measuring voltage up to 5,000 V 1 GΩ to 10 GΩ CMC 1,2 % Kp 04-003","search_zh":"绝缘电阻 / 检验仪器 校准 – 电学量 直接测量标准电阻箱 测量电压不超过 100 V 10 kΩ 至 100 kΩ CMC 0,05 % + 14 Ω 测量电压不超过 100 V 0,1 MΩ 至 0,5 MΩ CMC 0,05 % + 10 Ω 测量电压不超过 100 V 0,6 MΩ 至 0,9 MΩ CMC 0,05 % + 15 Ω 测量电压不超过 500 V 1 MΩ 至 5 MΩ CMC 0,05 % + 0,25 kΩ 测量电压不超过 500 V 6 MΩ 至 9 MΩ CMC 0,05 % + 0,35 kΩ 测量电压不超过 1000 V 10 MΩ 至 50 MΩ CMC 0,1 % + 2,5 kΩ 测量电压不超过 1000 V 50 MΩ 至 100 MΩ CMC 0,1 % + 9,0 kΩ 测量电压不超过 5000 V 100 MΩ 至 1000 MΩ CMC 1,2 % 测量电压不超过 5000 V 1 GΩ 至 10 GΩ CMC 1,2 % Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":89,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"93df6fdd6f811a1d790d76fb","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"8","test_object":"Prąd upływu / Przyrządy do badań instalacji","test_object_en":"Leakage current / Inspection instruments","test_object_zh":"泄漏电流 / 检验仪器","test_object_cs":"Unikající proud / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz do 60 Hz","range":"od 0,1 mA do 1 mA","cmc":"0,10 % + 0,54 µA"},{"name":"50 Hz do 60 Hz","range":"od 1 mA do 10 mA","cmc":"0,15 % + 7,5 µA"},{"name":"50 Hz do 60 Hz","range":"od 10 mA do 100 mA","cmc":"0,10 % + 56 µA"}],"parameters_en":[{"name":"50 Hz to 60 Hz","range":"0,1 mA to 1 mA","cmc":"0,10 % + 0,54 µA"},{"name":"50 Hz to 60 Hz","range":"1 mA to 10 mA","cmc":"0,15 % + 7,5 µA"},{"name":"50 Hz to 60 Hz","range":"10 mA to 100 mA","cmc":"0,10 % + 56 µA"}],"parameters_zh":[{"name":"50 Hz 至 60 Hz","range":"0,1 mA 至 1 mA","cmc":"0,10 % + 0,54 µA"},{"name":"50 Hz 至 60 Hz","range":"1 mA 至 10 mA","cmc":"0,15 % + 7,5 µA"},{"name":"50 Hz 至 60 Hz","range":"10 mA 至 100 mA","cmc":"0,10 % + 56 µA"}],"parameters_cs":[{"name":"50 Hz až 60 Hz","range":"0,1 mA až 1 mA","cmc":"0,10 % + 0,54 µA"},{"name":"50 Hz až 60 Hz","range":"1 mA až 10 mA","cmc":"0,15 % + 7,5 µA"},{"name":"50 Hz až 60 Hz","range":"10 mA až 100 mA","cmc":"0,10 % + 56 µA"}],"technique":"Bezpośredni pomiar amperomierzem wzorcowym","technique_en":"Direct measurement by a reference ammeter","technique_zh":"用标准电流表直接测量","technique_cs":"Přímé měření etalonovým ampérmetrem","techniques":["Bezpośredni pomiar amperomierzem wzorcowym"],"techniques_en":["Direct measurement by a reference ammeter"],"techniques_zh":["用标准电流表直接测量"],"techniques_cs":["Přímé měření etalonovým ampérmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz do 60 Hz od 0,1 mA do 1 mA CMC 0,10 % + 0,54 µA\n50 Hz do 60 Hz od 1 mA do 10 mA CMC 0,15 % + 7,5 µA\n50 Hz do 60 Hz od 10 mA do 100 mA CMC 0,10 % + 56 µA\nBezpośredni pomiar amperomierzem wzorcowym","reference":"Kp 04-003","norm_bases":["Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd upływu / Przyrządy do badań instalacji Wzorcowanie – wielkości elektryczne Bezpośredni pomiar amperomierzem wzorcowym 50 Hz do 60 Hz od 0,1 mA do 1 mA CMC 0,10 % + 0,54 µA 50 Hz do 60 Hz od 1 mA do 10 mA CMC 0,15 % + 7,5 µA 50 Hz do 60 Hz od 10 mA do 100 mA CMC 0,10 % + 56 µA Unikající proud / Revizní přístroje Kalibrace – elektrické veličiny Přímé měření etalonovým ampérmetrem 50 Hz až 60 Hz 0,1 mA až 1 mA CMC 0,10 % + 0,54 µA 50 Hz až 60 Hz 1 mA až 10 mA CMC 0,15 % + 7,5 µA 50 Hz až 60 Hz 10 mA až 100 mA CMC 0,10 % + 56 µA Kp 04-003 Prad uplywu / Przyrzady do badan instalacji Wzorcowanie – wielkosci elektryczne Bezposredni pomiar amperomierzem wzorcowym 50 Hz do 60 Hz od 0,1 mA do 1 mA CMC 0,10 % + 0,54 µA 50 Hz do 60 Hz od 1 mA do 10 mA CMC 0,15 % + 7,5 µA 50 Hz do 60 Hz od 10 mA do 100 mA CMC 0,10 % + 56 µA Unikajici proud / Revizni pristroje Kalibrace – elektricke veliciny Prime mereni etalonovym ampermetrem 50 Hz az 60 Hz 0,1 mA az 1 mA CMC 0,10 % + 0,54 µA 50 Hz az 60 Hz 1 mA az 10 mA CMC 0,15 % + 7,5 µA 50 Hz az 60 Hz 10 mA az 100 mA CMC 0,10 % + 56 µA Kp 04-003","search_en":"Leakage current / Inspection instruments Calibration – electrical quantities Direct measurement by a reference ammeter 50 Hz to 60 Hz 0,1 mA to 1 mA CMC 0,10 % + 0,54 µA 50 Hz to 60 Hz 1 mA to 10 mA CMC 0,15 % + 7,5 µA 50 Hz to 60 Hz 10 mA to 100 mA CMC 0,10 % + 56 µA Kp 04-003","search_zh":"泄漏电流 / 检验仪器 校准 – 电学量 用标准电流表直接测量 50 Hz 至 60 Hz 0,1 mA 至 1 mA CMC 0,10 % + 0,54 µA 50 Hz 至 60 Hz 1 mA 至 10 mA CMC 0,15 % + 7,5 µA 50 Hz 至 60 Hz 10 mA 至 100 mA CMC 0,10 % + 56 µA Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":90,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dee1ca55892a02a0e4f00b01","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"9","test_object":"Impedancja pętli ochronnej, impedancja sieci / Przyrządy do badań instalacji","test_object_en":"Impedance of a protective loop, mains impedance / Inspection instruments","test_object_zh":"保护回路阻抗、电网阻抗 / 检验仪器","test_object_cs":"Impedance ochranné smyčky, impedance sítě / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"Wartość parametru Z₀","range":"od 0,4 Ω do 2 Ω","cmc":"32 mΩ"},{"name":"","range":"od 0,05 Ω do + Z₀","cmc":"5,1 mΩ"},{"name":"","range":"od 0,10 Ω do + Z₀","cmc":"5,5 mΩ"},{"name":"","range":"od 0,22 Ω do + Z₀","cmc":"6,1 mΩ"},{"name":"","range":"od 0,33 Ω do + Z₀","cmc":"6,8 mΩ"},{"name":"","range":"od 0,50 Ω do + Z₀","cmc":"7,6 mΩ"},{"name":"","range":"od 1,0 Ω do + Z₀","cmc":"11 mΩ"},{"name":"","range":"od 5,0 Ω do + Z₀","cmc":"34 mΩ"},{"name":"","range":"od 10 Ω do + Z₀","cmc":"57 mΩ"},{"name":"","range":"od 100 Ω do + Z₀","cmc":"0,53 Ω"},{"name":"","range":"od 1000 Ω do + Z₀","cmc":"5,2 Ω"}],"parameters_en":[{"name":"Z₀ parameter value","range":"0,4 Ω to 2 Ω","cmc":"32 mΩ"},{"name":"","range":"0,05 Ω to + Z₀","cmc":"5,1 mΩ"},{"name":"","range":"0,10 Ω to + Z₀","cmc":"5,5 mΩ"},{"name":"","range":"0,22 Ω to + Z₀","cmc":"6,1 mΩ"},{"name":"","range":"0,33 Ω to + Z₀","cmc":"6,8 mΩ"},{"name":"","range":"0,50 Ω to + Z₀","cmc":"7,6 mΩ"},{"name":"","range":"1,0 Ω to + Z₀","cmc":"11 mΩ"},{"name":"","range":"5,0 Ω to + Z₀","cmc":"34 mΩ"},{"name":"","range":"10 Ω to + Z₀","cmc":"57 mΩ"},{"name":"","range":"100 Ω to + Z₀","cmc":"0,53 Ω"},{"name":"","range":"1000 Ω to + Z₀","cmc":"5,2 Ω"}],"parameters_zh":[{"name":"Z₀ 参数值","range":"0,4 Ω 至 2 Ω","cmc":"32 mΩ"},{"name":"","range":"0,05 Ω 至 + Z₀","cmc":"5,1 mΩ"},{"name":"","range":"0,10 Ω 至 + Z₀","cmc":"5,5 mΩ"},{"name":"","range":"0,22 Ω 至 + Z₀","cmc":"6,1 mΩ"},{"name":"","range":"0,33 Ω 至 + Z₀","cmc":"6,8 mΩ"},{"name":"","range":"0,50 Ω 至 + Z₀","cmc":"7,6 mΩ"},{"name":"","range":"1,0 Ω 至 + Z₀","cmc":"11 mΩ"},{"name":"","range":"5,0 Ω 至 + Z₀","cmc":"34 mΩ"},{"name":"","range":"10 Ω 至 + Z₀","cmc":"57 mΩ"},{"name":"","range":"100 Ω 至 + Z₀","cmc":"0,53 Ω"},{"name":"","range":"1000 Ω 至 + Z₀","cmc":"5,2 Ω"}],"parameters_cs":[{"name":"Hodnota parametru Z₀","range":"0,4 Ω až 2 Ω","cmc":"32 mΩ"},{"name":"","range":"0,05 Ω až + Z₀","cmc":"5,1 mΩ"},{"name":"","range":"0,10 Ω až + Z₀","cmc":"5,5 mΩ"},{"name":"","range":"0,22 Ω až + Z₀","cmc":"6,1 mΩ"},{"name":"","range":"0,33 Ω až + Z₀","cmc":"6,8 mΩ"},{"name":"","range":"0,50 Ω až + Z₀","cmc":"7,6 mΩ"},{"name":"","range":"1,0 Ω až + Z₀","cmc":"11 mΩ"},{"name":"","range":"5,0 Ω až + Z₀","cmc":"34 mΩ"},{"name":"","range":"10 Ω až + Z₀","cmc":"57 mΩ"},{"name":"","range":"100 Ω až + Z₀","cmc":"0,53 Ω"},{"name":"","range":"1000 Ω až + Z₀","cmc":"5,2 Ω"}],"technique":"Bezpośrednie generowanie impedancji kalibratorem wzorcowym","technique_en":"Direct generation of impedance with a reference calibrator","technique_zh":"用标准校准器直接产生阻抗","technique_cs":"Přímé generování impedance etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie impedancji kalibratorem wzorcowym"],"techniques_en":["Direct generation of impedance with a reference calibrator"],"techniques_zh":["用标准校准器直接产生阻抗"],"techniques_cs":["Přímé generování impedance etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nWartość parametru Z₀ od 0,4 Ω do 2 Ω CMC 32 mΩ\nod 0,05 Ω do + Z₀ CMC 5,1 mΩ\nod 0,10 Ω do + Z₀ CMC 5,5 mΩ\nod 0,22 Ω do + Z₀ CMC 6,1 mΩ\nod 0,33 Ω do + Z₀ CMC 6,8 mΩ\nod 0,50 Ω do + Z₀ CMC 7,6 mΩ\nod 1,0 Ω do + Z₀ CMC 11 mΩ\nod 5,0 Ω do + Z₀ CMC 34 mΩ\nod 10 Ω do + Z₀ CMC 57 mΩ\nod 100 Ω do + Z₀ CMC 0,53 Ω\nod 1000 Ω do + Z₀ CMC 5,2 Ω\nBezpośrednie generowanie impedancji kalibratorem wzorcowym","reference":"Kp 04-003","norm_bases":["Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Impedancja pętli ochronnej, impedancja sieci / Przyrządy do badań instalacji Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie impedancji kalibratorem wzorcowym Wartość parametru Z₀ od 0,4 Ω do 2 Ω CMC 32 mΩ od 0,05 Ω do + Z₀ CMC 5,1 mΩ od 0,10 Ω do + Z₀ CMC 5,5 mΩ od 0,22 Ω do + Z₀ CMC 6,1 mΩ od 0,33 Ω do + Z₀ CMC 6,8 mΩ od 0,50 Ω do + Z₀ CMC 7,6 mΩ od 1,0 Ω do + Z₀ CMC 11 mΩ od 5,0 Ω do + Z₀ CMC 34 mΩ od 10 Ω do + Z₀ CMC 57 mΩ od 100 Ω do + Z₀ CMC 0,53 Ω od 1000 Ω do + Z₀ CMC 5,2 Ω Impedance ochranné smyčky, impedance sítě / Revizní přístroje Kalibrace – elektrické veličiny Přímé generování impedance etalonovým kalibrátorem Hodnota parametru Z₀ 0,4 Ω až 2 Ω CMC 32 mΩ 0,05 Ω až + Z₀ CMC 5,1 mΩ 0,10 Ω až + Z₀ CMC 5,5 mΩ 0,22 Ω až + Z₀ CMC 6,1 mΩ 0,33 Ω až + Z₀ CMC 6,8 mΩ 0,50 Ω až + Z₀ CMC 7,6 mΩ 1,0 Ω až + Z₀ CMC 11 mΩ 5,0 Ω až + Z₀ CMC 34 mΩ 10 Ω až + Z₀ CMC 57 mΩ 100 Ω až + Z₀ CMC 0,53 Ω 1000 Ω až + Z₀ CMC 5,2 Ω Kp 04-003 Impedancja petli ochronnej, impedancja sieci / Przyrzady do badan instalacji Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie impedancji kalibratorem wzorcowym Wartosc parametru Z₀ od 0,4 Ω do 2 Ω CMC 32 mΩ od 0,05 Ω do + Z₀ CMC 5,1 mΩ od 0,10 Ω do + Z₀ CMC 5,5 mΩ od 0,22 Ω do + Z₀ CMC 6,1 mΩ od 0,33 Ω do + Z₀ CMC 6,8 mΩ od 0,50 Ω do + Z₀ CMC 7,6 mΩ od 1,0 Ω do + Z₀ CMC 11 mΩ od 5,0 Ω do + Z₀ CMC 34 mΩ od 10 Ω do + Z₀ CMC 57 mΩ od 100 Ω do + Z₀ CMC 0,53 Ω od 1000 Ω do + Z₀ CMC 5,2 Ω Impedance ochranne smycky, impedance site / Revizni pristroje Kalibrace – elektricke veliciny Prime generovani impedance etalonovym kalibratorem Hodnota parametru Z₀ 0,4 Ω az 2 Ω CMC 32 mΩ 0,05 Ω az + Z₀ CMC 5,1 mΩ 0,10 Ω az + Z₀ CMC 5,5 mΩ 0,22 Ω az + Z₀ CMC 6,1 mΩ 0,33 Ω az + Z₀ CMC 6,8 mΩ 0,50 Ω az + Z₀ CMC 7,6 mΩ 1,0 Ω az + Z₀ CMC 11 mΩ 5,0 Ω az + Z₀ CMC 34 mΩ 10 Ω az + Z₀ CMC 57 mΩ 100 Ω az + Z₀ CMC 0,53 Ω 1000 Ω az + Z₀ CMC 5,2 Ω Kp 04-003","search_en":"Impedance of a protective loop, mains impedance / Inspection instruments Calibration – electrical quantities Direct generation of impedance with a reference calibrator Z₀ parameter value 0,4 Ω to 2 Ω CMC 32 mΩ 0,05 Ω to + Z₀ CMC 5,1 mΩ 0,10 Ω to + Z₀ CMC 5,5 mΩ 0,22 Ω to + Z₀ CMC 6,1 mΩ 0,33 Ω to + Z₀ CMC 6,8 mΩ 0,50 Ω to + Z₀ CMC 7,6 mΩ 1,0 Ω to + Z₀ CMC 11 mΩ 5,0 Ω to + Z₀ CMC 34 mΩ 10 Ω to + Z₀ CMC 57 mΩ 100 Ω to + Z₀ CMC 0,53 Ω 1000 Ω to + Z₀ CMC 5,2 Ω Kp 04-003","search_zh":"保护回路阻抗、电网阻抗 / 检验仪器 校准 – 电学量 用标准校准器直接产生阻抗 Z₀ 参数值 0,4 Ω 至 2 Ω CMC 32 mΩ 0,05 Ω 至 + Z₀ CMC 5,1 mΩ 0,10 Ω 至 + Z₀ CMC 5,5 mΩ 0,22 Ω 至 + Z₀ CMC 6,1 mΩ 0,33 Ω 至 + Z₀ CMC 6,8 mΩ 0,50 Ω 至 + Z₀ CMC 7,6 mΩ 1,0 Ω 至 + Z₀ CMC 11 mΩ 5,0 Ω 至 + Z₀ CMC 34 mΩ 10 Ω 至 + Z₀ CMC 57 mΩ 100 Ω 至 + Z₀ CMC 0,53 Ω 1000 Ω 至 + Z₀ CMC 5,2 Ω Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":91,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"52829c73bee7e463eaaa0d78","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"10","test_object":"Prąd zadziałania wyłączników różnicowoprądowych / Przyrządy do badań instalacji","test_object_en":"Tripping current of residual current circuit breakers / Inspection instruments","test_object_zh":"剩余电流保护器动作电流 / 检验仪器","test_object_cs":"Vybavovací proud proudových chráničů / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 2 mA do 10 mA","cmc":"1,2 % + 72 µA"},{"name":"","range":"od 10 mA do 30 mA","cmc":"1,2 % + 0,11 mA"},{"name":"","range":"od 30 mA do 100 mA","cmc":"1,2 % + 0,17 mA"},{"name":"","range":"od 100 mA do 300 mA","cmc":"1,2 % + 0,84 mA"},{"name":"","range":"od 300 mA do 1000 mA","cmc":"1,2 % + 1,7 mA"},{"name":"","range":"od 1000 mA do 3000 mA","cmc":"1,2 % + 3,0 mA"}],"parameters_en":[{"name":"","range":"2 mA to 10 mA","cmc":"1,2 % + 72 µA"},{"name":"","range":"10 mA to 30 mA","cmc":"1,2 % + 0,11 mA"},{"name":"","range":"30 mA to 100 mA","cmc":"1,2 % + 0,17 mA"},{"name":"","range":"100 mA to 300 mA","cmc":"1,2 % + 0,84 mA"},{"name":"","range":"300 mA to 1000 mA","cmc":"1,2 % + 1,7 mA"},{"name":"","range":"1000 mA to 3000 mA","cmc":"1,2 % + 3,0 mA"}],"parameters_zh":[{"name":"","range":"2 mA 至 10 mA","cmc":"1,2 % + 72 µA"},{"name":"","range":"10 mA 至 30 mA","cmc":"1,2 % + 0,11 mA"},{"name":"","range":"30 mA 至 100 mA","cmc":"1,2 % + 0,17 mA"},{"name":"","range":"100 mA 至 300 mA","cmc":"1,2 % + 0,84 mA"},{"name":"","range":"300 mA 至 1000 mA","cmc":"1,2 % + 1,7 mA"},{"name":"","range":"1000 mA 至 3000 mA","cmc":"1,2 % + 3,0 mA"}],"parameters_cs":[{"name":"","range":"2 mA až 10 mA","cmc":"1,2 % + 72 µA"},{"name":"","range":"10 mA až 30 mA","cmc":"1,2 % + 0,11 mA"},{"name":"","range":"30 mA až 100 mA","cmc":"1,2 % + 0,17 mA"},{"name":"","range":"100 mA až 300 mA","cmc":"1,2 % + 0,84 mA"},{"name":"","range":"300 mA až 1000 mA","cmc":"1,2 % + 1,7 mA"},{"name":"","range":"1000 mA až 3000 mA","cmc":"1,2 % + 3,0 mA"}],"technique":"Porównanie z kalibratorem wzorcowym","technique_en":"Comparison with a reference calibrator","technique_zh":"与标准校准器比较","technique_cs":"Porovnání s etalonovým kalibrátorem","techniques":["Porównanie z kalibratorem wzorcowym"],"techniques_en":["Comparison with a reference calibrator"],"techniques_zh":["与标准校准器比较"],"techniques_cs":["Porovnání s etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 2 mA do 10 mA CMC 1,2 % + 72 µA\nod 10 mA do 30 mA CMC 1,2 % + 0,11 mA\nod 30 mA do 100 mA CMC 1,2 % + 0,17 mA\nod 100 mA do 300 mA CMC 1,2 % + 0,84 mA\nod 300 mA do 1000 mA CMC 1,2 % + 1,7 mA\nod 1000 mA do 3000 mA CMC 1,2 % + 3,0 mA\nPorównanie z kalibratorem wzorcowym","reference":"Kp 04-003","norm_bases":["Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd zadziałania wyłączników różnicowoprądowych / Przyrządy do badań instalacji Wzorcowanie – wielkości elektryczne Porównanie z kalibratorem wzorcowym od 2 mA do 10 mA CMC 1,2 % + 72 µA od 10 mA do 30 mA CMC 1,2 % + 0,11 mA od 30 mA do 100 mA CMC 1,2 % + 0,17 mA od 100 mA do 300 mA CMC 1,2 % + 0,84 mA od 300 mA do 1000 mA CMC 1,2 % + 1,7 mA od 1000 mA do 3000 mA CMC 1,2 % + 3,0 mA Vybavovací proud proudových chráničů / Revizní přístroje Kalibrace – elektrické veličiny Porovnání s etalonovým kalibrátorem 2 mA až 10 mA CMC 1,2 % + 72 µA 10 mA až 30 mA CMC 1,2 % + 0,11 mA 30 mA až 100 mA CMC 1,2 % + 0,17 mA 100 mA až 300 mA CMC 1,2 % + 0,84 mA 300 mA až 1000 mA CMC 1,2 % + 1,7 mA 1000 mA až 3000 mA CMC 1,2 % + 3,0 mA Kp 04-003 Prad zadzialania wylacznikow roznicowopradowych / Przyrzady do badan instalacji Wzorcowanie – wielkosci elektryczne Porownanie z kalibratorem wzorcowym od 2 mA do 10 mA CMC 1,2 % + 72 µA od 10 mA do 30 mA CMC 1,2 % + 0,11 mA od 30 mA do 100 mA CMC 1,2 % + 0,17 mA od 100 mA do 300 mA CMC 1,2 % + 0,84 mA od 300 mA do 1000 mA CMC 1,2 % + 1,7 mA od 1000 mA do 3000 mA CMC 1,2 % + 3,0 mA Vybavovaci proud proudovych chranicu / Revizni pristroje Kalibrace – elektricke veliciny Porovnani s etalonovym kalibratorem 2 mA az 10 mA CMC 1,2 % + 72 µA 10 mA az 30 mA CMC 1,2 % + 0,11 mA 30 mA az 100 mA CMC 1,2 % + 0,17 mA 100 mA az 300 mA CMC 1,2 % + 0,84 mA 300 mA az 1000 mA CMC 1,2 % + 1,7 mA 1000 mA az 3000 mA CMC 1,2 % + 3,0 mA Kp 04-003","search_en":"Tripping current of residual current circuit breakers / Inspection instruments Calibration – electrical quantities Comparison with a reference calibrator 2 mA to 10 mA CMC 1,2 % + 72 µA 10 mA to 30 mA CMC 1,2 % + 0,11 mA 30 mA to 100 mA CMC 1,2 % + 0,17 mA 100 mA to 300 mA CMC 1,2 % + 0,84 mA 300 mA to 1000 mA CMC 1,2 % + 1,7 mA 1000 mA to 3000 mA CMC 1,2 % + 3,0 mA Kp 04-003","search_zh":"剩余电流保护器动作电流 / 检验仪器 校准 – 电学量 与标准校准器比较 2 mA 至 10 mA CMC 1,2 % + 72 µA 10 mA 至 30 mA CMC 1,2 % + 0,11 mA 30 mA 至 100 mA CMC 1,2 % + 0,17 mA 100 mA 至 300 mA CMC 1,2 % + 0,84 mA 300 mA 至 1000 mA CMC 1,2 % + 1,7 mA 1000 mA 至 3000 mA CMC 1,2 % + 3,0 mA Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":92,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7bd9e1f51be513c38a3e0074","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"11","test_object":"Czas wyłączania wyłączników różnicowoprądowych / Przyrządy do badań instalacji","test_object_en":"Tripping time of residual current circuit breakers / Inspection instruments","test_object_zh":"剩余电流保护器分断时间 / 检验仪器","test_object_cs":"Vypínací čas proudových chráničů / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 20 ms do 900 ms","cmc":"1 ms"}],"parameters_en":[{"name":"","range":"20 ms to 900 ms","cmc":"1 ms"}],"parameters_zh":[{"name":"","range":"20 ms 至 900 ms","cmc":"1 ms"}],"parameters_cs":[{"name":"","range":"20 ms až 900 ms","cmc":"1 ms"}],"technique":"Porównanie z kalibratorem wzorcowym","technique_en":"Comparison with a reference calibrator","technique_zh":"与标准校准器比较","technique_cs":"Porovnání s etalonovým kalibrátorem","techniques":["Porównanie z kalibratorem wzorcowym"],"techniques_en":["Comparison with a reference calibrator"],"techniques_zh":["与标准校准器比较"],"techniques_cs":["Porovnání s etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 20 ms do 900 ms CMC 1 ms\nPorównanie z kalibratorem wzorcowym","reference":"Kp 04-003","norm_bases":["Kp 04-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czas wyłączania wyłączników różnicowoprądowych / Przyrządy do badań instalacji Wzorcowanie – wielkości elektryczne Porównanie z kalibratorem wzorcowym od 20 ms do 900 ms CMC 1 ms Vypínací čas proudových chráničů / Revizní přístroje Kalibrace – elektrické veličiny Porovnání s etalonovým kalibrátorem 20 ms až 900 ms CMC 1 ms Kp 04-003 Czas wylaczania wylacznikow roznicowopradowych / Przyrzady do badan instalacji Wzorcowanie – wielkosci elektryczne Porownanie z kalibratorem wzorcowym od 20 ms do 900 ms CMC 1 ms Vypinaci cas proudovych chranicu / Revizni pristroje Kalibrace – elektricke veliciny Porovnani s etalonovym kalibratorem 20 ms az 900 ms CMC 1 ms Kp 04-003","search_en":"Tripping time of residual current circuit breakers / Inspection instruments Calibration – electrical quantities Comparison with a reference calibrator 20 ms to 900 ms CMC 1 ms Kp 04-003","search_zh":"剩余电流保护器分断时间 / 检验仪器 校准 – 电学量 与标准校准器比较 20 ms 至 900 ms CMC 1 ms Kp 04-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":93,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"862870ee1d1cf593779d7069","lab_id":"6ade8b40ff06824761708128","country":"CZ","accr_number":"2374","accr_body":"ČIA","row_label":"1","test_object":"Przedział czasu / stopery mechaniczne i cyfrowe, timery i inne przyrządy do pomiaru czasu","test_object_en":"Time interval / mechanical and digital stopwatch, timers and other time meters","test_object_zh":"时间间隔 / 机械和数字秒表、定时器及其他计时器具","test_object_cs":"Časový interval / mechanické a digitální stopky, časovače a jiná měřidla času","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 5 s do 3600 s","cmc":"11 ms"}],"parameters_en":[{"name":"","range":"5 s to 3600 s","cmc":"11 ms"}],"parameters_zh":[{"name":"","range":"5 s 至 3600 s","cmc":"11 ms"}],"parameters_cs":[{"name":"","range":"5 s až 3600 s","cmc":"11 ms"}],"technique":"Porównanie z licznikiem wzorcowym","technique_en":"Comparison with a reference counter","technique_zh":"与标准计数器比较","technique_cs":"Porovnání s etalonovým čítačem","techniques":["Porównanie z licznikiem wzorcowym"],"techniques_en":["Comparison with a reference counter"],"techniques_zh":["与标准计数器比较"],"techniques_cs":["Porovnání s etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 5 s do 3600 s CMC 11 ms\nPorównanie z licznikiem wzorcowym","reference":"Kp 06-001","norm_bases":["Kp 06-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / stopery mechaniczne i cyfrowe, timery i inne przyrządy do pomiaru czasu Wzorcowanie – wielkości czasu i częstotliwości Porównanie z licznikiem wzorcowym od 5 s do 3600 s CMC 11 ms Časový interval / mechanické a digitální stopky, časovače a jiná měřidla času Kalibrace – veličiny času a frekvence Porovnání s etalonovým čítačem 5 s až 3600 s CMC 11 ms Kp 06-001 Przedzial czasu / stopery mechaniczne i cyfrowe, timery i inne przyrzady do pomiaru czasu Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie z licznikiem wzorcowym od 5 s do 3600 s CMC 11 ms Casovy interval / mechanicke a digitalni stopky, casovace a jina meridla casu Kalibrace – veliciny casu a frekvence Porovnani s etalonovym citacem 5 s az 3600 s CMC 11 ms Kp 06-001","search_en":"Time interval / mechanical and digital stopwatch, timers and other time meters Calibration – time and frequency quantities Comparison with a reference counter 5 s to 3600 s CMC 11 ms Kp 06-001","search_zh":"时间间隔 / 机械和数字秒表、定时器及其他计时器具 校准 – 时间和频率量 与标准计数器比较 5 s 至 3600 s CMC 11 ms Kp 06-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":94,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}