🇨🇿 PEMIT, s.r.o. PL
Metrology & calibration
PEMIT, s.r.o. is a calibration laboratory accredited by ČIA under number 2337 (Paskov, Czech Republic). Its accreditation scope covers 14 calibration items in the following areas: Metrology & calibration. Calibrated items include: Direct-reading thermometers, Temperature sensors with transmitter, Deformation and electromechanical pressure gauges, Resistance temperature sensors. Most frequently used calibration principles: Comparison with a standard resistance sensor in a block furnace, Comparison with a standard resistance sensor in a liquid bath, Comparison with a type S thermocouple in a horizontal furnace.
At a glance
- Accreditation number: ČIA 2337
- Calibration items in scope: 14
- Types of calibrated items: 7
- Calibration principles used: 6
- City: Paskov, Czech Republic
- Valid until: 04-04-2030
- Accreditation number
- 2337
- Accreditation body
- ČIA
- Address
- Místecká 845, 739 21 Paskov
- City
- Paskov, Czech Republic
- Division
- Metrologia – laboratorium wzorcujące
- Valid until
- 04-04-2030
What this laboratory calibrates (7)
- Direct-reading thermometers — 3 calibration items
- Temperature sensors with transmitter — 3 calibration items
- Deformation and electromechanical pressure gauges — 2 calibration items
- Resistance temperature sensors — 2 calibration items
- Thermoelectric temperature sensors — 2 calibration items
- Calibration of output signals of resistance sensors — 1 calibration item
- Simulation of output signals of thermoelectric temperature sensors — 1 calibration item
Calibration principles (6)
- Comparison with a standard resistance sensor in a block furnace — 4 calibration items
- Comparison with a standard resistance sensor in a liquid bath — 3 calibration items
- Comparison with a type S thermocouple in a horizontal furnace — 3 calibration items
- Simulation with a Beamex MC5 multifunction calibrator — 2 calibration items
- Comparison with a Beamex MC5 digital pressure gauge — 1 calibration item
- Comparison with a Fluke PPC4 digital calibrator — 1 calibration item
Certificate information
- Certificate date
- 04.04.2025
Accreditation scope — calibration items (14)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Deformation and electromechanical pressure gauges | Calibration – pressure Gauge pressure; gas — -90 kPa to -67 kPa · CMC 3 Pa Gauge pressure; gas — -67 kPa to -15 kPa · CMC 9,2·10⁻⁵ Gauge pressure; gas — -15 kPa to 15 kPa · CMC 6,9·10⁻⁵ + 0,3 Pa Gauge pressure; gas — 15 kPa to 100 kPa · CMC 5,8·10⁻⁵ + 1,8 Pa Gauge pressure; gas — 100 kPa to 600 kPa · CMC 30 Pa Gauge pressure; gas — 600 kPa to 2 000 kPa · CMC 9,2·10⁻⁵ Absolute pressure; gas — 0 kPa to 33 kPa · CMC 1,7 Pa Absolute pressure; gas — 33 kPa to 110 kPa · CMC 9,2·10⁻⁵ Absolute pressure; gas — 110 kPa to 600 kPa · CMC 30 Pa Absolute pressure; gas — 600 kPa to 2 000 kPa · CMC 9,2·10⁻⁵ Absolute pressure; gas — 2 000 kPa to 10 000 kPa · CMC 5,0·10⁻⁴ + 1,5 kPa CMC for the field of measured quantity: Pressure |
Comparison with a Fluke PPC4 digital calibrator | P01, P02, P03 | |
| 2 | Deformation and electromechanical pressure gauges | Calibration – pressure 2 000 kPa to 10 000 kPa · CMC 5,0·10⁻⁴ + 1,5 kPa Gauge pressure, absolute pressure; water — 2 MPa to 16 MPa · CMC 3,5·10⁻⁴ + 2,1 kPa Gauge pressure, absolute pressure; water — 16 MPa to 25 MPa · CMC 3,5·10⁻⁴ + 4,5 kPa Gauge pressure, absolute pressure; water — 25 MPa to 60 MPa · CMC 3,5·10⁻⁴ + 9,5 kPa Barometric pressure — 80 kPa to 120 kPa · CMC 58 Pa CMC for the field of measured quantity: Pressure |
Comparison with a Beamex MC5 digital pressure gauge | P01, P02, P03 | |
| 3 | Resistance temperature sensors | Calibration – temperature 0 °C · CMC 0,06 °C -20 °C to 90 °C · CMC 0,07 °C 90 °C to 200 °C · CMC 0,09 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance sensor in a liquid bath | T01 | |
| 4 | Resistance temperature sensors | Calibration – temperature 200 °C to 400 °C · CMC 0,4 °C 400 °C to 600 °C · CMC 0,6 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance sensor in a block furnace | T01 | |
| 5 | Thermoelectric temperature sensors | Calibration – temperature -20 °C to 90 °C · CMC 0,5 °C 90 °C to 600 °C · CMC 0,6 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance sensor in a block furnace | T02 | |
| 6 | Thermoelectric temperature sensors | Calibration – temperature 600 °C to 1100 °C · CMC 1,6 °C CMC for the field of measured quantity: Temperature |
Comparison with a type S thermocouple in a horizontal furnace | T02 | |
| 7 | Direct-reading thermometers | Calibration – temperature -20 °C to 90 °C · CMC 0,07 °C 90 °C to 200 °C · CMC 0,09 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance sensor in a liquid bath | T04 | |
| 8 | Direct-reading thermometers | Calibration – temperature 200 °C to 400 °C · CMC 0,4 °C 400 °C to 600 °C · CMC 0,6 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance sensor in a block furnace | T04 | |
| 9 | Direct-reading thermometers | Calibration – temperature 600 °C to 1100 °C · CMC 1,6 °C CMC for the field of measured quantity: Temperature |
Comparison with a type S thermocouple in a horizontal furnace | T04 | |
| 10 | Temperature sensors with transmitter | Calibration – temperature -20 °C to 90 °C · CMC 0,07 °C 90 °C to 200 °C · CMC 0,09 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance sensor in a liquid bath | T05 | |
| 11 | Temperature sensors with transmitter | Calibration – temperature 200 °C to 400 °C · CMC 0,4 °C 400 °C to 600 °C · CMC 0,6 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance sensor in a block furnace | T05 | |
| 12 | Temperature sensors with transmitter | Calibration – temperature 600 °C to 1100 °C · CMC 1,6 °C CMC for the field of measured quantity: Temperature |
Comparison with a type S thermocouple in a horizontal furnace | T05 | |
| 13 | Simulation of output signals of thermoelectric temperature sensors | Calibration – temperature TC type B — 20 °C to 500 °C · CMC 2,1 °C TC type B — 500 °C to 1820 °C · CMC 0,9 °C TC type R — -50 °C to 150 °C · CMC 1,1 °C TC type R — 150 °C to 1768 °C · CMC 0,6 °C TC type S — -50 °C to 0 °C · CMC 1,1 °C TC type S — 0 °C to 1768 °C · CMC 0,8 °C TC type J — -200 °C to 0 °C · CMC 0,3 °C TC type J — 0 °C to 1200 °C · CMC 0,4 °C TC type K — -200 °C to 1000 °C · CMC 0,4 °C TC type K — 1000 °C to 1372 °C · CMC 0,5 °C TC type N — -200 °C to -100 °C · CMC 0,5 °C TC type N — -100 °C to 750 °C · CMC 0,4 °C TC type N — 750 °C to 1300 °C · CMC 0,5 °C CMC for the field of measured quantity: Temperature |
Simulation with a Beamex MC5 multifunction calibrator | R01 | |
| 14 | Calibration of output signals of resistance sensors | Calibration – temperature Pt 100, Pt 1000 — -200 °C to 0 °C · CMC 0,12 °C Pt 100, Pt 1000 — 0 °C to 850 °C · CMC 2,8·10⁻⁴ + 0,12 °C CMC for the field of measured quantity: Temperature |
Simulation with a Beamex MC5 multifunction calibrator | R01 | |
Reference standards (8)
P01
P02
P03
R01
T01
T02
T04
T05