{"lab":{"_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","address":"Průmyslová 1000, Staré Město, 739 61 Třinec","categories":["metrology"],"city":"Třinec","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[18.6472288,49.6881413]},"map_coord":[49.6881413,18.6472288],"map_geo":"cai-mapa","methods_count":10,"name":"TŘINECKÉ ŽELEZÁRNY, a. s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów pomiarowych w dziedzinach: ciśnienie i temperatura, w zakresie określonym w załączniku do świadectwa.","search_text":"třinecké železárny, a. s. průmyslová 1000, staré město, 739 61 třinec 2331","source_page_url":"https://www.cai.cz/?subjekt=2331-trinecke-zelezarny-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"24-04-2028","website":"www.trz.cz","certificate_date":"24.07.2026","certificate_no":"358/2026","certificate_replaces":"189/2025 z 22.04.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów pomiarowych w dziedzinach: ciśnienie i temperatura, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of measuring instruments in the fields of pressure and temperature, to the extent specified in the appendix to this Certificate.","zh":"压力和温度领域测量仪器的校准，范围见本证书附件。","cs":"Kalibrace měřidel v oborech tlak a teplota, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"KMS3 - Ośrodek Kontroli Metrologicznej jednostki VA","lab_division_cs":"KMS3 - Kontrolní metrologické středisko útvaru VA","lab_division_en":"KMS3 - Metrological Inspection Centre of the VA unit","lab_division_zh":"KMS3 - VA 部门计量检验中心","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"f7ca082530d98e6fabcc572890c49040c3dfc43d3696b0b1e3eff572f811ca1f","source_pdf_url":"https://www.cai.cz/OA/pdf/358_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"97bb1a77d3bf82a5f98b51c8","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia z elektrycznym sygnałem wyjściowym","test_object_en":"Deformation and digital pressure gauges, pressure transducers with electrical output signal","test_object_zh":"弹性式和数字式压力表、带电输出信号的压力变送器","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku s elektrickým výstupním signálem","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"nadciśnienie; gaz","range":"od -100 kPa do -70 kPa","cmc":"60 Pa"},{"name":"nadciśnienie; gaz","range":"od -70 kPa do -7,5 kPa","cmc":"18 Pa"},{"name":"nadciśnienie; gaz","range":"od -7,5 kPa do 0 kPa","cmc":"4 Pa"},{"name":"nadciśnienie; gaz","range":"od 0 kPa do 7,5 kPa","cmc":"4 Pa"},{"name":"nadciśnienie; gaz","range":"od 7,5 kPa do 70 kPa","cmc":"18 Pa"},{"name":"nadciśnienie; gaz","range":"od 70 kPa do 600 kPa","cmc":"60 Pa"},{"name":"nadciśnienie; gaz","range":"od 600 kPa do 7000 kPa","cmc":"0,01 %"}],"parameters_en":[{"name":"gauge pressure; gas","range":"-100 kPa to -70 kPa","cmc":"60 Pa"},{"name":"gauge pressure; gas","range":"-70 kPa to -7,5 kPa","cmc":"18 Pa"},{"name":"gauge pressure; gas","range":"-7,5 kPa to 0 kPa","cmc":"4 Pa"},{"name":"gauge pressure; gas","range":"0 kPa to 7,5 kPa","cmc":"4 Pa"},{"name":"gauge pressure; gas","range":"7,5 kPa to 70 kPa","cmc":"18 Pa"},{"name":"gauge pressure; gas","range":"70 kPa to 600 kPa","cmc":"60 Pa"},{"name":"gauge pressure; gas","range":"600 kPa to 7000 kPa","cmc":"0,01 %"}],"parameters_zh":[{"name":"表压；气体","range":"-100 kPa 至 -70 kPa","cmc":"60 Pa"},{"name":"表压；气体","range":"-70 kPa 至 -7,5 kPa","cmc":"18 Pa"},{"name":"表压；气体","range":"-7,5 kPa 至 0 kPa","cmc":"4 Pa"},{"name":"表压；气体","range":"0 kPa 至 7,5 kPa","cmc":"4 Pa"},{"name":"表压；气体","range":"7,5 kPa 至 70 kPa","cmc":"18 Pa"},{"name":"表压；气体","range":"70 kPa 至 600 kPa","cmc":"60 Pa"},{"name":"表压；气体","range":"600 kPa 至 7000 kPa","cmc":"0,01 %"}],"parameters_cs":[{"name":"přetlak; plyn","range":"-100 kPa až -70 kPa","cmc":"60 Pa"},{"name":"přetlak; plyn","range":"-70 kPa až -7,5 kPa","cmc":"18 Pa"},{"name":"přetlak; plyn","range":"-7,5 kPa až 0 kPa","cmc":"4 Pa"},{"name":"přetlak; plyn","range":"0 kPa až 7,5 kPa","cmc":"4 Pa"},{"name":"přetlak; plyn","range":"7,5 kPa až 70 kPa","cmc":"18 Pa"},{"name":"přetlak; plyn","range":"70 kPa až 600 kPa","cmc":"60 Pa"},{"name":"přetlak; plyn","range":"600 kPa až 7000 kPa","cmc":"0,01 %"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a standard digital pressure gauge","technique_zh":"与标准数字压力表比较","technique_cs":"Porovnání s etalonovým číslicovým tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a standard digital pressure gauge"],"techniques_zh":["与标准数字压力表比较"],"techniques_cs":["Porovnání s etalonovým číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nnadciśnienie; gaz od -100 kPa do -70 kPa CMC 60 Pa\nnadciśnienie; gaz od -70 kPa do -7,5 kPa CMC 18 Pa\nnadciśnienie; gaz od -7,5 kPa do 0 kPa CMC 4 Pa\nnadciśnienie; gaz od 0 kPa do 7,5 kPa CMC 4 Pa\nnadciśnienie; gaz od 7,5 kPa do 70 kPa CMC 18 Pa\nnadciśnienie; gaz od 70 kPa do 600 kPa CMC 60 Pa\nnadciśnienie; gaz od 600 kPa do 7000 kPa CMC 0,01 %\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","norm_bases":["PPo TŽ-VA -11/41","PPo TŽ-VA -11/42","PPo TŽ-VA -11/43"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia z elektrycznym sygnałem wyjściowym Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym nadciśnienie; gaz od -100 kPa do -70 kPa CMC 60 Pa nadciśnienie; gaz od -70 kPa do -7,5 kPa CMC 18 Pa nadciśnienie; gaz od -7,5 kPa do 0 kPa CMC 4 Pa nadciśnienie; gaz od 0 kPa do 7,5 kPa CMC 4 Pa nadciśnienie; gaz od 7,5 kPa do 70 kPa CMC 18 Pa nadciśnienie; gaz od 70 kPa do 600 kPa CMC 60 Pa nadciśnienie; gaz od 600 kPa do 7000 kPa CMC 0,01 % Deformační a číslicové tlakoměry, převodníky tlaku s elektrickým výstupním signálem Kalibrace – tlak Porovnání s etalonovým číslicovým tlakoměrem přetlak; plyn -100 kPa až -70 kPa CMC 60 Pa přetlak; plyn -70 kPa až -7,5 kPa CMC 18 Pa přetlak; plyn -7,5 kPa až 0 kPa CMC 4 Pa přetlak; plyn 0 kPa až 7,5 kPa CMC 4 Pa přetlak; plyn 7,5 kPa až 70 kPa CMC 18 Pa přetlak; plyn 70 kPa až 600 kPa CMC 60 Pa přetlak; plyn 600 kPa až 7000 kPa CMC 0,01 % PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia z elektrycznym sygnalem wyjsciowym Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym nadcisnienie; gaz od -100 kPa do -70 kPa CMC 60 Pa nadcisnienie; gaz od -70 kPa do -7,5 kPa CMC 18 Pa nadcisnienie; gaz od -7,5 kPa do 0 kPa CMC 4 Pa nadcisnienie; gaz od 0 kPa do 7,5 kPa CMC 4 Pa nadcisnienie; gaz od 7,5 kPa do 70 kPa CMC 18 Pa nadcisnienie; gaz od 70 kPa do 600 kPa CMC 60 Pa nadcisnienie; gaz od 600 kPa do 7000 kPa CMC 0,01 % Deformacni a cislicove tlakomery, prevodniky tlaku s elektrickym vystupnim signalem Kalibrace – tlak Porovnani s etalonovym cislicovym tlakomerem pretlak; plyn -100 kPa az -70 kPa CMC 60 Pa pretlak; plyn -70 kPa az -7,5 kPa CMC 18 Pa pretlak; plyn -7,5 kPa az 0 kPa CMC 4 Pa pretlak; plyn 0 kPa az 7,5 kPa CMC 4 Pa pretlak; plyn 7,5 kPa az 70 kPa CMC 18 Pa pretlak; plyn 70 kPa az 600 kPa CMC 60 Pa pretlak; plyn 600 kPa az 7000 kPa CMC 0,01 % PPo TZ-VA -11/41, PPo TZ-VA -11/42, PPo TZ-VA -11/43","search_en":"Deformation and digital pressure gauges, pressure transducers with electrical output signal Calibration – pressure Comparison with a standard digital pressure gauge gauge pressure; gas -100 kPa to -70 kPa CMC 60 Pa gauge pressure; gas -70 kPa to -7,5 kPa CMC 18 Pa gauge pressure; gas -7,5 kPa to 0 kPa CMC 4 Pa gauge pressure; gas 0 kPa to 7,5 kPa CMC 4 Pa gauge pressure; gas 7,5 kPa to 70 kPa CMC 18 Pa gauge pressure; gas 70 kPa to 600 kPa CMC 60 Pa gauge pressure; gas 600 kPa to 7000 kPa CMC 0,01 % PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","search_zh":"弹性式和数字式压力表、带电输出信号的压力变送器 校准 – 压力 与标准数字压力表比较 表压；气体 -100 kPa 至 -70 kPa CMC 60 Pa 表压；气体 -70 kPa 至 -7,5 kPa CMC 18 Pa 表压；气体 -7,5 kPa 至 0 kPa CMC 4 Pa 表压；气体 0 kPa 至 7,5 kPa CMC 4 Pa 表压；气体 7,5 kPa 至 70 kPa CMC 18 Pa 表压；气体 70 kPa 至 600 kPa CMC 60 Pa 表压；气体 600 kPa 至 7000 kPa CMC 0,01 % PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2fcb3edad761bbb734055107","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"2","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia z elektrycznym sygnałem wyjściowym","test_object_en":"Deformation and digital pressure gauges, pressure transducers with electrical output signal","test_object_zh":"弹性式和数字式压力表、带电输出信号的压力变送器","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku s elektrickým výstupním signálem","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"ciśnienie bezwzględne; gaz","range":"od 0 kPa do 600 kPa","cmc":"60 Pa"},{"name":"ciśnienie bezwzględne; gaz","range":"od 600 kPa do 7000 kPa","cmc":"0,01 %"}],"parameters_en":[{"name":"absolute pressure; gas","range":"0 kPa to 600 kPa","cmc":"60 Pa"},{"name":"absolute pressure; gas","range":"600 kPa to 7000 kPa","cmc":"0,01 %"}],"parameters_zh":[{"name":"绝对压力；气体","range":"0 kPa 至 600 kPa","cmc":"60 Pa"},{"name":"绝对压力；气体","range":"600 kPa 至 7000 kPa","cmc":"0,01 %"}],"parameters_cs":[{"name":"absolutní tlak; plyn","range":"0 kPa až 600 kPa","cmc":"60 Pa"},{"name":"absolutní tlak; plyn","range":"600 kPa až 7000 kPa","cmc":"0,01 %"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a standard digital pressure gauge","technique_zh":"与标准数字压力表比较","technique_cs":"Porovnání s etalonovým číslicovým tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a standard digital pressure gauge"],"techniques_zh":["与标准数字压力表比较"],"techniques_cs":["Porovnání s etalonovým číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nciśnienie bezwzględne; gaz od 0 kPa do 600 kPa CMC 60 Pa\nciśnienie bezwzględne; gaz od 600 kPa do 7000 kPa CMC 0,01 %\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","norm_bases":["PPo TŽ-VA -11/41","PPo TŽ-VA -11/42","PPo TŽ-VA -11/43"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia z elektrycznym sygnałem wyjściowym Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym ciśnienie bezwzględne; gaz od 0 kPa do 600 kPa CMC 60 Pa ciśnienie bezwzględne; gaz od 600 kPa do 7000 kPa CMC 0,01 % Deformační a číslicové tlakoměry, převodníky tlaku s elektrickým výstupním signálem Kalibrace – tlak Porovnání s etalonovým číslicovým tlakoměrem absolutní tlak; plyn 0 kPa až 600 kPa CMC 60 Pa absolutní tlak; plyn 600 kPa až 7000 kPa CMC 0,01 % PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia z elektrycznym sygnalem wyjsciowym Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym cisnienie bezwzgledne; gaz od 0 kPa do 600 kPa CMC 60 Pa cisnienie bezwzgledne; gaz od 600 kPa do 7000 kPa CMC 0,01 % Deformacni a cislicove tlakomery, prevodniky tlaku s elektrickym vystupnim signalem Kalibrace – tlak Porovnani s etalonovym cislicovym tlakomerem absolutni tlak; plyn 0 kPa az 600 kPa CMC 60 Pa absolutni tlak; plyn 600 kPa az 7000 kPa CMC 0,01 % PPo TZ-VA -11/41, PPo TZ-VA -11/42, PPo TZ-VA -11/43","search_en":"Deformation and digital pressure gauges, pressure transducers with electrical output signal Calibration – pressure Comparison with a standard digital pressure gauge absolute pressure; gas 0 kPa to 600 kPa CMC 60 Pa absolute pressure; gas 600 kPa to 7000 kPa CMC 0,01 % PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","search_zh":"弹性式和数字式压力表、带电输出信号的压力变送器 校准 – 压力 与标准数字压力表比较 绝对压力；气体 0 kPa 至 600 kPa CMC 60 Pa 绝对压力；气体 600 kPa 至 7000 kPa CMC 0,01 % PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14fd713785f5f1afb52f3113","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"3","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia z elektrycznym sygnałem wyjściowym","test_object_en":"Deformation and digital pressure gauges, pressure transducers with electrical output signal","test_object_zh":"弹性式和数字式压力表、带电输出信号的压力变送器","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku s elektrickým výstupním signálem","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"nadciśnienie; ciecz","range":"od 0 kPa do 100 kPa","cmc":"1800 Pa"},{"name":"nadciśnienie; ciecz","range":"od 100 kPa do 700 kPa","cmc":"300 Pa"}],"parameters_en":[{"name":"gauge pressure; liquid","range":"0 kPa to 100 kPa","cmc":"1800 Pa"},{"name":"gauge pressure; liquid","range":"100 kPa to 700 kPa","cmc":"300 Pa"}],"parameters_zh":[{"name":"表压；液体","range":"0 kPa 至 100 kPa","cmc":"1800 Pa"},{"name":"表压；液体","range":"100 kPa 至 700 kPa","cmc":"300 Pa"}],"parameters_cs":[{"name":"přetlak; kapalina","range":"0 kPa až 100 kPa","cmc":"1800 Pa"},{"name":"přetlak; kapalina","range":"100 kPa až 700 kPa","cmc":"300 Pa"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a standard digital pressure gauge","technique_zh":"与标准数字压力表比较","technique_cs":"Porovnání s etalonovým číslicovým tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a standard digital pressure gauge"],"techniques_zh":["与标准数字压力表比较"],"techniques_cs":["Porovnání s etalonovým číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nnadciśnienie; ciecz od 0 kPa do 100 kPa CMC 1800 Pa\nnadciśnienie; ciecz od 100 kPa do 700 kPa CMC 300 Pa\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","norm_bases":["PPo TŽ-VA -11/41","PPo TŽ-VA -11/42","PPo TŽ-VA -11/43"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia z elektrycznym sygnałem wyjściowym Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym nadciśnienie; ciecz od 0 kPa do 100 kPa CMC 1800 Pa nadciśnienie; ciecz od 100 kPa do 700 kPa CMC 300 Pa Deformační a číslicové tlakoměry, převodníky tlaku s elektrickým výstupním signálem Kalibrace – tlak Porovnání s etalonovým číslicovým tlakoměrem přetlak; kapalina 0 kPa až 100 kPa CMC 1800 Pa přetlak; kapalina 100 kPa až 700 kPa CMC 300 Pa PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia z elektrycznym sygnalem wyjsciowym Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym nadcisnienie; ciecz od 0 kPa do 100 kPa CMC 1800 Pa nadcisnienie; ciecz od 100 kPa do 700 kPa CMC 300 Pa Deformacni a cislicove tlakomery, prevodniky tlaku s elektrickym vystupnim signalem Kalibrace – tlak Porovnani s etalonovym cislicovym tlakomerem pretlak; kapalina 0 kPa az 100 kPa CMC 1800 Pa pretlak; kapalina 100 kPa az 700 kPa CMC 300 Pa PPo TZ-VA -11/41, PPo TZ-VA -11/42, PPo TZ-VA -11/43","search_en":"Deformation and digital pressure gauges, pressure transducers with electrical output signal Calibration – pressure Comparison with a standard digital pressure gauge gauge pressure; liquid 0 kPa to 100 kPa CMC 1800 Pa gauge pressure; liquid 100 kPa to 700 kPa CMC 300 Pa PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","search_zh":"弹性式和数字式压力表、带电输出信号的压力变送器 校准 – 压力 与标准数字压力表比较 表压；液体 0 kPa 至 100 kPa CMC 1800 Pa 表压；液体 100 kPa 至 700 kPa CMC 300 Pa PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e4f1d1babf920a998625b4c3","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"3","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia z elektrycznym sygnałem wyjściowym","test_object_en":"Deformation and digital pressure gauges, pressure transducers with electrical output signal","test_object_zh":"弹性式和数字式压力表、带电输出信号的压力变送器","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku s elektrickým výstupním signálem","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"nadciśnienie; ciecz","range":"od 700 kPa do 70000 kPa","cmc":"0,02 %"}],"parameters_en":[{"name":"gauge pressure; liquid","range":"700 kPa to 70000 kPa","cmc":"0,02 %"}],"parameters_zh":[{"name":"表压；液体","range":"700 kPa 至 70000 kPa","cmc":"0,02 %"}],"parameters_cs":[{"name":"přetlak; kapalina","range":"700 kPa až 70000 kPa","cmc":"0,02 %"}],"technique":"Porównanie z wzorcowym manometrem tłokowym","technique_en":"Comparison with a standard piston pressure gauge","technique_zh":"与标准活塞式压力计比较","technique_cs":"Porovnání s etalonovým pístovým tlakoměrem","techniques":["Porównanie z wzorcowym manometrem tłokowym"],"techniques_en":["Comparison with a standard piston pressure gauge"],"techniques_zh":["与标准活塞式压力计比较"],"techniques_cs":["Porovnání s etalonovým pístovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nnadciśnienie; ciecz od 700 kPa do 70000 kPa CMC 0,02 %\nPorównanie z wzorcowym manometrem tłokowym","reference":"PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","norm_bases":["PPo TŽ-VA -11/41","PPo TŽ-VA -11/42","PPo TŽ-VA -11/43"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia z elektrycznym sygnałem wyjściowym Wzorcowanie – ciśnienie Porównanie z wzorcowym manometrem tłokowym nadciśnienie; ciecz od 700 kPa do 70000 kPa CMC 0,02 % Deformační a číslicové tlakoměry, převodníky tlaku s elektrickým výstupním signálem Kalibrace – tlak Porovnání s etalonovým pístovým tlakoměrem přetlak; kapalina 700 kPa až 70000 kPa CMC 0,02 % PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia z elektrycznym sygnalem wyjsciowym Wzorcowanie – cisnienie Porownanie z wzorcowym manometrem tlokowym nadcisnienie; ciecz od 700 kPa do 70000 kPa CMC 0,02 % Deformacni a cislicove tlakomery, prevodniky tlaku s elektrickym vystupnim signalem Kalibrace – tlak Porovnani s etalonovym pistovym tlakomerem pretlak; kapalina 700 kPa az 70000 kPa CMC 0,02 % PPo TZ-VA -11/41, PPo TZ-VA -11/42, PPo TZ-VA -11/43","search_en":"Deformation and digital pressure gauges, pressure transducers with electrical output signal Calibration – pressure Comparison with a standard piston pressure gauge gauge pressure; liquid 700 kPa to 70000 kPa CMC 0,02 % PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","search_zh":"弹性式和数字式压力表、带电输出信号的压力变送器 校准 – 压力 与标准活塞式压力计比较 表压；液体 700 kPa 至 70000 kPa CMC 0,02 % PPo TŽ-VA -11/41, PPo TŽ-VA -11/42, PPo TŽ-VA -11/43","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aac459cafcdf076cd9e923f9","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"1","test_object":"Termopary","test_object_en":"Thermocouples","test_object_zh":"热电偶","test_object_cs":"Termoelektrické články","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 20 °C do 1000 °C","cmc":"2,4 °C"},{"name":"","range":"od 1000 °C do 1400 °C","cmc":"4,5 °C"}],"parameters_en":[{"name":"","range":"20 °C to 1000 °C","cmc":"2,4 °C"},{"name":"","range":"1000 °C to 1400 °C","cmc":"4,5 °C"}],"parameters_zh":[{"name":"","range":"20 °C 至 1000 °C","cmc":"2,4 °C"},{"name":"","range":"1000 °C 至 1400 °C","cmc":"4,5 °C"}],"parameters_cs":[{"name":"","range":"20 °C až 1000 °C","cmc":"2,4 °C"},{"name":"","range":"1000 °C až 1400 °C","cmc":"4,5 °C"}],"technique":"Porównanie z termoparą wzorcową","technique_en":"Comparison with a standard thermocouple","technique_zh":"与标准热电偶比较","technique_cs":"Porovnání s etalonovým termoelektrickým článkem","techniques":["Porównanie z termoparą wzorcową"],"techniques_en":["Comparison with a standard thermocouple"],"techniques_zh":["与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým článkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 20 °C do 1000 °C CMC 2,4 °C\nod 1000 °C do 1400 °C CMC 4,5 °C\nPorównanie z termoparą wzorcową","reference":"PPo TŽ-VA -11/45","norm_bases":["PPo TŽ-VA -11/45"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopary Wzorcowanie – temperatura Porównanie z termoparą wzorcową od 20 °C do 1000 °C CMC 2,4 °C od 1000 °C do 1400 °C CMC 4,5 °C Termoelektrické články Kalibrace – teplota Porovnání s etalonovým termoelektrickým článkem 20 °C až 1000 °C CMC 2,4 °C 1000 °C až 1400 °C CMC 4,5 °C PPo TŽ-VA -11/45 Termopary Wzorcowanie – temperatura Porownanie z termopara wzorcowa od 20 °C do 1000 °C CMC 2,4 °C od 1000 °C do 1400 °C CMC 4,5 °C Termoelektricke clanky Kalibrace – teplota Porovnani s etalonovym termoelektrickym clankem 20 °C az 1000 °C CMC 2,4 °C 1000 °C az 1400 °C CMC 4,5 °C PPo TZ-VA -11/45","search_en":"Thermocouples Calibration – temperature Comparison with a standard thermocouple 20 °C to 1000 °C CMC 2,4 °C 1000 °C to 1400 °C CMC 4,5 °C PPo TŽ-VA -11/45","search_zh":"热电偶 校准 – 温度 与标准热电偶比较 20 °C 至 1000 °C CMC 2,4 °C 1000 °C 至 1400 °C CMC 4,5 °C PPo TŽ-VA -11/45","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"769d1baa00582fb6ed8888e6","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"2","test_object":"Termometry rezystancyjne","test_object_en":"Resistance thermometers","test_object_zh":"电阻温度计","test_object_cs":"Odporové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -20 °C do 200 °C","cmc":"0,5 °C"},{"name":"","range":"od 200 °C do 450 °C","cmc":"0,7 °C"}],"parameters_en":[{"name":"","range":"-20 °C to 200 °C","cmc":"0,5 °C"},{"name":"","range":"200 °C to 450 °C","cmc":"0,7 °C"}],"parameters_zh":[{"name":"","range":"-20 °C 至 200 °C","cmc":"0,5 °C"},{"name":"","range":"200 °C 至 450 °C","cmc":"0,7 °C"}],"parameters_cs":[{"name":"","range":"-20 °C až 200 °C","cmc":"0,5 °C"},{"name":"","range":"200 °C až 450 °C","cmc":"0,7 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym","technique_en":"Comparison with a standard resistance thermometer","technique_zh":"与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym"],"techniques_en":["Comparison with a standard resistance thermometer"],"techniques_zh":["与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -20 °C do 200 °C CMC 0,5 °C\nod 200 °C do 450 °C CMC 0,7 °C\nPorównanie z wzorcowym termometrem rezystancyjnym","reference":"PPo TŽ-VA -11/46","norm_bases":["PPo TŽ-VA -11/46"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry rezystancyjne Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym od -20 °C do 200 °C CMC 0,5 °C od 200 °C do 450 °C CMC 0,7 °C Odporové teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem -20 °C až 200 °C CMC 0,5 °C 200 °C až 450 °C CMC 0,7 °C PPo TŽ-VA -11/46 Termometry rezystancyjne Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym od -20 °C do 200 °C CMC 0,5 °C od 200 °C do 450 °C CMC 0,7 °C Odporove teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem -20 °C az 200 °C CMC 0,5 °C 200 °C az 450 °C CMC 0,7 °C PPo TZ-VA -11/46","search_en":"Resistance thermometers Calibration – temperature Comparison with a standard resistance thermometer -20 °C to 200 °C CMC 0,5 °C 200 °C to 450 °C CMC 0,7 °C PPo TŽ-VA -11/46","search_zh":"电阻温度计 校准 – 温度 与标准电阻温度计比较 -20 °C 至 200 °C CMC 0,5 °C 200 °C 至 450 °C CMC 0,7 °C PPo TŽ-VA -11/46","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ef6be6d314fda52d2317588f","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"3","test_object":"Termometry radiacyjne","test_object_en":"Radiation thermometers","test_object_zh":"辐射温度计","test_object_cs":"Radiační teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 30 °C do 500 °C","cmc":"4,0 °C"},{"name":"","range":"od 500 °C do 1400 °C","cmc":"6,0 °C"},{"name":"","range":"od 1400 °C do 1500 °C","cmc":"6,5 °C"}],"parameters_en":[{"name":"","range":"30 °C to 500 °C","cmc":"4,0 °C"},{"name":"","range":"500 °C to 1400 °C","cmc":"6,0 °C"},{"name":"","range":"1400 °C to 1500 °C","cmc":"6,5 °C"}],"parameters_zh":[{"name":"","range":"30 °C 至 500 °C","cmc":"4,0 °C"},{"name":"","range":"500 °C 至 1400 °C","cmc":"6,0 °C"},{"name":"","range":"1400 °C 至 1500 °C","cmc":"6,5 °C"}],"parameters_cs":[{"name":"","range":"30 °C až 500 °C","cmc":"4,0 °C"},{"name":"","range":"500 °C až 1400 °C","cmc":"6,0 °C"},{"name":"","range":"1400 °C až 1500 °C","cmc":"6,5 °C"}],"technique":"Porównanie z wzorcowym termometrem radiacyjnym","technique_en":"Comparison with a standard radiation thermometer","technique_zh":"与标准辐射温度计比较","technique_cs":"Porovnání s etalonovým radiačním teploměrem","techniques":["Porównanie z wzorcowym termometrem radiacyjnym"],"techniques_en":["Comparison with a standard radiation thermometer"],"techniques_zh":["与标准辐射温度计比较"],"techniques_cs":["Porovnání s etalonovým radiačním teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 30 °C do 500 °C CMC 4,0 °C\nod 500 °C do 1400 °C CMC 6,0 °C\nod 1400 °C do 1500 °C CMC 6,5 °C\nPorównanie z wzorcowym termometrem radiacyjnym","reference":"PPo TŽ-VA -11/48","norm_bases":["PPo TŽ-VA -11/48"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry radiacyjne Wzorcowanie – temperatura Porównanie z wzorcowym termometrem radiacyjnym od 30 °C do 500 °C CMC 4,0 °C od 500 °C do 1400 °C CMC 6,0 °C od 1400 °C do 1500 °C CMC 6,5 °C Radiační teploměry Kalibrace – teplota Porovnání s etalonovým radiačním teploměrem 30 °C až 500 °C CMC 4,0 °C 500 °C až 1400 °C CMC 6,0 °C 1400 °C až 1500 °C CMC 6,5 °C PPo TŽ-VA -11/48 Termometry radiacyjne Wzorcowanie – temperatura Porownanie z wzorcowym termometrem radiacyjnym od 30 °C do 500 °C CMC 4,0 °C od 500 °C do 1400 °C CMC 6,0 °C od 1400 °C do 1500 °C CMC 6,5 °C Radiacni teplomery Kalibrace – teplota Porovnani s etalonovym radiacnim teplomerem 30 °C az 500 °C CMC 4,0 °C 500 °C az 1400 °C CMC 6,0 °C 1400 °C az 1500 °C CMC 6,5 °C PPo TZ-VA -11/48","search_en":"Radiation thermometers Calibration – temperature Comparison with a standard radiation thermometer 30 °C to 500 °C CMC 4,0 °C 500 °C to 1400 °C CMC 6,0 °C 1400 °C to 1500 °C CMC 6,5 °C PPo TŽ-VA -11/48","search_zh":"辐射温度计 校准 – 温度 与标准辐射温度计比较 30 °C 至 500 °C CMC 4,0 °C 500 °C 至 1400 °C CMC 6,0 °C 1400 °C 至 1500 °C CMC 6,5 °C PPo TŽ-VA -11/48","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"39abf4d442eea248a6ee5aa4","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"4","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -20 °C do 200 °C","cmc":"0,6 °C"},{"name":"","range":"od 200 °C do 450 °C","cmc":"0,8 °C"}],"parameters_en":[{"name":"","range":"-20 °C to 200 °C","cmc":"0,6 °C"},{"name":"","range":"200 °C to 450 °C","cmc":"0,8 °C"}],"parameters_zh":[{"name":"","range":"-20 °C 至 200 °C","cmc":"0,6 °C"},{"name":"","range":"200 °C 至 450 °C","cmc":"0,8 °C"}],"parameters_cs":[{"name":"","range":"-20 °C až 200 °C","cmc":"0,6 °C"},{"name":"","range":"200 °C až 450 °C","cmc":"0,8 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym","technique_en":"Comparison with a standard resistance thermometer","technique_zh":"与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym"],"techniques_en":["Comparison with a standard resistance thermometer"],"techniques_zh":["与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -20 °C do 200 °C CMC 0,6 °C\nod 200 °C do 450 °C CMC 0,8 °C\nPorównanie z wzorcowym termometrem rezystancyjnym","reference":"PPo TŽ-VA -11/49","norm_bases":["PPo TŽ-VA -11/49"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym od -20 °C do 200 °C CMC 0,6 °C od 200 °C do 450 °C CMC 0,8 °C Elektronické teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem -20 °C až 200 °C CMC 0,6 °C 200 °C až 450 °C CMC 0,8 °C PPo TŽ-VA -11/49 Termometry elektroniczne Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym od -20 °C do 200 °C CMC 0,6 °C od 200 °C do 450 °C CMC 0,8 °C Elektronicke teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem -20 °C az 200 °C CMC 0,6 °C 200 °C az 450 °C CMC 0,8 °C PPo TZ-VA -11/49","search_en":"Electronic thermometers Calibration – temperature Comparison with a standard resistance thermometer -20 °C to 200 °C CMC 0,6 °C 200 °C to 450 °C CMC 0,8 °C PPo TŽ-VA -11/49","search_zh":"电子温度计 校准 – 温度 与标准电阻温度计比较 -20 °C 至 200 °C CMC 0,6 °C 200 °C 至 450 °C CMC 0,8 °C PPo TŽ-VA -11/49","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0814c646f92bae965c3c3706","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"4","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 450 °C do 1000 °C","cmc":"2,9 °C"},{"name":"","range":"od 1000 °C do 1200 °C","cmc":"5,2 °C"}],"parameters_en":[{"name":"","range":"450 °C to 1000 °C","cmc":"2,9 °C"},{"name":"","range":"1000 °C to 1200 °C","cmc":"5,2 °C"}],"parameters_zh":[{"name":"","range":"450 °C 至 1000 °C","cmc":"2,9 °C"},{"name":"","range":"1000 °C 至 1200 °C","cmc":"5,2 °C"}],"parameters_cs":[{"name":"","range":"450 °C až 1000 °C","cmc":"2,9 °C"},{"name":"","range":"1000 °C až 1200 °C","cmc":"5,2 °C"}],"technique":"Porównanie z wzorcowym termometrem termoelektrycznym","technique_en":"Comparison with a standard thermoelectric thermometer","technique_zh":"与标准热电温度计比较","technique_cs":"Porovnání s etalonovým termoelektrickým teploměrem","techniques":["Porównanie z wzorcowym termometrem termoelektrycznym"],"techniques_en":["Comparison with a standard thermoelectric thermometer"],"techniques_zh":["与标准热电温度计比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 450 °C do 1000 °C CMC 2,9 °C\nod 1000 °C do 1200 °C CMC 5,2 °C\nPorównanie z wzorcowym termometrem termoelektrycznym","reference":"PPo TŽ-VA -11/49","norm_bases":["PPo TŽ-VA -11/49"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie z wzorcowym termometrem termoelektrycznym od 450 °C do 1000 °C CMC 2,9 °C od 1000 °C do 1200 °C CMC 5,2 °C Elektronické teploměry Kalibrace – teplota Porovnání s etalonovým termoelektrickým teploměrem 450 °C až 1000 °C CMC 2,9 °C 1000 °C až 1200 °C CMC 5,2 °C PPo TŽ-VA -11/49 Termometry elektroniczne Wzorcowanie – temperatura Porownanie z wzorcowym termometrem termoelektrycznym od 450 °C do 1000 °C CMC 2,9 °C od 1000 °C do 1200 °C CMC 5,2 °C Elektronicke teplomery Kalibrace – teplota Porovnani s etalonovym termoelektrickym teplomerem 450 °C az 1000 °C CMC 2,9 °C 1000 °C az 1200 °C CMC 5,2 °C PPo TZ-VA -11/49","search_en":"Electronic thermometers Calibration – temperature Comparison with a standard thermoelectric thermometer 450 °C to 1000 °C CMC 2,9 °C 1000 °C to 1200 °C CMC 5,2 °C PPo TŽ-VA -11/49","search_zh":"电子温度计 校准 – 温度 与标准热电温度计比较 450 °C 至 1000 °C CMC 2,9 °C 1000 °C 至 1200 °C CMC 5,2 °C PPo TŽ-VA -11/49","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e2b5bd7078fea4bf379e28f0","lab_id":"6ade8b36ff06824761708118","country":"CZ","accr_number":"2331","accr_body":"ČIA","row_label":"5","test_object":"Przyrządy do pomiaru temperatury urządzeń technologicznych","test_object_en":"Temperature measuring instruments of process equipment","test_object_zh":"工艺设备温度测量仪表","test_object_cs":"Měřidla teploty technologických zařízení","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 400 °C","cmc":"2,0 °C"},{"name":"","range":"od 400 °C do 1200 °C","cmc":"6,0 °C"}],"parameters_en":[{"name":"","range":"0 °C to 400 °C","cmc":"2,0 °C"},{"name":"","range":"400 °C to 1200 °C","cmc":"6,0 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 400 °C","cmc":"2,0 °C"},{"name":"","range":"400 °C 至 1200 °C","cmc":"6,0 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 400 °C","cmc":"2,0 °C"},{"name":"","range":"400 °C až 1200 °C","cmc":"6,0 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym","technique_en":"Comparison with a standard digital thermometer","technique_zh":"与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem","techniques":["Porównanie z wzorcowym termometrem cyfrowym"],"techniques_en":["Comparison with a standard digital thermometer"],"techniques_zh":["与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 0 °C do 400 °C CMC 2,0 °C\nod 400 °C do 1200 °C CMC 6,0 °C\nPorównanie z wzorcowym termometrem cyfrowym","reference":"PPo TŽ-VA -11/50","norm_bases":["PPo TŽ-VA -11/50"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru temperatury urządzeń technologicznych Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym od 0 °C do 400 °C CMC 2,0 °C od 400 °C do 1200 °C CMC 6,0 °C Měřidla teploty technologických zařízení Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem 0 °C až 400 °C CMC 2,0 °C 400 °C až 1200 °C CMC 6,0 °C PPo TŽ-VA -11/50 Przyrzady do pomiaru temperatury urzadzen technologicznych Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym od 0 °C do 400 °C CMC 2,0 °C od 400 °C do 1200 °C CMC 6,0 °C Meridla teploty technologickych zarizeni Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem 0 °C az 400 °C CMC 2,0 °C 400 °C az 1200 °C CMC 6,0 °C PPo TZ-VA -11/50","search_en":"Temperature measuring instruments of process equipment Calibration – temperature Comparison with a standard digital thermometer 0 °C to 400 °C CMC 2,0 °C 400 °C to 1200 °C CMC 6,0 °C PPo TŽ-VA -11/50","search_zh":"工艺设备温度测量仪表 校准 – 温度 与标准数字温度计比较 0 °C 至 400 °C CMC 2,0 °C 400 °C 至 1200 °C CMC 6,0 °C PPo TŽ-VA -11/50","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}