{"lab":{"_id":"6acfffeaff06824761705e18","country":"CZ","accr_number":"2359","accr_body":"ČIA","address":"S. K. Neumanna 1316, 530 02 Pardubice","categories":["metrology"],"city":"Pardubice","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[15.7773623,50.0277666]},"map_coord":[50.0277666,15.7773623],"map_geo":"cai-mapa","methods_count":6,"name":"RHH s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: objętość, temperatura, wielkości optyczne (połysk) i wilgotność.","search_text":"rhh s.r.o. s. k. neumanna 1316, 530 02 pardubice 2359","source_page_url":"https://www.cai.cz/?subjekt=2359-rhh-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"15-06-2028","website":"rhh.webnode.cz","certificate_date":"15.06.2023","certificate_no":"316/2023","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: objętość, temperatura, wielkości optyczne (połysk) i wilgotność.","en":"Calibration in the field of volume, temperature, optical quantities (gloss) and humidity.","zh":"体积、温度、光学量（光泽度）和湿度领域的校准。","cs":"Kalibrace v oborech objem, teplota, optické veličiny (lesk) a vlhkost."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"RHH s.r.o. – laboratorium wzorcujące","lab_division_cs":"RHH s.r.o. - kalibrační laboratoř","lab_division_en":"RHH s.r.o. – Calibration Laboratory","lab_division_zh":"RHH s.r.o. 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"fd8f397b703eba794a4d3fdc1422032ee78681f8517aa7dccc93496c85aedac8","source_pdf_url":"https://www.cai.cz/OA/pdf/P316_2023_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P316_2023_EN.pdf"},"methods":[{"_id":"bd344aafa9d66df440ee46c0","lab_id":"6acfffeaff06824761705e18","country":"CZ","accr_number":"2359","accr_body":"ČIA","row_label":"1","test_object":"Pipety tłokowe i tłokowe systemy dozujące","test_object_en":"Piston pipettes and piston dispensing systems","test_object_zh":"活塞移液器和活塞分液系统","test_object_cs":"Pístové pipety a pístové dávkovací systémy","methodology":"Wzorcowanie – objętość","methodology_en":"Calibration – volume","methodology_zh":"校准 – 体积","methodology_cs":"Kalibrace – objem","parameters":[{"name":"woda destylowana","range":"od 0,5 µl do 10 000 µl","cmc":"0,13 % + 0,01µl"},{"name":"woda destylowana","range":"od 10 000 µl do 150 000 µl","cmc":"0,06 %"}],"parameters_en":[{"name":"distilled water","range":"0,5 µl to 10 000 µl","cmc":"0,13 % + 0,01µl"},{"name":"distilled water","range":"10 000 µl to 150 000 µl","cmc":"0,06 %"}],"parameters_zh":[{"name":"蒸馏水","range":"0,5 µl 至 10 000 µl","cmc":"0,13 % + 0,01µl"},{"name":"蒸馏水","range":"10 000 µl 至 150 000 µl","cmc":"0,06 %"}],"parameters_cs":[{"name":"Destilovaná voda","range":"0,5 µl až 10 000 µl","cmc":"0,13 % + 0,01µl"},{"name":"Destilovaná voda","range":"10 000 µl až 150 000 µl","cmc":"0,06 %"}],"technique":"Metoda wagowa","technique_en":"Gravimetric method","technique_zh":"重量法","technique_cs":"Gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["Gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["Gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość\nZakres:\nwoda destylowana od 0,5 µl do 10 000 µl CMC 0,13 % + 0,01µl\nwoda destylowana od 10 000 µl do 150 000 µl CMC 0,06 %\nMetoda wagowa","reference":"RHH-AKP-01 (ČSN EN ISO 8655-6)","norm_bases":["RHH-AKP-01","ČSN EN ISO 8655-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość","regulatory_area_en":"CMC for the field of measured quantity: Volume","regulatory_area_zh":"被测量领域的CMC：体积","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pipety tłokowe i tłokowe systemy dozujące Wzorcowanie – objętość Metoda wagowa woda destylowana od 0,5 µl do 10 000 µl CMC 0,13 % + 0,01µl woda destylowana od 10 000 µl do 150 000 µl CMC 0,06 % Pístové pipety a pístové dávkovací systémy Kalibrace – objem Gravimetricky Destilovaná voda 0,5 µl až 10 000 µl CMC 0,13 % + 0,01µl Destilovaná voda 10 000 µl až 150 000 µl CMC 0,06 % RHH-AKP-01 (ČSN EN ISO 8655-6) Pipety tlokowe i tlokowe systemy dozujace Wzorcowanie – objetosc Metoda wagowa woda destylowana od 0,5 µl do 10 000 µl CMC 0,13 % + 0,01µl woda destylowana od 10 000 µl do 150 000 µl CMC 0,06 % Pistove pipety a pistove davkovaci systemy Kalibrace – objem Gravimetricky Destilovana voda 0,5 µl az 10 000 µl CMC 0,13 % + 0,01µl Destilovana voda 10 000 µl az 150 000 µl CMC 0,06 % RHH-AKP-01 (CSN EN ISO 8655-6)","search_en":"Piston pipettes and piston dispensing systems Calibration – volume Gravimetric method distilled water 0,5 µl to 10 000 µl CMC 0,13 % + 0,01µl distilled water 10 000 µl to 150 000 µl CMC 0,06 % RHH-AKP-01 (ČSN EN ISO 8655-6)","search_zh":"活塞移液器和活塞分液系统 校准 – 体积 重量法 蒸馏水 0,5 µl 至 10 000 µl CMC 0,13 % + 0,01µl 蒸馏水 10 000 µl 至 150 000 µl CMC 0,06 % RHH-AKP-01 (ČSN EN ISO 8655-6)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ada8924fdaa8d4537c453845","lab_id":"6acfffeaff06824761705e18","country":"CZ","accr_number":"2359","accr_body":"ČIA","row_label":"1","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 50 °C","cmc":"0,12 °C"},{"name":"","range":"od 50 °C do 140 °C","cmc":"0,18 °C"},{"name":"","range":"od 140 °C do 250 °C","cmc":"0,32 °C"},{"name":"","range":"od 250 °C do 650 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 50 °C","cmc":"0,12 °C"},{"name":"","range":"50 °C to 140 °C","cmc":"0,18 °C"},{"name":"","range":"140 °C to 250 °C","cmc":"0,32 °C"},{"name":"","range":"250 °C to 650 °C","cmc":"1,2 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 50 °C","cmc":"0,12 °C"},{"name":"","range":"50 °C 至 140 °C","cmc":"0,18 °C"},{"name":"","range":"140 °C 至 250 °C","cmc":"0,32 °C"},{"name":"","range":"250 °C 至 650 °C","cmc":"1,2 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 50 °C","cmc":"0,12 °C"},{"name":"","range":"50 °C až 140 °C","cmc":"0,18 °C"},{"name":"","range":"140 °C až 250 °C","cmc":"0,32 °C"},{"name":"","range":"250 °C až 650 °C","cmc":"1,2 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecu wzorcującym","technique_en":"Comparison with a standard thermometer in a calibration furnace","technique_zh":"在校准炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kalibrační pícce","techniques":["Porównanie z termometrem wzorcowym w piecu wzorcującym"],"techniques_en":["Comparison with a standard thermometer in a calibration furnace"],"techniques_zh":["在校准炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 50 °C CMC 0,12 °C\nod 50 °C do 140 °C CMC 0,18 °C\nod 140 °C do 250 °C CMC 0,32 °C\nod 250 °C do 650 °C CMC 1,2 °C\nPorównanie z termometrem wzorcowym w piecu wzorcującym","reference":"RHH-AKP-02","norm_bases":["RHH-AKP-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecu wzorcującym od -30 °C do 50 °C CMC 0,12 °C od 50 °C do 140 °C CMC 0,18 °C od 140 °C do 250 °C CMC 0,32 °C od 250 °C do 650 °C CMC 1,2 °C Elektronické teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem v kalibrační pícce -30 °C až 50 °C CMC 0,12 °C 50 °C až 140 °C CMC 0,18 °C 140 °C až 250 °C CMC 0,32 °C 250 °C až 650 °C CMC 1,2 °C RHH-AKP-02 Termometry elektroniczne Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecu wzorcujacym od -30 °C do 50 °C CMC 0,12 °C od 50 °C do 140 °C CMC 0,18 °C od 140 °C do 250 °C CMC 0,32 °C od 250 °C do 650 °C CMC 1,2 °C Elektronicke teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem v kalibracni picce -30 °C az 50 °C CMC 0,12 °C 50 °C az 140 °C CMC 0,18 °C 140 °C az 250 °C CMC 0,32 °C 250 °C az 650 °C CMC 1,2 °C RHH-AKP-02","search_en":"Electronic thermometers Calibration – temperature Comparison with a standard thermometer in a calibration furnace -30 °C to 50 °C CMC 0,12 °C 50 °C to 140 °C CMC 0,18 °C 140 °C to 250 °C CMC 0,32 °C 250 °C to 650 °C CMC 1,2 °C RHH-AKP-02","search_zh":"电子温度计 校准 – 温度 在校准炉中与标准温度计比较 -30 °C 至 50 °C CMC 0,12 °C 50 °C 至 140 °C CMC 0,18 °C 140 °C 至 250 °C CMC 0,32 °C 250 °C 至 650 °C CMC 1,2 °C RHH-AKP-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7edc175370a5f7fc5097a3d7","lab_id":"6acfffeaff06824761705e18","country":"CZ","accr_number":"2359","accr_body":"ČIA","row_label":"2","test_object":"Termometry elektroniczne i tory pomiarowe temperatury, w tym komory termiczne i klimatyczne","test_object_en":"Electronic thermometers and temperature measuring chains, including thermal and climatic chambers","test_object_zh":"电子温度计和温度测量链，包括热箱和气候箱","test_object_cs":"Elektronické teploměry a měřící řetězce teploty včetně teplotních a klimatických komor","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do -40 °C","cmc":"0,30 °C"},{"name":"","range":"od -40 °C do 50 °C","cmc":"0,22 °C"},{"name":"","range":"od 50 °C do 150 °C","cmc":"0,30 °C"},{"name":"","range":"od 150 °C do 250 °C","cmc":"0,54 °C"},{"name":"","range":"od 250 °C do 500 °C","cmc":"1,1 °C"},{"name":"","range":"od 500 °C do 800 °C","cmc":"2,1 °C"},{"name":"","range":"od 800 °C do 1000 °C","cmc":"2,8 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -40 °C","cmc":"0,30 °C"},{"name":"","range":"-40 °C to 50 °C","cmc":"0,22 °C"},{"name":"","range":"50 °C to 150 °C","cmc":"0,30 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,54 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"1,1 °C"},{"name":"","range":"500 °C to 800 °C","cmc":"2,1 °C"},{"name":"","range":"800 °C to 1000 °C","cmc":"2,8 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 -40 °C","cmc":"0,30 °C"},{"name":"","range":"-40 °C 至 50 °C","cmc":"0,22 °C"},{"name":"","range":"50 °C 至 150 °C","cmc":"0,30 °C"},{"name":"","range":"150 °C 至 250 °C","cmc":"0,54 °C"},{"name":"","range":"250 °C 至 500 °C","cmc":"1,1 °C"},{"name":"","range":"500 °C 至 800 °C","cmc":"2,1 °C"},{"name":"","range":"800 °C 至 1000 °C","cmc":"2,8 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až -40 °C","cmc":"0,30 °C"},{"name":"","range":"-40 °C až 50 °C","cmc":"0,22 °C"},{"name":"","range":"50 °C až 150 °C","cmc":"0,30 °C"},{"name":"","range":"150 °C až 250 °C","cmc":"0,54 °C"},{"name":"","range":"250 °C až 500 °C","cmc":"1,1 °C"},{"name":"","range":"500 °C až 800 °C","cmc":"2,1 °C"},{"name":"","range":"800 °C až 1000 °C","cmc":"2,8 °C"}],"technique":"Porównanie z termometrem wzorcowym","technique_en":"Comparison with a standard thermometer","technique_zh":"与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem","techniques":["Porównanie z termometrem wzorcowym"],"techniques_en":["Comparison with a standard thermometer"],"techniques_zh":["与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do -40 °C CMC 0,30 °C\nod -40 °C do 50 °C CMC 0,22 °C\nod 50 °C do 150 °C CMC 0,30 °C\nod 150 °C do 250 °C CMC 0,54 °C\nod 250 °C do 500 °C CMC 1,1 °C\nod 500 °C do 800 °C CMC 2,1 °C\nod 800 °C do 1000 °C CMC 2,8 °C\nPorównanie z termometrem wzorcowym","reference":"RHH-AKP-02","norm_bases":["RHH-AKP-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne i tory pomiarowe temperatury, w tym komory termiczne i klimatyczne Wzorcowanie – temperatura Porównanie z termometrem wzorcowym od -80 °C do -40 °C CMC 0,30 °C od -40 °C do 50 °C CMC 0,22 °C od 50 °C do 150 °C CMC 0,30 °C od 150 °C do 250 °C CMC 0,54 °C od 250 °C do 500 °C CMC 1,1 °C od 500 °C do 800 °C CMC 2,1 °C od 800 °C do 1000 °C CMC 2,8 °C Elektronické teploměry a měřící řetězce teploty včetně teplotních a klimatických komor Kalibrace – teplota Porovnání s etalonovým teploměrem -80 °C až -40 °C CMC 0,30 °C -40 °C až 50 °C CMC 0,22 °C 50 °C až 150 °C CMC 0,30 °C 150 °C až 250 °C CMC 0,54 °C 250 °C až 500 °C CMC 1,1 °C 500 °C až 800 °C CMC 2,1 °C 800 °C až 1000 °C CMC 2,8 °C RHH-AKP-02 Termometry elektroniczne i tory pomiarowe temperatury, w tym komory termiczne i klimatyczne Wzorcowanie – temperatura Porownanie z termometrem wzorcowym od -80 °C do -40 °C CMC 0,30 °C od -40 °C do 50 °C CMC 0,22 °C od 50 °C do 150 °C CMC 0,30 °C od 150 °C do 250 °C CMC 0,54 °C od 250 °C do 500 °C CMC 1,1 °C od 500 °C do 800 °C CMC 2,1 °C od 800 °C do 1000 °C CMC 2,8 °C Elektronicke teplomery a merici retezce teploty vcetne teplotnich a klimatickych komor Kalibrace – teplota Porovnani s etalonovym teplomerem -80 °C az -40 °C CMC 0,30 °C -40 °C az 50 °C CMC 0,22 °C 50 °C az 150 °C CMC 0,30 °C 150 °C az 250 °C CMC 0,54 °C 250 °C az 500 °C CMC 1,1 °C 500 °C az 800 °C CMC 2,1 °C 800 °C az 1000 °C CMC 2,8 °C RHH-AKP-02","search_en":"Electronic thermometers and temperature measuring chains, including thermal and climatic chambers Calibration – temperature Comparison with a standard thermometer -80 °C to -40 °C CMC 0,30 °C -40 °C to 50 °C CMC 0,22 °C 50 °C to 150 °C CMC 0,30 °C 150 °C to 250 °C CMC 0,54 °C 250 °C to 500 °C CMC 1,1 °C 500 °C to 800 °C CMC 2,1 °C 800 °C to 1000 °C CMC 2,8 °C RHH-AKP-02","search_zh":"电子温度计和温度测量链，包括热箱和气候箱 校准 – 温度 与标准温度计比较 -80 °C 至 -40 °C CMC 0,30 °C -40 °C 至 50 °C CMC 0,22 °C 50 °C 至 150 °C CMC 0,30 °C 150 °C 至 250 °C CMC 0,54 °C 250 °C 至 500 °C CMC 1,1 °C 500 °C 至 800 °C CMC 2,1 °C 800 °C 至 1000 °C CMC 2,8 °C RHH-AKP-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"850b430ce98e27e9d61f1eef","lab_id":"6acfffeaff06824761705e18","country":"CZ","accr_number":"2359","accr_body":"ČIA","row_label":"1","test_object":"Połyskomierze","test_object_en":"Gloss meters","test_object_zh":"光泽度计","test_object_cs":"Leskoměry","methodology":"Wzorcowanie – wielkości optyczne (połysk)","methodology_en":"Calibration – optical quantities (Gloss)","methodology_zh":"校准 – 光学量（光泽度）","methodology_cs":"Kalibrace – optické veličiny (Lesk)","parameters":[{"name":"","range":"od 0 GU do 100 GU","cmc":"1,2 GU"}],"parameters_en":[{"name":"","range":"0 GU to 100 GU","cmc":"1,2 GU"}],"parameters_zh":[{"name":"","range":"0 GU 至 100 GU","cmc":"1,2 GU"}],"parameters_cs":[{"name":"","range":"0 GU až 100 GU","cmc":"1,2 GU"}],"technique":"Bezpośredni pomiar wzorców połysku","technique_en":"Direct measurement of gloss standards","technique_zh":"直接测量光泽度标准器","technique_cs":"Přímé měření etalonů lesku","techniques":["Bezpośredni pomiar wzorców połysku"],"techniques_en":["Direct measurement of gloss standards"],"techniques_zh":["直接测量光泽度标准器"],"techniques_cs":["Přímé měření etalonů lesku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne (połysk)\nod 0 GU do 100 GU CMC 1,2 GU\nBezpośredni pomiar wzorców połysku","reference":"RHH-AKP-03","norm_bases":["RHH-AKP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne (połysk)","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities (Gloss)","regulatory_area_zh":"被测量领域的CMC：光学量（光泽度）","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny (Lesk)","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Połyskomierze Wzorcowanie – wielkości optyczne (połysk) Bezpośredni pomiar wzorców połysku od 0 GU do 100 GU CMC 1,2 GU Leskoměry Kalibrace – optické veličiny (Lesk) Přímé měření etalonů lesku 0 GU až 100 GU CMC 1,2 GU RHH-AKP-03 Polyskomierze Wzorcowanie – wielkosci optyczne (polysk) Bezposredni pomiar wzorcow polysku od 0 GU do 100 GU CMC 1,2 GU Leskomery Kalibrace – opticke veliciny (Lesk) Prime mereni etalonu lesku 0 GU az 100 GU CMC 1,2 GU RHH-AKP-03","search_en":"Gloss meters Calibration – optical quantities (Gloss) Direct measurement of gloss standards 0 GU to 100 GU CMC 1,2 GU RHH-AKP-03","search_zh":"光泽度计 校准 – 光学量（光泽度） 直接测量光泽度标准器 0 GU 至 100 GU CMC 1,2 GU RHH-AKP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"113712c20cc3b17753d1aa86","lab_id":"6acfffeaff06824761705e18","country":"CZ","accr_number":"2359","accr_body":"ČIA","row_label":"2","test_object":"Wzorce połysku","test_object_en":"Gloss standards","test_object_zh":"光泽度标准器","test_object_cs":"Etalony lesku","methodology":"Wzorcowanie – wielkości optyczne (połysk)","methodology_en":"Calibration – optical quantities (Gloss)","methodology_zh":"校准 – 光学量（光泽度）","methodology_cs":"Kalibrace – optické veličiny (Lesk)","parameters":[{"name":"","range":"od 0 GU do 100 GU","cmc":"1,4 GU"}],"parameters_en":[{"name":"","range":"0 GU to 100 GU","cmc":"1,4 GU"}],"parameters_zh":[{"name":"","range":"0 GU 至 100 GU","cmc":"1,4 GU"}],"parameters_cs":[{"name":"","range":"0 GU až 100 GU","cmc":"1,4 GU"}],"technique":"Pomiar połyskomierzem wzorcowym","technique_en":"Measurement by a standard gloss meter","technique_zh":"用标准光泽度计测量","technique_cs":"Měření etalonovým leskoměrem","techniques":["Pomiar połyskomierzem wzorcowym"],"techniques_en":["Measurement by a standard gloss meter"],"techniques_zh":["用标准光泽度计测量"],"techniques_cs":["Měření etalonovým leskoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne (połysk)\nod 0 GU do 100 GU CMC 1,4 GU\nPomiar połyskomierzem wzorcowym","reference":"RHH-AKP-03","norm_bases":["RHH-AKP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne (połysk)","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities (Gloss)","regulatory_area_zh":"被测量领域的CMC：光学量（光泽度）","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny (Lesk)","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorce połysku Wzorcowanie – wielkości optyczne (połysk) Pomiar połyskomierzem wzorcowym od 0 GU do 100 GU CMC 1,4 GU Etalony lesku Kalibrace – optické veličiny (Lesk) Měření etalonovým leskoměrem 0 GU až 100 GU CMC 1,4 GU RHH-AKP-03 Wzorce polysku Wzorcowanie – wielkosci optyczne (polysk) Pomiar polyskomierzem wzorcowym od 0 GU do 100 GU CMC 1,4 GU Etalony lesku Kalibrace – opticke veliciny (Lesk) Mereni etalonovym leskomerem 0 GU az 100 GU CMC 1,4 GU RHH-AKP-03","search_en":"Gloss standards Calibration – optical quantities (Gloss) Measurement by a standard gloss meter 0 GU to 100 GU CMC 1,4 GU RHH-AKP-03","search_zh":"光泽度标准器 校准 – 光学量（光泽度） 用标准光泽度计测量 0 GU 至 100 GU CMC 1,4 GU RHH-AKP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd4691386ba74632af5d4339","lab_id":"6acfffeaff06824761705e18","country":"CZ","accr_number":"2359","accr_body":"ČIA","row_label":"1","test_object":"Wilgotnościomierze elektroniczne i tory pomiarowe wilgotności, w tym komory klimatyczne","test_object_en":"Electronic humidity meters and humidity measuring chains, including climatic chambers","test_object_zh":"电子湿度计和湿度测量链，包括气候箱","test_object_cs":"Elektronické vlhkoměry a měřící řetězce vlhkosti včetně klimatických komor","methodology":"Wzorcowanie – wilgotność","methodology_en":"Calibration – humidity","methodology_zh":"校准 – 湿度","methodology_cs":"Kalibrace – vlhkost","parameters":[{"name":"(2 do 20) °C","range":"od 10 % RH do 40 % RH","cmc":"1,3 % RH"},{"name":"(20 do 60) °C","range":"od 10 % RH do 40 % RH","cmc":"1,1 % RH"},{"name":"(60 do 90) °C","range":"od 10 % RH do 40 % RH","cmc":"1,5 % RH"},{"name":"(2 do 20) °C","range":"od 40 % RH do 70 % RH","cmc":"1,3 % RH"},{"name":"(20 do 60) °C","range":"od 40 % RH do 70 % RH","cmc":"1,2 % RH"},{"name":"(60 do 90) °C","range":"od 40 % RH do 70 % RH","cmc":"1,6 % RH"},{"name":"(2 do 20) °C","range":"od 70 % RH do 90 % RH","cmc":"1,5 % RH"},{"name":"(20 do 60) °C","range":"od 70 % RH do 90 % RH","cmc":"1,3 % RH"},{"name":"(60 do 90) °C","range":"od 70 % RH do 90 % RH","cmc":"1,8 % RH"}],"parameters_en":[{"name":"(2 to 20) °C","range":"10 % RH to 40 % RH","cmc":"1,3 % RH"},{"name":"(20 to 60) °C","range":"10 % RH to 40 % RH","cmc":"1,1 % RH"},{"name":"(60 to 90) °C","range":"10 % RH to 40 % RH","cmc":"1,5 % RH"},{"name":"(2 to 20) °C","range":"40 % RH to 70 % RH","cmc":"1,3 % RH"},{"name":"(20 to 60) °C","range":"40 % RH to 70 % RH","cmc":"1,2 % RH"},{"name":"(60 to 90) °C","range":"40 % RH to 70 % RH","cmc":"1,6 % RH"},{"name":"(2 to 20) °C","range":"70 % RH to 90 % RH","cmc":"1,5 % RH"},{"name":"(20 to 60) °C","range":"70 % RH to 90 % RH","cmc":"1,3 % RH"},{"name":"(60 to 90) °C","range":"70 % RH to 90 % RH","cmc":"1,8 % RH"}],"parameters_zh":[{"name":"(2 至 20) °C","range":"10 % RH 至 40 % RH","cmc":"1,3 % RH"},{"name":"(20 至 60) °C","range":"10 % RH 至 40 % RH","cmc":"1,1 % RH"},{"name":"(60 至 90) °C","range":"10 % RH 至 40 % RH","cmc":"1,5 % RH"},{"name":"(2 至 20) °C","range":"40 % RH 至 70 % RH","cmc":"1,3 % RH"},{"name":"(20 至 60) °C","range":"40 % RH 至 70 % RH","cmc":"1,2 % RH"},{"name":"(60 至 90) °C","range":"40 % RH 至 70 % RH","cmc":"1,6 % RH"},{"name":"(2 至 20) °C","range":"70 % RH 至 90 % RH","cmc":"1,5 % RH"},{"name":"(20 至 60) °C","range":"70 % RH 至 90 % RH","cmc":"1,3 % RH"},{"name":"(60 至 90) °C","range":"70 % RH 至 90 % RH","cmc":"1,8 % RH"}],"parameters_cs":[{"name":"(2 až 20) °C","range":"10 % RH až 40 % RH","cmc":"1,3 % RH"},{"name":"(20 až 60) °C","range":"10 % RH až 40 % RH","cmc":"1,1 % RH"},{"name":"(60 až 90) °C","range":"10 % RH až 40 % RH","cmc":"1,5 % RH"},{"name":"(2 až 20) °C","range":"40 % RH až 70 % RH","cmc":"1,3 % RH"},{"name":"(20 až 60) °C","range":"40 % RH až 70 % RH","cmc":"1,2 % RH"},{"name":"(60 až 90) °C","range":"40 % RH až 70 % RH","cmc":"1,6 % RH"},{"name":"(2 až 20) °C","range":"70 % RH až 90 % RH","cmc":"1,5 % RH"},{"name":"(20 až 60) °C","range":"70 % RH až 90 % RH","cmc":"1,3 % RH"},{"name":"(60 až 90) °C","range":"70 % RH až 90 % RH","cmc":"1,8 % RH"}],"technique":"Porównanie z wilgotnościomierzem wzorcowym","technique_en":"Comparison with a standard humidity meter","technique_zh":"与标准湿度计比较","technique_cs":"Porovnání s etalonovým vlhkoměrem","techniques":["Porównanie z wilgotnościomierzem wzorcowym"],"techniques_en":["Comparison with a standard humidity meter"],"techniques_zh":["与标准湿度计比较"],"techniques_cs":["Porovnání s etalonovým vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność\nZakres:\n(2 do 20) °C od 10 % RH do 40 % RH CMC 1,3 % RH\n(20 do 60) °C od 10 % RH do 40 % RH CMC 1,1 % RH\n(60 do 90) °C od 10 % RH do 40 % RH CMC 1,5 % RH\n(2 do 20) °C od 40 % RH do 70 % RH CMC 1,3 % RH\n(20 do 60) °C od 40 % RH do 70 % RH CMC 1,2 % RH\n(60 do 90) °C od 40 % RH do 70 % RH CMC 1,6 % RH\n(2 do 20) °C od 70 % RH do 90 % RH CMC 1,5 % RH\n(20 do 60) °C od 70 % RH do 90 % RH CMC 1,3 % RH\n(60 do 90) °C od 70 % RH do 90 % RH CMC 1,8 % RH\nPorównanie z wilgotnościomierzem wzorcowym","reference":"RHH-AKP-04","norm_bases":["RHH-AKP-04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność","regulatory_area_en":"CMC for the field of measured quantity: Humidity","regulatory_area_zh":"被测量领域的CMC：湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotnościomierze elektroniczne i tory pomiarowe wilgotności, w tym komory klimatyczne Wzorcowanie – wilgotność Porównanie z wilgotnościomierzem wzorcowym (2 do 20) °C od 10 % RH do 40 % RH CMC 1,3 % RH (20 do 60) °C od 10 % RH do 40 % RH CMC 1,1 % RH (60 do 90) °C od 10 % RH do 40 % RH CMC 1,5 % RH (2 do 20) °C od 40 % RH do 70 % RH CMC 1,3 % RH (20 do 60) °C od 40 % RH do 70 % RH CMC 1,2 % RH (60 do 90) °C od 40 % RH do 70 % RH CMC 1,6 % RH (2 do 20) °C od 70 % RH do 90 % RH CMC 1,5 % RH (20 do 60) °C od 70 % RH do 90 % RH CMC 1,3 % RH (60 do 90) °C od 70 % RH do 90 % RH CMC 1,8 % RH Elektronické vlhkoměry a měřící řetězce vlhkosti včetně klimatických komor Kalibrace – vlhkost Porovnání s etalonovým vlhkoměrem (2 až 20) °C 10 % RH až 40 % RH CMC 1,3 % RH (20 až 60) °C 10 % RH až 40 % RH CMC 1,1 % RH (60 až 90) °C 10 % RH až 40 % RH CMC 1,5 % RH (2 až 20) °C 40 % RH až 70 % RH CMC 1,3 % RH (20 až 60) °C 40 % RH až 70 % RH CMC 1,2 % RH (60 až 90) °C 40 % RH až 70 % RH CMC 1,6 % RH (2 až 20) °C 70 % RH až 90 % RH CMC 1,5 % RH (20 až 60) °C 70 % RH až 90 % RH CMC 1,3 % RH (60 až 90) °C 70 % RH až 90 % RH CMC 1,8 % RH RHH-AKP-04 Wilgotnosciomierze elektroniczne i tory pomiarowe wilgotnosci, w tym komory klimatyczne Wzorcowanie – wilgotnosc Porownanie z wilgotnosciomierzem wzorcowym (2 do 20) °C od 10 % RH do 40 % RH CMC 1,3 % RH (20 do 60) °C od 10 % RH do 40 % RH CMC 1,1 % RH (60 do 90) °C od 10 % RH do 40 % RH CMC 1,5 % RH (2 do 20) °C od 40 % RH do 70 % RH CMC 1,3 % RH (20 do 60) °C od 40 % RH do 70 % RH CMC 1,2 % RH (60 do 90) °C od 40 % RH do 70 % RH CMC 1,6 % RH (2 do 20) °C od 70 % RH do 90 % RH CMC 1,5 % RH (20 do 60) °C od 70 % RH do 90 % RH CMC 1,3 % RH (60 do 90) °C od 70 % RH do 90 % RH CMC 1,8 % RH Elektronicke vlhkomery a merici retezce vlhkosti vcetne klimatickych komor Kalibrace – vlhkost Porovnani s etalonovym vlhkomerem (2 az 20) °C 10 % RH az 40 % RH CMC 1,3 % RH (20 az 60) °C 10 % RH az 40 % RH CMC 1,1 % RH (60 az 90) °C 10 % RH az 40 % RH CMC 1,5 % RH (2 az 20) °C 40 % RH az 70 % RH CMC 1,3 % RH (20 az 60) °C 40 % RH az 70 % RH CMC 1,2 % RH (60 az 90) °C 40 % RH az 70 % RH CMC 1,6 % RH (2 az 20) °C 70 % RH az 90 % RH CMC 1,5 % RH (20 az 60) °C 70 % RH az 90 % RH CMC 1,3 % RH (60 az 90) °C 70 % RH az 90 % RH CMC 1,8 % RH RHH-AKP-04","search_en":"Electronic humidity meters and humidity measuring chains, including climatic chambers Calibration – humidity Comparison with a standard humidity meter (2 to 20) °C 10 % RH to 40 % RH CMC 1,3 % RH (20 to 60) °C 10 % RH to 40 % RH CMC 1,1 % RH (60 to 90) °C 10 % RH to 40 % RH CMC 1,5 % RH (2 to 20) °C 40 % RH to 70 % RH CMC 1,3 % RH (20 to 60) °C 40 % RH to 70 % RH CMC 1,2 % RH (60 to 90) °C 40 % RH to 70 % RH CMC 1,6 % RH (2 to 20) °C 70 % RH to 90 % RH CMC 1,5 % RH (20 to 60) °C 70 % RH to 90 % RH CMC 1,3 % RH (60 to 90) °C 70 % RH to 90 % RH CMC 1,8 % RH RHH-AKP-04","search_zh":"电子湿度计和湿度测量链，包括气候箱 校准 – 湿度 与标准湿度计比较 (2 至 20) °C 10 % RH 至 40 % RH CMC 1,3 % RH (20 至 60) °C 10 % RH 至 40 % RH CMC 1,1 % RH (60 至 90) °C 10 % RH 至 40 % RH CMC 1,5 % RH (2 至 20) °C 40 % RH 至 70 % RH CMC 1,3 % RH (20 至 60) °C 40 % RH 至 70 % RH CMC 1,2 % RH (60 至 90) °C 40 % RH 至 70 % RH CMC 1,6 % RH (2 至 20) °C 70 % RH 至 90 % RH CMC 1,5 % RH (20 至 60) °C 70 % RH 至 90 % RH CMC 1,3 % RH (60 至 90) °C 70 % RH 至 90 % RH CMC 1,8 % RH RHH-AKP-04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}