🇨🇿 PRIMA BILAVČÍK, s.r.o. PL
Metrology & calibration
PRIMA BILAVČÍK, s.r.o. is a calibration laboratory accredited by ČIA under number 2318 (Uherský Brod, Czech Republic). Its accreditation scope covers 106 calibration items in the following areas: Metrology & calibration. Calibrated items include: Angles, Balances with non-automatic function, Direct-indicating thermometers, Parallel gauge blocks - 4th order. Most frequently used calibration principles: Comparison with parallel gauge blocks, Direct measurement by a reference multimeter, Direct measurement on a reference calibrator.
At a glance
- Accreditation number: ČIA 2318
- Calibration items in scope: 106
- Types of calibrated items: 68
- Calibration principles used: 62
- City: Uherský Brod, Czech Republic
- Valid until: 01-12-2026
- Accreditation number
- 2318
- Accreditation body
- ČIA
- Address
- 9. května 1182, 688 01 Uherský Brod
- City
- Uherský Brod, Czech Republic
- Division
- Calibration laboratory
- Valid until
- 01-12-2026
What this laboratory calibrates (68)
- Angles — 4 calibration items
- Balances with non-automatic function — 4 calibration items
- Direct-indicating thermometers — 4 calibration items
- Parallel gauge blocks - 4th order — 4 calibration items
- Temperature calibrators, temperature indicators — 4 calibration items
- DC current / DC current sources — 3 calibration items
- Gauges of length and geometric quantities — 3 calibration items
- Length gauges — 3 calibration items
- AC current / AC current meters — 2 calibration items
- AC current / AC current sources — 2 calibration items
- AC voltage / AC voltage sources — 2 calibration items
- Angle gauges — 2 calibration items
- DC current / DC current meters — 2 calibration items
- DC resistance / DC resistance meters — 2 calibration items
- DC voltage / DC voltage sources — 2 calibration items
- and 53 more
Calibration principles (62)
- Comparison with parallel gauge blocks — 11 calibration items
- Direct measurement by a reference multimeter — 5 calibration items
- Direct measurement on a reference calibrator — 4 calibration items
- Direct measurement on a reference calibrator or comparison with a reference multimeter — 4 calibration items
- Comparison using a reference resistance thermometer — 3 calibration items
- Comparison with a reference thermocouple — 3 calibration items
- Direct measurement on a calibrator of inspection instruments — 3 calibration items
- Direct measurement on an oscilloscope calibrator — 3 calibration items
- Comparison with a humidity standard — 2 calibration items
- Comparison with a perpendicularity standard and parallel gauge blocks — 2 calibration items
- Comparison with angle gauges — 2 calibration items
- Comparison with setting rings — 2 calibration items
- Direct measurement by a coordinate measuring machine — 2 calibration items
- Direct measurement by a LaserTracker laser interferometer — 2 calibration items
- Direct measurement by a reference clamp multimeter or a current clamp — 2 calibration items
- and 47 more
Laboratory sections (3)
- Uherský Brod II — 55 calibration items
- Uherský Brod — 35 calibration items
- Mladá Boleslav — 16 calibration items
Laboratory locations
- PRIMA BILAVČÍK, s.r.o. (main site) — 9. května 1182, 688 01 Uherský Brod
- Uherský Brod — 9. května 1182, 688 01 Uherský Brod
- Mladá Boleslav — Komenského náměstí 90/10, 293 01 Mladá Boleslav
- Uherský Brod II — Antonína Dvořáka 1274, 688 01 Uherský Brod
Certificate information
- Certificate date
- 04.12.2025
Accreditation scope — calibration items (106)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Uherský Brod | |||||
| 1 | Slide gauges | Calibration – length 0 mm to 2000 mm · CMC (15·L +15) μm resol. 0.01 mm — 1000 mm to 2000 mm · CMC (15·L +30) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-01 | |
| 2 | Micrometers | Calibration – length from 0 mm to 1000 mm · CMC (15·L +1,5) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-02 | |
| 3 | Length gauges | Calibration – length 0 mm to 1040 mm · CMC (1,2·L +0,15) μm CMC for the field of measured quantity: Length |
Direct or comparative measurement by a distance meter | KP-PB-04 | |
| 4 | Parallel gauge blocks - 3rd order | Calibration – length from 0,5 mm to 100 mm · CMC (1·L +0,1) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-07 | |
| 5 | Parallel gauge blocks - 4th order | Calibration – length from 0,5 mm to 100 mm · CMC (2·L +0,2) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-07 | |
| 6 | Parallel gauge blocks - 4th order | Calibration – length from 100 mm to 1000 mm · CMC (1,2·L +0,17) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-07 | |
| 7 | Height gauges | Calibration – length from 0 mm to 1000 mm · CMC (1,2·L +1) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-12 | |
| 8 | Graduated scales, tape measures, measuring tapes | Calibration – length from 0 mm to 50 m · CMC (0,2·n) mm CMC for the field of measured quantity: Length |
Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler | KP-PB-14 | |
| 9 | Length gauges | Calibration – length from 0 mm to 300 mm · CMC (0,8·L +0,07) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-16 | |
| 10 | Gauges of length and geometric shapes by a laser interferometer | Calibration – length from 0 m to 20 m · CMC (0,8·L +0,03) μm CMC for the field of measured quantity: Length |
Direct measurement by a laser interferometer | KP-PB-19 | |
| 11 | Gauges of length, shape, geometric positions, angles with a laser interferometer and laser tracker | Calibration – length 0,2 m to 15 m · CMC (0,3·L +0,2) μm CMC for the field of measured quantity: Length |
Direct measurement by a LaserTracker laser interferometer | KP-PB-19 | |
| 12 | Angles | Calibration – length from 0 mm to 1000 mm · CMC 4 μm CMC for the field of measured quantity: Length |
Direct measurement using a coordinate measuring machine | KP-PB-26 | |
| 13 | Angles | Calibration – length from 0 mm to 1000 mm · CMC 6 μm CMC for the field of measured quantity: Length |
Comparison with a perpendicularity standard and parallel gauge blocks | KP-PB-26 | |
| 14 | Internal gauges | Calibration – length from 0 mm to 300 mm · CMC (3·L +2) μm CMC for the field of measured quantity: Length |
Comparison with setting rings | KP-PB-20 | |
| 15 | Contact, optical, multisensor coordinate measuring machines | Calibration – length 0 mm to 1600 mm · CMC (0,6·L +0,2) μm CMC for the field of measured quantity: Length |
Comparison with steel parallels and graduated scale | KP-PB-21 | |
| 16 | Coordinate measuring machines – manual mobile hinged arms | Calibration – length 0 mm to 3700 mm · CMC (2·L +20) μm CMC for the field of measured quantity: Length |
Comparison using step gauges | KP-PB-21 | |
| 17 | Coordinate measuring machines – proximity scanners | Calibration – length from 0 mm to 200 mm · CMC 3 μm 200 mm to 1500 mm · CMC 20 μm CMC for the field of measured quantity: Length |
Comparison with a measuring gauge | KP-PB-21 | |
| 18 | Coordinate measuring machines | Calibration – length from 0 m to 30 m · CMC 50 μm CMC for the field of measured quantity: Length |
Direct measurement by a LaserTracker laser interferometer | KP-PB-21 | |
| 19 | Coordinate measuring machines – tomographs | Calibration – length from 0 mm to 500 mm · CMC 3 μm CMC for the field of measured quantity: Length |
Comparison with a spherical standard | KP-PB-21 | |
| 20 | Surface roughness standards | Calibration – length 0,01 μm to 100 μm · CMC (0,06·L) μm CMC for the field of measured quantity: Length |
Direct measurement by a roughness meter | KP-PB-23 | |
| 21 | Roughness meters | Calibration – length 0,01 μm to 100 μm · CMC (0,035·L) μm CMC for the field of measured quantity: Length |
Comparison with a roughness standard | KP-PB-24 | |
| 22 | Ring gauges | Calibration – length roundness — 0 μm to 2000 μm · CMC 0,1 μm CMC for the field of measured quantity: Length |
Comparison with a reference sphere | KP-PB-31 | |
| 23 | Ring gauges | Calibration – length straightness — 0 μm to 2000 μm · CMC 0,11 μm CMC for the field of measured quantity: Length |
Comparison with a flat glass | KP-PB-31 | |
| 24 | Profilometers | Calibration – length from 0 mm to 600 mm · CMC (1,0·L +1,2) μm CMC for the field of measured quantity: Length |
Comparison with a contour standard | KP-PB-25 | |
| 25 | Gauges of length and geometric quantities | Calibration – length from 0 mm to 1000 mm · CMC (3·L +0,5) μm CMC for the field of measured quantity: Length |
Direct measurement by a coordinate measuring machine | KP-PB-27 | |
| 26 | Gauges of length and geometric quantities | Calibration – length from 0 mm to 300 mm · CMC (1,2·L +0,2) μm CMC for the field of measured quantity: Length |
Direct measurement by a ring gauge | KP-PB-27 | |
| 27 | 3D length gauges | Calibration – length 0 mm to 3200 mm · CMC 43 μm CMC for the field of measured quantity: Length |
Direct measurement by a mobile hinged arm | KP-PB-27 | |
| 28 | Laser distance meters | Calibration – length from 0 m to 20 m · CMC 0,9 mm CMC for the field of measured quantity: Length |
Direct measurement by a LaserTracker laser interferometer, comparison with a length standard | KP-PB-28 | |
| 29 | Surface layer thickness gauges | Calibration – length 0 mm to 2,0 mm · CMC (20·L +1,3) μm CMC for the field of measured quantity: Length |
Comparative measurement by a thickness standard | KP-PB-29 | |
| 30 | Angle gauges | Calibration – plane angle from 0 ° to 360 ° · CMC 3´ CMC for the field of measured quantity: Plane angle |
Comparison with angle gauges | KP-PB-15 | |
| 31 | Builder's levels | Calibration – plane angle -3 ° to 3 ° · CMC 0,7 mm/m CMC for the field of measured quantity: Plane angle |
Direct measurement on an index head, comparison with an angle gauge | KP-PB-36 | |
| 32 | Clinometers | Calibration – plane angle from -180 ° to 180 ° · CMC 0,15° CMC for the field of measured quantity: Plane angle |
Direct measurement on an index head, comparison with an angle gauge | KP-PB-36 | |
| 33 | Rotation angle of torque wrench | Calibration – plane angle 0 ° to 270 ° · CMC 0,32° CMC for the field of measured quantity: Plane angle |
Direct measurement by an angle sensor | KP-PB-40 | |
| 34 | Torque / torque wrenches, torque screwdrivers | Calibration – force from 0,2 N·m to 1000 N·m · CMC 0,4 % CMC for the field of measured quantity: Force |
Direct measurement by a torque sensor | KP-PB-40 | |
| 35 | Mechanical pressure gauges and electromechanical manometers | Calibration – pressure positive gauge pressure, gas — -100 kPa to -2 kPa · CMC 0,025 % + 10 Pa positive gauge pressure, gas — -2 kPa to 2 kPa · CMC 0,1 % + 1 digit positive gauge pressure, gas — 2 kPa to 10 kPa · CMC 0,025 % + 1 Pa positive gauge pressure, gas — 10 kPa to 100 kPa · CMC 0,025 % + 10 Pa positive gauge pressure, gas — 0,1 MPa to 2 MPa · CMC 0,025 % + 0,2 kPa positive gauge pressure, gas — 2 MPa to 6 MPa · CMC 0,025 % + 0,6 kPa positive gauge pressure, gas — 6 MPa to 7 MPa · CMC 1,4 kPa positive gauge pressure, liquid — 0 MPa to 6 MPa · CMC 0,025 % +0,6 kPa positive gauge pressure, liquid — 6 MPa to 16 MPa · CMC 0,025 % +1,6 kPa positive gauge pressure, liquid — 16 MPa to 60 MPa · CMC 0,025 % + 6 kPa positive gauge pressure, liquid — 60 MPa to 100 MPa · CMC 25 kPa positive gauge pressure, liquid — 100 MPa to 250 MPa · CMC 250 kPa absolute pressure, gas — 70 kPa to 100 kPa · CMC 0,025 % + 60 Pa absolute pressure, gas — 0,1 MPa to 2 MPa · CMC 0,025 % + 0,3 kPa absolute pressure, gas — 2 MPa to 6 MPa · CMC 0,025 % + 0,7 kPa absolute pressure, gas — 6 MPa to 7 MPa · CMC 1,5 kPa absolute pressure, liquid — 0,1 MPa to 6 MPa · CMC 0,025 % +0,7 kPa absolute pressure, liquid — 6 MPa to 16 MPa · CMC 0,025 % +1,7 kPa absolute pressure, liquid — 16 MPa to 60 MPa · CMC 0,025 % + 6,1 kPa barometric pressure, gas — 70 kPa to 120 kPa · CMC 0,05 kPa CMC for the field of measured quantity: Pressure |
Comparison with a reference pressure gauge | KP-PB-55 KP-PB-56 | |
| Mladá Boleslav | |||||
| 36 | Slide gauges | Calibration – length 0 mm to 2000 mm · CMC (15·L +15) μm resol. 0.01 mm — 1000 mm to 2000 mm · CMC (15·L +30) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-01 | |
| 37 | Micrometers | Calibration – length from 0 mm to 1000 mm · CMC (15·L +1,5) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-02 | |
| 38 | Length gauges | Calibration – length 0 mm to 1040 mm · CMC (1,2·L +0,15) μm CMC for the field of measured quantity: Length |
Direct or comparative measurement by a distance meter | KP-PB-04 | |
| 39 | Parallel gauge blocks - 4th order | Calibration – length from 0,5 mm to 100 mm · CMC (2·L +0,2) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-07 | |
| 40 | Parallel gauge blocks - 4th order | Calibration – length from 100 mm to 500 mm · CMC (2·L +0,2) μm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KP-PB-07 | |
| 41 | Graduated scales, tape measures, measuring tapes | Calibration – length from 0 mm to 50 m · CMC (0,2·n) mm CMC for the field of measured quantity: Length |
Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler | KP-PB-14 | |
| 42 | Angles | Calibration – length from 0 mm to 1000 mm · CMC 4 μm CMC for the field of measured quantity: Length |
Direct measurement using a coordinate measuring machine | KP-PB-26 | |
| 43 | Angles | Calibration – length from 0 mm to 1000 mm · CMC 6 μm CMC for the field of measured quantity: Length |
Comparison with a perpendicularity standard and parallel gauge blocks | KP-PB-26 | |
| 44 | Internal gauges | Calibration – length from 0 mm to 300 mm · CMC (3·L +2) μm CMC for the field of measured quantity: Length |
Comparison with setting rings | KP-PB-20 | |
| 45 | Gauges of length and geometric quantities | Calibration – length from 0 mm to 1000 mm · CMC (3·L +0,5) μm CMC for the field of measured quantity: Length |
Direct measurement by a coordinate measuring machine | KP-PB-27 | |
| 46 | Angle gauges | Calibration – plane angle from 0 ° to 360 ° · CMC 3´ CMC for the field of measured quantity: Plane angle |
Comparison with angle gauges | KP-PB-15 | |
| 47 | Rotation angle of torque wrench | Calibration – plane angle 0 ° to 270 ° · CMC 0,32° CMC for the field of measured quantity: Plane angle |
Direct measurement by an angle sensor | KP-PB-40 | |
| 48 | Torque / torque wrenches, torque screwdrivers | Calibration – force from 0,2 N·m to 1000 N·m · CMC 0,4 % CMC for the field of measured quantity: Force |
Direct measurement by a torque sensor | KP-PB-40 | |
| 49 | Direct-indicating thermometers | Calibration – temperature -100 °C to -60 °C · CMC 0,04 °C -60 °C to 0 °C · CMC 0,04 °C from 0 °C to 50 °C · CMC 0,03 °C 50 °C to 230 °C · CMC 0,04 °C 230 °C to 660 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison using a reference resistance thermometer | KP-PB-51 | |
| 50 | Direct-indicating thermometers | Calibration – temperature 660 °C to 700 °C · CMC 1,1 °C 700 °C to 1000 °C · CMC 1,2 °C from 1000 °C to 1100 °C · CMC 1,2 °C from 1100 °C to 1200 °C · CMC 1,4 °C from 1200 °C to 1500 °C · CMC 2,4 °C 1500 °C to 1600 °C · CMC 2,9 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference thermocouple | KP-PB-51 | |
| 51 | Relative humidity | Calibration – physicochemical quantities (10 to 60) °C — 10 % RH to 40 % RH · CMC 0,9 % RH (10 to 60) °C — 40 % RH to 70 % RH · CMC 1,0 % RH (10 to 60) °C — 70 % RH to 80 % RH · CMC 1,1 % RH (10 to 60) °C — 80 % RH to 90 % RH · CMC 1,2 % RH (10 to 60) °C — 90 % RH to 95 % RH · CMC 1,6 % RH CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a humidity standard | KP-PB-99 | |
| Uherský Brod II | |||||
| 52 | Balances with non-automatic function | Calibration – mass from 1 mg to 200 mg · CMC 0,018 mg from 200 mg to 1 g · CMC 0,026 mg from 1 g to 2 g · CMC 0,032 mg from 2 g to 10 g · CMC 0,050 mg from 10 g to 20 g · CMC 0,064 mg from 20 g to 50 g · CMC 0,078 mg from 50 g to 100 g · CMC 0,13 mg 100 g to 5 kg · CMC 1,3·10⁻⁶ CMC for the field of measured quantity: Mass |
Loading using a class E2 reference weight (acc. to OIML R111-1:2004) | KP-PB-71 | |
| 53 | Balances with non-automatic function | Calibration – mass 5 kg to 55 kg · CMC 6·10⁻⁶ CMC for the field of measured quantity: Mass |
Loading using a class F1 reference weight (acc. to OIML R111-1:2004) | KP-PB-71 | |
| 54 | Balances with non-automatic function | Calibration – mass 55 kg to 150 kg · CMC 2,2·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a class F2 reference weight (acc. to OIML R111-1:2004) | KP-PB-71 | |
| 55 | Balances with non-automatic function | Calibration – mass 150 kg to 1 t · CMC 7,3·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a class M1 reference weight (acc. to OIML R111-1:2004) | KP-PB-71 | |
| 56 | Conventional mass of weights and bodies | Calibration – mass from 1 mg to 5 mg · CMC 0,0020 mg 10 mg · CMC 0,0022 mg 20 mg · CMC 0,0023 mg 50 mg · CMC 0,0029 mg 100 mg · CMC 0,0035 mg 200 mg · CMC 0,0043 mg 500 mg · CMC 0,0053 mg 1 g · CMC 0,0064 mg 2 g · CMC 0,0083 mg 5 g · CMC 0,011 mg 10 g · CMC 0,013 mg 20 g · CMC 0,017 mg 50 g · CMC 0,024 mg 100 g · CMC 0,032 mg 200 g · CMC 0,062 mg 500 g · CMC 0,16 mg 1 kg · CMC 0,32 mg 2 kg · CMC 0,62 mg 5 kg · CMC 1,6 mg 10 kg · CMC 14 mg 20 kg · CMC 24 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight (acc. to OIML R111-1:2004) on reference scales and comparators | KP-PB-75 | |
| 57 | Force / Working force-proving instruments | Calibration – force Tension, pressure — 0,1 N to 200 N · CMC 0,05 % CMC for the field of measured quantity: Force |
Suspension by means of load bodies | KP-PB-41 | |
| 58 | Force / Working force-proving instruments | Calibration – force Tension, pressure — 10 N to 1000 N · CMC 0,07 % Tension, pressure — 1000 N to 2500 N · CMC 0,13 % FS CMC for the field of measured quantity: Force |
Direct measurement by a force sensor | KP-PB-41 | |
| 59 | Direct-indicating thermometers | Calibration – temperature -100 °C to -60 °C · CMC 0,04 °C -60 °C to 0 °C · CMC 0,04 °C from 0 °C to 50 °C · CMC 0,03 °C 50 °C to 230 °C · CMC 0,04 °C 230 °C to 660 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison using a reference resistance thermometer | KP-PB-51 | |
| 60 | Direct-indicating thermometers | Calibration – temperature 660 °C to 700 °C · CMC 1,1 °C 700 °C to 1000 °C · CMC 1,2 °C from 1000 °C to 1100 °C · CMC 1,2 °C from 1100 °C to 1200 °C · CMC 1,4 °C from 1200 °C to 1500 °C · CMC 2,4 °C 1500 °C to 1600 °C · CMC 2,9 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference thermocouple | KP-PB-51 | |
| 61 | Direct indicating thermometers – temperature measuring chains – externally | Calibration – temperature -100 °C to 230 °C · CMC 0,2 °C 230 °C to 660 °C · CMC 0,3 °C CMC for the field of measured quantity: Temperature |
Comparison using a reference resistance thermometer | KP-PB-51 | |
| 62 | Direct indicating thermometers – temperature measuring chains – externally | Calibration – temperature 660 °C to 700 °C · CMC 1,1 °C 700 °C to 1000 °C · CMC 2,1 °C from 1000 °C to 1100 °C · CMC 2,2 °C from 1100 °C to 1200 °C · CMC 2,3 °C from 1200 °C to 1500 °C · CMC 2,9 °C 1500 °C to 1600 °C · CMC 3,4 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference thermocouple | KP-PB-51 | |
| 63 | Temperature – contactless thermometers | Calibration – temperature from -20 °C to 0 °C · CMC 1,2 °C from 0 °C to 50 °C · CMC 1,3 °C from 50 °C to 100 °C · CMC 1,4 °C from 100 °C to 200 °C · CMC 1,9 °C from 200 °C to 300 °C · CMC 2,8 °C from 300 °C to 400 °C · CMC 3,4 °C from 400 °C to 500 °C · CMC 3,6 °C from 500 °C to 600 °C · CMC 3,9 °C from 600 °C to 800 °C · CMC 5,0 °C from 800 °C to 1000 °C · CMC 6,1 °C from 1000 °C to 1200 °C · CMC 7,3 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference black body | KP-PB-53 | |
| 64 | Temperature calibrators, temperature indicators | Calibration – temperature TC-J — -210 °C to 0 °C · CMC 0,15 °C TC-J — 0 °C to 1200 °C · CMC 0,08 °C TC-K — -270 °C to 0 °C · CMC 0,18 °C TC-K — 0 °C to 500 °C · CMC 0,09 °C TC-K — 500 °C to 1372 °C · CMC 0,12 °C TC-T — -270 °C to 0 °C · CMC 0,17 °C TC-T — 0 °C to 400 °C · CMC 0,05 °C TC-R — -50 °C to 250 °C · CMC 0,70 °C TC-R — 250 °C to 1768 °C · CMC 0,24 °C TC-S — -50 °C to 250 °C · CMC 0,64 °C TC-S — 250 °C to 1768 °C · CMC 0,24 °C TC-B — 250 °C to 1820 °C · CMC 0,41 °C TC-N — -270 °C to 0 °C · CMC 0,27 °C TC-N — 0 °C to 1300 °C · CMC 0,10 °C TC-E — -270 °C to 0 °C · CMC 0,12 °C TC-E — 0 °C to 1000 °C · CMC 0,07 °C CMC for the field of measured quantity: Temperature |
Direct generation of equivalent DC voltage for TC – without cold junction compensation | KP-PB-122 | |
| 65 | Temperature calibrators, temperature indicators | Calibration – temperature TC-J — -210 °C to 0 °C · CMC 0,08 °C TC-J — 0 °C to 1200 °C · CMC 0,07 °C TC-K — -270 °C to 0 °C · CMC 0,09 °C TC-K — 0 °C to 500 °C · CMC 0,06 °C TC-K — 500 °C to 1372 °C · CMC 0,07 °C TC-T — -270 °C to 0 °C · CMC 0,09 °C TC-T — 0 °C to 400 °C · CMC 0,03 °C TC-R — -50 °C to 250 °C · CMC 0,32 °C TC-R — 250 °C to 1064 °C · CMC 0,09 °C TC-R — 1064 °C to 1768 °C · CMC 0,10 °C TC-S — -50 °C to 250 °C · CMC 0,29 °C TC-S — 250 °C to 1064 °C · CMC 0,10 °C TC-S — 1064 °C to 1768 °C · CMC 0,12 °C TC-B — 250 °C to 700 °C · CMC 0,18 °C TC-B — 700 °C to 1820 °C · CMC 0,11 °C TC-N — -270 °C to 0 °C · CMC 0,12 °C TC-N — 0 °C to 600 °C · CMC 0,04 °C TC-N — 600 °C to 1300 °C · CMC 0,04 °C TC-E — -270 °C to 0 °C · CMC 0,05 °C TC-E — 0 °C to 1000 °C · CMC 0,03 °C CMC for the field of measured quantity: Temperature |
Direct measurement of equivalent DC voltage for TC – without cold junction compensation | KP-PB-122 | |
| 66 | Temperature calibrators, temperature indicators | Calibration – temperature Pt 100 (3850) — -100 °C · CMC 0,03 °C Pt 100 (3850) — 0 °C · CMC 0,03 °C Pt 100 (3850) — 30 °C · CMC 0,04 °C Pt 100 (3850) — 60 °C · CMC 0,04 °C Pt 100 (3850) — 100 °C · CMC 0,04 °C Pt 100 (3850) — 200 °C · CMC 0,05 °C Pt 100 (3850) — 400 °C · CMC 0,07 °C Pt 100 (3850) — 800 °C · CMC 0,13 °C Pt 100 (3850) — -200 °C to 0 °C · CMC 0,15 °C Pt 100 (3850) — 0 °C to 800 °C · CMC 0,43 °C Pt 500 (3850) — -200 °C to 260 °C · CMC 0,12 °C Pt 500 (3850) — 260 °C to 800 °C · CMC 0,45 °C Pt 1000 (3850) — -200 °C to 0 °C · CMC 0,05 °C Pt 1000 (3850) — 0 °C to 800 °C · CMC 0,45 °C Ni 100 (6180) — -60 °C to 0 °C · CMC 0,12 °C Ni 100 (6180) — 0 °C · CMC 0,02 °C Ni 100 (6180) — 0 °C to 250 °C · CMC 0,21 °C Ni 120 (6720) — -80 °C to 0 °C · CMC 0,08 °C Ni 120 (6720) — 0 °C to 260 °C · CMC 0,11 °C Ni 1000 (6180) — -50 °C to 0 °C · CMC 0,03 °C Ni 1000 (6180) — 0 °C to 200 °C · CMC 0,15 °C CMC for the field of measured quantity: Temperature |
Direct generation of equivalent resistance for RTD | KP-PB-122 | |
| 67 | Temperature calibrators, temperature indicators | Calibration – temperature Pt 100 (385) — -200 °C to 800 °C · CMC 0,03 °C Pt 500 (385) — -200 °C to 800 °C · CMC 0,10 °C Pt 1000 (385) — -200 °C to 800 °C · CMC 0,16 °C Ni 100 (6180) — -60 °C to 250 °C · CMC 0,02 °C Ni 120 (6720) — -60 °C to 250 °C · CMC 0,02 °C Ni 1000 (6180) — -60 °C to 200 °C · CMC 0,02 °C CMC for the field of measured quantity: Temperature |
Direct measurement of equivalent resistance for RTD | KP-PB-122 | |
| 68 | DC voltage / DC voltage sources | Calibration – electrical quantities from 0 mV to 120 mV · CMC 8,0 µV/V + 0,2 µV from 0,12 V to 1,2 V · CMC 5,7 µV/V + 0,61 µV from 1,2 V to 12 V · CMC 5,5 µV/V + 6,1 µV from 12 V to 120 V · CMC 8,1 µV/V + 81 µV 120 V to 1050 V · CMC 8,1 µV/V + 1,2 mV CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a reference multimeter | KP-PB-110 | |
| 69 | DC voltage / DC voltage sources | Calibration – electrical quantities 1,05 kV to 10 kV · CMC 1,2 % CMC for the field of measured quantity: Electrical quantities |
Measurement with a reference multimeter with HV probe | KP-PB-110 | |
| 70 | DC voltage / DC voltage meters | Calibration – electrical quantities from 0 mV to 200 mV · CMC 15 µV/V + 2,3 µV from 0,2 V to 2 V · CMC 8,8 µV/V + 2,6 µV from 2 V to 20 V · CMC 7,5 µV/V + 25 µV from 20 V to 200 V · CMC 13 µV/V + 0,28 mV from 200 V to 1020 V · CMC 13 µV/V + 1,8 mV CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator or comparison with a reference multimeter | KP-PB-110 | |
| 71 | DC current / DC current sources | Calibration – electrical quantities from 0 µA to 120 µA · CMC 23 µA/A + 0,42 nA from 0,12 mA to 1,2 mA · CMC 14 µA/A + 4,1 nA from 1,2 mA to 12 mA · CMC 16 µA/A + 41 nA from 12 mA to 120 mA · CMC 42 µA/A + 0,61 µA 0,12 A to 1,2 A · CMC 0,020 % + 13 µA 1,2 A to 10 A · CMC 0,048 % + 0,35 mA from 10 A to 30 A · CMC 0,064 % + 4,4 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a reference multimeter | KP-PB-111 | |
| 72 | DC current / DC current sources | Calibration – electrical quantities from 10 A to 30 A · CMC 0,031 % 30 A to 70 A · CMC 0,083 % 70 A to 200 A · CMC 0,064 % 200 to 300 A · CMC 0,060 % CMC for the field of measured quantity: Electrical quantities |
Indirect measurement using a reference shunt and multimeter. | KP-PB-111 | |
| 73 | DC current / DC current sources | Calibration – electrical quantities 0 A to 200 A · CMC 1,2 % +0,5 A from 200 A to 2000 A · CMC 1,0 % +4,5 A CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a reference clamp multimeter or a current clamp | KP-PB-111 | |
| 74 | DC current / DC current meters | Calibration – electrical quantities from 0 µA to 200 µA · CMC 91 µA/A + 10 nA from 0,2 mA to 2 mA · CMC 46 µA/A + 30 nA from 2 mA to 20 mA · CMC 46 µA/A + 0,21 µA from 20 mA to 200 mA · CMC 51 µA/A + 2,2 µA from 0,2 A to 2 A · CMC 87 µA/A + 32 µA from 2 A to 20 A · CMC 0,023 % + 0,30 mA from 20 A to 30 A · CMC 0,034 % + 0,94 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator or comparison with a reference multimeter | KP-PB-111 | |
| 75 | DC current / DC current meters | Calibration – electrical quantities 30 A to 60 A · CMC 0,64 % + 0,10 A 60 A to 300 A · CMC 0,78 % + 0,13 A 300 A to 1500 A · CMC 0,60 % + 0,42 A CMC for the field of measured quantity: Electrical quantities |
Measurement of a current simulated by a calibrator with current coil | KP-PB-111 | |
| 76 | AC voltage / AC voltage sources | Calibration – electrical quantities 10 Hz to 40 Hz — 0 mV to 100 mV · CMC 0,061 % + 19 µV 40 Hz to 200 Hz — 0 mV to 100 mV · CMC 0,027 % + 15 µV 200 Hz to 2 kHz — 0 mV to 100 mV · CMC 0,023 % + 13 µV 2 kHz to 20 kHz — 0 mV to 100 mV · CMC 0,032 % + 14 µV 20 kHz to 100 kHz — 0 mV to 100 mV · CMC 0,081 % + 51 µV 10 Hz to 40 Hz — 0,1 V to 1 V · CMC 0,048 % + 0,24 mV 40 Hz to 200 Hz — 0,1 V to 1 V · CMC 0,023 % + 61 µV 200 Hz to 2 kHz — 0,1 V to 1 V · CMC 0,018 % + 61 µV 2 kHz to 20 kHz — 0,1 V to 1 V · CMC 0,030 % + 0,10 mV 20 kHz to 100 kHz — 0,1 V to 1 V · CMC 0,072 % + 0,50 mV 100 kHz to 1 MHz — 0,1 V to 1 V · CMC 1,2 % + 25 mV 10 Hz to 40 Hz — 1 V to 10 V · CMC 0,048 % + 2,3 mV 40 Hz to 200 Hz — 1 V to 10 V · CMC 0,021 % + 0,61 mV 200 Hz to 2 kHz — 1 V to 10 V · CMC 0,018 % + 0,61 mV 2 kHz to 20 kHz — 1 V to 10 V · CMC 0,030 % + 1,0 mV 20 kHz to 100 kHz — 1 V to 10 V · CMC 0,072 % + 5,0 mV 100 kHz to 200 kHz — 1 V to 10 V · CMC 1,2 % + 0,25 V 10 Hz to 40 Hz — 10 V to 100 V · CMC 0,060 % + 23 mV 40 Hz to 200 Hz — 10 V to 100 V · CMC 0,024 % + 10 mV 200 Hz to 2 kHz — 10 V to 100 V · CMC 0,022 % + 7,1 mV 2 kHz to 20 kHz — 10 V to 100 V · CMC 0,033 % + 11 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 0,11 % + 62 mV 10 Hz to 40 Hz — 100 V to 1000 V · CMC 0,060 % + 0,16 V 40 Hz to 200 Hz — 100 V to 1000 V · CMC 0,021 % + 0,10 V 200 Hz to 2 kHz — 100 V to 1000 V · CMC 0,022 % + 0,10 V 2 kHz to 10 kHz — 100 V to 1000 V · CMC 0,037 % + 0,11 V CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a reference multimeter | KP-PB-112 | |
| 77 | AC voltage / AC voltage sources | Calibration – electrical quantities 50 Hz — 1 kV to 10 kV · CMC 2,2 % CMC for the field of measured quantity: Electrical quantities |
Measurement with a reference multimeter with HV probe | KP-PB-112 | |
| 78 | AC voltage / AC voltage meters | Calibration – electrical quantities 10 Hz to 45 Hz — 0 mV to 202 mV · CMC 0,071 % + 24 µV 45 Hz to 1 kHz — 0 mV to 202 mV · CMC 0,018 % + 24 µV 1 kHz to 20 kHz — 0 mV to 202 mV · CMC 0,020 % + 33 µV 20 kHz to 100 kHz — 0 mV to 202 mV · CMC 0,13 % + 56 µV 100 kHz to 500 kHz — 0 mV to 202 mV · CMC 0,35 % + 0,10 mV 10 Hz to 45 Hz — 0,202 V to 2,02 V · CMC 0,053 % + 0,21 mV 45 Hz to 1 kHz — 0,202 V to 2,02 V · CMC 0,019 % + 0,12 mV 1 kHz to 20 kHz — 0,202 V to 2,02 V · CMC 0,020 % + 0,21 mV 20 kHz to 100 kHz — 0,202 V to 2,02 V · CMC 0,067 % + 0,30 mV 100 kHz to 500 kHz — 0,202 V to 2,02 V · CMC 0,29 % + 0,46 mV 10 Hz to 45 Hz — 2,02 V to 20,2 V · CMC 0,050 % + 2,0 mV 45 Hz to 1 kHz — 2,02 V to 20,2 V · CMC 0,017 % + 1,3 mV 1 kHz to 20 kHz — 2,02 V to 20,2 V · CMC 0,021 % + 1,8 mV 20 kHz to 100 kHz — 2,02 V to 20,2 V · CMC 0,083 % + 3,8 mV 30 Hz to 45 Hz — 20,2 V to 202 V · CMC 0,050 % + 24 mV 45 Hz to 1 kHz — 20,2 V to 202 V · CMC 0,017 % + 13 mV 1 kHz to 10 kHz — 20,2 V to 202 V · CMC 0,021 % + 19 mV 10 kHz to 40 kHz — 20,2 V to 202 V · CMC 0,035 % + 31 mV 30 Hz to 45 Hz — 202 V to 1020 V · CMC 0,060 % + 0,21 V 45 Hz to 1 kHz — 202 V to 1020 V · CMC 0,024 % + 0,08 V 1 kHz to 10 kHz — 202 V to 1020 V · CMC 0,039 % + 0,13 V CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator or comparison with a reference multimeter | KP-PB-112 | |
| 79 | AC current / AC current sources | Calibration – electrical quantities 10 Hz to 40 Hz — 0 µA to 100 µA · CMC 0,061 % + 24 nA 40 Hz to 1 kHz — 0 µA to 100 µA · CMC 0,039 % + 16 nA 1 kHz to 10 kHz — 0 µA to 100 µA · CMC 0,083 % + 32 nA 10 Hz to 40 Hz — 100 µA to 1 mA · CMC 0,058 % + 0,21 µA 40 Hz to 1 kHz — 100 µA to 1 mA · CMC 0,037 % + 0,19 µA 1 kHz to 10 kHz — 100 µA to 1 mA · CMC 0,082 % + 0,31 µA 10 Hz to 40 Hz — 1 mA to 10 mA · CMC 0,058 % + 3,1 µA 40 Hz to 1 kHz — 1 mA to 10 mA · CMC 0,037 % + 1,9 µA 1 kHz to 10 kHz — 1 mA to 10 mA · CMC 0,081 % + 3,1 µA 10 Hz to 40 Hz — 10 mA to 100 mA · CMC 0,059 % + 27 µA 40 Hz to 1 kHz — 10 mA to 100 mA · CMC 0,035 % + 12 µA 1 kHz to 10 kHz — 10 mA to 100 mA · CMC 0,082 % + 30 µA 10 Hz to 40 Hz — 100 mA to 1 A · CMC 0,074 % + 0,34 mA 40 Hz to 1 kHz — 100 mA to 1 A · CMC 0,054 % + 0,17 mA 1 kHz to 10 kHz — 100 mA to 1 A · CMC 0,081 % + 0,5 mA 10 Hz to 40 Hz — 1 A to 10 A · CMC 0,10 % + 5,8 mA 40 Hz to 1 kHz — 1 A to 10 A · CMC 0,091 % + 3,2 mA 10 Hz to 40 Hz — 10 A to 30 A · CMC 0,093 % + 13 mA 40 Hz to 1 kHz — 10 A to 30 A · CMC 0,082 % + 9,1 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a reference multimeter | KP-PB-113 | |
| 80 | AC current / AC current sources | Calibration – electrical quantities 30 Hz to 60 Hz — 0 A to 4 A · CMC 0,72 % + 0,003 A 30 Hz to 60 Hz — 4 A to 40 A · CMC 0,71 % + 0,03 A 30 Hz to 60 Hz — 40 A to 200 A · CMC 1,2 % + 0,5 A 30 Hz to 60 Hz — 200 A to 400 A · CMC 1,1 % + 1,3 A 30 Hz to 60 Hz — 400 A to 1500 A · CMC 1,3 % + 1,6 A 30 Hz to 60 Hz — 1500 A to 2000 A · CMC 1,1 % + 4,6 A CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a reference clamp multimeter or a current clamp | KP-PB-113 | |
| 81 | AC current / AC current meters | Calibration – electrical quantities 10 Hz to 45 Hz — 10 µA to 202 µA · CMC 0,20 % + 0,25 µA 45 Hz to 1 kHz — 10 µA to 202 µA · CMC 0,071 % + 0,15 µA 1 kHz to 10 kHz — 10 µA to 202 µA · CMC 0,96 % + 0,20 µA 10 Hz to 45 Hz — 0,202 mA to 2,02 mA · CMC 0,19 % + 0,31 µA 45 Hz to 1 kHz — 0,202 mA to 2,02 mA · CMC 0,055 % + 0,27 µA 1 kHz to 10 kHz — 0,202 mA to 2,02 mA · CMC 0,50 % + 0,35 µA 10 Hz to 45 Hz — 2,02 mA to 20,2 mA · CMC 0,19 % + 4,1 µA 45 Hz to 1 kHz — 2,02 mA to 20,2 mA · CMC 0,048 % + 2,5 µA 1 kHz to 10 kHz — 2,02 mA to 20,2 mA · CMC 0,25 % + 3,4 µA 10 Hz to 45 Hz — 20,2 mA to 202 mA · CMC 0,19 % + 41 µA 45 Hz to 1 kHz — 20,2 mA to 202 mA · CMC 0,049 % + 25 µA 1 kHz to 10 kHz — 20,2 mA to 202 mA · CMC 0,50 % + 43 µA 10 Hz to 45 Hz — 0,202 A to 2,02 A · CMC 0,19 % + 0,36 mA 45 Hz to 1 kHz — 0,202 A to 2,02 A · CMC 0,064 % + 0,28 mA 1 kHz to 5 kHz — 0,202 A to 2,02 A · CMC 0,50 % + 0,45 mA 30 Hz to 45 Hz — 2,02 A to 30 A · CMC 0,19 % + 3,5 mA 45 Hz to 100 Hz — 2,02 A to 30 A · CMC 0,059 % + 2,5 mA 100 Hz to 1 kHz — 2,02 A to 30 A · CMC 0,50 % + 4,3 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator or comparison with a reference multimeter | KP-PB-113 | |
| 82 | AC current / AC current meters | Calibration – electrical quantities 30 to 60 Hz — 30 A to 60 A · CMC 0,43 % + 0,07 A 30 to 60 Hz — 60 A to 300 A · CMC 0,50 % + 0,07 A 30 to 60 Hz — 300 A to 1500 A · CMC 0,48 % + 0,08 A CMC for the field of measured quantity: Electrical quantities |
Measurement of a current simulated by a calibrator with current coil | KP-PB-113 | |
| 83 | DC resistance / Resistors and resistance boxes | Calibration – electrical quantities from 0 Ω to 1 Ω · CMC 20 µΩ/Ω + 6,1 µΩ from 1 Ω to 10 Ω · CMC 11 µΩ/Ω + 31 µΩ from 10 Ω to 100 Ω · CMC 10 µΩ/Ω + 0,10 mΩ from 100 Ω to 1 kΩ · CMC 9,1 µΩ/Ω + 0,81 mΩ from 1 kΩ to 10 kΩ · CMC 11 µΩ/Ω + 8,1 mΩ from 10 kΩ to 100 kΩ · CMC 12 µΩ/Ω + 81 mΩ from 0,1 MΩ to 1 MΩ · CMC 13 µΩ/Ω + 2 Ω from 1 MΩ to 10 MΩ · CMC 18 µΩ/Ω + 80 Ω from 10 MΩ to 90 MΩ · CMC 0,019 % from 90 MΩ to 900 MΩ · CMC 0,051 % 0,9 GΩ to 9 GΩ · CMC 0,20 % 9 GΩ to 2000 GΩ · CMC 2,5 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a reference multimeter | KP-PB-114 | |
| 84 | DC resistance / DC resistance meters | Calibration – electrical quantities 0 Ω · CMC 5,5 mΩ 0,0001 Ω · CMC 0,0073 % 0,001 Ω · CMC 0,0029 % 0,01 Ω · CMC 0,0022 % 0,1 Ω · CMC 0,0020 % 1 Ω · CMC 0,0020 % 10 Ω · CMC 0,0005 % 100 Ω · CMC 0,0004 % 1 kΩ · CMC 0,0039 % 10 kΩ · CMC 0,0019 % 100 kΩ · CMC 0,0031 % 1 MΩ · CMC 0,0046 % 10 MΩ · CMC 0,018 % 100 MΩ · CMC 0,35 % 1 GΩ · CMC 1,0 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement of fixed resistance standards or direct measurement on a calibrator or comparison with a reference multimeter | KP-PB-114 | |
| 85 | DC resistance / DC resistance meters | Calibration – electrical quantities 0 Ω to 1 kΩ · CMC 0,020 % + 50 mΩ from 1 kΩ to 10 kΩ · CMC 0,020 % + 58 mΩ from 10 kΩ to 100 kΩ · CMC 0,020 % + 0,30 Ω from 0,1 MΩ to 1 MΩ · CMC 0,020 % + 4,0 Ω from 1 MΩ to 10 MΩ · CMC 0,020 % +0,13 kΩ CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a calibrator | KP-PB-114 | |
| 86 | AC resistance / AC resistance meters | Calibration – electrical quantities 1 kHz — 10 Ω · CMC 0,013 % 100 kHz — 10 Ω · CMC 0,043 % 1 kHz — 50 Ω · CMC 0,013 % 1 kHz — 100 Ω · CMC 0,013 % 100 kHz — 50 Ω · CMC 0,021 % 100 kHz — 100 Ω · CMC 0,021 % 1 kHz — 1 kΩ · CMC 0,011 % 100 kHz — 1 kΩ · CMC 0,021 % 1 kHz — 10 kΩ · CMC 0,011 % 100 kHz — 10 kΩ · CMC 0,041 % 1 kHz — 100 kΩ · CMC 0,03 % 100 kHz — 100 kΩ · CMC 0,12 % 1 kHz — 1 MΩ · CMC 0,03 % 100 kHz — 1 MΩ · CMC 0,38 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on resistance standards | KP-PB-115 | |
| 87 | DC Power / DC Power Meters (for voltage from 1 V to 1,000 V and current from 0.5 mA to 30 A) | Calibration – electrical quantities 0,5 mW to 30 kW · CMC 0,072 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator | KP-PB-123 | |
| 88 | DC Power / DC Power Meters (for voltage 1 V to 1,000 V and current 30 A to 1,500 A) | Calibration – electrical quantities 30 kW to 1500 kW · CMC 0,74 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator with current coil | KP-PB-123 | |
| 89 | AC active power single phase/ AC active power meters (for voltage from 1 V to 1,000 V and current from 0.5 mA to 30 A, frequency from 40 Hz to 400 Hz), capacitive and inductive | Calibration – electrical quantities cos φ 1 — 0,5 mW to 30 kW · CMC 0,13 % cos φ 0.8 to 0.9 — 0,5 mW to 30 kW · CMC 0,32 % cos φ 0.7 to 0.8 — 0,5 mW to 30 kW · CMC 0,46 % cos φ 0.6 to 0.7 — 0,5 mW to 30 kW · CMC 0,62 % cos φ 0.5 to 0.6 — 0,5 mW to 30 kW · CMC 0,8 % cos φ 0.4 to 0.5 — 0,5 mW to 30 kW · CMC 1,0 % cos φ 0.3 to 0.4 — 0,5 mW to 30 kW · CMC 1,4 % cos φ 0.2 to 0.3 — 0,5 mW to 30 kW · CMC 1,9 % cos φ 0.1 to 0.2 — 0,5 mW to 30 kW · CMC 2,9 % cos φ 0.1 — 0,5 mW to 30 kW · CMC 5,9 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator | KP-PB-123 | |
| 90 | AC active power single phase/ AC active power meters (for voltage 1 V to 1,000 V and current 30 A to 1,500 A, frequency 30 Hz to 60 Hz) | Calibration – electrical quantities cos φ 1 — 30 kW to 1500 kW · CMC 0,95 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator with current coil | KP-PB-123 | |
| 91 | Capacity / Capacity meters | Calibration – electrical quantities 10 Hz to 1 kHz — 1 nF · CMC 0,30 % 1 kHz — 10 nF · CMC 0,30 % 100 kHz — 10 nF · CMC 1,5 % 10 Hz to 1 kHz — 20 nF · CMC 0,30 % 10 Hz to 1 kHz — 50 nF · CMC 0,30 % 10 Hz to 1 kHz — 100 nF · CMC 0,30 % 10 Hz to 1 kHz — 1 µF · CMC 0,49 % 10 Hz to 1 kHz — 10 µF · CMC 0,72 % 1 kHz — 100 µF · CMC 5,1 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator or direct measurement on capacity standards | KP-PB-115 | |
| 92 | Inductance / Inductance meters | Calibration – electrical quantities 1 kHz — 1 mH · CMC 0,61 % 1 kHz — 10 mH · CMC 0,61 % 1 kHz — 20 mH · CMC 0,61 % 1 kHz — 30 mH · CMC 0,61 % 1 kHz — 50 mH · CMC 0,61 % 1 kHz — 100 mH · CMC 0,61 % 1 kHz — 1 H · CMC 0,67 % 1 kHz — 10 H · CMC 0,78 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a reference calibrator | KP-PB-115 | |
| 93 | Inspection equipment / Insulation resistance | Calibration – electrical quantities Measuring voltage up to 5,000 V — 0,01 MΩ to 5 MΩ · CMC 0,12 % Measuring voltage up to 5,000 V — 5 MΩ to 121 MΩ · CMC 0,22 % Measuring voltage up to 5,000 V — 122 MΩ to 1,221 GΩ · CMC 0,52 % Measuring voltage up to 5,000 V — 1,22 GΩ to 12,221 GΩ · CMC 1,2 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a calibrator of inspection instruments or a reference resistance box | KP-PB-120 | |
| 94 | Inspection equipment / Mains impedance at 50 Hz | Calibration – electrical quantities Z₀= 0 Ω to 2 Ω · CMC 20 mΩ 50 mΩ + Z₀ · CMC 2,4 mΩ 100 mΩ + Z₀ · CMC 3,8 mΩ 220 mΩ + Z₀ · CMC 6,6 mΩ 330 mΩ + Z₀ · CMC 9,6 mΩ 500 mΩ + Z₀ · CMC 12 mΩ 1 Ω + Z₀ · CMC 16 mΩ 5 Ω + Z₀ · CMC 32 mΩ 10 Ω + Z₀ · CMC 54 mΩ 100 Ω + Z₀ · CMC 0,50 Ω 1 kΩ + Z₀ · CMC 5,0 Ω CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a calibrator of inspection instruments | KP-PB-120 | |
| 95 | Inspection equipment / Transient resistance | Calibration – electrical quantities 50 Hz — 0,01 Ω · CMC 0,60 % 50 Hz — 0,1 Ω · CMC 0,20 % 50 Hz — 1 Ω · CMC 0,011 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on impedance standards | KP-PB-120 | |
| 96 | Inspection equipment / Leakage current | Calibration – electrical quantities 2 mA · CMC 1,7 % 4,7 mA · CMC 1,7 % 7,7 mA · CMC 1,7 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a calibrator of inspection instruments or direct measurement with a multimeter | KP-PB-120 | |
| 97 | Inspection equipment / Tripping current of residual current circuit breakers | Calibration – electrical quantities 2 mA to 3000 mA · CMC 1,4 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a calibrator of inspection instruments | KP-PB-120 | |
| 98 | Inspection equipment / Tripping time of residual current circuit breakers | Calibration – electrical quantities 10 ms to 400 ms · CMC 0,40 ms CMC for the field of measured quantity: Electrical quantities |
Direct measurement on a calibrator of inspection instruments | KP-PB-120 | |
| 99 | Oscilloscope / Vertical amplifier | Calibration – electrical quantities 0 Hz — 2 mV to 50 V · CMC 0,012 % + 20 µV 1 kHz — 2 mV to 50 V · CMC 0,13 % + 40 µV CMC for the field of measured quantity: Electrical quantities |
Direct measurement on an oscilloscope calibrator | KP-PB-121 | |
| 100 | Oscilloscope / Time base | Calibration – electrical quantities 2 ns to 5 s · CMC 0,010 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on an oscilloscope calibrator | KP-PB-121 | |
| 101 | Oscilloscope / Limit frequency | Calibration – electrical quantities 50 Ω 600 mVp-p — 5 MHz to 600 MHz · CMC 15 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement on an oscilloscope calibrator | KP-PB-121 | |
| 102 | Frequency / Frequency generators | Calibration – time and frequency quantities 0,001 Hz to 20 GHz · CMC 9,3·10⁻⁸ CMC for the field of measured quantity: Time and frequency quantities |
Direct measurement by a reference counter | KP-PB-100 | |
| 103 | Frequency / frequency meters | Calibration – time and frequency quantities sine wave signal — 1 Hz to 10 MHz · CMC 20·10⁻⁶ CMC for the field of measured quantity: Time and frequency quantities |
Direct measurement on a reference calibrator | KP-PB-100 | |
| 104 | Time interval / Manually operated time meters | Calibration – time and frequency quantities 0:00:00 h:min:s to 23:59:59 h:min:s · CMC 0,10 s CMC for the field of measured quantity: Time and frequency quantities |
Comparison with a time interval standard | KP-PB-100 | |
| 105 | Time base of digital stopwatch | Calibration – time and frequency quantities from 10 Hz to 10 MHz · CMC 4,7·10⁻⁶ CMC for the field of measured quantity: Time and frequency quantities |
Indirect measurement by a reference counter | KP-PB-100 | |
| 106 | Relative humidity | Calibration – physicochemical quantities (10 to 60) °C — 10 % RH to 40 % RH · CMC 0,9 % RH (10 to 60) °C — 40 % RH to 70 % RH · CMC 1,0 % RH (10 to 60) °C — 70 % RH to 80 % RH · CMC 1,1 % RH (10 to 60) °C — 80 % RH to 90 % RH · CMC 1,2 % RH (10 to 60) °C — 90 % RH to 95 % RH · CMC 1,6 % RH CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a humidity standard | KP-PB-99 | |
Reference standards (40)
KP-PB-01
KP-PB-02
KP-PB-04
KP-PB-07
KP-PB-100
KP-PB-110
KP-PB-111
KP-PB-112
KP-PB-113
KP-PB-114
KP-PB-115
KP-PB-12
KP-PB-120
KP-PB-121
KP-PB-122
KP-PB-123
KP-PB-14
KP-PB-15
KP-PB-16
KP-PB-19
KP-PB-20
KP-PB-21
KP-PB-23
KP-PB-24
KP-PB-25
KP-PB-26
KP-PB-27
KP-PB-28
KP-PB-29
KP-PB-31
KP-PB-36
KP-PB-40
KP-PB-41
KP-PB-51
KP-PB-53
KP-PB-55
KP-PB-56
KP-PB-71
KP-PB-75
KP-PB-99