{"lab":{"_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","address":"Mezi Vodami 29, 143 00 Praha 4","categories":["metrology"],"city":"Praha 4","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.40136,50.012566]},"map_coord":[50.012566,14.40136],"map_geo":"cai-mapa","methods_count":36,"name":"Blue Panther s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: temperatura, wielkości elektryczne i częstotliwość.","search_text":"blue panther s.r.o. mezi vodami 29, 143 00 praha 4 2332","source_page_url":"https://www.cai.cz/?subjekt=2332-blue-panther-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"04-07-2028","website":"https://www.blue-panther.cz/akreditovana-kalibracni-laborator","certificate_date":"02.01.2025","certificate_no":"1/2025","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: temperatura, wielkości elektryczne i częstotliwość.","en":"Calibration in the fields of temperature, electrical quantities and frequency.","zh":"温度、电学量和频率领域的校准。","cs":"Kalibrace v oborech teplota, elektrické veličiny a frekvence."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Blue Panther Metrology","lab_division_cs":"Blue Panther Metrology","lab_division_en":"Blue Panther Metrology","lab_division_zh":"Blue Panther Metrology 计量实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"617fa56ba2b5a4d0611caba59a550bb6281d1848dd8944dbb5d975c3e5e1a772","source_pdf_url":"https://www.cai.cz/OA/pdf/P1_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"0096ff401554baeb66401bff","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezdotykowe i tory pomiarowe termometrów bezdotykowych, kamery termowizyjne, termometry na podczerwień, czujniki temperatury na podczerwień","test_object_en":"Non-contact thermometers and non-contact thermometer measuring chains, thermal imagers, infrared thermometers, infrared temperature sensors","test_object_zh":"非接触式温度计及其测量链、热像仪、红外温度计、红外温度传感器","test_object_cs":"Bezdotykové teploměry a měřicí řetězce bezdotykových teploměrů, termokamery, infračervené teploměry, infračervené teplotní senzory","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Emisyjność 0,9 do 1; pasmo widmowe 8 µm do 14 µm","range":"od -15 °C do 200 °C","cmc":"2 °C"},{"name":"Emisyjność 0,9 do 1; pasmo widmowe 8 µm do 14 µm","range":"od 200 °C do 350 °C","cmc":"2,5 °C"},{"name":"Emisyjność 0,9 do 1; pasmo widmowe 8 µm do 14 µm","range":"od 350 °C do 500 °C","cmc":"3,5 °C"}],"parameters_en":[{"name":"Emissivity 0.9 to 1; spectral band 8 µm to 14 µm","range":"-15 °C to 200 °C","cmc":"2 °C"},{"name":"Emissivity 0.9 to 1; spectral band 8 µm to 14 µm","range":"200 °C to 350 °C","cmc":"2,5 °C"},{"name":"Emissivity 0.9 to 1; spectral band 8 µm to 14 µm","range":"350 °C to 500 °C","cmc":"3,5 °C"}],"parameters_zh":[{"name":"发射率 0,9 至 1；光谱波段 8 µm 至 14 µm","range":"-15 °C 至 200 °C","cmc":"2 °C"},{"name":"发射率 0,9 至 1；光谱波段 8 µm 至 14 µm","range":"200 °C 至 350 °C","cmc":"2,5 °C"},{"name":"发射率 0,9 至 1；光谱波段 8 µm 至 14 µm","range":"350 °C 至 500 °C","cmc":"3,5 °C"}],"parameters_cs":[{"name":"Emisivita 0,9 až 1; Spektrální pásmo 8 µm až 14 µm","range":"-15 °C až 200 °C","cmc":"2 °C"},{"name":"Emisivita 0,9 až 1; Spektrální pásmo 8 µm až 14 µm","range":"200 °C až 350 °C","cmc":"2,5 °C"},{"name":"Emisivita 0,9 až 1; Spektrální pásmo 8 µm až 14 µm","range":"350 °C až 500 °C","cmc":"3,5 °C"}],"technique":"Generowanie na ciele czarnym","technique_en":"Generation on a black body","technique_zh":"在黑体上产生","technique_cs":"Generování na černém tělese","techniques":["Generowanie na ciele czarnym"],"techniques_en":["Generation on a black body"],"techniques_zh":["在黑体上产生"],"techniques_cs":["Generování na černém tělese"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nEmisyjność 0,9 do 1; pasmo widmowe 8 µm do 14 µm od -15 °C do 200 °C CMC 2 °C\nEmisyjność 0,9 do 1; pasmo widmowe 8 µm do 14 µm od 200 °C do 350 °C CMC 2,5 °C\nEmisyjność 0,9 do 1; pasmo widmowe 8 µm do 14 µm od 350 °C do 500 °C CMC 3,5 °C\nGenerowanie na ciele czarnym","reference":"VKP03/05","norm_bases":["VKP03/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezdotykowe i tory pomiarowe termometrów bezdotykowych, kamery termowizyjne, termometry na podczerwień, czujniki temperatury na podczerwień Wzorcowanie – temperatura Generowanie na ciele czarnym Emisyjność 0,9 do 1; pasmo widmowe 8 µm do 14 µm od -15 °C do 200 °C CMC 2 °C Emisyjność 0,9 do 1; pasmo widmowe 8 µm do 14 µm od 200 °C do 350 °C CMC 2,5 °C Emisyjność 0,9 do 1; pasmo widmowe 8 µm do 14 µm od 350 °C do 500 °C CMC 3,5 °C Bezdotykové teploměry a měřicí řetězce bezdotykových teploměrů, termokamery, infračervené teploměry, infračervené teplotní senzory Kalibrace – teplota Generování na černém tělese Emisivita 0,9 až 1; Spektrální pásmo 8 µm až 14 µm -15 °C až 200 °C CMC 2 °C Emisivita 0,9 až 1; Spektrální pásmo 8 µm až 14 µm 200 °C až 350 °C CMC 2,5 °C Emisivita 0,9 až 1; Spektrální pásmo 8 µm až 14 µm 350 °C až 500 °C CMC 3,5 °C VKP03/05 Termometry bezdotykowe i tory pomiarowe termometrow bezdotykowych, kamery termowizyjne, termometry na podczerwien, czujniki temperatury na podczerwien Wzorcowanie – temperatura Generowanie na ciele czarnym Emisyjnosc 0,9 do 1; pasmo widmowe 8 µm do 14 µm od -15 °C do 200 °C CMC 2 °C Emisyjnosc 0,9 do 1; pasmo widmowe 8 µm do 14 µm od 200 °C do 350 °C CMC 2,5 °C Emisyjnosc 0,9 do 1; pasmo widmowe 8 µm do 14 µm od 350 °C do 500 °C CMC 3,5 °C Bezdotykove teplomery a merici retezce bezdotykovych teplomeru, termokamery, infracervene teplomery, infracervene teplotni senzory Kalibrace – teplota Generovani na cernem telese Emisivita 0,9 az 1; Spektralni pasmo 8 µm az 14 µm -15 °C az 200 °C CMC 2 °C Emisivita 0,9 az 1; Spektralni pasmo 8 µm az 14 µm 200 °C az 350 °C CMC 2,5 °C Emisivita 0,9 az 1; Spektralni pasmo 8 µm az 14 µm 350 °C az 500 °C CMC 3,5 °C VKP03/05","search_en":"Non-contact thermometers and non-contact thermometer measuring chains, thermal imagers, infrared thermometers, infrared temperature sensors Calibration – temperature Generation on a black body Emissivity 0.9 to 1; spectral band 8 µm to 14 µm -15 °C to 200 °C CMC 2 °C Emissivity 0.9 to 1; spectral band 8 µm to 14 µm 200 °C to 350 °C CMC 2,5 °C Emissivity 0.9 to 1; spectral band 8 µm to 14 µm 350 °C to 500 °C CMC 3,5 °C VKP03/05","search_zh":"非接触式温度计及其测量链、热像仪、红外温度计、红外温度传感器 校准 – 温度 在黑体上产生 发射率 0,9 至 1；光谱波段 8 µm 至 14 µm -15 °C 至 200 °C CMC 2 °C 发射率 0,9 至 1；光谱波段 8 µm 至 14 µm 200 °C 至 350 °C CMC 2,5 °C 发射率 0,9 至 1；光谱波段 8 µm 至 14 µm 350 °C 至 500 °C CMC 3,5 °C VKP03/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7197b84c47778da1da99709d","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"2","test_object":"Temperatura - symulacja elektryczna / multimetry i termometry z możliwością podłączenia rezystancyjnych sond temperatury lub termopar, mierniki do badań instalacji i testery wielofunkcyjne z możliwością podłączenia termopar, kalibratory procesowe","test_object_en":"Temperature - electrical simulation / multimeters and thermometers with connectable resistance temperature probes or thermocouples, installation testers and multifunction testers with connectable thermocouples, process calibrators","test_object_zh":"温度 - 电模拟 / 可连接电阻温度探头或热电偶的万用表和温度计、可连接热电偶的电气安装测试仪和多功能测试仪、过程校准器","test_object_cs":"Teplota - elektrická simulace / multimetry a teploměry s možností připojení odporových teplotních sond nebo termočlánků, revizní měřidla a multifunkční testery s možností připojení termočlánků, procesní kalibrátory","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Pt 385 (100 Ω)","range":"od -200 °C do -80 °C","cmc":"0,04 °C"},{"name":"Pt 385 (100 Ω)","range":"od -80 °C do 0 °C","cmc":"0,04 °C"},{"name":"Pt 385 (100 Ω)","range":"od 0 °C do 100 °C","cmc":"0,05 °C"},{"name":"Pt 385 (100 Ω)","range":"od 100 °C do 300 °C","cmc":"0,07 °C"},{"name":"Pt 385 (100 Ω)","range":"od 300 °C do 400 °C","cmc":"0,08 °C"},{"name":"Pt 385 (100 Ω)","range":"od 400 °C do 630 °C","cmc":"0,09 °C"},{"name":"Pt 385 (100 Ω)","range":"od 630 °C do 800 °C","cmc":"0,18 °C"},{"name":"Pt 3926 (100 Ω)","range":"od -200 °C do -80 °C","cmc":"0,04 °C"},{"name":"Pt 3926 (100 Ω)","range":"od -80 °C do 0 °C","cmc":"0,04 °C"},{"name":"Pt 3926 (100 Ω)","range":"od 0 °C do 100 °C","cmc":"0,05 °C"},{"name":"Pt 3926 (100 Ω)","range":"od 100 °C do 300 °C","cmc":"0,07 °C"},{"name":"Pt 3926 (100 Ω)","range":"od 300 °C do 400 °C","cmc":"0,08 °C"},{"name":"Pt 3926 (100 Ω)","range":"od 400 °C do 630 °C","cmc":"0,09 °C"},{"name":"Pt 3916 (100 Ω)","range":"od -200 °C do -190 °C","cmc":"0,19 °C"},{"name":"Pt 3916 (100 Ω)","range":"od -190 °C do -80 °C","cmc":"0,03 °C"},{"name":"Pt 3916 (100 Ω)","range":"od -80 °C do 0 °C","cmc":"0,04 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 0 °C do 260 °C","cmc":"0,05 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 260 °C do 300 °C","cmc":"0,06 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 300 °C do 400 °C","cmc":"0,07 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 400 °C do 600 °C","cmc":"0,08 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 600 °C do 630 °C","cmc":"0,18 °C"},{"name":"Pt 385 (200 Ω)","range":"od -200 °C do 100 °C","cmc":"0,03 °C"},{"name":"Pt 385 (200 Ω)","range":"od 100 °C do 260 °C","cmc":"0,04 °C"},{"name":"Pt 385 (200 Ω)","range":"od 260 °C do 300 °C","cmc":"0,09 °C"},{"name":"Pt 385 (200 Ω)","range":"od 300 °C do 400 °C","cmc":"0,10 °C"},{"name":"Pt 385 (200 Ω)","range":"od 400 °C do 600 °C","cmc":"0,11 °C"},{"name":"Pt 385 (200 Ω)","range":"od 600 °C do 630 °C","cmc":"0,12 °C"},{"name":"Pt 385 (500 Ω)","range":"od -200 °C do -80 °C","cmc":"0,03 °C"},{"name":"Pt 385 (500 Ω)","range":"od -80 °C do 100 °C","cmc":"0,04 °C"},{"name":"Pt 385 (500 Ω)","range":"od 100 °C do 260 °C","cmc":"0,05 °C"},{"name":"Pt 385 (500 Ω)","range":"od 260 °C do 400 °C","cmc":"0,06 °C"},{"name":"Pt 385 (500 Ω)","range":"od 400 °C do 600 °C","cmc":"0,07 °C"},{"name":"Pt 385 (500 Ω)","range":"od 600 °C do 630 °C","cmc":"0,09 °C"},{"name":"Pt 385 (1000 Ω)","range":"od -200 °C do 0 °C","cmc":"0,02 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 0 °C do 100 °C","cmc":"0,03 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 100 °C do 260 °C","cmc":"0,04 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 260 °C do 600 °C","cmc":"0,05 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 600 °C do 630 °C","cmc":"0,18 °C"},{"name":"Ni 672 (120 Ω)","range":"od -80 °C do 100 °C","cmc":"0,06 °C"},{"name":"Ni 672 (120 Ω)","range":"od 100 °C do 260 °C","cmc":"0,11 °C"},{"name":"Cu 427 (10 Ω)","range":"od -80 do 260 °C","cmc":"0,24 °C"},{"name":"Cu 428 (50 Ω)","range":"od -180 do 200 °C","cmc":"0,31 °C"},{"name":"TC K","range":"od -200 °C do -100 °C","cmc":"0,22 °C"},{"name":"TC K","range":"od -100 °C do -25 °C","cmc":"0,10 °C"},{"name":"TC K","range":"od -25 °C do 120 °C","cmc":"0,09 °C"},{"name":"TC K","range":"od 120 °C do 1000 °C","cmc":"0,16 °C"},{"name":"TC K","range":"od 1000 °C do 1372 °C","cmc":"0,27 °C"},{"name":"TC J","range":"od -210 °C do -100 °C","cmc":"0,19 °C"},{"name":"TC J","range":"od -100 °C do -30 °C","cmc":"0,10 °C"},{"name":"TC J","range":"od -30 °C do 150 °C","cmc":"0,09 °C"},{"name":"TC J","range":"od 150 °C do 760 °C","cmc":"0,11 °C"},{"name":"TC J","range":"od 760 °C do 1200 °C","cmc":"0,19 °C"}],"parameters_en":[{"name":"Pt 385 (100 Ω)","range":"-200 °C to -80 °C","cmc":"0,04 °C"},{"name":"Pt 385 (100 Ω)","range":"-80 °C to 0 °C","cmc":"0,04 °C"},{"name":"Pt 385 (100 Ω)","range":"0 °C to 100 °C","cmc":"0,05 °C"},{"name":"Pt 385 (100 Ω)","range":"100 °C to 300 °C","cmc":"0,07 °C"},{"name":"Pt 385 (100 Ω)","range":"300 °C to 400 °C","cmc":"0,08 °C"},{"name":"Pt 385 (100 Ω)","range":"400 °C to 630 °C","cmc":"0,09 °C"},{"name":"Pt 385 (100 Ω)","range":"630 °C to 800 °C","cmc":"0,18 °C"},{"name":"Pt 3926 (100 Ω)","range":"-200 °C to -80 °C","cmc":"0,04 °C"},{"name":"Pt 3926 (100 Ω)","range":"-80 °C to 0 °C","cmc":"0,04 °C"},{"name":"Pt 3926 (100 Ω)","range":"0 °C to 100 °C","cmc":"0,05 °C"},{"name":"Pt 3926 (100 Ω)","range":"100 °C to 300 °C","cmc":"0,07 °C"},{"name":"Pt 3926 (100 Ω)","range":"300 °C to 400 °C","cmc":"0,08 °C"},{"name":"Pt 3926 (100 Ω)","range":"400 °C to 630 °C","cmc":"0,09 °C"},{"name":"Pt 3916 (100 Ω)","range":"-200 °C to -190 °C","cmc":"0,19 °C"},{"name":"Pt 3916 (100 Ω)","range":"-190 °C to -80 °C","cmc":"0,03 °C"},{"name":"Pt 3916 (100 Ω)","range":"-80 °C to 0 °C","cmc":"0,04 °C"},{"name":"Pt 3916 (100 Ω)","range":"0 °C to 260 °C","cmc":"0,05 °C"},{"name":"Pt 3916 (100 Ω)","range":"260 °C to 300 °C","cmc":"0,06 °C"},{"name":"Pt 3916 (100 Ω)","range":"300 °C to 400 °C","cmc":"0,07 °C"},{"name":"Pt 3916 (100 Ω)","range":"400 °C to 600 °C","cmc":"0,08 °C"},{"name":"Pt 3916 (100 Ω)","range":"600 °C to 630 °C","cmc":"0,18 °C"},{"name":"Pt 385 (200 Ω)","range":"-200 °C to 100 °C","cmc":"0,03 °C"},{"name":"Pt 385 (200 Ω)","range":"100 °C to 260 °C","cmc":"0,04 °C"},{"name":"Pt 385 (200 Ω)","range":"260 °C to 300 °C","cmc":"0,09 °C"},{"name":"Pt 385 (200 Ω)","range":"300 °C to 400 °C","cmc":"0,10 °C"},{"name":"Pt 385 (200 Ω)","range":"400 °C to 600 °C","cmc":"0,11 °C"},{"name":"Pt 385 (200 Ω)","range":"600 °C to 630 °C","cmc":"0,12 °C"},{"name":"Pt 385 (500 Ω)","range":"-200 °C to -80 °C","cmc":"0,03 °C"},{"name":"Pt 385 (500 Ω)","range":"-80 °C to 100 °C","cmc":"0,04 °C"},{"name":"Pt 385 (500 Ω)","range":"100 °C to 260 °C","cmc":"0,05 °C"},{"name":"Pt 385 (500 Ω)","range":"260 °C to 400 °C","cmc":"0,06 °C"},{"name":"Pt 385 (500 Ω)","range":"400 °C to 600 °C","cmc":"0,07 °C"},{"name":"Pt 385 (500 Ω)","range":"600 °C to 630 °C","cmc":"0,09 °C"},{"name":"Pt 385 (1000 Ω)","range":"-200 °C to 0 °C","cmc":"0,02 °C"},{"name":"Pt 385 (1000 Ω)","range":"0 °C to 100 °C","cmc":"0,03 °C"},{"name":"Pt 385 (1000 Ω)","range":"100 °C to 260 °C","cmc":"0,04 °C"},{"name":"Pt 385 (1000 Ω)","range":"260 °C to 600 °C","cmc":"0,05 °C"},{"name":"Pt 385 (1000 Ω)","range":"600 °C to 630 °C","cmc":"0,18 °C"},{"name":"Ni 672 (120 Ω)","range":"-80 °C to 100 °C","cmc":"0,06 °C"},{"name":"Ni 672 (120 Ω)","range":"100 °C to 260 °C","cmc":"0,11 °C"},{"name":"Cu 427 (10 Ω)","range":"-80 to 260 °C","cmc":"0,24 °C"},{"name":"Cu 428 (50 Ω)","range":"-180 to 200 °C","cmc":"0,31 °C"},{"name":"TC K","range":"-200 °C to -100 °C","cmc":"0,22 °C"},{"name":"TC K","range":"-100 °C to -25 °C","cmc":"0,10 °C"},{"name":"TC K","range":"-25 °C to 120 °C","cmc":"0,09 °C"},{"name":"TC K","range":"120 °C to 1000 °C","cmc":"0,16 °C"},{"name":"TC K","range":"1000 °C to 1372 °C","cmc":"0,27 °C"},{"name":"TC J","range":"-210 °C to -100 °C","cmc":"0,19 °C"},{"name":"TC J","range":"-100 °C to -30 °C","cmc":"0,10 °C"},{"name":"TC J","range":"-30 °C to 150 °C","cmc":"0,09 °C"},{"name":"TC J","range":"150 °C to 760 °C","cmc":"0,11 °C"},{"name":"TC J","range":"760 °C to 1200 °C","cmc":"0,19 °C"}],"parameters_zh":[{"name":"Pt 385 (100 Ω)","range":"-200 °C 至 -80 °C","cmc":"0,04 °C"},{"name":"Pt 385 (100 Ω)","range":"-80 °C 至 0 °C","cmc":"0,04 °C"},{"name":"Pt 385 (100 Ω)","range":"0 °C 至 100 °C","cmc":"0,05 °C"},{"name":"Pt 385 (100 Ω)","range":"100 °C 至 300 °C","cmc":"0,07 °C"},{"name":"Pt 385 (100 Ω)","range":"300 °C 至 400 °C","cmc":"0,08 °C"},{"name":"Pt 385 (100 Ω)","range":"400 °C 至 630 °C","cmc":"0,09 °C"},{"name":"Pt 385 (100 Ω)","range":"630 °C 至 800 °C","cmc":"0,18 °C"},{"name":"Pt 3926 (100 Ω)","range":"-200 °C 至 -80 °C","cmc":"0,04 °C"},{"name":"Pt 3926 (100 Ω)","range":"-80 °C 至 0 °C","cmc":"0,04 °C"},{"name":"Pt 3926 (100 Ω)","range":"0 °C 至 100 °C","cmc":"0,05 °C"},{"name":"Pt 3926 (100 Ω)","range":"100 °C 至 300 °C","cmc":"0,07 °C"},{"name":"Pt 3926 (100 Ω)","range":"300 °C 至 400 °C","cmc":"0,08 °C"},{"name":"Pt 3926 (100 Ω)","range":"400 °C 至 630 °C","cmc":"0,09 °C"},{"name":"Pt 3916 (100 Ω)","range":"-200 °C 至 -190 °C","cmc":"0,19 °C"},{"name":"Pt 3916 (100 Ω)","range":"-190 °C 至 -80 °C","cmc":"0,03 °C"},{"name":"Pt 3916 (100 Ω)","range":"-80 °C 至 0 °C","cmc":"0,04 °C"},{"name":"Pt 3916 (100 Ω)","range":"0 °C 至 260 °C","cmc":"0,05 °C"},{"name":"Pt 3916 (100 Ω)","range":"260 °C 至 300 °C","cmc":"0,06 °C"},{"name":"Pt 3916 (100 Ω)","range":"300 °C 至 400 °C","cmc":"0,07 °C"},{"name":"Pt 3916 (100 Ω)","range":"400 °C 至 600 °C","cmc":"0,08 °C"},{"name":"Pt 3916 (100 Ω)","range":"600 °C 至 630 °C","cmc":"0,18 °C"},{"name":"Pt 385 (200 Ω)","range":"-200 °C 至 100 °C","cmc":"0,03 °C"},{"name":"Pt 385 (200 Ω)","range":"100 °C 至 260 °C","cmc":"0,04 °C"},{"name":"Pt 385 (200 Ω)","range":"260 °C 至 300 °C","cmc":"0,09 °C"},{"name":"Pt 385 (200 Ω)","range":"300 °C 至 400 °C","cmc":"0,10 °C"},{"name":"Pt 385 (200 Ω)","range":"400 °C 至 600 °C","cmc":"0,11 °C"},{"name":"Pt 385 (200 Ω)","range":"600 °C 至 630 °C","cmc":"0,12 °C"},{"name":"Pt 385 (500 Ω)","range":"-200 °C 至 -80 °C","cmc":"0,03 °C"},{"name":"Pt 385 (500 Ω)","range":"-80 °C 至 100 °C","cmc":"0,04 °C"},{"name":"Pt 385 (500 Ω)","range":"100 °C 至 260 °C","cmc":"0,05 °C"},{"name":"Pt 385 (500 Ω)","range":"260 °C 至 400 °C","cmc":"0,06 °C"},{"name":"Pt 385 (500 Ω)","range":"400 °C 至 600 °C","cmc":"0,07 °C"},{"name":"Pt 385 (500 Ω)","range":"600 °C 至 630 °C","cmc":"0,09 °C"},{"name":"Pt 385 (1000 Ω)","range":"-200 °C 至 0 °C","cmc":"0,02 °C"},{"name":"Pt 385 (1000 Ω)","range":"0 °C 至 100 °C","cmc":"0,03 °C"},{"name":"Pt 385 (1000 Ω)","range":"100 °C 至 260 °C","cmc":"0,04 °C"},{"name":"Pt 385 (1000 Ω)","range":"260 °C 至 600 °C","cmc":"0,05 °C"},{"name":"Pt 385 (1000 Ω)","range":"600 °C 至 630 °C","cmc":"0,18 °C"},{"name":"Ni 672 (120 Ω)","range":"-80 °C 至 100 °C","cmc":"0,06 °C"},{"name":"Ni 672 (120 Ω)","range":"100 °C 至 260 °C","cmc":"0,11 °C"},{"name":"Cu 427 (10 Ω)","range":"-80 至 260 °C","cmc":"0,24 °C"},{"name":"Cu 428 (50 Ω)","range":"-180 至 200 °C","cmc":"0,31 °C"},{"name":"K 型热电偶","range":"-200 °C 至 -100 °C","cmc":"0,22 °C"},{"name":"K 型热电偶","range":"-100 °C 至 -25 °C","cmc":"0,10 °C"},{"name":"K 型热电偶","range":"-25 °C 至 120 °C","cmc":"0,09 °C"},{"name":"K 型热电偶","range":"120 °C 至 1000 °C","cmc":"0,16 °C"},{"name":"K 型热电偶","range":"1000 °C 至 1372 °C","cmc":"0,27 °C"},{"name":"J 型热电偶","range":"-210 °C 至 -100 °C","cmc":"0,19 °C"},{"name":"J 型热电偶","range":"-100 °C 至 -30 °C","cmc":"0,10 °C"},{"name":"J 型热电偶","range":"-30 °C 至 150 °C","cmc":"0,09 °C"},{"name":"J 型热电偶","range":"150 °C 至 760 °C","cmc":"0,11 °C"},{"name":"J 型热电偶","range":"760 °C 至 1200 °C","cmc":"0,19 °C"}],"parameters_cs":[{"name":"Pt 385 (100 Ω)","range":"-200 °C až -80 °C","cmc":"0,04 °C"},{"name":"Pt 385 (100 Ω)","range":"-80 °C až 0 °C","cmc":"0,04 °C"},{"name":"Pt 385 (100 Ω)","range":"0 °C až 100 °C","cmc":"0,05 °C"},{"name":"Pt 385 (100 Ω)","range":"100 °C až 300 °C","cmc":"0,07 °C"},{"name":"Pt 385 (100 Ω)","range":"300 °C až 400 °C","cmc":"0,08 °C"},{"name":"Pt 385 (100 Ω)","range":"400 °C až 630 °C","cmc":"0,09 °C"},{"name":"Pt 385 (100 Ω)","range":"630 °C až 800 °C","cmc":"0,18 °C"},{"name":"Pt 3926 (100 Ω)","range":"-200 °C až -80 °C","cmc":"0,04 °C"},{"name":"Pt 3926 (100 Ω)","range":"-80 °C až 0 °C","cmc":"0,04 °C"},{"name":"Pt 3926 (100 Ω)","range":"0 °C až 100 °C","cmc":"0,05 °C"},{"name":"Pt 3926 (100 Ω)","range":"100 °C až 300 °C","cmc":"0,07 °C"},{"name":"Pt 3926 (100 Ω)","range":"300 °C až 400 °C","cmc":"0,08 °C"},{"name":"Pt 3926 (100 Ω)","range":"400 °C až 630 °C","cmc":"0,09 °C"},{"name":"Pt 3916 (100 Ω)","range":"-200 °C až -190 °C","cmc":"0,19 °C"},{"name":"Pt 3916 (100 Ω)","range":"-190 °C až -80 °C","cmc":"0,03 °C"},{"name":"Pt 3916 (100 Ω)","range":"-80 °C až 0 °C","cmc":"0,04 °C"},{"name":"Pt 3916 (100 Ω)","range":"0 °C až 260 °C","cmc":"0,05 °C"},{"name":"Pt 3916 (100 Ω)","range":"260 °C až 300 °C","cmc":"0,06 °C"},{"name":"Pt 3916 (100 Ω)","range":"300 °C až 400 °C","cmc":"0,07 °C"},{"name":"Pt 3916 (100 Ω)","range":"400 °C až 600 °C","cmc":"0,08 °C"},{"name":"Pt 3916 (100 Ω)","range":"600 °C až 630 °C","cmc":"0,18 °C"},{"name":"Pt 385 (200 Ω)","range":"-200 °C až 100 °C","cmc":"0,03 °C"},{"name":"Pt 385 (200 Ω)","range":"100 °C až 260 °C","cmc":"0,04 °C"},{"name":"Pt 385 (200 Ω)","range":"260 °C až 300 °C","cmc":"0,09 °C"},{"name":"Pt 385 (200 Ω)","range":"300 °C až 400 °C","cmc":"0,10 °C"},{"name":"Pt 385 (200 Ω)","range":"400 °C až 600 °C","cmc":"0,11 °C"},{"name":"Pt 385 (200 Ω)","range":"600 °C až 630 °C","cmc":"0,12 °C"},{"name":"Pt 385 (500 Ω)","range":"-200 °C až -80 °C","cmc":"0,03 °C"},{"name":"Pt 385 (500 Ω)","range":"-80 °C až 100 °C","cmc":"0,04 °C"},{"name":"Pt 385 (500 Ω)","range":"100 °C až 260 °C","cmc":"0,05 °C"},{"name":"Pt 385 (500 Ω)","range":"260 °C až 400 °C","cmc":"0,06 °C"},{"name":"Pt 385 (500 Ω)","range":"400 °C až 600 °C","cmc":"0,07 °C"},{"name":"Pt 385 (500 Ω)","range":"600 °C až 630 °C","cmc":"0,09 °C"},{"name":"Pt 385 (1000 Ω)","range":"-200 °C až 0 °C","cmc":"0,02 °C"},{"name":"Pt 385 (1000 Ω)","range":"0 °C až 100 °C","cmc":"0,03 °C"},{"name":"Pt 385 (1000 Ω)","range":"100 °C až 260 °C","cmc":"0,04 °C"},{"name":"Pt 385 (1000 Ω)","range":"260 °C až 600 °C","cmc":"0,05 °C"},{"name":"Pt 385 (1000 Ω)","range":"600 °C až 630 °C","cmc":"0,18 °C"},{"name":"Ni 672 (120 Ω)","range":"-80 °C až 100 °C","cmc":"0,06 °C"},{"name":"Ni 672 (120 Ω)","range":"100 °C až 260 °C","cmc":"0,11 °C"},{"name":"Cu 427 (10 Ω)","range":"-80 až 260 °C","cmc":"0,24 °C"},{"name":"Cu 428 (50 Ω)","range":"-180 až 200 °C","cmc":"0,31 °C"},{"name":"TC K","range":"-200 °C až -100 °C","cmc":"0,22 °C"},{"name":"TC K","range":"-100 °C až -25 °C","cmc":"0,10 °C"},{"name":"TC K","range":"-25 °C až 120 °C","cmc":"0,09 °C"},{"name":"TC K","range":"120 °C až 1000 °C","cmc":"0,16 °C"},{"name":"TC K","range":"1000 °C až 1372 °C","cmc":"0,27 °C"},{"name":"TC J","range":"-210 °C až -100 °C","cmc":"0,19 °C"},{"name":"TC J","range":"-100 °C až -30 °C","cmc":"0,10 °C"},{"name":"TC J","range":"-30 °C až 150 °C","cmc":"0,09 °C"},{"name":"TC J","range":"150 °C až 760 °C","cmc":"0,11 °C"},{"name":"TC J","range":"760 °C až 1200 °C","cmc":"0,19 °C"}],"technique":"Symulacja elektrycznego sygnału wejściowego czujnika","technique_en":"Simulation of the sensor electrical input signal","technique_zh":"模拟传感器电输入信号","technique_cs":"Simulace elektrického vstupního signálu snímače","techniques":["Symulacja elektrycznego sygnału wejściowego czujnika"],"techniques_en":["Simulation of the sensor electrical input signal"],"techniques_zh":["模拟传感器电输入信号"],"techniques_cs":["Simulace elektrického vstupního signálu snímače"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nPt 385 (100 Ω) od -200 °C do -80 °C CMC 0,04 °C\nPt 385 (100 Ω) od -80 °C do 0 °C CMC 0,04 °C\nPt 385 (100 Ω) od 0 °C do 100 °C CMC 0,05 °C\nPt 385 (100 Ω) od 100 °C do 300 °C CMC 0,07 °C\nPt 385 (100 Ω) od 300 °C do 400 °C CMC 0,08 °C\nPt 385 (100 Ω) od 400 °C do 630 °C CMC 0,09 °C\nPt 385 (100 Ω) od 630 °C do 800 °C CMC 0,18 °C\nPt 3926 (100 Ω) od -200 °C do -80 °C CMC 0,04 °C\nPt 3926 (100 Ω) od -80 °C do 0 °C CMC 0,04 °C\nPt 3926 (100 Ω) od 0 °C do 100 °C CMC 0,05 °C\nPt 3926 (100 Ω) od 100 °C do 300 °C CMC 0,07 °C\nPt 3926 (100 Ω) od 300 °C do 400 °C CMC 0,08 °C\nPt 3926 (100 Ω) od 400 °C do 630 °C CMC 0,09 °C\nPt 3916 (100 Ω) od -200 °C do -190 °C CMC 0,19 °C\nPt 3916 (100 Ω) od -190 °C do -80 °C CMC 0,03 °C\nPt 3916 (100 Ω) od -80 °C do 0 °C CMC 0,04 °C\nPt 3916 (100 Ω) od 0 °C do 260 °C CMC 0,05 °C\nPt 3916 (100 Ω) od 260 °C do 300 °C CMC 0,06 °C\nPt 3916 (100 Ω) od 300 °C do 400 °C CMC 0,07 °C\nPt 3916 (100 Ω) od 400 °C do 600 °C CMC 0,08 °C\nPt 3916 (100 Ω) od 600 °C do 630 °C CMC 0,18 °C\nPt 385 (200 Ω) od -200 °C do 100 °C CMC 0,03 °C\nPt 385 (200 Ω) od 100 °C do 260 °C CMC 0,04 °C\nPt 385 (200 Ω) od 260 °C do 300 °C CMC 0,09 °C\nPt 385 (200 Ω) od 300 °C do 400 °C CMC 0,10 °C\nPt 385 (200 Ω) od 400 °C do 600 °C CMC 0,11 °C\nPt 385 (200 Ω) od 600 °C do 630 °C CMC 0,12 °C\nPt 385 (500 Ω) od -200 °C do -80 °C CMC 0,03 °C\nPt 385 (500 Ω) od -80 °C do 100 °C CMC 0,04 °C\nPt 385 (500 Ω) od 100 °C do 260 °C CMC 0,05 °C\nPt 385 (500 Ω) od 260 °C do 400 °C CMC 0,06 °C\nPt 385 (500 Ω) od 400 °C do 600 °C CMC 0,07 °C\nPt 385 (500 Ω) od 600 °C do 630 °C CMC 0,09 °C\nPt 385 (1000 Ω) od -200 °C do 0 °C CMC 0,02 °C\nPt 385 (1000 Ω) od 0 °C do 100 °C CMC 0,03 °C\nPt 385 (1000 Ω) od 100 °C do 260 °C CMC 0,04 °C\nPt 385 (1000 Ω) od 260 °C do 600 °C CMC 0,05 °C\nPt 385 (1000 Ω) od 600 °C do 630 °C CMC 0,18 °C\nNi 672 (120 Ω) od -80 °C do 100 °C CMC 0,06 °C\nNi 672 (120 Ω) od 100 °C do 260 °C CMC 0,11 °C\nCu 427 (10 Ω) od -80 do 260 °C CMC 0,24 °C\nCu 428 (50 Ω) od -180 do 200 °C CMC 0,31 °C\nTC K od -200 °C do -100 °C CMC 0,22 °C\nTC K od -100 °C do -25 °C CMC 0,10 °C\nTC K od -25 °C do 120 °C CMC 0,09 °C\nTC K od 120 °C do 1000 °C CMC 0,16 °C\nTC K od 1000 °C do 1372 °C CMC 0,27 °C\nTC J od -210 °C do -100 °C CMC 0,19 °C\nTC J od -100 °C do -30 °C CMC 0,10 °C\nTC J od -30 °C do 150 °C CMC 0,09 °C\nTC J od 150 °C do 760 °C CMC 0,11 °C\nTC J od 760 °C do 1200 °C CMC 0,19 °C\nSymulacja elektrycznego sygnału wejściowego czujnika","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Temperatura - symulacja elektryczna / multimetry i termometry z możliwością podłączenia rezystancyjnych sond temperatury lub termopar, mierniki do badań instalacji i testery wielofunkcyjne z możliwością podłączenia termopar, kalibratory procesowe Wzorcowanie – temperatura Symulacja elektrycznego sygnału wejściowego czujnika Pt 385 (100 Ω) od -200 °C do -80 °C CMC 0,04 °C Pt 385 (100 Ω) od -80 °C do 0 °C CMC 0,04 °C Pt 385 (100 Ω) od 0 °C do 100 °C CMC 0,05 °C Pt 385 (100 Ω) od 100 °C do 300 °C CMC 0,07 °C Pt 385 (100 Ω) od 300 °C do 400 °C CMC 0,08 °C Pt 385 (100 Ω) od 400 °C do 630 °C CMC 0,09 °C Pt 385 (100 Ω) od 630 °C do 800 °C CMC 0,18 °C Pt 3926 (100 Ω) od -200 °C do -80 °C CMC 0,04 °C Pt 3926 (100 Ω) od -80 °C do 0 °C CMC 0,04 °C Pt 3926 (100 Ω) od 0 °C do 100 °C CMC 0,05 °C Pt 3926 (100 Ω) od 100 °C do 300 °C CMC 0,07 °C Pt 3926 (100 Ω) od 300 °C do 400 °C CMC 0,08 °C Pt 3926 (100 Ω) od 400 °C do 630 °C CMC 0,09 °C Pt 3916 (100 Ω) od -200 °C do -190 °C CMC 0,19 °C Pt 3916 (100 Ω) od -190 °C do -80 °C CMC 0,03 °C Pt 3916 (100 Ω) od -80 °C do 0 °C CMC 0,04 °C Pt 3916 (100 Ω) od 0 °C do 260 °C CMC 0,05 °C Pt 3916 (100 Ω) od 260 °C do 300 °C CMC 0,06 °C Pt 3916 (100 Ω) od 300 °C do 400 °C CMC 0,07 °C Pt 3916 (100 Ω) od 400 °C do 600 °C CMC 0,08 °C Pt 3916 (100 Ω) od 600 °C do 630 °C CMC 0,18 °C Pt 385 (200 Ω) od -200 °C do 100 °C CMC 0,03 °C Pt 385 (200 Ω) od 100 °C do 260 °C CMC 0,04 °C Pt 385 (200 Ω) od 260 °C do 300 °C CMC 0,09 °C Pt 385 (200 Ω) od 300 °C do 400 °C CMC 0,10 °C Pt 385 (200 Ω) od 400 °C do 600 °C CMC 0,11 °C Pt 385 (200 Ω) od 600 °C do 630 °C CMC 0,12 °C Pt 385 (500 Ω) od -200 °C do -80 °C CMC 0,03 °C Pt 385 (500 Ω) od -80 °C do 100 °C CMC 0,04 °C Pt 385 (500 Ω) od 100 °C do 260 °C CMC 0,05 °C Pt 385 (500 Ω) od 260 °C do 400 °C CMC 0,06 °C Pt 385 (500 Ω) od 400 °C do 600 °C CMC 0,07 °C Pt 385 (500 Ω) od 600 °C do 630 °C CMC 0,09 °C Pt 385 (1000 Ω) od -200 °C do 0 °C CMC 0,02 °C Pt 385 (1000 Ω) od 0 °C do 100 °C CMC 0,03 °C Pt 385 (1000 Ω) od 100 °C do 260 °C CMC 0,04 °C Pt 385 (1000 Ω) od 260 °C do 600 °C CMC 0,05 °C Pt 385 (1000 Ω) od 600 °C do 630 °C CMC 0,18 °C Ni 672 (120 Ω) od -80 °C do 100 °C CMC 0,06 °C Ni 672 (120 Ω) od 100 °C do 260 °C CMC 0,11 °C Cu 427 (10 Ω) od -80 do 260 °C CMC 0,24 °C Cu 428 (50 Ω) od -180 do 200 °C CMC 0,31 °C TC K od -200 °C do -100 °C CMC 0,22 °C TC K od -100 °C do -25 °C CMC 0,10 °C TC K od -25 °C do 120 °C CMC 0,09 °C TC K od 120 °C do 1000 °C CMC 0,16 °C TC K od 1000 °C do 1372 °C CMC 0,27 °C TC J od -210 °C do -100 °C CMC 0,19 °C TC J od -100 °C do -30 °C CMC 0,10 °C TC J od -30 °C do 150 °C CMC 0,09 °C TC J od 150 °C do 760 °C CMC 0,11 °C TC J od 760 °C do 1200 °C CMC 0,19 °C Teplota - elektrická simulace / multimetry a teploměry s možností připojení odporových teplotních sond nebo termočlánků, revizní měřidla a multifunkční testery s možností připojení termočlánků, procesní kalibrátory Kalibrace – teplota Simulace elektrického vstupního signálu snímače Pt 385 (100 Ω) -200 °C až -80 °C CMC 0,04 °C Pt 385 (100 Ω) -80 °C až 0 °C CMC 0,04 °C Pt 385 (100 Ω) 0 °C až 100 °C CMC 0,05 °C Pt 385 (100 Ω) 100 °C až 300 °C CMC 0,07 °C Pt 385 (100 Ω) 300 °C až 400 °C CMC 0,08 °C Pt 385 (100 Ω) 400 °C až 630 °C CMC 0,09 °C Pt 385 (100 Ω) 630 °C až 800 °C CMC 0,18 °C Pt 3926 (100 Ω) -200 °C až -80 °C CMC 0,04 °C Pt 3926 (100 Ω) -80 °C až 0 °C CMC 0,04 °C Pt 3926 (100 Ω) 0 °C až 100 °C CMC 0,05 °C Pt 3926 (100 Ω) 100 °C až 300 °C CMC 0,07 °C Pt 3926 (100 Ω) 300 °C až 400 °C CMC 0,08 °C Pt 3926 (100 Ω) 400 °C až 630 °C CMC 0,09 °C Pt 3916 (100 Ω) -200 °C až -190 °C CMC 0,19 °C Pt 3916 (100 Ω) -190 °C až -80 °C CMC 0,03 °C Pt 3916 (100 Ω) -80 °C až 0 °C CMC 0,04 °C Pt 3916 (100 Ω) 0 °C až 260 °C CMC 0,05 °C Pt 3916 (100 Ω) 260 °C až 300 °C CMC 0,06 °C Pt 3916 (100 Ω) 300 °C až 400 °C CMC 0,07 °C Pt 3916 (100 Ω) 400 °C až 600 °C CMC 0,08 °C Pt 3916 (100 Ω) 600 °C až 630 °C CMC 0,18 °C Pt 385 (200 Ω) -200 °C až 100 °C CMC 0,03 °C Pt 385 (200 Ω) 100 °C až 260 °C CMC 0,04 °C Pt 385 (200 Ω) 260 °C až 300 °C CMC 0,09 °C Pt 385 (200 Ω) 300 °C až 400 °C CMC 0,10 °C Pt 385 (200 Ω) 400 °C až 600 °C CMC 0,11 °C Pt 385 (200 Ω) 600 °C až 630 °C CMC 0,12 °C Pt 385 (500 Ω) -200 °C až -80 °C CMC 0,03 °C Pt 385 (500 Ω) -80 °C až 100 °C CMC 0,04 °C Pt 385 (500 Ω) 100 °C až 260 °C CMC 0,05 °C Pt 385 (500 Ω) 260 °C až 400 °C CMC 0,06 °C Pt 385 (500 Ω) 400 °C až 600 °C CMC 0,07 °C Pt 385 (500 Ω) 600 °C až 630 °C CMC 0,09 °C Pt 385 (1000 Ω) -200 °C až 0 °C CMC 0,02 °C Pt 385 (1000 Ω) 0 °C až 100 °C CMC 0,03 °C Pt 385 (1000 Ω) 100 °C až 260 °C CMC 0,04 °C Pt 385 (1000 Ω) 260 °C až 600 °C CMC 0,05 °C Pt 385 (1000 Ω) 600 °C až 630 °C CMC 0,18 °C Ni 672 (120 Ω) -80 °C až 100 °C CMC 0,06 °C Ni 672 (120 Ω) 100 °C až 260 °C CMC 0,11 °C Cu 427 (10 Ω) -80 až 260 °C CMC 0,24 °C Cu 428 (50 Ω) -180 až 200 °C CMC 0,31 °C TC K -200 °C až -100 °C CMC 0,22 °C TC K -100 °C až -25 °C CMC 0,10 °C TC K -25 °C až 120 °C CMC 0,09 °C TC K 120 °C až 1000 °C CMC 0,16 °C TC K 1000 °C až 1372 °C CMC 0,27 °C TC J -210 °C až -100 °C CMC 0,19 °C TC J -100 °C až -30 °C CMC 0,10 °C TC J -30 °C až 150 °C CMC 0,09 °C TC J 150 °C až 760 °C CMC 0,11 °C TC J 760 °C až 1200 °C CMC 0,19 °C VKP01/05 VKP02/05 Temperatura - symulacja elektryczna / multimetry i termometry z mozliwoscia podlaczenia rezystancyjnych sond temperatury lub termopar, mierniki do badan instalacji i testery wielofunkcyjne z mozliwoscia podlaczenia termopar, kalibratory procesowe Wzorcowanie – temperatura Symulacja elektrycznego sygnalu wejsciowego czujnika Pt 385 (100 Ω) od -200 °C do -80 °C CMC 0,04 °C Pt 385 (100 Ω) od -80 °C do 0 °C CMC 0,04 °C Pt 385 (100 Ω) od 0 °C do 100 °C CMC 0,05 °C Pt 385 (100 Ω) od 100 °C do 300 °C CMC 0,07 °C Pt 385 (100 Ω) od 300 °C do 400 °C CMC 0,08 °C Pt 385 (100 Ω) od 400 °C do 630 °C CMC 0,09 °C Pt 385 (100 Ω) od 630 °C do 800 °C CMC 0,18 °C Pt 3926 (100 Ω) od -200 °C do -80 °C CMC 0,04 °C Pt 3926 (100 Ω) od -80 °C do 0 °C CMC 0,04 °C Pt 3926 (100 Ω) od 0 °C do 100 °C CMC 0,05 °C Pt 3926 (100 Ω) od 100 °C do 300 °C CMC 0,07 °C Pt 3926 (100 Ω) od 300 °C do 400 °C CMC 0,08 °C Pt 3926 (100 Ω) od 400 °C do 630 °C CMC 0,09 °C Pt 3916 (100 Ω) od -200 °C do -190 °C CMC 0,19 °C Pt 3916 (100 Ω) od -190 °C do -80 °C CMC 0,03 °C Pt 3916 (100 Ω) od -80 °C do 0 °C CMC 0,04 °C Pt 3916 (100 Ω) od 0 °C do 260 °C CMC 0,05 °C Pt 3916 (100 Ω) od 260 °C do 300 °C CMC 0,06 °C Pt 3916 (100 Ω) od 300 °C do 400 °C CMC 0,07 °C Pt 3916 (100 Ω) od 400 °C do 600 °C CMC 0,08 °C Pt 3916 (100 Ω) od 600 °C do 630 °C CMC 0,18 °C Pt 385 (200 Ω) od -200 °C do 100 °C CMC 0,03 °C Pt 385 (200 Ω) od 100 °C do 260 °C CMC 0,04 °C Pt 385 (200 Ω) od 260 °C do 300 °C CMC 0,09 °C Pt 385 (200 Ω) od 300 °C do 400 °C CMC 0,10 °C Pt 385 (200 Ω) od 400 °C do 600 °C CMC 0,11 °C Pt 385 (200 Ω) od 600 °C do 630 °C CMC 0,12 °C Pt 385 (500 Ω) od -200 °C do -80 °C CMC 0,03 °C Pt 385 (500 Ω) od -80 °C do 100 °C CMC 0,04 °C Pt 385 (500 Ω) od 100 °C do 260 °C CMC 0,05 °C Pt 385 (500 Ω) od 260 °C do 400 °C CMC 0,06 °C Pt 385 (500 Ω) od 400 °C do 600 °C CMC 0,07 °C Pt 385 (500 Ω) od 600 °C do 630 °C CMC 0,09 °C Pt 385 (1000 Ω) od -200 °C do 0 °C CMC 0,02 °C Pt 385 (1000 Ω) od 0 °C do 100 °C CMC 0,03 °C Pt 385 (1000 Ω) od 100 °C do 260 °C CMC 0,04 °C Pt 385 (1000 Ω) od 260 °C do 600 °C CMC 0,05 °C Pt 385 (1000 Ω) od 600 °C do 630 °C CMC 0,18 °C Ni 672 (120 Ω) od -80 °C do 100 °C CMC 0,06 °C Ni 672 (120 Ω) od 100 °C do 260 °C CMC 0,11 °C Cu 427 (10 Ω) od -80 do 260 °C CMC 0,24 °C Cu 428 (50 Ω) od -180 do 200 °C CMC 0,31 °C TC K od -200 °C do -100 °C CMC 0,22 °C TC K od -100 °C do -25 °C CMC 0,10 °C TC K od -25 °C do 120 °C CMC 0,09 °C TC K od 120 °C do 1000 °C CMC 0,16 °C TC K od 1000 °C do 1372 °C CMC 0,27 °C TC J od -210 °C do -100 °C CMC 0,19 °C TC J od -100 °C do -30 °C CMC 0,10 °C TC J od -30 °C do 150 °C CMC 0,09 °C TC J od 150 °C do 760 °C CMC 0,11 °C TC J od 760 °C do 1200 °C CMC 0,19 °C Teplota - elektricka simulace / multimetry a teplomery s moznosti pripojeni odporovych teplotnich sond nebo termoclanku, revizni meridla a multifunkcni testery s moznosti pripojeni termoclanku, procesni kalibratory Kalibrace – teplota Simulace elektrickeho vstupniho signalu snimace Pt 385 (100 Ω) -200 °C az -80 °C CMC 0,04 °C Pt 385 (100 Ω) -80 °C az 0 °C CMC 0,04 °C Pt 385 (100 Ω) 0 °C az 100 °C CMC 0,05 °C Pt 385 (100 Ω) 100 °C az 300 °C CMC 0,07 °C Pt 385 (100 Ω) 300 °C az 400 °C CMC 0,08 °C Pt 385 (100 Ω) 400 °C az 630 °C CMC 0,09 °C Pt 385 (100 Ω) 630 °C az 800 °C CMC 0,18 °C Pt 3926 (100 Ω) -200 °C az -80 °C CMC 0,04 °C Pt 3926 (100 Ω) -80 °C az 0 °C CMC 0,04 °C Pt 3926 (100 Ω) 0 °C az 100 °C CMC 0,05 °C Pt 3926 (100 Ω) 100 °C az 300 °C CMC 0,07 °C Pt 3926 (100 Ω) 300 °C az 400 °C CMC 0,08 °C Pt 3926 (100 Ω) 400 °C az 630 °C CMC 0,09 °C Pt 3916 (100 Ω) -200 °C az -190 °C CMC 0,19 °C Pt 3916 (100 Ω) -190 °C az -80 °C CMC 0,03 °C Pt 3916 (100 Ω) -80 °C az 0 °C CMC 0,04 °C Pt 3916 (100 Ω) 0 °C az 260 °C CMC 0,05 °C Pt 3916 (100 Ω) 260 °C az 300 °C CMC 0,06 °C Pt 3916 (100 Ω) 300 °C az 400 °C CMC 0,07 °C Pt 3916 (100 Ω) 400 °C az 600 °C CMC 0,08 °C Pt 3916 (100 Ω) 600 °C az 630 °C CMC 0,18 °C Pt 385 (200 Ω) -200 °C az 100 °C CMC 0,03 °C Pt 385 (200 Ω) 100 °C az 260 °C CMC 0,04 °C Pt 385 (200 Ω) 260 °C az 300 °C CMC 0,09 °C Pt 385 (200 Ω) 300 °C az 400 °C CMC 0,10 °C Pt 385 (200 Ω) 400 °C az 600 °C CMC 0,11 °C Pt 385 (200 Ω) 600 °C az 630 °C CMC 0,12 °C Pt 385 (500 Ω) -200 °C az -80 °C CMC 0,03 °C Pt 385 (500 Ω) -80 °C az 100 °C CMC 0,04 °C Pt 385 (500 Ω) 100 °C az 260 °C CMC 0,05 °C Pt 385 (500 Ω) 260 °C az 400 °C CMC 0,06 °C Pt 385 (500 Ω) 400 °C az 600 °C CMC 0,07 °C Pt 385 (500 Ω) 600 °C az 630 °C CMC 0,09 °C Pt 385 (1000 Ω) -200 °C az 0 °C CMC 0,02 °C Pt 385 (1000 Ω) 0 °C az 100 °C CMC 0,03 °C Pt 385 (1000 Ω) 100 °C az 260 °C CMC 0,04 °C Pt 385 (1000 Ω) 260 °C az 600 °C CMC 0,05 °C Pt 385 (1000 Ω) 600 °C az 630 °C CMC 0,18 °C Ni 672 (120 Ω) -80 °C az 100 °C CMC 0,06 °C Ni 672 (120 Ω) 100 °C az 260 °C CMC 0,11 °C Cu 427 (10 Ω) -80 az 260 °C CMC 0,24 °C Cu 428 (50 Ω) -180 az 200 °C CMC 0,31 °C TC K -200 °C az -100 °C CMC 0,22 °C TC K -100 °C az -25 °C CMC 0,10 °C TC K -25 °C az 120 °C CMC 0,09 °C TC K 120 °C az 1000 °C CMC 0,16 °C TC K 1000 °C az 1372 °C CMC 0,27 °C TC J -210 °C az -100 °C CMC 0,19 °C TC J -100 °C az -30 °C CMC 0,10 °C TC J -30 °C az 150 °C CMC 0,09 °C TC J 150 °C az 760 °C CMC 0,11 °C TC J 760 °C az 1200 °C CMC 0,19 °C VKP01/05 VKP02/05","search_en":"Temperature - electrical simulation / multimeters and thermometers with connectable resistance temperature probes or thermocouples, installation testers and multifunction testers with connectable thermocouples, process calibrators Calibration – temperature Simulation of the sensor electrical input signal Pt 385 (100 Ω) -200 °C to -80 °C CMC 0,04 °C Pt 385 (100 Ω) -80 °C to 0 °C CMC 0,04 °C Pt 385 (100 Ω) 0 °C to 100 °C CMC 0,05 °C Pt 385 (100 Ω) 100 °C to 300 °C CMC 0,07 °C Pt 385 (100 Ω) 300 °C to 400 °C CMC 0,08 °C Pt 385 (100 Ω) 400 °C to 630 °C CMC 0,09 °C Pt 385 (100 Ω) 630 °C to 800 °C CMC 0,18 °C Pt 3926 (100 Ω) -200 °C to -80 °C CMC 0,04 °C Pt 3926 (100 Ω) -80 °C to 0 °C CMC 0,04 °C Pt 3926 (100 Ω) 0 °C to 100 °C CMC 0,05 °C Pt 3926 (100 Ω) 100 °C to 300 °C CMC 0,07 °C Pt 3926 (100 Ω) 300 °C to 400 °C CMC 0,08 °C Pt 3926 (100 Ω) 400 °C to 630 °C CMC 0,09 °C Pt 3916 (100 Ω) -200 °C to -190 °C CMC 0,19 °C Pt 3916 (100 Ω) -190 °C to -80 °C CMC 0,03 °C Pt 3916 (100 Ω) -80 °C to 0 °C CMC 0,04 °C Pt 3916 (100 Ω) 0 °C to 260 °C CMC 0,05 °C Pt 3916 (100 Ω) 260 °C to 300 °C CMC 0,06 °C Pt 3916 (100 Ω) 300 °C to 400 °C CMC 0,07 °C Pt 3916 (100 Ω) 400 °C to 600 °C CMC 0,08 °C Pt 3916 (100 Ω) 600 °C to 630 °C CMC 0,18 °C Pt 385 (200 Ω) -200 °C to 100 °C CMC 0,03 °C Pt 385 (200 Ω) 100 °C to 260 °C CMC 0,04 °C Pt 385 (200 Ω) 260 °C to 300 °C CMC 0,09 °C Pt 385 (200 Ω) 300 °C to 400 °C CMC 0,10 °C Pt 385 (200 Ω) 400 °C to 600 °C CMC 0,11 °C Pt 385 (200 Ω) 600 °C to 630 °C CMC 0,12 °C Pt 385 (500 Ω) -200 °C to -80 °C CMC 0,03 °C Pt 385 (500 Ω) -80 °C to 100 °C CMC 0,04 °C Pt 385 (500 Ω) 100 °C to 260 °C CMC 0,05 °C Pt 385 (500 Ω) 260 °C to 400 °C CMC 0,06 °C Pt 385 (500 Ω) 400 °C to 600 °C CMC 0,07 °C Pt 385 (500 Ω) 600 °C to 630 °C CMC 0,09 °C Pt 385 (1000 Ω) -200 °C to 0 °C CMC 0,02 °C Pt 385 (1000 Ω) 0 °C to 100 °C CMC 0,03 °C Pt 385 (1000 Ω) 100 °C to 260 °C CMC 0,04 °C Pt 385 (1000 Ω) 260 °C to 600 °C CMC 0,05 °C Pt 385 (1000 Ω) 600 °C to 630 °C CMC 0,18 °C Ni 672 (120 Ω) -80 °C to 100 °C CMC 0,06 °C Ni 672 (120 Ω) 100 °C to 260 °C CMC 0,11 °C Cu 427 (10 Ω) -80 to 260 °C CMC 0,24 °C Cu 428 (50 Ω) -180 to 200 °C CMC 0,31 °C TC K -200 °C to -100 °C CMC 0,22 °C TC K -100 °C to -25 °C CMC 0,10 °C TC K -25 °C to 120 °C CMC 0,09 °C TC K 120 °C to 1000 °C CMC 0,16 °C TC K 1000 °C to 1372 °C CMC 0,27 °C TC J -210 °C to -100 °C CMC 0,19 °C TC J -100 °C to -30 °C CMC 0,10 °C TC J -30 °C to 150 °C CMC 0,09 °C TC J 150 °C to 760 °C CMC 0,11 °C TC J 760 °C to 1200 °C CMC 0,19 °C VKP01/05 VKP02/05","search_zh":"温度 - 电模拟 / 可连接电阻温度探头或热电偶的万用表和温度计、可连接热电偶的电气安装测试仪和多功能测试仪、过程校准器 校准 – 温度 模拟传感器电输入信号 Pt 385 (100 Ω) -200 °C 至 -80 °C CMC 0,04 °C Pt 385 (100 Ω) -80 °C 至 0 °C CMC 0,04 °C Pt 385 (100 Ω) 0 °C 至 100 °C CMC 0,05 °C Pt 385 (100 Ω) 100 °C 至 300 °C CMC 0,07 °C Pt 385 (100 Ω) 300 °C 至 400 °C CMC 0,08 °C Pt 385 (100 Ω) 400 °C 至 630 °C CMC 0,09 °C Pt 385 (100 Ω) 630 °C 至 800 °C CMC 0,18 °C Pt 3926 (100 Ω) -200 °C 至 -80 °C CMC 0,04 °C Pt 3926 (100 Ω) -80 °C 至 0 °C CMC 0,04 °C Pt 3926 (100 Ω) 0 °C 至 100 °C CMC 0,05 °C Pt 3926 (100 Ω) 100 °C 至 300 °C CMC 0,07 °C Pt 3926 (100 Ω) 300 °C 至 400 °C CMC 0,08 °C Pt 3926 (100 Ω) 400 °C 至 630 °C CMC 0,09 °C Pt 3916 (100 Ω) -200 °C 至 -190 °C CMC 0,19 °C Pt 3916 (100 Ω) -190 °C 至 -80 °C CMC 0,03 °C Pt 3916 (100 Ω) -80 °C 至 0 °C CMC 0,04 °C Pt 3916 (100 Ω) 0 °C 至 260 °C CMC 0,05 °C Pt 3916 (100 Ω) 260 °C 至 300 °C CMC 0,06 °C Pt 3916 (100 Ω) 300 °C 至 400 °C CMC 0,07 °C Pt 3916 (100 Ω) 400 °C 至 600 °C CMC 0,08 °C Pt 3916 (100 Ω) 600 °C 至 630 °C CMC 0,18 °C Pt 385 (200 Ω) -200 °C 至 100 °C CMC 0,03 °C Pt 385 (200 Ω) 100 °C 至 260 °C CMC 0,04 °C Pt 385 (200 Ω) 260 °C 至 300 °C CMC 0,09 °C Pt 385 (200 Ω) 300 °C 至 400 °C CMC 0,10 °C Pt 385 (200 Ω) 400 °C 至 600 °C CMC 0,11 °C Pt 385 (200 Ω) 600 °C 至 630 °C CMC 0,12 °C Pt 385 (500 Ω) -200 °C 至 -80 °C CMC 0,03 °C Pt 385 (500 Ω) -80 °C 至 100 °C CMC 0,04 °C Pt 385 (500 Ω) 100 °C 至 260 °C CMC 0,05 °C Pt 385 (500 Ω) 260 °C 至 400 °C CMC 0,06 °C Pt 385 (500 Ω) 400 °C 至 600 °C CMC 0,07 °C Pt 385 (500 Ω) 600 °C 至 630 °C CMC 0,09 °C Pt 385 (1000 Ω) -200 °C 至 0 °C CMC 0,02 °C Pt 385 (1000 Ω) 0 °C 至 100 °C CMC 0,03 °C Pt 385 (1000 Ω) 100 °C 至 260 °C CMC 0,04 °C Pt 385 (1000 Ω) 260 °C 至 600 °C CMC 0,05 °C Pt 385 (1000 Ω) 600 °C 至 630 °C CMC 0,18 °C Ni 672 (120 Ω) -80 °C 至 100 °C CMC 0,06 °C Ni 672 (120 Ω) 100 °C 至 260 °C CMC 0,11 °C Cu 427 (10 Ω) -80 至 260 °C CMC 0,24 °C Cu 428 (50 Ω) -180 至 200 °C CMC 0,31 °C K 型热电偶 -200 °C 至 -100 °C CMC 0,22 °C K 型热电偶 -100 °C 至 -25 °C CMC 0,10 °C K 型热电偶 -25 °C 至 120 °C CMC 0,09 °C K 型热电偶 120 °C 至 1000 °C CMC 0,16 °C K 型热电偶 1000 °C 至 1372 °C CMC 0,27 °C J 型热电偶 -210 °C 至 -100 °C CMC 0,19 °C J 型热电偶 -100 °C 至 -30 °C CMC 0,10 °C J 型热电偶 -30 °C 至 150 °C CMC 0,09 °C J 型热电偶 150 °C 至 760 °C CMC 0,11 °C J 型热电偶 760 °C 至 1200 °C CMC 0,19 °C VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"81aa394eee426fb64265355a","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"2","test_object":"Temperatura - symulacja elektryczna / symulatory i źródła rezystancji odpowiadającej temperaturze rezystancyjnej sondy temperatury, symulatory i źródła napięcia stałego odpowiadającego temperaturze termopary, kalibratory procesowe","test_object_en":"Temperature - electrical simulation / simulators and sources of DC resistance equivalent to the temperature of a resistance temperature probe, simulators and sources of DC voltage equivalent to the thermocouple temperature, process calibrators","test_object_zh":"温度 - 电模拟 / 等效于电阻温度探头温度的直流电阻模拟器和源、等效于热电偶温度的直流电压模拟器和源、过程校准器","test_object_cs":"Teplota - elektrická simulace / simulátory a zdroje stejnosměrného odporu ekvivalentního teplotě odporové teplotní sondy, simulátory a zdroje stejnosměrného napětí ekvivalentního teplotě termočlánku, procesní kalibrátory","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Pt 385 (100 Ω)","range":"od -200 °C do -80 °C","cmc":"0,031 °C"},{"name":"Pt 385 (100 Ω)","range":"od -80 °C do 100 °C","cmc":"0,020 °C"},{"name":"Pt 385 (100 Ω)","range":"od 100 °C do 300 °C","cmc":"0,030 °C"},{"name":"Pt 385 (100 Ω)","range":"od 300 °C do 400 °C","cmc":"0,035 °C"},{"name":"Pt 385 (100 Ω)","range":"od 400 °C do 630 °C","cmc":"0,047 °C"},{"name":"Pt 385 (100 Ω)","range":"od 630 °C do 800 °C","cmc":"0,057 °C"},{"name":"Pt 3926 (100 Ω)","range":"od -200 °C do -80 °C","cmc":"0,031 °C"},{"name":"Pt 3926 (100 Ω)","range":"od -80 °C do 0 °C","cmc":"0,015 °C"},{"name":"Pt 3926 (100 Ω)","range":"od 0 °C do 100 °C","cmc":"0,019 °C"},{"name":"Pt 3926 (100 Ω)","range":"od 100 °C do 300 °C","cmc":"0,029 °C"},{"name":"Pt 3926 (100 Ω)","range":"od 300 °C do 400 °C","cmc":"0,034 °C"},{"name":"Pt 3926 (100 Ω)","range":"od 400 °C do 630 °C","cmc":"0,046 °C"},{"name":"Pt 3916 (100 Ω)","range":"od -200 °C do -190 °C","cmc":"0,028 °C"},{"name":"Pt 3916 (100 Ω)","range":"od -190 °C do -80 °C","cmc":"0,012 °C"},{"name":"Pt 3916 (100 Ω)","range":"od -80 °C do 0 °C","cmc":"0,015 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 0 °C do 100 °C","cmc":"0,019 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 100 °C do 260 °C","cmc":"0,028 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 260 °C do 300 °C","cmc":"0,029 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 300 °C do 400 °C","cmc":"0,034 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 400 °C do 600 °C","cmc":"0,045 °C"},{"name":"Pt 3916 (100 Ω)","range":"od 600 °C do 630 °C","cmc":"0,047 °C"},{"name":"Pt 385 (200 Ω)","range":"od -200 °C do -80 °C","cmc":"0,072 °C"},{"name":"Pt 385 (200 Ω)","range":"od -80 °C do 0 °C","cmc":"0,076 °C"},{"name":"Pt 385 (200 Ω)","range":"od 0 °C do 100 °C","cmc":"0,079 °C"},{"name":"Pt 385 (200 Ω)","range":"od 100 °C do 260 °C","cmc":"0,082 °C"},{"name":"Pt 385 (200 Ω)","range":"od 260 °C do 300 °C","cmc":"0,090 °C"},{"name":"Pt 385 (200 Ω)","range":"od 300 °C do 400 °C","cmc":"0,093 °C"},{"name":"Pt 385 (200 Ω)","range":"od 400 °C do 600 °C","cmc":"0,10 °C"},{"name":"Pt 385 (200 Ω)","range":"od 600 °C do 630 °C","cmc":"0,10 °C"},{"name":"Pt 385 (500 Ω)","range":"od -200 °C do -80 °C","cmc":"0,047 °C"},{"name":"Pt 385 (500 Ω)","range":"od -80 °C do 0 °C","cmc":"0,050 °C"},{"name":"Pt 385 (500 Ω)","range":"od 0 °C do 100 °C","cmc":"0,045 °C"},{"name":"Pt 385 (500 Ω)","range":"od 100 °C do 260 °C","cmc":"0,033 °C"},{"name":"Pt 385 (500 Ω)","range":"od 260 °C do 300 °C","cmc":"0,035 °C"},{"name":"Pt 385 (500 Ω)","range":"od 300 °C do 400 °C","cmc":"0,041 °C"},{"name":"Pt 385 (500 Ω)","range":"od 400 °C do 600 °C","cmc":"0,052 °C"},{"name":"Pt 385 (500 Ω)","range":"od 600 °C do 630 °C","cmc":"0,076 °C"},{"name":"Pt 385 (1000 Ω)","range":"od -200 °C do -80 °C","cmc":"0,032 °C"},{"name":"Pt 385 (1000 Ω)","range":"od -80 °C do 0 °C","cmc":"0,035 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 0 °C do 100 °C","cmc":"0,040 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 100 °C do 260 °C","cmc":"0,028 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 260 °C do 300 °C","cmc":"0,030 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 300 °C do 400 °C","cmc":"0,034 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 400 °C do 600 °C","cmc":"0,045 °C"},{"name":"Pt 385 (1000 Ω)","range":"od 600 °C do 630 °C","cmc":"0,047 °C"},{"name":"PtNi 385 (120 Ω)","range":"od -80 °C do 0 °C","cmc":"0,21 °C"},{"name":"PtNi 385 (120 Ω)","range":"od 0 °C do 100 °C","cmc":"0,21 °C"},{"name":"PtNi 385 (120 Ω)","range":"od 100 °C do 260 °C","cmc":"0,21 °C"},{"name":"TC K","range":"od -200 °C do -100 °C","cmc":"0,22 °C"},{"name":"TC K","range":"od -100 °C do -25 °C","cmc":"0,10 °C"},{"name":"TC K","range":"od -25 °C do 120 °C","cmc":"0,09 °C"},{"name":"TC K","range":"od 120 °C do 1000 °C","cmc":"0,16 °C"},{"name":"TC K","range":"od 1000 °C do 1372 °C","cmc":"0,27 °C"},{"name":"TC J","range":"od -210 °C do -100 °C","cmc":"0,19 °C"},{"name":"TC J","range":"od -100 °C do -30 °C","cmc":"0,10 °C"},{"name":"TC J","range":"od -30 °C do 150 °C","cmc":"0,09 °C"},{"name":"TC J","range":"od 150 °C do 760 °C","cmc":"0,11 °C"},{"name":"TC J","range":"od 760 °C do 1200 °C","cmc":"0,19 °C"}],"parameters_en":[{"name":"Pt 385 (100 Ω)","range":"-200 °C to -80 °C","cmc":"0,031 °C"},{"name":"Pt 385 (100 Ω)","range":"-80 °C to 100 °C","cmc":"0,020 °C"},{"name":"Pt 385 (100 Ω)","range":"100 °C to 300 °C","cmc":"0,030 °C"},{"name":"Pt 385 (100 Ω)","range":"300 °C to 400 °C","cmc":"0,035 °C"},{"name":"Pt 385 (100 Ω)","range":"400 °C to 630 °C","cmc":"0,047 °C"},{"name":"Pt 385 (100 Ω)","range":"630 °C to 800 °C","cmc":"0,057 °C"},{"name":"Pt 3926 (100 Ω)","range":"-200 °C to -80 °C","cmc":"0,031 °C"},{"name":"Pt 3926 (100 Ω)","range":"-80 °C to 0 °C","cmc":"0,015 °C"},{"name":"Pt 3926 (100 Ω)","range":"0 °C to 100 °C","cmc":"0,019 °C"},{"name":"Pt 3926 (100 Ω)","range":"100 °C to 300 °C","cmc":"0,029 °C"},{"name":"Pt 3926 (100 Ω)","range":"300 °C to 400 °C","cmc":"0,034 °C"},{"name":"Pt 3926 (100 Ω)","range":"400 °C to 630 °C","cmc":"0,046 °C"},{"name":"Pt 3916 (100 Ω)","range":"-200 °C to -190 °C","cmc":"0,028 °C"},{"name":"Pt 3916 (100 Ω)","range":"-190 °C to -80 °C","cmc":"0,012 °C"},{"name":"Pt 3916 (100 Ω)","range":"-80 °C to 0 °C","cmc":"0,015 °C"},{"name":"Pt 3916 (100 Ω)","range":"0 °C to 100 °C","cmc":"0,019 °C"},{"name":"Pt 3916 (100 Ω)","range":"100 °C to 260 °C","cmc":"0,028 °C"},{"name":"Pt 3916 (100 Ω)","range":"260 °C to 300 °C","cmc":"0,029 °C"},{"name":"Pt 3916 (100 Ω)","range":"300 °C to 400 °C","cmc":"0,034 °C"},{"name":"Pt 3916 (100 Ω)","range":"400 °C to 600 °C","cmc":"0,045 °C"},{"name":"Pt 3916 (100 Ω)","range":"600 °C to 630 °C","cmc":"0,047 °C"},{"name":"Pt 385 (200 Ω)","range":"-200 °C to -80 °C","cmc":"0,072 °C"},{"name":"Pt 385 (200 Ω)","range":"-80 °C to 0 °C","cmc":"0,076 °C"},{"name":"Pt 385 (200 Ω)","range":"0 °C to 100 °C","cmc":"0,079 °C"},{"name":"Pt 385 (200 Ω)","range":"100 °C to 260 °C","cmc":"0,082 °C"},{"name":"Pt 385 (200 Ω)","range":"260 °C to 300 °C","cmc":"0,090 °C"},{"name":"Pt 385 (200 Ω)","range":"300 °C to 400 °C","cmc":"0,093 °C"},{"name":"Pt 385 (200 Ω)","range":"400 °C to 600 °C","cmc":"0,10 °C"},{"name":"Pt 385 (200 Ω)","range":"600 °C to 630 °C","cmc":"0,10 °C"},{"name":"Pt 385 (500 Ω)","range":"-200 °C to -80 °C","cmc":"0,047 °C"},{"name":"Pt 385 (500 Ω)","range":"-80 °C to 0 °C","cmc":"0,050 °C"},{"name":"Pt 385 (500 Ω)","range":"0 °C to 100 °C","cmc":"0,045 °C"},{"name":"Pt 385 (500 Ω)","range":"100 °C to 260 °C","cmc":"0,033 °C"},{"name":"Pt 385 (500 Ω)","range":"260 °C to 300 °C","cmc":"0,035 °C"},{"name":"Pt 385 (500 Ω)","range":"300 °C to 400 °C","cmc":"0,041 °C"},{"name":"Pt 385 (500 Ω)","range":"400 °C to 600 °C","cmc":"0,052 °C"},{"name":"Pt 385 (500 Ω)","range":"600 °C to 630 °C","cmc":"0,076 °C"},{"name":"Pt 385 (1000 Ω)","range":"-200 °C to -80 °C","cmc":"0,032 °C"},{"name":"Pt 385 (1000 Ω)","range":"-80 °C to 0 °C","cmc":"0,035 °C"},{"name":"Pt 385 (1000 Ω)","range":"0 °C to 100 °C","cmc":"0,040 °C"},{"name":"Pt 385 (1000 Ω)","range":"100 °C to 260 °C","cmc":"0,028 °C"},{"name":"Pt 385 (1000 Ω)","range":"260 °C to 300 °C","cmc":"0,030 °C"},{"name":"Pt 385 (1000 Ω)","range":"300 °C to 400 °C","cmc":"0,034 °C"},{"name":"Pt 385 (1000 Ω)","range":"400 °C to 600 °C","cmc":"0,045 °C"},{"name":"Pt 385 (1000 Ω)","range":"600 °C to 630 °C","cmc":"0,047 °C"},{"name":"PtNi 385 (120 Ω)","range":"-80 °C to 0 °C","cmc":"0,21 °C"},{"name":"PtNi 385 (120 Ω)","range":"0 °C to 100 °C","cmc":"0,21 °C"},{"name":"PtNi 385 (120 Ω)","range":"100 °C to 260 °C","cmc":"0,21 °C"},{"name":"TC K","range":"-200 °C to -100 °C","cmc":"0,22 °C"},{"name":"TC K","range":"-100 °C to -25 °C","cmc":"0,10 °C"},{"name":"TC K","range":"-25 °C to 120 °C","cmc":"0,09 °C"},{"name":"TC K","range":"120 °C to 1000 °C","cmc":"0,16 °C"},{"name":"TC K","range":"1000 °C to 1372 °C","cmc":"0,27 °C"},{"name":"TC J","range":"-210 °C to -100 °C","cmc":"0,19 °C"},{"name":"TC J","range":"-100 °C to -30 °C","cmc":"0,10 °C"},{"name":"TC J","range":"-30 °C to 150 °C","cmc":"0,09 °C"},{"name":"TC J","range":"150 °C to 760 °C","cmc":"0,11 °C"},{"name":"TC J","range":"760 °C to 1200 °C","cmc":"0,19 °C"}],"parameters_zh":[{"name":"Pt 385 (100 Ω)","range":"-200 °C 至 -80 °C","cmc":"0,031 °C"},{"name":"Pt 385 (100 Ω)","range":"-80 °C 至 100 °C","cmc":"0,020 °C"},{"name":"Pt 385 (100 Ω)","range":"100 °C 至 300 °C","cmc":"0,030 °C"},{"name":"Pt 385 (100 Ω)","range":"300 °C 至 400 °C","cmc":"0,035 °C"},{"name":"Pt 385 (100 Ω)","range":"400 °C 至 630 °C","cmc":"0,047 °C"},{"name":"Pt 385 (100 Ω)","range":"630 °C 至 800 °C","cmc":"0,057 °C"},{"name":"Pt 3926 (100 Ω)","range":"-200 °C 至 -80 °C","cmc":"0,031 °C"},{"name":"Pt 3926 (100 Ω)","range":"-80 °C 至 0 °C","cmc":"0,015 °C"},{"name":"Pt 3926 (100 Ω)","range":"0 °C 至 100 °C","cmc":"0,019 °C"},{"name":"Pt 3926 (100 Ω)","range":"100 °C 至 300 °C","cmc":"0,029 °C"},{"name":"Pt 3926 (100 Ω)","range":"300 °C 至 400 °C","cmc":"0,034 °C"},{"name":"Pt 3926 (100 Ω)","range":"400 °C 至 630 °C","cmc":"0,046 °C"},{"name":"Pt 3916 (100 Ω)","range":"-200 °C 至 -190 °C","cmc":"0,028 °C"},{"name":"Pt 3916 (100 Ω)","range":"-190 °C 至 -80 °C","cmc":"0,012 °C"},{"name":"Pt 3916 (100 Ω)","range":"-80 °C 至 0 °C","cmc":"0,015 °C"},{"name":"Pt 3916 (100 Ω)","range":"0 °C 至 100 °C","cmc":"0,019 °C"},{"name":"Pt 3916 (100 Ω)","range":"100 °C 至 260 °C","cmc":"0,028 °C"},{"name":"Pt 3916 (100 Ω)","range":"260 °C 至 300 °C","cmc":"0,029 °C"},{"name":"Pt 3916 (100 Ω)","range":"300 °C 至 400 °C","cmc":"0,034 °C"},{"name":"Pt 3916 (100 Ω)","range":"400 °C 至 600 °C","cmc":"0,045 °C"},{"name":"Pt 3916 (100 Ω)","range":"600 °C 至 630 °C","cmc":"0,047 °C"},{"name":"Pt 385 (200 Ω)","range":"-200 °C 至 -80 °C","cmc":"0,072 °C"},{"name":"Pt 385 (200 Ω)","range":"-80 °C 至 0 °C","cmc":"0,076 °C"},{"name":"Pt 385 (200 Ω)","range":"0 °C 至 100 °C","cmc":"0,079 °C"},{"name":"Pt 385 (200 Ω)","range":"100 °C 至 260 °C","cmc":"0,082 °C"},{"name":"Pt 385 (200 Ω)","range":"260 °C 至 300 °C","cmc":"0,090 °C"},{"name":"Pt 385 (200 Ω)","range":"300 °C 至 400 °C","cmc":"0,093 °C"},{"name":"Pt 385 (200 Ω)","range":"400 °C 至 600 °C","cmc":"0,10 °C"},{"name":"Pt 385 (200 Ω)","range":"600 °C 至 630 °C","cmc":"0,10 °C"},{"name":"Pt 385 (500 Ω)","range":"-200 °C 至 -80 °C","cmc":"0,047 °C"},{"name":"Pt 385 (500 Ω)","range":"-80 °C 至 0 °C","cmc":"0,050 °C"},{"name":"Pt 385 (500 Ω)","range":"0 °C 至 100 °C","cmc":"0,045 °C"},{"name":"Pt 385 (500 Ω)","range":"100 °C 至 260 °C","cmc":"0,033 °C"},{"name":"Pt 385 (500 Ω)","range":"260 °C 至 300 °C","cmc":"0,035 °C"},{"name":"Pt 385 (500 Ω)","range":"300 °C 至 400 °C","cmc":"0,041 °C"},{"name":"Pt 385 (500 Ω)","range":"400 °C 至 600 °C","cmc":"0,052 °C"},{"name":"Pt 385 (500 Ω)","range":"600 °C 至 630 °C","cmc":"0,076 °C"},{"name":"Pt 385 (1000 Ω)","range":"-200 °C 至 -80 °C","cmc":"0,032 °C"},{"name":"Pt 385 (1000 Ω)","range":"-80 °C 至 0 °C","cmc":"0,035 °C"},{"name":"Pt 385 (1000 Ω)","range":"0 °C 至 100 °C","cmc":"0,040 °C"},{"name":"Pt 385 (1000 Ω)","range":"100 °C 至 260 °C","cmc":"0,028 °C"},{"name":"Pt 385 (1000 Ω)","range":"260 °C 至 300 °C","cmc":"0,030 °C"},{"name":"Pt 385 (1000 Ω)","range":"300 °C 至 400 °C","cmc":"0,034 °C"},{"name":"Pt 385 (1000 Ω)","range":"400 °C 至 600 °C","cmc":"0,045 °C"},{"name":"Pt 385 (1000 Ω)","range":"600 °C 至 630 °C","cmc":"0,047 °C"},{"name":"PtNi 385 (120 Ω)","range":"-80 °C 至 0 °C","cmc":"0,21 °C"},{"name":"PtNi 385 (120 Ω)","range":"0 °C 至 100 °C","cmc":"0,21 °C"},{"name":"PtNi 385 (120 Ω)","range":"100 °C 至 260 °C","cmc":"0,21 °C"},{"name":"K 型热电偶","range":"-200 °C 至 -100 °C","cmc":"0,22 °C"},{"name":"K 型热电偶","range":"-100 °C 至 -25 °C","cmc":"0,10 °C"},{"name":"K 型热电偶","range":"-25 °C 至 120 °C","cmc":"0,09 °C"},{"name":"K 型热电偶","range":"120 °C 至 1000 °C","cmc":"0,16 °C"},{"name":"K 型热电偶","range":"1000 °C 至 1372 °C","cmc":"0,27 °C"},{"name":"J 型热电偶","range":"-210 °C 至 -100 °C","cmc":"0,19 °C"},{"name":"J 型热电偶","range":"-100 °C 至 -30 °C","cmc":"0,10 °C"},{"name":"J 型热电偶","range":"-30 °C 至 150 °C","cmc":"0,09 °C"},{"name":"J 型热电偶","range":"150 °C 至 760 °C","cmc":"0,11 °C"},{"name":"J 型热电偶","range":"760 °C 至 1200 °C","cmc":"0,19 °C"}],"parameters_cs":[{"name":"Pt 385 (100 Ω)","range":"-200 °C až -80 °C","cmc":"0,031 °C"},{"name":"Pt 385 (100 Ω)","range":"-80 °C až 100 °C","cmc":"0,020 °C"},{"name":"Pt 385 (100 Ω)","range":"100 °C až 300 °C","cmc":"0,030 °C"},{"name":"Pt 385 (100 Ω)","range":"300 °C až 400 °C","cmc":"0,035 °C"},{"name":"Pt 385 (100 Ω)","range":"400 °C až 630 °C","cmc":"0,047 °C"},{"name":"Pt 385 (100 Ω)","range":"630 °C až 800 °C","cmc":"0,057 °C"},{"name":"Pt 3926 (100 Ω)","range":"-200 °C až -80 °C","cmc":"0,031 °C"},{"name":"Pt 3926 (100 Ω)","range":"-80 °C až 0 °C","cmc":"0,015 °C"},{"name":"Pt 3926 (100 Ω)","range":"0 °C až 100 °C","cmc":"0,019 °C"},{"name":"Pt 3926 (100 Ω)","range":"100 °C až 300 °C","cmc":"0,029 °C"},{"name":"Pt 3926 (100 Ω)","range":"300 °C až 400 °C","cmc":"0,034 °C"},{"name":"Pt 3926 (100 Ω)","range":"400 °C až 630 °C","cmc":"0,046 °C"},{"name":"Pt 3916 (100 Ω)","range":"-200 °C až -190 °C","cmc":"0,028 °C"},{"name":"Pt 3916 (100 Ω)","range":"-190 °C až -80 °C","cmc":"0,012 °C"},{"name":"Pt 3916 (100 Ω)","range":"-80 °C až 0 °C","cmc":"0,015 °C"},{"name":"Pt 3916 (100 Ω)","range":"0 °C až 100 °C","cmc":"0,019 °C"},{"name":"Pt 3916 (100 Ω)","range":"100 °C až 260 °C","cmc":"0,028 °C"},{"name":"Pt 3916 (100 Ω)","range":"260 °C až 300 °C","cmc":"0,029 °C"},{"name":"Pt 3916 (100 Ω)","range":"300 °C až 400 °C","cmc":"0,034 °C"},{"name":"Pt 3916 (100 Ω)","range":"400 °C až 600 °C","cmc":"0,045 °C"},{"name":"Pt 3916 (100 Ω)","range":"600 °C až 630 °C","cmc":"0,047 °C"},{"name":"Pt 385 (200 Ω)","range":"-200 °C až -80 °C","cmc":"0,072 °C"},{"name":"Pt 385 (200 Ω)","range":"-80 °C až 0 °C","cmc":"0,076 °C"},{"name":"Pt 385 (200 Ω)","range":"0 °C až 100 °C","cmc":"0,079 °C"},{"name":"Pt 385 (200 Ω)","range":"100 °C až 260 °C","cmc":"0,082 °C"},{"name":"Pt 385 (200 Ω)","range":"260 °C až 300 °C","cmc":"0,090 °C"},{"name":"Pt 385 (200 Ω)","range":"300 °C až 400 °C","cmc":"0,093 °C"},{"name":"Pt 385 (200 Ω)","range":"400 °C až 600 °C","cmc":"0,10 °C"},{"name":"Pt 385 (200 Ω)","range":"600 °C až 630 °C","cmc":"0,10 °C"},{"name":"Pt 385 (500 Ω)","range":"-200 °C až -80 °C","cmc":"0,047 °C"},{"name":"Pt 385 (500 Ω)","range":"-80 °C až 0 °C","cmc":"0,050 °C"},{"name":"Pt 385 (500 Ω)","range":"0 °C až 100 °C","cmc":"0,045 °C"},{"name":"Pt 385 (500 Ω)","range":"100 °C až 260 °C","cmc":"0,033 °C"},{"name":"Pt 385 (500 Ω)","range":"260 °C až 300 °C","cmc":"0,035 °C"},{"name":"Pt 385 (500 Ω)","range":"300 °C až 400 °C","cmc":"0,041 °C"},{"name":"Pt 385 (500 Ω)","range":"400 °C až 600 °C","cmc":"0,052 °C"},{"name":"Pt 385 (500 Ω)","range":"600 °C až 630 °C","cmc":"0,076 °C"},{"name":"Pt 385 (1000 Ω)","range":"-200 °C až -80 °C","cmc":"0,032 °C"},{"name":"Pt 385 (1000 Ω)","range":"-80 °C až 0 °C","cmc":"0,035 °C"},{"name":"Pt 385 (1000 Ω)","range":"0 °C až 100 °C","cmc":"0,040 °C"},{"name":"Pt 385 (1000 Ω)","range":"100 °C až 260 °C","cmc":"0,028 °C"},{"name":"Pt 385 (1000 Ω)","range":"260 °C až 300 °C","cmc":"0,030 °C"},{"name":"Pt 385 (1000 Ω)","range":"300 °C až 400 °C","cmc":"0,034 °C"},{"name":"Pt 385 (1000 Ω)","range":"400 °C až 600 °C","cmc":"0,045 °C"},{"name":"Pt 385 (1000 Ω)","range":"600 °C až 630 °C","cmc":"0,047 °C"},{"name":"PtNi 385 (120 Ω)","range":"-80 °C až 0 °C","cmc":"0,21 °C"},{"name":"PtNi 385 (120 Ω)","range":"0 °C až 100 °C","cmc":"0,21 °C"},{"name":"PtNi 385 (120 Ω)","range":"100 °C až 260 °C","cmc":"0,21 °C"},{"name":"TC K","range":"-200 °C až -100 °C","cmc":"0,22 °C"},{"name":"TC K","range":"-100 °C až -25 °C","cmc":"0,10 °C"},{"name":"TC K","range":"-25 °C až 120 °C","cmc":"0,09 °C"},{"name":"TC K","range":"120 °C až 1000 °C","cmc":"0,16 °C"},{"name":"TC K","range":"1000 °C až 1372 °C","cmc":"0,27 °C"},{"name":"TC J","range":"-210 °C až -100 °C","cmc":"0,19 °C"},{"name":"TC J","range":"-100 °C až -30 °C","cmc":"0,10 °C"},{"name":"TC J","range":"-30 °C až 150 °C","cmc":"0,09 °C"},{"name":"TC J","range":"150 °C až 760 °C","cmc":"0,11 °C"},{"name":"TC J","range":"760 °C až 1200 °C","cmc":"0,19 °C"}],"technique":"Pomiar multimetrem z przeliczeniem z wyjściowego sygnału elektrycznego","technique_en":"Measurement by a multimeter with conversion from the output electrical signal","technique_zh":"用万用表测量并由输出电信号换算","technique_cs":"Měření multimetrem přepočtem z výstupního elektrického signálu","techniques":["Pomiar multimetrem z przeliczeniem z wyjściowego sygnału elektrycznego"],"techniques_en":["Measurement by a multimeter with conversion from the output electrical signal"],"techniques_zh":["用万用表测量并由输出电信号换算"],"techniques_cs":["Měření multimetrem přepočtem z výstupního elektrického signálu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nPt 385 (100 Ω) od -200 °C do -80 °C CMC 0,031 °C\nPt 385 (100 Ω) od -80 °C do 100 °C CMC 0,020 °C\nPt 385 (100 Ω) od 100 °C do 300 °C CMC 0,030 °C\nPt 385 (100 Ω) od 300 °C do 400 °C CMC 0,035 °C\nPt 385 (100 Ω) od 400 °C do 630 °C CMC 0,047 °C\nPt 385 (100 Ω) od 630 °C do 800 °C CMC 0,057 °C\nPt 3926 (100 Ω) od -200 °C do -80 °C CMC 0,031 °C\nPt 3926 (100 Ω) od -80 °C do 0 °C CMC 0,015 °C\nPt 3926 (100 Ω) od 0 °C do 100 °C CMC 0,019 °C\nPt 3926 (100 Ω) od 100 °C do 300 °C CMC 0,029 °C\nPt 3926 (100 Ω) od 300 °C do 400 °C CMC 0,034 °C\nPt 3926 (100 Ω) od 400 °C do 630 °C CMC 0,046 °C\nPt 3916 (100 Ω) od -200 °C do -190 °C CMC 0,028 °C\nPt 3916 (100 Ω) od -190 °C do -80 °C CMC 0,012 °C\nPt 3916 (100 Ω) od -80 °C do 0 °C CMC 0,015 °C\nPt 3916 (100 Ω) od 0 °C do 100 °C CMC 0,019 °C\nPt 3916 (100 Ω) od 100 °C do 260 °C CMC 0,028 °C\nPt 3916 (100 Ω) od 260 °C do 300 °C CMC 0,029 °C\nPt 3916 (100 Ω) od 300 °C do 400 °C CMC 0,034 °C\nPt 3916 (100 Ω) od 400 °C do 600 °C CMC 0,045 °C\nPt 3916 (100 Ω) od 600 °C do 630 °C CMC 0,047 °C\nPt 385 (200 Ω) od -200 °C do -80 °C CMC 0,072 °C\nPt 385 (200 Ω) od -80 °C do 0 °C CMC 0,076 °C\nPt 385 (200 Ω) od 0 °C do 100 °C CMC 0,079 °C\nPt 385 (200 Ω) od 100 °C do 260 °C CMC 0,082 °C\nPt 385 (200 Ω) od 260 °C do 300 °C CMC 0,090 °C\nPt 385 (200 Ω) od 300 °C do 400 °C CMC 0,093 °C\nPt 385 (200 Ω) od 400 °C do 600 °C CMC 0,10 °C\nPt 385 (200 Ω) od 600 °C do 630 °C CMC 0,10 °C\nPt 385 (500 Ω) od -200 °C do -80 °C CMC 0,047 °C\nPt 385 (500 Ω) od -80 °C do 0 °C CMC 0,050 °C\nPt 385 (500 Ω) od 0 °C do 100 °C CMC 0,045 °C\nPt 385 (500 Ω) od 100 °C do 260 °C CMC 0,033 °C\nPt 385 (500 Ω) od 260 °C do 300 °C CMC 0,035 °C\nPt 385 (500 Ω) od 300 °C do 400 °C CMC 0,041 °C\nPt 385 (500 Ω) od 400 °C do 600 °C CMC 0,052 °C\nPt 385 (500 Ω) od 600 °C do 630 °C CMC 0,076 °C\nPt 385 (1000 Ω) od -200 °C do -80 °C CMC 0,032 °C\nPt 385 (1000 Ω) od -80 °C do 0 °C CMC 0,035 °C\nPt 385 (1000 Ω) od 0 °C do 100 °C CMC 0,040 °C\nPt 385 (1000 Ω) od 100 °C do 260 °C CMC 0,028 °C\nPt 385 (1000 Ω) od 260 °C do 300 °C CMC 0,030 °C\nPt 385 (1000 Ω) od 300 °C do 400 °C CMC 0,034 °C\nPt 385 (1000 Ω) od 400 °C do 600 °C CMC 0,045 °C\nPt 385 (1000 Ω) od 600 °C do 630 °C CMC 0,047 °C\nPtNi 385 (120 Ω) od -80 °C do 0 °C CMC 0,21 °C\nPtNi 385 (120 Ω) od 0 °C do 100 °C CMC 0,21 °C\nPtNi 385 (120 Ω) od 100 °C do 260 °C CMC 0,21 °C\nTC K od -200 °C do -100 °C CMC 0,22 °C\nTC K od -100 °C do -25 °C CMC 0,10 °C\nTC K od -25 °C do 120 °C CMC 0,09 °C\nTC K od 120 °C do 1000 °C CMC 0,16 °C\nTC K od 1000 °C do 1372 °C CMC 0,27 °C\nTC J od -210 °C do -100 °C CMC 0,19 °C\nTC J od -100 °C do -30 °C CMC 0,10 °C\nTC J od -30 °C do 150 °C CMC 0,09 °C\nTC J od 150 °C do 760 °C CMC 0,11 °C\nTC J od 760 °C do 1200 °C CMC 0,19 °C\nPomiar multimetrem z przeliczeniem z wyjściowego sygnału elektrycznego","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Temperatura - symulacja elektryczna / symulatory i źródła rezystancji odpowiadającej temperaturze rezystancyjnej sondy temperatury, symulatory i źródła napięcia stałego odpowiadającego temperaturze termopary, kalibratory procesowe Wzorcowanie – temperatura Pomiar multimetrem z przeliczeniem z wyjściowego sygnału elektrycznego Pt 385 (100 Ω) od -200 °C do -80 °C CMC 0,031 °C Pt 385 (100 Ω) od -80 °C do 100 °C CMC 0,020 °C Pt 385 (100 Ω) od 100 °C do 300 °C CMC 0,030 °C Pt 385 (100 Ω) od 300 °C do 400 °C CMC 0,035 °C Pt 385 (100 Ω) od 400 °C do 630 °C CMC 0,047 °C Pt 385 (100 Ω) od 630 °C do 800 °C CMC 0,057 °C Pt 3926 (100 Ω) od -200 °C do -80 °C CMC 0,031 °C Pt 3926 (100 Ω) od -80 °C do 0 °C CMC 0,015 °C Pt 3926 (100 Ω) od 0 °C do 100 °C CMC 0,019 °C Pt 3926 (100 Ω) od 100 °C do 300 °C CMC 0,029 °C Pt 3926 (100 Ω) od 300 °C do 400 °C CMC 0,034 °C Pt 3926 (100 Ω) od 400 °C do 630 °C CMC 0,046 °C Pt 3916 (100 Ω) od -200 °C do -190 °C CMC 0,028 °C Pt 3916 (100 Ω) od -190 °C do -80 °C CMC 0,012 °C Pt 3916 (100 Ω) od -80 °C do 0 °C CMC 0,015 °C Pt 3916 (100 Ω) od 0 °C do 100 °C CMC 0,019 °C Pt 3916 (100 Ω) od 100 °C do 260 °C CMC 0,028 °C Pt 3916 (100 Ω) od 260 °C do 300 °C CMC 0,029 °C Pt 3916 (100 Ω) od 300 °C do 400 °C CMC 0,034 °C Pt 3916 (100 Ω) od 400 °C do 600 °C CMC 0,045 °C Pt 3916 (100 Ω) od 600 °C do 630 °C CMC 0,047 °C Pt 385 (200 Ω) od -200 °C do -80 °C CMC 0,072 °C Pt 385 (200 Ω) od -80 °C do 0 °C CMC 0,076 °C Pt 385 (200 Ω) od 0 °C do 100 °C CMC 0,079 °C Pt 385 (200 Ω) od 100 °C do 260 °C CMC 0,082 °C Pt 385 (200 Ω) od 260 °C do 300 °C CMC 0,090 °C Pt 385 (200 Ω) od 300 °C do 400 °C CMC 0,093 °C Pt 385 (200 Ω) od 400 °C do 600 °C CMC 0,10 °C Pt 385 (200 Ω) od 600 °C do 630 °C CMC 0,10 °C Pt 385 (500 Ω) od -200 °C do -80 °C CMC 0,047 °C Pt 385 (500 Ω) od -80 °C do 0 °C CMC 0,050 °C Pt 385 (500 Ω) od 0 °C do 100 °C CMC 0,045 °C Pt 385 (500 Ω) od 100 °C do 260 °C CMC 0,033 °C Pt 385 (500 Ω) od 260 °C do 300 °C CMC 0,035 °C Pt 385 (500 Ω) od 300 °C do 400 °C CMC 0,041 °C Pt 385 (500 Ω) od 400 °C do 600 °C CMC 0,052 °C Pt 385 (500 Ω) od 600 °C do 630 °C CMC 0,076 °C Pt 385 (1000 Ω) od -200 °C do -80 °C CMC 0,032 °C Pt 385 (1000 Ω) od -80 °C do 0 °C CMC 0,035 °C Pt 385 (1000 Ω) od 0 °C do 100 °C CMC 0,040 °C Pt 385 (1000 Ω) od 100 °C do 260 °C CMC 0,028 °C Pt 385 (1000 Ω) od 260 °C do 300 °C CMC 0,030 °C Pt 385 (1000 Ω) od 300 °C do 400 °C CMC 0,034 °C Pt 385 (1000 Ω) od 400 °C do 600 °C CMC 0,045 °C Pt 385 (1000 Ω) od 600 °C do 630 °C CMC 0,047 °C PtNi 385 (120 Ω) od -80 °C do 0 °C CMC 0,21 °C PtNi 385 (120 Ω) od 0 °C do 100 °C CMC 0,21 °C PtNi 385 (120 Ω) od 100 °C do 260 °C CMC 0,21 °C TC K od -200 °C do -100 °C CMC 0,22 °C TC K od -100 °C do -25 °C CMC 0,10 °C TC K od -25 °C do 120 °C CMC 0,09 °C TC K od 120 °C do 1000 °C CMC 0,16 °C TC K od 1000 °C do 1372 °C CMC 0,27 °C TC J od -210 °C do -100 °C CMC 0,19 °C TC J od -100 °C do -30 °C CMC 0,10 °C TC J od -30 °C do 150 °C CMC 0,09 °C TC J od 150 °C do 760 °C CMC 0,11 °C TC J od 760 °C do 1200 °C CMC 0,19 °C Teplota - elektrická simulace / simulátory a zdroje stejnosměrného odporu ekvivalentního teplotě odporové teplotní sondy, simulátory a zdroje stejnosměrného napětí ekvivalentního teplotě termočlánku, procesní kalibrátory Kalibrace – teplota Měření multimetrem přepočtem z výstupního elektrického signálu Pt 385 (100 Ω) -200 °C až -80 °C CMC 0,031 °C Pt 385 (100 Ω) -80 °C až 100 °C CMC 0,020 °C Pt 385 (100 Ω) 100 °C až 300 °C CMC 0,030 °C Pt 385 (100 Ω) 300 °C až 400 °C CMC 0,035 °C Pt 385 (100 Ω) 400 °C až 630 °C CMC 0,047 °C Pt 385 (100 Ω) 630 °C až 800 °C CMC 0,057 °C Pt 3926 (100 Ω) -200 °C až -80 °C CMC 0,031 °C Pt 3926 (100 Ω) -80 °C až 0 °C CMC 0,015 °C Pt 3926 (100 Ω) 0 °C až 100 °C CMC 0,019 °C Pt 3926 (100 Ω) 100 °C až 300 °C CMC 0,029 °C Pt 3926 (100 Ω) 300 °C až 400 °C CMC 0,034 °C Pt 3926 (100 Ω) 400 °C až 630 °C CMC 0,046 °C Pt 3916 (100 Ω) -200 °C až -190 °C CMC 0,028 °C Pt 3916 (100 Ω) -190 °C až -80 °C CMC 0,012 °C Pt 3916 (100 Ω) -80 °C až 0 °C CMC 0,015 °C Pt 3916 (100 Ω) 0 °C až 100 °C CMC 0,019 °C Pt 3916 (100 Ω) 100 °C až 260 °C CMC 0,028 °C Pt 3916 (100 Ω) 260 °C až 300 °C CMC 0,029 °C Pt 3916 (100 Ω) 300 °C až 400 °C CMC 0,034 °C Pt 3916 (100 Ω) 400 °C až 600 °C CMC 0,045 °C Pt 3916 (100 Ω) 600 °C až 630 °C CMC 0,047 °C Pt 385 (200 Ω) -200 °C až -80 °C CMC 0,072 °C Pt 385 (200 Ω) -80 °C až 0 °C CMC 0,076 °C Pt 385 (200 Ω) 0 °C až 100 °C CMC 0,079 °C Pt 385 (200 Ω) 100 °C až 260 °C CMC 0,082 °C Pt 385 (200 Ω) 260 °C až 300 °C CMC 0,090 °C Pt 385 (200 Ω) 300 °C až 400 °C CMC 0,093 °C Pt 385 (200 Ω) 400 °C až 600 °C CMC 0,10 °C Pt 385 (200 Ω) 600 °C až 630 °C CMC 0,10 °C Pt 385 (500 Ω) -200 °C až -80 °C CMC 0,047 °C Pt 385 (500 Ω) -80 °C až 0 °C CMC 0,050 °C Pt 385 (500 Ω) 0 °C až 100 °C CMC 0,045 °C Pt 385 (500 Ω) 100 °C až 260 °C CMC 0,033 °C Pt 385 (500 Ω) 260 °C až 300 °C CMC 0,035 °C Pt 385 (500 Ω) 300 °C až 400 °C CMC 0,041 °C Pt 385 (500 Ω) 400 °C až 600 °C CMC 0,052 °C Pt 385 (500 Ω) 600 °C až 630 °C CMC 0,076 °C Pt 385 (1000 Ω) -200 °C až -80 °C CMC 0,032 °C Pt 385 (1000 Ω) -80 °C až 0 °C CMC 0,035 °C Pt 385 (1000 Ω) 0 °C až 100 °C CMC 0,040 °C Pt 385 (1000 Ω) 100 °C až 260 °C CMC 0,028 °C Pt 385 (1000 Ω) 260 °C až 300 °C CMC 0,030 °C Pt 385 (1000 Ω) 300 °C až 400 °C CMC 0,034 °C Pt 385 (1000 Ω) 400 °C až 600 °C CMC 0,045 °C Pt 385 (1000 Ω) 600 °C až 630 °C CMC 0,047 °C PtNi 385 (120 Ω) -80 °C až 0 °C CMC 0,21 °C PtNi 385 (120 Ω) 0 °C až 100 °C CMC 0,21 °C PtNi 385 (120 Ω) 100 °C až 260 °C CMC 0,21 °C TC K -200 °C až -100 °C CMC 0,22 °C TC K -100 °C až -25 °C CMC 0,10 °C TC K -25 °C až 120 °C CMC 0,09 °C TC K 120 °C až 1000 °C CMC 0,16 °C TC K 1000 °C až 1372 °C CMC 0,27 °C TC J -210 °C až -100 °C CMC 0,19 °C TC J -100 °C až -30 °C CMC 0,10 °C TC J -30 °C až 150 °C CMC 0,09 °C TC J 150 °C až 760 °C CMC 0,11 °C TC J 760 °C až 1200 °C CMC 0,19 °C VKP01/05 Temperatura - symulacja elektryczna / symulatory i zrodla rezystancji odpowiadajacej temperaturze rezystancyjnej sondy temperatury, symulatory i zrodla napiecia stalego odpowiadajacego temperaturze termopary, kalibratory procesowe Wzorcowanie – temperatura Pomiar multimetrem z przeliczeniem z wyjsciowego sygnalu elektrycznego Pt 385 (100 Ω) od -200 °C do -80 °C CMC 0,031 °C Pt 385 (100 Ω) od -80 °C do 100 °C CMC 0,020 °C Pt 385 (100 Ω) od 100 °C do 300 °C CMC 0,030 °C Pt 385 (100 Ω) od 300 °C do 400 °C CMC 0,035 °C Pt 385 (100 Ω) od 400 °C do 630 °C CMC 0,047 °C Pt 385 (100 Ω) od 630 °C do 800 °C CMC 0,057 °C Pt 3926 (100 Ω) od -200 °C do -80 °C CMC 0,031 °C Pt 3926 (100 Ω) od -80 °C do 0 °C CMC 0,015 °C Pt 3926 (100 Ω) od 0 °C do 100 °C CMC 0,019 °C Pt 3926 (100 Ω) od 100 °C do 300 °C CMC 0,029 °C Pt 3926 (100 Ω) od 300 °C do 400 °C CMC 0,034 °C Pt 3926 (100 Ω) od 400 °C do 630 °C CMC 0,046 °C Pt 3916 (100 Ω) od -200 °C do -190 °C CMC 0,028 °C Pt 3916 (100 Ω) od -190 °C do -80 °C CMC 0,012 °C Pt 3916 (100 Ω) od -80 °C do 0 °C CMC 0,015 °C Pt 3916 (100 Ω) od 0 °C do 100 °C CMC 0,019 °C Pt 3916 (100 Ω) od 100 °C do 260 °C CMC 0,028 °C Pt 3916 (100 Ω) od 260 °C do 300 °C CMC 0,029 °C Pt 3916 (100 Ω) od 300 °C do 400 °C CMC 0,034 °C Pt 3916 (100 Ω) od 400 °C do 600 °C CMC 0,045 °C Pt 3916 (100 Ω) od 600 °C do 630 °C CMC 0,047 °C Pt 385 (200 Ω) od -200 °C do -80 °C CMC 0,072 °C Pt 385 (200 Ω) od -80 °C do 0 °C CMC 0,076 °C Pt 385 (200 Ω) od 0 °C do 100 °C CMC 0,079 °C Pt 385 (200 Ω) od 100 °C do 260 °C CMC 0,082 °C Pt 385 (200 Ω) od 260 °C do 300 °C CMC 0,090 °C Pt 385 (200 Ω) od 300 °C do 400 °C CMC 0,093 °C Pt 385 (200 Ω) od 400 °C do 600 °C CMC 0,10 °C Pt 385 (200 Ω) od 600 °C do 630 °C CMC 0,10 °C Pt 385 (500 Ω) od -200 °C do -80 °C CMC 0,047 °C Pt 385 (500 Ω) od -80 °C do 0 °C CMC 0,050 °C Pt 385 (500 Ω) od 0 °C do 100 °C CMC 0,045 °C Pt 385 (500 Ω) od 100 °C do 260 °C CMC 0,033 °C Pt 385 (500 Ω) od 260 °C do 300 °C CMC 0,035 °C Pt 385 (500 Ω) od 300 °C do 400 °C CMC 0,041 °C Pt 385 (500 Ω) od 400 °C do 600 °C CMC 0,052 °C Pt 385 (500 Ω) od 600 °C do 630 °C CMC 0,076 °C Pt 385 (1000 Ω) od -200 °C do -80 °C CMC 0,032 °C Pt 385 (1000 Ω) od -80 °C do 0 °C CMC 0,035 °C Pt 385 (1000 Ω) od 0 °C do 100 °C CMC 0,040 °C Pt 385 (1000 Ω) od 100 °C do 260 °C CMC 0,028 °C Pt 385 (1000 Ω) od 260 °C do 300 °C CMC 0,030 °C Pt 385 (1000 Ω) od 300 °C do 400 °C CMC 0,034 °C Pt 385 (1000 Ω) od 400 °C do 600 °C CMC 0,045 °C Pt 385 (1000 Ω) od 600 °C do 630 °C CMC 0,047 °C PtNi 385 (120 Ω) od -80 °C do 0 °C CMC 0,21 °C PtNi 385 (120 Ω) od 0 °C do 100 °C CMC 0,21 °C PtNi 385 (120 Ω) od 100 °C do 260 °C CMC 0,21 °C TC K od -200 °C do -100 °C CMC 0,22 °C TC K od -100 °C do -25 °C CMC 0,10 °C TC K od -25 °C do 120 °C CMC 0,09 °C TC K od 120 °C do 1000 °C CMC 0,16 °C TC K od 1000 °C do 1372 °C CMC 0,27 °C TC J od -210 °C do -100 °C CMC 0,19 °C TC J od -100 °C do -30 °C CMC 0,10 °C TC J od -30 °C do 150 °C CMC 0,09 °C TC J od 150 °C do 760 °C CMC 0,11 °C TC J od 760 °C do 1200 °C CMC 0,19 °C Teplota - elektricka simulace / simulatory a zdroje stejnosmerneho odporu ekvivalentniho teplote odporove teplotni sondy, simulatory a zdroje stejnosmerneho napeti ekvivalentniho teplote termoclanku, procesni kalibratory Kalibrace – teplota Mereni multimetrem prepoctem z vystupniho elektrickeho signalu Pt 385 (100 Ω) -200 °C az -80 °C CMC 0,031 °C Pt 385 (100 Ω) -80 °C az 100 °C CMC 0,020 °C Pt 385 (100 Ω) 100 °C az 300 °C CMC 0,030 °C Pt 385 (100 Ω) 300 °C az 400 °C CMC 0,035 °C Pt 385 (100 Ω) 400 °C az 630 °C CMC 0,047 °C Pt 385 (100 Ω) 630 °C az 800 °C CMC 0,057 °C Pt 3926 (100 Ω) -200 °C az -80 °C CMC 0,031 °C Pt 3926 (100 Ω) -80 °C az 0 °C CMC 0,015 °C Pt 3926 (100 Ω) 0 °C az 100 °C CMC 0,019 °C Pt 3926 (100 Ω) 100 °C az 300 °C CMC 0,029 °C Pt 3926 (100 Ω) 300 °C az 400 °C CMC 0,034 °C Pt 3926 (100 Ω) 400 °C az 630 °C CMC 0,046 °C Pt 3916 (100 Ω) -200 °C az -190 °C CMC 0,028 °C Pt 3916 (100 Ω) -190 °C az -80 °C CMC 0,012 °C Pt 3916 (100 Ω) -80 °C az 0 °C CMC 0,015 °C Pt 3916 (100 Ω) 0 °C az 100 °C CMC 0,019 °C Pt 3916 (100 Ω) 100 °C az 260 °C CMC 0,028 °C Pt 3916 (100 Ω) 260 °C az 300 °C CMC 0,029 °C Pt 3916 (100 Ω) 300 °C az 400 °C CMC 0,034 °C Pt 3916 (100 Ω) 400 °C az 600 °C CMC 0,045 °C Pt 3916 (100 Ω) 600 °C az 630 °C CMC 0,047 °C Pt 385 (200 Ω) -200 °C az -80 °C CMC 0,072 °C Pt 385 (200 Ω) -80 °C az 0 °C CMC 0,076 °C Pt 385 (200 Ω) 0 °C az 100 °C CMC 0,079 °C Pt 385 (200 Ω) 100 °C az 260 °C CMC 0,082 °C Pt 385 (200 Ω) 260 °C az 300 °C CMC 0,090 °C Pt 385 (200 Ω) 300 °C az 400 °C CMC 0,093 °C Pt 385 (200 Ω) 400 °C az 600 °C CMC 0,10 °C Pt 385 (200 Ω) 600 °C az 630 °C CMC 0,10 °C Pt 385 (500 Ω) -200 °C az -80 °C CMC 0,047 °C Pt 385 (500 Ω) -80 °C az 0 °C CMC 0,050 °C Pt 385 (500 Ω) 0 °C az 100 °C CMC 0,045 °C Pt 385 (500 Ω) 100 °C az 260 °C CMC 0,033 °C Pt 385 (500 Ω) 260 °C az 300 °C CMC 0,035 °C Pt 385 (500 Ω) 300 °C az 400 °C CMC 0,041 °C Pt 385 (500 Ω) 400 °C az 600 °C CMC 0,052 °C Pt 385 (500 Ω) 600 °C az 630 °C CMC 0,076 °C Pt 385 (1000 Ω) -200 °C az -80 °C CMC 0,032 °C Pt 385 (1000 Ω) -80 °C az 0 °C CMC 0,035 °C Pt 385 (1000 Ω) 0 °C az 100 °C CMC 0,040 °C Pt 385 (1000 Ω) 100 °C az 260 °C CMC 0,028 °C Pt 385 (1000 Ω) 260 °C az 300 °C CMC 0,030 °C Pt 385 (1000 Ω) 300 °C az 400 °C CMC 0,034 °C Pt 385 (1000 Ω) 400 °C az 600 °C CMC 0,045 °C Pt 385 (1000 Ω) 600 °C az 630 °C CMC 0,047 °C PtNi 385 (120 Ω) -80 °C az 0 °C CMC 0,21 °C PtNi 385 (120 Ω) 0 °C az 100 °C CMC 0,21 °C PtNi 385 (120 Ω) 100 °C az 260 °C CMC 0,21 °C TC K -200 °C az -100 °C CMC 0,22 °C TC K -100 °C az -25 °C CMC 0,10 °C TC K -25 °C az 120 °C CMC 0,09 °C TC K 120 °C az 1000 °C CMC 0,16 °C TC K 1000 °C az 1372 °C CMC 0,27 °C TC J -210 °C az -100 °C CMC 0,19 °C TC J -100 °C az -30 °C CMC 0,10 °C TC J -30 °C az 150 °C CMC 0,09 °C TC J 150 °C az 760 °C CMC 0,11 °C TC J 760 °C az 1200 °C CMC 0,19 °C VKP01/05","search_en":"Temperature - electrical simulation / simulators and sources of DC resistance equivalent to the temperature of a resistance temperature probe, simulators and sources of DC voltage equivalent to the thermocouple temperature, process calibrators Calibration – temperature Measurement by a multimeter with conversion from the output electrical signal Pt 385 (100 Ω) -200 °C to -80 °C CMC 0,031 °C Pt 385 (100 Ω) -80 °C to 100 °C CMC 0,020 °C Pt 385 (100 Ω) 100 °C to 300 °C CMC 0,030 °C Pt 385 (100 Ω) 300 °C to 400 °C CMC 0,035 °C Pt 385 (100 Ω) 400 °C to 630 °C CMC 0,047 °C Pt 385 (100 Ω) 630 °C to 800 °C CMC 0,057 °C Pt 3926 (100 Ω) -200 °C to -80 °C CMC 0,031 °C Pt 3926 (100 Ω) -80 °C to 0 °C CMC 0,015 °C Pt 3926 (100 Ω) 0 °C to 100 °C CMC 0,019 °C Pt 3926 (100 Ω) 100 °C to 300 °C CMC 0,029 °C Pt 3926 (100 Ω) 300 °C to 400 °C CMC 0,034 °C Pt 3926 (100 Ω) 400 °C to 630 °C CMC 0,046 °C Pt 3916 (100 Ω) -200 °C to -190 °C CMC 0,028 °C Pt 3916 (100 Ω) -190 °C to -80 °C CMC 0,012 °C Pt 3916 (100 Ω) -80 °C to 0 °C CMC 0,015 °C Pt 3916 (100 Ω) 0 °C to 100 °C CMC 0,019 °C Pt 3916 (100 Ω) 100 °C to 260 °C CMC 0,028 °C Pt 3916 (100 Ω) 260 °C to 300 °C CMC 0,029 °C Pt 3916 (100 Ω) 300 °C to 400 °C CMC 0,034 °C Pt 3916 (100 Ω) 400 °C to 600 °C CMC 0,045 °C Pt 3916 (100 Ω) 600 °C to 630 °C CMC 0,047 °C Pt 385 (200 Ω) -200 °C to -80 °C CMC 0,072 °C Pt 385 (200 Ω) -80 °C to 0 °C CMC 0,076 °C Pt 385 (200 Ω) 0 °C to 100 °C CMC 0,079 °C Pt 385 (200 Ω) 100 °C to 260 °C CMC 0,082 °C Pt 385 (200 Ω) 260 °C to 300 °C CMC 0,090 °C Pt 385 (200 Ω) 300 °C to 400 °C CMC 0,093 °C Pt 385 (200 Ω) 400 °C to 600 °C CMC 0,10 °C Pt 385 (200 Ω) 600 °C to 630 °C CMC 0,10 °C Pt 385 (500 Ω) -200 °C to -80 °C CMC 0,047 °C Pt 385 (500 Ω) -80 °C to 0 °C CMC 0,050 °C Pt 385 (500 Ω) 0 °C to 100 °C CMC 0,045 °C Pt 385 (500 Ω) 100 °C to 260 °C CMC 0,033 °C Pt 385 (500 Ω) 260 °C to 300 °C CMC 0,035 °C Pt 385 (500 Ω) 300 °C to 400 °C CMC 0,041 °C Pt 385 (500 Ω) 400 °C to 600 °C CMC 0,052 °C Pt 385 (500 Ω) 600 °C to 630 °C CMC 0,076 °C Pt 385 (1000 Ω) -200 °C to -80 °C CMC 0,032 °C Pt 385 (1000 Ω) -80 °C to 0 °C CMC 0,035 °C Pt 385 (1000 Ω) 0 °C to 100 °C CMC 0,040 °C Pt 385 (1000 Ω) 100 °C to 260 °C CMC 0,028 °C Pt 385 (1000 Ω) 260 °C to 300 °C CMC 0,030 °C Pt 385 (1000 Ω) 300 °C to 400 °C CMC 0,034 °C Pt 385 (1000 Ω) 400 °C to 600 °C CMC 0,045 °C Pt 385 (1000 Ω) 600 °C to 630 °C CMC 0,047 °C PtNi 385 (120 Ω) -80 °C to 0 °C CMC 0,21 °C PtNi 385 (120 Ω) 0 °C to 100 °C CMC 0,21 °C PtNi 385 (120 Ω) 100 °C to 260 °C CMC 0,21 °C TC K -200 °C to -100 °C CMC 0,22 °C TC K -100 °C to -25 °C CMC 0,10 °C TC K -25 °C to 120 °C CMC 0,09 °C TC K 120 °C to 1000 °C CMC 0,16 °C TC K 1000 °C to 1372 °C CMC 0,27 °C TC J -210 °C to -100 °C CMC 0,19 °C TC J -100 °C to -30 °C CMC 0,10 °C TC J -30 °C to 150 °C CMC 0,09 °C TC J 150 °C to 760 °C CMC 0,11 °C TC J 760 °C to 1200 °C CMC 0,19 °C VKP01/05","search_zh":"温度 - 电模拟 / 等效于电阻温度探头温度的直流电阻模拟器和源、等效于热电偶温度的直流电压模拟器和源、过程校准器 校准 – 温度 用万用表测量并由输出电信号换算 Pt 385 (100 Ω) -200 °C 至 -80 °C CMC 0,031 °C Pt 385 (100 Ω) -80 °C 至 100 °C CMC 0,020 °C Pt 385 (100 Ω) 100 °C 至 300 °C CMC 0,030 °C Pt 385 (100 Ω) 300 °C 至 400 °C CMC 0,035 °C Pt 385 (100 Ω) 400 °C 至 630 °C CMC 0,047 °C Pt 385 (100 Ω) 630 °C 至 800 °C CMC 0,057 °C Pt 3926 (100 Ω) -200 °C 至 -80 °C CMC 0,031 °C Pt 3926 (100 Ω) -80 °C 至 0 °C CMC 0,015 °C Pt 3926 (100 Ω) 0 °C 至 100 °C CMC 0,019 °C Pt 3926 (100 Ω) 100 °C 至 300 °C CMC 0,029 °C Pt 3926 (100 Ω) 300 °C 至 400 °C CMC 0,034 °C Pt 3926 (100 Ω) 400 °C 至 630 °C CMC 0,046 °C Pt 3916 (100 Ω) -200 °C 至 -190 °C CMC 0,028 °C Pt 3916 (100 Ω) -190 °C 至 -80 °C CMC 0,012 °C Pt 3916 (100 Ω) -80 °C 至 0 °C CMC 0,015 °C Pt 3916 (100 Ω) 0 °C 至 100 °C CMC 0,019 °C Pt 3916 (100 Ω) 100 °C 至 260 °C CMC 0,028 °C Pt 3916 (100 Ω) 260 °C 至 300 °C CMC 0,029 °C Pt 3916 (100 Ω) 300 °C 至 400 °C CMC 0,034 °C Pt 3916 (100 Ω) 400 °C 至 600 °C CMC 0,045 °C Pt 3916 (100 Ω) 600 °C 至 630 °C CMC 0,047 °C Pt 385 (200 Ω) -200 °C 至 -80 °C CMC 0,072 °C Pt 385 (200 Ω) -80 °C 至 0 °C CMC 0,076 °C Pt 385 (200 Ω) 0 °C 至 100 °C CMC 0,079 °C Pt 385 (200 Ω) 100 °C 至 260 °C CMC 0,082 °C Pt 385 (200 Ω) 260 °C 至 300 °C CMC 0,090 °C Pt 385 (200 Ω) 300 °C 至 400 °C CMC 0,093 °C Pt 385 (200 Ω) 400 °C 至 600 °C CMC 0,10 °C Pt 385 (200 Ω) 600 °C 至 630 °C CMC 0,10 °C Pt 385 (500 Ω) -200 °C 至 -80 °C CMC 0,047 °C Pt 385 (500 Ω) -80 °C 至 0 °C CMC 0,050 °C Pt 385 (500 Ω) 0 °C 至 100 °C CMC 0,045 °C Pt 385 (500 Ω) 100 °C 至 260 °C CMC 0,033 °C Pt 385 (500 Ω) 260 °C 至 300 °C CMC 0,035 °C Pt 385 (500 Ω) 300 °C 至 400 °C CMC 0,041 °C Pt 385 (500 Ω) 400 °C 至 600 °C CMC 0,052 °C Pt 385 (500 Ω) 600 °C 至 630 °C CMC 0,076 °C Pt 385 (1000 Ω) -200 °C 至 -80 °C CMC 0,032 °C Pt 385 (1000 Ω) -80 °C 至 0 °C CMC 0,035 °C Pt 385 (1000 Ω) 0 °C 至 100 °C CMC 0,040 °C Pt 385 (1000 Ω) 100 °C 至 260 °C CMC 0,028 °C Pt 385 (1000 Ω) 260 °C 至 300 °C CMC 0,030 °C Pt 385 (1000 Ω) 300 °C 至 400 °C CMC 0,034 °C Pt 385 (1000 Ω) 400 °C 至 600 °C CMC 0,045 °C Pt 385 (1000 Ω) 600 °C 至 630 °C CMC 0,047 °C PtNi 385 (120 Ω) -80 °C 至 0 °C CMC 0,21 °C PtNi 385 (120 Ω) 0 °C 至 100 °C CMC 0,21 °C PtNi 385 (120 Ω) 100 °C 至 260 °C CMC 0,21 °C K 型热电偶 -200 °C 至 -100 °C CMC 0,22 °C K 型热电偶 -100 °C 至 -25 °C CMC 0,10 °C K 型热电偶 -25 °C 至 120 °C CMC 0,09 °C K 型热电偶 120 °C 至 1000 °C CMC 0,16 °C K 型热电偶 1000 °C 至 1372 °C CMC 0,27 °C J 型热电偶 -210 °C 至 -100 °C CMC 0,19 °C J 型热电偶 -100 °C 至 -30 °C CMC 0,10 °C J 型热电偶 -30 °C 至 150 °C CMC 0,09 °C J 型热电偶 150 °C 至 760 °C CMC 0,11 °C J 型热电偶 760 °C 至 1200 °C CMC 0,19 °C VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"900481338daa639ec48cb0a9","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / mierniki napięcia stałego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi","test_object_en":"DC voltage / DC voltage meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers","test_object_zh":"直流电压 / 直流电压表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪","test_object_cs":"Stejnosměrné napětí / měřidla stejnosměrného napětí, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 120 mV","cmc":"9,3 µV/V +0,8 µV"},{"name":"","range":"od 120 mV do 1,2 V","cmc":"6,4 µV/V +1 µV"},{"name":"","range":"od 1,2 V do 12 V","cmc":"6,2 µV/V +10 µV"},{"name":"","range":"od 12 V do 120 V","cmc":"8,5 µV/V +0,1 mV"},{"name":"","range":"od 120 V do 1020 V","cmc":"8,5 µV/V +1 mV"}],"parameters_en":[{"name":"","range":"0 mV to 120 mV","cmc":"9,3 µV/V +0,8 µV"},{"name":"","range":"120 mV to 1,2 V","cmc":"6,4 µV/V +1 µV"},{"name":"","range":"1,2 V to 12 V","cmc":"6,2 µV/V +10 µV"},{"name":"","range":"12 V to 120 V","cmc":"8,5 µV/V +0,1 mV"},{"name":"","range":"120 V to 1020 V","cmc":"8,5 µV/V +1 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 120 mV","cmc":"9,3 µV/V +0,8 µV"},{"name":"","range":"120 mV 至 1,2 V","cmc":"6,4 µV/V +1 µV"},{"name":"","range":"1,2 V 至 12 V","cmc":"6,2 µV/V +10 µV"},{"name":"","range":"12 V 至 120 V","cmc":"8,5 µV/V +0,1 mV"},{"name":"","range":"120 V 至 1020 V","cmc":"8,5 µV/V +1 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 120 mV","cmc":"9,3 µV/V +0,8 µV"},{"name":"","range":"120 mV až 1,2 V","cmc":"6,4 µV/V +1 µV"},{"name":"","range":"1,2 V až 12 V","cmc":"6,2 µV/V +10 µV"},{"name":"","range":"12 V až 120 V","cmc":"8,5 µV/V +0,1 mV"},{"name":"","range":"120 V až 1020 V","cmc":"8,5 µV/V +1 mV"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation by a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation by a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 120 mV CMC 9,3 µV/V +0,8 µV\nod 120 mV do 1,2 V CMC 6,4 µV/V +1 µV\nod 1,2 V do 12 V CMC 6,2 µV/V +10 µV\nod 12 V do 120 V CMC 8,5 µV/V +0,1 mV\nod 120 V do 1020 V CMC 8,5 µV/V +1 mV\nBezpośrednie generowanie kalibratorem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / mierniki napięcia stałego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0 mV do 120 mV CMC 9,3 µV/V +0,8 µV od 120 mV do 1,2 V CMC 6,4 µV/V +1 µV od 1,2 V do 12 V CMC 6,2 µV/V +10 µV od 12 V do 120 V CMC 8,5 µV/V +0,1 mV od 120 V do 1020 V CMC 8,5 µV/V +1 mV Stejnosměrné napětí / měřidla stejnosměrného napětí, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0 mV až 120 mV CMC 9,3 µV/V +0,8 µV 120 mV až 1,2 V CMC 6,4 µV/V +1 µV 1,2 V až 12 V CMC 6,2 µV/V +10 µV 12 V až 120 V CMC 8,5 µV/V +0,1 mV 120 V až 1020 V CMC 8,5 µV/V +1 mV VKP01/05 VKP02/05 Napiecie stale / mierniki napiecia stalego, kalibratory, multimetry, mierniki cegowe, mierniki do badan instalacji, testery wielofunkcyjne, mierniki rezystancji uziemien, mierniki uziemien, testery elektronarzedzi Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0 mV do 120 mV CMC 9,3 µV/V +0,8 µV od 120 mV do 1,2 V CMC 6,4 µV/V +1 µV od 1,2 V do 12 V CMC 6,2 µV/V +10 µV od 12 V do 120 V CMC 8,5 µV/V +0,1 mV od 120 V do 1020 V CMC 8,5 µV/V +1 mV Stejnosmerne napeti / meridla stejnosmerneho napeti, kalibratory, multimetry, klestova meridla, revizni meridla, multifunkcni testery, merice zemniho odporu, meridla uzemneni, testery rucniho naradi Kalibrace – elektricke veliciny Prime generovani kalibratorem 0 mV az 120 mV CMC 9,3 µV/V +0,8 µV 120 mV az 1,2 V CMC 6,4 µV/V +1 µV 1,2 V az 12 V CMC 6,2 µV/V +10 µV 12 V az 120 V CMC 8,5 µV/V +0,1 mV 120 V az 1020 V CMC 8,5 µV/V +1 mV VKP01/05 VKP02/05","search_en":"DC voltage / DC voltage meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers Calibration – electrical quantities Direct generation by a calibrator 0 mV to 120 mV CMC 9,3 µV/V +0,8 µV 120 mV to 1,2 V CMC 6,4 µV/V +1 µV 1,2 V to 12 V CMC 6,2 µV/V +10 µV 12 V to 120 V CMC 8,5 µV/V +0,1 mV 120 V to 1020 V CMC 8,5 µV/V +1 mV VKP01/05 VKP02/05","search_zh":"直流电压 / 直流电压表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪 校准 – 电学量 用校准器直接产生 0 mV 至 120 mV CMC 9,3 µV/V +0,8 µV 120 mV 至 1,2 V CMC 6,4 µV/V +1 µV 1,2 V 至 12 V CMC 6,2 µV/V +10 µV 12 V 至 120 V CMC 8,5 µV/V +0,1 mV 120 V 至 1020 V CMC 8,5 µV/V +1 mV VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9523b76f46120672237f4c98","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / źródła napięcia stałego","test_object_en":"DC voltage / DC voltage sources","test_object_zh":"直流电压 / 直流电压源","test_object_cs":"Stejnosměrné napětí / zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,025 % +3,5 µV"},{"name":"","range":"od 100 mV do 1 V","cmc":"0,0018 % +7 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,0018 % +50 µV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,0027 % +0,6 mV"},{"name":"","range":"od 100 V do 1 kV","cmc":"0,0031 % +10 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,025 % +3,5 µV"},{"name":"","range":"100 mV to 1 V","cmc":"0,0018 % +7 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0018 % +50 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,0027 % +0,6 mV"},{"name":"","range":"100 V to 1 kV","cmc":"0,0031 % +10 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,025 % +3,5 µV"},{"name":"","range":"100 mV 至 1 V","cmc":"0,0018 % +7 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,0018 % +50 µV"},{"name":"","range":"10 V 至 100 V","cmc":"0,0027 % +0,6 mV"},{"name":"","range":"100 V 至 1 kV","cmc":"0,0031 % +10 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,025 % +3,5 µV"},{"name":"","range":"100 mV až 1 V","cmc":"0,0018 % +7 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,0018 % +50 µV"},{"name":"","range":"10 V až 100 V","cmc":"0,0027 % +0,6 mV"},{"name":"","range":"100 V až 1 kV","cmc":"0,0031 % +10 mV"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement by a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement by a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,025 % +3,5 µV\nod 100 mV do 1 V CMC 0,0018 % +7 µV\nod 1 V do 10 V CMC 0,0018 % +50 µV\nod 10 V do 100 V CMC 0,0027 % +0,6 mV\nod 100 V do 1 kV CMC 0,0031 % +10 mV\nPomiar bezpośredni multimetrem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / źródła napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 mV do 100 mV CMC 0,025 % +3,5 µV od 100 mV do 1 V CMC 0,0018 % +7 µV od 1 V do 10 V CMC 0,0018 % +50 µV od 10 V do 100 V CMC 0,0027 % +0,6 mV od 100 V do 1 kV CMC 0,0031 % +10 mV Stejnosměrné napětí / zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Přímé měření multimetrem 0 mV až 100 mV CMC 0,025 % +3,5 µV 100 mV až 1 V CMC 0,0018 % +7 µV 1 V až 10 V CMC 0,0018 % +50 µV 10 V až 100 V CMC 0,0027 % +0,6 mV 100 V až 1 kV CMC 0,0031 % +10 mV VKP01/05 VKP02/05 Napiecie stale / zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 mV do 100 mV CMC 0,025 % +3,5 µV od 100 mV do 1 V CMC 0,0018 % +7 µV od 1 V do 10 V CMC 0,0018 % +50 µV od 10 V do 100 V CMC 0,0027 % +0,6 mV od 100 V do 1 kV CMC 0,0031 % +10 mV Stejnosmerne napeti / zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Prime mereni multimetrem 0 mV az 100 mV CMC 0,025 % +3,5 µV 100 mV az 1 V CMC 0,0018 % +7 µV 1 V az 10 V CMC 0,0018 % +50 µV 10 V az 100 V CMC 0,0027 % +0,6 mV 100 V az 1 kV CMC 0,0031 % +10 mV VKP01/05 VKP02/05","search_en":"DC voltage / DC voltage sources Calibration – electrical quantities Direct measurement by a multimeter 0 mV to 100 mV CMC 0,025 % +3,5 µV 100 mV to 1 V CMC 0,0018 % +7 µV 1 V to 10 V CMC 0,0018 % +50 µV 10 V to 100 V CMC 0,0027 % +0,6 mV 100 V to 1 kV CMC 0,0031 % +10 mV VKP01/05 VKP02/05","search_zh":"直流电压 / 直流电压源 校准 – 电学量 用万用表直接测量 0 mV 至 100 mV CMC 0,025 % +3,5 µV 100 mV 至 1 V CMC 0,0018 % +7 µV 1 V 至 10 V CMC 0,0018 % +50 µV 10 V 至 100 V CMC 0,0027 % +0,6 mV 100 V 至 1 kV CMC 0,0031 % +10 mV VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75dacce50c17fead6368ec48","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / źródła napięcia stałego","test_object_en":"DC voltage / DC voltage sources","test_object_zh":"直流电压 / 直流电压源","test_object_cs":"Stejnosměrné napětí / zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 kV do 10 kV","cmc":"0,3 % +5 V"}],"parameters_en":[{"name":"","range":"1 kV to 10 kV","cmc":"0,3 % +5 V"}],"parameters_zh":[{"name":"","range":"1 kV 至 10 kV","cmc":"0,3 % +5 V"}],"parameters_cs":[{"name":"","range":"1 kV až 10 kV","cmc":"0,3 % +5 V"}],"technique":"Pomiar pośredni kalibratorem mierników do badań instalacji z dzielnikiem wysokonapięciowym","technique_en":"Indirect measurement by an installation tester calibrator with a high-voltage divider","technique_zh":"用带高压分压器的电气安装测试仪校准器间接测量","technique_cs":"Nepřímé měření kalibrátorem revizních přístrojů s vysokonapěťovým děličem","techniques":["Pomiar pośredni kalibratorem mierników do badań instalacji z dzielnikiem wysokonapięciowym"],"techniques_en":["Indirect measurement by an installation tester calibrator with a high-voltage divider"],"techniques_zh":["用带高压分压器的电气安装测试仪校准器间接测量"],"techniques_cs":["Nepřímé měření kalibrátorem revizních přístrojů s vysokonapěťovým děličem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 kV do 10 kV CMC 0,3 % +5 V\nPomiar pośredni kalibratorem mierników do badań instalacji z dzielnikiem wysokonapięciowym","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / źródła napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar pośredni kalibratorem mierników do badań instalacji z dzielnikiem wysokonapięciowym od 1 kV do 10 kV CMC 0,3 % +5 V Stejnosměrné napětí / zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Nepřímé měření kalibrátorem revizních přístrojů s vysokonapěťovým děličem 1 kV až 10 kV CMC 0,3 % +5 V VKP01/05 VKP02/05 Napiecie stale / zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar posredni kalibratorem miernikow do badan instalacji z dzielnikiem wysokonapieciowym od 1 kV do 10 kV CMC 0,3 % +5 V Stejnosmerne napeti / zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Neprime mereni kalibratorem reviznich pristroju s vysokonapetovym delicem 1 kV az 10 kV CMC 0,3 % +5 V VKP01/05 VKP02/05","search_en":"DC voltage / DC voltage sources Calibration – electrical quantities Indirect measurement by an installation tester calibrator with a high-voltage divider 1 kV to 10 kV CMC 0,3 % +5 V VKP01/05 VKP02/05","search_zh":"直流电压 / 直流电压源 校准 – 电学量 用带高压分压器的电气安装测试仪校准器间接测量 1 kV 至 10 kV CMC 0,3 % +5 V VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d1eb28c6c4844aaf4d0ccf8b","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / mierniki napięcia przemiennego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi","test_object_en":"AC voltage / AC voltage meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers","test_object_zh":"交流电压 / 交流电压表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪","test_object_cs":"Střídavé napětí / měřidla střídavého napětí, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"3 Hz do 5 Hz","range":"od 1 mV do 12 mV","cmc":"1 900 µV/V +7 µV"},{"name":"5 Hz do 10 Hz","range":"od 1 mV do 12 mV","cmc":"680 µV/V +7 µV"},{"name":"10 Hz do 20 kHz","range":"od 1 mV do 12 mV","cmc":"120 µV/V +6 µV"},{"name":"20 kHz do 50 kHz","range":"od 1 mV do 12 mV","cmc":"290 µV/V +6 µV"},{"name":"50 kHz do 100 kHz","range":"od 1 mV do 12 mV","cmc":"1200 µV/V +15 µV"},{"name":"100 kHz do 500 kHz","range":"od 1 mV do 12 mV","cmc":"6 200 µV/V +30 µV"},{"name":"3 Hz do 5 Hz","range":"od 12 mV do 120 mV","cmc":"1 900 µV/V +7 µV"},{"name":"5 Hz do 10 Hz","range":"od 12 mV do 120 mV","cmc":"680 µV/V +7 µV"},{"name":"10 Hz do 20 kHz","range":"od 12 mV do 120 mV","cmc":"110 µV/V +6 µV"},{"name":"20 kHz do 50 kHz","range":"od 12 mV do 120 mV","cmc":"270 µV/V +8 µV"},{"name":"50 kHz do 100 kHz","range":"od 12 mV do 120 mV","cmc":"620 µV/V +20 µV"},{"name":"100 kHz do 500 kHz","range":"od 12 mV do 120 mV","cmc":"1 600 µV/V +30 µV"},{"name":"3 Hz do 5 Hz","range":"od 120 mV do 1,2 V","cmc":"1 900 µV/V +75 µV"},{"name":"5 Hz do 10 Hz","range":"od 120 mV do 1,2 V","cmc":"680 µV/V +70 µV"},{"name":"10 Hz do 40 Hz","range":"od 120 mV do 1,2 V","cmc":"110 µV/V +60 µV"},{"name":"40,01 Hz do 20 kHz","range":"od 120 mV do 1,2 V","cmc":"110 µV/V +8 µV"},{"name":"20 kHz do 50 kHz","range":"od 120 mV do 1,2 V","cmc":"230 µV/V +14 µV"},{"name":"50 kHz do 100 kHz","range":"od 120 mV do 1,2 V","cmc":"540 µV/V +40 µV"},{"name":"100 kHz do 500 kHz","range":"od 120 mV do 1,2 V","cmc":"1 500 µV/V +80 µV"},{"name":"3 Hz do 5 Hz","range":"od 1,2 V do 12 V","cmc":"1 900 µV/V +750 µV"},{"name":"5 Hz do 10 Hz","range":"od 1,2 V do 12 V","cmc":"680 µV/V +750 µV"},{"name":"10 Hz do 40 Hz","range":"od 1,2 V do 12 V","cmc":"110 µV/V +350 µV"},{"name":"40,01 Hz do 20 kHz","range":"od 1,2 V do 12 V","cmc":"110 µV/V +50 µV"},{"name":"20 kHz do 50 kHz","range":"od 1,2 V do 12 V","cmc":"230 µV/V +50 µV"},{"name":"50 kHz do 100 kHz","range":"od 1,2 V do 12 V","cmc":"540 µV/V +125 µV"},{"name":"100 kHz do 500 kHz","range":"od 1,2 V do 12 V","cmc":"1 600 µV/V +600 µV"},{"name":"3 Hz do 5 Hz","range":"od 12 V do 120 V","cmc":"1 900 µV/V +7 500 µV"},{"name":"5 Hz do 10 Hz","range":"od 12 V do 120 V","cmc":"680 µV/V +7 500 µV"},{"name":"10 Hz do 40 Hz","range":"od 12 V do 120 V","cmc":"110 µV/V +3 500 µV"},{"name":"40,01 Hz do 20 kHz","range":"od 12 V do 120 V","cmc":"110 µV/V +500 µV"},{"name":"20 kHz do 50 kHz","range":"od 12 V do 120 V","cmc":"230 µV/V +500 µV"},{"name":"50 kHz do 100 kHz","range":"od 12 V do 120 V","cmc":"540 µV/V +1 250 µV"},{"name":"100 kHz do 300 kHz (maks. 70 V)","range":"od 12 V do 120 V","cmc":"1 600 µV/V +20 mV"},{"name":"3 Hz do 5 Hz","range":"od 120 V do 330 V","cmc":"1 900 µV/V +75 mV"},{"name":"5 Hz do 10 Hz","range":"od 120 V do 330 V","cmc":"680 µV/V +75 mV"},{"name":"10 Hz do 20 kHz","range":"od 120 V do 330 V","cmc":"110 µV/V +8 mV"},{"name":"20 kHz do 50 kHz","range":"od 120 V do 330 V","cmc":"230 µV/V +8 mV"},{"name":"50 kHz do 100 kHz","range":"od 120 V do 330 V","cmc":"1 200 µV/V +12,5 mV"},{"name":"3 Hz do 5 Hz","range":"od 330 V do 1020 V","cmc":"1 900 µV/V +75 mV"},{"name":"5 Hz do 10 Hz","range":"od 330 V do 1020 V","cmc":"680 µV/V +75 mV"},{"name":"10 Hz do 10 kHz","range":"od 330 V do 1020 V","cmc":"110 µV/V +80 mV"}],"parameters_en":[{"name":"3 Hz to 5 Hz","range":"1 mV to 12 mV","cmc":"1 900 µV/V +7 µV"},{"name":"5 Hz to 10 Hz","range":"1 mV to 12 mV","cmc":"680 µV/V +7 µV"},{"name":"10 Hz to 20 kHz","range":"1 mV to 12 mV","cmc":"120 µV/V +6 µV"},{"name":"20 kHz to 50 kHz","range":"1 mV to 12 mV","cmc":"290 µV/V +6 µV"},{"name":"50 kHz to 100 kHz","range":"1 mV to 12 mV","cmc":"1200 µV/V +15 µV"},{"name":"100 kHz to 500 kHz","range":"1 mV to 12 mV","cmc":"6 200 µV/V +30 µV"},{"name":"3 Hz to 5 Hz","range":"12 mV to 120 mV","cmc":"1 900 µV/V +7 µV"},{"name":"5 Hz to 10 Hz","range":"12 mV to 120 mV","cmc":"680 µV/V +7 µV"},{"name":"10 Hz to 20 kHz","range":"12 mV to 120 mV","cmc":"110 µV/V +6 µV"},{"name":"20 kHz to 50 kHz","range":"12 mV to 120 mV","cmc":"270 µV/V +8 µV"},{"name":"50 kHz to 100 kHz","range":"12 mV to 120 mV","cmc":"620 µV/V +20 µV"},{"name":"100 kHz to 500 kHz","range":"12 mV to 120 mV","cmc":"1 600 µV/V +30 µV"},{"name":"3 Hz to 5 Hz","range":"120 mV to 1,2 V","cmc":"1 900 µV/V +75 µV"},{"name":"5 Hz to 10 Hz","range":"120 mV to 1,2 V","cmc":"680 µV/V +70 µV"},{"name":"10 Hz to 40 Hz","range":"120 mV to 1,2 V","cmc":"110 µV/V +60 µV"},{"name":"40,01 Hz to 20 kHz","range":"120 mV to 1,2 V","cmc":"110 µV/V +8 µV"},{"name":"20 kHz to 50 kHz","range":"120 mV to 1,2 V","cmc":"230 µV/V +14 µV"},{"name":"50 kHz to 100 kHz","range":"120 mV to 1,2 V","cmc":"540 µV/V +40 µV"},{"name":"100 kHz to 500 kHz","range":"120 mV to 1,2 V","cmc":"1 500 µV/V +80 µV"},{"name":"3 Hz to 5 Hz","range":"1,2 V to 12 V","cmc":"1 900 µV/V +750 µV"},{"name":"5 Hz to 10 Hz","range":"1,2 V to 12 V","cmc":"680 µV/V +750 µV"},{"name":"10 Hz to 40 Hz","range":"1,2 V to 12 V","cmc":"110 µV/V +350 µV"},{"name":"40,01 Hz to 20 kHz","range":"1,2 V to 12 V","cmc":"110 µV/V +50 µV"},{"name":"20 kHz to 50 kHz","range":"1,2 V to 12 V","cmc":"230 µV/V +50 µV"},{"name":"50 kHz to 100 kHz","range":"1,2 V to 12 V","cmc":"540 µV/V +125 µV"},{"name":"100 kHz to 500 kHz","range":"1,2 V to 12 V","cmc":"1 600 µV/V +600 µV"},{"name":"3 Hz to 5 Hz","range":"12 V to 120 V","cmc":"1 900 µV/V +7 500 µV"},{"name":"5 Hz to 10 Hz","range":"12 V to 120 V","cmc":"680 µV/V +7 500 µV"},{"name":"10 Hz to 40 Hz","range":"12 V to 120 V","cmc":"110 µV/V +3 500 µV"},{"name":"40,01 Hz to 20 kHz","range":"12 V to 120 V","cmc":"110 µV/V +500 µV"},{"name":"20 kHz to 50 kHz","range":"12 V to 120 V","cmc":"230 µV/V +500 µV"},{"name":"50 kHz to 100 kHz","range":"12 V to 120 V","cmc":"540 µV/V +1 250 µV"},{"name":"100 kHz to 300 kHz (max. 70 V)","range":"12 V to 120 V","cmc":"1 600 µV/V +20 mV"},{"name":"3 Hz to 5 Hz","range":"120 V to 330 V","cmc":"1 900 µV/V +75 mV"},{"name":"5 Hz to 10 Hz","range":"120 V to 330 V","cmc":"680 µV/V +75 mV"},{"name":"10 Hz to 20 kHz","range":"120 V to 330 V","cmc":"110 µV/V +8 mV"},{"name":"20 kHz to 50 kHz","range":"120 V to 330 V","cmc":"230 µV/V +8 mV"},{"name":"50 kHz to 100 kHz","range":"120 V to 330 V","cmc":"1 200 µV/V +12,5 mV"},{"name":"3 Hz to 5 Hz","range":"330 V to 1020 V","cmc":"1 900 µV/V +75 mV"},{"name":"5 Hz to 10 Hz","range":"330 V to 1020 V","cmc":"680 µV/V +75 mV"},{"name":"10 Hz to 10 kHz","range":"330 V to 1020 V","cmc":"110 µV/V +80 mV"}],"parameters_zh":[{"name":"3 Hz 至 5 Hz","range":"1 mV 至 12 mV","cmc":"1 900 µV/V +7 µV"},{"name":"5 Hz 至 10 Hz","range":"1 mV 至 12 mV","cmc":"680 µV/V +7 µV"},{"name":"10 Hz 至 20 kHz","range":"1 mV 至 12 mV","cmc":"120 µV/V +6 µV"},{"name":"20 kHz 至 50 kHz","range":"1 mV 至 12 mV","cmc":"290 µV/V +6 µV"},{"name":"50 kHz 至 100 kHz","range":"1 mV 至 12 mV","cmc":"1200 µV/V +15 µV"},{"name":"100 kHz 至 500 kHz","range":"1 mV 至 12 mV","cmc":"6 200 µV/V +30 µV"},{"name":"3 Hz 至 5 Hz","range":"12 mV 至 120 mV","cmc":"1 900 µV/V +7 µV"},{"name":"5 Hz 至 10 Hz","range":"12 mV 至 120 mV","cmc":"680 µV/V +7 µV"},{"name":"10 Hz 至 20 kHz","range":"12 mV 至 120 mV","cmc":"110 µV/V +6 µV"},{"name":"20 kHz 至 50 kHz","range":"12 mV 至 120 mV","cmc":"270 µV/V +8 µV"},{"name":"50 kHz 至 100 kHz","range":"12 mV 至 120 mV","cmc":"620 µV/V +20 µV"},{"name":"100 kHz 至 500 kHz","range":"12 mV 至 120 mV","cmc":"1 600 µV/V +30 µV"},{"name":"3 Hz 至 5 Hz","range":"120 mV 至 1,2 V","cmc":"1 900 µV/V +75 µV"},{"name":"5 Hz 至 10 Hz","range":"120 mV 至 1,2 V","cmc":"680 µV/V +70 µV"},{"name":"10 Hz 至 40 Hz","range":"120 mV 至 1,2 V","cmc":"110 µV/V +60 µV"},{"name":"40,01 Hz 至 20 kHz","range":"120 mV 至 1,2 V","cmc":"110 µV/V +8 µV"},{"name":"20 kHz 至 50 kHz","range":"120 mV 至 1,2 V","cmc":"230 µV/V +14 µV"},{"name":"50 kHz 至 100 kHz","range":"120 mV 至 1,2 V","cmc":"540 µV/V +40 µV"},{"name":"100 kHz 至 500 kHz","range":"120 mV 至 1,2 V","cmc":"1 500 µV/V +80 µV"},{"name":"3 Hz 至 5 Hz","range":"1,2 V 至 12 V","cmc":"1 900 µV/V +750 µV"},{"name":"5 Hz 至 10 Hz","range":"1,2 V 至 12 V","cmc":"680 µV/V +750 µV"},{"name":"10 Hz 至 40 Hz","range":"1,2 V 至 12 V","cmc":"110 µV/V +350 µV"},{"name":"40,01 Hz 至 20 kHz","range":"1,2 V 至 12 V","cmc":"110 µV/V +50 µV"},{"name":"20 kHz 至 50 kHz","range":"1,2 V 至 12 V","cmc":"230 µV/V +50 µV"},{"name":"50 kHz 至 100 kHz","range":"1,2 V 至 12 V","cmc":"540 µV/V +125 µV"},{"name":"100 kHz 至 500 kHz","range":"1,2 V 至 12 V","cmc":"1 600 µV/V +600 µV"},{"name":"3 Hz 至 5 Hz","range":"12 V 至 120 V","cmc":"1 900 µV/V +7 500 µV"},{"name":"5 Hz 至 10 Hz","range":"12 V 至 120 V","cmc":"680 µV/V +7 500 µV"},{"name":"10 Hz 至 40 Hz","range":"12 V 至 120 V","cmc":"110 µV/V +3 500 µV"},{"name":"40,01 Hz 至 20 kHz","range":"12 V 至 120 V","cmc":"110 µV/V +500 µV"},{"name":"20 kHz 至 50 kHz","range":"12 V 至 120 V","cmc":"230 µV/V +500 µV"},{"name":"50 kHz 至 100 kHz","range":"12 V 至 120 V","cmc":"540 µV/V +1 250 µV"},{"name":"100 kHz 至 300 kHz（最大 70 V）","range":"12 V 至 120 V","cmc":"1 600 µV/V +20 mV"},{"name":"3 Hz 至 5 Hz","range":"120 V 至 330 V","cmc":"1 900 µV/V +75 mV"},{"name":"5 Hz 至 10 Hz","range":"120 V 至 330 V","cmc":"680 µV/V +75 mV"},{"name":"10 Hz 至 20 kHz","range":"120 V 至 330 V","cmc":"110 µV/V +8 mV"},{"name":"20 kHz 至 50 kHz","range":"120 V 至 330 V","cmc":"230 µV/V +8 mV"},{"name":"50 kHz 至 100 kHz","range":"120 V 至 330 V","cmc":"1 200 µV/V +12,5 mV"},{"name":"3 Hz 至 5 Hz","range":"330 V 至 1020 V","cmc":"1 900 µV/V +75 mV"},{"name":"5 Hz 至 10 Hz","range":"330 V 至 1020 V","cmc":"680 µV/V +75 mV"},{"name":"10 Hz 至 10 kHz","range":"330 V 至 1020 V","cmc":"110 µV/V +80 mV"}],"parameters_cs":[{"name":"3 Hz až 5 Hz","range":"1 mV až 12 mV","cmc":"1 900 µV/V +7 µV"},{"name":"5 Hz až 10 Hz","range":"1 mV až 12 mV","cmc":"680 µV/V +7 µV"},{"name":"10 Hz až 20 kHz","range":"1 mV až 12 mV","cmc":"120 µV/V +6 µV"},{"name":"20 kHz až 50 kHz","range":"1 mV až 12 mV","cmc":"290 µV/V +6 µV"},{"name":"50 kHz až 100 kHz","range":"1 mV až 12 mV","cmc":"1200 µV/V +15 µV"},{"name":"100 kHz až 500 kHz","range":"1 mV až 12 mV","cmc":"6 200 µV/V +30 µV"},{"name":"3 Hz až 5 Hz","range":"12 mV až 120 mV","cmc":"1 900 µV/V +7 µV"},{"name":"5 Hz až 10 Hz","range":"12 mV až 120 mV","cmc":"680 µV/V +7 µV"},{"name":"10 Hz až 20 kHz","range":"12 mV až 120 mV","cmc":"110 µV/V +6 µV"},{"name":"20 kHz až 50 kHz","range":"12 mV až 120 mV","cmc":"270 µV/V +8 µV"},{"name":"50 kHz až 100 kHz","range":"12 mV až 120 mV","cmc":"620 µV/V +20 µV"},{"name":"100 kHz až 500 kHz","range":"12 mV až 120 mV","cmc":"1 600 µV/V +30 µV"},{"name":"3 Hz až 5 Hz","range":"120 mV až 1,2 V","cmc":"1 900 µV/V +75 µV"},{"name":"5 Hz až 10 Hz","range":"120 mV až 1,2 V","cmc":"680 µV/V +70 µV"},{"name":"10 Hz až 40 Hz","range":"120 mV až 1,2 V","cmc":"110 µV/V +60 µV"},{"name":"40,01 Hz až 20 kHz","range":"120 mV až 1,2 V","cmc":"110 µV/V +8 µV"},{"name":"20 kHz až 50 kHz","range":"120 mV až 1,2 V","cmc":"230 µV/V +14 µV"},{"name":"50 kHz až 100 kHz","range":"120 mV až 1,2 V","cmc":"540 µV/V +40 µV"},{"name":"100 kHz až 500 kHz","range":"120 mV až 1,2 V","cmc":"1 500 µV/V +80 µV"},{"name":"3 Hz až 5 Hz","range":"1,2 V až 12 V","cmc":"1 900 µV/V +750 µV"},{"name":"5 Hz až 10 Hz","range":"1,2 V až 12 V","cmc":"680 µV/V +750 µV"},{"name":"10 Hz až 40 Hz","range":"1,2 V až 12 V","cmc":"110 µV/V +350 µV"},{"name":"40,01 Hz až 20 kHz","range":"1,2 V až 12 V","cmc":"110 µV/V +50 µV"},{"name":"20 kHz až 50 kHz","range":"1,2 V až 12 V","cmc":"230 µV/V +50 µV"},{"name":"50 kHz až 100 kHz","range":"1,2 V až 12 V","cmc":"540 µV/V +125 µV"},{"name":"100 kHz až 500 kHz","range":"1,2 V až 12 V","cmc":"1 600 µV/V +600 µV"},{"name":"3 Hz až 5 Hz","range":"12 V až 120 V","cmc":"1 900 µV/V +7 500 µV"},{"name":"5 Hz až 10 Hz","range":"12 V až 120 V","cmc":"680 µV/V +7 500 µV"},{"name":"10 Hz až 40 Hz","range":"12 V až 120 V","cmc":"110 µV/V +3 500 µV"},{"name":"40,01 Hz až 20 kHz","range":"12 V až 120 V","cmc":"110 µV/V +500 µV"},{"name":"20 kHz až 50 kHz","range":"12 V až 120 V","cmc":"230 µV/V +500 µV"},{"name":"50 kHz až 100 kHz","range":"12 V až 120 V","cmc":"540 µV/V +1 250 µV"},{"name":"100 kHz až 300 kHz (max. 70 V)","range":"12 V až 120 V","cmc":"1 600 µV/V +20 mV"},{"name":"3 Hz až 5 Hz","range":"120 V až 330 V","cmc":"1 900 µV/V +75 mV"},{"name":"5 Hz až 10 Hz","range":"120 V až 330 V","cmc":"680 µV/V +75 mV"},{"name":"10 Hz až 20 kHz","range":"120 V až 330 V","cmc":"110 µV/V +8 mV"},{"name":"20 kHz až 50 kHz","range":"120 V až 330 V","cmc":"230 µV/V +8 mV"},{"name":"50 kHz až 100 kHz","range":"120 V až 330 V","cmc":"1 200 µV/V +12,5 mV"},{"name":"3 Hz až 5 Hz","range":"330 V až 1020 V","cmc":"1 900 µV/V +75 mV"},{"name":"5 Hz až 10 Hz","range":"330 V až 1020 V","cmc":"680 µV/V +75 mV"},{"name":"10 Hz až 10 kHz","range":"330 V až 1020 V","cmc":"110 µV/V +80 mV"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation by a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation by a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n3 Hz do 5 Hz od 1 mV do 12 mV CMC 1 900 µV/V +7 µV\n5 Hz do 10 Hz od 1 mV do 12 mV CMC 680 µV/V +7 µV\n10 Hz do 20 kHz od 1 mV do 12 mV CMC 120 µV/V +6 µV\n20 kHz do 50 kHz od 1 mV do 12 mV CMC 290 µV/V +6 µV\n50 kHz do 100 kHz od 1 mV do 12 mV CMC 1200 µV/V +15 µV\n100 kHz do 500 kHz od 1 mV do 12 mV CMC 6 200 µV/V +30 µV\n3 Hz do 5 Hz od 12 mV do 120 mV CMC 1 900 µV/V +7 µV\n5 Hz do 10 Hz od 12 mV do 120 mV CMC 680 µV/V +7 µV\n10 Hz do 20 kHz od 12 mV do 120 mV CMC 110 µV/V +6 µV\n20 kHz do 50 kHz od 12 mV do 120 mV CMC 270 µV/V +8 µV\n50 kHz do 100 kHz od 12 mV do 120 mV CMC 620 µV/V +20 µV\n100 kHz do 500 kHz od 12 mV do 120 mV CMC 1 600 µV/V +30 µV\n3 Hz do 5 Hz od 120 mV do 1,2 V CMC 1 900 µV/V +75 µV\n5 Hz do 10 Hz od 120 mV do 1,2 V CMC 680 µV/V +70 µV\n10 Hz do 40 Hz od 120 mV do 1,2 V CMC 110 µV/V +60 µV\n40,01 Hz do 20 kHz od 120 mV do 1,2 V CMC 110 µV/V +8 µV\n20 kHz do 50 kHz od 120 mV do 1,2 V CMC 230 µV/V +14 µV\n50 kHz do 100 kHz od 120 mV do 1,2 V CMC 540 µV/V +40 µV\n100 kHz do 500 kHz od 120 mV do 1,2 V CMC 1 500 µV/V +80 µV\n3 Hz do 5 Hz od 1,2 V do 12 V CMC 1 900 µV/V +750 µV\n5 Hz do 10 Hz od 1,2 V do 12 V CMC 680 µV/V +750 µV\n10 Hz do 40 Hz od 1,2 V do 12 V CMC 110 µV/V +350 µV\n40,01 Hz do 20 kHz od 1,2 V do 12 V CMC 110 µV/V +50 µV\n20 kHz do 50 kHz od 1,2 V do 12 V CMC 230 µV/V +50 µV\n50 kHz do 100 kHz od 1,2 V do 12 V CMC 540 µV/V +125 µV\n100 kHz do 500 kHz od 1,2 V do 12 V CMC 1 600 µV/V +600 µV\n3 Hz do 5 Hz od 12 V do 120 V CMC 1 900 µV/V +7 500 µV\n5 Hz do 10 Hz od 12 V do 120 V CMC 680 µV/V +7 500 µV\n10 Hz do 40 Hz od 12 V do 120 V CMC 110 µV/V +3 500 µV\n40,01 Hz do 20 kHz od 12 V do 120 V CMC 110 µV/V +500 µV\n20 kHz do 50 kHz od 12 V do 120 V CMC 230 µV/V +500 µV\n50 kHz do 100 kHz od 12 V do 120 V CMC 540 µV/V +1 250 µV\n100 kHz do 300 kHz (maks. 70 V) od 12 V do 120 V CMC 1 600 µV/V +20 mV\n3 Hz do 5 Hz od 120 V do 330 V CMC 1 900 µV/V +75 mV\n5 Hz do 10 Hz od 120 V do 330 V CMC 680 µV/V +75 mV\n10 Hz do 20 kHz od 120 V do 330 V CMC 110 µV/V +8 mV\n20 kHz do 50 kHz od 120 V do 330 V CMC 230 µV/V +8 mV\n50 kHz do 100 kHz od 120 V do 330 V CMC 1 200 µV/V +12,5 mV\n3 Hz do 5 Hz od 330 V do 1020 V CMC 1 900 µV/V +75 mV\n5 Hz do 10 Hz od 330 V do 1020 V CMC 680 µV/V +75 mV\n10 Hz do 10 kHz od 330 V do 1020 V CMC 110 µV/V +80 mV\nBezpośrednie generowanie kalibratorem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / mierniki napięcia przemiennego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 3 Hz do 5 Hz od 1 mV do 12 mV CMC 1 900 µV/V +7 µV 5 Hz do 10 Hz od 1 mV do 12 mV CMC 680 µV/V +7 µV 10 Hz do 20 kHz od 1 mV do 12 mV CMC 120 µV/V +6 µV 20 kHz do 50 kHz od 1 mV do 12 mV CMC 290 µV/V +6 µV 50 kHz do 100 kHz od 1 mV do 12 mV CMC 1200 µV/V +15 µV 100 kHz do 500 kHz od 1 mV do 12 mV CMC 6 200 µV/V +30 µV 3 Hz do 5 Hz od 12 mV do 120 mV CMC 1 900 µV/V +7 µV 5 Hz do 10 Hz od 12 mV do 120 mV CMC 680 µV/V +7 µV 10 Hz do 20 kHz od 12 mV do 120 mV CMC 110 µV/V +6 µV 20 kHz do 50 kHz od 12 mV do 120 mV CMC 270 µV/V +8 µV 50 kHz do 100 kHz od 12 mV do 120 mV CMC 620 µV/V +20 µV 100 kHz do 500 kHz od 12 mV do 120 mV CMC 1 600 µV/V +30 µV 3 Hz do 5 Hz od 120 mV do 1,2 V CMC 1 900 µV/V +75 µV 5 Hz do 10 Hz od 120 mV do 1,2 V CMC 680 µV/V +70 µV 10 Hz do 40 Hz od 120 mV do 1,2 V CMC 110 µV/V +60 µV 40,01 Hz do 20 kHz od 120 mV do 1,2 V CMC 110 µV/V +8 µV 20 kHz do 50 kHz od 120 mV do 1,2 V CMC 230 µV/V +14 µV 50 kHz do 100 kHz od 120 mV do 1,2 V CMC 540 µV/V +40 µV 100 kHz do 500 kHz od 120 mV do 1,2 V CMC 1 500 µV/V +80 µV 3 Hz do 5 Hz od 1,2 V do 12 V CMC 1 900 µV/V +750 µV 5 Hz do 10 Hz od 1,2 V do 12 V CMC 680 µV/V +750 µV 10 Hz do 40 Hz od 1,2 V do 12 V CMC 110 µV/V +350 µV 40,01 Hz do 20 kHz od 1,2 V do 12 V CMC 110 µV/V +50 µV 20 kHz do 50 kHz od 1,2 V do 12 V CMC 230 µV/V +50 µV 50 kHz do 100 kHz od 1,2 V do 12 V CMC 540 µV/V +125 µV 100 kHz do 500 kHz od 1,2 V do 12 V CMC 1 600 µV/V +600 µV 3 Hz do 5 Hz od 12 V do 120 V CMC 1 900 µV/V +7 500 µV 5 Hz do 10 Hz od 12 V do 120 V CMC 680 µV/V +7 500 µV 10 Hz do 40 Hz od 12 V do 120 V CMC 110 µV/V +3 500 µV 40,01 Hz do 20 kHz od 12 V do 120 V CMC 110 µV/V +500 µV 20 kHz do 50 kHz od 12 V do 120 V CMC 230 µV/V +500 µV 50 kHz do 100 kHz od 12 V do 120 V CMC 540 µV/V +1 250 µV 100 kHz do 300 kHz (maks. 70 V) od 12 V do 120 V CMC 1 600 µV/V +20 mV 3 Hz do 5 Hz od 120 V do 330 V CMC 1 900 µV/V +75 mV 5 Hz do 10 Hz od 120 V do 330 V CMC 680 µV/V +75 mV 10 Hz do 20 kHz od 120 V do 330 V CMC 110 µV/V +8 mV 20 kHz do 50 kHz od 120 V do 330 V CMC 230 µV/V +8 mV 50 kHz do 100 kHz od 120 V do 330 V CMC 1 200 µV/V +12,5 mV 3 Hz do 5 Hz od 330 V do 1020 V CMC 1 900 µV/V +75 mV 5 Hz do 10 Hz od 330 V do 1020 V CMC 680 µV/V +75 mV 10 Hz do 10 kHz od 330 V do 1020 V CMC 110 µV/V +80 mV Střídavé napětí / měřidla střídavého napětí, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 3 Hz až 5 Hz 1 mV až 12 mV CMC 1 900 µV/V +7 µV 5 Hz až 10 Hz 1 mV až 12 mV CMC 680 µV/V +7 µV 10 Hz až 20 kHz 1 mV až 12 mV CMC 120 µV/V +6 µV 20 kHz až 50 kHz 1 mV až 12 mV CMC 290 µV/V +6 µV 50 kHz až 100 kHz 1 mV až 12 mV CMC 1200 µV/V +15 µV 100 kHz až 500 kHz 1 mV až 12 mV CMC 6 200 µV/V +30 µV 3 Hz až 5 Hz 12 mV až 120 mV CMC 1 900 µV/V +7 µV 5 Hz až 10 Hz 12 mV až 120 mV CMC 680 µV/V +7 µV 10 Hz až 20 kHz 12 mV až 120 mV CMC 110 µV/V +6 µV 20 kHz až 50 kHz 12 mV až 120 mV CMC 270 µV/V +8 µV 50 kHz až 100 kHz 12 mV až 120 mV CMC 620 µV/V +20 µV 100 kHz až 500 kHz 12 mV až 120 mV CMC 1 600 µV/V +30 µV 3 Hz až 5 Hz 120 mV až 1,2 V CMC 1 900 µV/V +75 µV 5 Hz až 10 Hz 120 mV až 1,2 V CMC 680 µV/V +70 µV 10 Hz až 40 Hz 120 mV až 1,2 V CMC 110 µV/V +60 µV 40,01 Hz až 20 kHz 120 mV až 1,2 V CMC 110 µV/V +8 µV 20 kHz až 50 kHz 120 mV až 1,2 V CMC 230 µV/V +14 µV 50 kHz až 100 kHz 120 mV až 1,2 V CMC 540 µV/V +40 µV 100 kHz až 500 kHz 120 mV až 1,2 V CMC 1 500 µV/V +80 µV 3 Hz až 5 Hz 1,2 V až 12 V CMC 1 900 µV/V +750 µV 5 Hz až 10 Hz 1,2 V až 12 V CMC 680 µV/V +750 µV 10 Hz až 40 Hz 1,2 V až 12 V CMC 110 µV/V +350 µV 40,01 Hz až 20 kHz 1,2 V až 12 V CMC 110 µV/V +50 µV 20 kHz až 50 kHz 1,2 V až 12 V CMC 230 µV/V +50 µV 50 kHz až 100 kHz 1,2 V až 12 V CMC 540 µV/V +125 µV 100 kHz až 500 kHz 1,2 V až 12 V CMC 1 600 µV/V +600 µV 3 Hz až 5 Hz 12 V až 120 V CMC 1 900 µV/V +7 500 µV 5 Hz až 10 Hz 12 V až 120 V CMC 680 µV/V +7 500 µV 10 Hz až 40 Hz 12 V až 120 V CMC 110 µV/V +3 500 µV 40,01 Hz až 20 kHz 12 V až 120 V CMC 110 µV/V +500 µV 20 kHz až 50 kHz 12 V až 120 V CMC 230 µV/V +500 µV 50 kHz až 100 kHz 12 V až 120 V CMC 540 µV/V +1 250 µV 100 kHz až 300 kHz (max. 70 V) 12 V až 120 V CMC 1 600 µV/V +20 mV 3 Hz až 5 Hz 120 V až 330 V CMC 1 900 µV/V +75 mV 5 Hz až 10 Hz 120 V až 330 V CMC 680 µV/V +75 mV 10 Hz až 20 kHz 120 V až 330 V CMC 110 µV/V +8 mV 20 kHz až 50 kHz 120 V až 330 V CMC 230 µV/V +8 mV 50 kHz až 100 kHz 120 V až 330 V CMC 1 200 µV/V +12,5 mV 3 Hz až 5 Hz 330 V až 1020 V CMC 1 900 µV/V +75 mV 5 Hz až 10 Hz 330 V až 1020 V CMC 680 µV/V +75 mV 10 Hz až 10 kHz 330 V až 1020 V CMC 110 µV/V +80 mV VKP01/05 VKP02/05 Napiecie przemienne / mierniki napiecia przemiennego, kalibratory, multimetry, mierniki cegowe, mierniki do badan instalacji, testery wielofunkcyjne, mierniki rezystancji uziemien, mierniki uziemien, testery elektronarzedzi Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 3 Hz do 5 Hz od 1 mV do 12 mV CMC 1 900 µV/V +7 µV 5 Hz do 10 Hz od 1 mV do 12 mV CMC 680 µV/V +7 µV 10 Hz do 20 kHz od 1 mV do 12 mV CMC 120 µV/V +6 µV 20 kHz do 50 kHz od 1 mV do 12 mV CMC 290 µV/V +6 µV 50 kHz do 100 kHz od 1 mV do 12 mV CMC 1200 µV/V +15 µV 100 kHz do 500 kHz od 1 mV do 12 mV CMC 6 200 µV/V +30 µV 3 Hz do 5 Hz od 12 mV do 120 mV CMC 1 900 µV/V +7 µV 5 Hz do 10 Hz od 12 mV do 120 mV CMC 680 µV/V +7 µV 10 Hz do 20 kHz od 12 mV do 120 mV CMC 110 µV/V +6 µV 20 kHz do 50 kHz od 12 mV do 120 mV CMC 270 µV/V +8 µV 50 kHz do 100 kHz od 12 mV do 120 mV CMC 620 µV/V +20 µV 100 kHz do 500 kHz od 12 mV do 120 mV CMC 1 600 µV/V +30 µV 3 Hz do 5 Hz od 120 mV do 1,2 V CMC 1 900 µV/V +75 µV 5 Hz do 10 Hz od 120 mV do 1,2 V CMC 680 µV/V +70 µV 10 Hz do 40 Hz od 120 mV do 1,2 V CMC 110 µV/V +60 µV 40,01 Hz do 20 kHz od 120 mV do 1,2 V CMC 110 µV/V +8 µV 20 kHz do 50 kHz od 120 mV do 1,2 V CMC 230 µV/V +14 µV 50 kHz do 100 kHz od 120 mV do 1,2 V CMC 540 µV/V +40 µV 100 kHz do 500 kHz od 120 mV do 1,2 V CMC 1 500 µV/V +80 µV 3 Hz do 5 Hz od 1,2 V do 12 V CMC 1 900 µV/V +750 µV 5 Hz do 10 Hz od 1,2 V do 12 V CMC 680 µV/V +750 µV 10 Hz do 40 Hz od 1,2 V do 12 V CMC 110 µV/V +350 µV 40,01 Hz do 20 kHz od 1,2 V do 12 V CMC 110 µV/V +50 µV 20 kHz do 50 kHz od 1,2 V do 12 V CMC 230 µV/V +50 µV 50 kHz do 100 kHz od 1,2 V do 12 V CMC 540 µV/V +125 µV 100 kHz do 500 kHz od 1,2 V do 12 V CMC 1 600 µV/V +600 µV 3 Hz do 5 Hz od 12 V do 120 V CMC 1 900 µV/V +7 500 µV 5 Hz do 10 Hz od 12 V do 120 V CMC 680 µV/V +7 500 µV 10 Hz do 40 Hz od 12 V do 120 V CMC 110 µV/V +3 500 µV 40,01 Hz do 20 kHz od 12 V do 120 V CMC 110 µV/V +500 µV 20 kHz do 50 kHz od 12 V do 120 V CMC 230 µV/V +500 µV 50 kHz do 100 kHz od 12 V do 120 V CMC 540 µV/V +1 250 µV 100 kHz do 300 kHz (maks. 70 V) od 12 V do 120 V CMC 1 600 µV/V +20 mV 3 Hz do 5 Hz od 120 V do 330 V CMC 1 900 µV/V +75 mV 5 Hz do 10 Hz od 120 V do 330 V CMC 680 µV/V +75 mV 10 Hz do 20 kHz od 120 V do 330 V CMC 110 µV/V +8 mV 20 kHz do 50 kHz od 120 V do 330 V CMC 230 µV/V +8 mV 50 kHz do 100 kHz od 120 V do 330 V CMC 1 200 µV/V +12,5 mV 3 Hz do 5 Hz od 330 V do 1020 V CMC 1 900 µV/V +75 mV 5 Hz do 10 Hz od 330 V do 1020 V CMC 680 µV/V +75 mV 10 Hz do 10 kHz od 330 V do 1020 V CMC 110 µV/V +80 mV Stridave napeti / meridla stridaveho napeti, kalibratory, multimetry, klestova meridla, revizni meridla, multifunkcni testery, merice zemniho odporu, meridla uzemneni, testery rucniho naradi Kalibrace – elektricke veliciny Prime generovani kalibratorem 3 Hz az 5 Hz 1 mV az 12 mV CMC 1 900 µV/V +7 µV 5 Hz az 10 Hz 1 mV az 12 mV CMC 680 µV/V +7 µV 10 Hz az 20 kHz 1 mV az 12 mV CMC 120 µV/V +6 µV 20 kHz az 50 kHz 1 mV az 12 mV CMC 290 µV/V +6 µV 50 kHz az 100 kHz 1 mV az 12 mV CMC 1200 µV/V +15 µV 100 kHz az 500 kHz 1 mV az 12 mV CMC 6 200 µV/V +30 µV 3 Hz az 5 Hz 12 mV az 120 mV CMC 1 900 µV/V +7 µV 5 Hz az 10 Hz 12 mV az 120 mV CMC 680 µV/V +7 µV 10 Hz az 20 kHz 12 mV az 120 mV CMC 110 µV/V +6 µV 20 kHz az 50 kHz 12 mV az 120 mV CMC 270 µV/V +8 µV 50 kHz az 100 kHz 12 mV az 120 mV CMC 620 µV/V +20 µV 100 kHz az 500 kHz 12 mV az 120 mV CMC 1 600 µV/V +30 µV 3 Hz az 5 Hz 120 mV az 1,2 V CMC 1 900 µV/V +75 µV 5 Hz az 10 Hz 120 mV az 1,2 V CMC 680 µV/V +70 µV 10 Hz az 40 Hz 120 mV az 1,2 V CMC 110 µV/V +60 µV 40,01 Hz az 20 kHz 120 mV az 1,2 V CMC 110 µV/V +8 µV 20 kHz az 50 kHz 120 mV az 1,2 V CMC 230 µV/V +14 µV 50 kHz az 100 kHz 120 mV az 1,2 V CMC 540 µV/V +40 µV 100 kHz az 500 kHz 120 mV az 1,2 V CMC 1 500 µV/V +80 µV 3 Hz az 5 Hz 1,2 V az 12 V CMC 1 900 µV/V +750 µV 5 Hz az 10 Hz 1,2 V az 12 V CMC 680 µV/V +750 µV 10 Hz az 40 Hz 1,2 V az 12 V CMC 110 µV/V +350 µV 40,01 Hz az 20 kHz 1,2 V az 12 V CMC 110 µV/V +50 µV 20 kHz az 50 kHz 1,2 V az 12 V CMC 230 µV/V +50 µV 50 kHz az 100 kHz 1,2 V az 12 V CMC 540 µV/V +125 µV 100 kHz az 500 kHz 1,2 V az 12 V CMC 1 600 µV/V +600 µV 3 Hz az 5 Hz 12 V az 120 V CMC 1 900 µV/V +7 500 µV 5 Hz az 10 Hz 12 V az 120 V CMC 680 µV/V +7 500 µV 10 Hz az 40 Hz 12 V az 120 V CMC 110 µV/V +3 500 µV 40,01 Hz az 20 kHz 12 V az 120 V CMC 110 µV/V +500 µV 20 kHz az 50 kHz 12 V az 120 V CMC 230 µV/V +500 µV 50 kHz az 100 kHz 12 V az 120 V CMC 540 µV/V +1 250 µV 100 kHz az 300 kHz (max. 70 V) 12 V az 120 V CMC 1 600 µV/V +20 mV 3 Hz az 5 Hz 120 V az 330 V CMC 1 900 µV/V +75 mV 5 Hz az 10 Hz 120 V az 330 V CMC 680 µV/V +75 mV 10 Hz az 20 kHz 120 V az 330 V CMC 110 µV/V +8 mV 20 kHz az 50 kHz 120 V az 330 V CMC 230 µV/V +8 mV 50 kHz az 100 kHz 120 V az 330 V CMC 1 200 µV/V +12,5 mV 3 Hz az 5 Hz 330 V az 1020 V CMC 1 900 µV/V +75 mV 5 Hz az 10 Hz 330 V az 1020 V CMC 680 µV/V +75 mV 10 Hz az 10 kHz 330 V az 1020 V CMC 110 µV/V +80 mV VKP01/05 VKP02/05","search_en":"AC voltage / AC voltage meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers Calibration – electrical quantities Direct generation by a calibrator 3 Hz to 5 Hz 1 mV to 12 mV CMC 1 900 µV/V +7 µV 5 Hz to 10 Hz 1 mV to 12 mV CMC 680 µV/V +7 µV 10 Hz to 20 kHz 1 mV to 12 mV CMC 120 µV/V +6 µV 20 kHz to 50 kHz 1 mV to 12 mV CMC 290 µV/V +6 µV 50 kHz to 100 kHz 1 mV to 12 mV CMC 1200 µV/V +15 µV 100 kHz to 500 kHz 1 mV to 12 mV CMC 6 200 µV/V +30 µV 3 Hz to 5 Hz 12 mV to 120 mV CMC 1 900 µV/V +7 µV 5 Hz to 10 Hz 12 mV to 120 mV CMC 680 µV/V +7 µV 10 Hz to 20 kHz 12 mV to 120 mV CMC 110 µV/V +6 µV 20 kHz to 50 kHz 12 mV to 120 mV CMC 270 µV/V +8 µV 50 kHz to 100 kHz 12 mV to 120 mV CMC 620 µV/V +20 µV 100 kHz to 500 kHz 12 mV to 120 mV CMC 1 600 µV/V +30 µV 3 Hz to 5 Hz 120 mV to 1,2 V CMC 1 900 µV/V +75 µV 5 Hz to 10 Hz 120 mV to 1,2 V CMC 680 µV/V +70 µV 10 Hz to 40 Hz 120 mV to 1,2 V CMC 110 µV/V +60 µV 40,01 Hz to 20 kHz 120 mV to 1,2 V CMC 110 µV/V +8 µV 20 kHz to 50 kHz 120 mV to 1,2 V CMC 230 µV/V +14 µV 50 kHz to 100 kHz 120 mV to 1,2 V CMC 540 µV/V +40 µV 100 kHz to 500 kHz 120 mV to 1,2 V CMC 1 500 µV/V +80 µV 3 Hz to 5 Hz 1,2 V to 12 V CMC 1 900 µV/V +750 µV 5 Hz to 10 Hz 1,2 V to 12 V CMC 680 µV/V +750 µV 10 Hz to 40 Hz 1,2 V to 12 V CMC 110 µV/V +350 µV 40,01 Hz to 20 kHz 1,2 V to 12 V CMC 110 µV/V +50 µV 20 kHz to 50 kHz 1,2 V to 12 V CMC 230 µV/V +50 µV 50 kHz to 100 kHz 1,2 V to 12 V CMC 540 µV/V +125 µV 100 kHz to 500 kHz 1,2 V to 12 V CMC 1 600 µV/V +600 µV 3 Hz to 5 Hz 12 V to 120 V CMC 1 900 µV/V +7 500 µV 5 Hz to 10 Hz 12 V to 120 V CMC 680 µV/V +7 500 µV 10 Hz to 40 Hz 12 V to 120 V CMC 110 µV/V +3 500 µV 40,01 Hz to 20 kHz 12 V to 120 V CMC 110 µV/V +500 µV 20 kHz to 50 kHz 12 V to 120 V CMC 230 µV/V +500 µV 50 kHz to 100 kHz 12 V to 120 V CMC 540 µV/V +1 250 µV 100 kHz to 300 kHz (max. 70 V) 12 V to 120 V CMC 1 600 µV/V +20 mV 3 Hz to 5 Hz 120 V to 330 V CMC 1 900 µV/V +75 mV 5 Hz to 10 Hz 120 V to 330 V CMC 680 µV/V +75 mV 10 Hz to 20 kHz 120 V to 330 V CMC 110 µV/V +8 mV 20 kHz to 50 kHz 120 V to 330 V CMC 230 µV/V +8 mV 50 kHz to 100 kHz 120 V to 330 V CMC 1 200 µV/V +12,5 mV 3 Hz to 5 Hz 330 V to 1020 V CMC 1 900 µV/V +75 mV 5 Hz to 10 Hz 330 V to 1020 V CMC 680 µV/V +75 mV 10 Hz to 10 kHz 330 V to 1020 V CMC 110 µV/V +80 mV VKP01/05 VKP02/05","search_zh":"交流电压 / 交流电压表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪 校准 – 电学量 用校准器直接产生 3 Hz 至 5 Hz 1 mV 至 12 mV CMC 1 900 µV/V +7 µV 5 Hz 至 10 Hz 1 mV 至 12 mV CMC 680 µV/V +7 µV 10 Hz 至 20 kHz 1 mV 至 12 mV CMC 120 µV/V +6 µV 20 kHz 至 50 kHz 1 mV 至 12 mV CMC 290 µV/V +6 µV 50 kHz 至 100 kHz 1 mV 至 12 mV CMC 1200 µV/V +15 µV 100 kHz 至 500 kHz 1 mV 至 12 mV CMC 6 200 µV/V +30 µV 3 Hz 至 5 Hz 12 mV 至 120 mV CMC 1 900 µV/V +7 µV 5 Hz 至 10 Hz 12 mV 至 120 mV CMC 680 µV/V +7 µV 10 Hz 至 20 kHz 12 mV 至 120 mV CMC 110 µV/V +6 µV 20 kHz 至 50 kHz 12 mV 至 120 mV CMC 270 µV/V +8 µV 50 kHz 至 100 kHz 12 mV 至 120 mV CMC 620 µV/V +20 µV 100 kHz 至 500 kHz 12 mV 至 120 mV CMC 1 600 µV/V +30 µV 3 Hz 至 5 Hz 120 mV 至 1,2 V CMC 1 900 µV/V +75 µV 5 Hz 至 10 Hz 120 mV 至 1,2 V CMC 680 µV/V +70 µV 10 Hz 至 40 Hz 120 mV 至 1,2 V CMC 110 µV/V +60 µV 40,01 Hz 至 20 kHz 120 mV 至 1,2 V CMC 110 µV/V +8 µV 20 kHz 至 50 kHz 120 mV 至 1,2 V CMC 230 µV/V +14 µV 50 kHz 至 100 kHz 120 mV 至 1,2 V CMC 540 µV/V +40 µV 100 kHz 至 500 kHz 120 mV 至 1,2 V CMC 1 500 µV/V +80 µV 3 Hz 至 5 Hz 1,2 V 至 12 V CMC 1 900 µV/V +750 µV 5 Hz 至 10 Hz 1,2 V 至 12 V CMC 680 µV/V +750 µV 10 Hz 至 40 Hz 1,2 V 至 12 V CMC 110 µV/V +350 µV 40,01 Hz 至 20 kHz 1,2 V 至 12 V CMC 110 µV/V +50 µV 20 kHz 至 50 kHz 1,2 V 至 12 V CMC 230 µV/V +50 µV 50 kHz 至 100 kHz 1,2 V 至 12 V CMC 540 µV/V +125 µV 100 kHz 至 500 kHz 1,2 V 至 12 V CMC 1 600 µV/V +600 µV 3 Hz 至 5 Hz 12 V 至 120 V CMC 1 900 µV/V +7 500 µV 5 Hz 至 10 Hz 12 V 至 120 V CMC 680 µV/V +7 500 µV 10 Hz 至 40 Hz 12 V 至 120 V CMC 110 µV/V +3 500 µV 40,01 Hz 至 20 kHz 12 V 至 120 V CMC 110 µV/V +500 µV 20 kHz 至 50 kHz 12 V 至 120 V CMC 230 µV/V +500 µV 50 kHz 至 100 kHz 12 V 至 120 V CMC 540 µV/V +1 250 µV 100 kHz 至 300 kHz（最大 70 V） 12 V 至 120 V CMC 1 600 µV/V +20 mV 3 Hz 至 5 Hz 120 V 至 330 V CMC 1 900 µV/V +75 mV 5 Hz 至 10 Hz 120 V 至 330 V CMC 680 µV/V +75 mV 10 Hz 至 20 kHz 120 V 至 330 V CMC 110 µV/V +8 mV 20 kHz 至 50 kHz 120 V 至 330 V CMC 230 µV/V +8 mV 50 kHz 至 100 kHz 120 V 至 330 V CMC 1 200 µV/V +12,5 mV 3 Hz 至 5 Hz 330 V 至 1020 V CMC 1 900 µV/V +75 mV 5 Hz 至 10 Hz 330 V 至 1020 V CMC 680 µV/V +75 mV 10 Hz 至 10 kHz 330 V 至 1020 V CMC 110 µV/V +80 mV VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"df73a77986d797a16ed3ebb4","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / źródła napięcia przemiennego","test_object_en":"AC voltage / AC voltage sources","test_object_zh":"交流电压 / 交流电压源","test_object_cs":"Střídavé napětí / zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 20 kHz","range":"od 1 mV do 100 mV","cmc":"0,05 % +40 µV"},{"name":"20 kHz do 50 kHz","range":"od 1 mV do 100 mV","cmc":"0,11 % +50 µV"},{"name":"50 kHz do 100 kHz","range":"od 1 mV do 100 mV","cmc":"0,6 % +80 µV"},{"name":"100 kHz do 300 kHz","range":"od 1 mV do 100 mV","cmc":"4 % +0,5 mV"},{"name":"10 Hz do 20 kHz","range":"od 100 mV do 1 V","cmc":"0,05 % +0,3 mV"},{"name":"20 kHz do 50 kHz","range":"od 100 mV do 1 V","cmc":"0,11 % +0,5 mV"},{"name":"50 kHz do 100 kHz","range":"od 100 mV do 1 V","cmc":"0,6 % +0,8 mV"},{"name":"100 kHz do 300 kHz","range":"od 100 mV do 1 V","cmc":"4 % +5 mV"},{"name":"10 Hz do 20 kHz","range":"od 1 V do 10 V","cmc":"0,05 % +3 mV"},{"name":"20 kHz do 50 kHz","range":"od 1 V do 10 V","cmc":"0,11 % +5 mV"},{"name":"50 kHz do 100 kHz","range":"od 1 V do 10 V","cmc":"0,6 % +8 mV"},{"name":"100 kHz do 300 kHz","range":"od 1 V do 10 V","cmc":"4 % +50 mV"},{"name":"10 Hz do 20 kHz","range":"od 10 V do 100 V","cmc":"0,05 % +30 mV"},{"name":"20 kHz do 50 kHz","range":"od 10 V do 100 V","cmc":"0,11 % +50 mV"},{"name":"50 kHz do 100 kHz","range":"od 10 V do 100 V","cmc":"0,6 % +80 mV"},{"name":"100 kHz do 300 kHz","range":"od 10 V do 100 V","cmc":"4 % +0,5 V"},{"name":"10 Hz do 20 kHz","range":"od 100 V do 1 kV","cmc":"0,05 % +0,3 V"},{"name":"20 kHz do 50 kHz","range":"od 100 V do 1 kV","cmc":"0,11 % +0,5 V"},{"name":"50 kHz do 100 kHz (maks. 8.10⁷ VHz)","range":"od 100 V do 1 kV","cmc":"0,6 % +0,8 V"},{"name":"100 kHz do 300 kHz (maks. 8.10⁷ VHz)","range":"od 100 V do 1 kV","cmc":"4 % +5 V"}],"parameters_en":[{"name":"10 Hz to 20 kHz","range":"1 mV to 100 mV","cmc":"0,05 % +40 µV"},{"name":"20 kHz to 50 kHz","range":"1 mV to 100 mV","cmc":"0,11 % +50 µV"},{"name":"50 kHz to 100 kHz","range":"1 mV to 100 mV","cmc":"0,6 % +80 µV"},{"name":"100 kHz to 300 kHz","range":"1 mV to 100 mV","cmc":"4 % +0,5 mV"},{"name":"10 Hz to 20 kHz","range":"100 mV to 1 V","cmc":"0,05 % +0,3 mV"},{"name":"20 kHz to 50 kHz","range":"100 mV to 1 V","cmc":"0,11 % +0,5 mV"},{"name":"50 kHz to 100 kHz","range":"100 mV to 1 V","cmc":"0,6 % +0,8 mV"},{"name":"100 kHz to 300 kHz","range":"100 mV to 1 V","cmc":"4 % +5 mV"},{"name":"10 Hz to 20 kHz","range":"1 V to 10 V","cmc":"0,05 % +3 mV"},{"name":"20 kHz to 50 kHz","range":"1 V to 10 V","cmc":"0,11 % +5 mV"},{"name":"50 kHz to 100 kHz","range":"1 V to 10 V","cmc":"0,6 % +8 mV"},{"name":"100 kHz to 300 kHz","range":"1 V to 10 V","cmc":"4 % +50 mV"},{"name":"10 Hz to 20 kHz","range":"10 V to 100 V","cmc":"0,05 % +30 mV"},{"name":"20 kHz to 50 kHz","range":"10 V to 100 V","cmc":"0,11 % +50 mV"},{"name":"50 kHz to 100 kHz","range":"10 V to 100 V","cmc":"0,6 % +80 mV"},{"name":"100 kHz to 300 kHz","range":"10 V to 100 V","cmc":"4 % +0,5 V"},{"name":"10 Hz to 20 kHz","range":"100 V to 1 kV","cmc":"0,05 % +0,3 V"},{"name":"20 kHz to 50 kHz","range":"100 V to 1 kV","cmc":"0,11 % +0,5 V"},{"name":"50 kHz to 100 kHz (max. 8.10⁷ VHz)","range":"100 V to 1 kV","cmc":"0,6 % +0,8 V"},{"name":"100 kHz to 300 kHz (max. 8.10⁷ VHz)","range":"100 V to 1 kV","cmc":"4 % +5 V"}],"parameters_zh":[{"name":"10 Hz 至 20 kHz","range":"1 mV 至 100 mV","cmc":"0,05 % +40 µV"},{"name":"20 kHz 至 50 kHz","range":"1 mV 至 100 mV","cmc":"0,11 % +50 µV"},{"name":"50 kHz 至 100 kHz","range":"1 mV 至 100 mV","cmc":"0,6 % +80 µV"},{"name":"100 kHz 至 300 kHz","range":"1 mV 至 100 mV","cmc":"4 % +0,5 mV"},{"name":"10 Hz 至 20 kHz","range":"100 mV 至 1 V","cmc":"0,05 % +0,3 mV"},{"name":"20 kHz 至 50 kHz","range":"100 mV 至 1 V","cmc":"0,11 % +0,5 mV"},{"name":"50 kHz 至 100 kHz","range":"100 mV 至 1 V","cmc":"0,6 % +0,8 mV"},{"name":"100 kHz 至 300 kHz","range":"100 mV 至 1 V","cmc":"4 % +5 mV"},{"name":"10 Hz 至 20 kHz","range":"1 V 至 10 V","cmc":"0,05 % +3 mV"},{"name":"20 kHz 至 50 kHz","range":"1 V 至 10 V","cmc":"0,11 % +5 mV"},{"name":"50 kHz 至 100 kHz","range":"1 V 至 10 V","cmc":"0,6 % +8 mV"},{"name":"100 kHz 至 300 kHz","range":"1 V 至 10 V","cmc":"4 % +50 mV"},{"name":"10 Hz 至 20 kHz","range":"10 V 至 100 V","cmc":"0,05 % +30 mV"},{"name":"20 kHz 至 50 kHz","range":"10 V 至 100 V","cmc":"0,11 % +50 mV"},{"name":"50 kHz 至 100 kHz","range":"10 V 至 100 V","cmc":"0,6 % +80 mV"},{"name":"100 kHz 至 300 kHz","range":"10 V 至 100 V","cmc":"4 % +0,5 V"},{"name":"10 Hz 至 20 kHz","range":"100 V 至 1 kV","cmc":"0,05 % +0,3 V"},{"name":"20 kHz 至 50 kHz","range":"100 V 至 1 kV","cmc":"0,11 % +0,5 V"},{"name":"50 kHz 至 100 kHz（最大 8.10⁷ VHz）","range":"100 V 至 1 kV","cmc":"0,6 % +0,8 V"},{"name":"100 kHz 至 300 kHz（最大 8.10⁷ VHz）","range":"100 V 至 1 kV","cmc":"4 % +5 V"}],"parameters_cs":[{"name":"10 Hz až 20 kHz","range":"1 mV až 100 mV","cmc":"0,05 % +40 µV"},{"name":"20 kHz až 50 kHz","range":"1 mV až 100 mV","cmc":"0,11 % +50 µV"},{"name":"50 kHz až 100 kHz","range":"1 mV až 100 mV","cmc":"0,6 % +80 µV"},{"name":"100 kHz až 300 kHz","range":"1 mV až 100 mV","cmc":"4 % +0,5 mV"},{"name":"10 Hz až 20 kHz","range":"100 mV až 1 V","cmc":"0,05 % +0,3 mV"},{"name":"20 kHz až 50 kHz","range":"100 mV až 1 V","cmc":"0,11 % +0,5 mV"},{"name":"50 kHz až 100 kHz","range":"100 mV až 1 V","cmc":"0,6 % +0,8 mV"},{"name":"100 kHz až 300 kHz","range":"100 mV až 1 V","cmc":"4 % +5 mV"},{"name":"10 Hz až 20 kHz","range":"1 V až 10 V","cmc":"0,05 % +3 mV"},{"name":"20 kHz až 50 kHz","range":"1 V až 10 V","cmc":"0,11 % +5 mV"},{"name":"50 kHz až 100 kHz","range":"1 V až 10 V","cmc":"0,6 % +8 mV"},{"name":"100 kHz až 300 kHz","range":"1 V až 10 V","cmc":"4 % +50 mV"},{"name":"10 Hz až 20 kHz","range":"10 V až 100 V","cmc":"0,05 % +30 mV"},{"name":"20 kHz až 50 kHz","range":"10 V až 100 V","cmc":"0,11 % +50 mV"},{"name":"50 kHz až 100 kHz","range":"10 V až 100 V","cmc":"0,6 % +80 mV"},{"name":"100 kHz až 300 kHz","range":"10 V až 100 V","cmc":"4 % +0,5 V"},{"name":"10 Hz až 20 kHz","range":"100 V až 1 kV","cmc":"0,05 % +0,3 V"},{"name":"20 kHz až 50 kHz","range":"100 V až 1 kV","cmc":"0,11 % +0,5 V"},{"name":"50 kHz až 100 kHz (max. 8.10⁷ VHz)","range":"100 V až 1 kV","cmc":"0,6 % +0,8 V"},{"name":"100 kHz až 300 kHz (max. 8.10⁷ VHz)","range":"100 V až 1 kV","cmc":"4 % +5 V"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement by a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement by a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 20 kHz od 1 mV do 100 mV CMC 0,05 % +40 µV\n20 kHz do 50 kHz od 1 mV do 100 mV CMC 0,11 % +50 µV\n50 kHz do 100 kHz od 1 mV do 100 mV CMC 0,6 % +80 µV\n100 kHz do 300 kHz od 1 mV do 100 mV CMC 4 % +0,5 mV\n10 Hz do 20 kHz od 100 mV do 1 V CMC 0,05 % +0,3 mV\n20 kHz do 50 kHz od 100 mV do 1 V CMC 0,11 % +0,5 mV\n50 kHz do 100 kHz od 100 mV do 1 V CMC 0,6 % +0,8 mV\n100 kHz do 300 kHz od 100 mV do 1 V CMC 4 % +5 mV\n10 Hz do 20 kHz od 1 V do 10 V CMC 0,05 % +3 mV\n20 kHz do 50 kHz od 1 V do 10 V CMC 0,11 % +5 mV\n50 kHz do 100 kHz od 1 V do 10 V CMC 0,6 % +8 mV\n100 kHz do 300 kHz od 1 V do 10 V CMC 4 % +50 mV\n10 Hz do 20 kHz od 10 V do 100 V CMC 0,05 % +30 mV\n20 kHz do 50 kHz od 10 V do 100 V CMC 0,11 % +50 mV\n50 kHz do 100 kHz od 10 V do 100 V CMC 0,6 % +80 mV\n100 kHz do 300 kHz od 10 V do 100 V CMC 4 % +0,5 V\n10 Hz do 20 kHz od 100 V do 1 kV CMC 0,05 % +0,3 V\n20 kHz do 50 kHz od 100 V do 1 kV CMC 0,11 % +0,5 V\n50 kHz do 100 kHz (maks. 8.10⁷ VHz) od 100 V do 1 kV CMC 0,6 % +0,8 V\n100 kHz do 300 kHz (maks. 8.10⁷ VHz) od 100 V do 1 kV CMC 4 % +5 V\nPomiar bezpośredni multimetrem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 10 Hz do 20 kHz od 1 mV do 100 mV CMC 0,05 % +40 µV 20 kHz do 50 kHz od 1 mV do 100 mV CMC 0,11 % +50 µV 50 kHz do 100 kHz od 1 mV do 100 mV CMC 0,6 % +80 µV 100 kHz do 300 kHz od 1 mV do 100 mV CMC 4 % +0,5 mV 10 Hz do 20 kHz od 100 mV do 1 V CMC 0,05 % +0,3 mV 20 kHz do 50 kHz od 100 mV do 1 V CMC 0,11 % +0,5 mV 50 kHz do 100 kHz od 100 mV do 1 V CMC 0,6 % +0,8 mV 100 kHz do 300 kHz od 100 mV do 1 V CMC 4 % +5 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,05 % +3 mV 20 kHz do 50 kHz od 1 V do 10 V CMC 0,11 % +5 mV 50 kHz do 100 kHz od 1 V do 10 V CMC 0,6 % +8 mV 100 kHz do 300 kHz od 1 V do 10 V CMC 4 % +50 mV 10 Hz do 20 kHz od 10 V do 100 V CMC 0,05 % +30 mV 20 kHz do 50 kHz od 10 V do 100 V CMC 0,11 % +50 mV 50 kHz do 100 kHz od 10 V do 100 V CMC 0,6 % +80 mV 100 kHz do 300 kHz od 10 V do 100 V CMC 4 % +0,5 V 10 Hz do 20 kHz od 100 V do 1 kV CMC 0,05 % +0,3 V 20 kHz do 50 kHz od 100 V do 1 kV CMC 0,11 % +0,5 V 50 kHz do 100 kHz (maks. 8.10⁷ VHz) od 100 V do 1 kV CMC 0,6 % +0,8 V 100 kHz do 300 kHz (maks. 8.10⁷ VHz) od 100 V do 1 kV CMC 4 % +5 V Střídavé napětí / zdroje střídavého napětí Kalibrace – elektrické veličiny Přímé měření multimetrem 10 Hz až 20 kHz 1 mV až 100 mV CMC 0,05 % +40 µV 20 kHz až 50 kHz 1 mV až 100 mV CMC 0,11 % +50 µV 50 kHz až 100 kHz 1 mV až 100 mV CMC 0,6 % +80 µV 100 kHz až 300 kHz 1 mV až 100 mV CMC 4 % +0,5 mV 10 Hz až 20 kHz 100 mV až 1 V CMC 0,05 % +0,3 mV 20 kHz až 50 kHz 100 mV až 1 V CMC 0,11 % +0,5 mV 50 kHz až 100 kHz 100 mV až 1 V CMC 0,6 % +0,8 mV 100 kHz až 300 kHz 100 mV až 1 V CMC 4 % +5 mV 10 Hz až 20 kHz 1 V až 10 V CMC 0,05 % +3 mV 20 kHz až 50 kHz 1 V až 10 V CMC 0,11 % +5 mV 50 kHz až 100 kHz 1 V až 10 V CMC 0,6 % +8 mV 100 kHz až 300 kHz 1 V až 10 V CMC 4 % +50 mV 10 Hz až 20 kHz 10 V až 100 V CMC 0,05 % +30 mV 20 kHz až 50 kHz 10 V až 100 V CMC 0,11 % +50 mV 50 kHz až 100 kHz 10 V až 100 V CMC 0,6 % +80 mV 100 kHz až 300 kHz 10 V až 100 V CMC 4 % +0,5 V 10 Hz až 20 kHz 100 V až 1 kV CMC 0,05 % +0,3 V 20 kHz až 50 kHz 100 V až 1 kV CMC 0,11 % +0,5 V 50 kHz až 100 kHz (max. 8.10⁷ VHz) 100 V až 1 kV CMC 0,6 % +0,8 V 100 kHz až 300 kHz (max. 8.10⁷ VHz) 100 V až 1 kV CMC 4 % +5 V VKP01/05 VKP02/05 Napiecie przemienne / zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 10 Hz do 20 kHz od 1 mV do 100 mV CMC 0,05 % +40 µV 20 kHz do 50 kHz od 1 mV do 100 mV CMC 0,11 % +50 µV 50 kHz do 100 kHz od 1 mV do 100 mV CMC 0,6 % +80 µV 100 kHz do 300 kHz od 1 mV do 100 mV CMC 4 % +0,5 mV 10 Hz do 20 kHz od 100 mV do 1 V CMC 0,05 % +0,3 mV 20 kHz do 50 kHz od 100 mV do 1 V CMC 0,11 % +0,5 mV 50 kHz do 100 kHz od 100 mV do 1 V CMC 0,6 % +0,8 mV 100 kHz do 300 kHz od 100 mV do 1 V CMC 4 % +5 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,05 % +3 mV 20 kHz do 50 kHz od 1 V do 10 V CMC 0,11 % +5 mV 50 kHz do 100 kHz od 1 V do 10 V CMC 0,6 % +8 mV 100 kHz do 300 kHz od 1 V do 10 V CMC 4 % +50 mV 10 Hz do 20 kHz od 10 V do 100 V CMC 0,05 % +30 mV 20 kHz do 50 kHz od 10 V do 100 V CMC 0,11 % +50 mV 50 kHz do 100 kHz od 10 V do 100 V CMC 0,6 % +80 mV 100 kHz do 300 kHz od 10 V do 100 V CMC 4 % +0,5 V 10 Hz do 20 kHz od 100 V do 1 kV CMC 0,05 % +0,3 V 20 kHz do 50 kHz od 100 V do 1 kV CMC 0,11 % +0,5 V 50 kHz do 100 kHz (maks. 8.10⁷ VHz) od 100 V do 1 kV CMC 0,6 % +0,8 V 100 kHz do 300 kHz (maks. 8.10⁷ VHz) od 100 V do 1 kV CMC 4 % +5 V Stridave napeti / zdroje stridaveho napeti Kalibrace – elektricke veliciny Prime mereni multimetrem 10 Hz az 20 kHz 1 mV az 100 mV CMC 0,05 % +40 µV 20 kHz az 50 kHz 1 mV az 100 mV CMC 0,11 % +50 µV 50 kHz az 100 kHz 1 mV az 100 mV CMC 0,6 % +80 µV 100 kHz az 300 kHz 1 mV az 100 mV CMC 4 % +0,5 mV 10 Hz az 20 kHz 100 mV az 1 V CMC 0,05 % +0,3 mV 20 kHz az 50 kHz 100 mV az 1 V CMC 0,11 % +0,5 mV 50 kHz az 100 kHz 100 mV az 1 V CMC 0,6 % +0,8 mV 100 kHz az 300 kHz 100 mV az 1 V CMC 4 % +5 mV 10 Hz az 20 kHz 1 V az 10 V CMC 0,05 % +3 mV 20 kHz az 50 kHz 1 V az 10 V CMC 0,11 % +5 mV 50 kHz az 100 kHz 1 V az 10 V CMC 0,6 % +8 mV 100 kHz az 300 kHz 1 V az 10 V CMC 4 % +50 mV 10 Hz az 20 kHz 10 V az 100 V CMC 0,05 % +30 mV 20 kHz az 50 kHz 10 V az 100 V CMC 0,11 % +50 mV 50 kHz az 100 kHz 10 V az 100 V CMC 0,6 % +80 mV 100 kHz az 300 kHz 10 V az 100 V CMC 4 % +0,5 V 10 Hz az 20 kHz 100 V az 1 kV CMC 0,05 % +0,3 V 20 kHz az 50 kHz 100 V az 1 kV CMC 0,11 % +0,5 V 50 kHz az 100 kHz (max. 8.10⁷ VHz) 100 V az 1 kV CMC 0,6 % +0,8 V 100 kHz az 300 kHz (max. 8.10⁷ VHz) 100 V az 1 kV CMC 4 % +5 V VKP01/05 VKP02/05","search_en":"AC voltage / AC voltage sources Calibration – electrical quantities Direct measurement by a multimeter 10 Hz to 20 kHz 1 mV to 100 mV CMC 0,05 % +40 µV 20 kHz to 50 kHz 1 mV to 100 mV CMC 0,11 % +50 µV 50 kHz to 100 kHz 1 mV to 100 mV CMC 0,6 % +80 µV 100 kHz to 300 kHz 1 mV to 100 mV CMC 4 % +0,5 mV 10 Hz to 20 kHz 100 mV to 1 V CMC 0,05 % +0,3 mV 20 kHz to 50 kHz 100 mV to 1 V CMC 0,11 % +0,5 mV 50 kHz to 100 kHz 100 mV to 1 V CMC 0,6 % +0,8 mV 100 kHz to 300 kHz 100 mV to 1 V CMC 4 % +5 mV 10 Hz to 20 kHz 1 V to 10 V CMC 0,05 % +3 mV 20 kHz to 50 kHz 1 V to 10 V CMC 0,11 % +5 mV 50 kHz to 100 kHz 1 V to 10 V CMC 0,6 % +8 mV 100 kHz to 300 kHz 1 V to 10 V CMC 4 % +50 mV 10 Hz to 20 kHz 10 V to 100 V CMC 0,05 % +30 mV 20 kHz to 50 kHz 10 V to 100 V CMC 0,11 % +50 mV 50 kHz to 100 kHz 10 V to 100 V CMC 0,6 % +80 mV 100 kHz to 300 kHz 10 V to 100 V CMC 4 % +0,5 V 10 Hz to 20 kHz 100 V to 1 kV CMC 0,05 % +0,3 V 20 kHz to 50 kHz 100 V to 1 kV CMC 0,11 % +0,5 V 50 kHz to 100 kHz (max. 8.10⁷ VHz) 100 V to 1 kV CMC 0,6 % +0,8 V 100 kHz to 300 kHz (max. 8.10⁷ VHz) 100 V to 1 kV CMC 4 % +5 V VKP01/05 VKP02/05","search_zh":"交流电压 / 交流电压源 校准 – 电学量 用万用表直接测量 10 Hz 至 20 kHz 1 mV 至 100 mV CMC 0,05 % +40 µV 20 kHz 至 50 kHz 1 mV 至 100 mV CMC 0,11 % +50 µV 50 kHz 至 100 kHz 1 mV 至 100 mV CMC 0,6 % +80 µV 100 kHz 至 300 kHz 1 mV 至 100 mV CMC 4 % +0,5 mV 10 Hz 至 20 kHz 100 mV 至 1 V CMC 0,05 % +0,3 mV 20 kHz 至 50 kHz 100 mV 至 1 V CMC 0,11 % +0,5 mV 50 kHz 至 100 kHz 100 mV 至 1 V CMC 0,6 % +0,8 mV 100 kHz 至 300 kHz 100 mV 至 1 V CMC 4 % +5 mV 10 Hz 至 20 kHz 1 V 至 10 V CMC 0,05 % +3 mV 20 kHz 至 50 kHz 1 V 至 10 V CMC 0,11 % +5 mV 50 kHz 至 100 kHz 1 V 至 10 V CMC 0,6 % +8 mV 100 kHz 至 300 kHz 1 V 至 10 V CMC 4 % +50 mV 10 Hz 至 20 kHz 10 V 至 100 V CMC 0,05 % +30 mV 20 kHz 至 50 kHz 10 V 至 100 V CMC 0,11 % +50 mV 50 kHz 至 100 kHz 10 V 至 100 V CMC 0,6 % +80 mV 100 kHz 至 300 kHz 10 V 至 100 V CMC 4 % +0,5 V 10 Hz 至 20 kHz 100 V 至 1 kV CMC 0,05 % +0,3 V 20 kHz 至 50 kHz 100 V 至 1 kV CMC 0,11 % +0,5 V 50 kHz 至 100 kHz（最大 8.10⁷ VHz） 100 V 至 1 kV CMC 0,6 % +0,8 V 100 kHz 至 300 kHz（最大 8.10⁷ VHz） 100 V 至 1 kV CMC 4 % +5 V VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"89b01f4b666206bcf99f71ad","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / źródła napięcia przemiennego","test_object_en":"AC voltage / AC voltage sources","test_object_zh":"交流电压 / 交流电压源","test_object_cs":"Střídavé napětí / zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz do 60 Hz","range":"od 1 kV do 10 kV","cmc":"0,5 % +5 V"}],"parameters_en":[{"name":"50 Hz to 60 Hz","range":"1 kV to 10 kV","cmc":"0,5 % +5 V"}],"parameters_zh":[{"name":"50 Hz 至 60 Hz","range":"1 kV 至 10 kV","cmc":"0,5 % +5 V"}],"parameters_cs":[{"name":"50 Hz až 60 Hz","range":"1 kV až 10 kV","cmc":"0,5 % +5 V"}],"technique":"Pomiar kalibratorem mierników do badań instalacji z dzielnikiem wysokonapięciowym","technique_en":"Measurement by an installation tester calibrator with a high-voltage divider","technique_zh":"用带高压分压器的电气安装测试仪校准器测量","technique_cs":"Měření kalibrátorem revizních přístrojů s vysokonapěťovým děličem","techniques":["Pomiar kalibratorem mierników do badań instalacji z dzielnikiem wysokonapięciowym"],"techniques_en":["Measurement by an installation tester calibrator with a high-voltage divider"],"techniques_zh":["用带高压分压器的电气安装测试仪校准器测量"],"techniques_cs":["Měření kalibrátorem revizních přístrojů s vysokonapěťovým děličem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz do 60 Hz od 1 kV do 10 kV CMC 0,5 % +5 V\nPomiar kalibratorem mierników do badań instalacji z dzielnikiem wysokonapięciowym","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar kalibratorem mierników do badań instalacji z dzielnikiem wysokonapięciowym 50 Hz do 60 Hz od 1 kV do 10 kV CMC 0,5 % +5 V Střídavé napětí / zdroje střídavého napětí Kalibrace – elektrické veličiny Měření kalibrátorem revizních přístrojů s vysokonapěťovým děličem 50 Hz až 60 Hz 1 kV až 10 kV CMC 0,5 % +5 V VKP01/05 VKP02/05 Napiecie przemienne / zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar kalibratorem miernikow do badan instalacji z dzielnikiem wysokonapieciowym 50 Hz do 60 Hz od 1 kV do 10 kV CMC 0,5 % +5 V Stridave napeti / zdroje stridaveho napeti Kalibrace – elektricke veliciny Mereni kalibratorem reviznich pristroju s vysokonapetovym delicem 50 Hz az 60 Hz 1 kV az 10 kV CMC 0,5 % +5 V VKP01/05 VKP02/05","search_en":"AC voltage / AC voltage sources Calibration – electrical quantities Measurement by an installation tester calibrator with a high-voltage divider 50 Hz to 60 Hz 1 kV to 10 kV CMC 0,5 % +5 V VKP01/05 VKP02/05","search_zh":"交流电压 / 交流电压源 校准 – 电学量 用带高压分压器的电气安装测试仪校准器测量 50 Hz 至 60 Hz 1 kV 至 10 kV CMC 0,5 % +5 V VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"70c45e8b0f37d9dffbd03c5d","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / mierniki prądu stałego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi","test_object_en":"DC current / DC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers","test_object_zh":"直流电流 / 直流电流表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪","test_object_cs":"Stejnosměrný proud / měřidla stejnosměrného proudu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 120 µA","cmc":"97 µA/A +6 nA"},{"name":"","range":"od 120 µA do 1,2 mA","cmc":"78 µA/A +15 nA"},{"name":"","range":"od 1,2 mA do 12 mA","cmc":"78 µA/A +80 nA"},{"name":"","range":"od 12 mA do 120 mA","cmc":"78 µA/A +800 nA"},{"name":"","range":"od 120 mA do 1,2 A","cmc":"120 µA/A +10 µA"},{"name":"","range":"od 1,2 A do 3,1 A","cmc":"230 µA/A +150 µA"},{"name":"","range":"od 3,1 A do 12 A","cmc":"230 µA/A +250 µA"},{"name":"","range":"od 12 A do 30,2 A","cmc":"780 µA/A +500 µA"}],"parameters_en":[{"name":"","range":"0 µA to 120 µA","cmc":"97 µA/A +6 nA"},{"name":"","range":"120 µA to 1,2 mA","cmc":"78 µA/A +15 nA"},{"name":"","range":"1,2 mA to 12 mA","cmc":"78 µA/A +80 nA"},{"name":"","range":"12 mA to 120 mA","cmc":"78 µA/A +800 nA"},{"name":"","range":"120 mA to 1,2 A","cmc":"120 µA/A +10 µA"},{"name":"","range":"1,2 A to 3,1 A","cmc":"230 µA/A +150 µA"},{"name":"","range":"3,1 A to 12 A","cmc":"230 µA/A +250 µA"},{"name":"","range":"12 A to 30,2 A","cmc":"780 µA/A +500 µA"}],"parameters_zh":[{"name":"","range":"0 µA 至 120 µA","cmc":"97 µA/A +6 nA"},{"name":"","range":"120 µA 至 1,2 mA","cmc":"78 µA/A +15 nA"},{"name":"","range":"1,2 mA 至 12 mA","cmc":"78 µA/A +80 nA"},{"name":"","range":"12 mA 至 120 mA","cmc":"78 µA/A +800 nA"},{"name":"","range":"120 mA 至 1,2 A","cmc":"120 µA/A +10 µA"},{"name":"","range":"1,2 A 至 3,1 A","cmc":"230 µA/A +150 µA"},{"name":"","range":"3,1 A 至 12 A","cmc":"230 µA/A +250 µA"},{"name":"","range":"12 A 至 30,2 A","cmc":"780 µA/A +500 µA"}],"parameters_cs":[{"name":"","range":"0 µA až 120 µA","cmc":"97 µA/A +6 nA"},{"name":"","range":"120 µA až 1,2 mA","cmc":"78 µA/A +15 nA"},{"name":"","range":"1,2 mA až 12 mA","cmc":"78 µA/A +80 nA"},{"name":"","range":"12 mA až 120 mA","cmc":"78 µA/A +800 nA"},{"name":"","range":"120 mA až 1,2 A","cmc":"120 µA/A +10 µA"},{"name":"","range":"1,2 A až 3,1 A","cmc":"230 µA/A +150 µA"},{"name":"","range":"3,1 A až 12 A","cmc":"230 µA/A +250 µA"},{"name":"","range":"12 A až 30,2 A","cmc":"780 µA/A +500 µA"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation by a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation by a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 120 µA CMC 97 µA/A +6 nA\nod 120 µA do 1,2 mA CMC 78 µA/A +15 nA\nod 1,2 mA do 12 mA CMC 78 µA/A +80 nA\nod 12 mA do 120 mA CMC 78 µA/A +800 nA\nod 120 mA do 1,2 A CMC 120 µA/A +10 µA\nod 1,2 A do 3,1 A CMC 230 µA/A +150 µA\nod 3,1 A do 12 A CMC 230 µA/A +250 µA\nod 12 A do 30,2 A CMC 780 µA/A +500 µA\nBezpośrednie generowanie kalibratorem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki prądu stałego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0 µA do 120 µA CMC 97 µA/A +6 nA od 120 µA do 1,2 mA CMC 78 µA/A +15 nA od 1,2 mA do 12 mA CMC 78 µA/A +80 nA od 12 mA do 120 mA CMC 78 µA/A +800 nA od 120 mA do 1,2 A CMC 120 µA/A +10 µA od 1,2 A do 3,1 A CMC 230 µA/A +150 µA od 3,1 A do 12 A CMC 230 µA/A +250 µA od 12 A do 30,2 A CMC 780 µA/A +500 µA Stejnosměrný proud / měřidla stejnosměrného proudu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0 µA až 120 µA CMC 97 µA/A +6 nA 120 µA až 1,2 mA CMC 78 µA/A +15 nA 1,2 mA až 12 mA CMC 78 µA/A +80 nA 12 mA až 120 mA CMC 78 µA/A +800 nA 120 mA až 1,2 A CMC 120 µA/A +10 µA 1,2 A až 3,1 A CMC 230 µA/A +150 µA 3,1 A až 12 A CMC 230 µA/A +250 µA 12 A až 30,2 A CMC 780 µA/A +500 µA VKP01/05 VKP02/05 Prad staly / mierniki pradu stalego, kalibratory, multimetry, mierniki cegowe, mierniki do badan instalacji, testery wielofunkcyjne, mierniki rezystancji uziemien, mierniki uziemien, testery elektronarzedzi Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0 µA do 120 µA CMC 97 µA/A +6 nA od 120 µA do 1,2 mA CMC 78 µA/A +15 nA od 1,2 mA do 12 mA CMC 78 µA/A +80 nA od 12 mA do 120 mA CMC 78 µA/A +800 nA od 120 mA do 1,2 A CMC 120 µA/A +10 µA od 1,2 A do 3,1 A CMC 230 µA/A +150 µA od 3,1 A do 12 A CMC 230 µA/A +250 µA od 12 A do 30,2 A CMC 780 µA/A +500 µA Stejnosmerny proud / meridla stejnosmerneho proudu, kalibratory, multimetry, klestova meridla, revizni meridla, multifunkcni testery, merice zemniho odporu, meridla uzemneni, testery rucniho naradi Kalibrace – elektricke veliciny Prime generovani kalibratorem 0 µA az 120 µA CMC 97 µA/A +6 nA 120 µA az 1,2 mA CMC 78 µA/A +15 nA 1,2 mA az 12 mA CMC 78 µA/A +80 nA 12 mA az 120 mA CMC 78 µA/A +800 nA 120 mA az 1,2 A CMC 120 µA/A +10 µA 1,2 A az 3,1 A CMC 230 µA/A +150 µA 3,1 A az 12 A CMC 230 µA/A +250 µA 12 A az 30,2 A CMC 780 µA/A +500 µA VKP01/05 VKP02/05","search_en":"DC current / DC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers Calibration – electrical quantities Direct generation by a calibrator 0 µA to 120 µA CMC 97 µA/A +6 nA 120 µA to 1,2 mA CMC 78 µA/A +15 nA 1,2 mA to 12 mA CMC 78 µA/A +80 nA 12 mA to 120 mA CMC 78 µA/A +800 nA 120 mA to 1,2 A CMC 120 µA/A +10 µA 1,2 A to 3,1 A CMC 230 µA/A +150 µA 3,1 A to 12 A CMC 230 µA/A +250 µA 12 A to 30,2 A CMC 780 µA/A +500 µA VKP01/05 VKP02/05","search_zh":"直流电流 / 直流电流表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪 校准 – 电学量 用校准器直接产生 0 µA 至 120 µA CMC 97 µA/A +6 nA 120 µA 至 1,2 mA CMC 78 µA/A +15 nA 1,2 mA 至 12 mA CMC 78 µA/A +80 nA 12 mA 至 120 mA CMC 78 µA/A +800 nA 120 mA 至 1,2 A CMC 120 µA/A +10 µA 1,2 A 至 3,1 A CMC 230 µA/A +150 µA 3,1 A 至 12 A CMC 230 µA/A +250 µA 12 A 至 30,2 A CMC 780 µA/A +500 µA VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bf05435a8658b8c5892cb102","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / mierniki prądu stałego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi","test_object_en":"DC current / DC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers","test_object_zh":"直流电流 / 直流电流表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪","test_object_cs":"Stejnosměrný proud / měřidla stejnosměrného proudu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 A do 16,5 A","cmc":"0,5 % +20 mA"},{"name":"","range":"od 16,5 A do 150 A","cmc":"0,5 % +0,14 A"},{"name":"","range":"od 150 A do 1000 A","cmc":"0,5 % +0,5 A"}],"parameters_en":[{"name":"","range":"10 A to 16,5 A","cmc":"0,5 % +20 mA"},{"name":"","range":"16,5 A to 150 A","cmc":"0,5 % +0,14 A"},{"name":"","range":"150 A to 1000 A","cmc":"0,5 % +0,5 A"}],"parameters_zh":[{"name":"","range":"10 A 至 16,5 A","cmc":"0,5 % +20 mA"},{"name":"","range":"16,5 A 至 150 A","cmc":"0,5 % +0,14 A"},{"name":"","range":"150 A 至 1000 A","cmc":"0,5 % +0,5 A"}],"parameters_cs":[{"name":"","range":"10 A až 16,5 A","cmc":"0,5 % +20 mA"},{"name":"","range":"16,5 A až 150 A","cmc":"0,5 % +0,14 A"},{"name":"","range":"150 A až 1000 A","cmc":"0,5 % +0,5 A"}],"technique":"Pośrednie generowanie kalibratorem z symulacją prądu cewkami prądowymi","technique_en":"Indirect generation by a calibrator with current simulation by current coils","technique_zh":"用校准器以电流线圈模拟电流间接产生","technique_cs":"Nepřímé generování kalibrátorem se simulací proudu proudovými cívkami","techniques":["Pośrednie generowanie kalibratorem z symulacją prądu cewkami prądowymi"],"techniques_en":["Indirect generation by a calibrator with current simulation by current coils"],"techniques_zh":["用校准器以电流线圈模拟电流间接产生"],"techniques_cs":["Nepřímé generování kalibrátorem se simulací proudu proudovými cívkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 10 A do 16,5 A CMC 0,5 % +20 mA\nod 16,5 A do 150 A CMC 0,5 % +0,14 A\nod 150 A do 1000 A CMC 0,5 % +0,5 A\nPośrednie generowanie kalibratorem z symulacją prądu cewkami prądowymi","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki prądu stałego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi Wzorcowanie – wielkości elektryczne Pośrednie generowanie kalibratorem z symulacją prądu cewkami prądowymi od 10 A do 16,5 A CMC 0,5 % +20 mA od 16,5 A do 150 A CMC 0,5 % +0,14 A od 150 A do 1000 A CMC 0,5 % +0,5 A Stejnosměrný proud / měřidla stejnosměrného proudu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí Kalibrace – elektrické veličiny Nepřímé generování kalibrátorem se simulací proudu proudovými cívkami 10 A až 16,5 A CMC 0,5 % +20 mA 16,5 A až 150 A CMC 0,5 % +0,14 A 150 A až 1000 A CMC 0,5 % +0,5 A VKP01/05 VKP02/05 Prad staly / mierniki pradu stalego, kalibratory, multimetry, mierniki cegowe, mierniki do badan instalacji, testery wielofunkcyjne, mierniki rezystancji uziemien, mierniki uziemien, testery elektronarzedzi Wzorcowanie – wielkosci elektryczne Posrednie generowanie kalibratorem z symulacja pradu cewkami pradowymi od 10 A do 16,5 A CMC 0,5 % +20 mA od 16,5 A do 150 A CMC 0,5 % +0,14 A od 150 A do 1000 A CMC 0,5 % +0,5 A Stejnosmerny proud / meridla stejnosmerneho proudu, kalibratory, multimetry, klestova meridla, revizni meridla, multifunkcni testery, merice zemniho odporu, meridla uzemneni, testery rucniho naradi Kalibrace – elektricke veliciny Neprime generovani kalibratorem se simulaci proudu proudovymi civkami 10 A az 16,5 A CMC 0,5 % +20 mA 16,5 A az 150 A CMC 0,5 % +0,14 A 150 A az 1000 A CMC 0,5 % +0,5 A VKP01/05 VKP02/05","search_en":"DC current / DC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers Calibration – electrical quantities Indirect generation by a calibrator with current simulation by current coils 10 A to 16,5 A CMC 0,5 % +20 mA 16,5 A to 150 A CMC 0,5 % +0,14 A 150 A to 1000 A CMC 0,5 % +0,5 A VKP01/05 VKP02/05","search_zh":"直流电流 / 直流电流表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪 校准 – 电学量 用校准器以电流线圈模拟电流间接产生 10 A 至 16,5 A CMC 0,5 % +20 mA 16,5 A 至 150 A CMC 0,5 % +0,14 A 150 A 至 1000 A CMC 0,5 % +0,5 A VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"84da26e251052d66876e7ce9","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła prądu stałego","test_object_en":"DC current / DC current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 100 µA","cmc":"0,04 % +0,025 µA"},{"name":"","range":"od 100 µA do 1 mA","cmc":"0,03 % +0,05 µA"},{"name":"","range":"od 1 mA do 10 mA","cmc":"0,03 % +2 µA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,03 % +5 µA"},{"name":"","range":"od 100 mA do 400 mA","cmc":"0,04 % +5 µA"},{"name":"","range":"od 400 mA do 1 A","cmc":"0,04 % +20 µA"},{"name":"","range":"od 1 A do 3 A","cmc":"0,08 % +0,6 mA"},{"name":"","range":"od 3 A do 10 A","cmc":"0,12 % +0,8 mA"}],"parameters_en":[{"name":"","range":"0 µA to 100 µA","cmc":"0,04 % +0,025 µA"},{"name":"","range":"100 µA to 1 mA","cmc":"0,03 % +0,05 µA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,03 % +2 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,03 % +5 µA"},{"name":"","range":"100 mA to 400 mA","cmc":"0,04 % +5 µA"},{"name":"","range":"400 mA to 1 A","cmc":"0,04 % +20 µA"},{"name":"","range":"1 A to 3 A","cmc":"0,08 % +0,6 mA"},{"name":"","range":"3 A to 10 A","cmc":"0,12 % +0,8 mA"}],"parameters_zh":[{"name":"","range":"0 µA 至 100 µA","cmc":"0,04 % +0,025 µA"},{"name":"","range":"100 µA 至 1 mA","cmc":"0,03 % +0,05 µA"},{"name":"","range":"1 mA 至 10 mA","cmc":"0,03 % +2 µA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,03 % +5 µA"},{"name":"","range":"100 mA 至 400 mA","cmc":"0,04 % +5 µA"},{"name":"","range":"400 mA 至 1 A","cmc":"0,04 % +20 µA"},{"name":"","range":"1 A 至 3 A","cmc":"0,08 % +0,6 mA"},{"name":"","range":"3 A 至 10 A","cmc":"0,12 % +0,8 mA"}],"parameters_cs":[{"name":"","range":"0 µA až 100 µA","cmc":"0,04 % +0,025 µA"},{"name":"","range":"100 µA až 1 mA","cmc":"0,03 % +0,05 µA"},{"name":"","range":"1 mA až 10 mA","cmc":"0,03 % +2 µA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,03 % +5 µA"},{"name":"","range":"100 mA až 400 mA","cmc":"0,04 % +5 µA"},{"name":"","range":"400 mA až 1 A","cmc":"0,04 % +20 µA"},{"name":"","range":"1 A až 3 A","cmc":"0,08 % +0,6 mA"},{"name":"","range":"3 A až 10 A","cmc":"0,12 % +0,8 mA"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement by a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement by a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 100 µA CMC 0,04 % +0,025 µA\nod 100 µA do 1 mA CMC 0,03 % +0,05 µA\nod 1 mA do 10 mA CMC 0,03 % +2 µA\nod 10 mA do 100 mA CMC 0,03 % +5 µA\nod 100 mA do 400 mA CMC 0,04 % +5 µA\nod 400 mA do 1 A CMC 0,04 % +20 µA\nod 1 A do 3 A CMC 0,08 % +0,6 mA\nod 3 A do 10 A CMC 0,12 % +0,8 mA\nPomiar bezpośredni multimetrem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 µA do 100 µA CMC 0,04 % +0,025 µA od 100 µA do 1 mA CMC 0,03 % +0,05 µA od 1 mA do 10 mA CMC 0,03 % +2 µA od 10 mA do 100 mA CMC 0,03 % +5 µA od 100 mA do 400 mA CMC 0,04 % +5 µA od 400 mA do 1 A CMC 0,04 % +20 µA od 1 A do 3 A CMC 0,08 % +0,6 mA od 3 A do 10 A CMC 0,12 % +0,8 mA Stejnosměrný proud / zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření multimetrem 0 µA až 100 µA CMC 0,04 % +0,025 µA 100 µA až 1 mA CMC 0,03 % +0,05 µA 1 mA až 10 mA CMC 0,03 % +2 µA 10 mA až 100 mA CMC 0,03 % +5 µA 100 mA až 400 mA CMC 0,04 % +5 µA 400 mA až 1 A CMC 0,04 % +20 µA 1 A až 3 A CMC 0,08 % +0,6 mA 3 A až 10 A CMC 0,12 % +0,8 mA VKP01/05 VKP02/05 Prad staly / zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 µA do 100 µA CMC 0,04 % +0,025 µA od 100 µA do 1 mA CMC 0,03 % +0,05 µA od 1 mA do 10 mA CMC 0,03 % +2 µA od 10 mA do 100 mA CMC 0,03 % +5 µA od 100 mA do 400 mA CMC 0,04 % +5 µA od 400 mA do 1 A CMC 0,04 % +20 µA od 1 A do 3 A CMC 0,08 % +0,6 mA od 3 A do 10 A CMC 0,12 % +0,8 mA Stejnosmerny proud / zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni multimetrem 0 µA az 100 µA CMC 0,04 % +0,025 µA 100 µA az 1 mA CMC 0,03 % +0,05 µA 1 mA az 10 mA CMC 0,03 % +2 µA 10 mA az 100 mA CMC 0,03 % +5 µA 100 mA az 400 mA CMC 0,04 % +5 µA 400 mA az 1 A CMC 0,04 % +20 µA 1 A az 3 A CMC 0,08 % +0,6 mA 3 A az 10 A CMC 0,12 % +0,8 mA VKP01/05 VKP02/05","search_en":"DC current / DC current sources Calibration – electrical quantities Direct measurement by a multimeter 0 µA to 100 µA CMC 0,04 % +0,025 µA 100 µA to 1 mA CMC 0,03 % +0,05 µA 1 mA to 10 mA CMC 0,03 % +2 µA 10 mA to 100 mA CMC 0,03 % +5 µA 100 mA to 400 mA CMC 0,04 % +5 µA 400 mA to 1 A CMC 0,04 % +20 µA 1 A to 3 A CMC 0,08 % +0,6 mA 3 A to 10 A CMC 0,12 % +0,8 mA VKP01/05 VKP02/05","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用万用表直接测量 0 µA 至 100 µA CMC 0,04 % +0,025 µA 100 µA 至 1 mA CMC 0,03 % +0,05 µA 1 mA 至 10 mA CMC 0,03 % +2 µA 10 mA 至 100 mA CMC 0,03 % +5 µA 100 mA 至 400 mA CMC 0,04 % +5 µA 400 mA 至 1 A CMC 0,04 % +20 µA 1 A 至 3 A CMC 0,08 % +0,6 mA 3 A 至 10 A CMC 0,12 % +0,8 mA VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"319f51417e9b6625f2e1ea5d","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła prądu stałego","test_object_en":"DC current / DC current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 A do 30 A","cmc":"0,3 % +15 mA"}],"parameters_en":[{"name":"","range":"10 A to 30 A","cmc":"0,3 % +15 mA"}],"parameters_zh":[{"name":"","range":"10 A 至 30 A","cmc":"0,3 % +15 mA"}],"parameters_cs":[{"name":"","range":"10 A až 30 A","cmc":"0,3 % +15 mA"}],"technique":"Pomiar bezpośredni kalibratorem mierników do badań instalacji","technique_en":"Direct measurement by an installation tester calibrator","technique_zh":"用电气安装测试仪校准器直接测量","technique_cs":"Přímé měření kalibrátorem revizních přístrojů","techniques":["Pomiar bezpośredni kalibratorem mierników do badań instalacji"],"techniques_en":["Direct measurement by an installation tester calibrator"],"techniques_zh":["用电气安装测试仪校准器直接测量"],"techniques_cs":["Přímé měření kalibrátorem revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 10 A do 30 A CMC 0,3 % +15 mA\nPomiar bezpośredni kalibratorem mierników do badań instalacji","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratorem mierników do badań instalacji od 10 A do 30 A CMC 0,3 % +15 mA Stejnosměrný proud / zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření kalibrátorem revizních přístrojů 10 A až 30 A CMC 0,3 % +15 mA VKP01/05 VKP02/05 Prad staly / zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratorem miernikow do badan instalacji od 10 A do 30 A CMC 0,3 % +15 mA Stejnosmerny proud / zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni kalibratorem reviznich pristroju 10 A az 30 A CMC 0,3 % +15 mA VKP01/05 VKP02/05","search_en":"DC current / DC current sources Calibration – electrical quantities Direct measurement by an installation tester calibrator 10 A to 30 A CMC 0,3 % +15 mA VKP01/05 VKP02/05","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用电气安装测试仪校准器直接测量 10 A 至 30 A CMC 0,3 % +15 mA VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cfb077d0e10c5621629177cb","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / mierniki prądu przemiennego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi","test_object_en":"AC current / AC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers","test_object_zh":"交流电流 / 交流电流表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪","test_object_cs":"Střídavý proud / měřidla střídavého proudu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"3 Hz do 5 kHz","range":"od 0,010 mA do 0,12 mA","cmc":"190 µA/A +10 nA"},{"name":"5 kHz do 10 kHz","range":"od 0,010 mA do 0,12 mA","cmc":"1 200 µA/A +40 nA"},{"name":"10 kHz do 30 kHz","range":"od 0,010 mA do 0,12 mA","cmc":"3 900 µA/A +1 µA"},{"name":"3 Hz do 5 kHz","range":"od 0,12 mA do 1,2 mA","cmc":"190 µA/A +100 nA"},{"name":"5 kHz do 10 kHz","range":"od 0,12 mA do 1,2 mA","cmc":"1 200 µA/A +100 nA"},{"name":"10 kHz do 30 kHz","range":"od 0,12 mA do 1,2 mA","cmc":"3 900 µA/A +5 µA"},{"name":"3 Hz do 5 kHz","range":"od 1,2 mA do 12 mA","cmc":"190 µA/A +1 µA"},{"name":"5 kHz do 10 kHz","range":"od 1,2 mA do 12 mA","cmc":"1 200 µA/A +1 µA"},{"name":"10 kHz do 30 kHz","range":"od 1,2 mA do 12 mA","cmc":"3 900 µA/A +10 µA"},{"name":"3 Hz do 45 Hz","range":"od 12 mA do 120 mA","cmc":"190 µA/A +10 µA"},{"name":"45 Hz do 1 kHz","range":"od 12 mA do 120 mA","cmc":"120 µA/A +5 µA"},{"name":"1 kHz do 5 kHz","range":"od 12 mA do 120 mA","cmc":"190 µA/A +8 µA"},{"name":"5 kHz do 10 kHz","range":"od 12 mA do 120 mA","cmc":"1 200 µA/A +10 µA"},{"name":"10 kHz do 30 kHz","range":"od 12 mA do 120 mA","cmc":"3 900 µA/A +100 µA"},{"name":"3 Hz do 45 Hz","range":"od 120 mA do 1,2 A","cmc":"190 µA/A +100 µA"},{"name":"45 Hz do 1 kHz","range":"od 120 mA do 1,2 A","cmc":"120 µA/A +50 µA"},{"name":"1 kHz do 5 kHz","range":"od 120 mA do 1,2 A","cmc":"190 µA/A +80 µA"},{"name":"5 kHz do 10 kHz","range":"od 120 mA do 1,2 A","cmc":"1 900 µA/A +300 µA"},{"name":"10 kHz do 30 kHz","range":"od 120 mA do 1,2 A","cmc":"3 900 µA/A +300 µA"},{"name":"3 Hz do 45 Hz","range":"od 1,2 A do 3,1 A","cmc":"290 µA/A +500 µA"},{"name":"45 Hz do 1 kHz","range":"od 1,2 A do 3,1 A","cmc":"190 µA/A +300 µA"},{"name":"1 kHz do 5 kHz","range":"od 1,2 A do 3,1 A","cmc":"290 µA/A +300 µA"},{"name":"5 kHz do 10 kHz","range":"od 1,2 A do 3,1 A","cmc":"1 900 µA/A +500 µA"},{"name":"3 Hz do 45 Hz","range":"od 3,1 A do 12 A","cmc":"290 µA/A +1 000 µA"},{"name":"45 Hz do 1 kHz","range":"od 3,1 A do 12 A","cmc":"230 µA/A +500 µA"},{"name":"1 kHz do 5 kHz","range":"od 3,1 A do 12 A","cmc":"290 µA/A +800 µA"},{"name":"5 kHz do 10 kHz","range":"od 3,1 A do 12 A","cmc":"1 900 µA/A +1 000 µA"},{"name":"3 Hz do 45 Hz","range":"od 12 A do 30.2 A","cmc":"780 µA/A +10 mA"},{"name":"45 Hz do 1 kHz","range":"od 12 A do 30.2 A","cmc":"540 µA/A +8 mA"},{"name":"1 kHz do 5 kHz","range":"od 12 A do 30.2 A","cmc":"3 900 µA/A +8 mA"}],"parameters_en":[{"name":"3 Hz to 5 kHz","range":"0,010 mA to 0,12 mA","cmc":"190 µA/A +10 nA"},{"name":"5 kHz to 10 kHz","range":"0,010 mA to 0,12 mA","cmc":"1 200 µA/A +40 nA"},{"name":"10 kHz to 30 kHz","range":"0,010 mA to 0,12 mA","cmc":"3 900 µA/A +1 µA"},{"name":"3 Hz to 5 kHz","range":"0,12 mA to 1,2 mA","cmc":"190 µA/A +100 nA"},{"name":"5 kHz to 10 kHz","range":"0,12 mA to 1,2 mA","cmc":"1 200 µA/A +100 nA"},{"name":"10 kHz to 30 kHz","range":"0,12 mA to 1,2 mA","cmc":"3 900 µA/A +5 µA"},{"name":"3 Hz to 5 kHz","range":"1,2 mA to 12 mA","cmc":"190 µA/A +1 µA"},{"name":"5 kHz to 10 kHz","range":"1,2 mA to 12 mA","cmc":"1 200 µA/A +1 µA"},{"name":"10 kHz to 30 kHz","range":"1,2 mA to 12 mA","cmc":"3 900 µA/A +10 µA"},{"name":"3 Hz to 45 Hz","range":"12 mA to 120 mA","cmc":"190 µA/A +10 µA"},{"name":"45 Hz to 1 kHz","range":"12 mA to 120 mA","cmc":"120 µA/A +5 µA"},{"name":"1 kHz to 5 kHz","range":"12 mA to 120 mA","cmc":"190 µA/A +8 µA"},{"name":"5 kHz to 10 kHz","range":"12 mA to 120 mA","cmc":"1 200 µA/A +10 µA"},{"name":"10 kHz to 30 kHz","range":"12 mA to 120 mA","cmc":"3 900 µA/A +100 µA"},{"name":"3 Hz to 45 Hz","range":"120 mA to 1,2 A","cmc":"190 µA/A +100 µA"},{"name":"45 Hz to 1 kHz","range":"120 mA to 1,2 A","cmc":"120 µA/A +50 µA"},{"name":"1 kHz to 5 kHz","range":"120 mA to 1,2 A","cmc":"190 µA/A +80 µA"},{"name":"5 kHz to 10 kHz","range":"120 mA to 1,2 A","cmc":"1 900 µA/A +300 µA"},{"name":"10 kHz to 30 kHz","range":"120 mA to 1,2 A","cmc":"3 900 µA/A +300 µA"},{"name":"3 Hz to 45 Hz","range":"1,2 A to 3,1 A","cmc":"290 µA/A +500 µA"},{"name":"45 Hz to 1 kHz","range":"1,2 A to 3,1 A","cmc":"190 µA/A +300 µA"},{"name":"1 kHz to 5 kHz","range":"1,2 A to 3,1 A","cmc":"290 µA/A +300 µA"},{"name":"5 kHz to 10 kHz","range":"1,2 A to 3,1 A","cmc":"1 900 µA/A +500 µA"},{"name":"3 Hz to 45 Hz","range":"3,1 A to 12 A","cmc":"290 µA/A +1 000 µA"},{"name":"45 Hz to 1 kHz","range":"3,1 A to 12 A","cmc":"230 µA/A +500 µA"},{"name":"1 kHz to 5 kHz","range":"3,1 A to 12 A","cmc":"290 µA/A +800 µA"},{"name":"5 kHz to 10 kHz","range":"3,1 A to 12 A","cmc":"1 900 µA/A +1 000 µA"},{"name":"3 Hz to 45 Hz","range":"12 A to 30.2 A","cmc":"780 µA/A +10 mA"},{"name":"45 Hz to 1 kHz","range":"12 A to 30.2 A","cmc":"540 µA/A +8 mA"},{"name":"1 kHz to 5 kHz","range":"12 A to 30.2 A","cmc":"3 900 µA/A +8 mA"}],"parameters_zh":[{"name":"3 Hz 至 5 kHz","range":"0,010 mA 至 0,12 mA","cmc":"190 µA/A +10 nA"},{"name":"5 kHz 至 10 kHz","range":"0,010 mA 至 0,12 mA","cmc":"1 200 µA/A +40 nA"},{"name":"10 kHz 至 30 kHz","range":"0,010 mA 至 0,12 mA","cmc":"3 900 µA/A +1 µA"},{"name":"3 Hz 至 5 kHz","range":"0,12 mA 至 1,2 mA","cmc":"190 µA/A +100 nA"},{"name":"5 kHz 至 10 kHz","range":"0,12 mA 至 1,2 mA","cmc":"1 200 µA/A +100 nA"},{"name":"10 kHz 至 30 kHz","range":"0,12 mA 至 1,2 mA","cmc":"3 900 µA/A +5 µA"},{"name":"3 Hz 至 5 kHz","range":"1,2 mA 至 12 mA","cmc":"190 µA/A +1 µA"},{"name":"5 kHz 至 10 kHz","range":"1,2 mA 至 12 mA","cmc":"1 200 µA/A +1 µA"},{"name":"10 kHz 至 30 kHz","range":"1,2 mA 至 12 mA","cmc":"3 900 µA/A +10 µA"},{"name":"3 Hz 至 45 Hz","range":"12 mA 至 120 mA","cmc":"190 µA/A +10 µA"},{"name":"45 Hz 至 1 kHz","range":"12 mA 至 120 mA","cmc":"120 µA/A +5 µA"},{"name":"1 kHz 至 5 kHz","range":"12 mA 至 120 mA","cmc":"190 µA/A +8 µA"},{"name":"5 kHz 至 10 kHz","range":"12 mA 至 120 mA","cmc":"1 200 µA/A +10 µA"},{"name":"10 kHz 至 30 kHz","range":"12 mA 至 120 mA","cmc":"3 900 µA/A +100 µA"},{"name":"3 Hz 至 45 Hz","range":"120 mA 至 1,2 A","cmc":"190 µA/A +100 µA"},{"name":"45 Hz 至 1 kHz","range":"120 mA 至 1,2 A","cmc":"120 µA/A +50 µA"},{"name":"1 kHz 至 5 kHz","range":"120 mA 至 1,2 A","cmc":"190 µA/A +80 µA"},{"name":"5 kHz 至 10 kHz","range":"120 mA 至 1,2 A","cmc":"1 900 µA/A +300 µA"},{"name":"10 kHz 至 30 kHz","range":"120 mA 至 1,2 A","cmc":"3 900 µA/A +300 µA"},{"name":"3 Hz 至 45 Hz","range":"1,2 A 至 3,1 A","cmc":"290 µA/A +500 µA"},{"name":"45 Hz 至 1 kHz","range":"1,2 A 至 3,1 A","cmc":"190 µA/A +300 µA"},{"name":"1 kHz 至 5 kHz","range":"1,2 A 至 3,1 A","cmc":"290 µA/A +300 µA"},{"name":"5 kHz 至 10 kHz","range":"1,2 A 至 3,1 A","cmc":"1 900 µA/A +500 µA"},{"name":"3 Hz 至 45 Hz","range":"3,1 A 至 12 A","cmc":"290 µA/A +1 000 µA"},{"name":"45 Hz 至 1 kHz","range":"3,1 A 至 12 A","cmc":"230 µA/A +500 µA"},{"name":"1 kHz 至 5 kHz","range":"3,1 A 至 12 A","cmc":"290 µA/A +800 µA"},{"name":"5 kHz 至 10 kHz","range":"3,1 A 至 12 A","cmc":"1 900 µA/A +1 000 µA"},{"name":"3 Hz 至 45 Hz","range":"12 A 至 30.2 A","cmc":"780 µA/A +10 mA"},{"name":"45 Hz 至 1 kHz","range":"12 A 至 30.2 A","cmc":"540 µA/A +8 mA"},{"name":"1 kHz 至 5 kHz","range":"12 A 至 30.2 A","cmc":"3 900 µA/A +8 mA"}],"parameters_cs":[{"name":"3 Hz až 5 kHz","range":"0,010 mA až 0,12 mA","cmc":"190 µA/A +10 nA"},{"name":"5 kHz až 10 kHz","range":"0,010 mA až 0,12 mA","cmc":"1 200 µA/A +40 nA"},{"name":"10 kHz až 30 kHz","range":"0,010 mA až 0,12 mA","cmc":"3 900 µA/A +1 µA"},{"name":"3 Hz až 5 kHz","range":"0,12 mA až 1,2 mA","cmc":"190 µA/A +100 nA"},{"name":"5 kHz až 10 kHz","range":"0,12 mA až 1,2 mA","cmc":"1 200 µA/A +100 nA"},{"name":"10 kHz až 30 kHz","range":"0,12 mA až 1,2 mA","cmc":"3 900 µA/A +5 µA"},{"name":"3 Hz až 5 kHz","range":"1,2 mA až 12 mA","cmc":"190 µA/A +1 µA"},{"name":"5 kHz až 10 kHz","range":"1,2 mA až 12 mA","cmc":"1 200 µA/A +1 µA"},{"name":"10 kHz až 30 kHz","range":"1,2 mA až 12 mA","cmc":"3 900 µA/A +10 µA"},{"name":"3 Hz až 45 Hz","range":"12 mA až 120 mA","cmc":"190 µA/A +10 µA"},{"name":"45 Hz až 1 kHz","range":"12 mA až 120 mA","cmc":"120 µA/A +5 µA"},{"name":"1 kHz až 5 kHz","range":"12 mA až 120 mA","cmc":"190 µA/A +8 µA"},{"name":"5 kHz až 10 kHz","range":"12 mA až 120 mA","cmc":"1 200 µA/A +10 µA"},{"name":"10 kHz až 30 kHz","range":"12 mA až 120 mA","cmc":"3 900 µA/A +100 µA"},{"name":"3 Hz až 45 Hz","range":"120 mA až 1,2 A","cmc":"190 µA/A +100 µA"},{"name":"45 Hz až 1 kHz","range":"120 mA až 1,2 A","cmc":"120 µA/A +50 µA"},{"name":"1 kHz až 5 kHz","range":"120 mA až 1,2 A","cmc":"190 µA/A +80 µA"},{"name":"5 kHz až 10 kHz","range":"120 mA až 1,2 A","cmc":"1 900 µA/A +300 µA"},{"name":"10 kHz až 30 kHz","range":"120 mA až 1,2 A","cmc":"3 900 µA/A +300 µA"},{"name":"3 Hz až 45 Hz","range":"1,2 A až 3,1 A","cmc":"290 µA/A +500 µA"},{"name":"45 Hz až 1 kHz","range":"1,2 A až 3,1 A","cmc":"190 µA/A +300 µA"},{"name":"1 kHz až 5 kHz","range":"1,2 A až 3,1 A","cmc":"290 µA/A +300 µA"},{"name":"5 kHz až 10 kHz","range":"1,2 A až 3,1 A","cmc":"1 900 µA/A +500 µA"},{"name":"3 Hz až 45 Hz","range":"3,1 A až 12 A","cmc":"290 µA/A +1 000 µA"},{"name":"45 Hz až 1 kHz","range":"3,1 A až 12 A","cmc":"230 µA/A +500 µA"},{"name":"1 kHz až 5 kHz","range":"3,1 A až 12 A","cmc":"290 µA/A +800 µA"},{"name":"5 kHz až 10 kHz","range":"3,1 A až 12 A","cmc":"1 900 µA/A +1 000 µA"},{"name":"3 Hz až 45 Hz","range":"12 A až 30.2 A","cmc":"780 µA/A +10 mA"},{"name":"45 Hz až 1 kHz","range":"12 A až 30.2 A","cmc":"540 µA/A +8 mA"},{"name":"1 kHz až 5 kHz","range":"12 A až 30.2 A","cmc":"3 900 µA/A +8 mA"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation by a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation by a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n3 Hz do 5 kHz od 0,010 mA do 0,12 mA CMC 190 µA/A +10 nA\n5 kHz do 10 kHz od 0,010 mA do 0,12 mA CMC 1 200 µA/A +40 nA\n10 kHz do 30 kHz od 0,010 mA do 0,12 mA CMC 3 900 µA/A +1 µA\n3 Hz do 5 kHz od 0,12 mA do 1,2 mA CMC 190 µA/A +100 nA\n5 kHz do 10 kHz od 0,12 mA do 1,2 mA CMC 1 200 µA/A +100 nA\n10 kHz do 30 kHz od 0,12 mA do 1,2 mA CMC 3 900 µA/A +5 µA\n3 Hz do 5 kHz od 1,2 mA do 12 mA CMC 190 µA/A +1 µA\n5 kHz do 10 kHz od 1,2 mA do 12 mA CMC 1 200 µA/A +1 µA\n10 kHz do 30 kHz od 1,2 mA do 12 mA CMC 3 900 µA/A +10 µA\n3 Hz do 45 Hz od 12 mA do 120 mA CMC 190 µA/A +10 µA\n45 Hz do 1 kHz od 12 mA do 120 mA CMC 120 µA/A +5 µA\n1 kHz do 5 kHz od 12 mA do 120 mA CMC 190 µA/A +8 µA\n5 kHz do 10 kHz od 12 mA do 120 mA CMC 1 200 µA/A +10 µA\n10 kHz do 30 kHz od 12 mA do 120 mA CMC 3 900 µA/A +100 µA\n3 Hz do 45 Hz od 120 mA do 1,2 A CMC 190 µA/A +100 µA\n45 Hz do 1 kHz od 120 mA do 1,2 A CMC 120 µA/A +50 µA\n1 kHz do 5 kHz od 120 mA do 1,2 A CMC 190 µA/A +80 µA\n5 kHz do 10 kHz od 120 mA do 1,2 A CMC 1 900 µA/A +300 µA\n10 kHz do 30 kHz od 120 mA do 1,2 A CMC 3 900 µA/A +300 µA\n3 Hz do 45 Hz od 1,2 A do 3,1 A CMC 290 µA/A +500 µA\n45 Hz do 1 kHz od 1,2 A do 3,1 A CMC 190 µA/A +300 µA\n1 kHz do 5 kHz od 1,2 A do 3,1 A CMC 290 µA/A +300 µA\n5 kHz do 10 kHz od 1,2 A do 3,1 A CMC 1 900 µA/A +500 µA\n3 Hz do 45 Hz od 3,1 A do 12 A CMC 290 µA/A +1 000 µA\n45 Hz do 1 kHz od 3,1 A do 12 A CMC 230 µA/A +500 µA\n1 kHz do 5 kHz od 3,1 A do 12 A CMC 290 µA/A +800 µA\n5 kHz do 10 kHz od 3,1 A do 12 A CMC 1 900 µA/A +1 000 µA\n3 Hz do 45 Hz od 12 A do 30.2 A CMC 780 µA/A +10 mA\n45 Hz do 1 kHz od 12 A do 30.2 A CMC 540 µA/A +8 mA\n1 kHz do 5 kHz od 12 A do 30.2 A CMC 3 900 µA/A +8 mA\nBezpośrednie generowanie kalibratorem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki prądu przemiennego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 3 Hz do 5 kHz od 0,010 mA do 0,12 mA CMC 190 µA/A +10 nA 5 kHz do 10 kHz od 0,010 mA do 0,12 mA CMC 1 200 µA/A +40 nA 10 kHz do 30 kHz od 0,010 mA do 0,12 mA CMC 3 900 µA/A +1 µA 3 Hz do 5 kHz od 0,12 mA do 1,2 mA CMC 190 µA/A +100 nA 5 kHz do 10 kHz od 0,12 mA do 1,2 mA CMC 1 200 µA/A +100 nA 10 kHz do 30 kHz od 0,12 mA do 1,2 mA CMC 3 900 µA/A +5 µA 3 Hz do 5 kHz od 1,2 mA do 12 mA CMC 190 µA/A +1 µA 5 kHz do 10 kHz od 1,2 mA do 12 mA CMC 1 200 µA/A +1 µA 10 kHz do 30 kHz od 1,2 mA do 12 mA CMC 3 900 µA/A +10 µA 3 Hz do 45 Hz od 12 mA do 120 mA CMC 190 µA/A +10 µA 45 Hz do 1 kHz od 12 mA do 120 mA CMC 120 µA/A +5 µA 1 kHz do 5 kHz od 12 mA do 120 mA CMC 190 µA/A +8 µA 5 kHz do 10 kHz od 12 mA do 120 mA CMC 1 200 µA/A +10 µA 10 kHz do 30 kHz od 12 mA do 120 mA CMC 3 900 µA/A +100 µA 3 Hz do 45 Hz od 120 mA do 1,2 A CMC 190 µA/A +100 µA 45 Hz do 1 kHz od 120 mA do 1,2 A CMC 120 µA/A +50 µA 1 kHz do 5 kHz od 120 mA do 1,2 A CMC 190 µA/A +80 µA 5 kHz do 10 kHz od 120 mA do 1,2 A CMC 1 900 µA/A +300 µA 10 kHz do 30 kHz od 120 mA do 1,2 A CMC 3 900 µA/A +300 µA 3 Hz do 45 Hz od 1,2 A do 3,1 A CMC 290 µA/A +500 µA 45 Hz do 1 kHz od 1,2 A do 3,1 A CMC 190 µA/A +300 µA 1 kHz do 5 kHz od 1,2 A do 3,1 A CMC 290 µA/A +300 µA 5 kHz do 10 kHz od 1,2 A do 3,1 A CMC 1 900 µA/A +500 µA 3 Hz do 45 Hz od 3,1 A do 12 A CMC 290 µA/A +1 000 µA 45 Hz do 1 kHz od 3,1 A do 12 A CMC 230 µA/A +500 µA 1 kHz do 5 kHz od 3,1 A do 12 A CMC 290 µA/A +800 µA 5 kHz do 10 kHz od 3,1 A do 12 A CMC 1 900 µA/A +1 000 µA 3 Hz do 45 Hz od 12 A do 30.2 A CMC 780 µA/A +10 mA 45 Hz do 1 kHz od 12 A do 30.2 A CMC 540 µA/A +8 mA 1 kHz do 5 kHz od 12 A do 30.2 A CMC 3 900 µA/A +8 mA Střídavý proud / měřidla střídavého proudu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 3 Hz až 5 kHz 0,010 mA až 0,12 mA CMC 190 µA/A +10 nA 5 kHz až 10 kHz 0,010 mA až 0,12 mA CMC 1 200 µA/A +40 nA 10 kHz až 30 kHz 0,010 mA až 0,12 mA CMC 3 900 µA/A +1 µA 3 Hz až 5 kHz 0,12 mA až 1,2 mA CMC 190 µA/A +100 nA 5 kHz až 10 kHz 0,12 mA až 1,2 mA CMC 1 200 µA/A +100 nA 10 kHz až 30 kHz 0,12 mA až 1,2 mA CMC 3 900 µA/A +5 µA 3 Hz až 5 kHz 1,2 mA až 12 mA CMC 190 µA/A +1 µA 5 kHz až 10 kHz 1,2 mA až 12 mA CMC 1 200 µA/A +1 µA 10 kHz až 30 kHz 1,2 mA až 12 mA CMC 3 900 µA/A +10 µA 3 Hz až 45 Hz 12 mA až 120 mA CMC 190 µA/A +10 µA 45 Hz až 1 kHz 12 mA až 120 mA CMC 120 µA/A +5 µA 1 kHz až 5 kHz 12 mA až 120 mA CMC 190 µA/A +8 µA 5 kHz až 10 kHz 12 mA až 120 mA CMC 1 200 µA/A +10 µA 10 kHz až 30 kHz 12 mA až 120 mA CMC 3 900 µA/A +100 µA 3 Hz až 45 Hz 120 mA až 1,2 A CMC 190 µA/A +100 µA 45 Hz až 1 kHz 120 mA až 1,2 A CMC 120 µA/A +50 µA 1 kHz až 5 kHz 120 mA až 1,2 A CMC 190 µA/A +80 µA 5 kHz až 10 kHz 120 mA až 1,2 A CMC 1 900 µA/A +300 µA 10 kHz až 30 kHz 120 mA až 1,2 A CMC 3 900 µA/A +300 µA 3 Hz až 45 Hz 1,2 A až 3,1 A CMC 290 µA/A +500 µA 45 Hz až 1 kHz 1,2 A až 3,1 A CMC 190 µA/A +300 µA 1 kHz až 5 kHz 1,2 A až 3,1 A CMC 290 µA/A +300 µA 5 kHz až 10 kHz 1,2 A až 3,1 A CMC 1 900 µA/A +500 µA 3 Hz až 45 Hz 3,1 A až 12 A CMC 290 µA/A +1 000 µA 45 Hz až 1 kHz 3,1 A až 12 A CMC 230 µA/A +500 µA 1 kHz až 5 kHz 3,1 A až 12 A CMC 290 µA/A +800 µA 5 kHz až 10 kHz 3,1 A až 12 A CMC 1 900 µA/A +1 000 µA 3 Hz až 45 Hz 12 A až 30.2 A CMC 780 µA/A +10 mA 45 Hz až 1 kHz 12 A až 30.2 A CMC 540 µA/A +8 mA 1 kHz až 5 kHz 12 A až 30.2 A CMC 3 900 µA/A +8 mA VKP01/05 VKP02/05 Prad przemienny / mierniki pradu przemiennego, kalibratory, multimetry, mierniki cegowe, mierniki do badan instalacji, testery wielofunkcyjne, mierniki rezystancji uziemien, mierniki uziemien, testery elektronarzedzi Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 3 Hz do 5 kHz od 0,010 mA do 0,12 mA CMC 190 µA/A +10 nA 5 kHz do 10 kHz od 0,010 mA do 0,12 mA CMC 1 200 µA/A +40 nA 10 kHz do 30 kHz od 0,010 mA do 0,12 mA CMC 3 900 µA/A +1 µA 3 Hz do 5 kHz od 0,12 mA do 1,2 mA CMC 190 µA/A +100 nA 5 kHz do 10 kHz od 0,12 mA do 1,2 mA CMC 1 200 µA/A +100 nA 10 kHz do 30 kHz od 0,12 mA do 1,2 mA CMC 3 900 µA/A +5 µA 3 Hz do 5 kHz od 1,2 mA do 12 mA CMC 190 µA/A +1 µA 5 kHz do 10 kHz od 1,2 mA do 12 mA CMC 1 200 µA/A +1 µA 10 kHz do 30 kHz od 1,2 mA do 12 mA CMC 3 900 µA/A +10 µA 3 Hz do 45 Hz od 12 mA do 120 mA CMC 190 µA/A +10 µA 45 Hz do 1 kHz od 12 mA do 120 mA CMC 120 µA/A +5 µA 1 kHz do 5 kHz od 12 mA do 120 mA CMC 190 µA/A +8 µA 5 kHz do 10 kHz od 12 mA do 120 mA CMC 1 200 µA/A +10 µA 10 kHz do 30 kHz od 12 mA do 120 mA CMC 3 900 µA/A +100 µA 3 Hz do 45 Hz od 120 mA do 1,2 A CMC 190 µA/A +100 µA 45 Hz do 1 kHz od 120 mA do 1,2 A CMC 120 µA/A +50 µA 1 kHz do 5 kHz od 120 mA do 1,2 A CMC 190 µA/A +80 µA 5 kHz do 10 kHz od 120 mA do 1,2 A CMC 1 900 µA/A +300 µA 10 kHz do 30 kHz od 120 mA do 1,2 A CMC 3 900 µA/A +300 µA 3 Hz do 45 Hz od 1,2 A do 3,1 A CMC 290 µA/A +500 µA 45 Hz do 1 kHz od 1,2 A do 3,1 A CMC 190 µA/A +300 µA 1 kHz do 5 kHz od 1,2 A do 3,1 A CMC 290 µA/A +300 µA 5 kHz do 10 kHz od 1,2 A do 3,1 A CMC 1 900 µA/A +500 µA 3 Hz do 45 Hz od 3,1 A do 12 A CMC 290 µA/A +1 000 µA 45 Hz do 1 kHz od 3,1 A do 12 A CMC 230 µA/A +500 µA 1 kHz do 5 kHz od 3,1 A do 12 A CMC 290 µA/A +800 µA 5 kHz do 10 kHz od 3,1 A do 12 A CMC 1 900 µA/A +1 000 µA 3 Hz do 45 Hz od 12 A do 30.2 A CMC 780 µA/A +10 mA 45 Hz do 1 kHz od 12 A do 30.2 A CMC 540 µA/A +8 mA 1 kHz do 5 kHz od 12 A do 30.2 A CMC 3 900 µA/A +8 mA Stridavy proud / meridla stridaveho proudu, kalibratory, multimetry, klestova meridla, revizni meridla, multifunkcni testery, merice zemniho odporu, meridla uzemneni, testery rucniho naradi Kalibrace – elektricke veliciny Prime generovani kalibratorem 3 Hz az 5 kHz 0,010 mA az 0,12 mA CMC 190 µA/A +10 nA 5 kHz az 10 kHz 0,010 mA az 0,12 mA CMC 1 200 µA/A +40 nA 10 kHz az 30 kHz 0,010 mA az 0,12 mA CMC 3 900 µA/A +1 µA 3 Hz az 5 kHz 0,12 mA az 1,2 mA CMC 190 µA/A +100 nA 5 kHz az 10 kHz 0,12 mA az 1,2 mA CMC 1 200 µA/A +100 nA 10 kHz az 30 kHz 0,12 mA az 1,2 mA CMC 3 900 µA/A +5 µA 3 Hz az 5 kHz 1,2 mA az 12 mA CMC 190 µA/A +1 µA 5 kHz az 10 kHz 1,2 mA az 12 mA CMC 1 200 µA/A +1 µA 10 kHz az 30 kHz 1,2 mA az 12 mA CMC 3 900 µA/A +10 µA 3 Hz az 45 Hz 12 mA az 120 mA CMC 190 µA/A +10 µA 45 Hz az 1 kHz 12 mA az 120 mA CMC 120 µA/A +5 µA 1 kHz az 5 kHz 12 mA az 120 mA CMC 190 µA/A +8 µA 5 kHz az 10 kHz 12 mA az 120 mA CMC 1 200 µA/A +10 µA 10 kHz az 30 kHz 12 mA az 120 mA CMC 3 900 µA/A +100 µA 3 Hz az 45 Hz 120 mA az 1,2 A CMC 190 µA/A +100 µA 45 Hz az 1 kHz 120 mA az 1,2 A CMC 120 µA/A +50 µA 1 kHz az 5 kHz 120 mA az 1,2 A CMC 190 µA/A +80 µA 5 kHz az 10 kHz 120 mA az 1,2 A CMC 1 900 µA/A +300 µA 10 kHz az 30 kHz 120 mA az 1,2 A CMC 3 900 µA/A +300 µA 3 Hz az 45 Hz 1,2 A az 3,1 A CMC 290 µA/A +500 µA 45 Hz az 1 kHz 1,2 A az 3,1 A CMC 190 µA/A +300 µA 1 kHz az 5 kHz 1,2 A az 3,1 A CMC 290 µA/A +300 µA 5 kHz az 10 kHz 1,2 A az 3,1 A CMC 1 900 µA/A +500 µA 3 Hz az 45 Hz 3,1 A az 12 A CMC 290 µA/A +1 000 µA 45 Hz az 1 kHz 3,1 A az 12 A CMC 230 µA/A +500 µA 1 kHz az 5 kHz 3,1 A az 12 A CMC 290 µA/A +800 µA 5 kHz az 10 kHz 3,1 A az 12 A CMC 1 900 µA/A +1 000 µA 3 Hz az 45 Hz 12 A az 30.2 A CMC 780 µA/A +10 mA 45 Hz az 1 kHz 12 A az 30.2 A CMC 540 µA/A +8 mA 1 kHz az 5 kHz 12 A az 30.2 A CMC 3 900 µA/A +8 mA VKP01/05 VKP02/05","search_en":"AC current / AC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers Calibration – electrical quantities Direct generation by a calibrator 3 Hz to 5 kHz 0,010 mA to 0,12 mA CMC 190 µA/A +10 nA 5 kHz to 10 kHz 0,010 mA to 0,12 mA CMC 1 200 µA/A +40 nA 10 kHz to 30 kHz 0,010 mA to 0,12 mA CMC 3 900 µA/A +1 µA 3 Hz to 5 kHz 0,12 mA to 1,2 mA CMC 190 µA/A +100 nA 5 kHz to 10 kHz 0,12 mA to 1,2 mA CMC 1 200 µA/A +100 nA 10 kHz to 30 kHz 0,12 mA to 1,2 mA CMC 3 900 µA/A +5 µA 3 Hz to 5 kHz 1,2 mA to 12 mA CMC 190 µA/A +1 µA 5 kHz to 10 kHz 1,2 mA to 12 mA CMC 1 200 µA/A +1 µA 10 kHz to 30 kHz 1,2 mA to 12 mA CMC 3 900 µA/A +10 µA 3 Hz to 45 Hz 12 mA to 120 mA CMC 190 µA/A +10 µA 45 Hz to 1 kHz 12 mA to 120 mA CMC 120 µA/A +5 µA 1 kHz to 5 kHz 12 mA to 120 mA CMC 190 µA/A +8 µA 5 kHz to 10 kHz 12 mA to 120 mA CMC 1 200 µA/A +10 µA 10 kHz to 30 kHz 12 mA to 120 mA CMC 3 900 µA/A +100 µA 3 Hz to 45 Hz 120 mA to 1,2 A CMC 190 µA/A +100 µA 45 Hz to 1 kHz 120 mA to 1,2 A CMC 120 µA/A +50 µA 1 kHz to 5 kHz 120 mA to 1,2 A CMC 190 µA/A +80 µA 5 kHz to 10 kHz 120 mA to 1,2 A CMC 1 900 µA/A +300 µA 10 kHz to 30 kHz 120 mA to 1,2 A CMC 3 900 µA/A +300 µA 3 Hz to 45 Hz 1,2 A to 3,1 A CMC 290 µA/A +500 µA 45 Hz to 1 kHz 1,2 A to 3,1 A CMC 190 µA/A +300 µA 1 kHz to 5 kHz 1,2 A to 3,1 A CMC 290 µA/A +300 µA 5 kHz to 10 kHz 1,2 A to 3,1 A CMC 1 900 µA/A +500 µA 3 Hz to 45 Hz 3,1 A to 12 A CMC 290 µA/A +1 000 µA 45 Hz to 1 kHz 3,1 A to 12 A CMC 230 µA/A +500 µA 1 kHz to 5 kHz 3,1 A to 12 A CMC 290 µA/A +800 µA 5 kHz to 10 kHz 3,1 A to 12 A CMC 1 900 µA/A +1 000 µA 3 Hz to 45 Hz 12 A to 30.2 A CMC 780 µA/A +10 mA 45 Hz to 1 kHz 12 A to 30.2 A CMC 540 µA/A +8 mA 1 kHz to 5 kHz 12 A to 30.2 A CMC 3 900 µA/A +8 mA VKP01/05 VKP02/05","search_zh":"交流电流 / 交流电流表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪 校准 – 电学量 用校准器直接产生 3 Hz 至 5 kHz 0,010 mA 至 0,12 mA CMC 190 µA/A +10 nA 5 kHz 至 10 kHz 0,010 mA 至 0,12 mA CMC 1 200 µA/A +40 nA 10 kHz 至 30 kHz 0,010 mA 至 0,12 mA CMC 3 900 µA/A +1 µA 3 Hz 至 5 kHz 0,12 mA 至 1,2 mA CMC 190 µA/A +100 nA 5 kHz 至 10 kHz 0,12 mA 至 1,2 mA CMC 1 200 µA/A +100 nA 10 kHz 至 30 kHz 0,12 mA 至 1,2 mA CMC 3 900 µA/A +5 µA 3 Hz 至 5 kHz 1,2 mA 至 12 mA CMC 190 µA/A +1 µA 5 kHz 至 10 kHz 1,2 mA 至 12 mA CMC 1 200 µA/A +1 µA 10 kHz 至 30 kHz 1,2 mA 至 12 mA CMC 3 900 µA/A +10 µA 3 Hz 至 45 Hz 12 mA 至 120 mA CMC 190 µA/A +10 µA 45 Hz 至 1 kHz 12 mA 至 120 mA CMC 120 µA/A +5 µA 1 kHz 至 5 kHz 12 mA 至 120 mA CMC 190 µA/A +8 µA 5 kHz 至 10 kHz 12 mA 至 120 mA CMC 1 200 µA/A +10 µA 10 kHz 至 30 kHz 12 mA 至 120 mA CMC 3 900 µA/A +100 µA 3 Hz 至 45 Hz 120 mA 至 1,2 A CMC 190 µA/A +100 µA 45 Hz 至 1 kHz 120 mA 至 1,2 A CMC 120 µA/A +50 µA 1 kHz 至 5 kHz 120 mA 至 1,2 A CMC 190 µA/A +80 µA 5 kHz 至 10 kHz 120 mA 至 1,2 A CMC 1 900 µA/A +300 µA 10 kHz 至 30 kHz 120 mA 至 1,2 A CMC 3 900 µA/A +300 µA 3 Hz 至 45 Hz 1,2 A 至 3,1 A CMC 290 µA/A +500 µA 45 Hz 至 1 kHz 1,2 A 至 3,1 A CMC 190 µA/A +300 µA 1 kHz 至 5 kHz 1,2 A 至 3,1 A CMC 290 µA/A +300 µA 5 kHz 至 10 kHz 1,2 A 至 3,1 A CMC 1 900 µA/A +500 µA 3 Hz 至 45 Hz 3,1 A 至 12 A CMC 290 µA/A +1 000 µA 45 Hz 至 1 kHz 3,1 A 至 12 A CMC 230 µA/A +500 µA 1 kHz 至 5 kHz 3,1 A 至 12 A CMC 290 µA/A +800 µA 5 kHz 至 10 kHz 3,1 A 至 12 A CMC 1 900 µA/A +1 000 µA 3 Hz 至 45 Hz 12 A 至 30.2 A CMC 780 µA/A +10 mA 45 Hz 至 1 kHz 12 A 至 30.2 A CMC 540 µA/A +8 mA 1 kHz 至 5 kHz 12 A 至 30.2 A CMC 3 900 µA/A +8 mA VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67f8e2f12be80c47f18e6aa9","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / mierniki prądu przemiennego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi","test_object_en":"AC current / AC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers","test_object_zh":"交流电流 / 交流电流表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪","test_object_cs":"Střídavý proud / měřidla střídavého proudu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 10 A do 16,5 A","cmc":"0,56 % +30 mA"},{"name":"65 Hz do 440 Hz","range":"od 10 A do 16,5 A","cmc":"1,00 % +30 mA"},{"name":"45 Hz do 65 Hz","range":"od 16,5 A do 150 A","cmc":"0,56 % +0,25 A"},{"name":"65 Hz do 440 Hz","range":"od 16,5 A do 150 A","cmc":"1,00 % +0,25 A"},{"name":"45 Hz do 65 Hz","range":"od 150 A do 1000 A","cmc":"0,56 % +0,9 A"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"10 A to 16,5 A","cmc":"0,56 % +30 mA"},{"name":"65 Hz to 440 Hz","range":"10 A to 16,5 A","cmc":"1,00 % +30 mA"},{"name":"45 Hz to 65 Hz","range":"16,5 A to 150 A","cmc":"0,56 % +0,25 A"},{"name":"65 Hz to 440 Hz","range":"16,5 A to 150 A","cmc":"1,00 % +0,25 A"},{"name":"45 Hz to 65 Hz","range":"150 A to 1000 A","cmc":"0,56 % +0,9 A"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"10 A 至 16,5 A","cmc":"0,56 % +30 mA"},{"name":"65 Hz 至 440 Hz","range":"10 A 至 16,5 A","cmc":"1,00 % +30 mA"},{"name":"45 Hz 至 65 Hz","range":"16,5 A 至 150 A","cmc":"0,56 % +0,25 A"},{"name":"65 Hz 至 440 Hz","range":"16,5 A 至 150 A","cmc":"1,00 % +0,25 A"},{"name":"45 Hz 至 65 Hz","range":"150 A 至 1000 A","cmc":"0,56 % +0,9 A"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"10 A až 16,5 A","cmc":"0,56 % +30 mA"},{"name":"65 Hz až 440 Hz","range":"10 A až 16,5 A","cmc":"1,00 % +30 mA"},{"name":"45 Hz až 65 Hz","range":"16,5 A až 150 A","cmc":"0,56 % +0,25 A"},{"name":"65 Hz až 440 Hz","range":"16,5 A až 150 A","cmc":"1,00 % +0,25 A"},{"name":"45 Hz až 65 Hz","range":"150 A až 1000 A","cmc":"0,56 % +0,9 A"}],"technique":"Pośrednie generowanie kalibratorem z symulacją prądu cewkami prądowymi","technique_en":"Indirect generation by a calibrator with current simulation by current coils","technique_zh":"用校准器以电流线圈模拟电流间接产生","technique_cs":"Nepřímé generování kalibrátorem se simulací proudu proudovými cívkami","techniques":["Pośrednie generowanie kalibratorem z symulacją prądu cewkami prądowymi"],"techniques_en":["Indirect generation by a calibrator with current simulation by current coils"],"techniques_zh":["用校准器以电流线圈模拟电流间接产生"],"techniques_cs":["Nepřímé generování kalibrátorem se simulací proudu proudovými cívkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n45 Hz do 65 Hz od 10 A do 16,5 A CMC 0,56 % +30 mA\n65 Hz do 440 Hz od 10 A do 16,5 A CMC 1,00 % +30 mA\n45 Hz do 65 Hz od 16,5 A do 150 A CMC 0,56 % +0,25 A\n65 Hz do 440 Hz od 16,5 A do 150 A CMC 1,00 % +0,25 A\n45 Hz do 65 Hz od 150 A do 1000 A CMC 0,56 % +0,9 A\nPośrednie generowanie kalibratorem z symulacją prądu cewkami prądowymi","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki prądu przemiennego, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi Wzorcowanie – wielkości elektryczne Pośrednie generowanie kalibratorem z symulacją prądu cewkami prądowymi 45 Hz do 65 Hz od 10 A do 16,5 A CMC 0,56 % +30 mA 65 Hz do 440 Hz od 10 A do 16,5 A CMC 1,00 % +30 mA 45 Hz do 65 Hz od 16,5 A do 150 A CMC 0,56 % +0,25 A 65 Hz do 440 Hz od 16,5 A do 150 A CMC 1,00 % +0,25 A 45 Hz do 65 Hz od 150 A do 1000 A CMC 0,56 % +0,9 A Střídavý proud / měřidla střídavého proudu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí Kalibrace – elektrické veličiny Nepřímé generování kalibrátorem se simulací proudu proudovými cívkami 45 Hz až 65 Hz 10 A až 16,5 A CMC 0,56 % +30 mA 65 Hz až 440 Hz 10 A až 16,5 A CMC 1,00 % +30 mA 45 Hz až 65 Hz 16,5 A až 150 A CMC 0,56 % +0,25 A 65 Hz až 440 Hz 16,5 A až 150 A CMC 1,00 % +0,25 A 45 Hz až 65 Hz 150 A až 1000 A CMC 0,56 % +0,9 A VKP01/05 VKP02/05 Prad przemienny / mierniki pradu przemiennego, kalibratory, multimetry, mierniki cegowe, mierniki do badan instalacji, testery wielofunkcyjne, mierniki rezystancji uziemien, mierniki uziemien, testery elektronarzedzi Wzorcowanie – wielkosci elektryczne Posrednie generowanie kalibratorem z symulacja pradu cewkami pradowymi 45 Hz do 65 Hz od 10 A do 16,5 A CMC 0,56 % +30 mA 65 Hz do 440 Hz od 10 A do 16,5 A CMC 1,00 % +30 mA 45 Hz do 65 Hz od 16,5 A do 150 A CMC 0,56 % +0,25 A 65 Hz do 440 Hz od 16,5 A do 150 A CMC 1,00 % +0,25 A 45 Hz do 65 Hz od 150 A do 1000 A CMC 0,56 % +0,9 A Stridavy proud / meridla stridaveho proudu, kalibratory, multimetry, klestova meridla, revizni meridla, multifunkcni testery, merice zemniho odporu, meridla uzemneni, testery rucniho naradi Kalibrace – elektricke veliciny Neprime generovani kalibratorem se simulaci proudu proudovymi civkami 45 Hz az 65 Hz 10 A az 16,5 A CMC 0,56 % +30 mA 65 Hz az 440 Hz 10 A az 16,5 A CMC 1,00 % +30 mA 45 Hz az 65 Hz 16,5 A az 150 A CMC 0,56 % +0,25 A 65 Hz az 440 Hz 16,5 A az 150 A CMC 1,00 % +0,25 A 45 Hz az 65 Hz 150 A az 1000 A CMC 0,56 % +0,9 A VKP01/05 VKP02/05","search_en":"AC current / AC current meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers Calibration – electrical quantities Indirect generation by a calibrator with current simulation by current coils 45 Hz to 65 Hz 10 A to 16,5 A CMC 0,56 % +30 mA 65 Hz to 440 Hz 10 A to 16,5 A CMC 1,00 % +30 mA 45 Hz to 65 Hz 16,5 A to 150 A CMC 0,56 % +0,25 A 65 Hz to 440 Hz 16,5 A to 150 A CMC 1,00 % +0,25 A 45 Hz to 65 Hz 150 A to 1000 A CMC 0,56 % +0,9 A VKP01/05 VKP02/05","search_zh":"交流电流 / 交流电流表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪 校准 – 电学量 用校准器以电流线圈模拟电流间接产生 45 Hz 至 65 Hz 10 A 至 16,5 A CMC 0,56 % +30 mA 65 Hz 至 440 Hz 10 A 至 16,5 A CMC 1,00 % +30 mA 45 Hz 至 65 Hz 16,5 A 至 150 A CMC 0,56 % +0,25 A 65 Hz 至 440 Hz 16,5 A 至 150 A CMC 1,00 % +0,25 A 45 Hz 至 65 Hz 150 A 至 1000 A CMC 0,56 % +0,9 A VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"77461e41c40e0930619886d4","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"4","test_object":"Prąd upływu / mierniki do badań instalacji, testery wielofunkcyjne, mierniki prądów upływu","test_object_en":"Leakage current / installation testers, multifunction testers, leakage current meters","test_object_zh":"泄漏电流 / 电气安装测试仪、多功能测试仪、泄漏电流测试仪","test_object_cs":"Unikající proud / revizní měřidla, multifunkční testery, měřidla unikajících proudů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz; pasywny","range":"od 100 µA do 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz; różnicowy","range":"od 100 µA do 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz; zastępczy","range":"od 100 µA do 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz; aktywny","range":"od 100 µA do 30 mA","cmc":"0,3 % +1 µA"}],"parameters_en":[{"name":"50 Hz; passive","range":"100 µA to 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz; differential","range":"100 µA to 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz; substitute","range":"100 µA to 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz; active","range":"100 µA to 30 mA","cmc":"0,3 % +1 µA"}],"parameters_zh":[{"name":"50 Hz；无源","range":"100 µA 至 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz；差分","range":"100 µA 至 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz；替代","range":"100 µA 至 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz；有源","range":"100 µA 至 30 mA","cmc":"0,3 % +1 µA"}],"parameters_cs":[{"name":"50 Hz; pasivní","range":"100 µA až 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz; diferenciální","range":"100 µA až 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz; substituční","range":"100 µA až 30 mA","cmc":"0,3 % +2 µA"},{"name":"50 Hz; aktivní","range":"100 µA až 30 mA","cmc":"0,3 % +1 µA"}],"technique":"Bezpośrednie porównanie z kalibratorem mierników do badań instalacji","technique_en":"Direct comparison with an installation tester calibrator","technique_zh":"与电气安装测试仪校准器直接比较","technique_cs":"Přímé porovnání s kalibrátorem revizních přístrojů","techniques":["Bezpośrednie porównanie z kalibratorem mierników do badań instalacji"],"techniques_en":["Direct comparison with an installation tester calibrator"],"techniques_zh":["与电气安装测试仪校准器直接比较"],"techniques_cs":["Přímé porovnání s kalibrátorem revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz; pasywny od 100 µA do 30 mA CMC 0,3 % +2 µA\n50 Hz; różnicowy od 100 µA do 30 mA CMC 0,3 % +2 µA\n50 Hz; zastępczy od 100 µA do 30 mA CMC 0,3 % +2 µA\n50 Hz; aktywny od 100 µA do 30 mA CMC 0,3 % +1 µA\nBezpośrednie porównanie z kalibratorem mierników do badań instalacji","reference":"VKP02/05","norm_bases":["VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd upływu / mierniki do badań instalacji, testery wielofunkcyjne, mierniki prądów upływu Wzorcowanie – wielkości elektryczne Bezpośrednie porównanie z kalibratorem mierników do badań instalacji 50 Hz; pasywny od 100 µA do 30 mA CMC 0,3 % +2 µA 50 Hz; różnicowy od 100 µA do 30 mA CMC 0,3 % +2 µA 50 Hz; zastępczy od 100 µA do 30 mA CMC 0,3 % +2 µA 50 Hz; aktywny od 100 µA do 30 mA CMC 0,3 % +1 µA Unikající proud / revizní měřidla, multifunkční testery, měřidla unikajících proudů Kalibrace – elektrické veličiny Přímé porovnání s kalibrátorem revizních přístrojů 50 Hz; pasivní 100 µA až 30 mA CMC 0,3 % +2 µA 50 Hz; diferenciální 100 µA až 30 mA CMC 0,3 % +2 µA 50 Hz; substituční 100 µA až 30 mA CMC 0,3 % +2 µA 50 Hz; aktivní 100 µA až 30 mA CMC 0,3 % +1 µA VKP02/05 Prad uplywu / mierniki do badan instalacji, testery wielofunkcyjne, mierniki pradow uplywu Wzorcowanie – wielkosci elektryczne Bezposrednie porownanie z kalibratorem miernikow do badan instalacji 50 Hz; pasywny od 100 µA do 30 mA CMC 0,3 % +2 µA 50 Hz; roznicowy od 100 µA do 30 mA CMC 0,3 % +2 µA 50 Hz; zastepczy od 100 µA do 30 mA CMC 0,3 % +2 µA 50 Hz; aktywny od 100 µA do 30 mA CMC 0,3 % +1 µA Unikajici proud / revizni meridla, multifunkcni testery, meridla unikajicich proudu Kalibrace – elektricke veliciny Prime porovnani s kalibratorem reviznich pristroju 50 Hz; pasivni 100 µA az 30 mA CMC 0,3 % +2 µA 50 Hz; diferencialni 100 µA az 30 mA CMC 0,3 % +2 µA 50 Hz; substitucni 100 µA az 30 mA CMC 0,3 % +2 µA 50 Hz; aktivni 100 µA az 30 mA CMC 0,3 % +1 µA VKP02/05","search_en":"Leakage current / installation testers, multifunction testers, leakage current meters Calibration – electrical quantities Direct comparison with an installation tester calibrator 50 Hz; passive 100 µA to 30 mA CMC 0,3 % +2 µA 50 Hz; differential 100 µA to 30 mA CMC 0,3 % +2 µA 50 Hz; substitute 100 µA to 30 mA CMC 0,3 % +2 µA 50 Hz; active 100 µA to 30 mA CMC 0,3 % +1 µA VKP02/05","search_zh":"泄漏电流 / 电气安装测试仪、多功能测试仪、泄漏电流测试仪 校准 – 电学量 与电气安装测试仪校准器直接比较 50 Hz；无源 100 µA 至 30 mA CMC 0,3 % +2 µA 50 Hz；差分 100 µA 至 30 mA CMC 0,3 % +2 µA 50 Hz；替代 100 µA 至 30 mA CMC 0,3 % +2 µA 50 Hz；有源 100 µA 至 30 mA CMC 0,3 % +1 µA VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a44c4429619249911c875c5c","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"4","test_object":"Prąd zadziałania wyłączników różnicowoprądowych / mierniki do badań instalacji, testery wielofunkcyjne, testery wyłączników","test_object_en":"RCD tripping current / installation testers, multifunction testers, RCD testers","test_object_zh":"剩余电流保护器动作电流 / 电气安装测试仪、多功能测试仪、剩余电流保护器测试仪","test_object_cs":"Vybavovací proud chráničů / revizní měřidla, multifunkční testery, testery chráničů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 3 mA do 3 A","cmc":"—"}],"parameters_en":[{"name":"50 Hz","range":"3 mA to 3 A","cmc":"—"}],"parameters_zh":[{"name":"50 Hz","range":"3 mA 至 3 A","cmc":"—"}],"parameters_cs":[{"name":"50 Hz","range":"3 mA až 3 A","cmc":"—"}],"technique":"Porównanie kalibratorem mierników do badań instalacji","technique_en":"Comparison by an installation tester calibrator","technique_zh":"用电气安装测试仪校准器比较","technique_cs":"Porovnání kalibrátorem revizních přístrojů","techniques":["Porównanie kalibratorem mierników do badań instalacji"],"techniques_en":["Comparison by an installation tester calibrator"],"techniques_zh":["用电气安装测试仪校准器比较"],"techniques_cs":["Porovnání kalibrátorem revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 3 mA do 3 A CMC —\nPorównanie kalibratorem mierników do badań instalacji","reference":"VKP02/05","norm_bases":["VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd zadziałania wyłączników różnicowoprądowych / mierniki do badań instalacji, testery wielofunkcyjne, testery wyłączników Wzorcowanie – wielkości elektryczne Porównanie kalibratorem mierników do badań instalacji 50 Hz od 3 mA do 3 A CMC — Vybavovací proud chráničů / revizní měřidla, multifunkční testery, testery chráničů Kalibrace – elektrické veličiny Porovnání kalibrátorem revizních přístrojů 50 Hz 3 mA až 3 A CMC — VKP02/05 Prad zadzialania wylacznikow roznicowopradowych / mierniki do badan instalacji, testery wielofunkcyjne, testery wylacznikow Wzorcowanie – wielkosci elektryczne Porownanie kalibratorem miernikow do badan instalacji 50 Hz od 3 mA do 3 A CMC — Vybavovaci proud chranicu / revizni meridla, multifunkcni testery, testery chranicu Kalibrace – elektricke veliciny Porovnani kalibratorem reviznich pristroju 50 Hz 3 mA az 3 A CMC — VKP02/05","search_en":"RCD tripping current / installation testers, multifunction testers, RCD testers Calibration – electrical quantities Comparison by an installation tester calibrator 50 Hz 3 mA to 3 A CMC — VKP02/05","search_zh":"剩余电流保护器动作电流 / 电气安装测试仪、多功能测试仪、剩余电流保护器测试仪 校准 – 电学量 用电气安装测试仪校准器比较 50 Hz 3 mA 至 3 A CMC — VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a069867ef12550662d785469","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / źródła prądu przemiennego","test_object_en":"AC current / AC current sources","test_object_zh":"交流电流 / 交流电流源","test_object_cs":"Střídavý proud / zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 5 kHz","range":"od 10 µA do 100 µA","cmc":"0,15 % +0,06 µA"},{"name":"5 kHz do 10 kHz","range":"od 10 µA do 100 µA","cmc":"0,35 % +0,7 µA"},{"name":"10 Hz do 5 kHz","range":"od 100 µA do 1 mA","cmc":"0,1 % +0,4 µA"},{"name":"5 kHz do 10 kHz","range":"od 100 µA do 1 mA","cmc":"0,2 % +2,5 µA"},{"name":"10 Hz do 5 kHz","range":"od 1 mA do 10 mA","cmc":"0,15 % +6 µA"},{"name":"5 kHz do 10 kHz","range":"od 1 mA do 10 mA","cmc":"0,35 % +70 µA"},{"name":"10 Hz do 5 kHz","range":"od 10 mA do 100 mA","cmc":"0,1 % +40 µA"},{"name":"5 kHz do 10 kHz","range":"od 10 mA do 100 mA","cmc":"0,2 % +0,25 mA"},{"name":"10 Hz do 5 kHz","range":"od 100 mA do 400 mA","cmc":"0,1 % +0,1 mA"},{"name":"5 kHz do 10 kHz","range":"od 100 mA do 400 mA","cmc":"0,2 % +0,7 mA"},{"name":"10 Hz do 5 kHz","range":"od 400 mA do 1 A","cmc":"0,1 % +0,4 mA"},{"name":"5 kHz do 10 kHz","range":"od 400 mA do 1 A","cmc":"0,35 % +7 mA"},{"name":"10 Hz do 5 kHz","range":"od 1 A do 3 A","cmc":"0,15 % +1,8 mA"},{"name":"5 kHz do 10 kHz","range":"od 1 A do 3 A","cmc":"0,35 % +21 mA"},{"name":"10 Hz do 5 kHz","range":"od 3 A do 10 A","cmc":"0,15 % +6 mA"},{"name":"5 kHz do 10 kHz","range":"od 3 A do 10 A","cmc":"0,35 % +70 mA"}],"parameters_en":[{"name":"10 Hz to 5 kHz","range":"10 µA to 100 µA","cmc":"0,15 % +0,06 µA"},{"name":"5 kHz to 10 kHz","range":"10 µA to 100 µA","cmc":"0,35 % +0,7 µA"},{"name":"10 Hz to 5 kHz","range":"100 µA to 1 mA","cmc":"0,1 % +0,4 µA"},{"name":"5 kHz to 10 kHz","range":"100 µA to 1 mA","cmc":"0,2 % +2,5 µA"},{"name":"10 Hz to 5 kHz","range":"1 mA to 10 mA","cmc":"0,15 % +6 µA"},{"name":"5 kHz to 10 kHz","range":"1 mA to 10 mA","cmc":"0,35 % +70 µA"},{"name":"10 Hz to 5 kHz","range":"10 mA to 100 mA","cmc":"0,1 % +40 µA"},{"name":"5 kHz to 10 kHz","range":"10 mA to 100 mA","cmc":"0,2 % +0,25 mA"},{"name":"10 Hz to 5 kHz","range":"100 mA to 400 mA","cmc":"0,1 % +0,1 mA"},{"name":"5 kHz to 10 kHz","range":"100 mA to 400 mA","cmc":"0,2 % +0,7 mA"},{"name":"10 Hz to 5 kHz","range":"400 mA to 1 A","cmc":"0,1 % +0,4 mA"},{"name":"5 kHz to 10 kHz","range":"400 mA to 1 A","cmc":"0,35 % +7 mA"},{"name":"10 Hz to 5 kHz","range":"1 A to 3 A","cmc":"0,15 % +1,8 mA"},{"name":"5 kHz to 10 kHz","range":"1 A to 3 A","cmc":"0,35 % +21 mA"},{"name":"10 Hz to 5 kHz","range":"3 A to 10 A","cmc":"0,15 % +6 mA"},{"name":"5 kHz to 10 kHz","range":"3 A to 10 A","cmc":"0,35 % +70 mA"}],"parameters_zh":[{"name":"10 Hz 至 5 kHz","range":"10 µA 至 100 µA","cmc":"0,15 % +0,06 µA"},{"name":"5 kHz 至 10 kHz","range":"10 µA 至 100 µA","cmc":"0,35 % +0,7 µA"},{"name":"10 Hz 至 5 kHz","range":"100 µA 至 1 mA","cmc":"0,1 % +0,4 µA"},{"name":"5 kHz 至 10 kHz","range":"100 µA 至 1 mA","cmc":"0,2 % +2,5 µA"},{"name":"10 Hz 至 5 kHz","range":"1 mA 至 10 mA","cmc":"0,15 % +6 µA"},{"name":"5 kHz 至 10 kHz","range":"1 mA 至 10 mA","cmc":"0,35 % +70 µA"},{"name":"10 Hz 至 5 kHz","range":"10 mA 至 100 mA","cmc":"0,1 % +40 µA"},{"name":"5 kHz 至 10 kHz","range":"10 mA 至 100 mA","cmc":"0,2 % +0,25 mA"},{"name":"10 Hz 至 5 kHz","range":"100 mA 至 400 mA","cmc":"0,1 % +0,1 mA"},{"name":"5 kHz 至 10 kHz","range":"100 mA 至 400 mA","cmc":"0,2 % +0,7 mA"},{"name":"10 Hz 至 5 kHz","range":"400 mA 至 1 A","cmc":"0,1 % +0,4 mA"},{"name":"5 kHz 至 10 kHz","range":"400 mA 至 1 A","cmc":"0,35 % +7 mA"},{"name":"10 Hz 至 5 kHz","range":"1 A 至 3 A","cmc":"0,15 % +1,8 mA"},{"name":"5 kHz 至 10 kHz","range":"1 A 至 3 A","cmc":"0,35 % +21 mA"},{"name":"10 Hz 至 5 kHz","range":"3 A 至 10 A","cmc":"0,15 % +6 mA"},{"name":"5 kHz 至 10 kHz","range":"3 A 至 10 A","cmc":"0,35 % +70 mA"}],"parameters_cs":[{"name":"10 Hz až 5 kHz","range":"10 µA až 100 µA","cmc":"0,15 % +0,06 µA"},{"name":"5 kHz až 10 kHz","range":"10 µA až 100 µA","cmc":"0,35 % +0,7 µA"},{"name":"10 Hz až 5 kHz","range":"100 µA až 1 mA","cmc":"0,1 % +0,4 µA"},{"name":"5 kHz až 10 kHz","range":"100 µA až 1 mA","cmc":"0,2 % +2,5 µA"},{"name":"10 Hz až 5 kHz","range":"1 mA až 10 mA","cmc":"0,15 % +6 µA"},{"name":"5 kHz až 10 kHz","range":"1 mA až 10 mA","cmc":"0,35 % +70 µA"},{"name":"10 Hz až 5 kHz","range":"10 mA až 100 mA","cmc":"0,1 % +40 µA"},{"name":"5 kHz až 10 kHz","range":"10 mA až 100 mA","cmc":"0,2 % +0,25 mA"},{"name":"10 Hz až 5 kHz","range":"100 mA až 400 mA","cmc":"0,1 % +0,1 mA"},{"name":"5 kHz až 10 kHz","range":"100 mA až 400 mA","cmc":"0,2 % +0,7 mA"},{"name":"10 Hz až 5 kHz","range":"400 mA až 1 A","cmc":"0,1 % +0,4 mA"},{"name":"5 kHz až 10 kHz","range":"400 mA až 1 A","cmc":"0,35 % +7 mA"},{"name":"10 Hz až 5 kHz","range":"1 A až 3 A","cmc":"0,15 % +1,8 mA"},{"name":"5 kHz až 10 kHz","range":"1 A až 3 A","cmc":"0,35 % +21 mA"},{"name":"10 Hz až 5 kHz","range":"3 A až 10 A","cmc":"0,15 % +6 mA"},{"name":"5 kHz až 10 kHz","range":"3 A až 10 A","cmc":"0,35 % +70 mA"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement by a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement by a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 5 kHz od 10 µA do 100 µA CMC 0,15 % +0,06 µA\n5 kHz do 10 kHz od 10 µA do 100 µA CMC 0,35 % +0,7 µA\n10 Hz do 5 kHz od 100 µA do 1 mA CMC 0,1 % +0,4 µA\n5 kHz do 10 kHz od 100 µA do 1 mA CMC 0,2 % +2,5 µA\n10 Hz do 5 kHz od 1 mA do 10 mA CMC 0,15 % +6 µA\n5 kHz do 10 kHz od 1 mA do 10 mA CMC 0,35 % +70 µA\n10 Hz do 5 kHz od 10 mA do 100 mA CMC 0,1 % +40 µA\n5 kHz do 10 kHz od 10 mA do 100 mA CMC 0,2 % +0,25 mA\n10 Hz do 5 kHz od 100 mA do 400 mA CMC 0,1 % +0,1 mA\n5 kHz do 10 kHz od 100 mA do 400 mA CMC 0,2 % +0,7 mA\n10 Hz do 5 kHz od 400 mA do 1 A CMC 0,1 % +0,4 mA\n5 kHz do 10 kHz od 400 mA do 1 A CMC 0,35 % +7 mA\n10 Hz do 5 kHz od 1 A do 3 A CMC 0,15 % +1,8 mA\n5 kHz do 10 kHz od 1 A do 3 A CMC 0,35 % +21 mA\n10 Hz do 5 kHz od 3 A do 10 A CMC 0,15 % +6 mA\n5 kHz do 10 kHz od 3 A do 10 A CMC 0,35 % +70 mA\nPomiar bezpośredni multimetrem","reference":"VKP02/05","norm_bases":["VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 10 Hz do 5 kHz od 10 µA do 100 µA CMC 0,15 % +0,06 µA 5 kHz do 10 kHz od 10 µA do 100 µA CMC 0,35 % +0,7 µA 10 Hz do 5 kHz od 100 µA do 1 mA CMC 0,1 % +0,4 µA 5 kHz do 10 kHz od 100 µA do 1 mA CMC 0,2 % +2,5 µA 10 Hz do 5 kHz od 1 mA do 10 mA CMC 0,15 % +6 µA 5 kHz do 10 kHz od 1 mA do 10 mA CMC 0,35 % +70 µA 10 Hz do 5 kHz od 10 mA do 100 mA CMC 0,1 % +40 µA 5 kHz do 10 kHz od 10 mA do 100 mA CMC 0,2 % +0,25 mA 10 Hz do 5 kHz od 100 mA do 400 mA CMC 0,1 % +0,1 mA 5 kHz do 10 kHz od 100 mA do 400 mA CMC 0,2 % +0,7 mA 10 Hz do 5 kHz od 400 mA do 1 A CMC 0,1 % +0,4 mA 5 kHz do 10 kHz od 400 mA do 1 A CMC 0,35 % +7 mA 10 Hz do 5 kHz od 1 A do 3 A CMC 0,15 % +1,8 mA 5 kHz do 10 kHz od 1 A do 3 A CMC 0,35 % +21 mA 10 Hz do 5 kHz od 3 A do 10 A CMC 0,15 % +6 mA 5 kHz do 10 kHz od 3 A do 10 A CMC 0,35 % +70 mA Střídavý proud / zdroje střídavého proudu Kalibrace – elektrické veličiny Přímé měření multimetrem 10 Hz až 5 kHz 10 µA až 100 µA CMC 0,15 % +0,06 µA 5 kHz až 10 kHz 10 µA až 100 µA CMC 0,35 % +0,7 µA 10 Hz až 5 kHz 100 µA až 1 mA CMC 0,1 % +0,4 µA 5 kHz až 10 kHz 100 µA až 1 mA CMC 0,2 % +2,5 µA 10 Hz až 5 kHz 1 mA až 10 mA CMC 0,15 % +6 µA 5 kHz až 10 kHz 1 mA až 10 mA CMC 0,35 % +70 µA 10 Hz až 5 kHz 10 mA až 100 mA CMC 0,1 % +40 µA 5 kHz až 10 kHz 10 mA až 100 mA CMC 0,2 % +0,25 mA 10 Hz až 5 kHz 100 mA až 400 mA CMC 0,1 % +0,1 mA 5 kHz až 10 kHz 100 mA až 400 mA CMC 0,2 % +0,7 mA 10 Hz až 5 kHz 400 mA až 1 A CMC 0,1 % +0,4 mA 5 kHz až 10 kHz 400 mA až 1 A CMC 0,35 % +7 mA 10 Hz až 5 kHz 1 A až 3 A CMC 0,15 % +1,8 mA 5 kHz až 10 kHz 1 A až 3 A CMC 0,35 % +21 mA 10 Hz až 5 kHz 3 A až 10 A CMC 0,15 % +6 mA 5 kHz až 10 kHz 3 A až 10 A CMC 0,35 % +70 mA VKP02/05 Prad przemienny / zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 10 Hz do 5 kHz od 10 µA do 100 µA CMC 0,15 % +0,06 µA 5 kHz do 10 kHz od 10 µA do 100 µA CMC 0,35 % +0,7 µA 10 Hz do 5 kHz od 100 µA do 1 mA CMC 0,1 % +0,4 µA 5 kHz do 10 kHz od 100 µA do 1 mA CMC 0,2 % +2,5 µA 10 Hz do 5 kHz od 1 mA do 10 mA CMC 0,15 % +6 µA 5 kHz do 10 kHz od 1 mA do 10 mA CMC 0,35 % +70 µA 10 Hz do 5 kHz od 10 mA do 100 mA CMC 0,1 % +40 µA 5 kHz do 10 kHz od 10 mA do 100 mA CMC 0,2 % +0,25 mA 10 Hz do 5 kHz od 100 mA do 400 mA CMC 0,1 % +0,1 mA 5 kHz do 10 kHz od 100 mA do 400 mA CMC 0,2 % +0,7 mA 10 Hz do 5 kHz od 400 mA do 1 A CMC 0,1 % +0,4 mA 5 kHz do 10 kHz od 400 mA do 1 A CMC 0,35 % +7 mA 10 Hz do 5 kHz od 1 A do 3 A CMC 0,15 % +1,8 mA 5 kHz do 10 kHz od 1 A do 3 A CMC 0,35 % +21 mA 10 Hz do 5 kHz od 3 A do 10 A CMC 0,15 % +6 mA 5 kHz do 10 kHz od 3 A do 10 A CMC 0,35 % +70 mA Stridavy proud / zdroje stridaveho proudu Kalibrace – elektricke veliciny Prime mereni multimetrem 10 Hz az 5 kHz 10 µA az 100 µA CMC 0,15 % +0,06 µA 5 kHz az 10 kHz 10 µA az 100 µA CMC 0,35 % +0,7 µA 10 Hz az 5 kHz 100 µA az 1 mA CMC 0,1 % +0,4 µA 5 kHz az 10 kHz 100 µA az 1 mA CMC 0,2 % +2,5 µA 10 Hz az 5 kHz 1 mA az 10 mA CMC 0,15 % +6 µA 5 kHz az 10 kHz 1 mA az 10 mA CMC 0,35 % +70 µA 10 Hz az 5 kHz 10 mA az 100 mA CMC 0,1 % +40 µA 5 kHz az 10 kHz 10 mA az 100 mA CMC 0,2 % +0,25 mA 10 Hz az 5 kHz 100 mA az 400 mA CMC 0,1 % +0,1 mA 5 kHz az 10 kHz 100 mA az 400 mA CMC 0,2 % +0,7 mA 10 Hz az 5 kHz 400 mA az 1 A CMC 0,1 % +0,4 mA 5 kHz az 10 kHz 400 mA az 1 A CMC 0,35 % +7 mA 10 Hz az 5 kHz 1 A az 3 A CMC 0,15 % +1,8 mA 5 kHz az 10 kHz 1 A az 3 A CMC 0,35 % +21 mA 10 Hz az 5 kHz 3 A az 10 A CMC 0,15 % +6 mA 5 kHz az 10 kHz 3 A az 10 A CMC 0,35 % +70 mA VKP02/05","search_en":"AC current / AC current sources Calibration – electrical quantities Direct measurement by a multimeter 10 Hz to 5 kHz 10 µA to 100 µA CMC 0,15 % +0,06 µA 5 kHz to 10 kHz 10 µA to 100 µA CMC 0,35 % +0,7 µA 10 Hz to 5 kHz 100 µA to 1 mA CMC 0,1 % +0,4 µA 5 kHz to 10 kHz 100 µA to 1 mA CMC 0,2 % +2,5 µA 10 Hz to 5 kHz 1 mA to 10 mA CMC 0,15 % +6 µA 5 kHz to 10 kHz 1 mA to 10 mA CMC 0,35 % +70 µA 10 Hz to 5 kHz 10 mA to 100 mA CMC 0,1 % +40 µA 5 kHz to 10 kHz 10 mA to 100 mA CMC 0,2 % +0,25 mA 10 Hz to 5 kHz 100 mA to 400 mA CMC 0,1 % +0,1 mA 5 kHz to 10 kHz 100 mA to 400 mA CMC 0,2 % +0,7 mA 10 Hz to 5 kHz 400 mA to 1 A CMC 0,1 % +0,4 mA 5 kHz to 10 kHz 400 mA to 1 A CMC 0,35 % +7 mA 10 Hz to 5 kHz 1 A to 3 A CMC 0,15 % +1,8 mA 5 kHz to 10 kHz 1 A to 3 A CMC 0,35 % +21 mA 10 Hz to 5 kHz 3 A to 10 A CMC 0,15 % +6 mA 5 kHz to 10 kHz 3 A to 10 A CMC 0,35 % +70 mA VKP02/05","search_zh":"交流电流 / 交流电流源 校准 – 电学量 用万用表直接测量 10 Hz 至 5 kHz 10 µA 至 100 µA CMC 0,15 % +0,06 µA 5 kHz 至 10 kHz 10 µA 至 100 µA CMC 0,35 % +0,7 µA 10 Hz 至 5 kHz 100 µA 至 1 mA CMC 0,1 % +0,4 µA 5 kHz 至 10 kHz 100 µA 至 1 mA CMC 0,2 % +2,5 µA 10 Hz 至 5 kHz 1 mA 至 10 mA CMC 0,15 % +6 µA 5 kHz 至 10 kHz 1 mA 至 10 mA CMC 0,35 % +70 µA 10 Hz 至 5 kHz 10 mA 至 100 mA CMC 0,1 % +40 µA 5 kHz 至 10 kHz 10 mA 至 100 mA CMC 0,2 % +0,25 mA 10 Hz 至 5 kHz 100 mA 至 400 mA CMC 0,1 % +0,1 mA 5 kHz 至 10 kHz 100 mA 至 400 mA CMC 0,2 % +0,7 mA 10 Hz 至 5 kHz 400 mA 至 1 A CMC 0,1 % +0,4 mA 5 kHz 至 10 kHz 400 mA 至 1 A CMC 0,35 % +7 mA 10 Hz 至 5 kHz 1 A 至 3 A CMC 0,15 % +1,8 mA 5 kHz 至 10 kHz 1 A 至 3 A CMC 0,35 % +21 mA 10 Hz 至 5 kHz 3 A 至 10 A CMC 0,15 % +6 mA 5 kHz 至 10 kHz 3 A 至 10 A CMC 0,35 % +70 mA VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e78e61c30a9061bae52e7447","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / źródła prądu przemiennego","test_object_en":"AC current / AC current sources","test_object_zh":"交流电流 / 交流电流源","test_object_cs":"Střídavý proud / zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 400 Hz","range":"od 10 A do 30 A","cmc":"0,3 % +15 mA"}],"parameters_en":[{"name":"20 Hz to 400 Hz","range":"10 A to 30 A","cmc":"0,3 % +15 mA"}],"parameters_zh":[{"name":"20 Hz 至 400 Hz","range":"10 A 至 30 A","cmc":"0,3 % +15 mA"}],"parameters_cs":[{"name":"20 Hz až 400 Hz","range":"10 A až 30 A","cmc":"0,3 % +15 mA"}],"technique":"Pomiar bezpośredni kalibratorem mierników do badań instalacji","technique_en":"Direct measurement by an installation tester calibrator","technique_zh":"用电气安装测试仪校准器直接测量","technique_cs":"Přímé měření kalibrátorem revizních přístrojů","techniques":["Pomiar bezpośredni kalibratorem mierników do badań instalacji"],"techniques_en":["Direct measurement by an installation tester calibrator"],"techniques_zh":["用电气安装测试仪校准器直接测量"],"techniques_cs":["Přímé měření kalibrátorem revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n20 Hz do 400 Hz od 10 A do 30 A CMC 0,3 % +15 mA\nPomiar bezpośredni kalibratorem mierników do badań instalacji","reference":"VKP02/05","norm_bases":["VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratorem mierników do badań instalacji 20 Hz do 400 Hz od 10 A do 30 A CMC 0,3 % +15 mA Střídavý proud / zdroje střídavého proudu Kalibrace – elektrické veličiny Přímé měření kalibrátorem revizních přístrojů 20 Hz až 400 Hz 10 A až 30 A CMC 0,3 % +15 mA VKP02/05 Prad przemienny / zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratorem miernikow do badan instalacji 20 Hz do 400 Hz od 10 A do 30 A CMC 0,3 % +15 mA Stridavy proud / zdroje stridaveho proudu Kalibrace – elektricke veliciny Prime mereni kalibratorem reviznich pristroju 20 Hz az 400 Hz 10 A az 30 A CMC 0,3 % +15 mA VKP02/05","search_en":"AC current / AC current sources Calibration – electrical quantities Direct measurement by an installation tester calibrator 20 Hz to 400 Hz 10 A to 30 A CMC 0,3 % +15 mA VKP02/05","search_zh":"交流电流 / 交流电流源 校准 – 电学量 用电气安装测试仪校准器直接测量 20 Hz 至 400 Hz 10 A 至 30 A CMC 0,3 % +15 mA VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9f6ca9724897730f1390fb27","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / mierniki rezystancji, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi","test_object_en":"DC resistance / DC resistance meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers","test_object_zh":"直流电阻 / 直流电阻表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪","test_object_cs":"Stejnosměrný odpor / měřidla stejnosměrného odporu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 12 Ω","cmc":"19 µΩ/Ω +1 mΩ"},{"name":"","range":"od 12 Ω do 120 Ω","cmc":"19 µΩ/Ω +1 mΩ"},{"name":"","range":"od 120 Ω do 1.2 kΩ","cmc":"19 µΩ/Ω +2 mΩ"},{"name":"","range":"od 1,2 kΩ do 12 kΩ","cmc":"19 µΩ/Ω +20 mΩ"},{"name":"","range":"od 12 kΩ do 120 kΩ","cmc":"19 µΩ/Ω +200 mΩ"},{"name":"","range":"od 120 kΩ do 1,2 MΩ","cmc":"19 µΩ/Ω +2 Ω"},{"name":"","range":"od 1,2 MΩ do 12 MΩ","cmc":"27 µΩ/Ω +30 Ω"},{"name":"","range":"od 12 MΩ do 120 MΩ","cmc":"330 µΩ/Ω +2,5 kΩ"},{"name":"","range":"od 120 MΩ do 1200 MΩ","cmc":"3 100 µΩ/Ω +100 kΩ"}],"parameters_en":[{"name":"","range":"0 Ω to 12 Ω","cmc":"19 µΩ/Ω +1 mΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"19 µΩ/Ω +1 mΩ"},{"name":"","range":"120 Ω to 1.2 kΩ","cmc":"19 µΩ/Ω +2 mΩ"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"19 µΩ/Ω +20 mΩ"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"19 µΩ/Ω +200 mΩ"},{"name":"","range":"120 kΩ to 1,2 MΩ","cmc":"19 µΩ/Ω +2 Ω"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"27 µΩ/Ω +30 Ω"},{"name":"","range":"12 MΩ to 120 MΩ","cmc":"330 µΩ/Ω +2,5 kΩ"},{"name":"","range":"120 MΩ to 1200 MΩ","cmc":"3 100 µΩ/Ω +100 kΩ"}],"parameters_zh":[{"name":"","range":"0 Ω 至 12 Ω","cmc":"19 µΩ/Ω +1 mΩ"},{"name":"","range":"12 Ω 至 120 Ω","cmc":"19 µΩ/Ω +1 mΩ"},{"name":"","range":"120 Ω 至 1.2 kΩ","cmc":"19 µΩ/Ω +2 mΩ"},{"name":"","range":"1,2 kΩ 至 12 kΩ","cmc":"19 µΩ/Ω +20 mΩ"},{"name":"","range":"12 kΩ 至 120 kΩ","cmc":"19 µΩ/Ω +200 mΩ"},{"name":"","range":"120 kΩ 至 1,2 MΩ","cmc":"19 µΩ/Ω +2 Ω"},{"name":"","range":"1,2 MΩ 至 12 MΩ","cmc":"27 µΩ/Ω +30 Ω"},{"name":"","range":"12 MΩ 至 120 MΩ","cmc":"330 µΩ/Ω +2,5 kΩ"},{"name":"","range":"120 MΩ 至 1200 MΩ","cmc":"3 100 µΩ/Ω +100 kΩ"}],"parameters_cs":[{"name":"","range":"0 Ω až 12 Ω","cmc":"19 µΩ/Ω +1 mΩ"},{"name":"","range":"12 Ω až 120 Ω","cmc":"19 µΩ/Ω +1 mΩ"},{"name":"","range":"120 Ω až 1.2 kΩ","cmc":"19 µΩ/Ω +2 mΩ"},{"name":"","range":"1,2 kΩ až 12 kΩ","cmc":"19 µΩ/Ω +20 mΩ"},{"name":"","range":"12 kΩ až 120 kΩ","cmc":"19 µΩ/Ω +200 mΩ"},{"name":"","range":"120 kΩ až 1,2 MΩ","cmc":"19 µΩ/Ω +2 Ω"},{"name":"","range":"1,2 MΩ až 12 MΩ","cmc":"27 µΩ/Ω +30 Ω"},{"name":"","range":"12 MΩ až 120 MΩ","cmc":"330 µΩ/Ω +2,5 kΩ"},{"name":"","range":"120 MΩ až 1200 MΩ","cmc":"3 100 µΩ/Ω +100 kΩ"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation by a standard calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation by a standard calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 12 Ω CMC 19 µΩ/Ω +1 mΩ\nod 12 Ω do 120 Ω CMC 19 µΩ/Ω +1 mΩ\nod 120 Ω do 1.2 kΩ CMC 19 µΩ/Ω +2 mΩ\nod 1,2 kΩ do 12 kΩ CMC 19 µΩ/Ω +20 mΩ\nod 12 kΩ do 120 kΩ CMC 19 µΩ/Ω +200 mΩ\nod 120 kΩ do 1,2 MΩ CMC 19 µΩ/Ω +2 Ω\nod 1,2 MΩ do 12 MΩ CMC 27 µΩ/Ω +30 Ω\nod 12 MΩ do 120 MΩ CMC 330 µΩ/Ω +2,5 kΩ\nod 120 MΩ do 1200 MΩ CMC 3 100 µΩ/Ω +100 kΩ\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / mierniki rezystancji, kalibratory, multimetry, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień, testery elektronarzędzi Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym od 0 Ω do 12 Ω CMC 19 µΩ/Ω +1 mΩ od 12 Ω do 120 Ω CMC 19 µΩ/Ω +1 mΩ od 120 Ω do 1.2 kΩ CMC 19 µΩ/Ω +2 mΩ od 1,2 kΩ do 12 kΩ CMC 19 µΩ/Ω +20 mΩ od 12 kΩ do 120 kΩ CMC 19 µΩ/Ω +200 mΩ od 120 kΩ do 1,2 MΩ CMC 19 µΩ/Ω +2 Ω od 1,2 MΩ do 12 MΩ CMC 27 µΩ/Ω +30 Ω od 12 MΩ do 120 MΩ CMC 330 µΩ/Ω +2,5 kΩ od 120 MΩ do 1200 MΩ CMC 3 100 µΩ/Ω +100 kΩ Stejnosměrný odpor / měřidla stejnosměrného odporu, kalibrátory, multimetry, klešťová měřidla, revizní měřidla, multifunkční testery, měřiče zemního odporu, měřidla uzemnění, testery ručního nářadí Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 0 Ω až 12 Ω CMC 19 µΩ/Ω +1 mΩ 12 Ω až 120 Ω CMC 19 µΩ/Ω +1 mΩ 120 Ω až 1.2 kΩ CMC 19 µΩ/Ω +2 mΩ 1,2 kΩ až 12 kΩ CMC 19 µΩ/Ω +20 mΩ 12 kΩ až 120 kΩ CMC 19 µΩ/Ω +200 mΩ 120 kΩ až 1,2 MΩ CMC 19 µΩ/Ω +2 Ω 1,2 MΩ až 12 MΩ CMC 27 µΩ/Ω +30 Ω 12 MΩ až 120 MΩ CMC 330 µΩ/Ω +2,5 kΩ 120 MΩ až 1200 MΩ CMC 3 100 µΩ/Ω +100 kΩ VKP01/05 VKP02/05 Rezystancja przy pradzie stalym / mierniki rezystancji, kalibratory, multimetry, mierniki cegowe, mierniki do badan instalacji, testery wielofunkcyjne, mierniki rezystancji uziemien, mierniki uziemien, testery elektronarzedzi Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym od 0 Ω do 12 Ω CMC 19 µΩ/Ω +1 mΩ od 12 Ω do 120 Ω CMC 19 µΩ/Ω +1 mΩ od 120 Ω do 1.2 kΩ CMC 19 µΩ/Ω +2 mΩ od 1,2 kΩ do 12 kΩ CMC 19 µΩ/Ω +20 mΩ od 12 kΩ do 120 kΩ CMC 19 µΩ/Ω +200 mΩ od 120 kΩ do 1,2 MΩ CMC 19 µΩ/Ω +2 Ω od 1,2 MΩ do 12 MΩ CMC 27 µΩ/Ω +30 Ω od 12 MΩ do 120 MΩ CMC 330 µΩ/Ω +2,5 kΩ od 120 MΩ do 1200 MΩ CMC 3 100 µΩ/Ω +100 kΩ Stejnosmerny odpor / meridla stejnosmerneho odporu, kalibratory, multimetry, klestova meridla, revizni meridla, multifunkcni testery, merice zemniho odporu, meridla uzemneni, testery rucniho naradi Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 0 Ω az 12 Ω CMC 19 µΩ/Ω +1 mΩ 12 Ω az 120 Ω CMC 19 µΩ/Ω +1 mΩ 120 Ω az 1.2 kΩ CMC 19 µΩ/Ω +2 mΩ 1,2 kΩ az 12 kΩ CMC 19 µΩ/Ω +20 mΩ 12 kΩ az 120 kΩ CMC 19 µΩ/Ω +200 mΩ 120 kΩ az 1,2 MΩ CMC 19 µΩ/Ω +2 Ω 1,2 MΩ az 12 MΩ CMC 27 µΩ/Ω +30 Ω 12 MΩ az 120 MΩ CMC 330 µΩ/Ω +2,5 kΩ 120 MΩ az 1200 MΩ CMC 3 100 µΩ/Ω +100 kΩ VKP01/05 VKP02/05","search_en":"DC resistance / DC resistance meters, calibrators, multimeters, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters, hand tool testers Calibration – electrical quantities Direct generation by a standard calibrator 0 Ω to 12 Ω CMC 19 µΩ/Ω +1 mΩ 12 Ω to 120 Ω CMC 19 µΩ/Ω +1 mΩ 120 Ω to 1.2 kΩ CMC 19 µΩ/Ω +2 mΩ 1,2 kΩ to 12 kΩ CMC 19 µΩ/Ω +20 mΩ 12 kΩ to 120 kΩ CMC 19 µΩ/Ω +200 mΩ 120 kΩ to 1,2 MΩ CMC 19 µΩ/Ω +2 Ω 1,2 MΩ to 12 MΩ CMC 27 µΩ/Ω +30 Ω 12 MΩ to 120 MΩ CMC 330 µΩ/Ω +2,5 kΩ 120 MΩ to 1200 MΩ CMC 3 100 µΩ/Ω +100 kΩ VKP01/05 VKP02/05","search_zh":"直流电阻 / 直流电阻表、校准器、万用表、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪、手持工具测试仪 校准 – 电学量 用标准校准器直接产生 0 Ω 至 12 Ω CMC 19 µΩ/Ω +1 mΩ 12 Ω 至 120 Ω CMC 19 µΩ/Ω +1 mΩ 120 Ω 至 1.2 kΩ CMC 19 µΩ/Ω +2 mΩ 1,2 kΩ 至 12 kΩ CMC 19 µΩ/Ω +20 mΩ 12 kΩ 至 120 kΩ CMC 19 µΩ/Ω +200 mΩ 120 kΩ 至 1,2 MΩ CMC 19 µΩ/Ω +2 Ω 1,2 MΩ 至 12 MΩ CMC 27 µΩ/Ω +30 Ω 12 MΩ 至 120 MΩ CMC 330 µΩ/Ω +2,5 kΩ 120 MΩ 至 1200 MΩ CMC 3 100 µΩ/Ω +100 kΩ VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6447c8cc5ceed03fa50878df","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / dekady rezystancyjne, wzorce rezystancji, boczniki, kalibratory","test_object_en":"DC resistance / resistance decades, resistance standards, shunts, calibrators","test_object_zh":"直流电阻 / 电阻箱、电阻标准、分流器、校准器","test_object_cs":"Stejnosměrný odpor / odporové dekády, etalony odporu, odporové bočníky, kalibrátory","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 10 Ω","cmc":"0,008 % +3 mΩ"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"0,008 % +4 mΩ"},{"name":"","range":"od 100 Ω do 1000 Ω","cmc":"0,008 % +0,01 Ω"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,008 % +0,1 Ω"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"0,008 % +1 Ω"},{"name":"","range":"od 100 kΩ do 1 MΩ","cmc":"0,008 % +10 Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,02 % +0,1 kΩ"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,8 % +10 kΩ"},{"name":"","range":"od 100 MΩ do 1 GΩ","cmc":"1,5 % +0,1 MΩ"}],"parameters_en":[{"name":"","range":"0 Ω to 10 Ω","cmc":"0,008 % +3 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,008 % +4 mΩ"},{"name":"","range":"100 Ω to 1000 Ω","cmc":"0,008 % +0,01 Ω"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,008 % +0,1 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,008 % +1 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,008 % +10 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,02 % +0,1 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,8 % +10 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"1,5 % +0,1 MΩ"}],"parameters_zh":[{"name":"","range":"0 Ω 至 10 Ω","cmc":"0,008 % +3 mΩ"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"0,008 % +4 mΩ"},{"name":"","range":"100 Ω 至 1000 Ω","cmc":"0,008 % +0,01 Ω"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,008 % +0,1 Ω"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"0,008 % +1 Ω"},{"name":"","range":"100 kΩ 至 1 MΩ","cmc":"0,008 % +10 Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,02 % +0,1 kΩ"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,8 % +10 kΩ"},{"name":"","range":"100 MΩ 至 1 GΩ","cmc":"1,5 % +0,1 MΩ"}],"parameters_cs":[{"name":"","range":"0 Ω až 10 Ω","cmc":"0,008 % +3 mΩ"},{"name":"","range":"10 Ω až 100 Ω","cmc":"0,008 % +4 mΩ"},{"name":"","range":"100 Ω až 1000 Ω","cmc":"0,008 % +0,01 Ω"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,008 % +0,1 Ω"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"0,008 % +1 Ω"},{"name":"","range":"100 kΩ až 1 MΩ","cmc":"0,008 % +10 Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,02 % +0,1 kΩ"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,8 % +10 kΩ"},{"name":"","range":"100 MΩ až 1 GΩ","cmc":"1,5 % +0,1 MΩ"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement by a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement by a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 10 Ω CMC 0,008 % +3 mΩ\nod 10 Ω do 100 Ω CMC 0,008 % +4 mΩ\nod 100 Ω do 1000 Ω CMC 0,008 % +0,01 Ω\nod 1 kΩ do 10 kΩ CMC 0,008 % +0,1 Ω\nod 10 kΩ do 100 kΩ CMC 0,008 % +1 Ω\nod 100 kΩ do 1 MΩ CMC 0,008 % +10 Ω\nod 1 MΩ do 10 MΩ CMC 0,02 % +0,1 kΩ\nod 10 MΩ do 100 MΩ CMC 0,8 % +10 kΩ\nod 100 MΩ do 1 GΩ CMC 1,5 % +0,1 MΩ\nPomiar bezpośredni multimetrem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / dekady rezystancyjne, wzorce rezystancji, boczniki, kalibratory Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 Ω do 10 Ω CMC 0,008 % +3 mΩ od 10 Ω do 100 Ω CMC 0,008 % +4 mΩ od 100 Ω do 1000 Ω CMC 0,008 % +0,01 Ω od 1 kΩ do 10 kΩ CMC 0,008 % +0,1 Ω od 10 kΩ do 100 kΩ CMC 0,008 % +1 Ω od 100 kΩ do 1 MΩ CMC 0,008 % +10 Ω od 1 MΩ do 10 MΩ CMC 0,02 % +0,1 kΩ od 10 MΩ do 100 MΩ CMC 0,8 % +10 kΩ od 100 MΩ do 1 GΩ CMC 1,5 % +0,1 MΩ Stejnosměrný odpor / odporové dekády, etalony odporu, odporové bočníky, kalibrátory Kalibrace – elektrické veličiny Přímé měření multimetrem 0 Ω až 10 Ω CMC 0,008 % +3 mΩ 10 Ω až 100 Ω CMC 0,008 % +4 mΩ 100 Ω až 1000 Ω CMC 0,008 % +0,01 Ω 1 kΩ až 10 kΩ CMC 0,008 % +0,1 Ω 10 kΩ až 100 kΩ CMC 0,008 % +1 Ω 100 kΩ až 1 MΩ CMC 0,008 % +10 Ω 1 MΩ až 10 MΩ CMC 0,02 % +0,1 kΩ 10 MΩ až 100 MΩ CMC 0,8 % +10 kΩ 100 MΩ až 1 GΩ CMC 1,5 % +0,1 MΩ VKP01/05 VKP02/05 Rezystancja przy pradzie stalym / dekady rezystancyjne, wzorce rezystancji, boczniki, kalibratory Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 Ω do 10 Ω CMC 0,008 % +3 mΩ od 10 Ω do 100 Ω CMC 0,008 % +4 mΩ od 100 Ω do 1000 Ω CMC 0,008 % +0,01 Ω od 1 kΩ do 10 kΩ CMC 0,008 % +0,1 Ω od 10 kΩ do 100 kΩ CMC 0,008 % +1 Ω od 100 kΩ do 1 MΩ CMC 0,008 % +10 Ω od 1 MΩ do 10 MΩ CMC 0,02 % +0,1 kΩ od 10 MΩ do 100 MΩ CMC 0,8 % +10 kΩ od 100 MΩ do 1 GΩ CMC 1,5 % +0,1 MΩ Stejnosmerny odpor / odporove dekady, etalony odporu, odporove bocniky, kalibratory Kalibrace – elektricke veliciny Prime mereni multimetrem 0 Ω az 10 Ω CMC 0,008 % +3 mΩ 10 Ω az 100 Ω CMC 0,008 % +4 mΩ 100 Ω az 1000 Ω CMC 0,008 % +0,01 Ω 1 kΩ az 10 kΩ CMC 0,008 % +0,1 Ω 10 kΩ az 100 kΩ CMC 0,008 % +1 Ω 100 kΩ az 1 MΩ CMC 0,008 % +10 Ω 1 MΩ az 10 MΩ CMC 0,02 % +0,1 kΩ 10 MΩ az 100 MΩ CMC 0,8 % +10 kΩ 100 MΩ az 1 GΩ CMC 1,5 % +0,1 MΩ VKP01/05 VKP02/05","search_en":"DC resistance / resistance decades, resistance standards, shunts, calibrators Calibration – electrical quantities Direct measurement by a multimeter 0 Ω to 10 Ω CMC 0,008 % +3 mΩ 10 Ω to 100 Ω CMC 0,008 % +4 mΩ 100 Ω to 1000 Ω CMC 0,008 % +0,01 Ω 1 kΩ to 10 kΩ CMC 0,008 % +0,1 Ω 10 kΩ to 100 kΩ CMC 0,008 % +1 Ω 100 kΩ to 1 MΩ CMC 0,008 % +10 Ω 1 MΩ to 10 MΩ CMC 0,02 % +0,1 kΩ 10 MΩ to 100 MΩ CMC 0,8 % +10 kΩ 100 MΩ to 1 GΩ CMC 1,5 % +0,1 MΩ VKP01/05 VKP02/05","search_zh":"直流电阻 / 电阻箱、电阻标准、分流器、校准器 校准 – 电学量 用万用表直接测量 0 Ω 至 10 Ω CMC 0,008 % +3 mΩ 10 Ω 至 100 Ω CMC 0,008 % +4 mΩ 100 Ω 至 1000 Ω CMC 0,008 % +0,01 Ω 1 kΩ 至 10 kΩ CMC 0,008 % +0,1 Ω 10 kΩ 至 100 kΩ CMC 0,008 % +1 Ω 100 kΩ 至 1 MΩ CMC 0,008 % +10 Ω 1 MΩ 至 10 MΩ CMC 0,02 % +0,1 kΩ 10 MΩ 至 100 MΩ CMC 0,8 % +10 kΩ 100 MΩ 至 1 GΩ CMC 1,5 % +0,1 MΩ VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d7c4c8a5d73591682ec306e6","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja izolacji / mierniki do badań instalacji, testery wielofunkcyjne, testery elektronarzędzi, mierniki izolacji i rezystancji przejścia","test_object_en":"Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters","test_object_zh":"绝缘电阻 / 电气安装测试仪、多功能测试仪、手持工具测试仪、绝缘和接触电阻测试仪","test_object_cs":"Izolační odpor / revizní měřidla, multifunkční testery, testery ručního nářadí, měřidla izolace a přechodových odporů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"max. 55 V DC","range":"od 10 kΩ do 40 kΩ","cmc":"0,2 %"},{"name":"max. 300 V DC","range":"od 40 kΩ do 100 kΩ","cmc":"0,2 %"},{"name":"max. 800 V DC","range":"od 100 kΩ do 200 kΩ","cmc":"0,2 %"},{"name":"max. 1 100 V DC","range":"od 200 kΩ do 1 MΩ","cmc":"0,2 %"},{"name":"max. 1 100 V DC","range":"od 1 MΩ do 10 MΩ","cmc":"0,3 %"},{"name":"max. 1 575 V DC","range":"od 10 MΩ do 100 MΩ","cmc":"0,5 %"},{"name":"max. 1 575 V DC","range":"od 100 MΩ do 1 GΩ","cmc":"1 %"},{"name":"max. 1 575 V DC","range":"od 1 GΩ do 10 GΩ","cmc":"3 %"},{"name":"max. 1 575 V DC","range":"89,24 GΩ","cmc":"5 %"}],"parameters_en":[{"name":"max. 55 V DC","range":"10 kΩ to 40 kΩ","cmc":"0,2 %"},{"name":"max. 300 V DC","range":"40 kΩ to 100 kΩ","cmc":"0,2 %"},{"name":"max. 800 V DC","range":"100 kΩ to 200 kΩ","cmc":"0,2 %"},{"name":"max. 1 100 V DC","range":"200 kΩ to 1 MΩ","cmc":"0,2 %"},{"name":"max. 1 100 V DC","range":"1 MΩ to 10 MΩ","cmc":"0,3 %"},{"name":"max. 1 575 V DC","range":"10 MΩ to 100 MΩ","cmc":"0,5 %"},{"name":"max. 1 575 V DC","range":"100 MΩ to 1 GΩ","cmc":"1 %"},{"name":"max. 1 575 V DC","range":"1 GΩ to 10 GΩ","cmc":"3 %"},{"name":"max. 1 575 V DC","range":"89,24 GΩ","cmc":"5 %"}],"parameters_zh":[{"name":"max. 55 V DC","range":"10 kΩ 至 40 kΩ","cmc":"0,2 %"},{"name":"max. 300 V DC","range":"40 kΩ 至 100 kΩ","cmc":"0,2 %"},{"name":"max. 800 V DC","range":"100 kΩ 至 200 kΩ","cmc":"0,2 %"},{"name":"max. 1 100 V DC","range":"200 kΩ 至 1 MΩ","cmc":"0,2 %"},{"name":"max. 1 100 V DC","range":"1 MΩ 至 10 MΩ","cmc":"0,3 %"},{"name":"max. 1 575 V DC","range":"10 MΩ 至 100 MΩ","cmc":"0,5 %"},{"name":"max. 1 575 V DC","range":"100 MΩ 至 1 GΩ","cmc":"1 %"},{"name":"max. 1 575 V DC","range":"1 GΩ 至 10 GΩ","cmc":"3 %"},{"name":"max. 1 575 V DC","range":"89,24 GΩ","cmc":"5 %"}],"parameters_cs":[{"name":"max. 55 V DC","range":"10 kΩ až 40 kΩ","cmc":"0,2 %"},{"name":"max. 300 V DC","range":"40 kΩ až 100 kΩ","cmc":"0,2 %"},{"name":"max. 800 V DC","range":"100 kΩ až 200 kΩ","cmc":"0,2 %"},{"name":"max. 1 100 V DC","range":"200 kΩ až 1 MΩ","cmc":"0,2 %"},{"name":"max. 1 100 V DC","range":"1 MΩ až 10 MΩ","cmc":"0,3 %"},{"name":"max. 1 575 V DC","range":"10 MΩ až 100 MΩ","cmc":"0,5 %"},{"name":"max. 1 575 V DC","range":"100 MΩ až 1 GΩ","cmc":"1 %"},{"name":"max. 1 575 V DC","range":"1 GΩ až 10 GΩ","cmc":"3 %"},{"name":"max. 1 575 V DC","range":"89,24 GΩ","cmc":"5 %"}],"technique":"Bezpośrednie generowanie kalibratorem mierników do badań instalacji","technique_en":"Direct generation by an installation tester calibrator","technique_zh":"用电气安装测试仪校准器直接产生","technique_cs":"Přímé generování kalibrátorem revizních přístrojů","techniques":["Bezpośrednie generowanie kalibratorem mierników do badań instalacji"],"techniques_en":["Direct generation by an installation tester calibrator"],"techniques_zh":["用电气安装测试仪校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nmax. 55 V DC od 10 kΩ do 40 kΩ CMC 0,2 %\nmax. 300 V DC od 40 kΩ do 100 kΩ CMC 0,2 %\nmax. 800 V DC od 100 kΩ do 200 kΩ CMC 0,2 %\nmax. 1 100 V DC od 200 kΩ do 1 MΩ CMC 0,2 %\nmax. 1 100 V DC od 1 MΩ do 10 MΩ CMC 0,3 %\nmax. 1 575 V DC od 10 MΩ do 100 MΩ CMC 0,5 %\nmax. 1 575 V DC od 100 MΩ do 1 GΩ CMC 1 %\nmax. 1 575 V DC od 1 GΩ do 10 GΩ CMC 3 %\nmax. 1 575 V DC 89,24 GΩ CMC 5 %\nBezpośrednie generowanie kalibratorem mierników do badań instalacji","reference":"VKP02/05","norm_bases":["VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja izolacji / mierniki do badań instalacji, testery wielofunkcyjne, testery elektronarzędzi, mierniki izolacji i rezystancji przejścia Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem mierników do badań instalacji max. 55 V DC od 10 kΩ do 40 kΩ CMC 0,2 % max. 300 V DC od 40 kΩ do 100 kΩ CMC 0,2 % max. 800 V DC od 100 kΩ do 200 kΩ CMC 0,2 % max. 1 100 V DC od 200 kΩ do 1 MΩ CMC 0,2 % max. 1 100 V DC od 1 MΩ do 10 MΩ CMC 0,3 % max. 1 575 V DC od 10 MΩ do 100 MΩ CMC 0,5 % max. 1 575 V DC od 100 MΩ do 1 GΩ CMC 1 % max. 1 575 V DC od 1 GΩ do 10 GΩ CMC 3 % max. 1 575 V DC 89,24 GΩ CMC 5 % Izolační odpor / revizní měřidla, multifunkční testery, testery ručního nářadí, měřidla izolace a přechodových odporů Kalibrace – elektrické veličiny Přímé generování kalibrátorem revizních přístrojů max. 55 V DC 10 kΩ až 40 kΩ CMC 0,2 % max. 300 V DC 40 kΩ až 100 kΩ CMC 0,2 % max. 800 V DC 100 kΩ až 200 kΩ CMC 0,2 % max. 1 100 V DC 200 kΩ až 1 MΩ CMC 0,2 % max. 1 100 V DC 1 MΩ až 10 MΩ CMC 0,3 % max. 1 575 V DC 10 MΩ až 100 MΩ CMC 0,5 % max. 1 575 V DC 100 MΩ až 1 GΩ CMC 1 % max. 1 575 V DC 1 GΩ až 10 GΩ CMC 3 % max. 1 575 V DC 89,24 GΩ CMC 5 % VKP02/05 Rezystancja izolacji / mierniki do badan instalacji, testery wielofunkcyjne, testery elektronarzedzi, mierniki izolacji i rezystancji przejscia Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem miernikow do badan instalacji max. 55 V DC od 10 kΩ do 40 kΩ CMC 0,2 % max. 300 V DC od 40 kΩ do 100 kΩ CMC 0,2 % max. 800 V DC od 100 kΩ do 200 kΩ CMC 0,2 % max. 1 100 V DC od 200 kΩ do 1 MΩ CMC 0,2 % max. 1 100 V DC od 1 MΩ do 10 MΩ CMC 0,3 % max. 1 575 V DC od 10 MΩ do 100 MΩ CMC 0,5 % max. 1 575 V DC od 100 MΩ do 1 GΩ CMC 1 % max. 1 575 V DC od 1 GΩ do 10 GΩ CMC 3 % max. 1 575 V DC 89,24 GΩ CMC 5 % Izolacni odpor / revizni meridla, multifunkcni testery, testery rucniho naradi, meridla izolace a prechodovych odporu Kalibrace – elektricke veliciny Prime generovani kalibratorem reviznich pristroju max. 55 V DC 10 kΩ az 40 kΩ CMC 0,2 % max. 300 V DC 40 kΩ az 100 kΩ CMC 0,2 % max. 800 V DC 100 kΩ az 200 kΩ CMC 0,2 % max. 1 100 V DC 200 kΩ az 1 MΩ CMC 0,2 % max. 1 100 V DC 1 MΩ az 10 MΩ CMC 0,3 % max. 1 575 V DC 10 MΩ az 100 MΩ CMC 0,5 % max. 1 575 V DC 100 MΩ az 1 GΩ CMC 1 % max. 1 575 V DC 1 GΩ az 10 GΩ CMC 3 % max. 1 575 V DC 89,24 GΩ CMC 5 % VKP02/05","search_en":"Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters Calibration – electrical quantities Direct generation by an installation tester calibrator max. 55 V DC 10 kΩ to 40 kΩ CMC 0,2 % max. 300 V DC 40 kΩ to 100 kΩ CMC 0,2 % max. 800 V DC 100 kΩ to 200 kΩ CMC 0,2 % max. 1 100 V DC 200 kΩ to 1 MΩ CMC 0,2 % max. 1 100 V DC 1 MΩ to 10 MΩ CMC 0,3 % max. 1 575 V DC 10 MΩ to 100 MΩ CMC 0,5 % max. 1 575 V DC 100 MΩ to 1 GΩ CMC 1 % max. 1 575 V DC 1 GΩ to 10 GΩ CMC 3 % max. 1 575 V DC 89,24 GΩ CMC 5 % VKP02/05","search_zh":"绝缘电阻 / 电气安装测试仪、多功能测试仪、手持工具测试仪、绝缘和接触电阻测试仪 校准 – 电学量 用电气安装测试仪校准器直接产生 max. 55 V DC 10 kΩ 至 40 kΩ CMC 0,2 % max. 300 V DC 40 kΩ 至 100 kΩ CMC 0,2 % max. 800 V DC 100 kΩ 至 200 kΩ CMC 0,2 % max. 1 100 V DC 200 kΩ 至 1 MΩ CMC 0,2 % max. 1 100 V DC 1 MΩ 至 10 MΩ CMC 0,3 % max. 1 575 V DC 10 MΩ 至 100 MΩ CMC 0,5 % max. 1 575 V DC 100 MΩ 至 1 GΩ CMC 1 % max. 1 575 V DC 1 GΩ 至 10 GΩ CMC 3 % max. 1 575 V DC 89,24 GΩ CMC 5 % VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"353783dafa5e63a4a74e465e","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja izolacji / mierniki do badań instalacji, testery wielofunkcyjne, testery elektronarzędzi, mierniki izolacji i rezystancji przejścia","test_object_en":"Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters","test_object_zh":"绝缘电阻 / 电气安装测试仪、多功能测试仪、手持工具测试仪、绝缘和接触电阻测试仪","test_object_cs":"Izolační odpor / revizní měřidla, multifunkční testery, testery ručního nářadí, měřidla izolace a přechodových odporů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"max. 10 kV DC","range":"od 350 MΩ do 1 GΩ","cmc":"3,2 %"},{"name":"max. 10 kV DC","range":"od 1 GΩ do 10 GΩ","cmc":"3,3 %"},{"name":"max. 10 kV DC","range":"od 10 GΩ do 100 GΩ","cmc":"3,5 %"},{"name":"max. 10 kV DC","range":"od 100 GΩ do 1 TΩ","cmc":"4 %"},{"name":"max. 10 kV DC","range":"od 1 TΩ do 10 TΩ","cmc":"6 %"}],"parameters_en":[{"name":"max. 10 kV DC","range":"350 MΩ to 1 GΩ","cmc":"3,2 %"},{"name":"max. 10 kV DC","range":"1 GΩ to 10 GΩ","cmc":"3,3 %"},{"name":"max. 10 kV DC","range":"10 GΩ to 100 GΩ","cmc":"3,5 %"},{"name":"max. 10 kV DC","range":"100 GΩ to 1 TΩ","cmc":"4 %"},{"name":"max. 10 kV DC","range":"1 TΩ to 10 TΩ","cmc":"6 %"}],"parameters_zh":[{"name":"max. 10 kV DC","range":"350 MΩ 至 1 GΩ","cmc":"3,2 %"},{"name":"max. 10 kV DC","range":"1 GΩ 至 10 GΩ","cmc":"3,3 %"},{"name":"max. 10 kV DC","range":"10 GΩ 至 100 GΩ","cmc":"3,5 %"},{"name":"max. 10 kV DC","range":"100 GΩ 至 1 TΩ","cmc":"4 %"},{"name":"max. 10 kV DC","range":"1 TΩ 至 10 TΩ","cmc":"6 %"}],"parameters_cs":[{"name":"max. 10 kV DC","range":"350 MΩ až 1 GΩ","cmc":"3,2 %"},{"name":"max. 10 kV DC","range":"1 GΩ až 10 GΩ","cmc":"3,3 %"},{"name":"max. 10 kV DC","range":"10 GΩ až 100 GΩ","cmc":"3,5 %"},{"name":"max. 10 kV DC","range":"100 GΩ až 1 TΩ","cmc":"4 %"},{"name":"max. 10 kV DC","range":"1 TΩ až 10 TΩ","cmc":"6 %"}],"technique":"Pośrednie generowanie wzorcowym kalibratorem mierników do badań instalacji z użyciem mnożnika rezystancji","technique_en":"Indirect generation by a standard installation tester calibrator using a resistance multiplier","technique_zh":"使用电阻倍增器由标准电气安装测试仪校准器间接产生","technique_cs":"Nepřímé generování etalonovým kalibrátorem revizních přístrojů použitím odporového násobiče","techniques":["Pośrednie generowanie wzorcowym kalibratorem mierników do badań instalacji z użyciem mnożnika rezystancji"],"techniques_en":["Indirect generation by a standard installation tester calibrator using a resistance multiplier"],"techniques_zh":["使用电阻倍增器由标准电气安装测试仪校准器间接产生"],"techniques_cs":["Nepřímé generování etalonovým kalibrátorem revizních přístrojů použitím odporového násobiče"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nmax. 10 kV DC od 350 MΩ do 1 GΩ CMC 3,2 %\nmax. 10 kV DC od 1 GΩ do 10 GΩ CMC 3,3 %\nmax. 10 kV DC od 10 GΩ do 100 GΩ CMC 3,5 %\nmax. 10 kV DC od 100 GΩ do 1 TΩ CMC 4 %\nmax. 10 kV DC od 1 TΩ do 10 TΩ CMC 6 %\nPośrednie generowanie wzorcowym kalibratorem mierników do badań instalacji z użyciem mnożnika rezystancji","reference":"VKP02/05","norm_bases":["VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja izolacji / mierniki do badań instalacji, testery wielofunkcyjne, testery elektronarzędzi, mierniki izolacji i rezystancji przejścia Wzorcowanie – wielkości elektryczne Pośrednie generowanie wzorcowym kalibratorem mierników do badań instalacji z użyciem mnożnika rezystancji max. 10 kV DC od 350 MΩ do 1 GΩ CMC 3,2 % max. 10 kV DC od 1 GΩ do 10 GΩ CMC 3,3 % max. 10 kV DC od 10 GΩ do 100 GΩ CMC 3,5 % max. 10 kV DC od 100 GΩ do 1 TΩ CMC 4 % max. 10 kV DC od 1 TΩ do 10 TΩ CMC 6 % Izolační odpor / revizní měřidla, multifunkční testery, testery ručního nářadí, měřidla izolace a přechodových odporů Kalibrace – elektrické veličiny Nepřímé generování etalonovým kalibrátorem revizních přístrojů použitím odporového násobiče max. 10 kV DC 350 MΩ až 1 GΩ CMC 3,2 % max. 10 kV DC 1 GΩ až 10 GΩ CMC 3,3 % max. 10 kV DC 10 GΩ až 100 GΩ CMC 3,5 % max. 10 kV DC 100 GΩ až 1 TΩ CMC 4 % max. 10 kV DC 1 TΩ až 10 TΩ CMC 6 % VKP02/05 Rezystancja izolacji / mierniki do badan instalacji, testery wielofunkcyjne, testery elektronarzedzi, mierniki izolacji i rezystancji przejscia Wzorcowanie – wielkosci elektryczne Posrednie generowanie wzorcowym kalibratorem miernikow do badan instalacji z uzyciem mnoznika rezystancji max. 10 kV DC od 350 MΩ do 1 GΩ CMC 3,2 % max. 10 kV DC od 1 GΩ do 10 GΩ CMC 3,3 % max. 10 kV DC od 10 GΩ do 100 GΩ CMC 3,5 % max. 10 kV DC od 100 GΩ do 1 TΩ CMC 4 % max. 10 kV DC od 1 TΩ do 10 TΩ CMC 6 % Izolacni odpor / revizni meridla, multifunkcni testery, testery rucniho naradi, meridla izolace a prechodovych odporu Kalibrace – elektricke veliciny Neprime generovani etalonovym kalibratorem reviznich pristroju pouzitim odporoveho nasobice max. 10 kV DC 350 MΩ az 1 GΩ CMC 3,2 % max. 10 kV DC 1 GΩ az 10 GΩ CMC 3,3 % max. 10 kV DC 10 GΩ az 100 GΩ CMC 3,5 % max. 10 kV DC 100 GΩ az 1 TΩ CMC 4 % max. 10 kV DC 1 TΩ az 10 TΩ CMC 6 % VKP02/05","search_en":"Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters Calibration – electrical quantities Indirect generation by a standard installation tester calibrator using a resistance multiplier max. 10 kV DC 350 MΩ to 1 GΩ CMC 3,2 % max. 10 kV DC 1 GΩ to 10 GΩ CMC 3,3 % max. 10 kV DC 10 GΩ to 100 GΩ CMC 3,5 % max. 10 kV DC 100 GΩ to 1 TΩ CMC 4 % max. 10 kV DC 1 TΩ to 10 TΩ CMC 6 % VKP02/05","search_zh":"绝缘电阻 / 电气安装测试仪、多功能测试仪、手持工具测试仪、绝缘和接触电阻测试仪 校准 – 电学量 使用电阻倍增器由标准电气安装测试仪校准器间接产生 max. 10 kV DC 350 MΩ 至 1 GΩ CMC 3,2 % max. 10 kV DC 1 GΩ 至 10 GΩ CMC 3,3 % max. 10 kV DC 10 GΩ 至 100 GΩ CMC 3,5 % max. 10 kV DC 100 GΩ 至 1 TΩ CMC 4 % max. 10 kV DC 1 TΩ 至 10 TΩ CMC 6 % VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2393d39e5420413bf52ee655","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja izolacji / mierniki do badań instalacji, testery wielofunkcyjne, testery elektronarzędzi, mierniki izolacji i rezystancji przejścia","test_object_en":"Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters","test_object_zh":"绝缘电阻 / 电气安装测试仪、多功能测试仪、手持工具测试仪、绝缘和接触电阻测试仪","test_object_cs":"Izolační odpor / revizní měřidla, multifunkční testery, testery ručního nářadí, měřidla izolace a přechodových odporů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"max. 450 V DC","range":"100 kΩ","cmc":"0,2 %"},{"name":"max. 930 V DC","range":"300 kΩ","cmc":"0,2 %"},{"name":"max. 1 550 V DC","range":"500 kΩ","cmc":"0,2 %"},{"name":"max. 1 980 V DC","range":"1 MΩ","cmc":"0,2 %"},{"name":"max. 3 010 V DC","range":"3 MΩ","cmc":"0,3 %"},{"name":"max. 5 kV DC","range":"5 MΩ","cmc":"0,3 %"},{"name":"max. 5 kV DC","range":"od 10 MΩ do 100 MΩ","cmc":"0,5 %"},{"name":"max. 5 kV DC","range":"od 100 MΩ do 1 GΩ","cmc":"1 %"}],"parameters_en":[{"name":"max. 450 V DC","range":"100 kΩ","cmc":"0,2 %"},{"name":"max. 930 V DC","range":"300 kΩ","cmc":"0,2 %"},{"name":"max. 1 550 V DC","range":"500 kΩ","cmc":"0,2 %"},{"name":"max. 1 980 V DC","range":"1 MΩ","cmc":"0,2 %"},{"name":"max. 3 010 V DC","range":"3 MΩ","cmc":"0,3 %"},{"name":"max. 5 kV DC","range":"5 MΩ","cmc":"0,3 %"},{"name":"max. 5 kV DC","range":"10 MΩ to 100 MΩ","cmc":"0,5 %"},{"name":"max. 5 kV DC","range":"100 MΩ to 1 GΩ","cmc":"1 %"}],"parameters_zh":[{"name":"max. 450 V DC","range":"100 kΩ","cmc":"0,2 %"},{"name":"max. 930 V DC","range":"300 kΩ","cmc":"0,2 %"},{"name":"max. 1 550 V DC","range":"500 kΩ","cmc":"0,2 %"},{"name":"max. 1 980 V DC","range":"1 MΩ","cmc":"0,2 %"},{"name":"max. 3 010 V DC","range":"3 MΩ","cmc":"0,3 %"},{"name":"max. 5 kV DC","range":"5 MΩ","cmc":"0,3 %"},{"name":"max. 5 kV DC","range":"10 MΩ 至 100 MΩ","cmc":"0,5 %"},{"name":"max. 5 kV DC","range":"100 MΩ 至 1 GΩ","cmc":"1 %"}],"parameters_cs":[{"name":"max. 450 V DC","range":"100 kΩ","cmc":"0,2 %"},{"name":"max. 930 V DC","range":"300 kΩ","cmc":"0,2 %"},{"name":"max. 1 550 V DC","range":"500 kΩ","cmc":"0,2 %"},{"name":"max. 1 980 V DC","range":"1 MΩ","cmc":"0,2 %"},{"name":"max. 3 010 V DC","range":"3 MΩ","cmc":"0,3 %"},{"name":"max. 5 kV DC","range":"5 MΩ","cmc":"0,3 %"},{"name":"max. 5 kV DC","range":"10 MΩ až 100 MΩ","cmc":"0,5 %"},{"name":"max. 5 kV DC","range":"100 MΩ až 1 GΩ","cmc":"1 %"}],"technique":"Pomiar bezpośredni na dekadzie rezystancyjnej","technique_en":"Direct measurement on a resistance decade","technique_zh":"在电阻箱上直接测量","technique_cs":"Přímé měření na odporové dekádě","techniques":["Pomiar bezpośredni na dekadzie rezystancyjnej"],"techniques_en":["Direct measurement on a resistance decade"],"techniques_zh":["在电阻箱上直接测量"],"techniques_cs":["Přímé měření na odporové dekádě"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nmax. 450 V DC 100 kΩ CMC 0,2 %\nmax. 930 V DC 300 kΩ CMC 0,2 %\nmax. 1 550 V DC 500 kΩ CMC 0,2 %\nmax. 1 980 V DC 1 MΩ CMC 0,2 %\nmax. 3 010 V DC 3 MΩ CMC 0,3 %\nmax. 5 kV DC 5 MΩ CMC 0,3 %\nmax. 5 kV DC od 10 MΩ do 100 MΩ CMC 0,5 %\nmax. 5 kV DC od 100 MΩ do 1 GΩ CMC 1 %\nPomiar bezpośredni na dekadzie rezystancyjnej","reference":"VKP02/05","norm_bases":["VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja izolacji / mierniki do badań instalacji, testery wielofunkcyjne, testery elektronarzędzi, mierniki izolacji i rezystancji przejścia Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na dekadzie rezystancyjnej max. 450 V DC 100 kΩ CMC 0,2 % max. 930 V DC 300 kΩ CMC 0,2 % max. 1 550 V DC 500 kΩ CMC 0,2 % max. 1 980 V DC 1 MΩ CMC 0,2 % max. 3 010 V DC 3 MΩ CMC 0,3 % max. 5 kV DC 5 MΩ CMC 0,3 % max. 5 kV DC od 10 MΩ do 100 MΩ CMC 0,5 % max. 5 kV DC od 100 MΩ do 1 GΩ CMC 1 % Izolační odpor / revizní měřidla, multifunkční testery, testery ručního nářadí, měřidla izolace a přechodových odporů Kalibrace – elektrické veličiny Přímé měření na odporové dekádě max. 450 V DC 100 kΩ CMC 0,2 % max. 930 V DC 300 kΩ CMC 0,2 % max. 1 550 V DC 500 kΩ CMC 0,2 % max. 1 980 V DC 1 MΩ CMC 0,2 % max. 3 010 V DC 3 MΩ CMC 0,3 % max. 5 kV DC 5 MΩ CMC 0,3 % max. 5 kV DC 10 MΩ až 100 MΩ CMC 0,5 % max. 5 kV DC 100 MΩ až 1 GΩ CMC 1 % VKP02/05 Rezystancja izolacji / mierniki do badan instalacji, testery wielofunkcyjne, testery elektronarzedzi, mierniki izolacji i rezystancji przejscia Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na dekadzie rezystancyjnej max. 450 V DC 100 kΩ CMC 0,2 % max. 930 V DC 300 kΩ CMC 0,2 % max. 1 550 V DC 500 kΩ CMC 0,2 % max. 1 980 V DC 1 MΩ CMC 0,2 % max. 3 010 V DC 3 MΩ CMC 0,3 % max. 5 kV DC 5 MΩ CMC 0,3 % max. 5 kV DC od 10 MΩ do 100 MΩ CMC 0,5 % max. 5 kV DC od 100 MΩ do 1 GΩ CMC 1 % Izolacni odpor / revizni meridla, multifunkcni testery, testery rucniho naradi, meridla izolace a prechodovych odporu Kalibrace – elektricke veliciny Prime mereni na odporove dekade max. 450 V DC 100 kΩ CMC 0,2 % max. 930 V DC 300 kΩ CMC 0,2 % max. 1 550 V DC 500 kΩ CMC 0,2 % max. 1 980 V DC 1 MΩ CMC 0,2 % max. 3 010 V DC 3 MΩ CMC 0,3 % max. 5 kV DC 5 MΩ CMC 0,3 % max. 5 kV DC 10 MΩ az 100 MΩ CMC 0,5 % max. 5 kV DC 100 MΩ az 1 GΩ CMC 1 % VKP02/05","search_en":"Insulation resistance / installation testers, multifunction testers, hand tool testers, insulation and contact resistance meters Calibration – electrical quantities Direct measurement on a resistance decade max. 450 V DC 100 kΩ CMC 0,2 % max. 930 V DC 300 kΩ CMC 0,2 % max. 1 550 V DC 500 kΩ CMC 0,2 % max. 1 980 V DC 1 MΩ CMC 0,2 % max. 3 010 V DC 3 MΩ CMC 0,3 % max. 5 kV DC 5 MΩ CMC 0,3 % max. 5 kV DC 10 MΩ to 100 MΩ CMC 0,5 % max. 5 kV DC 100 MΩ to 1 GΩ CMC 1 % VKP02/05","search_zh":"绝缘电阻 / 电气安装测试仪、多功能测试仪、手持工具测试仪、绝缘和接触电阻测试仪 校准 – 电学量 在电阻箱上直接测量 max. 450 V DC 100 kΩ CMC 0,2 % max. 930 V DC 300 kΩ CMC 0,2 % max. 1 550 V DC 500 kΩ CMC 0,2 % max. 1 980 V DC 1 MΩ CMC 0,2 % max. 3 010 V DC 3 MΩ CMC 0,3 % max. 5 kV DC 5 MΩ CMC 0,3 % max. 5 kV DC 10 MΩ 至 100 MΩ CMC 0,5 % max. 5 kV DC 100 MΩ 至 1 GΩ CMC 1 % VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"661c4e819e70278a440b2d01","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"6","test_object":"Impedancja pętli zwarcia, impedancja sieci, impedancja uziemienia / mierniki do badań instalacji, testery wielofunkcyjne, mierniki impedancji sieci elektrycznej, mierniki rezystancji uziemień, mierniki uziemień","test_object_en":"Fault loop impedance, network impedance, earthing impedance / installation testers, multifunction testers, network impedance meters, earth resistance meters, earthing meters","test_object_zh":"故障回路阻抗、电网阻抗、接地阻抗 / 电气安装测试仪、多功能测试仪、电网阻抗测试仪、接地电阻测试仪、接地测量仪","test_object_cs":"Impedance ochranné smyčky, impedance sítě, impedance uzemnění / revizní měřidla, multifunkční testery měřidla impedance elektrické sítě, měřiče zemního odporu, měřiče uzemnění","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1000 mΩ","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"0,1 Ω"},{"name":"","range":"50 Ω","cmc":"0,3 Ω"},{"name":"","range":"100 Ω","cmc":"0,5 Ω"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2,5 Ω"},{"name":"","range":"1000 Ω","cmc":"5 Ω"},{"name":"","range":"1800 Ω","cmc":"10 Ω"}],"parameters_en":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1000 mΩ","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"0,1 Ω"},{"name":"","range":"50 Ω","cmc":"0,3 Ω"},{"name":"","range":"100 Ω","cmc":"0,5 Ω"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2,5 Ω"},{"name":"","range":"1000 Ω","cmc":"5 Ω"},{"name":"","range":"1800 Ω","cmc":"10 Ω"}],"parameters_zh":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1000 mΩ","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"0,1 Ω"},{"name":"","range":"50 Ω","cmc":"0,3 Ω"},{"name":"","range":"100 Ω","cmc":"0,5 Ω"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2,5 Ω"},{"name":"","range":"1000 Ω","cmc":"5 Ω"},{"name":"","range":"1800 Ω","cmc":"10 Ω"}],"parameters_cs":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1000 mΩ","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"0,1 Ω"},{"name":"","range":"50 Ω","cmc":"0,3 Ω"},{"name":"","range":"100 Ω","cmc":"0,5 Ω"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2,5 Ω"},{"name":"","range":"1000 Ω","cmc":"5 Ω"},{"name":"","range":"1800 Ω","cmc":"10 Ω"}],"technique":"Bezpośrednie generowanie kalibratorem mierników do badań instalacji","technique_en":"Direct generation by an installation tester calibrator","technique_zh":"用电气安装测试仪校准器直接产生","technique_cs":"Přímé generování kalibrátorem revizních přístrojů","techniques":["Bezpośrednie generowanie kalibratorem mierników do badań instalacji"],"techniques_en":["Direct generation by an installation tester calibrator"],"techniques_zh":["用电气安装测试仪校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n25 mΩ CMC 5 mΩ\n50 mΩ CMC 5 mΩ\n100 mΩ CMC 5 mΩ\n330 mΩ CMC 7 mΩ\n500 mΩ CMC 8 mΩ\n1000 mΩ CMC 10 mΩ\n1,8 Ω CMC 18 mΩ\n5 Ω CMC 30 mΩ\n10 Ω CMC 60 mΩ\n18 Ω CMC 0,1 Ω\n50 Ω CMC 0,3 Ω\n100 Ω CMC 0,5 Ω\n180 Ω CMC 1 Ω\n500 Ω CMC 2,5 Ω\n1000 Ω CMC 5 Ω\n1800 Ω CMC 10 Ω\nBezpośrednie generowanie kalibratorem mierników do badań instalacji","reference":"VKP02/05","norm_bases":["VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Impedancja pętli zwarcia, impedancja sieci, impedancja uziemienia / mierniki do badań instalacji, testery wielofunkcyjne, mierniki impedancji sieci elektrycznej, mierniki rezystancji uziemień, mierniki uziemień Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem mierników do badań instalacji 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1000 mΩ CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 0,1 Ω 50 Ω CMC 0,3 Ω 100 Ω CMC 0,5 Ω 180 Ω CMC 1 Ω 500 Ω CMC 2,5 Ω 1000 Ω CMC 5 Ω 1800 Ω CMC 10 Ω Impedance ochranné smyčky, impedance sítě, impedance uzemnění / revizní měřidla, multifunkční testery měřidla impedance elektrické sítě, měřiče zemního odporu, měřiče uzemnění Kalibrace – elektrické veličiny Přímé generování kalibrátorem revizních přístrojů 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1000 mΩ CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 0,1 Ω 50 Ω CMC 0,3 Ω 100 Ω CMC 0,5 Ω 180 Ω CMC 1 Ω 500 Ω CMC 2,5 Ω 1000 Ω CMC 5 Ω 1800 Ω CMC 10 Ω VKP02/05 Impedancja petli zwarcia, impedancja sieci, impedancja uziemienia / mierniki do badan instalacji, testery wielofunkcyjne, mierniki impedancji sieci elektrycznej, mierniki rezystancji uziemien, mierniki uziemien Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem miernikow do badan instalacji 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1000 mΩ CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 0,1 Ω 50 Ω CMC 0,3 Ω 100 Ω CMC 0,5 Ω 180 Ω CMC 1 Ω 500 Ω CMC 2,5 Ω 1000 Ω CMC 5 Ω 1800 Ω CMC 10 Ω Impedance ochranne smycky, impedance site, impedance uzemneni / revizni meridla, multifunkcni testery meridla impedance elektricke site, merice zemniho odporu, merice uzemneni Kalibrace – elektricke veliciny Prime generovani kalibratorem reviznich pristroju 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1000 mΩ CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 0,1 Ω 50 Ω CMC 0,3 Ω 100 Ω CMC 0,5 Ω 180 Ω CMC 1 Ω 500 Ω CMC 2,5 Ω 1000 Ω CMC 5 Ω 1800 Ω CMC 10 Ω VKP02/05","search_en":"Fault loop impedance, network impedance, earthing impedance / installation testers, multifunction testers, network impedance meters, earth resistance meters, earthing meters Calibration – electrical quantities Direct generation by an installation tester calibrator 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1000 mΩ CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 0,1 Ω 50 Ω CMC 0,3 Ω 100 Ω CMC 0,5 Ω 180 Ω CMC 1 Ω 500 Ω CMC 2,5 Ω 1000 Ω CMC 5 Ω 1800 Ω CMC 10 Ω VKP02/05","search_zh":"故障回路阻抗、电网阻抗、接地阻抗 / 电气安装测试仪、多功能测试仪、电网阻抗测试仪、接地电阻测试仪、接地测量仪 校准 – 电学量 用电气安装测试仪校准器直接产生 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1000 mΩ CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 0,1 Ω 50 Ω CMC 0,3 Ω 100 Ω CMC 0,5 Ω 180 Ω CMC 1 Ω 500 Ω CMC 2,5 Ω 1000 Ω CMC 5 Ω 1800 Ω CMC 10 Ω VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"748df7ef2b37ab2fae16b25b","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"7","test_object":"Moc prądu stałego / mierniki mocy prądu stałego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej","test_object_en":"DC power / DC power meters, clamp meters, multifunction testers, power network analysers","test_object_zh":"直流功率 / 直流功率表、钳形表、多功能测试仪、电网分析仪","test_object_cs":"Výkon stejnosměrný / měřidla stejnosměrného výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0,1 A do 1,2 A; U = max. 1020 V","range":"od 0,1 W do 30,8 kW","cmc":"0,013 %"},{"name":"1,2 A do 12 A; U = max. 1020 V","range":"od 0,1 W do 30,8 kW","cmc":"0,025 %"},{"name":"12 A do 30,2 A; U = max. 1020 V","range":"od 0,1 W do 30,8 kW","cmc":"0,08 %"}],"parameters_en":[{"name":"0,1 A to 1,2 A; U = max. 1020 V","range":"0,1 W to 30,8 kW","cmc":"0,013 %"},{"name":"1,2 A to 12 A; U = max. 1020 V","range":"0,1 W to 30,8 kW","cmc":"0,025 %"},{"name":"12 A to 30,2 A; U = max. 1020 V","range":"0,1 W to 30,8 kW","cmc":"0,08 %"}],"parameters_zh":[{"name":"0,1 A 至 1,2 A；U = max. 1020 V","range":"0,1 W 至 30,8 kW","cmc":"0,013 %"},{"name":"1,2 A 至 12 A；U = max. 1020 V","range":"0,1 W 至 30,8 kW","cmc":"0,025 %"},{"name":"12 A 至 30,2 A；U = max. 1020 V","range":"0,1 W 至 30,8 kW","cmc":"0,08 %"}],"parameters_cs":[{"name":"0,1 A až 1,2 A; U = max. 1020 V","range":"0,1 W až 30,8 kW","cmc":"0,013 %"},{"name":"1,2 A až 12 A; U = max. 1020 V","range":"0,1 W až 30,8 kW","cmc":"0,025 %"},{"name":"12 A až 30,2 A; U = max. 1020 V","range":"0,1 W až 30,8 kW","cmc":"0,08 %"}],"technique":"Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej","technique_en":"Power simulation by a calibrator with direct generation of the voltage and current components","technique_zh":"用校准器直接产生电压和电流分量模拟功率","technique_cs":"Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky","techniques":["Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej"],"techniques_en":["Power simulation by a calibrator with direct generation of the voltage and current components"],"techniques_zh":["用校准器直接产生电压和电流分量模拟功率"],"techniques_cs":["Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,1 A do 1,2 A; U = max. 1020 V od 0,1 W do 30,8 kW CMC 0,013 %\n1,2 A do 12 A; U = max. 1020 V od 0,1 W do 30,8 kW CMC 0,025 %\n12 A do 30,2 A; U = max. 1020 V od 0,1 W do 30,8 kW CMC 0,08 %\nSymulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / mierniki mocy prądu stałego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkości elektryczne Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej 0,1 A do 1,2 A; U = max. 1020 V od 0,1 W do 30,8 kW CMC 0,013 % 1,2 A do 12 A; U = max. 1020 V od 0,1 W do 30,8 kW CMC 0,025 % 12 A do 30,2 A; U = max. 1020 V od 0,1 W do 30,8 kW CMC 0,08 % Výkon stejnosměrný / měřidla stejnosměrného výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě Kalibrace – elektrické veličiny Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky 0,1 A až 1,2 A; U = max. 1020 V 0,1 W až 30,8 kW CMC 0,013 % 1,2 A až 12 A; U = max. 1020 V 0,1 W až 30,8 kW CMC 0,025 % 12 A až 30,2 A; U = max. 1020 V 0,1 W až 30,8 kW CMC 0,08 % VKP01/05 Moc pradu stalego / mierniki mocy pradu stalego, mierniki cegowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkosci elektryczne Symulacja mocy kalibratorem przez bezposrednie generowanie skladowej napieciowej i pradowej 0,1 A do 1,2 A; U = max. 1020 V od 0,1 W do 30,8 kW CMC 0,013 % 1,2 A do 12 A; U = max. 1020 V od 0,1 W do 30,8 kW CMC 0,025 % 12 A do 30,2 A; U = max. 1020 V od 0,1 W do 30,8 kW CMC 0,08 % Vykon stejnosmerny / meridla stejnosmerneho vykonu, klestova meridla, multifunkcni testery, analyzatory elektricke site Kalibrace – elektricke veliciny Simulace vykonu kalibratorem primym generovanim napetove a proudove slozky 0,1 A az 1,2 A; U = max. 1020 V 0,1 W az 30,8 kW CMC 0,013 % 1,2 A az 12 A; U = max. 1020 V 0,1 W az 30,8 kW CMC 0,025 % 12 A az 30,2 A; U = max. 1020 V 0,1 W az 30,8 kW CMC 0,08 % VKP01/05","search_en":"DC power / DC power meters, clamp meters, multifunction testers, power network analysers Calibration – electrical quantities Power simulation by a calibrator with direct generation of the voltage and current components 0,1 A to 1,2 A; U = max. 1020 V 0,1 W to 30,8 kW CMC 0,013 % 1,2 A to 12 A; U = max. 1020 V 0,1 W to 30,8 kW CMC 0,025 % 12 A to 30,2 A; U = max. 1020 V 0,1 W to 30,8 kW CMC 0,08 % VKP01/05","search_zh":"直流功率 / 直流功率表、钳形表、多功能测试仪、电网分析仪 校准 – 电学量 用校准器直接产生电压和电流分量模拟功率 0,1 A 至 1,2 A；U = max. 1020 V 0,1 W 至 30,8 kW CMC 0,013 % 1,2 A 至 12 A；U = max. 1020 V 0,1 W 至 30,8 kW CMC 0,025 % 12 A 至 30,2 A；U = max. 1020 V 0,1 W 至 30,8 kW CMC 0,08 % VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"724f354b9ef532c3af539ac2","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"7","test_object":"Moc prądu stałego / mierniki mocy prądu stałego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej","test_object_en":"DC power / DC power meters, clamp meters, multifunction testers, power network analysers","test_object_zh":"直流功率 / 直流功率表、钳形表、多功能测试仪、电网分析仪","test_object_cs":"Výkon stejnosměrný / měřidla stejnosměrného výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 A do 1000 A; U = max. 1020 V","range":"od 10 W do 1020 kW","cmc":"0,5 %"}],"parameters_en":[{"name":"10 A to 1000 A; U = max. 1020 V","range":"10 W to 1020 kW","cmc":"0,5 %"}],"parameters_zh":[{"name":"10 A 至 1000 A；U = max. 1020 V","range":"10 W 至 1020 kW","cmc":"0,5 %"}],"parameters_cs":[{"name":"10 A až 1000 A; U = max. 1020 V","range":"10 W až 1020 kW","cmc":"0,5 %"}],"technique":"Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową","technique_en":"Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil","technique_zh":"用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率","technique_cs":"Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou","techniques":["Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową"],"techniques_en":["Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil"],"techniques_zh":["用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率"],"techniques_cs":["Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n10 A do 1000 A; U = max. 1020 V od 10 W do 1020 kW CMC 0,5 %\nSymulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / mierniki mocy prądu stałego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkości elektryczne Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową 10 A do 1000 A; U = max. 1020 V od 10 W do 1020 kW CMC 0,5 % Výkon stejnosměrný / měřidla stejnosměrného výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě Kalibrace – elektrické veličiny Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou 10 A až 1000 A; U = max. 1020 V 10 W až 1020 kW CMC 0,5 % VKP01/05 Moc pradu stalego / mierniki mocy pradu stalego, mierniki cegowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkosci elektryczne Symulacja mocy kalibratorem przez bezposrednie generowanie skladowej napieciowej i posrednie generowanie skladowej pradowej z symulacja pradu cewka pradowa 10 A do 1000 A; U = max. 1020 V od 10 W do 1020 kW CMC 0,5 % Vykon stejnosmerny / meridla stejnosmerneho vykonu, klestova meridla, multifunkcni testery, analyzatory elektricke site Kalibrace – elektricke veliciny Simulace vykonu kalibratorem primym generovanim napetove a neprimym generovanim proudove slozky simulaci proudu proudovou civkou 10 A az 1000 A; U = max. 1020 V 10 W az 1020 kW CMC 0,5 % VKP01/05","search_en":"DC power / DC power meters, clamp meters, multifunction testers, power network analysers Calibration – electrical quantities Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil 10 A to 1000 A; U = max. 1020 V 10 W to 1020 kW CMC 0,5 % VKP01/05","search_zh":"直流功率 / 直流功率表、钳形表、多功能测试仪、电网分析仪 校准 – 电学量 用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率 10 A 至 1000 A；U = max. 1020 V 10 W 至 1020 kW CMC 0,5 % VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6dac555fead68bce75b38d01","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"8","test_object":"Moc czynna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej","test_object_en":"AC active power / AC power meters, clamp meters, multifunction testers, power network analysers","test_object_zh":"交流有功功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪","test_object_cs":"Výkon střídavý činný / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 1","range":"od 0,1 W do 30,08 kW","cmc":"0,06 %"},{"name":"45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,9","range":"od 0,09 W do 27,73 kW","cmc":"0,12 %"},{"name":"45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,7","range":"od 0,07 W do 21,55 kW","cmc":"0,20 %"},{"name":"45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,5","range":"od 0,05 W do 15,4 kW","cmc":"0,38 %"}],"parameters_en":[{"name":"45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 1","range":"0,1 W to 30,08 kW","cmc":"0,06 %"},{"name":"45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 0,9","range":"0,09 W to 27,73 kW","cmc":"0,12 %"},{"name":"45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 0,7","range":"0,07 W to 21,55 kW","cmc":"0,20 %"},{"name":"45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 0,5","range":"0,05 W to 15,4 kW","cmc":"0,38 %"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz；U = 最大 1 020 V；I = max. 30,2 A; cos φ = 1","range":"0,1 W 至 30,08 kW","cmc":"0,06 %"},{"name":"45 Hz 至 65 Hz；U = 最大 1 020 V；I = max. 30,2 A; cos φ = 0,9","range":"0,09 W 至 27,73 kW","cmc":"0,12 %"},{"name":"45 Hz 至 65 Hz；U = 最大 1 020 V；I = max. 30,2 A; cos φ = 0,7","range":"0,07 W 至 21,55 kW","cmc":"0,20 %"},{"name":"45 Hz 至 65 Hz；U = 最大 1 020 V；I = max. 30,2 A; cos φ = 0,5","range":"0,05 W 至 15,4 kW","cmc":"0,38 %"}],"parameters_cs":[{"name":"45 Hz až 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 1","range":"0,1 W až 30,08 kW","cmc":"0,06 %"},{"name":"45 Hz až 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 0,9","range":"0,09 W až 27,73 kW","cmc":"0,12 %"},{"name":"45 Hz až 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 0,7","range":"0,07 W až 21,55 kW","cmc":"0,20 %"},{"name":"45 Hz až 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 0,5","range":"0,05 W až 15,4 kW","cmc":"0,38 %"}],"technique":"Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej","technique_en":"Power simulation by a calibrator with direct generation of the voltage and current components","technique_zh":"用校准器直接产生电压和电流分量模拟功率","technique_cs":"Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky","techniques":["Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej"],"techniques_en":["Power simulation by a calibrator with direct generation of the voltage and current components"],"techniques_zh":["用校准器直接产生电压和电流分量模拟功率"],"techniques_cs":["Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 1 od 0,1 W do 30,08 kW CMC 0,06 %\n45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,9 od 0,09 W do 27,73 kW CMC 0,12 %\n45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,7 od 0,07 W do 21,55 kW CMC 0,20 %\n45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,5 od 0,05 W do 15,4 kW CMC 0,38 %\nSymulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkości elektryczne Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej 45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 1 od 0,1 W do 30,08 kW CMC 0,06 % 45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,9 od 0,09 W do 27,73 kW CMC 0,12 % 45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,7 od 0,07 W do 21,55 kW CMC 0,20 % 45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,5 od 0,05 W do 15,4 kW CMC 0,38 % Výkon střídavý činný / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě Kalibrace – elektrické veličiny Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky 45 Hz až 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 1 0,1 W až 30,08 kW CMC 0,06 % 45 Hz až 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 0,9 0,09 W až 27,73 kW CMC 0,12 % 45 Hz až 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 0,7 0,07 W až 21,55 kW CMC 0,20 % 45 Hz až 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 0,5 0,05 W až 15,4 kW CMC 0,38 % VKP01/05 Moc czynna pradu przemiennego / mierniki mocy pradu przemiennego, mierniki cegowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkosci elektryczne Symulacja mocy kalibratorem przez bezposrednie generowanie skladowej napieciowej i pradowej 45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 1 od 0,1 W do 30,08 kW CMC 0,06 % 45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,9 od 0,09 W do 27,73 kW CMC 0,12 % 45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,7 od 0,07 W do 21,55 kW CMC 0,20 % 45 Hz do 65 Hz; U = maks. 1 020 V; I = max. 30,2 A; cos φ = 0,5 od 0,05 W do 15,4 kW CMC 0,38 % Vykon stridavy cinny / meridla stridaveho vykonu, klestova meridla, multifunkcni testery, analyzatory elektricke site Kalibrace – elektricke veliciny Simulace vykonu kalibratorem primym generovanim napetove a proudove slozky 45 Hz az 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 1 0,1 W az 30,08 kW CMC 0,06 % 45 Hz az 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 0,9 0,09 W az 27,73 kW CMC 0,12 % 45 Hz az 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 0,7 0,07 W az 21,55 kW CMC 0,20 % 45 Hz az 65 Hz; U = max. 1 020 V; I = max. 30,2 A; cos φ = 0,5 0,05 W az 15,4 kW CMC 0,38 % VKP01/05","search_en":"AC active power / AC power meters, clamp meters, multifunction testers, power network analysers Calibration – electrical quantities Power simulation by a calibrator with direct generation of the voltage and current components 45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 1 0,1 W to 30,08 kW CMC 0,06 % 45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 0,9 0,09 W to 27,73 kW CMC 0,12 % 45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 0,7 0,07 W to 21,55 kW CMC 0,20 % 45 Hz to 65 Hz; U = max. 1,020 V; I = max. 30,2 A; cos φ = 0,5 0,05 W to 15,4 kW CMC 0,38 % VKP01/05","search_zh":"交流有功功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪 校准 – 电学量 用校准器直接产生电压和电流分量模拟功率 45 Hz 至 65 Hz；U = 最大 1 020 V；I = max. 30,2 A; cos φ = 1 0,1 W 至 30,08 kW CMC 0,06 % 45 Hz 至 65 Hz；U = 最大 1 020 V；I = max. 30,2 A; cos φ = 0,9 0,09 W 至 27,73 kW CMC 0,12 % 45 Hz 至 65 Hz；U = 最大 1 020 V；I = max. 30,2 A; cos φ = 0,7 0,07 W 至 21,55 kW CMC 0,20 % 45 Hz 至 65 Hz；U = 最大 1 020 V；I = max. 30,2 A; cos φ = 0,5 0,05 W 至 15,4 kW CMC 0,38 % VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff7bb846aea6a3e032a25a5f","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"8","test_object":"Moc czynna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej","test_object_en":"AC active power / AC power meters, clamp meters, multifunction testers, power network analysers","test_object_zh":"交流有功功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪","test_object_cs":"Výkon střídavý činný / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"I = max. 1 000 A; cos φ = 1","range":"od 10 W do 1020 kW","cmc":"0,50 %"},{"name":"I = max. 1 000 A; cos φ = 0,9","range":"od 9 W do 918 kW","cmc":"0,52 %"},{"name":"I = max. 1 000 A; cos φ = 0,7","range":"od 7 W do 714 kW","cmc":"0,54 %"},{"name":"I = max. 1 000 A; cos φ = 0,5","range":"od 5 W do 510 kW","cmc":"0,63 %"}],"parameters_en":[{"name":"I = max. 1 000 A; cos φ = 1","range":"10 W to 1020 kW","cmc":"0,50 %"},{"name":"I = max. 1 000 A; cos φ = 0,9","range":"9 W to 918 kW","cmc":"0,52 %"},{"name":"I = max. 1 000 A; cos φ = 0,7","range":"7 W to 714 kW","cmc":"0,54 %"},{"name":"I = max. 1 000 A; cos φ = 0,5","range":"5 W to 510 kW","cmc":"0,63 %"}],"parameters_zh":[{"name":"I = max. 1 000 A; cos φ = 1","range":"10 W 至 1020 kW","cmc":"0,50 %"},{"name":"I = max. 1 000 A; cos φ = 0,9","range":"9 W 至 918 kW","cmc":"0,52 %"},{"name":"I = max. 1 000 A; cos φ = 0,7","range":"7 W 至 714 kW","cmc":"0,54 %"},{"name":"I = max. 1 000 A; cos φ = 0,5","range":"5 W 至 510 kW","cmc":"0,63 %"}],"parameters_cs":[{"name":"I = max. 1 000 A; cos φ = 1","range":"10 W až 1020 kW","cmc":"0,50 %"},{"name":"I = max. 1 000 A; cos φ = 0,9","range":"9 W až 918 kW","cmc":"0,52 %"},{"name":"I = max. 1 000 A; cos φ = 0,7","range":"7 W až 714 kW","cmc":"0,54 %"},{"name":"I = max. 1 000 A; cos φ = 0,5","range":"5 W až 510 kW","cmc":"0,63 %"}],"technique":"Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową","technique_en":"Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil","technique_zh":"用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率","technique_cs":"Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou","techniques":["Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową"],"techniques_en":["Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil"],"techniques_zh":["用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率"],"techniques_cs":["Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nI = max. 1 000 A; cos φ = 1 od 10 W do 1020 kW CMC 0,50 %\nI = max. 1 000 A; cos φ = 0,9 od 9 W do 918 kW CMC 0,52 %\nI = max. 1 000 A; cos φ = 0,7 od 7 W do 714 kW CMC 0,54 %\nI = max. 1 000 A; cos φ = 0,5 od 5 W do 510 kW CMC 0,63 %\nSymulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkości elektryczne Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową I = max. 1 000 A; cos φ = 1 od 10 W do 1020 kW CMC 0,50 % I = max. 1 000 A; cos φ = 0,9 od 9 W do 918 kW CMC 0,52 % I = max. 1 000 A; cos φ = 0,7 od 7 W do 714 kW CMC 0,54 % I = max. 1 000 A; cos φ = 0,5 od 5 W do 510 kW CMC 0,63 % Výkon střídavý činný / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě Kalibrace – elektrické veličiny Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou I = max. 1 000 A; cos φ = 1 10 W až 1020 kW CMC 0,50 % I = max. 1 000 A; cos φ = 0,9 9 W až 918 kW CMC 0,52 % I = max. 1 000 A; cos φ = 0,7 7 W až 714 kW CMC 0,54 % I = max. 1 000 A; cos φ = 0,5 5 W až 510 kW CMC 0,63 % VKP01/05 Moc czynna pradu przemiennego / mierniki mocy pradu przemiennego, mierniki cegowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkosci elektryczne Symulacja mocy kalibratorem przez bezposrednie generowanie skladowej napieciowej i posrednie generowanie skladowej pradowej z symulacja pradu cewka pradowa I = max. 1 000 A; cos φ = 1 od 10 W do 1020 kW CMC 0,50 % I = max. 1 000 A; cos φ = 0,9 od 9 W do 918 kW CMC 0,52 % I = max. 1 000 A; cos φ = 0,7 od 7 W do 714 kW CMC 0,54 % I = max. 1 000 A; cos φ = 0,5 od 5 W do 510 kW CMC 0,63 % Vykon stridavy cinny / meridla stridaveho vykonu, klestova meridla, multifunkcni testery, analyzatory elektricke site Kalibrace – elektricke veliciny Simulace vykonu kalibratorem primym generovanim napetove a neprimym generovanim proudove slozky simulaci proudu proudovou civkou I = max. 1 000 A; cos φ = 1 10 W az 1020 kW CMC 0,50 % I = max. 1 000 A; cos φ = 0,9 9 W az 918 kW CMC 0,52 % I = max. 1 000 A; cos φ = 0,7 7 W az 714 kW CMC 0,54 % I = max. 1 000 A; cos φ = 0,5 5 W az 510 kW CMC 0,63 % VKP01/05","search_en":"AC active power / AC power meters, clamp meters, multifunction testers, power network analysers Calibration – electrical quantities Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil I = max. 1 000 A; cos φ = 1 10 W to 1020 kW CMC 0,50 % I = max. 1 000 A; cos φ = 0,9 9 W to 918 kW CMC 0,52 % I = max. 1 000 A; cos φ = 0,7 7 W to 714 kW CMC 0,54 % I = max. 1 000 A; cos φ = 0,5 5 W to 510 kW CMC 0,63 % VKP01/05","search_zh":"交流有功功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪 校准 – 电学量 用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率 I = max. 1 000 A; cos φ = 1 10 W 至 1020 kW CMC 0,50 % I = max. 1 000 A; cos φ = 0,9 9 W 至 918 kW CMC 0,52 % I = max. 1 000 A; cos φ = 0,7 7 W 至 714 kW CMC 0,54 % I = max. 1 000 A; cos φ = 0,5 5 W 至 510 kW CMC 0,63 % VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c641f873a4f3ff24ca5633d1","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"8","test_object":"Moc pozorna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej","test_object_en":"AC apparent power / AC power meters, clamp meters, multifunction testers, power network analysers","test_object_zh":"交流视在功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪","test_object_cs":"Výkon střídavý zdánlivý / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"I = max. 30,2 A","range":"od 0,1 VA do 30,08 kVA","cmc":"0,06 %"}],"parameters_en":[{"name":"I = max. 30,2 A","range":"0,1 VA to 30,08 kVA","cmc":"0,06 %"}],"parameters_zh":[{"name":"I = max. 30,2 A","range":"0,1 VA 至 30,08 kVA","cmc":"0,06 %"}],"parameters_cs":[{"name":"I = max. 30,2 A","range":"0,1 VA až 30,08 kVA","cmc":"0,06 %"}],"technique":"Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej","technique_en":"Power simulation by a calibrator with direct generation of the voltage and current components","technique_zh":"用校准器直接产生电压和电流分量模拟功率","technique_cs":"Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky","techniques":["Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej"],"techniques_en":["Power simulation by a calibrator with direct generation of the voltage and current components"],"techniques_zh":["用校准器直接产生电压和电流分量模拟功率"],"techniques_cs":["Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nI = max. 30,2 A od 0,1 VA do 30,08 kVA CMC 0,06 %\nSymulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc pozorna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkości elektryczne Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej I = max. 30,2 A od 0,1 VA do 30,08 kVA CMC 0,06 % Výkon střídavý zdánlivý / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě Kalibrace – elektrické veličiny Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky I = max. 30,2 A 0,1 VA až 30,08 kVA CMC 0,06 % VKP01/05 Moc pozorna pradu przemiennego / mierniki mocy pradu przemiennego, mierniki cegowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkosci elektryczne Symulacja mocy kalibratorem przez bezposrednie generowanie skladowej napieciowej i pradowej I = max. 30,2 A od 0,1 VA do 30,08 kVA CMC 0,06 % Vykon stridavy zdanlivy / meridla stridaveho vykonu, klestova meridla, multifunkcni testery, analyzatory elektricke site Kalibrace – elektricke veliciny Simulace vykonu kalibratorem primym generovanim napetove a proudove slozky I = max. 30,2 A 0,1 VA az 30,08 kVA CMC 0,06 % VKP01/05","search_en":"AC apparent power / AC power meters, clamp meters, multifunction testers, power network analysers Calibration – electrical quantities Power simulation by a calibrator with direct generation of the voltage and current components I = max. 30,2 A 0,1 VA to 30,08 kVA CMC 0,06 % VKP01/05","search_zh":"交流视在功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪 校准 – 电学量 用校准器直接产生电压和电流分量模拟功率 I = max. 30,2 A 0,1 VA 至 30,08 kVA CMC 0,06 % VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"46f088b08c6f4897502a7ae6","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"8","test_object":"Moc pozorna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej","test_object_en":"AC apparent power / AC power meters, clamp meters, multifunction testers, power network analysers","test_object_zh":"交流视在功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪","test_object_cs":"Výkon střídavý zdánlivý / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"I = max. 1 000 A","range":"od 10 VA do 1020 kVA","cmc":"0,50 %"}],"parameters_en":[{"name":"I = max. 1 000 A","range":"10 VA to 1020 kVA","cmc":"0,50 %"}],"parameters_zh":[{"name":"I = max. 1 000 A","range":"10 VA 至 1020 kVA","cmc":"0,50 %"}],"parameters_cs":[{"name":"I = max. 1 000 A","range":"10 VA až 1020 kVA","cmc":"0,50 %"}],"technique":"Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową","technique_en":"Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil","technique_zh":"用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率","technique_cs":"Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou","techniques":["Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową"],"techniques_en":["Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil"],"techniques_zh":["用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率"],"techniques_cs":["Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nI = max. 1 000 A od 10 VA do 1020 kVA CMC 0,50 %\nSymulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc pozorna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkości elektryczne Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową I = max. 1 000 A od 10 VA do 1020 kVA CMC 0,50 % Výkon střídavý zdánlivý / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě Kalibrace – elektrické veličiny Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou I = max. 1 000 A 10 VA až 1020 kVA CMC 0,50 % VKP01/05 Moc pozorna pradu przemiennego / mierniki mocy pradu przemiennego, mierniki cegowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkosci elektryczne Symulacja mocy kalibratorem przez bezposrednie generowanie skladowej napieciowej i posrednie generowanie skladowej pradowej z symulacja pradu cewka pradowa I = max. 1 000 A od 10 VA do 1020 kVA CMC 0,50 % Vykon stridavy zdanlivy / meridla stridaveho vykonu, klestova meridla, multifunkcni testery, analyzatory elektricke site Kalibrace – elektricke veliciny Simulace vykonu kalibratorem primym generovanim napetove a neprimym generovanim proudove slozky simulaci proudu proudovou civkou I = max. 1 000 A 10 VA az 1020 kVA CMC 0,50 % VKP01/05","search_en":"AC apparent power / AC power meters, clamp meters, multifunction testers, power network analysers Calibration – electrical quantities Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil I = max. 1 000 A 10 VA to 1020 kVA CMC 0,50 % VKP01/05","search_zh":"交流视在功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪 校准 – 电学量 用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率 I = max. 1 000 A 10 VA 至 1020 kVA CMC 0,50 % VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9e6c052cce71e2cd844c3b37","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"8","test_object":"Moc bierna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej","test_object_en":"AC reactive power / AC power meters, clamp meters, multifunction testers, power network analysers","test_object_zh":"交流无功功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪","test_object_cs":"Výkon střídavý jalový / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"Cos φ = 0,5; I = max. 30,2 A","range":"od 0,05 VAr do 15,4 kVAr","cmc":"0,38 %"}],"parameters_en":[{"name":"Cos φ = 0,5; I = max. 30,2 A","range":"0,05 VAr to 15,4 kVAr","cmc":"0,38 %"}],"parameters_zh":[{"name":"Cos φ = 0,5; I = max. 30,2 A","range":"0,05 VAr 至 15,4 kVAr","cmc":"0,38 %"}],"parameters_cs":[{"name":"Cos φ = 0,5; I = max. 30,2 A","range":"0,05 VAr až 15,4 kVAr","cmc":"0,38 %"}],"technique":"Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej","technique_en":"Power simulation by a calibrator with direct generation of the voltage and current components","technique_zh":"用校准器直接产生电压和电流分量模拟功率","technique_cs":"Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky","techniques":["Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej"],"techniques_en":["Power simulation by a calibrator with direct generation of the voltage and current components"],"techniques_zh":["用校准器直接产生电压和电流分量模拟功率"],"techniques_cs":["Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nCos φ = 0,5; I = max. 30,2 A od 0,05 VAr do 15,4 kVAr CMC 0,38 %\nSymulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc bierna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkości elektryczne Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i prądowej Cos φ = 0,5; I = max. 30,2 A od 0,05 VAr do 15,4 kVAr CMC 0,38 % Výkon střídavý jalový / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě Kalibrace – elektrické veličiny Simulace výkonu kalibrátorem přímým generováním napěťové a proudové složky Cos φ = 0,5; I = max. 30,2 A 0,05 VAr až 15,4 kVAr CMC 0,38 % VKP01/05 Moc bierna pradu przemiennego / mierniki mocy pradu przemiennego, mierniki cegowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkosci elektryczne Symulacja mocy kalibratorem przez bezposrednie generowanie skladowej napieciowej i pradowej Cos φ = 0,5; I = max. 30,2 A od 0,05 VAr do 15,4 kVAr CMC 0,38 % Vykon stridavy jalovy / meridla stridaveho vykonu, klestova meridla, multifunkcni testery, analyzatory elektricke site Kalibrace – elektricke veliciny Simulace vykonu kalibratorem primym generovanim napetove a proudove slozky Cos φ = 0,5; I = max. 30,2 A 0,05 VAr az 15,4 kVAr CMC 0,38 % VKP01/05","search_en":"AC reactive power / AC power meters, clamp meters, multifunction testers, power network analysers Calibration – electrical quantities Power simulation by a calibrator with direct generation of the voltage and current components Cos φ = 0,5; I = max. 30,2 A 0,05 VAr to 15,4 kVAr CMC 0,38 % VKP01/05","search_zh":"交流无功功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪 校准 – 电学量 用校准器直接产生电压和电流分量模拟功率 Cos φ = 0,5; I = max. 30,2 A 0,05 VAr 至 15,4 kVAr CMC 0,38 % VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2438724433c623db0b6eee36","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"8","test_object":"Moc bierna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej","test_object_en":"AC reactive power / AC power meters, clamp meters, multifunction testers, power network analysers","test_object_zh":"交流无功功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪","test_object_cs":"Výkon střídavý jalový / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"I = max. 1 000 A","range":"od 5 VAr do 510 kVAr","cmc":"0,63 %"}],"parameters_en":[{"name":"I = max. 1 000 A","range":"5 VAr to 510 kVAr","cmc":"0,63 %"}],"parameters_zh":[{"name":"I = max. 1 000 A","range":"5 VAr 至 510 kVAr","cmc":"0,63 %"}],"parameters_cs":[{"name":"I = max. 1 000 A","range":"5 VAr až 510 kVAr","cmc":"0,63 %"}],"technique":"Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową","technique_en":"Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil","technique_zh":"用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率","technique_cs":"Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou","techniques":["Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową"],"techniques_en":["Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil"],"techniques_zh":["用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率"],"techniques_cs":["Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nI = max. 1 000 A od 5 VAr do 510 kVAr CMC 0,63 %\nSymulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc bierna prądu przemiennego / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkości elektryczne Symulacja mocy kalibratorem przez bezpośrednie generowanie składowej napięciowej i pośrednie generowanie składowej prądowej z symulacją prądu cewką prądową I = max. 1 000 A od 5 VAr do 510 kVAr CMC 0,63 % Výkon střídavý jalový / měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě Kalibrace – elektrické veličiny Simulace výkonu kalibrátorem přímým generováním napěťové a nepřímým generováním proudové složky simulací proudu proudovou cívkou I = max. 1 000 A 5 VAr až 510 kVAr CMC 0,63 % VKP01/05 Moc bierna pradu przemiennego / mierniki mocy pradu przemiennego, mierniki cegowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkosci elektryczne Symulacja mocy kalibratorem przez bezposrednie generowanie skladowej napieciowej i posrednie generowanie skladowej pradowej z symulacja pradu cewka pradowa I = max. 1 000 A od 5 VAr do 510 kVAr CMC 0,63 % Vykon stridavy jalovy / meridla stridaveho vykonu, klestova meridla, multifunkcni testery, analyzatory elektricke site Kalibrace – elektricke veliciny Simulace vykonu kalibratorem primym generovanim napetove a neprimym generovanim proudove slozky simulaci proudu proudovou civkou I = max. 1 000 A 5 VAr az 510 kVAr CMC 0,63 % VKP01/05","search_en":"AC reactive power / AC power meters, clamp meters, multifunction testers, power network analysers Calibration – electrical quantities Power simulation by a calibrator with direct generation of the voltage component and indirect generation of the current component by current simulation with a current coil I = max. 1 000 A 5 VAr to 510 kVAr CMC 0,63 % VKP01/05","search_zh":"交流无功功率 / 交流功率表、钳形表、多功能测试仪、电网分析仪 校准 – 电学量 用校准器直接产生电压分量并以电流线圈模拟电流间接产生电流分量来模拟功率 I = max. 1 000 A 5 VAr 至 510 kVAr CMC 0,63 % VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e2d7f0680cb9f955b95b379d","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"8","test_object":"Kąt fazowy (napięcie względem prądu) / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej","test_object_en":"Phase angle (voltage vs current) / AC power meters, clamp meters, multifunction testers, power network analysers","test_object_zh":"相位角（电压对电流）/ 交流功率表、钳形表、多功能测试仪、电网分析仪","test_object_cs":"Fázový úhel (napětí vs proud)/měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"3 Hz do 65 Hz; U = min. 1 V","range":"od -180° do 180°","cmc":"0,1°"},{"name":"65 Hz do 500 Hz; U = min. 1 V","range":"od -180° do 180°","cmc":"0.2°"},{"name":"500 Hz do 1 kHz; U = min. 1 V","range":"od -180° do 180°","cmc":"0.4°"},{"name":"1 kHz do 5 kHz; U = min. 1 V","range":"od -180° do 180°","cmc":"1.9°"},{"name":"5 kHz do 10 kHz; U = min. 1 V","range":"od -180° do 180°","cmc":"3.9°"},{"name":"10 kHz do 30 kHz; U = min. 1 V","range":"od -180° do 180°","cmc":"7.8°"}],"parameters_en":[{"name":"3 Hz to 65 Hz; U = min. 1 V","range":"-180° to 180°","cmc":"0,1°"},{"name":"65 Hz to 500 Hz; U = min. 1 V","range":"-180° to 180°","cmc":"0.2°"},{"name":"500 Hz to 1 kHz; U = min. 1 V","range":"-180° to 180°","cmc":"0.4°"},{"name":"1 kHz to 5 kHz; U = min. 1 V","range":"-180° to 180°","cmc":"1.9°"},{"name":"5 kHz to 10 kHz; U = min. 1 V","range":"-180° to 180°","cmc":"3.9°"},{"name":"10 kHz to 30 kHz; U = min. 1 V","range":"-180° to 180°","cmc":"7.8°"}],"parameters_zh":[{"name":"3 Hz 至 65 Hz；U = min. 1 V","range":"-180° 至 180°","cmc":"0,1°"},{"name":"65 Hz 至 500 Hz；U = min. 1 V","range":"-180° 至 180°","cmc":"0.2°"},{"name":"500 Hz 至 1 kHz；U = min. 1 V","range":"-180° 至 180°","cmc":"0.4°"},{"name":"1 kHz 至 5 kHz；U = min. 1 V","range":"-180° 至 180°","cmc":"1.9°"},{"name":"5 kHz 至 10 kHz；U = min. 1 V","range":"-180° 至 180°","cmc":"3.9°"},{"name":"10 kHz 至 30 kHz；U = min. 1 V","range":"-180° 至 180°","cmc":"7.8°"}],"parameters_cs":[{"name":"3 Hz až 65 Hz; U = min. 1 V","range":"-180° až 180°","cmc":"0,1°"},{"name":"65 Hz až 500 Hz; U = min. 1 V","range":"-180° až 180°","cmc":"0.2°"},{"name":"500 Hz až 1 kHz; U = min. 1 V","range":"-180° až 180°","cmc":"0.4°"},{"name":"1 kHz až 5 kHz; U = min. 1 V","range":"-180° až 180°","cmc":"1.9°"},{"name":"5 kHz až 10 kHz; U = min. 1 V","range":"-180° až 180°","cmc":"3.9°"},{"name":"10 kHz až 30 kHz; U = min. 1 V","range":"-180° až 180°","cmc":"7.8°"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation by a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation by a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n3 Hz do 65 Hz; U = min. 1 V od -180° do 180° CMC 0,1°\n65 Hz do 500 Hz; U = min. 1 V od -180° do 180° CMC 0.2°\n500 Hz do 1 kHz; U = min. 1 V od -180° do 180° CMC 0.4°\n1 kHz do 5 kHz; U = min. 1 V od -180° do 180° CMC 1.9°\n5 kHz do 10 kHz; U = min. 1 V od -180° do 180° CMC 3.9°\n10 kHz do 30 kHz; U = min. 1 V od -180° do 180° CMC 7.8°\nBezpośrednie generowanie kalibratorem","reference":"VKP01/05","norm_bases":["VKP01/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt fazowy (napięcie względem prądu) / mierniki mocy prądu przemiennego, mierniki cęgowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 3 Hz do 65 Hz; U = min. 1 V od -180° do 180° CMC 0,1° 65 Hz do 500 Hz; U = min. 1 V od -180° do 180° CMC 0.2° 500 Hz do 1 kHz; U = min. 1 V od -180° do 180° CMC 0.4° 1 kHz do 5 kHz; U = min. 1 V od -180° do 180° CMC 1.9° 5 kHz do 10 kHz; U = min. 1 V od -180° do 180° CMC 3.9° 10 kHz do 30 kHz; U = min. 1 V od -180° do 180° CMC 7.8° Fázový úhel (napětí vs proud)/měřidla střídavého výkonu, klešťová měřidla, multifunkční testery, analyzátory elektrické sítě Kalibrace – elektrické veličiny Přímé generování kalibrátorem 3 Hz až 65 Hz; U = min. 1 V -180° až 180° CMC 0,1° 65 Hz až 500 Hz; U = min. 1 V -180° až 180° CMC 0.2° 500 Hz až 1 kHz; U = min. 1 V -180° až 180° CMC 0.4° 1 kHz až 5 kHz; U = min. 1 V -180° až 180° CMC 1.9° 5 kHz až 10 kHz; U = min. 1 V -180° až 180° CMC 3.9° 10 kHz až 30 kHz; U = min. 1 V -180° až 180° CMC 7.8° VKP01/05 Kat fazowy (napiecie wzgledem pradu) / mierniki mocy pradu przemiennego, mierniki cegowe, testery wielofunkcyjne, analizatory sieci elektrycznej Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 3 Hz do 65 Hz; U = min. 1 V od -180° do 180° CMC 0,1° 65 Hz do 500 Hz; U = min. 1 V od -180° do 180° CMC 0.2° 500 Hz do 1 kHz; U = min. 1 V od -180° do 180° CMC 0.4° 1 kHz do 5 kHz; U = min. 1 V od -180° do 180° CMC 1.9° 5 kHz do 10 kHz; U = min. 1 V od -180° do 180° CMC 3.9° 10 kHz do 30 kHz; U = min. 1 V od -180° do 180° CMC 7.8° Fazovy uhel (napeti vs proud)/meridla stridaveho vykonu, klestova meridla, multifunkcni testery, analyzatory elektricke site Kalibrace – elektricke veliciny Prime generovani kalibratorem 3 Hz az 65 Hz; U = min. 1 V -180° az 180° CMC 0,1° 65 Hz az 500 Hz; U = min. 1 V -180° az 180° CMC 0.2° 500 Hz az 1 kHz; U = min. 1 V -180° az 180° CMC 0.4° 1 kHz az 5 kHz; U = min. 1 V -180° az 180° CMC 1.9° 5 kHz az 10 kHz; U = min. 1 V -180° az 180° CMC 3.9° 10 kHz az 30 kHz; U = min. 1 V -180° az 180° CMC 7.8° VKP01/05","search_en":"Phase angle (voltage vs current) / AC power meters, clamp meters, multifunction testers, power network analysers Calibration – electrical quantities Direct generation by a calibrator 3 Hz to 65 Hz; U = min. 1 V -180° to 180° CMC 0,1° 65 Hz to 500 Hz; U = min. 1 V -180° to 180° CMC 0.2° 500 Hz to 1 kHz; U = min. 1 V -180° to 180° CMC 0.4° 1 kHz to 5 kHz; U = min. 1 V -180° to 180° CMC 1.9° 5 kHz to 10 kHz; U = min. 1 V -180° to 180° CMC 3.9° 10 kHz to 30 kHz; U = min. 1 V -180° to 180° CMC 7.8° VKP01/05","search_zh":"相位角（电压对电流）/ 交流功率表、钳形表、多功能测试仪、电网分析仪 校准 – 电学量 用校准器直接产生 3 Hz 至 65 Hz；U = min. 1 V -180° 至 180° CMC 0,1° 65 Hz 至 500 Hz；U = min. 1 V -180° 至 180° CMC 0.2° 500 Hz 至 1 kHz；U = min. 1 V -180° 至 180° CMC 0.4° 1 kHz 至 5 kHz；U = min. 1 V -180° 至 180° CMC 1.9° 5 kHz 至 10 kHz；U = min. 1 V -180° 至 180° CMC 3.9° 10 kHz 至 30 kHz；U = min. 1 V -180° 至 180° CMC 7.8° VKP01/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8342c7057bc620bb84502180","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / mierniki napięcia i prądu przemiennego, mierniki mocy prądu przemiennego, analizatory sieci elektrycznej, multimetry, kalibratory, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień","test_object_en":"Frequency / AC voltage and current meters, AC power meters, power network analysers, multimeters, calibrators, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters","test_object_zh":"频率 / 交流电压和电流表、交流功率表、电网分析仪、万用表、校准器、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪","test_object_cs":"Frekvence / Měřidla střídavého napětí a proudu, měřidla střídavého výkonu, analyzátory elektrické sítě, multimetry, kalibrátory, klešťová měřidla, revizní měřidla, multifunkční testery, měřidla zemního odporu, měřidla uzemnění","methodology":"Wzorcowanie – częstotliwość","methodology_en":"Calibration – frequency","methodology_zh":"校准 – 频率","methodology_cs":"Kalibrace – frekvence","parameters":[{"name":"Napięcie przemienne","range":"od 10 Hz do 10 kHz","cmc":"25 × 10⁻⁶ +1 mHz"},{"name":"Napięcie przemienne","range":"od 10 kHz do 1 MHz","cmc":"25 × 10⁻⁶ +15 mHz"},{"name":"Prąd przemienny","range":"od 10 Hz do 10 kHz","cmc":"25 × 10⁻⁶ +1 mHz"}],"parameters_en":[{"name":"AC voltage","range":"10 Hz to 10 kHz","cmc":"25 × 10⁻⁶ +1 mHz"},{"name":"AC voltage","range":"10 kHz to 1 MHz","cmc":"25 × 10⁻⁶ +15 mHz"},{"name":"AC current","range":"10 Hz to 10 kHz","cmc":"25 × 10⁻⁶ +1 mHz"}],"parameters_zh":[{"name":"交流电压","range":"10 Hz 至 10 kHz","cmc":"25 × 10⁻⁶ +1 mHz"},{"name":"交流电压","range":"10 kHz 至 1 MHz","cmc":"25 × 10⁻⁶ +15 mHz"},{"name":"交流电流","range":"10 Hz 至 10 kHz","cmc":"25 × 10⁻⁶ +1 mHz"}],"parameters_cs":[{"name":"Střídavé napětí","range":"10 Hz až 10 kHz","cmc":"25 × 10⁻⁶ +1 mHz"},{"name":"Střídavé napětí","range":"10 kHz až 1 MHz","cmc":"25 × 10⁻⁶ +15 mHz"},{"name":"Střídavý proud","range":"10 Hz až 10 kHz","cmc":"25 × 10⁻⁶ +1 mHz"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation by a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation by a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – częstotliwość\nZakres:\nNapięcie przemienne od 10 Hz do 10 kHz CMC 25 × 10⁻⁶ +1 mHz\nNapięcie przemienne od 10 kHz do 1 MHz CMC 25 × 10⁻⁶ +15 mHz\nPrąd przemienny od 10 Hz do 10 kHz CMC 25 × 10⁻⁶ +1 mHz\nBezpośrednie generowanie kalibratorem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: częstotliwość","regulatory_area_en":"CMC for the field of measured quantity: Frequency","regulatory_area_zh":"被测量领域的CMC：频率","regulatory_area_cs":"CMC pro obor měřené veličiny: Frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / mierniki napięcia i prądu przemiennego, mierniki mocy prądu przemiennego, analizatory sieci elektrycznej, multimetry, kalibratory, mierniki cęgowe, mierniki do badań instalacji, testery wielofunkcyjne, mierniki rezystancji uziemień, mierniki uziemień Wzorcowanie – częstotliwość Bezpośrednie generowanie kalibratorem Napięcie przemienne od 10 Hz do 10 kHz CMC 25 × 10⁻⁶ +1 mHz Napięcie przemienne od 10 kHz do 1 MHz CMC 25 × 10⁻⁶ +15 mHz Prąd przemienny od 10 Hz do 10 kHz CMC 25 × 10⁻⁶ +1 mHz Frekvence / Měřidla střídavého napětí a proudu, měřidla střídavého výkonu, analyzátory elektrické sítě, multimetry, kalibrátory, klešťová měřidla, revizní měřidla, multifunkční testery, měřidla zemního odporu, měřidla uzemnění Kalibrace – frekvence Přímé generování kalibrátorem Střídavé napětí 10 Hz až 10 kHz CMC 25 × 10⁻⁶ +1 mHz Střídavé napětí 10 kHz až 1 MHz CMC 25 × 10⁻⁶ +15 mHz Střídavý proud 10 Hz až 10 kHz CMC 25 × 10⁻⁶ +1 mHz VKP01/05 VKP02/05 Czestotliwosc / mierniki napiecia i pradu przemiennego, mierniki mocy pradu przemiennego, analizatory sieci elektrycznej, multimetry, kalibratory, mierniki cegowe, mierniki do badan instalacji, testery wielofunkcyjne, mierniki rezystancji uziemien, mierniki uziemien Wzorcowanie – czestotliwosc Bezposrednie generowanie kalibratorem Napiecie przemienne od 10 Hz do 10 kHz CMC 25 × 10⁻⁶ +1 mHz Napiecie przemienne od 10 kHz do 1 MHz CMC 25 × 10⁻⁶ +15 mHz Prad przemienny od 10 Hz do 10 kHz CMC 25 × 10⁻⁶ +1 mHz Frekvence / Meridla stridaveho napeti a proudu, meridla stridaveho vykonu, analyzatory elektricke site, multimetry, kalibratory, klestova meridla, revizni meridla, multifunkcni testery, meridla zemniho odporu, meridla uzemneni Kalibrace – frekvence Prime generovani kalibratorem Stridave napeti 10 Hz az 10 kHz CMC 25 × 10⁻⁶ +1 mHz Stridave napeti 10 kHz az 1 MHz CMC 25 × 10⁻⁶ +15 mHz Stridavy proud 10 Hz az 10 kHz CMC 25 × 10⁻⁶ +1 mHz VKP01/05 VKP02/05","search_en":"Frequency / AC voltage and current meters, AC power meters, power network analysers, multimeters, calibrators, clamp meters, installation testers, multifunction testers, earth resistance meters, earthing meters Calibration – frequency Direct generation by a calibrator AC voltage 10 Hz to 10 kHz CMC 25 × 10⁻⁶ +1 mHz AC voltage 10 kHz to 1 MHz CMC 25 × 10⁻⁶ +15 mHz AC current 10 Hz to 10 kHz CMC 25 × 10⁻⁶ +1 mHz VKP01/05 VKP02/05","search_zh":"频率 / 交流电压和电流表、交流功率表、电网分析仪、万用表、校准器、钳形表、电气安装测试仪、多功能测试仪、接地电阻测试仪、接地测量仪 校准 – 频率 用校准器直接产生 交流电压 10 Hz 至 10 kHz CMC 25 × 10⁻⁶ +1 mHz 交流电压 10 kHz 至 1 MHz CMC 25 × 10⁻⁶ +15 mHz 交流电流 10 Hz 至 10 kHz CMC 25 × 10⁻⁶ +1 mHz VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f6a8fff0ab814ea6658794b2","lab_id":"6ade8b37ff06824761708119","country":"CZ","accr_number":"2332","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / źródła napięcia przemiennego","test_object_en":"Frequency / AC voltage sources","test_object_zh":"频率 / 交流电压源","test_object_cs":"Frekvence / zdroje střídavého napětí","methodology":"Wzorcowanie – częstotliwość","methodology_en":"Calibration – frequency","methodology_zh":"校准 – 频率","methodology_cs":"Kalibrace – frekvence","parameters":[{"name":"Napięcie przemienne","range":"od 10 Hz do 40 Hz","cmc":"0,03 %"},{"name":"Napięcie przemienne","range":"od 40 Hz do 300 kHz","cmc":"0,01 %"}],"parameters_en":[{"name":"AC voltage","range":"10 Hz to 40 Hz","cmc":"0,03 %"},{"name":"AC voltage","range":"40 Hz to 300 kHz","cmc":"0,01 %"}],"parameters_zh":[{"name":"交流电压","range":"10 Hz 至 40 Hz","cmc":"0,03 %"},{"name":"交流电压","range":"40 Hz 至 300 kHz","cmc":"0,01 %"}],"parameters_cs":[{"name":"Střídavé napětí","range":"10 Hz až 40 Hz","cmc":"0,03 %"},{"name":"Střídavé napětí","range":"40 Hz až 300 kHz","cmc":"0,01 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement by a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement by a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – częstotliwość\nZakres:\nNapięcie przemienne od 10 Hz do 40 Hz CMC 0,03 %\nNapięcie przemienne od 40 Hz do 300 kHz CMC 0,01 %\nPomiar bezpośredni multimetrem","reference":"VKP01/05 VKP02/05","norm_bases":["VKP01/05","VKP02/05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: częstotliwość","regulatory_area_en":"CMC for the field of measured quantity: Frequency","regulatory_area_zh":"被测量领域的CMC：频率","regulatory_area_cs":"CMC pro obor měřené veličiny: Frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / źródła napięcia przemiennego Wzorcowanie – częstotliwość Pomiar bezpośredni multimetrem Napięcie przemienne od 10 Hz do 40 Hz CMC 0,03 % Napięcie przemienne od 40 Hz do 300 kHz CMC 0,01 % Frekvence / zdroje střídavého napětí Kalibrace – frekvence Přímé měření multimetrem Střídavé napětí 10 Hz až 40 Hz CMC 0,03 % Střídavé napětí 40 Hz až 300 kHz CMC 0,01 % VKP01/05 VKP02/05 Czestotliwosc / zrodla napiecia przemiennego Wzorcowanie – czestotliwosc Pomiar bezposredni multimetrem Napiecie przemienne od 10 Hz do 40 Hz CMC 0,03 % Napiecie przemienne od 40 Hz do 300 kHz CMC 0,01 % Frekvence / zdroje stridaveho napeti Kalibrace – frekvence Prime mereni multimetrem Stridave napeti 10 Hz az 40 Hz CMC 0,03 % Stridave napeti 40 Hz az 300 kHz CMC 0,01 % VKP01/05 VKP02/05","search_en":"Frequency / AC voltage sources Calibration – frequency Direct measurement by a multimeter AC voltage 10 Hz to 40 Hz CMC 0,03 % AC voltage 40 Hz to 300 kHz CMC 0,01 % VKP01/05 VKP02/05","search_zh":"频率 / 交流电压源 校准 – 频率 用万用表直接测量 交流电压 10 Hz 至 40 Hz CMC 0,03 % 交流电压 40 Hz 至 300 kHz CMC 0,01 % VKP01/05 VKP02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}