Testo, s.r.o. is a calibration laboratory accredited by ČIA under number 2344 (Praha 5, Czech Republic). Its accreditation scope covers 7 calibration items in the following areas: Metrology & calibration. Calibrated items include: Digital pressure gauges, Contact digital thermometers, Contactless digital thermometers and thermal cameras in pyrometer mode, Digital anemometers. Most frequently used calibration principles: Comparison with a standard digital pressure gauge, -90 °C to -30 °C and 250 °C to 600 °C: comparison with a standard d…, Comparison with a standard dew point hygrometer in a humidity gener….

At a glance

  • Accreditation number: ČIA 2344
  • Calibration items in scope: 7
  • Types of calibrated items: 6
  • Calibration principles used: 6
  • City: Praha 5, Czech Republic
  • Valid until: 09-06-2031
Accreditation number
2344
Accreditation body
ČIA
Address
Jinonická 804/80, Košíře, 158 00 Praha 5
City
Praha 5, Czech Republic
Division
Laboratorium wzorcujące Testo
Valid until
09-06-2031

What this laboratory calibrates (6)

Calibration principles (6)

Certificate information

Certificate date
09.06.2026

Accreditation scope — calibration items (7)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Digital anemometers Calibration – airflow
0,1 m/s to 1,0 m/s · CMC 0,09 m/s 1,0 m/s to 5,0 m/s · CMC 0,18 m/s 5,0 m/s to 20 m/s · CMC 0,20 m/s 20 m/s to 35 m/s · CMC 0,35 m/s
CMC for the field of measured quantity: Airflow
Comparison with a standard in a wind tunnel KP-05
2 Digital pressure gauges Calibration – pressure
vacuum, gauge pressure, gas — -400 hPa to 400 hPa · CMC 1,2 hPa
CMC for the field of measured quantity: Pressure
Comparison with a standard digital pressure gauge KP-06
3 Digital pressure gauges Calibration – pressure
gauge pressure, gas — 0 bar to 10 bar · CMC 0,02 bar gauge pressure, gas — 10 bar to 50 bar · CMC 0,03 bar gauge pressure, gas — 50 bar to 60 bar · CMC 0,04 bar
CMC for the field of measured quantity: Pressure
Comparison with a standard digital pressure gauge KP-06
4 Digital thermometers Calibration – temperature
-90 °C to -80 °C · CMC 0,50 °C -80 °C to -40 °C · CMC 0,30 °C -40 °C to -30 °C · CMC 0,15 °C -30 °C to 120 °C · CMC 0,06 °C 120 °C to 250 °C · CMC 0,13 °C 250 °C to 300 °C · CMC 0,15 °C 300 °C to 400 °C · CMC 0,30 °C 400 °C to 450 °C · CMC 0,50 °C 450 °C to 600 °C · CMC 0,65 °C
CMC for the field of measured quantity: Temperature
-90 °C to -30 °C and 250 °C to 600 °C: comparison with a standard digital thermometer in a dry block; -30 °C to 250 °C: comparison with a standard digital thermometer in a thermostatic bath KP-01
5 Contact digital thermometers Calibration – temperature
-20 °C to 25 °C · CMC 1,5 °C 25 °C to 100 °C · CMC 1,0 °C 100 °C to 150 °C · CMC 1,5 °C 150 °C to 200 °C · CMC 2,0 °C 200 °C to 250 °C · CMC 2,5 °C 250 °C to 300 °C · CMC 3,0 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard digital thermometer on an aluminium contact plate KP-02
6 Contactless digital thermometers and thermal cameras in pyrometer mode Calibration – temperature
-30 °C to -10 °C · CMC 2,7 °C -10 °C to 0 °C · CMC 2,0 °C 0 °C to 35 °C · CMC 1,5 °C 35 °C to 90 °C · CMC 1,8 °C 90 °C to 120 °C · CMC 2,2 °C 120 °C to 150 °C · CMC 2,5 °C 150 °C to 200 °C · CMC 3,0 °C 200 °C to 400 °C · CMC 4,5 °C 400 °C to 500 °C · CMC 5,5 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard gray body KP-03
7 Relative air humidity / digital hygrometers Calibration – air humidity
(20 to 30) °C — 5 % RH to 35 % RH · CMC 0,6 % RH (20 to 30) °C — 35 % RH to 75 % RH · CMC 0,8 % RH (20 to 30) °C — 75 % RH to 90 % RH · CMC 1,0 % RH (20 to 30) °C — 90 % RH to 95 % RH · CMC 1,5 % RH
CMC for the field of measured quantity: Air humidity
Comparison with a standard dew point hygrometer in a humidity generator KP-04