🇨🇿 Scanlab Praha s.r.o. PL
Metrology & calibration
Scanlab Praha s.r.o. is a calibration laboratory accredited by ČIA under number 2373 (Praha 9, Czech Republic). Its accreditation scope covers 8 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electronic thermometers, Electronic hygrometers, Glass thermometers, Piston-operated volumetric instruments – dispensers. Most frequently used calibration principles: Direct comparison in a liquid bath, Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/…, Comparison of temperature values from the data logger with the reco….
At a glance
- Accreditation number: ČIA 2373
- Calibration items in scope: 8
- Types of calibrated items: 6
- Calibration principles used: 6
- City: Praha 9, Czech Republic
- Valid until: 06-10-2030
- Accreditation number
- 2373
- Accreditation body
- ČIA
- Address
- Dr. Marodyho 143/20, Čakovice, 196 00 Praha 9
- City
- Praha 9, Czech Republic
- Division
- Laboratorium wzorcujące Scanlab Praha
- Valid until
- 06-10-2030
What this laboratory calibrates (6)
- Electronic thermometers — 3 calibration items
- Electronic hygrometers — 1 calibration item
- Glass thermometers — 1 calibration item
- Piston-operated volumetric instruments – dispensers — 1 calibration item
- Piston-operated volumetric instruments – pipettes — 1 calibration item
- Temperature and temperature field homogeneity in refrigerators and freezers — 1 calibration item
Calibration principles (6)
- Direct comparison in a liquid bath — 2 calibration items
- Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/2018; ISO/TR 20461:2023-02) — 2 calibration items
- Comparison of temperature values from the data logger with the record of values from the temperature standard — 1 calibration item
- Comparison with a standard thermometer in the customer's thermostat — 1 calibration item
- Direct comparison in a dry-block furnace — 1 calibration item
- Direct comparison with a standard in a climatic chamber — 1 calibration item
Certificate information
- Certificate date
- 06.10.2025
Accreditation scope — calibration items (8)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Piston-operated volumetric instruments – pipettes | Calibration – volume 0,5 µl to 10000 µl · CMC 0,13 %+ 0,01µl CMC for the field of measured quantity: Volume |
Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/2018; ISO/TR 20461:2023-02) | SOP1 | |
| 2 | Piston-operated volumetric instruments – dispensers | Calibration – volume 0,01 ml to 100 ml · CMC 0,06 %+ 0,03µl CMC for the field of measured quantity: Volume |
Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/2018; ISO/TR 20461:2023-02) | SOP2 | |
| 3 | Electronic thermometers | Calibration – temperature -85 °C to -50 °C · CMC 0,60 °C -50 °C to 0 °C · CMC 0,30 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard thermometer in the customer's thermostat | SOP4 | |
| 4 | Electronic thermometers | Calibration – temperature -30 °C to 0 °C · CMC 0,20 °C 0 °C to 80 °C · CMC 0,13 °C CMC for the field of measured quantity: Temperature |
Direct comparison in a liquid bath | SOP4 | |
| 5 | Electronic thermometers | Calibration – temperature 80 °C to 100 °C · CMC 0,14 °C 100 °C to 130 °C · CMC 0,20 °C CMC for the field of measured quantity: Temperature |
Direct comparison in a dry-block furnace | SOP4 | |
| 6 | Glass thermometers | Calibration – temperature -30 °C to 80 °C · CMC 0,08 °C CMC for the field of measured quantity: Temperature |
Direct comparison in a liquid bath | SOP3 | |
| 7 | Temperature and temperature field homogeneity in refrigerators and freezers | Calibration – temperature -30 °C to 50 °C · CMC 0,60 °C CMC for the field of measured quantity: Temperature |
Comparison of temperature values from the data logger with the record of values from the temperature standard | SOP6 | |
| 8 | Electronic hygrometers | Calibration – air humidity 10 °C to 80 °C — 20 % RH to 80 % RH · CMC 2,8 % RH CMC for the field of measured quantity: Air humidity |
Direct comparison with a standard in a climatic chamber | SOP7 | |
Reference standards (6)
SOP1
SOP2
SOP3
SOP4
SOP6