{"lab":{"_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","categories":["metrology"],"city":"Jičín","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[15.345736,50.4345552]},"map_coord":[50.4345552,15.345736],"map_geo":"cai-mapa","methods_count":28,"name":"JSP, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów do pomiaru ciśnienia, temperatury, wilgotności powietrza i wielkości elektrycznych, w zakresie określonym w załączniku do świadectwa.","search_text":"jsp, s.r.o. raisova 547, holínské předměstí, 506 01 jičín 2362","source_page_url":"https://www.cai.cz/?subjekt=2362-jsp-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"18-09-2029","website":"www.jsp.cz","certificate_date":"26.03.2026","certificate_no":"146/2026","certificate_replaces":"487/2024 z 18.09.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów do pomiaru ciśnienia, temperatury, wilgotności powietrza i wielkości elektrycznych, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of meters of pressure, temperature, humidity and electrical quantities to the extent as specified in the appendix to this Certificate.","zh":"压力、温度、空气湿度和电学量测量仪器的校准，范围见本证书附件。","cs":"Kalibrace měřidel tlaku, teploty, vlhkosti vzduchu a elektrických veličin, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","lab_locations":[{"code":null,"name":"JSP, s.r.o.","street":"Raisova 547, Holínské Předměstí","postal_code":"506 01","city":"Jičín","is_hq":true,"address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","site":"50601|raisova547holínsképředměstí"},{"code":null,"name":"Pracownia Jičín","street":"Raisova 547, Holínské Předměstí","postal_code":"506 01","city":"Jičín","is_hq":false,"address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","site":"50601|raisova547holínsképředměstí"},{"code":null,"name":"Pracownia Pardubice","street":"budova M 84, Semtín 103","postal_code":"530 02","city":"Pardubice","is_hq":false,"address":"budova M 84, Semtín 103, 530 02 Pardubice","site":"53002|budovam84semtín103"}],"lab_locations_en":[{"code":null,"name":"JSP, s.r.o.","street":"Raisova 547, Holínské Předměstí","postal_code":"506 01","city":"Jičín","is_hq":true,"address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","site":"50601|raisova547holínsképředměstí"},{"code":null,"name":"Workplace Jičín","street":"Raisova 547, Holínské Předměstí","postal_code":"506 01","city":"Jičín","is_hq":false,"address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","site":"50601|raisova547holínsképředměstí"},{"code":null,"name":"Workplace Pardubice","street":"budova M 84, Semtín 103","postal_code":"530 02","city":"Pardubice","is_hq":false,"address":"budova M 84, Semtín 103, 530 02 Pardubice","site":"53002|budovam84semtín103"}],"lab_locations_zh":[{"code":null,"name":"JSP, s.r.o.","street":"Raisova 547, Holínské Předměstí","postal_code":"506 01","city":"Jičín","is_hq":true,"address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","site":"50601|raisova547holínsképředměstí"},{"code":null,"name":"Jičín 工作场所","street":"Raisova 547, Holínské Předměstí","postal_code":"506 01","city":"Jičín","is_hq":false,"address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","site":"50601|raisova547holínsképředměstí"},{"code":null,"name":"Pardubice 工作场所","street":"budova M 84, Semtín 103","postal_code":"530 02","city":"Pardubice","is_hq":false,"address":"budova M 84, Semtín 103, 530 02 Pardubice","site":"53002|budovam84semtín103"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników wzorcowań.","en":"The laboratory provides opinions and interpretations of the calibration results.","zh":"实验室提供校准结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků kalibrací."}],"source_lang":"cs","source_pdf_sha256":"6e79bd0d7c5c56d282fda3bcafcf671850473e4cd7a8a24409ead6ad64a57382","source_pdf_url":"https://www.cai.cz/OA/pdf/146_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/146_2026_EN.pdf"},"methods":[{"_id":"96bcb0a2f3230311419f3296","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器和压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"ciśnienie względne; gaz","range":"od -95 kPa do -15 kPa","cmc":"0,04 %"},{"name":"ciśnienie względne; gaz","range":"od -15 kPa do -2,7 kPa","cmc":"0,01 %"},{"name":"ciśnienie względne; gaz","range":"od -2,7 kPa do 2,7 kPa","cmc":"0,00027 kPa"},{"name":"ciśnienie względne; gaz","range":"od 2 kPa do 15 kPa","cmc":"0,01 %"},{"name":"ciśnienie względne; gaz","range":"od 15 kPa do 14 MPa","cmc":"0,02 %"},{"name":"ciśnienie bezwzględne; gaz","range":"od 5 kPa do 70 kPa","cmc":"0,028 kPa"},{"name":"ciśnienie bezwzględne; gaz","range":"od 70 kPa do 14 MPa","cmc":"0,02 % + 0,014 kPa"}],"parameters_en":[{"name":"relative pressure; gas","range":"-95 kPa to -15 kPa","cmc":"0,04 %"},{"name":"relative pressure; gas","range":"-15 kPa to -2,7 kPa","cmc":"0,01 %"},{"name":"relative pressure; gas","range":"-2,7 kPa to 2,7 kPa","cmc":"0,00027 kPa"},{"name":"relative pressure; gas","range":"2 kPa to 15 kPa","cmc":"0,01 %"},{"name":"relative pressure; gas","range":"15 kPa to 14 MPa","cmc":"0,02 %"},{"name":"absolute pressure; gas","range":"5 kPa to 70 kPa","cmc":"0,028 kPa"},{"name":"absolute pressure; gas","range":"70 kPa to 14 MPa","cmc":"0,02 % + 0,014 kPa"}],"parameters_zh":[{"name":"相对压力；气体","range":"-95 kPa 至 -15 kPa","cmc":"0,04 %"},{"name":"相对压力；气体","range":"-15 kPa 至 -2,7 kPa","cmc":"0,01 %"},{"name":"相对压力；气体","range":"-2,7 kPa 至 2,7 kPa","cmc":"0,00027 kPa"},{"name":"相对压力；气体","range":"2 kPa 至 15 kPa","cmc":"0,01 %"},{"name":"相对压力；气体","range":"15 kPa 至 14 MPa","cmc":"0,02 %"},{"name":"绝对压力；气体","range":"5 kPa 至 70 kPa","cmc":"0,028 kPa"},{"name":"绝对压力；气体","range":"70 kPa 至 14 MPa","cmc":"0,02 % + 0,014 kPa"}],"parameters_cs":[{"name":"tlak relativní; plyn","range":"-95 kPa až -15 kPa","cmc":"0,04 %"},{"name":"tlak relativní; plyn","range":"-15 kPa až -2,7 kPa","cmc":"0,01 %"},{"name":"tlak relativní; plyn","range":"-2,7 kPa až 2,7 kPa","cmc":"0,00027 kPa"},{"name":"tlak relativní; plyn","range":"2 kPa až 15 kPa","cmc":"0,01 %"},{"name":"tlak relativní; plyn","range":"15 kPa až 14 MPa","cmc":"0,02 %"},{"name":"tlak absolutní; plyn","range":"5 kPa až 70 kPa","cmc":"0,028 kPa"},{"name":"tlak absolutní; plyn","range":"70 kPa až 14 MPa","cmc":"0,02 % + 0,014 kPa"}],"technique":"Porównanie z kalibratorem wzorcowym","technique_en":"Comparison with a reference calibrator","technique_zh":"与标准校准器比较","technique_cs":"Porovnání s etalonovým kalibrátorem","techniques":["Porównanie z kalibratorem wzorcowym"],"techniques_en":["Comparison with a reference calibrator"],"techniques_zh":["与标准校准器比较"],"techniques_cs":["Porovnání s etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nciśnienie względne; gaz od -95 kPa do -15 kPa CMC 0,04 %\nciśnienie względne; gaz od -15 kPa do -2,7 kPa CMC 0,01 %\nciśnienie względne; gaz od -2,7 kPa do 2,7 kPa CMC 0,00027 kPa\nciśnienie względne; gaz od 2 kPa do 15 kPa CMC 0,01 %\nciśnienie względne; gaz od 15 kPa do 14 MPa CMC 0,02 %\nciśnienie bezwzględne; gaz od 5 kPa do 70 kPa CMC 0,028 kPa\nciśnienie bezwzględne; gaz od 70 kPa do 14 MPa CMC 0,02 % + 0,014 kPa\nPorównanie z kalibratorem wzorcowym","reference":"KL-PM-0101","norm_bases":["KL-PM-0101"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z kalibratorem wzorcowym ciśnienie względne; gaz od -95 kPa do -15 kPa CMC 0,04 % ciśnienie względne; gaz od -15 kPa do -2,7 kPa CMC 0,01 % ciśnienie względne; gaz od -2,7 kPa do 2,7 kPa CMC 0,00027 kPa ciśnienie względne; gaz od 2 kPa do 15 kPa CMC 0,01 % ciśnienie względne; gaz od 15 kPa do 14 MPa CMC 0,02 % ciśnienie bezwzględne; gaz od 5 kPa do 70 kPa CMC 0,028 kPa ciśnienie bezwzględne; gaz od 70 kPa do 14 MPa CMC 0,02 % + 0,014 kPa Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku Kalibrace – tlak Porovnání s etalonovým kalibrátorem tlak relativní; plyn -95 kPa až -15 kPa CMC 0,04 % tlak relativní; plyn -15 kPa až -2,7 kPa CMC 0,01 % tlak relativní; plyn -2,7 kPa až 2,7 kPa CMC 0,00027 kPa tlak relativní; plyn 2 kPa až 15 kPa CMC 0,01 % tlak relativní; plyn 15 kPa až 14 MPa CMC 0,02 % tlak absolutní; plyn 5 kPa až 70 kPa CMC 0,028 kPa tlak absolutní; plyn 70 kPa až 14 MPa CMC 0,02 % + 0,014 kPa KL-PM-0101 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia i tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z kalibratorem wzorcowym cisnienie wzgledne; gaz od -95 kPa do -15 kPa CMC 0,04 % cisnienie wzgledne; gaz od -15 kPa do -2,7 kPa CMC 0,01 % cisnienie wzgledne; gaz od -2,7 kPa do 2,7 kPa CMC 0,00027 kPa cisnienie wzgledne; gaz od 2 kPa do 15 kPa CMC 0,01 % cisnienie wzgledne; gaz od 15 kPa do 14 MPa CMC 0,02 % cisnienie bezwzgledne; gaz od 5 kPa do 70 kPa CMC 0,028 kPa cisnienie bezwzgledne; gaz od 70 kPa do 14 MPa CMC 0,02 % + 0,014 kPa Deformacni a cislicove tlakomery, prevodniky tlaku a merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym kalibratorem tlak relativni; plyn -95 kPa az -15 kPa CMC 0,04 % tlak relativni; plyn -15 kPa az -2,7 kPa CMC 0,01 % tlak relativni; plyn -2,7 kPa az 2,7 kPa CMC 0,00027 kPa tlak relativni; plyn 2 kPa az 15 kPa CMC 0,01 % tlak relativni; plyn 15 kPa az 14 MPa CMC 0,02 % tlak absolutni; plyn 5 kPa az 70 kPa CMC 0,028 kPa tlak absolutni; plyn 70 kPa az 14 MPa CMC 0,02 % + 0,014 kPa KL-PM-0101","search_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains Calibration – pressure Comparison with a reference calibrator relative pressure; gas -95 kPa to -15 kPa CMC 0,04 % relative pressure; gas -15 kPa to -2,7 kPa CMC 0,01 % relative pressure; gas -2,7 kPa to 2,7 kPa CMC 0,00027 kPa relative pressure; gas 2 kPa to 15 kPa CMC 0,01 % relative pressure; gas 15 kPa to 14 MPa CMC 0,02 % absolute pressure; gas 5 kPa to 70 kPa CMC 0,028 kPa absolute pressure; gas 70 kPa to 14 MPa CMC 0,02 % + 0,014 kPa KL-PM-0101","search_zh":"弹性式和数字式压力表、压力变送器和压力测量链 校准 – 压力 与标准校准器比较 相对压力；气体 -95 kPa 至 -15 kPa CMC 0,04 % 相对压力；气体 -15 kPa 至 -2,7 kPa CMC 0,01 % 相对压力；气体 -2,7 kPa 至 2,7 kPa CMC 0,00027 kPa 相对压力；气体 2 kPa 至 15 kPa CMC 0,01 % 相对压力；气体 15 kPa 至 14 MPa CMC 0,02 % 绝对压力；气体 5 kPa 至 70 kPa CMC 0,028 kPa 绝对压力；气体 70 kPa 至 14 MPa CMC 0,02 % + 0,014 kPa KL-PM-0101","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6f63e9b741cd8aea79b5eab4","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器和压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"ciśnienie względne; gaz","range":"od -95 kPa do -15 kPa","cmc":"0,04 %"},{"name":"ciśnienie względne; gaz","range":"od -15 kPa do -2,7 kPa","cmc":"0,01 %"},{"name":"ciśnienie względne; gaz","range":"od -2,7 kPa do 2,7 kPa","cmc":"0,00027 kPa"},{"name":"ciśnienie względne; gaz","range":"od 2 kPa do 15 kPa","cmc":"0,01 %"},{"name":"ciśnienie względne; gaz","range":"od 15 kPa do 14 MPa","cmc":"0,02 %"},{"name":"ciśnienie bezwzględne; gaz","range":"od 5 kPa do 70 kPa","cmc":"0,028 kPa"},{"name":"ciśnienie bezwzględne; gaz","range":"od 70 kPa do 14 MPa","cmc":"0,02 % + 0,014 kPa"}],"parameters_en":[{"name":"relative pressure; gas","range":"-95 kPa to -15 kPa","cmc":"0,04 %"},{"name":"relative pressure; gas","range":"-15 kPa to -2,7 kPa","cmc":"0,01 %"},{"name":"relative pressure; gas","range":"-2,7 kPa to 2,7 kPa","cmc":"0,00027 kPa"},{"name":"relative pressure; gas","range":"2 kPa to 15 kPa","cmc":"0,01 %"},{"name":"relative pressure; gas","range":"15 kPa to 14 MPa","cmc":"0,02 %"},{"name":"absolute pressure; gas","range":"5 kPa to 70 kPa","cmc":"0,028 kPa"},{"name":"absolute pressure; gas","range":"70 kPa to 14 MPa","cmc":"0,02 % + 0,014 kPa"}],"parameters_zh":[{"name":"相对压力；气体","range":"-95 kPa 至 -15 kPa","cmc":"0,04 %"},{"name":"相对压力；气体","range":"-15 kPa 至 -2,7 kPa","cmc":"0,01 %"},{"name":"相对压力；气体","range":"-2,7 kPa 至 2,7 kPa","cmc":"0,00027 kPa"},{"name":"相对压力；气体","range":"2 kPa 至 15 kPa","cmc":"0,01 %"},{"name":"相对压力；气体","range":"15 kPa 至 14 MPa","cmc":"0,02 %"},{"name":"绝对压力；气体","range":"5 kPa 至 70 kPa","cmc":"0,028 kPa"},{"name":"绝对压力；气体","range":"70 kPa 至 14 MPa","cmc":"0,02 % + 0,014 kPa"}],"parameters_cs":[{"name":"tlak relativní; plyn","range":"-95 kPa až -15 kPa","cmc":"0,04 %"},{"name":"tlak relativní; plyn","range":"-15 kPa až -2,7 kPa","cmc":"0,01 %"},{"name":"tlak relativní; plyn","range":"-2,7 kPa až 2,7 kPa","cmc":"0,00027 kPa"},{"name":"tlak relativní; plyn","range":"2 kPa až 15 kPa","cmc":"0,01 %"},{"name":"tlak relativní; plyn","range":"15 kPa až 14 MPa","cmc":"0,02 %"},{"name":"tlak absolutní; plyn","range":"5 kPa až 70 kPa","cmc":"0,028 kPa"},{"name":"tlak absolutní; plyn","range":"70 kPa až 14 MPa","cmc":"0,02 % + 0,014 kPa"}],"technique":"Porównanie z kalibratorem wzorcowym","technique_en":"Comparison with a reference calibrator","technique_zh":"与标准校准器比较","technique_cs":"Porovnání s etalonovým kalibrátorem","techniques":["Porównanie z kalibratorem wzorcowym"],"techniques_en":["Comparison with a reference calibrator"],"techniques_zh":["与标准校准器比较"],"techniques_cs":["Porovnání s etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nciśnienie względne; gaz od -95 kPa do -15 kPa CMC 0,04 %\nciśnienie względne; gaz od -15 kPa do -2,7 kPa CMC 0,01 %\nciśnienie względne; gaz od -2,7 kPa do 2,7 kPa CMC 0,00027 kPa\nciśnienie względne; gaz od 2 kPa do 15 kPa CMC 0,01 %\nciśnienie względne; gaz od 15 kPa do 14 MPa CMC 0,02 %\nciśnienie bezwzględne; gaz od 5 kPa do 70 kPa CMC 0,028 kPa\nciśnienie bezwzględne; gaz od 70 kPa do 14 MPa CMC 0,02 % + 0,014 kPa\nPorównanie z kalibratorem wzorcowym","reference":"KL-PM-0101","norm_bases":["KL-PM-0101"],"lab_section":"Pracownia Pardubice","lab_section_en":"Workplace Pardubice","lab_section_zh":"Pardubice 工作场所","lab_section_cs":"Pracoviště Pardubice","lab_address":"budova M 84, Semtín 103, 530 02 Pardubice","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z kalibratorem wzorcowym ciśnienie względne; gaz od -95 kPa do -15 kPa CMC 0,04 % ciśnienie względne; gaz od -15 kPa do -2,7 kPa CMC 0,01 % ciśnienie względne; gaz od -2,7 kPa do 2,7 kPa CMC 0,00027 kPa ciśnienie względne; gaz od 2 kPa do 15 kPa CMC 0,01 % ciśnienie względne; gaz od 15 kPa do 14 MPa CMC 0,02 % ciśnienie bezwzględne; gaz od 5 kPa do 70 kPa CMC 0,028 kPa ciśnienie bezwzględne; gaz od 70 kPa do 14 MPa CMC 0,02 % + 0,014 kPa Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku Kalibrace – tlak Porovnání s etalonovým kalibrátorem tlak relativní; plyn -95 kPa až -15 kPa CMC 0,04 % tlak relativní; plyn -15 kPa až -2,7 kPa CMC 0,01 % tlak relativní; plyn -2,7 kPa až 2,7 kPa CMC 0,00027 kPa tlak relativní; plyn 2 kPa až 15 kPa CMC 0,01 % tlak relativní; plyn 15 kPa až 14 MPa CMC 0,02 % tlak absolutní; plyn 5 kPa až 70 kPa CMC 0,028 kPa tlak absolutní; plyn 70 kPa až 14 MPa CMC 0,02 % + 0,014 kPa KL-PM-0101 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia i tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z kalibratorem wzorcowym cisnienie wzgledne; gaz od -95 kPa do -15 kPa CMC 0,04 % cisnienie wzgledne; gaz od -15 kPa do -2,7 kPa CMC 0,01 % cisnienie wzgledne; gaz od -2,7 kPa do 2,7 kPa CMC 0,00027 kPa cisnienie wzgledne; gaz od 2 kPa do 15 kPa CMC 0,01 % cisnienie wzgledne; gaz od 15 kPa do 14 MPa CMC 0,02 % cisnienie bezwzgledne; gaz od 5 kPa do 70 kPa CMC 0,028 kPa cisnienie bezwzgledne; gaz od 70 kPa do 14 MPa CMC 0,02 % + 0,014 kPa Deformacni a cislicove tlakomery, prevodniky tlaku a merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym kalibratorem tlak relativni; plyn -95 kPa az -15 kPa CMC 0,04 % tlak relativni; plyn -15 kPa az -2,7 kPa CMC 0,01 % tlak relativni; plyn -2,7 kPa az 2,7 kPa CMC 0,00027 kPa tlak relativni; plyn 2 kPa az 15 kPa CMC 0,01 % tlak relativni; plyn 15 kPa az 14 MPa CMC 0,02 % tlak absolutni; plyn 5 kPa az 70 kPa CMC 0,028 kPa tlak absolutni; plyn 70 kPa az 14 MPa CMC 0,02 % + 0,014 kPa KL-PM-0101","search_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains Calibration – pressure Comparison with a reference calibrator relative pressure; gas -95 kPa to -15 kPa CMC 0,04 % relative pressure; gas -15 kPa to -2,7 kPa CMC 0,01 % relative pressure; gas -2,7 kPa to 2,7 kPa CMC 0,00027 kPa relative pressure; gas 2 kPa to 15 kPa CMC 0,01 % relative pressure; gas 15 kPa to 14 MPa CMC 0,02 % absolute pressure; gas 5 kPa to 70 kPa CMC 0,028 kPa absolute pressure; gas 70 kPa to 14 MPa CMC 0,02 % + 0,014 kPa KL-PM-0101","search_zh":"弹性式和数字式压力表、压力变送器和压力测量链 校准 – 压力 与标准校准器比较 相对压力；气体 -95 kPa 至 -15 kPa CMC 0,04 % 相对压力；气体 -15 kPa 至 -2,7 kPa CMC 0,01 % 相对压力；气体 -2,7 kPa 至 2,7 kPa CMC 0,00027 kPa 相对压力；气体 2 kPa 至 15 kPa CMC 0,01 % 相对压力；气体 15 kPa 至 14 MPa CMC 0,02 % 绝对压力；气体 5 kPa 至 70 kPa CMC 0,028 kPa 绝对压力；气体 70 kPa 至 14 MPa CMC 0,02 % + 0,014 kPa KL-PM-0101","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1fe2042f22a1523692377ac5","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器和压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"ciśnienie względne; ciecz","range":"od 0 kPa do 0,6 MPa","cmc":"0,18 kPa"},{"name":"ciśnienie względne; ciecz","range":"od 0,6 MPa do 60 MPa","cmc":"0,03 %"},{"name":"ciśnienie bezwzględne; ciecz","range":"od 0,1 MPa do 0,7 MPa","cmc":"0,28 kPa"},{"name":"ciśnienie bezwzględne; ciecz","range":"od 14 MPa do 60 MPa","cmc":"0,03 % + 0,1 kPa"}],"parameters_en":[{"name":"relative pressure; liquid","range":"0 kPa to 0,6 MPa","cmc":"0,18 kPa"},{"name":"relative pressure; liquid","range":"0,6 MPa to 60 MPa","cmc":"0,03 %"},{"name":"absolute pressure; liquid","range":"0,1 MPa to 0,7 MPa","cmc":"0,28 kPa"},{"name":"absolute pressure; liquid","range":"14 MPa to 60 MPa","cmc":"0,03 % + 0,1 kPa"}],"parameters_zh":[{"name":"相对压力；液体","range":"0 kPa 至 0,6 MPa","cmc":"0,18 kPa"},{"name":"相对压力；液体","range":"0,6 MPa 至 60 MPa","cmc":"0,03 %"},{"name":"绝对压力；液体","range":"0,1 MPa 至 0,7 MPa","cmc":"0,28 kPa"},{"name":"绝对压力；液体","range":"14 MPa 至 60 MPa","cmc":"0,03 % + 0,1 kPa"}],"parameters_cs":[{"name":"tlak relativní; kapalina","range":"0 kPa až 0,6 MPa","cmc":"0,18 kPa"},{"name":"tlak relativní; kapalina","range":"0,6 MPa až 60 MPa","cmc":"0,03 %"},{"name":"tlak absolutní; kapalina","range":"0,1 MPa až 0,7 MPa","cmc":"0,28 kPa"},{"name":"tlak absolutní; kapalina","range":"14 MPa až 60 MPa","cmc":"0,03 % + 0,1 kPa"}],"technique":"Porównanie z manometrem tłokowym","technique_en":"Comparison with a piston manometer","technique_zh":"与活塞式压力计比较","technique_cs":"Porovnání s pístovým tlakoměrem","techniques":["Porównanie z manometrem tłokowym"],"techniques_en":["Comparison with a piston manometer"],"techniques_zh":["与活塞式压力计比较"],"techniques_cs":["Porovnání s pístovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nciśnienie względne; ciecz od 0 kPa do 0,6 MPa CMC 0,18 kPa\nciśnienie względne; ciecz od 0,6 MPa do 60 MPa CMC 0,03 %\nciśnienie bezwzględne; ciecz od 0,1 MPa do 0,7 MPa CMC 0,28 kPa\nciśnienie bezwzględne; ciecz od 14 MPa do 60 MPa CMC 0,03 % + 0,1 kPa\nPorównanie z manometrem tłokowym","reference":"KL-PM-0101","norm_bases":["KL-PM-0101"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z manometrem tłokowym ciśnienie względne; ciecz od 0 kPa do 0,6 MPa CMC 0,18 kPa ciśnienie względne; ciecz od 0,6 MPa do 60 MPa CMC 0,03 % ciśnienie bezwzględne; ciecz od 0,1 MPa do 0,7 MPa CMC 0,28 kPa ciśnienie bezwzględne; ciecz od 14 MPa do 60 MPa CMC 0,03 % + 0,1 kPa Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku Kalibrace – tlak Porovnání s pístovým tlakoměrem tlak relativní; kapalina 0 kPa až 0,6 MPa CMC 0,18 kPa tlak relativní; kapalina 0,6 MPa až 60 MPa CMC 0,03 % tlak absolutní; kapalina 0,1 MPa až 0,7 MPa CMC 0,28 kPa tlak absolutní; kapalina 14 MPa až 60 MPa CMC 0,03 % + 0,1 kPa KL-PM-0101 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia i tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z manometrem tlokowym cisnienie wzgledne; ciecz od 0 kPa do 0,6 MPa CMC 0,18 kPa cisnienie wzgledne; ciecz od 0,6 MPa do 60 MPa CMC 0,03 % cisnienie bezwzgledne; ciecz od 0,1 MPa do 0,7 MPa CMC 0,28 kPa cisnienie bezwzgledne; ciecz od 14 MPa do 60 MPa CMC 0,03 % + 0,1 kPa Deformacni a cislicove tlakomery, prevodniky tlaku a merici retezce tlaku Kalibrace – tlak Porovnani s pistovym tlakomerem tlak relativni; kapalina 0 kPa az 0,6 MPa CMC 0,18 kPa tlak relativni; kapalina 0,6 MPa az 60 MPa CMC 0,03 % tlak absolutni; kapalina 0,1 MPa az 0,7 MPa CMC 0,28 kPa tlak absolutni; kapalina 14 MPa az 60 MPa CMC 0,03 % + 0,1 kPa KL-PM-0101","search_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains Calibration – pressure Comparison with a piston manometer relative pressure; liquid 0 kPa to 0,6 MPa CMC 0,18 kPa relative pressure; liquid 0,6 MPa to 60 MPa CMC 0,03 % absolute pressure; liquid 0,1 MPa to 0,7 MPa CMC 0,28 kPa absolute pressure; liquid 14 MPa to 60 MPa CMC 0,03 % + 0,1 kPa KL-PM-0101","search_zh":"弹性式和数字式压力表、压力变送器和压力测量链 校准 – 压力 与活塞式压力计比较 相对压力；液体 0 kPa 至 0,6 MPa CMC 0,18 kPa 相对压力；液体 0,6 MPa 至 60 MPa CMC 0,03 % 绝对压力；液体 0,1 MPa 至 0,7 MPa CMC 0,28 kPa 绝对压力；液体 14 MPa 至 60 MPa CMC 0,03 % + 0,1 kPa KL-PM-0101","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75e37b25b2ed7d037d261458","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器和压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"ciśnienie względne; ciecz","range":"od 0 kPa do 0,6 MPa","cmc":"0,18 kPa"},{"name":"ciśnienie względne; ciecz","range":"od 0,6 MPa do 60 MPa","cmc":"0,03 %"},{"name":"ciśnienie bezwzględne; ciecz","range":"od 0,1 MPa do 0,7 MPa","cmc":"0,28 kPa"},{"name":"ciśnienie bezwzględne; ciecz","range":"od 14 MPa do 60 MPa","cmc":"0,03 % + 0,1 kPa"}],"parameters_en":[{"name":"relative pressure; liquid","range":"0 kPa to 0,6 MPa","cmc":"0,18 kPa"},{"name":"relative pressure; liquid","range":"0,6 MPa to 60 MPa","cmc":"0,03 %"},{"name":"absolute pressure; liquid","range":"0,1 MPa to 0,7 MPa","cmc":"0,28 kPa"},{"name":"absolute pressure; liquid","range":"14 MPa to 60 MPa","cmc":"0,03 % + 0,1 kPa"}],"parameters_zh":[{"name":"相对压力；液体","range":"0 kPa 至 0,6 MPa","cmc":"0,18 kPa"},{"name":"相对压力；液体","range":"0,6 MPa 至 60 MPa","cmc":"0,03 %"},{"name":"绝对压力；液体","range":"0,1 MPa 至 0,7 MPa","cmc":"0,28 kPa"},{"name":"绝对压力；液体","range":"14 MPa 至 60 MPa","cmc":"0,03 % + 0,1 kPa"}],"parameters_cs":[{"name":"tlak relativní; kapalina","range":"0 kPa až 0,6 MPa","cmc":"0,18 kPa"},{"name":"tlak relativní; kapalina","range":"0,6 MPa až 60 MPa","cmc":"0,03 %"},{"name":"tlak absolutní; kapalina","range":"0,1 MPa až 0,7 MPa","cmc":"0,28 kPa"},{"name":"tlak absolutní; kapalina","range":"14 MPa až 60 MPa","cmc":"0,03 % + 0,1 kPa"}],"technique":"Porównanie z manometrem tłokowym","technique_en":"Comparison with a piston manometer","technique_zh":"与活塞式压力计比较","technique_cs":"Porovnání s pístovým tlakoměrem","techniques":["Porównanie z manometrem tłokowym"],"techniques_en":["Comparison with a piston manometer"],"techniques_zh":["与活塞式压力计比较"],"techniques_cs":["Porovnání s pístovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nciśnienie względne; ciecz od 0 kPa do 0,6 MPa CMC 0,18 kPa\nciśnienie względne; ciecz od 0,6 MPa do 60 MPa CMC 0,03 %\nciśnienie bezwzględne; ciecz od 0,1 MPa do 0,7 MPa CMC 0,28 kPa\nciśnienie bezwzględne; ciecz od 14 MPa do 60 MPa CMC 0,03 % + 0,1 kPa\nPorównanie z manometrem tłokowym","reference":"KL-PM-0101","norm_bases":["KL-PM-0101"],"lab_section":"Pracownia Pardubice","lab_section_en":"Workplace Pardubice","lab_section_zh":"Pardubice 工作场所","lab_section_cs":"Pracoviště Pardubice","lab_address":"budova M 84, Semtín 103, 530 02 Pardubice","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z manometrem tłokowym ciśnienie względne; ciecz od 0 kPa do 0,6 MPa CMC 0,18 kPa ciśnienie względne; ciecz od 0,6 MPa do 60 MPa CMC 0,03 % ciśnienie bezwzględne; ciecz od 0,1 MPa do 0,7 MPa CMC 0,28 kPa ciśnienie bezwzględne; ciecz od 14 MPa do 60 MPa CMC 0,03 % + 0,1 kPa Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku Kalibrace – tlak Porovnání s pístovým tlakoměrem tlak relativní; kapalina 0 kPa až 0,6 MPa CMC 0,18 kPa tlak relativní; kapalina 0,6 MPa až 60 MPa CMC 0,03 % tlak absolutní; kapalina 0,1 MPa až 0,7 MPa CMC 0,28 kPa tlak absolutní; kapalina 14 MPa až 60 MPa CMC 0,03 % + 0,1 kPa KL-PM-0101 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia i tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z manometrem tlokowym cisnienie wzgledne; ciecz od 0 kPa do 0,6 MPa CMC 0,18 kPa cisnienie wzgledne; ciecz od 0,6 MPa do 60 MPa CMC 0,03 % cisnienie bezwzgledne; ciecz od 0,1 MPa do 0,7 MPa CMC 0,28 kPa cisnienie bezwzgledne; ciecz od 14 MPa do 60 MPa CMC 0,03 % + 0,1 kPa Deformacni a cislicove tlakomery, prevodniky tlaku a merici retezce tlaku Kalibrace – tlak Porovnani s pistovym tlakomerem tlak relativni; kapalina 0 kPa az 0,6 MPa CMC 0,18 kPa tlak relativni; kapalina 0,6 MPa az 60 MPa CMC 0,03 % tlak absolutni; kapalina 0,1 MPa az 0,7 MPa CMC 0,28 kPa tlak absolutni; kapalina 14 MPa az 60 MPa CMC 0,03 % + 0,1 kPa KL-PM-0101","search_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains Calibration – pressure Comparison with a piston manometer relative pressure; liquid 0 kPa to 0,6 MPa CMC 0,18 kPa relative pressure; liquid 0,6 MPa to 60 MPa CMC 0,03 % absolute pressure; liquid 0,1 MPa to 0,7 MPa CMC 0,28 kPa absolute pressure; liquid 14 MPa to 60 MPa CMC 0,03 % + 0,1 kPa KL-PM-0101","search_zh":"弹性式和数字式压力表、压力变送器和压力测量链 校准 – 压力 与活塞式压力计比较 相对压力；液体 0 kPa 至 0,6 MPa CMC 0,18 kPa 相对压力；液体 0,6 MPa 至 60 MPa CMC 0,03 % 绝对压力；液体 0,1 MPa 至 0,7 MPa CMC 0,28 kPa 绝对压力；液体 14 MPa 至 60 MPa CMC 0,03 % + 0,1 kPa KL-PM-0101","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6a8ecf62459aa1450c1a8b8e","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器和压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"ciśnienie względne; ciecz","range":"od 60 MPa do 70 MPa","cmc":"0,1 %"},{"name":"ciśnienie bezwzględne; ciecz","range":"od 60 MPa do 70 MPa","cmc":"0,10 % + 0,1 kPa"}],"parameters_en":[{"name":"relative pressure; liquid","range":"60 MPa to 70 MPa","cmc":"0,1 %"},{"name":"absolute pressure; liquid","range":"60 MPa to 70 MPa","cmc":"0,10 % + 0,1 kPa"}],"parameters_zh":[{"name":"相对压力；液体","range":"60 MPa 至 70 MPa","cmc":"0,1 %"},{"name":"绝对压力；液体","range":"60 MPa 至 70 MPa","cmc":"0,10 % + 0,1 kPa"}],"parameters_cs":[{"name":"tlak relativní; kapalina","range":"60 MPa až 70 MPa","cmc":"0,1 %"},{"name":"tlak absolutní; kapalina","range":"60 MPa až 70 MPa","cmc":"0,10 % + 0,1 kPa"}],"technique":"Porównanie z ciśnieniomierzem cyfrowym","technique_en":"Comparison with a digital manometer","technique_zh":"与数字压力表比较","technique_cs":"Porovnání s číslicovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a digital manometer"],"techniques_zh":["与数字压力表比较"],"techniques_cs":["Porovnání s číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nciśnienie względne; ciecz od 60 MPa do 70 MPa CMC 0,1 %\nciśnienie bezwzględne; ciecz od 60 MPa do 70 MPa CMC 0,10 % + 0,1 kPa\nPorównanie z ciśnieniomierzem cyfrowym","reference":"KL-PM-0101","norm_bases":["KL-PM-0101"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z ciśnieniomierzem cyfrowym ciśnienie względne; ciecz od 60 MPa do 70 MPa CMC 0,1 % ciśnienie bezwzględne; ciecz od 60 MPa do 70 MPa CMC 0,10 % + 0,1 kPa Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku Kalibrace – tlak Porovnání s číslicovým tlakoměrem tlak relativní; kapalina 60 MPa až 70 MPa CMC 0,1 % tlak absolutní; kapalina 60 MPa až 70 MPa CMC 0,10 % + 0,1 kPa KL-PM-0101 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia i tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z cisnieniomierzem cyfrowym cisnienie wzgledne; ciecz od 60 MPa do 70 MPa CMC 0,1 % cisnienie bezwzgledne; ciecz od 60 MPa do 70 MPa CMC 0,10 % + 0,1 kPa Deformacni a cislicove tlakomery, prevodniky tlaku a merici retezce tlaku Kalibrace – tlak Porovnani s cislicovym tlakomerem tlak relativni; kapalina 60 MPa az 70 MPa CMC 0,1 % tlak absolutni; kapalina 60 MPa az 70 MPa CMC 0,10 % + 0,1 kPa KL-PM-0101","search_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains Calibration – pressure Comparison with a digital manometer relative pressure; liquid 60 MPa to 70 MPa CMC 0,1 % absolute pressure; liquid 60 MPa to 70 MPa CMC 0,10 % + 0,1 kPa KL-PM-0101","search_zh":"弹性式和数字式压力表、压力变送器和压力测量链 校准 – 压力 与数字压力表比较 相对压力；液体 60 MPa 至 70 MPa CMC 0,1 % 绝对压力；液体 60 MPa 至 70 MPa CMC 0,10 % + 0,1 kPa KL-PM-0101","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eebc9687d8bce24bbe9fb14e","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器和压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"ciśnienie względne; ciecz","range":"od 60 MPa do 70 MPa","cmc":"0,1 %"},{"name":"ciśnienie bezwzględne; ciecz","range":"od 60 MPa do 70 MPa","cmc":"0,10 % + 0,1 kPa"}],"parameters_en":[{"name":"relative pressure; liquid","range":"60 MPa to 70 MPa","cmc":"0,1 %"},{"name":"absolute pressure; liquid","range":"60 MPa to 70 MPa","cmc":"0,10 % + 0,1 kPa"}],"parameters_zh":[{"name":"相对压力；液体","range":"60 MPa 至 70 MPa","cmc":"0,1 %"},{"name":"绝对压力；液体","range":"60 MPa 至 70 MPa","cmc":"0,10 % + 0,1 kPa"}],"parameters_cs":[{"name":"tlak relativní; kapalina","range":"60 MPa až 70 MPa","cmc":"0,1 %"},{"name":"tlak absolutní; kapalina","range":"60 MPa až 70 MPa","cmc":"0,10 % + 0,1 kPa"}],"technique":"Porównanie z ciśnieniomierzem cyfrowym","technique_en":"Comparison with a digital manometer","technique_zh":"与数字压力表比较","technique_cs":"Porovnání s číslicovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a digital manometer"],"techniques_zh":["与数字压力表比较"],"techniques_cs":["Porovnání s číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nciśnienie względne; ciecz od 60 MPa do 70 MPa CMC 0,1 %\nciśnienie bezwzględne; ciecz od 60 MPa do 70 MPa CMC 0,10 % + 0,1 kPa\nPorównanie z ciśnieniomierzem cyfrowym","reference":"KL-PM-0101","norm_bases":["KL-PM-0101"],"lab_section":"Pracownia Pardubice","lab_section_en":"Workplace Pardubice","lab_section_zh":"Pardubice 工作场所","lab_section_cs":"Pracoviště Pardubice","lab_address":"budova M 84, Semtín 103, 530 02 Pardubice","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z ciśnieniomierzem cyfrowym ciśnienie względne; ciecz od 60 MPa do 70 MPa CMC 0,1 % ciśnienie bezwzględne; ciecz od 60 MPa do 70 MPa CMC 0,10 % + 0,1 kPa Deformační a číslicové tlakoměry, převodníky tlaku a měřicí řetězce tlaku Kalibrace – tlak Porovnání s číslicovým tlakoměrem tlak relativní; kapalina 60 MPa až 70 MPa CMC 0,1 % tlak absolutní; kapalina 60 MPa až 70 MPa CMC 0,10 % + 0,1 kPa KL-PM-0101 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia i tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z cisnieniomierzem cyfrowym cisnienie wzgledne; ciecz od 60 MPa do 70 MPa CMC 0,1 % cisnienie bezwzgledne; ciecz od 60 MPa do 70 MPa CMC 0,10 % + 0,1 kPa Deformacni a cislicove tlakomery, prevodniky tlaku a merici retezce tlaku Kalibrace – tlak Porovnani s cislicovym tlakomerem tlak relativni; kapalina 60 MPa az 70 MPa CMC 0,1 % tlak absolutni; kapalina 60 MPa az 70 MPa CMC 0,10 % + 0,1 kPa KL-PM-0101","search_en":"Deformation and digital manometers, pressure transducers and pressure measuring chains Calibration – pressure Comparison with a digital manometer relative pressure; liquid 60 MPa to 70 MPa CMC 0,1 % absolute pressure; liquid 60 MPa to 70 MPa CMC 0,10 % + 0,1 kPa KL-PM-0101","search_zh":"弹性式和数字式压力表、压力变送器和压力测量链 校准 – 压力 与数字压力表比较 相对压力；液体 60 MPa 至 70 MPa CMC 0,1 % 绝对压力；液体 60 MPa 至 70 MPa CMC 0,10 % + 0,1 kPa KL-PM-0101","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d08c27dd490f8119b3ba01ce","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Rezystancyjne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z rezystancyjnymi czujnikami temperatury","test_object_en":"Resistance temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with resistance temperature sensors","test_object_zh":"电阻温度传感器（不带/带变送器）、直读式温度计和带电阻温度传感器的测量链","test_object_cs":"Odporové snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s odporovými snímači teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"-196 °C","cmc":"0,15 °C"},{"name":"","range":"od -196 °C do -40 °C","cmc":"0,20 °C"},{"name":"","range":"od -40 °C do 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C","cmc":"0,04 °C"},{"name":"","range":"od 0 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"od 100 °C do 200 °C","cmc":"0,06 °C"},{"name":"","range":"od 200 °C do 300 °C","cmc":"0,15 °C"},{"name":"","range":"od 300 °C do 420 °C","cmc":"0,18 °C"},{"name":"","range":"od 420 °C do 660 °C","cmc":"0,23 °C"}],"parameters_en":[{"name":"","range":"-196 °C","cmc":"0,15 °C"},{"name":"","range":"-196 °C to -40 °C","cmc":"0,20 °C"},{"name":"","range":"-40 °C to 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C to 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C to 300 °C","cmc":"0,15 °C"},{"name":"","range":"300 °C to 420 °C","cmc":"0,18 °C"},{"name":"","range":"420 °C to 660 °C","cmc":"0,23 °C"}],"parameters_zh":[{"name":"","range":"-196 °C","cmc":"0,15 °C"},{"name":"","range":"-196 °C 至 -40 °C","cmc":"0,20 °C"},{"name":"","range":"-40 °C 至 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C 至 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C 至 300 °C","cmc":"0,15 °C"},{"name":"","range":"300 °C 至 420 °C","cmc":"0,18 °C"},{"name":"","range":"420 °C 至 660 °C","cmc":"0,23 °C"}],"parameters_cs":[{"name":"","range":"-196 °C","cmc":"0,15 °C"},{"name":"","range":"-196 °C až -40 °C","cmc":"0,20 °C"},{"name":"","range":"-40 °C až 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C až 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C až 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C až 300 °C","cmc":"0,15 °C"},{"name":"","range":"300 °C až 420 °C","cmc":"0,18 °C"},{"name":"","range":"420 °C až 660 °C","cmc":"0,23 °C"}],"technique":"Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych","technique_en":"Comparison with a Pt100 standard in liquid baths and dry block calibrators","technique_zh":"在液体槽或干井炉中与 Pt100 标准比较","technique_cs":"Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách","techniques":["Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych"],"techniques_en":["Comparison with a Pt100 standard in liquid baths and dry block calibrators"],"techniques_zh":["在液体槽或干井炉中与 Pt100 标准比较"],"techniques_cs":["Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\n-196 °C CMC 0,15 °C\nod -196 °C do -40 °C CMC 0,20 °C\nod -40 °C do 0 °C CMC 0,05 °C\n0 °C CMC 0,04 °C\nod 0 °C do 100 °C CMC 0,05 °C\nod 100 °C do 200 °C CMC 0,06 °C\nod 200 °C do 300 °C CMC 0,15 °C\nod 300 °C do 420 °C CMC 0,18 °C\nod 420 °C do 660 °C CMC 0,23 °C\nPorównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych","reference":"KL-PM-0001","norm_bases":["KL-PM-0001"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z rezystancyjnymi czujnikami temperatury Wzorcowanie – temperatura Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych -196 °C CMC 0,15 °C od -196 °C do -40 °C CMC 0,20 °C od -40 °C do 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C od 0 °C do 100 °C CMC 0,05 °C od 100 °C do 200 °C CMC 0,06 °C od 200 °C do 300 °C CMC 0,15 °C od 300 °C do 420 °C CMC 0,18 °C od 420 °C do 660 °C CMC 0,23 °C Odporové snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s odporovými snímači teploty Kalibrace – teplota Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách -196 °C CMC 0,15 °C -196 °C až -40 °C CMC 0,20 °C -40 °C až 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C 0 °C až 100 °C CMC 0,05 °C 100 °C až 200 °C CMC 0,06 °C 200 °C až 300 °C CMC 0,15 °C 300 °C až 420 °C CMC 0,18 °C 420 °C až 660 °C CMC 0,23 °C KL-PM-0001 Rezystancyjne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezposrednio wskazujace i tory pomiarowe z rezystancyjnymi czujnikami temperatury Wzorcowanie – temperatura Porownanie z wzorcem Pt100 w lazniach cieczowych lub piecykach blokowych -196 °C CMC 0,15 °C od -196 °C do -40 °C CMC 0,20 °C od -40 °C do 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C od 0 °C do 100 °C CMC 0,05 °C od 100 °C do 200 °C CMC 0,06 °C od 200 °C do 300 °C CMC 0,15 °C od 300 °C do 420 °C CMC 0,18 °C od 420 °C do 660 °C CMC 0,23 °C Odporove snimace teploty (bez prevodniku/s prevodnikem), primoukazujici teplomery a merici retezce s odporovymi snimaci teploty Kalibrace – teplota Porovnani s etalonem Pt100 v kapalinovych laznich nebo blokovych pickach -196 °C CMC 0,15 °C -196 °C az -40 °C CMC 0,20 °C -40 °C az 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C 0 °C az 100 °C CMC 0,05 °C 100 °C az 200 °C CMC 0,06 °C 200 °C az 300 °C CMC 0,15 °C 300 °C az 420 °C CMC 0,18 °C 420 °C az 660 °C CMC 0,23 °C KL-PM-0001","search_en":"Resistance temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with resistance temperature sensors Calibration – temperature Comparison with a Pt100 standard in liquid baths and dry block calibrators -196 °C CMC 0,15 °C -196 °C to -40 °C CMC 0,20 °C -40 °C to 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C 0 °C to 100 °C CMC 0,05 °C 100 °C to 200 °C CMC 0,06 °C 200 °C to 300 °C CMC 0,15 °C 300 °C to 420 °C CMC 0,18 °C 420 °C to 660 °C CMC 0,23 °C KL-PM-0001","search_zh":"电阻温度传感器（不带/带变送器）、直读式温度计和带电阻温度传感器的测量链 校准 – 温度 在液体槽或干井炉中与 Pt100 标准比较 -196 °C CMC 0,15 °C -196 °C 至 -40 °C CMC 0,20 °C -40 °C 至 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C 0 °C 至 100 °C CMC 0,05 °C 100 °C 至 200 °C CMC 0,06 °C 200 °C 至 300 °C CMC 0,15 °C 300 °C 至 420 °C CMC 0,18 °C 420 °C 至 660 °C CMC 0,23 °C KL-PM-0001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f7bde425f0891f77839a093","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Rezystancyjne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z rezystancyjnymi czujnikami temperatury","test_object_en":"Resistance temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with resistance temperature sensors","test_object_zh":"电阻温度传感器（不带/带变送器）、直读式温度计和带电阻温度传感器的测量链","test_object_cs":"Odporové snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s odporovými snímači teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"-196 °C","cmc":"0,15 °C"},{"name":"","range":"od -196 °C do -40 °C","cmc":"0,20 °C"},{"name":"","range":"od -40 °C do 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C","cmc":"0,04 °C"},{"name":"","range":"od 0 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"od 100 °C do 200 °C","cmc":"0,06 °C"},{"name":"","range":"od 200 °C do 300 °C","cmc":"0,15 °C"},{"name":"","range":"od 300 °C do 420 °C","cmc":"0,18 °C"},{"name":"","range":"od 420 °C do 660 °C","cmc":"0,23 °C"}],"parameters_en":[{"name":"","range":"-196 °C","cmc":"0,15 °C"},{"name":"","range":"-196 °C to -40 °C","cmc":"0,20 °C"},{"name":"","range":"-40 °C to 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C to 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C to 300 °C","cmc":"0,15 °C"},{"name":"","range":"300 °C to 420 °C","cmc":"0,18 °C"},{"name":"","range":"420 °C to 660 °C","cmc":"0,23 °C"}],"parameters_zh":[{"name":"","range":"-196 °C","cmc":"0,15 °C"},{"name":"","range":"-196 °C 至 -40 °C","cmc":"0,20 °C"},{"name":"","range":"-40 °C 至 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C 至 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C 至 300 °C","cmc":"0,15 °C"},{"name":"","range":"300 °C 至 420 °C","cmc":"0,18 °C"},{"name":"","range":"420 °C 至 660 °C","cmc":"0,23 °C"}],"parameters_cs":[{"name":"","range":"-196 °C","cmc":"0,15 °C"},{"name":"","range":"-196 °C až -40 °C","cmc":"0,20 °C"},{"name":"","range":"-40 °C až 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C až 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C až 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C až 300 °C","cmc":"0,15 °C"},{"name":"","range":"300 °C až 420 °C","cmc":"0,18 °C"},{"name":"","range":"420 °C až 660 °C","cmc":"0,23 °C"}],"technique":"Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych","technique_en":"Comparison with a Pt100 standard in liquid baths and dry block calibrators","technique_zh":"在液体槽或干井炉中与 Pt100 标准比较","technique_cs":"Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách","techniques":["Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych"],"techniques_en":["Comparison with a Pt100 standard in liquid baths and dry block calibrators"],"techniques_zh":["在液体槽或干井炉中与 Pt100 标准比较"],"techniques_cs":["Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\n-196 °C CMC 0,15 °C\nod -196 °C do -40 °C CMC 0,20 °C\nod -40 °C do 0 °C CMC 0,05 °C\n0 °C CMC 0,04 °C\nod 0 °C do 100 °C CMC 0,05 °C\nod 100 °C do 200 °C CMC 0,06 °C\nod 200 °C do 300 °C CMC 0,15 °C\nod 300 °C do 420 °C CMC 0,18 °C\nod 420 °C do 660 °C CMC 0,23 °C\nPorównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych","reference":"KL-PM-0001","norm_bases":["KL-PM-0001"],"lab_section":"Pracownia Pardubice","lab_section_en":"Workplace Pardubice","lab_section_zh":"Pardubice 工作场所","lab_section_cs":"Pracoviště Pardubice","lab_address":"budova M 84, Semtín 103, 530 02 Pardubice","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z rezystancyjnymi czujnikami temperatury Wzorcowanie – temperatura Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych -196 °C CMC 0,15 °C od -196 °C do -40 °C CMC 0,20 °C od -40 °C do 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C od 0 °C do 100 °C CMC 0,05 °C od 100 °C do 200 °C CMC 0,06 °C od 200 °C do 300 °C CMC 0,15 °C od 300 °C do 420 °C CMC 0,18 °C od 420 °C do 660 °C CMC 0,23 °C Odporové snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s odporovými snímači teploty Kalibrace – teplota Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách -196 °C CMC 0,15 °C -196 °C až -40 °C CMC 0,20 °C -40 °C až 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C 0 °C až 100 °C CMC 0,05 °C 100 °C až 200 °C CMC 0,06 °C 200 °C až 300 °C CMC 0,15 °C 300 °C až 420 °C CMC 0,18 °C 420 °C až 660 °C CMC 0,23 °C KL-PM-0001 Rezystancyjne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezposrednio wskazujace i tory pomiarowe z rezystancyjnymi czujnikami temperatury Wzorcowanie – temperatura Porownanie z wzorcem Pt100 w lazniach cieczowych lub piecykach blokowych -196 °C CMC 0,15 °C od -196 °C do -40 °C CMC 0,20 °C od -40 °C do 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C od 0 °C do 100 °C CMC 0,05 °C od 100 °C do 200 °C CMC 0,06 °C od 200 °C do 300 °C CMC 0,15 °C od 300 °C do 420 °C CMC 0,18 °C od 420 °C do 660 °C CMC 0,23 °C Odporove snimace teploty (bez prevodniku/s prevodnikem), primoukazujici teplomery a merici retezce s odporovymi snimaci teploty Kalibrace – teplota Porovnani s etalonem Pt100 v kapalinovych laznich nebo blokovych pickach -196 °C CMC 0,15 °C -196 °C az -40 °C CMC 0,20 °C -40 °C az 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C 0 °C az 100 °C CMC 0,05 °C 100 °C az 200 °C CMC 0,06 °C 200 °C az 300 °C CMC 0,15 °C 300 °C az 420 °C CMC 0,18 °C 420 °C az 660 °C CMC 0,23 °C KL-PM-0001","search_en":"Resistance temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with resistance temperature sensors Calibration – temperature Comparison with a Pt100 standard in liquid baths and dry block calibrators -196 °C CMC 0,15 °C -196 °C to -40 °C CMC 0,20 °C -40 °C to 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C 0 °C to 100 °C CMC 0,05 °C 100 °C to 200 °C CMC 0,06 °C 200 °C to 300 °C CMC 0,15 °C 300 °C to 420 °C CMC 0,18 °C 420 °C to 660 °C CMC 0,23 °C KL-PM-0001","search_zh":"电阻温度传感器（不带/带变送器）、直读式温度计和带电阻温度传感器的测量链 校准 – 温度 在液体槽或干井炉中与 Pt100 标准比较 -196 °C CMC 0,15 °C -196 °C 至 -40 °C CMC 0,20 °C -40 °C 至 0 °C CMC 0,05 °C 0 °C CMC 0,04 °C 0 °C 至 100 °C CMC 0,05 °C 100 °C 至 200 °C CMC 0,06 °C 200 °C 至 300 °C CMC 0,15 °C 300 °C 至 420 °C CMC 0,18 °C 420 °C 至 660 °C CMC 0,23 °C KL-PM-0001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9861ed5d35db6788414a5b89","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z termoparami","test_object_en":"Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples","test_object_zh":"热电温度传感器（不带/带变送器）、直读式温度计和带热电偶的测量链","test_object_cs":"Termoelektrické snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s termoelektrickými články","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -196 °C do -40 °C","cmc":"0,6 °C"},{"name":"","range":"od -40 °C do 200 °C","cmc":"0,3 °C"},{"name":"","range":"od 200 °C do 400 °C","cmc":"0,6 °C"},{"name":"","range":"od 400 °C do 660 °C","cmc":"0,9 °C"}],"parameters_en":[{"name":"","range":"-196 °C to -40 °C","cmc":"0,6 °C"},{"name":"","range":"-40 °C to 200 °C","cmc":"0,3 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"0,6 °C"},{"name":"","range":"400 °C to 660 °C","cmc":"0,9 °C"}],"parameters_zh":[{"name":"","range":"-196 °C 至 -40 °C","cmc":"0,6 °C"},{"name":"","range":"-40 °C 至 200 °C","cmc":"0,3 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"0,6 °C"},{"name":"","range":"400 °C 至 660 °C","cmc":"0,9 °C"}],"parameters_cs":[{"name":"","range":"-196 °C až -40 °C","cmc":"0,6 °C"},{"name":"","range":"-40 °C až 200 °C","cmc":"0,3 °C"},{"name":"","range":"200 °C až 400 °C","cmc":"0,6 °C"},{"name":"","range":"400 °C až 660 °C","cmc":"0,9 °C"}],"technique":"Porównanie z wzorcem Pt100 w łaźniach cieczowych, piecykach blokowych","technique_en":"Comparison with a Pt100 standard in liquid baths and dry block calibrators","technique_zh":"在液体槽、干井炉中与 Pt100 标准比较","technique_cs":"Porovnání s etalonem Pt100 v kapalinových lázních, blokových píckách","techniques":["Porównanie z wzorcem Pt100 w łaźniach cieczowych, piecykach blokowych"],"techniques_en":["Comparison with a Pt100 standard in liquid baths and dry block calibrators"],"techniques_zh":["在液体槽、干井炉中与 Pt100 标准比较"],"techniques_cs":["Porovnání s etalonem Pt100 v kapalinových lázních, blokových píckách"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -196 °C do -40 °C CMC 0,6 °C\nod -40 °C do 200 °C CMC 0,3 °C\nod 200 °C do 400 °C CMC 0,6 °C\nod 400 °C do 660 °C CMC 0,9 °C\nPorównanie z wzorcem Pt100 w łaźniach cieczowych, piecykach blokowych","reference":"KL-PM-0002","norm_bases":["KL-PM-0002"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z termoparami Wzorcowanie – temperatura Porównanie z wzorcem Pt100 w łaźniach cieczowych, piecykach blokowych od -196 °C do -40 °C CMC 0,6 °C od -40 °C do 200 °C CMC 0,3 °C od 200 °C do 400 °C CMC 0,6 °C od 400 °C do 660 °C CMC 0,9 °C Termoelektrické snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s termoelektrickými články Kalibrace – teplota Porovnání s etalonem Pt100 v kapalinových lázních, blokových píckách -196 °C až -40 °C CMC 0,6 °C -40 °C až 200 °C CMC 0,3 °C 200 °C až 400 °C CMC 0,6 °C 400 °C až 660 °C CMC 0,9 °C KL-PM-0002 Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezposrednio wskazujace i tory pomiarowe z termoparami Wzorcowanie – temperatura Porownanie z wzorcem Pt100 w lazniach cieczowych, piecykach blokowych od -196 °C do -40 °C CMC 0,6 °C od -40 °C do 200 °C CMC 0,3 °C od 200 °C do 400 °C CMC 0,6 °C od 400 °C do 660 °C CMC 0,9 °C Termoelektricke snimace teploty (bez prevodniku/s prevodnikem), primoukazujici teplomery a merici retezce s termoelektrickymi clanky Kalibrace – teplota Porovnani s etalonem Pt100 v kapalinovych laznich, blokovych pickach -196 °C az -40 °C CMC 0,6 °C -40 °C az 200 °C CMC 0,3 °C 200 °C az 400 °C CMC 0,6 °C 400 °C az 660 °C CMC 0,9 °C KL-PM-0002","search_en":"Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples Calibration – temperature Comparison with a Pt100 standard in liquid baths and dry block calibrators -196 °C to -40 °C CMC 0,6 °C -40 °C to 200 °C CMC 0,3 °C 200 °C to 400 °C CMC 0,6 °C 400 °C to 660 °C CMC 0,9 °C KL-PM-0002","search_zh":"热电温度传感器（不带/带变送器）、直读式温度计和带热电偶的测量链 校准 – 温度 在液体槽、干井炉中与 Pt100 标准比较 -196 °C 至 -40 °C CMC 0,6 °C -40 °C 至 200 °C CMC 0,3 °C 200 °C 至 400 °C CMC 0,6 °C 400 °C 至 660 °C CMC 0,9 °C KL-PM-0002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"79831ec7106961ed0bce390c","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z termoparami","test_object_en":"Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples","test_object_zh":"热电温度传感器（不带/带变送器）、直读式温度计和带热电偶的测量链","test_object_cs":"Termoelektrické snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s termoelektrickými články","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -196 °C do -40 °C","cmc":"0,6 °C"},{"name":"","range":"od -40 °C do 200 °C","cmc":"0,3 °C"},{"name":"","range":"od 200 °C do 400 °C","cmc":"0,6 °C"},{"name":"","range":"od 400 °C do 660 °C","cmc":"0,9 °C"}],"parameters_en":[{"name":"","range":"-196 °C to -40 °C","cmc":"0,6 °C"},{"name":"","range":"-40 °C to 200 °C","cmc":"0,3 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"0,6 °C"},{"name":"","range":"400 °C to 660 °C","cmc":"0,9 °C"}],"parameters_zh":[{"name":"","range":"-196 °C 至 -40 °C","cmc":"0,6 °C"},{"name":"","range":"-40 °C 至 200 °C","cmc":"0,3 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"0,6 °C"},{"name":"","range":"400 °C 至 660 °C","cmc":"0,9 °C"}],"parameters_cs":[{"name":"","range":"-196 °C až -40 °C","cmc":"0,6 °C"},{"name":"","range":"-40 °C až 200 °C","cmc":"0,3 °C"},{"name":"","range":"200 °C až 400 °C","cmc":"0,6 °C"},{"name":"","range":"400 °C až 660 °C","cmc":"0,9 °C"}],"technique":"Porównanie z wzorcem Pt100 w łaźniach cieczowych, piecykach blokowych","technique_en":"Comparison with a Pt100 standard in liquid baths and dry block calibrators","technique_zh":"在液体槽、干井炉中与 Pt100 标准比较","technique_cs":"Porovnání s etalonem Pt100 v kapalinových lázních, blokových píckách","techniques":["Porównanie z wzorcem Pt100 w łaźniach cieczowych, piecykach blokowych"],"techniques_en":["Comparison with a Pt100 standard in liquid baths and dry block calibrators"],"techniques_zh":["在液体槽、干井炉中与 Pt100 标准比较"],"techniques_cs":["Porovnání s etalonem Pt100 v kapalinových lázních, blokových píckách"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -196 °C do -40 °C CMC 0,6 °C\nod -40 °C do 200 °C CMC 0,3 °C\nod 200 °C do 400 °C CMC 0,6 °C\nod 400 °C do 660 °C CMC 0,9 °C\nPorównanie z wzorcem Pt100 w łaźniach cieczowych, piecykach blokowych","reference":"KL-PM-0002","norm_bases":["KL-PM-0002"],"lab_section":"Pracownia Pardubice","lab_section_en":"Workplace Pardubice","lab_section_zh":"Pardubice 工作场所","lab_section_cs":"Pracoviště Pardubice","lab_address":"budova M 84, Semtín 103, 530 02 Pardubice","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z termoparami Wzorcowanie – temperatura Porównanie z wzorcem Pt100 w łaźniach cieczowych, piecykach blokowych od -196 °C do -40 °C CMC 0,6 °C od -40 °C do 200 °C CMC 0,3 °C od 200 °C do 400 °C CMC 0,6 °C od 400 °C do 660 °C CMC 0,9 °C Termoelektrické snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s termoelektrickými články Kalibrace – teplota Porovnání s etalonem Pt100 v kapalinových lázních, blokových píckách -196 °C až -40 °C CMC 0,6 °C -40 °C až 200 °C CMC 0,3 °C 200 °C až 400 °C CMC 0,6 °C 400 °C až 660 °C CMC 0,9 °C KL-PM-0002 Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezposrednio wskazujace i tory pomiarowe z termoparami Wzorcowanie – temperatura Porownanie z wzorcem Pt100 w lazniach cieczowych, piecykach blokowych od -196 °C do -40 °C CMC 0,6 °C od -40 °C do 200 °C CMC 0,3 °C od 200 °C do 400 °C CMC 0,6 °C od 400 °C do 660 °C CMC 0,9 °C Termoelektricke snimace teploty (bez prevodniku/s prevodnikem), primoukazujici teplomery a merici retezce s termoelektrickymi clanky Kalibrace – teplota Porovnani s etalonem Pt100 v kapalinovych laznich, blokovych pickach -196 °C az -40 °C CMC 0,6 °C -40 °C az 200 °C CMC 0,3 °C 200 °C az 400 °C CMC 0,6 °C 400 °C az 660 °C CMC 0,9 °C KL-PM-0002","search_en":"Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples Calibration – temperature Comparison with a Pt100 standard in liquid baths and dry block calibrators -196 °C to -40 °C CMC 0,6 °C -40 °C to 200 °C CMC 0,3 °C 200 °C to 400 °C CMC 0,6 °C 400 °C to 660 °C CMC 0,9 °C KL-PM-0002","search_zh":"热电温度传感器（不带/带变送器）、直读式温度计和带热电偶的测量链 校准 – 温度 在液体槽、干井炉中与 Pt100 标准比较 -196 °C 至 -40 °C CMC 0,6 °C -40 °C 至 200 °C CMC 0,3 °C 200 °C 至 400 °C CMC 0,6 °C 400 °C 至 660 °C CMC 0,9 °C KL-PM-0002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cddcd63d85c45887fd452dcc","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z termoparami","test_object_en":"Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples","test_object_zh":"热电温度传感器（不带/带变送器）、直读式温度计和带热电偶的测量链","test_object_cs":"Termoelektrické snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s termoelektrickými články","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 400 °C do 900 °C","cmc":"0,9 °C"},{"name":"","range":"od 900 °C do 1100 °C","cmc":"1,0 °C"},{"name":"","range":"od 1100 °C do 1200 °C","cmc":"1,5 °C"},{"name":"","range":"od 1200 °C do 1400 °C","cmc":"2,0 °C"},{"name":"","range":"od 1400 °C do 1553 °C","cmc":"2,8 °C"}],"parameters_en":[{"name":"","range":"400 °C to 900 °C","cmc":"0,9 °C"},{"name":"","range":"900 °C to 1100 °C","cmc":"1,0 °C"},{"name":"","range":"1100 °C to 1200 °C","cmc":"1,5 °C"},{"name":"","range":"1200 °C to 1400 °C","cmc":"2,0 °C"},{"name":"","range":"1400 °C to 1553 °C","cmc":"2,8 °C"}],"parameters_zh":[{"name":"","range":"400 °C 至 900 °C","cmc":"0,9 °C"},{"name":"","range":"900 °C 至 1100 °C","cmc":"1,0 °C"},{"name":"","range":"1100 °C 至 1200 °C","cmc":"1,5 °C"},{"name":"","range":"1200 °C 至 1400 °C","cmc":"2,0 °C"},{"name":"","range":"1400 °C 至 1553 °C","cmc":"2,8 °C"}],"parameters_cs":[{"name":"","range":"400 °C až 900 °C","cmc":"0,9 °C"},{"name":"","range":"900 °C až 1100 °C","cmc":"1,0 °C"},{"name":"","range":"1100 °C až 1200 °C","cmc":"1,5 °C"},{"name":"","range":"1200 °C až 1400 °C","cmc":"2,0 °C"},{"name":"","range":"1400 °C až 1553 °C","cmc":"2,8 °C"}],"technique":"Porównanie z termoparami wzorcowymi w piecach poziomych","technique_en":"Comparison with standard thermocouples in horizontal ovens","technique_zh":"在卧式炉中与标准热电偶比较","technique_cs":"Porovnání s etalonovými termoelektrickými články v horizontálních pecích","techniques":["Porównanie z termoparami wzorcowymi w piecach poziomych"],"techniques_en":["Comparison with standard thermocouples in horizontal ovens"],"techniques_zh":["在卧式炉中与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovými termoelektrickými články v horizontálních pecích"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 400 °C do 900 °C CMC 0,9 °C\nod 900 °C do 1100 °C CMC 1,0 °C\nod 1100 °C do 1200 °C CMC 1,5 °C\nod 1200 °C do 1400 °C CMC 2,0 °C\nod 1400 °C do 1553 °C CMC 2,8 °C\nPorównanie z termoparami wzorcowymi w piecach poziomych","reference":"KL-PM-0002","norm_bases":["KL-PM-0002"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z termoparami Wzorcowanie – temperatura Porównanie z termoparami wzorcowymi w piecach poziomych od 400 °C do 900 °C CMC 0,9 °C od 900 °C do 1100 °C CMC 1,0 °C od 1100 °C do 1200 °C CMC 1,5 °C od 1200 °C do 1400 °C CMC 2,0 °C od 1400 °C do 1553 °C CMC 2,8 °C Termoelektrické snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s termoelektrickými články Kalibrace – teplota Porovnání s etalonovými termoelektrickými články v horizontálních pecích 400 °C až 900 °C CMC 0,9 °C 900 °C až 1100 °C CMC 1,0 °C 1100 °C až 1200 °C CMC 1,5 °C 1200 °C až 1400 °C CMC 2,0 °C 1400 °C až 1553 °C CMC 2,8 °C KL-PM-0002 Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezposrednio wskazujace i tory pomiarowe z termoparami Wzorcowanie – temperatura Porownanie z termoparami wzorcowymi w piecach poziomych od 400 °C do 900 °C CMC 0,9 °C od 900 °C do 1100 °C CMC 1,0 °C od 1100 °C do 1200 °C CMC 1,5 °C od 1200 °C do 1400 °C CMC 2,0 °C od 1400 °C do 1553 °C CMC 2,8 °C Termoelektricke snimace teploty (bez prevodniku/s prevodnikem), primoukazujici teplomery a merici retezce s termoelektrickymi clanky Kalibrace – teplota Porovnani s etalonovymi termoelektrickymi clanky v horizontalnich pecich 400 °C az 900 °C CMC 0,9 °C 900 °C az 1100 °C CMC 1,0 °C 1100 °C az 1200 °C CMC 1,5 °C 1200 °C az 1400 °C CMC 2,0 °C 1400 °C az 1553 °C CMC 2,8 °C KL-PM-0002","search_en":"Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples Calibration – temperature Comparison with standard thermocouples in horizontal ovens 400 °C to 900 °C CMC 0,9 °C 900 °C to 1100 °C CMC 1,0 °C 1100 °C to 1200 °C CMC 1,5 °C 1200 °C to 1400 °C CMC 2,0 °C 1400 °C to 1553 °C CMC 2,8 °C KL-PM-0002","search_zh":"热电温度传感器（不带/带变送器）、直读式温度计和带热电偶的测量链 校准 – 温度 在卧式炉中与标准热电偶比较 400 °C 至 900 °C CMC 0,9 °C 900 °C 至 1100 °C CMC 1,0 °C 1100 °C 至 1200 °C CMC 1,5 °C 1200 °C 至 1400 °C CMC 2,0 °C 1400 °C 至 1553 °C CMC 2,8 °C KL-PM-0002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"acd72c52ccc08cd7f6603ffc","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z termoparami","test_object_en":"Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples","test_object_zh":"热电温度传感器（不带/带变送器）、直读式温度计和带热电偶的测量链","test_object_cs":"Termoelektrické snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s termoelektrickými články","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 400 °C do 900 °C","cmc":"0,9 °C"},{"name":"","range":"od 900 °C do 1100 °C","cmc":"1,0 °C"},{"name":"","range":"od 1100 °C do 1200 °C","cmc":"1,5 °C"},{"name":"","range":"od 1200 °C do 1400 °C","cmc":"2,0 °C"},{"name":"","range":"od 1400 °C do 1553 °C","cmc":"2,8 °C"}],"parameters_en":[{"name":"","range":"400 °C to 900 °C","cmc":"0,9 °C"},{"name":"","range":"900 °C to 1100 °C","cmc":"1,0 °C"},{"name":"","range":"1100 °C to 1200 °C","cmc":"1,5 °C"},{"name":"","range":"1200 °C to 1400 °C","cmc":"2,0 °C"},{"name":"","range":"1400 °C to 1553 °C","cmc":"2,8 °C"}],"parameters_zh":[{"name":"","range":"400 °C 至 900 °C","cmc":"0,9 °C"},{"name":"","range":"900 °C 至 1100 °C","cmc":"1,0 °C"},{"name":"","range":"1100 °C 至 1200 °C","cmc":"1,5 °C"},{"name":"","range":"1200 °C 至 1400 °C","cmc":"2,0 °C"},{"name":"","range":"1400 °C 至 1553 °C","cmc":"2,8 °C"}],"parameters_cs":[{"name":"","range":"400 °C až 900 °C","cmc":"0,9 °C"},{"name":"","range":"900 °C až 1100 °C","cmc":"1,0 °C"},{"name":"","range":"1100 °C až 1200 °C","cmc":"1,5 °C"},{"name":"","range":"1200 °C až 1400 °C","cmc":"2,0 °C"},{"name":"","range":"1400 °C až 1553 °C","cmc":"2,8 °C"}],"technique":"Porównanie z termoparami wzorcowymi w piecach poziomych","technique_en":"Comparison with standard thermocouples in horizontal ovens","technique_zh":"在卧式炉中与标准热电偶比较","technique_cs":"Porovnání s etalonovými termoelektrickými články v horizontálních pecích","techniques":["Porównanie z termoparami wzorcowymi w piecach poziomych"],"techniques_en":["Comparison with standard thermocouples in horizontal ovens"],"techniques_zh":["在卧式炉中与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovými termoelektrickými články v horizontálních pecích"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 400 °C do 900 °C CMC 0,9 °C\nod 900 °C do 1100 °C CMC 1,0 °C\nod 1100 °C do 1200 °C CMC 1,5 °C\nod 1200 °C do 1400 °C CMC 2,0 °C\nod 1400 °C do 1553 °C CMC 2,8 °C\nPorównanie z termoparami wzorcowymi w piecach poziomych","reference":"KL-PM-0002","norm_bases":["KL-PM-0002"],"lab_section":"Pracownia Pardubice","lab_section_en":"Workplace Pardubice","lab_section_zh":"Pardubice 工作场所","lab_section_cs":"Pracoviště Pardubice","lab_address":"budova M 84, Semtín 103, 530 02 Pardubice","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezpośrednio wskazujące i tory pomiarowe z termoparami Wzorcowanie – temperatura Porównanie z termoparami wzorcowymi w piecach poziomych od 400 °C do 900 °C CMC 0,9 °C od 900 °C do 1100 °C CMC 1,0 °C od 1100 °C do 1200 °C CMC 1,5 °C od 1200 °C do 1400 °C CMC 2,0 °C od 1400 °C do 1553 °C CMC 2,8 °C Termoelektrické snímače teploty (bez převodníku/s převodníkem), přímoukazující teploměry a měřicí řetězce s termoelektrickými články Kalibrace – teplota Porovnání s etalonovými termoelektrickými články v horizontálních pecích 400 °C až 900 °C CMC 0,9 °C 900 °C až 1100 °C CMC 1,0 °C 1100 °C až 1200 °C CMC 1,5 °C 1200 °C až 1400 °C CMC 2,0 °C 1400 °C až 1553 °C CMC 2,8 °C KL-PM-0002 Termoelektryczne czujniki temperatury (bez przetwornika/z przetwornikiem), termometry bezposrednio wskazujace i tory pomiarowe z termoparami Wzorcowanie – temperatura Porownanie z termoparami wzorcowymi w piecach poziomych od 400 °C do 900 °C CMC 0,9 °C od 900 °C do 1100 °C CMC 1,0 °C od 1100 °C do 1200 °C CMC 1,5 °C od 1200 °C do 1400 °C CMC 2,0 °C od 1400 °C do 1553 °C CMC 2,8 °C Termoelektricke snimace teploty (bez prevodniku/s prevodnikem), primoukazujici teplomery a merici retezce s termoelektrickymi clanky Kalibrace – teplota Porovnani s etalonovymi termoelektrickymi clanky v horizontalnich pecich 400 °C az 900 °C CMC 0,9 °C 900 °C az 1100 °C CMC 1,0 °C 1100 °C az 1200 °C CMC 1,5 °C 1200 °C az 1400 °C CMC 2,0 °C 1400 °C az 1553 °C CMC 2,8 °C KL-PM-0002","search_en":"Thermoelectric temperature sensors (with/without a transducer), direct indicating thermometers and measuring chains with thermocouples Calibration – temperature Comparison with standard thermocouples in horizontal ovens 400 °C to 900 °C CMC 0,9 °C 900 °C to 1100 °C CMC 1,0 °C 1100 °C to 1200 °C CMC 1,5 °C 1200 °C to 1400 °C CMC 2,0 °C 1400 °C to 1553 °C CMC 2,8 °C KL-PM-0002","search_zh":"热电温度传感器（不带/带变送器）、直读式温度计和带热电偶的测量链 校准 – 温度 在卧式炉中与标准热电偶比较 400 °C 至 900 °C CMC 0,9 °C 900 °C 至 1100 °C CMC 1,0 °C 1100 °C 至 1200 °C CMC 1,5 °C 1200 °C 至 1400 °C CMC 2,0 °C 1400 °C 至 1553 °C CMC 2,8 °C KL-PM-0002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b6b71944ccf6de24db830a9","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"3","test_object":"Termometry tarczowe","test_object_en":"Dial thermometers","test_object_zh":"表盘式温度计","test_object_cs":"Číselníkové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 200 °C","cmc":"0,2 °C"},{"name":"","range":"od 200 °C do 500 °C","cmc":"0,7 °C"},{"name":"","range":"od 500 °C do 660 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C to 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C to 660 °C","cmc":"1,2 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C 至 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C 至 660 °C","cmc":"1,2 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C až 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C až 660 °C","cmc":"1,2 °C"}],"technique":"Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych.","technique_en":"Comparison with a Pt100 standard in liquid baths and dry block calibrators","technique_zh":"在液体槽或干井炉中与 Pt100 标准比较","technique_cs":"Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách.","techniques":["Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych."],"techniques_en":["Comparison with a Pt100 standard in liquid baths and dry block calibrators"],"techniques_zh":["在液体槽或干井炉中与 Pt100 标准比较"],"techniques_cs":["Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách."],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do 200 °C CMC 0,2 °C\nod 200 °C do 500 °C CMC 0,7 °C\nod 500 °C do 660 °C CMC 1,2 °C\nPorównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych.","reference":"KL-PM-0005","norm_bases":["KL-PM-0005"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry tarczowe Wzorcowanie – temperatura Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych. od -40 °C do 200 °C CMC 0,2 °C od 200 °C do 500 °C CMC 0,7 °C od 500 °C do 660 °C CMC 1,2 °C Číselníkové teploměry Kalibrace – teplota Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách. -40 °C až 200 °C CMC 0,2 °C 200 °C až 500 °C CMC 0,7 °C 500 °C až 660 °C CMC 1,2 °C KL-PM-0005 Termometry tarczowe Wzorcowanie – temperatura Porownanie z wzorcem Pt100 w lazniach cieczowych lub piecykach blokowych. od -40 °C do 200 °C CMC 0,2 °C od 200 °C do 500 °C CMC 0,7 °C od 500 °C do 660 °C CMC 1,2 °C Ciselnikove teplomery Kalibrace – teplota Porovnani s etalonem Pt100 v kapalinovych laznich nebo blokovych pickach. -40 °C az 200 °C CMC 0,2 °C 200 °C az 500 °C CMC 0,7 °C 500 °C az 660 °C CMC 1,2 °C KL-PM-0005","search_en":"Dial thermometers Calibration – temperature Comparison with a Pt100 standard in liquid baths and dry block calibrators -40 °C to 200 °C CMC 0,2 °C 200 °C to 500 °C CMC 0,7 °C 500 °C to 660 °C CMC 1,2 °C KL-PM-0005","search_zh":"表盘式温度计 校准 – 温度 在液体槽或干井炉中与 Pt100 标准比较 -40 °C 至 200 °C CMC 0,2 °C 200 °C 至 500 °C CMC 0,7 °C 500 °C 至 660 °C CMC 1,2 °C KL-PM-0005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dbe6f103bf676182bb63378a","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"3","test_object":"Termometry tarczowe","test_object_en":"Dial thermometers","test_object_zh":"表盘式温度计","test_object_cs":"Číselníkové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 200 °C","cmc":"0,2 °C"},{"name":"","range":"od 200 °C do 500 °C","cmc":"0,7 °C"},{"name":"","range":"od 500 °C do 660 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C to 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C to 660 °C","cmc":"1,2 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C 至 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C 至 660 °C","cmc":"1,2 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C až 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C až 660 °C","cmc":"1,2 °C"}],"technique":"Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych.","technique_en":"Comparison with a Pt100 standard in liquid baths and dry block calibrators","technique_zh":"在液体槽或干井炉中与 Pt100 标准比较","technique_cs":"Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách.","techniques":["Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych."],"techniques_en":["Comparison with a Pt100 standard in liquid baths and dry block calibrators"],"techniques_zh":["在液体槽或干井炉中与 Pt100 标准比较"],"techniques_cs":["Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách."],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do 200 °C CMC 0,2 °C\nod 200 °C do 500 °C CMC 0,7 °C\nod 500 °C do 660 °C CMC 1,2 °C\nPorównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych.","reference":"KL-PM-0005","norm_bases":["KL-PM-0005"],"lab_section":"Pracownia Pardubice","lab_section_en":"Workplace Pardubice","lab_section_zh":"Pardubice 工作场所","lab_section_cs":"Pracoviště Pardubice","lab_address":"budova M 84, Semtín 103, 530 02 Pardubice","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry tarczowe Wzorcowanie – temperatura Porównanie z wzorcem Pt100 w łaźniach cieczowych lub piecykach blokowych. od -40 °C do 200 °C CMC 0,2 °C od 200 °C do 500 °C CMC 0,7 °C od 500 °C do 660 °C CMC 1,2 °C Číselníkové teploměry Kalibrace – teplota Porovnání s etalonem Pt100 v kapalinových lázních nebo blokových píckách. -40 °C až 200 °C CMC 0,2 °C 200 °C až 500 °C CMC 0,7 °C 500 °C až 660 °C CMC 1,2 °C KL-PM-0005 Termometry tarczowe Wzorcowanie – temperatura Porownanie z wzorcem Pt100 w lazniach cieczowych lub piecykach blokowych. od -40 °C do 200 °C CMC 0,2 °C od 200 °C do 500 °C CMC 0,7 °C od 500 °C do 660 °C CMC 1,2 °C Ciselnikove teplomery Kalibrace – teplota Porovnani s etalonem Pt100 v kapalinovych laznich nebo blokovych pickach. -40 °C az 200 °C CMC 0,2 °C 200 °C az 500 °C CMC 0,7 °C 500 °C az 660 °C CMC 1,2 °C KL-PM-0005","search_en":"Dial thermometers Calibration – temperature Comparison with a Pt100 standard in liquid baths and dry block calibrators -40 °C to 200 °C CMC 0,2 °C 200 °C to 500 °C CMC 0,7 °C 500 °C to 660 °C CMC 1,2 °C KL-PM-0005","search_zh":"表盘式温度计 校准 – 温度 在液体槽或干井炉中与 Pt100 标准比较 -40 °C 至 200 °C CMC 0,2 °C 200 °C 至 500 °C CMC 0,7 °C 500 °C 至 660 °C CMC 1,2 °C KL-PM-0005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"81de64070a0c63576c1ccb1a","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"4","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"od 0 °C do 100 °C","cmc":"0,06 °C"},{"name":"","range":"od 100 °C do 230 °C","cmc":"0,07 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C to 100 °C","cmc":"0,06 °C"},{"name":"","range":"100 °C to 230 °C","cmc":"0,07 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C 至 100 °C","cmc":"0,06 °C"},{"name":"","range":"100 °C 至 230 °C","cmc":"0,07 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C až 100 °C","cmc":"0,06 °C"},{"name":"","range":"100 °C až 230 °C","cmc":"0,07 °C"}],"technique":"Porównanie z wzorcem Pt100 w łaźniach cieczowych.","technique_en":"Comparison with a Pt100 standard in liquid baths.","technique_zh":"在液体槽中与 Pt100 标准比较。","technique_cs":"Porovnání s etalonem Pt100 v kapalinových lázních.","techniques":["Porównanie z wzorcem Pt100 w łaźniach cieczowych."],"techniques_en":["Comparison with a Pt100 standard in liquid baths."],"techniques_zh":["在液体槽中与 Pt100 标准比较。"],"techniques_cs":["Porovnání s etalonem Pt100 v kapalinových lázních."],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do 0 °C CMC 0,06 °C\n0 °C CMC 0,05 °C\nod 0 °C do 100 °C CMC 0,06 °C\nod 100 °C do 230 °C CMC 0,07 °C\nPorównanie z wzorcem Pt100 w łaźniach cieczowych.","reference":"KL-PM-0005","norm_bases":["KL-PM-0005"],"lab_section":"Pracownia Pardubice","lab_section_en":"Workplace Pardubice","lab_section_zh":"Pardubice 工作场所","lab_section_cs":"Pracoviště Pardubice","lab_address":"budova M 84, Semtín 103, 530 02 Pardubice","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z wzorcem Pt100 w łaźniach cieczowych. od -40 °C do 0 °C CMC 0,06 °C 0 °C CMC 0,05 °C od 0 °C do 100 °C CMC 0,06 °C od 100 °C do 230 °C CMC 0,07 °C Skleněné teploměry Kalibrace – teplota Porovnání s etalonem Pt100 v kapalinových lázních. -40 °C až 0 °C CMC 0,06 °C 0 °C CMC 0,05 °C 0 °C až 100 °C CMC 0,06 °C 100 °C až 230 °C CMC 0,07 °C KL-PM-0005 Termometry szklane Wzorcowanie – temperatura Porownanie z wzorcem Pt100 w lazniach cieczowych. od -40 °C do 0 °C CMC 0,06 °C 0 °C CMC 0,05 °C od 0 °C do 100 °C CMC 0,06 °C od 100 °C do 230 °C CMC 0,07 °C Sklenene teplomery Kalibrace – teplota Porovnani s etalonem Pt100 v kapalinovych laznich. -40 °C az 0 °C CMC 0,06 °C 0 °C CMC 0,05 °C 0 °C az 100 °C CMC 0,06 °C 100 °C az 230 °C CMC 0,07 °C KL-PM-0005","search_en":"Glass thermometers Calibration – temperature Comparison with a Pt100 standard in liquid baths. -40 °C to 0 °C CMC 0,06 °C 0 °C CMC 0,05 °C 0 °C to 100 °C CMC 0,06 °C 100 °C to 230 °C CMC 0,07 °C KL-PM-0005","search_zh":"玻璃温度计 校准 – 温度 在液体槽中与 Pt100 标准比较。 -40 °C 至 0 °C CMC 0,06 °C 0 °C CMC 0,05 °C 0 °C 至 100 °C CMC 0,06 °C 100 °C 至 230 °C CMC 0,07 °C KL-PM-0005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"736eb0a068629792126d5107","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność względna / higrometry i tory pomiarowe wilgotności wraz z sondami wilgotności","test_object_en":"Relative humidity / hygrometers and measuring chains incl. humidity probes","test_object_zh":"相对湿度 / 湿度计和湿度测量链（含湿度探头）","test_object_cs":"Relativní vlhkost / vlhkoměry a měřicí řetězce vlhkosti včetně vlhkostních sond","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"temperatura powietrza (7 do 90) °C","range":"od 5 % RH do 30 % RH","cmc":"1,2 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 30 % RH do 50 % RH","cmc":"1,3 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 50 % RH do 70 % RH","cmc":"1,4 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 70 % RH do 80 % RH","cmc":"1,5 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 80 % RH do 90 % RH","cmc":"1,6 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 90 % RH do 95 % RH","cmc":"1,8 % RH"}],"parameters_en":[{"name":"Air Temperature (7 to 90) °C","range":"5 % RH to 30 % RH","cmc":"1,2 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"30 % RH to 50 % RH","cmc":"1,3 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"50 % RH to 70 % RH","cmc":"1,4 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"70 % RH to 80 % RH","cmc":"1,5 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"80 % RH to 90 % RH","cmc":"1,6 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"90 % RH to 95 % RH","cmc":"1,8 % RH"}],"parameters_zh":[{"name":"空气温度 (7 至 90) °C","range":"5 % RH 至 30 % RH","cmc":"1,2 % RH"},{"name":"空气温度 (7 至 90) °C","range":"30 % RH 至 50 % RH","cmc":"1,3 % RH"},{"name":"空气温度 (7 至 90) °C","range":"50 % RH 至 70 % RH","cmc":"1,4 % RH"},{"name":"空气温度 (7 至 90) °C","range":"70 % RH 至 80 % RH","cmc":"1,5 % RH"},{"name":"空气温度 (7 至 90) °C","range":"80 % RH 至 90 % RH","cmc":"1,6 % RH"},{"name":"空气温度 (7 至 90) °C","range":"90 % RH 至 95 % RH","cmc":"1,8 % RH"}],"parameters_cs":[{"name":"teplota vzduchu (7 až 90) °C","range":"5 % RH až 30 % RH","cmc":"1,2 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"30 % RH až 50 % RH","cmc":"1,3 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"50 % RH až 70 % RH","cmc":"1,4 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"70 % RH až 80 % RH","cmc":"1,5 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"80 % RH až 90 % RH","cmc":"1,6 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"90 % RH až 95 % RH","cmc":"1,8 % RH"}],"technique":"Porównanie z higrometrem wzorcowym","technique_en":"Comparison with a reference hygrometer","technique_zh":"与标准湿度计比较","technique_cs":"Porovnání s etalonovým vlhkoměrem","techniques":["Porównanie z higrometrem wzorcowym"],"techniques_en":["Comparison with a reference hygrometer"],"techniques_zh":["与标准湿度计比较"],"techniques_cs":["Porovnání s etalonovým vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\ntemperatura powietrza (7 do 90) °C od 5 % RH do 30 % RH CMC 1,2 % RH\ntemperatura powietrza (7 do 90) °C od 30 % RH do 50 % RH CMC 1,3 % RH\ntemperatura powietrza (7 do 90) °C od 50 % RH do 70 % RH CMC 1,4 % RH\ntemperatura powietrza (7 do 90) °C od 70 % RH do 80 % RH CMC 1,5 % RH\ntemperatura powietrza (7 do 90) °C od 80 % RH do 90 % RH CMC 1,6 % RH\ntemperatura powietrza (7 do 90) °C od 90 % RH do 95 % RH CMC 1,8 % RH\nPorównanie z higrometrem wzorcowym","reference":"KL-PM-0201","norm_bases":["KL-PM-0201"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność względna / higrometry i tory pomiarowe wilgotności wraz z sondami wilgotności Wzorcowanie – wilgotność powietrza Porównanie z higrometrem wzorcowym temperatura powietrza (7 do 90) °C od 5 % RH do 30 % RH CMC 1,2 % RH temperatura powietrza (7 do 90) °C od 30 % RH do 50 % RH CMC 1,3 % RH temperatura powietrza (7 do 90) °C od 50 % RH do 70 % RH CMC 1,4 % RH temperatura powietrza (7 do 90) °C od 70 % RH do 80 % RH CMC 1,5 % RH temperatura powietrza (7 do 90) °C od 80 % RH do 90 % RH CMC 1,6 % RH temperatura powietrza (7 do 90) °C od 90 % RH do 95 % RH CMC 1,8 % RH Relativní vlhkost / vlhkoměry a měřicí řetězce vlhkosti včetně vlhkostních sond Kalibrace – vlhkost vzduchu Porovnání s etalonovým vlhkoměrem teplota vzduchu (7 až 90) °C 5 % RH až 30 % RH CMC 1,2 % RH teplota vzduchu (7 až 90) °C 30 % RH až 50 % RH CMC 1,3 % RH teplota vzduchu (7 až 90) °C 50 % RH až 70 % RH CMC 1,4 % RH teplota vzduchu (7 až 90) °C 70 % RH až 80 % RH CMC 1,5 % RH teplota vzduchu (7 až 90) °C 80 % RH až 90 % RH CMC 1,6 % RH teplota vzduchu (7 až 90) °C 90 % RH až 95 % RH CMC 1,8 % RH KL-PM-0201 Wilgotnosc wzgledna / higrometry i tory pomiarowe wilgotnosci wraz z sondami wilgotnosci Wzorcowanie – wilgotnosc powietrza Porownanie z higrometrem wzorcowym temperatura powietrza (7 do 90) °C od 5 % RH do 30 % RH CMC 1,2 % RH temperatura powietrza (7 do 90) °C od 30 % RH do 50 % RH CMC 1,3 % RH temperatura powietrza (7 do 90) °C od 50 % RH do 70 % RH CMC 1,4 % RH temperatura powietrza (7 do 90) °C od 70 % RH do 80 % RH CMC 1,5 % RH temperatura powietrza (7 do 90) °C od 80 % RH do 90 % RH CMC 1,6 % RH temperatura powietrza (7 do 90) °C od 90 % RH do 95 % RH CMC 1,8 % RH Relativni vlhkost / vlhkomery a merici retezce vlhkosti vcetne vlhkostnich sond Kalibrace – vlhkost vzduchu Porovnani s etalonovym vlhkomerem teplota vzduchu (7 az 90) °C 5 % RH az 30 % RH CMC 1,2 % RH teplota vzduchu (7 az 90) °C 30 % RH az 50 % RH CMC 1,3 % RH teplota vzduchu (7 az 90) °C 50 % RH az 70 % RH CMC 1,4 % RH teplota vzduchu (7 az 90) °C 70 % RH az 80 % RH CMC 1,5 % RH teplota vzduchu (7 az 90) °C 80 % RH az 90 % RH CMC 1,6 % RH teplota vzduchu (7 az 90) °C 90 % RH az 95 % RH CMC 1,8 % RH KL-PM-0201","search_en":"Relative humidity / hygrometers and measuring chains incl. humidity probes Calibration – air humidity Comparison with a reference hygrometer Air Temperature (7 to 90) °C 5 % RH to 30 % RH CMC 1,2 % RH Air Temperature (7 to 90) °C 30 % RH to 50 % RH CMC 1,3 % RH Air Temperature (7 to 90) °C 50 % RH to 70 % RH CMC 1,4 % RH Air Temperature (7 to 90) °C 70 % RH to 80 % RH CMC 1,5 % RH Air Temperature (7 to 90) °C 80 % RH to 90 % RH CMC 1,6 % RH Air Temperature (7 to 90) °C 90 % RH to 95 % RH CMC 1,8 % RH KL-PM-0201","search_zh":"相对湿度 / 湿度计和湿度测量链（含湿度探头） 校准 – 空气湿度 与标准湿度计比较 空气温度 (7 至 90) °C 5 % RH 至 30 % RH CMC 1,2 % RH 空气温度 (7 至 90) °C 30 % RH 至 50 % RH CMC 1,3 % RH 空气温度 (7 至 90) °C 50 % RH 至 70 % RH CMC 1,4 % RH 空气温度 (7 至 90) °C 70 % RH 至 80 % RH CMC 1,5 % RH 空气温度 (7 至 90) °C 80 % RH 至 90 % RH CMC 1,6 % RH 空气温度 (7 至 90) °C 90 % RH 至 95 % RH CMC 1,8 % RH KL-PM-0201","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"98c04d9f14372f705c9a9a2a","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność względna / higrometry i tory pomiarowe wilgotności wraz z sondami wilgotności","test_object_en":"Relative humidity / hygrometers and measuring chains incl. humidity probes","test_object_zh":"相对湿度 / 湿度计和湿度测量链（含湿度探头）","test_object_cs":"Relativní vlhkost / vlhkoměry a měřicí řetězce vlhkosti včetně vlhkostních sond","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"temperatura powietrza (7 do 90) °C","range":"od 5 % RH do 30 % RH","cmc":"1,2 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 30 % RH do 50 % RH","cmc":"1,3 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 50 % RH do 70 % RH","cmc":"1,4 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 70 % RH do 80 % RH","cmc":"1,5 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 80 % RH do 90 % RH","cmc":"1,6 % RH"},{"name":"temperatura powietrza (7 do 90) °C","range":"od 90 % RH do 95 % RH","cmc":"1,8 % RH"}],"parameters_en":[{"name":"Air Temperature (7 to 90) °C","range":"5 % RH to 30 % RH","cmc":"1,2 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"30 % RH to 50 % RH","cmc":"1,3 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"50 % RH to 70 % RH","cmc":"1,4 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"70 % RH to 80 % RH","cmc":"1,5 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"80 % RH to 90 % RH","cmc":"1,6 % RH"},{"name":"Air Temperature (7 to 90) °C","range":"90 % RH to 95 % RH","cmc":"1,8 % RH"}],"parameters_zh":[{"name":"空气温度 (7 至 90) °C","range":"5 % RH 至 30 % RH","cmc":"1,2 % RH"},{"name":"空气温度 (7 至 90) °C","range":"30 % RH 至 50 % RH","cmc":"1,3 % RH"},{"name":"空气温度 (7 至 90) °C","range":"50 % RH 至 70 % RH","cmc":"1,4 % RH"},{"name":"空气温度 (7 至 90) °C","range":"70 % RH 至 80 % RH","cmc":"1,5 % RH"},{"name":"空气温度 (7 至 90) °C","range":"80 % RH 至 90 % RH","cmc":"1,6 % RH"},{"name":"空气温度 (7 至 90) °C","range":"90 % RH 至 95 % RH","cmc":"1,8 % RH"}],"parameters_cs":[{"name":"teplota vzduchu (7 až 90) °C","range":"5 % RH až 30 % RH","cmc":"1,2 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"30 % RH až 50 % RH","cmc":"1,3 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"50 % RH až 70 % RH","cmc":"1,4 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"70 % RH až 80 % RH","cmc":"1,5 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"80 % RH až 90 % RH","cmc":"1,6 % RH"},{"name":"teplota vzduchu (7 až 90) °C","range":"90 % RH až 95 % RH","cmc":"1,8 % RH"}],"technique":"Porównanie z higrometrem wzorcowym","technique_en":"Comparison with a reference hygrometer","technique_zh":"与标准湿度计比较","technique_cs":"Porovnání s etalonovým vlhkoměrem","techniques":["Porównanie z higrometrem wzorcowym"],"techniques_en":["Comparison with a reference hygrometer"],"techniques_zh":["与标准湿度计比较"],"techniques_cs":["Porovnání s etalonovým vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\ntemperatura powietrza (7 do 90) °C od 5 % RH do 30 % RH CMC 1,2 % RH\ntemperatura powietrza (7 do 90) °C od 30 % RH do 50 % RH CMC 1,3 % RH\ntemperatura powietrza (7 do 90) °C od 50 % RH do 70 % RH CMC 1,4 % RH\ntemperatura powietrza (7 do 90) °C od 70 % RH do 80 % RH CMC 1,5 % RH\ntemperatura powietrza (7 do 90) °C od 80 % RH do 90 % RH CMC 1,6 % RH\ntemperatura powietrza (7 do 90) °C od 90 % RH do 95 % RH CMC 1,8 % RH\nPorównanie z higrometrem wzorcowym","reference":"KL-PM-0201","norm_bases":["KL-PM-0201"],"lab_section":"Pracownia Pardubice","lab_section_en":"Workplace Pardubice","lab_section_zh":"Pardubice 工作场所","lab_section_cs":"Pracoviště Pardubice","lab_address":"budova M 84, Semtín 103, 530 02 Pardubice","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność względna / higrometry i tory pomiarowe wilgotności wraz z sondami wilgotności Wzorcowanie – wilgotność powietrza Porównanie z higrometrem wzorcowym temperatura powietrza (7 do 90) °C od 5 % RH do 30 % RH CMC 1,2 % RH temperatura powietrza (7 do 90) °C od 30 % RH do 50 % RH CMC 1,3 % RH temperatura powietrza (7 do 90) °C od 50 % RH do 70 % RH CMC 1,4 % RH temperatura powietrza (7 do 90) °C od 70 % RH do 80 % RH CMC 1,5 % RH temperatura powietrza (7 do 90) °C od 80 % RH do 90 % RH CMC 1,6 % RH temperatura powietrza (7 do 90) °C od 90 % RH do 95 % RH CMC 1,8 % RH Relativní vlhkost / vlhkoměry a měřicí řetězce vlhkosti včetně vlhkostních sond Kalibrace – vlhkost vzduchu Porovnání s etalonovým vlhkoměrem teplota vzduchu (7 až 90) °C 5 % RH až 30 % RH CMC 1,2 % RH teplota vzduchu (7 až 90) °C 30 % RH až 50 % RH CMC 1,3 % RH teplota vzduchu (7 až 90) °C 50 % RH až 70 % RH CMC 1,4 % RH teplota vzduchu (7 až 90) °C 70 % RH až 80 % RH CMC 1,5 % RH teplota vzduchu (7 až 90) °C 80 % RH až 90 % RH CMC 1,6 % RH teplota vzduchu (7 až 90) °C 90 % RH až 95 % RH CMC 1,8 % RH KL-PM-0201 Wilgotnosc wzgledna / higrometry i tory pomiarowe wilgotnosci wraz z sondami wilgotnosci Wzorcowanie – wilgotnosc powietrza Porownanie z higrometrem wzorcowym temperatura powietrza (7 do 90) °C od 5 % RH do 30 % RH CMC 1,2 % RH temperatura powietrza (7 do 90) °C od 30 % RH do 50 % RH CMC 1,3 % RH temperatura powietrza (7 do 90) °C od 50 % RH do 70 % RH CMC 1,4 % RH temperatura powietrza (7 do 90) °C od 70 % RH do 80 % RH CMC 1,5 % RH temperatura powietrza (7 do 90) °C od 80 % RH do 90 % RH CMC 1,6 % RH temperatura powietrza (7 do 90) °C od 90 % RH do 95 % RH CMC 1,8 % RH Relativni vlhkost / vlhkomery a merici retezce vlhkosti vcetne vlhkostnich sond Kalibrace – vlhkost vzduchu Porovnani s etalonovym vlhkomerem teplota vzduchu (7 az 90) °C 5 % RH az 30 % RH CMC 1,2 % RH teplota vzduchu (7 az 90) °C 30 % RH az 50 % RH CMC 1,3 % RH teplota vzduchu (7 az 90) °C 50 % RH az 70 % RH CMC 1,4 % RH teplota vzduchu (7 az 90) °C 70 % RH az 80 % RH CMC 1,5 % RH teplota vzduchu (7 az 90) °C 80 % RH az 90 % RH CMC 1,6 % RH teplota vzduchu (7 az 90) °C 90 % RH az 95 % RH CMC 1,8 % RH KL-PM-0201","search_en":"Relative humidity / hygrometers and measuring chains incl. humidity probes Calibration – air humidity Comparison with a reference hygrometer Air Temperature (7 to 90) °C 5 % RH to 30 % RH CMC 1,2 % RH Air Temperature (7 to 90) °C 30 % RH to 50 % RH CMC 1,3 % RH Air Temperature (7 to 90) °C 50 % RH to 70 % RH CMC 1,4 % RH Air Temperature (7 to 90) °C 70 % RH to 80 % RH CMC 1,5 % RH Air Temperature (7 to 90) °C 80 % RH to 90 % RH CMC 1,6 % RH Air Temperature (7 to 90) °C 90 % RH to 95 % RH CMC 1,8 % RH KL-PM-0201","search_zh":"相对湿度 / 湿度计和湿度测量链（含湿度探头） 校准 – 空气湿度 与标准湿度计比较 空气温度 (7 至 90) °C 5 % RH 至 30 % RH CMC 1,2 % RH 空气温度 (7 至 90) °C 30 % RH 至 50 % RH CMC 1,3 % RH 空气温度 (7 至 90) °C 50 % RH 至 70 % RH CMC 1,4 % RH 空气温度 (7 至 90) °C 70 % RH 至 80 % RH CMC 1,5 % RH 空气温度 (7 至 90) °C 80 % RH 至 90 % RH CMC 1,6 % RH 空气温度 (7 至 90) °C 90 % RH 至 95 % RH CMC 1,8 % RH KL-PM-0201","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"474444cd76709d7b8bbc2e03","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"1","test_object":"Pomiar i symulacja sygnałów czujników temperatury (rezystancyjne czujniki temperatury, termopary)","test_object_en":"Measurement and simulation of temperature sensor signals (resistance temperature sensors, thermocouples)","test_object_zh":"温度传感器信号的测量和模拟（电阻温度传感器、热电偶）","test_object_cs":"Měření a simulace signálů snímačů teploty (odporové snímače teploty, termoelektrické články)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 Ω do 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"od 0,1 kΩ do 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"od -10 mV do 100 mV","cmc":"0,00081 % + 0,54 µV"}],"parameters_en":[{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"-10 mV to 100 mV","cmc":"0,00081 % + 0,54 µV"}],"parameters_zh":[{"name":"","range":"10 Ω 至 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"0,1 kΩ 至 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"-10 mV 至 100 mV","cmc":"0,00081 % + 0,54 µV"}],"parameters_cs":[{"name":"","range":"10 Ω až 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"0,1 kΩ až 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"-10 mV až 100 mV","cmc":"0,00081 % + 0,54 µV"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 10 Ω do 100 Ω CMC 0,0015 % + 0,23 mΩ\nod 0,1 kΩ do 1 kΩ CMC 0,0013 % + 1,8 mΩ\nod 1 kΩ do 10 kΩ CMC 0,0015 % + 18 mΩ\nod -10 mV do 100 mV CMC 0,00081 % + 0,54 µV\nPorównanie z multimetrem wzorcowym","reference":"KL-PM-0006","norm_bases":["KL-PM-0006"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomiar i symulacja sygnałów czujników temperatury (rezystancyjne czujniki temperatury, termopary) Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym od 10 Ω do 100 Ω CMC 0,0015 % + 0,23 mΩ od 0,1 kΩ do 1 kΩ CMC 0,0013 % + 1,8 mΩ od 1 kΩ do 10 kΩ CMC 0,0015 % + 18 mΩ od -10 mV do 100 mV CMC 0,00081 % + 0,54 µV Měření a simulace signálů snímačů teploty (odporové snímače teploty, termoelektrické články) Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 10 Ω až 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ až 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ až 10 kΩ CMC 0,0015 % + 18 mΩ -10 mV až 100 mV CMC 0,00081 % + 0,54 µV KL-PM-0006 Pomiar i symulacja sygnalow czujnikow temperatury (rezystancyjne czujniki temperatury, termopary) Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym od 10 Ω do 100 Ω CMC 0,0015 % + 0,23 mΩ od 0,1 kΩ do 1 kΩ CMC 0,0013 % + 1,8 mΩ od 1 kΩ do 10 kΩ CMC 0,0015 % + 18 mΩ od -10 mV do 100 mV CMC 0,00081 % + 0,54 µV Mereni a simulace signalu snimacu teploty (odporove snimace teploty, termoelektricke clanky) Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 10 Ω az 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ az 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ az 10 kΩ CMC 0,0015 % + 18 mΩ -10 mV az 100 mV CMC 0,00081 % + 0,54 µV KL-PM-0006","search_en":"Measurement and simulation of temperature sensor signals (resistance temperature sensors, thermocouples) Calibration – electrical quantities Comparison with a reference multimeter 10 Ω to 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ to 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ to 10 kΩ CMC 0,0015 % + 18 mΩ -10 mV to 100 mV CMC 0,00081 % + 0,54 µV KL-PM-0006","search_zh":"温度传感器信号的测量和模拟（电阻温度传感器、热电偶） 校准 – 电学量 与标准万用表比较 10 Ω 至 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ 至 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ 至 10 kΩ CMC 0,0015 % + 18 mΩ -10 mV 至 100 mV CMC 0,00081 % + 0,54 µV KL-PM-0006","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d63d6cace0128c1cf619c09f","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"2","test_object":"Napięcie stałe / mierniki napięcia stałego","test_object_en":"DC voltage / DC voltage meters","test_object_zh":"直流电压 / 直流电压表","test_object_cs":"Stejnosměrné napětí / měřidla stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,00081 % + 0,54 µV"},{"name":"","range":"od 0,1 V do 1 V","cmc":"0,00064 % + 2,6 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,00064 % + 7,6 µV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,00092 % + 97 µV"},{"name":"","range":"od 100 V do 1000 V","cmc":"0,00092 % + 1,4 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,00081 % + 0,54 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"0,00064 % + 2,6 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,00064 % + 7,6 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,00092 % + 97 µV"},{"name":"","range":"100 V to 1000 V","cmc":"0,00092 % + 1,4 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,00081 % + 0,54 µV"},{"name":"","range":"0,1 V 至 1 V","cmc":"0,00064 % + 2,6 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,00064 % + 7,6 µV"},{"name":"","range":"10 V 至 100 V","cmc":"0,00092 % + 97 µV"},{"name":"","range":"100 V 至 1000 V","cmc":"0,00092 % + 1,4 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,00081 % + 0,54 µV"},{"name":"","range":"0,1 V až 1 V","cmc":"0,00064 % + 2,6 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,00064 % + 7,6 µV"},{"name":"","range":"10 V až 100 V","cmc":"0,00092 % + 97 µV"},{"name":"","range":"100 V až 1000 V","cmc":"0,00092 % + 1,4 mV"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,00081 % + 0,54 µV\nod 0,1 V do 1 V CMC 0,00064 % + 2,6 µV\nod 1 V do 10 V CMC 0,00064 % + 7,6 µV\nod 10 V do 100 V CMC 0,00092 % + 97 µV\nod 100 V do 1000 V CMC 0,00092 % + 1,4 mV\nPorównanie z multimetrem wzorcowym","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / mierniki napięcia stałego Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,00081 % + 0,54 µV od 0,1 V do 1 V CMC 0,00064 % + 2,6 µV od 1 V do 10 V CMC 0,00064 % + 7,6 µV od 10 V do 100 V CMC 0,00092 % + 97 µV od 100 V do 1000 V CMC 0,00092 % + 1,4 mV Stejnosměrné napětí / měřidla stejnosměrného napětí Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 0 mV až 100 mV CMC 0,00081 % + 0,54 µV 0,1 V až 1 V CMC 0,00064 % + 2,6 µV 1 V až 10 V CMC 0,00064 % + 7,6 µV 10 V až 100 V CMC 0,00092 % + 97 µV 100 V až 1000 V CMC 0,00092 % + 1,4 mV KL-PM-0301 Napiecie stale / mierniki napiecia stalego Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,00081 % + 0,54 µV od 0,1 V do 1 V CMC 0,00064 % + 2,6 µV od 1 V do 10 V CMC 0,00064 % + 7,6 µV od 10 V do 100 V CMC 0,00092 % + 97 µV od 100 V do 1000 V CMC 0,00092 % + 1,4 mV Stejnosmerne napeti / meridla stejnosmerneho napeti Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 0 mV az 100 mV CMC 0,00081 % + 0,54 µV 0,1 V az 1 V CMC 0,00064 % + 2,6 µV 1 V az 10 V CMC 0,00064 % + 7,6 µV 10 V az 100 V CMC 0,00092 % + 97 µV 100 V az 1000 V CMC 0,00092 % + 1,4 mV KL-PM-0301","search_en":"DC voltage / DC voltage meters Calibration – electrical quantities Comparison with a reference multimeter 0 mV to 100 mV CMC 0,00081 % + 0,54 µV 0,1 V to 1 V CMC 0,00064 % + 2,6 µV 1 V to 10 V CMC 0,00064 % + 7,6 µV 10 V to 100 V CMC 0,00092 % + 97 µV 100 V to 1000 V CMC 0,00092 % + 1,4 mV KL-PM-0301","search_zh":"直流电压 / 直流电压表 校准 – 电学量 与标准万用表比较 0 mV 至 100 mV CMC 0,00081 % + 0,54 µV 0,1 V 至 1 V CMC 0,00064 % + 2,6 µV 1 V 至 10 V CMC 0,00064 % + 7,6 µV 10 V 至 100 V CMC 0,00092 % + 97 µV 100 V 至 1000 V CMC 0,00092 % + 1,4 mV KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"285e8da4d49952d11e8a0ed5","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"2","test_object":"Napięcie stałe / źródła napięcia stałego","test_object_en":"DC voltage / DC voltage sources","test_object_zh":"直流电压 / 直流电压源","test_object_cs":"Stejnosměrné napětí / zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,00081 % + 0,54 µV"},{"name":"","range":"od 0,1 V do 1 V","cmc":"0,00064 % + 2,6 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,00064 % + 7,6 µV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,00092 % + 97 µV"},{"name":"","range":"od 100 V do 1000 V","cmc":"0,00092 % + 1,4 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,00081 % + 0,54 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"0,00064 % + 2,6 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,00064 % + 7,6 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,00092 % + 97 µV"},{"name":"","range":"100 V to 1000 V","cmc":"0,00092 % + 1,4 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,00081 % + 0,54 µV"},{"name":"","range":"0,1 V 至 1 V","cmc":"0,00064 % + 2,6 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,00064 % + 7,6 µV"},{"name":"","range":"10 V 至 100 V","cmc":"0,00092 % + 97 µV"},{"name":"","range":"100 V 至 1000 V","cmc":"0,00092 % + 1,4 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,00081 % + 0,54 µV"},{"name":"","range":"0,1 V až 1 V","cmc":"0,00064 % + 2,6 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,00064 % + 7,6 µV"},{"name":"","range":"10 V až 100 V","cmc":"0,00092 % + 97 µV"},{"name":"","range":"100 V až 1000 V","cmc":"0,00092 % + 1,4 mV"}],"technique":"Pomiar multimetrem wzorcowym","technique_en":"Measurement by a reference multimeter","technique_zh":"用标准万用表测量","technique_cs":"Měření etalonovým multimetrem","techniques":["Pomiar multimetrem wzorcowym"],"techniques_en":["Measurement by a reference multimeter"],"techniques_zh":["用标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,00081 % + 0,54 µV\nod 0,1 V do 1 V CMC 0,00064 % + 2,6 µV\nod 1 V do 10 V CMC 0,00064 % + 7,6 µV\nod 10 V do 100 V CMC 0,00092 % + 97 µV\nod 100 V do 1000 V CMC 0,00092 % + 1,4 mV\nPomiar multimetrem wzorcowym","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / źródła napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym od 0 mV do 100 mV CMC 0,00081 % + 0,54 µV od 0,1 V do 1 V CMC 0,00064 % + 2,6 µV od 1 V do 10 V CMC 0,00064 % + 7,6 µV od 10 V do 100 V CMC 0,00092 % + 97 µV od 100 V do 1000 V CMC 0,00092 % + 1,4 mV Stejnosměrné napětí / zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Měření etalonovým multimetrem 0 mV až 100 mV CMC 0,00081 % + 0,54 µV 0,1 V až 1 V CMC 0,00064 % + 2,6 µV 1 V až 10 V CMC 0,00064 % + 7,6 µV 10 V až 100 V CMC 0,00092 % + 97 µV 100 V až 1000 V CMC 0,00092 % + 1,4 mV KL-PM-0301 Napiecie stale / zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym od 0 mV do 100 mV CMC 0,00081 % + 0,54 µV od 0,1 V do 1 V CMC 0,00064 % + 2,6 µV od 1 V do 10 V CMC 0,00064 % + 7,6 µV od 10 V do 100 V CMC 0,00092 % + 97 µV od 100 V do 1000 V CMC 0,00092 % + 1,4 mV Stejnosmerne napeti / zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Mereni etalonovym multimetrem 0 mV az 100 mV CMC 0,00081 % + 0,54 µV 0,1 V az 1 V CMC 0,00064 % + 2,6 µV 1 V az 10 V CMC 0,00064 % + 7,6 µV 10 V az 100 V CMC 0,00092 % + 97 µV 100 V az 1000 V CMC 0,00092 % + 1,4 mV KL-PM-0301","search_en":"DC voltage / DC voltage sources Calibration – electrical quantities Measurement by a reference multimeter 0 mV to 100 mV CMC 0,00081 % + 0,54 µV 0,1 V to 1 V CMC 0,00064 % + 2,6 µV 1 V to 10 V CMC 0,00064 % + 7,6 µV 10 V to 100 V CMC 0,00092 % + 97 µV 100 V to 1000 V CMC 0,00092 % + 1,4 mV KL-PM-0301","search_zh":"直流电压 / 直流电压源 校准 – 电学量 用标准万用表测量 0 mV 至 100 mV CMC 0,00081 % + 0,54 µV 0,1 V 至 1 V CMC 0,00064 % + 2,6 µV 1 V 至 10 V CMC 0,00064 % + 7,6 µV 10 V 至 100 V CMC 0,00092 % + 97 µV 100 V 至 1000 V CMC 0,00092 % + 1,4 mV KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3e384bea3c561349fb868a18","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / mierniki prądu stałego","test_object_en":"DC current / DC current meters","test_object_zh":"直流电流 / 直流电流表","test_object_cs":"Stejnosměrný proud / měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 1 µA","cmc":"0,033 % + 0,022 nA"},{"name":"","range":"od 1 µA do 10 µA","cmc":"0,0049 % + 0,14 nA"},{"name":"","range":"od 10 µA do 100 µA","cmc":"0,0012 % + 0,92 nA"},{"name":"","range":"od 0,1 mA do 1 mA","cmc":"0,0012 % + 9,2 nA"},{"name":"","range":"od 1 mA do 10 mA","cmc":"0,0015 % + 0,092 µA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,0049 % + 1,1 µA"},{"name":"","range":"od 0,1 A do 1 A","cmc":"0,025 % + 0,019 mA"},{"name":"","range":"od 1 A do 10 A","cmc":"0,058 % + 0,57 mA"},{"name":"","range":"od 10 A do 30 A","cmc":"0,080 % + 5,2 mA"}],"parameters_en":[{"name":"","range":"0 µA to 1 µA","cmc":"0,033 % + 0,022 nA"},{"name":"","range":"1 µA to 10 µA","cmc":"0,0049 % + 0,14 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"0,0012 % + 0,92 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"0,0012 % + 9,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,0015 % + 0,092 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,0049 % + 1,1 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"0,025 % + 0,019 mA"},{"name":"","range":"1 A to 10 A","cmc":"0,058 % + 0,57 mA"},{"name":"","range":"10 A to 30 A","cmc":"0,080 % + 5,2 mA"}],"parameters_zh":[{"name":"","range":"0 µA 至 1 µA","cmc":"0,033 % + 0,022 nA"},{"name":"","range":"1 µA 至 10 µA","cmc":"0,0049 % + 0,14 nA"},{"name":"","range":"10 µA 至 100 µA","cmc":"0,0012 % + 0,92 nA"},{"name":"","range":"0,1 mA 至 1 mA","cmc":"0,0012 % + 9,2 nA"},{"name":"","range":"1 mA 至 10 mA","cmc":"0,0015 % + 0,092 µA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,0049 % + 1,1 µA"},{"name":"","range":"0,1 A 至 1 A","cmc":"0,025 % + 0,019 mA"},{"name":"","range":"1 A 至 10 A","cmc":"0,058 % + 0,57 mA"},{"name":"","range":"10 A 至 30 A","cmc":"0,080 % + 5,2 mA"}],"parameters_cs":[{"name":"","range":"0 µA až 1 µA","cmc":"0,033 % + 0,022 nA"},{"name":"","range":"1 µA až 10 µA","cmc":"0,0049 % + 0,14 nA"},{"name":"","range":"10 µA až 100 µA","cmc":"0,0012 % + 0,92 nA"},{"name":"","range":"0,1 mA až 1 mA","cmc":"0,0012 % + 9,2 nA"},{"name":"","range":"1 mA až 10 mA","cmc":"0,0015 % + 0,092 µA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,0049 % + 1,1 µA"},{"name":"","range":"0,1 A až 1 A","cmc":"0,025 % + 0,019 mA"},{"name":"","range":"1 A až 10 A","cmc":"0,058 % + 0,57 mA"},{"name":"","range":"10 A až 30 A","cmc":"0,080 % + 5,2 mA"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 1 µA CMC 0,033 % + 0,022 nA\nod 1 µA do 10 µA CMC 0,0049 % + 0,14 nA\nod 10 µA do 100 µA CMC 0,0012 % + 0,92 nA\nod 0,1 mA do 1 mA CMC 0,0012 % + 9,2 nA\nod 1 mA do 10 mA CMC 0,0015 % + 0,092 µA\nod 10 mA do 100 mA CMC 0,0049 % + 1,1 µA\nod 0,1 A do 1 A CMC 0,025 % + 0,019 mA\nod 1 A do 10 A CMC 0,058 % + 0,57 mA\nod 10 A do 30 A CMC 0,080 % + 5,2 mA\nPorównanie z multimetrem wzorcowym","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki prądu stałego Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym od 0 µA do 1 µA CMC 0,033 % + 0,022 nA od 1 µA do 10 µA CMC 0,0049 % + 0,14 nA od 10 µA do 100 µA CMC 0,0012 % + 0,92 nA od 0,1 mA do 1 mA CMC 0,0012 % + 9,2 nA od 1 mA do 10 mA CMC 0,0015 % + 0,092 µA od 10 mA do 100 mA CMC 0,0049 % + 1,1 µA od 0,1 A do 1 A CMC 0,025 % + 0,019 mA od 1 A do 10 A CMC 0,058 % + 0,57 mA od 10 A do 30 A CMC 0,080 % + 5,2 mA Stejnosměrný proud / měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 0 µA až 1 µA CMC 0,033 % + 0,022 nA 1 µA až 10 µA CMC 0,0049 % + 0,14 nA 10 µA až 100 µA CMC 0,0012 % + 0,92 nA 0,1 mA až 1 mA CMC 0,0012 % + 9,2 nA 1 mA až 10 mA CMC 0,0015 % + 0,092 µA 10 mA až 100 mA CMC 0,0049 % + 1,1 µA 0,1 A až 1 A CMC 0,025 % + 0,019 mA 1 A až 10 A CMC 0,058 % + 0,57 mA 10 A až 30 A CMC 0,080 % + 5,2 mA KL-PM-0301 Prad staly / mierniki pradu stalego Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym od 0 µA do 1 µA CMC 0,033 % + 0,022 nA od 1 µA do 10 µA CMC 0,0049 % + 0,14 nA od 10 µA do 100 µA CMC 0,0012 % + 0,92 nA od 0,1 mA do 1 mA CMC 0,0012 % + 9,2 nA od 1 mA do 10 mA CMC 0,0015 % + 0,092 µA od 10 mA do 100 mA CMC 0,0049 % + 1,1 µA od 0,1 A do 1 A CMC 0,025 % + 0,019 mA od 1 A do 10 A CMC 0,058 % + 0,57 mA od 10 A do 30 A CMC 0,080 % + 5,2 mA Stejnosmerny proud / meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 0 µA az 1 µA CMC 0,033 % + 0,022 nA 1 µA az 10 µA CMC 0,0049 % + 0,14 nA 10 µA az 100 µA CMC 0,0012 % + 0,92 nA 0,1 mA az 1 mA CMC 0,0012 % + 9,2 nA 1 mA az 10 mA CMC 0,0015 % + 0,092 µA 10 mA az 100 mA CMC 0,0049 % + 1,1 µA 0,1 A az 1 A CMC 0,025 % + 0,019 mA 1 A az 10 A CMC 0,058 % + 0,57 mA 10 A az 30 A CMC 0,080 % + 5,2 mA KL-PM-0301","search_en":"DC current / DC current meters Calibration – electrical quantities Comparison with a reference multimeter 0 µA to 1 µA CMC 0,033 % + 0,022 nA 1 µA to 10 µA CMC 0,0049 % + 0,14 nA 10 µA to 100 µA CMC 0,0012 % + 0,92 nA 0,1 mA to 1 mA CMC 0,0012 % + 9,2 nA 1 mA to 10 mA CMC 0,0015 % + 0,092 µA 10 mA to 100 mA CMC 0,0049 % + 1,1 µA 0,1 A to 1 A CMC 0,025 % + 0,019 mA 1 A to 10 A CMC 0,058 % + 0,57 mA 10 A to 30 A CMC 0,080 % + 5,2 mA KL-PM-0301","search_zh":"直流电流 / 直流电流表 校准 – 电学量 与标准万用表比较 0 µA 至 1 µA CMC 0,033 % + 0,022 nA 1 µA 至 10 µA CMC 0,0049 % + 0,14 nA 10 µA 至 100 µA CMC 0,0012 % + 0,92 nA 0,1 mA 至 1 mA CMC 0,0012 % + 9,2 nA 1 mA 至 10 mA CMC 0,0015 % + 0,092 µA 10 mA 至 100 mA CMC 0,0049 % + 1,1 µA 0,1 A 至 1 A CMC 0,025 % + 0,019 mA 1 A 至 10 A CMC 0,058 % + 0,57 mA 10 A 至 30 A CMC 0,080 % + 5,2 mA KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43ec2ac525a98eb30650e4bc","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła prądu stałego","test_object_en":"DC current / DC current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 1 µA","cmc":"0,033 % + 0,022 nA"},{"name":"","range":"od 1 µA do 10 µA","cmc":"0,0049 % + 0,14 nA"},{"name":"","range":"od 10 µA do 100 µA","cmc":"0,0012 % + 0,92 nA"},{"name":"","range":"od 0,1 mA do 1 mA","cmc":"0,0012 % + 9,2 nA"},{"name":"","range":"od 1 mA do 10 mA","cmc":"0,0015 % + 0,092 µA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,0049 % + 1,1 µA"},{"name":"","range":"od 0,1 A do 1 A","cmc":"0,025 % + 0,019 mA"},{"name":"","range":"od 1 A do 10 A","cmc":"0,058 % + 0,57 mA"},{"name":"","range":"od 10 A do 30 A","cmc":"0,080 % + 5,2 mA"}],"parameters_en":[{"name":"","range":"0 µA to 1 µA","cmc":"0,033 % + 0,022 nA"},{"name":"","range":"1 µA to 10 µA","cmc":"0,0049 % + 0,14 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"0,0012 % + 0,92 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"0,0012 % + 9,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,0015 % + 0,092 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,0049 % + 1,1 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"0,025 % + 0,019 mA"},{"name":"","range":"1 A to 10 A","cmc":"0,058 % + 0,57 mA"},{"name":"","range":"10 A to 30 A","cmc":"0,080 % + 5,2 mA"}],"parameters_zh":[{"name":"","range":"0 µA 至 1 µA","cmc":"0,033 % + 0,022 nA"},{"name":"","range":"1 µA 至 10 µA","cmc":"0,0049 % + 0,14 nA"},{"name":"","range":"10 µA 至 100 µA","cmc":"0,0012 % + 0,92 nA"},{"name":"","range":"0,1 mA 至 1 mA","cmc":"0,0012 % + 9,2 nA"},{"name":"","range":"1 mA 至 10 mA","cmc":"0,0015 % + 0,092 µA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,0049 % + 1,1 µA"},{"name":"","range":"0,1 A 至 1 A","cmc":"0,025 % + 0,019 mA"},{"name":"","range":"1 A 至 10 A","cmc":"0,058 % + 0,57 mA"},{"name":"","range":"10 A 至 30 A","cmc":"0,080 % + 5,2 mA"}],"parameters_cs":[{"name":"","range":"0 µA až 1 µA","cmc":"0,033 % + 0,022 nA"},{"name":"","range":"1 µA až 10 µA","cmc":"0,0049 % + 0,14 nA"},{"name":"","range":"10 µA až 100 µA","cmc":"0,0012 % + 0,92 nA"},{"name":"","range":"0,1 mA až 1 mA","cmc":"0,0012 % + 9,2 nA"},{"name":"","range":"1 mA až 10 mA","cmc":"0,0015 % + 0,092 µA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,0049 % + 1,1 µA"},{"name":"","range":"0,1 A až 1 A","cmc":"0,025 % + 0,019 mA"},{"name":"","range":"1 A až 10 A","cmc":"0,058 % + 0,57 mA"},{"name":"","range":"10 A až 30 A","cmc":"0,080 % + 5,2 mA"}],"technique":"Pomiar multimetrem wzorcowym","technique_en":"Measurement by a reference multimeter","technique_zh":"用标准万用表测量","technique_cs":"Měření etalonovým multimetrem","techniques":["Pomiar multimetrem wzorcowym"],"techniques_en":["Measurement by a reference multimeter"],"techniques_zh":["用标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 1 µA CMC 0,033 % + 0,022 nA\nod 1 µA do 10 µA CMC 0,0049 % + 0,14 nA\nod 10 µA do 100 µA CMC 0,0012 % + 0,92 nA\nod 0,1 mA do 1 mA CMC 0,0012 % + 9,2 nA\nod 1 mA do 10 mA CMC 0,0015 % + 0,092 µA\nod 10 mA do 100 mA CMC 0,0049 % + 1,1 µA\nod 0,1 A do 1 A CMC 0,025 % + 0,019 mA\nod 1 A do 10 A CMC 0,058 % + 0,57 mA\nod 10 A do 30 A CMC 0,080 % + 5,2 mA\nPomiar multimetrem wzorcowym","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym od 0 µA do 1 µA CMC 0,033 % + 0,022 nA od 1 µA do 10 µA CMC 0,0049 % + 0,14 nA od 10 µA do 100 µA CMC 0,0012 % + 0,92 nA od 0,1 mA do 1 mA CMC 0,0012 % + 9,2 nA od 1 mA do 10 mA CMC 0,0015 % + 0,092 µA od 10 mA do 100 mA CMC 0,0049 % + 1,1 µA od 0,1 A do 1 A CMC 0,025 % + 0,019 mA od 1 A do 10 A CMC 0,058 % + 0,57 mA od 10 A do 30 A CMC 0,080 % + 5,2 mA Stejnosměrný proud / zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Měření etalonovým multimetrem 0 µA až 1 µA CMC 0,033 % + 0,022 nA 1 µA až 10 µA CMC 0,0049 % + 0,14 nA 10 µA až 100 µA CMC 0,0012 % + 0,92 nA 0,1 mA až 1 mA CMC 0,0012 % + 9,2 nA 1 mA až 10 mA CMC 0,0015 % + 0,092 µA 10 mA až 100 mA CMC 0,0049 % + 1,1 µA 0,1 A až 1 A CMC 0,025 % + 0,019 mA 1 A až 10 A CMC 0,058 % + 0,57 mA 10 A až 30 A CMC 0,080 % + 5,2 mA KL-PM-0301 Prad staly / zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym od 0 µA do 1 µA CMC 0,033 % + 0,022 nA od 1 µA do 10 µA CMC 0,0049 % + 0,14 nA od 10 µA do 100 µA CMC 0,0012 % + 0,92 nA od 0,1 mA do 1 mA CMC 0,0012 % + 9,2 nA od 1 mA do 10 mA CMC 0,0015 % + 0,092 µA od 10 mA do 100 mA CMC 0,0049 % + 1,1 µA od 0,1 A do 1 A CMC 0,025 % + 0,019 mA od 1 A do 10 A CMC 0,058 % + 0,57 mA od 10 A do 30 A CMC 0,080 % + 5,2 mA Stejnosmerny proud / zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Mereni etalonovym multimetrem 0 µA az 1 µA CMC 0,033 % + 0,022 nA 1 µA az 10 µA CMC 0,0049 % + 0,14 nA 10 µA az 100 µA CMC 0,0012 % + 0,92 nA 0,1 mA az 1 mA CMC 0,0012 % + 9,2 nA 1 mA az 10 mA CMC 0,0015 % + 0,092 µA 10 mA az 100 mA CMC 0,0049 % + 1,1 µA 0,1 A az 1 A CMC 0,025 % + 0,019 mA 1 A az 10 A CMC 0,058 % + 0,57 mA 10 A az 30 A CMC 0,080 % + 5,2 mA KL-PM-0301","search_en":"DC current / DC current sources Calibration – electrical quantities Measurement by a reference multimeter 0 µA to 1 µA CMC 0,033 % + 0,022 nA 1 µA to 10 µA CMC 0,0049 % + 0,14 nA 10 µA to 100 µA CMC 0,0012 % + 0,92 nA 0,1 mA to 1 mA CMC 0,0012 % + 9,2 nA 1 mA to 10 mA CMC 0,0015 % + 0,092 µA 10 mA to 100 mA CMC 0,0049 % + 1,1 µA 0,1 A to 1 A CMC 0,025 % + 0,019 mA 1 A to 10 A CMC 0,058 % + 0,57 mA 10 A to 30 A CMC 0,080 % + 5,2 mA KL-PM-0301","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用标准万用表测量 0 µA 至 1 µA CMC 0,033 % + 0,022 nA 1 µA 至 10 µA CMC 0,0049 % + 0,14 nA 10 µA 至 100 µA CMC 0,0012 % + 0,92 nA 0,1 mA 至 1 mA CMC 0,0012 % + 9,2 nA 1 mA 至 10 mA CMC 0,0015 % + 0,092 µA 10 mA 至 100 mA CMC 0,0049 % + 1,1 µA 0,1 A 至 1 A CMC 0,025 % + 0,019 mA 1 A 至 10 A CMC 0,058 % + 0,57 mA 10 A 至 30 A CMC 0,080 % + 5,2 mA KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1f1c400cab3d50001d01f422","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"4","test_object":"Napięcie przemienne / mierniki napięcia przemiennego","test_object_en":"AC voltage / AC voltage meters","test_object_zh":"交流电压 / 交流电压表","test_object_cs":"Střídavé napětí / měřidla střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 100 kHz","range":"od 0 mV do 100 mV","cmc":"0,028 % + 32 µV"},{"name":"10 Hz do 100 kHz","range":"od 0,1 V do 1 V","cmc":"0,025 % + 0,14 mV"},{"name":"10 Hz do 100 kHz","range":"od 1 V do 10 V","cmc":"0,025 % + 1,4 mV"},{"name":"10 Hz do 50 kHz","range":"od 10 V do 100 V","cmc":"0,029 % + 28 mV"},{"name":"10 Hz do 10 kHz","range":"od 100 V do 1000 V","cmc":"0,029 % + 0,36 V"}],"parameters_en":[{"name":"10 Hz to 100 kHz","range":"0 mV to 100 mV","cmc":"0,028 % + 32 µV"},{"name":"10 Hz to 100 kHz","range":"0,1 V to 1 V","cmc":"0,025 % + 0,14 mV"},{"name":"10 Hz to 100 kHz","range":"1 V to 10 V","cmc":"0,025 % + 1,4 mV"},{"name":"10 Hz to 50 kHz","range":"10 V to 100 V","cmc":"0,029 % + 28 mV"},{"name":"10 Hz to 10 kHz","range":"100 V to 1000 V","cmc":"0,029 % + 0,36 V"}],"parameters_zh":[{"name":"10 Hz 至 100 kHz","range":"0 mV 至 100 mV","cmc":"0,028 % + 32 µV"},{"name":"10 Hz 至 100 kHz","range":"0,1 V 至 1 V","cmc":"0,025 % + 0,14 mV"},{"name":"10 Hz 至 100 kHz","range":"1 V 至 10 V","cmc":"0,025 % + 1,4 mV"},{"name":"10 Hz 至 50 kHz","range":"10 V 至 100 V","cmc":"0,029 % + 28 mV"},{"name":"10 Hz 至 10 kHz","range":"100 V 至 1000 V","cmc":"0,029 % + 0,36 V"}],"parameters_cs":[{"name":"10 Hz až 100 kHz","range":"0 mV až 100 mV","cmc":"0,028 % + 32 µV"},{"name":"10 Hz až 100 kHz","range":"0,1 V až 1 V","cmc":"0,025 % + 0,14 mV"},{"name":"10 Hz až 100 kHz","range":"1 V až 10 V","cmc":"0,025 % + 1,4 mV"},{"name":"10 Hz až 50 kHz","range":"10 V až 100 V","cmc":"0,029 % + 28 mV"},{"name":"10 Hz až 10 kHz","range":"100 V až 1000 V","cmc":"0,029 % + 0,36 V"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 100 kHz od 0 mV do 100 mV CMC 0,028 % + 32 µV\n10 Hz do 100 kHz od 0,1 V do 1 V CMC 0,025 % + 0,14 mV\n10 Hz do 100 kHz od 1 V do 10 V CMC 0,025 % + 1,4 mV\n10 Hz do 50 kHz od 10 V do 100 V CMC 0,029 % + 28 mV\n10 Hz do 10 kHz od 100 V do 1000 V CMC 0,029 % + 0,36 V\nPorównanie z multimetrem wzorcowym","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / mierniki napięcia przemiennego Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym 10 Hz do 100 kHz od 0 mV do 100 mV CMC 0,028 % + 32 µV 10 Hz do 100 kHz od 0,1 V do 1 V CMC 0,025 % + 0,14 mV 10 Hz do 100 kHz od 1 V do 10 V CMC 0,025 % + 1,4 mV 10 Hz do 50 kHz od 10 V do 100 V CMC 0,029 % + 28 mV 10 Hz do 10 kHz od 100 V do 1000 V CMC 0,029 % + 0,36 V Střídavé napětí / měřidla střídavého napětí Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 10 Hz až 100 kHz 0 mV až 100 mV CMC 0,028 % + 32 µV 10 Hz až 100 kHz 0,1 V až 1 V CMC 0,025 % + 0,14 mV 10 Hz až 100 kHz 1 V až 10 V CMC 0,025 % + 1,4 mV 10 Hz až 50 kHz 10 V až 100 V CMC 0,029 % + 28 mV 10 Hz až 10 kHz 100 V až 1000 V CMC 0,029 % + 0,36 V KL-PM-0301 Napiecie przemienne / mierniki napiecia przemiennego Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym 10 Hz do 100 kHz od 0 mV do 100 mV CMC 0,028 % + 32 µV 10 Hz do 100 kHz od 0,1 V do 1 V CMC 0,025 % + 0,14 mV 10 Hz do 100 kHz od 1 V do 10 V CMC 0,025 % + 1,4 mV 10 Hz do 50 kHz od 10 V do 100 V CMC 0,029 % + 28 mV 10 Hz do 10 kHz od 100 V do 1000 V CMC 0,029 % + 0,36 V Stridave napeti / meridla stridaveho napeti Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 10 Hz az 100 kHz 0 mV az 100 mV CMC 0,028 % + 32 µV 10 Hz az 100 kHz 0,1 V az 1 V CMC 0,025 % + 0,14 mV 10 Hz az 100 kHz 1 V az 10 V CMC 0,025 % + 1,4 mV 10 Hz az 50 kHz 10 V az 100 V CMC 0,029 % + 28 mV 10 Hz az 10 kHz 100 V az 1000 V CMC 0,029 % + 0,36 V KL-PM-0301","search_en":"AC voltage / AC voltage meters Calibration – electrical quantities Comparison with a reference multimeter 10 Hz to 100 kHz 0 mV to 100 mV CMC 0,028 % + 32 µV 10 Hz to 100 kHz 0,1 V to 1 V CMC 0,025 % + 0,14 mV 10 Hz to 100 kHz 1 V to 10 V CMC 0,025 % + 1,4 mV 10 Hz to 50 kHz 10 V to 100 V CMC 0,029 % + 28 mV 10 Hz to 10 kHz 100 V to 1000 V CMC 0,029 % + 0,36 V KL-PM-0301","search_zh":"交流电压 / 交流电压表 校准 – 电学量 与标准万用表比较 10 Hz 至 100 kHz 0 mV 至 100 mV CMC 0,028 % + 32 µV 10 Hz 至 100 kHz 0,1 V 至 1 V CMC 0,025 % + 0,14 mV 10 Hz 至 100 kHz 1 V 至 10 V CMC 0,025 % + 1,4 mV 10 Hz 至 50 kHz 10 V 至 100 V CMC 0,029 % + 28 mV 10 Hz 至 10 kHz 100 V 至 1000 V CMC 0,029 % + 0,36 V KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b9785cde427d2fd1311559a2","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"4","test_object":"Napięcie przemienne / źródła napięcia przemiennego","test_object_en":"AC voltage / AC voltage sources","test_object_zh":"交流电压 / 交流电压源","test_object_cs":"Střídavé napětí / zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 100 kHz","range":"od 0 mV do 100 mV","cmc":"0,028 % + 32 µV"},{"name":"10 Hz do 100 kHz","range":"od 0,1 V do 1 V","cmc":"0,025 % + 0,14 mV"},{"name":"10 Hz do 100 kHz","range":"od 1 V do 10 V","cmc":"0,025 % + 1,4 mV"},{"name":"10 Hz do 50 kHz","range":"od 10 V do 100 V","cmc":"0,029 % + 28 mV"},{"name":"10 Hz do 10 kHz","range":"od 100 V do 1000 V","cmc":"0,029 % + 0,36 V"}],"parameters_en":[{"name":"10 Hz to 100 kHz","range":"0 mV to 100 mV","cmc":"0,028 % + 32 µV"},{"name":"10 Hz to 100 kHz","range":"0,1 V to 1 V","cmc":"0,025 % + 0,14 mV"},{"name":"10 Hz to 100 kHz","range":"1 V to 10 V","cmc":"0,025 % + 1,4 mV"},{"name":"10 Hz to 50 kHz","range":"10 V to 100 V","cmc":"0,029 % + 28 mV"},{"name":"10 Hz to 10 kHz","range":"100 V to 1000 V","cmc":"0,029 % + 0,36 V"}],"parameters_zh":[{"name":"10 Hz 至 100 kHz","range":"0 mV 至 100 mV","cmc":"0,028 % + 32 µV"},{"name":"10 Hz 至 100 kHz","range":"0,1 V 至 1 V","cmc":"0,025 % + 0,14 mV"},{"name":"10 Hz 至 100 kHz","range":"1 V 至 10 V","cmc":"0,025 % + 1,4 mV"},{"name":"10 Hz 至 50 kHz","range":"10 V 至 100 V","cmc":"0,029 % + 28 mV"},{"name":"10 Hz 至 10 kHz","range":"100 V 至 1000 V","cmc":"0,029 % + 0,36 V"}],"parameters_cs":[{"name":"10 Hz až 100 kHz","range":"0 mV až 100 mV","cmc":"0,028 % + 32 µV"},{"name":"10 Hz až 100 kHz","range":"0,1 V až 1 V","cmc":"0,025 % + 0,14 mV"},{"name":"10 Hz až 100 kHz","range":"1 V až 10 V","cmc":"0,025 % + 1,4 mV"},{"name":"10 Hz až 50 kHz","range":"10 V až 100 V","cmc":"0,029 % + 28 mV"},{"name":"10 Hz až 10 kHz","range":"100 V až 1000 V","cmc":"0,029 % + 0,36 V"}],"technique":"Pomiar multimetrem wzorcowym","technique_en":"Measurement by a reference multimeter","technique_zh":"用标准万用表测量","technique_cs":"Měření etalonovým multimetrem","techniques":["Pomiar multimetrem wzorcowym"],"techniques_en":["Measurement by a reference multimeter"],"techniques_zh":["用标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 100 kHz od 0 mV do 100 mV CMC 0,028 % + 32 µV\n10 Hz do 100 kHz od 0,1 V do 1 V CMC 0,025 % + 0,14 mV\n10 Hz do 100 kHz od 1 V do 10 V CMC 0,025 % + 1,4 mV\n10 Hz do 50 kHz od 10 V do 100 V CMC 0,029 % + 28 mV\n10 Hz do 10 kHz od 100 V do 1000 V CMC 0,029 % + 0,36 V\nPomiar multimetrem wzorcowym","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym 10 Hz do 100 kHz od 0 mV do 100 mV CMC 0,028 % + 32 µV 10 Hz do 100 kHz od 0,1 V do 1 V CMC 0,025 % + 0,14 mV 10 Hz do 100 kHz od 1 V do 10 V CMC 0,025 % + 1,4 mV 10 Hz do 50 kHz od 10 V do 100 V CMC 0,029 % + 28 mV 10 Hz do 10 kHz od 100 V do 1000 V CMC 0,029 % + 0,36 V Střídavé napětí / zdroje střídavého napětí Kalibrace – elektrické veličiny Měření etalonovým multimetrem 10 Hz až 100 kHz 0 mV až 100 mV CMC 0,028 % + 32 µV 10 Hz až 100 kHz 0,1 V až 1 V CMC 0,025 % + 0,14 mV 10 Hz až 100 kHz 1 V až 10 V CMC 0,025 % + 1,4 mV 10 Hz až 50 kHz 10 V až 100 V CMC 0,029 % + 28 mV 10 Hz až 10 kHz 100 V až 1000 V CMC 0,029 % + 0,36 V KL-PM-0301 Napiecie przemienne / zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym 10 Hz do 100 kHz od 0 mV do 100 mV CMC 0,028 % + 32 µV 10 Hz do 100 kHz od 0,1 V do 1 V CMC 0,025 % + 0,14 mV 10 Hz do 100 kHz od 1 V do 10 V CMC 0,025 % + 1,4 mV 10 Hz do 50 kHz od 10 V do 100 V CMC 0,029 % + 28 mV 10 Hz do 10 kHz od 100 V do 1000 V CMC 0,029 % + 0,36 V Stridave napeti / zdroje stridaveho napeti Kalibrace – elektricke veliciny Mereni etalonovym multimetrem 10 Hz az 100 kHz 0 mV az 100 mV CMC 0,028 % + 32 µV 10 Hz az 100 kHz 0,1 V az 1 V CMC 0,025 % + 0,14 mV 10 Hz az 100 kHz 1 V az 10 V CMC 0,025 % + 1,4 mV 10 Hz az 50 kHz 10 V az 100 V CMC 0,029 % + 28 mV 10 Hz az 10 kHz 100 V az 1000 V CMC 0,029 % + 0,36 V KL-PM-0301","search_en":"AC voltage / AC voltage sources Calibration – electrical quantities Measurement by a reference multimeter 10 Hz to 100 kHz 0 mV to 100 mV CMC 0,028 % + 32 µV 10 Hz to 100 kHz 0,1 V to 1 V CMC 0,025 % + 0,14 mV 10 Hz to 100 kHz 1 V to 10 V CMC 0,025 % + 1,4 mV 10 Hz to 50 kHz 10 V to 100 V CMC 0,029 % + 28 mV 10 Hz to 10 kHz 100 V to 1000 V CMC 0,029 % + 0,36 V KL-PM-0301","search_zh":"交流电压 / 交流电压源 校准 – 电学量 用标准万用表测量 10 Hz 至 100 kHz 0 mV 至 100 mV CMC 0,028 % + 32 µV 10 Hz 至 100 kHz 0,1 V 至 1 V CMC 0,025 % + 0,14 mV 10 Hz 至 100 kHz 1 V 至 10 V CMC 0,025 % + 1,4 mV 10 Hz 至 50 kHz 10 V 至 100 V CMC 0,029 % + 28 mV 10 Hz 至 10 kHz 100 V 至 1000 V CMC 0,029 % + 0,36 V KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"16e441abd457ddbf983581f1","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / mierniki prądu przemiennego","test_object_en":"AC current / AC current meters","test_object_zh":"交流电流 / 交流电流表","test_object_cs":"Střídavý proud / měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 2 kHz","range":"od 1 µA do 100 µA","cmc":"0,049 % + 25 nA"},{"name":"20 Hz do 10 kHz","range":"od 0,1 mA do 1 mA","cmc":"0,049 % + 0,24 µA"},{"name":"20 Hz do 10 kHz","range":"od 1 mA do 10 mA","cmc":"0,049 % + 2,4 µA"},{"name":"20 Hz do 10 kHz","range":"od 10 mA do 100 mA","cmc":"0,049 % + 24 µA"},{"name":"20 Hz do 10 kHz","range":"od 0,1 do 1 A","cmc":"0,065 % +0,26 mA"},{"name":"20 Hz do 1 kHz","range":"od 1 do 10 A","cmc":"0,12 % + 43 mA"},{"name":"20 Hz do 1 kHz","range":"od 10 do 30 A","cmc":"0,12 % + 131 mA"}],"parameters_en":[{"name":"20 Hz to 2 kHz","range":"1 µA to 100 µA","cmc":"0,049 % + 25 nA"},{"name":"20 Hz to 10 kHz","range":"0,1 mA to 1 mA","cmc":"0,049 % + 0,24 µA"},{"name":"20 Hz to 10 kHz","range":"1 mA to 10 mA","cmc":"0,049 % + 2,4 µA"},{"name":"20 Hz to 10 kHz","range":"10 mA to 100 mA","cmc":"0,049 % + 24 µA"},{"name":"20 Hz to 10 kHz","range":"0,1 to 1 A","cmc":"0,065 % +0,26 mA"},{"name":"20 Hz to 1 kHz","range":"1 to 10 A","cmc":"0,12 % + 43 mA"},{"name":"20 Hz to 1 kHz","range":"10 to 30 A","cmc":"0,12 % + 131 mA"}],"parameters_zh":[{"name":"20 Hz 至 2 kHz","range":"1 µA 至 100 µA","cmc":"0,049 % + 25 nA"},{"name":"20 Hz 至 10 kHz","range":"0,1 mA 至 1 mA","cmc":"0,049 % + 0,24 µA"},{"name":"20 Hz 至 10 kHz","range":"1 mA 至 10 mA","cmc":"0,049 % + 2,4 µA"},{"name":"20 Hz 至 10 kHz","range":"10 mA 至 100 mA","cmc":"0,049 % + 24 µA"},{"name":"20 Hz 至 10 kHz","range":"0,1 至 1 A","cmc":"0,065 % +0,26 mA"},{"name":"20 Hz 至 1 kHz","range":"1 至 10 A","cmc":"0,12 % + 43 mA"},{"name":"20 Hz 至 1 kHz","range":"10 至 30 A","cmc":"0,12 % + 131 mA"}],"parameters_cs":[{"name":"20 Hz až 2 kHz","range":"1 µA až 100 µA","cmc":"0,049 % + 25 nA"},{"name":"20 Hz až 10 kHz","range":"0,1 mA až 1 mA","cmc":"0,049 % + 0,24 µA"},{"name":"20 Hz až 10 kHz","range":"1 mA až 10 mA","cmc":"0,049 % + 2,4 µA"},{"name":"20 Hz až 10 kHz","range":"10 mA až 100 mA","cmc":"0,049 % + 24 µA"},{"name":"20 Hz až 10 kHz","range":"0,1 až 1 A","cmc":"0,065 % +0,26 mA"},{"name":"20 Hz až 1 kHz","range":"1 až 10 A","cmc":"0,12 % + 43 mA"},{"name":"20 Hz až 1 kHz","range":"10 až 30 A","cmc":"0,12 % + 131 mA"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 Hz do 2 kHz od 1 µA do 100 µA CMC 0,049 % + 25 nA\n20 Hz do 10 kHz od 0,1 mA do 1 mA CMC 0,049 % + 0,24 µA\n20 Hz do 10 kHz od 1 mA do 10 mA CMC 0,049 % + 2,4 µA\n20 Hz do 10 kHz od 10 mA do 100 mA CMC 0,049 % + 24 µA\n20 Hz do 10 kHz od 0,1 do 1 A CMC 0,065 % +0,26 mA\n20 Hz do 1 kHz od 1 do 10 A CMC 0,12 % + 43 mA\n20 Hz do 1 kHz od 10 do 30 A CMC 0,12 % + 131 mA\nPorównanie z multimetrem wzorcowym","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki prądu przemiennego Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym 20 Hz do 2 kHz od 1 µA do 100 µA CMC 0,049 % + 25 nA 20 Hz do 10 kHz od 0,1 mA do 1 mA CMC 0,049 % + 0,24 µA 20 Hz do 10 kHz od 1 mA do 10 mA CMC 0,049 % + 2,4 µA 20 Hz do 10 kHz od 10 mA do 100 mA CMC 0,049 % + 24 µA 20 Hz do 10 kHz od 0,1 do 1 A CMC 0,065 % +0,26 mA 20 Hz do 1 kHz od 1 do 10 A CMC 0,12 % + 43 mA 20 Hz do 1 kHz od 10 do 30 A CMC 0,12 % + 131 mA Střídavý proud / měřidla střídavého proudu Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 20 Hz až 2 kHz 1 µA až 100 µA CMC 0,049 % + 25 nA 20 Hz až 10 kHz 0,1 mA až 1 mA CMC 0,049 % + 0,24 µA 20 Hz až 10 kHz 1 mA až 10 mA CMC 0,049 % + 2,4 µA 20 Hz až 10 kHz 10 mA až 100 mA CMC 0,049 % + 24 µA 20 Hz až 10 kHz 0,1 až 1 A CMC 0,065 % +0,26 mA 20 Hz až 1 kHz 1 až 10 A CMC 0,12 % + 43 mA 20 Hz až 1 kHz 10 až 30 A CMC 0,12 % + 131 mA KL-PM-0301 Prad przemienny / mierniki pradu przemiennego Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym 20 Hz do 2 kHz od 1 µA do 100 µA CMC 0,049 % + 25 nA 20 Hz do 10 kHz od 0,1 mA do 1 mA CMC 0,049 % + 0,24 µA 20 Hz do 10 kHz od 1 mA do 10 mA CMC 0,049 % + 2,4 µA 20 Hz do 10 kHz od 10 mA do 100 mA CMC 0,049 % + 24 µA 20 Hz do 10 kHz od 0,1 do 1 A CMC 0,065 % +0,26 mA 20 Hz do 1 kHz od 1 do 10 A CMC 0,12 % + 43 mA 20 Hz do 1 kHz od 10 do 30 A CMC 0,12 % + 131 mA Stridavy proud / meridla stridaveho proudu Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 20 Hz az 2 kHz 1 µA az 100 µA CMC 0,049 % + 25 nA 20 Hz az 10 kHz 0,1 mA az 1 mA CMC 0,049 % + 0,24 µA 20 Hz az 10 kHz 1 mA az 10 mA CMC 0,049 % + 2,4 µA 20 Hz az 10 kHz 10 mA az 100 mA CMC 0,049 % + 24 µA 20 Hz az 10 kHz 0,1 az 1 A CMC 0,065 % +0,26 mA 20 Hz az 1 kHz 1 az 10 A CMC 0,12 % + 43 mA 20 Hz az 1 kHz 10 az 30 A CMC 0,12 % + 131 mA KL-PM-0301","search_en":"AC current / AC current meters Calibration – electrical quantities Comparison with a reference multimeter 20 Hz to 2 kHz 1 µA to 100 µA CMC 0,049 % + 25 nA 20 Hz to 10 kHz 0,1 mA to 1 mA CMC 0,049 % + 0,24 µA 20 Hz to 10 kHz 1 mA to 10 mA CMC 0,049 % + 2,4 µA 20 Hz to 10 kHz 10 mA to 100 mA CMC 0,049 % + 24 µA 20 Hz to 10 kHz 0,1 to 1 A CMC 0,065 % +0,26 mA 20 Hz to 1 kHz 1 to 10 A CMC 0,12 % + 43 mA 20 Hz to 1 kHz 10 to 30 A CMC 0,12 % + 131 mA KL-PM-0301","search_zh":"交流电流 / 交流电流表 校准 – 电学量 与标准万用表比较 20 Hz 至 2 kHz 1 µA 至 100 µA CMC 0,049 % + 25 nA 20 Hz 至 10 kHz 0,1 mA 至 1 mA CMC 0,049 % + 0,24 µA 20 Hz 至 10 kHz 1 mA 至 10 mA CMC 0,049 % + 2,4 µA 20 Hz 至 10 kHz 10 mA 至 100 mA CMC 0,049 % + 24 µA 20 Hz 至 10 kHz 0,1 至 1 A CMC 0,065 % +0,26 mA 20 Hz 至 1 kHz 1 至 10 A CMC 0,12 % + 43 mA 20 Hz 至 1 kHz 10 至 30 A CMC 0,12 % + 131 mA KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"235cb79d6ecd1f51415a4101","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / źródła prądu przemiennego","test_object_en":"AC current / AC current sources","test_object_zh":"交流电流 / 交流电流源","test_object_cs":"Střídavý proud / zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 2 kHz","range":"od 1 µA do 100 µA","cmc":"0,049 % + 25 nA"},{"name":"20 Hz do 10 kHz","range":"od 0,1 mA do 1 mA","cmc":"0,049 % + 0,24 µA"},{"name":"20 Hz do 10 kHz","range":"od 1 mA do 10 mA","cmc":"0,049 % + 2,4 µA"},{"name":"20 Hz do 10 kHz","range":"od 10 mA do 100 mA","cmc":"0,049 % + 24 µA"},{"name":"20 Hz do 10 kHz","range":"od 0,1 do 1 A","cmc":"0,065 % +0,26 mA"},{"name":"20 Hz do 1 kHz","range":"od 1 do 10 A","cmc":"0,12 % + 43 mA"},{"name":"20 Hz do 1 kHz","range":"od 10 do 30 A","cmc":"0,12 % + 131 mA"}],"parameters_en":[{"name":"20 Hz to 2 kHz","range":"1 µA to 100 µA","cmc":"0,049 % + 25 nA"},{"name":"20 Hz to 10 kHz","range":"0,1 mA to 1 mA","cmc":"0,049 % + 0,24 µA"},{"name":"20 Hz to 10 kHz","range":"1 mA to 10 mA","cmc":"0,049 % + 2,4 µA"},{"name":"20 Hz to 10 kHz","range":"10 mA to 100 mA","cmc":"0,049 % + 24 µA"},{"name":"20 Hz to 10 kHz","range":"0,1 to 1 A","cmc":"0,065 % +0,26 mA"},{"name":"20 Hz to 1 kHz","range":"1 to 10 A","cmc":"0,12 % + 43 mA"},{"name":"20 Hz to 1 kHz","range":"10 to 30 A","cmc":"0,12 % + 131 mA"}],"parameters_zh":[{"name":"20 Hz 至 2 kHz","range":"1 µA 至 100 µA","cmc":"0,049 % + 25 nA"},{"name":"20 Hz 至 10 kHz","range":"0,1 mA 至 1 mA","cmc":"0,049 % + 0,24 µA"},{"name":"20 Hz 至 10 kHz","range":"1 mA 至 10 mA","cmc":"0,049 % + 2,4 µA"},{"name":"20 Hz 至 10 kHz","range":"10 mA 至 100 mA","cmc":"0,049 % + 24 µA"},{"name":"20 Hz 至 10 kHz","range":"0,1 至 1 A","cmc":"0,065 % +0,26 mA"},{"name":"20 Hz 至 1 kHz","range":"1 至 10 A","cmc":"0,12 % + 43 mA"},{"name":"20 Hz 至 1 kHz","range":"10 至 30 A","cmc":"0,12 % + 131 mA"}],"parameters_cs":[{"name":"20 Hz až 2 kHz","range":"1 µA až 100 µA","cmc":"0,049 % + 25 nA"},{"name":"20 Hz až 10 kHz","range":"0,1 mA až 1 mA","cmc":"0,049 % + 0,24 µA"},{"name":"20 Hz až 10 kHz","range":"1 mA až 10 mA","cmc":"0,049 % + 2,4 µA"},{"name":"20 Hz až 10 kHz","range":"10 mA až 100 mA","cmc":"0,049 % + 24 µA"},{"name":"20 Hz až 10 kHz","range":"0,1 až 1 A","cmc":"0,065 % +0,26 mA"},{"name":"20 Hz až 1 kHz","range":"1 až 10 A","cmc":"0,12 % + 43 mA"},{"name":"20 Hz až 1 kHz","range":"10 až 30 A","cmc":"0,12 % + 131 mA"}],"technique":"Pomiar z multimetrem wzorcowym","technique_en":"Measurement by a reference multimeter","technique_zh":"用标准万用表测量","technique_cs":"Měření s etalonovým multimetrem","techniques":["Pomiar z multimetrem wzorcowym"],"techniques_en":["Measurement by a reference multimeter"],"techniques_zh":["用标准万用表测量"],"techniques_cs":["Měření s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 Hz do 2 kHz od 1 µA do 100 µA CMC 0,049 % + 25 nA\n20 Hz do 10 kHz od 0,1 mA do 1 mA CMC 0,049 % + 0,24 µA\n20 Hz do 10 kHz od 1 mA do 10 mA CMC 0,049 % + 2,4 µA\n20 Hz do 10 kHz od 10 mA do 100 mA CMC 0,049 % + 24 µA\n20 Hz do 10 kHz od 0,1 do 1 A CMC 0,065 % +0,26 mA\n20 Hz do 1 kHz od 1 do 10 A CMC 0,12 % + 43 mA\n20 Hz do 1 kHz od 10 do 30 A CMC 0,12 % + 131 mA\nPomiar z multimetrem wzorcowym","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar z multimetrem wzorcowym 20 Hz do 2 kHz od 1 µA do 100 µA CMC 0,049 % + 25 nA 20 Hz do 10 kHz od 0,1 mA do 1 mA CMC 0,049 % + 0,24 µA 20 Hz do 10 kHz od 1 mA do 10 mA CMC 0,049 % + 2,4 µA 20 Hz do 10 kHz od 10 mA do 100 mA CMC 0,049 % + 24 µA 20 Hz do 10 kHz od 0,1 do 1 A CMC 0,065 % +0,26 mA 20 Hz do 1 kHz od 1 do 10 A CMC 0,12 % + 43 mA 20 Hz do 1 kHz od 10 do 30 A CMC 0,12 % + 131 mA Střídavý proud / zdroje střídavého proudu Kalibrace – elektrické veličiny Měření s etalonovým multimetrem 20 Hz až 2 kHz 1 µA až 100 µA CMC 0,049 % + 25 nA 20 Hz až 10 kHz 0,1 mA až 1 mA CMC 0,049 % + 0,24 µA 20 Hz až 10 kHz 1 mA až 10 mA CMC 0,049 % + 2,4 µA 20 Hz až 10 kHz 10 mA až 100 mA CMC 0,049 % + 24 µA 20 Hz až 10 kHz 0,1 až 1 A CMC 0,065 % +0,26 mA 20 Hz až 1 kHz 1 až 10 A CMC 0,12 % + 43 mA 20 Hz až 1 kHz 10 až 30 A CMC 0,12 % + 131 mA KL-PM-0301 Prad przemienny / zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar z multimetrem wzorcowym 20 Hz do 2 kHz od 1 µA do 100 µA CMC 0,049 % + 25 nA 20 Hz do 10 kHz od 0,1 mA do 1 mA CMC 0,049 % + 0,24 µA 20 Hz do 10 kHz od 1 mA do 10 mA CMC 0,049 % + 2,4 µA 20 Hz do 10 kHz od 10 mA do 100 mA CMC 0,049 % + 24 µA 20 Hz do 10 kHz od 0,1 do 1 A CMC 0,065 % +0,26 mA 20 Hz do 1 kHz od 1 do 10 A CMC 0,12 % + 43 mA 20 Hz do 1 kHz od 10 do 30 A CMC 0,12 % + 131 mA Stridavy proud / zdroje stridaveho proudu Kalibrace – elektricke veliciny Mereni s etalonovym multimetrem 20 Hz az 2 kHz 1 µA az 100 µA CMC 0,049 % + 25 nA 20 Hz az 10 kHz 0,1 mA az 1 mA CMC 0,049 % + 0,24 µA 20 Hz az 10 kHz 1 mA az 10 mA CMC 0,049 % + 2,4 µA 20 Hz az 10 kHz 10 mA az 100 mA CMC 0,049 % + 24 µA 20 Hz az 10 kHz 0,1 az 1 A CMC 0,065 % +0,26 mA 20 Hz az 1 kHz 1 az 10 A CMC 0,12 % + 43 mA 20 Hz az 1 kHz 10 az 30 A CMC 0,12 % + 131 mA KL-PM-0301","search_en":"AC current / AC current sources Calibration – electrical quantities Measurement by a reference multimeter 20 Hz to 2 kHz 1 µA to 100 µA CMC 0,049 % + 25 nA 20 Hz to 10 kHz 0,1 mA to 1 mA CMC 0,049 % + 0,24 µA 20 Hz to 10 kHz 1 mA to 10 mA CMC 0,049 % + 2,4 µA 20 Hz to 10 kHz 10 mA to 100 mA CMC 0,049 % + 24 µA 20 Hz to 10 kHz 0,1 to 1 A CMC 0,065 % +0,26 mA 20 Hz to 1 kHz 1 to 10 A CMC 0,12 % + 43 mA 20 Hz to 1 kHz 10 to 30 A CMC 0,12 % + 131 mA KL-PM-0301","search_zh":"交流电流 / 交流电流源 校准 – 电学量 用标准万用表测量 20 Hz 至 2 kHz 1 µA 至 100 µA CMC 0,049 % + 25 nA 20 Hz 至 10 kHz 0,1 mA 至 1 mA CMC 0,049 % + 0,24 µA 20 Hz 至 10 kHz 1 mA 至 10 mA CMC 0,049 % + 2,4 µA 20 Hz 至 10 kHz 10 mA 至 100 mA CMC 0,049 % + 24 µA 20 Hz 至 10 kHz 0,1 至 1 A CMC 0,065 % +0,26 mA 20 Hz 至 1 kHz 1 至 10 A CMC 0,12 % + 43 mA 20 Hz 至 1 kHz 10 至 30 A CMC 0,12 % + 131 mA KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"314ae780000960af98031eb4","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"6","test_object":"Rezystancja (prąd stały) / mierniki rezystancji","test_object_en":"DC resistance / DC resistance meters","test_object_zh":"直流电阻 / 直流电阻表","test_object_cs":"Stejnosměrný odpor / měřidla stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 1 Ω","cmc":"0,0025 % + 7,5 µΩ"},{"name":"","range":"od 1 Ω do 10 Ω","cmc":"0,0017 % + 45 µΩ"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"od 0,1 kΩ do 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"0,0017 % + 0,36 Ω"},{"name":"","range":"od 0,1 MΩ do 1 MΩ","cmc":"0,0018 % + 3,9 Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,0025 % + 105 Ω"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,12 %"},{"name":"","range":"od 100 MΩ do 1 GΩ","cmc":"0,24 %"},{"name":"","range":"od 1 GΩ do 10 GΩ","cmc":"0,59 %"},{"name":"","range":"od 10 GΩ do 100 GΩ","cmc":"1,2 %"}],"parameters_en":[{"name":"","range":"0 Ω to 1 Ω","cmc":"0,0025 % + 7,5 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0017 % + 45 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0017 % + 0,36 Ω"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,0018 % + 3,9 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,0025 % + 105 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,12 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,24 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,59 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"1,2 %"}],"parameters_zh":[{"name":"","range":"0 Ω 至 1 Ω","cmc":"0,0025 % + 7,5 µΩ"},{"name":"","range":"1 Ω 至 10 Ω","cmc":"0,0017 % + 45 µΩ"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"0,1 kΩ 至 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"0,0017 % + 0,36 Ω"},{"name":"","range":"0,1 MΩ 至 1 MΩ","cmc":"0,0018 % + 3,9 Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,0025 % + 105 Ω"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,12 %"},{"name":"","range":"100 MΩ 至 1 GΩ","cmc":"0,24 %"},{"name":"","range":"1 GΩ 至 10 GΩ","cmc":"0,59 %"},{"name":"","range":"10 GΩ 至 100 GΩ","cmc":"1,2 %"}],"parameters_cs":[{"name":"","range":"0 Ω až 1 Ω","cmc":"0,0025 % + 7,5 µΩ"},{"name":"","range":"1 Ω až 10 Ω","cmc":"0,0017 % + 45 µΩ"},{"name":"","range":"10 Ω až 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"0,1 kΩ až 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"0,0017 % + 0,36 Ω"},{"name":"","range":"0,1 MΩ až 1 MΩ","cmc":"0,0018 % + 3,9 Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,0025 % + 105 Ω"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,12 %"},{"name":"","range":"100 MΩ až 1 GΩ","cmc":"0,24 %"},{"name":"","range":"1 GΩ až 10 GΩ","cmc":"0,59 %"},{"name":"","range":"10 GΩ až 100 GΩ","cmc":"1,2 %"}],"technique":"Porównanie z multimetrem wzorcowym, symulacja dekadą","technique_en":"Comparison with a reference multimeter, simulation by a resistance box","technique_zh":"与标准万用表比较，用电阻箱模拟","technique_cs":"Porovnání s etalonovým multimetrem, simulace dekádou","techniques":["Porównanie z multimetrem wzorcowym, symulacja dekadą"],"techniques_en":["Comparison with a reference multimeter, simulation by a resistance box"],"techniques_zh":["与标准万用表比较，用电阻箱模拟"],"techniques_cs":["Porovnání s etalonovým multimetrem, simulace dekádou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 1 Ω CMC 0,0025 % + 7,5 µΩ\nod 1 Ω do 10 Ω CMC 0,0017 % + 45 µΩ\nod 10 Ω do 100 Ω CMC 0,0015 % + 0,23 mΩ\nod 0,1 kΩ do 1 kΩ CMC 0,0013 % + 1,8 mΩ\nod 1 kΩ do 10 kΩ CMC 0,0015 % + 18 mΩ\nod 10 kΩ do 100 kΩ CMC 0,0017 % + 0,36 Ω\nod 0,1 MΩ do 1 MΩ CMC 0,0018 % + 3,9 Ω\nod 1 MΩ do 10 MΩ CMC 0,0025 % + 105 Ω\nod 10 MΩ do 100 MΩ CMC 0,12 %\nod 100 MΩ do 1 GΩ CMC 0,24 %\nod 1 GΩ do 10 GΩ CMC 0,59 %\nod 10 GΩ do 100 GΩ CMC 1,2 %\nPorównanie z multimetrem wzorcowym, symulacja dekadą","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja (prąd stały) / mierniki rezystancji Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym, symulacja dekadą od 0 Ω do 1 Ω CMC 0,0025 % + 7,5 µΩ od 1 Ω do 10 Ω CMC 0,0017 % + 45 µΩ od 10 Ω do 100 Ω CMC 0,0015 % + 0,23 mΩ od 0,1 kΩ do 1 kΩ CMC 0,0013 % + 1,8 mΩ od 1 kΩ do 10 kΩ CMC 0,0015 % + 18 mΩ od 10 kΩ do 100 kΩ CMC 0,0017 % + 0,36 Ω od 0,1 MΩ do 1 MΩ CMC 0,0018 % + 3,9 Ω od 1 MΩ do 10 MΩ CMC 0,0025 % + 105 Ω od 10 MΩ do 100 MΩ CMC 0,12 % od 100 MΩ do 1 GΩ CMC 0,24 % od 1 GΩ do 10 GΩ CMC 0,59 % od 10 GΩ do 100 GΩ CMC 1,2 % Stejnosměrný odpor / měřidla stejnosměrného odporu Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem, simulace dekádou 0 Ω až 1 Ω CMC 0,0025 % + 7,5 µΩ 1 Ω až 10 Ω CMC 0,0017 % + 45 µΩ 10 Ω až 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ až 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ až 10 kΩ CMC 0,0015 % + 18 mΩ 10 kΩ až 100 kΩ CMC 0,0017 % + 0,36 Ω 0,1 MΩ až 1 MΩ CMC 0,0018 % + 3,9 Ω 1 MΩ až 10 MΩ CMC 0,0025 % + 105 Ω 10 MΩ až 100 MΩ CMC 0,12 % 100 MΩ až 1 GΩ CMC 0,24 % 1 GΩ až 10 GΩ CMC 0,59 % 10 GΩ až 100 GΩ CMC 1,2 % KL-PM-0301 Rezystancja (prad staly) / mierniki rezystancji Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym, symulacja dekada od 0 Ω do 1 Ω CMC 0,0025 % + 7,5 µΩ od 1 Ω do 10 Ω CMC 0,0017 % + 45 µΩ od 10 Ω do 100 Ω CMC 0,0015 % + 0,23 mΩ od 0,1 kΩ do 1 kΩ CMC 0,0013 % + 1,8 mΩ od 1 kΩ do 10 kΩ CMC 0,0015 % + 18 mΩ od 10 kΩ do 100 kΩ CMC 0,0017 % + 0,36 Ω od 0,1 MΩ do 1 MΩ CMC 0,0018 % + 3,9 Ω od 1 MΩ do 10 MΩ CMC 0,0025 % + 105 Ω od 10 MΩ do 100 MΩ CMC 0,12 % od 100 MΩ do 1 GΩ CMC 0,24 % od 1 GΩ do 10 GΩ CMC 0,59 % od 10 GΩ do 100 GΩ CMC 1,2 % Stejnosmerny odpor / meridla stejnosmerneho odporu Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem, simulace dekadou 0 Ω az 1 Ω CMC 0,0025 % + 7,5 µΩ 1 Ω az 10 Ω CMC 0,0017 % + 45 µΩ 10 Ω az 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ az 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ az 10 kΩ CMC 0,0015 % + 18 mΩ 10 kΩ az 100 kΩ CMC 0,0017 % + 0,36 Ω 0,1 MΩ az 1 MΩ CMC 0,0018 % + 3,9 Ω 1 MΩ az 10 MΩ CMC 0,0025 % + 105 Ω 10 MΩ az 100 MΩ CMC 0,12 % 100 MΩ az 1 GΩ CMC 0,24 % 1 GΩ az 10 GΩ CMC 0,59 % 10 GΩ az 100 GΩ CMC 1,2 % KL-PM-0301","search_en":"DC resistance / DC resistance meters Calibration – electrical quantities Comparison with a reference multimeter, simulation by a resistance box 0 Ω to 1 Ω CMC 0,0025 % + 7,5 µΩ 1 Ω to 10 Ω CMC 0,0017 % + 45 µΩ 10 Ω to 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ to 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ to 10 kΩ CMC 0,0015 % + 18 mΩ 10 kΩ to 100 kΩ CMC 0,0017 % + 0,36 Ω 0,1 MΩ to 1 MΩ CMC 0,0018 % + 3,9 Ω 1 MΩ to 10 MΩ CMC 0,0025 % + 105 Ω 10 MΩ to 100 MΩ CMC 0,12 % 100 MΩ to 1 GΩ CMC 0,24 % 1 GΩ to 10 GΩ CMC 0,59 % 10 GΩ to 100 GΩ CMC 1,2 % KL-PM-0301","search_zh":"直流电阻 / 直流电阻表 校准 – 电学量 与标准万用表比较，用电阻箱模拟 0 Ω 至 1 Ω CMC 0,0025 % + 7,5 µΩ 1 Ω 至 10 Ω CMC 0,0017 % + 45 µΩ 10 Ω 至 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ 至 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ 至 10 kΩ CMC 0,0015 % + 18 mΩ 10 kΩ 至 100 kΩ CMC 0,0017 % + 0,36 Ω 0,1 MΩ 至 1 MΩ CMC 0,0018 % + 3,9 Ω 1 MΩ 至 10 MΩ CMC 0,0025 % + 105 Ω 10 MΩ 至 100 MΩ CMC 0,12 % 100 MΩ 至 1 GΩ CMC 0,24 % 1 GΩ 至 10 GΩ CMC 0,59 % 10 GΩ 至 100 GΩ CMC 1,2 % KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c35b71b7c187ab24cc4c7590","lab_id":"6ade8b3cff06824761708122","country":"CZ","accr_number":"2362","accr_body":"ČIA","row_label":"6","test_object":"Rezystancja (prąd stały) / źródła rezystancji","test_object_en":"DC resistance / DC resistance sources","test_object_zh":"直流电阻 / 直流电阻源","test_object_cs":"Stejnosměrný odpor / zdroje stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 1 Ω","cmc":"0,0025 % + 7,5 µΩ"},{"name":"","range":"od 1 Ω do 10 Ω","cmc":"0,0017 % + 45 µΩ"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"od 0,1 kΩ do 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"0,0017 % + 0,36 Ω"},{"name":"","range":"od 0,1 MΩ do 1 MΩ","cmc":"0,0018 % + 3,9 Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,0025 % + 105 Ω"},{"name":"","range":"od 10 MΩ do 90 MΩ","cmc":"0,025 %"},{"name":"","range":"od 90 MΩ do 900 MΩ","cmc":"0,18 %"},{"name":"","range":"od 900 MΩ do 9 GΩ","cmc":"0,50 %"},{"name":"","range":"od 9 GΩ do 100 GΩ","cmc":"3,8 %"}],"parameters_en":[{"name":"","range":"0 Ω to 1 Ω","cmc":"0,0025 % + 7,5 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0017 % + 45 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0017 % + 0,36 Ω"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,0018 % + 3,9 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,0025 % + 105 Ω"},{"name":"","range":"10 MΩ to 90 MΩ","cmc":"0,025 %"},{"name":"","range":"90 MΩ to 900 MΩ","cmc":"0,18 %"},{"name":"","range":"900 MΩ to 9 GΩ","cmc":"0,50 %"},{"name":"","range":"9 GΩ to 100 GΩ","cmc":"3,8 %"}],"parameters_zh":[{"name":"","range":"0 Ω 至 1 Ω","cmc":"0,0025 % + 7,5 µΩ"},{"name":"","range":"1 Ω 至 10 Ω","cmc":"0,0017 % + 45 µΩ"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"0,1 kΩ 至 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"0,0017 % + 0,36 Ω"},{"name":"","range":"0,1 MΩ 至 1 MΩ","cmc":"0,0018 % + 3,9 Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,0025 % + 105 Ω"},{"name":"","range":"10 MΩ 至 90 MΩ","cmc":"0,025 %"},{"name":"","range":"90 MΩ 至 900 MΩ","cmc":"0,18 %"},{"name":"","range":"900 MΩ 至 9 GΩ","cmc":"0,50 %"},{"name":"","range":"9 GΩ 至 100 GΩ","cmc":"3,8 %"}],"parameters_cs":[{"name":"","range":"0 Ω až 1 Ω","cmc":"0,0025 % + 7,5 µΩ"},{"name":"","range":"1 Ω až 10 Ω","cmc":"0,0017 % + 45 µΩ"},{"name":"","range":"10 Ω až 100 Ω","cmc":"0,0015 % + 0,23 mΩ"},{"name":"","range":"0,1 kΩ až 1 kΩ","cmc":"0,0013 % + 1,8 mΩ"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,0015 % + 18 mΩ"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"0,0017 % + 0,36 Ω"},{"name":"","range":"0,1 MΩ až 1 MΩ","cmc":"0,0018 % + 3,9 Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,0025 % + 105 Ω"},{"name":"","range":"10 MΩ až 90 MΩ","cmc":"0,025 %"},{"name":"","range":"90 MΩ až 900 MΩ","cmc":"0,18 %"},{"name":"","range":"900 MΩ až 9 GΩ","cmc":"0,50 %"},{"name":"","range":"9 GΩ až 100 GΩ","cmc":"3,8 %"}],"technique":"Pomiar multimetrem wzorcowym","technique_en":"Measurement by a reference multimeter","technique_zh":"用标准万用表测量","technique_cs":"Měření etalonovým multimetrem","techniques":["Pomiar multimetrem wzorcowym"],"techniques_en":["Measurement by a reference multimeter"],"techniques_zh":["用标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 1 Ω CMC 0,0025 % + 7,5 µΩ\nod 1 Ω do 10 Ω CMC 0,0017 % + 45 µΩ\nod 10 Ω do 100 Ω CMC 0,0015 % + 0,23 mΩ\nod 0,1 kΩ do 1 kΩ CMC 0,0013 % + 1,8 mΩ\nod 1 kΩ do 10 kΩ CMC 0,0015 % + 18 mΩ\nod 10 kΩ do 100 kΩ CMC 0,0017 % + 0,36 Ω\nod 0,1 MΩ do 1 MΩ CMC 0,0018 % + 3,9 Ω\nod 1 MΩ do 10 MΩ CMC 0,0025 % + 105 Ω\nod 10 MΩ do 90 MΩ CMC 0,025 %\nod 90 MΩ do 900 MΩ CMC 0,18 %\nod 900 MΩ do 9 GΩ CMC 0,50 %\nod 9 GΩ do 100 GΩ CMC 3,8 %\nPomiar multimetrem wzorcowym","reference":"KL-PM-0301","norm_bases":["KL-PM-0301"],"lab_section":"Pracownia Jičín","lab_section_en":"Workplace Jičín","lab_section_zh":"Jičín 工作场所","lab_section_cs":"Pracoviště Jičín","lab_address":"Raisova 547, Holínské Předměstí, 506 01 Jičín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja (prąd stały) / źródła rezystancji Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym od 0 Ω do 1 Ω CMC 0,0025 % + 7,5 µΩ od 1 Ω do 10 Ω CMC 0,0017 % + 45 µΩ od 10 Ω do 100 Ω CMC 0,0015 % + 0,23 mΩ od 0,1 kΩ do 1 kΩ CMC 0,0013 % + 1,8 mΩ od 1 kΩ do 10 kΩ CMC 0,0015 % + 18 mΩ od 10 kΩ do 100 kΩ CMC 0,0017 % + 0,36 Ω od 0,1 MΩ do 1 MΩ CMC 0,0018 % + 3,9 Ω od 1 MΩ do 10 MΩ CMC 0,0025 % + 105 Ω od 10 MΩ do 90 MΩ CMC 0,025 % od 90 MΩ do 900 MΩ CMC 0,18 % od 900 MΩ do 9 GΩ CMC 0,50 % od 9 GΩ do 100 GΩ CMC 3,8 % Stejnosměrný odpor / zdroje stejnosměrného odporu Kalibrace – elektrické veličiny Měření etalonovým multimetrem 0 Ω až 1 Ω CMC 0,0025 % + 7,5 µΩ 1 Ω až 10 Ω CMC 0,0017 % + 45 µΩ 10 Ω až 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ až 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ až 10 kΩ CMC 0,0015 % + 18 mΩ 10 kΩ až 100 kΩ CMC 0,0017 % + 0,36 Ω 0,1 MΩ až 1 MΩ CMC 0,0018 % + 3,9 Ω 1 MΩ až 10 MΩ CMC 0,0025 % + 105 Ω 10 MΩ až 90 MΩ CMC 0,025 % 90 MΩ až 900 MΩ CMC 0,18 % 900 MΩ až 9 GΩ CMC 0,50 % 9 GΩ až 100 GΩ CMC 3,8 % KL-PM-0301 Rezystancja (prad staly) / zrodla rezystancji Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym od 0 Ω do 1 Ω CMC 0,0025 % + 7,5 µΩ od 1 Ω do 10 Ω CMC 0,0017 % + 45 µΩ od 10 Ω do 100 Ω CMC 0,0015 % + 0,23 mΩ od 0,1 kΩ do 1 kΩ CMC 0,0013 % + 1,8 mΩ od 1 kΩ do 10 kΩ CMC 0,0015 % + 18 mΩ od 10 kΩ do 100 kΩ CMC 0,0017 % + 0,36 Ω od 0,1 MΩ do 1 MΩ CMC 0,0018 % + 3,9 Ω od 1 MΩ do 10 MΩ CMC 0,0025 % + 105 Ω od 10 MΩ do 90 MΩ CMC 0,025 % od 90 MΩ do 900 MΩ CMC 0,18 % od 900 MΩ do 9 GΩ CMC 0,50 % od 9 GΩ do 100 GΩ CMC 3,8 % Stejnosmerny odpor / zdroje stejnosmerneho odporu Kalibrace – elektricke veliciny Mereni etalonovym multimetrem 0 Ω az 1 Ω CMC 0,0025 % + 7,5 µΩ 1 Ω az 10 Ω CMC 0,0017 % + 45 µΩ 10 Ω az 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ az 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ az 10 kΩ CMC 0,0015 % + 18 mΩ 10 kΩ az 100 kΩ CMC 0,0017 % + 0,36 Ω 0,1 MΩ az 1 MΩ CMC 0,0018 % + 3,9 Ω 1 MΩ az 10 MΩ CMC 0,0025 % + 105 Ω 10 MΩ az 90 MΩ CMC 0,025 % 90 MΩ az 900 MΩ CMC 0,18 % 900 MΩ az 9 GΩ CMC 0,50 % 9 GΩ az 100 GΩ CMC 3,8 % KL-PM-0301","search_en":"DC resistance / DC resistance sources Calibration – electrical quantities Measurement by a reference multimeter 0 Ω to 1 Ω CMC 0,0025 % + 7,5 µΩ 1 Ω to 10 Ω CMC 0,0017 % + 45 µΩ 10 Ω to 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ to 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ to 10 kΩ CMC 0,0015 % + 18 mΩ 10 kΩ to 100 kΩ CMC 0,0017 % + 0,36 Ω 0,1 MΩ to 1 MΩ CMC 0,0018 % + 3,9 Ω 1 MΩ to 10 MΩ CMC 0,0025 % + 105 Ω 10 MΩ to 90 MΩ CMC 0,025 % 90 MΩ to 900 MΩ CMC 0,18 % 900 MΩ to 9 GΩ CMC 0,50 % 9 GΩ to 100 GΩ CMC 3,8 % KL-PM-0301","search_zh":"直流电阻 / 直流电阻源 校准 – 电学量 用标准万用表测量 0 Ω 至 1 Ω CMC 0,0025 % + 7,5 µΩ 1 Ω 至 10 Ω CMC 0,0017 % + 45 µΩ 10 Ω 至 100 Ω CMC 0,0015 % + 0,23 mΩ 0,1 kΩ 至 1 kΩ CMC 0,0013 % + 1,8 mΩ 1 kΩ 至 10 kΩ CMC 0,0015 % + 18 mΩ 10 kΩ 至 100 kΩ CMC 0,0017 % + 0,36 Ω 0,1 MΩ 至 1 MΩ CMC 0,0018 % + 3,9 Ω 1 MΩ 至 10 MΩ CMC 0,0025 % + 105 Ω 10 MΩ 至 90 MΩ CMC 0,025 % 90 MΩ 至 900 MΩ CMC 0,18 % 900 MΩ 至 9 GΩ CMC 0,50 % 9 GΩ 至 100 GΩ CMC 3,8 % KL-PM-0301","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}