{"lab":{"_id":"6acfffe9ff06824761705e16","accr_number":"2344","country":"CZ","accr_body":"ČIA","address":"Jinonická 804/80, Košíře, 158 00 Praha 5","categories":["metrology"],"city":"Praha 5","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.3747469,50.0615531]},"map_coord":[50.0615531,14.3747469],"map_geo":"cai-mapa","methods_count":7,"name":"Testo, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: temperatura, ciśnienie, wilgotność powietrza i przepływ powietrza, w zakresie określonym w załączniku do świadectwa.","search_text":"testo, s.r.o. jinonická 804/80, košíře, 158 00 praha 5 2344","source_page_url":"https://www.cai.cz/?subjekt=2344-testo-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"09-06-2031","website":"www.testo.com/cz-CZ/","certificate_date":"09.06.2026","certificate_no":"286/2026","certificate_replaces":"682/2023 z 19.12.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: temperatura, ciśnienie, wilgotność powietrza i przepływ powietrza, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of temperature, pressure, air humidity and airflow to the extent as specified in the appendix to this Certificate.","zh":"温度、压力、空气湿度和气流领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech teplota, tlak, vlhkost vzduchu a proudění vzduchu, vymezené přílohou tohoto osvědčení.","de":"Kalibrierung in den Bereichen: Temperatur, Druck, Luftfeuchte und Luftdurchfluss, im Umfang gemäß Anlage zur Akkreditierungsurkunde."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące Testo","lab_division_cs":"Kalibrační laboratoř Testo","lab_division_en":"Testo calibration laboratory","lab_division_zh":"Testo 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"7230c1a0f64df633d244d018cbe83c7f7690b259a4a0e046ac71e3ba53c1b0ad","source_pdf_url":"https://www.cai.cz/OA/pdf/286_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/286_2026_EN.pdf","has_de":true,"lab_division_de":"Kalibrierlabor Testo"},"methods":[{"_id":"ae854162ae5ee09c8bb0085f","lab_id":"6acfffe9ff06824761705e16","country":"CZ","accr_number":"2344","accr_body":"ČIA","row_label":"1","test_object":"Anemometry cyfrowe","test_object_en":"Digital anemometers","test_object_zh":"数字风速计","test_object_cs":"Číslicové anemometry","methodology":"Wzorcowanie – przepływ powietrza","methodology_en":"Calibration – airflow","methodology_zh":"校准 – 气流","methodology_cs":"Kalibrace – proudění vzduchu","parameters":[{"name":"","range":"od 0,1 m/s do 1,0 m/s","cmc":"0,09 m/s"},{"name":"","range":"od 1,0 m/s do 5,0 m/s","cmc":"0,18 m/s"},{"name":"","range":"od 5,0 m/s do 20 m/s","cmc":"0,20 m/s"},{"name":"","range":"od 20 m/s do 35 m/s","cmc":"0,35 m/s"}],"parameters_en":[{"name":"","range":"from 0,1 m/s to 1,0 m/s","cmc":"0,09 m/s"},{"name":"","range":"from 1,0 m/s to 5,0 m/s","cmc":"0,18 m/s"},{"name":"","range":"from 5,0 m/s to 20 m/s","cmc":"0,20 m/s"},{"name":"","range":"from 20 m/s to 35 m/s","cmc":"0,35 m/s"}],"parameters_zh":[{"name":"","range":"0,1 m/s 至 1,0 m/s","cmc":"0,09 m/s"},{"name":"","range":"1,0 m/s 至 5,0 m/s","cmc":"0,18 m/s"},{"name":"","range":"5,0 m/s 至 20 m/s","cmc":"0,20 m/s"},{"name":"","range":"20 m/s 至 35 m/s","cmc":"0,35 m/s"}],"parameters_cs":[{"name":"","range":"0,1 m/s až 1,0 m/s","cmc":"0,09 m/s"},{"name":"","range":"1,0 m/s až 5,0 m/s","cmc":"0,18 m/s"},{"name":"","range":"5,0 m/s až 20 m/s","cmc":"0,20 m/s"},{"name":"","range":"20 m/s až 35 m/s","cmc":"0,35 m/s"}],"technique":"Porównanie z wzorcem w tunelu aerodynamicznym","technique_en":"Comparison with a standard in a wind tunnel","technique_zh":"在风洞中与标准器比较","technique_cs":"Porovnání s etalonem v aerodynamickém tunelu","techniques":["Porównanie z wzorcem w tunelu aerodynamicznym"],"techniques_en":["Comparison with a standard in a wind tunnel"],"techniques_zh":["在风洞中与标准器比较"],"techniques_cs":["Porovnání s etalonem v aerodynamickém tunelu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – przepływ powietrza\nZakres:\nod 0,1 m/s do 1,0 m/s CMC 0,09 m/s\nod 1,0 m/s do 5,0 m/s CMC 0,18 m/s\nod 5,0 m/s do 20 m/s CMC 0,20 m/s\nod 20 m/s do 35 m/s CMC 0,35 m/s\nPorównanie z wzorcem w tunelu aerodynamicznym","reference":"KP-05","norm_bases":["KP-05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: przepływ powietrza","regulatory_area_en":"CMC for the field of measured quantity: Airflow","regulatory_area_zh":"被测量领域的CMC：气流","regulatory_area_cs":"CMC pro obor měřené veličiny: Proudění vzduchu","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Anemometry cyfrowe Wzorcowanie – przepływ powietrza Porównanie z wzorcem w tunelu aerodynamicznym od 0,1 m/s do 1,0 m/s CMC 0,09 m/s od 1,0 m/s do 5,0 m/s CMC 0,18 m/s od 5,0 m/s do 20 m/s CMC 0,20 m/s od 20 m/s do 35 m/s CMC 0,35 m/s Číslicové anemometry Kalibrace – proudění vzduchu Porovnání s etalonem v aerodynamickém tunelu 0,1 m/s až 1,0 m/s CMC 0,09 m/s 1,0 m/s až 5,0 m/s CMC 0,18 m/s 5,0 m/s až 20 m/s CMC 0,20 m/s 20 m/s až 35 m/s CMC 0,35 m/s KP-05 Anemometry cyfrowe Wzorcowanie – przeplyw powietrza Porownanie z wzorcem w tunelu aerodynamicznym od 0,1 m/s do 1,0 m/s CMC 0,09 m/s od 1,0 m/s do 5,0 m/s CMC 0,18 m/s od 5,0 m/s do 20 m/s CMC 0,20 m/s od 20 m/s do 35 m/s CMC 0,35 m/s Cislicove anemometry Kalibrace – proudeni vzduchu Porovnani s etalonem v aerodynamickem tunelu 0,1 m/s az 1,0 m/s CMC 0,09 m/s 1,0 m/s az 5,0 m/s CMC 0,18 m/s 5,0 m/s az 20 m/s CMC 0,20 m/s 20 m/s az 35 m/s CMC 0,35 m/s KP-05","search_en":"Digital anemometers Calibration – airflow Comparison with a standard in a wind tunnel CMC for the field of measured quantity: Airflow Comparison with a standard in a wind tunnel KP-05","search_zh":"数字风速计 校准 – 气流 在风洞中与标准器比较 被测量领域的CMC：气流 在风洞中与标准器比较 KP-05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","methodology_de":"Kalibrierung – Luftdurchfluss","parameters_de":[{"name":"","range":"von 0,1 m/s bis 1,0 m/s","cmc":"0,09 m/s"},{"name":"","range":"von 1,0 m/s bis 5,0 m/s","cmc":"0,18 m/s"},{"name":"","range":"von 5,0 m/s bis 20 m/s","cmc":"0,20 m/s"},{"name":"","range":"von 20 m/s bis 35 m/s","cmc":"0,35 m/s"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Luftdurchfluss","search_de":"Digitale Anemometer Kalibrierung – Luftdurchfluss Vergleich mit Normal im Windkanal CMC für den Messgrößenbereich: Luftdurchfluss Vergleich mit Normal im Windkanal KP-05","technique_de":"Vergleich mit Normal im Windkanal","techniques_de":["Vergleich mit Normal im Windkanal"],"test_object_de":"Digitale Anemometer"},{"_id":"d9b24a912a78a67b5e1af7ca","lab_id":"6acfffe9ff06824761705e16","country":"CZ","accr_number":"2344","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze cyfrowe","test_object_en":"Digital pressure gauges","test_object_zh":"数字压力计","test_object_cs":"Číslicové tlakoměry","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"podciśnienie, nadciśnienie, gaz","range":"od -400 hPa do 400 hPa","cmc":"1,2 hPa"}],"parameters_en":[{"name":"vacuum, gauge pressure, gas","range":"-400 hPa to 400 hPa","cmc":"1,2 hPa"}],"parameters_zh":[{"name":"负压、表压，气体","range":"-400 hPa 至 400 hPa","cmc":"1,2 hPa"}],"parameters_cs":[{"name":"podtlak, přetlak plyn","range":"-400 hPa až 400 hPa","cmc":"1,2 hPa"}],"technique":"Porównanie z cyfrowym ciśnieniomierzem wzorcowym","technique_en":"Comparison with a standard digital pressure gauge","technique_zh":"与标准数字压力计比较","technique_cs":"Porovnání s etalonovým digitálním tlakoměrem","techniques":["Porównanie z cyfrowym ciśnieniomierzem wzorcowym"],"techniques_en":["Comparison with a standard digital pressure gauge"],"techniques_zh":["与标准数字压力计比较"],"techniques_cs":["Porovnání s etalonovým digitálním tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\npodciśnienie, nadciśnienie, gaz od -400 hPa do 400 hPa CMC 1,2 hPa\nPorównanie z cyfrowym ciśnieniomierzem wzorcowym","reference":"KP-06","norm_bases":["KP-06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze cyfrowe Wzorcowanie – ciśnienie Porównanie z cyfrowym ciśnieniomierzem wzorcowym podciśnienie, nadciśnienie, gaz od -400 hPa do 400 hPa CMC 1,2 hPa Číslicové tlakoměry Kalibrace – tlak Porovnání s etalonovým digitálním tlakoměrem podtlak, přetlak plyn -400 hPa až 400 hPa CMC 1,2 hPa KP-06 Cisnieniomierze cyfrowe Wzorcowanie – cisnienie Porownanie z cyfrowym cisnieniomierzem wzorcowym podcisnienie, nadcisnienie, gaz od -400 hPa do 400 hPa CMC 1,2 hPa Cislicove tlakomery Kalibrace – tlak Porovnani s etalonovym digitalnim tlakomerem podtlak, pretlak plyn -400 hPa az 400 hPa CMC 1,2 hPa KP-06","search_en":"Digital pressure gauges Calibration – pressure Comparison with a standard digital pressure gauge CMC for the field of measured quantity: Pressure Comparison with a standard digital pressure gauge vacuum, gauge pressure, gas KP-06","search_zh":"数字压力计 校准 – 压力 与标准数字压力计比较 被测量领域的CMC：压力 与标准数字压力计比较 负压、表压，气体 KP-06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","methodology_de":"Kalibrierung – Druck","parameters_de":[{"name":"Unterdruck, Überdruck, Gas","range":"von -400 hPa bis 400 hPa","cmc":"1,2 hPa"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Druck","search_de":"Digitale Druckmessgeräte Kalibrierung – Druck Vergleich mit digitalem Referenz-Druckmessgerät CMC für den Messgrößenbereich: Druck Vergleich mit digitalem Referenz-Druckmessgerät Unterdruck, Überdruck, Gas KP-06","technique_de":"Vergleich mit digitalem Referenz-Druckmessgerät","techniques_de":["Vergleich mit digitalem Referenz-Druckmessgerät"],"test_object_de":"Digitale Druckmessgeräte"},{"_id":"fb61ecf4555d84a14a4dea18","lab_id":"6acfffe9ff06824761705e16","country":"CZ","accr_number":"2344","accr_body":"ČIA","row_label":"2","test_object":"Ciśnieniomierze cyfrowe","test_object_en":"Digital pressure gauges","test_object_zh":"数字压力计","test_object_cs":"Číslicové tlakoměry","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"nadciśnienie, gaz","range":"od 0 bar do 10 bar","cmc":"0,02 bar"},{"name":"nadciśnienie, gaz","range":"od 10 bar do 50 bar","cmc":"0,03 bar"},{"name":"nadciśnienie, gaz","range":"od 50 bar do 60 bar","cmc":"0,04 bar"}],"parameters_en":[{"name":"gauge pressure, gas","range":"0 bar to 10 bar","cmc":"0,02 bar"},{"name":"gauge pressure, gas","range":"10 bar to 50 bar","cmc":"0,03 bar"},{"name":"gauge pressure, gas","range":"50 bar to 60 bar","cmc":"0,04 bar"}],"parameters_zh":[{"name":"表压，气体","range":"0 bar 至 10 bar","cmc":"0,02 bar"},{"name":"表压，气体","range":"10 bar 至 50 bar","cmc":"0,03 bar"},{"name":"表压，气体","range":"50 bar 至 60 bar","cmc":"0,04 bar"}],"parameters_cs":[{"name":"přetlak, plyn","range":"0 bar až 10 bar","cmc":"0,02 bar"},{"name":"přetlak, plyn","range":"10 bar až 50 bar","cmc":"0,03 bar"},{"name":"přetlak, plyn","range":"50 bar až 60 bar","cmc":"0,04 bar"}],"technique":"Porównanie z cyfrowym ciśnieniomierzem wzorcowym","technique_en":"Comparison with a standard digital pressure gauge","technique_zh":"与标准数字压力计比较","technique_cs":"Porovnání s etalonovým digitálním tlakoměrem","techniques":["Porównanie z cyfrowym ciśnieniomierzem wzorcowym"],"techniques_en":["Comparison with a standard digital pressure gauge"],"techniques_zh":["与标准数字压力计比较"],"techniques_cs":["Porovnání s etalonovým digitálním tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nnadciśnienie, gaz od 0 bar do 10 bar CMC 0,02 bar\nnadciśnienie, gaz od 10 bar do 50 bar CMC 0,03 bar\nnadciśnienie, gaz od 50 bar do 60 bar CMC 0,04 bar\nPorównanie z cyfrowym ciśnieniomierzem wzorcowym","reference":"KP-06","norm_bases":["KP-06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze cyfrowe Wzorcowanie – ciśnienie Porównanie z cyfrowym ciśnieniomierzem wzorcowym nadciśnienie, gaz od 0 bar do 10 bar CMC 0,02 bar nadciśnienie, gaz od 10 bar do 50 bar CMC 0,03 bar nadciśnienie, gaz od 50 bar do 60 bar CMC 0,04 bar Číslicové tlakoměry Kalibrace – tlak Porovnání s etalonovým digitálním tlakoměrem přetlak, plyn 0 bar až 10 bar CMC 0,02 bar přetlak, plyn 10 bar až 50 bar CMC 0,03 bar přetlak, plyn 50 bar až 60 bar CMC 0,04 bar KP-06 Cisnieniomierze cyfrowe Wzorcowanie – cisnienie Porownanie z cyfrowym cisnieniomierzem wzorcowym nadcisnienie, gaz od 0 bar do 10 bar CMC 0,02 bar nadcisnienie, gaz od 10 bar do 50 bar CMC 0,03 bar nadcisnienie, gaz od 50 bar do 60 bar CMC 0,04 bar Cislicove tlakomery Kalibrace – tlak Porovnani s etalonovym digitalnim tlakomerem pretlak, plyn 0 bar az 10 bar CMC 0,02 bar pretlak, plyn 10 bar az 50 bar CMC 0,03 bar pretlak, plyn 50 bar az 60 bar CMC 0,04 bar KP-06","search_en":"Digital pressure gauges Calibration – pressure Comparison with a standard digital pressure gauge CMC for the field of measured quantity: Pressure Comparison with a standard digital pressure gauge gauge pressure, gas gauge pressure, gas gauge pressure, gas KP-06","search_zh":"数字压力计 校准 – 压力 与标准数字压力计比较 被测量领域的CMC：压力 与标准数字压力计比较 表压，气体 表压，气体 表压，气体 KP-06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","methodology_de":"Kalibrierung – Druck","parameters_de":[{"name":"Überdruck, Gas","range":"von 0 bar bis 10 bar","cmc":"0,02 bar"},{"name":"Überdruck, Gas","range":"von 10 bar bis 50 bar","cmc":"0,03 bar"},{"name":"Überdruck, Gas","range":"von 50 bar bis 60 bar","cmc":"0,04 bar"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Druck","search_de":"Digitale Druckmessgeräte Kalibrierung – Druck Vergleich mit digitalem Referenz-Druckmessgerät CMC für den Messgrößenbereich: Druck Vergleich mit digitalem Referenz-Druckmessgerät Überdruck, Gas Überdruck, Gas Überdruck, Gas KP-06","technique_de":"Vergleich mit digitalem Referenz-Druckmessgerät","techniques_de":["Vergleich mit digitalem Referenz-Druckmessgerät"],"test_object_de":"Digitale Druckmessgeräte"},{"_id":"65a2e0fffa9d03e1aa26ec2c","lab_id":"6acfffe9ff06824761705e16","country":"CZ","accr_number":"2344","accr_body":"ČIA","row_label":"1","test_object":"Termometry cyfrowe","test_object_en":"Digital thermometers","test_object_zh":"数字温度计","test_object_cs":"Číslicové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -90 °C do -80 °C","cmc":"0,50 °C"},{"name":"","range":"od -80 °C do -40 °C","cmc":"0,30 °C"},{"name":"","range":"od -40 °C do -30 °C","cmc":"0,15 °C"},{"name":"","range":"od -30 °C do 120 °C","cmc":"0,06 °C"},{"name":"","range":"od 120 °C do 250 °C","cmc":"0,13 °C"},{"name":"","range":"od 250 °C do 300 °C","cmc":"0,15 °C"},{"name":"","range":"od 300 °C do 400 °C","cmc":"0,30 °C"},{"name":"","range":"od 400 °C do 450 °C","cmc":"0,50 °C"},{"name":"","range":"od 450 °C do 600 °C","cmc":"0,65 °C"}],"parameters_en":[{"name":"","range":"from -90 °C to -80 °C","cmc":"0,50 °C"},{"name":"","range":"from -80 °C to -40 °C","cmc":"0,30 °C"},{"name":"","range":"from -40 °C to -30 °C","cmc":"0,15 °C"},{"name":"","range":"from -30 °C to 120 °C","cmc":"0,06 °C"},{"name":"","range":"from 120 °C to 250 °C","cmc":"0,13 °C"},{"name":"","range":"from 250 °C to 300 °C","cmc":"0,15 °C"},{"name":"","range":"from 300 °C to 400 °C","cmc":"0,30 °C"},{"name":"","range":"from 400 °C to 450 °C","cmc":"0,50 °C"},{"name":"","range":"from 450 °C to 600 °C","cmc":"0,65 °C"}],"parameters_zh":[{"name":"","range":"-90 °C 至 -80 °C","cmc":"0,50 °C"},{"name":"","range":"-80 °C 至 -40 °C","cmc":"0,30 °C"},{"name":"","range":"-40 °C 至 -30 °C","cmc":"0,15 °C"},{"name":"","range":"-30 °C 至 120 °C","cmc":"0,06 °C"},{"name":"","range":"120 °C 至 250 °C","cmc":"0,13 °C"},{"name":"","range":"250 °C 至 300 °C","cmc":"0,15 °C"},{"name":"","range":"300 °C 至 400 °C","cmc":"0,30 °C"},{"name":"","range":"400 °C 至 450 °C","cmc":"0,50 °C"},{"name":"","range":"450 °C 至 600 °C","cmc":"0,65 °C"}],"parameters_cs":[{"name":"","range":"-90 °C až -80 °C","cmc":"0,50 °C"},{"name":"","range":"-80 °C až -40 °C","cmc":"0,30 °C"},{"name":"","range":"-40 °C až -30 °C","cmc":"0,15 °C"},{"name":"","range":"-30 °C až 120 °C","cmc":"0,06 °C"},{"name":"","range":"120 °C až 250 °C","cmc":"0,13 °C"},{"name":"","range":"250 °C až 300 °C","cmc":"0,15 °C"},{"name":"","range":"300 °C až 400 °C","cmc":"0,30 °C"},{"name":"","range":"400 °C až 450 °C","cmc":"0,50 °C"},{"name":"","range":"450 °C až 600 °C","cmc":"0,65 °C"}],"technique":"-90 °C do -30 °C i 250 °C do 600 °C: porównanie z cyfrowym termometrem wzorcowym w kalibratorze blokowym; -30 °C do 250 °C: porównanie z cyfrowym termometrem wzorcowym w łaźni termostatycznej","technique_en":"-90 °C to -30 °C and 250 °C to 600 °C: comparison with a standard digital thermometer in a dry block; -30 °C to 250 °C: comparison with a standard digital thermometer in a thermostatic bath","technique_zh":"-90 °C 至 -30 °C 和 250 °C 至 600 °C：在干体炉中与标准数字温度计比较；-30 °C 至 250 °C：在恒温槽中与标准数字温度计比较","technique_cs":"-90 °C až -30 °C a 250 °C až 600 °C: Porovnání s etalonovým digitálním teploměrem v blokové peci; -30 °C až 250 °C: Porovnání s etalonovým digitálním teploměrem v termostatické lázni","techniques":["-90 °C do -30 °C i 250 °C do 600 °C: porównanie z cyfrowym termometrem wzorcowym w kalibratorze blokowym; -30 °C do 250 °C: porównanie z cyfrowym termometrem wzorcowym w łaźni termostatycznej"],"techniques_en":["-90 °C to -30 °C and 250 °C to 600 °C: comparison with a standard digital thermometer in a dry block; -30 °C to 250 °C: comparison with a standard digital thermometer in a thermostatic bath"],"techniques_zh":["-90 °C 至 -30 °C 和 250 °C 至 600 °C：在干体炉中与标准数字温度计比较；-30 °C 至 250 °C：在恒温槽中与标准数字温度计比较"],"techniques_cs":["-90 °C až -30 °C a 250 °C až 600 °C: Porovnání s etalonovým digitálním teploměrem v blokové peci; -30 °C až 250 °C: Porovnání s etalonovým digitálním teploměrem v termostatické lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -90 °C do -80 °C CMC 0,50 °C\nod -80 °C do -40 °C CMC 0,30 °C\nod -40 °C do -30 °C CMC 0,15 °C\nod -30 °C do 120 °C CMC 0,06 °C\nod 120 °C do 250 °C CMC 0,13 °C\nod 250 °C do 300 °C CMC 0,15 °C\nod 300 °C do 400 °C CMC 0,30 °C\nod 400 °C do 450 °C CMC 0,50 °C\nod 450 °C do 600 °C CMC 0,65 °C\n-90 °C do -30 °C i 250 °C do 600 °C: porównanie z cyfrowym termometrem wzorcowym w kalibratorze blokowym; -30 °C do 250 °C: porównanie z cyfrowym termometrem wzorcowym w łaźni termostatycznej","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry cyfrowe Wzorcowanie – temperatura -90 °C do -30 °C i 250 °C do 600 °C: porównanie z cyfrowym termometrem wzorcowym w kalibratorze blokowym; -30 °C do 250 °C: porównanie z cyfrowym termometrem wzorcowym w łaźni termostatycznej od -90 °C do -80 °C CMC 0,50 °C od -80 °C do -40 °C CMC 0,30 °C od -40 °C do -30 °C CMC 0,15 °C od -30 °C do 120 °C CMC 0,06 °C od 120 °C do 250 °C CMC 0,13 °C od 250 °C do 300 °C CMC 0,15 °C od 300 °C do 400 °C CMC 0,30 °C od 400 °C do 450 °C CMC 0,50 °C od 450 °C do 600 °C CMC 0,65 °C Číslicové teploměry Kalibrace – teplota -90 °C až -30 °C a 250 °C až 600 °C: Porovnání s etalonovým digitálním teploměrem v blokové peci; -30 °C až 250 °C: Porovnání s etalonovým digitálním teploměrem v termostatické lázni -90 °C až -80 °C CMC 0,50 °C -80 °C až -40 °C CMC 0,30 °C -40 °C až -30 °C CMC 0,15 °C -30 °C až 120 °C CMC 0,06 °C 120 °C až 250 °C CMC 0,13 °C 250 °C až 300 °C CMC 0,15 °C 300 °C až 400 °C CMC 0,30 °C 400 °C až 450 °C CMC 0,50 °C 450 °C až 600 °C CMC 0,65 °C KP-01 Termometry cyfrowe Wzorcowanie – temperatura -90 °C do -30 °C i 250 °C do 600 °C: porownanie z cyfrowym termometrem wzorcowym w kalibratorze blokowym; -30 °C do 250 °C: porownanie z cyfrowym termometrem wzorcowym w lazni termostatycznej od -90 °C do -80 °C CMC 0,50 °C od -80 °C do -40 °C CMC 0,30 °C od -40 °C do -30 °C CMC 0,15 °C od -30 °C do 120 °C CMC 0,06 °C od 120 °C do 250 °C CMC 0,13 °C od 250 °C do 300 °C CMC 0,15 °C od 300 °C do 400 °C CMC 0,30 °C od 400 °C do 450 °C CMC 0,50 °C od 450 °C do 600 °C CMC 0,65 °C Cislicove teplomery Kalibrace – teplota -90 °C az -30 °C a 250 °C az 600 °C: Porovnani s etalonovym digitalnim teplomerem v blokove peci; -30 °C az 250 °C: Porovnani s etalonovym digitalnim teplomerem v termostaticke lazni -90 °C az -80 °C CMC 0,50 °C -80 °C az -40 °C CMC 0,30 °C -40 °C az -30 °C CMC 0,15 °C -30 °C az 120 °C CMC 0,06 °C 120 °C az 250 °C CMC 0,13 °C 250 °C az 300 °C CMC 0,15 °C 300 °C az 400 °C CMC 0,30 °C 400 °C az 450 °C CMC 0,50 °C 450 °C az 600 °C CMC 0,65 °C KP-01","search_en":"Digital thermometers Calibration – temperature -90 °C to -30 °C and 250 °C to 600 °C: comparison with a standard digital thermometer in a dry block; -30 °C to 250 °C: comparison with a standard digital thermometer in a thermostatic bath CMC for the field of measured quantity: Temperature -90 °C to -30 °C and 250 °C to 600 °C: comparison with a standard digital thermometer in a dry block; -30 °C to 250 °C: comparison with a standard digital thermometer in a thermostatic bath KP-01","search_zh":"数字温度计 校准 – 温度 -90 °C 至 -30 °C 和 250 °C 至 600 °C：在干体炉中与标准数字温度计比较；-30 °C 至 250 °C：在恒温槽中与标准数字温度计比较 被测量领域的CMC：温度 -90 °C 至 -30 °C 和 250 °C 至 600 °C：在干体炉中与标准数字温度计比较；-30 °C 至 250 °C：在恒温槽中与标准数字温度计比较 KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von -90 °C bis -80 °C","cmc":"0,50 °C"},{"name":"","range":"von -80 °C bis -40 °C","cmc":"0,30 °C"},{"name":"","range":"von -40 °C bis -30 °C","cmc":"0,15 °C"},{"name":"","range":"von -30 °C bis 120 °C","cmc":"0,06 °C"},{"name":"","range":"von 120 °C bis 250 °C","cmc":"0,13 °C"},{"name":"","range":"von 250 °C bis 300 °C","cmc":"0,15 °C"},{"name":"","range":"von 300 °C bis 400 °C","cmc":"0,30 °C"},{"name":"","range":"von 400 °C bis 450 °C","cmc":"0,50 °C"},{"name":"","range":"von 450 °C bis 600 °C","cmc":"0,65 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Digitalthermometer Kalibrierung – Temperatur -90 °C bis -30 °C und 250 °C bis 600 °C: Vergleich mit einem digitalen Normalthermometer im Blockkalibrator; -30 °C bis 250 °C: Vergleich mit einem digitalen Normalthermometer im Thermostatbad CMC für den Messgrößenbereich: Temperatur -90 °C bis -30 °C und 250 °C bis 600 °C: Vergleich mit einem digitalen Normalthermometer im Blockkalibrator; -30 °C bis 250 °C: Vergleich mit einem digitalen Normalthermometer im Thermostatbad KP-01","technique_de":"-90 °C bis -30 °C und 250 °C bis 600 °C: Vergleich mit einem digitalen Normalthermometer im Blockkalibrator; -30 °C bis 250 °C: Vergleich mit einem digitalen Normalthermometer im Thermostatbad","techniques_de":["-90 °C bis -30 °C und 250 °C bis 600 °C: Vergleich mit einem digitalen Normalthermometer im Blockkalibrator; -30 °C bis 250 °C: Vergleich mit einem digitalen Normalthermometer im Thermostatbad"],"test_object_de":"Digitalthermometer"},{"_id":"0de2665d9834864a83e25f06","lab_id":"6acfffe9ff06824761705e16","country":"CZ","accr_number":"2344","accr_body":"ČIA","row_label":"2","test_object":"Cyfrowe termometry stykowe","test_object_en":"Contact digital thermometers","test_object_zh":"数字接触式温度计","test_object_cs":"Dotykové číslicové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -20 °C do 25 °C","cmc":"1,5 °C"},{"name":"","range":"od 25 °C do 100 °C","cmc":"1,0 °C"},{"name":"","range":"od 100 °C do 150 °C","cmc":"1,5 °C"},{"name":"","range":"od 150 °C do 200 °C","cmc":"2,0 °C"},{"name":"","range":"od 200 °C do 250 °C","cmc":"2,5 °C"},{"name":"","range":"od 250 °C do 300 °C","cmc":"3,0 °C"}],"parameters_en":[{"name":"","range":"from -20 °C to 25 °C","cmc":"1,5 °C"},{"name":"","range":"from 25 °C to 100 °C","cmc":"1,0 °C"},{"name":"","range":"from 100 °C to 150 °C","cmc":"1,5 °C"},{"name":"","range":"from 150 °C to 200 °C","cmc":"2,0 °C"},{"name":"","range":"from 200 °C to 250 °C","cmc":"2,5 °C"},{"name":"","range":"from 250 °C to 300 °C","cmc":"3,0 °C"}],"parameters_zh":[{"name":"","range":"-20 °C 至 25 °C","cmc":"1,5 °C"},{"name":"","range":"25 °C 至 100 °C","cmc":"1,0 °C"},{"name":"","range":"100 °C 至 150 °C","cmc":"1,5 °C"},{"name":"","range":"150 °C 至 200 °C","cmc":"2,0 °C"},{"name":"","range":"200 °C 至 250 °C","cmc":"2,5 °C"},{"name":"","range":"250 °C 至 300 °C","cmc":"3,0 °C"}],"parameters_cs":[{"name":"","range":"-20 °C až 25 °C","cmc":"1,5 °C"},{"name":"","range":"25 °C až 100 °C","cmc":"1,0 °C"},{"name":"","range":"100 °C až 150 °C","cmc":"1,5 °C"},{"name":"","range":"150 °C až 200 °C","cmc":"2,0 °C"},{"name":"","range":"200 °C až 250 °C","cmc":"2,5 °C"},{"name":"","range":"250 °C až 300 °C","cmc":"3,0 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym na aluminiowej płycie stykowej","technique_en":"Comparison with a standard digital thermometer on an aluminium contact plate","technique_zh":"在铝制接触板上与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem na hliníkové dotykové desce","techniques":["Porównanie z cyfrowym termometrem wzorcowym na aluminiowej płycie stykowej"],"techniques_en":["Comparison with a standard digital thermometer on an aluminium contact plate"],"techniques_zh":["在铝制接触板上与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem na hliníkové dotykové desce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -20 °C do 25 °C CMC 1,5 °C\nod 25 °C do 100 °C CMC 1,0 °C\nod 100 °C do 150 °C CMC 1,5 °C\nod 150 °C do 200 °C CMC 2,0 °C\nod 200 °C do 250 °C CMC 2,5 °C\nod 250 °C do 300 °C CMC 3,0 °C\nPorównanie z cyfrowym termometrem wzorcowym na aluminiowej płycie stykowej","reference":"KP-02","norm_bases":["KP-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Cyfrowe termometry stykowe Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym na aluminiowej płycie stykowej od -20 °C do 25 °C CMC 1,5 °C od 25 °C do 100 °C CMC 1,0 °C od 100 °C do 150 °C CMC 1,5 °C od 150 °C do 200 °C CMC 2,0 °C od 200 °C do 250 °C CMC 2,5 °C od 250 °C do 300 °C CMC 3,0 °C Dotykové číslicové teploměry Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem na hliníkové dotykové desce -20 °C až 25 °C CMC 1,5 °C 25 °C až 100 °C CMC 1,0 °C 100 °C až 150 °C CMC 1,5 °C 150 °C až 200 °C CMC 2,0 °C 200 °C až 250 °C CMC 2,5 °C 250 °C až 300 °C CMC 3,0 °C KP-02 Cyfrowe termometry stykowe Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym na aluminiowej plycie stykowej od -20 °C do 25 °C CMC 1,5 °C od 25 °C do 100 °C CMC 1,0 °C od 100 °C do 150 °C CMC 1,5 °C od 150 °C do 200 °C CMC 2,0 °C od 200 °C do 250 °C CMC 2,5 °C od 250 °C do 300 °C CMC 3,0 °C Dotykove cislicove teplomery Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem na hlinikove dotykove desce -20 °C az 25 °C CMC 1,5 °C 25 °C az 100 °C CMC 1,0 °C 100 °C az 150 °C CMC 1,5 °C 150 °C az 200 °C CMC 2,0 °C 200 °C az 250 °C CMC 2,5 °C 250 °C az 300 °C CMC 3,0 °C KP-02","search_en":"Contact digital thermometers Calibration – temperature Comparison with a standard digital thermometer on an aluminium contact plate CMC for the field of measured quantity: Temperature Comparison with a standard digital thermometer on an aluminium contact plate KP-02","search_zh":"数字接触式温度计 校准 – 温度 在铝制接触板上与标准数字温度计比较 被测量领域的CMC：温度 在铝制接触板上与标准数字温度计比较 KP-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von -20 °C bis 25 °C","cmc":"1,5 °C"},{"name":"","range":"von 25 °C bis 100 °C","cmc":"1,0 °C"},{"name":"","range":"von 100 °C bis 150 °C","cmc":"1,5 °C"},{"name":"","range":"von 150 °C bis 200 °C","cmc":"2,0 °C"},{"name":"","range":"von 200 °C bis 250 °C","cmc":"2,5 °C"},{"name":"","range":"von 250 °C bis 300 °C","cmc":"3,0 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Digitale Berührungsthermometer Kalibrierung – Temperatur Vergleich mit dem digitalen Normalthermometer auf einer Aluminium-Kontaktplatte CMC für den Messgrößenbereich: Temperatur Vergleich mit dem digitalen Normalthermometer auf einer Aluminium-Kontaktplatte KP-02","technique_de":"Vergleich mit dem digitalen Normalthermometer auf einer Aluminium-Kontaktplatte","techniques_de":["Vergleich mit dem digitalen Normalthermometer auf einer Aluminium-Kontaktplatte"],"test_object_de":"Digitale Berührungsthermometer"},{"_id":"0c6e97d74523dfb03081b643","lab_id":"6acfffe9ff06824761705e16","country":"CZ","accr_number":"2344","accr_body":"ČIA","row_label":"3","test_object":"Bezdotykowe termometry cyfrowe i kamery termowizyjne w trybie pirometru","test_object_en":"Contactless digital thermometers and thermal cameras in pyrometer mode","test_object_zh":"非接触式数字温度计和高温计模式下的热像仪","test_object_cs":"Bezdotykové číslicové teploměry a termokamery v režimu pyrometru","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do -10 °C","cmc":"2,7 °C"},{"name":"","range":"od -10 °C do 0 °C","cmc":"2,0 °C"},{"name":"","range":"od 0 °C do 35 °C","cmc":"1,5 °C"},{"name":"","range":"od 35 °C do 90 °C","cmc":"1,8 °C"},{"name":"","range":"od 90 °C do 120 °C","cmc":"2,2 °C"},{"name":"","range":"od 120 °C do 150 °C","cmc":"2,5 °C"},{"name":"","range":"od 150 °C do 200 °C","cmc":"3,0 °C"},{"name":"","range":"od 200 °C do 400 °C","cmc":"4,5 °C"},{"name":"","range":"od 400 °C do 500 °C","cmc":"5,5 °C"}],"parameters_en":[{"name":"","range":"from -30 °C to -10 °C","cmc":"2,7 °C"},{"name":"","range":"from -10 °C to 0 °C","cmc":"2,0 °C"},{"name":"","range":"from 0 °C to 35 °C","cmc":"1,5 °C"},{"name":"","range":"from 35 °C to 90 °C","cmc":"1,8 °C"},{"name":"","range":"from 90 °C to 120 °C","cmc":"2,2 °C"},{"name":"","range":"from 120 °C to 150 °C","cmc":"2,5 °C"},{"name":"","range":"from 150 °C to 200 °C","cmc":"3,0 °C"},{"name":"","range":"from 200 °C to 400 °C","cmc":"4,5 °C"},{"name":"","range":"from 400 °C to 500 °C","cmc":"5,5 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 -10 °C","cmc":"2,7 °C"},{"name":"","range":"-10 °C 至 0 °C","cmc":"2,0 °C"},{"name":"","range":"0 °C 至 35 °C","cmc":"1,5 °C"},{"name":"","range":"35 °C 至 90 °C","cmc":"1,8 °C"},{"name":"","range":"90 °C 至 120 °C","cmc":"2,2 °C"},{"name":"","range":"120 °C 至 150 °C","cmc":"2,5 °C"},{"name":"","range":"150 °C 至 200 °C","cmc":"3,0 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"4,5 °C"},{"name":"","range":"400 °C 至 500 °C","cmc":"5,5 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až -10 °C","cmc":"2,7 °C"},{"name":"","range":"-10 °C až 0 °C","cmc":"2,0 °C"},{"name":"","range":"0 °C až 35 °C","cmc":"1,5 °C"},{"name":"","range":"35 °C až 90 °C","cmc":"1,8 °C"},{"name":"","range":"90 °C až 120 °C","cmc":"2,2 °C"},{"name":"","range":"120 °C až 150 °C","cmc":"2,5 °C"},{"name":"","range":"150 °C až 200 °C","cmc":"3,0 °C"},{"name":"","range":"200 °C až 400 °C","cmc":"4,5 °C"},{"name":"","range":"400 °C až 500 °C","cmc":"5,5 °C"}],"technique":"Porównanie z wzorcowym ciałem szarym","technique_en":"Comparison with a standard gray body","technique_zh":"与标准灰体比较","technique_cs":"Porovnání s etalonovým šedým tělesem","techniques":["Porównanie z wzorcowym ciałem szarym"],"techniques_en":["Comparison with a standard gray body"],"techniques_zh":["与标准灰体比较"],"techniques_cs":["Porovnání s etalonovým šedým tělesem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do -10 °C CMC 2,7 °C\nod -10 °C do 0 °C CMC 2,0 °C\nod 0 °C do 35 °C CMC 1,5 °C\nod 35 °C do 90 °C CMC 1,8 °C\nod 90 °C do 120 °C CMC 2,2 °C\nod 120 °C do 150 °C CMC 2,5 °C\nod 150 °C do 200 °C CMC 3,0 °C\nod 200 °C do 400 °C CMC 4,5 °C\nod 400 °C do 500 °C CMC 5,5 °C\nPorównanie z wzorcowym ciałem szarym","reference":"KP-03","norm_bases":["KP-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Bezdotykowe termometry cyfrowe i kamery termowizyjne w trybie pirometru Wzorcowanie – temperatura Porównanie z wzorcowym ciałem szarym od -30 °C do -10 °C CMC 2,7 °C od -10 °C do 0 °C CMC 2,0 °C od 0 °C do 35 °C CMC 1,5 °C od 35 °C do 90 °C CMC 1,8 °C od 90 °C do 120 °C CMC 2,2 °C od 120 °C do 150 °C CMC 2,5 °C od 150 °C do 200 °C CMC 3,0 °C od 200 °C do 400 °C CMC 4,5 °C od 400 °C do 500 °C CMC 5,5 °C Bezdotykové číslicové teploměry a termokamery v režimu pyrometru Kalibrace – teplota Porovnání s etalonovým šedým tělesem -30 °C až -10 °C CMC 2,7 °C -10 °C až 0 °C CMC 2,0 °C 0 °C až 35 °C CMC 1,5 °C 35 °C až 90 °C CMC 1,8 °C 90 °C až 120 °C CMC 2,2 °C 120 °C až 150 °C CMC 2,5 °C 150 °C až 200 °C CMC 3,0 °C 200 °C až 400 °C CMC 4,5 °C 400 °C až 500 °C CMC 5,5 °C KP-03 Bezdotykowe termometry cyfrowe i kamery termowizyjne w trybie pirometru Wzorcowanie – temperatura Porownanie z wzorcowym cialem szarym od -30 °C do -10 °C CMC 2,7 °C od -10 °C do 0 °C CMC 2,0 °C od 0 °C do 35 °C CMC 1,5 °C od 35 °C do 90 °C CMC 1,8 °C od 90 °C do 120 °C CMC 2,2 °C od 120 °C do 150 °C CMC 2,5 °C od 150 °C do 200 °C CMC 3,0 °C od 200 °C do 400 °C CMC 4,5 °C od 400 °C do 500 °C CMC 5,5 °C Bezdotykove cislicove teplomery a termokamery v rezimu pyrometru Kalibrace – teplota Porovnani s etalonovym sedym telesem -30 °C az -10 °C CMC 2,7 °C -10 °C az 0 °C CMC 2,0 °C 0 °C az 35 °C CMC 1,5 °C 35 °C az 90 °C CMC 1,8 °C 90 °C az 120 °C CMC 2,2 °C 120 °C az 150 °C CMC 2,5 °C 150 °C az 200 °C CMC 3,0 °C 200 °C az 400 °C CMC 4,5 °C 400 °C az 500 °C CMC 5,5 °C KP-03","search_en":"Contactless digital thermometers and thermal cameras in pyrometer mode Calibration – temperature Comparison with a standard gray body CMC for the field of measured quantity: Temperature Comparison with a standard gray body KP-03","search_zh":"非接触式数字温度计和高温计模式下的热像仪 校准 – 温度 与标准灰体比较 被测量领域的CMC：温度 与标准灰体比较 KP-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von -30 °C bis -10 °C","cmc":"2,7 °C"},{"name":"","range":"von -10 °C bis 0 °C","cmc":"2,0 °C"},{"name":"","range":"von 0 °C bis 35 °C","cmc":"1,5 °C"},{"name":"","range":"von 35 °C bis 90 °C","cmc":"1,8 °C"},{"name":"","range":"von 90 °C bis 120 °C","cmc":"2,2 °C"},{"name":"","range":"von 120 °C bis 150 °C","cmc":"2,5 °C"},{"name":"","range":"von 150 °C bis 200 °C","cmc":"3,0 °C"},{"name":"","range":"von 200 °C bis 400 °C","cmc":"4,5 °C"},{"name":"","range":"von 400 °C bis 500 °C","cmc":"5,5 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Berührungslose Digitalthermometer und Wärmebildkameras im Pyrometermodus Kalibrierung – Temperatur Vergleich mit grauem Normalstrahler CMC für den Messgrößenbereich: Temperatur Vergleich mit grauem Normalstrahler KP-03","technique_de":"Vergleich mit grauem Normalstrahler","techniques_de":["Vergleich mit grauem Normalstrahler"],"test_object_de":"Berührungslose Digitalthermometer und Wärmebildkameras im Pyrometermodus"},{"_id":"efefe6a80225bdc263c76c04","lab_id":"6acfffe9ff06824761705e16","country":"CZ","accr_number":"2344","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność względna / wilgotnościomierze cyfrowe","test_object_en":"Relative air humidity / digital hygrometers","test_object_zh":"相对湿度 / 数字湿度计","test_object_cs":"Relativní vlhkost / Číslicové vlhkoměry","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"(20 do 30) °C","range":"od 5 % RH do 35 % RH","cmc":"0,6 % RH"},{"name":"(20 do 30) °C","range":"od 35 % RH do 75 % RH","cmc":"0,8 % RH"},{"name":"(20 do 30) °C","range":"od 75 % RH do 90 % RH","cmc":"1,0 % RH"},{"name":"(20 do 30) °C","range":"od 90 % RH do 95 % RH","cmc":"1,5 % RH"}],"parameters_en":[{"name":"(20 to 30) °C","range":"5 % RH to 35 % RH","cmc":"0,6 % RH"},{"name":"(20 to 30) °C","range":"35 % RH to 75 % RH","cmc":"0,8 % RH"},{"name":"(20 to 30) °C","range":"75 % RH to 90 % RH","cmc":"1,0 % RH"},{"name":"(20 to 30) °C","range":"90 % RH to 95 % RH","cmc":"1,5 % RH"}],"parameters_zh":[{"name":"(20 至 30) °C","range":"5 % RH 至 35 % RH","cmc":"0,6 % RH"},{"name":"(20 至 30) °C","range":"35 % RH 至 75 % RH","cmc":"0,8 % RH"},{"name":"(20 至 30) °C","range":"75 % RH 至 90 % RH","cmc":"1,0 % RH"},{"name":"(20 至 30) °C","range":"90 % RH 至 95 % RH","cmc":"1,5 % RH"}],"parameters_cs":[{"name":"(20 až 30) °C","range":"5 % RH až 35 % RH","cmc":"0,6 % RH"},{"name":"(20 až 30) °C","range":"35 % RH až 75 % RH","cmc":"0,8 % RH"},{"name":"(20 až 30) °C","range":"75 % RH až 90 % RH","cmc":"1,0 % RH"},{"name":"(20 až 30) °C","range":"90 % RH až 95 % RH","cmc":"1,5 % RH"}],"technique":"Porównanie z wzorcowym higrometrem punktu rosy w generatorze wilgotności","technique_en":"Comparison with a standard dew point hygrometer in a humidity generator","technique_zh":"在湿度发生器中与标准露点湿度计比较","technique_cs":"Porovnání s etalonovým rosnobodovým vlhkoměrem v generátoru vlhkosti","techniques":["Porównanie z wzorcowym higrometrem punktu rosy w generatorze wilgotności"],"techniques_en":["Comparison with a standard dew point hygrometer in a humidity generator"],"techniques_zh":["在湿度发生器中与标准露点湿度计比较"],"techniques_cs":["Porovnání s etalonovým rosnobodovým vlhkoměrem v generátoru vlhkosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\n(20 do 30) °C od 5 % RH do 35 % RH CMC 0,6 % RH\n(20 do 30) °C od 35 % RH do 75 % RH CMC 0,8 % RH\n(20 do 30) °C od 75 % RH do 90 % RH CMC 1,0 % RH\n(20 do 30) °C od 90 % RH do 95 % RH CMC 1,5 % RH\nPorównanie z wzorcowym higrometrem punktu rosy w generatorze wilgotności","reference":"KP-04","norm_bases":["KP-04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność względna / wilgotnościomierze cyfrowe Wzorcowanie – wilgotność powietrza Porównanie z wzorcowym higrometrem punktu rosy w generatorze wilgotności (20 do 30) °C od 5 % RH do 35 % RH CMC 0,6 % RH (20 do 30) °C od 35 % RH do 75 % RH CMC 0,8 % RH (20 do 30) °C od 75 % RH do 90 % RH CMC 1,0 % RH (20 do 30) °C od 90 % RH do 95 % RH CMC 1,5 % RH Relativní vlhkost / Číslicové vlhkoměry Kalibrace – vlhkost vzduchu Porovnání s etalonovým rosnobodovým vlhkoměrem v generátoru vlhkosti (20 až 30) °C 5 % RH až 35 % RH CMC 0,6 % RH (20 až 30) °C 35 % RH až 75 % RH CMC 0,8 % RH (20 až 30) °C 75 % RH až 90 % RH CMC 1,0 % RH (20 až 30) °C 90 % RH až 95 % RH CMC 1,5 % RH KP-04 Wilgotnosc wzgledna / wilgotnosciomierze cyfrowe Wzorcowanie – wilgotnosc powietrza Porownanie z wzorcowym higrometrem punktu rosy w generatorze wilgotnosci (20 do 30) °C od 5 % RH do 35 % RH CMC 0,6 % RH (20 do 30) °C od 35 % RH do 75 % RH CMC 0,8 % RH (20 do 30) °C od 75 % RH do 90 % RH CMC 1,0 % RH (20 do 30) °C od 90 % RH do 95 % RH CMC 1,5 % RH Relativni vlhkost / Cislicove vlhkomery Kalibrace – vlhkost vzduchu Porovnani s etalonovym rosnobodovym vlhkomerem v generatoru vlhkosti (20 az 30) °C 5 % RH az 35 % RH CMC 0,6 % RH (20 az 30) °C 35 % RH az 75 % RH CMC 0,8 % RH (20 az 30) °C 75 % RH az 90 % RH CMC 1,0 % RH (20 az 30) °C 90 % RH az 95 % RH CMC 1,5 % RH KP-04","search_en":"Relative air humidity / digital hygrometers Calibration – air humidity Comparison with a standard dew point hygrometer in a humidity generator CMC for the field of measured quantity: Air humidity Comparison with a standard dew point hygrometer in a humidity generator (20 to 30) °C (20 to 30) °C (20 to 30) °C (20 to 30) °C KP-04","search_zh":"相对湿度 / 数字湿度计 校准 – 空气湿度 在湿度发生器中与标准露点湿度计比较 被测量领域的CMC：空气湿度 在湿度发生器中与标准露点湿度计比较 (20 至 30) °C (20 至 30) °C (20 至 30) °C (20 至 30) °C KP-04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","methodology_de":"Kalibrierung – Luftfeuchte","parameters_de":[{"name":"(20 bis 30) °C","range":"von 5 % RH bis 35 % RH","cmc":"0,6 % RH"},{"name":"(20 bis 30) °C","range":"von 35 % RH bis 75 % RH","cmc":"0,8 % RH"},{"name":"(20 bis 30) °C","range":"von 75 % RH bis 90 % RH","cmc":"1,0 % RH"},{"name":"(20 bis 30) °C","range":"von 90 % RH bis 95 % RH","cmc":"1,5 % RH"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Luftfeuchte","search_de":"Relative Feuchte / Digitale Feuchtemessgeräte Kalibrierung – Luftfeuchte Vergleich mit Referenz-Taupunkthygrometer im Feuchtegenerator CMC für den Messgrößenbereich: Luftfeuchte Vergleich mit Referenz-Taupunkthygrometer im Feuchtegenerator (20 bis 30) °C (20 bis 30) °C (20 bis 30) °C (20 bis 30) °C KP-04","technique_de":"Vergleich mit Referenz-Taupunkthygrometer im Feuchtegenerator","techniques_de":["Vergleich mit Referenz-Taupunkthygrometer im Feuchtegenerator"],"test_object_de":"Relative Feuchte / Digitale Feuchtemessgeräte"}],"has_pdf":true}