{"lab":{"_id":"6ade8b3eff06824761708127","accr_number":"2373","country":"CZ","accr_body":"ČIA","address":"Dr. Marodyho 143/20, Čakovice, 196 00 Praha 9","categories":["metrology"],"city":"Praha 9","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.5223079,50.1503576]},"map_coord":[50.1503576,14.5223079],"map_geo":"cai-mapa","methods_count":8,"name":"Scanlab Praha s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: objętość, temperatura i wilgotność powietrza, w zakresie określonym w załączniku do świadectwa.","search_text":"scanlab praha s.r.o. dr. marodyho 143/20, čakovice, 196 00 praha 9 2373","source_page_url":"https://www.cai.cz/?subjekt=2373-scanlab-praha-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"06-10-2030","website":"www.scanlab.cz; www.kalibracepipet.cz; www.kalibracnilaborator.eu","certificate_date":"06.10.2025","certificate_no":"504/2025","certificate_replaces":"315/2023 z 15.06.2023","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: objętość, temperatura i wilgotność powietrza, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the fields of volume, temperature and air humidity, to the extent specified in the appendix to this Certificate.","zh":"体积、温度和空气湿度领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech objem, teplota a vlhkost vzduchu, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące Scanlab Praha","lab_division_cs":"Kalibrační laboratoř Scanlab Praha","lab_division_en":"Scanlab Praha Calibration Laboratory","lab_division_zh":"Scanlab Praha 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"c2e31f040af87ef9f73e6704505a6e345594d4db61447363e7a1f96ca62b74b3","source_pdf_url":"https://www.cai.cz/OA/pdf/504_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"2feb0c44926b8403ab75a9b8","lab_id":"6ade8b3eff06824761708127","country":"CZ","accr_number":"2373","accr_body":"ČIA","row_label":"1","test_object":"Tłokowe przyrządy do pomiaru objętości – pipety","test_object_en":"Piston-operated volumetric instruments – pipettes","test_object_zh":"活塞式容量器具 – 移液器","test_object_cs":"Pístová objemová měřidla – pipety","methodology":"Wzorcowanie – objętość","methodology_en":"Calibration – volume","methodology_zh":"校准 – 体积","methodology_cs":"Kalibrace – objem","parameters":[{"name":"","range":"od 0,5 µl do 10000 µl","cmc":"0,13 %+ 0,01µl"}],"parameters_en":[{"name":"","range":"0,5 µl to 10000 µl","cmc":"0,13 %+ 0,01µl"}],"parameters_zh":[{"name":"","range":"0,5 µl 至 10000 µl","cmc":"0,13 %+ 0,01µl"}],"parameters_cs":[{"name":"","range":"0,5 µl až 10000 µl","cmc":"0,13 %+ 0,01µl"}],"technique":"Grawimetrycznie (ČSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02)","technique_en":"Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/2018; ISO/TR 20461:2023-02)","technique_zh":"称量法（ČSN EN ISO 8655-6；EURAMET cg-19，3.0 版，09/2018；ISO/TR 20461:2023-02）","technique_cs":"Gravimetricky (ČSN EN ISO 8655-6; EURAMET cg-19, verze 3.0, 09/2018; ISO/TR 20461:2023-02)","techniques":["Grawimetrycznie (ČSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02)"],"techniques_en":["Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/2018; ISO/TR 20461:2023-02)"],"techniques_zh":["称量法（ČSN EN ISO 8655-6；EURAMET cg-19，3.0 版，09/2018；ISO/TR 20461:2023-02）"],"techniques_cs":["Gravimetricky (ČSN EN ISO 8655-6; EURAMET cg-19, verze 3.0, 09/2018; ISO/TR 20461:2023-02)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość\nod 0,5 µl do 10000 µl CMC 0,13 %+ 0,01µl\nGrawimetrycznie (ČSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02)","reference":"SOP1","norm_bases":["SOP1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość","regulatory_area_en":"CMC for the field of measured quantity: Volume","regulatory_area_zh":"被测量领域的CMC：体积","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłokowe przyrządy do pomiaru objętości – pipety Wzorcowanie – objętość Grawimetrycznie (ČSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02) od 0,5 µl do 10000 µl CMC 0,13 %+ 0,01µl Pístová objemová měřidla – pipety Kalibrace – objem Gravimetricky (ČSN EN ISO 8655-6; EURAMET cg-19, verze 3.0, 09/2018; ISO/TR 20461:2023-02) 0,5 µl až 10000 µl CMC 0,13 %+ 0,01µl SOP1 Tlokowe przyrzady do pomiaru objetosci – pipety Wzorcowanie – objetosc Grawimetrycznie (CSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02) od 0,5 µl do 10000 µl CMC 0,13 %+ 0,01µl Pistova objemova meridla – pipety Kalibrace – objem Gravimetricky (CSN EN ISO 8655-6; EURAMET cg-19, verze 3.0, 09/2018; ISO/TR 20461:2023-02) 0,5 µl az 10000 µl CMC 0,13 %+ 0,01µl SOP1","search_en":"Piston-operated volumetric instruments – pipettes Calibration – volume Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/2018; ISO/TR 20461:2023-02) 0,5 µl to 10000 µl CMC 0,13 %+ 0,01µl SOP1","search_zh":"活塞式容量器具 – 移液器 校准 – 体积 称量法（ČSN EN ISO 8655-6；EURAMET cg-19，3.0 版，09/2018；ISO/TR 20461:2023-02） 0,5 µl 至 10000 µl CMC 0,13 %+ 0,01µl SOP1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c97178634238b8aaa8148b62","lab_id":"6ade8b3eff06824761708127","country":"CZ","accr_number":"2373","accr_body":"ČIA","row_label":"2","test_object":"Tłokowe przyrządy do pomiaru objętości – dozowniki","test_object_en":"Piston-operated volumetric instruments – dispensers","test_object_zh":"活塞式容量器具 – 分液器","test_object_cs":"Pístová objemová měřidla – dávkovače","methodology":"Wzorcowanie – objętość","methodology_en":"Calibration – volume","methodology_zh":"校准 – 体积","methodology_cs":"Kalibrace – objem","parameters":[{"name":"","range":"od 0,01 ml do 100 ml","cmc":"0,06 %+ 0,03µl"}],"parameters_en":[{"name":"","range":"0,01 ml to 100 ml","cmc":"0,06 %+ 0,03µl"}],"parameters_zh":[{"name":"","range":"0,01 ml 至 100 ml","cmc":"0,06 %+ 0,03µl"}],"parameters_cs":[{"name":"","range":"0,01 ml až 100 ml","cmc":"0,06 %+ 0,03µl"}],"technique":"Grawimetrycznie (ČSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02)","technique_en":"Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/2018; ISO/TR 20461:2023-02)","technique_zh":"称量法（ČSN EN ISO 8655-6；EURAMET cg-19，3.0 版，09/2018；ISO/TR 20461:2023-02）","technique_cs":"Gravimetricky (ČSN EN ISO 8655-6; EURAMET cg-19, verze 3.0, 09/2018; ISO/TR 20461:2023-02)","techniques":["Grawimetrycznie (ČSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02)"],"techniques_en":["Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/2018; ISO/TR 20461:2023-02)"],"techniques_zh":["称量法（ČSN EN ISO 8655-6；EURAMET cg-19，3.0 版，09/2018；ISO/TR 20461:2023-02）"],"techniques_cs":["Gravimetricky (ČSN EN ISO 8655-6; EURAMET cg-19, verze 3.0, 09/2018; ISO/TR 20461:2023-02)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość\nod 0,01 ml do 100 ml CMC 0,06 %+ 0,03µl\nGrawimetrycznie (ČSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02)","reference":"SOP2","norm_bases":["SOP2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość","regulatory_area_en":"CMC for the field of measured quantity: Volume","regulatory_area_zh":"被测量领域的CMC：体积","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłokowe przyrządy do pomiaru objętości – dozowniki Wzorcowanie – objętość Grawimetrycznie (ČSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02) od 0,01 ml do 100 ml CMC 0,06 %+ 0,03µl Pístová objemová měřidla – dávkovače Kalibrace – objem Gravimetricky (ČSN EN ISO 8655-6; EURAMET cg-19, verze 3.0, 09/2018; ISO/TR 20461:2023-02) 0,01 ml až 100 ml CMC 0,06 %+ 0,03µl SOP2 Tlokowe przyrzady do pomiaru objetosci – dozowniki Wzorcowanie – objetosc Grawimetrycznie (CSN EN ISO 8655-6; EURAMET cg-19, wersja 3.0, 09/2018; ISO/TR 20461:2023-02) od 0,01 ml do 100 ml CMC 0,06 %+ 0,03µl Pistova objemova meridla – davkovace Kalibrace – objem Gravimetricky (CSN EN ISO 8655-6; EURAMET cg-19, verze 3.0, 09/2018; ISO/TR 20461:2023-02) 0,01 ml az 100 ml CMC 0,06 %+ 0,03µl SOP2","search_en":"Piston-operated volumetric instruments – dispensers Calibration – volume Gravimetrically (ČSN EN ISO 8655-6; EURAMET cg-19, version 3.0, 09/2018; ISO/TR 20461:2023-02) 0,01 ml to 100 ml CMC 0,06 %+ 0,03µl SOP2","search_zh":"活塞式容量器具 – 分液器 校准 – 体积 称量法（ČSN EN ISO 8655-6；EURAMET cg-19，3.0 版，09/2018；ISO/TR 20461:2023-02） 0,01 ml 至 100 ml CMC 0,06 %+ 0,03µl SOP2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e818df806481cc56e6ad1193","lab_id":"6ade8b3eff06824761708127","country":"CZ","accr_number":"2373","accr_body":"ČIA","row_label":"1","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -85 °C do -50 °C","cmc":"0,60 °C"},{"name":"","range":"od -50 °C do 0 °C","cmc":"0,30 °C"}],"parameters_en":[{"name":"","range":"-85 °C to -50 °C","cmc":"0,60 °C"},{"name":"","range":"-50 °C to 0 °C","cmc":"0,30 °C"}],"parameters_zh":[{"name":"","range":"-85 °C 至 -50 °C","cmc":"0,60 °C"},{"name":"","range":"-50 °C 至 0 °C","cmc":"0,30 °C"}],"parameters_cs":[{"name":"","range":"-85 °C až -50 °C","cmc":"0,60 °C"},{"name":"","range":"-50 °C až 0 °C","cmc":"0,30 °C"}],"technique":"Porównanie z termometrem wzorcowym w termostacie klienta","technique_en":"Comparison with a standard thermometer in the customer's thermostat","technique_zh":"在客户恒温器中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v termostatu zákazníka","techniques":["Porównanie z termometrem wzorcowym w termostacie klienta"],"techniques_en":["Comparison with a standard thermometer in the customer's thermostat"],"techniques_zh":["在客户恒温器中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v termostatu zákazníka"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -85 °C do -50 °C CMC 0,60 °C\nod -50 °C do 0 °C CMC 0,30 °C\nPorównanie z termometrem wzorcowym w termostacie klienta","reference":"SOP4","norm_bases":["SOP4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w termostacie klienta od -85 °C do -50 °C CMC 0,60 °C od -50 °C do 0 °C CMC 0,30 °C Elektronické teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem v termostatu zákazníka -85 °C až -50 °C CMC 0,60 °C -50 °C až 0 °C CMC 0,30 °C SOP4 Termometry elektroniczne Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w termostacie klienta od -85 °C do -50 °C CMC 0,60 °C od -50 °C do 0 °C CMC 0,30 °C Elektronicke teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem v termostatu zakaznika -85 °C az -50 °C CMC 0,60 °C -50 °C az 0 °C CMC 0,30 °C SOP4","search_en":"Electronic thermometers Calibration – temperature Comparison with a standard thermometer in the customer's thermostat -85 °C to -50 °C CMC 0,60 °C -50 °C to 0 °C CMC 0,30 °C SOP4","search_zh":"电子温度计 校准 – 温度 在客户恒温器中与标准温度计比较 -85 °C 至 -50 °C CMC 0,60 °C -50 °C 至 0 °C CMC 0,30 °C SOP4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25c14eb6a154dcab2fb09b88","lab_id":"6ade8b3eff06824761708127","country":"CZ","accr_number":"2373","accr_body":"ČIA","row_label":"1","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 0 °C","cmc":"0,20 °C"},{"name":"","range":"od 0 °C do 80 °C","cmc":"0,13 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 0 °C","cmc":"0,20 °C"},{"name":"","range":"0 °C to 80 °C","cmc":"0,13 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 0 °C","cmc":"0,20 °C"},{"name":"","range":"0 °C 至 80 °C","cmc":"0,13 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 0 °C","cmc":"0,20 °C"},{"name":"","range":"0 °C až 80 °C","cmc":"0,13 °C"}],"technique":"Porównanie bezpośrednie w łaźni cieczowej","technique_en":"Direct comparison in a liquid bath","technique_zh":"在液体槽中直接比较","technique_cs":"Přímé porovnání v kapalinové lázni","techniques":["Porównanie bezpośrednie w łaźni cieczowej"],"techniques_en":["Direct comparison in a liquid bath"],"techniques_zh":["在液体槽中直接比较"],"techniques_cs":["Přímé porovnání v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 0 °C CMC 0,20 °C\nod 0 °C do 80 °C CMC 0,13 °C\nPorównanie bezpośrednie w łaźni cieczowej","reference":"SOP4","norm_bases":["SOP4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie bezpośrednie w łaźni cieczowej od -30 °C do 0 °C CMC 0,20 °C od 0 °C do 80 °C CMC 0,13 °C Elektronické teploměry Kalibrace – teplota Přímé porovnání v kapalinové lázni -30 °C až 0 °C CMC 0,20 °C 0 °C až 80 °C CMC 0,13 °C SOP4 Termometry elektroniczne Wzorcowanie – temperatura Porownanie bezposrednie w lazni cieczowej od -30 °C do 0 °C CMC 0,20 °C od 0 °C do 80 °C CMC 0,13 °C Elektronicke teplomery Kalibrace – teplota Prime porovnani v kapalinove lazni -30 °C az 0 °C CMC 0,20 °C 0 °C az 80 °C CMC 0,13 °C SOP4","search_en":"Electronic thermometers Calibration – temperature Direct comparison in a liquid bath -30 °C to 0 °C CMC 0,20 °C 0 °C to 80 °C CMC 0,13 °C SOP4","search_zh":"电子温度计 校准 – 温度 在液体槽中直接比较 -30 °C 至 0 °C CMC 0,20 °C 0 °C 至 80 °C CMC 0,13 °C SOP4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7be722a0b455f0cded82ea82","lab_id":"6ade8b3eff06824761708127","country":"CZ","accr_number":"2373","accr_body":"ČIA","row_label":"1","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 80 °C do 100 °C","cmc":"0,14 °C"},{"name":"","range":"od 100 °C do 130 °C","cmc":"0,20 °C"}],"parameters_en":[{"name":"","range":"80 °C to 100 °C","cmc":"0,14 °C"},{"name":"","range":"100 °C to 130 °C","cmc":"0,20 °C"}],"parameters_zh":[{"name":"","range":"80 °C 至 100 °C","cmc":"0,14 °C"},{"name":"","range":"100 °C 至 130 °C","cmc":"0,20 °C"}],"parameters_cs":[{"name":"","range":"80 °C až 100 °C","cmc":"0,14 °C"},{"name":"","range":"100 °C až 130 °C","cmc":"0,20 °C"}],"technique":"Porównanie bezpośrednie w suchym piecyku","technique_en":"Direct comparison in a dry-block furnace","technique_zh":"在干式炉中直接比较","technique_cs":"Přímé porovnání v suché pícce","techniques":["Porównanie bezpośrednie w suchym piecyku"],"techniques_en":["Direct comparison in a dry-block furnace"],"techniques_zh":["在干式炉中直接比较"],"techniques_cs":["Přímé porovnání v suché pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 80 °C do 100 °C CMC 0,14 °C\nod 100 °C do 130 °C CMC 0,20 °C\nPorównanie bezpośrednie w suchym piecyku","reference":"SOP4","norm_bases":["SOP4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie bezpośrednie w suchym piecyku od 80 °C do 100 °C CMC 0,14 °C od 100 °C do 130 °C CMC 0,20 °C Elektronické teploměry Kalibrace – teplota Přímé porovnání v suché pícce 80 °C až 100 °C CMC 0,14 °C 100 °C až 130 °C CMC 0,20 °C SOP4 Termometry elektroniczne Wzorcowanie – temperatura Porownanie bezposrednie w suchym piecyku od 80 °C do 100 °C CMC 0,14 °C od 100 °C do 130 °C CMC 0,20 °C Elektronicke teplomery Kalibrace – teplota Prime porovnani v suche picce 80 °C az 100 °C CMC 0,14 °C 100 °C az 130 °C CMC 0,20 °C SOP4","search_en":"Electronic thermometers Calibration – temperature Direct comparison in a dry-block furnace 80 °C to 100 °C CMC 0,14 °C 100 °C to 130 °C CMC 0,20 °C SOP4","search_zh":"电子温度计 校准 – 温度 在干式炉中直接比较 80 °C 至 100 °C CMC 0,14 °C 100 °C 至 130 °C CMC 0,20 °C SOP4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"473af175eb20e242d6d8463d","lab_id":"6ade8b3eff06824761708127","country":"CZ","accr_number":"2373","accr_body":"ČIA","row_label":"2","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 80 °C","cmc":"0,08 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 80 °C","cmc":"0,08 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 80 °C","cmc":"0,08 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 80 °C","cmc":"0,08 °C"}],"technique":"Porównanie bezpośrednie w łaźni cieczowej","technique_en":"Direct comparison in a liquid bath","technique_zh":"在液体槽中直接比较","technique_cs":"Přímé porovnání v kapalinové lázni","techniques":["Porównanie bezpośrednie w łaźni cieczowej"],"techniques_en":["Direct comparison in a liquid bath"],"techniques_zh":["在液体槽中直接比较"],"techniques_cs":["Přímé porovnání v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -30 °C do 80 °C CMC 0,08 °C\nPorównanie bezpośrednie w łaźni cieczowej","reference":"SOP3","norm_bases":["SOP3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie bezpośrednie w łaźni cieczowej od -30 °C do 80 °C CMC 0,08 °C Skleněné teploměry Kalibrace – teplota Přímé porovnání v kapalinové lázni -30 °C až 80 °C CMC 0,08 °C SOP3 Termometry szklane Wzorcowanie – temperatura Porownanie bezposrednie w lazni cieczowej od -30 °C do 80 °C CMC 0,08 °C Sklenene teplomery Kalibrace – teplota Prime porovnani v kapalinove lazni -30 °C az 80 °C CMC 0,08 °C SOP3","search_en":"Glass thermometers Calibration – temperature Direct comparison in a liquid bath -30 °C to 80 °C CMC 0,08 °C SOP3","search_zh":"玻璃温度计 校准 – 温度 在液体槽中直接比较 -30 °C 至 80 °C CMC 0,08 °C SOP3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6cc6b9c74c5861c8cb205c55","lab_id":"6ade8b3eff06824761708127","country":"CZ","accr_number":"2373","accr_body":"ČIA","row_label":"3","test_object":"Temperatura i jednorodność pola temperatury w lodówkach i zamrażarkach","test_object_en":"Temperature and temperature field homogeneity in refrigerators and freezers","test_object_zh":"冰箱和冷冻柜的温度及温度场均匀性","test_object_cs":"Teplota a homogenita teplotního pole u lednic a mrazáků","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 50 °C","cmc":"0,60 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 50 °C","cmc":"0,60 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 50 °C","cmc":"0,60 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 50 °C","cmc":"0,60 °C"}],"technique":"Porównanie wartości temperatury z rejestratora z zapisem wartości z wzorca temperatury","technique_en":"Comparison of temperature values from the data logger with the record of values from the temperature standard","technique_zh":"将数据记录器的温度值与温度标准的记录值进行比较","technique_cs":"Porovnání hodnot teploty z dataloggeru se záznamem hodnot z etalonu teploty","techniques":["Porównanie wartości temperatury z rejestratora z zapisem wartości z wzorca temperatury"],"techniques_en":["Comparison of temperature values from the data logger with the record of values from the temperature standard"],"techniques_zh":["将数据记录器的温度值与温度标准的记录值进行比较"],"techniques_cs":["Porovnání hodnot teploty z dataloggeru se záznamem hodnot z etalonu teploty"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -30 °C do 50 °C CMC 0,60 °C\nPorównanie wartości temperatury z rejestratora z zapisem wartości z wzorca temperatury","reference":"SOP6","norm_bases":["SOP6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Temperatura i jednorodność pola temperatury w lodówkach i zamrażarkach Wzorcowanie – temperatura Porównanie wartości temperatury z rejestratora z zapisem wartości z wzorca temperatury od -30 °C do 50 °C CMC 0,60 °C Teplota a homogenita teplotního pole u lednic a mrazáků Kalibrace – teplota Porovnání hodnot teploty z dataloggeru se záznamem hodnot z etalonu teploty -30 °C až 50 °C CMC 0,60 °C SOP6 Temperatura i jednorodnosc pola temperatury w lodowkach i zamrazarkach Wzorcowanie – temperatura Porownanie wartosci temperatury z rejestratora z zapisem wartosci z wzorca temperatury od -30 °C do 50 °C CMC 0,60 °C Teplota a homogenita teplotniho pole u lednic a mrazaku Kalibrace – teplota Porovnani hodnot teploty z dataloggeru se zaznamem hodnot z etalonu teploty -30 °C az 50 °C CMC 0,60 °C SOP6","search_en":"Temperature and temperature field homogeneity in refrigerators and freezers Calibration – temperature Comparison of temperature values from the data logger with the record of values from the temperature standard -30 °C to 50 °C CMC 0,60 °C SOP6","search_zh":"冰箱和冷冻柜的温度及温度场均匀性 校准 – 温度 将数据记录器的温度值与温度标准的记录值进行比较 -30 °C 至 50 °C CMC 0,60 °C SOP6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8835e259c87e8b760ae4a794","lab_id":"6ade8b3eff06824761708127","country":"CZ","accr_number":"2373","accr_body":"ČIA","row_label":"1","test_object":"Higrometry elektroniczne","test_object_en":"Electronic hygrometers","test_object_zh":"电子湿度计","test_object_cs":"Elektronické vlhkoměry","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"10 °C do 80 °C","range":"od 20 % RH do 80 % RH","cmc":"2,8 % RH"}],"parameters_en":[{"name":"10 °C to 80 °C","range":"20 % RH to 80 % RH","cmc":"2,8 % RH"}],"parameters_zh":[{"name":"10 °C 至 80 °C","range":"20 % RH 至 80 % RH","cmc":"2,8 % RH"}],"parameters_cs":[{"name":"10 °C až 80 °C","range":"20 % RH až 80 % RH","cmc":"2,8 % RH"}],"technique":"Porównanie bezpośrednie z wzorcem w komorze klimatycznej","technique_en":"Direct comparison with a standard in a climatic chamber","technique_zh":"在气候箱中与标准直接比较","technique_cs":"Přímé porovnání s etalonem v klimakomoře","techniques":["Porównanie bezpośrednie z wzorcem w komorze klimatycznej"],"techniques_en":["Direct comparison with a standard in a climatic chamber"],"techniques_zh":["在气候箱中与标准直接比较"],"techniques_cs":["Přímé porovnání s etalonem v klimakomoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\n10 °C do 80 °C od 20 % RH do 80 % RH CMC 2,8 % RH\nPorównanie bezpośrednie z wzorcem w komorze klimatycznej","reference":"SOP7","norm_bases":["SOP7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Higrometry elektroniczne Wzorcowanie – wilgotność powietrza Porównanie bezpośrednie z wzorcem w komorze klimatycznej 10 °C do 80 °C od 20 % RH do 80 % RH CMC 2,8 % RH Elektronické vlhkoměry Kalibrace – vlhkost vzduchu Přímé porovnání s etalonem v klimakomoře 10 °C až 80 °C 20 % RH až 80 % RH CMC 2,8 % RH SOP7 Higrometry elektroniczne Wzorcowanie – wilgotnosc powietrza Porownanie bezposrednie z wzorcem w komorze klimatycznej 10 °C do 80 °C od 20 % RH do 80 % RH CMC 2,8 % RH Elektronicke vlhkomery Kalibrace – vlhkost vzduchu Prime porovnani s etalonem v klimakomore 10 °C az 80 °C 20 % RH az 80 % RH CMC 2,8 % RH SOP7","search_en":"Electronic hygrometers Calibration – air humidity Direct comparison with a standard in a climatic chamber 10 °C to 80 °C 20 % RH to 80 % RH CMC 2,8 % RH SOP7","search_zh":"电子湿度计 校准 – 空气湿度 在气候箱中与标准直接比较 10 °C 至 80 °C 20 % RH 至 80 % RH CMC 2,8 % RH SOP7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}