{"lab":{"_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","address":"Místecká 845, 739 21 Paskov","categories":["metrology"],"city":"Paskov","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[18.2973862,49.7197388]},"map_coord":[49.7197388,18.2973862],"map_geo":"cai-mapa","methods_count":14,"name":"PEMIT, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów pomiarowych w dziedzinach: ciśnienie i temperatura.","search_text":"pemit, s.r.o. místecká 845, 739 21 paskov 2337","source_page_url":"https://www.cai.cz/?subjekt=2337-pemit-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"04-04-2030","website":"www.pemit.cz","certificate_date":"04.04.2025","certificate_no":"167/2025","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów pomiarowych w dziedzinach: ciśnienie i temperatura.","en":"Calibration of measuring instruments in the fields of pressure and temperature.","zh":"压力和温度领域测量仪器的校准。","cs":"Kalibrace měřidel v oboru tlak a teplota."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Metrologia – laboratorium wzorcujące","lab_division_cs":"Metrologie – kalibrační laboratoř","lab_division_en":"Metrology – Calibration Laboratory","lab_division_zh":"计量 – 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"a75a7116b34d63e83696aca86fa4354d23652dfb264c8f0ad6ea05486b378932","source_pdf_url":"https://www.cai.cz/OA/pdf/P167_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"9509343f3d8a2f05b79158f4","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i elektromechaniczne","test_object_en":"Deformation and electromechanical pressure gauges","test_object_zh":"弹性式和机电式压力表","test_object_cs":"Deformační a elektromechanické tlakoměry","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"Nadciśnienie; gaz","range":"od -90 kPa do -67 kPa","cmc":"3 Pa"},{"name":"Nadciśnienie; gaz","range":"od -67 kPa do -15 kPa","cmc":"9,2·10⁻⁵"},{"name":"Nadciśnienie; gaz","range":"od -15 kPa do 15 kPa","cmc":"6,9·10⁻⁵ + 0,3 Pa"},{"name":"Nadciśnienie; gaz","range":"od 15 kPa do 100 kPa","cmc":"5,8·10⁻⁵ + 1,8 Pa"},{"name":"Nadciśnienie; gaz","range":"od 100 kPa do 600 kPa","cmc":"30 Pa"},{"name":"Nadciśnienie; gaz","range":"od 600 kPa do 2 000 kPa","cmc":"9,2·10⁻⁵"},{"name":"Ciśnienie bezwzględne; gaz","range":"od 0 kPa do 33 kPa","cmc":"1,7 Pa"},{"name":"Ciśnienie bezwzględne; gaz","range":"od 33 kPa do 110 kPa","cmc":"9,2·10⁻⁵"},{"name":"Ciśnienie bezwzględne; gaz","range":"od 110 kPa do 600 kPa","cmc":"30 Pa"},{"name":"Ciśnienie bezwzględne; gaz","range":"od 600 kPa do 2 000 kPa","cmc":"9,2·10⁻⁵"},{"name":"Ciśnienie bezwzględne; gaz","range":"od 2 000 kPa do 10 000 kPa","cmc":"5,0·10⁻⁴ + 1,5 kPa"}],"parameters_en":[{"name":"Gauge pressure; gas","range":"-90 kPa to -67 kPa","cmc":"3 Pa"},{"name":"Gauge pressure; gas","range":"-67 kPa to -15 kPa","cmc":"9,2·10⁻⁵"},{"name":"Gauge pressure; gas","range":"-15 kPa to 15 kPa","cmc":"6,9·10⁻⁵ + 0,3 Pa"},{"name":"Gauge pressure; gas","range":"15 kPa to 100 kPa","cmc":"5,8·10⁻⁵ + 1,8 Pa"},{"name":"Gauge pressure; gas","range":"100 kPa to 600 kPa","cmc":"30 Pa"},{"name":"Gauge pressure; gas","range":"600 kPa to 2 000 kPa","cmc":"9,2·10⁻⁵"},{"name":"Absolute pressure; gas","range":"0 kPa to 33 kPa","cmc":"1,7 Pa"},{"name":"Absolute pressure; gas","range":"33 kPa to 110 kPa","cmc":"9,2·10⁻⁵"},{"name":"Absolute pressure; gas","range":"110 kPa to 600 kPa","cmc":"30 Pa"},{"name":"Absolute pressure; gas","range":"600 kPa to 2 000 kPa","cmc":"9,2·10⁻⁵"},{"name":"Absolute pressure; gas","range":"2 000 kPa to 10 000 kPa","cmc":"5,0·10⁻⁴ + 1,5 kPa"}],"parameters_zh":[{"name":"表压；气体","range":"-90 kPa 至 -67 kPa","cmc":"3 Pa"},{"name":"表压；气体","range":"-67 kPa 至 -15 kPa","cmc":"9,2·10⁻⁵"},{"name":"表压；气体","range":"-15 kPa 至 15 kPa","cmc":"6,9·10⁻⁵ + 0,3 Pa"},{"name":"表压；气体","range":"15 kPa 至 100 kPa","cmc":"5,8·10⁻⁵ + 1,8 Pa"},{"name":"表压；气体","range":"100 kPa 至 600 kPa","cmc":"30 Pa"},{"name":"表压；气体","range":"600 kPa 至 2 000 kPa","cmc":"9,2·10⁻⁵"},{"name":"绝对压力；气体","range":"0 kPa 至 33 kPa","cmc":"1,7 Pa"},{"name":"绝对压力；气体","range":"33 kPa 至 110 kPa","cmc":"9,2·10⁻⁵"},{"name":"绝对压力；气体","range":"110 kPa 至 600 kPa","cmc":"30 Pa"},{"name":"绝对压力；气体","range":"600 kPa 至 2 000 kPa","cmc":"9,2·10⁻⁵"},{"name":"绝对压力；气体","range":"2 000 kPa 至 10 000 kPa","cmc":"5,0·10⁻⁴ + 1,5 kPa"}],"parameters_cs":[{"name":"Přetlak; plyn","range":"-90 kPa až -67 kPa","cmc":"3 Pa"},{"name":"Přetlak; plyn","range":"-67 kPa až -15 kPa","cmc":"9,2·10⁻⁵"},{"name":"Přetlak; plyn","range":"-15 kPa až 15 kPa","cmc":"6,9·10⁻⁵ + 0,3 Pa"},{"name":"Přetlak; plyn","range":"15 kPa až 100 kPa","cmc":"5,8·10⁻⁵ + 1,8 Pa"},{"name":"Přetlak; plyn","range":"100 kPa až 600 kPa","cmc":"30 Pa"},{"name":"Přetlak; plyn","range":"600 kPa až 2 000 kPa","cmc":"9,2·10⁻⁵"},{"name":"Absolutní tlak; plyn","range":"0 kPa až 33 kPa","cmc":"1,7 Pa"},{"name":"Absolutní tlak; plyn","range":"33 kPa až 110 kPa","cmc":"9,2·10⁻⁵"},{"name":"Absolutní tlak; plyn","range":"110 kPa až 600 kPa","cmc":"30 Pa"},{"name":"Absolutní tlak; plyn","range":"600 kPa až 2 000 kPa","cmc":"9,2·10⁻⁵"},{"name":"Absolutní tlak; plyn","range":"2 000 kPa až 10 000 kPa","cmc":"5,0·10⁻⁴ + 1,5 kPa"}],"technique":"Porównanie z cyfrowym kalibratorem Fluke PPC4","technique_en":"Comparison with a Fluke PPC4 digital calibrator","technique_zh":"与 Fluke PPC4 数字校准器比较","technique_cs":"Porovnání s digitálním kalibrátorem Fluke PPC4","techniques":["Porównanie z cyfrowym kalibratorem Fluke PPC4"],"techniques_en":["Comparison with a Fluke PPC4 digital calibrator"],"techniques_zh":["与 Fluke PPC4 数字校准器比较"],"techniques_cs":["Porovnání s digitálním kalibrátorem Fluke PPC4"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nNadciśnienie; gaz od -90 kPa do -67 kPa CMC 3 Pa\nNadciśnienie; gaz od -67 kPa do -15 kPa CMC 9,2·10⁻⁵\nNadciśnienie; gaz od -15 kPa do 15 kPa CMC 6,9·10⁻⁵ + 0,3 Pa\nNadciśnienie; gaz od 15 kPa do 100 kPa CMC 5,8·10⁻⁵ + 1,8 Pa\nNadciśnienie; gaz od 100 kPa do 600 kPa CMC 30 Pa\nNadciśnienie; gaz od 600 kPa do 2 000 kPa CMC 9,2·10⁻⁵\nCiśnienie bezwzględne; gaz od 0 kPa do 33 kPa CMC 1,7 Pa\nCiśnienie bezwzględne; gaz od 33 kPa do 110 kPa CMC 9,2·10⁻⁵\nCiśnienie bezwzględne; gaz od 110 kPa do 600 kPa CMC 30 Pa\nCiśnienie bezwzględne; gaz od 600 kPa do 2 000 kPa CMC 9,2·10⁻⁵\nCiśnienie bezwzględne; gaz od 2 000 kPa do 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa\nPorównanie z cyfrowym kalibratorem Fluke PPC4","reference":"P01, P02, P03","norm_bases":["P01","P02","P03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i elektromechaniczne Wzorcowanie – ciśnienie Porównanie z cyfrowym kalibratorem Fluke PPC4 Nadciśnienie; gaz od -90 kPa do -67 kPa CMC 3 Pa Nadciśnienie; gaz od -67 kPa do -15 kPa CMC 9,2·10⁻⁵ Nadciśnienie; gaz od -15 kPa do 15 kPa CMC 6,9·10⁻⁵ + 0,3 Pa Nadciśnienie; gaz od 15 kPa do 100 kPa CMC 5,8·10⁻⁵ + 1,8 Pa Nadciśnienie; gaz od 100 kPa do 600 kPa CMC 30 Pa Nadciśnienie; gaz od 600 kPa do 2 000 kPa CMC 9,2·10⁻⁵ Ciśnienie bezwzględne; gaz od 0 kPa do 33 kPa CMC 1,7 Pa Ciśnienie bezwzględne; gaz od 33 kPa do 110 kPa CMC 9,2·10⁻⁵ Ciśnienie bezwzględne; gaz od 110 kPa do 600 kPa CMC 30 Pa Ciśnienie bezwzględne; gaz od 600 kPa do 2 000 kPa CMC 9,2·10⁻⁵ Ciśnienie bezwzględne; gaz od 2 000 kPa do 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa Deformační a elektromechanické tlakoměry Kalibrace – tlak Porovnání s digitálním kalibrátorem Fluke PPC4 Přetlak; plyn -90 kPa až -67 kPa CMC 3 Pa Přetlak; plyn -67 kPa až -15 kPa CMC 9,2·10⁻⁵ Přetlak; plyn -15 kPa až 15 kPa CMC 6,9·10⁻⁵ + 0,3 Pa Přetlak; plyn 15 kPa až 100 kPa CMC 5,8·10⁻⁵ + 1,8 Pa Přetlak; plyn 100 kPa až 600 kPa CMC 30 Pa Přetlak; plyn 600 kPa až 2 000 kPa CMC 9,2·10⁻⁵ Absolutní tlak; plyn 0 kPa až 33 kPa CMC 1,7 Pa Absolutní tlak; plyn 33 kPa až 110 kPa CMC 9,2·10⁻⁵ Absolutní tlak; plyn 110 kPa až 600 kPa CMC 30 Pa Absolutní tlak; plyn 600 kPa až 2 000 kPa CMC 9,2·10⁻⁵ Absolutní tlak; plyn 2 000 kPa až 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa P01, P02, P03 Cisnieniomierze sprezyste i elektromechaniczne Wzorcowanie – cisnienie Porownanie z cyfrowym kalibratorem Fluke PPC4 Nadcisnienie; gaz od -90 kPa do -67 kPa CMC 3 Pa Nadcisnienie; gaz od -67 kPa do -15 kPa CMC 9,2·10⁻⁵ Nadcisnienie; gaz od -15 kPa do 15 kPa CMC 6,9·10⁻⁵ + 0,3 Pa Nadcisnienie; gaz od 15 kPa do 100 kPa CMC 5,8·10⁻⁵ + 1,8 Pa Nadcisnienie; gaz od 100 kPa do 600 kPa CMC 30 Pa Nadcisnienie; gaz od 600 kPa do 2 000 kPa CMC 9,2·10⁻⁵ Cisnienie bezwzgledne; gaz od 0 kPa do 33 kPa CMC 1,7 Pa Cisnienie bezwzgledne; gaz od 33 kPa do 110 kPa CMC 9,2·10⁻⁵ Cisnienie bezwzgledne; gaz od 110 kPa do 600 kPa CMC 30 Pa Cisnienie bezwzgledne; gaz od 600 kPa do 2 000 kPa CMC 9,2·10⁻⁵ Cisnienie bezwzgledne; gaz od 2 000 kPa do 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa Deformacni a elektromechanicke tlakomery Kalibrace – tlak Porovnani s digitalnim kalibratorem Fluke PPC4 Pretlak; plyn -90 kPa az -67 kPa CMC 3 Pa Pretlak; plyn -67 kPa az -15 kPa CMC 9,2·10⁻⁵ Pretlak; plyn -15 kPa az 15 kPa CMC 6,9·10⁻⁵ + 0,3 Pa Pretlak; plyn 15 kPa az 100 kPa CMC 5,8·10⁻⁵ + 1,8 Pa Pretlak; plyn 100 kPa az 600 kPa CMC 30 Pa Pretlak; plyn 600 kPa az 2 000 kPa CMC 9,2·10⁻⁵ Absolutni tlak; plyn 0 kPa az 33 kPa CMC 1,7 Pa Absolutni tlak; plyn 33 kPa az 110 kPa CMC 9,2·10⁻⁵ Absolutni tlak; plyn 110 kPa az 600 kPa CMC 30 Pa Absolutni tlak; plyn 600 kPa az 2 000 kPa CMC 9,2·10⁻⁵ Absolutni tlak; plyn 2 000 kPa az 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa P01, P02, P03","search_en":"Deformation and electromechanical pressure gauges Calibration – pressure Comparison with a Fluke PPC4 digital calibrator Gauge pressure; gas -90 kPa to -67 kPa CMC 3 Pa Gauge pressure; gas -67 kPa to -15 kPa CMC 9,2·10⁻⁵ Gauge pressure; gas -15 kPa to 15 kPa CMC 6,9·10⁻⁵ + 0,3 Pa Gauge pressure; gas 15 kPa to 100 kPa CMC 5,8·10⁻⁵ + 1,8 Pa Gauge pressure; gas 100 kPa to 600 kPa CMC 30 Pa Gauge pressure; gas 600 kPa to 2 000 kPa CMC 9,2·10⁻⁵ Absolute pressure; gas 0 kPa to 33 kPa CMC 1,7 Pa Absolute pressure; gas 33 kPa to 110 kPa CMC 9,2·10⁻⁵ Absolute pressure; gas 110 kPa to 600 kPa CMC 30 Pa Absolute pressure; gas 600 kPa to 2 000 kPa CMC 9,2·10⁻⁵ Absolute pressure; gas 2 000 kPa to 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa P01, P02, P03","search_zh":"弹性式和机电式压力表 校准 – 压力 与 Fluke PPC4 数字校准器比较 表压；气体 -90 kPa 至 -67 kPa CMC 3 Pa 表压；气体 -67 kPa 至 -15 kPa CMC 9,2·10⁻⁵ 表压；气体 -15 kPa 至 15 kPa CMC 6,9·10⁻⁵ + 0,3 Pa 表压；气体 15 kPa 至 100 kPa CMC 5,8·10⁻⁵ + 1,8 Pa 表压；气体 100 kPa 至 600 kPa CMC 30 Pa 表压；气体 600 kPa 至 2 000 kPa CMC 9,2·10⁻⁵ 绝对压力；气体 0 kPa 至 33 kPa CMC 1,7 Pa 绝对压力；气体 33 kPa 至 110 kPa CMC 9,2·10⁻⁵ 绝对压力；气体 110 kPa 至 600 kPa CMC 30 Pa 绝对压力；气体 600 kPa 至 2 000 kPa CMC 9,2·10⁻⁵ 绝对压力；气体 2 000 kPa 至 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa P01, P02, P03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"977744630aba9de883ff358a","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i elektromechaniczne","test_object_en":"Deformation and electromechanical pressure gauges","test_object_zh":"弹性式和机电式压力表","test_object_cs":"Deformační a elektromechanické tlakoměry","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"","range":"od 2 000 kPa do 10 000 kPa","cmc":"5,0·10⁻⁴ + 1,5 kPa"},{"name":"Nadciśnienie, ciśnienie bezwzględne; woda","range":"od 2 MPa do 16 MPa","cmc":"3,5·10⁻⁴ + 2,1 kPa"},{"name":"Nadciśnienie, ciśnienie bezwzględne; woda","range":"od 16 MPa do 25 MPa","cmc":"3,5·10⁻⁴ + 4,5 kPa"},{"name":"Nadciśnienie, ciśnienie bezwzględne; woda","range":"od 25 MPa do 60 MPa","cmc":"3,5·10⁻⁴ + 9,5 kPa"},{"name":"Ciśnienie barometryczne","range":"od 80 kPa do 120 kPa","cmc":"58 Pa"}],"parameters_en":[{"name":"","range":"2 000 kPa to 10 000 kPa","cmc":"5,0·10⁻⁴ + 1,5 kPa"},{"name":"Gauge pressure, absolute pressure; water","range":"2 MPa to 16 MPa","cmc":"3,5·10⁻⁴ + 2,1 kPa"},{"name":"Gauge pressure, absolute pressure; water","range":"16 MPa to 25 MPa","cmc":"3,5·10⁻⁴ + 4,5 kPa"},{"name":"Gauge pressure, absolute pressure; water","range":"25 MPa to 60 MPa","cmc":"3,5·10⁻⁴ + 9,5 kPa"},{"name":"Barometric pressure","range":"80 kPa to 120 kPa","cmc":"58 Pa"}],"parameters_zh":[{"name":"","range":"2 000 kPa 至 10 000 kPa","cmc":"5,0·10⁻⁴ + 1,5 kPa"},{"name":"表压、绝对压力；水","range":"2 MPa 至 16 MPa","cmc":"3,5·10⁻⁴ + 2,1 kPa"},{"name":"表压、绝对压力；水","range":"16 MPa 至 25 MPa","cmc":"3,5·10⁻⁴ + 4,5 kPa"},{"name":"表压、绝对压力；水","range":"25 MPa 至 60 MPa","cmc":"3,5·10⁻⁴ + 9,5 kPa"},{"name":"大气压力","range":"80 kPa 至 120 kPa","cmc":"58 Pa"}],"parameters_cs":[{"name":"","range":"2 000 kPa až 10 000 kPa","cmc":"5,0·10⁻⁴ + 1,5 kPa"},{"name":"Přetlak, absolutní tlak; voda","range":"2 MPa až 16 MPa","cmc":"3,5·10⁻⁴ + 2,1 kPa"},{"name":"Přetlak, absolutní tlak; voda","range":"16 MPa až 25 MPa","cmc":"3,5·10⁻⁴ + 4,5 kPa"},{"name":"Přetlak, absolutní tlak; voda","range":"25 MPa až 60 MPa","cmc":"3,5·10⁻⁴ + 9,5 kPa"},{"name":"Barometrický tlak","range":"80 kPa až 120 kPa","cmc":"58 Pa"}],"technique":"Porównanie z cyfrowym ciśnieniomierzem Beamex MC5","technique_en":"Comparison with a Beamex MC5 digital pressure gauge","technique_zh":"与 Beamex MC5 数字压力表比较","technique_cs":"Porovnání s digitálním tlakoměrem Beamex MC5","techniques":["Porównanie z cyfrowym ciśnieniomierzem Beamex MC5"],"techniques_en":["Comparison with a Beamex MC5 digital pressure gauge"],"techniques_zh":["与 Beamex MC5 数字压力表比较"],"techniques_cs":["Porovnání s digitálním tlakoměrem Beamex MC5"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nod 2 000 kPa do 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa\nNadciśnienie, ciśnienie bezwzględne; woda od 2 MPa do 16 MPa CMC 3,5·10⁻⁴ + 2,1 kPa\nNadciśnienie, ciśnienie bezwzględne; woda od 16 MPa do 25 MPa CMC 3,5·10⁻⁴ + 4,5 kPa\nNadciśnienie, ciśnienie bezwzględne; woda od 25 MPa do 60 MPa CMC 3,5·10⁻⁴ + 9,5 kPa\nCiśnienie barometryczne od 80 kPa do 120 kPa CMC 58 Pa\nPorównanie z cyfrowym ciśnieniomierzem Beamex MC5","reference":"P01, P02, P03","norm_bases":["P01","P02","P03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i elektromechaniczne Wzorcowanie – ciśnienie Porównanie z cyfrowym ciśnieniomierzem Beamex MC5 od 2 000 kPa do 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa Nadciśnienie, ciśnienie bezwzględne; woda od 2 MPa do 16 MPa CMC 3,5·10⁻⁴ + 2,1 kPa Nadciśnienie, ciśnienie bezwzględne; woda od 16 MPa do 25 MPa CMC 3,5·10⁻⁴ + 4,5 kPa Nadciśnienie, ciśnienie bezwzględne; woda od 25 MPa do 60 MPa CMC 3,5·10⁻⁴ + 9,5 kPa Ciśnienie barometryczne od 80 kPa do 120 kPa CMC 58 Pa Deformační a elektromechanické tlakoměry Kalibrace – tlak Porovnání s digitálním tlakoměrem Beamex MC5 2 000 kPa až 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa Přetlak, absolutní tlak; voda 2 MPa až 16 MPa CMC 3,5·10⁻⁴ + 2,1 kPa Přetlak, absolutní tlak; voda 16 MPa až 25 MPa CMC 3,5·10⁻⁴ + 4,5 kPa Přetlak, absolutní tlak; voda 25 MPa až 60 MPa CMC 3,5·10⁻⁴ + 9,5 kPa Barometrický tlak 80 kPa až 120 kPa CMC 58 Pa P01, P02, P03 Cisnieniomierze sprezyste i elektromechaniczne Wzorcowanie – cisnienie Porownanie z cyfrowym cisnieniomierzem Beamex MC5 od 2 000 kPa do 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa Nadcisnienie, cisnienie bezwzgledne; woda od 2 MPa do 16 MPa CMC 3,5·10⁻⁴ + 2,1 kPa Nadcisnienie, cisnienie bezwzgledne; woda od 16 MPa do 25 MPa CMC 3,5·10⁻⁴ + 4,5 kPa Nadcisnienie, cisnienie bezwzgledne; woda od 25 MPa do 60 MPa CMC 3,5·10⁻⁴ + 9,5 kPa Cisnienie barometryczne od 80 kPa do 120 kPa CMC 58 Pa Deformacni a elektromechanicke tlakomery Kalibrace – tlak Porovnani s digitalnim tlakomerem Beamex MC5 2 000 kPa az 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa Pretlak, absolutni tlak; voda 2 MPa az 16 MPa CMC 3,5·10⁻⁴ + 2,1 kPa Pretlak, absolutni tlak; voda 16 MPa az 25 MPa CMC 3,5·10⁻⁴ + 4,5 kPa Pretlak, absolutni tlak; voda 25 MPa az 60 MPa CMC 3,5·10⁻⁴ + 9,5 kPa Barometricky tlak 80 kPa az 120 kPa CMC 58 Pa P01, P02, P03","search_en":"Deformation and electromechanical pressure gauges Calibration – pressure Comparison with a Beamex MC5 digital pressure gauge 2 000 kPa to 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa Gauge pressure, absolute pressure; water 2 MPa to 16 MPa CMC 3,5·10⁻⁴ + 2,1 kPa Gauge pressure, absolute pressure; water 16 MPa to 25 MPa CMC 3,5·10⁻⁴ + 4,5 kPa Gauge pressure, absolute pressure; water 25 MPa to 60 MPa CMC 3,5·10⁻⁴ + 9,5 kPa Barometric pressure 80 kPa to 120 kPa CMC 58 Pa P01, P02, P03","search_zh":"弹性式和机电式压力表 校准 – 压力 与 Beamex MC5 数字压力表比较 2 000 kPa 至 10 000 kPa CMC 5,0·10⁻⁴ + 1,5 kPa 表压、绝对压力；水 2 MPa 至 16 MPa CMC 3,5·10⁻⁴ + 2,1 kPa 表压、绝对压力；水 16 MPa 至 25 MPa CMC 3,5·10⁻⁴ + 4,5 kPa 表压、绝对压力；水 25 MPa 至 60 MPa CMC 3,5·10⁻⁴ + 9,5 kPa 大气压力 80 kPa 至 120 kPa CMC 58 Pa P01, P02, P03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ce6eb43ced617322372a26cf","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"1","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0 °C","cmc":"0,06 °C"},{"name":"","range":"od -20 °C do 90 °C","cmc":"0,07 °C"},{"name":"","range":"od 90 °C do 200 °C","cmc":"0,09 °C"}],"parameters_en":[{"name":"","range":"0 °C","cmc":"0,06 °C"},{"name":"","range":"-20 °C to 90 °C","cmc":"0,07 °C"},{"name":"","range":"90 °C to 200 °C","cmc":"0,09 °C"}],"parameters_zh":[{"name":"","range":"0 °C","cmc":"0,06 °C"},{"name":"","range":"-20 °C 至 90 °C","cmc":"0,07 °C"},{"name":"","range":"90 °C 至 200 °C","cmc":"0,09 °C"}],"parameters_cs":[{"name":"","range":"0 °C","cmc":"0,06 °C"},{"name":"","range":"-20 °C až 90 °C","cmc":"0,07 °C"},{"name":"","range":"90 °C až 200 °C","cmc":"0,09 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a standard resistance sensor in a liquid bath","technique_zh":"在液体槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kapalinové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a standard resistance sensor in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\n0 °C CMC 0,06 °C\nod -20 °C do 90 °C CMC 0,07 °C\nod 90 °C do 200 °C CMC 0,09 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","reference":"T01","norm_bases":["T01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej 0 °C CMC 0,06 °C od -20 °C do 90 °C CMC 0,07 °C od 90 °C do 200 °C CMC 0,09 °C Odporové snímače teploty Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kapalinové lázni 0 °C CMC 0,06 °C -20 °C až 90 °C CMC 0,07 °C 90 °C až 200 °C CMC 0,09 °C T01 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni cieczowej 0 °C CMC 0,06 °C od -20 °C do 90 °C CMC 0,07 °C od 90 °C do 200 °C CMC 0,09 °C Odporove snimace teploty Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kapalinove lazni 0 °C CMC 0,06 °C -20 °C az 90 °C CMC 0,07 °C 90 °C az 200 °C CMC 0,09 °C T01","search_en":"Resistance temperature sensors Calibration – temperature Comparison with a standard resistance sensor in a liquid bath 0 °C CMC 0,06 °C -20 °C to 90 °C CMC 0,07 °C 90 °C to 200 °C CMC 0,09 °C T01","search_zh":"电阻温度传感器 校准 – 温度 在液体槽中与标准电阻传感器比较 0 °C CMC 0,06 °C -20 °C 至 90 °C CMC 0,07 °C 90 °C 至 200 °C CMC 0,09 °C T01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a201630aa97ae966f9eb5fcd","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"1","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 200 °C do 400 °C","cmc":"0,4 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"0,6 °C"}],"parameters_en":[{"name":"","range":"200 °C to 400 °C","cmc":"0,4 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"0,6 °C"}],"parameters_zh":[{"name":"","range":"200 °C 至 400 °C","cmc":"0,4 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"0,6 °C"}],"parameters_cs":[{"name":"","range":"200 °C až 400 °C","cmc":"0,4 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"0,6 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym","technique_en":"Comparison with a standard resistance sensor in a block furnace","technique_zh":"在块式炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v blokové peci","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym"],"techniques_en":["Comparison with a standard resistance sensor in a block furnace"],"techniques_zh":["在块式炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v blokové peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 200 °C do 400 °C CMC 0,4 °C\nod 400 °C do 600 °C CMC 0,6 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym","reference":"T01","norm_bases":["T01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym od 200 °C do 400 °C CMC 0,4 °C od 400 °C do 600 °C CMC 0,6 °C Odporové snímače teploty Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v blokové peci 200 °C až 400 °C CMC 0,4 °C 400 °C až 600 °C CMC 0,6 °C T01 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym od 200 °C do 400 °C CMC 0,4 °C od 400 °C do 600 °C CMC 0,6 °C Odporove snimace teploty Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v blokove peci 200 °C az 400 °C CMC 0,4 °C 400 °C az 600 °C CMC 0,6 °C T01","search_en":"Resistance temperature sensors Calibration – temperature Comparison with a standard resistance sensor in a block furnace 200 °C to 400 °C CMC 0,4 °C 400 °C to 600 °C CMC 0,6 °C T01","search_zh":"电阻温度传感器 校准 – 温度 在块式炉中与标准电阻传感器比较 200 °C 至 400 °C CMC 0,4 °C 400 °C 至 600 °C CMC 0,6 °C T01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43441a1f5408387dfb588299","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermoelectric temperature sensors","test_object_zh":"热电温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -20 °C do 90 °C","cmc":"0,5 °C"},{"name":"","range":"od 90 °C do 600 °C","cmc":"0,6 °C"}],"parameters_en":[{"name":"","range":"-20 °C to 90 °C","cmc":"0,5 °C"},{"name":"","range":"90 °C to 600 °C","cmc":"0,6 °C"}],"parameters_zh":[{"name":"","range":"-20 °C 至 90 °C","cmc":"0,5 °C"},{"name":"","range":"90 °C 至 600 °C","cmc":"0,6 °C"}],"parameters_cs":[{"name":"","range":"-20 °C až 90 °C","cmc":"0,5 °C"},{"name":"","range":"90 °C až 600 °C","cmc":"0,6 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym","technique_en":"Comparison with a standard resistance sensor in a block furnace","technique_zh":"在块式炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v blokové peci","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym"],"techniques_en":["Comparison with a standard resistance sensor in a block furnace"],"techniques_zh":["在块式炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v blokové peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -20 °C do 90 °C CMC 0,5 °C\nod 90 °C do 600 °C CMC 0,6 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym","reference":"T02","norm_bases":["T02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym od -20 °C do 90 °C CMC 0,5 °C od 90 °C do 600 °C CMC 0,6 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v blokové peci -20 °C až 90 °C CMC 0,5 °C 90 °C až 600 °C CMC 0,6 °C T02 Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym od -20 °C do 90 °C CMC 0,5 °C od 90 °C do 600 °C CMC 0,6 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v blokove peci -20 °C az 90 °C CMC 0,5 °C 90 °C az 600 °C CMC 0,6 °C T02","search_en":"Thermoelectric temperature sensors Calibration – temperature Comparison with a standard resistance sensor in a block furnace -20 °C to 90 °C CMC 0,5 °C 90 °C to 600 °C CMC 0,6 °C T02","search_zh":"热电温度传感器 校准 – 温度 在块式炉中与标准电阻传感器比较 -20 °C 至 90 °C CMC 0,5 °C 90 °C 至 600 °C CMC 0,6 °C T02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8b3a3fc29416ba8053a537dd","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermoelectric temperature sensors","test_object_zh":"热电温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 600 °C do 1100 °C","cmc":"1,6 °C"}],"parameters_en":[{"name":"","range":"600 °C to 1100 °C","cmc":"1,6 °C"}],"parameters_zh":[{"name":"","range":"600 °C 至 1100 °C","cmc":"1,6 °C"}],"parameters_cs":[{"name":"","range":"600 °C až 1100 °C","cmc":"1,6 °C"}],"technique":"Porównanie z termoparą typu S w piecu poziomym","technique_en":"Comparison with a type S thermocouple in a horizontal furnace","technique_zh":"在卧式炉中与 S 型热电偶比较","technique_cs":"Porovnání s TC typu S v horizontální peci","techniques":["Porównanie z termoparą typu S w piecu poziomym"],"techniques_en":["Comparison with a type S thermocouple in a horizontal furnace"],"techniques_zh":["在卧式炉中与 S 型热电偶比较"],"techniques_cs":["Porovnání s TC typu S v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 600 °C do 1100 °C CMC 1,6 °C\nPorównanie z termoparą typu S w piecu poziomym","reference":"T02","norm_bases":["T02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z termoparą typu S w piecu poziomym od 600 °C do 1100 °C CMC 1,6 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s TC typu S v horizontální peci 600 °C až 1100 °C CMC 1,6 °C T02 Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z termopara typu S w piecu poziomym od 600 °C do 1100 °C CMC 1,6 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s TC typu S v horizontalni peci 600 °C az 1100 °C CMC 1,6 °C T02","search_en":"Thermoelectric temperature sensors Calibration – temperature Comparison with a type S thermocouple in a horizontal furnace 600 °C to 1100 °C CMC 1,6 °C T02","search_zh":"热电温度传感器 校准 – 温度 在卧式炉中与 S 型热电偶比较 600 °C 至 1100 °C CMC 1,6 °C T02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"196ba06ef49b8951b49d6eef","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"3","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-reading thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -20 °C do 90 °C","cmc":"0,07 °C"},{"name":"","range":"od 90 °C do 200 °C","cmc":"0,09 °C"}],"parameters_en":[{"name":"","range":"-20 °C to 90 °C","cmc":"0,07 °C"},{"name":"","range":"90 °C to 200 °C","cmc":"0,09 °C"}],"parameters_zh":[{"name":"","range":"-20 °C 至 90 °C","cmc":"0,07 °C"},{"name":"","range":"90 °C 至 200 °C","cmc":"0,09 °C"}],"parameters_cs":[{"name":"","range":"-20 °C až 90 °C","cmc":"0,07 °C"},{"name":"","range":"90 °C až 200 °C","cmc":"0,09 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a standard resistance sensor in a liquid bath","technique_zh":"在液体槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kapalinové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a standard resistance sensor in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -20 °C do 90 °C CMC 0,07 °C\nod 90 °C do 200 °C CMC 0,09 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","reference":"T04","norm_bases":["T04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej od -20 °C do 90 °C CMC 0,07 °C od 90 °C do 200 °C CMC 0,09 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kapalinové lázni -20 °C až 90 °C CMC 0,07 °C 90 °C až 200 °C CMC 0,09 °C T04 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni cieczowej od -20 °C do 90 °C CMC 0,07 °C od 90 °C do 200 °C CMC 0,09 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kapalinove lazni -20 °C az 90 °C CMC 0,07 °C 90 °C az 200 °C CMC 0,09 °C T04","search_en":"Direct-reading thermometers Calibration – temperature Comparison with a standard resistance sensor in a liquid bath -20 °C to 90 °C CMC 0,07 °C 90 °C to 200 °C CMC 0,09 °C T04","search_zh":"直读式温度计 校准 – 温度 在液体槽中与标准电阻传感器比较 -20 °C 至 90 °C CMC 0,07 °C 90 °C 至 200 °C CMC 0,09 °C T04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"32d28c718115366886cda5bc","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"3","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-reading thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 200 °C do 400 °C","cmc":"0,4 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"0,6 °C"}],"parameters_en":[{"name":"","range":"200 °C to 400 °C","cmc":"0,4 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"0,6 °C"}],"parameters_zh":[{"name":"","range":"200 °C 至 400 °C","cmc":"0,4 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"0,6 °C"}],"parameters_cs":[{"name":"","range":"200 °C až 400 °C","cmc":"0,4 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"0,6 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym","technique_en":"Comparison with a standard resistance sensor in a block furnace","technique_zh":"在块式炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v blokové peci","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym"],"techniques_en":["Comparison with a standard resistance sensor in a block furnace"],"techniques_zh":["在块式炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v blokové peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 200 °C do 400 °C CMC 0,4 °C\nod 400 °C do 600 °C CMC 0,6 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym","reference":"T04","norm_bases":["T04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym od 200 °C do 400 °C CMC 0,4 °C od 400 °C do 600 °C CMC 0,6 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v blokové peci 200 °C až 400 °C CMC 0,4 °C 400 °C až 600 °C CMC 0,6 °C T04 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym od 200 °C do 400 °C CMC 0,4 °C od 400 °C do 600 °C CMC 0,6 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v blokove peci 200 °C az 400 °C CMC 0,4 °C 400 °C az 600 °C CMC 0,6 °C T04","search_en":"Direct-reading thermometers Calibration – temperature Comparison with a standard resistance sensor in a block furnace 200 °C to 400 °C CMC 0,4 °C 400 °C to 600 °C CMC 0,6 °C T04","search_zh":"直读式温度计 校准 – 温度 在块式炉中与标准电阻传感器比较 200 °C 至 400 °C CMC 0,4 °C 400 °C 至 600 °C CMC 0,6 °C T04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca3eddaf4b8bb6edd9de7a87","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"3","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-reading thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 600 °C do 1100 °C","cmc":"1,6 °C"}],"parameters_en":[{"name":"","range":"600 °C to 1100 °C","cmc":"1,6 °C"}],"parameters_zh":[{"name":"","range":"600 °C 至 1100 °C","cmc":"1,6 °C"}],"parameters_cs":[{"name":"","range":"600 °C až 1100 °C","cmc":"1,6 °C"}],"technique":"Porównanie z termoparą typu S w piecu poziomym","technique_en":"Comparison with a type S thermocouple in a horizontal furnace","technique_zh":"在卧式炉中与 S 型热电偶比较","technique_cs":"Porovnání s TC typu S v horizontální peci","techniques":["Porównanie z termoparą typu S w piecu poziomym"],"techniques_en":["Comparison with a type S thermocouple in a horizontal furnace"],"techniques_zh":["在卧式炉中与 S 型热电偶比较"],"techniques_cs":["Porovnání s TC typu S v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 600 °C do 1100 °C CMC 1,6 °C\nPorównanie z termoparą typu S w piecu poziomym","reference":"T04","norm_bases":["T04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z termoparą typu S w piecu poziomym od 600 °C do 1100 °C CMC 1,6 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s TC typu S v horizontální peci 600 °C až 1100 °C CMC 1,6 °C T04 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z termopara typu S w piecu poziomym od 600 °C do 1100 °C CMC 1,6 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s TC typu S v horizontalni peci 600 °C az 1100 °C CMC 1,6 °C T04","search_en":"Direct-reading thermometers Calibration – temperature Comparison with a type S thermocouple in a horizontal furnace 600 °C to 1100 °C CMC 1,6 °C T04","search_zh":"直读式温度计 校准 – 温度 在卧式炉中与 S 型热电偶比较 600 °C 至 1100 °C CMC 1,6 °C T04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b844ec9603e5c8fcee1f1fe6","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"4","test_object":"Czujniki temperatury z przetwornikiem","test_object_en":"Temperature sensors with transmitter","test_object_zh":"带变送器的温度传感器","test_object_cs":"Snímače teploty s převodníkem","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -20 °C do 90 °C","cmc":"0,07 °C"},{"name":"","range":"od 90 °C do 200 °C","cmc":"0,09 °C"}],"parameters_en":[{"name":"","range":"-20 °C to 90 °C","cmc":"0,07 °C"},{"name":"","range":"90 °C to 200 °C","cmc":"0,09 °C"}],"parameters_zh":[{"name":"","range":"-20 °C 至 90 °C","cmc":"0,07 °C"},{"name":"","range":"90 °C 至 200 °C","cmc":"0,09 °C"}],"parameters_cs":[{"name":"","range":"-20 °C až 90 °C","cmc":"0,07 °C"},{"name":"","range":"90 °C až 200 °C","cmc":"0,09 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a standard resistance sensor in a liquid bath","technique_zh":"在液体槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kapalinové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a standard resistance sensor in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -20 °C do 90 °C CMC 0,07 °C\nod 90 °C do 200 °C CMC 0,09 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","reference":"T05","norm_bases":["T05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej od -20 °C do 90 °C CMC 0,07 °C od 90 °C do 200 °C CMC 0,09 °C Snímače teploty s převodníkem Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kapalinové lázni -20 °C až 90 °C CMC 0,07 °C 90 °C až 200 °C CMC 0,09 °C T05 Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni cieczowej od -20 °C do 90 °C CMC 0,07 °C od 90 °C do 200 °C CMC 0,09 °C Snimace teploty s prevodnikem Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kapalinove lazni -20 °C az 90 °C CMC 0,07 °C 90 °C az 200 °C CMC 0,09 °C T05","search_en":"Temperature sensors with transmitter Calibration – temperature Comparison with a standard resistance sensor in a liquid bath -20 °C to 90 °C CMC 0,07 °C 90 °C to 200 °C CMC 0,09 °C T05","search_zh":"带变送器的温度传感器 校准 – 温度 在液体槽中与标准电阻传感器比较 -20 °C 至 90 °C CMC 0,07 °C 90 °C 至 200 °C CMC 0,09 °C T05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25ea2f42c70fd9deffe1183a","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"4","test_object":"Czujniki temperatury z przetwornikiem","test_object_en":"Temperature sensors with transmitter","test_object_zh":"带变送器的温度传感器","test_object_cs":"Snímače teploty s převodníkem","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 200 °C do 400 °C","cmc":"0,4 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"0,6 °C"}],"parameters_en":[{"name":"","range":"200 °C to 400 °C","cmc":"0,4 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"0,6 °C"}],"parameters_zh":[{"name":"","range":"200 °C 至 400 °C","cmc":"0,4 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"0,6 °C"}],"parameters_cs":[{"name":"","range":"200 °C až 400 °C","cmc":"0,4 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"0,6 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym","technique_en":"Comparison with a standard resistance sensor in a block furnace","technique_zh":"在块式炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v blokové peci","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym"],"techniques_en":["Comparison with a standard resistance sensor in a block furnace"],"techniques_zh":["在块式炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v blokové peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 200 °C do 400 °C CMC 0,4 °C\nod 400 °C do 600 °C CMC 0,6 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym","reference":"T05","norm_bases":["T05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym od 200 °C do 400 °C CMC 0,4 °C od 400 °C do 600 °C CMC 0,6 °C Snímače teploty s převodníkem Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v blokové peci 200 °C až 400 °C CMC 0,4 °C 400 °C až 600 °C CMC 0,6 °C T05 Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu blokowym od 200 °C do 400 °C CMC 0,4 °C od 400 °C do 600 °C CMC 0,6 °C Snimace teploty s prevodnikem Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v blokove peci 200 °C az 400 °C CMC 0,4 °C 400 °C az 600 °C CMC 0,6 °C T05","search_en":"Temperature sensors with transmitter Calibration – temperature Comparison with a standard resistance sensor in a block furnace 200 °C to 400 °C CMC 0,4 °C 400 °C to 600 °C CMC 0,6 °C T05","search_zh":"带变送器的温度传感器 校准 – 温度 在块式炉中与标准电阻传感器比较 200 °C 至 400 °C CMC 0,4 °C 400 °C 至 600 °C CMC 0,6 °C T05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6c6d4e2cfdca3b631fadeb64","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"4","test_object":"Czujniki temperatury z przetwornikiem","test_object_en":"Temperature sensors with transmitter","test_object_zh":"带变送器的温度传感器","test_object_cs":"Snímače teploty s převodníkem","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 600 °C do 1100 °C","cmc":"1,6 °C"}],"parameters_en":[{"name":"","range":"600 °C to 1100 °C","cmc":"1,6 °C"}],"parameters_zh":[{"name":"","range":"600 °C 至 1100 °C","cmc":"1,6 °C"}],"parameters_cs":[{"name":"","range":"600 °C až 1100 °C","cmc":"1,6 °C"}],"technique":"Porównanie z termoparą typu S w piecu poziomym","technique_en":"Comparison with a type S thermocouple in a horizontal furnace","technique_zh":"在卧式炉中与 S 型热电偶比较","technique_cs":"Porovnání s TC typu S v horizontální peci","techniques":["Porównanie z termoparą typu S w piecu poziomym"],"techniques_en":["Comparison with a type S thermocouple in a horizontal furnace"],"techniques_zh":["在卧式炉中与 S 型热电偶比较"],"techniques_cs":["Porovnání s TC typu S v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 600 °C do 1100 °C CMC 1,6 °C\nPorównanie z termoparą typu S w piecu poziomym","reference":"T05","norm_bases":["T05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porównanie z termoparą typu S w piecu poziomym od 600 °C do 1100 °C CMC 1,6 °C Snímače teploty s převodníkem Kalibrace – teplota Porovnání s TC typu S v horizontální peci 600 °C až 1100 °C CMC 1,6 °C T05 Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porownanie z termopara typu S w piecu poziomym od 600 °C do 1100 °C CMC 1,6 °C Snimace teploty s prevodnikem Kalibrace – teplota Porovnani s TC typu S v horizontalni peci 600 °C az 1100 °C CMC 1,6 °C T05","search_en":"Temperature sensors with transmitter Calibration – temperature Comparison with a type S thermocouple in a horizontal furnace 600 °C to 1100 °C CMC 1,6 °C T05","search_zh":"带变送器的温度传感器 校准 – 温度 在卧式炉中与 S 型热电偶比较 600 °C 至 1100 °C CMC 1,6 °C T05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ef9acc059ef062c0aa42d92e","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"5","test_object":"Symulacja sygnałów wyjściowych termoelektrycznych czujników temperatury","test_object_en":"Simulation of output signals of thermoelectric temperature sensors","test_object_zh":"热电温度传感器输出信号的模拟","test_object_cs":"Simulace výstupních signálů termoelektrických snímačů teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"TC typu B","range":"od 20 °C do 500 °C","cmc":"2,1 °C"},{"name":"TC typu B","range":"od 500 °C do 1820 °C","cmc":"0,9 °C"},{"name":"TC typu R","range":"od -50 °C do 150 °C","cmc":"1,1 °C"},{"name":"TC typu R","range":"od 150 °C do 1768 °C","cmc":"0,6 °C"},{"name":"TC typu S","range":"od -50 °C do 0 °C","cmc":"1,1 °C"},{"name":"TC typu S","range":"od 0 °C do 1768 °C","cmc":"0,8 °C"},{"name":"TC typu J","range":"od -200 °C do 0 °C","cmc":"0,3 °C"},{"name":"TC typu J","range":"od 0 °C do 1200 °C","cmc":"0,4 °C"},{"name":"TC typu K","range":"od -200 °C do 1000 °C","cmc":"0,4 °C"},{"name":"TC typu K","range":"od 1000 °C do 1372 °C","cmc":"0,5 °C"},{"name":"TC typu N","range":"od -200 °C do -100 °C","cmc":"0,5 °C"},{"name":"TC typu N","range":"od -100 °C do 750 °C","cmc":"0,4 °C"},{"name":"TC typu N","range":"od 750 °C do 1300 °C","cmc":"0,5 °C"}],"parameters_en":[{"name":"TC type B","range":"20 °C to 500 °C","cmc":"2,1 °C"},{"name":"TC type B","range":"500 °C to 1820 °C","cmc":"0,9 °C"},{"name":"TC type R","range":"-50 °C to 150 °C","cmc":"1,1 °C"},{"name":"TC type R","range":"150 °C to 1768 °C","cmc":"0,6 °C"},{"name":"TC type S","range":"-50 °C to 0 °C","cmc":"1,1 °C"},{"name":"TC type S","range":"0 °C to 1768 °C","cmc":"0,8 °C"},{"name":"TC type J","range":"-200 °C to 0 °C","cmc":"0,3 °C"},{"name":"TC type J","range":"0 °C to 1200 °C","cmc":"0,4 °C"},{"name":"TC type K","range":"-200 °C to 1000 °C","cmc":"0,4 °C"},{"name":"TC type K","range":"1000 °C to 1372 °C","cmc":"0,5 °C"},{"name":"TC type N","range":"-200 °C to -100 °C","cmc":"0,5 °C"},{"name":"TC type N","range":"-100 °C to 750 °C","cmc":"0,4 °C"},{"name":"TC type N","range":"750 °C to 1300 °C","cmc":"0,5 °C"}],"parameters_zh":[{"name":"B 型热电偶","range":"20 °C 至 500 °C","cmc":"2,1 °C"},{"name":"B 型热电偶","range":"500 °C 至 1820 °C","cmc":"0,9 °C"},{"name":"R 型热电偶","range":"-50 °C 至 150 °C","cmc":"1,1 °C"},{"name":"R 型热电偶","range":"150 °C 至 1768 °C","cmc":"0,6 °C"},{"name":"S 型热电偶","range":"-50 °C 至 0 °C","cmc":"1,1 °C"},{"name":"S 型热电偶","range":"0 °C 至 1768 °C","cmc":"0,8 °C"},{"name":"J 型热电偶","range":"-200 °C 至 0 °C","cmc":"0,3 °C"},{"name":"J 型热电偶","range":"0 °C 至 1200 °C","cmc":"0,4 °C"},{"name":"K 型热电偶","range":"-200 °C 至 1000 °C","cmc":"0,4 °C"},{"name":"K 型热电偶","range":"1000 °C 至 1372 °C","cmc":"0,5 °C"},{"name":"N 型热电偶","range":"-200 °C 至 -100 °C","cmc":"0,5 °C"},{"name":"N 型热电偶","range":"-100 °C 至 750 °C","cmc":"0,4 °C"},{"name":"N 型热电偶","range":"750 °C 至 1300 °C","cmc":"0,5 °C"}],"parameters_cs":[{"name":"TC typ B","range":"20 °C až 500 °C","cmc":"2,1 °C"},{"name":"TC typ B","range":"500 °C až 1820 °C","cmc":"0,9 °C"},{"name":"TC typ R","range":"-50 °C až 150 °C","cmc":"1,1 °C"},{"name":"TC typ R","range":"150 °C až 1768 °C","cmc":"0,6 °C"},{"name":"TC typ S","range":"-50 °C až 0 °C","cmc":"1,1 °C"},{"name":"TC typ S","range":"0 °C až 1768 °C","cmc":"0,8 °C"},{"name":"TC typ J","range":"-200 °C až 0 °C","cmc":"0,3 °C"},{"name":"TC typ J","range":"0 °C až 1200 °C","cmc":"0,4 °C"},{"name":"TC typ K","range":"-200 °C až 1000 °C","cmc":"0,4 °C"},{"name":"TC typ K","range":"1000 °C až 1372 °C","cmc":"0,5 °C"},{"name":"TC typ N","range":"-200 °C až -100 °C","cmc":"0,5 °C"},{"name":"TC typ N","range":"-100 °C až 750 °C","cmc":"0,4 °C"},{"name":"TC typ N","range":"750 °C až 1300 °C","cmc":"0,5 °C"}],"technique":"Symulacja wielofunkcyjnym kalibratorem Beamex MC5","technique_en":"Simulation with a Beamex MC5 multifunction calibrator","technique_zh":"用 Beamex MC5 多功能校准器模拟","technique_cs":"Simulace multifunkčním kalibrátorem Beamex MC5","techniques":["Symulacja wielofunkcyjnym kalibratorem Beamex MC5"],"techniques_en":["Simulation with a Beamex MC5 multifunction calibrator"],"techniques_zh":["用 Beamex MC5 多功能校准器模拟"],"techniques_cs":["Simulace multifunkčním kalibrátorem Beamex MC5"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nTC typu B od 20 °C do 500 °C CMC 2,1 °C\nTC typu B od 500 °C do 1820 °C CMC 0,9 °C\nTC typu R od -50 °C do 150 °C CMC 1,1 °C\nTC typu R od 150 °C do 1768 °C CMC 0,6 °C\nTC typu S od -50 °C do 0 °C CMC 1,1 °C\nTC typu S od 0 °C do 1768 °C CMC 0,8 °C\nTC typu J od -200 °C do 0 °C CMC 0,3 °C\nTC typu J od 0 °C do 1200 °C CMC 0,4 °C\nTC typu K od -200 °C do 1000 °C CMC 0,4 °C\nTC typu K od 1000 °C do 1372 °C CMC 0,5 °C\nTC typu N od -200 °C do -100 °C CMC 0,5 °C\nTC typu N od -100 °C do 750 °C CMC 0,4 °C\nTC typu N od 750 °C do 1300 °C CMC 0,5 °C\nSymulacja wielofunkcyjnym kalibratorem Beamex MC5","reference":"R01","norm_bases":["R01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Symulacja sygnałów wyjściowych termoelektrycznych czujników temperatury Wzorcowanie – temperatura Symulacja wielofunkcyjnym kalibratorem Beamex MC5 TC typu B od 20 °C do 500 °C CMC 2,1 °C TC typu B od 500 °C do 1820 °C CMC 0,9 °C TC typu R od -50 °C do 150 °C CMC 1,1 °C TC typu R od 150 °C do 1768 °C CMC 0,6 °C TC typu S od -50 °C do 0 °C CMC 1,1 °C TC typu S od 0 °C do 1768 °C CMC 0,8 °C TC typu J od -200 °C do 0 °C CMC 0,3 °C TC typu J od 0 °C do 1200 °C CMC 0,4 °C TC typu K od -200 °C do 1000 °C CMC 0,4 °C TC typu K od 1000 °C do 1372 °C CMC 0,5 °C TC typu N od -200 °C do -100 °C CMC 0,5 °C TC typu N od -100 °C do 750 °C CMC 0,4 °C TC typu N od 750 °C do 1300 °C CMC 0,5 °C Simulace výstupních signálů termoelektrických snímačů teploty Kalibrace – teplota Simulace multifunkčním kalibrátorem Beamex MC5 TC typ B 20 °C až 500 °C CMC 2,1 °C TC typ B 500 °C až 1820 °C CMC 0,9 °C TC typ R -50 °C až 150 °C CMC 1,1 °C TC typ R 150 °C až 1768 °C CMC 0,6 °C TC typ S -50 °C až 0 °C CMC 1,1 °C TC typ S 0 °C až 1768 °C CMC 0,8 °C TC typ J -200 °C až 0 °C CMC 0,3 °C TC typ J 0 °C až 1200 °C CMC 0,4 °C TC typ K -200 °C až 1000 °C CMC 0,4 °C TC typ K 1000 °C až 1372 °C CMC 0,5 °C TC typ N -200 °C až -100 °C CMC 0,5 °C TC typ N -100 °C až 750 °C CMC 0,4 °C TC typ N 750 °C až 1300 °C CMC 0,5 °C R01 Symulacja sygnalow wyjsciowych termoelektrycznych czujnikow temperatury Wzorcowanie – temperatura Symulacja wielofunkcyjnym kalibratorem Beamex MC5 TC typu B od 20 °C do 500 °C CMC 2,1 °C TC typu B od 500 °C do 1820 °C CMC 0,9 °C TC typu R od -50 °C do 150 °C CMC 1,1 °C TC typu R od 150 °C do 1768 °C CMC 0,6 °C TC typu S od -50 °C do 0 °C CMC 1,1 °C TC typu S od 0 °C do 1768 °C CMC 0,8 °C TC typu J od -200 °C do 0 °C CMC 0,3 °C TC typu J od 0 °C do 1200 °C CMC 0,4 °C TC typu K od -200 °C do 1000 °C CMC 0,4 °C TC typu K od 1000 °C do 1372 °C CMC 0,5 °C TC typu N od -200 °C do -100 °C CMC 0,5 °C TC typu N od -100 °C do 750 °C CMC 0,4 °C TC typu N od 750 °C do 1300 °C CMC 0,5 °C Simulace vystupnich signalu termoelektrickych snimacu teploty Kalibrace – teplota Simulace multifunkcnim kalibratorem Beamex MC5 TC typ B 20 °C az 500 °C CMC 2,1 °C TC typ B 500 °C az 1820 °C CMC 0,9 °C TC typ R -50 °C az 150 °C CMC 1,1 °C TC typ R 150 °C az 1768 °C CMC 0,6 °C TC typ S -50 °C az 0 °C CMC 1,1 °C TC typ S 0 °C az 1768 °C CMC 0,8 °C TC typ J -200 °C az 0 °C CMC 0,3 °C TC typ J 0 °C az 1200 °C CMC 0,4 °C TC typ K -200 °C az 1000 °C CMC 0,4 °C TC typ K 1000 °C az 1372 °C CMC 0,5 °C TC typ N -200 °C az -100 °C CMC 0,5 °C TC typ N -100 °C az 750 °C CMC 0,4 °C TC typ N 750 °C az 1300 °C CMC 0,5 °C R01","search_en":"Simulation of output signals of thermoelectric temperature sensors Calibration – temperature Simulation with a Beamex MC5 multifunction calibrator TC type B 20 °C to 500 °C CMC 2,1 °C TC type B 500 °C to 1820 °C CMC 0,9 °C TC type R -50 °C to 150 °C CMC 1,1 °C TC type R 150 °C to 1768 °C CMC 0,6 °C TC type S -50 °C to 0 °C CMC 1,1 °C TC type S 0 °C to 1768 °C CMC 0,8 °C TC type J -200 °C to 0 °C CMC 0,3 °C TC type J 0 °C to 1200 °C CMC 0,4 °C TC type K -200 °C to 1000 °C CMC 0,4 °C TC type K 1000 °C to 1372 °C CMC 0,5 °C TC type N -200 °C to -100 °C CMC 0,5 °C TC type N -100 °C to 750 °C CMC 0,4 °C TC type N 750 °C to 1300 °C CMC 0,5 °C R01","search_zh":"热电温度传感器输出信号的模拟 校准 – 温度 用 Beamex MC5 多功能校准器模拟 B 型热电偶 20 °C 至 500 °C CMC 2,1 °C B 型热电偶 500 °C 至 1820 °C CMC 0,9 °C R 型热电偶 -50 °C 至 150 °C CMC 1,1 °C R 型热电偶 150 °C 至 1768 °C CMC 0,6 °C S 型热电偶 -50 °C 至 0 °C CMC 1,1 °C S 型热电偶 0 °C 至 1768 °C CMC 0,8 °C J 型热电偶 -200 °C 至 0 °C CMC 0,3 °C J 型热电偶 0 °C 至 1200 °C CMC 0,4 °C K 型热电偶 -200 °C 至 1000 °C CMC 0,4 °C K 型热电偶 1000 °C 至 1372 °C CMC 0,5 °C N 型热电偶 -200 °C 至 -100 °C CMC 0,5 °C N 型热电偶 -100 °C 至 750 °C CMC 0,4 °C N 型热电偶 750 °C 至 1300 °C CMC 0,5 °C R01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14b014c4c8e2f8f767624e18","lab_id":"6ade8b37ff0682476170811b","country":"CZ","accr_number":"2337","accr_body":"ČIA","row_label":"6","test_object":"Wzorcowanie sygnałów wyjściowych czujników rezystancyjnych","test_object_en":"Calibration of output signals of resistance sensors","test_object_zh":"电阻传感器输出信号的校准","test_object_cs":"Kalibrace výstupních signálů odporových snímačů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Pt 100, Pt 1000","range":"od -200 °C do 0 °C","cmc":"0,12 °C"},{"name":"Pt 100, Pt 1000","range":"od 0 °C do 850 °C","cmc":"2,8·10⁻⁴ + 0,12 °C"}],"parameters_en":[{"name":"Pt 100, Pt 1000","range":"-200 °C to 0 °C","cmc":"0,12 °C"},{"name":"Pt 100, Pt 1000","range":"0 °C to 850 °C","cmc":"2,8·10⁻⁴ + 0,12 °C"}],"parameters_zh":[{"name":"Pt 100, Pt 1000","range":"-200 °C 至 0 °C","cmc":"0,12 °C"},{"name":"Pt 100, Pt 1000","range":"0 °C 至 850 °C","cmc":"2,8·10⁻⁴ + 0,12 °C"}],"parameters_cs":[{"name":"Pt 100, Pt 1000","range":"-200 °C až 0 °C","cmc":"0,12 °C"},{"name":"Pt 100, Pt 1000","range":"0 °C až 850 °C","cmc":"2,8·10⁻⁴ + 0,12 °C"}],"technique":"Symulacja wielofunkcyjnym kalibratorem Beamex MC5","technique_en":"Simulation with a Beamex MC5 multifunction calibrator","technique_zh":"用 Beamex MC5 多功能校准器模拟","technique_cs":"Simulace multifunkčním Kalibrátorem Beamex MC5","techniques":["Symulacja wielofunkcyjnym kalibratorem Beamex MC5"],"techniques_en":["Simulation with a Beamex MC5 multifunction calibrator"],"techniques_zh":["用 Beamex MC5 多功能校准器模拟"],"techniques_cs":["Simulace multifunkčním Kalibrátorem Beamex MC5"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nPt 100, Pt 1000 od -200 °C do 0 °C CMC 0,12 °C\nPt 100, Pt 1000 od 0 °C do 850 °C CMC 2,8·10⁻⁴ + 0,12 °C\nSymulacja wielofunkcyjnym kalibratorem Beamex MC5","reference":"R01","norm_bases":["R01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorcowanie sygnałów wyjściowych czujników rezystancyjnych Wzorcowanie – temperatura Symulacja wielofunkcyjnym kalibratorem Beamex MC5 Pt 100, Pt 1000 od -200 °C do 0 °C CMC 0,12 °C Pt 100, Pt 1000 od 0 °C do 850 °C CMC 2,8·10⁻⁴ + 0,12 °C Kalibrace výstupních signálů odporových snímačů Kalibrace – teplota Simulace multifunkčním Kalibrátorem Beamex MC5 Pt 100, Pt 1000 -200 °C až 0 °C CMC 0,12 °C Pt 100, Pt 1000 0 °C až 850 °C CMC 2,8·10⁻⁴ + 0,12 °C R01 Wzorcowanie sygnalow wyjsciowych czujnikow rezystancyjnych Wzorcowanie – temperatura Symulacja wielofunkcyjnym kalibratorem Beamex MC5 Pt 100, Pt 1000 od -200 °C do 0 °C CMC 0,12 °C Pt 100, Pt 1000 od 0 °C do 850 °C CMC 2,8·10⁻⁴ + 0,12 °C Kalibrace vystupnich signalu odporovych snimacu Kalibrace – teplota Simulace multifunkcnim Kalibratorem Beamex MC5 Pt 100, Pt 1000 -200 °C az 0 °C CMC 0,12 °C Pt 100, Pt 1000 0 °C az 850 °C CMC 2,8·10⁻⁴ + 0,12 °C R01","search_en":"Calibration of output signals of resistance sensors Calibration – temperature Simulation with a Beamex MC5 multifunction calibrator Pt 100, Pt 1000 -200 °C to 0 °C CMC 0,12 °C Pt 100, Pt 1000 0 °C to 850 °C CMC 2,8·10⁻⁴ + 0,12 °C R01","search_zh":"电阻传感器输出信号的校准 校准 – 温度 用 Beamex MC5 多功能校准器模拟 Pt 100, Pt 1000 -200 °C 至 0 °C CMC 0,12 °C Pt 100, Pt 1000 0 °C 至 850 °C CMC 2,8·10⁻⁴ + 0,12 °C R01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}