TŘINECKÉ ŽELEZÁRNY, a. s. is a calibration laboratory accredited by ČIA under number 2331 (Třinec, Czech Republic). Its accreditation scope covers 10 calibration items in the following areas: Metrology & calibration. Calibrated items include: Deformation and digital pressure gauges, pressure transducers with…, Electronic thermometers, Radiation thermometers, Resistance thermometers. Most frequently used calibration principles: Comparison with a standard digital pressure gauge, Comparison with a standard resistance thermometer, Comparison with a standard digital thermometer.

At a glance

  • Accreditation number: ČIA 2331
  • Calibration items in scope: 10
  • Types of calibrated items: 6
  • Calibration principles used: 7
  • City: Třinec, Czech Republic
  • Valid until: 24-04-2028
Accreditation number
2331
Accreditation body
ČIA
Address
Průmyslová 1000, Staré Město, 739 61 Třinec
City
Třinec, Czech Republic
Division
KMS3 - Ośrodek Kontroli Metrologicznej jednostki VA
Valid until
24-04-2028

What this laboratory calibrates (6)

Calibration principles (7)

Certificate information

Certificate date
24.07.2026

Accreditation scope — calibration items (10)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Deformation and digital pressure gauges, pressure transducers with electrical output signal Calibration – pressure
gauge pressure; gas — -100 kPa to -70 kPa · CMC 60 Pa gauge pressure; gas — -70 kPa to -7,5 kPa · CMC 18 Pa gauge pressure; gas — -7,5 kPa to 0 kPa · CMC 4 Pa gauge pressure; gas — 0 kPa to 7,5 kPa · CMC 4 Pa gauge pressure; gas — 7,5 kPa to 70 kPa · CMC 18 Pa gauge pressure; gas — 70 kPa to 600 kPa · CMC 60 Pa gauge pressure; gas — 600 kPa to 7000 kPa · CMC 0,01 %
CMC for the field of measured quantity: Pressure
Comparison with a standard digital pressure gauge PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43
2 Deformation and digital pressure gauges, pressure transducers with electrical output signal Calibration – pressure
absolute pressure; gas — 0 kPa to 600 kPa · CMC 60 Pa absolute pressure; gas — 600 kPa to 7000 kPa · CMC 0,01 %
CMC for the field of measured quantity: Pressure
Comparison with a standard digital pressure gauge PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43
3 Deformation and digital pressure gauges, pressure transducers with electrical output signal Calibration – pressure
gauge pressure; liquid — 0 kPa to 100 kPa · CMC 1800 Pa gauge pressure; liquid — 100 kPa to 700 kPa · CMC 300 Pa
CMC for the field of measured quantity: Pressure
Comparison with a standard digital pressure gauge PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43
4 Deformation and digital pressure gauges, pressure transducers with electrical output signal Calibration – pressure
gauge pressure; liquid — 700 kPa to 70000 kPa · CMC 0,02 %
CMC for the field of measured quantity: Pressure
Comparison with a standard piston pressure gauge PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43
5 Thermocouples Calibration – temperature
20 °C to 1000 °C · CMC 2,4 °C 1000 °C to 1400 °C · CMC 4,5 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermocouple PPo TŽ-VA -11/45
6 Resistance thermometers Calibration – temperature
-20 °C to 200 °C · CMC 0,5 °C 200 °C to 450 °C · CMC 0,7 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer PPo TŽ-VA -11/46
7 Radiation thermometers Calibration – temperature
30 °C to 500 °C · CMC 4,0 °C 500 °C to 1400 °C · CMC 6,0 °C 1400 °C to 1500 °C · CMC 6,5 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard radiation thermometer PPo TŽ-VA -11/48
8 Electronic thermometers Calibration – temperature
-20 °C to 200 °C · CMC 0,6 °C 200 °C to 450 °C · CMC 0,8 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer PPo TŽ-VA -11/49
9 Electronic thermometers Calibration – temperature
450 °C to 1000 °C · CMC 2,9 °C 1000 °C to 1200 °C · CMC 5,2 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermoelectric thermometer PPo TŽ-VA -11/49
10 Temperature measuring instruments of process equipment Calibration – temperature
0 °C to 400 °C · CMC 2,0 °C 400 °C to 1200 °C · CMC 6,0 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard digital thermometer PPo TŽ-VA -11/50