🇨🇿 JSP, s.r.o. PL
Metrology & calibration
JSP, s.r.o. is a calibration laboratory accredited by ČIA under number 2362 (Jičín, Czech Republic). Its accreditation scope covers 28 calibration items in the following areas: Metrology & calibration. Calibrated items include: Deformation and digital manometers, pressure transducers and pressu…, Thermoelectric temperature sensors (with/without a transducer), dir…, Dial thermometers, Relative humidity / hygrometers and measuring chains incl. humidity…. Most frequently used calibration principles: Comparison with a Pt100 standard in liquid baths and dry block cali…, Comparison with a reference multimeter, Measurement by a reference multimeter.
At a glance
- Accreditation number: ČIA 2362
- Calibration items in scope: 28
- Types of calibrated items: 17
- Calibration principles used: 10
- City: Jičín, Czech Republic
- Valid until: 18-09-2029
- Accreditation number
- 2362
- Accreditation body
- ČIA
- Address
- Raisova 547, Holínské Předměstí, 506 01 Jičín
- City
- Jičín, Czech Republic
- Division
- Laboratorium wzorcujące
- Valid until
- 18-09-2029
What this laboratory calibrates (17)
- Deformation and digital manometers, pressure transducers and pressure measuring chains — 6 calibration items
- Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples — 4 calibration items
- Dial thermometers — 2 calibration items
- Relative humidity / hygrometers and measuring chains incl. humidity probes — 2 calibration items
- Resistance temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with resistance temperature sensors — 2 calibration items
- AC current / AC current meters — 1 calibration item
- AC current / AC current sources — 1 calibration item
- AC voltage / AC voltage meters — 1 calibration item
- AC voltage / AC voltage sources — 1 calibration item
- DC current / DC current meters — 1 calibration item
- DC current / DC current sources — 1 calibration item
- DC resistance / DC resistance meters — 1 calibration item
- DC resistance / DC resistance sources — 1 calibration item
- DC voltage / DC voltage meters — 1 calibration item
- DC voltage / DC voltage sources — 1 calibration item
- and 2 more
Calibration principles (10)
- Comparison with a Pt100 standard in liquid baths and dry block calibrators — 6 calibration items
- Comparison with a reference multimeter — 5 calibration items
- Measurement by a reference multimeter — 5 calibration items
- Comparison with a digital manometer — 2 calibration items
- Comparison with a piston manometer — 2 calibration items
- Comparison with a reference calibrator — 2 calibration items
- Comparison with a reference hygrometer — 2 calibration items
- Comparison with standard thermocouples in horizontal ovens — 2 calibration items
- Comparison with a Pt100 standard in liquid baths. — 1 calibration item
- Comparison with a reference multimeter, simulation by a resistance box — 1 calibration item
Laboratory sections (2)
- Workplace Jičín — 19 calibration items
- Workplace Pardubice — 9 calibration items
Laboratory locations
- JSP, s.r.o. (main site) — Raisova 547, Holínské Předměstí, 506 01 Jičín
- Pracownia Jičín — Raisova 547, Holínské Předměstí, 506 01 Jičín
- Pracownia Pardubice — budova M 84, Semtín 103, 530 02 Pardubice
Certificate information
- Certificate date
- 26.03.2026
Accreditation scope — calibration items (28)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Workplace Jičín | |||||
| 1 | Deformation and digital manometers, pressure transducers and pressure measuring chains | Calibration – pressure relative pressure; gas — -95 kPa to -15 kPa · CMC 0,04 % relative pressure; gas — -15 kPa to -2,7 kPa · CMC 0,01 % relative pressure; gas — -2,7 kPa to 2,7 kPa · CMC 0,00027 kPa relative pressure; gas — 2 kPa to 15 kPa · CMC 0,01 % relative pressure; gas — 15 kPa to 14 MPa · CMC 0,02 % absolute pressure; gas — 5 kPa to 70 kPa · CMC 0,028 kPa absolute pressure; gas — 70 kPa to 14 MPa · CMC 0,02 % + 0,014 kPa CMC for the field of measured quantity: Pressure |
Comparison with a reference calibrator | KL-PM-0101 | |
| 2 | Deformation and digital manometers, pressure transducers and pressure measuring chains | Calibration – pressure relative pressure; liquid — 0 kPa to 0,6 MPa · CMC 0,18 kPa relative pressure; liquid — 0,6 MPa to 60 MPa · CMC 0,03 % absolute pressure; liquid — 0,1 MPa to 0,7 MPa · CMC 0,28 kPa absolute pressure; liquid — 14 MPa to 60 MPa · CMC 0,03 % + 0,1 kPa CMC for the field of measured quantity: Pressure |
Comparison with a piston manometer | KL-PM-0101 | |
| 3 | Deformation and digital manometers, pressure transducers and pressure measuring chains | Calibration – pressure relative pressure; liquid — 60 MPa to 70 MPa · CMC 0,1 % absolute pressure; liquid — 60 MPa to 70 MPa · CMC 0,10 % + 0,1 kPa CMC for the field of measured quantity: Pressure |
Comparison with a digital manometer | KL-PM-0101 | |
| 4 | Resistance temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with resistance temperature sensors | Calibration – temperature -196 °C · CMC 0,15 °C -196 °C to -40 °C · CMC 0,20 °C -40 °C to 0 °C · CMC 0,05 °C 0 °C · CMC 0,04 °C 0 °C to 100 °C · CMC 0,05 °C 100 °C to 200 °C · CMC 0,06 °C 200 °C to 300 °C · CMC 0,15 °C 300 °C to 420 °C · CMC 0,18 °C 420 °C to 660 °C · CMC 0,23 °C CMC for the field of measured quantity: Temperature |
Comparison with a Pt100 standard in liquid baths and dry block calibrators | KL-PM-0001 | |
| 5 | Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples | Calibration – temperature -196 °C to -40 °C · CMC 0,6 °C -40 °C to 200 °C · CMC 0,3 °C 200 °C to 400 °C · CMC 0,6 °C 400 °C to 660 °C · CMC 0,9 °C CMC for the field of measured quantity: Temperature |
Comparison with a Pt100 standard in liquid baths and dry block calibrators | KL-PM-0002 | |
| 6 | Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples | Calibration – temperature 400 °C to 900 °C · CMC 0,9 °C 900 °C to 1100 °C · CMC 1,0 °C 1100 °C to 1200 °C · CMC 1,5 °C 1200 °C to 1400 °C · CMC 2,0 °C 1400 °C to 1553 °C · CMC 2,8 °C CMC for the field of measured quantity: Temperature |
Comparison with standard thermocouples in horizontal ovens | KL-PM-0002 | |
| 7 | Dial thermometers | Calibration – temperature -40 °C to 200 °C · CMC 0,2 °C 200 °C to 500 °C · CMC 0,7 °C 500 °C to 660 °C · CMC 1,2 °C CMC for the field of measured quantity: Temperature |
Comparison with a Pt100 standard in liquid baths and dry block calibrators | KL-PM-0005 | |
| 8 | Relative humidity / hygrometers and measuring chains incl. humidity probes | Calibration – air humidity Air Temperature (7 to 90) °C — 5 % RH to 30 % RH · CMC 1,2 % RH Air Temperature (7 to 90) °C — 30 % RH to 50 % RH · CMC 1,3 % RH Air Temperature (7 to 90) °C — 50 % RH to 70 % RH · CMC 1,4 % RH Air Temperature (7 to 90) °C — 70 % RH to 80 % RH · CMC 1,5 % RH Air Temperature (7 to 90) °C — 80 % RH to 90 % RH · CMC 1,6 % RH Air Temperature (7 to 90) °C — 90 % RH to 95 % RH · CMC 1,8 % RH CMC for the field of measured quantity: Air humidity |
Comparison with a reference hygrometer | KL-PM-0201 | |
| 9 | Measurement and simulation of temperature sensor signals (resistance temperature sensors, thermocouples) | Calibration – electrical quantities 10 Ω to 100 Ω · CMC 0,0015 % + 0,23 mΩ 0,1 kΩ to 1 kΩ · CMC 0,0013 % + 1,8 mΩ 1 kΩ to 10 kΩ · CMC 0,0015 % + 18 mΩ -10 mV to 100 mV · CMC 0,00081 % + 0,54 µV CMC for the field of measured quantity: Electrical quantities |
Comparison with a reference multimeter | KL-PM-0006 | |
| 10 | DC voltage / DC voltage meters | Calibration – electrical quantities 0 mV to 100 mV · CMC 0,00081 % + 0,54 µV 0,1 V to 1 V · CMC 0,00064 % + 2,6 µV 1 V to 10 V · CMC 0,00064 % + 7,6 µV 10 V to 100 V · CMC 0,00092 % + 97 µV 100 V to 1000 V · CMC 0,00092 % + 1,4 mV CMC for the field of measured quantity: Electrical quantities |
Comparison with a reference multimeter | KL-PM-0301 | |
| 11 | DC voltage / DC voltage sources | Calibration – electrical quantities 0 mV to 100 mV · CMC 0,00081 % + 0,54 µV 0,1 V to 1 V · CMC 0,00064 % + 2,6 µV 1 V to 10 V · CMC 0,00064 % + 7,6 µV 10 V to 100 V · CMC 0,00092 % + 97 µV 100 V to 1000 V · CMC 0,00092 % + 1,4 mV CMC for the field of measured quantity: Electrical quantities |
Measurement by a reference multimeter | KL-PM-0301 | |
| 12 | DC current / DC current meters | Calibration – electrical quantities 0 µA to 1 µA · CMC 0,033 % + 0,022 nA 1 µA to 10 µA · CMC 0,0049 % + 0,14 nA 10 µA to 100 µA · CMC 0,0012 % + 0,92 nA 0,1 mA to 1 mA · CMC 0,0012 % + 9,2 nA 1 mA to 10 mA · CMC 0,0015 % + 0,092 µA 10 mA to 100 mA · CMC 0,0049 % + 1,1 µA 0,1 A to 1 A · CMC 0,025 % + 0,019 mA 1 A to 10 A · CMC 0,058 % + 0,57 mA 10 A to 30 A · CMC 0,080 % + 5,2 mA CMC for the field of measured quantity: Electrical quantities |
Comparison with a reference multimeter | KL-PM-0301 | |
| 13 | DC current / DC current sources | Calibration – electrical quantities 0 µA to 1 µA · CMC 0,033 % + 0,022 nA 1 µA to 10 µA · CMC 0,0049 % + 0,14 nA 10 µA to 100 µA · CMC 0,0012 % + 0,92 nA 0,1 mA to 1 mA · CMC 0,0012 % + 9,2 nA 1 mA to 10 mA · CMC 0,0015 % + 0,092 µA 10 mA to 100 mA · CMC 0,0049 % + 1,1 µA 0,1 A to 1 A · CMC 0,025 % + 0,019 mA 1 A to 10 A · CMC 0,058 % + 0,57 mA 10 A to 30 A · CMC 0,080 % + 5,2 mA CMC for the field of measured quantity: Electrical quantities |
Measurement by a reference multimeter | KL-PM-0301 | |
| 14 | AC voltage / AC voltage meters | Calibration – electrical quantities 10 Hz to 100 kHz — 0 mV to 100 mV · CMC 0,028 % + 32 µV 10 Hz to 100 kHz — 0,1 V to 1 V · CMC 0,025 % + 0,14 mV 10 Hz to 100 kHz — 1 V to 10 V · CMC 0,025 % + 1,4 mV 10 Hz to 50 kHz — 10 V to 100 V · CMC 0,029 % + 28 mV 10 Hz to 10 kHz — 100 V to 1000 V · CMC 0,029 % + 0,36 V CMC for the field of measured quantity: Electrical quantities |
Comparison with a reference multimeter | KL-PM-0301 | |
| 15 | AC voltage / AC voltage sources | Calibration – electrical quantities 10 Hz to 100 kHz — 0 mV to 100 mV · CMC 0,028 % + 32 µV 10 Hz to 100 kHz — 0,1 V to 1 V · CMC 0,025 % + 0,14 mV 10 Hz to 100 kHz — 1 V to 10 V · CMC 0,025 % + 1,4 mV 10 Hz to 50 kHz — 10 V to 100 V · CMC 0,029 % + 28 mV 10 Hz to 10 kHz — 100 V to 1000 V · CMC 0,029 % + 0,36 V CMC for the field of measured quantity: Electrical quantities |
Measurement by a reference multimeter | KL-PM-0301 | |
| 16 | AC current / AC current meters | Calibration – electrical quantities 20 Hz to 2 kHz — 1 µA to 100 µA · CMC 0,049 % + 25 nA 20 Hz to 10 kHz — 0,1 mA to 1 mA · CMC 0,049 % + 0,24 µA 20 Hz to 10 kHz — 1 mA to 10 mA · CMC 0,049 % + 2,4 µA 20 Hz to 10 kHz — 10 mA to 100 mA · CMC 0,049 % + 24 µA 20 Hz to 10 kHz — 0,1 to 1 A · CMC 0,065 % +0,26 mA 20 Hz to 1 kHz — 1 to 10 A · CMC 0,12 % + 43 mA 20 Hz to 1 kHz — 10 to 30 A · CMC 0,12 % + 131 mA CMC for the field of measured quantity: Electrical quantities |
Comparison with a reference multimeter | KL-PM-0301 | |
| 17 | AC current / AC current sources | Calibration – electrical quantities 20 Hz to 2 kHz — 1 µA to 100 µA · CMC 0,049 % + 25 nA 20 Hz to 10 kHz — 0,1 mA to 1 mA · CMC 0,049 % + 0,24 µA 20 Hz to 10 kHz — 1 mA to 10 mA · CMC 0,049 % + 2,4 µA 20 Hz to 10 kHz — 10 mA to 100 mA · CMC 0,049 % + 24 µA 20 Hz to 10 kHz — 0,1 to 1 A · CMC 0,065 % +0,26 mA 20 Hz to 1 kHz — 1 to 10 A · CMC 0,12 % + 43 mA 20 Hz to 1 kHz — 10 to 30 A · CMC 0,12 % + 131 mA CMC for the field of measured quantity: Electrical quantities |
Measurement by a reference multimeter | KL-PM-0301 | |
| 18 | DC resistance / DC resistance meters | Calibration – electrical quantities 0 Ω to 1 Ω · CMC 0,0025 % + 7,5 µΩ 1 Ω to 10 Ω · CMC 0,0017 % + 45 µΩ 10 Ω to 100 Ω · CMC 0,0015 % + 0,23 mΩ 0,1 kΩ to 1 kΩ · CMC 0,0013 % + 1,8 mΩ 1 kΩ to 10 kΩ · CMC 0,0015 % + 18 mΩ 10 kΩ to 100 kΩ · CMC 0,0017 % + 0,36 Ω 0,1 MΩ to 1 MΩ · CMC 0,0018 % + 3,9 Ω 1 MΩ to 10 MΩ · CMC 0,0025 % + 105 Ω 10 MΩ to 100 MΩ · CMC 0,12 % 100 MΩ to 1 GΩ · CMC 0,24 % 1 GΩ to 10 GΩ · CMC 0,59 % 10 GΩ to 100 GΩ · CMC 1,2 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a reference multimeter, simulation by a resistance box | KL-PM-0301 | |
| 19 | DC resistance / DC resistance sources | Calibration – electrical quantities 0 Ω to 1 Ω · CMC 0,0025 % + 7,5 µΩ 1 Ω to 10 Ω · CMC 0,0017 % + 45 µΩ 10 Ω to 100 Ω · CMC 0,0015 % + 0,23 mΩ 0,1 kΩ to 1 kΩ · CMC 0,0013 % + 1,8 mΩ 1 kΩ to 10 kΩ · CMC 0,0015 % + 18 mΩ 10 kΩ to 100 kΩ · CMC 0,0017 % + 0,36 Ω 0,1 MΩ to 1 MΩ · CMC 0,0018 % + 3,9 Ω 1 MΩ to 10 MΩ · CMC 0,0025 % + 105 Ω 10 MΩ to 90 MΩ · CMC 0,025 % 90 MΩ to 900 MΩ · CMC 0,18 % 900 MΩ to 9 GΩ · CMC 0,50 % 9 GΩ to 100 GΩ · CMC 3,8 % CMC for the field of measured quantity: Electrical quantities |
Measurement by a reference multimeter | KL-PM-0301 | |
| Workplace Pardubice | |||||
| 20 | Deformation and digital manometers, pressure transducers and pressure measuring chains | Calibration – pressure relative pressure; gas — -95 kPa to -15 kPa · CMC 0,04 % relative pressure; gas — -15 kPa to -2,7 kPa · CMC 0,01 % relative pressure; gas — -2,7 kPa to 2,7 kPa · CMC 0,00027 kPa relative pressure; gas — 2 kPa to 15 kPa · CMC 0,01 % relative pressure; gas — 15 kPa to 14 MPa · CMC 0,02 % absolute pressure; gas — 5 kPa to 70 kPa · CMC 0,028 kPa absolute pressure; gas — 70 kPa to 14 MPa · CMC 0,02 % + 0,014 kPa CMC for the field of measured quantity: Pressure |
Comparison with a reference calibrator | KL-PM-0101 | |
| 21 | Deformation and digital manometers, pressure transducers and pressure measuring chains | Calibration – pressure relative pressure; liquid — 0 kPa to 0,6 MPa · CMC 0,18 kPa relative pressure; liquid — 0,6 MPa to 60 MPa · CMC 0,03 % absolute pressure; liquid — 0,1 MPa to 0,7 MPa · CMC 0,28 kPa absolute pressure; liquid — 14 MPa to 60 MPa · CMC 0,03 % + 0,1 kPa CMC for the field of measured quantity: Pressure |
Comparison with a piston manometer | KL-PM-0101 | |
| 22 | Deformation and digital manometers, pressure transducers and pressure measuring chains | Calibration – pressure relative pressure; liquid — 60 MPa to 70 MPa · CMC 0,1 % absolute pressure; liquid — 60 MPa to 70 MPa · CMC 0,10 % + 0,1 kPa CMC for the field of measured quantity: Pressure |
Comparison with a digital manometer | KL-PM-0101 | |
| 23 | Resistance temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with resistance temperature sensors | Calibration – temperature -196 °C · CMC 0,15 °C -196 °C to -40 °C · CMC 0,20 °C -40 °C to 0 °C · CMC 0,05 °C 0 °C · CMC 0,04 °C 0 °C to 100 °C · CMC 0,05 °C 100 °C to 200 °C · CMC 0,06 °C 200 °C to 300 °C · CMC 0,15 °C 300 °C to 420 °C · CMC 0,18 °C 420 °C to 660 °C · CMC 0,23 °C CMC for the field of measured quantity: Temperature |
Comparison with a Pt100 standard in liquid baths and dry block calibrators | KL-PM-0001 | |
| 24 | Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples | Calibration – temperature -196 °C to -40 °C · CMC 0,6 °C -40 °C to 200 °C · CMC 0,3 °C 200 °C to 400 °C · CMC 0,6 °C 400 °C to 660 °C · CMC 0,9 °C CMC for the field of measured quantity: Temperature |
Comparison with a Pt100 standard in liquid baths and dry block calibrators | KL-PM-0002 | |
| 25 | Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples | Calibration – temperature 400 °C to 900 °C · CMC 0,9 °C 900 °C to 1100 °C · CMC 1,0 °C 1100 °C to 1200 °C · CMC 1,5 °C 1200 °C to 1400 °C · CMC 2,0 °C 1400 °C to 1553 °C · CMC 2,8 °C CMC for the field of measured quantity: Temperature |
Comparison with standard thermocouples in horizontal ovens | KL-PM-0002 | |
| 26 | Dial thermometers | Calibration – temperature -40 °C to 200 °C · CMC 0,2 °C 200 °C to 500 °C · CMC 0,7 °C 500 °C to 660 °C · CMC 1,2 °C CMC for the field of measured quantity: Temperature |
Comparison with a Pt100 standard in liquid baths and dry block calibrators | KL-PM-0005 | |
| 27 | Glass thermometers | Calibration – temperature -40 °C to 0 °C · CMC 0,06 °C 0 °C · CMC 0,05 °C 0 °C to 100 °C · CMC 0,06 °C 100 °C to 230 °C · CMC 0,07 °C CMC for the field of measured quantity: Temperature |
Comparison with a Pt100 standard in liquid baths. | KL-PM-0005 | |
| 28 | Relative humidity / hygrometers and measuring chains incl. humidity probes | Calibration – air humidity Air Temperature (7 to 90) °C — 5 % RH to 30 % RH · CMC 1,2 % RH Air Temperature (7 to 90) °C — 30 % RH to 50 % RH · CMC 1,3 % RH Air Temperature (7 to 90) °C — 50 % RH to 70 % RH · CMC 1,4 % RH Air Temperature (7 to 90) °C — 70 % RH to 80 % RH · CMC 1,5 % RH Air Temperature (7 to 90) °C — 80 % RH to 90 % RH · CMC 1,6 % RH Air Temperature (7 to 90) °C — 90 % RH to 95 % RH · CMC 1,8 % RH CMC for the field of measured quantity: Air humidity |
Comparison with a reference hygrometer | KL-PM-0201 | |
Reference standards (7)
KL-PM-0001
KL-PM-0002
KL-PM-0005
KL-PM-0006
KL-PM-0101
KL-PM-0201
KL-PM-0301