🇨🇿 RHH s.r.o. PL

ČIA 2359 • Pardubice, Czech Republic • 6 calibration items

Metrology & calibration

RHH s.r.o. is a calibration laboratory accredited by ČIA under number 2359 (Pardubice, Czech Republic). Its accreditation scope covers 6 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electronic humidity meters and humidity measuring chains, including…, Electronic thermometers, Electronic thermometers and temperature measuring chains, including…, Gloss meters. Most frequently used calibration principles: Comparison with a standard humidity meter, Comparison with a standard thermometer, Comparison with a standard thermometer in a calibration furnace.

At a glance

  • Accreditation number: ČIA 2359
  • Calibration items in scope: 6
  • Types of calibrated items: 6
  • Calibration principles used: 6
  • City: Pardubice, Czech Republic
  • Valid until: 15-06-2028
Accreditation number
2359
Accreditation body
ČIA
Address
S. K. Neumanna 1316, 530 02 Pardubice
City
Pardubice, Czech Republic
Division
RHH s.r.o. – laboratorium wzorcujące
Valid until
15-06-2028

What this laboratory calibrates (6)

Calibration principles (6)

Certificate information

Certificate date
15.06.2023

Accreditation scope — calibration items (6)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Piston pipettes and piston dispensing systems Calibration – volume
distilled water — 0,5 µl to 10 000 µl · CMC 0,13 % + 0,01µl distilled water — 10 000 µl to 150 000 µl · CMC 0,06 %
CMC for the field of measured quantity: Volume
Gravimetric method RHH-AKP-01 (ČSN EN ISO 8655-6)
2 Electronic thermometers Calibration – temperature
-30 °C to 50 °C · CMC 0,12 °C 50 °C to 140 °C · CMC 0,18 °C 140 °C to 250 °C · CMC 0,32 °C 250 °C to 650 °C · CMC 1,2 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a calibration furnace RHH-AKP-02
3 Electronic thermometers and temperature measuring chains, including thermal and climatic chambers Calibration – temperature
-80 °C to -40 °C · CMC 0,30 °C -40 °C to 50 °C · CMC 0,22 °C 50 °C to 150 °C · CMC 0,30 °C 150 °C to 250 °C · CMC 0,54 °C 250 °C to 500 °C · CMC 1,1 °C 500 °C to 800 °C · CMC 2,1 °C 800 °C to 1000 °C · CMC 2,8 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer RHH-AKP-02
4 Gloss meters Calibration – optical quantities (Gloss)
0 GU to 100 GU · CMC 1,2 GU
CMC for the field of measured quantity: Optical quantities (Gloss)
Direct measurement of gloss standards RHH-AKP-03
5 Gloss standards Calibration – optical quantities (Gloss)
0 GU to 100 GU · CMC 1,4 GU
CMC for the field of measured quantity: Optical quantities (Gloss)
Measurement by a standard gloss meter RHH-AKP-03
6 Electronic humidity meters and humidity measuring chains, including climatic chambers Calibration – humidity
(2 to 20) °C — 10 % RH to 40 % RH · CMC 1,3 % RH (20 to 60) °C — 10 % RH to 40 % RH · CMC 1,1 % RH (60 to 90) °C — 10 % RH to 40 % RH · CMC 1,5 % RH (2 to 20) °C — 40 % RH to 70 % RH · CMC 1,3 % RH (20 to 60) °C — 40 % RH to 70 % RH · CMC 1,2 % RH (60 to 90) °C — 40 % RH to 70 % RH · CMC 1,6 % RH (2 to 20) °C — 70 % RH to 90 % RH · CMC 1,5 % RH (20 to 60) °C — 70 % RH to 90 % RH · CMC 1,3 % RH (60 to 90) °C — 70 % RH to 90 % RH · CMC 1,8 % RH
CMC for the field of measured quantity: Humidity
Comparison with a standard humidity meter RHH-AKP-04

Reference standards (5)

RHH-AKP-01
RHH-AKP-02
RHH-AKP-03
RHH-AKP-04
ČSN EN ISO 8655-6

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2359