🇨🇿 Blue Panther s.r.o. PL
Metrology & calibration
Blue Panther s.r.o. is a calibration laboratory accredited by ČIA under number 2332 (Praha 4, Czech Republic). Its accreditation scope covers 36 calibration items in the following areas: Metrology & calibration. Calibrated items include: Insulation resistance / installation testers, multifunction testers…, AC active power / AC power meters, clamp meters, multifunction test…, AC apparent power / AC power meters, clamp meters, multifunction te…, AC current / AC current meters, calibrators, multimeters, clamp met…. Most frequently used calibration principles: Direct generation by a calibrator, Direct measurement by a multimeter, Power simulation by a calibrator with direct generation of the volt….
At a glance
- Accreditation number: ČIA 2332
- Calibration items in scope: 36
- Types of calibrated items: 24
- Calibration principles used: 17
- City: Praha 4, Czech Republic
- Valid until: 04-07-2028
- Accreditation number
- 2332
- Accreditation body
- ČIA
- Address
- Mezi Vodami 29, 143 00 Praha 4
- City
- Praha 4, Czech Republic
- Division
- Blue Panther Metrology
- Valid until
- 04-07-2028
What this laboratory calibrates (24)
- Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters — 3 calibration items
- AC active power / AC power meters, clamp meters, multifunction testers, power network analysers — 2 calibration items
- AC apparent power / AC power meters, clamp meters, multifunction testers, power network analysers — 2 calibration items
- AC current / AC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers — 2 calibration items
- AC current / AC current sources — 2 calibration items
- AC reactive power / AC power meters, clamp meters, multifunction testers, power network analysers — 2 calibration items
- AC voltage / AC voltage sources — 2 calibration items
- DC current / DC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers — 2 calibration items
- DC current / DC current sources — 2 calibration items
- DC power / DC power meters, clamp meters, multifunction testers, power network analysers — 2 calibration items
- DC voltage / DC voltage sources — 2 calibration items
- AC voltage / AC voltage meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers — 1 calibration item
- DC resistance / DC resistance meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers — 1 calibration item
- DC resistance / resistance decades, resistance standards, shunts, calibrators — 1 calibration item
- DC voltage / DC voltage meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers — 1 calibration item
- and 9 more
Calibration principles (17)
- Direct generation by a calibrator — 6 calibration items
- Direct measurement by a multimeter — 6 calibration items
- Power simulation by a calibrator with direct generation of the voltage and current components — 4 calibration items
- Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil — 4 calibration items
- Direct generation by an installation tester calibrator — 2 calibration items
- Direct measurement by an installation tester calibrator — 2 calibration items
- Indirect generation by a calibrator with current simulation by current coils — 2 calibration items
- Comparison by an installation tester calibrator — 1 calibration item
- Direct comparison with an installation tester calibrator — 1 calibration item
- Direct generation by a standard calibrator — 1 calibration item
- Direct measurement on a resistance decade — 1 calibration item
- Generation on a black body — 1 calibration item
- Indirect generation by a standard installation tester calibrator using a resistance multiplier — 1 calibration item
- Indirect measurement by an installation tester calibrator with a high-voltage divider — 1 calibration item
- Measurement by a multimeter with conversion from the output electrical signal — 1 calibration item
- and 2 more
Certificate information
- Certificate date
- 02.01.2025
Accreditation scope — calibration items (36)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Non-contact thermometers and non-contact thermometer measuring chains, thermal imagers, infrared thermometers, infrared temperature sensors | Calibration – temperature Emissivity 0.9 to 1; spectral band 8 µm to 14 µm — -15 °C to 200 °C · CMC 2 °C Emissivity 0.9 to 1; spectral band 8 µm to 14 µm — 200 °C to 350 °C · CMC 2,5 °C Emissivity 0.9 to 1; spectral band 8 µm to 14 µm — 350 °C to 500 °C · CMC 3,5 °C CMC for the field of measured quantity: Temperature |
Generation on a black body | VKP03/05 | |
| 2 | Temperature - electrical simulation / multimeters and thermometers with connectable resistance temperature probes or thermocouples, installation testers and multifunction testers with connectable thermocouples, process calibrators | Calibration – temperature Pt 385 (100 Ω) — -200 °C to -80 °C · CMC 0,04 °C Pt 385 (100 Ω) — -80 °C to 0 °C · CMC 0,04 °C Pt 385 (100 Ω) — 0 °C to 100 °C · CMC 0,05 °C Pt 385 (100 Ω) — 100 °C to 300 °C · CMC 0,07 °C Pt 385 (100 Ω) — 300 °C to 400 °C · CMC 0,08 °C Pt 385 (100 Ω) — 400 °C to 630 °C · CMC 0,09 °C Pt 385 (100 Ω) — 630 °C to 800 °C · CMC 0,18 °C Pt 3926 (100 Ω) — -200 °C to -80 °C · CMC 0,04 °C Pt 3926 (100 Ω) — -80 °C to 0 °C · CMC 0,04 °C Pt 3926 (100 Ω) — 0 °C to 100 °C · CMC 0,05 °C Pt 3926 (100 Ω) — 100 °C to 300 °C · CMC 0,07 °C Pt 3926 (100 Ω) — 300 °C to 400 °C · CMC 0,08 °C Pt 3926 (100 Ω) — 400 °C to 630 °C · CMC 0,09 °C Pt 3916 (100 Ω) — -200 °C to -190 °C · CMC 0,19 °C Pt 3916 (100 Ω) — -190 °C to -80 °C · CMC 0,03 °C Pt 3916 (100 Ω) — -80 °C to 0 °C · CMC 0,04 °C Pt 3916 (100 Ω) — 0 °C to 260 °C · CMC 0,05 °C Pt 3916 (100 Ω) — 260 °C to 300 °C · CMC 0,06 °C Pt 3916 (100 Ω) — 300 °C to 400 °C · CMC 0,07 °C Pt 3916 (100 Ω) — 400 °C to 600 °C · CMC 0,08 °C Pt 3916 (100 Ω) — 600 °C to 630 °C · CMC 0,18 °C Pt 385 (200 Ω) — -200 °C to 100 °C · CMC 0,03 °C Pt 385 (200 Ω) — 100 °C to 260 °C · CMC 0,04 °C Pt 385 (200 Ω) — 260 °C to 300 °C · CMC 0,09 °C Pt 385 (200 Ω) — 300 °C to 400 °C · CMC 0,10 °C Pt 385 (200 Ω) — 400 °C to 600 °C · CMC 0,11 °C Pt 385 (200 Ω) — 600 °C to 630 °C · CMC 0,12 °C Pt 385 (500 Ω) — -200 °C to -80 °C · CMC 0,03 °C Pt 385 (500 Ω) — -80 °C to 100 °C · CMC 0,04 °C Pt 385 (500 Ω) — 100 °C to 260 °C · CMC 0,05 °C Pt 385 (500 Ω) — 260 °C to 400 °C · CMC 0,06 °C Pt 385 (500 Ω) — 400 °C to 600 °C · CMC 0,07 °C Pt 385 (500 Ω) — 600 °C to 630 °C · CMC 0,09 °C Pt 385 (1000 Ω) — -200 °C to 0 °C · CMC 0,02 °C Pt 385 (1000 Ω) — 0 °C to 100 °C · CMC 0,03 °C Pt 385 (1000 Ω) — 100 °C to 260 °C · CMC 0,04 °C Pt 385 (1000 Ω) — 260 °C to 600 °C · CMC 0,05 °C Pt 385 (1000 Ω) — 600 °C to 630 °C · CMC 0,18 °C Ni 672 (120 Ω) — -80 °C to 100 °C · CMC 0,06 °C Ni 672 (120 Ω) — 100 °C to 260 °C · CMC 0,11 °C Cu 427 (10 Ω) — -80 to 260 °C · CMC 0,24 °C Cu 428 (50 Ω) — -180 to 200 °C · CMC 0,31 °C TC K — -200 °C to -100 °C · CMC 0,22 °C TC K — -100 °C to -25 °C · CMC 0,10 °C TC K — -25 °C to 120 °C · CMC 0,09 °C TC K — 120 °C to 1000 °C · CMC 0,16 °C TC K — 1000 °C to 1372 °C · CMC 0,27 °C TC J — -210 °C to -100 °C · CMC 0,19 °C TC J — -100 °C to -30 °C · CMC 0,10 °C TC J — -30 °C to 150 °C · CMC 0,09 °C TC J — 150 °C to 760 °C · CMC 0,11 °C TC J — 760 °C to 1200 °C · CMC 0,19 °C CMC for the field of measured quantity: Temperature |
Simulation of the sensor electrical input signal | VKP01/05 VKP02/05 | |
| 3 | Temperature - electrical simulation / simulators and sources of DC resistance equivalent to the temperature of a resistance temperature probe, simulators and sources of DC voltage equivalent to the thermocouple temperature, process calibrators | Calibration – temperature Pt 385 (100 Ω) — -200 °C to -80 °C · CMC 0,031 °C Pt 385 (100 Ω) — -80 °C to 100 °C · CMC 0,020 °C Pt 385 (100 Ω) — 100 °C to 300 °C · CMC 0,030 °C Pt 385 (100 Ω) — 300 °C to 400 °C · CMC 0,035 °C Pt 385 (100 Ω) — 400 °C to 630 °C · CMC 0,047 °C Pt 385 (100 Ω) — 630 °C to 800 °C · CMC 0,057 °C Pt 3926 (100 Ω) — -200 °C to -80 °C · CMC 0,031 °C Pt 3926 (100 Ω) — -80 °C to 0 °C · CMC 0,015 °C Pt 3926 (100 Ω) — 0 °C to 100 °C · CMC 0,019 °C Pt 3926 (100 Ω) — 100 °C to 300 °C · CMC 0,029 °C Pt 3926 (100 Ω) — 300 °C to 400 °C · CMC 0,034 °C Pt 3926 (100 Ω) — 400 °C to 630 °C · CMC 0,046 °C Pt 3916 (100 Ω) — -200 °C to -190 °C · CMC 0,028 °C Pt 3916 (100 Ω) — -190 °C to -80 °C · CMC 0,012 °C Pt 3916 (100 Ω) — -80 °C to 0 °C · CMC 0,015 °C Pt 3916 (100 Ω) — 0 °C to 100 °C · CMC 0,019 °C Pt 3916 (100 Ω) — 100 °C to 260 °C · CMC 0,028 °C Pt 3916 (100 Ω) — 260 °C to 300 °C · CMC 0,029 °C Pt 3916 (100 Ω) — 300 °C to 400 °C · CMC 0,034 °C Pt 3916 (100 Ω) — 400 °C to 600 °C · CMC 0,045 °C Pt 3916 (100 Ω) — 600 °C to 630 °C · CMC 0,047 °C Pt 385 (200 Ω) — -200 °C to -80 °C · CMC 0,072 °C Pt 385 (200 Ω) — -80 °C to 0 °C · CMC 0,076 °C Pt 385 (200 Ω) — 0 °C to 100 °C · CMC 0,079 °C Pt 385 (200 Ω) — 100 °C to 260 °C · CMC 0,082 °C Pt 385 (200 Ω) — 260 °C to 300 °C · CMC 0,090 °C Pt 385 (200 Ω) — 300 °C to 400 °C · CMC 0,093 °C Pt 385 (200 Ω) — 400 °C to 600 °C · CMC 0,10 °C Pt 385 (200 Ω) — 600 °C to 630 °C · CMC 0,10 °C Pt 385 (500 Ω) — -200 °C to -80 °C · CMC 0,047 °C Pt 385 (500 Ω) — -80 °C to 0 °C · CMC 0,050 °C Pt 385 (500 Ω) — 0 °C to 100 °C · CMC 0,045 °C Pt 385 (500 Ω) — 100 °C to 260 °C · CMC 0,033 °C Pt 385 (500 Ω) — 260 °C to 300 °C · CMC 0,035 °C Pt 385 (500 Ω) — 300 °C to 400 °C · CMC 0,041 °C Pt 385 (500 Ω) — 400 °C to 600 °C · CMC 0,052 °C Pt 385 (500 Ω) — 600 °C to 630 °C · CMC 0,076 °C Pt 385 (1000 Ω) — -200 °C to -80 °C · CMC 0,032 °C Pt 385 (1000 Ω) — -80 °C to 0 °C · CMC 0,035 °C Pt 385 (1000 Ω) — 0 °C to 100 °C · CMC 0,040 °C Pt 385 (1000 Ω) — 100 °C to 260 °C · CMC 0,028 °C Pt 385 (1000 Ω) — 260 °C to 300 °C · CMC 0,030 °C Pt 385 (1000 Ω) — 300 °C to 400 °C · CMC 0,034 °C Pt 385 (1000 Ω) — 400 °C to 600 °C · CMC 0,045 °C Pt 385 (1000 Ω) — 600 °C to 630 °C · CMC 0,047 °C PtNi 385 (120 Ω) — -80 °C to 0 °C · CMC 0,21 °C PtNi 385 (120 Ω) — 0 °C to 100 °C · CMC 0,21 °C PtNi 385 (120 Ω) — 100 °C to 260 °C · CMC 0,21 °C TC K — -200 °C to -100 °C · CMC 0,22 °C TC K — -100 °C to -25 °C · CMC 0,10 °C TC K — -25 °C to 120 °C · CMC 0,09 °C TC K — 120 °C to 1000 °C · CMC 0,16 °C TC K — 1000 °C to 1372 °C · CMC 0,27 °C TC J — -210 °C to -100 °C · CMC 0,19 °C TC J — -100 °C to -30 °C · CMC 0,10 °C TC J — -30 °C to 150 °C · CMC 0,09 °C TC J — 150 °C to 760 °C · CMC 0,11 °C TC J — 760 °C to 1200 °C · CMC 0,19 °C CMC for the field of measured quantity: Temperature |
Measurement by a multimeter with conversion from the output electrical signal | VKP01/05 | |
| 4 | DC voltage / DC voltage meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers | Calibration – electrical quantities 0 mV to 120 mV · CMC 9,3 µV/V +0,8 µV 120 mV to 1,2 V · CMC 6,4 µV/V +1 µV 1,2 V to 12 V · CMC 6,2 µV/V +10 µV 12 V to 120 V · CMC 8,5 µV/V +0,1 mV 120 V to 1020 V · CMC 8,5 µV/V +1 mV CMC for the field of measured quantity: Electrical quantities |
Direct generation by a calibrator | VKP01/05 VKP02/05 | |
| 5 | DC voltage / DC voltage sources | Calibration – electrical quantities 0 mV to 100 mV · CMC 0,025 % +3,5 µV 100 mV to 1 V · CMC 0,0018 % +7 µV 1 V to 10 V · CMC 0,0018 % +50 µV 10 V to 100 V · CMC 0,0027 % +0,6 mV 100 V to 1 kV · CMC 0,0031 % +10 mV CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a multimeter | VKP01/05 VKP02/05 | |
| 6 | DC voltage / DC voltage sources | Calibration – electrical quantities 1 kV to 10 kV · CMC 0,3 % +5 V CMC for the field of measured quantity: Electrical quantities |
Indirect measurement by an installation tester calibrator with a high-voltage divider | VKP01/05 VKP02/05 | |
| 7 | AC voltage / AC voltage meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers | Calibration – electrical quantities 3 Hz to 5 Hz — 1 mV to 12 mV · CMC 1 900 µV/V +7 µV 5 Hz to 10 Hz — 1 mV to 12 mV · CMC 680 µV/V +7 µV 10 Hz to 20 kHz — 1 mV to 12 mV · CMC 120 µV/V +6 µV 20 kHz to 50 kHz — 1 mV to 12 mV · CMC 290 µV/V +6 µV 50 kHz to 100 kHz — 1 mV to 12 mV · CMC 1200 µV/V +15 µV 100 kHz to 500 kHz — 1 mV to 12 mV · CMC 6 200 µV/V +30 µV 3 Hz to 5 Hz — 12 mV to 120 mV · CMC 1 900 µV/V +7 µV 5 Hz to 10 Hz — 12 mV to 120 mV · CMC 680 µV/V +7 µV 10 Hz to 20 kHz — 12 mV to 120 mV · CMC 110 µV/V +6 µV 20 kHz to 50 kHz — 12 mV to 120 mV · CMC 270 µV/V +8 µV 50 kHz to 100 kHz — 12 mV to 120 mV · CMC 620 µV/V +20 µV 100 kHz to 500 kHz — 12 mV to 120 mV · CMC 1 600 µV/V +30 µV 3 Hz to 5 Hz — 120 mV to 1,2 V · CMC 1 900 µV/V +75 µV 5 Hz to 10 Hz — 120 mV to 1,2 V · CMC 680 µV/V +70 µV 10 Hz to 40 Hz — 120 mV to 1,2 V · CMC 110 µV/V +60 µV 40,01 Hz to 20 kHz — 120 mV to 1,2 V · CMC 110 µV/V +8 µV 20 kHz to 50 kHz — 120 mV to 1,2 V · CMC 230 µV/V +14 µV 50 kHz to 100 kHz — 120 mV to 1,2 V · CMC 540 µV/V +40 µV 100 kHz to 500 kHz — 120 mV to 1,2 V · CMC 1 500 µV/V +80 µV 3 Hz to 5 Hz — 1,2 V to 12 V · CMC 1 900 µV/V +750 µV 5 Hz to 10 Hz — 1,2 V to 12 V · CMC 680 µV/V +750 µV 10 Hz to 40 Hz — 1,2 V to 12 V · CMC 110 µV/V +350 µV 40,01 Hz to 20 kHz — 1,2 V to 12 V · CMC 110 µV/V +50 µV 20 kHz to 50 kHz — 1,2 V to 12 V · CMC 230 µV/V +50 µV 50 kHz to 100 kHz — 1,2 V to 12 V · CMC 540 µV/V +125 µV 100 kHz to 500 kHz — 1,2 V to 12 V · CMC 1 600 µV/V +600 µV 3 Hz to 5 Hz — 12 V to 120 V · CMC 1 900 µV/V +7 500 µV 5 Hz to 10 Hz — 12 V to 120 V · CMC 680 µV/V +7 500 µV 10 Hz to 40 Hz — 12 V to 120 V · CMC 110 µV/V +3 500 µV 40,01 Hz to 20 kHz — 12 V to 120 V · CMC 110 µV/V +500 µV 20 kHz to 50 kHz — 12 V to 120 V · CMC 230 µV/V +500 µV 50 kHz to 100 kHz — 12 V to 120 V · CMC 540 µV/V +1 250 µV 100 kHz to 300 kHz (max. 70 V) — 12 V to 120 V · CMC 1 600 µV/V +20 mV 3 Hz to 5 Hz — 120 V to 330 V · CMC 1 900 µV/V +75 mV 5 Hz to 10 Hz — 120 V to 330 V · CMC 680 µV/V +75 mV 10 Hz to 20 kHz — 120 V to 330 V · CMC 110 µV/V +8 mV 20 kHz to 50 kHz — 120 V to 330 V · CMC 230 µV/V +8 mV 50 kHz to 100 kHz — 120 V to 330 V · CMC 1 200 µV/V +12,5 mV 3 Hz to 5 Hz — 330 V to 1020 V · CMC 1 900 µV/V +75 mV 5 Hz to 10 Hz — 330 V to 1020 V · CMC 680 µV/V +75 mV 10 Hz to 10 kHz — 330 V to 1020 V · CMC 110 µV/V +80 mV CMC for the field of measured quantity: Electrical quantities |
Direct generation by a calibrator | VKP01/05 VKP02/05 | |
| 8 | AC voltage / AC voltage sources | Calibration – electrical quantities 10 Hz to 20 kHz — 1 mV to 100 mV · CMC 0,05 % +40 µV 20 kHz to 50 kHz — 1 mV to 100 mV · CMC 0,11 % +50 µV 50 kHz to 100 kHz — 1 mV to 100 mV · CMC 0,6 % +80 µV 100 kHz to 300 kHz — 1 mV to 100 mV · CMC 4 % +0,5 mV 10 Hz to 20 kHz — 100 mV to 1 V · CMC 0,05 % +0,3 mV 20 kHz to 50 kHz — 100 mV to 1 V · CMC 0,11 % +0,5 mV 50 kHz to 100 kHz — 100 mV to 1 V · CMC 0,6 % +0,8 mV 100 kHz to 300 kHz — 100 mV to 1 V · CMC 4 % +5 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 0,05 % +3 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 0,11 % +5 mV 50 kHz to 100 kHz — 1 V to 10 V · CMC 0,6 % +8 mV 100 kHz to 300 kHz — 1 V to 10 V · CMC 4 % +50 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 0,05 % +30 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 0,11 % +50 mV 50 kHz to 100 kHz — 10 V to 100 V · CMC 0,6 % +80 mV 100 kHz to 300 kHz — 10 V to 100 V · CMC 4 % +0,5 V 10 Hz to 20 kHz — 100 V to 1 kV · CMC 0,05 % +0,3 V 20 kHz to 50 kHz — 100 V to 1 kV · CMC 0,11 % +0,5 V 50 kHz to 100 kHz (max. 8.10⁷ VHz) — 100 V to 1 kV · CMC 0,6 % +0,8 V 100 kHz to 300 kHz (max. 8.10⁷ VHz) — 100 V to 1 kV · CMC 4 % +5 V CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a multimeter | VKP01/05 VKP02/05 | |
| 9 | AC voltage / AC voltage sources | Calibration – electrical quantities 50 Hz to 60 Hz — 1 kV to 10 kV · CMC 0,5 % +5 V CMC for the field of measured quantity: Electrical quantities |
Measurement by an installation tester calibrator with a high-voltage divider | VKP01/05 VKP02/05 | |
| 10 | DC current / DC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers | Calibration – electrical quantities 0 µA to 120 µA · CMC 97 µA/A +6 nA 120 µA to 1,2 mA · CMC 78 µA/A +15 nA 1,2 mA to 12 mA · CMC 78 µA/A +80 nA 12 mA to 120 mA · CMC 78 µA/A +800 nA 120 mA to 1,2 A · CMC 120 µA/A +10 µA 1,2 A to 3,1 A · CMC 230 µA/A +150 µA 3,1 A to 12 A · CMC 230 µA/A +250 µA 12 A to 30,2 A · CMC 780 µA/A +500 µA CMC for the field of measured quantity: Electrical quantities |
Direct generation by a calibrator | VKP01/05 VKP02/05 | |
| 11 | DC current / DC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers | Calibration – electrical quantities 10 A to 16,5 A · CMC 0,5 % +20 mA 16,5 A to 150 A · CMC 0,5 % +0,14 A 150 A to 1000 A · CMC 0,5 % +0,5 A CMC for the field of measured quantity: Electrical quantities |
Indirect generation by a calibrator with current simulation by current coils | VKP01/05 VKP02/05 | |
| 12 | DC current / DC current sources | Calibration – electrical quantities 0 µA to 100 µA · CMC 0,04 % +0,025 µA 100 µA to 1 mA · CMC 0,03 % +0,05 µA 1 mA to 10 mA · CMC 0,03 % +2 µA 10 mA to 100 mA · CMC 0,03 % +5 µA 100 mA to 400 mA · CMC 0,04 % +5 µA 400 mA to 1 A · CMC 0,04 % +20 µA 1 A to 3 A · CMC 0,08 % +0,6 mA 3 A to 10 A · CMC 0,12 % +0,8 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a multimeter | VKP01/05 VKP02/05 | |
| 13 | DC current / DC current sources | Calibration – electrical quantities 10 A to 30 A · CMC 0,3 % +15 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement by an installation tester calibrator | VKP01/05 VKP02/05 | |
| 14 | AC current / AC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers | Calibration – electrical quantities 3 Hz to 5 kHz — 0,010 mA to 0,12 mA · CMC 190 µA/A +10 nA 5 kHz to 10 kHz — 0,010 mA to 0,12 mA · CMC 1 200 µA/A +40 nA 10 kHz to 30 kHz — 0,010 mA to 0,12 mA · CMC 3 900 µA/A +1 µA 3 Hz to 5 kHz — 0,12 mA to 1,2 mA · CMC 190 µA/A +100 nA 5 kHz to 10 kHz — 0,12 mA to 1,2 mA · CMC 1 200 µA/A +100 nA 10 kHz to 30 kHz — 0,12 mA to 1,2 mA · CMC 3 900 µA/A +5 µA 3 Hz to 5 kHz — 1,2 mA to 12 mA · CMC 190 µA/A +1 µA 5 kHz to 10 kHz — 1,2 mA to 12 mA · CMC 1 200 µA/A +1 µA 10 kHz to 30 kHz — 1,2 mA to 12 mA · CMC 3 900 µA/A +10 µA 3 Hz to 45 Hz — 12 mA to 120 mA · CMC 190 µA/A +10 µA 45 Hz to 1 kHz — 12 mA to 120 mA · CMC 120 µA/A +5 µA 1 kHz to 5 kHz — 12 mA to 120 mA · CMC 190 µA/A +8 µA 5 kHz to 10 kHz — 12 mA to 120 mA · CMC 1 200 µA/A +10 µA 10 kHz to 30 kHz — 12 mA to 120 mA · CMC 3 900 µA/A +100 µA 3 Hz to 45 Hz — 120 mA to 1,2 A · CMC 190 µA/A +100 µA 45 Hz to 1 kHz — 120 mA to 1,2 A · CMC 120 µA/A +50 µA 1 kHz to 5 kHz — 120 mA to 1,2 A · CMC 190 µA/A +80 µA 5 kHz to 10 kHz — 120 mA to 1,2 A · CMC 1 900 µA/A +300 µA 10 kHz to 30 kHz — 120 mA to 1,2 A · CMC 3 900 µA/A +300 µA 3 Hz to 45 Hz — 1,2 A to 3,1 A · CMC 290 µA/A +500 µA 45 Hz to 1 kHz — 1,2 A to 3,1 A · CMC 190 µA/A +300 µA 1 kHz to 5 kHz — 1,2 A to 3,1 A · CMC 290 µA/A +300 µA 5 kHz to 10 kHz — 1,2 A to 3,1 A · CMC 1 900 µA/A +500 µA 3 Hz to 45 Hz — 3,1 A to 12 A · CMC 290 µA/A +1 000 µA 45 Hz to 1 kHz — 3,1 A to 12 A · CMC 230 µA/A +500 µA 1 kHz to 5 kHz — 3,1 A to 12 A · CMC 290 µA/A +800 µA 5 kHz to 10 kHz — 3,1 A to 12 A · CMC 1 900 µA/A +1 000 µA 3 Hz to 45 Hz — 12 A to 30.2 A · CMC 780 µA/A +10 mA 45 Hz to 1 kHz — 12 A to 30.2 A · CMC 540 µA/A +8 mA 1 kHz to 5 kHz — 12 A to 30.2 A · CMC 3 900 µA/A +8 mA CMC for the field of measured quantity: Electrical quantities |
Direct generation by a calibrator | VKP01/05 VKP02/05 | |
| 15 | AC current / AC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers | Calibration – electrical quantities 45 Hz to 65 Hz — 10 A to 16,5 A · CMC 0,56 % +30 mA 65 Hz to 440 Hz — 10 A to 16,5 A · CMC 1,00 % +30 mA 45 Hz to 65 Hz — 16,5 A to 150 A · CMC 0,56 % +0,25 A 65 Hz to 440 Hz — 16,5 A to 150 A · CMC 1,00 % +0,25 A 45 Hz to 65 Hz — 150 A to 1000 A · CMC 0,56 % +0,9 A CMC for the field of measured quantity: Electrical quantities |
Indirect generation by a calibrator with current simulation by current coils | VKP01/05 VKP02/05 | |
| 16 | Leakage current / installation testers, multifunction testers, leakage current meters | Calibration – electrical quantities 50 Hz; passive — 100 µA to 30 mA · CMC 0,3 % +2 µA 50 Hz; differential — 100 µA to 30 mA · CMC 0,3 % +2 µA 50 Hz; substitute — 100 µA to 30 mA · CMC 0,3 % +2 µA 50 Hz; active — 100 µA to 30 mA · CMC 0,3 % +1 µA CMC for the field of measured quantity: Electrical quantities |
Direct comparison with an installation tester calibrator | VKP02/05 | |
| 17 | RCD tripping current / installation testers, multifunction testers, RCD testers | Calibration – electrical quantities 50 Hz — 3 mA to 3 A · CMC — CMC for the field of measured quantity: Electrical quantities |
Comparison by an installation tester calibrator | VKP02/05 | |
| 18 | AC current / AC current sources | Calibration – electrical quantities 10 Hz to 5 kHz — 10 µA to 100 µA · CMC 0,15 % +0,06 µA 5 kHz to 10 kHz — 10 µA to 100 µA · CMC 0,35 % +0,7 µA 10 Hz to 5 kHz — 100 µA to 1 mA · CMC 0,1 % +0,4 µA 5 kHz to 10 kHz — 100 µA to 1 mA · CMC 0,2 % +2,5 µA 10 Hz to 5 kHz — 1 mA to 10 mA · CMC 0,15 % +6 µA 5 kHz to 10 kHz — 1 mA to 10 mA · CMC 0,35 % +70 µA 10 Hz to 5 kHz — 10 mA to 100 mA · CMC 0,1 % +40 µA 5 kHz to 10 kHz — 10 mA to 100 mA · CMC 0,2 % +0,25 mA 10 Hz to 5 kHz — 100 mA to 400 mA · CMC 0,1 % +0,1 mA 5 kHz to 10 kHz — 100 mA to 400 mA · CMC 0,2 % +0,7 mA 10 Hz to 5 kHz — 400 mA to 1 A · CMC 0,1 % +0,4 mA 5 kHz to 10 kHz — 400 mA to 1 A · CMC 0,35 % +7 mA 10 Hz to 5 kHz — 1 A to 3 A · CMC 0,15 % +1,8 mA 5 kHz to 10 kHz — 1 A to 3 A · CMC 0,35 % +21 mA 10 Hz to 5 kHz — 3 A to 10 A · CMC 0,15 % +6 mA 5 kHz to 10 kHz — 3 A to 10 A · CMC 0,35 % +70 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a multimeter | VKP02/05 | |
| 19 | AC current / AC current sources | Calibration – electrical quantities 20 Hz to 400 Hz — 10 A to 30 A · CMC 0,3 % +15 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement by an installation tester calibrator | VKP02/05 | |
| 20 | DC resistance / DC resistance meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers | Calibration – electrical quantities 0 Ω to 12 Ω · CMC 19 µΩ/Ω +1 mΩ 12 Ω to 120 Ω · CMC 19 µΩ/Ω +1 mΩ 120 Ω to 1.2 kΩ · CMC 19 µΩ/Ω +2 mΩ 1,2 kΩ to 12 kΩ · CMC 19 µΩ/Ω +20 mΩ 12 kΩ to 120 kΩ · CMC 19 µΩ/Ω +200 mΩ 120 kΩ to 1,2 MΩ · CMC 19 µΩ/Ω +2 Ω 1,2 MΩ to 12 MΩ · CMC 27 µΩ/Ω +30 Ω 12 MΩ to 120 MΩ · CMC 330 µΩ/Ω +2,5 kΩ 120 MΩ to 1200 MΩ · CMC 3 100 µΩ/Ω +100 kΩ CMC for the field of measured quantity: Electrical quantities |
Direct generation by a standard calibrator | VKP01/05 VKP02/05 | |
| 21 | DC resistance / resistance decades, resistance standards, shunts, calibrators | Calibration – electrical quantities 0 Ω to 10 Ω · CMC 0,008 % +3 mΩ 10 Ω to 100 Ω · CMC 0,008 % +4 mΩ 100 Ω to 1000 Ω · CMC 0,008 % +0,01 Ω 1 kΩ to 10 kΩ · CMC 0,008 % +0,1 Ω 10 kΩ to 100 kΩ · CMC 0,008 % +1 Ω 100 kΩ to 1 MΩ · CMC 0,008 % +10 Ω 1 MΩ to 10 MΩ · CMC 0,02 % +0,1 kΩ 10 MΩ to 100 MΩ · CMC 0,8 % +10 kΩ 100 MΩ to 1 GΩ · CMC 1,5 % +0,1 MΩ CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a multimeter | VKP01/05 VKP02/05 | |
| 22 | Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters | Calibration – electrical quantities max. 55 V DC — 10 kΩ to 40 kΩ · CMC 0,2 % max. 300 V DC — 40 kΩ to 100 kΩ · CMC 0,2 % max. 800 V DC — 100 kΩ to 200 kΩ · CMC 0,2 % max. 1 100 V DC — 200 kΩ to 1 MΩ · CMC 0,2 % max. 1 100 V DC — 1 MΩ to 10 MΩ · CMC 0,3 % max. 1 575 V DC — 10 MΩ to 100 MΩ · CMC 0,5 % max. 1 575 V DC — 100 MΩ to 1 GΩ · CMC 1 % max. 1 575 V DC — 1 GΩ to 10 GΩ · CMC 3 % max. 1 575 V DC — 89,24 GΩ · CMC 5 % CMC for the field of measured quantity: Electrical quantities |
Direct generation by an installation tester calibrator | VKP02/05 | |
| 23 | Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters | Calibration – electrical quantities max. 10 kV DC — 350 MΩ to 1 GΩ · CMC 3,2 % max. 10 kV DC — 1 GΩ to 10 GΩ · CMC 3,3 % max. 10 kV DC — 10 GΩ to 100 GΩ · CMC 3,5 % max. 10 kV DC — 100 GΩ to 1 TΩ · CMC 4 % max. 10 kV DC — 1 TΩ to 10 TΩ · CMC 6 % CMC for the field of measured quantity: Electrical quantities |
Indirect generation by a standard installation tester calibrator using a resistance multiplier | VKP02/05 | |
| 24 | Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters | Calibration – electrical quantities max. 450 V DC — 100 kΩ · CMC 0,2 % max. 930 V DC — 300 kΩ · CMC 0,2 % max. 1 550 V DC — 500 kΩ · CMC 0,2 % max. 1 980 V DC — 1 MΩ · CMC 0,2 % max. 3 010 V DC — 3 MΩ · CMC 0,3 % max. 5 kV DC — 5 MΩ · CMC 0,3 % max. 5 kV DC — 10 MΩ to 100 MΩ · CMC 0,5 % max. 5 kV DC — 100 MΩ to 1 GΩ · CMC 1 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a resistance decade | VKP02/05 | |
| 25 | Fault loop impedance, network impedance, earthing impedance / installation testers, multifunction testers, network impedance meters, earth resistance meters, earthing meters | Calibration – electrical quantities 25 mΩ · CMC 5 mΩ 50 mΩ · CMC 5 mΩ 100 mΩ · CMC 5 mΩ 330 mΩ · CMC 7 mΩ 500 mΩ · CMC 8 mΩ 1000 mΩ · CMC 10 mΩ 1,8 Ω · CMC 18 mΩ 5 Ω · CMC 30 mΩ 10 Ω · CMC 60 mΩ 18 Ω · CMC 0,1 Ω 50 Ω · CMC 0,3 Ω 100 Ω · CMC 0,5 Ω 180 Ω · CMC 1 Ω 500 Ω · CMC 2,5 Ω 1000 Ω · CMC 5 Ω 1800 Ω · CMC 10 Ω CMC for the field of measured quantity: Electrical quantities |
Direct generation by an installation tester calibrator | VKP02/05 | |
| 26 | DC power / DC power meters, clamp meters, multifunction testers, power network analysers | Calibration – electrical quantities 0,1 A to 1,2 A; U = max. 1020 V — 0,1 W to 30,8 kW · CMC 0,013 % 1,2 A to 12 A; U = max. 1020 V — 0,1 W to 30,8 kW · CMC 0,025 % 12 A to 30,2 A; U = max. 1020 V — 0,1 W to 30,8 kW · CMC 0,08 % CMC for the field of measured quantity: Electrical quantities |
Power simulation by a calibrator with direct generation of the voltage and current components | VKP01/05 | |
| 27 | DC power / DC power meters, clamp meters, multifunction testers, power network analysers | Calibration – electrical quantities 10 A to 1000 A; U = max. 1020 V — 10 W to 1020 kW · CMC 0,5 % CMC for the field of measured quantity: Electrical quantities |
Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil | VKP01/05 | |
| 28 | AC active power / AC power meters, clamp meters, multifunction testers, power network analysers | Calibration – electrical quantities 45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 1 — 0,1 W to 30,08 kW · CMC 0,06 % 45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 0,9 — 0,09 W to 27,73 kW · CMC 0,12 % 45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 0,7 — 0,07 W to 21,55 kW · CMC 0,20 % 45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 0,5 — 0,05 W to 15,4 kW · CMC 0,38 % CMC for the field of measured quantity: Electrical quantities |
Power simulation by a calibrator with direct generation of the voltage and current components | VKP01/05 | |
| 29 | AC active power / AC power meters, clamp meters, multifunction testers, power network analysers | Calibration – electrical quantities I = max. 1 000 A; cos φ = 1 — 10 W to 1020 kW · CMC 0,50 % I = max. 1 000 A; cos φ = 0,9 — 9 W to 918 kW · CMC 0,52 % I = max. 1 000 A; cos φ = 0,7 — 7 W to 714 kW · CMC 0,54 % I = max. 1 000 A; cos φ = 0,5 — 5 W to 510 kW · CMC 0,63 % CMC for the field of measured quantity: Electrical quantities |
Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil | VKP01/05 | |
| 30 | AC apparent power / AC power meters, clamp meters, multifunction testers, power network analysers | Calibration – electrical quantities I = max. 30,2 A — 0,1 VA to 30,08 kVA · CMC 0,06 % CMC for the field of measured quantity: Electrical quantities |
Power simulation by a calibrator with direct generation of the voltage and current components | VKP01/05 | |
| 31 | AC apparent power / AC power meters, clamp meters, multifunction testers, power network analysers | Calibration – electrical quantities I = max. 1 000 A — 10 VA to 1020 kVA · CMC 0,50 % CMC for the field of measured quantity: Electrical quantities |
Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil | VKP01/05 | |
| 32 | AC reactive power / AC power meters, clamp meters, multifunction testers, power network analysers | Calibration – electrical quantities Cos φ = 0,5; I = max. 30,2 A — 0,05 VAr to 15,4 kVAr · CMC 0,38 % CMC for the field of measured quantity: Electrical quantities |
Power simulation by a calibrator with direct generation of the voltage and current components | VKP01/05 | |
| 33 | AC reactive power / AC power meters, clamp meters, multifunction testers, power network analysers | Calibration – electrical quantities I = max. 1 000 A — 5 VAr to 510 kVAr · CMC 0,63 % CMC for the field of measured quantity: Electrical quantities |
Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil | VKP01/05 | |
| 34 | Phase angle (voltage vs current) / AC power meters, clamp meters, multifunction testers, power network analysers | Calibration – electrical quantities 3 Hz to 65 Hz; U = min. 1 V — -180° to 180° · CMC 0,1° 65 Hz to 500 Hz; U = min. 1 V — -180° to 180° · CMC 0.2° 500 Hz to 1 kHz; U = min. 1 V — -180° to 180° · CMC 0.4° 1 kHz to 5 kHz; U = min. 1 V — -180° to 180° · CMC 1.9° 5 kHz to 10 kHz; U = min. 1 V — -180° to 180° · CMC 3.9° 10 kHz to 30 kHz; U = min. 1 V — -180° to 180° · CMC 7.8° CMC for the field of measured quantity: Electrical quantities |
Direct generation by a calibrator | VKP01/05 | |
| 35 | Frequency / AC voltage and current meters, AC power meters, power network analysers, multimeters, calibrators, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters | Calibration – frequency AC voltage — 10 Hz to 10 kHz · CMC 25 × 10⁻⁶ +1 mHz AC voltage — 10 kHz to 1 MHz · CMC 25 × 10⁻⁶ +15 mHz AC current — 10 Hz to 10 kHz · CMC 25 × 10⁻⁶ +1 mHz CMC for the field of measured quantity: Frequency |
Direct generation by a calibrator | VKP01/05 VKP02/05 | |
| 36 | Frequency / AC voltage sources | Calibration – frequency AC voltage — 10 Hz to 40 Hz · CMC 0,03 % AC voltage — 40 Hz to 300 kHz · CMC 0,01 % CMC for the field of measured quantity: Frequency |
Direct measurement by a multimeter | VKP01/05 VKP02/05 | |
Reference standards (3)
VKP01/05
VKP02/05
VKP03/05