🇨🇿 Všeobecná fakultní nemocnice v Praze PL

ČIA 2323 • Praha 2, Czech Republic • 4 calibration items

Metrology & calibration

Všeobecná fakultní nemocnice v Praze is a calibration laboratory accredited by ČIA under number 2323 (Praha 2, Czech Republic). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Glass and digital thermometers, Non-automatic weighing instruments, Piston pipettes (single- and multi-channel) and piston dispensers, Temperature measuring chains. Most frequently used calibration principles: Comparison with a digital standard thermometer, Comparison with a standard digital thermometer in a liquid bath, Gravimetric method.

At a glance

  • Accreditation number: ČIA 2323
  • Calibration items in scope: 4
  • Types of calibrated items: 4
  • Calibration principles used: 4
  • City: Praha 2, Czech Republic
  • Valid until: 08-09-2027
Accreditation number
2323
Accreditation body
ČIA
Address
Na Bojišti 1, 128 08 Praha 2
City
Praha 2, Czech Republic
Division
Ośrodek metrologiczny
Valid until
08-09-2027

What this laboratory calibrates (4)

Calibration principles (4)

Certificate information

Certificate date
08.09.2022

Accreditation scope — calibration items (4)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Piston pipettes (single- and multi-channel) and piston dispensers Calibration – volume, flow
5 µl to 10 µl · CMC 0,07 µl 10 µl to 100 µl · CMC 0,16 µl 100 µl to 200 µl · CMC 0,25 µl 200 µl to 1000 µl · CMC 1,2 µl 1000 µl to 5000 µl · CMC 5,8 µl
CMC for the field of measured quantity: Volume, flow
Gravimetric method KP-06-01
2 Non-automatic weighing instruments Calibration – mass
According to the weights used for calibration, Uᵢ can take the values: U(CMC) = ∑ Uᵢ — 1 mg to 10 kg · CMC U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg
CMC for the field of measured quantity: Mass
Loading with an F1 class standard weight KP-08-01
3 Glass and digital thermometers Calibration – temperature
-40 °C to -1 °C · CMC 0,06 °C -1 °C to 1 °C · CMC 0,05 °C 1 °C to 40 °C · CMC 0,07 °C 40 °C to 200 °C · CMC 0,10 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard digital thermometer in a liquid bath KP-03-01, KP-03-02
4 Temperature measuring chains Calibration – temperature
-40 °C to 50 °C · CMC 0,3 °C 50 °C to 120 °C · CMC 0,4 °C 120 °C to 180 °C · CMC 0,6 °C
CMC for the field of measured quantity: Temperature
Comparison with a digital standard thermometer KP-03-02

Reference standards (4)

KP-03-01
KP-03-02
KP-06-01
KP-08-01

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2323