{"lab":{"_id":"6ade8b36ff06824761708116","country":"CZ","accr_number":"2323","accr_body":"ČIA","address":"Na Bojišti 1, 128 08 Praha 2","categories":["metrology"],"city":"Praha 2","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.4273445,50.0731942]},"map_coord":[50.0731942,14.4273445],"map_geo":"cai-mapa","methods_count":4,"name":"Všeobecná fakultní nemocnice v Praze","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów do pomiaru masy, objętości i temperatury, w tym torów pomiarowych temperatury.","search_text":"všeobecná fakultní nemocnice v praze na bojišti 1, 128 08 praha 2 2323","source_page_url":"https://www.cai.cz/?subjekt=2323-vseobecna-fakultni-nemocnice-v-praze","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"08-09-2027","website":"www.vfn.cz","certificate_date":"08.09.2022","certificate_no":"439/2022","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów do pomiaru masy, objętości i temperatury, w tym torów pomiarowych temperatury.","en":"Calibration of instruments for measuring mass, volume and temperature, including temperature measuring chains.","zh":"质量、体积和温度测量仪器（包括温度测量链）的校准。","cs":"Kalibrace měřidel hmotnosti, objemu a teploty včetně měřicích řetězců teploty."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Ośrodek metrologiczny","lab_division_cs":"Metrologické středisko","lab_division_en":"Metrology Centre","lab_division_zh":"计量中心","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Przy wzorcowaniu poza stałą siedzibą podawana niepewność wzorcowania może ulec zmianie.","en":"When calibrating outside the permanent premises, the stated calibration uncertainty may be affected.","zh":"在固定场所以外进行校准时，所述校准不确定度可能受到影响。","cs":"Při kalibraci mimo stálé prostory je možné ovlivnění udávané nejistoty kalibrace."}],"source_lang":"cs","source_pdf_sha256":"76ac5e6c552ada6835273c3056e182ae3a686e743b781dd48e8fe023fe9c4fa2","source_pdf_url":"https://www.cai.cz/OA/pdf/P439_2022_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"f53f810de7e4b655a6b2197b","lab_id":"6ade8b36ff06824761708116","country":"CZ","accr_number":"2323","accr_body":"ČIA","row_label":"1","test_object":"Pipety tłokowe (jedno- i wielokanałowe) i dozowniki tłokowe","test_object_en":"Piston pipettes (single- and multi-channel) and piston dispensers","test_object_zh":"活塞式移液器（单道和多道）和活塞式分液器","test_object_cs":"Pístové pipety (jedno a více kanálové) a pístové dávkovače","methodology":"Wzorcowanie – objętość, przepływ","methodology_en":"Calibration – volume, flow","methodology_zh":"校准 – 体积、流量","methodology_cs":"Kalibrace – objem, průtok","parameters":[{"name":"","range":"od 5 µl do 10 µl","cmc":"0,07 µl"},{"name":"","range":"od 10 µl do 100 µl","cmc":"0,16 µl"},{"name":"","range":"od 100 µl do 200 µl","cmc":"0,25 µl"},{"name":"","range":"od 200 µl do 1000 µl","cmc":"1,2 µl"},{"name":"","range":"od 1000 µl do 5000 µl","cmc":"5,8 µl"}],"parameters_en":[{"name":"","range":"5 µl to 10 µl","cmc":"0,07 µl"},{"name":"","range":"10 µl to 100 µl","cmc":"0,16 µl"},{"name":"","range":"100 µl to 200 µl","cmc":"0,25 µl"},{"name":"","range":"200 µl to 1000 µl","cmc":"1,2 µl"},{"name":"","range":"1000 µl to 5000 µl","cmc":"5,8 µl"}],"parameters_zh":[{"name":"","range":"5 µl 至 10 µl","cmc":"0,07 µl"},{"name":"","range":"10 µl 至 100 µl","cmc":"0,16 µl"},{"name":"","range":"100 µl 至 200 µl","cmc":"0,25 µl"},{"name":"","range":"200 µl 至 1000 µl","cmc":"1,2 µl"},{"name":"","range":"1000 µl 至 5000 µl","cmc":"5,8 µl"}],"parameters_cs":[{"name":"","range":"5 µl až 10 µl","cmc":"0,07 µl"},{"name":"","range":"10 µl až 100 µl","cmc":"0,16 µl"},{"name":"","range":"100 µl až 200 µl","cmc":"0,25 µl"},{"name":"","range":"200 µl až 1000 µl","cmc":"1,2 µl"},{"name":"","range":"1000 µl až 5000 µl","cmc":"5,8 µl"}],"technique":"Metoda grawimetryczna","technique_en":"Gravimetric method","technique_zh":"重量法","technique_cs":"Gravimetrická metoda","techniques":["Metoda grawimetryczna"],"techniques_en":["Gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["Gravimetrická metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość, przepływ\nZakres:\nod 5 µl do 10 µl CMC 0,07 µl\nod 10 µl do 100 µl CMC 0,16 µl\nod 100 µl do 200 µl CMC 0,25 µl\nod 200 µl do 1000 µl CMC 1,2 µl\nod 1000 µl do 5000 µl CMC 5,8 µl\nMetoda grawimetryczna","reference":"KP-06-01","norm_bases":["KP-06-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość, przepływ","regulatory_area_en":"CMC for the field of measured quantity: Volume, flow","regulatory_area_zh":"被测量领域的CMC：体积、流量","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem, průtok","flexible":false,"flexibility":null,"outside_premises":false,"note":"Przy obliczaniu najmniejszej podawanej niepewności rozszerzonej uwzględniono także wpływ operatora.","note_en":"The influence of the operator was also taken into account when calculating the lowest stated expanded measurement uncertainty.","note_zh":"计算最小扩展测量不确定度时也考虑了操作者的影响。","note_cs":"Při výpočtu nejnižší udávané rozšířené nejistoty měření byl uvažován i vliv operátora.","search_text":"Pipety tłokowe (jedno- i wielokanałowe) i dozowniki tłokowe Wzorcowanie – objętość, przepływ Metoda grawimetryczna od 5 µl do 10 µl CMC 0,07 µl od 10 µl do 100 µl CMC 0,16 µl od 100 µl do 200 µl CMC 0,25 µl od 200 µl do 1000 µl CMC 1,2 µl od 1000 µl do 5000 µl CMC 5,8 µl Pístové pipety (jedno a více kanálové) a pístové dávkovače Kalibrace – objem, průtok Gravimetrická metoda 5 µl až 10 µl CMC 0,07 µl 10 µl až 100 µl CMC 0,16 µl 100 µl až 200 µl CMC 0,25 µl 200 µl až 1000 µl CMC 1,2 µl 1000 µl až 5000 µl CMC 5,8 µl KP-06-01 Pipety tlokowe (jedno- i wielokanalowe) i dozowniki tlokowe Wzorcowanie – objetosc, przeplyw Metoda grawimetryczna od 5 µl do 10 µl CMC 0,07 µl od 10 µl do 100 µl CMC 0,16 µl od 100 µl do 200 µl CMC 0,25 µl od 200 µl do 1000 µl CMC 1,2 µl od 1000 µl do 5000 µl CMC 5,8 µl Pistove pipety (jedno a vice kanalove) a pistove davkovace Kalibrace – objem, prutok Gravimetricka metoda 5 µl az 10 µl CMC 0,07 µl 10 µl az 100 µl CMC 0,16 µl 100 µl az 200 µl CMC 0,25 µl 200 µl az 1000 µl CMC 1,2 µl 1000 µl az 5000 µl CMC 5,8 µl KP-06-01","search_en":"Piston pipettes (single- and multi-channel) and piston dispensers Calibration – volume, flow Gravimetric method 5 µl to 10 µl CMC 0,07 µl 10 µl to 100 µl CMC 0,16 µl 100 µl to 200 µl CMC 0,25 µl 200 µl to 1000 µl CMC 1,2 µl 1000 µl to 5000 µl CMC 5,8 µl KP-06-01","search_zh":"活塞式移液器（单道和多道）和活塞式分液器 校准 – 体积、流量 重量法 5 µl 至 10 µl CMC 0,07 µl 10 µl 至 100 µl CMC 0,16 µl 100 µl 至 200 µl CMC 0,25 µl 200 µl 至 1000 µl CMC 1,2 µl 1000 µl 至 5000 µl CMC 5,8 µl KP-06-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dc12f6eada995bc3d108c463","lab_id":"6ade8b36ff06824761708116","country":"CZ","accr_number":"2323","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Non-automatic weighing instruments","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"W zależności od odważników użytych przy wzorcowaniu Uᵢ może przyjmować wartości: U(CMC) = ∑ Uᵢ","range":"od 1 mg do 10 kg","cmc":"U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg"}],"parameters_en":[{"name":"According to the weights used for calibration, Uᵢ can take the values: U(CMC) = ∑ Uᵢ","range":"1 mg to 10 kg","cmc":"U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg"}],"parameters_zh":[{"name":"根据校准所用砝码，Uᵢ 可取下列值：U(CMC) = ∑ Uᵢ","range":"1 mg 至 10 kg","cmc":"U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg"}],"parameters_cs":[{"name":"Podle závaží použitých při kalibraci může Uᵢ nabývat hodnot: U(CMC) = ∑ Uᵢ","range":"1 mg až 10 kg","cmc":"U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg"}],"technique":"Obciążenie odważnikiem wzorcowym klasy F1","technique_en":"Loading with an F1 class standard weight","technique_zh":"用 F1 级标准砝码加载","technique_cs":"Zatížení etalonovým závažím třídy F1","techniques":["Obciążenie odważnikiem wzorcowym klasy F1"],"techniques_en":["Loading with an F1 class standard weight"],"techniques_zh":["用 F1 级标准砝码加载"],"techniques_cs":["Zatížení etalonovým závažím třídy F1"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nW zależności od odważników użytych przy wzorcowaniu Uᵢ może przyjmować wartości: U(CMC) = ∑ Uᵢ od 1 mg do 10 kg CMC U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg\nObciążenie odważnikiem wzorcowym klasy F1","reference":"KP-08-01","norm_bases":["KP-08-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym klasy F1 W zależności od odważników użytych przy wzorcowaniu Uᵢ może przyjmować wartości: U(CMC) = ∑ Uᵢ od 1 mg do 10 kg CMC U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím třídy F1 Podle závaží použitých při kalibraci může Uᵢ nabývat hodnot: U(CMC) = ∑ Uᵢ 1 mg až 10 kg CMC U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg KP-08-01 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym klasy F1 W zaleznosci od odwaznikow uzytych przy wzorcowaniu Uᵢ moze przyjmowac wartosci: U(CMC) = ∑ Uᵢ od 1 mg do 10 kg CMC U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim tridy F1 Podle zavazi pouzitych pri kalibraci muze Uᵢ nabyvat hodnot: U(CMC) = ∑ Uᵢ 1 mg az 10 kg CMC U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg KP-08-01","search_en":"Non-automatic weighing instruments Calibration – mass Loading with an F1 class standard weight According to the weights used for calibration, Uᵢ can take the values: U(CMC) = ∑ Uᵢ 1 mg to 10 kg CMC U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg KP-08-01","search_zh":"非自动衡器 校准 – 质量 用 F1 级标准砝码加载 根据校准所用砝码，Uᵢ 可取下列值：U(CMC) = ∑ Uᵢ 1 mg 至 10 kg CMC U₁ (0,001 g) = 0,019 mg; U₂ (0,002 g) = 0,019 mg; U₃ (0,005 g) = 0,019 mg; U₄ (0,01 g) = 0,024 mg; U₅ (0,02 g) = 0,029 mg; U₆ (0,05 g) = 0,038 mg; U₇ (0,1 g) = 0,048 mg; U₈ (0,02 g) = 0,057 mg; U₉ (0,5 g) = 0,076 mg; U₁₀ (1 g) = 0,095 mg; U₁₁ (2 g) = 0,11 mg; U₁₂ (5 g) = 0,15 mg; U₁₃ (10 g) = 0,19 mg; U₁₄ (20 g) = 0,24 mg; U₁₅ (50 g) = 0,29 mg; U₁₆ (100 g) = 0,48 mg; U₁₇ (200 g) = 0,95 mg; U₁₈ (500 g) = 2,4 mg; U₁₉ (1000 g) = 4,8 mg; U₂₀ (2000 g) = 9,5 mg; U₂₁ (5000 g) = 24 mg; U₂₂ (10000 g) = 48 mg KP-08-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15d394e6117d94be451ff975","lab_id":"6ade8b36ff06824761708116","country":"CZ","accr_number":"2323","accr_body":"ČIA","row_label":"1","test_object":"Termometry szklane i cyfrowe","test_object_en":"Glass and digital thermometers","test_object_zh":"玻璃和数字温度计","test_object_cs":"Teploměry skleněné a digitální","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do -1 °C","cmc":"0,06 °C"},{"name":"","range":"od -1 °C do 1 °C","cmc":"0,05 °C"},{"name":"","range":"od 1 °C do 40 °C","cmc":"0,07 °C"},{"name":"","range":"od 40 °C do 200 °C","cmc":"0,10 °C"}],"parameters_en":[{"name":"","range":"-40 °C to -1 °C","cmc":"0,06 °C"},{"name":"","range":"-1 °C to 1 °C","cmc":"0,05 °C"},{"name":"","range":"1 °C to 40 °C","cmc":"0,07 °C"},{"name":"","range":"40 °C to 200 °C","cmc":"0,10 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 -1 °C","cmc":"0,06 °C"},{"name":"","range":"-1 °C 至 1 °C","cmc":"0,05 °C"},{"name":"","range":"1 °C 至 40 °C","cmc":"0,07 °C"},{"name":"","range":"40 °C 至 200 °C","cmc":"0,10 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až -1 °C","cmc":"0,06 °C"},{"name":"","range":"-1 °C až 1 °C","cmc":"0,05 °C"},{"name":"","range":"1 °C až 40 °C","cmc":"0,07 °C"},{"name":"","range":"40 °C až 200 °C","cmc":"0,10 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","technique_en":"Comparison with a standard digital thermometer in a liquid bath","technique_zh":"在液体槽中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej"],"techniques_en":["Comparison with a standard digital thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do -1 °C CMC 0,06 °C\nod -1 °C do 1 °C CMC 0,05 °C\nod 1 °C do 40 °C CMC 0,07 °C\nod 40 °C do 200 °C CMC 0,10 °C\nPorównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","reference":"KP-03-01, KP-03-02","norm_bases":["KP-03-01","KP-03-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane i cyfrowe Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej od -40 °C do -1 °C CMC 0,06 °C od -1 °C do 1 °C CMC 0,05 °C od 1 °C do 40 °C CMC 0,07 °C od 40 °C do 200 °C CMC 0,10 °C Teploměry skleněné a digitální Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v kapalinové lázni -40 °C až -1 °C CMC 0,06 °C -1 °C až 1 °C CMC 0,05 °C 1 °C až 40 °C CMC 0,07 °C 40 °C až 200 °C CMC 0,10 °C KP-03-01, KP-03-02 Termometry szklane i cyfrowe Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w lazni cieczowej od -40 °C do -1 °C CMC 0,06 °C od -1 °C do 1 °C CMC 0,05 °C od 1 °C do 40 °C CMC 0,07 °C od 40 °C do 200 °C CMC 0,10 °C Teplomery sklenene a digitalni Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v kapalinove lazni -40 °C az -1 °C CMC 0,06 °C -1 °C az 1 °C CMC 0,05 °C 1 °C az 40 °C CMC 0,07 °C 40 °C az 200 °C CMC 0,10 °C KP-03-01, KP-03-02","search_en":"Glass and digital thermometers Calibration – temperature Comparison with a standard digital thermometer in a liquid bath -40 °C to -1 °C CMC 0,06 °C -1 °C to 1 °C CMC 0,05 °C 1 °C to 40 °C CMC 0,07 °C 40 °C to 200 °C CMC 0,10 °C KP-03-01, KP-03-02","search_zh":"玻璃和数字温度计 校准 – 温度 在液体槽中与标准数字温度计比较 -40 °C 至 -1 °C CMC 0,06 °C -1 °C 至 1 °C CMC 0,05 °C 1 °C 至 40 °C CMC 0,07 °C 40 °C 至 200 °C CMC 0,10 °C KP-03-01, KP-03-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7194dc18f2ea7681a68e9590","lab_id":"6ade8b36ff06824761708116","country":"CZ","accr_number":"2323","accr_body":"ČIA","row_label":"2","test_object":"Tory pomiarowe temperatury","test_object_en":"Temperature measuring chains","test_object_zh":"温度测量链","test_object_cs":"Měřící řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 50 °C","cmc":"0,3 °C"},{"name":"","range":"od 50 °C do 120 °C","cmc":"0,4 °C"},{"name":"","range":"od 120 °C do 180 °C","cmc":"0,6 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 50 °C","cmc":"0,3 °C"},{"name":"","range":"50 °C to 120 °C","cmc":"0,4 °C"},{"name":"","range":"120 °C to 180 °C","cmc":"0,6 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 50 °C","cmc":"0,3 °C"},{"name":"","range":"50 °C 至 120 °C","cmc":"0,4 °C"},{"name":"","range":"120 °C 至 180 °C","cmc":"0,6 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 50 °C","cmc":"0,3 °C"},{"name":"","range":"50 °C až 120 °C","cmc":"0,4 °C"},{"name":"","range":"120 °C až 180 °C","cmc":"0,6 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym","technique_en":"Comparison with a digital standard thermometer","technique_zh":"与数字标准温度计比较","technique_cs":"Porovnání s digitálním etalonovým teploměrem","techniques":["Porównanie z cyfrowym termometrem wzorcowym"],"techniques_en":["Comparison with a digital standard thermometer"],"techniques_zh":["与数字标准温度计比较"],"techniques_cs":["Porovnání s digitálním etalonovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do 50 °C CMC 0,3 °C\nod 50 °C do 120 °C CMC 0,4 °C\nod 120 °C do 180 °C CMC 0,6 °C\nPorównanie z cyfrowym termometrem wzorcowym","reference":"KP-03-02","norm_bases":["KP-03-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym od -40 °C do 50 °C CMC 0,3 °C od 50 °C do 120 °C CMC 0,4 °C od 120 °C do 180 °C CMC 0,6 °C Měřící řetězce teploty Kalibrace – teplota Porovnání s digitálním etalonovým teploměrem -40 °C až 50 °C CMC 0,3 °C 50 °C až 120 °C CMC 0,4 °C 120 °C až 180 °C CMC 0,6 °C KP-03-02 Tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym od -40 °C do 50 °C CMC 0,3 °C od 50 °C do 120 °C CMC 0,4 °C od 120 °C do 180 °C CMC 0,6 °C Merici retezce teploty Kalibrace – teplota Porovnani s digitalnim etalonovym teplomerem -40 °C az 50 °C CMC 0,3 °C 50 °C az 120 °C CMC 0,4 °C 120 °C az 180 °C CMC 0,6 °C KP-03-02","search_en":"Temperature measuring chains Calibration – temperature Comparison with a digital standard thermometer -40 °C to 50 °C CMC 0,3 °C 50 °C to 120 °C CMC 0,4 °C 120 °C to 180 °C CMC 0,6 °C KP-03-02","search_zh":"温度测量链 校准 – 温度 与数字标准温度计比较 -40 °C 至 50 °C CMC 0,3 °C 50 °C 至 120 °C CMC 0,4 °C 120 °C 至 180 °C CMC 0,6 °C KP-03-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}