{"lab":{"_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","address":"9. května 1182, 688 01 Uherský Brod","categories":["metrology"],"city":"Uherský Brod","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[17.6393413,49.0275038]},"map_coord":[49.0275038,17.6393413],"map_geo":"cai-mapa","methods_count":106,"name":"PRIMA BILAVČÍK, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów pomiarowych w dziedzinach: długość, kąt płaski, masa, siła, ciśnienie, temperatura, wielkości elektryczne, wielkości czasu i częstotliwości, wielkości fizykochemiczne, w zakresie określonym w załączniku do świadectwa.","search_text":"prima bilavčík, s.r.o. 9. května 1182, 688 01 uherský brod 2318","source_page_url":"https://www.cai.cz/?subjekt=2318-prima-bilavcik-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"01-12-2026","website":"www.metrologie.cz","certificate_date":"04.12.2025","certificate_no":"622/2025","certificate_replaces":"462/2024 z 10.09.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów pomiarowych w dziedzinach: długość, kąt płaski, masa, siła, ciśnienie, temperatura, wielkości elektryczne, wielkości czasu i częstotliwości, wielkości fizykochemiczne, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of length, plane angle, mass, force, pressure, temperature, electrical quantities, time quantities and frequency, physicochemical quantities to the extent as specified in the appendix to this Certificate.","zh":"长度、平面角、质量、力、压力、温度、电学量、时间和频率量、物理化学量领域测量器具的校准，范围见本证书附件。","cs":"Kalibrace měřidel v oboru délka, rovinný úhel, hmotnost, síla, tlak, teplota, elektrické veličiny, veličiny času a frekvence, fyzikálně chemické veličiny, vymezené přílohou tohoto osvědčení.","de":"Kalibrierung von Messgeräten in den Bereichen: Länge, ebener Winkel, Masse, Kraft, Druck, Temperatur, elektrische Größen, Zeit- und Frequenzgrößen, physikalisch-chemische Größen, im Umfang gemäß Anlage zur Akkreditierungsurkunde."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration laboratory","lab_division_zh":"校准实验室","lab_locations":[{"code":null,"name":"PRIMA BILAVČÍK, s.r.o.","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":true,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"Uherský Brod","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"Mladá Boleslav","street":"Komenského náměstí 90/10","postal_code":"293 01","city":"Mladá Boleslav","is_hq":false,"address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","site":"29301|komenskéhonáměstí90/10"},{"code":null,"name":"Uherský Brod II","street":"Antonína Dvořáka 1274","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","site":"68801|antonínadvořáka1274"}],"lab_locations_en":[{"code":null,"name":"PRIMA BILAVČÍK, s.r.o.","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":true,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"Uherský Brod","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"Mladá Boleslav","street":"Komenského náměstí 90/10","postal_code":"293 01","city":"Mladá Boleslav","is_hq":false,"address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","site":"29301|komenskéhonáměstí90/10"},{"code":null,"name":"Uherský Brod II","street":"Antonína Dvořáka 1274","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","site":"68801|antonínadvořáka1274"}],"lab_locations_zh":[{"code":null,"name":"PRIMA BILAVČÍK, s.r.o.","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":true,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"乌赫尔斯基布罗德","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"姆拉达-博莱斯拉夫","street":"Komenského náměstí 90/10","postal_code":"293 01","city":"Mladá Boleslav","is_hq":false,"address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","site":"29301|komenskéhonáměstí90/10"},{"code":null,"name":"乌赫尔斯基布罗德 II","street":"Antonína Dvořáka 1274","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","site":"68801|antonínadvořáka1274"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"L","pl":"wymiar w metrach","en":"dimension in meters","zh":"以米为单位的尺寸","cs":"rozměr v metrech"},{"abbr":"n","pl":"liczba dwumetrowych mierzonych odcinków na całej długości","en":"number of two-metre sections along the whole length","zh":"全长上两米测量段的数量","cs":"počet dvoumetrových měřených úseků na celé délce"},{"abbr":"FS","pl":"pełny zakres (full scale)","en":"full scale","zh":"满量程（FS）","cs":"full scale (plný rozsah)"},{"abbr":"digit","pl":"rozdzielczość ostatniego miejsca","en":"last digit resolution","zh":"最后一位的分辨力","cs":"rozlišení posledního místa"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"1e02aeab23e3d9e5b9f8868ec81dfa5c7564dd016ba64d3c6b66739e9d11332c","source_pdf_url":"https://www.cai.cz/OA/pdf/622_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/622_2025_EN.pdf","has_de":true,"lab_division_de":"Kalibrierlabor","lab_locations_de":[{"code":null,"name":"PRIMA BILAVČÍK, s.r.o.","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":true,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"Uherský Brod","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"Mladá Boleslav","street":"Komenského náměstí 90/10","postal_code":"293 01","city":"Mladá Boleslav","is_hq":false,"address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","site":"29301|komenskéhonáměstí90/10"},{"code":null,"name":"Uherský Brod II","street":"Antonína Dvořáka 1274","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","site":"68801|antonínadvořáka1274"}],"lab_locations_cs":[{"code":null,"name":"PRIMA BILAVČÍK, s.r.o.","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":true,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"Uherský Brod","street":"9. května 1182","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"9. května 1182, 688 01 Uherský Brod","site":"68801|9května1182"},{"code":null,"name":"Mladá Boleslav","street":"Komenského náměstí 90/10","postal_code":"293 01","city":"Mladá Boleslav","is_hq":false,"address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","site":"29301|komenskéhonáměstí90/10"},{"code":null,"name":"Uherský Brod II","street":"Antonína Dvořáka 1274","postal_code":"688 01","city":"Uherský Brod","is_hq":false,"address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","site":"68801|antonínadvořáka1274"}]},"methods":[{"_id":"39a34ec7ee3fb5151ff6f12c","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Suwmiarki","test_object_en":"Slide gauges","test_object_zh":"卡尺","test_object_cs":"Posuvná měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 2000 mm","cmc":"(15·L +15) μm"},{"name":"rozdz. 0,01 mm","range":"od 1000 mm do 2000 mm","cmc":"(15·L +30) μm"}],"parameters_en":[{"name":"","range":"0 mm to 2000 mm","cmc":"(15·L +15) μm"},{"name":"resol. 0.01 mm","range":"1000 mm to 2000 mm","cmc":"(15·L +30) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 2000 mm","cmc":"(15·L +15) μm"},{"name":"分辨力 0,01 mm","range":"1000 mm 至 2000 mm","cmc":"(15·L +30) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 2000 mm","cmc":"(15·L +15) μm"},{"name":"rozliš. 0,01 mm","range":"1000 mm až 2000 mm","cmc":"(15·L +30) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 2000 mm CMC (15·L +15) μm\nrozdz. 0,01 mm od 1000 mm do 2000 mm CMC (15·L +30) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-01","norm_bases":["KP-PB-01"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Suwmiarki Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 2000 mm CMC (15·L +15) μm rozdz. 0,01 mm od 1000 mm do 2000 mm CMC (15·L +30) μm Posuvná měřidla Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 2000 mm CMC (15·L +15) μm rozliš. 0,01 mm 1000 mm až 2000 mm CMC (15·L +30) μm KP-PB-01 Suwmiarki Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 2000 mm CMC (15·L +15) μm rozdz. 0,01 mm od 1000 mm do 2000 mm CMC (15·L +30) μm Posuvna meridla Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 2000 mm CMC (15·L +15) μm rozlis. 0,01 mm 1000 mm az 2000 mm CMC (15·L +30) μm KP-PB-01","search_en":"Slide gauges Calibration – length Comparison with parallel gauge blocks Uherský Brod CMC for the field of measured quantity: Length Comparison with parallel gauge blocks resol. 0.01 mm KP-PB-01","search_zh":"卡尺 校准 – 长度 与量块比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与量块比较 分辨力 0,01 mm KP-PB-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 2000 mm","cmc":"(15·L +15) μm"},{"name":"Aufl. 0,01 mm","range":"von 1000 mm bis 2000 mm","cmc":"(15·L +30) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Messschieber Kalibrierung – Länge Vergleich mit Parallelendmaßen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen Aufl. 0,01 mm KP-PB-01","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Messschieber"},{"_id":"3b694138a615888368e4abd5","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Suwmiarki","test_object_en":"Slide gauges","test_object_zh":"卡尺","test_object_cs":"Posuvná měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 2000 mm","cmc":"(15·L +15) μm"},{"name":"rozdz. 0,01 mm","range":"od 1000 mm do 2000 mm","cmc":"(15·L +30) μm"}],"parameters_en":[{"name":"","range":"0 mm to 2000 mm","cmc":"(15·L +15) μm"},{"name":"resol. 0.01 mm","range":"1000 mm to 2000 mm","cmc":"(15·L +30) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 2000 mm","cmc":"(15·L +15) μm"},{"name":"分辨力 0,01 mm","range":"1000 mm 至 2000 mm","cmc":"(15·L +30) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 2000 mm","cmc":"(15·L +15) μm"},{"name":"rozliš. 0,01 mm","range":"1000 mm až 2000 mm","cmc":"(15·L +30) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 2000 mm CMC (15·L +15) μm\nrozdz. 0,01 mm od 1000 mm do 2000 mm CMC (15·L +30) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-01","norm_bases":["KP-PB-01"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Suwmiarki Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 2000 mm CMC (15·L +15) μm rozdz. 0,01 mm od 1000 mm do 2000 mm CMC (15·L +30) μm Posuvná měřidla Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 2000 mm CMC (15·L +15) μm rozliš. 0,01 mm 1000 mm až 2000 mm CMC (15·L +30) μm KP-PB-01 Suwmiarki Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 2000 mm CMC (15·L +15) μm rozdz. 0,01 mm od 1000 mm do 2000 mm CMC (15·L +30) μm Posuvna meridla Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 2000 mm CMC (15·L +15) μm rozlis. 0,01 mm 1000 mm az 2000 mm CMC (15·L +30) μm KP-PB-01","search_en":"Slide gauges Calibration – length Comparison with parallel gauge blocks Mladá Boleslav CMC for the field of measured quantity: Length Comparison with parallel gauge blocks resol. 0.01 mm KP-PB-01","search_zh":"卡尺 校准 – 长度 与量块比较 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 与量块比较 分辨力 0,01 mm KP-PB-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 2000 mm","cmc":"(15·L +15) μm"},{"name":"Aufl. 0,01 mm","range":"von 1000 mm bis 2000 mm","cmc":"(15·L +30) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Messschieber Kalibrierung – Länge Vergleich mit Parallelendmaßen Mladá Boleslav CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen Aufl. 0,01 mm KP-PB-01","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Messschieber"},{"_id":"b158c5ead71cc4db3c0edb48","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Przyrządy mikrometryczne","test_object_en":"Micrometers","test_object_zh":"测微量具","test_object_cs":"Mikrometrická měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"(15·L +1,5) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 1000 mm","cmc":"(15·L +1,5) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(15·L +1,5) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"(15·L +1,5) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC (15·L +1,5) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-02","norm_bases":["KP-PB-02"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy mikrometryczne Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 1000 mm CMC (15·L +1,5) μm Mikrometrická měřidla Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 1000 mm CMC (15·L +1,5) μm KP-PB-02 Przyrzady mikrometryczne Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 1000 mm CMC (15·L +1,5) μm Mikrometricka meridla Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 1000 mm CMC (15·L +1,5) μm KP-PB-02","search_en":"Micrometers Calibration – length Comparison with parallel gauge blocks Uherský Brod CMC for the field of measured quantity: Length Comparison with parallel gauge blocks KP-PB-02","search_zh":"测微量具 校准 – 长度 与量块比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与量块比较 KP-PB-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1000 mm","cmc":"(15·L +1,5) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Mikrometrische Messgeräte Kalibrierung – Länge Vergleich mit Parallelendmaßen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen KP-PB-02","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Mikrometrische Messgeräte"},{"_id":"a9574deea545811a8f3afcae","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Przyrządy mikrometryczne","test_object_en":"Micrometers","test_object_zh":"测微量具","test_object_cs":"Mikrometrická měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"(15·L +1,5) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 1000 mm","cmc":"(15·L +1,5) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(15·L +1,5) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"(15·L +1,5) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC (15·L +1,5) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-02","norm_bases":["KP-PB-02"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy mikrometryczne Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 1000 mm CMC (15·L +1,5) μm Mikrometrická měřidla Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 1000 mm CMC (15·L +1,5) μm KP-PB-02 Przyrzady mikrometryczne Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 1000 mm CMC (15·L +1,5) μm Mikrometricka meridla Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 1000 mm CMC (15·L +1,5) μm KP-PB-02","search_en":"Micrometers Calibration – length Comparison with parallel gauge blocks Mladá Boleslav CMC for the field of measured quantity: Length Comparison with parallel gauge blocks KP-PB-02","search_zh":"测微量具 校准 – 长度 与量块比较 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 与量块比较 KP-PB-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1000 mm","cmc":"(15·L +1,5) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Mikrometrische Messgeräte Kalibrierung – Länge Vergleich mit Parallelendmaßen Mladá Boleslav CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen KP-PB-02","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Mikrometrische Messgeräte"},{"_id":"d8fcf95ac286af36cc75e396","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"3","test_object":"Przyrządy do pomiaru długości","test_object_en":"Length gauges","test_object_zh":"长度测量器具","test_object_cs":"Měřidla délky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1040 mm","cmc":"(1,2·L +0,15) μm"}],"parameters_en":[{"name":"","range":"0 mm to 1040 mm","cmc":"(1,2·L +0,15) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1040 mm","cmc":"(1,2·L +0,15) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1040 mm","cmc":"(1,2·L +0,15) μm"}],"technique":"Pomiar bezpośredni lub porównawczy na długościomierzu","technique_en":"Direct or comparative measurement by a distance meter","technique_zh":"在测长仪上直接或比较测量","technique_cs":"Přímé, nebo porovnávací měření na délkoměru","techniques":["Pomiar bezpośredni lub porównawczy na długościomierzu"],"techniques_en":["Direct or comparative measurement by a distance meter"],"techniques_zh":["在测长仪上直接或比较测量"],"techniques_cs":["Přímé, nebo porovnávací měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1040 mm CMC (1,2·L +0,15) μm\nPomiar bezpośredni lub porównawczy na długościomierzu","reference":"KP-PB-04","norm_bases":["KP-PB-04"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru długości Wzorcowanie – długość Pomiar bezpośredni lub porównawczy na długościomierzu od 0 mm do 1040 mm CMC (1,2·L +0,15) μm Měřidla délky Kalibrace – délka Přímé, nebo porovnávací měření na délkoměru 0 mm až 1040 mm CMC (1,2·L +0,15) μm KP-PB-04 Przyrzady do pomiaru dlugosci Wzorcowanie – dlugosc Pomiar bezposredni lub porownawczy na dlugosciomierzu od 0 mm do 1040 mm CMC (1,2·L +0,15) μm Meridla delky Kalibrace – delka Prime, nebo porovnavaci mereni na delkomeru 0 mm az 1040 mm CMC (1,2·L +0,15) μm KP-PB-04","search_en":"Length gauges Calibration – length Direct or comparative measurement by a distance meter Uherský Brod CMC for the field of measured quantity: Length Direct or comparative measurement by a distance meter KP-PB-04","search_zh":"长度测量器具 校准 – 长度 在测长仪上直接或比较测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 在测长仪上直接或比较测量 KP-PB-04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1040 mm","cmc":"(1,2·L +0,15) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Längenmessgeräte Kalibrierung – Länge Direkte Messung oder Vergleichsmessung am Längenmessgerät Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung oder Vergleichsmessung am Längenmessgerät KP-PB-04","technique_de":"Direkte Messung oder Vergleichsmessung am Längenmessgerät","techniques_de":["Direkte Messung oder Vergleichsmessung am Längenmessgerät"],"test_object_de":"Längenmessgeräte"},{"_id":"1e4ad1cbbed86d97bb8b1606","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"3","test_object":"Przyrządy do pomiaru długości","test_object_en":"Length gauges","test_object_zh":"长度测量器具","test_object_cs":"Měřidla délky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1040 mm","cmc":"(1,2·L +0,15) μm"}],"parameters_en":[{"name":"","range":"0 mm to 1040 mm","cmc":"(1,2·L +0,15) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1040 mm","cmc":"(1,2·L +0,15) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1040 mm","cmc":"(1,2·L +0,15) μm"}],"technique":"Pomiar bezpośredni lub porównawczy na długościomierzu","technique_en":"Direct or comparative measurement by a distance meter","technique_zh":"在测长仪上直接或比较测量","technique_cs":"Přímé, nebo porovnávací měření na délkoměru","techniques":["Pomiar bezpośredni lub porównawczy na długościomierzu"],"techniques_en":["Direct or comparative measurement by a distance meter"],"techniques_zh":["在测长仪上直接或比较测量"],"techniques_cs":["Přímé, nebo porovnávací měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1040 mm CMC (1,2·L +0,15) μm\nPomiar bezpośredni lub porównawczy na długościomierzu","reference":"KP-PB-04","norm_bases":["KP-PB-04"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru długości Wzorcowanie – długość Pomiar bezpośredni lub porównawczy na długościomierzu od 0 mm do 1040 mm CMC (1,2·L +0,15) μm Měřidla délky Kalibrace – délka Přímé, nebo porovnávací měření na délkoměru 0 mm až 1040 mm CMC (1,2·L +0,15) μm KP-PB-04 Przyrzady do pomiaru dlugosci Wzorcowanie – dlugosc Pomiar bezposredni lub porownawczy na dlugosciomierzu od 0 mm do 1040 mm CMC (1,2·L +0,15) μm Meridla delky Kalibrace – delka Prime, nebo porovnavaci mereni na delkomeru 0 mm az 1040 mm CMC (1,2·L +0,15) μm KP-PB-04","search_en":"Length gauges Calibration – length Direct or comparative measurement by a distance meter Mladá Boleslav CMC for the field of measured quantity: Length Direct or comparative measurement by a distance meter KP-PB-04","search_zh":"长度测量器具 校准 – 长度 在测长仪上直接或比较测量 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 在测长仪上直接或比较测量 KP-PB-04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1040 mm","cmc":"(1,2·L +0,15) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Längenmessgeräte Kalibrierung – Länge Direkte Messung oder Vergleichsmessung am Längenmessgerät Mladá Boleslav CMC für den Messgrößenbereich: Länge Direkte Messung oder Vergleichsmessung am Längenmessgerät KP-PB-04","technique_de":"Direkte Messung oder Vergleichsmessung am Längenmessgerät","techniques_de":["Direkte Messung oder Vergleichsmessung am Längenmessgerät"],"test_object_de":"Längenmessgeräte"},{"_id":"d41fbd6ad22273d7cdb9660d","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Płytki wzorcowe – 3. rzędu","test_object_en":"Parallel gauge blocks - 3rd order","test_object_zh":"量块 – 3等","test_object_cs":"Koncové měrky - 3. řádu","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,5 mm do 100 mm","cmc":"(1·L +0,1) μm"}],"parameters_en":[{"name":"","range":"from 0,5 mm to 100 mm","cmc":"(1·L +0,1) μm"}],"parameters_zh":[{"name":"","range":"0,5 mm 至 100 mm","cmc":"(1·L +0,1) μm"}],"parameters_cs":[{"name":"","range":"0,5 mm až 100 mm","cmc":"(1·L +0,1) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,5 mm do 100 mm CMC (1·L +0,1) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-07","norm_bases":["KP-PB-07"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe – 3. rzędu Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0,5 mm do 100 mm CMC (1·L +0,1) μm Koncové měrky - 3. řádu Kalibrace – délka Porovnání s koncovými měrkami 0,5 mm až 100 mm CMC (1·L +0,1) μm KP-PB-07 Plytki wzorcowe – 3. rzedu Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0,5 mm do 100 mm CMC (1·L +0,1) μm Koncove merky - 3. radu Kalibrace – delka Porovnani s koncovymi merkami 0,5 mm az 100 mm CMC (1·L +0,1) μm KP-PB-07","search_en":"Parallel gauge blocks - 3rd order Calibration – length Comparison with parallel gauge blocks Uherský Brod CMC for the field of measured quantity: Length Comparison with parallel gauge blocks KP-PB-07","search_zh":"量块 – 3等 校准 – 长度 与量块比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与量块比较 KP-PB-07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0,5 mm bis 100 mm","cmc":"(1·L +0,1) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Parallelendmaße – 3. Ordnung Kalibrierung – Länge Vergleich mit Parallelendmaßen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen KP-PB-07","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Parallelendmaße – 3. Ordnung"},{"_id":"3e59e9e230418b4107e9cbfd","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Płytki wzorcowe – 4. rzędu","test_object_en":"Parallel gauge blocks - 4th order","test_object_zh":"量块 – 4等","test_object_cs":"Koncové měrky - 4. řádu","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,5 mm do 100 mm","cmc":"(2·L +0,2) μm"}],"parameters_en":[{"name":"","range":"from 0,5 mm to 100 mm","cmc":"(2·L +0,2) μm"}],"parameters_zh":[{"name":"","range":"0,5 mm 至 100 mm","cmc":"(2·L +0,2) μm"}],"parameters_cs":[{"name":"","range":"0,5 mm až 100 mm","cmc":"(2·L +0,2) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,5 mm do 100 mm CMC (2·L +0,2) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-07","norm_bases":["KP-PB-07"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe – 4. rzędu Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0,5 mm do 100 mm CMC (2·L +0,2) μm Koncové měrky - 4. řádu Kalibrace – délka Porovnání s koncovými měrkami 0,5 mm až 100 mm CMC (2·L +0,2) μm KP-PB-07 Plytki wzorcowe – 4. rzedu Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0,5 mm do 100 mm CMC (2·L +0,2) μm Koncove merky - 4. radu Kalibrace – delka Porovnani s koncovymi merkami 0,5 mm az 100 mm CMC (2·L +0,2) μm KP-PB-07","search_en":"Parallel gauge blocks - 4th order Calibration – length Comparison with parallel gauge blocks Uherský Brod CMC for the field of measured quantity: Length Comparison with parallel gauge blocks KP-PB-07","search_zh":"量块 – 4等 校准 – 长度 与量块比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与量块比较 KP-PB-07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0,5 mm bis 100 mm","cmc":"(2·L +0,2) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Parallelendmaße – 4. Ordnung Kalibrierung – Länge Vergleich mit Parallelendmaßen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen KP-PB-07","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Parallelendmaße – 4. Ordnung"},{"_id":"f96e3560f44a0ca75831861d","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Płytki wzorcowe – 4. rzędu","test_object_en":"Parallel gauge blocks - 4th order","test_object_zh":"量块 – 4等","test_object_cs":"Koncové měrky - 4. řádu","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,5 mm do 100 mm","cmc":"(2·L +0,2) μm"}],"parameters_en":[{"name":"","range":"from 0,5 mm to 100 mm","cmc":"(2·L +0,2) μm"}],"parameters_zh":[{"name":"","range":"0,5 mm 至 100 mm","cmc":"(2·L +0,2) μm"}],"parameters_cs":[{"name":"","range":"0,5 mm až 100 mm","cmc":"(2·L +0,2) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,5 mm do 100 mm CMC (2·L +0,2) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-07","norm_bases":["KP-PB-07"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe – 4. rzędu Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0,5 mm do 100 mm CMC (2·L +0,2) μm Koncové měrky - 4. řádu Kalibrace – délka Porovnání s koncovými měrkami 0,5 mm až 100 mm CMC (2·L +0,2) μm KP-PB-07 Plytki wzorcowe – 4. rzedu Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0,5 mm do 100 mm CMC (2·L +0,2) μm Koncove merky - 4. radu Kalibrace – delka Porovnani s koncovymi merkami 0,5 mm az 100 mm CMC (2·L +0,2) μm KP-PB-07","search_en":"Parallel gauge blocks - 4th order Calibration – length Comparison with parallel gauge blocks Mladá Boleslav CMC for the field of measured quantity: Length Comparison with parallel gauge blocks KP-PB-07","search_zh":"量块 – 4等 校准 – 长度 与量块比较 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 与量块比较 KP-PB-07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0,5 mm bis 100 mm","cmc":"(2·L +0,2) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Parallelendmaße – 4. Ordnung Kalibrierung – Länge Vergleich mit Parallelendmaßen Mladá Boleslav CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen KP-PB-07","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Parallelendmaße – 4. Ordnung"},{"_id":"055f15f941e0d23e4312a748","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Płytki wzorcowe – 4. rzędu","test_object_en":"Parallel gauge blocks - 4th order","test_object_zh":"量块 – 4等","test_object_cs":"Koncové měrky - 4. řádu","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 100 mm do 500 mm","cmc":"(2·L +0,2) μm"}],"parameters_en":[{"name":"","range":"from 100 mm to 500 mm","cmc":"(2·L +0,2) μm"}],"parameters_zh":[{"name":"","range":"100 mm 至 500 mm","cmc":"(2·L +0,2) μm"}],"parameters_cs":[{"name":"","range":"100 mm až 500 mm","cmc":"(2·L +0,2) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 100 mm do 500 mm CMC (2·L +0,2) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-07","norm_bases":["KP-PB-07"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe – 4. rzędu Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 100 mm do 500 mm CMC (2·L +0,2) μm Koncové měrky - 4. řádu Kalibrace – délka Porovnání s koncovými měrkami 100 mm až 500 mm CMC (2·L +0,2) μm KP-PB-07 Plytki wzorcowe – 4. rzedu Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 100 mm do 500 mm CMC (2·L +0,2) μm Koncove merky - 4. radu Kalibrace – delka Porovnani s koncovymi merkami 100 mm az 500 mm CMC (2·L +0,2) μm KP-PB-07","search_en":"Parallel gauge blocks - 4th order Calibration – length Comparison with parallel gauge blocks Mladá Boleslav CMC for the field of measured quantity: Length Comparison with parallel gauge blocks KP-PB-07","search_zh":"量块 – 4等 校准 – 长度 与量块比较 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 与量块比较 KP-PB-07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 100 mm bis 500 mm","cmc":"(2·L +0,2) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Parallelendmaße – 4. Ordnung Kalibrierung – Länge Vergleich mit Parallelendmaßen Mladá Boleslav CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen KP-PB-07","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Parallelendmaße – 4. Ordnung"},{"_id":"bef313fc763cbae287ed08ac","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Płytki wzorcowe – 4. rzędu","test_object_en":"Parallel gauge blocks - 4th order","test_object_zh":"量块 – 4等","test_object_cs":"Koncové měrky - 4. řádu","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 100 mm do 1000 mm","cmc":"(1,2·L +0,17) μm"}],"parameters_en":[{"name":"","range":"from 100 mm to 1000 mm","cmc":"(1,2·L +0,17) μm"}],"parameters_zh":[{"name":"","range":"100 mm 至 1000 mm","cmc":"(1,2·L +0,17) μm"}],"parameters_cs":[{"name":"","range":"100 mm až 1000 mm","cmc":"(1,2·L +0,17) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 100 mm do 1000 mm CMC (1,2·L +0,17) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-07","norm_bases":["KP-PB-07"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe – 4. rzędu Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 100 mm do 1000 mm CMC (1,2·L +0,17) μm Koncové měrky - 4. řádu Kalibrace – délka Porovnání s koncovými měrkami 100 mm až 1000 mm CMC (1,2·L +0,17) μm KP-PB-07 Plytki wzorcowe – 4. rzedu Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 100 mm do 1000 mm CMC (1,2·L +0,17) μm Koncove merky - 4. radu Kalibrace – delka Porovnani s koncovymi merkami 100 mm az 1000 mm CMC (1,2·L +0,17) μm KP-PB-07","search_en":"Parallel gauge blocks - 4th order Calibration – length Comparison with parallel gauge blocks Uherský Brod CMC for the field of measured quantity: Length Comparison with parallel gauge blocks KP-PB-07","search_zh":"量块 – 4等 校准 – 长度 与量块比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与量块比较 KP-PB-07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 100 mm bis 1000 mm","cmc":"(1,2·L +0,17) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Parallelendmaße – 4. Ordnung Kalibrierung – Länge Vergleich mit Parallelendmaßen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen KP-PB-07","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Parallelendmaße – 4. Ordnung"},{"_id":"e911310fdf1ffb0123a973d4","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"5","test_object":"Wysokościomierze","test_object_en":"Height gauges","test_object_zh":"高度尺","test_object_cs":"Výškoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"(1,2·L +1) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 1000 mm","cmc":"(1,2·L +1) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(1,2·L +1) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"(1,2·L +1) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC (1,2·L +1) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-12","norm_bases":["KP-PB-12"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wysokościomierze Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 1000 mm CMC (1,2·L +1) μm Výškoměry Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 1000 mm CMC (1,2·L +1) μm KP-PB-12 Wysokosciomierze Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 1000 mm CMC (1,2·L +1) μm Vyskomery Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 1000 mm CMC (1,2·L +1) μm KP-PB-12","search_en":"Height gauges Calibration – length Comparison with parallel gauge blocks Uherský Brod CMC for the field of measured quantity: Length Comparison with parallel gauge blocks KP-PB-12","search_zh":"高度尺 校准 – 长度 与量块比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与量块比较 KP-PB-12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1000 mm","cmc":"(1,2·L +1) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Höhenmessgeräte Kalibrierung – Länge Vergleich mit Parallelendmaßen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen KP-PB-12","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Höhenmessgeräte"},{"_id":"db6f094a83eba09bd97e5bc8","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"6","test_object":"Przymiary kreskowe, taśmy zwijane, taśmy miernicze","test_object_en":"Graduated scales, tape measures, measuring tapes","test_object_zh":"线纹尺、卷尺、测量带","test_object_cs":"Čárková měřítka, stáčecí metry, pásma","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 50 m","cmc":"(0,2·n) mm"}],"parameters_en":[{"name":"","range":"from 0 mm to 50 m","cmc":"(0,2·n) mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 50 m","cmc":"(0,2·n) mm"}],"parameters_cs":[{"name":"","range":"0 mm až 50 m","cmc":"(0,2·n) mm"}],"technique":"Pomiar bezpośredni na torze pomiarowym, pomiar porównawczy z taśmą wzorcową i liniałem","technique_en":"Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler","technique_zh":"在测量导轨上直接测量，与标准卷尺和直尺比较测量","technique_cs":"Přímé měření na měřicí dráze, porovnávací měření s etalonovým pásmem a pravítkem","techniques":["Pomiar bezpośredni na torze pomiarowym, pomiar porównawczy z taśmą wzorcową i liniałem"],"techniques_en":["Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler"],"techniques_zh":["在测量导轨上直接测量，与标准卷尺和直尺比较测量"],"techniques_cs":["Přímé měření na měřicí dráze, porovnávací měření s etalonovým pásmem a pravítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 50 m CMC (0,2·n) mm\nPomiar bezpośredni na torze pomiarowym, pomiar porównawczy z taśmą wzorcową i liniałem","reference":"KP-PB-14","norm_bases":["KP-PB-14"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przymiary kreskowe, taśmy zwijane, taśmy miernicze Wzorcowanie – długość Pomiar bezpośredni na torze pomiarowym, pomiar porównawczy z taśmą wzorcową i liniałem od 0 mm do 50 m CMC (0,2·n) mm Čárková měřítka, stáčecí metry, pásma Kalibrace – délka Přímé měření na měřicí dráze, porovnávací měření s etalonovým pásmem a pravítkem 0 mm až 50 m CMC (0,2·n) mm KP-PB-14 Przymiary kreskowe, tasmy zwijane, tasmy miernicze Wzorcowanie – dlugosc Pomiar bezposredni na torze pomiarowym, pomiar porownawczy z tasma wzorcowa i linialem od 0 mm do 50 m CMC (0,2·n) mm Carkova meritka, staceci metry, pasma Kalibrace – delka Prime mereni na merici draze, porovnavaci mereni s etalonovym pasmem a pravitkem 0 mm az 50 m CMC (0,2·n) mm KP-PB-14","search_en":"Graduated scales, tape measures, measuring tapes Calibration – length Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler Uherský Brod CMC for the field of measured quantity: Length Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler KP-PB-14","search_zh":"线纹尺、卷尺、测量带 校准 – 长度 在测量导轨上直接测量，与标准卷尺和直尺比较测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 在测量导轨上直接测量，与标准卷尺和直尺比较测量 KP-PB-14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 50 m","cmc":"(0,2·n) mm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Strichmaßstäbe, Rollbandmaße, Messbänder Kalibrierung – Länge Direkte Messung auf der Messbahn, Vergleichsmessung mit Referenzmessband und Lineal Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung auf der Messbahn, Vergleichsmessung mit Referenzmessband und Lineal KP-PB-14","technique_de":"Direkte Messung auf der Messbahn, Vergleichsmessung mit Referenzmessband und Lineal","techniques_de":["Direkte Messung auf der Messbahn, Vergleichsmessung mit Referenzmessband und Lineal"],"test_object_de":"Strichmaßstäbe, Rollbandmaße, Messbänder"},{"_id":"b4686effb25a61198a8f0a73","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"6","test_object":"Przymiary kreskowe, taśmy zwijane, taśmy miernicze","test_object_en":"Graduated scales, tape measures, measuring tapes","test_object_zh":"线纹尺、卷尺、测量带","test_object_cs":"Čárková měřítka, stáčecí metry, pásma","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 50 m","cmc":"(0,2·n) mm"}],"parameters_en":[{"name":"","range":"from 0 mm to 50 m","cmc":"(0,2·n) mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 50 m","cmc":"(0,2·n) mm"}],"parameters_cs":[{"name":"","range":"0 mm až 50 m","cmc":"(0,2·n) mm"}],"technique":"Pomiar bezpośredni na torze pomiarowym, pomiar porównawczy z taśmą wzorcową i liniałem","technique_en":"Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler","technique_zh":"在测量导轨上直接测量，与标准卷尺和直尺比较测量","technique_cs":"Přímé měření na měřicí dráze, porovnávací měření s etalonovým pásmem a pravítkem","techniques":["Pomiar bezpośredni na torze pomiarowym, pomiar porównawczy z taśmą wzorcową i liniałem"],"techniques_en":["Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler"],"techniques_zh":["在测量导轨上直接测量，与标准卷尺和直尺比较测量"],"techniques_cs":["Přímé měření na měřicí dráze, porovnávací měření s etalonovým pásmem a pravítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 50 m CMC (0,2·n) mm\nPomiar bezpośredni na torze pomiarowym, pomiar porównawczy z taśmą wzorcową i liniałem","reference":"KP-PB-14","norm_bases":["KP-PB-14"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przymiary kreskowe, taśmy zwijane, taśmy miernicze Wzorcowanie – długość Pomiar bezpośredni na torze pomiarowym, pomiar porównawczy z taśmą wzorcową i liniałem od 0 mm do 50 m CMC (0,2·n) mm Čárková měřítka, stáčecí metry, pásma Kalibrace – délka Přímé měření na měřicí dráze, porovnávací měření s etalonovým pásmem a pravítkem 0 mm až 50 m CMC (0,2·n) mm KP-PB-14 Przymiary kreskowe, tasmy zwijane, tasmy miernicze Wzorcowanie – dlugosc Pomiar bezposredni na torze pomiarowym, pomiar porownawczy z tasma wzorcowa i linialem od 0 mm do 50 m CMC (0,2·n) mm Carkova meritka, staceci metry, pasma Kalibrace – delka Prime mereni na merici draze, porovnavaci mereni s etalonovym pasmem a pravitkem 0 mm az 50 m CMC (0,2·n) mm KP-PB-14","search_en":"Graduated scales, tape measures, measuring tapes Calibration – length Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler Mladá Boleslav CMC for the field of measured quantity: Length Direct measurement on a measuring track, comparative measurement with reference tape measure and ruler KP-PB-14","search_zh":"线纹尺、卷尺、测量带 校准 – 长度 在测量导轨上直接测量，与标准卷尺和直尺比较测量 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 在测量导轨上直接测量，与标准卷尺和直尺比较测量 KP-PB-14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 50 m","cmc":"(0,2·n) mm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Strichmaßstäbe, Rollbandmaße, Messbänder Kalibrierung – Länge Direkte Messung auf der Messbahn, Vergleichsmessung mit Referenzmessband und Lineal Mladá Boleslav CMC für den Messgrößenbereich: Länge Direkte Messung auf der Messbahn, Vergleichsmessung mit Referenzmessband und Lineal KP-PB-14","technique_de":"Direkte Messung auf der Messbahn, Vergleichsmessung mit Referenzmessband und Lineal","techniques_de":["Direkte Messung auf der Messbahn, Vergleichsmessung mit Referenzmessband und Lineal"],"test_object_de":"Strichmaßstäbe, Rollbandmaße, Messbänder"},{"_id":"656ea16d17f8d5e0126500cf","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"7","test_object":"Długościomierze","test_object_en":"Length gauges","test_object_zh":"测长仪","test_object_cs":"Délkoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 300 mm","cmc":"(0,8·L +0,07) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 300 mm","cmc":"(0,8·L +0,07) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 300 mm","cmc":"(0,8·L +0,07) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 300 mm","cmc":"(0,8·L +0,07) μm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 300 mm CMC (0,8·L +0,07) μm\nPorównanie z płytkami wzorcowymi","reference":"KP-PB-16","norm_bases":["KP-PB-16"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długościomierze Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 300 mm CMC (0,8·L +0,07) μm Délkoměry Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 300 mm CMC (0,8·L +0,07) μm KP-PB-16 Dlugosciomierze Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 300 mm CMC (0,8·L +0,07) μm Delkomery Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 300 mm CMC (0,8·L +0,07) μm KP-PB-16","search_en":"Length gauges Calibration – length Comparison with parallel gauge blocks Uherský Brod CMC for the field of measured quantity: Length Comparison with parallel gauge blocks KP-PB-16","search_zh":"测长仪 校准 – 长度 与量块比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与量块比较 KP-PB-16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 300 mm","cmc":"(0,8·L +0,07) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Längenmessgeräte Kalibrierung – Länge Vergleich mit Parallelendmaßen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen KP-PB-16","technique_de":"Vergleich mit Parallelendmaßen","techniques_de":["Vergleich mit Parallelendmaßen"],"test_object_de":"Längenmessgeräte"},{"_id":"8d3212467619eb017d5df6c5","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"8","test_object":"Przyrządy do pomiaru długości i kształtów geometrycznych interferometrem laserowym","test_object_en":"Gauges of length and geometric shapes by a laser interferometer","test_object_zh":"用激光干涉仪测量长度和几何形状的器具","test_object_cs":"Měřidla délky a geometrických tvarů laserinterferometrem","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 20 m","cmc":"(0,8·L +0,03) μm"}],"parameters_en":[{"name":"","range":"from 0 m to 20 m","cmc":"(0,8·L +0,03) μm"}],"parameters_zh":[{"name":"","range":"0 m 至 20 m","cmc":"(0,8·L +0,03) μm"}],"parameters_cs":[{"name":"","range":"0 m až 20 m","cmc":"(0,8·L +0,03) μm"}],"technique":"Pomiar bezpośredni interferometrem laserowym","technique_en":"Direct measurement by a laser interferometer","technique_zh":"用激光干涉仪直接测量","technique_cs":"Přímé měření laserinterferometrem","techniques":["Pomiar bezpośredni interferometrem laserowym"],"techniques_en":["Direct measurement by a laser interferometer"],"techniques_zh":["用激光干涉仪直接测量"],"techniques_cs":["Přímé měření laserinterferometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 20 m CMC (0,8·L +0,03) μm\nPomiar bezpośredni interferometrem laserowym","reference":"KP-PB-19","norm_bases":["KP-PB-19"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru długości i kształtów geometrycznych interferometrem laserowym Wzorcowanie – długość Pomiar bezpośredni interferometrem laserowym od 0 m do 20 m CMC (0,8·L +0,03) μm Měřidla délky a geometrických tvarů laserinterferometrem Kalibrace – délka Přímé měření laserinterferometrem 0 m až 20 m CMC (0,8·L +0,03) μm KP-PB-19 Przyrzady do pomiaru dlugosci i ksztaltow geometrycznych interferometrem laserowym Wzorcowanie – dlugosc Pomiar bezposredni interferometrem laserowym od 0 m do 20 m CMC (0,8·L +0,03) μm Meridla delky a geometrickych tvaru laserinterferometrem Kalibrace – delka Prime mereni laserinterferometrem 0 m az 20 m CMC (0,8·L +0,03) μm KP-PB-19","search_en":"Gauges of length and geometric shapes by a laser interferometer Calibration – length Direct measurement by a laser interferometer Uherský Brod CMC for the field of measured quantity: Length Direct measurement by a laser interferometer KP-PB-19","search_zh":"用激光干涉仪测量长度和几何形状的器具 校准 – 长度 用激光干涉仪直接测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 用激光干涉仪直接测量 KP-PB-19","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 m bis 20 m","cmc":"(0,8·L +0,03) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Messgeräte für Länge und geometrische Formen mittels Laserinterferometer Kalibrierung – Länge Direkte Messung mit Laserinterferometer Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung mit Laserinterferometer KP-PB-19","technique_de":"Direkte Messung mit Laserinterferometer","techniques_de":["Direkte Messung mit Laserinterferometer"],"test_object_de":"Messgeräte für Länge und geometrische Formen mittels Laserinterferometer"},{"_id":"126e5f476444cfb1595fb188","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"9","test_object":"Przyrządy do pomiaru długości, kształtu, położeń geometrycznych i kątów interferometrem laserowym i Laser Trackerem","test_object_en":"Gauges of length, shape, geometric positions, angles with a laser interferometer and laser tracker","test_object_zh":"用激光干涉仪和激光跟踪仪测量长度、形状、几何位置和角度的器具","test_object_cs":"Měřidla délky, tvaru, geometrických poloh, úhlů laserinterferometrem a Laser Trackerem","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,2 m do 15 m","cmc":"(0,3·L +0,2) μm"}],"parameters_en":[{"name":"","range":"0,2 m to 15 m","cmc":"(0,3·L +0,2) μm"}],"parameters_zh":[{"name":"","range":"0,2 m 至 15 m","cmc":"(0,3·L +0,2) μm"}],"parameters_cs":[{"name":"","range":"0,2 m až 15 m","cmc":"(0,3·L +0,2) μm"}],"technique":"Pomiar bezpośredni interferometrem laserowym LaserTracker","technique_en":"Direct measurement by a LaserTracker laser interferometer","technique_zh":"用激光跟踪仪（LaserTracker）激光干涉仪直接测量","technique_cs":"Přímé měření laserinterferometrem LaserTracker","techniques":["Pomiar bezpośredni interferometrem laserowym LaserTracker"],"techniques_en":["Direct measurement by a LaserTracker laser interferometer"],"techniques_zh":["用激光跟踪仪（LaserTracker）激光干涉仪直接测量"],"techniques_cs":["Přímé měření laserinterferometrem LaserTracker"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,2 m do 15 m CMC (0,3·L +0,2) μm\nPomiar bezpośredni interferometrem laserowym LaserTracker","reference":"KP-PB-19","norm_bases":["KP-PB-19"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru długości, kształtu, położeń geometrycznych i kątów interferometrem laserowym i Laser Trackerem Wzorcowanie – długość Pomiar bezpośredni interferometrem laserowym LaserTracker od 0,2 m do 15 m CMC (0,3·L +0,2) μm Měřidla délky, tvaru, geometrických poloh, úhlů laserinterferometrem a Laser Trackerem Kalibrace – délka Přímé měření laserinterferometrem LaserTracker 0,2 m až 15 m CMC (0,3·L +0,2) μm KP-PB-19 Przyrzady do pomiaru dlugosci, ksztaltu, polozen geometrycznych i katow interferometrem laserowym i Laser Trackerem Wzorcowanie – dlugosc Pomiar bezposredni interferometrem laserowym LaserTracker od 0,2 m do 15 m CMC (0,3·L +0,2) μm Meridla delky, tvaru, geometrickych poloh, uhlu laserinterferometrem a Laser Trackerem Kalibrace – delka Prime mereni laserinterferometrem LaserTracker 0,2 m az 15 m CMC (0,3·L +0,2) μm KP-PB-19","search_en":"Gauges of length, shape, geometric positions, angles with a laser interferometer and laser tracker Calibration – length Direct measurement by a LaserTracker laser interferometer Uherský Brod CMC for the field of measured quantity: Length Direct measurement by a LaserTracker laser interferometer KP-PB-19","search_zh":"用激光干涉仪和激光跟踪仪测量长度、形状、几何位置和角度的器具 校准 – 长度 用激光跟踪仪（LaserTracker）激光干涉仪直接测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 用激光跟踪仪（LaserTracker）激光干涉仪直接测量 KP-PB-19","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0,2 m bis 15 m","cmc":"(0,3·L +0,2) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Messgeräte für Länge, Form, geometrische Lagen und Winkel mittels Laserinterferometer und Laser Tracker Kalibrierung – Länge Direkte Messung mit dem Laserinterferometer LaserTracker Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung mit dem Laserinterferometer LaserTracker KP-PB-19","technique_de":"Direkte Messung mit dem Laserinterferometer LaserTracker","techniques_de":["Direkte Messung mit dem Laserinterferometer LaserTracker"],"test_object_de":"Messgeräte für Länge, Form, geometrische Lagen und Winkel mittels Laserinterferometer und Laser Tracker"},{"_id":"08289e2920052b14a0246be7","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"10","test_object":"Kątowniki","test_object_en":"Angles","test_object_zh":"直角尺","test_object_cs":"Úhelníky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"4 μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 1000 mm","cmc":"4 μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"4 μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"4 μm"}],"technique":"Pomiar bezpośredni za pomocą współrzędnościowej maszyny pomiarowej","technique_en":"Direct measurement using a coordinate measuring machine","technique_zh":"用坐标测量机直接测量","technique_cs":"Přímé měření pomocí souřadnicového měřicího stroje","techniques":["Pomiar bezpośredni za pomocą współrzędnościowej maszyny pomiarowej"],"techniques_en":["Direct measurement using a coordinate measuring machine"],"techniques_zh":["用坐标测量机直接测量"],"techniques_cs":["Přímé měření pomocí souřadnicového měřicího stroje"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC 4 μm\nPomiar bezpośredni za pomocą współrzędnościowej maszyny pomiarowej","reference":"KP-PB-26","norm_bases":["KP-PB-26"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątowniki Wzorcowanie – długość Pomiar bezpośredni za pomocą współrzędnościowej maszyny pomiarowej od 0 mm do 1000 mm CMC 4 μm Úhelníky Kalibrace – délka Přímé měření pomocí souřadnicového měřicího stroje 0 mm až 1000 mm CMC 4 μm KP-PB-26 Katowniki Wzorcowanie – dlugosc Pomiar bezposredni za pomoca wspolrzednosciowej maszyny pomiarowej od 0 mm do 1000 mm CMC 4 μm Uhelniky Kalibrace – delka Prime mereni pomoci souradnicoveho mericiho stroje 0 mm az 1000 mm CMC 4 μm KP-PB-26","search_en":"Angles Calibration – length Direct measurement using a coordinate measuring machine Uherský Brod CMC for the field of measured quantity: Length Direct measurement using a coordinate measuring machine KP-PB-26","search_zh":"直角尺 校准 – 长度 用坐标测量机直接测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 用坐标测量机直接测量 KP-PB-26","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1000 mm","cmc":"4 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Anschlagwinkel Kalibrierung – Länge Direkte Messung mithilfe eines Koordinatenmessgeräts Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung mithilfe eines Koordinatenmessgeräts KP-PB-26","technique_de":"Direkte Messung mithilfe eines Koordinatenmessgeräts","techniques_de":["Direkte Messung mithilfe eines Koordinatenmessgeräts"],"test_object_de":"Anschlagwinkel"},{"_id":"aa92a2367a47799460761c2d","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"10","test_object":"Kątowniki","test_object_en":"Angles","test_object_zh":"直角尺","test_object_cs":"Úhelníky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"4 μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 1000 mm","cmc":"4 μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"4 μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"4 μm"}],"technique":"Pomiar bezpośredni za pomocą współrzędnościowej maszyny pomiarowej","technique_en":"Direct measurement using a coordinate measuring machine","technique_zh":"用坐标测量机直接测量","technique_cs":"Přímé měření pomocí souřadnicového měřicího stroje","techniques":["Pomiar bezpośredni za pomocą współrzędnościowej maszyny pomiarowej"],"techniques_en":["Direct measurement using a coordinate measuring machine"],"techniques_zh":["用坐标测量机直接测量"],"techniques_cs":["Přímé měření pomocí souřadnicového měřicího stroje"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC 4 μm\nPomiar bezpośredni za pomocą współrzędnościowej maszyny pomiarowej","reference":"KP-PB-26","norm_bases":["KP-PB-26"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątowniki Wzorcowanie – długość Pomiar bezpośredni za pomocą współrzędnościowej maszyny pomiarowej od 0 mm do 1000 mm CMC 4 μm Úhelníky Kalibrace – délka Přímé měření pomocí souřadnicového měřicího stroje 0 mm až 1000 mm CMC 4 μm KP-PB-26 Katowniki Wzorcowanie – dlugosc Pomiar bezposredni za pomoca wspolrzednosciowej maszyny pomiarowej od 0 mm do 1000 mm CMC 4 μm Uhelniky Kalibrace – delka Prime mereni pomoci souradnicoveho mericiho stroje 0 mm az 1000 mm CMC 4 μm KP-PB-26","search_en":"Angles Calibration – length Direct measurement using a coordinate measuring machine Mladá Boleslav CMC for the field of measured quantity: Length Direct measurement using a coordinate measuring machine KP-PB-26","search_zh":"直角尺 校准 – 长度 用坐标测量机直接测量 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 用坐标测量机直接测量 KP-PB-26","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1000 mm","cmc":"4 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Anschlagwinkel Kalibrierung – Länge Direkte Messung mithilfe eines Koordinatenmessgeräts Mladá Boleslav CMC für den Messgrößenbereich: Länge Direkte Messung mithilfe eines Koordinatenmessgeräts KP-PB-26","technique_de":"Direkte Messung mithilfe eines Koordinatenmessgeräts","techniques_de":["Direkte Messung mithilfe eines Koordinatenmessgeräts"],"test_object_de":"Anschlagwinkel"},{"_id":"f85e4758ea97a55e6dccf217","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"10","test_object":"Kątowniki","test_object_en":"Angles","test_object_zh":"直角尺","test_object_cs":"Úhelníky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"6 μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 1000 mm","cmc":"6 μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"6 μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"6 μm"}],"technique":"Porównanie z wzorcem prostopadłości i płytkami wzorcowymi","technique_en":"Comparison with a perpendicularity standard and parallel gauge blocks","technique_zh":"与垂直度标准器和量块比较","technique_cs":"Porovnání s etalonem kolmosti a koncovými měrkami","techniques":["Porównanie z wzorcem prostopadłości i płytkami wzorcowymi"],"techniques_en":["Comparison with a perpendicularity standard and parallel gauge blocks"],"techniques_zh":["与垂直度标准器和量块比较"],"techniques_cs":["Porovnání s etalonem kolmosti a koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC 6 μm\nPorównanie z wzorcem prostopadłości i płytkami wzorcowymi","reference":"KP-PB-26","norm_bases":["KP-PB-26"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątowniki Wzorcowanie – długość Porównanie z wzorcem prostopadłości i płytkami wzorcowymi od 0 mm do 1000 mm CMC 6 μm Úhelníky Kalibrace – délka Porovnání s etalonem kolmosti a koncovými měrkami 0 mm až 1000 mm CMC 6 μm KP-PB-26 Katowniki Wzorcowanie – dlugosc Porownanie z wzorcem prostopadlosci i plytkami wzorcowymi od 0 mm do 1000 mm CMC 6 μm Uhelniky Kalibrace – delka Porovnani s etalonem kolmosti a koncovymi merkami 0 mm az 1000 mm CMC 6 μm KP-PB-26","search_en":"Angles Calibration – length Comparison with a perpendicularity standard and parallel gauge blocks Uherský Brod CMC for the field of measured quantity: Length Comparison with a perpendicularity standard and parallel gauge blocks KP-PB-26","search_zh":"直角尺 校准 – 长度 与垂直度标准器和量块比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与垂直度标准器和量块比较 KP-PB-26","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1000 mm","cmc":"6 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Anschlagwinkel Kalibrierung – Länge Vergleich mit einem Rechtwinkligkeitsnormal und Parallelendmaßen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit einem Rechtwinkligkeitsnormal und Parallelendmaßen KP-PB-26","technique_de":"Vergleich mit einem Rechtwinkligkeitsnormal und Parallelendmaßen","techniques_de":["Vergleich mit einem Rechtwinkligkeitsnormal und Parallelendmaßen"],"test_object_de":"Anschlagwinkel"},{"_id":"73f1c48e8cbfac73d355b8a2","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"10","test_object":"Kątowniki","test_object_en":"Angles","test_object_zh":"直角尺","test_object_cs":"Úhelníky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"6 μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 1000 mm","cmc":"6 μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"6 μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"6 μm"}],"technique":"Porównanie z wzorcem prostopadłości i płytkami wzorcowymi","technique_en":"Comparison with a perpendicularity standard and parallel gauge blocks","technique_zh":"与垂直度标准器和量块比较","technique_cs":"Porovnání s etalonem kolmosti a koncovými měrkami","techniques":["Porównanie z wzorcem prostopadłości i płytkami wzorcowymi"],"techniques_en":["Comparison with a perpendicularity standard and parallel gauge blocks"],"techniques_zh":["与垂直度标准器和量块比较"],"techniques_cs":["Porovnání s etalonem kolmosti a koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC 6 μm\nPorównanie z wzorcem prostopadłości i płytkami wzorcowymi","reference":"KP-PB-26","norm_bases":["KP-PB-26"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątowniki Wzorcowanie – długość Porównanie z wzorcem prostopadłości i płytkami wzorcowymi od 0 mm do 1000 mm CMC 6 μm Úhelníky Kalibrace – délka Porovnání s etalonem kolmosti a koncovými měrkami 0 mm až 1000 mm CMC 6 μm KP-PB-26 Katowniki Wzorcowanie – dlugosc Porownanie z wzorcem prostopadlosci i plytkami wzorcowymi od 0 mm do 1000 mm CMC 6 μm Uhelniky Kalibrace – delka Porovnani s etalonem kolmosti a koncovymi merkami 0 mm az 1000 mm CMC 6 μm KP-PB-26","search_en":"Angles Calibration – length Comparison with a perpendicularity standard and parallel gauge blocks Mladá Boleslav CMC for the field of measured quantity: Length Comparison with a perpendicularity standard and parallel gauge blocks KP-PB-26","search_zh":"直角尺 校准 – 长度 与垂直度标准器和量块比较 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 与垂直度标准器和量块比较 KP-PB-26","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1000 mm","cmc":"6 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Anschlagwinkel Kalibrierung – Länge Vergleich mit einem Rechtwinkligkeitsnormal und Parallelendmaßen Mladá Boleslav CMC für den Messgrößenbereich: Länge Vergleich mit einem Rechtwinkligkeitsnormal und Parallelendmaßen KP-PB-26","technique_de":"Vergleich mit einem Rechtwinkligkeitsnormal und Parallelendmaßen","techniques_de":["Vergleich mit einem Rechtwinkligkeitsnormal und Parallelendmaßen"],"test_object_de":"Anschlagwinkel"},{"_id":"3b58488b44a814d99514b927","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"11","test_object":"Średnicówki","test_object_en":"Internal gauges","test_object_zh":"内径表","test_object_cs":"Dutinoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 300 mm","cmc":"(3·L +2) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 300 mm","cmc":"(3·L +2) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 300 mm","cmc":"(3·L +2) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 300 mm","cmc":"(3·L +2) μm"}],"technique":"Porównanie z pierścieniami nastawczymi","technique_en":"Comparison with setting rings","technique_zh":"与校对环规比较","technique_cs":"Porovnání s nastavovacími kroužky","techniques":["Porównanie z pierścieniami nastawczymi"],"techniques_en":["Comparison with setting rings"],"techniques_zh":["与校对环规比较"],"techniques_cs":["Porovnání s nastavovacími kroužky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 300 mm CMC (3·L +2) μm\nPorównanie z pierścieniami nastawczymi","reference":"KP-PB-20","norm_bases":["KP-PB-20"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Średnicówki Wzorcowanie – długość Porównanie z pierścieniami nastawczymi od 0 mm do 300 mm CMC (3·L +2) μm Dutinoměry Kalibrace – délka Porovnání s nastavovacími kroužky 0 mm až 300 mm CMC (3·L +2) μm KP-PB-20 Srednicowki Wzorcowanie – dlugosc Porownanie z pierscieniami nastawczymi od 0 mm do 300 mm CMC (3·L +2) μm Dutinomery Kalibrace – delka Porovnani s nastavovacimi krouzky 0 mm az 300 mm CMC (3·L +2) μm KP-PB-20","search_en":"Internal gauges Calibration – length Comparison with setting rings Uherský Brod CMC for the field of measured quantity: Length Comparison with setting rings KP-PB-20","search_zh":"内径表 校准 – 长度 与校对环规比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与校对环规比较 KP-PB-20","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 300 mm","cmc":"(3·L +2) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Innenmessgeräte Kalibrierung – Länge Vergleich mit Einstellringen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Einstellringen KP-PB-20","technique_de":"Vergleich mit Einstellringen","techniques_de":["Vergleich mit Einstellringen"],"test_object_de":"Innenmessgeräte"},{"_id":"416101ed112421f58df31f67","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"11","test_object":"Średnicówki","test_object_en":"Internal gauges","test_object_zh":"内径表","test_object_cs":"Dutinoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 300 mm","cmc":"(3·L +2) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 300 mm","cmc":"(3·L +2) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 300 mm","cmc":"(3·L +2) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 300 mm","cmc":"(3·L +2) μm"}],"technique":"Porównanie z pierścieniami nastawczymi","technique_en":"Comparison with setting rings","technique_zh":"与校对环规比较","technique_cs":"Porovnání s nastavovacími kroužky","techniques":["Porównanie z pierścieniami nastawczymi"],"techniques_en":["Comparison with setting rings"],"techniques_zh":["与校对环规比较"],"techniques_cs":["Porovnání s nastavovacími kroužky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 300 mm CMC (3·L +2) μm\nPorównanie z pierścieniami nastawczymi","reference":"KP-PB-20","norm_bases":["KP-PB-20"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Średnicówki Wzorcowanie – długość Porównanie z pierścieniami nastawczymi od 0 mm do 300 mm CMC (3·L +2) μm Dutinoměry Kalibrace – délka Porovnání s nastavovacími kroužky 0 mm až 300 mm CMC (3·L +2) μm KP-PB-20 Srednicowki Wzorcowanie – dlugosc Porownanie z pierscieniami nastawczymi od 0 mm do 300 mm CMC (3·L +2) μm Dutinomery Kalibrace – delka Porovnani s nastavovacimi krouzky 0 mm az 300 mm CMC (3·L +2) μm KP-PB-20","search_en":"Internal gauges Calibration – length Comparison with setting rings Mladá Boleslav CMC for the field of measured quantity: Length Comparison with setting rings KP-PB-20","search_zh":"内径表 校准 – 长度 与校对环规比较 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 与校对环规比较 KP-PB-20","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 300 mm","cmc":"(3·L +2) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Innenmessgeräte Kalibrierung – Länge Vergleich mit Einstellringen Mladá Boleslav CMC für den Messgrößenbereich: Länge Vergleich mit Einstellringen KP-PB-20","technique_de":"Vergleich mit Einstellringen","techniques_de":["Vergleich mit Einstellringen"],"test_object_de":"Innenmessgeräte"},{"_id":"4ae0d6af47c58559accc9785","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"12","test_object":"Współrzędnościowe maszyny pomiarowe stykowe, optyczne, wieloczujnikowe","test_object_en":"Contact, optical, multisensor coordinate measuring machines","test_object_zh":"接触式、光学式、多传感器坐标测量机","test_object_cs":"Souřadnicové měřicí stroje dotykové, optické, multisenzorové","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1600 mm","cmc":"(0,6·L +0,2) μm"}],"parameters_en":[{"name":"","range":"0 mm to 1600 mm","cmc":"(0,6·L +0,2) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1600 mm","cmc":"(0,6·L +0,2) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1600 mm","cmc":"(0,6·L +0,2) μm"}],"technique":"Porównanie z płytkami wzorcowymi i przymiarem kreskowym","technique_en":"Comparison with steel parallels and graduated scale","technique_zh":"与量块和线纹尺比较","technique_cs":"Porovnání s koncovými měrkami a čárkovým měřítkem","techniques":["Porównanie z płytkami wzorcowymi i przymiarem kreskowym"],"techniques_en":["Comparison with steel parallels and graduated scale"],"techniques_zh":["与量块和线纹尺比较"],"techniques_cs":["Porovnání s koncovými měrkami a čárkovým měřítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1600 mm CMC (0,6·L +0,2) μm\nPorównanie z płytkami wzorcowymi i przymiarem kreskowym","reference":"KP-PB-21","norm_bases":["KP-PB-21"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe stykowe, optyczne, wieloczujnikowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi i przymiarem kreskowym od 0 mm do 1600 mm CMC (0,6·L +0,2) μm Souřadnicové měřicí stroje dotykové, optické, multisenzorové Kalibrace – délka Porovnání s koncovými měrkami a čárkovým měřítkem 0 mm až 1600 mm CMC (0,6·L +0,2) μm KP-PB-21 Wspolrzednosciowe maszyny pomiarowe stykowe, optyczne, wieloczujnikowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi i przymiarem kreskowym od 0 mm do 1600 mm CMC (0,6·L +0,2) μm Souradnicove merici stroje dotykove, opticke, multisenzorove Kalibrace – delka Porovnani s koncovymi merkami a carkovym meritkem 0 mm az 1600 mm CMC (0,6·L +0,2) μm KP-PB-21","search_en":"Contact, optical, multisensor coordinate measuring machines Calibration – length Comparison with steel parallels and graduated scale Uherský Brod CMC for the field of measured quantity: Length Comparison with steel parallels and graduated scale KP-PB-21","search_zh":"接触式、光学式、多传感器坐标测量机 校准 – 长度 与量块和线纹尺比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与量块和线纹尺比较 KP-PB-21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1600 mm","cmc":"(0,6·L +0,2) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Taktile, optische, Multisensor-Koordinatenmessgeräte Kalibrierung – Länge Vergleich mit Parallelendmaßen und Strichmaßstab Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Parallelendmaßen und Strichmaßstab KP-PB-21","technique_de":"Vergleich mit Parallelendmaßen und Strichmaßstab","techniques_de":["Vergleich mit Parallelendmaßen und Strichmaßstab"],"test_object_de":"Taktile, optische, Multisensor-Koordinatenmessgeräte"},{"_id":"a186df8f9af47f8ef724a4ee","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"13","test_object":"Współrzędnościowe maszyny pomiarowe – ręczne przenośne ramiona przegubowe","test_object_en":"Coordinate measuring machines – manual mobile hinged arms","test_object_zh":"坐标测量机 – 手动便携式关节臂","test_object_cs":"Souřadnicové měřicí stroje – manuální mobilní kloubová ramena","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 3700 mm","cmc":"(2·L +20) μm"}],"parameters_en":[{"name":"","range":"0 mm to 3700 mm","cmc":"(2·L +20) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 3700 mm","cmc":"(2·L +20) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 3700 mm","cmc":"(2·L +20) μm"}],"technique":"Porównanie z wzorcami schodkowymi","technique_en":"Comparison using step gauges","technique_zh":"与阶梯规比较","technique_cs":"Porovnání se stupňovými měrkami","techniques":["Porównanie z wzorcami schodkowymi"],"techniques_en":["Comparison using step gauges"],"techniques_zh":["与阶梯规比较"],"techniques_cs":["Porovnání se stupňovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 3700 mm CMC (2·L +20) μm\nPorównanie z wzorcami schodkowymi","reference":"KP-PB-21","norm_bases":["KP-PB-21"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe – ręczne przenośne ramiona przegubowe Wzorcowanie – długość Porównanie z wzorcami schodkowymi od 0 mm do 3700 mm CMC (2·L +20) μm Souřadnicové měřicí stroje – manuální mobilní kloubová ramena Kalibrace – délka Porovnání se stupňovými měrkami 0 mm až 3700 mm CMC (2·L +20) μm KP-PB-21 Wspolrzednosciowe maszyny pomiarowe – reczne przenosne ramiona przegubowe Wzorcowanie – dlugosc Porownanie z wzorcami schodkowymi od 0 mm do 3700 mm CMC (2·L +20) μm Souradnicove merici stroje – manualni mobilni kloubova ramena Kalibrace – delka Porovnani se stupnovymi merkami 0 mm az 3700 mm CMC (2·L +20) μm KP-PB-21","search_en":"Coordinate measuring machines – manual mobile hinged arms Calibration – length Comparison using step gauges Uherský Brod CMC for the field of measured quantity: Length Comparison using step gauges KP-PB-21","search_zh":"坐标测量机 – 手动便携式关节臂 校准 – 长度 与阶梯规比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与阶梯规比较 KP-PB-21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 3700 mm","cmc":"(2·L +20) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Koordinatenmessgeräte – manuelle tragbare Gelenkarme Kalibrierung – Länge Vergleich mit Stufenendmaßen Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Stufenendmaßen KP-PB-21","technique_de":"Vergleich mit Stufenendmaßen","techniques_de":["Vergleich mit Stufenendmaßen"],"test_object_de":"Koordinatenmessgeräte – manuelle tragbare Gelenkarme"},{"_id":"ebbe255a7cb56f00e692ae5c","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"14","test_object":"Współrzędnościowe maszyny pomiarowe – skanery bezstykowe","test_object_en":"Coordinate measuring machines – proximity scanners","test_object_zh":"坐标测量机 – 非接触式扫描仪","test_object_cs":"Souřadnicové měřicí stroje – bezdotykové skenery","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 200 mm","cmc":"3 μm"},{"name":"","range":"od 200 mm do 1500 mm","cmc":"20 μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 200 mm","cmc":"3 μm"},{"name":"","range":"200 mm to 1500 mm","cmc":"20 μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 200 mm","cmc":"3 μm"},{"name":"","range":"200 mm 至 1500 mm","cmc":"20 μm"}],"parameters_cs":[{"name":"","range":"0 mm až 200 mm","cmc":"3 μm"},{"name":"","range":"200 mm až 1500 mm","cmc":"20 μm"}],"technique":"Porównanie z szablonem pomiarowym","technique_en":"Comparison with a measuring gauge","technique_zh":"与测量样板比较","technique_cs":"Porovnání s měřicí šablonou","techniques":["Porównanie z szablonem pomiarowym"],"techniques_en":["Comparison with a measuring gauge"],"techniques_zh":["与测量样板比较"],"techniques_cs":["Porovnání s měřicí šablonou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 200 mm CMC 3 μm\nod 200 mm do 1500 mm CMC 20 μm\nPorównanie z szablonem pomiarowym","reference":"KP-PB-21","norm_bases":["KP-PB-21"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe – skanery bezstykowe Wzorcowanie – długość Porównanie z szablonem pomiarowym od 0 mm do 200 mm CMC 3 μm od 200 mm do 1500 mm CMC 20 μm Souřadnicové měřicí stroje – bezdotykové skenery Kalibrace – délka Porovnání s měřicí šablonou 0 mm až 200 mm CMC 3 μm 200 mm až 1500 mm CMC 20 μm KP-PB-21 Wspolrzednosciowe maszyny pomiarowe – skanery bezstykowe Wzorcowanie – dlugosc Porownanie z szablonem pomiarowym od 0 mm do 200 mm CMC 3 μm od 200 mm do 1500 mm CMC 20 μm Souradnicove merici stroje – bezdotykove skenery Kalibrace – delka Porovnani s merici sablonou 0 mm az 200 mm CMC 3 μm 200 mm az 1500 mm CMC 20 μm KP-PB-21","search_en":"Coordinate measuring machines – proximity scanners Calibration – length Comparison with a measuring gauge Uherský Brod CMC for the field of measured quantity: Length Comparison with a measuring gauge KP-PB-21","search_zh":"坐标测量机 – 非接触式扫描仪 校准 – 长度 与测量样板比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与测量样板比较 KP-PB-21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 200 mm","cmc":"3 μm"},{"name":"","range":"von 200 mm bis 1500 mm","cmc":"20 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Koordinatenmessgeräte – berührungslose Scanner Kalibrierung – Länge Vergleich mit einer Messlehre Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit einer Messlehre KP-PB-21","technique_de":"Vergleich mit einer Messlehre","techniques_de":["Vergleich mit einer Messlehre"],"test_object_de":"Koordinatenmessgeräte – berührungslose Scanner"},{"_id":"30d4d5ad7dffdd31d05a87ec","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"15","test_object":"Współrzędnościowe maszyny pomiarowe","test_object_en":"Coordinate measuring machines","test_object_zh":"坐标测量机","test_object_cs":"Souřadnicové měřicí stroje","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 30 m","cmc":"50 μm"}],"parameters_en":[{"name":"","range":"from 0 m to 30 m","cmc":"50 μm"}],"parameters_zh":[{"name":"","range":"0 m 至 30 m","cmc":"50 μm"}],"parameters_cs":[{"name":"","range":"0 m až 30 m","cmc":"50 μm"}],"technique":"Pomiar bezpośredni interferometrem laserowym LaserTracker","technique_en":"Direct measurement by a LaserTracker laser interferometer","technique_zh":"用激光跟踪仪（LaserTracker）激光干涉仪直接测量","technique_cs":"Přímé měření laserinterferometrem LaserTracker","techniques":["Pomiar bezpośredni interferometrem laserowym LaserTracker"],"techniques_en":["Direct measurement by a LaserTracker laser interferometer"],"techniques_zh":["用激光跟踪仪（LaserTracker）激光干涉仪直接测量"],"techniques_cs":["Přímé měření laserinterferometrem LaserTracker"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 30 m CMC 50 μm\nPomiar bezpośredni interferometrem laserowym LaserTracker","reference":"KP-PB-21","norm_bases":["KP-PB-21"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe Wzorcowanie – długość Pomiar bezpośredni interferometrem laserowym LaserTracker od 0 m do 30 m CMC 50 μm Souřadnicové měřicí stroje Kalibrace – délka Přímé měření laserinterferometrem LaserTracker 0 m až 30 m CMC 50 μm KP-PB-21 Wspolrzednosciowe maszyny pomiarowe Wzorcowanie – dlugosc Pomiar bezposredni interferometrem laserowym LaserTracker od 0 m do 30 m CMC 50 μm Souradnicove merici stroje Kalibrace – delka Prime mereni laserinterferometrem LaserTracker 0 m az 30 m CMC 50 μm KP-PB-21","search_en":"Coordinate measuring machines Calibration – length Direct measurement by a LaserTracker laser interferometer Uherský Brod CMC for the field of measured quantity: Length Direct measurement by a LaserTracker laser interferometer KP-PB-21","search_zh":"坐标测量机 校准 – 长度 用激光跟踪仪（LaserTracker）激光干涉仪直接测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 用激光跟踪仪（LaserTracker）激光干涉仪直接测量 KP-PB-21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 m bis 30 m","cmc":"50 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Koordinatenmessgeräte Kalibrierung – Länge Direkte Messung mit dem Laserinterferometer LaserTracker Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung mit dem Laserinterferometer LaserTracker KP-PB-21","technique_de":"Direkte Messung mit dem Laserinterferometer LaserTracker","techniques_de":["Direkte Messung mit dem Laserinterferometer LaserTracker"],"test_object_de":"Koordinatenmessgeräte"},{"_id":"97ade1aa3c9fcef8faaa8345","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"16","test_object":"Współrzędnościowe maszyny pomiarowe – tomografy","test_object_en":"Coordinate measuring machines – tomographs","test_object_zh":"坐标测量机 – 断层扫描仪","test_object_cs":"Souřadnicové měřicí stroje – tomografy","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 500 mm","cmc":"3 μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 500 mm","cmc":"3 μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 500 mm","cmc":"3 μm"}],"parameters_cs":[{"name":"","range":"0 mm až 500 mm","cmc":"3 μm"}],"technique":"Porównanie z wzorcem kulowym","technique_en":"Comparison with a spherical standard","technique_zh":"与球形标准器比较","technique_cs":"Porovnání s kulovým normálem","techniques":["Porównanie z wzorcem kulowym"],"techniques_en":["Comparison with a spherical standard"],"techniques_zh":["与球形标准器比较"],"techniques_cs":["Porovnání s kulovým normálem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 500 mm CMC 3 μm\nPorównanie z wzorcem kulowym","reference":"KP-PB-21","norm_bases":["KP-PB-21"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe – tomografy Wzorcowanie – długość Porównanie z wzorcem kulowym od 0 mm do 500 mm CMC 3 μm Souřadnicové měřicí stroje – tomografy Kalibrace – délka Porovnání s kulovým normálem 0 mm až 500 mm CMC 3 μm KP-PB-21 Wspolrzednosciowe maszyny pomiarowe – tomografy Wzorcowanie – dlugosc Porownanie z wzorcem kulowym od 0 mm do 500 mm CMC 3 μm Souradnicove merici stroje – tomografy Kalibrace – delka Porovnani s kulovym normalem 0 mm az 500 mm CMC 3 μm KP-PB-21","search_en":"Coordinate measuring machines – tomographs Calibration – length Comparison with a spherical standard Uherský Brod CMC for the field of measured quantity: Length Comparison with a spherical standard KP-PB-21","search_zh":"坐标测量机 – 断层扫描仪 校准 – 长度 与球形标准器比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与球形标准器比较 KP-PB-21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 500 mm","cmc":"3 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Koordinatenmessgeräte – Tomographen Kalibrierung – Länge Vergleich mit einem Kugelnormal Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit einem Kugelnormal KP-PB-21","technique_de":"Vergleich mit einem Kugelnormal","techniques_de":["Vergleich mit einem Kugelnormal"],"test_object_de":"Koordinatenmessgeräte – Tomographen"},{"_id":"0a122ee61e562502daac49b3","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"17","test_object":"Wzorce chropowatości powierzchni","test_object_en":"Surface roughness standards","test_object_zh":"表面粗糙度标准器","test_object_cs":"Etalony drsnosti povrchu","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,01 μm do 100 μm","cmc":"(0,06·L) μm"}],"parameters_en":[{"name":"","range":"0,01 μm to 100 μm","cmc":"(0,06·L) μm"}],"parameters_zh":[{"name":"","range":"0,01 μm 至 100 μm","cmc":"(0,06·L) μm"}],"parameters_cs":[{"name":"","range":"0,01 μm až 100 μm","cmc":"(0,06·L) μm"}],"technique":"Pomiar bezpośredni chropowatościomierzem","technique_en":"Direct measurement by a roughness meter","technique_zh":"用粗糙度仪直接测量","technique_cs":"Přímé měření drsnoměrem","techniques":["Pomiar bezpośredni chropowatościomierzem"],"techniques_en":["Direct measurement by a roughness meter"],"techniques_zh":["用粗糙度仪直接测量"],"techniques_cs":["Přímé měření drsnoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,01 μm do 100 μm CMC (0,06·L) μm\nPomiar bezpośredni chropowatościomierzem","reference":"KP-PB-23","norm_bases":["KP-PB-23"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorce chropowatości powierzchni Wzorcowanie – długość Pomiar bezpośredni chropowatościomierzem od 0,01 μm do 100 μm CMC (0,06·L) μm Etalony drsnosti povrchu Kalibrace – délka Přímé měření drsnoměrem 0,01 μm až 100 μm CMC (0,06·L) μm KP-PB-23 Wzorce chropowatosci powierzchni Wzorcowanie – dlugosc Pomiar bezposredni chropowatosciomierzem od 0,01 μm do 100 μm CMC (0,06·L) μm Etalony drsnosti povrchu Kalibrace – delka Prime mereni drsnomerem 0,01 μm az 100 μm CMC (0,06·L) μm KP-PB-23","search_en":"Surface roughness standards Calibration – length Direct measurement by a roughness meter Uherský Brod CMC for the field of measured quantity: Length Direct measurement by a roughness meter KP-PB-23","search_zh":"表面粗糙度标准器 校准 – 长度 用粗糙度仪直接测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 用粗糙度仪直接测量 KP-PB-23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0,01 μm bis 100 μm","cmc":"(0,06·L) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Oberflächenrauheitsnormale Kalibrierung – Länge Direkte Messung mit Rauheitsmessgerät Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung mit Rauheitsmessgerät KP-PB-23","technique_de":"Direkte Messung mit Rauheitsmessgerät","techniques_de":["Direkte Messung mit Rauheitsmessgerät"],"test_object_de":"Oberflächenrauheitsnormale"},{"_id":"629503ecd082399d071a63d7","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"18","test_object":"Chropowatościomierze","test_object_en":"Roughness meters","test_object_zh":"粗糙度仪","test_object_cs":"Drsnoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,01 μm do 100 μm","cmc":"(0,035·L) μm"}],"parameters_en":[{"name":"","range":"0,01 μm to 100 μm","cmc":"(0,035·L) μm"}],"parameters_zh":[{"name":"","range":"0,01 μm 至 100 μm","cmc":"(0,035·L) μm"}],"parameters_cs":[{"name":"","range":"0,01 μm až 100 μm","cmc":"(0,035·L) μm"}],"technique":"Porównanie z wzorcem chropowatości","technique_en":"Comparison with a roughness standard","technique_zh":"与粗糙度标准器比较","technique_cs":"Porovnání s etalonem drsnosti","techniques":["Porównanie z wzorcem chropowatości"],"techniques_en":["Comparison with a roughness standard"],"techniques_zh":["与粗糙度标准器比较"],"techniques_cs":["Porovnání s etalonem drsnosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,01 μm do 100 μm CMC (0,035·L) μm\nPorównanie z wzorcem chropowatości","reference":"KP-PB-24","norm_bases":["KP-PB-24"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Chropowatościomierze Wzorcowanie – długość Porównanie z wzorcem chropowatości od 0,01 μm do 100 μm CMC (0,035·L) μm Drsnoměry Kalibrace – délka Porovnání s etalonem drsnosti 0,01 μm až 100 μm CMC (0,035·L) μm KP-PB-24 Chropowatosciomierze Wzorcowanie – dlugosc Porownanie z wzorcem chropowatosci od 0,01 μm do 100 μm CMC (0,035·L) μm Drsnomery Kalibrace – delka Porovnani s etalonem drsnosti 0,01 μm az 100 μm CMC (0,035·L) μm KP-PB-24","search_en":"Roughness meters Calibration – length Comparison with a roughness standard Uherský Brod CMC for the field of measured quantity: Length Comparison with a roughness standard KP-PB-24","search_zh":"粗糙度仪 校准 – 长度 与粗糙度标准器比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与粗糙度标准器比较 KP-PB-24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0,01 μm bis 100 μm","cmc":"(0,035·L) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Rauheitsmessgeräte Kalibrierung – Länge Vergleich mit Rauheitsnormal Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit Rauheitsnormal KP-PB-24","technique_de":"Vergleich mit Rauheitsnormal","techniques_de":["Vergleich mit Rauheitsnormal"],"test_object_de":"Rauheitsmessgeräte"},{"_id":"7d8df555f1399bf17cfef49e","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"19","test_object":"Przyrządy do pomiaru okrągłości","test_object_en":"Ring gauges","test_object_zh":"圆度仪","test_object_cs":"Kruhoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"okrągłość","range":"od 0 μm do 2000 μm","cmc":"0,1 μm"}],"parameters_en":[{"name":"roundness","range":"0 μm to 2000 μm","cmc":"0,1 μm"}],"parameters_zh":[{"name":"圆度","range":"0 μm 至 2000 μm","cmc":"0,1 μm"}],"parameters_cs":[{"name":"kruhovitost","range":"0 μm až 2000 μm","cmc":"0,1 μm"}],"technique":"Porównanie z kulą wzorcową","technique_en":"Comparison with a reference sphere","technique_zh":"与标准球比较","technique_cs":"Porovnání s etalonovou koulí","techniques":["Porównanie z kulą wzorcową"],"techniques_en":["Comparison with a reference sphere"],"techniques_zh":["与标准球比较"],"techniques_cs":["Porovnání s etalonovou koulí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nokrągłość od 0 μm do 2000 μm CMC 0,1 μm\nPorównanie z kulą wzorcową","reference":"KP-PB-31","norm_bases":["KP-PB-31"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru okrągłości Wzorcowanie – długość Porównanie z kulą wzorcową okrągłość od 0 μm do 2000 μm CMC 0,1 μm Kruhoměry Kalibrace – délka Porovnání s etalonovou koulí kruhovitost 0 μm až 2000 μm CMC 0,1 μm KP-PB-31 Przyrzady do pomiaru okraglosci Wzorcowanie – dlugosc Porownanie z kula wzorcowa okraglosc od 0 μm do 2000 μm CMC 0,1 μm Kruhomery Kalibrace – delka Porovnani s etalonovou kouli kruhovitost 0 μm az 2000 μm CMC 0,1 μm KP-PB-31","search_en":"Ring gauges Calibration – length Comparison with a reference sphere Uherský Brod CMC for the field of measured quantity: Length Comparison with a reference sphere roundness KP-PB-31","search_zh":"圆度仪 校准 – 长度 与标准球比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与标准球比较 圆度 KP-PB-31","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"Rundheit","range":"von 0 μm bis 2000 μm","cmc":"0,1 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Formmessgeräte für Rundheit Kalibrierung – Länge Vergleich mit einer Referenzkugel Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit einer Referenzkugel Rundheit KP-PB-31","technique_de":"Vergleich mit einer Referenzkugel","techniques_de":["Vergleich mit einer Referenzkugel"],"test_object_de":"Formmessgeräte für Rundheit"},{"_id":"9e15ea5d9af9a15b52c419da","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"19","test_object":"Przyrządy do pomiaru okrągłości","test_object_en":"Ring gauges","test_object_zh":"圆度仪","test_object_cs":"Kruhoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"prostoliniowość","range":"od 0 μm do 2000 μm","cmc":"0,11 μm"}],"parameters_en":[{"name":"straightness","range":"0 μm to 2000 μm","cmc":"0,11 μm"}],"parameters_zh":[{"name":"直线度","range":"0 μm 至 2000 μm","cmc":"0,11 μm"}],"parameters_cs":[{"name":"přímost","range":"0 μm až 2000 μm","cmc":"0,11 μm"}],"technique":"Porównanie z płytką płaską szklaną","technique_en":"Comparison with a flat glass","technique_zh":"与平晶比较","technique_cs":"Porovnání s rovinným sklem","techniques":["Porównanie z płytką płaską szklaną"],"techniques_en":["Comparison with a flat glass"],"techniques_zh":["与平晶比较"],"techniques_cs":["Porovnání s rovinným sklem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nprostoliniowość od 0 μm do 2000 μm CMC 0,11 μm\nPorównanie z płytką płaską szklaną","reference":"KP-PB-31","norm_bases":["KP-PB-31"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru okrągłości Wzorcowanie – długość Porównanie z płytką płaską szklaną prostoliniowość od 0 μm do 2000 μm CMC 0,11 μm Kruhoměry Kalibrace – délka Porovnání s rovinným sklem přímost 0 μm až 2000 μm CMC 0,11 μm KP-PB-31 Przyrzady do pomiaru okraglosci Wzorcowanie – dlugosc Porownanie z plytka plaska szklana prostoliniowosc od 0 μm do 2000 μm CMC 0,11 μm Kruhomery Kalibrace – delka Porovnani s rovinnym sklem primost 0 μm az 2000 μm CMC 0,11 μm KP-PB-31","search_en":"Ring gauges Calibration – length Comparison with a flat glass Uherský Brod CMC for the field of measured quantity: Length Comparison with a flat glass straightness KP-PB-31","search_zh":"圆度仪 校准 – 长度 与平晶比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与平晶比较 直线度 KP-PB-31","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"Geradheit","range":"von 0 μm bis 2000 μm","cmc":"0,11 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Formmessgeräte für Rundheit Kalibrierung – Länge Vergleich mit einer planparallelen Glasplatte Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit einer planparallelen Glasplatte Geradheit KP-PB-31","technique_de":"Vergleich mit einer planparallelen Glasplatte","techniques_de":["Vergleich mit einer planparallelen Glasplatte"],"test_object_de":"Formmessgeräte für Rundheit"},{"_id":"2612cbef1e60b3d37c32562e","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"21","test_object":"Profilometry","test_object_en":"Profilometers","test_object_zh":"轮廓仪","test_object_cs":"Profiloměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 600 mm","cmc":"(1,0·L +1,2) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 600 mm","cmc":"(1,0·L +1,2) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 600 mm","cmc":"(1,0·L +1,2) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 600 mm","cmc":"(1,0·L +1,2) μm"}],"technique":"Porównanie z wzorcem konturu","technique_en":"Comparison with a contour standard","technique_zh":"与轮廓标准器比较","technique_cs":"Porovnání s etalonem kontury","techniques":["Porównanie z wzorcem konturu"],"techniques_en":["Comparison with a contour standard"],"techniques_zh":["与轮廓标准器比较"],"techniques_cs":["Porovnání s etalonem kontury"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 600 mm CMC (1,0·L +1,2) μm\nPorównanie z wzorcem konturu","reference":"KP-PB-25","norm_bases":["KP-PB-25"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Profilometry Wzorcowanie – długość Porównanie z wzorcem konturu od 0 mm do 600 mm CMC (1,0·L +1,2) μm Profiloměry Kalibrace – délka Porovnání s etalonem kontury 0 mm až 600 mm CMC (1,0·L +1,2) μm KP-PB-25 Profilometry Wzorcowanie – dlugosc Porownanie z wzorcem konturu od 0 mm do 600 mm CMC (1,0·L +1,2) μm Profilomery Kalibrace – delka Porovnani s etalonem kontury 0 mm az 600 mm CMC (1,0·L +1,2) μm KP-PB-25","search_en":"Profilometers Calibration – length Comparison with a contour standard Uherský Brod CMC for the field of measured quantity: Length Comparison with a contour standard KP-PB-25","search_zh":"轮廓仪 校准 – 长度 与轮廓标准器比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 与轮廓标准器比较 KP-PB-25","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 600 mm","cmc":"(1,0·L +1,2) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Profilometer Kalibrierung – Länge Vergleich mit einem Konturnormal Uherský Brod CMC für den Messgrößenbereich: Länge Vergleich mit einem Konturnormal KP-PB-25","technique_de":"Vergleich mit einem Konturnormal","techniques_de":["Vergleich mit einem Konturnormal"],"test_object_de":"Profilometer"},{"_id":"8297de35a4679c5ff0ff002d","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"22","test_object":"Przyrządy do pomiaru długości i wielkości geometrycznych","test_object_en":"Gauges of length and geometric quantities","test_object_zh":"长度和几何量测量器具","test_object_cs":"Měřidla délky a geometrických veličin","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"(3·L +0,5) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 1000 mm","cmc":"(3·L +0,5) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(3·L +0,5) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"(3·L +0,5) μm"}],"technique":"Pomiar bezpośredni współrzędnościową maszyną pomiarową","technique_en":"Direct measurement by a coordinate measuring machine","technique_zh":"用坐标测量机直接测量","technique_cs":"Přímé měření souřadnicovým měřicím strojem","techniques":["Pomiar bezpośredni współrzędnościową maszyną pomiarową"],"techniques_en":["Direct measurement by a coordinate measuring machine"],"techniques_zh":["用坐标测量机直接测量"],"techniques_cs":["Přímé měření souřadnicovým měřicím strojem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC (3·L +0,5) μm\nPomiar bezpośredni współrzędnościową maszyną pomiarową","reference":"KP-PB-27","norm_bases":["KP-PB-27"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru długości i wielkości geometrycznych Wzorcowanie – długość Pomiar bezpośredni współrzędnościową maszyną pomiarową od 0 mm do 1000 mm CMC (3·L +0,5) μm Měřidla délky a geometrických veličin Kalibrace – délka Přímé měření souřadnicovým měřicím strojem 0 mm až 1000 mm CMC (3·L +0,5) μm KP-PB-27 Przyrzady do pomiaru dlugosci i wielkosci geometrycznych Wzorcowanie – dlugosc Pomiar bezposredni wspolrzednosciowa maszyna pomiarowa od 0 mm do 1000 mm CMC (3·L +0,5) μm Meridla delky a geometrickych velicin Kalibrace – delka Prime mereni souradnicovym mericim strojem 0 mm az 1000 mm CMC (3·L +0,5) μm KP-PB-27","search_en":"Gauges of length and geometric quantities Calibration – length Direct measurement by a coordinate measuring machine Uherský Brod CMC for the field of measured quantity: Length Direct measurement by a coordinate measuring machine KP-PB-27","search_zh":"长度和几何量测量器具 校准 – 长度 用坐标测量机直接测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 用坐标测量机直接测量 KP-PB-27","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1000 mm","cmc":"(3·L +0,5) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Messgeräte für Länge und geometrische Größen Kalibrierung – Länge Direkte Messung mit einem Koordinatenmessgerät Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung mit einem Koordinatenmessgerät KP-PB-27","technique_de":"Direkte Messung mit einem Koordinatenmessgerät","techniques_de":["Direkte Messung mit einem Koordinatenmessgerät"],"test_object_de":"Messgeräte für Länge und geometrische Größen"},{"_id":"72d5d4bd4e58de10e5946a0f","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"22","test_object":"Przyrządy do pomiaru długości i wielkości geometrycznych","test_object_en":"Gauges of length and geometric quantities","test_object_zh":"长度和几何量测量器具","test_object_cs":"Měřidla délky a geometrických veličin","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"(3·L +0,5) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 1000 mm","cmc":"(3·L +0,5) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(3·L +0,5) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"(3·L +0,5) μm"}],"technique":"Pomiar bezpośredni współrzędnościową maszyną pomiarową","technique_en":"Direct measurement by a coordinate measuring machine","technique_zh":"用坐标测量机直接测量","technique_cs":"Přímé měření souřadnicovým měřicím strojem","techniques":["Pomiar bezpośredni współrzędnościową maszyną pomiarową"],"techniques_en":["Direct measurement by a coordinate measuring machine"],"techniques_zh":["用坐标测量机直接测量"],"techniques_cs":["Přímé měření souřadnicovým měřicím strojem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC (3·L +0,5) μm\nPomiar bezpośredni współrzędnościową maszyną pomiarową","reference":"KP-PB-27","norm_bases":["KP-PB-27"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru długości i wielkości geometrycznych Wzorcowanie – długość Pomiar bezpośredni współrzędnościową maszyną pomiarową od 0 mm do 1000 mm CMC (3·L +0,5) μm Měřidla délky a geometrických veličin Kalibrace – délka Přímé měření souřadnicovým měřicím strojem 0 mm až 1000 mm CMC (3·L +0,5) μm KP-PB-27 Przyrzady do pomiaru dlugosci i wielkosci geometrycznych Wzorcowanie – dlugosc Pomiar bezposredni wspolrzednosciowa maszyna pomiarowa od 0 mm do 1000 mm CMC (3·L +0,5) μm Meridla delky a geometrickych velicin Kalibrace – delka Prime mereni souradnicovym mericim strojem 0 mm az 1000 mm CMC (3·L +0,5) μm KP-PB-27","search_en":"Gauges of length and geometric quantities Calibration – length Direct measurement by a coordinate measuring machine Mladá Boleslav CMC for the field of measured quantity: Length Direct measurement by a coordinate measuring machine KP-PB-27","search_zh":"长度和几何量测量器具 校准 – 长度 用坐标测量机直接测量 姆拉达-博莱斯拉夫 被测量领域的CMC：长度 用坐标测量机直接测量 KP-PB-27","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 1000 mm","cmc":"(3·L +0,5) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Messgeräte für Länge und geometrische Größen Kalibrierung – Länge Direkte Messung mit einem Koordinatenmessgerät Mladá Boleslav CMC für den Messgrößenbereich: Länge Direkte Messung mit einem Koordinatenmessgerät KP-PB-27","technique_de":"Direkte Messung mit einem Koordinatenmessgerät","techniques_de":["Direkte Messung mit einem Koordinatenmessgerät"],"test_object_de":"Messgeräte für Länge und geometrische Größen"},{"_id":"d0d785d78afc47243567347f","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"22","test_object":"Przyrządy do pomiaru długości i wielkości geometrycznych","test_object_en":"Gauges of length and geometric quantities","test_object_zh":"长度和几何量测量器具","test_object_cs":"Měřidla délky a geometrických veličin","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 300 mm","cmc":"(1,2·L +0,2) μm"}],"parameters_en":[{"name":"","range":"from 0 mm to 300 mm","cmc":"(1,2·L +0,2) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 300 mm","cmc":"(1,2·L +0,2) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 300 mm","cmc":"(1,2·L +0,2) μm"}],"technique":"Pomiar bezpośredni na przyrządzie do pomiaru okrągłości","technique_en":"Direct measurement by a ring gauge","technique_zh":"在圆度仪上直接测量","technique_cs":"Přímé měření na kruhoměru","techniques":["Pomiar bezpośredni na przyrządzie do pomiaru okrągłości"],"techniques_en":["Direct measurement by a ring gauge"],"techniques_zh":["在圆度仪上直接测量"],"techniques_cs":["Přímé měření na kruhoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 300 mm CMC (1,2·L +0,2) μm\nPomiar bezpośredni na przyrządzie do pomiaru okrągłości","reference":"KP-PB-27","norm_bases":["KP-PB-27"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru długości i wielkości geometrycznych Wzorcowanie – długość Pomiar bezpośredni na przyrządzie do pomiaru okrągłości od 0 mm do 300 mm CMC (1,2·L +0,2) μm Měřidla délky a geometrických veličin Kalibrace – délka Přímé měření na kruhoměru 0 mm až 300 mm CMC (1,2·L +0,2) μm KP-PB-27 Przyrzady do pomiaru dlugosci i wielkosci geometrycznych Wzorcowanie – dlugosc Pomiar bezposredni na przyrzadzie do pomiaru okraglosci od 0 mm do 300 mm CMC (1,2·L +0,2) μm Meridla delky a geometrickych velicin Kalibrace – delka Prime mereni na kruhomeru 0 mm az 300 mm CMC (1,2·L +0,2) μm KP-PB-27","search_en":"Gauges of length and geometric quantities Calibration – length Direct measurement by a ring gauge Uherský Brod CMC for the field of measured quantity: Length Direct measurement by a ring gauge KP-PB-27","search_zh":"长度和几何量测量器具 校准 – 长度 在圆度仪上直接测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 在圆度仪上直接测量 KP-PB-27","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 300 mm","cmc":"(1,2·L +0,2) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Messgeräte für Länge und geometrische Größen Kalibrierung – Länge Direkte Messung am Formmessgerät für Rundheit Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung am Formmessgerät für Rundheit KP-PB-27","technique_de":"Direkte Messung am Formmessgerät für Rundheit","techniques_de":["Direkte Messung am Formmessgerät für Rundheit"],"test_object_de":"Messgeräte für Länge und geometrische Größen"},{"_id":"db00da8afd976d0b1937517d","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"23","test_object":"Przyrządy 3D do pomiaru długości","test_object_en":"3D length gauges","test_object_zh":"三维长度测量器具","test_object_cs":"3D měřidla délky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 3200 mm","cmc":"43 μm"}],"parameters_en":[{"name":"","range":"0 mm to 3200 mm","cmc":"43 μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 3200 mm","cmc":"43 μm"}],"parameters_cs":[{"name":"","range":"0 mm až 3200 mm","cmc":"43 μm"}],"technique":"Pomiar bezpośredni przenośnym ramieniem przegubowym","technique_en":"Direct measurement by a mobile hinged arm","technique_zh":"用便携式关节臂直接测量","technique_cs":"Přímé měření mobilním kloubovým ramenem","techniques":["Pomiar bezpośredni przenośnym ramieniem przegubowym"],"techniques_en":["Direct measurement by a mobile hinged arm"],"techniques_zh":["用便携式关节臂直接测量"],"techniques_cs":["Přímé měření mobilním kloubovým ramenem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 3200 mm CMC 43 μm\nPomiar bezpośredni przenośnym ramieniem przegubowym","reference":"KP-PB-27","norm_bases":["KP-PB-27"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy 3D do pomiaru długości Wzorcowanie – długość Pomiar bezpośredni przenośnym ramieniem przegubowym od 0 mm do 3200 mm CMC 43 μm 3D měřidla délky Kalibrace – délka Přímé měření mobilním kloubovým ramenem 0 mm až 3200 mm CMC 43 μm KP-PB-27 Przyrzady 3D do pomiaru dlugosci Wzorcowanie – dlugosc Pomiar bezposredni przenosnym ramieniem przegubowym od 0 mm do 3200 mm CMC 43 μm 3D meridla delky Kalibrace – delka Prime mereni mobilnim kloubovym ramenem 0 mm az 3200 mm CMC 43 μm KP-PB-27","search_en":"3D length gauges Calibration – length Direct measurement by a mobile hinged arm Uherský Brod CMC for the field of measured quantity: Length Direct measurement by a mobile hinged arm KP-PB-27","search_zh":"三维长度测量器具 校准 – 长度 用便携式关节臂直接测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 用便携式关节臂直接测量 KP-PB-27","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 3200 mm","cmc":"43 μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"3D-Längenmessgeräte Kalibrierung – Länge Direkte Messung mit einem tragbaren Gelenkarm Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung mit einem tragbaren Gelenkarm KP-PB-27","technique_de":"Direkte Messung mit einem tragbaren Gelenkarm","techniques_de":["Direkte Messung mit einem tragbaren Gelenkarm"],"test_object_de":"3D-Längenmessgeräte"},{"_id":"1297caa6b0eb42968988f032","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"24","test_object":"Dalmierze laserowe","test_object_en":"Laser distance meters","test_object_zh":"激光测距仪","test_object_cs":"Laserové dálkoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 20 m","cmc":"0,9 mm"}],"parameters_en":[{"name":"","range":"from 0 m to 20 m","cmc":"0,9 mm"}],"parameters_zh":[{"name":"","range":"0 m 至 20 m","cmc":"0,9 mm"}],"parameters_cs":[{"name":"","range":"0 m až 20 m","cmc":"0,9 mm"}],"technique":"Pomiar bezpośredni interferometrem laserowym LaserTracker, porównanie z wzorcem długości","technique_en":"Direct measurement by a LaserTracker laser interferometer, comparison with a length standard","technique_zh":"用激光跟踪仪（LaserTracker）激光干涉仪直接测量，与长度标准器比较","technique_cs":"Přímé měření laserinterferometrem LaserTracker, porovnání s etalonem délky","techniques":["Pomiar bezpośredni interferometrem laserowym LaserTracker, porównanie z wzorcem długości"],"techniques_en":["Direct measurement by a LaserTracker laser interferometer, comparison with a length standard"],"techniques_zh":["用激光跟踪仪（LaserTracker）激光干涉仪直接测量，与长度标准器比较"],"techniques_cs":["Přímé měření laserinterferometrem LaserTracker, porovnání s etalonem délky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 20 m CMC 0,9 mm\nPomiar bezpośredni interferometrem laserowym LaserTracker, porównanie z wzorcem długości","reference":"KP-PB-28","norm_bases":["KP-PB-28"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Dalmierze laserowe Wzorcowanie – długość Pomiar bezpośredni interferometrem laserowym LaserTracker, porównanie z wzorcem długości od 0 m do 20 m CMC 0,9 mm Laserové dálkoměry Kalibrace – délka Přímé měření laserinterferometrem LaserTracker, porovnání s etalonem délky 0 m až 20 m CMC 0,9 mm KP-PB-28 Dalmierze laserowe Wzorcowanie – dlugosc Pomiar bezposredni interferometrem laserowym LaserTracker, porownanie z wzorcem dlugosci od 0 m do 20 m CMC 0,9 mm Laserove dalkomery Kalibrace – delka Prime mereni laserinterferometrem LaserTracker, porovnani s etalonem delky 0 m az 20 m CMC 0,9 mm KP-PB-28","search_en":"Laser distance meters Calibration – length Direct measurement by a LaserTracker laser interferometer, comparison with a length standard Uherský Brod CMC for the field of measured quantity: Length Direct measurement by a LaserTracker laser interferometer, comparison with a length standard KP-PB-28","search_zh":"激光测距仪 校准 – 长度 用激光跟踪仪（LaserTracker）激光干涉仪直接测量，与长度标准器比较 乌赫尔斯基布罗德 被测量领域的CMC：长度 用激光跟踪仪（LaserTracker）激光干涉仪直接测量，与长度标准器比较 KP-PB-28","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 m bis 20 m","cmc":"0,9 mm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Laserentfernungsmesser Kalibrierung – Länge Direkte Messung mit dem Laserinterferometer LaserTracker, Vergleich mit einem Längennormal Uherský Brod CMC für den Messgrößenbereich: Länge Direkte Messung mit dem Laserinterferometer LaserTracker, Vergleich mit einem Längennormal KP-PB-28","technique_de":"Direkte Messung mit dem Laserinterferometer LaserTracker, Vergleich mit einem Längennormal","techniques_de":["Direkte Messung mit dem Laserinterferometer LaserTracker, Vergleich mit einem Längennormal"],"test_object_de":"Laserentfernungsmesser"},{"_id":"8ebfddab0fd6091e9839483f","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"25","test_object":"Grubościomierze powłok","test_object_en":"Surface layer thickness gauges","test_object_zh":"覆层测厚仪","test_object_cs":"Tloušťkoměry povrchových vrstev","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 2,0 mm","cmc":"(20·L +1,3) μm"}],"parameters_en":[{"name":"","range":"0 mm to 2,0 mm","cmc":"(20·L +1,3) μm"}],"parameters_zh":[{"name":"","range":"0 mm 至 2,0 mm","cmc":"(20·L +1,3) μm"}],"parameters_cs":[{"name":"","range":"0 mm až 2,0 mm","cmc":"(20·L +1,3) μm"}],"technique":"Pomiar porównawczy z wzorcem grubości","technique_en":"Comparative measurement by a thickness standard","technique_zh":"与厚度标准器比较测量","technique_cs":"Porovnávací měření s etalonem tloušťky","techniques":["Pomiar porównawczy z wzorcem grubości"],"techniques_en":["Comparative measurement by a thickness standard"],"techniques_zh":["与厚度标准器比较测量"],"techniques_cs":["Porovnávací měření s etalonem tloušťky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 2,0 mm CMC (20·L +1,3) μm\nPomiar porównawczy z wzorcem grubości","reference":"KP-PB-29","norm_bases":["KP-PB-29"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grubościomierze powłok Wzorcowanie – długość Pomiar porównawczy z wzorcem grubości od 0 mm do 2,0 mm CMC (20·L +1,3) μm Tloušťkoměry povrchových vrstev Kalibrace – délka Porovnávací měření s etalonem tloušťky 0 mm až 2,0 mm CMC (20·L +1,3) μm KP-PB-29 Grubosciomierze powlok Wzorcowanie – dlugosc Pomiar porownawczy z wzorcem grubosci od 0 mm do 2,0 mm CMC (20·L +1,3) μm Tloustkomery povrchovych vrstev Kalibrace – delka Porovnavaci mereni s etalonem tloustky 0 mm az 2,0 mm CMC (20·L +1,3) μm KP-PB-29","search_en":"Surface layer thickness gauges Calibration – length Comparative measurement by a thickness standard Uherský Brod CMC for the field of measured quantity: Length Comparative measurement by a thickness standard KP-PB-29","search_zh":"覆层测厚仪 校准 – 长度 与厚度标准器比较测量 乌赫尔斯基布罗德 被测量领域的CMC：长度 与厚度标准器比较测量 KP-PB-29","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Länge","parameters_de":[{"name":"","range":"von 0 mm bis 2,0 mm","cmc":"(20·L +1,3) μm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Länge","search_de":"Schichtdickenmessgeräte Kalibrierung – Länge Vergleichsmessung mit Dickennormal Uherský Brod CMC für den Messgrößenbereich: Länge Vergleichsmessung mit Dickennormal KP-PB-29","technique_de":"Vergleichsmessung mit Dickennormal","techniques_de":["Vergleichsmessung mit Dickennormal"],"test_object_de":"Schichtdickenmessgeräte"},{"_id":"67b07363478596c4da860f45","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Kątomierze","test_object_en":"Angle gauges","test_object_zh":"量角器","test_object_cs":"Úhloměry","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0 ° do 360 °","cmc":"3´"}],"parameters_en":[{"name":"","range":"from 0 ° to 360 °","cmc":"3´"}],"parameters_zh":[{"name":"","range":"0 ° 至 360 °","cmc":"3´"}],"parameters_cs":[{"name":"","range":"0 ° až 360 °","cmc":"3´"}],"technique":"Porównanie z płytkami kątowymi","technique_en":"Comparison with angle gauges","technique_zh":"与角度量块比较","technique_cs":"Porovnání s úhlovými měrkami","techniques":["Porównanie z płytkami kątowymi"],"techniques_en":["Comparison with angle gauges"],"techniques_zh":["与角度量块比较"],"techniques_cs":["Porovnání s úhlovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0 ° do 360 ° CMC 3´\nPorównanie z płytkami kątowymi","reference":"KP-PB-15","norm_bases":["KP-PB-15"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątomierze Wzorcowanie – kąt płaski Porównanie z płytkami kątowymi od 0 ° do 360 ° CMC 3´ Úhloměry Kalibrace – rovinný úhel Porovnání s úhlovými měrkami 0 ° až 360 ° CMC 3´ KP-PB-15 Katomierze Wzorcowanie – kat plaski Porownanie z plytkami katowymi od 0 ° do 360 ° CMC 3´ Uhlomery Kalibrace – rovinny uhel Porovnani s uhlovymi merkami 0 ° az 360 ° CMC 3´ KP-PB-15","search_en":"Angle gauges Calibration – plane angle Comparison with angle gauges Uherský Brod CMC for the field of measured quantity: Plane angle Comparison with angle gauges KP-PB-15","search_zh":"量角器 校准 – 平面角 与角度量块比较 乌赫尔斯基布罗德 被测量领域的CMC：平面角 与角度量块比较 KP-PB-15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – ebener Winkel","parameters_de":[{"name":"","range":"von 0 ° bis 360 °","cmc":"3´"}],"regulatory_area_de":"CMC für den Messgrößenbereich: ebener Winkel","search_de":"Winkelmesser Kalibrierung – ebener Winkel Vergleich mit Winkelendmaßen Uherský Brod CMC für den Messgrößenbereich: ebener Winkel Vergleich mit Winkelendmaßen KP-PB-15","technique_de":"Vergleich mit Winkelendmaßen","techniques_de":["Vergleich mit Winkelendmaßen"],"test_object_de":"Winkelmesser"},{"_id":"082e90c7d8464f64e5c02e17","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Kątomierze","test_object_en":"Angle gauges","test_object_zh":"量角器","test_object_cs":"Úhloměry","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0 ° do 360 °","cmc":"3´"}],"parameters_en":[{"name":"","range":"from 0 ° to 360 °","cmc":"3´"}],"parameters_zh":[{"name":"","range":"0 ° 至 360 °","cmc":"3´"}],"parameters_cs":[{"name":"","range":"0 ° až 360 °","cmc":"3´"}],"technique":"Porównanie z płytkami kątowymi","technique_en":"Comparison with angle gauges","technique_zh":"与角度量块比较","technique_cs":"Porovnání s úhlovými měrkami","techniques":["Porównanie z płytkami kątowymi"],"techniques_en":["Comparison with angle gauges"],"techniques_zh":["与角度量块比较"],"techniques_cs":["Porovnání s úhlovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0 ° do 360 ° CMC 3´\nPorównanie z płytkami kątowymi","reference":"KP-PB-15","norm_bases":["KP-PB-15"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątomierze Wzorcowanie – kąt płaski Porównanie z płytkami kątowymi od 0 ° do 360 ° CMC 3´ Úhloměry Kalibrace – rovinný úhel Porovnání s úhlovými měrkami 0 ° až 360 ° CMC 3´ KP-PB-15 Katomierze Wzorcowanie – kat plaski Porownanie z plytkami katowymi od 0 ° do 360 ° CMC 3´ Uhlomery Kalibrace – rovinny uhel Porovnani s uhlovymi merkami 0 ° az 360 ° CMC 3´ KP-PB-15","search_en":"Angle gauges Calibration – plane angle Comparison with angle gauges Mladá Boleslav CMC for the field of measured quantity: Plane angle Comparison with angle gauges KP-PB-15","search_zh":"量角器 校准 – 平面角 与角度量块比较 姆拉达-博莱斯拉夫 被测量领域的CMC：平面角 与角度量块比较 KP-PB-15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – ebener Winkel","parameters_de":[{"name":"","range":"von 0 ° bis 360 °","cmc":"3´"}],"regulatory_area_de":"CMC für den Messgrößenbereich: ebener Winkel","search_de":"Winkelmesser Kalibrierung – ebener Winkel Vergleich mit Winkelendmaßen Mladá Boleslav CMC für den Messgrößenbereich: ebener Winkel Vergleich mit Winkelendmaßen KP-PB-15","technique_de":"Vergleich mit Winkelendmaßen","techniques_de":["Vergleich mit Winkelendmaßen"],"test_object_de":"Winkelmesser"},{"_id":"5cf1365fa054a7b17eabd9a4","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Poziomnice murarskie","test_object_en":"Builder's levels","test_object_zh":"建筑水平尺","test_object_cs":"Libely zednické","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od -3 ° do 3 °","cmc":"0,7 mm/m"}],"parameters_en":[{"name":"","range":"-3 ° to 3 °","cmc":"0,7 mm/m"}],"parameters_zh":[{"name":"","range":"-3 ° 至 3 °","cmc":"0,7 mm/m"}],"parameters_cs":[{"name":"","range":"-3 ° až 3 °","cmc":"0,7 mm/m"}],"technique":"Pomiar bezpośredni na podzielnicy, porównanie z wzorcem kąta","technique_en":"Direct measurement on an index head, comparison with an angle gauge","technique_zh":"在分度头上直接测量，与角度标准器比较","technique_cs":"Přímé měření na dělicí hlavě, Porovnání s etalonem úhlu","techniques":["Pomiar bezpośredni na podzielnicy, porównanie z wzorcem kąta"],"techniques_en":["Direct measurement on an index head, comparison with an angle gauge"],"techniques_zh":["在分度头上直接测量，与角度标准器比较"],"techniques_cs":["Přímé měření na dělicí hlavě, Porovnání s etalonem úhlu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod -3 ° do 3 ° CMC 0,7 mm/m\nPomiar bezpośredni na podzielnicy, porównanie z wzorcem kąta","reference":"KP-PB-36","norm_bases":["KP-PB-36"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Poziomnice murarskie Wzorcowanie – kąt płaski Pomiar bezpośredni na podzielnicy, porównanie z wzorcem kąta od -3 ° do 3 ° CMC 0,7 mm/m Libely zednické Kalibrace – rovinný úhel Přímé měření na dělicí hlavě, Porovnání s etalonem úhlu -3 ° až 3 ° CMC 0,7 mm/m KP-PB-36 Poziomnice murarskie Wzorcowanie – kat plaski Pomiar bezposredni na podzielnicy, porownanie z wzorcem kata od -3 ° do 3 ° CMC 0,7 mm/m Libely zednicke Kalibrace – rovinny uhel Prime mereni na delici hlave, Porovnani s etalonem uhlu -3 ° az 3 ° CMC 0,7 mm/m KP-PB-36","search_en":"Builder's levels Calibration – plane angle Direct measurement on an index head, comparison with an angle gauge Uherský Brod CMC for the field of measured quantity: Plane angle Direct measurement on an index head, comparison with an angle gauge KP-PB-36","search_zh":"建筑水平尺 校准 – 平面角 在分度头上直接测量，与角度标准器比较 乌赫尔斯基布罗德 被测量领域的CMC：平面角 在分度头上直接测量，与角度标准器比较 KP-PB-36","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – ebener Winkel","parameters_de":[{"name":"","range":"von -3 ° bis 3 °","cmc":"0,7 mm/m"}],"regulatory_area_de":"CMC für den Messgrößenbereich: ebener Winkel","search_de":"Maurerwasserwaagen Kalibrierung – ebener Winkel Direkte Messung am Teilkopf, Vergleich mit einem Winkelnormal Uherský Brod CMC für den Messgrößenbereich: ebener Winkel Direkte Messung am Teilkopf, Vergleich mit einem Winkelnormal KP-PB-36","technique_de":"Direkte Messung am Teilkopf, Vergleich mit einem Winkelnormal","techniques_de":["Direkte Messung am Teilkopf, Vergleich mit einem Winkelnormal"],"test_object_de":"Maurerwasserwaagen"},{"_id":"af60a913c8c9f9ffd713e00f","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Pochyłomierze","test_object_en":"Clinometers","test_object_zh":"倾角仪","test_object_cs":"Sklonoměry","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od -180 ° do 180 °","cmc":"0,15°"}],"parameters_en":[{"name":"","range":"from -180 ° to 180 °","cmc":"0,15°"}],"parameters_zh":[{"name":"","range":"-180 ° 至 180 °","cmc":"0,15°"}],"parameters_cs":[{"name":"","range":"-180 ° až 180 °","cmc":"0,15°"}],"technique":"Pomiar bezpośredni na podzielnicy, porównanie z wzorcem kąta","technique_en":"Direct measurement on an index head, comparison with an angle gauge","technique_zh":"在分度头上直接测量，与角度标准器比较","technique_cs":"Přímé měření na dělicí hlavě, Porovnání s etalonem úhlu","techniques":["Pomiar bezpośredni na podzielnicy, porównanie z wzorcem kąta"],"techniques_en":["Direct measurement on an index head, comparison with an angle gauge"],"techniques_zh":["在分度头上直接测量，与角度标准器比较"],"techniques_cs":["Přímé měření na dělicí hlavě, Porovnání s etalonem úhlu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod -180 ° do 180 ° CMC 0,15°\nPomiar bezpośredni na podzielnicy, porównanie z wzorcem kąta","reference":"KP-PB-36","norm_bases":["KP-PB-36"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pochyłomierze Wzorcowanie – kąt płaski Pomiar bezpośredni na podzielnicy, porównanie z wzorcem kąta od -180 ° do 180 ° CMC 0,15° Sklonoměry Kalibrace – rovinný úhel Přímé měření na dělicí hlavě, Porovnání s etalonem úhlu -180 ° až 180 ° CMC 0,15° KP-PB-36 Pochylomierze Wzorcowanie – kat plaski Pomiar bezposredni na podzielnicy, porownanie z wzorcem kata od -180 ° do 180 ° CMC 0,15° Sklonomery Kalibrace – rovinny uhel Prime mereni na delici hlave, Porovnani s etalonem uhlu -180 ° az 180 ° CMC 0,15° KP-PB-36","search_en":"Clinometers Calibration – plane angle Direct measurement on an index head, comparison with an angle gauge Uherský Brod CMC for the field of measured quantity: Plane angle Direct measurement on an index head, comparison with an angle gauge KP-PB-36","search_zh":"倾角仪 校准 – 平面角 在分度头上直接测量，与角度标准器比较 乌赫尔斯基布罗德 被测量领域的CMC：平面角 在分度头上直接测量，与角度标准器比较 KP-PB-36","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – ebener Winkel","parameters_de":[{"name":"","range":"von -180 ° bis 180 °","cmc":"0,15°"}],"regulatory_area_de":"CMC für den Messgrößenbereich: ebener Winkel","search_de":"Neigungsmesser Kalibrierung – ebener Winkel Direkte Messung am Teilkopf, Vergleich mit einem Winkelnormal Uherský Brod CMC für den Messgrößenbereich: ebener Winkel Direkte Messung am Teilkopf, Vergleich mit einem Winkelnormal KP-PB-36","technique_de":"Direkte Messung am Teilkopf, Vergleich mit einem Winkelnormal","techniques_de":["Direkte Messung am Teilkopf, Vergleich mit einem Winkelnormal"],"test_object_de":"Neigungsmesser"},{"_id":"79662e7b6e6a994be42eda4c","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"3","test_object":"Kąt obrotu klucza dynamometrycznego","test_object_en":"Rotation angle of torque wrench","test_object_zh":"扭矩扳手转角","test_object_cs":"Úhel natočení momentového klíče","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0 ° do 270 °","cmc":"0,32°"}],"parameters_en":[{"name":"","range":"0 ° to 270 °","cmc":"0,32°"}],"parameters_zh":[{"name":"","range":"0 ° 至 270 °","cmc":"0,32°"}],"parameters_cs":[{"name":"","range":"0 ° až 270 °","cmc":"0,32°"}],"technique":"Pomiar bezpośredni za pomocą czujnika momentu i kąta","technique_en":"Direct measurement by an angle sensor","technique_zh":"用扭矩角度传感器直接测量","technique_cs":"Přímé měření pomocí snímače momentu úhlu","techniques":["Pomiar bezpośredni za pomocą czujnika momentu i kąta"],"techniques_en":["Direct measurement by an angle sensor"],"techniques_zh":["用扭矩角度传感器直接测量"],"techniques_cs":["Přímé měření pomocí snímače momentu úhlu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0 ° do 270 ° CMC 0,32°\nPomiar bezpośredni za pomocą czujnika momentu i kąta","reference":"KP-PB-40","norm_bases":["KP-PB-40"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt obrotu klucza dynamometrycznego Wzorcowanie – kąt płaski Pomiar bezpośredni za pomocą czujnika momentu i kąta od 0 ° do 270 ° CMC 0,32° Úhel natočení momentového klíče Kalibrace – rovinný úhel Přímé měření pomocí snímače momentu úhlu 0 ° až 270 ° CMC 0,32° KP-PB-40 Kat obrotu klucza dynamometrycznego Wzorcowanie – kat plaski Pomiar bezposredni za pomoca czujnika momentu i kata od 0 ° do 270 ° CMC 0,32° Uhel natoceni momentoveho klice Kalibrace – rovinny uhel Prime mereni pomoci snimace momentu uhlu 0 ° az 270 ° CMC 0,32° KP-PB-40","search_en":"Rotation angle of torque wrench Calibration – plane angle Direct measurement by an angle sensor Uherský Brod CMC for the field of measured quantity: Plane angle Direct measurement by an angle sensor KP-PB-40","search_zh":"扭矩扳手转角 校准 – 平面角 用扭矩角度传感器直接测量 乌赫尔斯基布罗德 被测量领域的CMC：平面角 用扭矩角度传感器直接测量 KP-PB-40","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – ebener Winkel","parameters_de":[{"name":"","range":"von 0 ° bis 270 °","cmc":"0,32°"}],"regulatory_area_de":"CMC für den Messgrößenbereich: ebener Winkel","search_de":"Drehwinkel des Drehmomentschlüssels Kalibrierung – ebener Winkel Direkte Messung mit einem Drehmoment- und Drehwinkelsensor Uherský Brod CMC für den Messgrößenbereich: ebener Winkel Direkte Messung mit einem Drehmoment- und Drehwinkelsensor KP-PB-40","technique_de":"Direkte Messung mit einem Drehmoment- und Drehwinkelsensor","techniques_de":["Direkte Messung mit einem Drehmoment- und Drehwinkelsensor"],"test_object_de":"Drehwinkel des Drehmomentschlüssels"},{"_id":"8f12d51643b59c29918329f8","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"3","test_object":"Kąt obrotu klucza dynamometrycznego","test_object_en":"Rotation angle of torque wrench","test_object_zh":"扭矩扳手转角","test_object_cs":"Úhel natočení momentového klíče","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0 ° do 270 °","cmc":"0,32°"}],"parameters_en":[{"name":"","range":"0 ° to 270 °","cmc":"0,32°"}],"parameters_zh":[{"name":"","range":"0 ° 至 270 °","cmc":"0,32°"}],"parameters_cs":[{"name":"","range":"0 ° až 270 °","cmc":"0,32°"}],"technique":"Pomiar bezpośredni za pomocą czujnika momentu i kąta","technique_en":"Direct measurement by an angle sensor","technique_zh":"用扭矩角度传感器直接测量","technique_cs":"Přímé měření pomocí snímače momentu úhlu","techniques":["Pomiar bezpośredni za pomocą czujnika momentu i kąta"],"techniques_en":["Direct measurement by an angle sensor"],"techniques_zh":["用扭矩角度传感器直接测量"],"techniques_cs":["Přímé měření pomocí snímače momentu úhlu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0 ° do 270 ° CMC 0,32°\nPomiar bezpośredni za pomocą czujnika momentu i kąta","reference":"KP-PB-40","norm_bases":["KP-PB-40"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt obrotu klucza dynamometrycznego Wzorcowanie – kąt płaski Pomiar bezpośredni za pomocą czujnika momentu i kąta od 0 ° do 270 ° CMC 0,32° Úhel natočení momentového klíče Kalibrace – rovinný úhel Přímé měření pomocí snímače momentu úhlu 0 ° až 270 ° CMC 0,32° KP-PB-40 Kat obrotu klucza dynamometrycznego Wzorcowanie – kat plaski Pomiar bezposredni za pomoca czujnika momentu i kata od 0 ° do 270 ° CMC 0,32° Uhel natoceni momentoveho klice Kalibrace – rovinny uhel Prime mereni pomoci snimace momentu uhlu 0 ° az 270 ° CMC 0,32° KP-PB-40","search_en":"Rotation angle of torque wrench Calibration – plane angle Direct measurement by an angle sensor Mladá Boleslav CMC for the field of measured quantity: Plane angle Direct measurement by an angle sensor KP-PB-40","search_zh":"扭矩扳手转角 校准 – 平面角 用扭矩角度传感器直接测量 姆拉达-博莱斯拉夫 被测量领域的CMC：平面角 用扭矩角度传感器直接测量 KP-PB-40","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – ebener Winkel","parameters_de":[{"name":"","range":"von 0 ° bis 270 °","cmc":"0,32°"}],"regulatory_area_de":"CMC für den Messgrößenbereich: ebener Winkel","search_de":"Drehwinkel des Drehmomentschlüssels Kalibrierung – ebener Winkel Direkte Messung mit einem Drehmoment- und Drehwinkelsensor Mladá Boleslav CMC für den Messgrößenbereich: ebener Winkel Direkte Messung mit einem Drehmoment- und Drehwinkelsensor KP-PB-40","technique_de":"Direkte Messung mit einem Drehmoment- und Drehwinkelsensor","techniques_de":["Direkte Messung mit einem Drehmoment- und Drehwinkelsensor"],"test_object_de":"Drehwinkel des Drehmomentschlüssels"},{"_id":"9d0267c8608804f7cae27434","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 1 mg do 200 mg","cmc":"0,018 mg"},{"name":"","range":"od 200 mg do 1 g","cmc":"0,026 mg"},{"name":"","range":"od 1 g do 2 g","cmc":"0,032 mg"},{"name":"","range":"od 2 g do 10 g","cmc":"0,050 mg"},{"name":"","range":"od 10 g do 20 g","cmc":"0,064 mg"},{"name":"","range":"od 20 g do 50 g","cmc":"0,078 mg"},{"name":"","range":"od 50 g do 100 g","cmc":"0,13 mg"},{"name":"","range":"od 100 g do 5 kg","cmc":"1,3·10⁻⁶"}],"parameters_en":[{"name":"","range":"from 1 mg to 200 mg","cmc":"0,018 mg"},{"name":"","range":"from 200 mg to 1 g","cmc":"0,026 mg"},{"name":"","range":"from 1 g to 2 g","cmc":"0,032 mg"},{"name":"","range":"from 2 g to 10 g","cmc":"0,050 mg"},{"name":"","range":"from 10 g to 20 g","cmc":"0,064 mg"},{"name":"","range":"from 20 g to 50 g","cmc":"0,078 mg"},{"name":"","range":"from 50 g to 100 g","cmc":"0,13 mg"},{"name":"","range":"100 g to 5 kg","cmc":"1,3·10⁻⁶"}],"parameters_zh":[{"name":"","range":"1 mg 至 200 mg","cmc":"0,018 mg"},{"name":"","range":"200 mg 至 1 g","cmc":"0,026 mg"},{"name":"","range":"1 g 至 2 g","cmc":"0,032 mg"},{"name":"","range":"2 g 至 10 g","cmc":"0,050 mg"},{"name":"","range":"10 g 至 20 g","cmc":"0,064 mg"},{"name":"","range":"20 g 至 50 g","cmc":"0,078 mg"},{"name":"","range":"50 g 至 100 g","cmc":"0,13 mg"},{"name":"","range":"100 g 至 5 kg","cmc":"1,3·10⁻⁶"}],"parameters_cs":[{"name":"","range":"1 mg až 200 mg","cmc":"0,018 mg"},{"name":"","range":"200 mg až 1 g","cmc":"0,026 mg"},{"name":"","range":"1 g až 2 g","cmc":"0,032 mg"},{"name":"","range":"2 g až 10 g","cmc":"0,050 mg"},{"name":"","range":"10 g až 20 g","cmc":"0,064 mg"},{"name":"","range":"20 g až 50 g","cmc":"0,078 mg"},{"name":"","range":"50 g až 100 g","cmc":"0,13 mg"},{"name":"","range":"100 g až 5 kg","cmc":"1,3·10⁻⁶"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2","technique_en":"Loading using a class E2 reference weight (acc. to OIML R111-1:2004)","technique_zh":"用E2级标准砝码加载（依据 OIML R111-1:2004）","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy E2","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2"],"techniques_en":["Loading using a class E2 reference weight (acc. to OIML R111-1:2004)"],"techniques_zh":["用E2级标准砝码加载（依据 OIML R111-1:2004）"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy E2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 1 mg do 200 mg CMC 0,018 mg\nod 200 mg do 1 g CMC 0,026 mg\nod 1 g do 2 g CMC 0,032 mg\nod 2 g do 10 g CMC 0,050 mg\nod 10 g do 20 g CMC 0,064 mg\nod 20 g do 50 g CMC 0,078 mg\nod 50 g do 100 g CMC 0,13 mg\nod 100 g do 5 kg CMC 1,3·10⁻⁶\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2","reference":"KP-PB-71","norm_bases":["KP-PB-71"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2 od 1 mg do 200 mg CMC 0,018 mg od 200 mg do 1 g CMC 0,026 mg od 1 g do 2 g CMC 0,032 mg od 2 g do 10 g CMC 0,050 mg od 10 g do 20 g CMC 0,064 mg od 20 g do 50 g CMC 0,078 mg od 50 g do 100 g CMC 0,13 mg od 100 g do 5 kg CMC 1,3·10⁻⁶ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy E2 1 mg až 200 mg CMC 0,018 mg 200 mg až 1 g CMC 0,026 mg 1 g až 2 g CMC 0,032 mg 2 g až 10 g CMC 0,050 mg 10 g až 20 g CMC 0,064 mg 20 g až 50 g CMC 0,078 mg 50 g až 100 g CMC 0,13 mg 100 g až 5 kg CMC 1,3·10⁻⁶ KP-PB-71 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy E2 od 1 mg do 200 mg CMC 0,018 mg od 200 mg do 1 g CMC 0,026 mg od 1 g do 2 g CMC 0,032 mg od 2 g do 10 g CMC 0,050 mg od 10 g do 20 g CMC 0,064 mg od 20 g do 50 g CMC 0,078 mg od 50 g do 100 g CMC 0,13 mg od 100 g do 5 kg CMC 1,3·10⁻⁶ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy E2 1 mg az 200 mg CMC 0,018 mg 200 mg az 1 g CMC 0,026 mg 1 g az 2 g CMC 0,032 mg 2 g az 10 g CMC 0,050 mg 10 g az 20 g CMC 0,064 mg 20 g az 50 g CMC 0,078 mg 50 g az 100 g CMC 0,13 mg 100 g az 5 kg CMC 1,3·10⁻⁶ KP-PB-71","search_en":"Balances with non-automatic function Calibration – mass Loading using a class E2 reference weight (acc. to OIML R111-1:2004) Uherský Brod II CMC for the field of measured quantity: Mass Loading using a class E2 reference weight (acc. to OIML R111-1:2004) KP-PB-71","search_zh":"非自动衡器 校准 – 质量 用E2级标准砝码加载（依据 OIML R111-1:2004） 乌赫尔斯基布罗德 II 被测量领域的CMC：质量 用E2级标准砝码加载（依据 OIML R111-1:2004） KP-PB-71","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Masse","parameters_de":[{"name":"","range":"von 1 mg bis 200 mg","cmc":"0,018 mg"},{"name":"","range":"von 200 mg bis 1 g","cmc":"0,026 mg"},{"name":"","range":"von 1 g bis 2 g","cmc":"0,032 mg"},{"name":"","range":"von 2 g bis 10 g","cmc":"0,050 mg"},{"name":"","range":"von 10 g bis 20 g","cmc":"0,064 mg"},{"name":"","range":"von 20 g bis 50 g","cmc":"0,078 mg"},{"name":"","range":"von 50 g bis 100 g","cmc":"0,13 mg"},{"name":"","range":"von 100 g bis 5 kg","cmc":"1,3·10⁻⁶"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Masse","search_de":"Nichtselbsttätige Waagen Kalibrierung – Masse Belastung mit Referenzgewichtstück (nach OIML R111-1:2004) der Klasse E2 Uherský Brod II CMC für den Messgrößenbereich: Masse Belastung mit Referenzgewichtstück (nach OIML R111-1:2004) der Klasse E2 KP-PB-71","technique_de":"Belastung mit Referenzgewichtstück (nach OIML R111-1:2004) der Klasse E2","techniques_de":["Belastung mit Referenzgewichtstück (nach OIML R111-1:2004) der Klasse E2"],"test_object_de":"Nichtselbsttätige Waagen"},{"_id":"4f01810fe6ae1b955eada4b2","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 5 kg do 55 kg","cmc":"6·10⁻⁶"}],"parameters_en":[{"name":"","range":"5 kg to 55 kg","cmc":"6·10⁻⁶"}],"parameters_zh":[{"name":"","range":"5 kg 至 55 kg","cmc":"6·10⁻⁶"}],"parameters_cs":[{"name":"","range":"5 kg až 55 kg","cmc":"6·10⁻⁶"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1","technique_en":"Loading using a class F1 reference weight (acc. to OIML R111-1:2004)","technique_zh":"用F1级标准砝码加载（依据 OIML R111-1:2004）","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F1","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1"],"techniques_en":["Loading using a class F1 reference weight (acc. to OIML R111-1:2004)"],"techniques_zh":["用F1级标准砝码加载（依据 OIML R111-1:2004）"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F1"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nod 5 kg do 55 kg CMC 6·10⁻⁶\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1","reference":"KP-PB-71","norm_bases":["KP-PB-71"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1 od 5 kg do 55 kg CMC 6·10⁻⁶ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F1 5 kg až 55 kg CMC 6·10⁻⁶ KP-PB-71 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy F1 od 5 kg do 55 kg CMC 6·10⁻⁶ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy F1 5 kg az 55 kg CMC 6·10⁻⁶ KP-PB-71","search_en":"Balances with non-automatic function Calibration – mass Loading using a class F1 reference weight (acc. to OIML R111-1:2004) Uherský Brod II CMC for the field of measured quantity: Mass Loading using a class F1 reference weight (acc. to OIML R111-1:2004) KP-PB-71","search_zh":"非自动衡器 校准 – 质量 用F1级标准砝码加载（依据 OIML R111-1:2004） 乌赫尔斯基布罗德 II 被测量领域的CMC：质量 用F1级标准砝码加载（依据 OIML R111-1:2004） KP-PB-71","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Masse","parameters_de":[{"name":"","range":"von 5 kg bis 55 kg","cmc":"6·10⁻⁶"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Masse","search_de":"Nichtselbsttätige Waagen Kalibrierung – Masse Belastung mit Referenzgewichtstück (nach OIML R111-1:2004) der Klasse F1 Uherský Brod II CMC für den Messgrößenbereich: Masse Belastung mit Referenzgewichtstück (nach OIML R111-1:2004) der Klasse F1 KP-PB-71","technique_de":"Belastung mit Referenzgewichtstück (nach OIML R111-1:2004) der Klasse F1","techniques_de":["Belastung mit Referenzgewichtstück (nach OIML R111-1:2004) der Klasse F1"],"test_object_de":"Nichtselbsttätige Waagen"},{"_id":"e14958f9525853c2ee70530b","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 55 kg do 150 kg","cmc":"2,2·10⁻⁵"}],"parameters_en":[{"name":"","range":"55 kg to 150 kg","cmc":"2,2·10⁻⁵"}],"parameters_zh":[{"name":"","range":"55 kg 至 150 kg","cmc":"2,2·10⁻⁵"}],"parameters_cs":[{"name":"","range":"55 kg až 150 kg","cmc":"2,2·10⁻⁵"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2","technique_en":"Loading using a class F2 reference weight (acc. to OIML R111-1:2004)","technique_zh":"用F2级标准砝码加载（依据 OIML R111-1:2004）","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F2","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2"],"techniques_en":["Loading using a class F2 reference weight (acc. to OIML R111-1:2004)"],"techniques_zh":["用F2级标准砝码加载（依据 OIML R111-1:2004）"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nod 55 kg do 150 kg CMC 2,2·10⁻⁵\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2","reference":"KP-PB-71","norm_bases":["KP-PB-71"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2 od 55 kg do 150 kg CMC 2,2·10⁻⁵ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F2 55 kg až 150 kg CMC 2,2·10⁻⁵ KP-PB-71 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy F2 od 55 kg do 150 kg CMC 2,2·10⁻⁵ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy F2 55 kg az 150 kg CMC 2,2·10⁻⁵ KP-PB-71","search_en":"Balances with non-automatic function Calibration – mass Loading using a class F2 reference weight (acc. to OIML R111-1:2004) Uherský Brod II CMC for the field of measured quantity: Mass Loading using a class F2 reference weight (acc. to OIML R111-1:2004) KP-PB-71","search_zh":"非自动衡器 校准 – 质量 用F2级标准砝码加载（依据 OIML R111-1:2004） 乌赫尔斯基布罗德 II 被测量领域的CMC：质量 用F2级标准砝码加载（依据 OIML R111-1:2004） KP-PB-71","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Masse","parameters_de":[{"name":"","range":"von 55 kg bis 150 kg","cmc":"2,2·10⁻⁵"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Masse","search_de":"Nichtselbsttätige Waagen Kalibrierung – Masse Belastung mit einem Normalgewicht (nach OIML R111-1:2004) der Klasse F2 Uherský Brod II CMC für den Messgrößenbereich: Masse Belastung mit einem Normalgewicht (nach OIML R111-1:2004) der Klasse F2 KP-PB-71","technique_de":"Belastung mit einem Normalgewicht (nach OIML R111-1:2004) der Klasse F2","techniques_de":["Belastung mit einem Normalgewicht (nach OIML R111-1:2004) der Klasse F2"],"test_object_de":"Nichtselbsttätige Waagen"},{"_id":"0be9054618611a4931c52270","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 150 kg do 1 t","cmc":"7,3·10⁻⁵"}],"parameters_en":[{"name":"","range":"150 kg to 1 t","cmc":"7,3·10⁻⁵"}],"parameters_zh":[{"name":"","range":"150 kg 至 1 t","cmc":"7,3·10⁻⁵"}],"parameters_cs":[{"name":"","range":"150 kg až 1 t","cmc":"7,3·10⁻⁵"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1","technique_en":"Loading using a class M1 reference weight (acc. to OIML R111-1:2004)","technique_zh":"用M1级标准砝码加载（依据 OIML R111-1:2004）","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy M1","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1"],"techniques_en":["Loading using a class M1 reference weight (acc. to OIML R111-1:2004)"],"techniques_zh":["用M1级标准砝码加载（依据 OIML R111-1:2004）"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy M1"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nod 150 kg do 1 t CMC 7,3·10⁻⁵\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1","reference":"KP-PB-71","norm_bases":["KP-PB-71"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1 od 150 kg do 1 t CMC 7,3·10⁻⁵ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy M1 150 kg až 1 t CMC 7,3·10⁻⁵ KP-PB-71 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy M1 od 150 kg do 1 t CMC 7,3·10⁻⁵ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy M1 150 kg az 1 t CMC 7,3·10⁻⁵ KP-PB-71","search_en":"Balances with non-automatic function Calibration – mass Loading using a class M1 reference weight (acc. to OIML R111-1:2004) Uherský Brod II CMC for the field of measured quantity: Mass Loading using a class M1 reference weight (acc. to OIML R111-1:2004) KP-PB-71","search_zh":"非自动衡器 校准 – 质量 用M1级标准砝码加载（依据 OIML R111-1:2004） 乌赫尔斯基布罗德 II 被测量领域的CMC：质量 用M1级标准砝码加载（依据 OIML R111-1:2004） KP-PB-71","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Masse","parameters_de":[{"name":"","range":"von 150 kg bis 1 t","cmc":"7,3·10⁻⁵"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Masse","search_de":"Nichtselbsttätige Waagen Kalibrierung – Masse Belastung mit einem Normalgewicht (nach OIML R111-1:2004) der Klasse M1 Uherský Brod II CMC für den Messgrößenbereich: Masse Belastung mit einem Normalgewicht (nach OIML R111-1:2004) der Klasse M1 KP-PB-71","technique_de":"Belastung mit einem Normalgewicht (nach OIML R111-1:2004) der Klasse M1","techniques_de":["Belastung mit einem Normalgewicht (nach OIML R111-1:2004) der Klasse M1"],"test_object_de":"Nichtselbsttätige Waagen"},{"_id":"cbf1e9186988596274049d93","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Masa umowna odważników i ciał","test_object_en":"Conventional mass of weights and bodies","test_object_zh":"砝码和物体的约定质量","test_object_cs":"Konvenční hmotnost závaží a těles","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 1 mg do 5 mg","cmc":"0,0020 mg"},{"name":"","range":"10 mg","cmc":"0,0022 mg"},{"name":"","range":"20 mg","cmc":"0,0023 mg"},{"name":"","range":"50 mg","cmc":"0,0029 mg"},{"name":"","range":"100 mg","cmc":"0,0035 mg"},{"name":"","range":"200 mg","cmc":"0,0043 mg"},{"name":"","range":"500 mg","cmc":"0,0053 mg"},{"name":"","range":"1 g","cmc":"0,0064 mg"},{"name":"","range":"2 g","cmc":"0,0083 mg"},{"name":"","range":"5 g","cmc":"0,011 mg"},{"name":"","range":"10 g","cmc":"0,013 mg"},{"name":"","range":"20 g","cmc":"0,017 mg"},{"name":"","range":"50 g","cmc":"0,024 mg"},{"name":"","range":"100 g","cmc":"0,032 mg"},{"name":"","range":"200 g","cmc":"0,062 mg"},{"name":"","range":"500 g","cmc":"0,16 mg"},{"name":"","range":"1 kg","cmc":"0,32 mg"},{"name":"","range":"2 kg","cmc":"0,62 mg"},{"name":"","range":"5 kg","cmc":"1,6 mg"},{"name":"","range":"10 kg","cmc":"14 mg"},{"name":"","range":"20 kg","cmc":"24 mg"}],"parameters_en":[{"name":"","range":"from 1 mg to 5 mg","cmc":"0,0020 mg"},{"name":"","range":"10 mg","cmc":"0,0022 mg"},{"name":"","range":"20 mg","cmc":"0,0023 mg"},{"name":"","range":"50 mg","cmc":"0,0029 mg"},{"name":"","range":"100 mg","cmc":"0,0035 mg"},{"name":"","range":"200 mg","cmc":"0,0043 mg"},{"name":"","range":"500 mg","cmc":"0,0053 mg"},{"name":"","range":"1 g","cmc":"0,0064 mg"},{"name":"","range":"2 g","cmc":"0,0083 mg"},{"name":"","range":"5 g","cmc":"0,011 mg"},{"name":"","range":"10 g","cmc":"0,013 mg"},{"name":"","range":"20 g","cmc":"0,017 mg"},{"name":"","range":"50 g","cmc":"0,024 mg"},{"name":"","range":"100 g","cmc":"0,032 mg"},{"name":"","range":"200 g","cmc":"0,062 mg"},{"name":"","range":"500 g","cmc":"0,16 mg"},{"name":"","range":"1 kg","cmc":"0,32 mg"},{"name":"","range":"2 kg","cmc":"0,62 mg"},{"name":"","range":"5 kg","cmc":"1,6 mg"},{"name":"","range":"10 kg","cmc":"14 mg"},{"name":"","range":"20 kg","cmc":"24 mg"}],"parameters_zh":[{"name":"","range":"1 mg 至 5 mg","cmc":"0,0020 mg"},{"name":"","range":"10 mg","cmc":"0,0022 mg"},{"name":"","range":"20 mg","cmc":"0,0023 mg"},{"name":"","range":"50 mg","cmc":"0,0029 mg"},{"name":"","range":"100 mg","cmc":"0,0035 mg"},{"name":"","range":"200 mg","cmc":"0,0043 mg"},{"name":"","range":"500 mg","cmc":"0,0053 mg"},{"name":"","range":"1 g","cmc":"0,0064 mg"},{"name":"","range":"2 g","cmc":"0,0083 mg"},{"name":"","range":"5 g","cmc":"0,011 mg"},{"name":"","range":"10 g","cmc":"0,013 mg"},{"name":"","range":"20 g","cmc":"0,017 mg"},{"name":"","range":"50 g","cmc":"0,024 mg"},{"name":"","range":"100 g","cmc":"0,032 mg"},{"name":"","range":"200 g","cmc":"0,062 mg"},{"name":"","range":"500 g","cmc":"0,16 mg"},{"name":"","range":"1 kg","cmc":"0,32 mg"},{"name":"","range":"2 kg","cmc":"0,62 mg"},{"name":"","range":"5 kg","cmc":"1,6 mg"},{"name":"","range":"10 kg","cmc":"14 mg"},{"name":"","range":"20 kg","cmc":"24 mg"}],"parameters_cs":[{"name":"","range":"1 mg až 5 mg","cmc":"0,0020 mg"},{"name":"","range":"10 mg","cmc":"0,0022 mg"},{"name":"","range":"20 mg","cmc":"0,0023 mg"},{"name":"","range":"50 mg","cmc":"0,0029 mg"},{"name":"","range":"100 mg","cmc":"0,0035 mg"},{"name":"","range":"200 mg","cmc":"0,0043 mg"},{"name":"","range":"500 mg","cmc":"0,0053 mg"},{"name":"","range":"1 g","cmc":"0,0064 mg"},{"name":"","range":"2 g","cmc":"0,0083 mg"},{"name":"","range":"5 g","cmc":"0,011 mg"},{"name":"","range":"10 g","cmc":"0,013 mg"},{"name":"","range":"20 g","cmc":"0,017 mg"},{"name":"","range":"50 g","cmc":"0,024 mg"},{"name":"","range":"100 g","cmc":"0,032 mg"},{"name":"","range":"200 g","cmc":"0,062 mg"},{"name":"","range":"500 g","cmc":"0,16 mg"},{"name":"","range":"1 kg","cmc":"0,32 mg"},{"name":"","range":"2 kg","cmc":"0,62 mg"},{"name":"","range":"5 kg","cmc":"1,6 mg"},{"name":"","range":"10 kg","cmc":"14 mg"},{"name":"","range":"20 kg","cmc":"24 mg"}],"technique":"Porównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach","technique_en":"Comparison with a reference weight (acc. to OIML R111-1:2004) on reference scales and comparators","technique_zh":"在标准天平和质量比较仪上与标准砝码比较（依据 OIML R111-1:2004）","technique_cs":"Porovnání s etalonovým závažím (dle OIML R111-1:2004) na etalonových vahách a komparátorech","techniques":["Porównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach"],"techniques_en":["Comparison with a reference weight (acc. to OIML R111-1:2004) on reference scales and comparators"],"techniques_zh":["在标准天平和质量比较仪上与标准砝码比较（依据 OIML R111-1:2004）"],"techniques_cs":["Porovnání s etalonovým závažím (dle OIML R111-1:2004) na etalonových vahách a komparátorech"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 1 mg do 5 mg CMC 0,0020 mg\n10 mg CMC 0,0022 mg\n20 mg CMC 0,0023 mg\n50 mg CMC 0,0029 mg\n100 mg CMC 0,0035 mg\n200 mg CMC 0,0043 mg\n500 mg CMC 0,0053 mg\n1 g CMC 0,0064 mg\n2 g CMC 0,0083 mg\n5 g CMC 0,011 mg\n10 g CMC 0,013 mg\n20 g CMC 0,017 mg\n50 g CMC 0,024 mg\n100 g CMC 0,032 mg\n200 g CMC 0,062 mg\n500 g CMC 0,16 mg\n1 kg CMC 0,32 mg\n2 kg CMC 0,62 mg\n5 kg CMC 1,6 mg\n10 kg CMC 14 mg\n20 kg CMC 24 mg\nPorównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach","reference":"KP-PB-75","norm_bases":["KP-PB-75"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":"Odważnikom o indywidualnej wartości nominalnej leżącej między podanymi wartościami przypisuje się niepewność bezpośrednio wyższą.","note_en":"Weights with an individual nominal value lying between the defined values are assigned the next higher uncertainty.","note_zh":"对于标称值介于所列数值之间的砝码，取紧邻较高的不确定度。","note_cs":"U závaží s individuální jmenovitou hodnotou ležící mezi definovanými hodnotami je přiřazena nejistota bezprostředně vyšší.","search_text":"Masa umowna odważników i ciał Wzorcowanie – masa Porównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach od 1 mg do 5 mg CMC 0,0020 mg 10 mg CMC 0,0022 mg 20 mg CMC 0,0023 mg 50 mg CMC 0,0029 mg 100 mg CMC 0,0035 mg 200 mg CMC 0,0043 mg 500 mg CMC 0,0053 mg 1 g CMC 0,0064 mg 2 g CMC 0,0083 mg 5 g CMC 0,011 mg 10 g CMC 0,013 mg 20 g CMC 0,017 mg 50 g CMC 0,024 mg 100 g CMC 0,032 mg 200 g CMC 0,062 mg 500 g CMC 0,16 mg 1 kg CMC 0,32 mg 2 kg CMC 0,62 mg 5 kg CMC 1,6 mg 10 kg CMC 14 mg 20 kg CMC 24 mg Konvenční hmotnost závaží a těles Kalibrace – hmotnost Porovnání s etalonovým závažím (dle OIML R111-1:2004) na etalonových vahách a komparátorech 1 mg až 5 mg CMC 0,0020 mg 10 mg CMC 0,0022 mg 20 mg CMC 0,0023 mg 50 mg CMC 0,0029 mg 100 mg CMC 0,0035 mg 200 mg CMC 0,0043 mg 500 mg CMC 0,0053 mg 1 g CMC 0,0064 mg 2 g CMC 0,0083 mg 5 g CMC 0,011 mg 10 g CMC 0,013 mg 20 g CMC 0,017 mg 50 g CMC 0,024 mg 100 g CMC 0,032 mg 200 g CMC 0,062 mg 500 g CMC 0,16 mg 1 kg CMC 0,32 mg 2 kg CMC 0,62 mg 5 kg CMC 1,6 mg 10 kg CMC 14 mg 20 kg CMC 24 mg KP-PB-75 Masa umowna odwaznikow i cial Wzorcowanie – masa Porownanie z odwaznikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach od 1 mg do 5 mg CMC 0,0020 mg 10 mg CMC 0,0022 mg 20 mg CMC 0,0023 mg 50 mg CMC 0,0029 mg 100 mg CMC 0,0035 mg 200 mg CMC 0,0043 mg 500 mg CMC 0,0053 mg 1 g CMC 0,0064 mg 2 g CMC 0,0083 mg 5 g CMC 0,011 mg 10 g CMC 0,013 mg 20 g CMC 0,017 mg 50 g CMC 0,024 mg 100 g CMC 0,032 mg 200 g CMC 0,062 mg 500 g CMC 0,16 mg 1 kg CMC 0,32 mg 2 kg CMC 0,62 mg 5 kg CMC 1,6 mg 10 kg CMC 14 mg 20 kg CMC 24 mg Konvencni hmotnost zavazi a teles Kalibrace – hmotnost Porovnani s etalonovym zavazim (dle OIML R111-1:2004) na etalonovych vahach a komparatorech 1 mg az 5 mg CMC 0,0020 mg 10 mg CMC 0,0022 mg 20 mg CMC 0,0023 mg 50 mg CMC 0,0029 mg 100 mg CMC 0,0035 mg 200 mg CMC 0,0043 mg 500 mg CMC 0,0053 mg 1 g CMC 0,0064 mg 2 g CMC 0,0083 mg 5 g CMC 0,011 mg 10 g CMC 0,013 mg 20 g CMC 0,017 mg 50 g CMC 0,024 mg 100 g CMC 0,032 mg 200 g CMC 0,062 mg 500 g CMC 0,16 mg 1 kg CMC 0,32 mg 2 kg CMC 0,62 mg 5 kg CMC 1,6 mg 10 kg CMC 14 mg 20 kg CMC 24 mg KP-PB-75","search_en":"Conventional mass of weights and bodies Calibration – mass Comparison with a reference weight (acc. to OIML R111-1:2004) on reference scales and comparators Uherský Brod II CMC for the field of measured quantity: Mass Comparison with a reference weight (acc. to OIML R111-1:2004) on reference scales and comparators KP-PB-75","search_zh":"砝码和物体的约定质量 校准 – 质量 在标准天平和质量比较仪上与标准砝码比较（依据 OIML R111-1:2004） 乌赫尔斯基布罗德 II 被测量领域的CMC：质量 在标准天平和质量比较仪上与标准砝码比较（依据 OIML R111-1:2004） KP-PB-75","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Masse","parameters_de":[{"name":"","range":"von 1 mg bis 5 mg","cmc":"0,0020 mg"},{"name":"","range":"10 mg","cmc":"0,0022 mg"},{"name":"","range":"20 mg","cmc":"0,0023 mg"},{"name":"","range":"50 mg","cmc":"0,0029 mg"},{"name":"","range":"100 mg","cmc":"0,0035 mg"},{"name":"","range":"200 mg","cmc":"0,0043 mg"},{"name":"","range":"500 mg","cmc":"0,0053 mg"},{"name":"","range":"1 g","cmc":"0,0064 mg"},{"name":"","range":"2 g","cmc":"0,0083 mg"},{"name":"","range":"5 g","cmc":"0,011 mg"},{"name":"","range":"10 g","cmc":"0,013 mg"},{"name":"","range":"20 g","cmc":"0,017 mg"},{"name":"","range":"50 g","cmc":"0,024 mg"},{"name":"","range":"100 g","cmc":"0,032 mg"},{"name":"","range":"200 g","cmc":"0,062 mg"},{"name":"","range":"500 g","cmc":"0,16 mg"},{"name":"","range":"1 kg","cmc":"0,32 mg"},{"name":"","range":"2 kg","cmc":"0,62 mg"},{"name":"","range":"5 kg","cmc":"1,6 mg"},{"name":"","range":"10 kg","cmc":"14 mg"},{"name":"","range":"20 kg","cmc":"24 mg"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Masse","search_de":"Konventioneller Wägewert von Gewichtsstücken und Körpern Kalibrierung – Masse Vergleich mit Normalgewichtstück (nach OIML R111-1:2004) auf Normalwaagen und Komparatoren Uherský Brod II CMC für den Messgrößenbereich: Masse Vergleich mit Normalgewichtstück (nach OIML R111-1:2004) auf Normalwaagen und Komparatoren KP-PB-75","technique_de":"Vergleich mit Normalgewichtstück (nach OIML R111-1:2004) auf Normalwaagen und Komparatoren","techniques_de":["Vergleich mit Normalgewichtstück (nach OIML R111-1:2004) auf Normalwaagen und Komparatoren"],"test_object_de":"Konventioneller Wägewert von Gewichtsstücken und Körpern"},{"_id":"0721d5c4cb6eef56ba46888c","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Moment siły / klucze dynamometryczne, wkrętaki dynamometryczne","test_object_en":"Torque / torque wrenches, torque screwdrivers","test_object_zh":"扭矩 / 扭矩扳手、扭矩螺丝刀","test_object_cs":"Moment síly/ momentové klíče, momentové šroubováky","methodology":"Wzorcowanie – siła","methodology_en":"Calibration – force","methodology_zh":"校准 – 力","methodology_cs":"Kalibrace – síla","parameters":[{"name":"","range":"od 0,2 N·m do 1000 N·m","cmc":"0,4 %"}],"parameters_en":[{"name":"","range":"from 0,2 N·m to 1000 N·m","cmc":"0,4 %"}],"parameters_zh":[{"name":"","range":"0,2 N·m 至 1000 N·m","cmc":"0,4 %"}],"parameters_cs":[{"name":"","range":"0,2 N·m až 1000 N·m","cmc":"0,4 %"}],"technique":"Pomiar bezpośredni za pomocą czujnika momentu siły","technique_en":"Direct measurement by a torque sensor","technique_zh":"用扭矩传感器直接测量","technique_cs":"Přímé měření pomocí snímače momentu síly","techniques":["Pomiar bezpośredni za pomocą czujnika momentu siły"],"techniques_en":["Direct measurement by a torque sensor"],"techniques_zh":["用扭矩传感器直接测量"],"techniques_cs":["Přímé měření pomocí snímače momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła\nod 0,2 N·m do 1000 N·m CMC 0,4 %\nPomiar bezpośredni za pomocą czujnika momentu siły","reference":"KP-PB-40","norm_bases":["KP-PB-40"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła","regulatory_area_en":"CMC for the field of measured quantity: Force","regulatory_area_zh":"被测量领域的CMC：力","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moment siły / klucze dynamometryczne, wkrętaki dynamometryczne Wzorcowanie – siła Pomiar bezpośredni za pomocą czujnika momentu siły od 0,2 N·m do 1000 N·m CMC 0,4 % Moment síly/ momentové klíče, momentové šroubováky Kalibrace – síla Přímé měření pomocí snímače momentu síly 0,2 N·m až 1000 N·m CMC 0,4 % KP-PB-40 Moment sily / klucze dynamometryczne, wkretaki dynamometryczne Wzorcowanie – sila Pomiar bezposredni za pomoca czujnika momentu sily od 0,2 N·m do 1000 N·m CMC 0,4 % Moment sily/ momentove klice, momentove sroubovaky Kalibrace – sila Prime mereni pomoci snimace momentu sily 0,2 N·m az 1000 N·m CMC 0,4 % KP-PB-40","search_en":"Torque / torque wrenches, torque screwdrivers Calibration – force Direct measurement by a torque sensor Uherský Brod CMC for the field of measured quantity: Force Direct measurement by a torque sensor KP-PB-40","search_zh":"扭矩 / 扭矩扳手、扭矩螺丝刀 校准 – 力 用扭矩传感器直接测量 乌赫尔斯基布罗德 被测量领域的CMC：力 用扭矩传感器直接测量 KP-PB-40","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Kraft","parameters_de":[{"name":"","range":"von 0,2 N·m bis 1000 N·m","cmc":"0,4 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Kraft","search_de":"Drehmoment / Drehmomentschlüssel, Drehmomentschraubendreher Kalibrierung – Kraft Direkte Messung mit einem Drehmomentsensor Uherský Brod CMC für den Messgrößenbereich: Kraft Direkte Messung mit einem Drehmomentsensor KP-PB-40","technique_de":"Direkte Messung mit einem Drehmomentsensor","techniques_de":["Direkte Messung mit einem Drehmomentsensor"],"test_object_de":"Drehmoment / Drehmomentschlüssel, Drehmomentschraubendreher"},{"_id":"918b723feaaeb935275f816f","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Moment siły / klucze dynamometryczne, wkrętaki dynamometryczne","test_object_en":"Torque / torque wrenches, torque screwdrivers","test_object_zh":"扭矩 / 扭矩扳手、扭矩螺丝刀","test_object_cs":"Moment síly/ momentové klíče, momentové šroubováky","methodology":"Wzorcowanie – siła","methodology_en":"Calibration – force","methodology_zh":"校准 – 力","methodology_cs":"Kalibrace – síla","parameters":[{"name":"","range":"od 0,2 N·m do 1000 N·m","cmc":"0,4 %"}],"parameters_en":[{"name":"","range":"from 0,2 N·m to 1000 N·m","cmc":"0,4 %"}],"parameters_zh":[{"name":"","range":"0,2 N·m 至 1000 N·m","cmc":"0,4 %"}],"parameters_cs":[{"name":"","range":"0,2 N·m až 1000 N·m","cmc":"0,4 %"}],"technique":"Pomiar bezpośredni za pomocą czujnika momentu siły","technique_en":"Direct measurement by a torque sensor","technique_zh":"用扭矩传感器直接测量","technique_cs":"Přímé měření pomocí snímače momentu síly","techniques":["Pomiar bezpośredni za pomocą czujnika momentu siły"],"techniques_en":["Direct measurement by a torque sensor"],"techniques_zh":["用扭矩传感器直接测量"],"techniques_cs":["Přímé měření pomocí snímače momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła\nod 0,2 N·m do 1000 N·m CMC 0,4 %\nPomiar bezpośredni za pomocą czujnika momentu siły","reference":"KP-PB-40","norm_bases":["KP-PB-40"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła","regulatory_area_en":"CMC for the field of measured quantity: Force","regulatory_area_zh":"被测量领域的CMC：力","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moment siły / klucze dynamometryczne, wkrętaki dynamometryczne Wzorcowanie – siła Pomiar bezpośredni za pomocą czujnika momentu siły od 0,2 N·m do 1000 N·m CMC 0,4 % Moment síly/ momentové klíče, momentové šroubováky Kalibrace – síla Přímé měření pomocí snímače momentu síly 0,2 N·m až 1000 N·m CMC 0,4 % KP-PB-40 Moment sily / klucze dynamometryczne, wkretaki dynamometryczne Wzorcowanie – sila Pomiar bezposredni za pomoca czujnika momentu sily od 0,2 N·m do 1000 N·m CMC 0,4 % Moment sily/ momentove klice, momentove sroubovaky Kalibrace – sila Prime mereni pomoci snimace momentu sily 0,2 N·m az 1000 N·m CMC 0,4 % KP-PB-40","search_en":"Torque / torque wrenches, torque screwdrivers Calibration – force Direct measurement by a torque sensor Mladá Boleslav CMC for the field of measured quantity: Force Direct measurement by a torque sensor KP-PB-40","search_zh":"扭矩 / 扭矩扳手、扭矩螺丝刀 校准 – 力 用扭矩传感器直接测量 姆拉达-博莱斯拉夫 被测量领域的CMC：力 用扭矩传感器直接测量 KP-PB-40","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Kraft","parameters_de":[{"name":"","range":"von 0,2 N·m bis 1000 N·m","cmc":"0,4 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Kraft","search_de":"Drehmoment / Drehmomentschlüssel, Drehmomentschraubendreher Kalibrierung – Kraft Direkte Messung mit einem Drehmomentsensor Mladá Boleslav CMC für den Messgrößenbereich: Kraft Direkte Messung mit einem Drehmomentsensor KP-PB-40","technique_de":"Direkte Messung mit einem Drehmomentsensor","techniques_de":["Direkte Messung mit einem Drehmomentsensor"],"test_object_de":"Drehmoment / Drehmomentschlüssel, Drehmomentschraubendreher"},{"_id":"d420ad2e23f1f4359caf0f1d","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Siła / siłomierze użytkowe","test_object_en":"Force / Working force-proving instruments","test_object_zh":"力 / 工作测力计","test_object_cs":"Síla / Pracovní siloměry","methodology":"Wzorcowanie – siła","methodology_en":"Calibration – force","methodology_zh":"校准 – 力","methodology_cs":"Kalibrace – síla","parameters":[{"name":"Rozciąganie, ściskanie","range":"od 0,1 N do 200 N","cmc":"0,05 %"}],"parameters_en":[{"name":"Tension, pressure","range":"0,1 N to 200 N","cmc":"0,05 %"}],"parameters_zh":[{"name":"拉力、压力","range":"0,1 N 至 200 N","cmc":"0,05 %"}],"parameters_cs":[{"name":"Tah, tlak","range":"0,1 N až 200 N","cmc":"0,05 %"}],"technique":"Obciążanie przez zawieszanie ciężarków","technique_en":"Suspension by means of load bodies","technique_zh":"悬挂加载砝码","technique_cs":"Zavěšování zatěžovacími tělesy","techniques":["Obciążanie przez zawieszanie ciężarków"],"techniques_en":["Suspension by means of load bodies"],"techniques_zh":["悬挂加载砝码"],"techniques_cs":["Zavěšování zatěžovacími tělesy"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła\nRozciąganie, ściskanie od 0,1 N do 200 N CMC 0,05 %\nObciążanie przez zawieszanie ciężarków","reference":"KP-PB-41","norm_bases":["KP-PB-41"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła","regulatory_area_en":"CMC for the field of measured quantity: Force","regulatory_area_zh":"被测量领域的CMC：力","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Siła / siłomierze użytkowe Wzorcowanie – siła Obciążanie przez zawieszanie ciężarków Rozciąganie, ściskanie od 0,1 N do 200 N CMC 0,05 % Síla / Pracovní siloměry Kalibrace – síla Zavěšování zatěžovacími tělesy Tah, tlak 0,1 N až 200 N CMC 0,05 % KP-PB-41 Sila / silomierze uzytkowe Wzorcowanie – sila Obciazanie przez zawieszanie ciezarkow Rozciaganie, sciskanie od 0,1 N do 200 N CMC 0,05 % Sila / Pracovni silomery Kalibrace – sila Zavesovani zatezovacimi telesy Tah, tlak 0,1 N az 200 N CMC 0,05 % KP-PB-41","search_en":"Force / Working force-proving instruments Calibration – force Suspension by means of load bodies Uherský Brod II CMC for the field of measured quantity: Force Suspension by means of load bodies Tension, pressure KP-PB-41","search_zh":"力 / 工作测力计 校准 – 力 悬挂加载砝码 乌赫尔斯基布罗德 II 被测量领域的CMC：力 悬挂加载砝码 拉力、压力 KP-PB-41","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Kraft","parameters_de":[{"name":"Zug, Druck","range":"von 0,1 N bis 200 N","cmc":"0,05 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Kraft","search_de":"Kraft / Gebrauchskraftmessgeräte Kalibrierung – Kraft Belastung durch Anhängen von Gewichten Uherský Brod II CMC für den Messgrößenbereich: Kraft Belastung durch Anhängen von Gewichten Zug, Druck KP-PB-41","technique_de":"Belastung durch Anhängen von Gewichten","techniques_de":["Belastung durch Anhängen von Gewichten"],"test_object_de":"Kraft / Gebrauchskraftmessgeräte"},{"_id":"b65b1559cba30522244e6a0a","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Siła / siłomierze użytkowe","test_object_en":"Force / Working force-proving instruments","test_object_zh":"力 / 工作测力计","test_object_cs":"Síla / Pracovní siloměry","methodology":"Wzorcowanie – siła","methodology_en":"Calibration – force","methodology_zh":"校准 – 力","methodology_cs":"Kalibrace – síla","parameters":[{"name":"Rozciąganie, ściskanie","range":"od 10 N do 1000 N","cmc":"0,07 %"},{"name":"Rozciąganie, ściskanie","range":"od 1000 N do 2500 N","cmc":"0,13 % FS"}],"parameters_en":[{"name":"Tension, pressure","range":"10 N to 1000 N","cmc":"0,07 %"},{"name":"Tension, pressure","range":"1000 N to 2500 N","cmc":"0,13 % FS"}],"parameters_zh":[{"name":"拉力、压力","range":"10 N 至 1000 N","cmc":"0,07 %"},{"name":"拉力、压力","range":"1000 N 至 2500 N","cmc":"0,13 % FS"}],"parameters_cs":[{"name":"Tah, tlak","range":"10 N až 1000 N","cmc":"0,07 %"},{"name":"Tah, tlak","range":"1000 N až 2500 N","cmc":"0,13 % FS"}],"technique":"Pomiar bezpośredni za pomocą czujnika siły","technique_en":"Direct measurement by a force sensor","technique_zh":"用力传感器直接测量","technique_cs":"Přímé měření pomocí snímače síly","techniques":["Pomiar bezpośredni za pomocą czujnika siły"],"techniques_en":["Direct measurement by a force sensor"],"techniques_zh":["用力传感器直接测量"],"techniques_cs":["Přímé měření pomocí snímače síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła\nZakres:\nRozciąganie, ściskanie od 10 N do 1000 N CMC 0,07 %\nRozciąganie, ściskanie od 1000 N do 2500 N CMC 0,13 % FS\nPomiar bezpośredni za pomocą czujnika siły","reference":"KP-PB-41","norm_bases":["KP-PB-41"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła","regulatory_area_en":"CMC for the field of measured quantity: Force","regulatory_area_zh":"被测量领域的CMC：力","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Siła / siłomierze użytkowe Wzorcowanie – siła Pomiar bezpośredni za pomocą czujnika siły Rozciąganie, ściskanie od 10 N do 1000 N CMC 0,07 % Rozciąganie, ściskanie od 1000 N do 2500 N CMC 0,13 % FS Síla / Pracovní siloměry Kalibrace – síla Přímé měření pomocí snímače síly Tah, tlak 10 N až 1000 N CMC 0,07 % Tah, tlak 1000 N až 2500 N CMC 0,13 % FS KP-PB-41 Sila / silomierze uzytkowe Wzorcowanie – sila Pomiar bezposredni za pomoca czujnika sily Rozciaganie, sciskanie od 10 N do 1000 N CMC 0,07 % Rozciaganie, sciskanie od 1000 N do 2500 N CMC 0,13 % FS Sila / Pracovni silomery Kalibrace – sila Prime mereni pomoci snimace sily Tah, tlak 10 N az 1000 N CMC 0,07 % Tah, tlak 1000 N az 2500 N CMC 0,13 % FS KP-PB-41","search_en":"Force / Working force-proving instruments Calibration – force Direct measurement by a force sensor Uherský Brod II CMC for the field of measured quantity: Force Direct measurement by a force sensor Tension, pressure Tension, pressure KP-PB-41","search_zh":"力 / 工作测力计 校准 – 力 用力传感器直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：力 用力传感器直接测量 拉力、压力 拉力、压力 KP-PB-41","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Kraft","parameters_de":[{"name":"Zug, Druck","range":"von 10 N bis 1000 N","cmc":"0,07 %"},{"name":"Zug, Druck","range":"von 1000 N bis 2500 N","cmc":"0,13 % FS"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Kraft","search_de":"Kraft / Gebrauchskraftmessgeräte Kalibrierung – Kraft Direkte Messung mit einem Kraftsensor Uherský Brod II CMC für den Messgrößenbereich: Kraft Direkte Messung mit einem Kraftsensor Zug, Druck Zug, Druck KP-PB-41","technique_de":"Direkte Messung mit einem Kraftsensor","techniques_de":["Direkte Messung mit einem Kraftsensor"],"test_object_de":"Kraft / Gebrauchskraftmessgeräte"},{"_id":"e45ff0aa9bfc86101a10af46","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i elektromechaniczne","test_object_en":"Mechanical pressure gauges and electromechanical manometers","test_object_zh":"弹性式和机电式压力表","test_object_cs":"Deformační a elektromechanické tlakoměry","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"nadciśnienie, gaz","range":"od -100 kPa do -2 kPa","cmc":"0,025 % + 10 Pa"},{"name":"nadciśnienie, gaz","range":"od -2 kPa do 2 kPa","cmc":"0,1 % + 1 digit"},{"name":"nadciśnienie, gaz","range":"od 2 kPa do 10 kPa","cmc":"0,025 % + 1 Pa"},{"name":"nadciśnienie, gaz","range":"od 10 kPa do 100 kPa","cmc":"0,025 % + 10 Pa"},{"name":"nadciśnienie, gaz","range":"od 0,1 MPa do 2 MPa","cmc":"0,025 % + 0,2 kPa"},{"name":"nadciśnienie, gaz","range":"od 2 MPa do 6 MPa","cmc":"0,025 % + 0,6 kPa"},{"name":"nadciśnienie, gaz","range":"od 6 MPa do 7 MPa","cmc":"1,4 kPa"},{"name":"nadciśnienie, ciecz","range":"od 0 MPa do 6 MPa","cmc":"0,025 % +0,6 kPa"},{"name":"nadciśnienie, ciecz","range":"od 6 MPa do 16 MPa","cmc":"0,025 % +1,6 kPa"},{"name":"nadciśnienie, ciecz","range":"od 16 MPa do 60 MPa","cmc":"0,025 % + 6 kPa"},{"name":"nadciśnienie, ciecz","range":"od 60 MPa do 100 MPa","cmc":"25 kPa"},{"name":"nadciśnienie, ciecz","range":"od 100 MPa do 250 MPa","cmc":"250 kPa"},{"name":"ciśnienie bezwzględne, gaz","range":"od 70 kPa do 100 kPa","cmc":"0,025 % + 60 Pa"},{"name":"ciśnienie bezwzględne, gaz","range":"od 0,1 MPa do 2 MPa","cmc":"0,025 % + 0,3 kPa"},{"name":"ciśnienie bezwzględne, gaz","range":"od 2 MPa do 6 MPa","cmc":"0,025 % + 0,7 kPa"},{"name":"ciśnienie bezwzględne, gaz","range":"od 6 MPa do 7 MPa","cmc":"1,5 kPa"},{"name":"ciśnienie bezwzględne, ciecz","range":"od 0,1 MPa do 6 MPa","cmc":"0,025 % +0,7 kPa"},{"name":"ciśnienie bezwzględne, ciecz","range":"od 6 MPa do 16 MPa","cmc":"0,025 % +1,7 kPa"},{"name":"ciśnienie bezwzględne, ciecz","range":"od 16 MPa do 60 MPa","cmc":"0,025 % + 6,1 kPa"},{"name":"ciśnienie barometryczne, gaz","range":"od 70 kPa do 120 kPa","cmc":"0,05 kPa"}],"parameters_en":[{"name":"positive gauge pressure, gas","range":"-100 kPa to -2 kPa","cmc":"0,025 % + 10 Pa"},{"name":"positive gauge pressure, gas","range":"-2 kPa to 2 kPa","cmc":"0,1 % + 1 digit"},{"name":"positive gauge pressure, gas","range":"2 kPa to 10 kPa","cmc":"0,025 % + 1 Pa"},{"name":"positive gauge pressure, gas","range":"10 kPa to 100 kPa","cmc":"0,025 % + 10 Pa"},{"name":"positive gauge pressure, gas","range":"0,1 MPa to 2 MPa","cmc":"0,025 % + 0,2 kPa"},{"name":"positive gauge pressure, gas","range":"2 MPa to 6 MPa","cmc":"0,025 % + 0,6 kPa"},{"name":"positive gauge pressure, gas","range":"6 MPa to 7 MPa","cmc":"1,4 kPa"},{"name":"positive gauge pressure, liquid","range":"0 MPa to 6 MPa","cmc":"0,025 % +0,6 kPa"},{"name":"positive gauge pressure, liquid","range":"6 MPa to 16 MPa","cmc":"0,025 % +1,6 kPa"},{"name":"positive gauge pressure, liquid","range":"16 MPa to 60 MPa","cmc":"0,025 % + 6 kPa"},{"name":"positive gauge pressure, liquid","range":"60 MPa to 100 MPa","cmc":"25 kPa"},{"name":"positive gauge pressure, liquid","range":"100 MPa to 250 MPa","cmc":"250 kPa"},{"name":"absolute pressure, gas","range":"70 kPa to 100 kPa","cmc":"0,025 % + 60 Pa"},{"name":"absolute pressure, gas","range":"0,1 MPa to 2 MPa","cmc":"0,025 % + 0,3 kPa"},{"name":"absolute pressure, gas","range":"2 MPa to 6 MPa","cmc":"0,025 % + 0,7 kPa"},{"name":"absolute pressure, gas","range":"6 MPa to 7 MPa","cmc":"1,5 kPa"},{"name":"absolute pressure, liquid","range":"0,1 MPa to 6 MPa","cmc":"0,025 % +0,7 kPa"},{"name":"absolute pressure, liquid","range":"6 MPa to 16 MPa","cmc":"0,025 % +1,7 kPa"},{"name":"absolute pressure, liquid","range":"16 MPa to 60 MPa","cmc":"0,025 % + 6,1 kPa"},{"name":"barometric pressure, gas","range":"70 kPa to 120 kPa","cmc":"0,05 kPa"}],"parameters_zh":[{"name":"表压，气体","range":"-100 kPa 至 -2 kPa","cmc":"0,025 % + 10 Pa"},{"name":"表压，气体","range":"-2 kPa 至 2 kPa","cmc":"0,1 % + 1 digit"},{"name":"表压，气体","range":"2 kPa 至 10 kPa","cmc":"0,025 % + 1 Pa"},{"name":"表压，气体","range":"10 kPa 至 100 kPa","cmc":"0,025 % + 10 Pa"},{"name":"表压，气体","range":"0,1 MPa 至 2 MPa","cmc":"0,025 % + 0,2 kPa"},{"name":"表压，气体","range":"2 MPa 至 6 MPa","cmc":"0,025 % + 0,6 kPa"},{"name":"表压，气体","range":"6 MPa 至 7 MPa","cmc":"1,4 kPa"},{"name":"表压，液体","range":"0 MPa 至 6 MPa","cmc":"0,025 % +0,6 kPa"},{"name":"表压，液体","range":"6 MPa 至 16 MPa","cmc":"0,025 % +1,6 kPa"},{"name":"表压，液体","range":"16 MPa 至 60 MPa","cmc":"0,025 % + 6 kPa"},{"name":"表压，液体","range":"60 MPa 至 100 MPa","cmc":"25 kPa"},{"name":"表压，液体","range":"100 MPa 至 250 MPa","cmc":"250 kPa"},{"name":"绝对压力，气体","range":"70 kPa 至 100 kPa","cmc":"0,025 % + 60 Pa"},{"name":"绝对压力，气体","range":"0,1 MPa 至 2 MPa","cmc":"0,025 % + 0,3 kPa"},{"name":"绝对压力，气体","range":"2 MPa 至 6 MPa","cmc":"0,025 % + 0,7 kPa"},{"name":"绝对压力，气体","range":"6 MPa 至 7 MPa","cmc":"1,5 kPa"},{"name":"绝对压力，液体","range":"0,1 MPa 至 6 MPa","cmc":"0,025 % +0,7 kPa"},{"name":"绝对压力，液体","range":"6 MPa 至 16 MPa","cmc":"0,025 % +1,7 kPa"},{"name":"绝对压力，液体","range":"16 MPa 至 60 MPa","cmc":"0,025 % + 6,1 kPa"},{"name":"大气压力，气体","range":"70 kPa 至 120 kPa","cmc":"0,05 kPa"}],"parameters_cs":[{"name":"přetlak, plyn","range":"-100 kPa až -2 kPa","cmc":"0,025 % + 10 Pa"},{"name":"přetlak, plyn","range":"-2 kPa až 2 kPa","cmc":"0,1 % + 1 digit"},{"name":"přetlak, plyn","range":"2 kPa až 10 kPa","cmc":"0,025 % + 1 Pa"},{"name":"přetlak, plyn","range":"10 kPa až 100 kPa","cmc":"0,025 % + 10 Pa"},{"name":"přetlak, plyn","range":"0,1 MPa až 2 MPa","cmc":"0,025 % + 0,2 kPa"},{"name":"přetlak, plyn","range":"2 MPa až 6 MPa","cmc":"0,025 % + 0,6 kPa"},{"name":"přetlak, plyn","range":"6 MPa až 7 MPa","cmc":"1,4 kPa"},{"name":"přetlak, kapalina","range":"0 MPa až 6 MPa","cmc":"0,025 % +0,6 kPa"},{"name":"přetlak, kapalina","range":"6 MPa až 16 MPa","cmc":"0,025 % +1,6 kPa"},{"name":"přetlak, kapalina","range":"16 MPa až 60 MPa","cmc":"0,025 % + 6 kPa"},{"name":"přetlak, kapalina","range":"60 MPa až 100 MPa","cmc":"25 kPa"},{"name":"přetlak, kapalina","range":"100 MPa až 250 MPa","cmc":"250 kPa"},{"name":"absolutní tlak, plyn","range":"70 kPa až 100 kPa","cmc":"0,025 % + 60 Pa"},{"name":"absolutní tlak, plyn","range":"0,1 MPa až 2 MPa","cmc":"0,025 % + 0,3 kPa"},{"name":"absolutní tlak, plyn","range":"2 MPa až 6 MPa","cmc":"0,025 % + 0,7 kPa"},{"name":"absolutní tlak, plyn","range":"6 MPa až 7 MPa","cmc":"1,5 kPa"},{"name":"absolutní tlak, kapalina","range":"0,1 MPa až 6 MPa","cmc":"0,025 % +0,7 kPa"},{"name":"absolutní tlak, kapalina","range":"6 MPa až 16 MPa","cmc":"0,025 % +1,7 kPa"},{"name":"absolutní tlak, kapalina","range":"16 MPa až 60 MPa","cmc":"0,025 % + 6,1 kPa"},{"name":"barometrický tlak, plyn","range":"70 kPa až 120 kPa","cmc":"0,05 kPa"}],"technique":"Porównanie z ciśnieniomierzem wzorcowym","technique_en":"Comparison with a reference pressure gauge","technique_zh":"与标准压力表比较","technique_cs":"Porovnání s etalonovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem wzorcowym"],"techniques_en":["Comparison with a reference pressure gauge"],"techniques_zh":["与标准压力表比较"],"techniques_cs":["Porovnání s etalonovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nnadciśnienie, gaz od -100 kPa do -2 kPa CMC 0,025 % + 10 Pa\nnadciśnienie, gaz od -2 kPa do 2 kPa CMC 0,1 % + 1 digit\nnadciśnienie, gaz od 2 kPa do 10 kPa CMC 0,025 % + 1 Pa\nnadciśnienie, gaz od 10 kPa do 100 kPa CMC 0,025 % + 10 Pa\nnadciśnienie, gaz od 0,1 MPa do 2 MPa CMC 0,025 % + 0,2 kPa\nnadciśnienie, gaz od 2 MPa do 6 MPa CMC 0,025 % + 0,6 kPa\nnadciśnienie, gaz od 6 MPa do 7 MPa CMC 1,4 kPa\nnadciśnienie, ciecz od 0 MPa do 6 MPa CMC 0,025 % +0,6 kPa\nnadciśnienie, ciecz od 6 MPa do 16 MPa CMC 0,025 % +1,6 kPa\nnadciśnienie, ciecz od 16 MPa do 60 MPa CMC 0,025 % + 6 kPa\nnadciśnienie, ciecz od 60 MPa do 100 MPa CMC 25 kPa\nnadciśnienie, ciecz od 100 MPa do 250 MPa CMC 250 kPa\nciśnienie bezwzględne, gaz od 70 kPa do 100 kPa CMC 0,025 % + 60 Pa\nciśnienie bezwzględne, gaz od 0,1 MPa do 2 MPa CMC 0,025 % + 0,3 kPa\nciśnienie bezwzględne, gaz od 2 MPa do 6 MPa CMC 0,025 % + 0,7 kPa\nciśnienie bezwzględne, gaz od 6 MPa do 7 MPa CMC 1,5 kPa\nciśnienie bezwzględne, ciecz od 0,1 MPa do 6 MPa CMC 0,025 % +0,7 kPa\nciśnienie bezwzględne, ciecz od 6 MPa do 16 MPa CMC 0,025 % +1,7 kPa\nciśnienie bezwzględne, ciecz od 16 MPa do 60 MPa CMC 0,025 % + 6,1 kPa\nciśnienie barometryczne, gaz od 70 kPa do 120 kPa CMC 0,05 kPa\nPorównanie z ciśnieniomierzem wzorcowym","reference":"KP-PB-55 KP-PB-56","norm_bases":["KP-PB-55","KP-PB-56"],"lab_section":"Uherský Brod","lab_section_en":"Uherský Brod","lab_section_zh":"乌赫尔斯基布罗德","lab_section_cs":"Uherský Brod","lab_address":"9. května 1182, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":"Ciśnienie wynikowe (bezwzględne) jest sumą ciśnienia względnego i barometrycznego. Niepewność wynikowa składa się z niepewności ciśnienia względnego i barometrycznego.","note_en":"The resulting pressure is the sum of relative and barometric pressure. The resulting uncertainty is made up of the uncertainty of relative and barometric pressure.","note_zh":"所得（绝对）压力为相对压力与大气压力之和。所得不确定度由相对压力和大气压力的不确定度构成。","note_cs":"Výsledný tlak je součtem relativního a barometrického tlaku. Výsledná nejistota je tvořena nejistotou relativního a barometrického tlaku","search_text":"Ciśnieniomierze sprężyste i elektromechaniczne Wzorcowanie – ciśnienie Porównanie z ciśnieniomierzem wzorcowym nadciśnienie, gaz od -100 kPa do -2 kPa CMC 0,025 % + 10 Pa nadciśnienie, gaz od -2 kPa do 2 kPa CMC 0,1 % + 1 digit nadciśnienie, gaz od 2 kPa do 10 kPa CMC 0,025 % + 1 Pa nadciśnienie, gaz od 10 kPa do 100 kPa CMC 0,025 % + 10 Pa nadciśnienie, gaz od 0,1 MPa do 2 MPa CMC 0,025 % + 0,2 kPa nadciśnienie, gaz od 2 MPa do 6 MPa CMC 0,025 % + 0,6 kPa nadciśnienie, gaz od 6 MPa do 7 MPa CMC 1,4 kPa nadciśnienie, ciecz od 0 MPa do 6 MPa CMC 0,025 % +0,6 kPa nadciśnienie, ciecz od 6 MPa do 16 MPa CMC 0,025 % +1,6 kPa nadciśnienie, ciecz od 16 MPa do 60 MPa CMC 0,025 % + 6 kPa nadciśnienie, ciecz od 60 MPa do 100 MPa CMC 25 kPa nadciśnienie, ciecz od 100 MPa do 250 MPa CMC 250 kPa ciśnienie bezwzględne, gaz od 70 kPa do 100 kPa CMC 0,025 % + 60 Pa ciśnienie bezwzględne, gaz od 0,1 MPa do 2 MPa CMC 0,025 % + 0,3 kPa ciśnienie bezwzględne, gaz od 2 MPa do 6 MPa CMC 0,025 % + 0,7 kPa ciśnienie bezwzględne, gaz od 6 MPa do 7 MPa CMC 1,5 kPa ciśnienie bezwzględne, ciecz od 0,1 MPa do 6 MPa CMC 0,025 % +0,7 kPa ciśnienie bezwzględne, ciecz od 6 MPa do 16 MPa CMC 0,025 % +1,7 kPa ciśnienie bezwzględne, ciecz od 16 MPa do 60 MPa CMC 0,025 % + 6,1 kPa ciśnienie barometryczne, gaz od 70 kPa do 120 kPa CMC 0,05 kPa Deformační a elektromechanické tlakoměry Kalibrace – tlak Porovnání s etalonovým tlakoměrem přetlak, plyn -100 kPa až -2 kPa CMC 0,025 % + 10 Pa přetlak, plyn -2 kPa až 2 kPa CMC 0,1 % + 1 digit přetlak, plyn 2 kPa až 10 kPa CMC 0,025 % + 1 Pa přetlak, plyn 10 kPa až 100 kPa CMC 0,025 % + 10 Pa přetlak, plyn 0,1 MPa až 2 MPa CMC 0,025 % + 0,2 kPa přetlak, plyn 2 MPa až 6 MPa CMC 0,025 % + 0,6 kPa přetlak, plyn 6 MPa až 7 MPa CMC 1,4 kPa přetlak, kapalina 0 MPa až 6 MPa CMC 0,025 % +0,6 kPa přetlak, kapalina 6 MPa až 16 MPa CMC 0,025 % +1,6 kPa přetlak, kapalina 16 MPa až 60 MPa CMC 0,025 % + 6 kPa přetlak, kapalina 60 MPa až 100 MPa CMC 25 kPa přetlak, kapalina 100 MPa až 250 MPa CMC 250 kPa absolutní tlak, plyn 70 kPa až 100 kPa CMC 0,025 % + 60 Pa absolutní tlak, plyn 0,1 MPa až 2 MPa CMC 0,025 % + 0,3 kPa absolutní tlak, plyn 2 MPa až 6 MPa CMC 0,025 % + 0,7 kPa absolutní tlak, plyn 6 MPa až 7 MPa CMC 1,5 kPa absolutní tlak, kapalina 0,1 MPa až 6 MPa CMC 0,025 % +0,7 kPa absolutní tlak, kapalina 6 MPa až 16 MPa CMC 0,025 % +1,7 kPa absolutní tlak, kapalina 16 MPa až 60 MPa CMC 0,025 % + 6,1 kPa barometrický tlak, plyn 70 kPa až 120 kPa CMC 0,05 kPa KP-PB-55 KP-PB-56 Cisnieniomierze sprezyste i elektromechaniczne Wzorcowanie – cisnienie Porownanie z cisnieniomierzem wzorcowym nadcisnienie, gaz od -100 kPa do -2 kPa CMC 0,025 % + 10 Pa nadcisnienie, gaz od -2 kPa do 2 kPa CMC 0,1 % + 1 digit nadcisnienie, gaz od 2 kPa do 10 kPa CMC 0,025 % + 1 Pa nadcisnienie, gaz od 10 kPa do 100 kPa CMC 0,025 % + 10 Pa nadcisnienie, gaz od 0,1 MPa do 2 MPa CMC 0,025 % + 0,2 kPa nadcisnienie, gaz od 2 MPa do 6 MPa CMC 0,025 % + 0,6 kPa nadcisnienie, gaz od 6 MPa do 7 MPa CMC 1,4 kPa nadcisnienie, ciecz od 0 MPa do 6 MPa CMC 0,025 % +0,6 kPa nadcisnienie, ciecz od 6 MPa do 16 MPa CMC 0,025 % +1,6 kPa nadcisnienie, ciecz od 16 MPa do 60 MPa CMC 0,025 % + 6 kPa nadcisnienie, ciecz od 60 MPa do 100 MPa CMC 25 kPa nadcisnienie, ciecz od 100 MPa do 250 MPa CMC 250 kPa cisnienie bezwzgledne, gaz od 70 kPa do 100 kPa CMC 0,025 % + 60 Pa cisnienie bezwzgledne, gaz od 0,1 MPa do 2 MPa CMC 0,025 % + 0,3 kPa cisnienie bezwzgledne, gaz od 2 MPa do 6 MPa CMC 0,025 % + 0,7 kPa cisnienie bezwzgledne, gaz od 6 MPa do 7 MPa CMC 1,5 kPa cisnienie bezwzgledne, ciecz od 0,1 MPa do 6 MPa CMC 0,025 % +0,7 kPa cisnienie bezwzgledne, ciecz od 6 MPa do 16 MPa CMC 0,025 % +1,7 kPa cisnienie bezwzgledne, ciecz od 16 MPa do 60 MPa CMC 0,025 % + 6,1 kPa cisnienie barometryczne, gaz od 70 kPa do 120 kPa CMC 0,05 kPa Deformacni a elektromechanicke tlakomery Kalibrace – tlak Porovnani s etalonovym tlakomerem pretlak, plyn -100 kPa az -2 kPa CMC 0,025 % + 10 Pa pretlak, plyn -2 kPa az 2 kPa CMC 0,1 % + 1 digit pretlak, plyn 2 kPa az 10 kPa CMC 0,025 % + 1 Pa pretlak, plyn 10 kPa az 100 kPa CMC 0,025 % + 10 Pa pretlak, plyn 0,1 MPa az 2 MPa CMC 0,025 % + 0,2 kPa pretlak, plyn 2 MPa az 6 MPa CMC 0,025 % + 0,6 kPa pretlak, plyn 6 MPa az 7 MPa CMC 1,4 kPa pretlak, kapalina 0 MPa az 6 MPa CMC 0,025 % +0,6 kPa pretlak, kapalina 6 MPa az 16 MPa CMC 0,025 % +1,6 kPa pretlak, kapalina 16 MPa az 60 MPa CMC 0,025 % + 6 kPa pretlak, kapalina 60 MPa az 100 MPa CMC 25 kPa pretlak, kapalina 100 MPa az 250 MPa CMC 250 kPa absolutni tlak, plyn 70 kPa az 100 kPa CMC 0,025 % + 60 Pa absolutni tlak, plyn 0,1 MPa az 2 MPa CMC 0,025 % + 0,3 kPa absolutni tlak, plyn 2 MPa az 6 MPa CMC 0,025 % + 0,7 kPa absolutni tlak, plyn 6 MPa az 7 MPa CMC 1,5 kPa absolutni tlak, kapalina 0,1 MPa az 6 MPa CMC 0,025 % +0,7 kPa absolutni tlak, kapalina 6 MPa az 16 MPa CMC 0,025 % +1,7 kPa absolutni tlak, kapalina 16 MPa az 60 MPa CMC 0,025 % + 6,1 kPa barometricky tlak, plyn 70 kPa az 120 kPa CMC 0,05 kPa KP-PB-55 KP-PB-56","search_en":"Mechanical pressure gauges and electromechanical manometers Calibration – pressure Comparison with a reference pressure gauge Uherský Brod CMC for the field of measured quantity: Pressure Comparison with a reference pressure gauge positive gauge pressure, gas positive gauge pressure, gas positive gauge pressure, gas positive gauge pressure, gas positive gauge pressure, gas positive gauge pressure, gas positive gauge pressure, gas positive gauge pressure, liquid positive gauge pressure, liquid positive gauge pressure, liquid positive gauge pressure, liquid positive gauge pressure, liquid absolute pressure, gas absolute pressure, gas absolute pressure, gas absolute pressure, gas absolute pressure, liquid absolute pressure, liquid absolute pressure, liquid barometric pressure, gas KP-PB-55 KP-PB-56","search_zh":"弹性式和机电式压力表 校准 – 压力 与标准压力表比较 乌赫尔斯基布罗德 被测量领域的CMC：压力 与标准压力表比较 表压，气体 表压，气体 表压，气体 表压，气体 表压，气体 表压，气体 表压，气体 表压，液体 表压，液体 表压，液体 表压，液体 表压，液体 绝对压力，气体 绝对压力，气体 绝对压力，气体 绝对压力，气体 绝对压力，液体 绝对压力，液体 绝对压力，液体 大气压力，气体 KP-PB-55 KP-PB-56","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod","methodology_de":"Kalibrierung – Druck","parameters_de":[{"name":"Überdruck, Gas","range":"von -100 kPa bis -2 kPa","cmc":"0,025 % + 10 Pa"},{"name":"Überdruck, Gas","range":"von -2 kPa bis 2 kPa","cmc":"0,1 % + 1 digit"},{"name":"Überdruck, Gas","range":"von 2 kPa bis 10 kPa","cmc":"0,025 % + 1 Pa"},{"name":"Überdruck, Gas","range":"von 10 kPa bis 100 kPa","cmc":"0,025 % + 10 Pa"},{"name":"Überdruck, Gas","range":"von 0,1 MPa bis 2 MPa","cmc":"0,025 % + 0,2 kPa"},{"name":"Überdruck, Gas","range":"von 2 MPa bis 6 MPa","cmc":"0,025 % + 0,6 kPa"},{"name":"Überdruck, Gas","range":"von 6 MPa bis 7 MPa","cmc":"1,4 kPa"},{"name":"Überdruck, Flüssigkeit","range":"von 0 MPa bis 6 MPa","cmc":"0,025 % +0,6 kPa"},{"name":"Überdruck, Flüssigkeit","range":"von 6 MPa bis 16 MPa","cmc":"0,025 % +1,6 kPa"},{"name":"Überdruck, Flüssigkeit","range":"von 16 MPa bis 60 MPa","cmc":"0,025 % + 6 kPa"},{"name":"Überdruck, Flüssigkeit","range":"von 60 MPa bis 100 MPa","cmc":"25 kPa"},{"name":"Überdruck, Flüssigkeit","range":"von 100 MPa bis 250 MPa","cmc":"250 kPa"},{"name":"Absolutdruck, Gas","range":"von 70 kPa bis 100 kPa","cmc":"0,025 % + 60 Pa"},{"name":"Absolutdruck, Gas","range":"von 0,1 MPa bis 2 MPa","cmc":"0,025 % + 0,3 kPa"},{"name":"Absolutdruck, Gas","range":"von 2 MPa bis 6 MPa","cmc":"0,025 % + 0,7 kPa"},{"name":"Absolutdruck, Gas","range":"von 6 MPa bis 7 MPa","cmc":"1,5 kPa"},{"name":"Absolutdruck, Flüssigkeit","range":"von 0,1 MPa bis 6 MPa","cmc":"0,025 % +0,7 kPa"},{"name":"Absolutdruck, Flüssigkeit","range":"von 6 MPa bis 16 MPa","cmc":"0,025 % +1,7 kPa"},{"name":"Absolutdruck, Flüssigkeit","range":"von 16 MPa bis 60 MPa","cmc":"0,025 % + 6,1 kPa"},{"name":"barometrischer Druck, Gas","range":"von 70 kPa bis 120 kPa","cmc":"0,05 kPa"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Druck","search_de":"Federmanometer und elektromechanische Druckmessgeräte Kalibrierung – Druck Vergleich mit einem Referenzdruckmessgerät Uherský Brod CMC für den Messgrößenbereich: Druck Vergleich mit einem Referenzdruckmessgerät Überdruck, Gas Überdruck, Gas Überdruck, Gas Überdruck, Gas Überdruck, Gas Überdruck, Gas Überdruck, Gas Überdruck, Flüssigkeit Überdruck, Flüssigkeit Überdruck, Flüssigkeit Überdruck, Flüssigkeit Überdruck, Flüssigkeit Absolutdruck, Gas Absolutdruck, Gas Absolutdruck, Gas Absolutdruck, Gas Absolutdruck, Flüssigkeit Absolutdruck, Flüssigkeit Absolutdruck, Flüssigkeit barometrischer Druck, Gas KP-PB-55 KP-PB-56","technique_de":"Vergleich mit einem Referenzdruckmessgerät","techniques_de":["Vergleich mit einem Referenzdruckmessgerät"],"test_object_de":"Federmanometer und elektromechanische Druckmessgeräte"},{"_id":"1a200939111923eff890ab85","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -100 °C do -60 °C","cmc":"0,04 °C"},{"name":"","range":"od -60 °C do 0 °C","cmc":"0,04 °C"},{"name":"","range":"od 0 °C do 50 °C","cmc":"0,03 °C"},{"name":"","range":"od 50 °C do 230 °C","cmc":"0,04 °C"},{"name":"","range":"od 230 °C do 660 °C","cmc":"0,05 °C"}],"parameters_en":[{"name":"","range":"-100 °C to -60 °C","cmc":"0,04 °C"},{"name":"","range":"-60 °C to 0 °C","cmc":"0,04 °C"},{"name":"","range":"from 0 °C to 50 °C","cmc":"0,03 °C"},{"name":"","range":"50 °C to 230 °C","cmc":"0,04 °C"},{"name":"","range":"230 °C to 660 °C","cmc":"0,05 °C"}],"parameters_zh":[{"name":"","range":"-100 °C 至 -60 °C","cmc":"0,04 °C"},{"name":"","range":"-60 °C 至 0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C 至 50 °C","cmc":"0,03 °C"},{"name":"","range":"50 °C 至 230 °C","cmc":"0,04 °C"},{"name":"","range":"230 °C 至 660 °C","cmc":"0,05 °C"}],"parameters_cs":[{"name":"","range":"-100 °C až -60 °C","cmc":"0,04 °C"},{"name":"","range":"-60 °C až 0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C až 50 °C","cmc":"0,03 °C"},{"name":"","range":"50 °C až 230 °C","cmc":"0,04 °C"},{"name":"","range":"230 °C až 660 °C","cmc":"0,05 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym","technique_en":"Comparison using a reference resistance thermometer","technique_zh":"与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym"],"techniques_en":["Comparison using a reference resistance thermometer"],"techniques_zh":["与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -100 °C do -60 °C CMC 0,04 °C\nod -60 °C do 0 °C CMC 0,04 °C\nod 0 °C do 50 °C CMC 0,03 °C\nod 50 °C do 230 °C CMC 0,04 °C\nod 230 °C do 660 °C CMC 0,05 °C\nPorównanie z wzorcowym termometrem rezystancyjnym","reference":"KP-PB-51","norm_bases":["KP-PB-51"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym od -100 °C do -60 °C CMC 0,04 °C od -60 °C do 0 °C CMC 0,04 °C od 0 °C do 50 °C CMC 0,03 °C od 50 °C do 230 °C CMC 0,04 °C od 230 °C do 660 °C CMC 0,05 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem -100 °C až -60 °C CMC 0,04 °C -60 °C až 0 °C CMC 0,04 °C 0 °C až 50 °C CMC 0,03 °C 50 °C až 230 °C CMC 0,04 °C 230 °C až 660 °C CMC 0,05 °C KP-PB-51 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym od -100 °C do -60 °C CMC 0,04 °C od -60 °C do 0 °C CMC 0,04 °C od 0 °C do 50 °C CMC 0,03 °C od 50 °C do 230 °C CMC 0,04 °C od 230 °C do 660 °C CMC 0,05 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem -100 °C az -60 °C CMC 0,04 °C -60 °C az 0 °C CMC 0,04 °C 0 °C az 50 °C CMC 0,03 °C 50 °C az 230 °C CMC 0,04 °C 230 °C az 660 °C CMC 0,05 °C KP-PB-51","search_en":"Direct-indicating thermometers Calibration – temperature Comparison using a reference resistance thermometer Mladá Boleslav CMC for the field of measured quantity: Temperature Comparison using a reference resistance thermometer KP-PB-51","search_zh":"直读式温度计 校准 – 温度 与标准电阻温度计比较 姆拉达-博莱斯拉夫 被测量领域的CMC：温度 与标准电阻温度计比较 KP-PB-51","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von -100 °C bis -60 °C","cmc":"0,04 °C"},{"name":"","range":"von -60 °C bis 0 °C","cmc":"0,04 °C"},{"name":"","range":"von 0 °C bis 50 °C","cmc":"0,03 °C"},{"name":"","range":"von 50 °C bis 230 °C","cmc":"0,04 °C"},{"name":"","range":"von 230 °C bis 660 °C","cmc":"0,05 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Direkt anzeigende Thermometer Kalibrierung – Temperatur Vergleich mit Referenz-Widerstandsthermometer Mladá Boleslav CMC für den Messgrößenbereich: Temperatur Vergleich mit Referenz-Widerstandsthermometer KP-PB-51","technique_de":"Vergleich mit Referenz-Widerstandsthermometer","techniques_de":["Vergleich mit Referenz-Widerstandsthermometer"],"test_object_de":"Direkt anzeigende Thermometer"},{"_id":"d82c83ebeff989199199bc28","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -100 °C do -60 °C","cmc":"0,04 °C"},{"name":"","range":"od -60 °C do 0 °C","cmc":"0,04 °C"},{"name":"","range":"od 0 °C do 50 °C","cmc":"0,03 °C"},{"name":"","range":"od 50 °C do 230 °C","cmc":"0,04 °C"},{"name":"","range":"od 230 °C do 660 °C","cmc":"0,05 °C"}],"parameters_en":[{"name":"","range":"-100 °C to -60 °C","cmc":"0,04 °C"},{"name":"","range":"-60 °C to 0 °C","cmc":"0,04 °C"},{"name":"","range":"from 0 °C to 50 °C","cmc":"0,03 °C"},{"name":"","range":"50 °C to 230 °C","cmc":"0,04 °C"},{"name":"","range":"230 °C to 660 °C","cmc":"0,05 °C"}],"parameters_zh":[{"name":"","range":"-100 °C 至 -60 °C","cmc":"0,04 °C"},{"name":"","range":"-60 °C 至 0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C 至 50 °C","cmc":"0,03 °C"},{"name":"","range":"50 °C 至 230 °C","cmc":"0,04 °C"},{"name":"","range":"230 °C 至 660 °C","cmc":"0,05 °C"}],"parameters_cs":[{"name":"","range":"-100 °C až -60 °C","cmc":"0,04 °C"},{"name":"","range":"-60 °C až 0 °C","cmc":"0,04 °C"},{"name":"","range":"0 °C až 50 °C","cmc":"0,03 °C"},{"name":"","range":"50 °C až 230 °C","cmc":"0,04 °C"},{"name":"","range":"230 °C až 660 °C","cmc":"0,05 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym","technique_en":"Comparison using a reference resistance thermometer","technique_zh":"与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym"],"techniques_en":["Comparison using a reference resistance thermometer"],"techniques_zh":["与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -100 °C do -60 °C CMC 0,04 °C\nod -60 °C do 0 °C CMC 0,04 °C\nod 0 °C do 50 °C CMC 0,03 °C\nod 50 °C do 230 °C CMC 0,04 °C\nod 230 °C do 660 °C CMC 0,05 °C\nPorównanie z wzorcowym termometrem rezystancyjnym","reference":"KP-PB-51","norm_bases":["KP-PB-51"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym od -100 °C do -60 °C CMC 0,04 °C od -60 °C do 0 °C CMC 0,04 °C od 0 °C do 50 °C CMC 0,03 °C od 50 °C do 230 °C CMC 0,04 °C od 230 °C do 660 °C CMC 0,05 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem -100 °C až -60 °C CMC 0,04 °C -60 °C až 0 °C CMC 0,04 °C 0 °C až 50 °C CMC 0,03 °C 50 °C až 230 °C CMC 0,04 °C 230 °C až 660 °C CMC 0,05 °C KP-PB-51 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym od -100 °C do -60 °C CMC 0,04 °C od -60 °C do 0 °C CMC 0,04 °C od 0 °C do 50 °C CMC 0,03 °C od 50 °C do 230 °C CMC 0,04 °C od 230 °C do 660 °C CMC 0,05 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem -100 °C az -60 °C CMC 0,04 °C -60 °C az 0 °C CMC 0,04 °C 0 °C az 50 °C CMC 0,03 °C 50 °C az 230 °C CMC 0,04 °C 230 °C az 660 °C CMC 0,05 °C KP-PB-51","search_en":"Direct-indicating thermometers Calibration – temperature Comparison using a reference resistance thermometer Uherský Brod II CMC for the field of measured quantity: Temperature Comparison using a reference resistance thermometer KP-PB-51","search_zh":"直读式温度计 校准 – 温度 与标准电阻温度计比较 乌赫尔斯基布罗德 II 被测量领域的CMC：温度 与标准电阻温度计比较 KP-PB-51","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von -100 °C bis -60 °C","cmc":"0,04 °C"},{"name":"","range":"von -60 °C bis 0 °C","cmc":"0,04 °C"},{"name":"","range":"von 0 °C bis 50 °C","cmc":"0,03 °C"},{"name":"","range":"von 50 °C bis 230 °C","cmc":"0,04 °C"},{"name":"","range":"von 230 °C bis 660 °C","cmc":"0,05 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Direkt anzeigende Thermometer Kalibrierung – Temperatur Vergleich mit Referenz-Widerstandsthermometer Uherský Brod II CMC für den Messgrößenbereich: Temperatur Vergleich mit Referenz-Widerstandsthermometer KP-PB-51","technique_de":"Vergleich mit Referenz-Widerstandsthermometer","techniques_de":["Vergleich mit Referenz-Widerstandsthermometer"],"test_object_de":"Direkt anzeigende Thermometer"},{"_id":"3edd70fabbd5f3dd59cb38df","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 660 °C do 700 °C","cmc":"1,1 °C"},{"name":"","range":"od 700 °C do 1000 °C","cmc":"1,2 °C"},{"name":"","range":"od 1000 °C do 1100 °C","cmc":"1,2 °C"},{"name":"","range":"od 1100 °C do 1200 °C","cmc":"1,4 °C"},{"name":"","range":"od 1200 °C do 1500 °C","cmc":"2,4 °C"},{"name":"","range":"od 1500 °C do 1600 °C","cmc":"2,9 °C"}],"parameters_en":[{"name":"","range":"660 °C to 700 °C","cmc":"1,1 °C"},{"name":"","range":"700 °C to 1000 °C","cmc":"1,2 °C"},{"name":"","range":"from 1000 °C to 1100 °C","cmc":"1,2 °C"},{"name":"","range":"from 1100 °C to 1200 °C","cmc":"1,4 °C"},{"name":"","range":"from 1200 °C to 1500 °C","cmc":"2,4 °C"},{"name":"","range":"1500 °C to 1600 °C","cmc":"2,9 °C"}],"parameters_zh":[{"name":"","range":"660 °C 至 700 °C","cmc":"1,1 °C"},{"name":"","range":"700 °C 至 1000 °C","cmc":"1,2 °C"},{"name":"","range":"1000 °C 至 1100 °C","cmc":"1,2 °C"},{"name":"","range":"1100 °C 至 1200 °C","cmc":"1,4 °C"},{"name":"","range":"1200 °C 至 1500 °C","cmc":"2,4 °C"},{"name":"","range":"1500 °C 至 1600 °C","cmc":"2,9 °C"}],"parameters_cs":[{"name":"","range":"660 °C až 700 °C","cmc":"1,1 °C"},{"name":"","range":"700 °C až 1000 °C","cmc":"1,2 °C"},{"name":"","range":"1000 °C až 1100 °C","cmc":"1,2 °C"},{"name":"","range":"1100 °C až 1200 °C","cmc":"1,4 °C"},{"name":"","range":"1200 °C až 1500 °C","cmc":"2,4 °C"},{"name":"","range":"1500 °C až 1600 °C","cmc":"2,9 °C"}],"technique":"Porównanie z wzorcową termoparą","technique_en":"Comparison with a reference thermocouple","technique_zh":"与标准热电偶比较","technique_cs":"Porovnání s etalonovým termoelektrickým článkem","techniques":["Porównanie z wzorcową termoparą"],"techniques_en":["Comparison with a reference thermocouple"],"techniques_zh":["与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým článkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 660 °C do 700 °C CMC 1,1 °C\nod 700 °C do 1000 °C CMC 1,2 °C\nod 1000 °C do 1100 °C CMC 1,2 °C\nod 1100 °C do 1200 °C CMC 1,4 °C\nod 1200 °C do 1500 °C CMC 2,4 °C\nod 1500 °C do 1600 °C CMC 2,9 °C\nPorównanie z wzorcową termoparą","reference":"KP-PB-51","norm_bases":["KP-PB-51"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcową termoparą od 660 °C do 700 °C CMC 1,1 °C od 700 °C do 1000 °C CMC 1,2 °C od 1000 °C do 1100 °C CMC 1,2 °C od 1100 °C do 1200 °C CMC 1,4 °C od 1200 °C do 1500 °C CMC 2,4 °C od 1500 °C do 1600 °C CMC 2,9 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým termoelektrickým článkem 660 °C až 700 °C CMC 1,1 °C 700 °C až 1000 °C CMC 1,2 °C 1000 °C až 1100 °C CMC 1,2 °C 1100 °C až 1200 °C CMC 1,4 °C 1200 °C až 1500 °C CMC 2,4 °C 1500 °C až 1600 °C CMC 2,9 °C KP-PB-51 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowa termopara od 660 °C do 700 °C CMC 1,1 °C od 700 °C do 1000 °C CMC 1,2 °C od 1000 °C do 1100 °C CMC 1,2 °C od 1100 °C do 1200 °C CMC 1,4 °C od 1200 °C do 1500 °C CMC 2,4 °C od 1500 °C do 1600 °C CMC 2,9 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym termoelektrickym clankem 660 °C az 700 °C CMC 1,1 °C 700 °C az 1000 °C CMC 1,2 °C 1000 °C az 1100 °C CMC 1,2 °C 1100 °C az 1200 °C CMC 1,4 °C 1200 °C az 1500 °C CMC 2,4 °C 1500 °C az 1600 °C CMC 2,9 °C KP-PB-51","search_en":"Direct-indicating thermometers Calibration – temperature Comparison with a reference thermocouple Mladá Boleslav CMC for the field of measured quantity: Temperature Comparison with a reference thermocouple KP-PB-51","search_zh":"直读式温度计 校准 – 温度 与标准热电偶比较 姆拉达-博莱斯拉夫 被测量领域的CMC：温度 与标准热电偶比较 KP-PB-51","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von 660 °C bis 700 °C","cmc":"1,1 °C"},{"name":"","range":"von 700 °C bis 1000 °C","cmc":"1,2 °C"},{"name":"","range":"von 1000 °C bis 1100 °C","cmc":"1,2 °C"},{"name":"","range":"von 1100 °C bis 1200 °C","cmc":"1,4 °C"},{"name":"","range":"von 1200 °C bis 1500 °C","cmc":"2,4 °C"},{"name":"","range":"von 1500 °C bis 1600 °C","cmc":"2,9 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Direkt anzeigende Thermometer Kalibrierung – Temperatur Vergleich mit Referenzthermoelement Mladá Boleslav CMC für den Messgrößenbereich: Temperatur Vergleich mit Referenzthermoelement KP-PB-51","technique_de":"Vergleich mit Referenzthermoelement","techniques_de":["Vergleich mit Referenzthermoelement"],"test_object_de":"Direkt anzeigende Thermometer"},{"_id":"4c0b16fb1688b0d21f3839c5","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 660 °C do 700 °C","cmc":"1,1 °C"},{"name":"","range":"od 700 °C do 1000 °C","cmc":"1,2 °C"},{"name":"","range":"od 1000 °C do 1100 °C","cmc":"1,2 °C"},{"name":"","range":"od 1100 °C do 1200 °C","cmc":"1,4 °C"},{"name":"","range":"od 1200 °C do 1500 °C","cmc":"2,4 °C"},{"name":"","range":"od 1500 °C do 1600 °C","cmc":"2,9 °C"}],"parameters_en":[{"name":"","range":"660 °C to 700 °C","cmc":"1,1 °C"},{"name":"","range":"700 °C to 1000 °C","cmc":"1,2 °C"},{"name":"","range":"from 1000 °C to 1100 °C","cmc":"1,2 °C"},{"name":"","range":"from 1100 °C to 1200 °C","cmc":"1,4 °C"},{"name":"","range":"from 1200 °C to 1500 °C","cmc":"2,4 °C"},{"name":"","range":"1500 °C to 1600 °C","cmc":"2,9 °C"}],"parameters_zh":[{"name":"","range":"660 °C 至 700 °C","cmc":"1,1 °C"},{"name":"","range":"700 °C 至 1000 °C","cmc":"1,2 °C"},{"name":"","range":"1000 °C 至 1100 °C","cmc":"1,2 °C"},{"name":"","range":"1100 °C 至 1200 °C","cmc":"1,4 °C"},{"name":"","range":"1200 °C 至 1500 °C","cmc":"2,4 °C"},{"name":"","range":"1500 °C 至 1600 °C","cmc":"2,9 °C"}],"parameters_cs":[{"name":"","range":"660 °C až 700 °C","cmc":"1,1 °C"},{"name":"","range":"700 °C až 1000 °C","cmc":"1,2 °C"},{"name":"","range":"1000 °C až 1100 °C","cmc":"1,2 °C"},{"name":"","range":"1100 °C až 1200 °C","cmc":"1,4 °C"},{"name":"","range":"1200 °C až 1500 °C","cmc":"2,4 °C"},{"name":"","range":"1500 °C až 1600 °C","cmc":"2,9 °C"}],"technique":"Porównanie z wzorcową termoparą","technique_en":"Comparison with a reference thermocouple","technique_zh":"与标准热电偶比较","technique_cs":"Porovnání s etalonovým termoelektrickým článkem","techniques":["Porównanie z wzorcową termoparą"],"techniques_en":["Comparison with a reference thermocouple"],"techniques_zh":["与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým článkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 660 °C do 700 °C CMC 1,1 °C\nod 700 °C do 1000 °C CMC 1,2 °C\nod 1000 °C do 1100 °C CMC 1,2 °C\nod 1100 °C do 1200 °C CMC 1,4 °C\nod 1200 °C do 1500 °C CMC 2,4 °C\nod 1500 °C do 1600 °C CMC 2,9 °C\nPorównanie z wzorcową termoparą","reference":"KP-PB-51","norm_bases":["KP-PB-51"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcową termoparą od 660 °C do 700 °C CMC 1,1 °C od 700 °C do 1000 °C CMC 1,2 °C od 1000 °C do 1100 °C CMC 1,2 °C od 1100 °C do 1200 °C CMC 1,4 °C od 1200 °C do 1500 °C CMC 2,4 °C od 1500 °C do 1600 °C CMC 2,9 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým termoelektrickým článkem 660 °C až 700 °C CMC 1,1 °C 700 °C až 1000 °C CMC 1,2 °C 1000 °C až 1100 °C CMC 1,2 °C 1100 °C až 1200 °C CMC 1,4 °C 1200 °C až 1500 °C CMC 2,4 °C 1500 °C až 1600 °C CMC 2,9 °C KP-PB-51 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowa termopara od 660 °C do 700 °C CMC 1,1 °C od 700 °C do 1000 °C CMC 1,2 °C od 1000 °C do 1100 °C CMC 1,2 °C od 1100 °C do 1200 °C CMC 1,4 °C od 1200 °C do 1500 °C CMC 2,4 °C od 1500 °C do 1600 °C CMC 2,9 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym termoelektrickym clankem 660 °C az 700 °C CMC 1,1 °C 700 °C az 1000 °C CMC 1,2 °C 1000 °C az 1100 °C CMC 1,2 °C 1100 °C az 1200 °C CMC 1,4 °C 1200 °C az 1500 °C CMC 2,4 °C 1500 °C az 1600 °C CMC 2,9 °C KP-PB-51","search_en":"Direct-indicating thermometers Calibration – temperature Comparison with a reference thermocouple Uherský Brod II CMC for the field of measured quantity: Temperature Comparison with a reference thermocouple KP-PB-51","search_zh":"直读式温度计 校准 – 温度 与标准热电偶比较 乌赫尔斯基布罗德 II 被测量领域的CMC：温度 与标准热电偶比较 KP-PB-51","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von 660 °C bis 700 °C","cmc":"1,1 °C"},{"name":"","range":"von 700 °C bis 1000 °C","cmc":"1,2 °C"},{"name":"","range":"von 1000 °C bis 1100 °C","cmc":"1,2 °C"},{"name":"","range":"von 1100 °C bis 1200 °C","cmc":"1,4 °C"},{"name":"","range":"von 1200 °C bis 1500 °C","cmc":"2,4 °C"},{"name":"","range":"von 1500 °C bis 1600 °C","cmc":"2,9 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Direkt anzeigende Thermometer Kalibrierung – Temperatur Vergleich mit Referenzthermoelement Uherský Brod II CMC für den Messgrößenbereich: Temperatur Vergleich mit Referenzthermoelement KP-PB-51","technique_de":"Vergleich mit Referenzthermoelement","techniques_de":["Vergleich mit Referenzthermoelement"],"test_object_de":"Direkt anzeigende Thermometer"},{"_id":"98e7a161871974fe2b0af7eb","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Termometry bezpośrednio wskazujące – tory pomiarowe temperatury – na zewnątrz (u klienta)","test_object_en":"Direct indicating thermometers – temperature measuring chains – externally","test_object_zh":"直读式温度计 – 温度测量链 – 外部（现场）","test_object_cs":"Přímoukazující teploměry – teplotní řetězce – externě","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -100 °C do 230 °C","cmc":"0,2 °C"},{"name":"","range":"od 230 °C do 660 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"-100 °C to 230 °C","cmc":"0,2 °C"},{"name":"","range":"230 °C to 660 °C","cmc":"0,3 °C"}],"parameters_zh":[{"name":"","range":"-100 °C 至 230 °C","cmc":"0,2 °C"},{"name":"","range":"230 °C 至 660 °C","cmc":"0,3 °C"}],"parameters_cs":[{"name":"","range":"-100 °C až 230 °C","cmc":"0,2 °C"},{"name":"","range":"230 °C až 660 °C","cmc":"0,3 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym","technique_en":"Comparison using a reference resistance thermometer","technique_zh":"与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym"],"techniques_en":["Comparison using a reference resistance thermometer"],"techniques_zh":["与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -100 °C do 230 °C CMC 0,2 °C\nod 230 °C do 660 °C CMC 0,3 °C\nPorównanie z wzorcowym termometrem rezystancyjnym","reference":"KP-PB-51","norm_bases":["KP-PB-51"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące – tory pomiarowe temperatury – na zewnątrz (u klienta) Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym od -100 °C do 230 °C CMC 0,2 °C od 230 °C do 660 °C CMC 0,3 °C Přímoukazující teploměry – teplotní řetězce – externě Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem -100 °C až 230 °C CMC 0,2 °C 230 °C až 660 °C CMC 0,3 °C KP-PB-51 Termometry bezposrednio wskazujace – tory pomiarowe temperatury – na zewnatrz (u klienta) Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym od -100 °C do 230 °C CMC 0,2 °C od 230 °C do 660 °C CMC 0,3 °C Primoukazujici teplomery – teplotni retezce – externe Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem -100 °C az 230 °C CMC 0,2 °C 230 °C az 660 °C CMC 0,3 °C KP-PB-51","search_en":"Direct indicating thermometers – temperature measuring chains – externally Calibration – temperature Comparison using a reference resistance thermometer Uherský Brod II CMC for the field of measured quantity: Temperature Comparison using a reference resistance thermometer KP-PB-51","search_zh":"直读式温度计 – 温度测量链 – 外部（现场） 校准 – 温度 与标准电阻温度计比较 乌赫尔斯基布罗德 II 被测量领域的CMC：温度 与标准电阻温度计比较 KP-PB-51","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von -100 °C bis 230 °C","cmc":"0,2 °C"},{"name":"","range":"von 230 °C bis 660 °C","cmc":"0,3 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Direkt anzeigende Thermometer – Temperaturmessketten – extern (beim Kunden) Kalibrierung – Temperatur Vergleich mit Referenz-Widerstandsthermometer Uherský Brod II CMC für den Messgrößenbereich: Temperatur Vergleich mit Referenz-Widerstandsthermometer KP-PB-51","technique_de":"Vergleich mit Referenz-Widerstandsthermometer","techniques_de":["Vergleich mit Referenz-Widerstandsthermometer"],"test_object_de":"Direkt anzeigende Thermometer – Temperaturmessketten – extern (beim Kunden)"},{"_id":"eb724d9762782edaab78f700","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Termometry bezpośrednio wskazujące – tory pomiarowe temperatury – na zewnątrz (u klienta)","test_object_en":"Direct indicating thermometers – temperature measuring chains – externally","test_object_zh":"直读式温度计 – 温度测量链 – 外部（现场）","test_object_cs":"Přímoukazující teploměry – teplotní řetězce – externě","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 660 °C do 700 °C","cmc":"1,1 °C"},{"name":"","range":"od 700 °C do 1000 °C","cmc":"2,1 °C"},{"name":"","range":"od 1000 °C do 1100 °C","cmc":"2,2 °C"},{"name":"","range":"od 1100 °C do 1200 °C","cmc":"2,3 °C"},{"name":"","range":"od 1200 °C do 1500 °C","cmc":"2,9 °C"},{"name":"","range":"od 1500 °C do 1600 °C","cmc":"3,4 °C"}],"parameters_en":[{"name":"","range":"660 °C to 700 °C","cmc":"1,1 °C"},{"name":"","range":"700 °C to 1000 °C","cmc":"2,1 °C"},{"name":"","range":"from 1000 °C to 1100 °C","cmc":"2,2 °C"},{"name":"","range":"from 1100 °C to 1200 °C","cmc":"2,3 °C"},{"name":"","range":"from 1200 °C to 1500 °C","cmc":"2,9 °C"},{"name":"","range":"1500 °C to 1600 °C","cmc":"3,4 °C"}],"parameters_zh":[{"name":"","range":"660 °C 至 700 °C","cmc":"1,1 °C"},{"name":"","range":"700 °C 至 1000 °C","cmc":"2,1 °C"},{"name":"","range":"1000 °C 至 1100 °C","cmc":"2,2 °C"},{"name":"","range":"1100 °C 至 1200 °C","cmc":"2,3 °C"},{"name":"","range":"1200 °C 至 1500 °C","cmc":"2,9 °C"},{"name":"","range":"1500 °C 至 1600 °C","cmc":"3,4 °C"}],"parameters_cs":[{"name":"","range":"660 °C až 700 °C","cmc":"1,1 °C"},{"name":"","range":"700 °C až 1000 °C","cmc":"2,1 °C"},{"name":"","range":"1000 °C až 1100 °C","cmc":"2,2 °C"},{"name":"","range":"1100 °C až 1200 °C","cmc":"2,3 °C"},{"name":"","range":"1200 °C až 1500 °C","cmc":"2,9 °C"},{"name":"","range":"1500 °C až 1600 °C","cmc":"3,4 °C"}],"technique":"Porównanie z wzorcową termoparą","technique_en":"Comparison with a reference thermocouple","technique_zh":"与标准热电偶比较","technique_cs":"Porovnání s etalonovým termoelektrickým článkem","techniques":["Porównanie z wzorcową termoparą"],"techniques_en":["Comparison with a reference thermocouple"],"techniques_zh":["与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým článkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 660 °C do 700 °C CMC 1,1 °C\nod 700 °C do 1000 °C CMC 2,1 °C\nod 1000 °C do 1100 °C CMC 2,2 °C\nod 1100 °C do 1200 °C CMC 2,3 °C\nod 1200 °C do 1500 °C CMC 2,9 °C\nod 1500 °C do 1600 °C CMC 3,4 °C\nPorównanie z wzorcową termoparą","reference":"KP-PB-51","norm_bases":["KP-PB-51"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące – tory pomiarowe temperatury – na zewnątrz (u klienta) Wzorcowanie – temperatura Porównanie z wzorcową termoparą od 660 °C do 700 °C CMC 1,1 °C od 700 °C do 1000 °C CMC 2,1 °C od 1000 °C do 1100 °C CMC 2,2 °C od 1100 °C do 1200 °C CMC 2,3 °C od 1200 °C do 1500 °C CMC 2,9 °C od 1500 °C do 1600 °C CMC 3,4 °C Přímoukazující teploměry – teplotní řetězce – externě Kalibrace – teplota Porovnání s etalonovým termoelektrickým článkem 660 °C až 700 °C CMC 1,1 °C 700 °C až 1000 °C CMC 2,1 °C 1000 °C až 1100 °C CMC 2,2 °C 1100 °C až 1200 °C CMC 2,3 °C 1200 °C až 1500 °C CMC 2,9 °C 1500 °C až 1600 °C CMC 3,4 °C KP-PB-51 Termometry bezposrednio wskazujace – tory pomiarowe temperatury – na zewnatrz (u klienta) Wzorcowanie – temperatura Porownanie z wzorcowa termopara od 660 °C do 700 °C CMC 1,1 °C od 700 °C do 1000 °C CMC 2,1 °C od 1000 °C do 1100 °C CMC 2,2 °C od 1100 °C do 1200 °C CMC 2,3 °C od 1200 °C do 1500 °C CMC 2,9 °C od 1500 °C do 1600 °C CMC 3,4 °C Primoukazujici teplomery – teplotni retezce – externe Kalibrace – teplota Porovnani s etalonovym termoelektrickym clankem 660 °C az 700 °C CMC 1,1 °C 700 °C az 1000 °C CMC 2,1 °C 1000 °C az 1100 °C CMC 2,2 °C 1100 °C az 1200 °C CMC 2,3 °C 1200 °C az 1500 °C CMC 2,9 °C 1500 °C az 1600 °C CMC 3,4 °C KP-PB-51","search_en":"Direct indicating thermometers – temperature measuring chains – externally Calibration – temperature Comparison with a reference thermocouple Uherský Brod II CMC for the field of measured quantity: Temperature Comparison with a reference thermocouple KP-PB-51","search_zh":"直读式温度计 – 温度测量链 – 外部（现场） 校准 – 温度 与标准热电偶比较 乌赫尔斯基布罗德 II 被测量领域的CMC：温度 与标准热电偶比较 KP-PB-51","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von 660 °C bis 700 °C","cmc":"1,1 °C"},{"name":"","range":"von 700 °C bis 1000 °C","cmc":"2,1 °C"},{"name":"","range":"von 1000 °C bis 1100 °C","cmc":"2,2 °C"},{"name":"","range":"von 1100 °C bis 1200 °C","cmc":"2,3 °C"},{"name":"","range":"von 1200 °C bis 1500 °C","cmc":"2,9 °C"},{"name":"","range":"von 1500 °C bis 1600 °C","cmc":"3,4 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Direkt anzeigende Thermometer – Temperaturmessketten – extern (beim Kunden) Kalibrierung – Temperatur Vergleich mit Referenzthermoelement Uherský Brod II CMC für den Messgrößenbereich: Temperatur Vergleich mit Referenzthermoelement KP-PB-51","technique_de":"Vergleich mit Referenzthermoelement","techniques_de":["Vergleich mit Referenzthermoelement"],"test_object_de":"Direkt anzeigende Thermometer – Temperaturmessketten – extern (beim Kunden)"},{"_id":"0c2633651bd157bab1a1e822","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"3","test_object":"Temperatura – termometry bezstykowe","test_object_en":"Temperature – contactless thermometers","test_object_zh":"温度 – 非接触式温度计","test_object_cs":"Teplota – bezkontaktní teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -20 °C do 0 °C","cmc":"1,2 °C"},{"name":"","range":"od 0 °C do 50 °C","cmc":"1,3 °C"},{"name":"","range":"od 50 °C do 100 °C","cmc":"1,4 °C"},{"name":"","range":"od 100 °C do 200 °C","cmc":"1,9 °C"},{"name":"","range":"od 200 °C do 300 °C","cmc":"2,8 °C"},{"name":"","range":"od 300 °C do 400 °C","cmc":"3,4 °C"},{"name":"","range":"od 400 °C do 500 °C","cmc":"3,6 °C"},{"name":"","range":"od 500 °C do 600 °C","cmc":"3,9 °C"},{"name":"","range":"od 600 °C do 800 °C","cmc":"5,0 °C"},{"name":"","range":"od 800 °C do 1000 °C","cmc":"6,1 °C"},{"name":"","range":"od 1000 °C do 1200 °C","cmc":"7,3 °C"}],"parameters_en":[{"name":"","range":"from -20 °C to 0 °C","cmc":"1,2 °C"},{"name":"","range":"from 0 °C to 50 °C","cmc":"1,3 °C"},{"name":"","range":"from 50 °C to 100 °C","cmc":"1,4 °C"},{"name":"","range":"from 100 °C to 200 °C","cmc":"1,9 °C"},{"name":"","range":"from 200 °C to 300 °C","cmc":"2,8 °C"},{"name":"","range":"from 300 °C to 400 °C","cmc":"3,4 °C"},{"name":"","range":"from 400 °C to 500 °C","cmc":"3,6 °C"},{"name":"","range":"from 500 °C to 600 °C","cmc":"3,9 °C"},{"name":"","range":"from 600 °C to 800 °C","cmc":"5,0 °C"},{"name":"","range":"from 800 °C to 1000 °C","cmc":"6,1 °C"},{"name":"","range":"from 1000 °C to 1200 °C","cmc":"7,3 °C"}],"parameters_zh":[{"name":"","range":"-20 °C 至 0 °C","cmc":"1,2 °C"},{"name":"","range":"0 °C 至 50 °C","cmc":"1,3 °C"},{"name":"","range":"50 °C 至 100 °C","cmc":"1,4 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"1,9 °C"},{"name":"","range":"200 °C 至 300 °C","cmc":"2,8 °C"},{"name":"","range":"300 °C 至 400 °C","cmc":"3,4 °C"},{"name":"","range":"400 °C 至 500 °C","cmc":"3,6 °C"},{"name":"","range":"500 °C 至 600 °C","cmc":"3,9 °C"},{"name":"","range":"600 °C 至 800 °C","cmc":"5,0 °C"},{"name":"","range":"800 °C 至 1000 °C","cmc":"6,1 °C"},{"name":"","range":"1000 °C 至 1200 °C","cmc":"7,3 °C"}],"parameters_cs":[{"name":"","range":"-20 °C až 0 °C","cmc":"1,2 °C"},{"name":"","range":"0 °C až 50 °C","cmc":"1,3 °C"},{"name":"","range":"50 °C až 100 °C","cmc":"1,4 °C"},{"name":"","range":"100 °C až 200 °C","cmc":"1,9 °C"},{"name":"","range":"200 °C až 300 °C","cmc":"2,8 °C"},{"name":"","range":"300 °C až 400 °C","cmc":"3,4 °C"},{"name":"","range":"400 °C až 500 °C","cmc":"3,6 °C"},{"name":"","range":"500 °C až 600 °C","cmc":"3,9 °C"},{"name":"","range":"600 °C až 800 °C","cmc":"5,0 °C"},{"name":"","range":"800 °C až 1000 °C","cmc":"6,1 °C"},{"name":"","range":"1000 °C až 1200 °C","cmc":"7,3 °C"}],"technique":"Porównanie z wzorcowym ciałem czarnym","technique_en":"Comparison with a reference black body","technique_zh":"与标准黑体比较","technique_cs":"Porovnání s etalonovým černým tělesem","techniques":["Porównanie z wzorcowym ciałem czarnym"],"techniques_en":["Comparison with a reference black body"],"techniques_zh":["与标准黑体比较"],"techniques_cs":["Porovnání s etalonovým černým tělesem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -20 °C do 0 °C CMC 1,2 °C\nod 0 °C do 50 °C CMC 1,3 °C\nod 50 °C do 100 °C CMC 1,4 °C\nod 100 °C do 200 °C CMC 1,9 °C\nod 200 °C do 300 °C CMC 2,8 °C\nod 300 °C do 400 °C CMC 3,4 °C\nod 400 °C do 500 °C CMC 3,6 °C\nod 500 °C do 600 °C CMC 3,9 °C\nod 600 °C do 800 °C CMC 5,0 °C\nod 800 °C do 1000 °C CMC 6,1 °C\nod 1000 °C do 1200 °C CMC 7,3 °C\nPorównanie z wzorcowym ciałem czarnym","reference":"KP-PB-53","norm_bases":["KP-PB-53"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Temperatura – termometry bezstykowe Wzorcowanie – temperatura Porównanie z wzorcowym ciałem czarnym od -20 °C do 0 °C CMC 1,2 °C od 0 °C do 50 °C CMC 1,3 °C od 50 °C do 100 °C CMC 1,4 °C od 100 °C do 200 °C CMC 1,9 °C od 200 °C do 300 °C CMC 2,8 °C od 300 °C do 400 °C CMC 3,4 °C od 400 °C do 500 °C CMC 3,6 °C od 500 °C do 600 °C CMC 3,9 °C od 600 °C do 800 °C CMC 5,0 °C od 800 °C do 1000 °C CMC 6,1 °C od 1000 °C do 1200 °C CMC 7,3 °C Teplota – bezkontaktní teploměry Kalibrace – teplota Porovnání s etalonovým černým tělesem -20 °C až 0 °C CMC 1,2 °C 0 °C až 50 °C CMC 1,3 °C 50 °C až 100 °C CMC 1,4 °C 100 °C až 200 °C CMC 1,9 °C 200 °C až 300 °C CMC 2,8 °C 300 °C až 400 °C CMC 3,4 °C 400 °C až 500 °C CMC 3,6 °C 500 °C až 600 °C CMC 3,9 °C 600 °C až 800 °C CMC 5,0 °C 800 °C až 1000 °C CMC 6,1 °C 1000 °C až 1200 °C CMC 7,3 °C KP-PB-53 Temperatura – termometry bezstykowe Wzorcowanie – temperatura Porownanie z wzorcowym cialem czarnym od -20 °C do 0 °C CMC 1,2 °C od 0 °C do 50 °C CMC 1,3 °C od 50 °C do 100 °C CMC 1,4 °C od 100 °C do 200 °C CMC 1,9 °C od 200 °C do 300 °C CMC 2,8 °C od 300 °C do 400 °C CMC 3,4 °C od 400 °C do 500 °C CMC 3,6 °C od 500 °C do 600 °C CMC 3,9 °C od 600 °C do 800 °C CMC 5,0 °C od 800 °C do 1000 °C CMC 6,1 °C od 1000 °C do 1200 °C CMC 7,3 °C Teplota – bezkontaktni teplomery Kalibrace – teplota Porovnani s etalonovym cernym telesem -20 °C az 0 °C CMC 1,2 °C 0 °C az 50 °C CMC 1,3 °C 50 °C az 100 °C CMC 1,4 °C 100 °C az 200 °C CMC 1,9 °C 200 °C az 300 °C CMC 2,8 °C 300 °C az 400 °C CMC 3,4 °C 400 °C az 500 °C CMC 3,6 °C 500 °C az 600 °C CMC 3,9 °C 600 °C az 800 °C CMC 5,0 °C 800 °C az 1000 °C CMC 6,1 °C 1000 °C az 1200 °C CMC 7,3 °C KP-PB-53","search_en":"Temperature – contactless thermometers Calibration – temperature Comparison with a reference black body Uherský Brod II CMC for the field of measured quantity: Temperature Comparison with a reference black body KP-PB-53","search_zh":"温度 – 非接触式温度计 校准 – 温度 与标准黑体比较 乌赫尔斯基布罗德 II 被测量领域的CMC：温度 与标准黑体比较 KP-PB-53","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von -20 °C bis 0 °C","cmc":"1,2 °C"},{"name":"","range":"von 0 °C bis 50 °C","cmc":"1,3 °C"},{"name":"","range":"von 50 °C bis 100 °C","cmc":"1,4 °C"},{"name":"","range":"von 100 °C bis 200 °C","cmc":"1,9 °C"},{"name":"","range":"von 200 °C bis 300 °C","cmc":"2,8 °C"},{"name":"","range":"von 300 °C bis 400 °C","cmc":"3,4 °C"},{"name":"","range":"von 400 °C bis 500 °C","cmc":"3,6 °C"},{"name":"","range":"von 500 °C bis 600 °C","cmc":"3,9 °C"},{"name":"","range":"von 600 °C bis 800 °C","cmc":"5,0 °C"},{"name":"","range":"von 800 °C bis 1000 °C","cmc":"6,1 °C"},{"name":"","range":"von 1000 °C bis 1200 °C","cmc":"7,3 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Temperatur – berührungslose Thermometer Kalibrierung – Temperatur Vergleich mit schwarzem Referenzstrahler Uherský Brod II CMC für den Messgrößenbereich: Temperatur Vergleich mit schwarzem Referenzstrahler KP-PB-53","technique_de":"Vergleich mit schwarzem Referenzstrahler","techniques_de":["Vergleich mit schwarzem Referenzstrahler"],"test_object_de":"Temperatur – berührungslose Thermometer"},{"_id":"ce0e2bad85c0f5af154cad59","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Kalibratory temperatury, wskaźniki temperatury","test_object_en":"Temperature calibrators, temperature indicators","test_object_zh":"温度校准器、温度指示器","test_object_cs":"Teplotní kalibrátory, indikátory teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"TC-J","range":"od -210 °C do 0 °C","cmc":"0,15 °C"},{"name":"TC-J","range":"od 0 °C do 1200 °C","cmc":"0,08 °C"},{"name":"TC-K","range":"od -270 °C do 0 °C","cmc":"0,18 °C"},{"name":"TC-K","range":"od 0 °C do 500 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"od 500 °C do 1372 °C","cmc":"0,12 °C"},{"name":"TC-T","range":"od -270 °C do 0 °C","cmc":"0,17 °C"},{"name":"TC-T","range":"od 0 °C do 400 °C","cmc":"0,05 °C"},{"name":"TC-R","range":"od -50 °C do 250 °C","cmc":"0,70 °C"},{"name":"TC-R","range":"od 250 °C do 1768 °C","cmc":"0,24 °C"},{"name":"TC-S","range":"od -50 °C do 250 °C","cmc":"0,64 °C"},{"name":"TC-S","range":"od 250 °C do 1768 °C","cmc":"0,24 °C"},{"name":"TC-B","range":"od 250 °C do 1820 °C","cmc":"0,41 °C"},{"name":"TC-N","range":"od -270 °C do 0 °C","cmc":"0,27 °C"},{"name":"TC-N","range":"od 0 °C do 1300 °C","cmc":"0,10 °C"},{"name":"TC-E","range":"od -270 °C do 0 °C","cmc":"0,12 °C"},{"name":"TC-E","range":"od 0 °C do 1000 °C","cmc":"0,07 °C"}],"parameters_en":[{"name":"TC-J","range":"-210 °C to 0 °C","cmc":"0,15 °C"},{"name":"TC-J","range":"0 °C to 1200 °C","cmc":"0,08 °C"},{"name":"TC-K","range":"-270 °C to 0 °C","cmc":"0,18 °C"},{"name":"TC-K","range":"0 °C to 500 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"500 °C to 1372 °C","cmc":"0,12 °C"},{"name":"TC-T","range":"-270 °C to 0 °C","cmc":"0,17 °C"},{"name":"TC-T","range":"0 °C to 400 °C","cmc":"0,05 °C"},{"name":"TC-R","range":"-50 °C to 250 °C","cmc":"0,70 °C"},{"name":"TC-R","range":"250 °C to 1768 °C","cmc":"0,24 °C"},{"name":"TC-S","range":"-50 °C to 250 °C","cmc":"0,64 °C"},{"name":"TC-S","range":"250 °C to 1768 °C","cmc":"0,24 °C"},{"name":"TC-B","range":"250 °C to 1820 °C","cmc":"0,41 °C"},{"name":"TC-N","range":"-270 °C to 0 °C","cmc":"0,27 °C"},{"name":"TC-N","range":"0 °C to 1300 °C","cmc":"0,10 °C"},{"name":"TC-E","range":"-270 °C to 0 °C","cmc":"0,12 °C"},{"name":"TC-E","range":"0 °C to 1000 °C","cmc":"0,07 °C"}],"parameters_zh":[{"name":"TC-J","range":"-210 °C 至 0 °C","cmc":"0,15 °C"},{"name":"TC-J","range":"0 °C 至 1200 °C","cmc":"0,08 °C"},{"name":"TC-K","range":"-270 °C 至 0 °C","cmc":"0,18 °C"},{"name":"TC-K","range":"0 °C 至 500 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"500 °C 至 1372 °C","cmc":"0,12 °C"},{"name":"TC-T","range":"-270 °C 至 0 °C","cmc":"0,17 °C"},{"name":"TC-T","range":"0 °C 至 400 °C","cmc":"0,05 °C"},{"name":"TC-R","range":"-50 °C 至 250 °C","cmc":"0,70 °C"},{"name":"TC-R","range":"250 °C 至 1768 °C","cmc":"0,24 °C"},{"name":"TC-S","range":"-50 °C 至 250 °C","cmc":"0,64 °C"},{"name":"TC-S","range":"250 °C 至 1768 °C","cmc":"0,24 °C"},{"name":"TC-B","range":"250 °C 至 1820 °C","cmc":"0,41 °C"},{"name":"TC-N","range":"-270 °C 至 0 °C","cmc":"0,27 °C"},{"name":"TC-N","range":"0 °C 至 1300 °C","cmc":"0,10 °C"},{"name":"TC-E","range":"-270 °C 至 0 °C","cmc":"0,12 °C"},{"name":"TC-E","range":"0 °C 至 1000 °C","cmc":"0,07 °C"}],"parameters_cs":[{"name":"TC-J","range":"-210 °C až 0 °C","cmc":"0,15 °C"},{"name":"TC-J","range":"0 °C až 1200 °C","cmc":"0,08 °C"},{"name":"TC-K","range":"-270 °C až 0 °C","cmc":"0,18 °C"},{"name":"TC-K","range":"0 °C až 500 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"500 °C až 1372 °C","cmc":"0,12 °C"},{"name":"TC-T","range":"-270 °C až 0 °C","cmc":"0,17 °C"},{"name":"TC-T","range":"0 °C až 400 °C","cmc":"0,05 °C"},{"name":"TC-R","range":"-50 °C až 250 °C","cmc":"0,70 °C"},{"name":"TC-R","range":"250 °C až 1768 °C","cmc":"0,24 °C"},{"name":"TC-S","range":"-50 °C až 250 °C","cmc":"0,64 °C"},{"name":"TC-S","range":"250 °C až 1768 °C","cmc":"0,24 °C"},{"name":"TC-B","range":"250 °C až 1820 °C","cmc":"0,41 °C"},{"name":"TC-N","range":"-270 °C až 0 °C","cmc":"0,27 °C"},{"name":"TC-N","range":"0 °C až 1300 °C","cmc":"0,10 °C"},{"name":"TC-E","range":"-270 °C až 0 °C","cmc":"0,12 °C"},{"name":"TC-E","range":"0 °C až 1000 °C","cmc":"0,07 °C"}],"technique":"Bezpośrednie generowanie równoważnego napięcia stałego dla termopar (TC) – bez kompensacji zimnego końca","technique_en":"Direct generation of equivalent DC voltage for TC – without cold junction compensation","technique_zh":"直接产生热电偶（TC）等效直流电压 – 无冷端补偿","technique_cs":"Přímé generování ekvivalentního stejnosměrného napětí pro TC – bez kompenzace studeného konce","techniques":["Bezpośrednie generowanie równoważnego napięcia stałego dla termopar (TC) – bez kompensacji zimnego końca"],"techniques_en":["Direct generation of equivalent DC voltage for TC – without cold junction compensation"],"techniques_zh":["直接产生热电偶（TC）等效直流电压 – 无冷端补偿"],"techniques_cs":["Přímé generování ekvivalentního stejnosměrného napětí pro TC – bez kompenzace studeného konce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nTC-J od -210 °C do 0 °C CMC 0,15 °C\nTC-J od 0 °C do 1200 °C CMC 0,08 °C\nTC-K od -270 °C do 0 °C CMC 0,18 °C\nTC-K od 0 °C do 500 °C CMC 0,09 °C\nTC-K od 500 °C do 1372 °C CMC 0,12 °C\nTC-T od -270 °C do 0 °C CMC 0,17 °C\nTC-T od 0 °C do 400 °C CMC 0,05 °C\nTC-R od -50 °C do 250 °C CMC 0,70 °C\nTC-R od 250 °C do 1768 °C CMC 0,24 °C\nTC-S od -50 °C do 250 °C CMC 0,64 °C\nTC-S od 250 °C do 1768 °C CMC 0,24 °C\nTC-B od 250 °C do 1820 °C CMC 0,41 °C\nTC-N od -270 °C do 0 °C CMC 0,27 °C\nTC-N od 0 °C do 1300 °C CMC 0,10 °C\nTC-E od -270 °C do 0 °C CMC 0,12 °C\nTC-E od 0 °C do 1000 °C CMC 0,07 °C\nBezpośrednie generowanie równoważnego napięcia stałego dla termopar (TC) – bez kompensacji zimnego końca","reference":"KP-PB-122","norm_bases":["KP-PB-122"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kalibratory temperatury, wskaźniki temperatury Wzorcowanie – temperatura Bezpośrednie generowanie równoważnego napięcia stałego dla termopar (TC) – bez kompensacji zimnego końca TC-J od -210 °C do 0 °C CMC 0,15 °C TC-J od 0 °C do 1200 °C CMC 0,08 °C TC-K od -270 °C do 0 °C CMC 0,18 °C TC-K od 0 °C do 500 °C CMC 0,09 °C TC-K od 500 °C do 1372 °C CMC 0,12 °C TC-T od -270 °C do 0 °C CMC 0,17 °C TC-T od 0 °C do 400 °C CMC 0,05 °C TC-R od -50 °C do 250 °C CMC 0,70 °C TC-R od 250 °C do 1768 °C CMC 0,24 °C TC-S od -50 °C do 250 °C CMC 0,64 °C TC-S od 250 °C do 1768 °C CMC 0,24 °C TC-B od 250 °C do 1820 °C CMC 0,41 °C TC-N od -270 °C do 0 °C CMC 0,27 °C TC-N od 0 °C do 1300 °C CMC 0,10 °C TC-E od -270 °C do 0 °C CMC 0,12 °C TC-E od 0 °C do 1000 °C CMC 0,07 °C Teplotní kalibrátory, indikátory teploty Kalibrace – teplota Přímé generování ekvivalentního stejnosměrného napětí pro TC – bez kompenzace studeného konce TC-J -210 °C až 0 °C CMC 0,15 °C TC-J 0 °C až 1200 °C CMC 0,08 °C TC-K -270 °C až 0 °C CMC 0,18 °C TC-K 0 °C až 500 °C CMC 0,09 °C TC-K 500 °C až 1372 °C CMC 0,12 °C TC-T -270 °C až 0 °C CMC 0,17 °C TC-T 0 °C až 400 °C CMC 0,05 °C TC-R -50 °C až 250 °C CMC 0,70 °C TC-R 250 °C až 1768 °C CMC 0,24 °C TC-S -50 °C až 250 °C CMC 0,64 °C TC-S 250 °C až 1768 °C CMC 0,24 °C TC-B 250 °C až 1820 °C CMC 0,41 °C TC-N -270 °C až 0 °C CMC 0,27 °C TC-N 0 °C až 1300 °C CMC 0,10 °C TC-E -270 °C až 0 °C CMC 0,12 °C TC-E 0 °C až 1000 °C CMC 0,07 °C KP-PB-122 Kalibratory temperatury, wskazniki temperatury Wzorcowanie – temperatura Bezposrednie generowanie rownowaznego napiecia stalego dla termopar (TC) – bez kompensacji zimnego konca TC-J od -210 °C do 0 °C CMC 0,15 °C TC-J od 0 °C do 1200 °C CMC 0,08 °C TC-K od -270 °C do 0 °C CMC 0,18 °C TC-K od 0 °C do 500 °C CMC 0,09 °C TC-K od 500 °C do 1372 °C CMC 0,12 °C TC-T od -270 °C do 0 °C CMC 0,17 °C TC-T od 0 °C do 400 °C CMC 0,05 °C TC-R od -50 °C do 250 °C CMC 0,70 °C TC-R od 250 °C do 1768 °C CMC 0,24 °C TC-S od -50 °C do 250 °C CMC 0,64 °C TC-S od 250 °C do 1768 °C CMC 0,24 °C TC-B od 250 °C do 1820 °C CMC 0,41 °C TC-N od -270 °C do 0 °C CMC 0,27 °C TC-N od 0 °C do 1300 °C CMC 0,10 °C TC-E od -270 °C do 0 °C CMC 0,12 °C TC-E od 0 °C do 1000 °C CMC 0,07 °C Teplotni kalibratory, indikatory teploty Kalibrace – teplota Prime generovani ekvivalentniho stejnosmerneho napeti pro TC – bez kompenzace studeneho konce TC-J -210 °C az 0 °C CMC 0,15 °C TC-J 0 °C az 1200 °C CMC 0,08 °C TC-K -270 °C az 0 °C CMC 0,18 °C TC-K 0 °C az 500 °C CMC 0,09 °C TC-K 500 °C az 1372 °C CMC 0,12 °C TC-T -270 °C az 0 °C CMC 0,17 °C TC-T 0 °C az 400 °C CMC 0,05 °C TC-R -50 °C az 250 °C CMC 0,70 °C TC-R 250 °C az 1768 °C CMC 0,24 °C TC-S -50 °C az 250 °C CMC 0,64 °C TC-S 250 °C az 1768 °C CMC 0,24 °C TC-B 250 °C az 1820 °C CMC 0,41 °C TC-N -270 °C az 0 °C CMC 0,27 °C TC-N 0 °C az 1300 °C CMC 0,10 °C TC-E -270 °C az 0 °C CMC 0,12 °C TC-E 0 °C az 1000 °C CMC 0,07 °C KP-PB-122","search_en":"Temperature calibrators, temperature indicators Calibration – temperature Direct generation of equivalent DC voltage for TC – without cold junction compensation Uherský Brod II CMC for the field of measured quantity: Temperature Direct generation of equivalent DC voltage for TC – without cold junction compensation TC-J TC-J TC-K TC-K TC-K TC-T TC-T TC-R TC-R TC-S TC-S TC-B TC-N TC-N TC-E TC-E KP-PB-122","search_zh":"温度校准器、温度指示器 校准 – 温度 直接产生热电偶（TC）等效直流电压 – 无冷端补偿 乌赫尔斯基布罗德 II 被测量领域的CMC：温度 直接产生热电偶（TC）等效直流电压 – 无冷端补偿 TC-J TC-J TC-K TC-K TC-K TC-T TC-T TC-R TC-R TC-S TC-S TC-B TC-N TC-N TC-E TC-E KP-PB-122","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"TC-J","range":"von -210 °C bis 0 °C","cmc":"0,15 °C"},{"name":"TC-J","range":"von 0 °C bis 1200 °C","cmc":"0,08 °C"},{"name":"TC-K","range":"von -270 °C bis 0 °C","cmc":"0,18 °C"},{"name":"TC-K","range":"von 0 °C bis 500 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"von 500 °C bis 1372 °C","cmc":"0,12 °C"},{"name":"TC-T","range":"von -270 °C bis 0 °C","cmc":"0,17 °C"},{"name":"TC-T","range":"von 0 °C bis 400 °C","cmc":"0,05 °C"},{"name":"TC-R","range":"von -50 °C bis 250 °C","cmc":"0,70 °C"},{"name":"TC-R","range":"von 250 °C bis 1768 °C","cmc":"0,24 °C"},{"name":"TC-S","range":"von -50 °C bis 250 °C","cmc":"0,64 °C"},{"name":"TC-S","range":"von 250 °C bis 1768 °C","cmc":"0,24 °C"},{"name":"TC-B","range":"von 250 °C bis 1820 °C","cmc":"0,41 °C"},{"name":"TC-N","range":"von -270 °C bis 0 °C","cmc":"0,27 °C"},{"name":"TC-N","range":"von 0 °C bis 1300 °C","cmc":"0,10 °C"},{"name":"TC-E","range":"von -270 °C bis 0 °C","cmc":"0,12 °C"},{"name":"TC-E","range":"von 0 °C bis 1000 °C","cmc":"0,07 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Temperaturkalibratoren, Temperaturanzeiger Kalibrierung – Temperatur Direkte Erzeugung der äquivalenten Gleichspannung für Thermoelemente (TC) – ohne Vergleichsstellenkompensation Uherský Brod II CMC für den Messgrößenbereich: Temperatur Direkte Erzeugung der äquivalenten Gleichspannung für Thermoelemente (TC) – ohne Vergleichsstellenkompensation TC-J TC-J TC-K TC-K TC-K TC-T TC-T TC-R TC-R TC-S TC-S TC-B TC-N TC-N TC-E TC-E KP-PB-122","technique_de":"Direkte Erzeugung der äquivalenten Gleichspannung für Thermoelemente (TC) – ohne Vergleichsstellenkompensation","techniques_de":["Direkte Erzeugung der äquivalenten Gleichspannung für Thermoelemente (TC) – ohne Vergleichsstellenkompensation"],"test_object_de":"Temperaturkalibratoren, Temperaturanzeiger"},{"_id":"6d3b5b61851a884b1acbb164","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Kalibratory temperatury, wskaźniki temperatury","test_object_en":"Temperature calibrators, temperature indicators","test_object_zh":"温度校准器、温度指示器","test_object_cs":"Teplotní kalibrátory, indikátory teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"TC-J","range":"od -210 °C do 0 °C","cmc":"0,08 °C"},{"name":"TC-J","range":"od 0 °C do 1200 °C","cmc":"0,07 °C"},{"name":"TC-K","range":"od -270 °C do 0 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"od 0 °C do 500 °C","cmc":"0,06 °C"},{"name":"TC-K","range":"od 500 °C do 1372 °C","cmc":"0,07 °C"},{"name":"TC-T","range":"od -270 °C do 0 °C","cmc":"0,09 °C"},{"name":"TC-T","range":"od 0 °C do 400 °C","cmc":"0,03 °C"},{"name":"TC-R","range":"od -50 °C do 250 °C","cmc":"0,32 °C"},{"name":"TC-R","range":"od 250 °C do 1064 °C","cmc":"0,09 °C"},{"name":"TC-R","range":"od 1064 °C do 1768 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"od -50 °C do 250 °C","cmc":"0,29 °C"},{"name":"TC-S","range":"od 250 °C do 1064 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"od 1064 °C do 1768 °C","cmc":"0,12 °C"},{"name":"TC-B","range":"od 250 °C do 700 °C","cmc":"0,18 °C"},{"name":"TC-B","range":"od 700 °C do 1820 °C","cmc":"0,11 °C"},{"name":"TC-N","range":"od -270 °C do 0 °C","cmc":"0,12 °C"},{"name":"TC-N","range":"od 0 °C do 600 °C","cmc":"0,04 °C"},{"name":"TC-N","range":"od 600 °C do 1300 °C","cmc":"0,04 °C"},{"name":"TC-E","range":"od -270 °C do 0 °C","cmc":"0,05 °C"},{"name":"TC-E","range":"od 0 °C do 1000 °C","cmc":"0,03 °C"}],"parameters_en":[{"name":"TC-J","range":"-210 °C to 0 °C","cmc":"0,08 °C"},{"name":"TC-J","range":"0 °C to 1200 °C","cmc":"0,07 °C"},{"name":"TC-K","range":"-270 °C to 0 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"0 °C to 500 °C","cmc":"0,06 °C"},{"name":"TC-K","range":"500 °C to 1372 °C","cmc":"0,07 °C"},{"name":"TC-T","range":"-270 °C to 0 °C","cmc":"0,09 °C"},{"name":"TC-T","range":"0 °C to 400 °C","cmc":"0,03 °C"},{"name":"TC-R","range":"-50 °C to 250 °C","cmc":"0,32 °C"},{"name":"TC-R","range":"250 °C to 1064 °C","cmc":"0,09 °C"},{"name":"TC-R","range":"1064 °C to 1768 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"-50 °C to 250 °C","cmc":"0,29 °C"},{"name":"TC-S","range":"250 °C to 1064 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"1064 °C to 1768 °C","cmc":"0,12 °C"},{"name":"TC-B","range":"250 °C to 700 °C","cmc":"0,18 °C"},{"name":"TC-B","range":"700 °C to 1820 °C","cmc":"0,11 °C"},{"name":"TC-N","range":"-270 °C to 0 °C","cmc":"0,12 °C"},{"name":"TC-N","range":"0 °C to 600 °C","cmc":"0,04 °C"},{"name":"TC-N","range":"600 °C to 1300 °C","cmc":"0,04 °C"},{"name":"TC-E","range":"-270 °C to 0 °C","cmc":"0,05 °C"},{"name":"TC-E","range":"0 °C to 1000 °C","cmc":"0,03 °C"}],"parameters_zh":[{"name":"TC-J","range":"-210 °C 至 0 °C","cmc":"0,08 °C"},{"name":"TC-J","range":"0 °C 至 1200 °C","cmc":"0,07 °C"},{"name":"TC-K","range":"-270 °C 至 0 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"0 °C 至 500 °C","cmc":"0,06 °C"},{"name":"TC-K","range":"500 °C 至 1372 °C","cmc":"0,07 °C"},{"name":"TC-T","range":"-270 °C 至 0 °C","cmc":"0,09 °C"},{"name":"TC-T","range":"0 °C 至 400 °C","cmc":"0,03 °C"},{"name":"TC-R","range":"-50 °C 至 250 °C","cmc":"0,32 °C"},{"name":"TC-R","range":"250 °C 至 1064 °C","cmc":"0,09 °C"},{"name":"TC-R","range":"1064 °C 至 1768 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"-50 °C 至 250 °C","cmc":"0,29 °C"},{"name":"TC-S","range":"250 °C 至 1064 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"1064 °C 至 1768 °C","cmc":"0,12 °C"},{"name":"TC-B","range":"250 °C 至 700 °C","cmc":"0,18 °C"},{"name":"TC-B","range":"700 °C 至 1820 °C","cmc":"0,11 °C"},{"name":"TC-N","range":"-270 °C 至 0 °C","cmc":"0,12 °C"},{"name":"TC-N","range":"0 °C 至 600 °C","cmc":"0,04 °C"},{"name":"TC-N","range":"600 °C 至 1300 °C","cmc":"0,04 °C"},{"name":"TC-E","range":"-270 °C 至 0 °C","cmc":"0,05 °C"},{"name":"TC-E","range":"0 °C 至 1000 °C","cmc":"0,03 °C"}],"parameters_cs":[{"name":"TC-J","range":"-210 °C až 0 °C","cmc":"0,08 °C"},{"name":"TC-J","range":"0 °C až 1200 °C","cmc":"0,07 °C"},{"name":"TC-K","range":"-270 °C až 0 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"0 °C až 500 °C","cmc":"0,06 °C"},{"name":"TC-K","range":"500 °C až 1372 °C","cmc":"0,07 °C"},{"name":"TC-T","range":"-270 °C až 0 °C","cmc":"0,09 °C"},{"name":"TC-T","range":"0 °C až 400 °C","cmc":"0,03 °C"},{"name":"TC-R","range":"-50 °C až 250 °C","cmc":"0,32 °C"},{"name":"TC-R","range":"250 °C až 1064 °C","cmc":"0,09 °C"},{"name":"TC-R","range":"1064 °C až 1768 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"-50 °C až 250 °C","cmc":"0,29 °C"},{"name":"TC-S","range":"250 °C až 1064 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"1064 °C až 1768 °C","cmc":"0,12 °C"},{"name":"TC-B","range":"250 °C až 700 °C","cmc":"0,18 °C"},{"name":"TC-B","range":"700 °C až 1820 °C","cmc":"0,11 °C"},{"name":"TC-N","range":"-270 °C až 0 °C","cmc":"0,12 °C"},{"name":"TC-N","range":"0 °C až 600 °C","cmc":"0,04 °C"},{"name":"TC-N","range":"600 °C až 1300 °C","cmc":"0,04 °C"},{"name":"TC-E","range":"-270 °C až 0 °C","cmc":"0,05 °C"},{"name":"TC-E","range":"0 °C až 1000 °C","cmc":"0,03 °C"}],"technique":"Pomiar bezpośredni równoważnego napięcia stałego dla termopar (TC) – bez kompensacji zimnego końca","technique_en":"Direct measurement of equivalent DC voltage for TC – without cold junction compensation","technique_zh":"直接测量热电偶（TC）等效直流电压 – 无冷端补偿","technique_cs":"Přímé měření ekvivalentního stejnosměrného napětí pro TC – bez kompenzace studeného konce","techniques":["Pomiar bezpośredni równoważnego napięcia stałego dla termopar (TC) – bez kompensacji zimnego końca"],"techniques_en":["Direct measurement of equivalent DC voltage for TC – without cold junction compensation"],"techniques_zh":["直接测量热电偶（TC）等效直流电压 – 无冷端补偿"],"techniques_cs":["Přímé měření ekvivalentního stejnosměrného napětí pro TC – bez kompenzace studeného konce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nTC-J od -210 °C do 0 °C CMC 0,08 °C\nTC-J od 0 °C do 1200 °C CMC 0,07 °C\nTC-K od -270 °C do 0 °C CMC 0,09 °C\nTC-K od 0 °C do 500 °C CMC 0,06 °C\nTC-K od 500 °C do 1372 °C CMC 0,07 °C\nTC-T od -270 °C do 0 °C CMC 0,09 °C\nTC-T od 0 °C do 400 °C CMC 0,03 °C\nTC-R od -50 °C do 250 °C CMC 0,32 °C\nTC-R od 250 °C do 1064 °C CMC 0,09 °C\nTC-R od 1064 °C do 1768 °C CMC 0,10 °C\nTC-S od -50 °C do 250 °C CMC 0,29 °C\nTC-S od 250 °C do 1064 °C CMC 0,10 °C\nTC-S od 1064 °C do 1768 °C CMC 0,12 °C\nTC-B od 250 °C do 700 °C CMC 0,18 °C\nTC-B od 700 °C do 1820 °C CMC 0,11 °C\nTC-N od -270 °C do 0 °C CMC 0,12 °C\nTC-N od 0 °C do 600 °C CMC 0,04 °C\nTC-N od 600 °C do 1300 °C CMC 0,04 °C\nTC-E od -270 °C do 0 °C CMC 0,05 °C\nTC-E od 0 °C do 1000 °C CMC 0,03 °C\nPomiar bezpośredni równoważnego napięcia stałego dla termopar (TC) – bez kompensacji zimnego końca","reference":"KP-PB-122","norm_bases":["KP-PB-122"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kalibratory temperatury, wskaźniki temperatury Wzorcowanie – temperatura Pomiar bezpośredni równoważnego napięcia stałego dla termopar (TC) – bez kompensacji zimnego końca TC-J od -210 °C do 0 °C CMC 0,08 °C TC-J od 0 °C do 1200 °C CMC 0,07 °C TC-K od -270 °C do 0 °C CMC 0,09 °C TC-K od 0 °C do 500 °C CMC 0,06 °C TC-K od 500 °C do 1372 °C CMC 0,07 °C TC-T od -270 °C do 0 °C CMC 0,09 °C TC-T od 0 °C do 400 °C CMC 0,03 °C TC-R od -50 °C do 250 °C CMC 0,32 °C TC-R od 250 °C do 1064 °C CMC 0,09 °C TC-R od 1064 °C do 1768 °C CMC 0,10 °C TC-S od -50 °C do 250 °C CMC 0,29 °C TC-S od 250 °C do 1064 °C CMC 0,10 °C TC-S od 1064 °C do 1768 °C CMC 0,12 °C TC-B od 250 °C do 700 °C CMC 0,18 °C TC-B od 700 °C do 1820 °C CMC 0,11 °C TC-N od -270 °C do 0 °C CMC 0,12 °C TC-N od 0 °C do 600 °C CMC 0,04 °C TC-N od 600 °C do 1300 °C CMC 0,04 °C TC-E od -270 °C do 0 °C CMC 0,05 °C TC-E od 0 °C do 1000 °C CMC 0,03 °C Teplotní kalibrátory, indikátory teploty Kalibrace – teplota Přímé měření ekvivalentního stejnosměrného napětí pro TC – bez kompenzace studeného konce TC-J -210 °C až 0 °C CMC 0,08 °C TC-J 0 °C až 1200 °C CMC 0,07 °C TC-K -270 °C až 0 °C CMC 0,09 °C TC-K 0 °C až 500 °C CMC 0,06 °C TC-K 500 °C až 1372 °C CMC 0,07 °C TC-T -270 °C až 0 °C CMC 0,09 °C TC-T 0 °C až 400 °C CMC 0,03 °C TC-R -50 °C až 250 °C CMC 0,32 °C TC-R 250 °C až 1064 °C CMC 0,09 °C TC-R 1064 °C až 1768 °C CMC 0,10 °C TC-S -50 °C až 250 °C CMC 0,29 °C TC-S 250 °C až 1064 °C CMC 0,10 °C TC-S 1064 °C až 1768 °C CMC 0,12 °C TC-B 250 °C až 700 °C CMC 0,18 °C TC-B 700 °C až 1820 °C CMC 0,11 °C TC-N -270 °C až 0 °C CMC 0,12 °C TC-N 0 °C až 600 °C CMC 0,04 °C TC-N 600 °C až 1300 °C CMC 0,04 °C TC-E -270 °C až 0 °C CMC 0,05 °C TC-E 0 °C až 1000 °C CMC 0,03 °C KP-PB-122 Kalibratory temperatury, wskazniki temperatury Wzorcowanie – temperatura Pomiar bezposredni rownowaznego napiecia stalego dla termopar (TC) – bez kompensacji zimnego konca TC-J od -210 °C do 0 °C CMC 0,08 °C TC-J od 0 °C do 1200 °C CMC 0,07 °C TC-K od -270 °C do 0 °C CMC 0,09 °C TC-K od 0 °C do 500 °C CMC 0,06 °C TC-K od 500 °C do 1372 °C CMC 0,07 °C TC-T od -270 °C do 0 °C CMC 0,09 °C TC-T od 0 °C do 400 °C CMC 0,03 °C TC-R od -50 °C do 250 °C CMC 0,32 °C TC-R od 250 °C do 1064 °C CMC 0,09 °C TC-R od 1064 °C do 1768 °C CMC 0,10 °C TC-S od -50 °C do 250 °C CMC 0,29 °C TC-S od 250 °C do 1064 °C CMC 0,10 °C TC-S od 1064 °C do 1768 °C CMC 0,12 °C TC-B od 250 °C do 700 °C CMC 0,18 °C TC-B od 700 °C do 1820 °C CMC 0,11 °C TC-N od -270 °C do 0 °C CMC 0,12 °C TC-N od 0 °C do 600 °C CMC 0,04 °C TC-N od 600 °C do 1300 °C CMC 0,04 °C TC-E od -270 °C do 0 °C CMC 0,05 °C TC-E od 0 °C do 1000 °C CMC 0,03 °C Teplotni kalibratory, indikatory teploty Kalibrace – teplota Prime mereni ekvivalentniho stejnosmerneho napeti pro TC – bez kompenzace studeneho konce TC-J -210 °C az 0 °C CMC 0,08 °C TC-J 0 °C az 1200 °C CMC 0,07 °C TC-K -270 °C az 0 °C CMC 0,09 °C TC-K 0 °C az 500 °C CMC 0,06 °C TC-K 500 °C az 1372 °C CMC 0,07 °C TC-T -270 °C az 0 °C CMC 0,09 °C TC-T 0 °C az 400 °C CMC 0,03 °C TC-R -50 °C az 250 °C CMC 0,32 °C TC-R 250 °C az 1064 °C CMC 0,09 °C TC-R 1064 °C az 1768 °C CMC 0,10 °C TC-S -50 °C az 250 °C CMC 0,29 °C TC-S 250 °C az 1064 °C CMC 0,10 °C TC-S 1064 °C az 1768 °C CMC 0,12 °C TC-B 250 °C az 700 °C CMC 0,18 °C TC-B 700 °C az 1820 °C CMC 0,11 °C TC-N -270 °C az 0 °C CMC 0,12 °C TC-N 0 °C az 600 °C CMC 0,04 °C TC-N 600 °C az 1300 °C CMC 0,04 °C TC-E -270 °C az 0 °C CMC 0,05 °C TC-E 0 °C az 1000 °C CMC 0,03 °C KP-PB-122","search_en":"Temperature calibrators, temperature indicators Calibration – temperature Direct measurement of equivalent DC voltage for TC – without cold junction compensation Uherský Brod II CMC for the field of measured quantity: Temperature Direct measurement of equivalent DC voltage for TC – without cold junction compensation TC-J TC-J TC-K TC-K TC-K TC-T TC-T TC-R TC-R TC-R TC-S TC-S TC-S TC-B TC-B TC-N TC-N TC-N TC-E TC-E KP-PB-122","search_zh":"温度校准器、温度指示器 校准 – 温度 直接测量热电偶（TC）等效直流电压 – 无冷端补偿 乌赫尔斯基布罗德 II 被测量领域的CMC：温度 直接测量热电偶（TC）等效直流电压 – 无冷端补偿 TC-J TC-J TC-K TC-K TC-K TC-T TC-T TC-R TC-R TC-R TC-S TC-S TC-S TC-B TC-B TC-N TC-N TC-N TC-E TC-E KP-PB-122","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"TC-J","range":"von -210 °C bis 0 °C","cmc":"0,08 °C"},{"name":"TC-J","range":"von 0 °C bis 1200 °C","cmc":"0,07 °C"},{"name":"TC-K","range":"von -270 °C bis 0 °C","cmc":"0,09 °C"},{"name":"TC-K","range":"von 0 °C bis 500 °C","cmc":"0,06 °C"},{"name":"TC-K","range":"von 500 °C bis 1372 °C","cmc":"0,07 °C"},{"name":"TC-T","range":"von -270 °C bis 0 °C","cmc":"0,09 °C"},{"name":"TC-T","range":"von 0 °C bis 400 °C","cmc":"0,03 °C"},{"name":"TC-R","range":"von -50 °C bis 250 °C","cmc":"0,32 °C"},{"name":"TC-R","range":"von 250 °C bis 1064 °C","cmc":"0,09 °C"},{"name":"TC-R","range":"von 1064 °C bis 1768 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"von -50 °C bis 250 °C","cmc":"0,29 °C"},{"name":"TC-S","range":"von 250 °C bis 1064 °C","cmc":"0,10 °C"},{"name":"TC-S","range":"von 1064 °C bis 1768 °C","cmc":"0,12 °C"},{"name":"TC-B","range":"von 250 °C bis 700 °C","cmc":"0,18 °C"},{"name":"TC-B","range":"von 700 °C bis 1820 °C","cmc":"0,11 °C"},{"name":"TC-N","range":"von -270 °C bis 0 °C","cmc":"0,12 °C"},{"name":"TC-N","range":"von 0 °C bis 600 °C","cmc":"0,04 °C"},{"name":"TC-N","range":"von 600 °C bis 1300 °C","cmc":"0,04 °C"},{"name":"TC-E","range":"von -270 °C bis 0 °C","cmc":"0,05 °C"},{"name":"TC-E","range":"von 0 °C bis 1000 °C","cmc":"0,03 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Temperaturkalibratoren, Temperaturanzeiger Kalibrierung – Temperatur Direkte Messung der äquivalenten Gleichspannung für Thermoelemente (TC) – ohne Vergleichsstellenkompensation Uherský Brod II CMC für den Messgrößenbereich: Temperatur Direkte Messung der äquivalenten Gleichspannung für Thermoelemente (TC) – ohne Vergleichsstellenkompensation TC-J TC-J TC-K TC-K TC-K TC-T TC-T TC-R TC-R TC-R TC-S TC-S TC-S TC-B TC-B TC-N TC-N TC-N TC-E TC-E KP-PB-122","technique_de":"Direkte Messung der äquivalenten Gleichspannung für Thermoelemente (TC) – ohne Vergleichsstellenkompensation","techniques_de":["Direkte Messung der äquivalenten Gleichspannung für Thermoelemente (TC) – ohne Vergleichsstellenkompensation"],"test_object_de":"Temperaturkalibratoren, Temperaturanzeiger"},{"_id":"7c027ee22b8efb4c9b522274","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Kalibratory temperatury, wskaźniki temperatury","test_object_en":"Temperature calibrators, temperature indicators","test_object_zh":"温度校准器、温度指示器","test_object_cs":"Teplotní kalibrátory, indikátory teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Pt 100 (3850)","range":"-100 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"0 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"30 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"60 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"100 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"200 °C","cmc":"0,05 °C"},{"name":"Pt 100 (3850)","range":"400 °C","cmc":"0,07 °C"},{"name":"Pt 100 (3850)","range":"800 °C","cmc":"0,13 °C"},{"name":"Pt 100 (3850)","range":"od -200 °C do 0 °C","cmc":"0,15 °C"},{"name":"Pt 100 (3850)","range":"od 0 °C do 800 °C","cmc":"0,43 °C"},{"name":"Pt 500 (3850)","range":"od -200 °C do 260 °C","cmc":"0,12 °C"},{"name":"Pt 500 (3850)","range":"od 260 °C do 800 °C","cmc":"0,45 °C"},{"name":"Pt 1000 (3850)","range":"od -200 °C do 0 °C","cmc":"0,05 °C"},{"name":"Pt 1000 (3850)","range":"od 0 °C do 800 °C","cmc":"0,45 °C"},{"name":"Ni 100 (6180)","range":"od -60 °C do 0 °C","cmc":"0,12 °C"},{"name":"Ni 100 (6180)","range":"0 °C","cmc":"0,02 °C"},{"name":"Ni 100 (6180)","range":"od 0 °C do 250 °C","cmc":"0,21 °C"},{"name":"Ni 120 (6720)","range":"od -80 °C do 0 °C","cmc":"0,08 °C"},{"name":"Ni 120 (6720)","range":"od 0 °C do 260 °C","cmc":"0,11 °C"},{"name":"Ni 1000 (6180)","range":"od -50 °C do 0 °C","cmc":"0,03 °C"},{"name":"Ni 1000 (6180)","range":"od 0 °C do 200 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"Pt 100 (3850)","range":"-100 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"0 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"30 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"60 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"100 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"200 °C","cmc":"0,05 °C"},{"name":"Pt 100 (3850)","range":"400 °C","cmc":"0,07 °C"},{"name":"Pt 100 (3850)","range":"800 °C","cmc":"0,13 °C"},{"name":"Pt 100 (3850)","range":"-200 °C to 0 °C","cmc":"0,15 °C"},{"name":"Pt 100 (3850)","range":"0 °C to 800 °C","cmc":"0,43 °C"},{"name":"Pt 500 (3850)","range":"-200 °C to 260 °C","cmc":"0,12 °C"},{"name":"Pt 500 (3850)","range":"260 °C to 800 °C","cmc":"0,45 °C"},{"name":"Pt 1000 (3850)","range":"-200 °C to 0 °C","cmc":"0,05 °C"},{"name":"Pt 1000 (3850)","range":"0 °C to 800 °C","cmc":"0,45 °C"},{"name":"Ni 100 (6180)","range":"-60 °C to 0 °C","cmc":"0,12 °C"},{"name":"Ni 100 (6180)","range":"0 °C","cmc":"0,02 °C"},{"name":"Ni 100 (6180)","range":"0 °C to 250 °C","cmc":"0,21 °C"},{"name":"Ni 120 (6720)","range":"-80 °C to 0 °C","cmc":"0,08 °C"},{"name":"Ni 120 (6720)","range":"0 °C to 260 °C","cmc":"0,11 °C"},{"name":"Ni 1000 (6180)","range":"-50 °C to 0 °C","cmc":"0,03 °C"},{"name":"Ni 1000 (6180)","range":"0 °C to 200 °C","cmc":"0,15 °C"}],"parameters_zh":[{"name":"Pt 100 (3850)","range":"-100 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"0 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"30 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"60 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"100 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"200 °C","cmc":"0,05 °C"},{"name":"Pt 100 (3850)","range":"400 °C","cmc":"0,07 °C"},{"name":"Pt 100 (3850)","range":"800 °C","cmc":"0,13 °C"},{"name":"Pt 100 (3850)","range":"-200 °C 至 0 °C","cmc":"0,15 °C"},{"name":"Pt 100 (3850)","range":"0 °C 至 800 °C","cmc":"0,43 °C"},{"name":"Pt 500 (3850)","range":"-200 °C 至 260 °C","cmc":"0,12 °C"},{"name":"Pt 500 (3850)","range":"260 °C 至 800 °C","cmc":"0,45 °C"},{"name":"Pt 1000 (3850)","range":"-200 °C 至 0 °C","cmc":"0,05 °C"},{"name":"Pt 1000 (3850)","range":"0 °C 至 800 °C","cmc":"0,45 °C"},{"name":"Ni 100 (6180)","range":"-60 °C 至 0 °C","cmc":"0,12 °C"},{"name":"Ni 100 (6180)","range":"0 °C","cmc":"0,02 °C"},{"name":"Ni 100 (6180)","range":"0 °C 至 250 °C","cmc":"0,21 °C"},{"name":"Ni 120 (6720)","range":"-80 °C 至 0 °C","cmc":"0,08 °C"},{"name":"Ni 120 (6720)","range":"0 °C 至 260 °C","cmc":"0,11 °C"},{"name":"Ni 1000 (6180)","range":"-50 °C 至 0 °C","cmc":"0,03 °C"},{"name":"Ni 1000 (6180)","range":"0 °C 至 200 °C","cmc":"0,15 °C"}],"parameters_cs":[{"name":"Pt 100 (3850)","range":"-100 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"0 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"30 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"60 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"100 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"200 °C","cmc":"0,05 °C"},{"name":"Pt 100 (3850)","range":"400 °C","cmc":"0,07 °C"},{"name":"Pt 100 (3850)","range":"800 °C","cmc":"0,13 °C"},{"name":"Pt 100 (3850)","range":"-200 °C až 0 °C","cmc":"0,15 °C"},{"name":"Pt 100 (3850)","range":"0 °C až 800 °C","cmc":"0,43 °C"},{"name":"Pt 500 (3850)","range":"-200 °C až 260 °C","cmc":"0,12 °C"},{"name":"Pt 500 (3850)","range":"260 °C až 800 °C","cmc":"0,45 °C"},{"name":"Pt 1000 (3850)","range":"-200 °C až 0 °C","cmc":"0,05 °C"},{"name":"Pt 1000 (3850)","range":"0 °C až 800 °C","cmc":"0,45 °C"},{"name":"Ni 100 (6180)","range":"-60 °C až 0 °C","cmc":"0,12 °C"},{"name":"Ni 100 (6180)","range":"0 °C","cmc":"0,02 °C"},{"name":"Ni 100 (6180)","range":"0 °C až 250 °C","cmc":"0,21 °C"},{"name":"Ni 120 (6720)","range":"-80 °C až 0 °C","cmc":"0,08 °C"},{"name":"Ni 120 (6720)","range":"0 °C až 260 °C","cmc":"0,11 °C"},{"name":"Ni 1000 (6180)","range":"-50 °C až 0 °C","cmc":"0,03 °C"},{"name":"Ni 1000 (6180)","range":"0 °C až 200 °C","cmc":"0,15 °C"}],"technique":"Bezpośrednie generowanie równoważnej rezystancji dla czujników rezystancyjnych (RTD)","technique_en":"Direct generation of equivalent resistance for RTD","technique_zh":"直接产生电阻温度计（RTD）等效电阻","technique_cs":"Přímé generování ekvivalentního odporu pro RTD","techniques":["Bezpośrednie generowanie równoważnej rezystancji dla czujników rezystancyjnych (RTD)"],"techniques_en":["Direct generation of equivalent resistance for RTD"],"techniques_zh":["直接产生电阻温度计（RTD）等效电阻"],"techniques_cs":["Přímé generování ekvivalentního odporu pro RTD"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nPt 100 (3850) -100 °C CMC 0,03 °C\nPt 100 (3850) 0 °C CMC 0,03 °C\nPt 100 (3850) 30 °C CMC 0,04 °C\nPt 100 (3850) 60 °C CMC 0,04 °C\nPt 100 (3850) 100 °C CMC 0,04 °C\nPt 100 (3850) 200 °C CMC 0,05 °C\nPt 100 (3850) 400 °C CMC 0,07 °C\nPt 100 (3850) 800 °C CMC 0,13 °C\nPt 100 (3850) od -200 °C do 0 °C CMC 0,15 °C\nPt 100 (3850) od 0 °C do 800 °C CMC 0,43 °C\nPt 500 (3850) od -200 °C do 260 °C CMC 0,12 °C\nPt 500 (3850) od 260 °C do 800 °C CMC 0,45 °C\nPt 1000 (3850) od -200 °C do 0 °C CMC 0,05 °C\nPt 1000 (3850) od 0 °C do 800 °C CMC 0,45 °C\nNi 100 (6180) od -60 °C do 0 °C CMC 0,12 °C\nNi 100 (6180) 0 °C CMC 0,02 °C\nNi 100 (6180) od 0 °C do 250 °C CMC 0,21 °C\nNi 120 (6720) od -80 °C do 0 °C CMC 0,08 °C\nNi 120 (6720) od 0 °C do 260 °C CMC 0,11 °C\nNi 1000 (6180) od -50 °C do 0 °C CMC 0,03 °C\nNi 1000 (6180) od 0 °C do 200 °C CMC 0,15 °C\nBezpośrednie generowanie równoważnej rezystancji dla czujników rezystancyjnych (RTD)","reference":"KP-PB-122","norm_bases":["KP-PB-122"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kalibratory temperatury, wskaźniki temperatury Wzorcowanie – temperatura Bezpośrednie generowanie równoważnej rezystancji dla czujników rezystancyjnych (RTD) Pt 100 (3850) -100 °C CMC 0,03 °C Pt 100 (3850) 0 °C CMC 0,03 °C Pt 100 (3850) 30 °C CMC 0,04 °C Pt 100 (3850) 60 °C CMC 0,04 °C Pt 100 (3850) 100 °C CMC 0,04 °C Pt 100 (3850) 200 °C CMC 0,05 °C Pt 100 (3850) 400 °C CMC 0,07 °C Pt 100 (3850) 800 °C CMC 0,13 °C Pt 100 (3850) od -200 °C do 0 °C CMC 0,15 °C Pt 100 (3850) od 0 °C do 800 °C CMC 0,43 °C Pt 500 (3850) od -200 °C do 260 °C CMC 0,12 °C Pt 500 (3850) od 260 °C do 800 °C CMC 0,45 °C Pt 1000 (3850) od -200 °C do 0 °C CMC 0,05 °C Pt 1000 (3850) od 0 °C do 800 °C CMC 0,45 °C Ni 100 (6180) od -60 °C do 0 °C CMC 0,12 °C Ni 100 (6180) 0 °C CMC 0,02 °C Ni 100 (6180) od 0 °C do 250 °C CMC 0,21 °C Ni 120 (6720) od -80 °C do 0 °C CMC 0,08 °C Ni 120 (6720) od 0 °C do 260 °C CMC 0,11 °C Ni 1000 (6180) od -50 °C do 0 °C CMC 0,03 °C Ni 1000 (6180) od 0 °C do 200 °C CMC 0,15 °C Teplotní kalibrátory, indikátory teploty Kalibrace – teplota Přímé generování ekvivalentního odporu pro RTD Pt 100 (3850) -100 °C CMC 0,03 °C Pt 100 (3850) 0 °C CMC 0,03 °C Pt 100 (3850) 30 °C CMC 0,04 °C Pt 100 (3850) 60 °C CMC 0,04 °C Pt 100 (3850) 100 °C CMC 0,04 °C Pt 100 (3850) 200 °C CMC 0,05 °C Pt 100 (3850) 400 °C CMC 0,07 °C Pt 100 (3850) 800 °C CMC 0,13 °C Pt 100 (3850) -200 °C až 0 °C CMC 0,15 °C Pt 100 (3850) 0 °C až 800 °C CMC 0,43 °C Pt 500 (3850) -200 °C až 260 °C CMC 0,12 °C Pt 500 (3850) 260 °C až 800 °C CMC 0,45 °C Pt 1000 (3850) -200 °C až 0 °C CMC 0,05 °C Pt 1000 (3850) 0 °C až 800 °C CMC 0,45 °C Ni 100 (6180) -60 °C až 0 °C CMC 0,12 °C Ni 100 (6180) 0 °C CMC 0,02 °C Ni 100 (6180) 0 °C až 250 °C CMC 0,21 °C Ni 120 (6720) -80 °C až 0 °C CMC 0,08 °C Ni 120 (6720) 0 °C až 260 °C CMC 0,11 °C Ni 1000 (6180) -50 °C až 0 °C CMC 0,03 °C Ni 1000 (6180) 0 °C až 200 °C CMC 0,15 °C KP-PB-122 Kalibratory temperatury, wskazniki temperatury Wzorcowanie – temperatura Bezposrednie generowanie rownowaznej rezystancji dla czujnikow rezystancyjnych (RTD) Pt 100 (3850) -100 °C CMC 0,03 °C Pt 100 (3850) 0 °C CMC 0,03 °C Pt 100 (3850) 30 °C CMC 0,04 °C Pt 100 (3850) 60 °C CMC 0,04 °C Pt 100 (3850) 100 °C CMC 0,04 °C Pt 100 (3850) 200 °C CMC 0,05 °C Pt 100 (3850) 400 °C CMC 0,07 °C Pt 100 (3850) 800 °C CMC 0,13 °C Pt 100 (3850) od -200 °C do 0 °C CMC 0,15 °C Pt 100 (3850) od 0 °C do 800 °C CMC 0,43 °C Pt 500 (3850) od -200 °C do 260 °C CMC 0,12 °C Pt 500 (3850) od 260 °C do 800 °C CMC 0,45 °C Pt 1000 (3850) od -200 °C do 0 °C CMC 0,05 °C Pt 1000 (3850) od 0 °C do 800 °C CMC 0,45 °C Ni 100 (6180) od -60 °C do 0 °C CMC 0,12 °C Ni 100 (6180) 0 °C CMC 0,02 °C Ni 100 (6180) od 0 °C do 250 °C CMC 0,21 °C Ni 120 (6720) od -80 °C do 0 °C CMC 0,08 °C Ni 120 (6720) od 0 °C do 260 °C CMC 0,11 °C Ni 1000 (6180) od -50 °C do 0 °C CMC 0,03 °C Ni 1000 (6180) od 0 °C do 200 °C CMC 0,15 °C Teplotni kalibratory, indikatory teploty Kalibrace – teplota Prime generovani ekvivalentniho odporu pro RTD Pt 100 (3850) -100 °C CMC 0,03 °C Pt 100 (3850) 0 °C CMC 0,03 °C Pt 100 (3850) 30 °C CMC 0,04 °C Pt 100 (3850) 60 °C CMC 0,04 °C Pt 100 (3850) 100 °C CMC 0,04 °C Pt 100 (3850) 200 °C CMC 0,05 °C Pt 100 (3850) 400 °C CMC 0,07 °C Pt 100 (3850) 800 °C CMC 0,13 °C Pt 100 (3850) -200 °C az 0 °C CMC 0,15 °C Pt 100 (3850) 0 °C az 800 °C CMC 0,43 °C Pt 500 (3850) -200 °C az 260 °C CMC 0,12 °C Pt 500 (3850) 260 °C az 800 °C CMC 0,45 °C Pt 1000 (3850) -200 °C az 0 °C CMC 0,05 °C Pt 1000 (3850) 0 °C az 800 °C CMC 0,45 °C Ni 100 (6180) -60 °C az 0 °C CMC 0,12 °C Ni 100 (6180) 0 °C CMC 0,02 °C Ni 100 (6180) 0 °C az 250 °C CMC 0,21 °C Ni 120 (6720) -80 °C az 0 °C CMC 0,08 °C Ni 120 (6720) 0 °C az 260 °C CMC 0,11 °C Ni 1000 (6180) -50 °C az 0 °C CMC 0,03 °C Ni 1000 (6180) 0 °C az 200 °C CMC 0,15 °C KP-PB-122","search_en":"Temperature calibrators, temperature indicators Calibration – temperature Direct generation of equivalent resistance for RTD Uherský Brod II CMC for the field of measured quantity: Temperature Direct generation of equivalent resistance for RTD Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 500 (3850) Pt 500 (3850) Pt 1000 (3850) Pt 1000 (3850) Ni 100 (6180) Ni 100 (6180) Ni 100 (6180) Ni 120 (6720) Ni 120 (6720) Ni 1000 (6180) Ni 1000 (6180) KP-PB-122","search_zh":"温度校准器、温度指示器 校准 – 温度 直接产生电阻温度计（RTD）等效电阻 乌赫尔斯基布罗德 II 被测量领域的CMC：温度 直接产生电阻温度计（RTD）等效电阻 Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 500 (3850) Pt 500 (3850) Pt 1000 (3850) Pt 1000 (3850) Ni 100 (6180) Ni 100 (6180) Ni 100 (6180) Ni 120 (6720) Ni 120 (6720) Ni 1000 (6180) Ni 1000 (6180) KP-PB-122","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"Pt 100 (3850)","range":"-100 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"0 °C","cmc":"0,03 °C"},{"name":"Pt 100 (3850)","range":"30 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"60 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"100 °C","cmc":"0,04 °C"},{"name":"Pt 100 (3850)","range":"200 °C","cmc":"0,05 °C"},{"name":"Pt 100 (3850)","range":"400 °C","cmc":"0,07 °C"},{"name":"Pt 100 (3850)","range":"800 °C","cmc":"0,13 °C"},{"name":"Pt 100 (3850)","range":"von -200 °C bis 0 °C","cmc":"0,15 °C"},{"name":"Pt 100 (3850)","range":"von 0 °C bis 800 °C","cmc":"0,43 °C"},{"name":"Pt 500 (3850)","range":"von -200 °C bis 260 °C","cmc":"0,12 °C"},{"name":"Pt 500 (3850)","range":"von 260 °C bis 800 °C","cmc":"0,45 °C"},{"name":"Pt 1000 (3850)","range":"von -200 °C bis 0 °C","cmc":"0,05 °C"},{"name":"Pt 1000 (3850)","range":"von 0 °C bis 800 °C","cmc":"0,45 °C"},{"name":"Ni 100 (6180)","range":"von -60 °C bis 0 °C","cmc":"0,12 °C"},{"name":"Ni 100 (6180)","range":"0 °C","cmc":"0,02 °C"},{"name":"Ni 100 (6180)","range":"von 0 °C bis 250 °C","cmc":"0,21 °C"},{"name":"Ni 120 (6720)","range":"von -80 °C bis 0 °C","cmc":"0,08 °C"},{"name":"Ni 120 (6720)","range":"von 0 °C bis 260 °C","cmc":"0,11 °C"},{"name":"Ni 1000 (6180)","range":"von -50 °C bis 0 °C","cmc":"0,03 °C"},{"name":"Ni 1000 (6180)","range":"von 0 °C bis 200 °C","cmc":"0,15 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Temperaturkalibratoren, Temperaturanzeiger Kalibrierung – Temperatur Direkte Erzeugung des äquivalenten Widerstands für Widerstandsthermometer (RTD) Uherský Brod II CMC für den Messgrößenbereich: Temperatur Direkte Erzeugung des äquivalenten Widerstands für Widerstandsthermometer (RTD) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 100 (3850) Pt 500 (3850) Pt 500 (3850) Pt 1000 (3850) Pt 1000 (3850) Ni 100 (6180) Ni 100 (6180) Ni 100 (6180) Ni 120 (6720) Ni 120 (6720) Ni 1000 (6180) Ni 1000 (6180) KP-PB-122","technique_de":"Direkte Erzeugung des äquivalenten Widerstands für Widerstandsthermometer (RTD)","techniques_de":["Direkte Erzeugung des äquivalenten Widerstands für Widerstandsthermometer (RTD)"],"test_object_de":"Temperaturkalibratoren, Temperaturanzeiger"},{"_id":"76f9df3d1e8856fe8c55570c","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Kalibratory temperatury, wskaźniki temperatury","test_object_en":"Temperature calibrators, temperature indicators","test_object_zh":"温度校准器、温度指示器","test_object_cs":"Teplotní kalibrátory, indikátory teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Pt 100 (385)","range":"od -200 °C do 800 °C","cmc":"0,03 °C"},{"name":"Pt 500 (385)","range":"od -200 °C do 800 °C","cmc":"0,10 °C"},{"name":"Pt 1000 (385)","range":"od -200 °C do 800 °C","cmc":"0,16 °C"},{"name":"Ni 100 (6180)","range":"od -60 °C do 250 °C","cmc":"0,02 °C"},{"name":"Ni 120 (6720)","range":"od -60 °C do 250 °C","cmc":"0,02 °C"},{"name":"Ni 1000 (6180)","range":"od -60 °C do 200 °C","cmc":"0,02 °C"}],"parameters_en":[{"name":"Pt 100 (385)","range":"-200 °C to 800 °C","cmc":"0,03 °C"},{"name":"Pt 500 (385)","range":"-200 °C to 800 °C","cmc":"0,10 °C"},{"name":"Pt 1000 (385)","range":"-200 °C to 800 °C","cmc":"0,16 °C"},{"name":"Ni 100 (6180)","range":"-60 °C to 250 °C","cmc":"0,02 °C"},{"name":"Ni 120 (6720)","range":"-60 °C to 250 °C","cmc":"0,02 °C"},{"name":"Ni 1000 (6180)","range":"-60 °C to 200 °C","cmc":"0,02 °C"}],"parameters_zh":[{"name":"Pt 100 (385)","range":"-200 °C 至 800 °C","cmc":"0,03 °C"},{"name":"Pt 500 (385)","range":"-200 °C 至 800 °C","cmc":"0,10 °C"},{"name":"Pt 1000 (385)","range":"-200 °C 至 800 °C","cmc":"0,16 °C"},{"name":"Ni 100 (6180)","range":"-60 °C 至 250 °C","cmc":"0,02 °C"},{"name":"Ni 120 (6720)","range":"-60 °C 至 250 °C","cmc":"0,02 °C"},{"name":"Ni 1000 (6180)","range":"-60 °C 至 200 °C","cmc":"0,02 °C"}],"parameters_cs":[{"name":"Pt 100 (385)","range":"-200 °C až 800 °C","cmc":"0,03 °C"},{"name":"Pt 500 (385)","range":"-200 °C až 800 °C","cmc":"0,10 °C"},{"name":"Pt 1000 (385)","range":"-200 °C až 800 °C","cmc":"0,16 °C"},{"name":"Ni 100 (6180)","range":"-60 °C až 250 °C","cmc":"0,02 °C"},{"name":"Ni 120 (6720)","range":"-60 °C až 250 °C","cmc":"0,02 °C"},{"name":"Ni 1000 (6180)","range":"-60 °C až 200 °C","cmc":"0,02 °C"}],"technique":"Pomiar bezpośredni równoważnej rezystancji dla czujników rezystancyjnych (RTD)","technique_en":"Direct measurement of equivalent resistance for RTD","technique_zh":"直接测量电阻温度计（RTD）等效电阻","technique_cs":"Přímé měření ekvivalentního odporu pro RTD","techniques":["Pomiar bezpośredni równoważnej rezystancji dla czujników rezystancyjnych (RTD)"],"techniques_en":["Direct measurement of equivalent resistance for RTD"],"techniques_zh":["直接测量电阻温度计（RTD）等效电阻"],"techniques_cs":["Přímé měření ekvivalentního odporu pro RTD"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nPt 100 (385) od -200 °C do 800 °C CMC 0,03 °C\nPt 500 (385) od -200 °C do 800 °C CMC 0,10 °C\nPt 1000 (385) od -200 °C do 800 °C CMC 0,16 °C\nNi 100 (6180) od -60 °C do 250 °C CMC 0,02 °C\nNi 120 (6720) od -60 °C do 250 °C CMC 0,02 °C\nNi 1000 (6180) od -60 °C do 200 °C CMC 0,02 °C\nPomiar bezpośredni równoważnej rezystancji dla czujników rezystancyjnych (RTD)","reference":"KP-PB-122","norm_bases":["KP-PB-122"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kalibratory temperatury, wskaźniki temperatury Wzorcowanie – temperatura Pomiar bezpośredni równoważnej rezystancji dla czujników rezystancyjnych (RTD) Pt 100 (385) od -200 °C do 800 °C CMC 0,03 °C Pt 500 (385) od -200 °C do 800 °C CMC 0,10 °C Pt 1000 (385) od -200 °C do 800 °C CMC 0,16 °C Ni 100 (6180) od -60 °C do 250 °C CMC 0,02 °C Ni 120 (6720) od -60 °C do 250 °C CMC 0,02 °C Ni 1000 (6180) od -60 °C do 200 °C CMC 0,02 °C Teplotní kalibrátory, indikátory teploty Kalibrace – teplota Přímé měření ekvivalentního odporu pro RTD Pt 100 (385) -200 °C až 800 °C CMC 0,03 °C Pt 500 (385) -200 °C až 800 °C CMC 0,10 °C Pt 1000 (385) -200 °C až 800 °C CMC 0,16 °C Ni 100 (6180) -60 °C až 250 °C CMC 0,02 °C Ni 120 (6720) -60 °C až 250 °C CMC 0,02 °C Ni 1000 (6180) -60 °C až 200 °C CMC 0,02 °C KP-PB-122 Kalibratory temperatury, wskazniki temperatury Wzorcowanie – temperatura Pomiar bezposredni rownowaznej rezystancji dla czujnikow rezystancyjnych (RTD) Pt 100 (385) od -200 °C do 800 °C CMC 0,03 °C Pt 500 (385) od -200 °C do 800 °C CMC 0,10 °C Pt 1000 (385) od -200 °C do 800 °C CMC 0,16 °C Ni 100 (6180) od -60 °C do 250 °C CMC 0,02 °C Ni 120 (6720) od -60 °C do 250 °C CMC 0,02 °C Ni 1000 (6180) od -60 °C do 200 °C CMC 0,02 °C Teplotni kalibratory, indikatory teploty Kalibrace – teplota Prime mereni ekvivalentniho odporu pro RTD Pt 100 (385) -200 °C az 800 °C CMC 0,03 °C Pt 500 (385) -200 °C az 800 °C CMC 0,10 °C Pt 1000 (385) -200 °C az 800 °C CMC 0,16 °C Ni 100 (6180) -60 °C az 250 °C CMC 0,02 °C Ni 120 (6720) -60 °C az 250 °C CMC 0,02 °C Ni 1000 (6180) -60 °C az 200 °C CMC 0,02 °C KP-PB-122","search_en":"Temperature calibrators, temperature indicators Calibration – temperature Direct measurement of equivalent resistance for RTD Uherský Brod II CMC for the field of measured quantity: Temperature Direct measurement of equivalent resistance for RTD Pt 100 (385) Pt 500 (385) Pt 1000 (385) Ni 100 (6180) Ni 120 (6720) Ni 1000 (6180) KP-PB-122","search_zh":"温度校准器、温度指示器 校准 – 温度 直接测量电阻温度计（RTD）等效电阻 乌赫尔斯基布罗德 II 被测量领域的CMC：温度 直接测量电阻温度计（RTD）等效电阻 Pt 100 (385) Pt 500 (385) Pt 1000 (385) Ni 100 (6180) Ni 120 (6720) Ni 1000 (6180) KP-PB-122","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"Pt 100 (385)","range":"von -200 °C bis 800 °C","cmc":"0,03 °C"},{"name":"Pt 500 (385)","range":"von -200 °C bis 800 °C","cmc":"0,10 °C"},{"name":"Pt 1000 (385)","range":"von -200 °C bis 800 °C","cmc":"0,16 °C"},{"name":"Ni 100 (6180)","range":"von -60 °C bis 250 °C","cmc":"0,02 °C"},{"name":"Ni 120 (6720)","range":"von -60 °C bis 250 °C","cmc":"0,02 °C"},{"name":"Ni 1000 (6180)","range":"von -60 °C bis 200 °C","cmc":"0,02 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Temperaturkalibratoren, Temperaturanzeiger Kalibrierung – Temperatur Direkte Messung des äquivalenten Widerstands für Widerstandsthermometer (RTD) Uherský Brod II CMC für den Messgrößenbereich: Temperatur Direkte Messung des äquivalenten Widerstands für Widerstandsthermometer (RTD) Pt 100 (385) Pt 500 (385) Pt 1000 (385) Ni 100 (6180) Ni 120 (6720) Ni 1000 (6180) KP-PB-122","technique_de":"Direkte Messung des äquivalenten Widerstands für Widerstandsthermometer (RTD)","techniques_de":["Direkte Messung des äquivalenten Widerstands für Widerstandsthermometer (RTD)"],"test_object_de":"Temperaturkalibratoren, Temperaturanzeiger"},{"_id":"b3ef3dfd498e81799f6bb245","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / źródła napięcia stałego","test_object_en":"DC voltage / DC voltage sources","test_object_zh":"直流电压 / 直流电压源","test_object_cs":"Stejnosměrné napětí / Zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 120 mV","cmc":"8,0 µV/V + 0,2 µV"},{"name":"","range":"od 0,12 V do 1,2 V","cmc":"5,7 µV/V + 0,61 µV"},{"name":"","range":"od 1,2 V do 12 V","cmc":"5,5 µV/V + 6,1 µV"},{"name":"","range":"od 12 V do 120 V","cmc":"8,1 µV/V + 81 µV"},{"name":"","range":"od 120 V do 1050 V","cmc":"8,1 µV/V + 1,2 mV"}],"parameters_en":[{"name":"","range":"from 0 mV to 120 mV","cmc":"8,0 µV/V + 0,2 µV"},{"name":"","range":"from 0,12 V to 1,2 V","cmc":"5,7 µV/V + 0,61 µV"},{"name":"","range":"from 1,2 V to 12 V","cmc":"5,5 µV/V + 6,1 µV"},{"name":"","range":"from 12 V to 120 V","cmc":"8,1 µV/V + 81 µV"},{"name":"","range":"120 V to 1050 V","cmc":"8,1 µV/V + 1,2 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 120 mV","cmc":"8,0 µV/V + 0,2 µV"},{"name":"","range":"0,12 V 至 1,2 V","cmc":"5,7 µV/V + 0,61 µV"},{"name":"","range":"1,2 V 至 12 V","cmc":"5,5 µV/V + 6,1 µV"},{"name":"","range":"12 V 至 120 V","cmc":"8,1 µV/V + 81 µV"},{"name":"","range":"120 V 至 1050 V","cmc":"8,1 µV/V + 1,2 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 120 mV","cmc":"8,0 µV/V + 0,2 µV"},{"name":"","range":"0,12 V až 1,2 V","cmc":"5,7 µV/V + 0,61 µV"},{"name":"","range":"1,2 V až 12 V","cmc":"5,5 µV/V + 6,1 µV"},{"name":"","range":"12 V až 120 V","cmc":"8,1 µV/V + 81 µV"},{"name":"","range":"120 V až 1050 V","cmc":"8,1 µV/V + 1,2 mV"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 120 mV CMC 8,0 µV/V + 0,2 µV\nod 0,12 V do 1,2 V CMC 5,7 µV/V + 0,61 µV\nod 1,2 V do 12 V CMC 5,5 µV/V + 6,1 µV\nod 12 V do 120 V CMC 8,1 µV/V + 81 µV\nod 120 V do 1050 V CMC 8,1 µV/V + 1,2 mV\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP-PB-110","norm_bases":["KP-PB-110"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / źródła napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 mV do 120 mV CMC 8,0 µV/V + 0,2 µV od 0,12 V do 1,2 V CMC 5,7 µV/V + 0,61 µV od 1,2 V do 12 V CMC 5,5 µV/V + 6,1 µV od 12 V do 120 V CMC 8,1 µV/V + 81 µV od 120 V do 1050 V CMC 8,1 µV/V + 1,2 mV Stejnosměrné napětí / Zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 mV až 120 mV CMC 8,0 µV/V + 0,2 µV 0,12 V až 1,2 V CMC 5,7 µV/V + 0,61 µV 1,2 V až 12 V CMC 5,5 µV/V + 6,1 µV 12 V až 120 V CMC 8,1 µV/V + 81 µV 120 V až 1050 V CMC 8,1 µV/V + 1,2 mV KP-PB-110 Napiecie stale / zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 mV do 120 mV CMC 8,0 µV/V + 0,2 µV od 0,12 V do 1,2 V CMC 5,7 µV/V + 0,61 µV od 1,2 V do 12 V CMC 5,5 µV/V + 6,1 µV od 12 V do 120 V CMC 8,1 µV/V + 81 µV od 120 V do 1050 V CMC 8,1 µV/V + 1,2 mV Stejnosmerne napeti / Zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 mV az 120 mV CMC 8,0 µV/V + 0,2 µV 0,12 V az 1,2 V CMC 5,7 µV/V + 0,61 µV 1,2 V az 12 V CMC 5,5 µV/V + 6,1 µV 12 V az 120 V CMC 8,1 µV/V + 81 µV 120 V az 1050 V CMC 8,1 µV/V + 1,2 mV KP-PB-110","search_en":"DC voltage / DC voltage sources Calibration – electrical quantities Direct measurement by a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement by a reference multimeter KP-PB-110","search_zh":"直流电压 / 直流电压源 校准 – 电学量 用标准万用表直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用标准万用表直接测量 KP-PB-110","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 0 mV bis 120 mV","cmc":"8,0 µV/V + 0,2 µV"},{"name":"","range":"von 0,12 V bis 1,2 V","cmc":"5,7 µV/V + 0,61 µV"},{"name":"","range":"von 1,2 V bis 12 V","cmc":"5,5 µV/V + 6,1 µV"},{"name":"","range":"von 12 V bis 120 V","cmc":"8,1 µV/V + 81 µV"},{"name":"","range":"von 120 V bis 1050 V","cmc":"8,1 µV/V + 1,2 mV"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichspannung / Gleichspannungsquellen Kalibrierung – elektrische Größen Direkte Messung mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung mit einem Referenzmultimeter KP-PB-110","technique_de":"Direkte Messung mit einem Referenzmultimeter","techniques_de":["Direkte Messung mit einem Referenzmultimeter"],"test_object_de":"Gleichspannung / Gleichspannungsquellen"},{"_id":"c568dc4e2dc68f6586e8396a","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / źródła napięcia stałego","test_object_en":"DC voltage / DC voltage sources","test_object_zh":"直流电压 / 直流电压源","test_object_cs":"Stejnosměrné napětí / Zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1,05 kV do 10 kV","cmc":"1,2 %"}],"parameters_en":[{"name":"","range":"1,05 kV to 10 kV","cmc":"1,2 %"}],"parameters_zh":[{"name":"","range":"1,05 kV 至 10 kV","cmc":"1,2 %"}],"parameters_cs":[{"name":"","range":"1,05 kV až 10 kV","cmc":"1,2 %"}],"technique":"Pomiar multimetrem wzorcowym z sondą wysokonapięciową","technique_en":"Measurement with a reference multimeter with HV probe","technique_zh":"用带高压探头的标准万用表测量","technique_cs":"Měření etalonovým multimetrem s VN sondou","techniques":["Pomiar multimetrem wzorcowym z sondą wysokonapięciową"],"techniques_en":["Measurement with a reference multimeter with HV probe"],"techniques_zh":["用带高压探头的标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem s VN sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1,05 kV do 10 kV CMC 1,2 %\nPomiar multimetrem wzorcowym z sondą wysokonapięciową","reference":"KP-PB-110","norm_bases":["KP-PB-110"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / źródła napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym z sondą wysokonapięciową od 1,05 kV do 10 kV CMC 1,2 % Stejnosměrné napětí / Zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Měření etalonovým multimetrem s VN sondou 1,05 kV až 10 kV CMC 1,2 % KP-PB-110 Napiecie stale / zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym z sonda wysokonapieciowa od 1,05 kV do 10 kV CMC 1,2 % Stejnosmerne napeti / Zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Mereni etalonovym multimetrem s VN sondou 1,05 kV az 10 kV CMC 1,2 % KP-PB-110","search_en":"DC voltage / DC voltage sources Calibration – electrical quantities Measurement with a reference multimeter with HV probe Uherský Brod II CMC for the field of measured quantity: Electrical quantities Measurement with a reference multimeter with HV probe KP-PB-110","search_zh":"直流电压 / 直流电压源 校准 – 电学量 用带高压探头的标准万用表测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用带高压探头的标准万用表测量 KP-PB-110","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 1,05 kV bis 10 kV","cmc":"1,2 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichspannung / Gleichspannungsquellen Kalibrierung – elektrische Größen Messung mit einem Referenzmultimeter mit Hochspannungstastkopf Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Messung mit einem Referenzmultimeter mit Hochspannungstastkopf KP-PB-110","technique_de":"Messung mit einem Referenzmultimeter mit Hochspannungstastkopf","techniques_de":["Messung mit einem Referenzmultimeter mit Hochspannungstastkopf"],"test_object_de":"Gleichspannung / Gleichspannungsquellen"},{"_id":"3f683140a54365c3f0ccf463","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / przyrządy do pomiaru napięcia stałego","test_object_en":"DC voltage / DC voltage meters","test_object_zh":"直流电压 / 直流电压测量仪器","test_object_cs":"Stejnosměrné napětí / Měřidla stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 200 mV","cmc":"15 µV/V + 2,3 µV"},{"name":"","range":"od 0,2 V do 2 V","cmc":"8,8 µV/V + 2,6 µV"},{"name":"","range":"od 2 V do 20 V","cmc":"7,5 µV/V + 25 µV"},{"name":"","range":"od 20 V do 200 V","cmc":"13 µV/V + 0,28 mV"},{"name":"","range":"od 200 V do 1020 V","cmc":"13 µV/V + 1,8 mV"}],"parameters_en":[{"name":"","range":"from 0 mV to 200 mV","cmc":"15 µV/V + 2,3 µV"},{"name":"","range":"from 0,2 V to 2 V","cmc":"8,8 µV/V + 2,6 µV"},{"name":"","range":"from 2 V to 20 V","cmc":"7,5 µV/V + 25 µV"},{"name":"","range":"from 20 V to 200 V","cmc":"13 µV/V + 0,28 mV"},{"name":"","range":"from 200 V to 1020 V","cmc":"13 µV/V + 1,8 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 200 mV","cmc":"15 µV/V + 2,3 µV"},{"name":"","range":"0,2 V 至 2 V","cmc":"8,8 µV/V + 2,6 µV"},{"name":"","range":"2 V 至 20 V","cmc":"7,5 µV/V + 25 µV"},{"name":"","range":"20 V 至 200 V","cmc":"13 µV/V + 0,28 mV"},{"name":"","range":"200 V 至 1020 V","cmc":"13 µV/V + 1,8 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 200 mV","cmc":"15 µV/V + 2,3 µV"},{"name":"","range":"0,2 V až 2 V","cmc":"8,8 µV/V + 2,6 µV"},{"name":"","range":"2 V až 20 V","cmc":"7,5 µV/V + 25 µV"},{"name":"","range":"20 V až 200 V","cmc":"13 µV/V + 0,28 mV"},{"name":"","range":"200 V až 1020 V","cmc":"13 µV/V + 1,8 mV"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym","technique_en":"Direct measurement on a reference calibrator or comparison with a reference multimeter","technique_zh":"在标准校准器上直接测量或与标准万用表比较","technique_cs":"Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement on a reference calibrator or comparison with a reference multimeter"],"techniques_zh":["在标准校准器上直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 200 mV CMC 15 µV/V + 2,3 µV\nod 0,2 V do 2 V CMC 8,8 µV/V + 2,6 µV\nod 2 V do 20 V CMC 7,5 µV/V + 25 µV\nod 20 V do 200 V CMC 13 µV/V + 0,28 mV\nod 200 V do 1020 V CMC 13 µV/V + 1,8 mV\nPomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym","reference":"KP-PB-110","norm_bases":["KP-PB-110"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / przyrządy do pomiaru napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym od 0 mV do 200 mV CMC 15 µV/V + 2,3 µV od 0,2 V do 2 V CMC 8,8 µV/V + 2,6 µV od 2 V do 20 V CMC 7,5 µV/V + 25 µV od 20 V do 200 V CMC 13 µV/V + 0,28 mV od 200 V do 1020 V CMC 13 µV/V + 1,8 mV Stejnosměrné napětí / Měřidla stejnosměrného napětí Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem 0 mV až 200 mV CMC 15 µV/V + 2,3 µV 0,2 V až 2 V CMC 8,8 µV/V + 2,6 µV 2 V až 20 V CMC 7,5 µV/V + 25 µV 20 V až 200 V CMC 13 µV/V + 0,28 mV 200 V až 1020 V CMC 13 µV/V + 1,8 mV KP-PB-110 Napiecie stale / przyrzady do pomiaru napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym lub porownanie z multimetrem wzorcowym od 0 mV do 200 mV CMC 15 µV/V + 2,3 µV od 0,2 V do 2 V CMC 8,8 µV/V + 2,6 µV od 2 V do 20 V CMC 7,5 µV/V + 25 µV od 20 V do 200 V CMC 13 µV/V + 0,28 mV od 200 V do 1020 V CMC 13 µV/V + 1,8 mV Stejnosmerne napeti / Meridla stejnosmerneho napeti Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru nebo porovnani s etalonovym multimetrem 0 mV az 200 mV CMC 15 µV/V + 2,3 µV 0,2 V az 2 V CMC 8,8 µV/V + 2,6 µV 2 V az 20 V CMC 7,5 µV/V + 25 µV 20 V az 200 V CMC 13 µV/V + 0,28 mV 200 V az 1020 V CMC 13 µV/V + 1,8 mV KP-PB-110","search_en":"DC voltage / DC voltage meters Calibration – electrical quantities Direct measurement on a reference calibrator or comparison with a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator or comparison with a reference multimeter KP-PB-110","search_zh":"直流电压 / 直流电压测量仪器 校准 – 电学量 在标准校准器上直接测量或与标准万用表比较 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在标准校准器上直接测量或与标准万用表比较 KP-PB-110","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 0 mV bis 200 mV","cmc":"15 µV/V + 2,3 µV"},{"name":"","range":"von 0,2 V bis 2 V","cmc":"8,8 µV/V + 2,6 µV"},{"name":"","range":"von 2 V bis 20 V","cmc":"7,5 µV/V + 25 µV"},{"name":"","range":"von 20 V bis 200 V","cmc":"13 µV/V + 0,28 mV"},{"name":"","range":"von 200 V bis 1020 V","cmc":"13 µV/V + 1,8 mV"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichspannung / Gleichspannungsmessgeräte Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter KP-PB-110","technique_de":"Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter","techniques_de":["Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter"],"test_object_de":"Gleichspannung / Gleichspannungsmessgeräte"},{"_id":"3db7304acc70cd739cc9a0ea","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / źródła prądu stałego","test_object_en":"DC current / DC current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / Zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 120 µA","cmc":"23 µA/A + 0,42 nA"},{"name":"","range":"od 0,12 mA do 1,2 mA","cmc":"14 µA/A + 4,1 nA"},{"name":"","range":"od 1,2 mA do 12 mA","cmc":"16 µA/A + 41 nA"},{"name":"","range":"od 12 mA do 120 mA","cmc":"42 µA/A + 0,61 µA"},{"name":"","range":"od 0,12 A do 1,2 A","cmc":"0,020 % + 13 µA"},{"name":"","range":"od 1,2 A do 10 A","cmc":"0,048 % + 0,35 mA"},{"name":"","range":"od 10 A do 30 A","cmc":"0,064 % + 4,4 mA"}],"parameters_en":[{"name":"","range":"from 0 µA to 120 µA","cmc":"23 µA/A + 0,42 nA"},{"name":"","range":"from 0,12 mA to 1,2 mA","cmc":"14 µA/A + 4,1 nA"},{"name":"","range":"from 1,2 mA to 12 mA","cmc":"16 µA/A + 41 nA"},{"name":"","range":"from 12 mA to 120 mA","cmc":"42 µA/A + 0,61 µA"},{"name":"","range":"0,12 A to 1,2 A","cmc":"0,020 % + 13 µA"},{"name":"","range":"1,2 A to 10 A","cmc":"0,048 % + 0,35 mA"},{"name":"","range":"from 10 A to 30 A","cmc":"0,064 % + 4,4 mA"}],"parameters_zh":[{"name":"","range":"0 µA 至 120 µA","cmc":"23 µA/A + 0,42 nA"},{"name":"","range":"0,12 mA 至 1,2 mA","cmc":"14 µA/A + 4,1 nA"},{"name":"","range":"1,2 mA 至 12 mA","cmc":"16 µA/A + 41 nA"},{"name":"","range":"12 mA 至 120 mA","cmc":"42 µA/A + 0,61 µA"},{"name":"","range":"0,12 A 至 1,2 A","cmc":"0,020 % + 13 µA"},{"name":"","range":"1,2 A 至 10 A","cmc":"0,048 % + 0,35 mA"},{"name":"","range":"10 A 至 30 A","cmc":"0,064 % + 4,4 mA"}],"parameters_cs":[{"name":"","range":"0 µA až 120 µA","cmc":"23 µA/A + 0,42 nA"},{"name":"","range":"0,12 mA až 1,2 mA","cmc":"14 µA/A + 4,1 nA"},{"name":"","range":"1,2 mA až 12 mA","cmc":"16 µA/A + 41 nA"},{"name":"","range":"12 mA až 120 mA","cmc":"42 µA/A + 0,61 µA"},{"name":"","range":"0,12 A až 1,2 A","cmc":"0,020 % + 13 µA"},{"name":"","range":"1,2 A až 10 A","cmc":"0,048 % + 0,35 mA"},{"name":"","range":"10 A až 30 A","cmc":"0,064 % + 4,4 mA"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 120 µA CMC 23 µA/A + 0,42 nA\nod 0,12 mA do 1,2 mA CMC 14 µA/A + 4,1 nA\nod 1,2 mA do 12 mA CMC 16 µA/A + 41 nA\nod 12 mA do 120 mA CMC 42 µA/A + 0,61 µA\nod 0,12 A do 1,2 A CMC 0,020 % + 13 µA\nod 1,2 A do 10 A CMC 0,048 % + 0,35 mA\nod 10 A do 30 A CMC 0,064 % + 4,4 mA\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP-PB-111","norm_bases":["KP-PB-111"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 µA do 120 µA CMC 23 µA/A + 0,42 nA od 0,12 mA do 1,2 mA CMC 14 µA/A + 4,1 nA od 1,2 mA do 12 mA CMC 16 µA/A + 41 nA od 12 mA do 120 mA CMC 42 µA/A + 0,61 µA od 0,12 A do 1,2 A CMC 0,020 % + 13 µA od 1,2 A do 10 A CMC 0,048 % + 0,35 mA od 10 A do 30 A CMC 0,064 % + 4,4 mA Stejnosměrný proud / Zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 µA až 120 µA CMC 23 µA/A + 0,42 nA 0,12 mA až 1,2 mA CMC 14 µA/A + 4,1 nA 1,2 mA až 12 mA CMC 16 µA/A + 41 nA 12 mA až 120 mA CMC 42 µA/A + 0,61 µA 0,12 A až 1,2 A CMC 0,020 % + 13 µA 1,2 A až 10 A CMC 0,048 % + 0,35 mA 10 A až 30 A CMC 0,064 % + 4,4 mA KP-PB-111 Prad staly / zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 µA do 120 µA CMC 23 µA/A + 0,42 nA od 0,12 mA do 1,2 mA CMC 14 µA/A + 4,1 nA od 1,2 mA do 12 mA CMC 16 µA/A + 41 nA od 12 mA do 120 mA CMC 42 µA/A + 0,61 µA od 0,12 A do 1,2 A CMC 0,020 % + 13 µA od 1,2 A do 10 A CMC 0,048 % + 0,35 mA od 10 A do 30 A CMC 0,064 % + 4,4 mA Stejnosmerny proud / Zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 µA az 120 µA CMC 23 µA/A + 0,42 nA 0,12 mA az 1,2 mA CMC 14 µA/A + 4,1 nA 1,2 mA az 12 mA CMC 16 µA/A + 41 nA 12 mA az 120 mA CMC 42 µA/A + 0,61 µA 0,12 A az 1,2 A CMC 0,020 % + 13 µA 1,2 A az 10 A CMC 0,048 % + 0,35 mA 10 A az 30 A CMC 0,064 % + 4,4 mA KP-PB-111","search_en":"DC current / DC current sources Calibration – electrical quantities Direct measurement by a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement by a reference multimeter KP-PB-111","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用标准万用表直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用标准万用表直接测量 KP-PB-111","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 0 µA bis 120 µA","cmc":"23 µA/A + 0,42 nA"},{"name":"","range":"von 0,12 mA bis 1,2 mA","cmc":"14 µA/A + 4,1 nA"},{"name":"","range":"von 1,2 mA bis 12 mA","cmc":"16 µA/A + 41 nA"},{"name":"","range":"von 12 mA bis 120 mA","cmc":"42 µA/A + 0,61 µA"},{"name":"","range":"von 0,12 A bis 1,2 A","cmc":"0,020 % + 13 µA"},{"name":"","range":"von 1,2 A bis 10 A","cmc":"0,048 % + 0,35 mA"},{"name":"","range":"von 10 A bis 30 A","cmc":"0,064 % + 4,4 mA"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstrom / Gleichstromquellen Kalibrierung – elektrische Größen Direkte Messung mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung mit einem Referenzmultimeter KP-PB-111","technique_de":"Direkte Messung mit einem Referenzmultimeter","techniques_de":["Direkte Messung mit einem Referenzmultimeter"],"test_object_de":"Gleichstrom / Gleichstromquellen"},{"_id":"80e5e4c94dccd7cd7a0f1571","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / źródła prądu stałego","test_object_en":"DC current / DC current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / Zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 A do 30 A","cmc":"0,031 %"},{"name":"","range":"od 30 A do 70 A","cmc":"0,083 %"},{"name":"","range":"od 70 A do 200 A","cmc":"0,064 %"},{"name":"","range":"od 200 do 300 A","cmc":"0,060 %"}],"parameters_en":[{"name":"","range":"from 10 A to 30 A","cmc":"0,031 %"},{"name":"","range":"30 A to 70 A","cmc":"0,083 %"},{"name":"","range":"70 A to 200 A","cmc":"0,064 %"},{"name":"","range":"200 to 300 A","cmc":"0,060 %"}],"parameters_zh":[{"name":"","range":"10 A 至 30 A","cmc":"0,031 %"},{"name":"","range":"30 A 至 70 A","cmc":"0,083 %"},{"name":"","range":"70 A 至 200 A","cmc":"0,064 %"},{"name":"","range":"200 至 300 A","cmc":"0,060 %"}],"parameters_cs":[{"name":"","range":"10 A až 30 A","cmc":"0,031 %"},{"name":"","range":"30 A až 70 A","cmc":"0,083 %"},{"name":"","range":"70 A až 200 A","cmc":"0,064 %"},{"name":"","range":"200 až 300 A","cmc":"0,060 %"}],"technique":"Pomiar pośredni bocznikiem wzorcowym i multimetrem","technique_en":"Indirect measurement using a reference shunt and multimeter.","technique_zh":"用标准分流器和万用表间接测量","technique_cs":"Nepřímě měření etalonovým bočníkem a multimetrem","techniques":["Pomiar pośredni bocznikiem wzorcowym i multimetrem"],"techniques_en":["Indirect measurement using a reference shunt and multimeter."],"techniques_zh":["用标准分流器和万用表间接测量"],"techniques_cs":["Nepřímě měření etalonovým bočníkem a multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 10 A do 30 A CMC 0,031 %\nod 30 A do 70 A CMC 0,083 %\nod 70 A do 200 A CMC 0,064 %\nod 200 do 300 A CMC 0,060 %\nPomiar pośredni bocznikiem wzorcowym i multimetrem","reference":"KP-PB-111","norm_bases":["KP-PB-111"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego Wzorcowanie – wielkości elektryczne Pomiar pośredni bocznikiem wzorcowym i multimetrem od 10 A do 30 A CMC 0,031 % od 30 A do 70 A CMC 0,083 % od 70 A do 200 A CMC 0,064 % od 200 do 300 A CMC 0,060 % Stejnosměrný proud / Zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Nepřímě měření etalonovým bočníkem a multimetrem 10 A až 30 A CMC 0,031 % 30 A až 70 A CMC 0,083 % 70 A až 200 A CMC 0,064 % 200 až 300 A CMC 0,060 % KP-PB-111 Prad staly / zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar posredni bocznikiem wzorcowym i multimetrem od 10 A do 30 A CMC 0,031 % od 30 A do 70 A CMC 0,083 % od 70 A do 200 A CMC 0,064 % od 200 do 300 A CMC 0,060 % Stejnosmerny proud / Zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Neprime mereni etalonovym bocnikem a multimetrem 10 A az 30 A CMC 0,031 % 30 A az 70 A CMC 0,083 % 70 A az 200 A CMC 0,064 % 200 az 300 A CMC 0,060 % KP-PB-111","search_en":"DC current / DC current sources Calibration – electrical quantities Indirect measurement using a reference shunt and multimeter. Uherský Brod II CMC for the field of measured quantity: Electrical quantities Indirect measurement using a reference shunt and multimeter. KP-PB-111","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用标准分流器和万用表间接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用标准分流器和万用表间接测量 KP-PB-111","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 10 A bis 30 A","cmc":"0,031 %"},{"name":"","range":"von 30 A bis 70 A","cmc":"0,083 %"},{"name":"","range":"von 70 A bis 200 A","cmc":"0,064 %"},{"name":"","range":"von 200 bis 300 A","cmc":"0,060 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstrom / Gleichstromquellen Kalibrierung – elektrische Größen Indirekte Messung mit Normal-Shunt und Multimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Indirekte Messung mit Normal-Shunt und Multimeter KP-PB-111","technique_de":"Indirekte Messung mit Normal-Shunt und Multimeter","techniques_de":["Indirekte Messung mit Normal-Shunt und Multimeter"],"test_object_de":"Gleichstrom / Gleichstromquellen"},{"_id":"6321af1dea0affb71e73db49","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / źródła prądu stałego","test_object_en":"DC current / DC current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / Zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 A do 200 A","cmc":"1,2 % +0,5 A"},{"name":"","range":"od 200 A do 2000 A","cmc":"1,0 % +4,5 A"}],"parameters_en":[{"name":"","range":"0 A to 200 A","cmc":"1,2 % +0,5 A"},{"name":"","range":"from 200 A to 2000 A","cmc":"1,0 % +4,5 A"}],"parameters_zh":[{"name":"","range":"0 A 至 200 A","cmc":"1,2 % +0,5 A"},{"name":"","range":"200 A 至 2000 A","cmc":"1,0 % +4,5 A"}],"parameters_cs":[{"name":"","range":"0 A až 200 A","cmc":"1,2 % +0,5 A"},{"name":"","range":"200 A až 2000 A","cmc":"1,0 % +4,5 A"}],"technique":"Pomiar bezpośredni wzorcowym multimetrem cęgowym lub cęgami prądowymi","technique_en":"Direct measurement by a reference clamp multimeter or a current clamp","technique_zh":"用标准钳形万用表或电流钳直接测量","technique_cs":"Přímé měření etalonovým klešťovým multimetrem nebo proudovými kleštěmi","techniques":["Pomiar bezpośredni wzorcowym multimetrem cęgowym lub cęgami prądowymi"],"techniques_en":["Direct measurement by a reference clamp multimeter or a current clamp"],"techniques_zh":["用标准钳形万用表或电流钳直接测量"],"techniques_cs":["Přímé měření etalonovým klešťovým multimetrem nebo proudovými kleštěmi"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 A do 200 A CMC 1,2 % +0,5 A\nod 200 A do 2000 A CMC 1,0 % +4,5 A\nPomiar bezpośredni wzorcowym multimetrem cęgowym lub cęgami prądowymi","reference":"KP-PB-111","norm_bases":["KP-PB-111"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorcowym multimetrem cęgowym lub cęgami prądowymi od 0 A do 200 A CMC 1,2 % +0,5 A od 200 A do 2000 A CMC 1,0 % +4,5 A Stejnosměrný proud / Zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření etalonovým klešťovým multimetrem nebo proudovými kleštěmi 0 A až 200 A CMC 1,2 % +0,5 A 200 A až 2000 A CMC 1,0 % +4,5 A KP-PB-111 Prad staly / zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcowym multimetrem cegowym lub cegami pradowymi od 0 A do 200 A CMC 1,2 % +0,5 A od 200 A do 2000 A CMC 1,0 % +4,5 A Stejnosmerny proud / Zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym klestovym multimetrem nebo proudovymi klestemi 0 A az 200 A CMC 1,2 % +0,5 A 200 A az 2000 A CMC 1,0 % +4,5 A KP-PB-111","search_en":"DC current / DC current sources Calibration – electrical quantities Direct measurement by a reference clamp multimeter or a current clamp Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement by a reference clamp multimeter or a current clamp KP-PB-111","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用标准钳形万用表或电流钳直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用标准钳形万用表或电流钳直接测量 KP-PB-111","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 0 A bis 200 A","cmc":"1,2 % +0,5 A"},{"name":"","range":"von 200 A bis 2000 A","cmc":"1,0 % +4,5 A"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstrom / Gleichstromquellen Kalibrierung – elektrische Größen Direkte Messung mit einem Referenz-Zangenmultimeter oder einer Stromzange Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung mit einem Referenz-Zangenmultimeter oder einer Stromzange KP-PB-111","technique_de":"Direkte Messung mit einem Referenz-Zangenmultimeter oder einer Stromzange","techniques_de":["Direkte Messung mit einem Referenz-Zangenmultimeter oder einer Stromzange"],"test_object_de":"Gleichstrom / Gleichstromquellen"},{"_id":"43913015078f1b1b4e5db06e","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru prądu stałego","test_object_en":"DC current / DC current meters","test_object_zh":"直流电流 / 直流电流测量仪器","test_object_cs":"Stejnosměrný proud / Měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 200 µA","cmc":"91 µA/A + 10 nA"},{"name":"","range":"od 0,2 mA do 2 mA","cmc":"46 µA/A + 30 nA"},{"name":"","range":"od 2 mA do 20 mA","cmc":"46 µA/A + 0,21 µA"},{"name":"","range":"od 20 mA do 200 mA","cmc":"51 µA/A + 2,2 µA"},{"name":"","range":"od 0,2 A do 2 A","cmc":"87 µA/A + 32 µA"},{"name":"","range":"od 2 A do 20 A","cmc":"0,023 % + 0,30 mA"},{"name":"","range":"od 20 A do 30 A","cmc":"0,034 % + 0,94 mA"}],"parameters_en":[{"name":"","range":"from 0 µA to 200 µA","cmc":"91 µA/A + 10 nA"},{"name":"","range":"from 0,2 mA to 2 mA","cmc":"46 µA/A + 30 nA"},{"name":"","range":"from 2 mA to 20 mA","cmc":"46 µA/A + 0,21 µA"},{"name":"","range":"from 20 mA to 200 mA","cmc":"51 µA/A + 2,2 µA"},{"name":"","range":"from 0,2 A to 2 A","cmc":"87 µA/A + 32 µA"},{"name":"","range":"from 2 A to 20 A","cmc":"0,023 % + 0,30 mA"},{"name":"","range":"from 20 A to 30 A","cmc":"0,034 % + 0,94 mA"}],"parameters_zh":[{"name":"","range":"0 µA 至 200 µA","cmc":"91 µA/A + 10 nA"},{"name":"","range":"0,2 mA 至 2 mA","cmc":"46 µA/A + 30 nA"},{"name":"","range":"2 mA 至 20 mA","cmc":"46 µA/A + 0,21 µA"},{"name":"","range":"20 mA 至 200 mA","cmc":"51 µA/A + 2,2 µA"},{"name":"","range":"0,2 A 至 2 A","cmc":"87 µA/A + 32 µA"},{"name":"","range":"2 A 至 20 A","cmc":"0,023 % + 0,30 mA"},{"name":"","range":"20 A 至 30 A","cmc":"0,034 % + 0,94 mA"}],"parameters_cs":[{"name":"","range":"0 µA až 200 µA","cmc":"91 µA/A + 10 nA"},{"name":"","range":"0,2 mA až 2 mA","cmc":"46 µA/A + 30 nA"},{"name":"","range":"2 mA až 20 mA","cmc":"46 µA/A + 0,21 µA"},{"name":"","range":"20 mA až 200 mA","cmc":"51 µA/A + 2,2 µA"},{"name":"","range":"0,2 A až 2 A","cmc":"87 µA/A + 32 µA"},{"name":"","range":"2 A až 20 A","cmc":"0,023 % + 0,30 mA"},{"name":"","range":"20 A až 30 A","cmc":"0,034 % + 0,94 mA"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym","technique_en":"Direct measurement on a reference calibrator or comparison with a reference multimeter","technique_zh":"在标准校准器上直接测量或与标准万用表比较","technique_cs":"Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement on a reference calibrator or comparison with a reference multimeter"],"techniques_zh":["在标准校准器上直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 200 µA CMC 91 µA/A + 10 nA\nod 0,2 mA do 2 mA CMC 46 µA/A + 30 nA\nod 2 mA do 20 mA CMC 46 µA/A + 0,21 µA\nod 20 mA do 200 mA CMC 51 µA/A + 2,2 µA\nod 0,2 A do 2 A CMC 87 µA/A + 32 µA\nod 2 A do 20 A CMC 0,023 % + 0,30 mA\nod 20 A do 30 A CMC 0,034 % + 0,94 mA\nPomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym","reference":"KP-PB-111","norm_bases":["KP-PB-111"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym od 0 µA do 200 µA CMC 91 µA/A + 10 nA od 0,2 mA do 2 mA CMC 46 µA/A + 30 nA od 2 mA do 20 mA CMC 46 µA/A + 0,21 µA od 20 mA do 200 mA CMC 51 µA/A + 2,2 µA od 0,2 A do 2 A CMC 87 µA/A + 32 µA od 2 A do 20 A CMC 0,023 % + 0,30 mA od 20 A do 30 A CMC 0,034 % + 0,94 mA Stejnosměrný proud / Měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem 0 µA až 200 µA CMC 91 µA/A + 10 nA 0,2 mA až 2 mA CMC 46 µA/A + 30 nA 2 mA až 20 mA CMC 46 µA/A + 0,21 µA 20 mA až 200 mA CMC 51 µA/A + 2,2 µA 0,2 A až 2 A CMC 87 µA/A + 32 µA 2 A až 20 A CMC 0,023 % + 0,30 mA 20 A až 30 A CMC 0,034 % + 0,94 mA KP-PB-111 Prad staly / przyrzady do pomiaru pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym lub porownanie z multimetrem wzorcowym od 0 µA do 200 µA CMC 91 µA/A + 10 nA od 0,2 mA do 2 mA CMC 46 µA/A + 30 nA od 2 mA do 20 mA CMC 46 µA/A + 0,21 µA od 20 mA do 200 mA CMC 51 µA/A + 2,2 µA od 0,2 A do 2 A CMC 87 µA/A + 32 µA od 2 A do 20 A CMC 0,023 % + 0,30 mA od 20 A do 30 A CMC 0,034 % + 0,94 mA Stejnosmerny proud / Meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru nebo porovnani s etalonovym multimetrem 0 µA az 200 µA CMC 91 µA/A + 10 nA 0,2 mA az 2 mA CMC 46 µA/A + 30 nA 2 mA az 20 mA CMC 46 µA/A + 0,21 µA 20 mA az 200 mA CMC 51 µA/A + 2,2 µA 0,2 A az 2 A CMC 87 µA/A + 32 µA 2 A az 20 A CMC 0,023 % + 0,30 mA 20 A az 30 A CMC 0,034 % + 0,94 mA KP-PB-111","search_en":"DC current / DC current meters Calibration – electrical quantities Direct measurement on a reference calibrator or comparison with a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator or comparison with a reference multimeter KP-PB-111","search_zh":"直流电流 / 直流电流测量仪器 校准 – 电学量 在标准校准器上直接测量或与标准万用表比较 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在标准校准器上直接测量或与标准万用表比较 KP-PB-111","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 0 µA bis 200 µA","cmc":"91 µA/A + 10 nA"},{"name":"","range":"von 0,2 mA bis 2 mA","cmc":"46 µA/A + 30 nA"},{"name":"","range":"von 2 mA bis 20 mA","cmc":"46 µA/A + 0,21 µA"},{"name":"","range":"von 20 mA bis 200 mA","cmc":"51 µA/A + 2,2 µA"},{"name":"","range":"von 0,2 A bis 2 A","cmc":"87 µA/A + 32 µA"},{"name":"","range":"von 2 A bis 20 A","cmc":"0,023 % + 0,30 mA"},{"name":"","range":"von 20 A bis 30 A","cmc":"0,034 % + 0,94 mA"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstrom / Gleichstrommessgeräte Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter KP-PB-111","technique_de":"Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter","techniques_de":["Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter"],"test_object_de":"Gleichstrom / Gleichstrommessgeräte"},{"_id":"2f6461dce91d295a8d91bc63","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru prądu stałego","test_object_en":"DC current / DC current meters","test_object_zh":"直流电流 / 直流电流测量仪器","test_object_cs":"Stejnosměrný proud / Měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 30 A do 60 A","cmc":"0,64 % + 0,10 A"},{"name":"","range":"od 60 A do 300 A","cmc":"0,78 % + 0,13 A"},{"name":"","range":"od 300 A do 1500 A","cmc":"0,60 % + 0,42 A"}],"parameters_en":[{"name":"","range":"30 A to 60 A","cmc":"0,64 % + 0,10 A"},{"name":"","range":"60 A to 300 A","cmc":"0,78 % + 0,13 A"},{"name":"","range":"300 A to 1500 A","cmc":"0,60 % + 0,42 A"}],"parameters_zh":[{"name":"","range":"30 A 至 60 A","cmc":"0,64 % + 0,10 A"},{"name":"","range":"60 A 至 300 A","cmc":"0,78 % + 0,13 A"},{"name":"","range":"300 A 至 1500 A","cmc":"0,60 % + 0,42 A"}],"parameters_cs":[{"name":"","range":"30 A až 60 A","cmc":"0,64 % + 0,10 A"},{"name":"","range":"60 A až 300 A","cmc":"0,78 % + 0,13 A"},{"name":"","range":"300 A až 1500 A","cmc":"0,60 % + 0,42 A"}],"technique":"Pomiar prądu symulowanego kalibratorem z cewką prądową","technique_en":"Measurement of a current simulated by a calibrator with current coil","technique_zh":"测量由带电流线圈的校准器模拟的电流","technique_cs":"Měření proudu simulovaného kalibrátorem s proudovou cívkou","techniques":["Pomiar prądu symulowanego kalibratorem z cewką prądową"],"techniques_en":["Measurement of a current simulated by a calibrator with current coil"],"techniques_zh":["测量由带电流线圈的校准器模拟的电流"],"techniques_cs":["Měření proudu simulovaného kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 30 A do 60 A CMC 0,64 % + 0,10 A\nod 60 A do 300 A CMC 0,78 % + 0,13 A\nod 300 A do 1500 A CMC 0,60 % + 0,42 A\nPomiar prądu symulowanego kalibratorem z cewką prądową","reference":"KP-PB-111","norm_bases":["KP-PB-111"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru prądu stałego Wzorcowanie – wielkości elektryczne Pomiar prądu symulowanego kalibratorem z cewką prądową od 30 A do 60 A CMC 0,64 % + 0,10 A od 60 A do 300 A CMC 0,78 % + 0,13 A od 300 A do 1500 A CMC 0,60 % + 0,42 A Stejnosměrný proud / Měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Měření proudu simulovaného kalibrátorem s proudovou cívkou 30 A až 60 A CMC 0,64 % + 0,10 A 60 A až 300 A CMC 0,78 % + 0,13 A 300 A až 1500 A CMC 0,60 % + 0,42 A KP-PB-111 Prad staly / przyrzady do pomiaru pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar pradu symulowanego kalibratorem z cewka pradowa od 30 A do 60 A CMC 0,64 % + 0,10 A od 60 A do 300 A CMC 0,78 % + 0,13 A od 300 A do 1500 A CMC 0,60 % + 0,42 A Stejnosmerny proud / Meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Mereni proudu simulovaneho kalibratorem s proudovou civkou 30 A az 60 A CMC 0,64 % + 0,10 A 60 A az 300 A CMC 0,78 % + 0,13 A 300 A az 1500 A CMC 0,60 % + 0,42 A KP-PB-111","search_en":"DC current / DC current meters Calibration – electrical quantities Measurement of a current simulated by a calibrator with current coil Uherský Brod II CMC for the field of measured quantity: Electrical quantities Measurement of a current simulated by a calibrator with current coil KP-PB-111","search_zh":"直流电流 / 直流电流测量仪器 校准 – 电学量 测量由带电流线圈的校准器模拟的电流 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 测量由带电流线圈的校准器模拟的电流 KP-PB-111","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 30 A bis 60 A","cmc":"0,64 % + 0,10 A"},{"name":"","range":"von 60 A bis 300 A","cmc":"0,78 % + 0,13 A"},{"name":"","range":"von 300 A bis 1500 A","cmc":"0,60 % + 0,42 A"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstrom / Gleichstrommessgeräte Kalibrierung – elektrische Größen Messung eines mit dem Kalibrator mit Stromspule simulierten Stroms Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Messung eines mit dem Kalibrator mit Stromspule simulierten Stroms KP-PB-111","technique_de":"Messung eines mit dem Kalibrator mit Stromspule simulierten Stroms","techniques_de":["Messung eines mit dem Kalibrator mit Stromspule simulierten Stroms"],"test_object_de":"Gleichstrom / Gleichstrommessgeräte"},{"_id":"8b69fc1f01f4e833619ef253","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / źródła napięcia przemiennego","test_object_en":"AC voltage / AC voltage sources","test_object_zh":"交流电压 / 交流电压源","test_object_cs":"Střídavé napětí / Zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 40 Hz","range":"od 0 mV do 100 mV","cmc":"0,061 % + 19 µV"},{"name":"40 Hz do 200 Hz","range":"od 0 mV do 100 mV","cmc":"0,027 % + 15 µV"},{"name":"200 Hz do 2 kHz","range":"od 0 mV do 100 mV","cmc":"0,023 % + 13 µV"},{"name":"2 kHz do 20 kHz","range":"od 0 mV do 100 mV","cmc":"0,032 % + 14 µV"},{"name":"20 kHz do 100 kHz","range":"od 0 mV do 100 mV","cmc":"0,081 % + 51 µV"},{"name":"10 Hz do 40 Hz","range":"od 0,1 V do 1 V","cmc":"0,048 % + 0,24 mV"},{"name":"40 Hz do 200 Hz","range":"od 0,1 V do 1 V","cmc":"0,023 % + 61 µV"},{"name":"200 Hz do 2 kHz","range":"od 0,1 V do 1 V","cmc":"0,018 % + 61 µV"},{"name":"2 kHz do 20 kHz","range":"od 0,1 V do 1 V","cmc":"0,030 % + 0,10 mV"},{"name":"20 kHz do 100 kHz","range":"od 0,1 V do 1 V","cmc":"0,072 % + 0,50 mV"},{"name":"100 kHz do 1 MHz","range":"od 0,1 V do 1 V","cmc":"1,2 % + 25 mV"},{"name":"10 Hz do 40 Hz","range":"od 1 V do 10 V","cmc":"0,048 % + 2,3 mV"},{"name":"40 Hz do 200 Hz","range":"od 1 V do 10 V","cmc":"0,021 % + 0,61 mV"},{"name":"200 Hz do 2 kHz","range":"od 1 V do 10 V","cmc":"0,018 % + 0,61 mV"},{"name":"2 kHz do 20 kHz","range":"od 1 V do 10 V","cmc":"0,030 % + 1,0 mV"},{"name":"20 kHz do 100 kHz","range":"od 1 V do 10 V","cmc":"0,072 % + 5,0 mV"},{"name":"100 kHz do 200 kHz","range":"od 1 V do 10 V","cmc":"1,2 % + 0,25 V"},{"name":"10 Hz do 40 Hz","range":"od 10 V do 100 V","cmc":"0,060 % + 23 mV"},{"name":"40 Hz do 200 Hz","range":"od 10 V do 100 V","cmc":"0,024 % + 10 mV"},{"name":"200 Hz do 2 kHz","range":"od 10 V do 100 V","cmc":"0,022 % + 7,1 mV"},{"name":"2 kHz do 20 kHz","range":"od 10 V do 100 V","cmc":"0,033 % + 11 mV"},{"name":"20 kHz do 50 kHz","range":"od 10 V do 100 V","cmc":"0,11 % + 62 mV"},{"name":"10 Hz do 40 Hz","range":"od 100 V do 1000 V","cmc":"0,060 % + 0,16 V"},{"name":"40 Hz do 200 Hz","range":"od 100 V do 1000 V","cmc":"0,021 % + 0,10 V"},{"name":"200 Hz do 2 kHz","range":"od 100 V do 1000 V","cmc":"0,022 % + 0,10 V"},{"name":"2 kHz do 10 kHz","range":"od 100 V do 1000 V","cmc":"0,037 % + 0,11 V"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"0 mV to 100 mV","cmc":"0,061 % + 19 µV"},{"name":"40 Hz to 200 Hz","range":"0 mV to 100 mV","cmc":"0,027 % + 15 µV"},{"name":"200 Hz to 2 kHz","range":"0 mV to 100 mV","cmc":"0,023 % + 13 µV"},{"name":"2 kHz to 20 kHz","range":"0 mV to 100 mV","cmc":"0,032 % + 14 µV"},{"name":"20 kHz to 100 kHz","range":"0 mV to 100 mV","cmc":"0,081 % + 51 µV"},{"name":"10 Hz to 40 Hz","range":"0,1 V to 1 V","cmc":"0,048 % + 0,24 mV"},{"name":"40 Hz to 200 Hz","range":"0,1 V to 1 V","cmc":"0,023 % + 61 µV"},{"name":"200 Hz to 2 kHz","range":"0,1 V to 1 V","cmc":"0,018 % + 61 µV"},{"name":"2 kHz to 20 kHz","range":"0,1 V to 1 V","cmc":"0,030 % + 0,10 mV"},{"name":"20 kHz to 100 kHz","range":"0,1 V to 1 V","cmc":"0,072 % + 0,50 mV"},{"name":"100 kHz to 1 MHz","range":"0,1 V to 1 V","cmc":"1,2 % + 25 mV"},{"name":"10 Hz to 40 Hz","range":"1 V to 10 V","cmc":"0,048 % + 2,3 mV"},{"name":"40 Hz to 200 Hz","range":"1 V to 10 V","cmc":"0,021 % + 0,61 mV"},{"name":"200 Hz to 2 kHz","range":"1 V to 10 V","cmc":"0,018 % + 0,61 mV"},{"name":"2 kHz to 20 kHz","range":"1 V to 10 V","cmc":"0,030 % + 1,0 mV"},{"name":"20 kHz to 100 kHz","range":"1 V to 10 V","cmc":"0,072 % + 5,0 mV"},{"name":"100 kHz to 200 kHz","range":"1 V to 10 V","cmc":"1,2 % + 0,25 V"},{"name":"10 Hz to 40 Hz","range":"10 V to 100 V","cmc":"0,060 % + 23 mV"},{"name":"40 Hz to 200 Hz","range":"10 V to 100 V","cmc":"0,024 % + 10 mV"},{"name":"200 Hz to 2 kHz","range":"10 V to 100 V","cmc":"0,022 % + 7,1 mV"},{"name":"2 kHz to 20 kHz","range":"10 V to 100 V","cmc":"0,033 % + 11 mV"},{"name":"20 kHz to 50 kHz","range":"10 V to 100 V","cmc":"0,11 % + 62 mV"},{"name":"10 Hz to 40 Hz","range":"100 V to 1000 V","cmc":"0,060 % + 0,16 V"},{"name":"40 Hz to 200 Hz","range":"100 V to 1000 V","cmc":"0,021 % + 0,10 V"},{"name":"200 Hz to 2 kHz","range":"100 V to 1000 V","cmc":"0,022 % + 0,10 V"},{"name":"2 kHz to 10 kHz","range":"100 V to 1000 V","cmc":"0,037 % + 0,11 V"}],"parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"0 mV 至 100 mV","cmc":"0,061 % + 19 µV"},{"name":"40 Hz 至 200 Hz","range":"0 mV 至 100 mV","cmc":"0,027 % + 15 µV"},{"name":"200 Hz 至 2 kHz","range":"0 mV 至 100 mV","cmc":"0,023 % + 13 µV"},{"name":"2 kHz 至 20 kHz","range":"0 mV 至 100 mV","cmc":"0,032 % + 14 µV"},{"name":"20 kHz 至 100 kHz","range":"0 mV 至 100 mV","cmc":"0,081 % + 51 µV"},{"name":"10 Hz 至 40 Hz","range":"0,1 V 至 1 V","cmc":"0,048 % + 0,24 mV"},{"name":"40 Hz 至 200 Hz","range":"0,1 V 至 1 V","cmc":"0,023 % + 61 µV"},{"name":"200 Hz 至 2 kHz","range":"0,1 V 至 1 V","cmc":"0,018 % + 61 µV"},{"name":"2 kHz 至 20 kHz","range":"0,1 V 至 1 V","cmc":"0,030 % + 0,10 mV"},{"name":"20 kHz 至 100 kHz","range":"0,1 V 至 1 V","cmc":"0,072 % + 0,50 mV"},{"name":"100 kHz 至 1 MHz","range":"0,1 V 至 1 V","cmc":"1,2 % + 25 mV"},{"name":"10 Hz 至 40 Hz","range":"1 V 至 10 V","cmc":"0,048 % + 2,3 mV"},{"name":"40 Hz 至 200 Hz","range":"1 V 至 10 V","cmc":"0,021 % + 0,61 mV"},{"name":"200 Hz 至 2 kHz","range":"1 V 至 10 V","cmc":"0,018 % + 0,61 mV"},{"name":"2 kHz 至 20 kHz","range":"1 V 至 10 V","cmc":"0,030 % + 1,0 mV"},{"name":"20 kHz 至 100 kHz","range":"1 V 至 10 V","cmc":"0,072 % + 5,0 mV"},{"name":"100 kHz 至 200 kHz","range":"1 V 至 10 V","cmc":"1,2 % + 0,25 V"},{"name":"10 Hz 至 40 Hz","range":"10 V 至 100 V","cmc":"0,060 % + 23 mV"},{"name":"40 Hz 至 200 Hz","range":"10 V 至 100 V","cmc":"0,024 % + 10 mV"},{"name":"200 Hz 至 2 kHz","range":"10 V 至 100 V","cmc":"0,022 % + 7,1 mV"},{"name":"2 kHz 至 20 kHz","range":"10 V 至 100 V","cmc":"0,033 % + 11 mV"},{"name":"20 kHz 至 50 kHz","range":"10 V 至 100 V","cmc":"0,11 % + 62 mV"},{"name":"10 Hz 至 40 Hz","range":"100 V 至 1000 V","cmc":"0,060 % + 0,16 V"},{"name":"40 Hz 至 200 Hz","range":"100 V 至 1000 V","cmc":"0,021 % + 0,10 V"},{"name":"200 Hz 至 2 kHz","range":"100 V 至 1000 V","cmc":"0,022 % + 0,10 V"},{"name":"2 kHz 至 10 kHz","range":"100 V 至 1000 V","cmc":"0,037 % + 0,11 V"}],"parameters_cs":[{"name":"10 Hz až 40 Hz","range":"0 mV až 100 mV","cmc":"0,061 % + 19 µV"},{"name":"40 Hz až 200 Hz","range":"0 mV až 100 mV","cmc":"0,027 % + 15 µV"},{"name":"200 Hz až 2 kHz","range":"0 mV až 100 mV","cmc":"0,023 % + 13 µV"},{"name":"2 kHz až 20 kHz","range":"0 mV až 100 mV","cmc":"0,032 % + 14 µV"},{"name":"20 kHz až 100 kHz","range":"0 mV až 100 mV","cmc":"0,081 % + 51 µV"},{"name":"10 Hz až 40 Hz","range":"0,1 V až 1 V","cmc":"0,048 % + 0,24 mV"},{"name":"40 Hz až 200 Hz","range":"0,1 V až 1 V","cmc":"0,023 % + 61 µV"},{"name":"200 Hz až 2 kHz","range":"0,1 V až 1 V","cmc":"0,018 % + 61 µV"},{"name":"2 kHz až 20 kHz","range":"0,1 V až 1 V","cmc":"0,030 % + 0,10 mV"},{"name":"20 kHz až 100 kHz","range":"0,1 V až 1 V","cmc":"0,072 % + 0,50 mV"},{"name":"100 kHz až 1 MHz","range":"0,1 V až 1 V","cmc":"1,2 % + 25 mV"},{"name":"10 Hz až 40 Hz","range":"1 V až 10 V","cmc":"0,048 % + 2,3 mV"},{"name":"40 Hz až 200 Hz","range":"1 V až 10 V","cmc":"0,021 % + 0,61 mV"},{"name":"200 Hz až 2 kHz","range":"1 V až 10 V","cmc":"0,018 % + 0,61 mV"},{"name":"2 kHz až 20 kHz","range":"1 V až 10 V","cmc":"0,030 % + 1,0 mV"},{"name":"20 kHz až 100 kHz","range":"1 V až 10 V","cmc":"0,072 % + 5,0 mV"},{"name":"100 kHz až 200 kHz","range":"1 V až 10 V","cmc":"1,2 % + 0,25 V"},{"name":"10 Hz až 40 Hz","range":"10 V až 100 V","cmc":"0,060 % + 23 mV"},{"name":"40 Hz až 200 Hz","range":"10 V až 100 V","cmc":"0,024 % + 10 mV"},{"name":"200 Hz až 2 kHz","range":"10 V až 100 V","cmc":"0,022 % + 7,1 mV"},{"name":"2 kHz až 20 kHz","range":"10 V až 100 V","cmc":"0,033 % + 11 mV"},{"name":"20 kHz až 50 kHz","range":"10 V až 100 V","cmc":"0,11 % + 62 mV"},{"name":"10 Hz až 40 Hz","range":"100 V až 1000 V","cmc":"0,060 % + 0,16 V"},{"name":"40 Hz až 200 Hz","range":"100 V až 1000 V","cmc":"0,021 % + 0,10 V"},{"name":"200 Hz až 2 kHz","range":"100 V až 1000 V","cmc":"0,022 % + 0,10 V"},{"name":"2 kHz až 10 kHz","range":"100 V až 1000 V","cmc":"0,037 % + 0,11 V"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 40 Hz od 0 mV do 100 mV CMC 0,061 % + 19 µV\n40 Hz do 200 Hz od 0 mV do 100 mV CMC 0,027 % + 15 µV\n200 Hz do 2 kHz od 0 mV do 100 mV CMC 0,023 % + 13 µV\n2 kHz do 20 kHz od 0 mV do 100 mV CMC 0,032 % + 14 µV\n20 kHz do 100 kHz od 0 mV do 100 mV CMC 0,081 % + 51 µV\n10 Hz do 40 Hz od 0,1 V do 1 V CMC 0,048 % + 0,24 mV\n40 Hz do 200 Hz od 0,1 V do 1 V CMC 0,023 % + 61 µV\n200 Hz do 2 kHz od 0,1 V do 1 V CMC 0,018 % + 61 µV\n2 kHz do 20 kHz od 0,1 V do 1 V CMC 0,030 % + 0,10 mV\n20 kHz do 100 kHz od 0,1 V do 1 V CMC 0,072 % + 0,50 mV\n100 kHz do 1 MHz od 0,1 V do 1 V CMC 1,2 % + 25 mV\n10 Hz do 40 Hz od 1 V do 10 V CMC 0,048 % + 2,3 mV\n40 Hz do 200 Hz od 1 V do 10 V CMC 0,021 % + 0,61 mV\n200 Hz do 2 kHz od 1 V do 10 V CMC 0,018 % + 0,61 mV\n2 kHz do 20 kHz od 1 V do 10 V CMC 0,030 % + 1,0 mV\n20 kHz do 100 kHz od 1 V do 10 V CMC 0,072 % + 5,0 mV\n100 kHz do 200 kHz od 1 V do 10 V CMC 1,2 % + 0,25 V\n10 Hz do 40 Hz od 10 V do 100 V CMC 0,060 % + 23 mV\n40 Hz do 200 Hz od 10 V do 100 V CMC 0,024 % + 10 mV\n200 Hz do 2 kHz od 10 V do 100 V CMC 0,022 % + 7,1 mV\n2 kHz do 20 kHz od 10 V do 100 V CMC 0,033 % + 11 mV\n20 kHz do 50 kHz od 10 V do 100 V CMC 0,11 % + 62 mV\n10 Hz do 40 Hz od 100 V do 1000 V CMC 0,060 % + 0,16 V\n40 Hz do 200 Hz od 100 V do 1000 V CMC 0,021 % + 0,10 V\n200 Hz do 2 kHz od 100 V do 1000 V CMC 0,022 % + 0,10 V\n2 kHz do 10 kHz od 100 V do 1000 V CMC 0,037 % + 0,11 V\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP-PB-112","norm_bases":["KP-PB-112"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 10 Hz do 40 Hz od 0 mV do 100 mV CMC 0,061 % + 19 µV 40 Hz do 200 Hz od 0 mV do 100 mV CMC 0,027 % + 15 µV 200 Hz do 2 kHz od 0 mV do 100 mV CMC 0,023 % + 13 µV 2 kHz do 20 kHz od 0 mV do 100 mV CMC 0,032 % + 14 µV 20 kHz do 100 kHz od 0 mV do 100 mV CMC 0,081 % + 51 µV 10 Hz do 40 Hz od 0,1 V do 1 V CMC 0,048 % + 0,24 mV 40 Hz do 200 Hz od 0,1 V do 1 V CMC 0,023 % + 61 µV 200 Hz do 2 kHz od 0,1 V do 1 V CMC 0,018 % + 61 µV 2 kHz do 20 kHz od 0,1 V do 1 V CMC 0,030 % + 0,10 mV 20 kHz do 100 kHz od 0,1 V do 1 V CMC 0,072 % + 0,50 mV 100 kHz do 1 MHz od 0,1 V do 1 V CMC 1,2 % + 25 mV 10 Hz do 40 Hz od 1 V do 10 V CMC 0,048 % + 2,3 mV 40 Hz do 200 Hz od 1 V do 10 V CMC 0,021 % + 0,61 mV 200 Hz do 2 kHz od 1 V do 10 V CMC 0,018 % + 0,61 mV 2 kHz do 20 kHz od 1 V do 10 V CMC 0,030 % + 1,0 mV 20 kHz do 100 kHz od 1 V do 10 V CMC 0,072 % + 5,0 mV 100 kHz do 200 kHz od 1 V do 10 V CMC 1,2 % + 0,25 V 10 Hz do 40 Hz od 10 V do 100 V CMC 0,060 % + 23 mV 40 Hz do 200 Hz od 10 V do 100 V CMC 0,024 % + 10 mV 200 Hz do 2 kHz od 10 V do 100 V CMC 0,022 % + 7,1 mV 2 kHz do 20 kHz od 10 V do 100 V CMC 0,033 % + 11 mV 20 kHz do 50 kHz od 10 V do 100 V CMC 0,11 % + 62 mV 10 Hz do 40 Hz od 100 V do 1000 V CMC 0,060 % + 0,16 V 40 Hz do 200 Hz od 100 V do 1000 V CMC 0,021 % + 0,10 V 200 Hz do 2 kHz od 100 V do 1000 V CMC 0,022 % + 0,10 V 2 kHz do 10 kHz od 100 V do 1000 V CMC 0,037 % + 0,11 V Střídavé napětí / Zdroje střídavého napětí Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 10 Hz až 40 Hz 0 mV až 100 mV CMC 0,061 % + 19 µV 40 Hz až 200 Hz 0 mV až 100 mV CMC 0,027 % + 15 µV 200 Hz až 2 kHz 0 mV až 100 mV CMC 0,023 % + 13 µV 2 kHz až 20 kHz 0 mV až 100 mV CMC 0,032 % + 14 µV 20 kHz až 100 kHz 0 mV až 100 mV CMC 0,081 % + 51 µV 10 Hz až 40 Hz 0,1 V až 1 V CMC 0,048 % + 0,24 mV 40 Hz až 200 Hz 0,1 V až 1 V CMC 0,023 % + 61 µV 200 Hz až 2 kHz 0,1 V až 1 V CMC 0,018 % + 61 µV 2 kHz až 20 kHz 0,1 V až 1 V CMC 0,030 % + 0,10 mV 20 kHz až 100 kHz 0,1 V až 1 V CMC 0,072 % + 0,50 mV 100 kHz až 1 MHz 0,1 V až 1 V CMC 1,2 % + 25 mV 10 Hz až 40 Hz 1 V až 10 V CMC 0,048 % + 2,3 mV 40 Hz až 200 Hz 1 V až 10 V CMC 0,021 % + 0,61 mV 200 Hz až 2 kHz 1 V až 10 V CMC 0,018 % + 0,61 mV 2 kHz až 20 kHz 1 V až 10 V CMC 0,030 % + 1,0 mV 20 kHz až 100 kHz 1 V až 10 V CMC 0,072 % + 5,0 mV 100 kHz až 200 kHz 1 V až 10 V CMC 1,2 % + 0,25 V 10 Hz až 40 Hz 10 V až 100 V CMC 0,060 % + 23 mV 40 Hz až 200 Hz 10 V až 100 V CMC 0,024 % + 10 mV 200 Hz až 2 kHz 10 V až 100 V CMC 0,022 % + 7,1 mV 2 kHz až 20 kHz 10 V až 100 V CMC 0,033 % + 11 mV 20 kHz až 50 kHz 10 V až 100 V CMC 0,11 % + 62 mV 10 Hz až 40 Hz 100 V až 1000 V CMC 0,060 % + 0,16 V 40 Hz až 200 Hz 100 V až 1000 V CMC 0,021 % + 0,10 V 200 Hz až 2 kHz 100 V až 1000 V CMC 0,022 % + 0,10 V 2 kHz až 10 kHz 100 V až 1000 V CMC 0,037 % + 0,11 V KP-PB-112 Napiecie przemienne / zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 10 Hz do 40 Hz od 0 mV do 100 mV CMC 0,061 % + 19 µV 40 Hz do 200 Hz od 0 mV do 100 mV CMC 0,027 % + 15 µV 200 Hz do 2 kHz od 0 mV do 100 mV CMC 0,023 % + 13 µV 2 kHz do 20 kHz od 0 mV do 100 mV CMC 0,032 % + 14 µV 20 kHz do 100 kHz od 0 mV do 100 mV CMC 0,081 % + 51 µV 10 Hz do 40 Hz od 0,1 V do 1 V CMC 0,048 % + 0,24 mV 40 Hz do 200 Hz od 0,1 V do 1 V CMC 0,023 % + 61 µV 200 Hz do 2 kHz od 0,1 V do 1 V CMC 0,018 % + 61 µV 2 kHz do 20 kHz od 0,1 V do 1 V CMC 0,030 % + 0,10 mV 20 kHz do 100 kHz od 0,1 V do 1 V CMC 0,072 % + 0,50 mV 100 kHz do 1 MHz od 0,1 V do 1 V CMC 1,2 % + 25 mV 10 Hz do 40 Hz od 1 V do 10 V CMC 0,048 % + 2,3 mV 40 Hz do 200 Hz od 1 V do 10 V CMC 0,021 % + 0,61 mV 200 Hz do 2 kHz od 1 V do 10 V CMC 0,018 % + 0,61 mV 2 kHz do 20 kHz od 1 V do 10 V CMC 0,030 % + 1,0 mV 20 kHz do 100 kHz od 1 V do 10 V CMC 0,072 % + 5,0 mV 100 kHz do 200 kHz od 1 V do 10 V CMC 1,2 % + 0,25 V 10 Hz do 40 Hz od 10 V do 100 V CMC 0,060 % + 23 mV 40 Hz do 200 Hz od 10 V do 100 V CMC 0,024 % + 10 mV 200 Hz do 2 kHz od 10 V do 100 V CMC 0,022 % + 7,1 mV 2 kHz do 20 kHz od 10 V do 100 V CMC 0,033 % + 11 mV 20 kHz do 50 kHz od 10 V do 100 V CMC 0,11 % + 62 mV 10 Hz do 40 Hz od 100 V do 1000 V CMC 0,060 % + 0,16 V 40 Hz do 200 Hz od 100 V do 1000 V CMC 0,021 % + 0,10 V 200 Hz do 2 kHz od 100 V do 1000 V CMC 0,022 % + 0,10 V 2 kHz do 10 kHz od 100 V do 1000 V CMC 0,037 % + 0,11 V Stridave napeti / Zdroje stridaveho napeti Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 10 Hz az 40 Hz 0 mV az 100 mV CMC 0,061 % + 19 µV 40 Hz az 200 Hz 0 mV az 100 mV CMC 0,027 % + 15 µV 200 Hz az 2 kHz 0 mV az 100 mV CMC 0,023 % + 13 µV 2 kHz az 20 kHz 0 mV az 100 mV CMC 0,032 % + 14 µV 20 kHz az 100 kHz 0 mV az 100 mV CMC 0,081 % + 51 µV 10 Hz az 40 Hz 0,1 V az 1 V CMC 0,048 % + 0,24 mV 40 Hz az 200 Hz 0,1 V az 1 V CMC 0,023 % + 61 µV 200 Hz az 2 kHz 0,1 V az 1 V CMC 0,018 % + 61 µV 2 kHz az 20 kHz 0,1 V az 1 V CMC 0,030 % + 0,10 mV 20 kHz az 100 kHz 0,1 V az 1 V CMC 0,072 % + 0,50 mV 100 kHz az 1 MHz 0,1 V az 1 V CMC 1,2 % + 25 mV 10 Hz az 40 Hz 1 V az 10 V CMC 0,048 % + 2,3 mV 40 Hz az 200 Hz 1 V az 10 V CMC 0,021 % + 0,61 mV 200 Hz az 2 kHz 1 V az 10 V CMC 0,018 % + 0,61 mV 2 kHz az 20 kHz 1 V az 10 V CMC 0,030 % + 1,0 mV 20 kHz az 100 kHz 1 V az 10 V CMC 0,072 % + 5,0 mV 100 kHz az 200 kHz 1 V az 10 V CMC 1,2 % + 0,25 V 10 Hz az 40 Hz 10 V az 100 V CMC 0,060 % + 23 mV 40 Hz az 200 Hz 10 V az 100 V CMC 0,024 % + 10 mV 200 Hz az 2 kHz 10 V az 100 V CMC 0,022 % + 7,1 mV 2 kHz az 20 kHz 10 V az 100 V CMC 0,033 % + 11 mV 20 kHz az 50 kHz 10 V az 100 V CMC 0,11 % + 62 mV 10 Hz az 40 Hz 100 V az 1000 V CMC 0,060 % + 0,16 V 40 Hz az 200 Hz 100 V az 1000 V CMC 0,021 % + 0,10 V 200 Hz az 2 kHz 100 V az 1000 V CMC 0,022 % + 0,10 V 2 kHz az 10 kHz 100 V az 1000 V CMC 0,037 % + 0,11 V KP-PB-112","search_en":"AC voltage / AC voltage sources Calibration – electrical quantities Direct measurement by a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement by a reference multimeter 10 Hz to 40 Hz 40 Hz to 200 Hz 200 Hz to 2 kHz 2 kHz to 20 kHz 20 kHz to 100 kHz 10 Hz to 40 Hz 40 Hz to 200 Hz 200 Hz to 2 kHz 2 kHz to 20 kHz 20 kHz to 100 kHz 100 kHz to 1 MHz 10 Hz to 40 Hz 40 Hz to 200 Hz 200 Hz to 2 kHz 2 kHz to 20 kHz 20 kHz to 100 kHz 100 kHz to 200 kHz 10 Hz to 40 Hz 40 Hz to 200 Hz 200 Hz to 2 kHz 2 kHz to 20 kHz 20 kHz to 50 kHz 10 Hz to 40 Hz 40 Hz to 200 Hz 200 Hz to 2 kHz 2 kHz to 10 kHz KP-PB-112","search_zh":"交流电压 / 交流电压源 校准 – 电学量 用标准万用表直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用标准万用表直接测量 10 Hz 至 40 Hz 40 Hz 至 200 Hz 200 Hz 至 2 kHz 2 kHz 至 20 kHz 20 kHz 至 100 kHz 10 Hz 至 40 Hz 40 Hz 至 200 Hz 200 Hz 至 2 kHz 2 kHz 至 20 kHz 20 kHz 至 100 kHz 100 kHz 至 1 MHz 10 Hz 至 40 Hz 40 Hz 至 200 Hz 200 Hz 至 2 kHz 2 kHz 至 20 kHz 20 kHz 至 100 kHz 100 kHz 至 200 kHz 10 Hz 至 40 Hz 40 Hz 至 200 Hz 200 Hz 至 2 kHz 2 kHz 至 20 kHz 20 kHz 至 50 kHz 10 Hz 至 40 Hz 40 Hz 至 200 Hz 200 Hz 至 2 kHz 2 kHz 至 10 kHz KP-PB-112","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"10 Hz bis 40 Hz","range":"von 0 mV bis 100 mV","cmc":"0,061 % + 19 µV"},{"name":"40 Hz bis 200 Hz","range":"von 0 mV bis 100 mV","cmc":"0,027 % + 15 µV"},{"name":"200 Hz bis 2 kHz","range":"von 0 mV bis 100 mV","cmc":"0,023 % + 13 µV"},{"name":"2 kHz bis 20 kHz","range":"von 0 mV bis 100 mV","cmc":"0,032 % + 14 µV"},{"name":"20 kHz bis 100 kHz","range":"von 0 mV bis 100 mV","cmc":"0,081 % + 51 µV"},{"name":"10 Hz bis 40 Hz","range":"von 0,1 V bis 1 V","cmc":"0,048 % + 0,24 mV"},{"name":"40 Hz bis 200 Hz","range":"von 0,1 V bis 1 V","cmc":"0,023 % + 61 µV"},{"name":"200 Hz bis 2 kHz","range":"von 0,1 V bis 1 V","cmc":"0,018 % + 61 µV"},{"name":"2 kHz bis 20 kHz","range":"von 0,1 V bis 1 V","cmc":"0,030 % + 0,10 mV"},{"name":"20 kHz bis 100 kHz","range":"von 0,1 V bis 1 V","cmc":"0,072 % + 0,50 mV"},{"name":"100 kHz bis 1 MHz","range":"von 0,1 V bis 1 V","cmc":"1,2 % + 25 mV"},{"name":"10 Hz bis 40 Hz","range":"von 1 V bis 10 V","cmc":"0,048 % + 2,3 mV"},{"name":"40 Hz bis 200 Hz","range":"von 1 V bis 10 V","cmc":"0,021 % + 0,61 mV"},{"name":"200 Hz bis 2 kHz","range":"von 1 V bis 10 V","cmc":"0,018 % + 0,61 mV"},{"name":"2 kHz bis 20 kHz","range":"von 1 V bis 10 V","cmc":"0,030 % + 1,0 mV"},{"name":"20 kHz bis 100 kHz","range":"von 1 V bis 10 V","cmc":"0,072 % + 5,0 mV"},{"name":"100 kHz bis 200 kHz","range":"von 1 V bis 10 V","cmc":"1,2 % + 0,25 V"},{"name":"10 Hz bis 40 Hz","range":"von 10 V bis 100 V","cmc":"0,060 % + 23 mV"},{"name":"40 Hz bis 200 Hz","range":"von 10 V bis 100 V","cmc":"0,024 % + 10 mV"},{"name":"200 Hz bis 2 kHz","range":"von 10 V bis 100 V","cmc":"0,022 % + 7,1 mV"},{"name":"2 kHz bis 20 kHz","range":"von 10 V bis 100 V","cmc":"0,033 % + 11 mV"},{"name":"20 kHz bis 50 kHz","range":"von 10 V bis 100 V","cmc":"0,11 % + 62 mV"},{"name":"10 Hz bis 40 Hz","range":"von 100 V bis 1000 V","cmc":"0,060 % + 0,16 V"},{"name":"40 Hz bis 200 Hz","range":"von 100 V bis 1000 V","cmc":"0,021 % + 0,10 V"},{"name":"200 Hz bis 2 kHz","range":"von 100 V bis 1000 V","cmc":"0,022 % + 0,10 V"},{"name":"2 kHz bis 10 kHz","range":"von 100 V bis 1000 V","cmc":"0,037 % + 0,11 V"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Wechselspannung / Wechselspannungsquellen Kalibrierung – elektrische Größen Direkte Messung mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung mit einem Referenzmultimeter 10 Hz bis 40 Hz 40 Hz bis 200 Hz 200 Hz bis 2 kHz 2 kHz bis 20 kHz 20 kHz bis 100 kHz 10 Hz bis 40 Hz 40 Hz bis 200 Hz 200 Hz bis 2 kHz 2 kHz bis 20 kHz 20 kHz bis 100 kHz 100 kHz bis 1 MHz 10 Hz bis 40 Hz 40 Hz bis 200 Hz 200 Hz bis 2 kHz 2 kHz bis 20 kHz 20 kHz bis 100 kHz 100 kHz bis 200 kHz 10 Hz bis 40 Hz 40 Hz bis 200 Hz 200 Hz bis 2 kHz 2 kHz bis 20 kHz 20 kHz bis 50 kHz 10 Hz bis 40 Hz 40 Hz bis 200 Hz 200 Hz bis 2 kHz 2 kHz bis 10 kHz KP-PB-112","technique_de":"Direkte Messung mit einem Referenzmultimeter","techniques_de":["Direkte Messung mit einem Referenzmultimeter"],"test_object_de":"Wechselspannung / Wechselspannungsquellen"},{"_id":"ded93837c5edc69a8019f982","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / źródła napięcia przemiennego","test_object_en":"AC voltage / AC voltage sources","test_object_zh":"交流电压 / 交流电压源","test_object_cs":"Střídavé napětí / Zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 1 kV do 10 kV","cmc":"2,2 %"}],"parameters_en":[{"name":"50 Hz","range":"1 kV to 10 kV","cmc":"2,2 %"}],"parameters_zh":[{"name":"50 Hz","range":"1 kV 至 10 kV","cmc":"2,2 %"}],"parameters_cs":[{"name":"50 Hz","range":"1 kV až 10 kV","cmc":"2,2 %"}],"technique":"Pomiar multimetrem wzorcowym z sondą wysokonapięciową","technique_en":"Measurement with a reference multimeter with HV probe","technique_zh":"用带高压探头的标准万用表测量","technique_cs":"Měření etalonovým multimetrem s VN sondou","techniques":["Pomiar multimetrem wzorcowym z sondą wysokonapięciową"],"techniques_en":["Measurement with a reference multimeter with HV probe"],"techniques_zh":["用带高压探头的标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem s VN sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 1 kV do 10 kV CMC 2,2 %\nPomiar multimetrem wzorcowym z sondą wysokonapięciową","reference":"KP-PB-112","norm_bases":["KP-PB-112"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym z sondą wysokonapięciową 50 Hz od 1 kV do 10 kV CMC 2,2 % Střídavé napětí / Zdroje střídavého napětí Kalibrace – elektrické veličiny Měření etalonovým multimetrem s VN sondou 50 Hz 1 kV až 10 kV CMC 2,2 % KP-PB-112 Napiecie przemienne / zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym z sonda wysokonapieciowa 50 Hz od 1 kV do 10 kV CMC 2,2 % Stridave napeti / Zdroje stridaveho napeti Kalibrace – elektricke veliciny Mereni etalonovym multimetrem s VN sondou 50 Hz 1 kV az 10 kV CMC 2,2 % KP-PB-112","search_en":"AC voltage / AC voltage sources Calibration – electrical quantities Measurement with a reference multimeter with HV probe Uherský Brod II CMC for the field of measured quantity: Electrical quantities Measurement with a reference multimeter with HV probe 50 Hz KP-PB-112","search_zh":"交流电压 / 交流电压源 校准 – 电学量 用带高压探头的标准万用表测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用带高压探头的标准万用表测量 50 Hz KP-PB-112","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"50 Hz","range":"von 1 kV bis 10 kV","cmc":"2,2 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Wechselspannung / Wechselspannungsquellen Kalibrierung – elektrische Größen Messung mit einem Referenzmultimeter mit Hochspannungstastkopf Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Messung mit einem Referenzmultimeter mit Hochspannungstastkopf 50 Hz KP-PB-112","technique_de":"Messung mit einem Referenzmultimeter mit Hochspannungstastkopf","techniques_de":["Messung mit einem Referenzmultimeter mit Hochspannungstastkopf"],"test_object_de":"Wechselspannung / Wechselspannungsquellen"},{"_id":"67b6f3e6ad146891b21c7706","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / przyrządy do pomiaru napięcia przemiennego","test_object_en":"AC voltage / AC voltage meters","test_object_zh":"交流电压 / 交流电压测量仪器","test_object_cs":"Střídavé napětí / Měřidla střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 45 Hz","range":"od 0 mV do 202 mV","cmc":"0,071 % + 24 µV"},{"name":"45 Hz do 1 kHz","range":"od 0 mV do 202 mV","cmc":"0,018 % + 24 µV"},{"name":"1 kHz do 20 kHz","range":"od 0 mV do 202 mV","cmc":"0,020 % + 33 µV"},{"name":"20 kHz do 100 kHz","range":"od 0 mV do 202 mV","cmc":"0,13 % + 56 µV"},{"name":"100 kHz do 500 kHz","range":"od 0 mV do 202 mV","cmc":"0,35 % + 0,10 mV"},{"name":"10 Hz do 45 Hz","range":"od 0,202 V do 2,02 V","cmc":"0,053 % + 0,21 mV"},{"name":"45 Hz do 1 kHz","range":"od 0,202 V do 2,02 V","cmc":"0,019 % + 0,12 mV"},{"name":"1 kHz do 20 kHz","range":"od 0,202 V do 2,02 V","cmc":"0,020 % + 0,21 mV"},{"name":"20 kHz do 100 kHz","range":"od 0,202 V do 2,02 V","cmc":"0,067 % + 0,30 mV"},{"name":"100 kHz do 500 kHz","range":"od 0,202 V do 2,02 V","cmc":"0,29 % + 0,46 mV"},{"name":"10 Hz do 45 Hz","range":"od 2,02 V do 20,2 V","cmc":"0,050 % + 2,0 mV"},{"name":"45 Hz do 1 kHz","range":"od 2,02 V do 20,2 V","cmc":"0,017 % + 1,3 mV"},{"name":"1 kHz do 20 kHz","range":"od 2,02 V do 20,2 V","cmc":"0,021 % + 1,8 mV"},{"name":"20 kHz do 100 kHz","range":"od 2,02 V do 20,2 V","cmc":"0,083 % + 3,8 mV"},{"name":"30 Hz do 45 Hz","range":"od 20,2 V do 202 V","cmc":"0,050 % + 24 mV"},{"name":"45 Hz do 1 kHz","range":"od 20,2 V do 202 V","cmc":"0,017 % + 13 mV"},{"name":"1 kHz do 10 kHz","range":"od 20,2 V do 202 V","cmc":"0,021 % + 19 mV"},{"name":"10 kHz do 40 kHz","range":"od 20,2 V do 202 V","cmc":"0,035 % + 31 mV"},{"name":"30 Hz do 45 Hz","range":"od 202 V do 1020 V","cmc":"0,060 % + 0,21 V"},{"name":"45 Hz do 1 kHz","range":"od 202 V do 1020 V","cmc":"0,024 % + 0,08 V"},{"name":"1 kHz do 10 kHz","range":"od 202 V do 1020 V","cmc":"0,039 % + 0,13 V"}],"parameters_en":[{"name":"10 Hz to 45 Hz","range":"0 mV to 202 mV","cmc":"0,071 % + 24 µV"},{"name":"45 Hz to 1 kHz","range":"0 mV to 202 mV","cmc":"0,018 % + 24 µV"},{"name":"1 kHz to 20 kHz","range":"0 mV to 202 mV","cmc":"0,020 % + 33 µV"},{"name":"20 kHz to 100 kHz","range":"0 mV to 202 mV","cmc":"0,13 % + 56 µV"},{"name":"100 kHz to 500 kHz","range":"0 mV to 202 mV","cmc":"0,35 % + 0,10 mV"},{"name":"10 Hz to 45 Hz","range":"0,202 V to 2,02 V","cmc":"0,053 % + 0,21 mV"},{"name":"45 Hz to 1 kHz","range":"0,202 V to 2,02 V","cmc":"0,019 % + 0,12 mV"},{"name":"1 kHz to 20 kHz","range":"0,202 V to 2,02 V","cmc":"0,020 % + 0,21 mV"},{"name":"20 kHz to 100 kHz","range":"0,202 V to 2,02 V","cmc":"0,067 % + 0,30 mV"},{"name":"100 kHz to 500 kHz","range":"0,202 V to 2,02 V","cmc":"0,29 % + 0,46 mV"},{"name":"10 Hz to 45 Hz","range":"2,02 V to 20,2 V","cmc":"0,050 % + 2,0 mV"},{"name":"45 Hz to 1 kHz","range":"2,02 V to 20,2 V","cmc":"0,017 % + 1,3 mV"},{"name":"1 kHz to 20 kHz","range":"2,02 V to 20,2 V","cmc":"0,021 % + 1,8 mV"},{"name":"20 kHz to 100 kHz","range":"2,02 V to 20,2 V","cmc":"0,083 % + 3,8 mV"},{"name":"30 Hz to 45 Hz","range":"20,2 V to 202 V","cmc":"0,050 % + 24 mV"},{"name":"45 Hz to 1 kHz","range":"20,2 V to 202 V","cmc":"0,017 % + 13 mV"},{"name":"1 kHz to 10 kHz","range":"20,2 V to 202 V","cmc":"0,021 % + 19 mV"},{"name":"10 kHz to 40 kHz","range":"20,2 V to 202 V","cmc":"0,035 % + 31 mV"},{"name":"30 Hz to 45 Hz","range":"202 V to 1020 V","cmc":"0,060 % + 0,21 V"},{"name":"45 Hz to 1 kHz","range":"202 V to 1020 V","cmc":"0,024 % + 0,08 V"},{"name":"1 kHz to 10 kHz","range":"202 V to 1020 V","cmc":"0,039 % + 0,13 V"}],"parameters_zh":[{"name":"10 Hz 至 45 Hz","range":"0 mV 至 202 mV","cmc":"0,071 % + 24 µV"},{"name":"45 Hz 至 1 kHz","range":"0 mV 至 202 mV","cmc":"0,018 % + 24 µV"},{"name":"1 kHz 至 20 kHz","range":"0 mV 至 202 mV","cmc":"0,020 % + 33 µV"},{"name":"20 kHz 至 100 kHz","range":"0 mV 至 202 mV","cmc":"0,13 % + 56 µV"},{"name":"100 kHz 至 500 kHz","range":"0 mV 至 202 mV","cmc":"0,35 % + 0,10 mV"},{"name":"10 Hz 至 45 Hz","range":"0,202 V 至 2,02 V","cmc":"0,053 % + 0,21 mV"},{"name":"45 Hz 至 1 kHz","range":"0,202 V 至 2,02 V","cmc":"0,019 % + 0,12 mV"},{"name":"1 kHz 至 20 kHz","range":"0,202 V 至 2,02 V","cmc":"0,020 % + 0,21 mV"},{"name":"20 kHz 至 100 kHz","range":"0,202 V 至 2,02 V","cmc":"0,067 % + 0,30 mV"},{"name":"100 kHz 至 500 kHz","range":"0,202 V 至 2,02 V","cmc":"0,29 % + 0,46 mV"},{"name":"10 Hz 至 45 Hz","range":"2,02 V 至 20,2 V","cmc":"0,050 % + 2,0 mV"},{"name":"45 Hz 至 1 kHz","range":"2,02 V 至 20,2 V","cmc":"0,017 % + 1,3 mV"},{"name":"1 kHz 至 20 kHz","range":"2,02 V 至 20,2 V","cmc":"0,021 % + 1,8 mV"},{"name":"20 kHz 至 100 kHz","range":"2,02 V 至 20,2 V","cmc":"0,083 % + 3,8 mV"},{"name":"30 Hz 至 45 Hz","range":"20,2 V 至 202 V","cmc":"0,050 % + 24 mV"},{"name":"45 Hz 至 1 kHz","range":"20,2 V 至 202 V","cmc":"0,017 % + 13 mV"},{"name":"1 kHz 至 10 kHz","range":"20,2 V 至 202 V","cmc":"0,021 % + 19 mV"},{"name":"10 kHz 至 40 kHz","range":"20,2 V 至 202 V","cmc":"0,035 % + 31 mV"},{"name":"30 Hz 至 45 Hz","range":"202 V 至 1020 V","cmc":"0,060 % + 0,21 V"},{"name":"45 Hz 至 1 kHz","range":"202 V 至 1020 V","cmc":"0,024 % + 0,08 V"},{"name":"1 kHz 至 10 kHz","range":"202 V 至 1020 V","cmc":"0,039 % + 0,13 V"}],"parameters_cs":[{"name":"10 Hz až 45 Hz","range":"0 mV až 202 mV","cmc":"0,071 % + 24 µV"},{"name":"45 Hz až 1 kHz","range":"0 mV až 202 mV","cmc":"0,018 % + 24 µV"},{"name":"1 kHz až 20 kHz","range":"0 mV až 202 mV","cmc":"0,020 % + 33 µV"},{"name":"20 kHz až 100 kHz","range":"0 mV až 202 mV","cmc":"0,13 % + 56 µV"},{"name":"100 kHz až 500 kHz","range":"0 mV až 202 mV","cmc":"0,35 % + 0,10 mV"},{"name":"10 Hz až 45 Hz","range":"0,202 V až 2,02 V","cmc":"0,053 % + 0,21 mV"},{"name":"45 Hz až 1 kHz","range":"0,202 V až 2,02 V","cmc":"0,019 % + 0,12 mV"},{"name":"1 kHz až 20 kHz","range":"0,202 V až 2,02 V","cmc":"0,020 % + 0,21 mV"},{"name":"20 kHz až 100 kHz","range":"0,202 V až 2,02 V","cmc":"0,067 % + 0,30 mV"},{"name":"100 kHz až 500 kHz","range":"0,202 V až 2,02 V","cmc":"0,29 % + 0,46 mV"},{"name":"10 Hz až 45 Hz","range":"2,02 V až 20,2 V","cmc":"0,050 % + 2,0 mV"},{"name":"45 Hz až 1 kHz","range":"2,02 V až 20,2 V","cmc":"0,017 % + 1,3 mV"},{"name":"1 kHz až 20 kHz","range":"2,02 V až 20,2 V","cmc":"0,021 % + 1,8 mV"},{"name":"20 kHz až 100 kHz","range":"2,02 V až 20,2 V","cmc":"0,083 % + 3,8 mV"},{"name":"30 Hz až 45 Hz","range":"20,2 V až 202 V","cmc":"0,050 % + 24 mV"},{"name":"45 Hz až 1 kHz","range":"20,2 V až 202 V","cmc":"0,017 % + 13 mV"},{"name":"1 kHz až 10 kHz","range":"20,2 V až 202 V","cmc":"0,021 % + 19 mV"},{"name":"10 kHz až 40 kHz","range":"20,2 V až 202 V","cmc":"0,035 % + 31 mV"},{"name":"30 Hz až 45 Hz","range":"202 V až 1020 V","cmc":"0,060 % + 0,21 V"},{"name":"45 Hz až 1 kHz","range":"202 V až 1020 V","cmc":"0,024 % + 0,08 V"},{"name":"1 kHz až 10 kHz","range":"202 V až 1020 V","cmc":"0,039 % + 0,13 V"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym","technique_en":"Direct measurement on a reference calibrator or comparison with a reference multimeter","technique_zh":"在标准校准器上直接测量或与标准万用表比较","technique_cs":"Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement on a reference calibrator or comparison with a reference multimeter"],"techniques_zh":["在标准校准器上直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 45 Hz od 0 mV do 202 mV CMC 0,071 % + 24 µV\n45 Hz do 1 kHz od 0 mV do 202 mV CMC 0,018 % + 24 µV\n1 kHz do 20 kHz od 0 mV do 202 mV CMC 0,020 % + 33 µV\n20 kHz do 100 kHz od 0 mV do 202 mV CMC 0,13 % + 56 µV\n100 kHz do 500 kHz od 0 mV do 202 mV CMC 0,35 % + 0,10 mV\n10 Hz do 45 Hz od 0,202 V do 2,02 V CMC 0,053 % + 0,21 mV\n45 Hz do 1 kHz od 0,202 V do 2,02 V CMC 0,019 % + 0,12 mV\n1 kHz do 20 kHz od 0,202 V do 2,02 V CMC 0,020 % + 0,21 mV\n20 kHz do 100 kHz od 0,202 V do 2,02 V CMC 0,067 % + 0,30 mV\n100 kHz do 500 kHz od 0,202 V do 2,02 V CMC 0,29 % + 0,46 mV\n10 Hz do 45 Hz od 2,02 V do 20,2 V CMC 0,050 % + 2,0 mV\n45 Hz do 1 kHz od 2,02 V do 20,2 V CMC 0,017 % + 1,3 mV\n1 kHz do 20 kHz od 2,02 V do 20,2 V CMC 0,021 % + 1,8 mV\n20 kHz do 100 kHz od 2,02 V do 20,2 V CMC 0,083 % + 3,8 mV\n30 Hz do 45 Hz od 20,2 V do 202 V CMC 0,050 % + 24 mV\n45 Hz do 1 kHz od 20,2 V do 202 V CMC 0,017 % + 13 mV\n1 kHz do 10 kHz od 20,2 V do 202 V CMC 0,021 % + 19 mV\n10 kHz do 40 kHz od 20,2 V do 202 V CMC 0,035 % + 31 mV\n30 Hz do 45 Hz od 202 V do 1020 V CMC 0,060 % + 0,21 V\n45 Hz do 1 kHz od 202 V do 1020 V CMC 0,024 % + 0,08 V\n1 kHz do 10 kHz od 202 V do 1020 V CMC 0,039 % + 0,13 V\nPomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym","reference":"KP-PB-112","norm_bases":["KP-PB-112"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / przyrządy do pomiaru napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym 10 Hz do 45 Hz od 0 mV do 202 mV CMC 0,071 % + 24 µV 45 Hz do 1 kHz od 0 mV do 202 mV CMC 0,018 % + 24 µV 1 kHz do 20 kHz od 0 mV do 202 mV CMC 0,020 % + 33 µV 20 kHz do 100 kHz od 0 mV do 202 mV CMC 0,13 % + 56 µV 100 kHz do 500 kHz od 0 mV do 202 mV CMC 0,35 % + 0,10 mV 10 Hz do 45 Hz od 0,202 V do 2,02 V CMC 0,053 % + 0,21 mV 45 Hz do 1 kHz od 0,202 V do 2,02 V CMC 0,019 % + 0,12 mV 1 kHz do 20 kHz od 0,202 V do 2,02 V CMC 0,020 % + 0,21 mV 20 kHz do 100 kHz od 0,202 V do 2,02 V CMC 0,067 % + 0,30 mV 100 kHz do 500 kHz od 0,202 V do 2,02 V CMC 0,29 % + 0,46 mV 10 Hz do 45 Hz od 2,02 V do 20,2 V CMC 0,050 % + 2,0 mV 45 Hz do 1 kHz od 2,02 V do 20,2 V CMC 0,017 % + 1,3 mV 1 kHz do 20 kHz od 2,02 V do 20,2 V CMC 0,021 % + 1,8 mV 20 kHz do 100 kHz od 2,02 V do 20,2 V CMC 0,083 % + 3,8 mV 30 Hz do 45 Hz od 20,2 V do 202 V CMC 0,050 % + 24 mV 45 Hz do 1 kHz od 20,2 V do 202 V CMC 0,017 % + 13 mV 1 kHz do 10 kHz od 20,2 V do 202 V CMC 0,021 % + 19 mV 10 kHz do 40 kHz od 20,2 V do 202 V CMC 0,035 % + 31 mV 30 Hz do 45 Hz od 202 V do 1020 V CMC 0,060 % + 0,21 V 45 Hz do 1 kHz od 202 V do 1020 V CMC 0,024 % + 0,08 V 1 kHz do 10 kHz od 202 V do 1020 V CMC 0,039 % + 0,13 V Střídavé napětí / Měřidla střídavého napětí Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem 10 Hz až 45 Hz 0 mV až 202 mV CMC 0,071 % + 24 µV 45 Hz až 1 kHz 0 mV až 202 mV CMC 0,018 % + 24 µV 1 kHz až 20 kHz 0 mV až 202 mV CMC 0,020 % + 33 µV 20 kHz až 100 kHz 0 mV až 202 mV CMC 0,13 % + 56 µV 100 kHz až 500 kHz 0 mV až 202 mV CMC 0,35 % + 0,10 mV 10 Hz až 45 Hz 0,202 V až 2,02 V CMC 0,053 % + 0,21 mV 45 Hz až 1 kHz 0,202 V až 2,02 V CMC 0,019 % + 0,12 mV 1 kHz až 20 kHz 0,202 V až 2,02 V CMC 0,020 % + 0,21 mV 20 kHz až 100 kHz 0,202 V až 2,02 V CMC 0,067 % + 0,30 mV 100 kHz až 500 kHz 0,202 V až 2,02 V CMC 0,29 % + 0,46 mV 10 Hz až 45 Hz 2,02 V až 20,2 V CMC 0,050 % + 2,0 mV 45 Hz až 1 kHz 2,02 V až 20,2 V CMC 0,017 % + 1,3 mV 1 kHz až 20 kHz 2,02 V až 20,2 V CMC 0,021 % + 1,8 mV 20 kHz až 100 kHz 2,02 V až 20,2 V CMC 0,083 % + 3,8 mV 30 Hz až 45 Hz 20,2 V až 202 V CMC 0,050 % + 24 mV 45 Hz až 1 kHz 20,2 V až 202 V CMC 0,017 % + 13 mV 1 kHz až 10 kHz 20,2 V až 202 V CMC 0,021 % + 19 mV 10 kHz až 40 kHz 20,2 V až 202 V CMC 0,035 % + 31 mV 30 Hz až 45 Hz 202 V až 1020 V CMC 0,060 % + 0,21 V 45 Hz až 1 kHz 202 V až 1020 V CMC 0,024 % + 0,08 V 1 kHz až 10 kHz 202 V až 1020 V CMC 0,039 % + 0,13 V KP-PB-112 Napiecie przemienne / przyrzady do pomiaru napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym lub porownanie z multimetrem wzorcowym 10 Hz do 45 Hz od 0 mV do 202 mV CMC 0,071 % + 24 µV 45 Hz do 1 kHz od 0 mV do 202 mV CMC 0,018 % + 24 µV 1 kHz do 20 kHz od 0 mV do 202 mV CMC 0,020 % + 33 µV 20 kHz do 100 kHz od 0 mV do 202 mV CMC 0,13 % + 56 µV 100 kHz do 500 kHz od 0 mV do 202 mV CMC 0,35 % + 0,10 mV 10 Hz do 45 Hz od 0,202 V do 2,02 V CMC 0,053 % + 0,21 mV 45 Hz do 1 kHz od 0,202 V do 2,02 V CMC 0,019 % + 0,12 mV 1 kHz do 20 kHz od 0,202 V do 2,02 V CMC 0,020 % + 0,21 mV 20 kHz do 100 kHz od 0,202 V do 2,02 V CMC 0,067 % + 0,30 mV 100 kHz do 500 kHz od 0,202 V do 2,02 V CMC 0,29 % + 0,46 mV 10 Hz do 45 Hz od 2,02 V do 20,2 V CMC 0,050 % + 2,0 mV 45 Hz do 1 kHz od 2,02 V do 20,2 V CMC 0,017 % + 1,3 mV 1 kHz do 20 kHz od 2,02 V do 20,2 V CMC 0,021 % + 1,8 mV 20 kHz do 100 kHz od 2,02 V do 20,2 V CMC 0,083 % + 3,8 mV 30 Hz do 45 Hz od 20,2 V do 202 V CMC 0,050 % + 24 mV 45 Hz do 1 kHz od 20,2 V do 202 V CMC 0,017 % + 13 mV 1 kHz do 10 kHz od 20,2 V do 202 V CMC 0,021 % + 19 mV 10 kHz do 40 kHz od 20,2 V do 202 V CMC 0,035 % + 31 mV 30 Hz do 45 Hz od 202 V do 1020 V CMC 0,060 % + 0,21 V 45 Hz do 1 kHz od 202 V do 1020 V CMC 0,024 % + 0,08 V 1 kHz do 10 kHz od 202 V do 1020 V CMC 0,039 % + 0,13 V Stridave napeti / Meridla stridaveho napeti Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru nebo porovnani s etalonovym multimetrem 10 Hz az 45 Hz 0 mV az 202 mV CMC 0,071 % + 24 µV 45 Hz az 1 kHz 0 mV az 202 mV CMC 0,018 % + 24 µV 1 kHz az 20 kHz 0 mV az 202 mV CMC 0,020 % + 33 µV 20 kHz az 100 kHz 0 mV az 202 mV CMC 0,13 % + 56 µV 100 kHz az 500 kHz 0 mV az 202 mV CMC 0,35 % + 0,10 mV 10 Hz az 45 Hz 0,202 V az 2,02 V CMC 0,053 % + 0,21 mV 45 Hz az 1 kHz 0,202 V az 2,02 V CMC 0,019 % + 0,12 mV 1 kHz az 20 kHz 0,202 V az 2,02 V CMC 0,020 % + 0,21 mV 20 kHz az 100 kHz 0,202 V az 2,02 V CMC 0,067 % + 0,30 mV 100 kHz az 500 kHz 0,202 V az 2,02 V CMC 0,29 % + 0,46 mV 10 Hz az 45 Hz 2,02 V az 20,2 V CMC 0,050 % + 2,0 mV 45 Hz az 1 kHz 2,02 V az 20,2 V CMC 0,017 % + 1,3 mV 1 kHz az 20 kHz 2,02 V az 20,2 V CMC 0,021 % + 1,8 mV 20 kHz az 100 kHz 2,02 V az 20,2 V CMC 0,083 % + 3,8 mV 30 Hz az 45 Hz 20,2 V az 202 V CMC 0,050 % + 24 mV 45 Hz az 1 kHz 20,2 V az 202 V CMC 0,017 % + 13 mV 1 kHz az 10 kHz 20,2 V az 202 V CMC 0,021 % + 19 mV 10 kHz az 40 kHz 20,2 V az 202 V CMC 0,035 % + 31 mV 30 Hz az 45 Hz 202 V az 1020 V CMC 0,060 % + 0,21 V 45 Hz az 1 kHz 202 V az 1020 V CMC 0,024 % + 0,08 V 1 kHz az 10 kHz 202 V az 1020 V CMC 0,039 % + 0,13 V KP-PB-112","search_en":"AC voltage / AC voltage meters Calibration – electrical quantities Direct measurement on a reference calibrator or comparison with a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator or comparison with a reference multimeter 10 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 20 kHz 20 kHz to 100 kHz 100 kHz to 500 kHz 10 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 20 kHz 20 kHz to 100 kHz 100 kHz to 500 kHz 10 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 20 kHz 20 kHz to 100 kHz 30 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 10 kHz 10 kHz to 40 kHz 30 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 10 kHz KP-PB-112","search_zh":"交流电压 / 交流电压测量仪器 校准 – 电学量 在标准校准器上直接测量或与标准万用表比较 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在标准校准器上直接测量或与标准万用表比较 10 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 20 kHz 20 kHz 至 100 kHz 100 kHz 至 500 kHz 10 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 20 kHz 20 kHz 至 100 kHz 100 kHz 至 500 kHz 10 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 20 kHz 20 kHz 至 100 kHz 30 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 10 kHz 10 kHz 至 40 kHz 30 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 10 kHz KP-PB-112","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"10 Hz bis 45 Hz","range":"von 0 mV bis 202 mV","cmc":"0,071 % + 24 µV"},{"name":"45 Hz bis 1 kHz","range":"von 0 mV bis 202 mV","cmc":"0,018 % + 24 µV"},{"name":"1 kHz bis 20 kHz","range":"von 0 mV bis 202 mV","cmc":"0,020 % + 33 µV"},{"name":"20 kHz bis 100 kHz","range":"von 0 mV bis 202 mV","cmc":"0,13 % + 56 µV"},{"name":"100 kHz bis 500 kHz","range":"von 0 mV bis 202 mV","cmc":"0,35 % + 0,10 mV"},{"name":"10 Hz bis 45 Hz","range":"von 0,202 V bis 2,02 V","cmc":"0,053 % + 0,21 mV"},{"name":"45 Hz bis 1 kHz","range":"von 0,202 V bis 2,02 V","cmc":"0,019 % + 0,12 mV"},{"name":"1 kHz bis 20 kHz","range":"von 0,202 V bis 2,02 V","cmc":"0,020 % + 0,21 mV"},{"name":"20 kHz bis 100 kHz","range":"von 0,202 V bis 2,02 V","cmc":"0,067 % + 0,30 mV"},{"name":"100 kHz bis 500 kHz","range":"von 0,202 V bis 2,02 V","cmc":"0,29 % + 0,46 mV"},{"name":"10 Hz bis 45 Hz","range":"von 2,02 V bis 20,2 V","cmc":"0,050 % + 2,0 mV"},{"name":"45 Hz bis 1 kHz","range":"von 2,02 V bis 20,2 V","cmc":"0,017 % + 1,3 mV"},{"name":"1 kHz bis 20 kHz","range":"von 2,02 V bis 20,2 V","cmc":"0,021 % + 1,8 mV"},{"name":"20 kHz bis 100 kHz","range":"von 2,02 V bis 20,2 V","cmc":"0,083 % + 3,8 mV"},{"name":"30 Hz bis 45 Hz","range":"von 20,2 V bis 202 V","cmc":"0,050 % + 24 mV"},{"name":"45 Hz bis 1 kHz","range":"von 20,2 V bis 202 V","cmc":"0,017 % + 13 mV"},{"name":"1 kHz bis 10 kHz","range":"von 20,2 V bis 202 V","cmc":"0,021 % + 19 mV"},{"name":"10 kHz bis 40 kHz","range":"von 20,2 V bis 202 V","cmc":"0,035 % + 31 mV"},{"name":"30 Hz bis 45 Hz","range":"von 202 V bis 1020 V","cmc":"0,060 % + 0,21 V"},{"name":"45 Hz bis 1 kHz","range":"von 202 V bis 1020 V","cmc":"0,024 % + 0,08 V"},{"name":"1 kHz bis 10 kHz","range":"von 202 V bis 1020 V","cmc":"0,039 % + 0,13 V"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Wechselspannung / Wechselspannungsmessgeräte Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter 10 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 20 kHz 20 kHz bis 100 kHz 100 kHz bis 500 kHz 10 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 20 kHz 20 kHz bis 100 kHz 100 kHz bis 500 kHz 10 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 20 kHz 20 kHz bis 100 kHz 30 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 10 kHz 10 kHz bis 40 kHz 30 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 10 kHz KP-PB-112","technique_de":"Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter","techniques_de":["Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter"],"test_object_de":"Wechselspannung / Wechselspannungsmessgeräte"},{"_id":"2fd1f12a5582377ddd1dbebe","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / źródła prądu przemiennego","test_object_en":"AC current / AC current sources","test_object_zh":"交流电流 / 交流电流源","test_object_cs":"Střídavý proud / Zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 40 Hz","range":"od 0 µA do 100 µA","cmc":"0,061 % + 24 nA"},{"name":"40 Hz do 1 kHz","range":"od 0 µA do 100 µA","cmc":"0,039 % + 16 nA"},{"name":"1 kHz do 10 kHz","range":"od 0 µA do 100 µA","cmc":"0,083 % + 32 nA"},{"name":"10 Hz do 40 Hz","range":"od 100 µA do 1 mA","cmc":"0,058 % + 0,21 µA"},{"name":"40 Hz do 1 kHz","range":"od 100 µA do 1 mA","cmc":"0,037 % + 0,19 µA"},{"name":"1 kHz do 10 kHz","range":"od 100 µA do 1 mA","cmc":"0,082 % + 0,31 µA"},{"name":"10 Hz do 40 Hz","range":"od 1 mA do 10 mA","cmc":"0,058 % + 3,1 µA"},{"name":"40 Hz do 1 kHz","range":"od 1 mA do 10 mA","cmc":"0,037 % + 1,9 µA"},{"name":"1 kHz do 10 kHz","range":"od 1 mA do 10 mA","cmc":"0,081 % + 3,1 µA"},{"name":"10 Hz do 40 Hz","range":"od 10 mA do 100 mA","cmc":"0,059 % + 27 µA"},{"name":"40 Hz do 1 kHz","range":"od 10 mA do 100 mA","cmc":"0,035 % + 12 µA"},{"name":"1 kHz do 10 kHz","range":"od 10 mA do 100 mA","cmc":"0,082 % + 30 µA"},{"name":"10 Hz do 40 Hz","range":"od 100 mA do 1 A","cmc":"0,074 % + 0,34 mA"},{"name":"40 Hz do 1 kHz","range":"od 100 mA do 1 A","cmc":"0,054 % + 0,17 mA"},{"name":"1 kHz do 10 kHz","range":"od 100 mA do 1 A","cmc":"0,081 % + 0,5 mA"},{"name":"10 Hz do 40 Hz","range":"od 1 A do 10 A","cmc":"0,10 % + 5,8 mA"},{"name":"40 Hz do 1 kHz","range":"od 1 A do 10 A","cmc":"0,091 % + 3,2 mA"},{"name":"10 Hz do 40 Hz","range":"od 10 A do 30 A","cmc":"0,093 % + 13 mA"},{"name":"40 Hz do 1 kHz","range":"od 10 A do 30 A","cmc":"0,082 % + 9,1 mA"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"0 µA to 100 µA","cmc":"0,061 % + 24 nA"},{"name":"40 Hz to 1 kHz","range":"0 µA to 100 µA","cmc":"0,039 % + 16 nA"},{"name":"1 kHz to 10 kHz","range":"0 µA to 100 µA","cmc":"0,083 % + 32 nA"},{"name":"10 Hz to 40 Hz","range":"100 µA to 1 mA","cmc":"0,058 % + 0,21 µA"},{"name":"40 Hz to 1 kHz","range":"100 µA to 1 mA","cmc":"0,037 % + 0,19 µA"},{"name":"1 kHz to 10 kHz","range":"100 µA to 1 mA","cmc":"0,082 % + 0,31 µA"},{"name":"10 Hz to 40 Hz","range":"1 mA to 10 mA","cmc":"0,058 % + 3,1 µA"},{"name":"40 Hz to 1 kHz","range":"1 mA to 10 mA","cmc":"0,037 % + 1,9 µA"},{"name":"1 kHz to 10 kHz","range":"1 mA to 10 mA","cmc":"0,081 % + 3,1 µA"},{"name":"10 Hz to 40 Hz","range":"10 mA to 100 mA","cmc":"0,059 % + 27 µA"},{"name":"40 Hz to 1 kHz","range":"10 mA to 100 mA","cmc":"0,035 % + 12 µA"},{"name":"1 kHz to 10 kHz","range":"10 mA to 100 mA","cmc":"0,082 % + 30 µA"},{"name":"10 Hz to 40 Hz","range":"100 mA to 1 A","cmc":"0,074 % + 0,34 mA"},{"name":"40 Hz to 1 kHz","range":"100 mA to 1 A","cmc":"0,054 % + 0,17 mA"},{"name":"1 kHz to 10 kHz","range":"100 mA to 1 A","cmc":"0,081 % + 0,5 mA"},{"name":"10 Hz to 40 Hz","range":"1 A to 10 A","cmc":"0,10 % + 5,8 mA"},{"name":"40 Hz to 1 kHz","range":"1 A to 10 A","cmc":"0,091 % + 3,2 mA"},{"name":"10 Hz to 40 Hz","range":"10 A to 30 A","cmc":"0,093 % + 13 mA"},{"name":"40 Hz to 1 kHz","range":"10 A to 30 A","cmc":"0,082 % + 9,1 mA"}],"parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"0 µA 至 100 µA","cmc":"0,061 % + 24 nA"},{"name":"40 Hz 至 1 kHz","range":"0 µA 至 100 µA","cmc":"0,039 % + 16 nA"},{"name":"1 kHz 至 10 kHz","range":"0 µA 至 100 µA","cmc":"0,083 % + 32 nA"},{"name":"10 Hz 至 40 Hz","range":"100 µA 至 1 mA","cmc":"0,058 % + 0,21 µA"},{"name":"40 Hz 至 1 kHz","range":"100 µA 至 1 mA","cmc":"0,037 % + 0,19 µA"},{"name":"1 kHz 至 10 kHz","range":"100 µA 至 1 mA","cmc":"0,082 % + 0,31 µA"},{"name":"10 Hz 至 40 Hz","range":"1 mA 至 10 mA","cmc":"0,058 % + 3,1 µA"},{"name":"40 Hz 至 1 kHz","range":"1 mA 至 10 mA","cmc":"0,037 % + 1,9 µA"},{"name":"1 kHz 至 10 kHz","range":"1 mA 至 10 mA","cmc":"0,081 % + 3,1 µA"},{"name":"10 Hz 至 40 Hz","range":"10 mA 至 100 mA","cmc":"0,059 % + 27 µA"},{"name":"40 Hz 至 1 kHz","range":"10 mA 至 100 mA","cmc":"0,035 % + 12 µA"},{"name":"1 kHz 至 10 kHz","range":"10 mA 至 100 mA","cmc":"0,082 % + 30 µA"},{"name":"10 Hz 至 40 Hz","range":"100 mA 至 1 A","cmc":"0,074 % + 0,34 mA"},{"name":"40 Hz 至 1 kHz","range":"100 mA 至 1 A","cmc":"0,054 % + 0,17 mA"},{"name":"1 kHz 至 10 kHz","range":"100 mA 至 1 A","cmc":"0,081 % + 0,5 mA"},{"name":"10 Hz 至 40 Hz","range":"1 A 至 10 A","cmc":"0,10 % + 5,8 mA"},{"name":"40 Hz 至 1 kHz","range":"1 A 至 10 A","cmc":"0,091 % + 3,2 mA"},{"name":"10 Hz 至 40 Hz","range":"10 A 至 30 A","cmc":"0,093 % + 13 mA"},{"name":"40 Hz 至 1 kHz","range":"10 A 至 30 A","cmc":"0,082 % + 9,1 mA"}],"parameters_cs":[{"name":"10 Hz až 40 Hz","range":"0 µA až 100 µA","cmc":"0,061 % + 24 nA"},{"name":"40 Hz až 1 kHz","range":"0 µA až 100 µA","cmc":"0,039 % + 16 nA"},{"name":"1 kHz až 10 kHz","range":"0 µA až 100 µA","cmc":"0,083 % + 32 nA"},{"name":"10 Hz až 40 Hz","range":"100 µA až 1 mA","cmc":"0,058 % + 0,21 µA"},{"name":"40 Hz až 1 kHz","range":"100 µA až 1 mA","cmc":"0,037 % + 0,19 µA"},{"name":"1 kHz až 10 kHz","range":"100 µA až 1 mA","cmc":"0,082 % + 0,31 µA"},{"name":"10 Hz až 40 Hz","range":"1 mA až 10 mA","cmc":"0,058 % + 3,1 µA"},{"name":"40 Hz až 1 kHz","range":"1 mA až 10 mA","cmc":"0,037 % + 1,9 µA"},{"name":"1 kHz až 10 kHz","range":"1 mA až 10 mA","cmc":"0,081 % + 3,1 µA"},{"name":"10 Hz až 40 Hz","range":"10 mA až 100 mA","cmc":"0,059 % + 27 µA"},{"name":"40 Hz až 1 kHz","range":"10 mA až 100 mA","cmc":"0,035 % + 12 µA"},{"name":"1 kHz až 10 kHz","range":"10 mA až 100 mA","cmc":"0,082 % + 30 µA"},{"name":"10 Hz až 40 Hz","range":"100 mA až 1 A","cmc":"0,074 % + 0,34 mA"},{"name":"40 Hz až 1 kHz","range":"100 mA až 1 A","cmc":"0,054 % + 0,17 mA"},{"name":"1 kHz až 10 kHz","range":"100 mA až 1 A","cmc":"0,081 % + 0,5 mA"},{"name":"10 Hz až 40 Hz","range":"1 A až 10 A","cmc":"0,10 % + 5,8 mA"},{"name":"40 Hz až 1 kHz","range":"1 A až 10 A","cmc":"0,091 % + 3,2 mA"},{"name":"10 Hz až 40 Hz","range":"10 A až 30 A","cmc":"0,093 % + 13 mA"},{"name":"40 Hz až 1 kHz","range":"10 A až 30 A","cmc":"0,082 % + 9,1 mA"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 40 Hz od 0 µA do 100 µA CMC 0,061 % + 24 nA\n40 Hz do 1 kHz od 0 µA do 100 µA CMC 0,039 % + 16 nA\n1 kHz do 10 kHz od 0 µA do 100 µA CMC 0,083 % + 32 nA\n10 Hz do 40 Hz od 100 µA do 1 mA CMC 0,058 % + 0,21 µA\n40 Hz do 1 kHz od 100 µA do 1 mA CMC 0,037 % + 0,19 µA\n1 kHz do 10 kHz od 100 µA do 1 mA CMC 0,082 % + 0,31 µA\n10 Hz do 40 Hz od 1 mA do 10 mA CMC 0,058 % + 3,1 µA\n40 Hz do 1 kHz od 1 mA do 10 mA CMC 0,037 % + 1,9 µA\n1 kHz do 10 kHz od 1 mA do 10 mA CMC 0,081 % + 3,1 µA\n10 Hz do 40 Hz od 10 mA do 100 mA CMC 0,059 % + 27 µA\n40 Hz do 1 kHz od 10 mA do 100 mA CMC 0,035 % + 12 µA\n1 kHz do 10 kHz od 10 mA do 100 mA CMC 0,082 % + 30 µA\n10 Hz do 40 Hz od 100 mA do 1 A CMC 0,074 % + 0,34 mA\n40 Hz do 1 kHz od 100 mA do 1 A CMC 0,054 % + 0,17 mA\n1 kHz do 10 kHz od 100 mA do 1 A CMC 0,081 % + 0,5 mA\n10 Hz do 40 Hz od 1 A do 10 A CMC 0,10 % + 5,8 mA\n40 Hz do 1 kHz od 1 A do 10 A CMC 0,091 % + 3,2 mA\n10 Hz do 40 Hz od 10 A do 30 A CMC 0,093 % + 13 mA\n40 Hz do 1 kHz od 10 A do 30 A CMC 0,082 % + 9,1 mA\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP-PB-113","norm_bases":["KP-PB-113"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 10 Hz do 40 Hz od 0 µA do 100 µA CMC 0,061 % + 24 nA 40 Hz do 1 kHz od 0 µA do 100 µA CMC 0,039 % + 16 nA 1 kHz do 10 kHz od 0 µA do 100 µA CMC 0,083 % + 32 nA 10 Hz do 40 Hz od 100 µA do 1 mA CMC 0,058 % + 0,21 µA 40 Hz do 1 kHz od 100 µA do 1 mA CMC 0,037 % + 0,19 µA 1 kHz do 10 kHz od 100 µA do 1 mA CMC 0,082 % + 0,31 µA 10 Hz do 40 Hz od 1 mA do 10 mA CMC 0,058 % + 3,1 µA 40 Hz do 1 kHz od 1 mA do 10 mA CMC 0,037 % + 1,9 µA 1 kHz do 10 kHz od 1 mA do 10 mA CMC 0,081 % + 3,1 µA 10 Hz do 40 Hz od 10 mA do 100 mA CMC 0,059 % + 27 µA 40 Hz do 1 kHz od 10 mA do 100 mA CMC 0,035 % + 12 µA 1 kHz do 10 kHz od 10 mA do 100 mA CMC 0,082 % + 30 µA 10 Hz do 40 Hz od 100 mA do 1 A CMC 0,074 % + 0,34 mA 40 Hz do 1 kHz od 100 mA do 1 A CMC 0,054 % + 0,17 mA 1 kHz do 10 kHz od 100 mA do 1 A CMC 0,081 % + 0,5 mA 10 Hz do 40 Hz od 1 A do 10 A CMC 0,10 % + 5,8 mA 40 Hz do 1 kHz od 1 A do 10 A CMC 0,091 % + 3,2 mA 10 Hz do 40 Hz od 10 A do 30 A CMC 0,093 % + 13 mA 40 Hz do 1 kHz od 10 A do 30 A CMC 0,082 % + 9,1 mA Střídavý proud / Zdroje střídavého proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 10 Hz až 40 Hz 0 µA až 100 µA CMC 0,061 % + 24 nA 40 Hz až 1 kHz 0 µA až 100 µA CMC 0,039 % + 16 nA 1 kHz až 10 kHz 0 µA až 100 µA CMC 0,083 % + 32 nA 10 Hz až 40 Hz 100 µA až 1 mA CMC 0,058 % + 0,21 µA 40 Hz až 1 kHz 100 µA až 1 mA CMC 0,037 % + 0,19 µA 1 kHz až 10 kHz 100 µA až 1 mA CMC 0,082 % + 0,31 µA 10 Hz až 40 Hz 1 mA až 10 mA CMC 0,058 % + 3,1 µA 40 Hz až 1 kHz 1 mA až 10 mA CMC 0,037 % + 1,9 µA 1 kHz až 10 kHz 1 mA až 10 mA CMC 0,081 % + 3,1 µA 10 Hz až 40 Hz 10 mA až 100 mA CMC 0,059 % + 27 µA 40 Hz až 1 kHz 10 mA až 100 mA CMC 0,035 % + 12 µA 1 kHz až 10 kHz 10 mA až 100 mA CMC 0,082 % + 30 µA 10 Hz až 40 Hz 100 mA až 1 A CMC 0,074 % + 0,34 mA 40 Hz až 1 kHz 100 mA až 1 A CMC 0,054 % + 0,17 mA 1 kHz až 10 kHz 100 mA až 1 A CMC 0,081 % + 0,5 mA 10 Hz až 40 Hz 1 A až 10 A CMC 0,10 % + 5,8 mA 40 Hz až 1 kHz 1 A až 10 A CMC 0,091 % + 3,2 mA 10 Hz až 40 Hz 10 A až 30 A CMC 0,093 % + 13 mA 40 Hz až 1 kHz 10 A až 30 A CMC 0,082 % + 9,1 mA KP-PB-113 Prad przemienny / zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 10 Hz do 40 Hz od 0 µA do 100 µA CMC 0,061 % + 24 nA 40 Hz do 1 kHz od 0 µA do 100 µA CMC 0,039 % + 16 nA 1 kHz do 10 kHz od 0 µA do 100 µA CMC 0,083 % + 32 nA 10 Hz do 40 Hz od 100 µA do 1 mA CMC 0,058 % + 0,21 µA 40 Hz do 1 kHz od 100 µA do 1 mA CMC 0,037 % + 0,19 µA 1 kHz do 10 kHz od 100 µA do 1 mA CMC 0,082 % + 0,31 µA 10 Hz do 40 Hz od 1 mA do 10 mA CMC 0,058 % + 3,1 µA 40 Hz do 1 kHz od 1 mA do 10 mA CMC 0,037 % + 1,9 µA 1 kHz do 10 kHz od 1 mA do 10 mA CMC 0,081 % + 3,1 µA 10 Hz do 40 Hz od 10 mA do 100 mA CMC 0,059 % + 27 µA 40 Hz do 1 kHz od 10 mA do 100 mA CMC 0,035 % + 12 µA 1 kHz do 10 kHz od 10 mA do 100 mA CMC 0,082 % + 30 µA 10 Hz do 40 Hz od 100 mA do 1 A CMC 0,074 % + 0,34 mA 40 Hz do 1 kHz od 100 mA do 1 A CMC 0,054 % + 0,17 mA 1 kHz do 10 kHz od 100 mA do 1 A CMC 0,081 % + 0,5 mA 10 Hz do 40 Hz od 1 A do 10 A CMC 0,10 % + 5,8 mA 40 Hz do 1 kHz od 1 A do 10 A CMC 0,091 % + 3,2 mA 10 Hz do 40 Hz od 10 A do 30 A CMC 0,093 % + 13 mA 40 Hz do 1 kHz od 10 A do 30 A CMC 0,082 % + 9,1 mA Stridavy proud / Zdroje stridaveho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 10 Hz az 40 Hz 0 µA az 100 µA CMC 0,061 % + 24 nA 40 Hz az 1 kHz 0 µA az 100 µA CMC 0,039 % + 16 nA 1 kHz az 10 kHz 0 µA az 100 µA CMC 0,083 % + 32 nA 10 Hz az 40 Hz 100 µA az 1 mA CMC 0,058 % + 0,21 µA 40 Hz az 1 kHz 100 µA az 1 mA CMC 0,037 % + 0,19 µA 1 kHz az 10 kHz 100 µA az 1 mA CMC 0,082 % + 0,31 µA 10 Hz az 40 Hz 1 mA az 10 mA CMC 0,058 % + 3,1 µA 40 Hz az 1 kHz 1 mA az 10 mA CMC 0,037 % + 1,9 µA 1 kHz az 10 kHz 1 mA az 10 mA CMC 0,081 % + 3,1 µA 10 Hz az 40 Hz 10 mA az 100 mA CMC 0,059 % + 27 µA 40 Hz az 1 kHz 10 mA az 100 mA CMC 0,035 % + 12 µA 1 kHz az 10 kHz 10 mA az 100 mA CMC 0,082 % + 30 µA 10 Hz az 40 Hz 100 mA az 1 A CMC 0,074 % + 0,34 mA 40 Hz az 1 kHz 100 mA az 1 A CMC 0,054 % + 0,17 mA 1 kHz az 10 kHz 100 mA az 1 A CMC 0,081 % + 0,5 mA 10 Hz az 40 Hz 1 A az 10 A CMC 0,10 % + 5,8 mA 40 Hz az 1 kHz 1 A az 10 A CMC 0,091 % + 3,2 mA 10 Hz az 40 Hz 10 A az 30 A CMC 0,093 % + 13 mA 40 Hz az 1 kHz 10 A az 30 A CMC 0,082 % + 9,1 mA KP-PB-113","search_en":"AC current / AC current sources Calibration – electrical quantities Direct measurement by a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement by a reference multimeter 10 Hz to 40 Hz 40 Hz to 1 kHz 1 kHz to 10 kHz 10 Hz to 40 Hz 40 Hz to 1 kHz 1 kHz to 10 kHz 10 Hz to 40 Hz 40 Hz to 1 kHz 1 kHz to 10 kHz 10 Hz to 40 Hz 40 Hz to 1 kHz 1 kHz to 10 kHz 10 Hz to 40 Hz 40 Hz to 1 kHz 1 kHz to 10 kHz 10 Hz to 40 Hz 40 Hz to 1 kHz 10 Hz to 40 Hz 40 Hz to 1 kHz KP-PB-113","search_zh":"交流电流 / 交流电流源 校准 – 电学量 用标准万用表直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用标准万用表直接测量 10 Hz 至 40 Hz 40 Hz 至 1 kHz 1 kHz 至 10 kHz 10 Hz 至 40 Hz 40 Hz 至 1 kHz 1 kHz 至 10 kHz 10 Hz 至 40 Hz 40 Hz 至 1 kHz 1 kHz 至 10 kHz 10 Hz 至 40 Hz 40 Hz 至 1 kHz 1 kHz 至 10 kHz 10 Hz 至 40 Hz 40 Hz 至 1 kHz 1 kHz 至 10 kHz 10 Hz 至 40 Hz 40 Hz 至 1 kHz 10 Hz 至 40 Hz 40 Hz 至 1 kHz KP-PB-113","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"10 Hz bis 40 Hz","range":"von 0 µA bis 100 µA","cmc":"0,061 % + 24 nA"},{"name":"40 Hz bis 1 kHz","range":"von 0 µA bis 100 µA","cmc":"0,039 % + 16 nA"},{"name":"1 kHz bis 10 kHz","range":"von 0 µA bis 100 µA","cmc":"0,083 % + 32 nA"},{"name":"10 Hz bis 40 Hz","range":"von 100 µA bis 1 mA","cmc":"0,058 % + 0,21 µA"},{"name":"40 Hz bis 1 kHz","range":"von 100 µA bis 1 mA","cmc":"0,037 % + 0,19 µA"},{"name":"1 kHz bis 10 kHz","range":"von 100 µA bis 1 mA","cmc":"0,082 % + 0,31 µA"},{"name":"10 Hz bis 40 Hz","range":"von 1 mA bis 10 mA","cmc":"0,058 % + 3,1 µA"},{"name":"40 Hz bis 1 kHz","range":"von 1 mA bis 10 mA","cmc":"0,037 % + 1,9 µA"},{"name":"1 kHz bis 10 kHz","range":"von 1 mA bis 10 mA","cmc":"0,081 % + 3,1 µA"},{"name":"10 Hz bis 40 Hz","range":"von 10 mA bis 100 mA","cmc":"0,059 % + 27 µA"},{"name":"40 Hz bis 1 kHz","range":"von 10 mA bis 100 mA","cmc":"0,035 % + 12 µA"},{"name":"1 kHz bis 10 kHz","range":"von 10 mA bis 100 mA","cmc":"0,082 % + 30 µA"},{"name":"10 Hz bis 40 Hz","range":"von 100 mA bis 1 A","cmc":"0,074 % + 0,34 mA"},{"name":"40 Hz bis 1 kHz","range":"von 100 mA bis 1 A","cmc":"0,054 % + 0,17 mA"},{"name":"1 kHz bis 10 kHz","range":"von 100 mA bis 1 A","cmc":"0,081 % + 0,5 mA"},{"name":"10 Hz bis 40 Hz","range":"von 1 A bis 10 A","cmc":"0,10 % + 5,8 mA"},{"name":"40 Hz bis 1 kHz","range":"von 1 A bis 10 A","cmc":"0,091 % + 3,2 mA"},{"name":"10 Hz bis 40 Hz","range":"von 10 A bis 30 A","cmc":"0,093 % + 13 mA"},{"name":"40 Hz bis 1 kHz","range":"von 10 A bis 30 A","cmc":"0,082 % + 9,1 mA"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Wechselstrom / Wechselstromquellen Kalibrierung – elektrische Größen Direkte Messung mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung mit einem Referenzmultimeter 10 Hz bis 40 Hz 40 Hz bis 1 kHz 1 kHz bis 10 kHz 10 Hz bis 40 Hz 40 Hz bis 1 kHz 1 kHz bis 10 kHz 10 Hz bis 40 Hz 40 Hz bis 1 kHz 1 kHz bis 10 kHz 10 Hz bis 40 Hz 40 Hz bis 1 kHz 1 kHz bis 10 kHz 10 Hz bis 40 Hz 40 Hz bis 1 kHz 1 kHz bis 10 kHz 10 Hz bis 40 Hz 40 Hz bis 1 kHz 10 Hz bis 40 Hz 40 Hz bis 1 kHz KP-PB-113","technique_de":"Direkte Messung mit einem Referenzmultimeter","techniques_de":["Direkte Messung mit einem Referenzmultimeter"],"test_object_de":"Wechselstrom / Wechselstromquellen"},{"_id":"47ed0c3739ebc6659a725c3f","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / źródła prądu przemiennego","test_object_en":"AC current / AC current sources","test_object_zh":"交流电流 / 交流电流源","test_object_cs":"Střídavý proud / Zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"30 Hz do 60 Hz","range":"od 0 A do 4 A","cmc":"0,72 % + 0,003 A"},{"name":"30 Hz do 60 Hz","range":"od 4 A do 40 A","cmc":"0,71 % + 0,03 A"},{"name":"30 Hz do 60 Hz","range":"od 40 A do 200 A","cmc":"1,2 % + 0,5 A"},{"name":"30 Hz do 60 Hz","range":"od 200 A do 400 A","cmc":"1,1 % + 1,3 A"},{"name":"30 Hz do 60 Hz","range":"od 400 A do 1500 A","cmc":"1,3 % + 1,6 A"},{"name":"30 Hz do 60 Hz","range":"od 1500 A do 2000 A","cmc":"1,1 % + 4,6 A"}],"parameters_en":[{"name":"30 Hz to 60 Hz","range":"0 A to 4 A","cmc":"0,72 % + 0,003 A"},{"name":"30 Hz to 60 Hz","range":"4 A to 40 A","cmc":"0,71 % + 0,03 A"},{"name":"30 Hz to 60 Hz","range":"40 A to 200 A","cmc":"1,2 % + 0,5 A"},{"name":"30 Hz to 60 Hz","range":"200 A to 400 A","cmc":"1,1 % + 1,3 A"},{"name":"30 Hz to 60 Hz","range":"400 A to 1500 A","cmc":"1,3 % + 1,6 A"},{"name":"30 Hz to 60 Hz","range":"1500 A to 2000 A","cmc":"1,1 % + 4,6 A"}],"parameters_zh":[{"name":"30 Hz 至 60 Hz","range":"0 A 至 4 A","cmc":"0,72 % + 0,003 A"},{"name":"30 Hz 至 60 Hz","range":"4 A 至 40 A","cmc":"0,71 % + 0,03 A"},{"name":"30 Hz 至 60 Hz","range":"40 A 至 200 A","cmc":"1,2 % + 0,5 A"},{"name":"30 Hz 至 60 Hz","range":"200 A 至 400 A","cmc":"1,1 % + 1,3 A"},{"name":"30 Hz 至 60 Hz","range":"400 A 至 1500 A","cmc":"1,3 % + 1,6 A"},{"name":"30 Hz 至 60 Hz","range":"1500 A 至 2000 A","cmc":"1,1 % + 4,6 A"}],"parameters_cs":[{"name":"30 Hz až 60 Hz","range":"0 A až 4 A","cmc":"0,72 % + 0,003 A"},{"name":"30 Hz až 60 Hz","range":"4 A až 40 A","cmc":"0,71 % + 0,03 A"},{"name":"30 Hz až 60 Hz","range":"40 A až 200 A","cmc":"1,2 % + 0,5 A"},{"name":"30 Hz až 60 Hz","range":"200 A až 400 A","cmc":"1,1 % + 1,3 A"},{"name":"30 Hz až 60 Hz","range":"400 A až 1500 A","cmc":"1,3 % + 1,6 A"},{"name":"30 Hz až 60 Hz","range":"1500 A až 2000 A","cmc":"1,1 % + 4,6 A"}],"technique":"Pomiar bezpośredni wzorcowym multimetrem cęgowym lub cęgami prądowymi","technique_en":"Direct measurement by a reference clamp multimeter or a current clamp","technique_zh":"用标准钳形万用表或电流钳直接测量","technique_cs":"Přímé měření etalonovým klešťovým multimetrem nebo proudovými kleštěmi","techniques":["Pomiar bezpośredni wzorcowym multimetrem cęgowym lub cęgami prądowymi"],"techniques_en":["Direct measurement by a reference clamp multimeter or a current clamp"],"techniques_zh":["用标准钳形万用表或电流钳直接测量"],"techniques_cs":["Přímé měření etalonovým klešťovým multimetrem nebo proudovými kleštěmi"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n30 Hz do 60 Hz od 0 A do 4 A CMC 0,72 % + 0,003 A\n30 Hz do 60 Hz od 4 A do 40 A CMC 0,71 % + 0,03 A\n30 Hz do 60 Hz od 40 A do 200 A CMC 1,2 % + 0,5 A\n30 Hz do 60 Hz od 200 A do 400 A CMC 1,1 % + 1,3 A\n30 Hz do 60 Hz od 400 A do 1500 A CMC 1,3 % + 1,6 A\n30 Hz do 60 Hz od 1500 A do 2000 A CMC 1,1 % + 4,6 A\nPomiar bezpośredni wzorcowym multimetrem cęgowym lub cęgami prądowymi","reference":"KP-PB-113","norm_bases":["KP-PB-113"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorcowym multimetrem cęgowym lub cęgami prądowymi 30 Hz do 60 Hz od 0 A do 4 A CMC 0,72 % + 0,003 A 30 Hz do 60 Hz od 4 A do 40 A CMC 0,71 % + 0,03 A 30 Hz do 60 Hz od 40 A do 200 A CMC 1,2 % + 0,5 A 30 Hz do 60 Hz od 200 A do 400 A CMC 1,1 % + 1,3 A 30 Hz do 60 Hz od 400 A do 1500 A CMC 1,3 % + 1,6 A 30 Hz do 60 Hz od 1500 A do 2000 A CMC 1,1 % + 4,6 A Střídavý proud / Zdroje střídavého proudu Kalibrace – elektrické veličiny Přímé měření etalonovým klešťovým multimetrem nebo proudovými kleštěmi 30 Hz až 60 Hz 0 A až 4 A CMC 0,72 % + 0,003 A 30 Hz až 60 Hz 4 A až 40 A CMC 0,71 % + 0,03 A 30 Hz až 60 Hz 40 A až 200 A CMC 1,2 % + 0,5 A 30 Hz až 60 Hz 200 A až 400 A CMC 1,1 % + 1,3 A 30 Hz až 60 Hz 400 A až 1500 A CMC 1,3 % + 1,6 A 30 Hz až 60 Hz 1500 A až 2000 A CMC 1,1 % + 4,6 A KP-PB-113 Prad przemienny / zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcowym multimetrem cegowym lub cegami pradowymi 30 Hz do 60 Hz od 0 A do 4 A CMC 0,72 % + 0,003 A 30 Hz do 60 Hz od 4 A do 40 A CMC 0,71 % + 0,03 A 30 Hz do 60 Hz od 40 A do 200 A CMC 1,2 % + 0,5 A 30 Hz do 60 Hz od 200 A do 400 A CMC 1,1 % + 1,3 A 30 Hz do 60 Hz od 400 A do 1500 A CMC 1,3 % + 1,6 A 30 Hz do 60 Hz od 1500 A do 2000 A CMC 1,1 % + 4,6 A Stridavy proud / Zdroje stridaveho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym klestovym multimetrem nebo proudovymi klestemi 30 Hz az 60 Hz 0 A az 4 A CMC 0,72 % + 0,003 A 30 Hz az 60 Hz 4 A az 40 A CMC 0,71 % + 0,03 A 30 Hz az 60 Hz 40 A az 200 A CMC 1,2 % + 0,5 A 30 Hz az 60 Hz 200 A az 400 A CMC 1,1 % + 1,3 A 30 Hz az 60 Hz 400 A az 1500 A CMC 1,3 % + 1,6 A 30 Hz az 60 Hz 1500 A az 2000 A CMC 1,1 % + 4,6 A KP-PB-113","search_en":"AC current / AC current sources Calibration – electrical quantities Direct measurement by a reference clamp multimeter or a current clamp Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement by a reference clamp multimeter or a current clamp 30 Hz to 60 Hz 30 Hz to 60 Hz 30 Hz to 60 Hz 30 Hz to 60 Hz 30 Hz to 60 Hz 30 Hz to 60 Hz KP-PB-113","search_zh":"交流电流 / 交流电流源 校准 – 电学量 用标准钳形万用表或电流钳直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用标准钳形万用表或电流钳直接测量 30 Hz 至 60 Hz 30 Hz 至 60 Hz 30 Hz 至 60 Hz 30 Hz 至 60 Hz 30 Hz 至 60 Hz 30 Hz 至 60 Hz KP-PB-113","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"30 Hz bis 60 Hz","range":"von 0 A bis 4 A","cmc":"0,72 % + 0,003 A"},{"name":"30 Hz bis 60 Hz","range":"von 4 A bis 40 A","cmc":"0,71 % + 0,03 A"},{"name":"30 Hz bis 60 Hz","range":"von 40 A bis 200 A","cmc":"1,2 % + 0,5 A"},{"name":"30 Hz bis 60 Hz","range":"von 200 A bis 400 A","cmc":"1,1 % + 1,3 A"},{"name":"30 Hz bis 60 Hz","range":"von 400 A bis 1500 A","cmc":"1,3 % + 1,6 A"},{"name":"30 Hz bis 60 Hz","range":"von 1500 A bis 2000 A","cmc":"1,1 % + 4,6 A"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Wechselstrom / Wechselstromquellen Kalibrierung – elektrische Größen Direkte Messung mit einem Referenz-Zangenmultimeter oder einer Stromzange Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung mit einem Referenz-Zangenmultimeter oder einer Stromzange 30 Hz bis 60 Hz 30 Hz bis 60 Hz 30 Hz bis 60 Hz 30 Hz bis 60 Hz 30 Hz bis 60 Hz 30 Hz bis 60 Hz KP-PB-113","technique_de":"Direkte Messung mit einem Referenz-Zangenmultimeter oder einer Stromzange","techniques_de":["Direkte Messung mit einem Referenz-Zangenmultimeter oder einer Stromzange"],"test_object_de":"Wechselstrom / Wechselstromquellen"},{"_id":"7fe32d010e6e43d5761fe363","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / przyrządy do pomiaru prądu przemiennego","test_object_en":"AC current / AC current meters","test_object_zh":"交流电流 / 交流电流测量仪器","test_object_cs":"Střídavý proud / Měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 45 Hz","range":"od 10 µA do 202 µA","cmc":"0,20 % + 0,25 µA"},{"name":"45 Hz do 1 kHz","range":"od 10 µA do 202 µA","cmc":"0,071 % + 0,15 µA"},{"name":"1 kHz do 10 kHz","range":"od 10 µA do 202 µA","cmc":"0,96 % + 0,20 µA"},{"name":"10 Hz do 45 Hz","range":"od 0,202 mA do 2,02 mA","cmc":"0,19 % + 0,31 µA"},{"name":"45 Hz do 1 kHz","range":"od 0,202 mA do 2,02 mA","cmc":"0,055 % + 0,27 µA"},{"name":"1 kHz do 10 kHz","range":"od 0,202 mA do 2,02 mA","cmc":"0,50 % + 0,35 µA"},{"name":"10 Hz do 45 Hz","range":"od 2,02 mA do 20,2 mA","cmc":"0,19 % + 4,1 µA"},{"name":"45 Hz do 1 kHz","range":"od 2,02 mA do 20,2 mA","cmc":"0,048 % + 2,5 µA"},{"name":"1 kHz do 10 kHz","range":"od 2,02 mA do 20,2 mA","cmc":"0,25 % + 3,4 µA"},{"name":"10 Hz do 45 Hz","range":"od 20,2 mA do 202 mA","cmc":"0,19 % + 41 µA"},{"name":"45 Hz do 1 kHz","range":"od 20,2 mA do 202 mA","cmc":"0,049 % + 25 µA"},{"name":"1 kHz do 10 kHz","range":"od 20,2 mA do 202 mA","cmc":"0,50 % + 43 µA"},{"name":"10 Hz do 45 Hz","range":"od 0,202 A do 2,02 A","cmc":"0,19 % + 0,36 mA"},{"name":"45 Hz do 1 kHz","range":"od 0,202 A do 2,02 A","cmc":"0,064 % + 0,28 mA"},{"name":"1 kHz do 5 kHz","range":"od 0,202 A do 2,02 A","cmc":"0,50 % + 0,45 mA"},{"name":"30 Hz do 45 Hz","range":"od 2,02 A do 30 A","cmc":"0,19 % + 3,5 mA"},{"name":"45 Hz do 100 Hz","range":"od 2,02 A do 30 A","cmc":"0,059 % + 2,5 mA"},{"name":"100 Hz do 1 kHz","range":"od 2,02 A do 30 A","cmc":"0,50 % + 4,3 mA"}],"parameters_en":[{"name":"10 Hz to 45 Hz","range":"10 µA to 202 µA","cmc":"0,20 % + 0,25 µA"},{"name":"45 Hz to 1 kHz","range":"10 µA to 202 µA","cmc":"0,071 % + 0,15 µA"},{"name":"1 kHz to 10 kHz","range":"10 µA to 202 µA","cmc":"0,96 % + 0,20 µA"},{"name":"10 Hz to 45 Hz","range":"0,202 mA to 2,02 mA","cmc":"0,19 % + 0,31 µA"},{"name":"45 Hz to 1 kHz","range":"0,202 mA to 2,02 mA","cmc":"0,055 % + 0,27 µA"},{"name":"1 kHz to 10 kHz","range":"0,202 mA to 2,02 mA","cmc":"0,50 % + 0,35 µA"},{"name":"10 Hz to 45 Hz","range":"2,02 mA to 20,2 mA","cmc":"0,19 % + 4,1 µA"},{"name":"45 Hz to 1 kHz","range":"2,02 mA to 20,2 mA","cmc":"0,048 % + 2,5 µA"},{"name":"1 kHz to 10 kHz","range":"2,02 mA to 20,2 mA","cmc":"0,25 % + 3,4 µA"},{"name":"10 Hz to 45 Hz","range":"20,2 mA to 202 mA","cmc":"0,19 % + 41 µA"},{"name":"45 Hz to 1 kHz","range":"20,2 mA to 202 mA","cmc":"0,049 % + 25 µA"},{"name":"1 kHz to 10 kHz","range":"20,2 mA to 202 mA","cmc":"0,50 % + 43 µA"},{"name":"10 Hz to 45 Hz","range":"0,202 A to 2,02 A","cmc":"0,19 % + 0,36 mA"},{"name":"45 Hz to 1 kHz","range":"0,202 A to 2,02 A","cmc":"0,064 % + 0,28 mA"},{"name":"1 kHz to 5 kHz","range":"0,202 A to 2,02 A","cmc":"0,50 % + 0,45 mA"},{"name":"30 Hz to 45 Hz","range":"2,02 A to 30 A","cmc":"0,19 % + 3,5 mA"},{"name":"45 Hz to 100 Hz","range":"2,02 A to 30 A","cmc":"0,059 % + 2,5 mA"},{"name":"100 Hz to 1 kHz","range":"2,02 A to 30 A","cmc":"0,50 % + 4,3 mA"}],"parameters_zh":[{"name":"10 Hz 至 45 Hz","range":"10 µA 至 202 µA","cmc":"0,20 % + 0,25 µA"},{"name":"45 Hz 至 1 kHz","range":"10 µA 至 202 µA","cmc":"0,071 % + 0,15 µA"},{"name":"1 kHz 至 10 kHz","range":"10 µA 至 202 µA","cmc":"0,96 % + 0,20 µA"},{"name":"10 Hz 至 45 Hz","range":"0,202 mA 至 2,02 mA","cmc":"0,19 % + 0,31 µA"},{"name":"45 Hz 至 1 kHz","range":"0,202 mA 至 2,02 mA","cmc":"0,055 % + 0,27 µA"},{"name":"1 kHz 至 10 kHz","range":"0,202 mA 至 2,02 mA","cmc":"0,50 % + 0,35 µA"},{"name":"10 Hz 至 45 Hz","range":"2,02 mA 至 20,2 mA","cmc":"0,19 % + 4,1 µA"},{"name":"45 Hz 至 1 kHz","range":"2,02 mA 至 20,2 mA","cmc":"0,048 % + 2,5 µA"},{"name":"1 kHz 至 10 kHz","range":"2,02 mA 至 20,2 mA","cmc":"0,25 % + 3,4 µA"},{"name":"10 Hz 至 45 Hz","range":"20,2 mA 至 202 mA","cmc":"0,19 % + 41 µA"},{"name":"45 Hz 至 1 kHz","range":"20,2 mA 至 202 mA","cmc":"0,049 % + 25 µA"},{"name":"1 kHz 至 10 kHz","range":"20,2 mA 至 202 mA","cmc":"0,50 % + 43 µA"},{"name":"10 Hz 至 45 Hz","range":"0,202 A 至 2,02 A","cmc":"0,19 % + 0,36 mA"},{"name":"45 Hz 至 1 kHz","range":"0,202 A 至 2,02 A","cmc":"0,064 % + 0,28 mA"},{"name":"1 kHz 至 5 kHz","range":"0,202 A 至 2,02 A","cmc":"0,50 % + 0,45 mA"},{"name":"30 Hz 至 45 Hz","range":"2,02 A 至 30 A","cmc":"0,19 % + 3,5 mA"},{"name":"45 Hz 至 100 Hz","range":"2,02 A 至 30 A","cmc":"0,059 % + 2,5 mA"},{"name":"100 Hz 至 1 kHz","range":"2,02 A 至 30 A","cmc":"0,50 % + 4,3 mA"}],"parameters_cs":[{"name":"10 Hz až 45 Hz","range":"10 µA až 202 µA","cmc":"0,20 % + 0,25 µA"},{"name":"45 Hz až 1 kHz","range":"10 µA až 202 µA","cmc":"0,071 % + 0,15 µA"},{"name":"1 kHz až 10 kHz","range":"10 µA až 202 µA","cmc":"0,96 % + 0,20 µA"},{"name":"10 Hz až 45 Hz","range":"0,202 mA až 2,02 mA","cmc":"0,19 % + 0,31 µA"},{"name":"45 Hz až 1 kHz","range":"0,202 mA až 2,02 mA","cmc":"0,055 % + 0,27 µA"},{"name":"1 kHz až 10 kHz","range":"0,202 mA až 2,02 mA","cmc":"0,50 % + 0,35 µA"},{"name":"10 Hz až 45 Hz","range":"2,02 mA až 20,2 mA","cmc":"0,19 % + 4,1 µA"},{"name":"45 Hz až 1 kHz","range":"2,02 mA až 20,2 mA","cmc":"0,048 % + 2,5 µA"},{"name":"1 kHz až 10 kHz","range":"2,02 mA až 20,2 mA","cmc":"0,25 % + 3,4 µA"},{"name":"10 Hz až 45 Hz","range":"20,2 mA až 202 mA","cmc":"0,19 % + 41 µA"},{"name":"45 Hz až 1 kHz","range":"20,2 mA až 202 mA","cmc":"0,049 % + 25 µA"},{"name":"1 kHz až 10 kHz","range":"20,2 mA až 202 mA","cmc":"0,50 % + 43 µA"},{"name":"10 Hz až 45 Hz","range":"0,202 A až 2,02 A","cmc":"0,19 % + 0,36 mA"},{"name":"45 Hz až 1 kHz","range":"0,202 A až 2,02 A","cmc":"0,064 % + 0,28 mA"},{"name":"1 kHz až 5 kHz","range":"0,202 A až 2,02 A","cmc":"0,50 % + 0,45 mA"},{"name":"30 Hz až 45 Hz","range":"2,02 A až 30 A","cmc":"0,19 % + 3,5 mA"},{"name":"45 Hz až 100 Hz","range":"2,02 A až 30 A","cmc":"0,059 % + 2,5 mA"},{"name":"100 Hz až 1 kHz","range":"2,02 A až 30 A","cmc":"0,50 % + 4,3 mA"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym","technique_en":"Direct measurement on a reference calibrator or comparison with a reference multimeter","technique_zh":"在标准校准器上直接测量或与标准万用表比较","technique_cs":"Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement on a reference calibrator or comparison with a reference multimeter"],"techniques_zh":["在标准校准器上直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 45 Hz od 10 µA do 202 µA CMC 0,20 % + 0,25 µA\n45 Hz do 1 kHz od 10 µA do 202 µA CMC 0,071 % + 0,15 µA\n1 kHz do 10 kHz od 10 µA do 202 µA CMC 0,96 % + 0,20 µA\n10 Hz do 45 Hz od 0,202 mA do 2,02 mA CMC 0,19 % + 0,31 µA\n45 Hz do 1 kHz od 0,202 mA do 2,02 mA CMC 0,055 % + 0,27 µA\n1 kHz do 10 kHz od 0,202 mA do 2,02 mA CMC 0,50 % + 0,35 µA\n10 Hz do 45 Hz od 2,02 mA do 20,2 mA CMC 0,19 % + 4,1 µA\n45 Hz do 1 kHz od 2,02 mA do 20,2 mA CMC 0,048 % + 2,5 µA\n1 kHz do 10 kHz od 2,02 mA do 20,2 mA CMC 0,25 % + 3,4 µA\n10 Hz do 45 Hz od 20,2 mA do 202 mA CMC 0,19 % + 41 µA\n45 Hz do 1 kHz od 20,2 mA do 202 mA CMC 0,049 % + 25 µA\n1 kHz do 10 kHz od 20,2 mA do 202 mA CMC 0,50 % + 43 µA\n10 Hz do 45 Hz od 0,202 A do 2,02 A CMC 0,19 % + 0,36 mA\n45 Hz do 1 kHz od 0,202 A do 2,02 A CMC 0,064 % + 0,28 mA\n1 kHz do 5 kHz od 0,202 A do 2,02 A CMC 0,50 % + 0,45 mA\n30 Hz do 45 Hz od 2,02 A do 30 A CMC 0,19 % + 3,5 mA\n45 Hz do 100 Hz od 2,02 A do 30 A CMC 0,059 % + 2,5 mA\n100 Hz do 1 kHz od 2,02 A do 30 A CMC 0,50 % + 4,3 mA\nPomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym","reference":"KP-PB-113","norm_bases":["KP-PB-113"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym lub porównanie z multimetrem wzorcowym 10 Hz do 45 Hz od 10 µA do 202 µA CMC 0,20 % + 0,25 µA 45 Hz do 1 kHz od 10 µA do 202 µA CMC 0,071 % + 0,15 µA 1 kHz do 10 kHz od 10 µA do 202 µA CMC 0,96 % + 0,20 µA 10 Hz do 45 Hz od 0,202 mA do 2,02 mA CMC 0,19 % + 0,31 µA 45 Hz do 1 kHz od 0,202 mA do 2,02 mA CMC 0,055 % + 0,27 µA 1 kHz do 10 kHz od 0,202 mA do 2,02 mA CMC 0,50 % + 0,35 µA 10 Hz do 45 Hz od 2,02 mA do 20,2 mA CMC 0,19 % + 4,1 µA 45 Hz do 1 kHz od 2,02 mA do 20,2 mA CMC 0,048 % + 2,5 µA 1 kHz do 10 kHz od 2,02 mA do 20,2 mA CMC 0,25 % + 3,4 µA 10 Hz do 45 Hz od 20,2 mA do 202 mA CMC 0,19 % + 41 µA 45 Hz do 1 kHz od 20,2 mA do 202 mA CMC 0,049 % + 25 µA 1 kHz do 10 kHz od 20,2 mA do 202 mA CMC 0,50 % + 43 µA 10 Hz do 45 Hz od 0,202 A do 2,02 A CMC 0,19 % + 0,36 mA 45 Hz do 1 kHz od 0,202 A do 2,02 A CMC 0,064 % + 0,28 mA 1 kHz do 5 kHz od 0,202 A do 2,02 A CMC 0,50 % + 0,45 mA 30 Hz do 45 Hz od 2,02 A do 30 A CMC 0,19 % + 3,5 mA 45 Hz do 100 Hz od 2,02 A do 30 A CMC 0,059 % + 2,5 mA 100 Hz do 1 kHz od 2,02 A do 30 A CMC 0,50 % + 4,3 mA Střídavý proud / Měřidla střídavého proudu Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru nebo porovnání s etalonovým multimetrem 10 Hz až 45 Hz 10 µA až 202 µA CMC 0,20 % + 0,25 µA 45 Hz až 1 kHz 10 µA až 202 µA CMC 0,071 % + 0,15 µA 1 kHz až 10 kHz 10 µA až 202 µA CMC 0,96 % + 0,20 µA 10 Hz až 45 Hz 0,202 mA až 2,02 mA CMC 0,19 % + 0,31 µA 45 Hz až 1 kHz 0,202 mA až 2,02 mA CMC 0,055 % + 0,27 µA 1 kHz až 10 kHz 0,202 mA až 2,02 mA CMC 0,50 % + 0,35 µA 10 Hz až 45 Hz 2,02 mA až 20,2 mA CMC 0,19 % + 4,1 µA 45 Hz až 1 kHz 2,02 mA až 20,2 mA CMC 0,048 % + 2,5 µA 1 kHz až 10 kHz 2,02 mA až 20,2 mA CMC 0,25 % + 3,4 µA 10 Hz až 45 Hz 20,2 mA až 202 mA CMC 0,19 % + 41 µA 45 Hz až 1 kHz 20,2 mA až 202 mA CMC 0,049 % + 25 µA 1 kHz až 10 kHz 20,2 mA až 202 mA CMC 0,50 % + 43 µA 10 Hz až 45 Hz 0,202 A až 2,02 A CMC 0,19 % + 0,36 mA 45 Hz až 1 kHz 0,202 A až 2,02 A CMC 0,064 % + 0,28 mA 1 kHz až 5 kHz 0,202 A až 2,02 A CMC 0,50 % + 0,45 mA 30 Hz až 45 Hz 2,02 A až 30 A CMC 0,19 % + 3,5 mA 45 Hz až 100 Hz 2,02 A až 30 A CMC 0,059 % + 2,5 mA 100 Hz až 1 kHz 2,02 A až 30 A CMC 0,50 % + 4,3 mA KP-PB-113 Prad przemienny / przyrzady do pomiaru pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym lub porownanie z multimetrem wzorcowym 10 Hz do 45 Hz od 10 µA do 202 µA CMC 0,20 % + 0,25 µA 45 Hz do 1 kHz od 10 µA do 202 µA CMC 0,071 % + 0,15 µA 1 kHz do 10 kHz od 10 µA do 202 µA CMC 0,96 % + 0,20 µA 10 Hz do 45 Hz od 0,202 mA do 2,02 mA CMC 0,19 % + 0,31 µA 45 Hz do 1 kHz od 0,202 mA do 2,02 mA CMC 0,055 % + 0,27 µA 1 kHz do 10 kHz od 0,202 mA do 2,02 mA CMC 0,50 % + 0,35 µA 10 Hz do 45 Hz od 2,02 mA do 20,2 mA CMC 0,19 % + 4,1 µA 45 Hz do 1 kHz od 2,02 mA do 20,2 mA CMC 0,048 % + 2,5 µA 1 kHz do 10 kHz od 2,02 mA do 20,2 mA CMC 0,25 % + 3,4 µA 10 Hz do 45 Hz od 20,2 mA do 202 mA CMC 0,19 % + 41 µA 45 Hz do 1 kHz od 20,2 mA do 202 mA CMC 0,049 % + 25 µA 1 kHz do 10 kHz od 20,2 mA do 202 mA CMC 0,50 % + 43 µA 10 Hz do 45 Hz od 0,202 A do 2,02 A CMC 0,19 % + 0,36 mA 45 Hz do 1 kHz od 0,202 A do 2,02 A CMC 0,064 % + 0,28 mA 1 kHz do 5 kHz od 0,202 A do 2,02 A CMC 0,50 % + 0,45 mA 30 Hz do 45 Hz od 2,02 A do 30 A CMC 0,19 % + 3,5 mA 45 Hz do 100 Hz od 2,02 A do 30 A CMC 0,059 % + 2,5 mA 100 Hz do 1 kHz od 2,02 A do 30 A CMC 0,50 % + 4,3 mA Stridavy proud / Meridla stridaveho proudu Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru nebo porovnani s etalonovym multimetrem 10 Hz az 45 Hz 10 µA az 202 µA CMC 0,20 % + 0,25 µA 45 Hz az 1 kHz 10 µA az 202 µA CMC 0,071 % + 0,15 µA 1 kHz az 10 kHz 10 µA az 202 µA CMC 0,96 % + 0,20 µA 10 Hz az 45 Hz 0,202 mA az 2,02 mA CMC 0,19 % + 0,31 µA 45 Hz az 1 kHz 0,202 mA az 2,02 mA CMC 0,055 % + 0,27 µA 1 kHz az 10 kHz 0,202 mA az 2,02 mA CMC 0,50 % + 0,35 µA 10 Hz az 45 Hz 2,02 mA az 20,2 mA CMC 0,19 % + 4,1 µA 45 Hz az 1 kHz 2,02 mA az 20,2 mA CMC 0,048 % + 2,5 µA 1 kHz az 10 kHz 2,02 mA az 20,2 mA CMC 0,25 % + 3,4 µA 10 Hz az 45 Hz 20,2 mA az 202 mA CMC 0,19 % + 41 µA 45 Hz az 1 kHz 20,2 mA az 202 mA CMC 0,049 % + 25 µA 1 kHz az 10 kHz 20,2 mA az 202 mA CMC 0,50 % + 43 µA 10 Hz az 45 Hz 0,202 A az 2,02 A CMC 0,19 % + 0,36 mA 45 Hz az 1 kHz 0,202 A az 2,02 A CMC 0,064 % + 0,28 mA 1 kHz az 5 kHz 0,202 A az 2,02 A CMC 0,50 % + 0,45 mA 30 Hz az 45 Hz 2,02 A az 30 A CMC 0,19 % + 3,5 mA 45 Hz az 100 Hz 2,02 A az 30 A CMC 0,059 % + 2,5 mA 100 Hz az 1 kHz 2,02 A az 30 A CMC 0,50 % + 4,3 mA KP-PB-113","search_en":"AC current / AC current meters Calibration – electrical quantities Direct measurement on a reference calibrator or comparison with a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator or comparison with a reference multimeter 10 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 10 kHz 10 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 10 kHz 10 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 10 kHz 10 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 10 kHz 10 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 5 kHz 30 Hz to 45 Hz 45 Hz to 100 Hz 100 Hz to 1 kHz KP-PB-113","search_zh":"交流电流 / 交流电流测量仪器 校准 – 电学量 在标准校准器上直接测量或与标准万用表比较 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在标准校准器上直接测量或与标准万用表比较 10 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 10 kHz 10 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 10 kHz 10 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 10 kHz 10 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 10 kHz 10 Hz 至 45 Hz 45 Hz 至 1 kHz 1 kHz 至 5 kHz 30 Hz 至 45 Hz 45 Hz 至 100 Hz 100 Hz 至 1 kHz KP-PB-113","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"10 Hz bis 45 Hz","range":"von 10 µA bis 202 µA","cmc":"0,20 % + 0,25 µA"},{"name":"45 Hz bis 1 kHz","range":"von 10 µA bis 202 µA","cmc":"0,071 % + 0,15 µA"},{"name":"1 kHz bis 10 kHz","range":"von 10 µA bis 202 µA","cmc":"0,96 % + 0,20 µA"},{"name":"10 Hz bis 45 Hz","range":"von 0,202 mA bis 2,02 mA","cmc":"0,19 % + 0,31 µA"},{"name":"45 Hz bis 1 kHz","range":"von 0,202 mA bis 2,02 mA","cmc":"0,055 % + 0,27 µA"},{"name":"1 kHz bis 10 kHz","range":"von 0,202 mA bis 2,02 mA","cmc":"0,50 % + 0,35 µA"},{"name":"10 Hz bis 45 Hz","range":"von 2,02 mA bis 20,2 mA","cmc":"0,19 % + 4,1 µA"},{"name":"45 Hz bis 1 kHz","range":"von 2,02 mA bis 20,2 mA","cmc":"0,048 % + 2,5 µA"},{"name":"1 kHz bis 10 kHz","range":"von 2,02 mA bis 20,2 mA","cmc":"0,25 % + 3,4 µA"},{"name":"10 Hz bis 45 Hz","range":"von 20,2 mA bis 202 mA","cmc":"0,19 % + 41 µA"},{"name":"45 Hz bis 1 kHz","range":"von 20,2 mA bis 202 mA","cmc":"0,049 % + 25 µA"},{"name":"1 kHz bis 10 kHz","range":"von 20,2 mA bis 202 mA","cmc":"0,50 % + 43 µA"},{"name":"10 Hz bis 45 Hz","range":"von 0,202 A bis 2,02 A","cmc":"0,19 % + 0,36 mA"},{"name":"45 Hz bis 1 kHz","range":"von 0,202 A bis 2,02 A","cmc":"0,064 % + 0,28 mA"},{"name":"1 kHz bis 5 kHz","range":"von 0,202 A bis 2,02 A","cmc":"0,50 % + 0,45 mA"},{"name":"30 Hz bis 45 Hz","range":"von 2,02 A bis 30 A","cmc":"0,19 % + 3,5 mA"},{"name":"45 Hz bis 100 Hz","range":"von 2,02 A bis 30 A","cmc":"0,059 % + 2,5 mA"},{"name":"100 Hz bis 1 kHz","range":"von 2,02 A bis 30 A","cmc":"0,50 % + 4,3 mA"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Wechselstrom / Wechselstrommessgeräte Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter 10 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 10 kHz 10 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 10 kHz 10 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 10 kHz 10 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 10 kHz 10 Hz bis 45 Hz 45 Hz bis 1 kHz 1 kHz bis 5 kHz 30 Hz bis 45 Hz 45 Hz bis 100 Hz 100 Hz bis 1 kHz KP-PB-113","technique_de":"Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter","techniques_de":["Direkte Messung am Referenzkalibrator oder Vergleich mit einem Referenzmultimeter"],"test_object_de":"Wechselstrom / Wechselstrommessgeräte"},{"_id":"0e7943302b759f7295dae86b","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / przyrządy do pomiaru prądu przemiennego","test_object_en":"AC current / AC current meters","test_object_zh":"交流电流 / 交流电流测量仪器","test_object_cs":"Střídavý proud / Měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"30 do 60 Hz","range":"od 30 A do 60 A","cmc":"0,43 % + 0,07 A"},{"name":"30 do 60 Hz","range":"od 60 A do 300 A","cmc":"0,50 % + 0,07 A"},{"name":"30 do 60 Hz","range":"od 300 A do 1500 A","cmc":"0,48 % + 0,08 A"}],"parameters_en":[{"name":"30 to 60 Hz","range":"30 A to 60 A","cmc":"0,43 % + 0,07 A"},{"name":"30 to 60 Hz","range":"60 A to 300 A","cmc":"0,50 % + 0,07 A"},{"name":"30 to 60 Hz","range":"300 A to 1500 A","cmc":"0,48 % + 0,08 A"}],"parameters_zh":[{"name":"30 至 60 Hz","range":"30 A 至 60 A","cmc":"0,43 % + 0,07 A"},{"name":"30 至 60 Hz","range":"60 A 至 300 A","cmc":"0,50 % + 0,07 A"},{"name":"30 至 60 Hz","range":"300 A 至 1500 A","cmc":"0,48 % + 0,08 A"}],"parameters_cs":[{"name":"30 až 60 Hz","range":"30 A až 60 A","cmc":"0,43 % + 0,07 A"},{"name":"30 až 60 Hz","range":"60 A až 300 A","cmc":"0,50 % + 0,07 A"},{"name":"30 až 60 Hz","range":"300 A až 1500 A","cmc":"0,48 % + 0,08 A"}],"technique":"Pomiar prądu symulowanego kalibratorem z cewką prądową","technique_en":"Measurement of a current simulated by a calibrator with current coil","technique_zh":"测量由带电流线圈的校准器模拟的电流","technique_cs":"Měření proudu simulovaného kalibrátorem s proudovou cívkou","techniques":["Pomiar prądu symulowanego kalibratorem z cewką prądową"],"techniques_en":["Measurement of a current simulated by a calibrator with current coil"],"techniques_zh":["测量由带电流线圈的校准器模拟的电流"],"techniques_cs":["Měření proudu simulovaného kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n30 do 60 Hz od 30 A do 60 A CMC 0,43 % + 0,07 A\n30 do 60 Hz od 60 A do 300 A CMC 0,50 % + 0,07 A\n30 do 60 Hz od 300 A do 1500 A CMC 0,48 % + 0,08 A\nPomiar prądu symulowanego kalibratorem z cewką prądową","reference":"KP-PB-113","norm_bases":["KP-PB-113"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar prądu symulowanego kalibratorem z cewką prądową 30 do 60 Hz od 30 A do 60 A CMC 0,43 % + 0,07 A 30 do 60 Hz od 60 A do 300 A CMC 0,50 % + 0,07 A 30 do 60 Hz od 300 A do 1500 A CMC 0,48 % + 0,08 A Střídavý proud / Měřidla střídavého proudu Kalibrace – elektrické veličiny Měření proudu simulovaného kalibrátorem s proudovou cívkou 30 až 60 Hz 30 A až 60 A CMC 0,43 % + 0,07 A 30 až 60 Hz 60 A až 300 A CMC 0,50 % + 0,07 A 30 až 60 Hz 300 A až 1500 A CMC 0,48 % + 0,08 A KP-PB-113 Prad przemienny / przyrzady do pomiaru pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar pradu symulowanego kalibratorem z cewka pradowa 30 do 60 Hz od 30 A do 60 A CMC 0,43 % + 0,07 A 30 do 60 Hz od 60 A do 300 A CMC 0,50 % + 0,07 A 30 do 60 Hz od 300 A do 1500 A CMC 0,48 % + 0,08 A Stridavy proud / Meridla stridaveho proudu Kalibrace – elektricke veliciny Mereni proudu simulovaneho kalibratorem s proudovou civkou 30 az 60 Hz 30 A az 60 A CMC 0,43 % + 0,07 A 30 az 60 Hz 60 A az 300 A CMC 0,50 % + 0,07 A 30 az 60 Hz 300 A az 1500 A CMC 0,48 % + 0,08 A KP-PB-113","search_en":"AC current / AC current meters Calibration – electrical quantities Measurement of a current simulated by a calibrator with current coil Uherský Brod II CMC for the field of measured quantity: Electrical quantities Measurement of a current simulated by a calibrator with current coil 30 to 60 Hz 30 to 60 Hz 30 to 60 Hz KP-PB-113","search_zh":"交流电流 / 交流电流测量仪器 校准 – 电学量 测量由带电流线圈的校准器模拟的电流 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 测量由带电流线圈的校准器模拟的电流 30 至 60 Hz 30 至 60 Hz 30 至 60 Hz KP-PB-113","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"30 bis 60 Hz","range":"von 30 A bis 60 A","cmc":"0,43 % + 0,07 A"},{"name":"30 bis 60 Hz","range":"von 60 A bis 300 A","cmc":"0,50 % + 0,07 A"},{"name":"30 bis 60 Hz","range":"von 300 A bis 1500 A","cmc":"0,48 % + 0,08 A"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Wechselstrom / Wechselstrommessgeräte Kalibrierung – elektrische Größen Messung eines mit dem Kalibrator mit Stromspule simulierten Stroms Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Messung eines mit dem Kalibrator mit Stromspule simulierten Stroms 30 bis 60 Hz 30 bis 60 Hz 30 bis 60 Hz KP-PB-113","technique_de":"Messung eines mit dem Kalibrator mit Stromspule simulierten Stroms","techniques_de":["Messung eines mit dem Kalibrator mit Stromspule simulierten Stroms"],"test_object_de":"Wechselstrom / Wechselstrommessgeräte"},{"_id":"fb5adce672266abf5b54f65d","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / rezystory i dekady rezystancyjne","test_object_en":"DC resistance / Resistors and resistance boxes","test_object_zh":"直流电阻 / 电阻器和电阻箱","test_object_cs":"Stejnosměrný odpor / Odpory a odporové dekády","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 1 Ω","cmc":"20 µΩ/Ω + 6,1 µΩ"},{"name":"","range":"od 1 Ω do 10 Ω","cmc":"11 µΩ/Ω + 31 µΩ"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"10 µΩ/Ω + 0,10 mΩ"},{"name":"","range":"od 100 Ω do 1 kΩ","cmc":"9,1 µΩ/Ω + 0,81 mΩ"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"11 µΩ/Ω + 8,1 mΩ"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"12 µΩ/Ω + 81 mΩ"},{"name":"","range":"od 0,1 MΩ do 1 MΩ","cmc":"13 µΩ/Ω + 2 Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"18 µΩ/Ω + 80 Ω"},{"name":"","range":"od 10 MΩ do 90 MΩ","cmc":"0,019 %"},{"name":"","range":"od 90 MΩ do 900 MΩ","cmc":"0,051 %"},{"name":"","range":"od 0,9 GΩ do 9 GΩ","cmc":"0,20 %"},{"name":"","range":"od 9 GΩ do 2000 GΩ","cmc":"2,5 %"}],"parameters_en":[{"name":"","range":"from 0 Ω to 1 Ω","cmc":"20 µΩ/Ω + 6,1 µΩ"},{"name":"","range":"from 1 Ω to 10 Ω","cmc":"11 µΩ/Ω + 31 µΩ"},{"name":"","range":"from 10 Ω to 100 Ω","cmc":"10 µΩ/Ω + 0,10 mΩ"},{"name":"","range":"from 100 Ω to 1 kΩ","cmc":"9,1 µΩ/Ω + 0,81 mΩ"},{"name":"","range":"from 1 kΩ to 10 kΩ","cmc":"11 µΩ/Ω + 8,1 mΩ"},{"name":"","range":"from 10 kΩ to 100 kΩ","cmc":"12 µΩ/Ω + 81 mΩ"},{"name":"","range":"from 0,1 MΩ to 1 MΩ","cmc":"13 µΩ/Ω + 2 Ω"},{"name":"","range":"from 1 MΩ to 10 MΩ","cmc":"18 µΩ/Ω + 80 Ω"},{"name":"","range":"from 10 MΩ to 90 MΩ","cmc":"0,019 %"},{"name":"","range":"from 90 MΩ to 900 MΩ","cmc":"0,051 %"},{"name":"","range":"0,9 GΩ to 9 GΩ","cmc":"0,20 %"},{"name":"","range":"9 GΩ to 2000 GΩ","cmc":"2,5 %"}],"parameters_zh":[{"name":"","range":"0 Ω 至 1 Ω","cmc":"20 µΩ/Ω + 6,1 µΩ"},{"name":"","range":"1 Ω 至 10 Ω","cmc":"11 µΩ/Ω + 31 µΩ"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"10 µΩ/Ω + 0,10 mΩ"},{"name":"","range":"100 Ω 至 1 kΩ","cmc":"9,1 µΩ/Ω + 0,81 mΩ"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"11 µΩ/Ω + 8,1 mΩ"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"12 µΩ/Ω + 81 mΩ"},{"name":"","range":"0,1 MΩ 至 1 MΩ","cmc":"13 µΩ/Ω + 2 Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"18 µΩ/Ω + 80 Ω"},{"name":"","range":"10 MΩ 至 90 MΩ","cmc":"0,019 %"},{"name":"","range":"90 MΩ 至 900 MΩ","cmc":"0,051 %"},{"name":"","range":"0,9 GΩ 至 9 GΩ","cmc":"0,20 %"},{"name":"","range":"9 GΩ 至 2000 GΩ","cmc":"2,5 %"}],"parameters_cs":[{"name":"","range":"0 Ω až 1 Ω","cmc":"20 µΩ/Ω + 6,1 µΩ"},{"name":"","range":"1 Ω až 10 Ω","cmc":"11 µΩ/Ω + 31 µΩ"},{"name":"","range":"10 Ω až 100 Ω","cmc":"10 µΩ/Ω + 0,10 mΩ"},{"name":"","range":"100 Ω až 1 kΩ","cmc":"9,1 µΩ/Ω + 0,81 mΩ"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"11 µΩ/Ω + 8,1 mΩ"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"12 µΩ/Ω + 81 mΩ"},{"name":"","range":"0,1 MΩ až 1 MΩ","cmc":"13 µΩ/Ω + 2 Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"18 µΩ/Ω + 80 Ω"},{"name":"","range":"10 MΩ až 90 MΩ","cmc":"0,019 %"},{"name":"","range":"90 MΩ až 900 MΩ","cmc":"0,051 %"},{"name":"","range":"0,9 GΩ až 9 GΩ","cmc":"0,20 %"},{"name":"","range":"9 GΩ až 2000 GΩ","cmc":"2,5 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 1 Ω CMC 20 µΩ/Ω + 6,1 µΩ\nod 1 Ω do 10 Ω CMC 11 µΩ/Ω + 31 µΩ\nod 10 Ω do 100 Ω CMC 10 µΩ/Ω + 0,10 mΩ\nod 100 Ω do 1 kΩ CMC 9,1 µΩ/Ω + 0,81 mΩ\nod 1 kΩ do 10 kΩ CMC 11 µΩ/Ω + 8,1 mΩ\nod 10 kΩ do 100 kΩ CMC 12 µΩ/Ω + 81 mΩ\nod 0,1 MΩ do 1 MΩ CMC 13 µΩ/Ω + 2 Ω\nod 1 MΩ do 10 MΩ CMC 18 µΩ/Ω + 80 Ω\nod 10 MΩ do 90 MΩ CMC 0,019 %\nod 90 MΩ do 900 MΩ CMC 0,051 %\nod 0,9 GΩ do 9 GΩ CMC 0,20 %\nod 9 GΩ do 2000 GΩ CMC 2,5 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP-PB-114","norm_bases":["KP-PB-114"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / rezystory i dekady rezystancyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 Ω do 1 Ω CMC 20 µΩ/Ω + 6,1 µΩ od 1 Ω do 10 Ω CMC 11 µΩ/Ω + 31 µΩ od 10 Ω do 100 Ω CMC 10 µΩ/Ω + 0,10 mΩ od 100 Ω do 1 kΩ CMC 9,1 µΩ/Ω + 0,81 mΩ od 1 kΩ do 10 kΩ CMC 11 µΩ/Ω + 8,1 mΩ od 10 kΩ do 100 kΩ CMC 12 µΩ/Ω + 81 mΩ od 0,1 MΩ do 1 MΩ CMC 13 µΩ/Ω + 2 Ω od 1 MΩ do 10 MΩ CMC 18 µΩ/Ω + 80 Ω od 10 MΩ do 90 MΩ CMC 0,019 % od 90 MΩ do 900 MΩ CMC 0,051 % od 0,9 GΩ do 9 GΩ CMC 0,20 % od 9 GΩ do 2000 GΩ CMC 2,5 % Stejnosměrný odpor / Odpory a odporové dekády Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 Ω až 1 Ω CMC 20 µΩ/Ω + 6,1 µΩ 1 Ω až 10 Ω CMC 11 µΩ/Ω + 31 µΩ 10 Ω až 100 Ω CMC 10 µΩ/Ω + 0,10 mΩ 100 Ω až 1 kΩ CMC 9,1 µΩ/Ω + 0,81 mΩ 1 kΩ až 10 kΩ CMC 11 µΩ/Ω + 8,1 mΩ 10 kΩ až 100 kΩ CMC 12 µΩ/Ω + 81 mΩ 0,1 MΩ až 1 MΩ CMC 13 µΩ/Ω + 2 Ω 1 MΩ až 10 MΩ CMC 18 µΩ/Ω + 80 Ω 10 MΩ až 90 MΩ CMC 0,019 % 90 MΩ až 900 MΩ CMC 0,051 % 0,9 GΩ až 9 GΩ CMC 0,20 % 9 GΩ až 2000 GΩ CMC 2,5 % KP-PB-114 Rezystancja przy pradzie stalym / rezystory i dekady rezystancyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 Ω do 1 Ω CMC 20 µΩ/Ω + 6,1 µΩ od 1 Ω do 10 Ω CMC 11 µΩ/Ω + 31 µΩ od 10 Ω do 100 Ω CMC 10 µΩ/Ω + 0,10 mΩ od 100 Ω do 1 kΩ CMC 9,1 µΩ/Ω + 0,81 mΩ od 1 kΩ do 10 kΩ CMC 11 µΩ/Ω + 8,1 mΩ od 10 kΩ do 100 kΩ CMC 12 µΩ/Ω + 81 mΩ od 0,1 MΩ do 1 MΩ CMC 13 µΩ/Ω + 2 Ω od 1 MΩ do 10 MΩ CMC 18 µΩ/Ω + 80 Ω od 10 MΩ do 90 MΩ CMC 0,019 % od 90 MΩ do 900 MΩ CMC 0,051 % od 0,9 GΩ do 9 GΩ CMC 0,20 % od 9 GΩ do 2000 GΩ CMC 2,5 % Stejnosmerny odpor / Odpory a odporove dekady Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 Ω az 1 Ω CMC 20 µΩ/Ω + 6,1 µΩ 1 Ω az 10 Ω CMC 11 µΩ/Ω + 31 µΩ 10 Ω az 100 Ω CMC 10 µΩ/Ω + 0,10 mΩ 100 Ω az 1 kΩ CMC 9,1 µΩ/Ω + 0,81 mΩ 1 kΩ az 10 kΩ CMC 11 µΩ/Ω + 8,1 mΩ 10 kΩ az 100 kΩ CMC 12 µΩ/Ω + 81 mΩ 0,1 MΩ az 1 MΩ CMC 13 µΩ/Ω + 2 Ω 1 MΩ az 10 MΩ CMC 18 µΩ/Ω + 80 Ω 10 MΩ az 90 MΩ CMC 0,019 % 90 MΩ az 900 MΩ CMC 0,051 % 0,9 GΩ az 9 GΩ CMC 0,20 % 9 GΩ az 2000 GΩ CMC 2,5 % KP-PB-114","search_en":"DC resistance / Resistors and resistance boxes Calibration – electrical quantities Direct measurement by a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement by a reference multimeter KP-PB-114","search_zh":"直流电阻 / 电阻器和电阻箱 校准 – 电学量 用标准万用表直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 用标准万用表直接测量 KP-PB-114","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 0 Ω bis 1 Ω","cmc":"20 µΩ/Ω + 6,1 µΩ"},{"name":"","range":"von 1 Ω bis 10 Ω","cmc":"11 µΩ/Ω + 31 µΩ"},{"name":"","range":"von 10 Ω bis 100 Ω","cmc":"10 µΩ/Ω + 0,10 mΩ"},{"name":"","range":"von 100 Ω bis 1 kΩ","cmc":"9,1 µΩ/Ω + 0,81 mΩ"},{"name":"","range":"von 1 kΩ bis 10 kΩ","cmc":"11 µΩ/Ω + 8,1 mΩ"},{"name":"","range":"von 10 kΩ bis 100 kΩ","cmc":"12 µΩ/Ω + 81 mΩ"},{"name":"","range":"von 0,1 MΩ bis 1 MΩ","cmc":"13 µΩ/Ω + 2 Ω"},{"name":"","range":"von 1 MΩ bis 10 MΩ","cmc":"18 µΩ/Ω + 80 Ω"},{"name":"","range":"von 10 MΩ bis 90 MΩ","cmc":"0,019 %"},{"name":"","range":"von 90 MΩ bis 900 MΩ","cmc":"0,051 %"},{"name":"","range":"von 0,9 GΩ bis 9 GΩ","cmc":"0,20 %"},{"name":"","range":"von 9 GΩ bis 2000 GΩ","cmc":"2,5 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstromwiderstand / Widerstände und Widerstandsdekaden Kalibrierung – elektrische Größen Direkte Messung mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung mit einem Referenzmultimeter KP-PB-114","technique_de":"Direkte Messung mit einem Referenzmultimeter","techniques_de":["Direkte Messung mit einem Referenzmultimeter"],"test_object_de":"Gleichstromwiderstand / Widerstände und Widerstandsdekaden"},{"_id":"126b8b637b15b76117e98556","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / przyrządy do pomiaru rezystancji","test_object_en":"DC resistance / DC resistance meters","test_object_zh":"直流电阻 / 直流电阻测量仪器","test_object_cs":"Stejnosměrný odpor / Měřidla stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0 Ω","cmc":"5,5 mΩ"},{"name":"","range":"0,0001 Ω","cmc":"0,0073 %"},{"name":"","range":"0,001 Ω","cmc":"0,0029 %"},{"name":"","range":"0,01 Ω","cmc":"0,0022 %"},{"name":"","range":"0,1 Ω","cmc":"0,0020 %"},{"name":"","range":"1 Ω","cmc":"0,0020 %"},{"name":"","range":"10 Ω","cmc":"0,0005 %"},{"name":"","range":"100 Ω","cmc":"0,0004 %"},{"name":"","range":"1 kΩ","cmc":"0,0039 %"},{"name":"","range":"10 kΩ","cmc":"0,0019 %"},{"name":"","range":"100 kΩ","cmc":"0,0031 %"},{"name":"","range":"1 MΩ","cmc":"0,0046 %"},{"name":"","range":"10 MΩ","cmc":"0,018 %"},{"name":"","range":"100 MΩ","cmc":"0,35 %"},{"name":"","range":"1 GΩ","cmc":"1,0 %"}],"parameters_en":[{"name":"","range":"0 Ω","cmc":"5,5 mΩ"},{"name":"","range":"0,0001 Ω","cmc":"0,0073 %"},{"name":"","range":"0,001 Ω","cmc":"0,0029 %"},{"name":"","range":"0,01 Ω","cmc":"0,0022 %"},{"name":"","range":"0,1 Ω","cmc":"0,0020 %"},{"name":"","range":"1 Ω","cmc":"0,0020 %"},{"name":"","range":"10 Ω","cmc":"0,0005 %"},{"name":"","range":"100 Ω","cmc":"0,0004 %"},{"name":"","range":"1 kΩ","cmc":"0,0039 %"},{"name":"","range":"10 kΩ","cmc":"0,0019 %"},{"name":"","range":"100 kΩ","cmc":"0,0031 %"},{"name":"","range":"1 MΩ","cmc":"0,0046 %"},{"name":"","range":"10 MΩ","cmc":"0,018 %"},{"name":"","range":"100 MΩ","cmc":"0,35 %"},{"name":"","range":"1 GΩ","cmc":"1,0 %"}],"parameters_zh":[{"name":"","range":"0 Ω","cmc":"5,5 mΩ"},{"name":"","range":"0,0001 Ω","cmc":"0,0073 %"},{"name":"","range":"0,001 Ω","cmc":"0,0029 %"},{"name":"","range":"0,01 Ω","cmc":"0,0022 %"},{"name":"","range":"0,1 Ω","cmc":"0,0020 %"},{"name":"","range":"1 Ω","cmc":"0,0020 %"},{"name":"","range":"10 Ω","cmc":"0,0005 %"},{"name":"","range":"100 Ω","cmc":"0,0004 %"},{"name":"","range":"1 kΩ","cmc":"0,0039 %"},{"name":"","range":"10 kΩ","cmc":"0,0019 %"},{"name":"","range":"100 kΩ","cmc":"0,0031 %"},{"name":"","range":"1 MΩ","cmc":"0,0046 %"},{"name":"","range":"10 MΩ","cmc":"0,018 %"},{"name":"","range":"100 MΩ","cmc":"0,35 %"},{"name":"","range":"1 GΩ","cmc":"1,0 %"}],"parameters_cs":[{"name":"","range":"0 Ω","cmc":"5,5 mΩ"},{"name":"","range":"0,0001 Ω","cmc":"0,0073 %"},{"name":"","range":"0,001 Ω","cmc":"0,0029 %"},{"name":"","range":"0,01 Ω","cmc":"0,0022 %"},{"name":"","range":"0,1 Ω","cmc":"0,0020 %"},{"name":"","range":"1 Ω","cmc":"0,0020 %"},{"name":"","range":"10 Ω","cmc":"0,0005 %"},{"name":"","range":"100 Ω","cmc":"0,0004 %"},{"name":"","range":"1 kΩ","cmc":"0,0039 %"},{"name":"","range":"10 kΩ","cmc":"0,0019 %"},{"name":"","range":"100 kΩ","cmc":"0,0031 %"},{"name":"","range":"1 MΩ","cmc":"0,0046 %"},{"name":"","range":"10 MΩ","cmc":"0,018 %"},{"name":"","range":"100 MΩ","cmc":"0,35 %"},{"name":"","range":"1 GΩ","cmc":"1,0 %"}],"technique":"Pomiar bezpośredni stałych wzorców rezystancji lub pomiar bezpośredni na kalibratorze, lub porównanie z multimetrem wzorcowym","technique_en":"Direct measurement of fixed resistance standards or direct measurement on a calibrator or comparison with a reference multimeter","technique_zh":"直接测量固定电阻标准器，或在校准器上直接测量，或与标准万用表比较","technique_cs":"Přímé měření fixních odporových etalonů nebo přímé měření na kalibrátoru nebo porovnání s etalonovým multimetrem","techniques":["Pomiar bezpośredni stałych wzorców rezystancji lub pomiar bezpośredni na kalibratorze, lub porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement of fixed resistance standards or direct measurement on a calibrator or comparison with a reference multimeter"],"techniques_zh":["直接测量固定电阻标准器，或在校准器上直接测量，或与标准万用表比较"],"techniques_cs":["Přímé měření fixních odporových etalonů nebo přímé měření na kalibrátoru nebo porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 Ω CMC 5,5 mΩ\n0,0001 Ω CMC 0,0073 %\n0,001 Ω CMC 0,0029 %\n0,01 Ω CMC 0,0022 %\n0,1 Ω CMC 0,0020 %\n1 Ω CMC 0,0020 %\n10 Ω CMC 0,0005 %\n100 Ω CMC 0,0004 %\n1 kΩ CMC 0,0039 %\n10 kΩ CMC 0,0019 %\n100 kΩ CMC 0,0031 %\n1 MΩ CMC 0,0046 %\n10 MΩ CMC 0,018 %\n100 MΩ CMC 0,35 %\n1 GΩ CMC 1,0 %\nPomiar bezpośredni stałych wzorców rezystancji lub pomiar bezpośredni na kalibratorze, lub porównanie z multimetrem wzorcowym","reference":"KP-PB-114","norm_bases":["KP-PB-114"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / przyrządy do pomiaru rezystancji Wzorcowanie – wielkości elektryczne Pomiar bezpośredni stałych wzorców rezystancji lub pomiar bezpośredni na kalibratorze, lub porównanie z multimetrem wzorcowym 0 Ω CMC 5,5 mΩ 0,0001 Ω CMC 0,0073 % 0,001 Ω CMC 0,0029 % 0,01 Ω CMC 0,0022 % 0,1 Ω CMC 0,0020 % 1 Ω CMC 0,0020 % 10 Ω CMC 0,0005 % 100 Ω CMC 0,0004 % 1 kΩ CMC 0,0039 % 10 kΩ CMC 0,0019 % 100 kΩ CMC 0,0031 % 1 MΩ CMC 0,0046 % 10 MΩ CMC 0,018 % 100 MΩ CMC 0,35 % 1 GΩ CMC 1,0 % Stejnosměrný odpor / Měřidla stejnosměrného odporu Kalibrace – elektrické veličiny Přímé měření fixních odporových etalonů nebo přímé měření na kalibrátoru nebo porovnání s etalonovým multimetrem 0 Ω CMC 5,5 mΩ 0,0001 Ω CMC 0,0073 % 0,001 Ω CMC 0,0029 % 0,01 Ω CMC 0,0022 % 0,1 Ω CMC 0,0020 % 1 Ω CMC 0,0020 % 10 Ω CMC 0,0005 % 100 Ω CMC 0,0004 % 1 kΩ CMC 0,0039 % 10 kΩ CMC 0,0019 % 100 kΩ CMC 0,0031 % 1 MΩ CMC 0,0046 % 10 MΩ CMC 0,018 % 100 MΩ CMC 0,35 % 1 GΩ CMC 1,0 % KP-PB-114 Rezystancja przy pradzie stalym / przyrzady do pomiaru rezystancji Wzorcowanie – wielkosci elektryczne Pomiar bezposredni stalych wzorcow rezystancji lub pomiar bezposredni na kalibratorze, lub porownanie z multimetrem wzorcowym 0 Ω CMC 5,5 mΩ 0,0001 Ω CMC 0,0073 % 0,001 Ω CMC 0,0029 % 0,01 Ω CMC 0,0022 % 0,1 Ω CMC 0,0020 % 1 Ω CMC 0,0020 % 10 Ω CMC 0,0005 % 100 Ω CMC 0,0004 % 1 kΩ CMC 0,0039 % 10 kΩ CMC 0,0019 % 100 kΩ CMC 0,0031 % 1 MΩ CMC 0,0046 % 10 MΩ CMC 0,018 % 100 MΩ CMC 0,35 % 1 GΩ CMC 1,0 % Stejnosmerny odpor / Meridla stejnosmerneho odporu Kalibrace – elektricke veliciny Prime mereni fixnich odporovych etalonu nebo prime mereni na kalibratoru nebo porovnani s etalonovym multimetrem 0 Ω CMC 5,5 mΩ 0,0001 Ω CMC 0,0073 % 0,001 Ω CMC 0,0029 % 0,01 Ω CMC 0,0022 % 0,1 Ω CMC 0,0020 % 1 Ω CMC 0,0020 % 10 Ω CMC 0,0005 % 100 Ω CMC 0,0004 % 1 kΩ CMC 0,0039 % 10 kΩ CMC 0,0019 % 100 kΩ CMC 0,0031 % 1 MΩ CMC 0,0046 % 10 MΩ CMC 0,018 % 100 MΩ CMC 0,35 % 1 GΩ CMC 1,0 % KP-PB-114","search_en":"DC resistance / DC resistance meters Calibration – electrical quantities Direct measurement of fixed resistance standards or direct measurement on a calibrator or comparison with a reference multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement of fixed resistance standards or direct measurement on a calibrator or comparison with a reference multimeter KP-PB-114","search_zh":"直流电阻 / 直流电阻测量仪器 校准 – 电学量 直接测量固定电阻标准器，或在校准器上直接测量，或与标准万用表比较 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 直接测量固定电阻标准器，或在校准器上直接测量，或与标准万用表比较 KP-PB-114","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstromwiderstand / Widerstandsmessgeräte Kalibrierung – elektrische Größen Direkte Messung fester Widerstandsnormale oder direkte Messung am Kalibrator oder Vergleich mit einem Referenzmultimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung fester Widerstandsnormale oder direkte Messung am Kalibrator oder Vergleich mit einem Referenzmultimeter KP-PB-114","technique_de":"Direkte Messung fester Widerstandsnormale oder direkte Messung am Kalibrator oder Vergleich mit einem Referenzmultimeter","techniques_de":["Direkte Messung fester Widerstandsnormale oder direkte Messung am Kalibrator oder Vergleich mit einem Referenzmultimeter"],"test_object_de":"Gleichstromwiderstand / Widerstandsmessgeräte"},{"_id":"bcbdb298e8b71be1669ab502","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / przyrządy do pomiaru rezystancji","test_object_en":"DC resistance / DC resistance meters","test_object_zh":"直流电阻 / 直流电阻测量仪器","test_object_cs":"Stejnosměrný odpor / Měřidla stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 1 kΩ","cmc":"0,020 % + 50 mΩ"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,020 % + 58 mΩ"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"0,020 % + 0,30 Ω"},{"name":"","range":"od 0,1 MΩ do 1 MΩ","cmc":"0,020 % + 4,0 Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,020 % +0,13 kΩ"}],"parameters_en":[{"name":"","range":"0 Ω to 1 kΩ","cmc":"0,020 % + 50 mΩ"},{"name":"","range":"from 1 kΩ to 10 kΩ","cmc":"0,020 % + 58 mΩ"},{"name":"","range":"from 10 kΩ to 100 kΩ","cmc":"0,020 % + 0,30 Ω"},{"name":"","range":"from 0,1 MΩ to 1 MΩ","cmc":"0,020 % + 4,0 Ω"},{"name":"","range":"from 1 MΩ to 10 MΩ","cmc":"0,020 % +0,13 kΩ"}],"parameters_zh":[{"name":"","range":"0 Ω 至 1 kΩ","cmc":"0,020 % + 50 mΩ"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,020 % + 58 mΩ"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"0,020 % + 0,30 Ω"},{"name":"","range":"0,1 MΩ 至 1 MΩ","cmc":"0,020 % + 4,0 Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,020 % +0,13 kΩ"}],"parameters_cs":[{"name":"","range":"0 Ω až 1 kΩ","cmc":"0,020 % + 50 mΩ"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,020 % + 58 mΩ"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"0,020 % + 0,30 Ω"},{"name":"","range":"0,1 MΩ až 1 MΩ","cmc":"0,020 % + 4,0 Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,020 % +0,13 kΩ"}],"technique":"Pomiar bezpośredni na kalibratorze","technique_en":"Direct measurement on a calibrator","technique_zh":"在校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru","techniques":["Pomiar bezpośredni na kalibratorze"],"techniques_en":["Direct measurement on a calibrator"],"techniques_zh":["在校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 1 kΩ CMC 0,020 % + 50 mΩ\nod 1 kΩ do 10 kΩ CMC 0,020 % + 58 mΩ\nod 10 kΩ do 100 kΩ CMC 0,020 % + 0,30 Ω\nod 0,1 MΩ do 1 MΩ CMC 0,020 % + 4,0 Ω\nod 1 MΩ do 10 MΩ CMC 0,020 % +0,13 kΩ\nPomiar bezpośredni na kalibratorze","reference":"KP-PB-114","norm_bases":["KP-PB-114"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / przyrządy do pomiaru rezystancji Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze od 0 Ω do 1 kΩ CMC 0,020 % + 50 mΩ od 1 kΩ do 10 kΩ CMC 0,020 % + 58 mΩ od 10 kΩ do 100 kΩ CMC 0,020 % + 0,30 Ω od 0,1 MΩ do 1 MΩ CMC 0,020 % + 4,0 Ω od 1 MΩ do 10 MΩ CMC 0,020 % +0,13 kΩ Stejnosměrný odpor / Měřidla stejnosměrného odporu Kalibrace – elektrické veličiny Přímé měření na kalibrátoru 0 Ω až 1 kΩ CMC 0,020 % + 50 mΩ 1 kΩ až 10 kΩ CMC 0,020 % + 58 mΩ 10 kΩ až 100 kΩ CMC 0,020 % + 0,30 Ω 0,1 MΩ až 1 MΩ CMC 0,020 % + 4,0 Ω 1 MΩ až 10 MΩ CMC 0,020 % +0,13 kΩ KP-PB-114 Rezystancja przy pradzie stalym / przyrzady do pomiaru rezystancji Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze od 0 Ω do 1 kΩ CMC 0,020 % + 50 mΩ od 1 kΩ do 10 kΩ CMC 0,020 % + 58 mΩ od 10 kΩ do 100 kΩ CMC 0,020 % + 0,30 Ω od 0,1 MΩ do 1 MΩ CMC 0,020 % + 4,0 Ω od 1 MΩ do 10 MΩ CMC 0,020 % +0,13 kΩ Stejnosmerny odpor / Meridla stejnosmerneho odporu Kalibrace – elektricke veliciny Prime mereni na kalibratoru 0 Ω az 1 kΩ CMC 0,020 % + 50 mΩ 1 kΩ az 10 kΩ CMC 0,020 % + 58 mΩ 10 kΩ az 100 kΩ CMC 0,020 % + 0,30 Ω 0,1 MΩ az 1 MΩ CMC 0,020 % + 4,0 Ω 1 MΩ az 10 MΩ CMC 0,020 % +0,13 kΩ KP-PB-114","search_en":"DC resistance / DC resistance meters Calibration – electrical quantities Direct measurement on a calibrator Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a calibrator KP-PB-114","search_zh":"直流电阻 / 直流电阻测量仪器 校准 – 电学量 在校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在校准器上直接测量 KP-PB-114","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 0 Ω bis 1 kΩ","cmc":"0,020 % + 50 mΩ"},{"name":"","range":"von 1 kΩ bis 10 kΩ","cmc":"0,020 % + 58 mΩ"},{"name":"","range":"von 10 kΩ bis 100 kΩ","cmc":"0,020 % + 0,30 Ω"},{"name":"","range":"von 0,1 MΩ bis 1 MΩ","cmc":"0,020 % + 4,0 Ω"},{"name":"","range":"von 1 MΩ bis 10 MΩ","cmc":"0,020 % +0,13 kΩ"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstromwiderstand / Widerstandsmessgeräte Kalibrierung – elektrische Größen Direkte Messung am Kalibrator Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Kalibrator KP-PB-114","technique_de":"Direkte Messung am Kalibrator","techniques_de":["Direkte Messung am Kalibrator"],"test_object_de":"Gleichstromwiderstand / Widerstandsmessgeräte"},{"_id":"ea18501e31339728915fd15e","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"6","test_object":"Rezystancja przy prądzie przemiennym / przyrządy do pomiaru rezystancji przy prądzie przemiennym","test_object_en":"AC resistance / AC resistance meters","test_object_zh":"交流电阻 / 交流电阻测量仪器","test_object_cs":"Střídavý odpor / Měřidla střídavého odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"10 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"10 Ω","cmc":"0,043 %"},{"name":"1 kHz","range":"50 Ω","cmc":"0,013 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"50 Ω","cmc":"0,021 %"},{"name":"100 kHz","range":"100 Ω","cmc":"0,021 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"1 kΩ","cmc":"0,021 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"10 kΩ","cmc":"0,041 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"100 kΩ","cmc":"0,12 %"},{"name":"1 kHz","range":"1 MΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"1 MΩ","cmc":"0,38 %"}],"parameters_en":[{"name":"1 kHz","range":"10 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"10 Ω","cmc":"0,043 %"},{"name":"1 kHz","range":"50 Ω","cmc":"0,013 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"50 Ω","cmc":"0,021 %"},{"name":"100 kHz","range":"100 Ω","cmc":"0,021 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"1 kΩ","cmc":"0,021 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"10 kΩ","cmc":"0,041 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"100 kΩ","cmc":"0,12 %"},{"name":"1 kHz","range":"1 MΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"1 MΩ","cmc":"0,38 %"}],"parameters_zh":[{"name":"1 kHz","range":"10 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"10 Ω","cmc":"0,043 %"},{"name":"1 kHz","range":"50 Ω","cmc":"0,013 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"50 Ω","cmc":"0,021 %"},{"name":"100 kHz","range":"100 Ω","cmc":"0,021 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"1 kΩ","cmc":"0,021 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"10 kΩ","cmc":"0,041 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"100 kΩ","cmc":"0,12 %"},{"name":"1 kHz","range":"1 MΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"1 MΩ","cmc":"0,38 %"}],"parameters_cs":[{"name":"1 kHz","range":"10 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"10 Ω","cmc":"0,043 %"},{"name":"1 kHz","range":"50 Ω","cmc":"0,013 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"50 Ω","cmc":"0,021 %"},{"name":"100 kHz","range":"100 Ω","cmc":"0,021 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"1 kΩ","cmc":"0,021 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"10 kΩ","cmc":"0,041 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"100 kΩ","cmc":"0,12 %"},{"name":"1 kHz","range":"1 MΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"1 MΩ","cmc":"0,38 %"}],"technique":"Pomiar bezpośredni na wzorcach rezystancji","technique_en":"Direct measurement on resistance standards","technique_zh":"在电阻标准器上直接测量","technique_cs":"Přímé měření na etalonech odporu","techniques":["Pomiar bezpośredni na wzorcach rezystancji"],"techniques_en":["Direct measurement on resistance standards"],"techniques_zh":["在电阻标准器上直接测量"],"techniques_cs":["Přímé měření na etalonech odporu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz 10 Ω CMC 0,013 %\n100 kHz 10 Ω CMC 0,043 %\n1 kHz 50 Ω CMC 0,013 %\n1 kHz 100 Ω CMC 0,013 %\n100 kHz 50 Ω CMC 0,021 %\n100 kHz 100 Ω CMC 0,021 %\n1 kHz 1 kΩ CMC 0,011 %\n100 kHz 1 kΩ CMC 0,021 %\n1 kHz 10 kΩ CMC 0,011 %\n100 kHz 10 kΩ CMC 0,041 %\n1 kHz 100 kΩ CMC 0,03 %\n100 kHz 100 kΩ CMC 0,12 %\n1 kHz 1 MΩ CMC 0,03 %\n100 kHz 1 MΩ CMC 0,38 %\nPomiar bezpośredni na wzorcach rezystancji","reference":"KP-PB-115","norm_bases":["KP-PB-115"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie przemiennym / przyrządy do pomiaru rezystancji przy prądzie przemiennym Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na wzorcach rezystancji 1 kHz 10 Ω CMC 0,013 % 100 kHz 10 Ω CMC 0,043 % 1 kHz 50 Ω CMC 0,013 % 1 kHz 100 Ω CMC 0,013 % 100 kHz 50 Ω CMC 0,021 % 100 kHz 100 Ω CMC 0,021 % 1 kHz 1 kΩ CMC 0,011 % 100 kHz 1 kΩ CMC 0,021 % 1 kHz 10 kΩ CMC 0,011 % 100 kHz 10 kΩ CMC 0,041 % 1 kHz 100 kΩ CMC 0,03 % 100 kHz 100 kΩ CMC 0,12 % 1 kHz 1 MΩ CMC 0,03 % 100 kHz 1 MΩ CMC 0,38 % Střídavý odpor / Měřidla střídavého odporu Kalibrace – elektrické veličiny Přímé měření na etalonech odporu 1 kHz 10 Ω CMC 0,013 % 100 kHz 10 Ω CMC 0,043 % 1 kHz 50 Ω CMC 0,013 % 1 kHz 100 Ω CMC 0,013 % 100 kHz 50 Ω CMC 0,021 % 100 kHz 100 Ω CMC 0,021 % 1 kHz 1 kΩ CMC 0,011 % 100 kHz 1 kΩ CMC 0,021 % 1 kHz 10 kΩ CMC 0,011 % 100 kHz 10 kΩ CMC 0,041 % 1 kHz 100 kΩ CMC 0,03 % 100 kHz 100 kΩ CMC 0,12 % 1 kHz 1 MΩ CMC 0,03 % 100 kHz 1 MΩ CMC 0,38 % KP-PB-115 Rezystancja przy pradzie przemiennym / przyrzady do pomiaru rezystancji przy pradzie przemiennym Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na wzorcach rezystancji 1 kHz 10 Ω CMC 0,013 % 100 kHz 10 Ω CMC 0,043 % 1 kHz 50 Ω CMC 0,013 % 1 kHz 100 Ω CMC 0,013 % 100 kHz 50 Ω CMC 0,021 % 100 kHz 100 Ω CMC 0,021 % 1 kHz 1 kΩ CMC 0,011 % 100 kHz 1 kΩ CMC 0,021 % 1 kHz 10 kΩ CMC 0,011 % 100 kHz 10 kΩ CMC 0,041 % 1 kHz 100 kΩ CMC 0,03 % 100 kHz 100 kΩ CMC 0,12 % 1 kHz 1 MΩ CMC 0,03 % 100 kHz 1 MΩ CMC 0,38 % Stridavy odpor / Meridla stridaveho odporu Kalibrace – elektricke veliciny Prime mereni na etalonech odporu 1 kHz 10 Ω CMC 0,013 % 100 kHz 10 Ω CMC 0,043 % 1 kHz 50 Ω CMC 0,013 % 1 kHz 100 Ω CMC 0,013 % 100 kHz 50 Ω CMC 0,021 % 100 kHz 100 Ω CMC 0,021 % 1 kHz 1 kΩ CMC 0,011 % 100 kHz 1 kΩ CMC 0,021 % 1 kHz 10 kΩ CMC 0,011 % 100 kHz 10 kΩ CMC 0,041 % 1 kHz 100 kΩ CMC 0,03 % 100 kHz 100 kΩ CMC 0,12 % 1 kHz 1 MΩ CMC 0,03 % 100 kHz 1 MΩ CMC 0,38 % KP-PB-115","search_en":"AC resistance / AC resistance meters Calibration – electrical quantities Direct measurement on resistance standards Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on resistance standards 1 kHz 100 kHz 1 kHz 1 kHz 100 kHz 100 kHz 1 kHz 100 kHz 1 kHz 100 kHz 1 kHz 100 kHz 1 kHz 100 kHz KP-PB-115","search_zh":"交流电阻 / 交流电阻测量仪器 校准 – 电学量 在电阻标准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在电阻标准器上直接测量 1 kHz 100 kHz 1 kHz 1 kHz 100 kHz 100 kHz 1 kHz 100 kHz 1 kHz 100 kHz 1 kHz 100 kHz 1 kHz 100 kHz KP-PB-115","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"1 kHz","range":"10 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"10 Ω","cmc":"0,043 %"},{"name":"1 kHz","range":"50 Ω","cmc":"0,013 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,013 %"},{"name":"100 kHz","range":"50 Ω","cmc":"0,021 %"},{"name":"100 kHz","range":"100 Ω","cmc":"0,021 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"1 kΩ","cmc":"0,021 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"100 kHz","range":"10 kΩ","cmc":"0,041 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"100 kΩ","cmc":"0,12 %"},{"name":"1 kHz","range":"1 MΩ","cmc":"0,03 %"},{"name":"100 kHz","range":"1 MΩ","cmc":"0,38 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Wechselstromwiderstand / Wechselstromwiderstandsmessgeräte Kalibrierung – elektrische Größen Direkte Messung an Widerstandsnormalen Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung an Widerstandsnormalen 1 kHz 100 kHz 1 kHz 1 kHz 100 kHz 100 kHz 1 kHz 100 kHz 1 kHz 100 kHz 1 kHz 100 kHz 1 kHz 100 kHz KP-PB-115","technique_de":"Direkte Messung an Widerstandsnormalen","techniques_de":["Direkte Messung an Widerstandsnormalen"],"test_object_de":"Wechselstromwiderstand / Wechselstromwiderstandsmessgeräte"},{"_id":"9de2eabfd5c6020bfb9117a2","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"7","test_object":"Moc prądu stałego / mierniki mocy prądu stałego (dla napięcia od 1 V do 1000 V i prądu od 0,5 mA do 30 A)","test_object_en":"DC Power / DC Power Meters (for voltage from 1 V to 1,000 V and current from 0.5 mA to 30 A)","test_object_zh":"直流功率 / 直流功率测量仪器（电压 1 V 至 1000 V，电流 0,5 mA 至 30 A）","test_object_cs":"Stejnosměrný výkon / Měřidla stejnosměrného výkonu (pro napětí 1 V až 1000 V a proud 0,5 mA až 30 A)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,5 mW do 30 kW","cmc":"0,072 %"}],"parameters_en":[{"name":"","range":"0,5 mW to 30 kW","cmc":"0,072 %"}],"parameters_zh":[{"name":"","range":"0,5 mW 至 30 kW","cmc":"0,072 %"}],"parameters_cs":[{"name":"","range":"0,5 mW až 30 kW","cmc":"0,072 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym","technique_en":"Direct measurement on a reference calibrator","technique_zh":"在标准校准器上直接测量","technique_cs":"Přímé měření na etalonovém kalibrátoru","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym"],"techniques_en":["Direct measurement on a reference calibrator"],"techniques_zh":["在标准校准器上直接测量"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 0,5 mW do 30 kW CMC 0,072 %\nPomiar bezpośredni na kalibratorze wzorcowym","reference":"KP-PB-123","norm_bases":["KP-PB-123"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / mierniki mocy prądu stałego (dla napięcia od 1 V do 1000 V i prądu od 0,5 mA do 30 A) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym od 0,5 mW do 30 kW CMC 0,072 % Stejnosměrný výkon / Měřidla stejnosměrného výkonu (pro napětí 1 V až 1000 V a proud 0,5 mA až 30 A) Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru 0,5 mW až 30 kW CMC 0,072 % KP-PB-123 Moc pradu stalego / mierniki mocy pradu stalego (dla napiecia od 1 V do 1000 V i pradu od 0,5 mA do 30 A) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym od 0,5 mW do 30 kW CMC 0,072 % Stejnosmerny vykon / Meridla stejnosmerneho vykonu (pro napeti 1 V az 1000 V a proud 0,5 mA az 30 A) Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru 0,5 mW az 30 kW CMC 0,072 % KP-PB-123","search_en":"DC Power / DC Power Meters (for voltage from 1 V to 1,000 V and current from 0.5 mA to 30 A) Calibration – electrical quantities Direct measurement on a reference calibrator Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator KP-PB-123","search_zh":"直流功率 / 直流功率测量仪器（电压 1 V 至 1000 V，电流 0,5 mA 至 30 A） 校准 – 电学量 在标准校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在标准校准器上直接测量 KP-PB-123","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 0,5 mW bis 30 kW","cmc":"0,072 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstromleistung / Gleichstromleistungsmessgeräte (für Spannungen von 1 V bis 1000 V und Ströme von 0,5 mA bis 30 A) Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator KP-PB-123","technique_de":"Direkte Messung am Referenzkalibrator","techniques_de":["Direkte Messung am Referenzkalibrator"],"test_object_de":"Gleichstromleistung / Gleichstromleistungsmessgeräte (für Spannungen von 1 V bis 1000 V und Ströme von 0,5 mA bis 30 A)"},{"_id":"a2ea44b79e4f482db650a2cc","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"7","test_object":"Moc prądu stałego / mierniki mocy prądu stałego (dla napięcia od 1 V do 1000 V i prądu od 30 A do 1500 A)","test_object_en":"DC Power / DC Power Meters (for voltage 1 V to 1,000 V and current 30 A to 1,500 A)","test_object_zh":"直流功率 / 直流功率测量仪器（电压 1 V 至 1000 V，电流 30 A 至 1500 A）","test_object_cs":"Stejnosměrný výkon / Měřidla stejnosměrného výkonu (pro napětí 1 V až 1000 V a proud 30 A až 1500 A)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 30 kW do 1500 kW","cmc":"0,74 %"}],"parameters_en":[{"name":"","range":"30 kW to 1500 kW","cmc":"0,74 %"}],"parameters_zh":[{"name":"","range":"30 kW 至 1500 kW","cmc":"0,74 %"}],"parameters_cs":[{"name":"","range":"30 kW až 1500 kW","cmc":"0,74 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym z cewką prądową","technique_en":"Direct measurement on a reference calibrator with current coil","technique_zh":"在带电流线圈的标准校准器上直接测量","technique_cs":"Přímé měření na etalonovém kalibrátoru s proudovou cívkou","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym z cewką prądową"],"techniques_en":["Direct measurement on a reference calibrator with current coil"],"techniques_zh":["在带电流线圈的标准校准器上直接测量"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 30 kW do 1500 kW CMC 0,74 %\nPomiar bezpośredni na kalibratorze wzorcowym z cewką prądową","reference":"KP-PB-123","norm_bases":["KP-PB-123"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / mierniki mocy prądu stałego (dla napięcia od 1 V do 1000 V i prądu od 30 A do 1500 A) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym z cewką prądową od 30 kW do 1500 kW CMC 0,74 % Stejnosměrný výkon / Měřidla stejnosměrného výkonu (pro napětí 1 V až 1000 V a proud 30 A až 1500 A) Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru s proudovou cívkou 30 kW až 1500 kW CMC 0,74 % KP-PB-123 Moc pradu stalego / mierniki mocy pradu stalego (dla napiecia od 1 V do 1000 V i pradu od 30 A do 1500 A) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym z cewka pradowa od 30 kW do 1500 kW CMC 0,74 % Stejnosmerny vykon / Meridla stejnosmerneho vykonu (pro napeti 1 V az 1000 V a proud 30 A az 1500 A) Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru s proudovou civkou 30 kW az 1500 kW CMC 0,74 % KP-PB-123","search_en":"DC Power / DC Power Meters (for voltage 1 V to 1,000 V and current 30 A to 1,500 A) Calibration – electrical quantities Direct measurement on a reference calibrator with current coil Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator with current coil KP-PB-123","search_zh":"直流功率 / 直流功率测量仪器（电压 1 V 至 1000 V，电流 30 A 至 1500 A） 校准 – 电学量 在带电流线圈的标准校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在带电流线圈的标准校准器上直接测量 KP-PB-123","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 30 kW bis 1500 kW","cmc":"0,74 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Gleichstromleistung / Gleichstromleistungsmessgeräte (für Spannungen von 1 V bis 1000 V und Ströme von 30 A bis 1500 A) Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator mit Stromspule Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator mit Stromspule KP-PB-123","technique_de":"Direkte Messung am Referenzkalibrator mit Stromspule","techniques_de":["Direkte Messung am Referenzkalibrator mit Stromspule"],"test_object_de":"Gleichstromleistung / Gleichstromleistungsmessgeräte (für Spannungen von 1 V bis 1000 V und Ströme von 30 A bis 1500 A)"},{"_id":"e48d1eb6ea64329d456f2cb6","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"8","test_object":"Jednofazowa moc czynna prądu przemiennego / mierniki mocy czynnej prądu przemiennego (dla napięcia od 1 V do 1000 V, prądu od 0,5 mA do 30 A i częstotliwości od 40 Hz do 400 Hz), pojemnościowa i indukcyjna","test_object_en":"AC active power single phase/ AC active power meters (for voltage from 1 V to 1,000 V and current from 0.5 mA to 30 A, frequency from 40 Hz to 400 Hz), capacitive and inductive","test_object_zh":"单相交流有功功率 / 交流有功功率测量仪器（电压 1 V 至 1000 V，电流 0,5 mA 至 30 A，频率 40 Hz 至 400 Hz），容性和感性","test_object_cs":"Střídavý činný výkon jednofázový/ Měřidla střídavého činného výkonu (pro napětí 1 V až 1000 V a proud 0,5 mA až 30 A, kmitočet 40 Hz až 400 Hz), kapacitní a induktivní","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"cos φ 1","range":"od 0,5 mW do 30 kW","cmc":"0,13 %"},{"name":"cos φ 0,8 do 0,9","range":"od 0,5 mW do 30 kW","cmc":"0,32 %"},{"name":"cos φ 0,7 do 0,8","range":"od 0,5 mW do 30 kW","cmc":"0,46 %"},{"name":"cos φ 0,6 do 0,7","range":"od 0,5 mW do 30 kW","cmc":"0,62 %"},{"name":"cos φ 0,5 do 0,6","range":"od 0,5 mW do 30 kW","cmc":"0,8 %"},{"name":"cos φ 0,4 do 0,5","range":"od 0,5 mW do 30 kW","cmc":"1,0 %"},{"name":"cos φ 0,3 do 0,4","range":"od 0,5 mW do 30 kW","cmc":"1,4 %"},{"name":"cos φ 0,2 do 0,3","range":"od 0,5 mW do 30 kW","cmc":"1,9 %"},{"name":"cos φ 0,1 do 0,2","range":"od 0,5 mW do 30 kW","cmc":"2,9 %"},{"name":"cos φ 0,1","range":"od 0,5 mW do 30 kW","cmc":"5,9 %"}],"parameters_en":[{"name":"cos φ 1","range":"0,5 mW to 30 kW","cmc":"0,13 %"},{"name":"cos φ 0.8 to 0.9","range":"0,5 mW to 30 kW","cmc":"0,32 %"},{"name":"cos φ 0.7 to 0.8","range":"0,5 mW to 30 kW","cmc":"0,46 %"},{"name":"cos φ 0.6 to 0.7","range":"0,5 mW to 30 kW","cmc":"0,62 %"},{"name":"cos φ 0.5 to 0.6","range":"0,5 mW to 30 kW","cmc":"0,8 %"},{"name":"cos φ 0.4 to 0.5","range":"0,5 mW to 30 kW","cmc":"1,0 %"},{"name":"cos φ 0.3 to 0.4","range":"0,5 mW to 30 kW","cmc":"1,4 %"},{"name":"cos φ 0.2 to 0.3","range":"0,5 mW to 30 kW","cmc":"1,9 %"},{"name":"cos φ 0.1 to 0.2","range":"0,5 mW to 30 kW","cmc":"2,9 %"},{"name":"cos φ 0.1","range":"0,5 mW to 30 kW","cmc":"5,9 %"}],"parameters_zh":[{"name":"功率因数 cos φ 1","range":"0,5 mW 至 30 kW","cmc":"0,13 %"},{"name":"功率因数 cos φ 0,8 至 0,9","range":"0,5 mW 至 30 kW","cmc":"0,32 %"},{"name":"功率因数 cos φ 0,7 至 0,8","range":"0,5 mW 至 30 kW","cmc":"0,46 %"},{"name":"功率因数 cos φ 0,6 至 0,7","range":"0,5 mW 至 30 kW","cmc":"0,62 %"},{"name":"功率因数 cos φ 0,5 至 0,6","range":"0,5 mW 至 30 kW","cmc":"0,8 %"},{"name":"功率因数 cos φ 0,4 至 0,5","range":"0,5 mW 至 30 kW","cmc":"1,0 %"},{"name":"功率因数 cos φ 0,3 至 0,4","range":"0,5 mW 至 30 kW","cmc":"1,4 %"},{"name":"功率因数 cos φ 0,2 至 0,3","range":"0,5 mW 至 30 kW","cmc":"1,9 %"},{"name":"功率因数 cos φ 0,1 至 0,2","range":"0,5 mW 至 30 kW","cmc":"2,9 %"},{"name":"功率因数 cos φ 0,1","range":"0,5 mW 至 30 kW","cmc":"5,9 %"}],"parameters_cs":[{"name":"cos φ 1","range":"0,5 mW až 30 kW","cmc":"0,13 %"},{"name":"cos φ 0,8 až 0,9","range":"0,5 mW až 30 kW","cmc":"0,32 %"},{"name":"cos φ 0,7 až 0,8","range":"0,5 mW až 30 kW","cmc":"0,46 %"},{"name":"cos φ 0,6 až 0,7","range":"0,5 mW až 30 kW","cmc":"0,62 %"},{"name":"cos φ 0,5 až 0,6","range":"0,5 mW až 30 kW","cmc":"0,8 %"},{"name":"cos φ 0,4 až 0,5","range":"0,5 mW až 30 kW","cmc":"1,0 %"},{"name":"cos φ 0,3 až 0,4","range":"0,5 mW až 30 kW","cmc":"1,4 %"},{"name":"cos φ 0,2 až 0,3","range":"0,5 mW až 30 kW","cmc":"1,9 %"},{"name":"cos φ 0,1 až 0,2","range":"0,5 mW až 30 kW","cmc":"2,9 %"},{"name":"cos φ 0,1","range":"0,5 mW až 30 kW","cmc":"5,9 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym","technique_en":"Direct measurement on a reference calibrator","technique_zh":"在标准校准器上直接测量","technique_cs":"Přímé měření na etalonovém kalibrátoru","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym"],"techniques_en":["Direct measurement on a reference calibrator"],"techniques_zh":["在标准校准器上直接测量"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\ncos φ 1 od 0,5 mW do 30 kW CMC 0,13 %\ncos φ 0,8 do 0,9 od 0,5 mW do 30 kW CMC 0,32 %\ncos φ 0,7 do 0,8 od 0,5 mW do 30 kW CMC 0,46 %\ncos φ 0,6 do 0,7 od 0,5 mW do 30 kW CMC 0,62 %\ncos φ 0,5 do 0,6 od 0,5 mW do 30 kW CMC 0,8 %\ncos φ 0,4 do 0,5 od 0,5 mW do 30 kW CMC 1,0 %\ncos φ 0,3 do 0,4 od 0,5 mW do 30 kW CMC 1,4 %\ncos φ 0,2 do 0,3 od 0,5 mW do 30 kW CMC 1,9 %\ncos φ 0,1 do 0,2 od 0,5 mW do 30 kW CMC 2,9 %\ncos φ 0,1 od 0,5 mW do 30 kW CMC 5,9 %\nPomiar bezpośredni na kalibratorze wzorcowym","reference":"KP-PB-123","norm_bases":["KP-PB-123"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Jednofazowa moc czynna prądu przemiennego / mierniki mocy czynnej prądu przemiennego (dla napięcia od 1 V do 1000 V, prądu od 0,5 mA do 30 A i częstotliwości od 40 Hz do 400 Hz), pojemnościowa i indukcyjna Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym cos φ 1 od 0,5 mW do 30 kW CMC 0,13 % cos φ 0,8 do 0,9 od 0,5 mW do 30 kW CMC 0,32 % cos φ 0,7 do 0,8 od 0,5 mW do 30 kW CMC 0,46 % cos φ 0,6 do 0,7 od 0,5 mW do 30 kW CMC 0,62 % cos φ 0,5 do 0,6 od 0,5 mW do 30 kW CMC 0,8 % cos φ 0,4 do 0,5 od 0,5 mW do 30 kW CMC 1,0 % cos φ 0,3 do 0,4 od 0,5 mW do 30 kW CMC 1,4 % cos φ 0,2 do 0,3 od 0,5 mW do 30 kW CMC 1,9 % cos φ 0,1 do 0,2 od 0,5 mW do 30 kW CMC 2,9 % cos φ 0,1 od 0,5 mW do 30 kW CMC 5,9 % Střídavý činný výkon jednofázový/ Měřidla střídavého činného výkonu (pro napětí 1 V až 1000 V a proud 0,5 mA až 30 A, kmitočet 40 Hz až 400 Hz), kapacitní a induktivní Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru cos φ 1 0,5 mW až 30 kW CMC 0,13 % cos φ 0,8 až 0,9 0,5 mW až 30 kW CMC 0,32 % cos φ 0,7 až 0,8 0,5 mW až 30 kW CMC 0,46 % cos φ 0,6 až 0,7 0,5 mW až 30 kW CMC 0,62 % cos φ 0,5 až 0,6 0,5 mW až 30 kW CMC 0,8 % cos φ 0,4 až 0,5 0,5 mW až 30 kW CMC 1,0 % cos φ 0,3 až 0,4 0,5 mW až 30 kW CMC 1,4 % cos φ 0,2 až 0,3 0,5 mW až 30 kW CMC 1,9 % cos φ 0,1 až 0,2 0,5 mW až 30 kW CMC 2,9 % cos φ 0,1 0,5 mW až 30 kW CMC 5,9 % KP-PB-123 Jednofazowa moc czynna pradu przemiennego / mierniki mocy czynnej pradu przemiennego (dla napiecia od 1 V do 1000 V, pradu od 0,5 mA do 30 A i czestotliwosci od 40 Hz do 400 Hz), pojemnosciowa i indukcyjna Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym cos φ 1 od 0,5 mW do 30 kW CMC 0,13 % cos φ 0,8 do 0,9 od 0,5 mW do 30 kW CMC 0,32 % cos φ 0,7 do 0,8 od 0,5 mW do 30 kW CMC 0,46 % cos φ 0,6 do 0,7 od 0,5 mW do 30 kW CMC 0,62 % cos φ 0,5 do 0,6 od 0,5 mW do 30 kW CMC 0,8 % cos φ 0,4 do 0,5 od 0,5 mW do 30 kW CMC 1,0 % cos φ 0,3 do 0,4 od 0,5 mW do 30 kW CMC 1,4 % cos φ 0,2 do 0,3 od 0,5 mW do 30 kW CMC 1,9 % cos φ 0,1 do 0,2 od 0,5 mW do 30 kW CMC 2,9 % cos φ 0,1 od 0,5 mW do 30 kW CMC 5,9 % Stridavy cinny vykon jednofazovy/ Meridla stridaveho cinneho vykonu (pro napeti 1 V az 1000 V a proud 0,5 mA az 30 A, kmitocet 40 Hz az 400 Hz), kapacitni a induktivni Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru cos φ 1 0,5 mW az 30 kW CMC 0,13 % cos φ 0,8 az 0,9 0,5 mW az 30 kW CMC 0,32 % cos φ 0,7 az 0,8 0,5 mW az 30 kW CMC 0,46 % cos φ 0,6 az 0,7 0,5 mW az 30 kW CMC 0,62 % cos φ 0,5 az 0,6 0,5 mW az 30 kW CMC 0,8 % cos φ 0,4 az 0,5 0,5 mW az 30 kW CMC 1,0 % cos φ 0,3 az 0,4 0,5 mW az 30 kW CMC 1,4 % cos φ 0,2 az 0,3 0,5 mW az 30 kW CMC 1,9 % cos φ 0,1 az 0,2 0,5 mW az 30 kW CMC 2,9 % cos φ 0,1 0,5 mW az 30 kW CMC 5,9 % KP-PB-123","search_en":"AC active power single phase/ AC active power meters (for voltage from 1 V to 1,000 V and current from 0.5 mA to 30 A, frequency from 40 Hz to 400 Hz), capacitive and inductive Calibration – electrical quantities Direct measurement on a reference calibrator Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator cos φ 1 cos φ 0.8 to 0.9 cos φ 0.7 to 0.8 cos φ 0.6 to 0.7 cos φ 0.5 to 0.6 cos φ 0.4 to 0.5 cos φ 0.3 to 0.4 cos φ 0.2 to 0.3 cos φ 0.1 to 0.2 cos φ 0.1 KP-PB-123","search_zh":"单相交流有功功率 / 交流有功功率测量仪器（电压 1 V 至 1000 V，电流 0,5 mA 至 30 A，频率 40 Hz 至 400 Hz），容性和感性 校准 – 电学量 在标准校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在标准校准器上直接测量 功率因数 cos φ 1 功率因数 cos φ 0,8 至 0,9 功率因数 cos φ 0,7 至 0,8 功率因数 cos φ 0,6 至 0,7 功率因数 cos φ 0,5 至 0,6 功率因数 cos φ 0,4 至 0,5 功率因数 cos φ 0,3 至 0,4 功率因数 cos φ 0,2 至 0,3 功率因数 cos φ 0,1 至 0,2 功率因数 cos φ 0,1 KP-PB-123","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":87,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"cos φ 1","range":"von 0,5 mW bis 30 kW","cmc":"0,13 %"},{"name":"cos φ 0,8 bis 0,9","range":"von 0,5 mW bis 30 kW","cmc":"0,32 %"},{"name":"cos φ 0,7 bis 0,8","range":"von 0,5 mW bis 30 kW","cmc":"0,46 %"},{"name":"cos φ 0,6 bis 0,7","range":"von 0,5 mW bis 30 kW","cmc":"0,62 %"},{"name":"cos φ 0,5 bis 0,6","range":"von 0,5 mW bis 30 kW","cmc":"0,8 %"},{"name":"cos φ 0,4 bis 0,5","range":"von 0,5 mW bis 30 kW","cmc":"1,0 %"},{"name":"cos φ 0,3 bis 0,4","range":"von 0,5 mW bis 30 kW","cmc":"1,4 %"},{"name":"cos φ 0,2 bis 0,3","range":"von 0,5 mW bis 30 kW","cmc":"1,9 %"},{"name":"cos φ 0,1 bis 0,2","range":"von 0,5 mW bis 30 kW","cmc":"2,9 %"},{"name":"cos φ 0,1","range":"von 0,5 mW bis 30 kW","cmc":"5,9 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Einphasige Wechselstrom-Wirkleistung / Wechselstrom-Wirkleistungsmessgeräte (für Spannungen von 1 V bis 1000 V, Ströme von 0,5 mA bis 30 A und Frequenzen von 40 Hz bis 400 Hz), kapazitiv und induktiv Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator cos φ 1 cos φ 0,8 bis 0,9 cos φ 0,7 bis 0,8 cos φ 0,6 bis 0,7 cos φ 0,5 bis 0,6 cos φ 0,4 bis 0,5 cos φ 0,3 bis 0,4 cos φ 0,2 bis 0,3 cos φ 0,1 bis 0,2 cos φ 0,1 KP-PB-123","technique_de":"Direkte Messung am Referenzkalibrator","techniques_de":["Direkte Messung am Referenzkalibrator"],"test_object_de":"Einphasige Wechselstrom-Wirkleistung / Wechselstrom-Wirkleistungsmessgeräte (für Spannungen von 1 V bis 1000 V, Ströme von 0,5 mA bis 30 A und Frequenzen von 40 Hz bis 400 Hz), kapazitiv und induktiv"},{"_id":"216932777ffeda152b1c61b1","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"8","test_object":"Jednofazowa moc czynna prądu przemiennego / mierniki mocy czynnej prądu przemiennego (dla napięcia od 1 V do 1000 V, prądu od 30 A do 1500 A i częstotliwości od 30 Hz do 60 Hz)","test_object_en":"AC active power single phase/ AC active power meters (for voltage 1 V to 1,000 V and current 30 A to 1,500 A, frequency 30 Hz to 60 Hz)","test_object_zh":"单相交流有功功率 / 交流有功功率测量仪器（电压 1 V 至 1000 V，电流 30 A 至 1500 A，频率 30 Hz 至 60 Hz）","test_object_cs":"Střídavý činný výkon jednofázový/ Měřidla střídavého činného výkonu (pro napětí 1 V až 1000 V a proud 30 A až 1500 A, kmitočet 30 Hz až 60 Hz)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"cos φ 1","range":"od 30 kW do 1500 kW","cmc":"0,95 %"}],"parameters_en":[{"name":"cos φ 1","range":"30 kW to 1500 kW","cmc":"0,95 %"}],"parameters_zh":[{"name":"功率因数 cos φ 1","range":"30 kW 至 1500 kW","cmc":"0,95 %"}],"parameters_cs":[{"name":"cos φ 1","range":"30 kW až 1500 kW","cmc":"0,95 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym z cewką prądową","technique_en":"Direct measurement on a reference calibrator with current coil","technique_zh":"在带电流线圈的标准校准器上直接测量","technique_cs":"Přímé měření na etalonovém kalibrátoru s proudovou cívkou","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym z cewką prądową"],"techniques_en":["Direct measurement on a reference calibrator with current coil"],"techniques_zh":["在带电流线圈的标准校准器上直接测量"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\ncos φ 1 od 30 kW do 1500 kW CMC 0,95 %\nPomiar bezpośredni na kalibratorze wzorcowym z cewką prądową","reference":"KP-PB-123","norm_bases":["KP-PB-123"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Jednofazowa moc czynna prądu przemiennego / mierniki mocy czynnej prądu przemiennego (dla napięcia od 1 V do 1000 V, prądu od 30 A do 1500 A i częstotliwości od 30 Hz do 60 Hz) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym z cewką prądową cos φ 1 od 30 kW do 1500 kW CMC 0,95 % Střídavý činný výkon jednofázový/ Měřidla střídavého činného výkonu (pro napětí 1 V až 1000 V a proud 30 A až 1500 A, kmitočet 30 Hz až 60 Hz) Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru s proudovou cívkou cos φ 1 30 kW až 1500 kW CMC 0,95 % KP-PB-123 Jednofazowa moc czynna pradu przemiennego / mierniki mocy czynnej pradu przemiennego (dla napiecia od 1 V do 1000 V, pradu od 30 A do 1500 A i czestotliwosci od 30 Hz do 60 Hz) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym z cewka pradowa cos φ 1 od 30 kW do 1500 kW CMC 0,95 % Stridavy cinny vykon jednofazovy/ Meridla stridaveho cinneho vykonu (pro napeti 1 V az 1000 V a proud 30 A az 1500 A, kmitocet 30 Hz az 60 Hz) Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru s proudovou civkou cos φ 1 30 kW az 1500 kW CMC 0,95 % KP-PB-123","search_en":"AC active power single phase/ AC active power meters (for voltage 1 V to 1,000 V and current 30 A to 1,500 A, frequency 30 Hz to 60 Hz) Calibration – electrical quantities Direct measurement on a reference calibrator with current coil Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator with current coil cos φ 1 KP-PB-123","search_zh":"单相交流有功功率 / 交流有功功率测量仪器（电压 1 V 至 1000 V，电流 30 A 至 1500 A，频率 30 Hz 至 60 Hz） 校准 – 电学量 在带电流线圈的标准校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在带电流线圈的标准校准器上直接测量 功率因数 cos φ 1 KP-PB-123","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":88,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"cos φ 1","range":"von 30 kW bis 1500 kW","cmc":"0,95 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Einphasige Wechselstrom-Wirkleistung / Wechselstrom-Wirkleistungsmessgeräte (für Spannungen von 1 V bis 1000 V, Ströme von 30 A bis 1500 A und Frequenzen von 30 Hz bis 60 Hz) Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator mit Stromspule Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator mit Stromspule cos φ 1 KP-PB-123","technique_de":"Direkte Messung am Referenzkalibrator mit Stromspule","techniques_de":["Direkte Messung am Referenzkalibrator mit Stromspule"],"test_object_de":"Einphasige Wechselstrom-Wirkleistung / Wechselstrom-Wirkleistungsmessgeräte (für Spannungen von 1 V bis 1000 V, Ströme von 30 A bis 1500 A und Frequenzen von 30 Hz bis 60 Hz)"},{"_id":"4cb5b1b2da56f9c4f2aacf2d","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"10","test_object":"Pojemność elektryczna / mierniki pojemności","test_object_en":"Capacity / Capacity meters","test_object_zh":"电容 / 电容测量仪器","test_object_cs":"Kapacita / Měřidla kapacity","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 1 kHz","range":"1 nF","cmc":"0,30 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,30 %"},{"name":"100 kHz","range":"10 nF","cmc":"1,5 %"},{"name":"10 Hz do 1 kHz","range":"20 nF","cmc":"0,30 %"},{"name":"10 Hz do 1 kHz","range":"50 nF","cmc":"0,30 %"},{"name":"10 Hz do 1 kHz","range":"100 nF","cmc":"0,30 %"},{"name":"10 Hz do 1 kHz","range":"1 µF","cmc":"0,49 %"},{"name":"10 Hz do 1 kHz","range":"10 µF","cmc":"0,72 %"},{"name":"1 kHz","range":"100 µF","cmc":"5,1 %"}],"parameters_en":[{"name":"10 Hz to 1 kHz","range":"1 nF","cmc":"0,30 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,30 %"},{"name":"100 kHz","range":"10 nF","cmc":"1,5 %"},{"name":"10 Hz to 1 kHz","range":"20 nF","cmc":"0,30 %"},{"name":"10 Hz to 1 kHz","range":"50 nF","cmc":"0,30 %"},{"name":"10 Hz to 1 kHz","range":"100 nF","cmc":"0,30 %"},{"name":"10 Hz to 1 kHz","range":"1 µF","cmc":"0,49 %"},{"name":"10 Hz to 1 kHz","range":"10 µF","cmc":"0,72 %"},{"name":"1 kHz","range":"100 µF","cmc":"5,1 %"}],"parameters_zh":[{"name":"10 Hz 至 1 kHz","range":"1 nF","cmc":"0,30 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,30 %"},{"name":"100 kHz","range":"10 nF","cmc":"1,5 %"},{"name":"10 Hz 至 1 kHz","range":"20 nF","cmc":"0,30 %"},{"name":"10 Hz 至 1 kHz","range":"50 nF","cmc":"0,30 %"},{"name":"10 Hz 至 1 kHz","range":"100 nF","cmc":"0,30 %"},{"name":"10 Hz 至 1 kHz","range":"1 µF","cmc":"0,49 %"},{"name":"10 Hz 至 1 kHz","range":"10 µF","cmc":"0,72 %"},{"name":"1 kHz","range":"100 µF","cmc":"5,1 %"}],"parameters_cs":[{"name":"10 Hz až 1 kHz","range":"1 nF","cmc":"0,30 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,30 %"},{"name":"100 kHz","range":"10 nF","cmc":"1,5 %"},{"name":"10 Hz až 1 kHz","range":"20 nF","cmc":"0,30 %"},{"name":"10 Hz až 1 kHz","range":"50 nF","cmc":"0,30 %"},{"name":"10 Hz až 1 kHz","range":"100 nF","cmc":"0,30 %"},{"name":"10 Hz až 1 kHz","range":"1 µF","cmc":"0,49 %"},{"name":"10 Hz až 1 kHz","range":"10 µF","cmc":"0,72 %"},{"name":"1 kHz","range":"100 µF","cmc":"5,1 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym lub pomiar bezpośredni na wzorcach pojemności","technique_en":"Direct measurement on a reference calibrator or direct measurement on capacity standards","technique_zh":"在标准校准器上直接测量或在电容标准器上直接测量","technique_cs":"Přímé měření na etalonovém kalibrátoru nebo přímé měření na etalonech kapacity","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym lub pomiar bezpośredni na wzorcach pojemności"],"techniques_en":["Direct measurement on a reference calibrator or direct measurement on capacity standards"],"techniques_zh":["在标准校准器上直接测量或在电容标准器上直接测量"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru nebo přímé měření na etalonech kapacity"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 1 kHz 1 nF CMC 0,30 %\n1 kHz 10 nF CMC 0,30 %\n100 kHz 10 nF CMC 1,5 %\n10 Hz do 1 kHz 20 nF CMC 0,30 %\n10 Hz do 1 kHz 50 nF CMC 0,30 %\n10 Hz do 1 kHz 100 nF CMC 0,30 %\n10 Hz do 1 kHz 1 µF CMC 0,49 %\n10 Hz do 1 kHz 10 µF CMC 0,72 %\n1 kHz 100 µF CMC 5,1 %\nPomiar bezpośredni na kalibratorze wzorcowym lub pomiar bezpośredni na wzorcach pojemności","reference":"KP-PB-115","norm_bases":["KP-PB-115"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność elektryczna / mierniki pojemności Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym lub pomiar bezpośredni na wzorcach pojemności 10 Hz do 1 kHz 1 nF CMC 0,30 % 1 kHz 10 nF CMC 0,30 % 100 kHz 10 nF CMC 1,5 % 10 Hz do 1 kHz 20 nF CMC 0,30 % 10 Hz do 1 kHz 50 nF CMC 0,30 % 10 Hz do 1 kHz 100 nF CMC 0,30 % 10 Hz do 1 kHz 1 µF CMC 0,49 % 10 Hz do 1 kHz 10 µF CMC 0,72 % 1 kHz 100 µF CMC 5,1 % Kapacita / Měřidla kapacity Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru nebo přímé měření na etalonech kapacity 10 Hz až 1 kHz 1 nF CMC 0,30 % 1 kHz 10 nF CMC 0,30 % 100 kHz 10 nF CMC 1,5 % 10 Hz až 1 kHz 20 nF CMC 0,30 % 10 Hz až 1 kHz 50 nF CMC 0,30 % 10 Hz až 1 kHz 100 nF CMC 0,30 % 10 Hz až 1 kHz 1 µF CMC 0,49 % 10 Hz až 1 kHz 10 µF CMC 0,72 % 1 kHz 100 µF CMC 5,1 % KP-PB-115 Pojemnosc elektryczna / mierniki pojemnosci Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym lub pomiar bezposredni na wzorcach pojemnosci 10 Hz do 1 kHz 1 nF CMC 0,30 % 1 kHz 10 nF CMC 0,30 % 100 kHz 10 nF CMC 1,5 % 10 Hz do 1 kHz 20 nF CMC 0,30 % 10 Hz do 1 kHz 50 nF CMC 0,30 % 10 Hz do 1 kHz 100 nF CMC 0,30 % 10 Hz do 1 kHz 1 µF CMC 0,49 % 10 Hz do 1 kHz 10 µF CMC 0,72 % 1 kHz 100 µF CMC 5,1 % Kapacita / Meridla kapacity Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru nebo prime mereni na etalonech kapacity 10 Hz az 1 kHz 1 nF CMC 0,30 % 1 kHz 10 nF CMC 0,30 % 100 kHz 10 nF CMC 1,5 % 10 Hz az 1 kHz 20 nF CMC 0,30 % 10 Hz az 1 kHz 50 nF CMC 0,30 % 10 Hz az 1 kHz 100 nF CMC 0,30 % 10 Hz az 1 kHz 1 µF CMC 0,49 % 10 Hz az 1 kHz 10 µF CMC 0,72 % 1 kHz 100 µF CMC 5,1 % KP-PB-115","search_en":"Capacity / Capacity meters Calibration – electrical quantities Direct measurement on a reference calibrator or direct measurement on capacity standards Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator or direct measurement on capacity standards 10 Hz to 1 kHz 1 kHz 100 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 1 kHz KP-PB-115","search_zh":"电容 / 电容测量仪器 校准 – 电学量 在标准校准器上直接测量或在电容标准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在标准校准器上直接测量或在电容标准器上直接测量 10 Hz 至 1 kHz 1 kHz 100 kHz 10 Hz 至 1 kHz 10 Hz 至 1 kHz 10 Hz 至 1 kHz 10 Hz 至 1 kHz 10 Hz 至 1 kHz 1 kHz KP-PB-115","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":89,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"10 Hz bis 1 kHz","range":"1 nF","cmc":"0,30 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,30 %"},{"name":"100 kHz","range":"10 nF","cmc":"1,5 %"},{"name":"10 Hz bis 1 kHz","range":"20 nF","cmc":"0,30 %"},{"name":"10 Hz bis 1 kHz","range":"50 nF","cmc":"0,30 %"},{"name":"10 Hz bis 1 kHz","range":"100 nF","cmc":"0,30 %"},{"name":"10 Hz bis 1 kHz","range":"1 µF","cmc":"0,49 %"},{"name":"10 Hz bis 1 kHz","range":"10 µF","cmc":"0,72 %"},{"name":"1 kHz","range":"100 µF","cmc":"5,1 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Elektrische Kapazität / Kapazitätsmessgeräte Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator oder direkte Messung an Kapazitätsnormalen Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator oder direkte Messung an Kapazitätsnormalen 10 Hz bis 1 kHz 1 kHz 100 kHz 10 Hz bis 1 kHz 10 Hz bis 1 kHz 10 Hz bis 1 kHz 10 Hz bis 1 kHz 10 Hz bis 1 kHz 1 kHz KP-PB-115","technique_de":"Direkte Messung am Referenzkalibrator oder direkte Messung an Kapazitätsnormalen","techniques_de":["Direkte Messung am Referenzkalibrator oder direkte Messung an Kapazitätsnormalen"],"test_object_de":"Elektrische Kapazität / Kapazitätsmessgeräte"},{"_id":"066a6e1cd1fa8b3704b167c7","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"12","test_object":"Indukcyjność / mierniki indukcyjności","test_object_en":"Inductance / Inductance meters","test_object_zh":"电感 / 电感测量仪器","test_object_cs":"Indukčnost / Měřidla indukčnosti","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"1 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"20 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"30 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"50 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"1 H","cmc":"0,67 %"},{"name":"1 kHz","range":"10 H","cmc":"0,78 %"}],"parameters_en":[{"name":"1 kHz","range":"1 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"20 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"30 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"50 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"1 H","cmc":"0,67 %"},{"name":"1 kHz","range":"10 H","cmc":"0,78 %"}],"parameters_zh":[{"name":"1 kHz","range":"1 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"20 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"30 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"50 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"1 H","cmc":"0,67 %"},{"name":"1 kHz","range":"10 H","cmc":"0,78 %"}],"parameters_cs":[{"name":"1 kHz","range":"1 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"20 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"30 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"50 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"1 H","cmc":"0,67 %"},{"name":"1 kHz","range":"10 H","cmc":"0,78 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym","technique_en":"Direct measurement on a reference calibrator","technique_zh":"在标准校准器上直接测量","technique_cs":"Přímé měření na etalonovém kalibrátoru","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym"],"techniques_en":["Direct measurement on a reference calibrator"],"techniques_zh":["在标准校准器上直接测量"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz 1 mH CMC 0,61 %\n1 kHz 10 mH CMC 0,61 %\n1 kHz 20 mH CMC 0,61 %\n1 kHz 30 mH CMC 0,61 %\n1 kHz 50 mH CMC 0,61 %\n1 kHz 100 mH CMC 0,61 %\n1 kHz 1 H CMC 0,67 %\n1 kHz 10 H CMC 0,78 %\nPomiar bezpośredni na kalibratorze wzorcowym","reference":"KP-PB-115","norm_bases":["KP-PB-115"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indukcyjność / mierniki indukcyjności Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym 1 kHz 1 mH CMC 0,61 % 1 kHz 10 mH CMC 0,61 % 1 kHz 20 mH CMC 0,61 % 1 kHz 30 mH CMC 0,61 % 1 kHz 50 mH CMC 0,61 % 1 kHz 100 mH CMC 0,61 % 1 kHz 1 H CMC 0,67 % 1 kHz 10 H CMC 0,78 % Indukčnost / Měřidla indukčnosti Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru 1 kHz 1 mH CMC 0,61 % 1 kHz 10 mH CMC 0,61 % 1 kHz 20 mH CMC 0,61 % 1 kHz 30 mH CMC 0,61 % 1 kHz 50 mH CMC 0,61 % 1 kHz 100 mH CMC 0,61 % 1 kHz 1 H CMC 0,67 % 1 kHz 10 H CMC 0,78 % KP-PB-115 Indukcyjnosc / mierniki indukcyjnosci Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym 1 kHz 1 mH CMC 0,61 % 1 kHz 10 mH CMC 0,61 % 1 kHz 20 mH CMC 0,61 % 1 kHz 30 mH CMC 0,61 % 1 kHz 50 mH CMC 0,61 % 1 kHz 100 mH CMC 0,61 % 1 kHz 1 H CMC 0,67 % 1 kHz 10 H CMC 0,78 % Indukcnost / Meridla indukcnosti Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru 1 kHz 1 mH CMC 0,61 % 1 kHz 10 mH CMC 0,61 % 1 kHz 20 mH CMC 0,61 % 1 kHz 30 mH CMC 0,61 % 1 kHz 50 mH CMC 0,61 % 1 kHz 100 mH CMC 0,61 % 1 kHz 1 H CMC 0,67 % 1 kHz 10 H CMC 0,78 % KP-PB-115","search_en":"Inductance / Inductance meters Calibration – electrical quantities Direct measurement on a reference calibrator Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a reference calibrator 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz KP-PB-115","search_zh":"电感 / 电感测量仪器 校准 – 电学量 在标准校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在标准校准器上直接测量 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz KP-PB-115","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":90,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"1 kHz","range":"1 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"20 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"30 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"50 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,61 %"},{"name":"1 kHz","range":"1 H","cmc":"0,67 %"},{"name":"1 kHz","range":"10 H","cmc":"0,78 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Induktivität / Induktivitätsmessgeräte Kalibrierung – elektrische Größen Direkte Messung am Referenzkalibrator Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Referenzkalibrator 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz KP-PB-115","technique_de":"Direkte Messung am Referenzkalibrator","techniques_de":["Direkte Messung am Referenzkalibrator"],"test_object_de":"Induktivität / Induktivitätsmessgeräte"},{"_id":"566055c7aae805560845788a","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"14","test_object":"Mierniki do badań instalacji elektrycznych / rezystancja izolacji","test_object_en":"Inspection equipment / Insulation resistance","test_object_zh":"电气安装检测仪 / 绝缘电阻","test_object_cs":"Revizní přístroje / Izolační odpor","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"Napięcie pomiarowe do 5000 V","range":"od 0,01 MΩ do 5 MΩ","cmc":"0,12 %"},{"name":"Napięcie pomiarowe do 5000 V","range":"od 5 MΩ do 121 MΩ","cmc":"0,22 %"},{"name":"Napięcie pomiarowe do 5000 V","range":"od 122 MΩ do 1,221 GΩ","cmc":"0,52 %"},{"name":"Napięcie pomiarowe do 5000 V","range":"od 1,22 GΩ do 12,221 GΩ","cmc":"1,2 %"}],"parameters_en":[{"name":"Measuring voltage up to 5,000 V","range":"0,01 MΩ to 5 MΩ","cmc":"0,12 %"},{"name":"Measuring voltage up to 5,000 V","range":"5 MΩ to 121 MΩ","cmc":"0,22 %"},{"name":"Measuring voltage up to 5,000 V","range":"122 MΩ to 1,221 GΩ","cmc":"0,52 %"},{"name":"Measuring voltage up to 5,000 V","range":"1,22 GΩ to 12,221 GΩ","cmc":"1,2 %"}],"parameters_zh":[{"name":"测量电压最高 5000 V","range":"0,01 MΩ 至 5 MΩ","cmc":"0,12 %"},{"name":"测量电压最高 5000 V","range":"5 MΩ 至 121 MΩ","cmc":"0,22 %"},{"name":"测量电压最高 5000 V","range":"122 MΩ 至 1,221 GΩ","cmc":"0,52 %"},{"name":"测量电压最高 5000 V","range":"1,22 GΩ 至 12,221 GΩ","cmc":"1,2 %"}],"parameters_cs":[{"name":"Měřicí napětí do 5000 V","range":"0,01 MΩ až 5 MΩ","cmc":"0,12 %"},{"name":"Měřicí napětí do 5000 V","range":"5 MΩ až 121 MΩ","cmc":"0,22 %"},{"name":"Měřicí napětí do 5000 V","range":"122 MΩ až 1,221 GΩ","cmc":"0,52 %"},{"name":"Měřicí napětí do 5000 V","range":"1,22 GΩ až 12,221 GΩ","cmc":"1,2 %"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych lub na wzorcowej dekadzie rezystancyjnej.","technique_en":"Direct measurement on a calibrator of inspection instruments or a reference resistance box","technique_zh":"在电气安装检测仪校准器或标准电阻箱上直接测量。","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů nebo etalonové odporové dekádě.","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych lub na wzorcowej dekadzie rezystancyjnej."],"techniques_en":["Direct measurement on a calibrator of inspection instruments or a reference resistance box"],"techniques_zh":["在电气安装检测仪校准器或标准电阻箱上直接测量。"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů nebo etalonové odporové dekádě."],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nNapięcie pomiarowe do 5000 V od 0,01 MΩ do 5 MΩ CMC 0,12 %\nNapięcie pomiarowe do 5000 V od 5 MΩ do 121 MΩ CMC 0,22 %\nNapięcie pomiarowe do 5000 V od 122 MΩ do 1,221 GΩ CMC 0,52 %\nNapięcie pomiarowe do 5000 V od 1,22 GΩ do 12,221 GΩ CMC 1,2 %\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych lub na wzorcowej dekadzie rezystancyjnej.","reference":"KP-PB-120","norm_bases":["KP-PB-120"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / rezystancja izolacji Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych lub na wzorcowej dekadzie rezystancyjnej. Napięcie pomiarowe do 5000 V od 0,01 MΩ do 5 MΩ CMC 0,12 % Napięcie pomiarowe do 5000 V od 5 MΩ do 121 MΩ CMC 0,22 % Napięcie pomiarowe do 5000 V od 122 MΩ do 1,221 GΩ CMC 0,52 % Napięcie pomiarowe do 5000 V od 1,22 GΩ do 12,221 GΩ CMC 1,2 % Revizní přístroje / Izolační odpor Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů nebo etalonové odporové dekádě. Měřicí napětí do 5000 V 0,01 MΩ až 5 MΩ CMC 0,12 % Měřicí napětí do 5000 V 5 MΩ až 121 MΩ CMC 0,22 % Měřicí napětí do 5000 V 122 MΩ až 1,221 GΩ CMC 0,52 % Měřicí napětí do 5000 V 1,22 GΩ až 12,221 GΩ CMC 1,2 % KP-PB-120 Mierniki do badan instalacji elektrycznych / rezystancja izolacji Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych lub na wzorcowej dekadzie rezystancyjnej. Napiecie pomiarowe do 5000 V od 0,01 MΩ do 5 MΩ CMC 0,12 % Napiecie pomiarowe do 5000 V od 5 MΩ do 121 MΩ CMC 0,22 % Napiecie pomiarowe do 5000 V od 122 MΩ do 1,221 GΩ CMC 0,52 % Napiecie pomiarowe do 5000 V od 1,22 GΩ do 12,221 GΩ CMC 1,2 % Revizni pristroje / Izolacni odpor Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju nebo etalonove odporove dekade. Merici napeti do 5000 V 0,01 MΩ az 5 MΩ CMC 0,12 % Merici napeti do 5000 V 5 MΩ az 121 MΩ CMC 0,22 % Merici napeti do 5000 V 122 MΩ az 1,221 GΩ CMC 0,52 % Merici napeti do 5000 V 1,22 GΩ az 12,221 GΩ CMC 1,2 % KP-PB-120","search_en":"Inspection equipment / Insulation resistance Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments or a reference resistance box Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a calibrator of inspection instruments or a reference resistance box Measuring voltage up to 5,000 V Measuring voltage up to 5,000 V Measuring voltage up to 5,000 V Measuring voltage up to 5,000 V KP-PB-120","search_zh":"电气安装检测仪 / 绝缘电阻 校准 – 电学量 在电气安装检测仪校准器或标准电阻箱上直接测量。 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在电气安装检测仪校准器或标准电阻箱上直接测量。 测量电压最高 5000 V 测量电压最高 5000 V 测量电压最高 5000 V 测量电压最高 5000 V KP-PB-120","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":91,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"Messspannung bis 5000 V","range":"von 0,01 MΩ bis 5 MΩ","cmc":"0,12 %"},{"name":"Messspannung bis 5000 V","range":"von 5 MΩ bis 121 MΩ","cmc":"0,22 %"},{"name":"Messspannung bis 5000 V","range":"von 122 MΩ bis 1,221 GΩ","cmc":"0,52 %"},{"name":"Messspannung bis 5000 V","range":"von 1,22 GΩ bis 12,221 GΩ","cmc":"1,2 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Prüfgeräte für elektrische Installationen / Isolationswiderstand Kalibrierung – elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen oder an einer Referenz-Widerstandsdekade. Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen oder an einer Referenz-Widerstandsdekade. Messspannung bis 5000 V Messspannung bis 5000 V Messspannung bis 5000 V Messspannung bis 5000 V KP-PB-120","technique_de":"Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen oder an einer Referenz-Widerstandsdekade.","techniques_de":["Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen oder an einer Referenz-Widerstandsdekade."],"test_object_de":"Prüfgeräte für elektrische Installationen / Isolationswiderstand"},{"_id":"2439d9805f01f3a36d90f61a","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"14","test_object":"Mierniki do badań instalacji elektrycznych / impedancja sieci przy 50 Hz","test_object_en":"Inspection equipment / Mains impedance at 50 Hz","test_object_zh":"电气安装检测仪 / 50 Hz 时的电网阻抗","test_object_cs":"Revizní přístroje / Impedance sítě při 50 Hz","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od Z₀= 0 Ω do 2 Ω","cmc":"20 mΩ"},{"name":"","range":"50 mΩ + Z₀","cmc":"2,4 mΩ"},{"name":"","range":"100 mΩ + Z₀","cmc":"3,8 mΩ"},{"name":"","range":"220 mΩ + Z₀","cmc":"6,6 mΩ"},{"name":"","range":"330 mΩ + Z₀","cmc":"9,6 mΩ"},{"name":"","range":"500 mΩ + Z₀","cmc":"12 mΩ"},{"name":"","range":"1 Ω + Z₀","cmc":"16 mΩ"},{"name":"","range":"5 Ω + Z₀","cmc":"32 mΩ"},{"name":"","range":"10 Ω + Z₀","cmc":"54 mΩ"},{"name":"","range":"100 Ω + Z₀","cmc":"0,50 Ω"},{"name":"","range":"1 kΩ + Z₀","cmc":"5,0 Ω"}],"parameters_en":[{"name":"","range":"Z₀= 0 Ω to 2 Ω","cmc":"20 mΩ"},{"name":"","range":"50 mΩ + Z₀","cmc":"2,4 mΩ"},{"name":"","range":"100 mΩ + Z₀","cmc":"3,8 mΩ"},{"name":"","range":"220 mΩ + Z₀","cmc":"6,6 mΩ"},{"name":"","range":"330 mΩ + Z₀","cmc":"9,6 mΩ"},{"name":"","range":"500 mΩ + Z₀","cmc":"12 mΩ"},{"name":"","range":"1 Ω + Z₀","cmc":"16 mΩ"},{"name":"","range":"5 Ω + Z₀","cmc":"32 mΩ"},{"name":"","range":"10 Ω + Z₀","cmc":"54 mΩ"},{"name":"","range":"100 Ω + Z₀","cmc":"0,50 Ω"},{"name":"","range":"1 kΩ + Z₀","cmc":"5,0 Ω"}],"parameters_zh":[{"name":"","range":"Z₀= 0 Ω 至 2 Ω","cmc":"20 mΩ"},{"name":"","range":"50 mΩ + Z₀","cmc":"2,4 mΩ"},{"name":"","range":"100 mΩ + Z₀","cmc":"3,8 mΩ"},{"name":"","range":"220 mΩ + Z₀","cmc":"6,6 mΩ"},{"name":"","range":"330 mΩ + Z₀","cmc":"9,6 mΩ"},{"name":"","range":"500 mΩ + Z₀","cmc":"12 mΩ"},{"name":"","range":"1 Ω + Z₀","cmc":"16 mΩ"},{"name":"","range":"5 Ω + Z₀","cmc":"32 mΩ"},{"name":"","range":"10 Ω + Z₀","cmc":"54 mΩ"},{"name":"","range":"100 Ω + Z₀","cmc":"0,50 Ω"},{"name":"","range":"1 kΩ + Z₀","cmc":"5,0 Ω"}],"parameters_cs":[{"name":"","range":"Z₀= 0 Ω až 2 Ω","cmc":"20 mΩ"},{"name":"","range":"50 mΩ + Z₀","cmc":"2,4 mΩ"},{"name":"","range":"100 mΩ + Z₀","cmc":"3,8 mΩ"},{"name":"","range":"220 mΩ + Z₀","cmc":"6,6 mΩ"},{"name":"","range":"330 mΩ + Z₀","cmc":"9,6 mΩ"},{"name":"","range":"500 mΩ + Z₀","cmc":"12 mΩ"},{"name":"","range":"1 Ω + Z₀","cmc":"16 mΩ"},{"name":"","range":"5 Ω + Z₀","cmc":"32 mΩ"},{"name":"","range":"10 Ω + Z₀","cmc":"54 mΩ"},{"name":"","range":"100 Ω + Z₀","cmc":"0,50 Ω"},{"name":"","range":"1 kΩ + Z₀","cmc":"5,0 Ω"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","technique_en":"Direct measurement on a calibrator of inspection instruments","technique_zh":"在电气安装检测仪校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych"],"techniques_en":["Direct measurement on a calibrator of inspection instruments"],"techniques_zh":["在电气安装检测仪校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod Z₀= 0 Ω do 2 Ω CMC 20 mΩ\n50 mΩ + Z₀ CMC 2,4 mΩ\n100 mΩ + Z₀ CMC 3,8 mΩ\n220 mΩ + Z₀ CMC 6,6 mΩ\n330 mΩ + Z₀ CMC 9,6 mΩ\n500 mΩ + Z₀ CMC 12 mΩ\n1 Ω + Z₀ CMC 16 mΩ\n5 Ω + Z₀ CMC 32 mΩ\n10 Ω + Z₀ CMC 54 mΩ\n100 Ω + Z₀ CMC 0,50 Ω\n1 kΩ + Z₀ CMC 5,0 Ω\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","reference":"KP-PB-120","norm_bases":["KP-PB-120"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / impedancja sieci przy 50 Hz Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych od Z₀= 0 Ω do 2 Ω CMC 20 mΩ 50 mΩ + Z₀ CMC 2,4 mΩ 100 mΩ + Z₀ CMC 3,8 mΩ 220 mΩ + Z₀ CMC 6,6 mΩ 330 mΩ + Z₀ CMC 9,6 mΩ 500 mΩ + Z₀ CMC 12 mΩ 1 Ω + Z₀ CMC 16 mΩ 5 Ω + Z₀ CMC 32 mΩ 10 Ω + Z₀ CMC 54 mΩ 100 Ω + Z₀ CMC 0,50 Ω 1 kΩ + Z₀ CMC 5,0 Ω Revizní přístroje / Impedance sítě při 50 Hz Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů Z₀= 0 Ω až 2 Ω CMC 20 mΩ 50 mΩ + Z₀ CMC 2,4 mΩ 100 mΩ + Z₀ CMC 3,8 mΩ 220 mΩ + Z₀ CMC 6,6 mΩ 330 mΩ + Z₀ CMC 9,6 mΩ 500 mΩ + Z₀ CMC 12 mΩ 1 Ω + Z₀ CMC 16 mΩ 5 Ω + Z₀ CMC 32 mΩ 10 Ω + Z₀ CMC 54 mΩ 100 Ω + Z₀ CMC 0,50 Ω 1 kΩ + Z₀ CMC 5,0 Ω KP-PB-120 Mierniki do badan instalacji elektrycznych / impedancja sieci przy 50 Hz Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych od Z₀= 0 Ω do 2 Ω CMC 20 mΩ 50 mΩ + Z₀ CMC 2,4 mΩ 100 mΩ + Z₀ CMC 3,8 mΩ 220 mΩ + Z₀ CMC 6,6 mΩ 330 mΩ + Z₀ CMC 9,6 mΩ 500 mΩ + Z₀ CMC 12 mΩ 1 Ω + Z₀ CMC 16 mΩ 5 Ω + Z₀ CMC 32 mΩ 10 Ω + Z₀ CMC 54 mΩ 100 Ω + Z₀ CMC 0,50 Ω 1 kΩ + Z₀ CMC 5,0 Ω Revizni pristroje / Impedance site pri 50 Hz Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju Z₀= 0 Ω az 2 Ω CMC 20 mΩ 50 mΩ + Z₀ CMC 2,4 mΩ 100 mΩ + Z₀ CMC 3,8 mΩ 220 mΩ + Z₀ CMC 6,6 mΩ 330 mΩ + Z₀ CMC 9,6 mΩ 500 mΩ + Z₀ CMC 12 mΩ 1 Ω + Z₀ CMC 16 mΩ 5 Ω + Z₀ CMC 32 mΩ 10 Ω + Z₀ CMC 54 mΩ 100 Ω + Z₀ CMC 0,50 Ω 1 kΩ + Z₀ CMC 5,0 Ω KP-PB-120","search_en":"Inspection equipment / Mains impedance at 50 Hz Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a calibrator of inspection instruments KP-PB-120","search_zh":"电气安装检测仪 / 50 Hz 时的电网阻抗 校准 – 电学量 在电气安装检测仪校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在电气安装检测仪校准器上直接测量 KP-PB-120","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":92,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von Z₀= 0 Ω bis 2 Ω","cmc":"20 mΩ"},{"name":"","range":"50 mΩ + Z₀","cmc":"2,4 mΩ"},{"name":"","range":"100 mΩ + Z₀","cmc":"3,8 mΩ"},{"name":"","range":"220 mΩ + Z₀","cmc":"6,6 mΩ"},{"name":"","range":"330 mΩ + Z₀","cmc":"9,6 mΩ"},{"name":"","range":"500 mΩ + Z₀","cmc":"12 mΩ"},{"name":"","range":"1 Ω + Z₀","cmc":"16 mΩ"},{"name":"","range":"5 Ω + Z₀","cmc":"32 mΩ"},{"name":"","range":"10 Ω + Z₀","cmc":"54 mΩ"},{"name":"","range":"100 Ω + Z₀","cmc":"0,50 Ω"},{"name":"","range":"1 kΩ + Z₀","cmc":"5,0 Ω"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Prüfgeräte für elektrische Installationen / Netzimpedanz bei 50 Hz Kalibrierung – elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen KP-PB-120","technique_de":"Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen","techniques_de":["Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen"],"test_object_de":"Prüfgeräte für elektrische Installationen / Netzimpedanz bei 50 Hz"},{"_id":"c59140c2cfa4203a82d40cf6","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"14","test_object":"Mierniki do badań instalacji elektrycznych / rezystancja przejścia","test_object_en":"Inspection equipment / Transient resistance","test_object_zh":"电气安装检测仪 / 过渡电阻","test_object_cs":"Revizní přístroje / Přechodový odpor","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"0,01 Ω","cmc":"0,60 %"},{"name":"50 Hz","range":"0,1 Ω","cmc":"0,20 %"},{"name":"50 Hz","range":"1 Ω","cmc":"0,011 %"}],"parameters_en":[{"name":"50 Hz","range":"0,01 Ω","cmc":"0,60 %"},{"name":"50 Hz","range":"0,1 Ω","cmc":"0,20 %"},{"name":"50 Hz","range":"1 Ω","cmc":"0,011 %"}],"parameters_zh":[{"name":"50 Hz","range":"0,01 Ω","cmc":"0,60 %"},{"name":"50 Hz","range":"0,1 Ω","cmc":"0,20 %"},{"name":"50 Hz","range":"1 Ω","cmc":"0,011 %"}],"parameters_cs":[{"name":"50 Hz","range":"0,01 Ω","cmc":"0,60 %"},{"name":"50 Hz","range":"0,1 Ω","cmc":"0,20 %"},{"name":"50 Hz","range":"1 Ω","cmc":"0,011 %"}],"technique":"Pomiar bezpośredni na wzorcach impedancji","technique_en":"Direct measurement on impedance standards","technique_zh":"在阻抗标准器上直接测量","technique_cs":"Přímé měření na etalonech impedance","techniques":["Pomiar bezpośredni na wzorcach impedancji"],"techniques_en":["Direct measurement on impedance standards"],"techniques_zh":["在阻抗标准器上直接测量"],"techniques_cs":["Přímé měření na etalonech impedance"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz 0,01 Ω CMC 0,60 %\n50 Hz 0,1 Ω CMC 0,20 %\n50 Hz 1 Ω CMC 0,011 %\nPomiar bezpośredni na wzorcach impedancji","reference":"KP-PB-120","norm_bases":["KP-PB-120"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / rezystancja przejścia Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na wzorcach impedancji 50 Hz 0,01 Ω CMC 0,60 % 50 Hz 0,1 Ω CMC 0,20 % 50 Hz 1 Ω CMC 0,011 % Revizní přístroje / Přechodový odpor Kalibrace – elektrické veličiny Přímé měření na etalonech impedance 50 Hz 0,01 Ω CMC 0,60 % 50 Hz 0,1 Ω CMC 0,20 % 50 Hz 1 Ω CMC 0,011 % KP-PB-120 Mierniki do badan instalacji elektrycznych / rezystancja przejscia Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na wzorcach impedancji 50 Hz 0,01 Ω CMC 0,60 % 50 Hz 0,1 Ω CMC 0,20 % 50 Hz 1 Ω CMC 0,011 % Revizni pristroje / Prechodovy odpor Kalibrace – elektricke veliciny Prime mereni na etalonech impedance 50 Hz 0,01 Ω CMC 0,60 % 50 Hz 0,1 Ω CMC 0,20 % 50 Hz 1 Ω CMC 0,011 % KP-PB-120","search_en":"Inspection equipment / Transient resistance Calibration – electrical quantities Direct measurement on impedance standards Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on impedance standards 50 Hz 50 Hz 50 Hz KP-PB-120","search_zh":"电气安装检测仪 / 过渡电阻 校准 – 电学量 在阻抗标准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在阻抗标准器上直接测量 50 Hz 50 Hz 50 Hz KP-PB-120","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":93,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"50 Hz","range":"0,01 Ω","cmc":"0,60 %"},{"name":"50 Hz","range":"0,1 Ω","cmc":"0,20 %"},{"name":"50 Hz","range":"1 Ω","cmc":"0,011 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Prüfgeräte für elektrische Installationen / Übergangswiderstand Kalibrierung – elektrische Größen Direkte Messung an Impedanznormalen Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung an Impedanznormalen 50 Hz 50 Hz 50 Hz KP-PB-120","technique_de":"Direkte Messung an Impedanznormalen","techniques_de":["Direkte Messung an Impedanznormalen"],"test_object_de":"Prüfgeräte für elektrische Installationen / Übergangswiderstand"},{"_id":"a311229954f0183725fbf28a","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"14","test_object":"Mierniki do badań instalacji elektrycznych / prąd upływu","test_object_en":"Inspection equipment / Leakage current","test_object_zh":"电气安装检测仪 / 泄漏电流","test_object_cs":"Revizní přístroje / Unikající proud","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"2 mA","cmc":"1,7 %"},{"name":"","range":"4,7 mA","cmc":"1,7 %"},{"name":"","range":"7,7 mA","cmc":"1,7 %"}],"parameters_en":[{"name":"","range":"2 mA","cmc":"1,7 %"},{"name":"","range":"4,7 mA","cmc":"1,7 %"},{"name":"","range":"7,7 mA","cmc":"1,7 %"}],"parameters_zh":[{"name":"","range":"2 mA","cmc":"1,7 %"},{"name":"","range":"4,7 mA","cmc":"1,7 %"},{"name":"","range":"7,7 mA","cmc":"1,7 %"}],"parameters_cs":[{"name":"","range":"2 mA","cmc":"1,7 %"},{"name":"","range":"4,7 mA","cmc":"1,7 %"},{"name":"","range":"7,7 mA","cmc":"1,7 %"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych lub pomiar bezpośredni multimetrem","technique_en":"Direct measurement on a calibrator of inspection instruments or direct measurement with a multimeter","technique_zh":"在电气安装检测仪校准器上直接测量或用万用表直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů nebo přímé měření multimetrem","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych lub pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement on a calibrator of inspection instruments or direct measurement with a multimeter"],"techniques_zh":["在电气安装检测仪校准器上直接测量或用万用表直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů nebo přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n2 mA CMC 1,7 %\n4,7 mA CMC 1,7 %\n7,7 mA CMC 1,7 %\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych lub pomiar bezpośredni multimetrem","reference":"KP-PB-120","norm_bases":["KP-PB-120"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / prąd upływu Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych lub pomiar bezpośredni multimetrem 2 mA CMC 1,7 % 4,7 mA CMC 1,7 % 7,7 mA CMC 1,7 % Revizní přístroje / Unikající proud Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů nebo přímé měření multimetrem 2 mA CMC 1,7 % 4,7 mA CMC 1,7 % 7,7 mA CMC 1,7 % KP-PB-120 Mierniki do badan instalacji elektrycznych / prad uplywu Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych lub pomiar bezposredni multimetrem 2 mA CMC 1,7 % 4,7 mA CMC 1,7 % 7,7 mA CMC 1,7 % Revizni pristroje / Unikajici proud Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju nebo prime mereni multimetrem 2 mA CMC 1,7 % 4,7 mA CMC 1,7 % 7,7 mA CMC 1,7 % KP-PB-120","search_en":"Inspection equipment / Leakage current Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments or direct measurement with a multimeter Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a calibrator of inspection instruments or direct measurement with a multimeter KP-PB-120","search_zh":"电气安装检测仪 / 泄漏电流 校准 – 电学量 在电气安装检测仪校准器上直接测量或用万用表直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在电气安装检测仪校准器上直接测量或用万用表直接测量 KP-PB-120","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":94,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Prüfgeräte für elektrische Installationen / Ableitstrom Kalibrierung – elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen oder direkte Messung mit einem Multimeter Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen oder direkte Messung mit einem Multimeter KP-PB-120","technique_de":"Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen oder direkte Messung mit einem Multimeter","techniques_de":["Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen oder direkte Messung mit einem Multimeter"],"test_object_de":"Prüfgeräte für elektrische Installationen / Ableitstrom"},{"_id":"a5538a28c6587ddb6b41fa70","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"14","test_object":"Mierniki do badań instalacji elektrycznych / prąd zadziałania wyłączników różnicowoprądowych","test_object_en":"Inspection equipment / Tripping current of residual current circuit breakers","test_object_zh":"电气安装检测仪 / 剩余电流保护器动作电流","test_object_cs":"Revizní přístroje / Vypínací proud proudových chráničů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 2 mA do 3000 mA","cmc":"1,4 %"}],"parameters_en":[{"name":"","range":"2 mA to 3000 mA","cmc":"1,4 %"}],"parameters_zh":[{"name":"","range":"2 mA 至 3000 mA","cmc":"1,4 %"}],"parameters_cs":[{"name":"","range":"2 mA až 3000 mA","cmc":"1,4 %"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","technique_en":"Direct measurement on a calibrator of inspection instruments","technique_zh":"在电气安装检测仪校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych"],"techniques_en":["Direct measurement on a calibrator of inspection instruments"],"techniques_zh":["在电气安装检测仪校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 2 mA do 3000 mA CMC 1,4 %\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","reference":"KP-PB-120","norm_bases":["KP-PB-120"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / prąd zadziałania wyłączników różnicowoprądowych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych od 2 mA do 3000 mA CMC 1,4 % Revizní přístroje / Vypínací proud proudových chráničů Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů 2 mA až 3000 mA CMC 1,4 % KP-PB-120 Mierniki do badan instalacji elektrycznych / prad zadzialania wylacznikow roznicowopradowych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych od 2 mA do 3000 mA CMC 1,4 % Revizni pristroje / Vypinaci proud proudovych chranicu Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju 2 mA az 3000 mA CMC 1,4 % KP-PB-120","search_en":"Inspection equipment / Tripping current of residual current circuit breakers Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a calibrator of inspection instruments KP-PB-120","search_zh":"电气安装检测仪 / 剩余电流保护器动作电流 校准 – 电学量 在电气安装检测仪校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在电气安装检测仪校准器上直接测量 KP-PB-120","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":95,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 2 mA bis 3000 mA","cmc":"1,4 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Prüfgeräte für elektrische Installationen / Auslösestrom von Fehlerstromschutzschaltern Kalibrierung – elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen KP-PB-120","technique_de":"Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen","techniques_de":["Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen"],"test_object_de":"Prüfgeräte für elektrische Installationen / Auslösestrom von Fehlerstromschutzschaltern"},{"_id":"187345628fe594dfe76da9b7","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"14","test_object":"Mierniki do badań instalacji elektrycznych / czas zadziałania wyłączników różnicowoprądowych","test_object_en":"Inspection equipment / Tripping time of residual current circuit breakers","test_object_zh":"电气安装检测仪 / 剩余电流保护器动作时间","test_object_cs":"Revizní přístroje / Vypínací čas proudových chráničů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 ms do 400 ms","cmc":"0,40 ms"}],"parameters_en":[{"name":"","range":"10 ms to 400 ms","cmc":"0,40 ms"}],"parameters_zh":[{"name":"","range":"10 ms 至 400 ms","cmc":"0,40 ms"}],"parameters_cs":[{"name":"","range":"10 ms až 400 ms","cmc":"0,40 ms"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","technique_en":"Direct measurement on a calibrator of inspection instruments","technique_zh":"在电气安装检测仪校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych"],"techniques_en":["Direct measurement on a calibrator of inspection instruments"],"techniques_zh":["在电气安装检测仪校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 10 ms do 400 ms CMC 0,40 ms\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","reference":"KP-PB-120","norm_bases":["KP-PB-120"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / czas zadziałania wyłączników różnicowoprądowych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych od 10 ms do 400 ms CMC 0,40 ms Revizní přístroje / Vypínací čas proudových chráničů Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů 10 ms až 400 ms CMC 0,40 ms KP-PB-120 Mierniki do badan instalacji elektrycznych / czas zadzialania wylacznikow roznicowopradowych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych od 10 ms do 400 ms CMC 0,40 ms Revizni pristroje / Vypinaci cas proudovych chranicu Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju 10 ms az 400 ms CMC 0,40 ms KP-PB-120","search_en":"Inspection equipment / Tripping time of residual current circuit breakers Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on a calibrator of inspection instruments KP-PB-120","search_zh":"电气安装检测仪 / 剩余电流保护器动作时间 校准 – 电学量 在电气安装检测仪校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在电气安装检测仪校准器上直接测量 KP-PB-120","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":96,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 10 ms bis 400 ms","cmc":"0,40 ms"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Prüfgeräte für elektrische Installationen / Auslösezeit von Fehlerstromschutzschaltern Kalibrierung – elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen KP-PB-120","technique_de":"Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen","techniques_de":["Direkte Messung am Kalibrator für Prüfgeräte elektrischer Installationen"],"test_object_de":"Prüfgeräte für elektrische Installationen / Auslösezeit von Fehlerstromschutzschaltern"},{"_id":"e3d359532c1f738b9e749606","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"16","test_object":"Oscyloskop / wzmacniacz odchylania pionowego","test_object_en":"Oscilloscope / Vertical amplifier","test_object_zh":"示波器 / 垂直放大器","test_object_cs":"Osciloskop / Vertikální zesilovač","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0 Hz","range":"od 2 mV do 50 V","cmc":"0,012 % + 20 µV"},{"name":"1 kHz","range":"od 2 mV do 50 V","cmc":"0,13 % + 40 µV"}],"parameters_en":[{"name":"0 Hz","range":"2 mV to 50 V","cmc":"0,012 % + 20 µV"},{"name":"1 kHz","range":"2 mV to 50 V","cmc":"0,13 % + 40 µV"}],"parameters_zh":[{"name":"0 Hz","range":"2 mV 至 50 V","cmc":"0,012 % + 20 µV"},{"name":"1 kHz","range":"2 mV 至 50 V","cmc":"0,13 % + 40 µV"}],"parameters_cs":[{"name":"0 Hz","range":"2 mV až 50 V","cmc":"0,012 % + 20 µV"},{"name":"1 kHz","range":"2 mV až 50 V","cmc":"0,13 % + 40 µV"}],"technique":"Pomiar bezpośredni na kalibratorze oscyloskopów","technique_en":"Direct measurement on an oscilloscope calibrator","technique_zh":"在示波器校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru osciloskopů","techniques":["Pomiar bezpośredni na kalibratorze oscyloskopów"],"techniques_en":["Direct measurement on an oscilloscope calibrator"],"techniques_zh":["在示波器校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru osciloskopů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 Hz od 2 mV do 50 V CMC 0,012 % + 20 µV\n1 kHz od 2 mV do 50 V CMC 0,13 % + 40 µV\nPomiar bezpośredni na kalibratorze oscyloskopów","reference":"KP-PB-121","norm_bases":["KP-PB-121"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Oscyloskop / wzmacniacz odchylania pionowego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze oscyloskopów 0 Hz od 2 mV do 50 V CMC 0,012 % + 20 µV 1 kHz od 2 mV do 50 V CMC 0,13 % + 40 µV Osciloskop / Vertikální zesilovač Kalibrace – elektrické veličiny Přímé měření na kalibrátoru osciloskopů 0 Hz 2 mV až 50 V CMC 0,012 % + 20 µV 1 kHz 2 mV až 50 V CMC 0,13 % + 40 µV KP-PB-121 Oscyloskop / wzmacniacz odchylania pionowego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze oscyloskopow 0 Hz od 2 mV do 50 V CMC 0,012 % + 20 µV 1 kHz od 2 mV do 50 V CMC 0,13 % + 40 µV Osciloskop / Vertikalni zesilovac Kalibrace – elektricke veliciny Prime mereni na kalibratoru osciloskopu 0 Hz 2 mV az 50 V CMC 0,012 % + 20 µV 1 kHz 2 mV az 50 V CMC 0,13 % + 40 µV KP-PB-121","search_en":"Oscilloscope / Vertical amplifier Calibration – electrical quantities Direct measurement on an oscilloscope calibrator Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on an oscilloscope calibrator 0 Hz 1 kHz KP-PB-121","search_zh":"示波器 / 垂直放大器 校准 – 电学量 在示波器校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在示波器校准器上直接测量 0 Hz 1 kHz KP-PB-121","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":97,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"0 Hz","range":"von 2 mV bis 50 V","cmc":"0,012 % + 20 µV"},{"name":"1 kHz","range":"von 2 mV bis 50 V","cmc":"0,13 % + 40 µV"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Oszilloskop / Vertikalverstärker Kalibrierung – elektrische Größen Direkte Messung am Oszilloskopkalibrator Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Oszilloskopkalibrator 0 Hz 1 kHz KP-PB-121","technique_de":"Direkte Messung am Oszilloskopkalibrator","techniques_de":["Direkte Messung am Oszilloskopkalibrator"],"test_object_de":"Oszilloskop / Vertikalverstärker"},{"_id":"7f9f0d8fe0ca295f10e03b03","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"16","test_object":"Oscyloskop / podstawa czasu","test_object_en":"Oscilloscope / Time base","test_object_zh":"示波器 / 时基","test_object_cs":"Osciloskop / Časová základna","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 2 ns do 5 s","cmc":"0,010 %"}],"parameters_en":[{"name":"","range":"2 ns to 5 s","cmc":"0,010 %"}],"parameters_zh":[{"name":"","range":"2 ns 至 5 s","cmc":"0,010 %"}],"parameters_cs":[{"name":"","range":"2 ns až 5 s","cmc":"0,010 %"}],"technique":"Pomiar bezpośredni na kalibratorze oscyloskopów","technique_en":"Direct measurement on an oscilloscope calibrator","technique_zh":"在示波器校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru osciloskopů","techniques":["Pomiar bezpośredni na kalibratorze oscyloskopów"],"techniques_en":["Direct measurement on an oscilloscope calibrator"],"techniques_zh":["在示波器校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru osciloskopů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 2 ns do 5 s CMC 0,010 %\nPomiar bezpośredni na kalibratorze oscyloskopów","reference":"KP-PB-121","norm_bases":["KP-PB-121"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Oscyloskop / podstawa czasu Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze oscyloskopów od 2 ns do 5 s CMC 0,010 % Osciloskop / Časová základna Kalibrace – elektrické veličiny Přímé měření na kalibrátoru osciloskopů 2 ns až 5 s CMC 0,010 % KP-PB-121 Oscyloskop / podstawa czasu Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze oscyloskopow od 2 ns do 5 s CMC 0,010 % Osciloskop / Casova zakladna Kalibrace – elektricke veliciny Prime mereni na kalibratoru osciloskopu 2 ns az 5 s CMC 0,010 % KP-PB-121","search_en":"Oscilloscope / Time base Calibration – electrical quantities Direct measurement on an oscilloscope calibrator Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on an oscilloscope calibrator KP-PB-121","search_zh":"示波器 / 时基 校准 – 电学量 在示波器校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在示波器校准器上直接测量 KP-PB-121","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":98,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"","range":"von 2 ns bis 5 s","cmc":"0,010 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Oszilloskop / Zeitbasis Kalibrierung – elektrische Größen Direkte Messung am Oszilloskopkalibrator Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Oszilloskopkalibrator KP-PB-121","technique_de":"Direkte Messung am Oszilloskopkalibrator","techniques_de":["Direkte Messung am Oszilloskopkalibrator"],"test_object_de":"Oszilloskop / Zeitbasis"},{"_id":"234e0ded707558a1cc36703c","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"16","test_object":"Oscyloskop / częstotliwość graniczna","test_object_en":"Oscilloscope / Limit frequency","test_object_zh":"示波器 / 截止频率","test_object_cs":"Osciloskop / Mezní frekvence","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Ω, 600 mVp-p (międzyszczytowo)","range":"od 5 MHz do 600 MHz","cmc":"15 %"}],"parameters_en":[{"name":"50 Ω 600 mVp-p","range":"5 MHz to 600 MHz","cmc":"15 %"}],"parameters_zh":[{"name":"50 Ω，600 mV峰峰值","range":"5 MHz 至 600 MHz","cmc":"15 %"}],"parameters_cs":[{"name":"50 Ω, 600 mVš-š","range":"5 MHz až 600 MHz","cmc":"15 %"}],"technique":"Pomiar bezpośredni na kalibratorze oscyloskopów","technique_en":"Direct measurement on an oscilloscope calibrator","technique_zh":"在示波器校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru osciloskopů","techniques":["Pomiar bezpośredni na kalibratorze oscyloskopów"],"techniques_en":["Direct measurement on an oscilloscope calibrator"],"techniques_zh":["在示波器校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru osciloskopů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Ω, 600 mVp-p (międzyszczytowo) od 5 MHz do 600 MHz CMC 15 %\nPomiar bezpośredni na kalibratorze oscyloskopów","reference":"KP-PB-121","norm_bases":["KP-PB-121"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Oscyloskop / częstotliwość graniczna Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze oscyloskopów 50 Ω, 600 mVp-p (międzyszczytowo) od 5 MHz do 600 MHz CMC 15 % Osciloskop / Mezní frekvence Kalibrace – elektrické veličiny Přímé měření na kalibrátoru osciloskopů 50 Ω, 600 mVš-š 5 MHz až 600 MHz CMC 15 % KP-PB-121 Oscyloskop / czestotliwosc graniczna Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze oscyloskopow 50 Ω, 600 mVp-p (miedzyszczytowo) od 5 MHz do 600 MHz CMC 15 % Osciloskop / Mezni frekvence Kalibrace – elektricke veliciny Prime mereni na kalibratoru osciloskopu 50 Ω, 600 mVs-s 5 MHz az 600 MHz CMC 15 % KP-PB-121","search_en":"Oscilloscope / Limit frequency Calibration – electrical quantities Direct measurement on an oscilloscope calibrator Uherský Brod II CMC for the field of measured quantity: Electrical quantities Direct measurement on an oscilloscope calibrator 50 Ω 600 mVp-p KP-PB-121","search_zh":"示波器 / 截止频率 校准 – 电学量 在示波器校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：电学量 在示波器校准器上直接测量 50 Ω，600 mV峰峰值 KP-PB-121","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":99,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – elektrische Größen","parameters_de":[{"name":"50 Ω, 600 mVp-p (Spitze-Spitze)","range":"von 5 MHz bis 600 MHz","cmc":"15 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: elektrische Größen","search_de":"Oszilloskop / Grenzfrequenz Kalibrierung – elektrische Größen Direkte Messung am Oszilloskopkalibrator Uherský Brod II CMC für den Messgrößenbereich: elektrische Größen Direkte Messung am Oszilloskopkalibrator 50 Ω, 600 mVp-p (Spitze-Spitze) KP-PB-121","technique_de":"Direkte Messung am Oszilloskopkalibrator","techniques_de":["Direkte Messung am Oszilloskopkalibrator"],"test_object_de":"Oszilloskop / Grenzfrequenz"},{"_id":"ba4632aee3a552b6a9ffc680","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / generatory częstotliwości","test_object_en":"Frequency / Frequency generators","test_object_zh":"频率 / 频率发生器","test_object_cs":"Frekvence / Generátory frekvence","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 0,001 Hz do 20 GHz","cmc":"9,3·10⁻⁸"}],"parameters_en":[{"name":"","range":"0,001 Hz to 20 GHz","cmc":"9,3·10⁻⁸"}],"parameters_zh":[{"name":"","range":"0,001 Hz 至 20 GHz","cmc":"9,3·10⁻⁸"}],"parameters_cs":[{"name":"","range":"0,001 Hz až 20 GHz","cmc":"9,3·10⁻⁸"}],"technique":"Pomiar bezpośredni częstościomierzem wzorcowym","technique_en":"Direct measurement by a reference counter","technique_zh":"用标准计数器直接测量","technique_cs":"Přímé měření etalonovým čítačem","techniques":["Pomiar bezpośredni częstościomierzem wzorcowym"],"techniques_en":["Direct measurement by a reference counter"],"techniques_zh":["用标准计数器直接测量"],"techniques_cs":["Přímé měření etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 0,001 Hz do 20 GHz CMC 9,3·10⁻⁸\nPomiar bezpośredni częstościomierzem wzorcowym","reference":"KP-PB-100","norm_bases":["KP-PB-100"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / generatory częstotliwości Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni częstościomierzem wzorcowym od 0,001 Hz do 20 GHz CMC 9,3·10⁻⁸ Frekvence / Generátory frekvence Kalibrace – veličiny času a frekvence Přímé měření etalonovým čítačem 0,001 Hz až 20 GHz CMC 9,3·10⁻⁸ KP-PB-100 Czestotliwosc / generatory czestotliwosci Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni czestosciomierzem wzorcowym od 0,001 Hz do 20 GHz CMC 9,3·10⁻⁸ Frekvence / Generatory frekvence Kalibrace – veliciny casu a frekvence Prime mereni etalonovym citacem 0,001 Hz az 20 GHz CMC 9,3·10⁻⁸ KP-PB-100","search_en":"Frequency / Frequency generators Calibration – time and frequency quantities Direct measurement by a reference counter Uherský Brod II CMC for the field of measured quantity: Time and frequency quantities Direct measurement by a reference counter KP-PB-100","search_zh":"频率 / 频率发生器 校准 – 时间和频率量 用标准计数器直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：时间和频率量 用标准计数器直接测量 KP-PB-100","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":100,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Zeit und Frequenz","parameters_de":[{"name":"","range":"von 0,001 Hz bis 20 GHz","cmc":"9,3·10⁻⁸"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Zeit und Frequenz","search_de":"Frequenz / Frequenzgeneratoren Kalibrierung – Zeit und Frequenz Direkte Messung mit einem Referenzfrequenzzähler Uherský Brod II CMC für den Messgrößenbereich: Zeit und Frequenz Direkte Messung mit einem Referenzfrequenzzähler KP-PB-100","technique_de":"Direkte Messung mit einem Referenzfrequenzzähler","techniques_de":["Direkte Messung mit einem Referenzfrequenzzähler"],"test_object_de":"Frequenz / Frequenzgeneratoren"},{"_id":"4876635b496d104d3f956b06","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / mierniki częstotliwości","test_object_en":"Frequency / frequency meters","test_object_zh":"频率 / 频率测量仪器","test_object_cs":"Frekvence / měřidla frekvence","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"sygnał sinusoidalny","range":"od 1 Hz do 10 MHz","cmc":"20·10⁻⁶"}],"parameters_en":[{"name":"sine wave signal","range":"1 Hz to 10 MHz","cmc":"20·10⁻⁶"}],"parameters_zh":[{"name":"正弦信号","range":"1 Hz 至 10 MHz","cmc":"20·10⁻⁶"}],"parameters_cs":[{"name":"sinusový signál","range":"1 Hz až 10 MHz","cmc":"20·10⁻⁶"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym","technique_en":"Direct measurement on a reference calibrator","technique_zh":"在标准校准器上直接测量","technique_cs":"Přímé měření na etalonovém kalibrátoru","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym"],"techniques_en":["Direct measurement on a reference calibrator"],"techniques_zh":["在标准校准器上直接测量"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nsygnał sinusoidalny od 1 Hz do 10 MHz CMC 20·10⁻⁶\nPomiar bezpośredni na kalibratorze wzorcowym","reference":"KP-PB-100","norm_bases":["KP-PB-100"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / mierniki częstotliwości Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni na kalibratorze wzorcowym sygnał sinusoidalny od 1 Hz do 10 MHz CMC 20·10⁻⁶ Frekvence / měřidla frekvence Kalibrace – veličiny času a frekvence Přímé měření na etalonovém kalibrátoru sinusový signál 1 Hz až 10 MHz CMC 20·10⁻⁶ KP-PB-100 Czestotliwosc / mierniki czestotliwosci Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni na kalibratorze wzorcowym sygnal sinusoidalny od 1 Hz do 10 MHz CMC 20·10⁻⁶ Frekvence / meridla frekvence Kalibrace – veliciny casu a frekvence Prime mereni na etalonovem kalibratoru sinusovy signal 1 Hz az 10 MHz CMC 20·10⁻⁶ KP-PB-100","search_en":"Frequency / frequency meters Calibration – time and frequency quantities Direct measurement on a reference calibrator Uherský Brod II CMC for the field of measured quantity: Time and frequency quantities Direct measurement on a reference calibrator sine wave signal KP-PB-100","search_zh":"频率 / 频率测量仪器 校准 – 时间和频率量 在标准校准器上直接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：时间和频率量 在标准校准器上直接测量 正弦信号 KP-PB-100","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":101,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Zeit und Frequenz","parameters_de":[{"name":"Sinussignal","range":"von 1 Hz bis 10 MHz","cmc":"20·10⁻⁶"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Zeit und Frequenz","search_de":"Frequenz / Frequenzmesser Kalibrierung – Zeit und Frequenz Direkte Messung am Referenzkalibrator Uherský Brod II CMC für den Messgrößenbereich: Zeit und Frequenz Direkte Messung am Referenzkalibrator Sinussignal KP-PB-100","technique_de":"Direkte Messung am Referenzkalibrator","techniques_de":["Direkte Messung am Referenzkalibrator"],"test_object_de":"Frequenz / Frequenzmesser"},{"_id":"9607b0ae2b93e846f875a47a","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"2","test_object":"Przedział czasu / ręcznie wyzwalane mierniki przedziałów czasu","test_object_en":"Time interval / Manually operated time meters","test_object_zh":"时间间隔 / 手动启停时间间隔测量仪","test_object_cs":"Časový interval / Ručně spínané měřiče časového intervalu","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 0:00:00 h:min:s do 23:59:59 h:min:s","cmc":"0,10 s"}],"parameters_en":[{"name":"","range":"0:00:00 h:min:s to 23:59:59 h:min:s","cmc":"0,10 s"}],"parameters_zh":[{"name":"","range":"0:00:00 h:min:s 至 23:59:59 h:min:s","cmc":"0,10 s"}],"parameters_cs":[{"name":"","range":"0:00:00 h:min:s až 23:59:59 h:min:s","cmc":"0,10 s"}],"technique":"Porównanie z wzorcem przedziału czasu","technique_en":"Comparison with a time interval standard","technique_zh":"与时间间隔标准器比较","technique_cs":"Porovnání s etalonem časového intervalu","techniques":["Porównanie z wzorcem przedziału czasu"],"techniques_en":["Comparison with a time interval standard"],"techniques_zh":["与时间间隔标准器比较"],"techniques_cs":["Porovnání s etalonem časového intervalu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 0:00:00 h:min:s do 23:59:59 h:min:s CMC 0,10 s\nPorównanie z wzorcem przedziału czasu","reference":"KP-PB-100","norm_bases":["KP-PB-100"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / ręcznie wyzwalane mierniki przedziałów czasu Wzorcowanie – wielkości czasu i częstotliwości Porównanie z wzorcem przedziału czasu od 0:00:00 h:min:s do 23:59:59 h:min:s CMC 0,10 s Časový interval / Ručně spínané měřiče časového intervalu Kalibrace – veličiny času a frekvence Porovnání s etalonem časového intervalu 0:00:00 h:min:s až 23:59:59 h:min:s CMC 0,10 s KP-PB-100 Przedzial czasu / recznie wyzwalane mierniki przedzialow czasu Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie z wzorcem przedzialu czasu od 0:00:00 h:min:s do 23:59:59 h:min:s CMC 0,10 s Casovy interval / Rucne spinane merice casoveho intervalu Kalibrace – veliciny casu a frekvence Porovnani s etalonem casoveho intervalu 0:00:00 h:min:s az 23:59:59 h:min:s CMC 0,10 s KP-PB-100","search_en":"Time interval / Manually operated time meters Calibration – time and frequency quantities Comparison with a time interval standard Uherský Brod II CMC for the field of measured quantity: Time and frequency quantities Comparison with a time interval standard KP-PB-100","search_zh":"时间间隔 / 手动启停时间间隔测量仪 校准 – 时间和频率量 与时间间隔标准器比较 乌赫尔斯基布罗德 II 被测量领域的CMC：时间和频率量 与时间间隔标准器比较 KP-PB-100","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":102,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Zeit und Frequenz","parameters_de":[{"name":"","range":"von 0:00:00 h:min:s bis 23:59:59 h:min:s","cmc":"0,10 s"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Zeit und Frequenz","search_de":"Zeitintervall / manuell ausgelöste Zeitintervallmessgeräte Kalibrierung – Zeit und Frequenz Vergleich mit einem Zeitintervallnormal Uherský Brod II CMC für den Messgrößenbereich: Zeit und Frequenz Vergleich mit einem Zeitintervallnormal KP-PB-100","technique_de":"Vergleich mit einem Zeitintervallnormal","techniques_de":["Vergleich mit einem Zeitintervallnormal"],"test_object_de":"Zeitintervall / manuell ausgelöste Zeitintervallmessgeräte"},{"_id":"9b5807ca401e0f102bcf29cb","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"3","test_object":"Podstawa czasu stoperów cyfrowych","test_object_en":"Time base of digital stopwatch","test_object_zh":"数字秒表时基","test_object_cs":"Časová základna digitálních stopek","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 10 Hz do 10 MHz","cmc":"4,7·10⁻⁶"}],"parameters_en":[{"name":"","range":"from 10 Hz to 10 MHz","cmc":"4,7·10⁻⁶"}],"parameters_zh":[{"name":"","range":"10 Hz 至 10 MHz","cmc":"4,7·10⁻⁶"}],"parameters_cs":[{"name":"","range":"10 Hz až 10 MHz","cmc":"4,7·10⁻⁶"}],"technique":"Pomiar pośredni częstościomierzem wzorcowym","technique_en":"Indirect measurement by a reference counter","technique_zh":"用标准计数器间接测量","technique_cs":"Nepřímé měření etalonovým čítačem","techniques":["Pomiar pośredni częstościomierzem wzorcowym"],"techniques_en":["Indirect measurement by a reference counter"],"techniques_zh":["用标准计数器间接测量"],"techniques_cs":["Nepřímé měření etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 10 Hz do 10 MHz CMC 4,7·10⁻⁶\nPomiar pośredni częstościomierzem wzorcowym","reference":"KP-PB-100","norm_bases":["KP-PB-100"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Podstawa czasu stoperów cyfrowych Wzorcowanie – wielkości czasu i częstotliwości Pomiar pośredni częstościomierzem wzorcowym od 10 Hz do 10 MHz CMC 4,7·10⁻⁶ Časová základna digitálních stopek Kalibrace – veličiny času a frekvence Nepřímé měření etalonovým čítačem 10 Hz až 10 MHz CMC 4,7·10⁻⁶ KP-PB-100 Podstawa czasu stoperow cyfrowych Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar posredni czestosciomierzem wzorcowym od 10 Hz do 10 MHz CMC 4,7·10⁻⁶ Casova zakladna digitalnich stopek Kalibrace – veliciny casu a frekvence Neprime mereni etalonovym citacem 10 Hz az 10 MHz CMC 4,7·10⁻⁶ KP-PB-100","search_en":"Time base of digital stopwatch Calibration – time and frequency quantities Indirect measurement by a reference counter Uherský Brod II CMC for the field of measured quantity: Time and frequency quantities Indirect measurement by a reference counter KP-PB-100","search_zh":"数字秒表时基 校准 – 时间和频率量 用标准计数器间接测量 乌赫尔斯基布罗德 II 被测量领域的CMC：时间和频率量 用标准计数器间接测量 KP-PB-100","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":103,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – Zeit und Frequenz","parameters_de":[{"name":"","range":"von 10 Hz bis 10 MHz","cmc":"4,7·10⁻⁶"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Zeit und Frequenz","search_de":"Zeitbasis digitaler Stoppuhren Kalibrierung – Zeit und Frequenz Indirekte Messung mit einem Referenzfrequenzzähler Uherský Brod II CMC für den Messgrößenbereich: Zeit und Frequenz Indirekte Messung mit einem Referenzfrequenzzähler KP-PB-100","technique_de":"Indirekte Messung mit einem Referenzfrequenzzähler","techniques_de":["Indirekte Messung mit einem Referenzfrequenzzähler"],"test_object_de":"Zeitbasis digitaler Stoppuhren"},{"_id":"084356786102dd4b5de7f064","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność względna","test_object_en":"Relative humidity","test_object_zh":"相对湿度","test_object_cs":"Relativní vlhkost","methodology":"Wzorcowanie – wielkości fizykochemiczne","methodology_en":"Calibration – physicochemical quantities","methodology_zh":"校准 – 物理化学量","methodology_cs":"Kalibrace – fyzikálně chemické veličiny","parameters":[{"name":"(10 do 60) °C","range":"od 10 % RH do 40 % RH","cmc":"0,9 % RH"},{"name":"(10 do 60) °C","range":"od 40 % RH do 70 % RH","cmc":"1,0 % RH"},{"name":"(10 do 60) °C","range":"od 70 % RH do 80 % RH","cmc":"1,1 % RH"},{"name":"(10 do 60) °C","range":"od 80 % RH do 90 % RH","cmc":"1,2 % RH"},{"name":"(10 do 60) °C","range":"od 90 % RH do 95 % RH","cmc":"1,6 % RH"}],"parameters_en":[{"name":"(10 to 60) °C","range":"10 % RH to 40 % RH","cmc":"0,9 % RH"},{"name":"(10 to 60) °C","range":"40 % RH to 70 % RH","cmc":"1,0 % RH"},{"name":"(10 to 60) °C","range":"70 % RH to 80 % RH","cmc":"1,1 % RH"},{"name":"(10 to 60) °C","range":"80 % RH to 90 % RH","cmc":"1,2 % RH"},{"name":"(10 to 60) °C","range":"90 % RH to 95 % RH","cmc":"1,6 % RH"}],"parameters_zh":[{"name":"(10 至 60) °C","range":"10 % RH 至 40 % RH","cmc":"0,9 % RH"},{"name":"(10 至 60) °C","range":"40 % RH 至 70 % RH","cmc":"1,0 % RH"},{"name":"(10 至 60) °C","range":"70 % RH 至 80 % RH","cmc":"1,1 % RH"},{"name":"(10 至 60) °C","range":"80 % RH 至 90 % RH","cmc":"1,2 % RH"},{"name":"(10 至 60) °C","range":"90 % RH 至 95 % RH","cmc":"1,6 % RH"}],"parameters_cs":[{"name":"(10 až 60) °C","range":"10 % RH až 40 % RH","cmc":"0,9 % RH"},{"name":"(10 až 60) °C","range":"40 % RH až 70 % RH","cmc":"1,0 % RH"},{"name":"(10 až 60) °C","range":"70 % RH až 80 % RH","cmc":"1,1 % RH"},{"name":"(10 až 60) °C","range":"80 % RH až 90 % RH","cmc":"1,2 % RH"},{"name":"(10 až 60) °C","range":"90 % RH až 95 % RH","cmc":"1,6 % RH"}],"technique":"Porównanie z wzorcem wilgotności","technique_en":"Comparison with a humidity standard","technique_zh":"与湿度标准器比较","technique_cs":"Porovnání s etalonem vlhkosti","techniques":["Porównanie z wzorcem wilgotności"],"techniques_en":["Comparison with a humidity standard"],"techniques_zh":["与湿度标准器比较"],"techniques_cs":["Porovnání s etalonem vlhkosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne\nZakres:\n(10 do 60) °C od 10 % RH do 40 % RH CMC 0,9 % RH\n(10 do 60) °C od 40 % RH do 70 % RH CMC 1,0 % RH\n(10 do 60) °C od 70 % RH do 80 % RH CMC 1,1 % RH\n(10 do 60) °C od 80 % RH do 90 % RH CMC 1,2 % RH\n(10 do 60) °C od 90 % RH do 95 % RH CMC 1,6 % RH\nPorównanie z wzorcem wilgotności","reference":"KP-PB-99","norm_bases":["KP-PB-99"],"lab_section":"Mladá Boleslav","lab_section_en":"Mladá Boleslav","lab_section_zh":"姆拉达-博莱斯拉夫","lab_section_cs":"Mladá Boleslav","lab_address":"Komenského náměstí 90/10, 293 01 Mladá Boleslav","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities","regulatory_area_zh":"被测量领域的CMC：物理化学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność względna Wzorcowanie – wielkości fizykochemiczne Porównanie z wzorcem wilgotności (10 do 60) °C od 10 % RH do 40 % RH CMC 0,9 % RH (10 do 60) °C od 40 % RH do 70 % RH CMC 1,0 % RH (10 do 60) °C od 70 % RH do 80 % RH CMC 1,1 % RH (10 do 60) °C od 80 % RH do 90 % RH CMC 1,2 % RH (10 do 60) °C od 90 % RH do 95 % RH CMC 1,6 % RH Relativní vlhkost Kalibrace – fyzikálně chemické veličiny Porovnání s etalonem vlhkosti (10 až 60) °C 10 % RH až 40 % RH CMC 0,9 % RH (10 až 60) °C 40 % RH až 70 % RH CMC 1,0 % RH (10 až 60) °C 70 % RH až 80 % RH CMC 1,1 % RH (10 až 60) °C 80 % RH až 90 % RH CMC 1,2 % RH (10 až 60) °C 90 % RH až 95 % RH CMC 1,6 % RH KP-PB-99 Wilgotnosc wzgledna Wzorcowanie – wielkosci fizykochemiczne Porownanie z wzorcem wilgotnosci (10 do 60) °C od 10 % RH do 40 % RH CMC 0,9 % RH (10 do 60) °C od 40 % RH do 70 % RH CMC 1,0 % RH (10 do 60) °C od 70 % RH do 80 % RH CMC 1,1 % RH (10 do 60) °C od 80 % RH do 90 % RH CMC 1,2 % RH (10 do 60) °C od 90 % RH do 95 % RH CMC 1,6 % RH Relativni vlhkost Kalibrace – fyzikalne chemicke veliciny Porovnani s etalonem vlhkosti (10 az 60) °C 10 % RH az 40 % RH CMC 0,9 % RH (10 az 60) °C 40 % RH az 70 % RH CMC 1,0 % RH (10 az 60) °C 70 % RH az 80 % RH CMC 1,1 % RH (10 az 60) °C 80 % RH az 90 % RH CMC 1,2 % RH (10 az 60) °C 90 % RH az 95 % RH CMC 1,6 % RH KP-PB-99","search_en":"Relative humidity Calibration – physicochemical quantities Comparison with a humidity standard Mladá Boleslav CMC for the field of measured quantity: Physicochemical quantities Comparison with a humidity standard (10 to 60) °C (10 to 60) °C (10 to 60) °C (10 to 60) °C (10 to 60) °C KP-PB-99","search_zh":"相对湿度 校准 – 物理化学量 与湿度标准器比较 姆拉达-博莱斯拉夫 被测量领域的CMC：物理化学量 与湿度标准器比较 (10 至 60) °C (10 至 60) °C (10 至 60) °C (10 至 60) °C (10 至 60) °C KP-PB-99","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":104,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Mladá Boleslav","methodology_de":"Kalibrierung – physikalisch-chemische Größen","parameters_de":[{"name":"(10 bis 60) °C","range":"von 10 % RH bis 40 % RH","cmc":"0,9 % RH"},{"name":"(10 bis 60) °C","range":"von 40 % RH bis 70 % RH","cmc":"1,0 % RH"},{"name":"(10 bis 60) °C","range":"von 70 % RH bis 80 % RH","cmc":"1,1 % RH"},{"name":"(10 bis 60) °C","range":"von 80 % RH bis 90 % RH","cmc":"1,2 % RH"},{"name":"(10 bis 60) °C","range":"von 90 % RH bis 95 % RH","cmc":"1,6 % RH"}],"regulatory_area_de":"CMC für den Messgrößenbereich: physikalisch-chemische Größen","search_de":"Relative Feuchte Kalibrierung – physikalisch-chemische Größen Vergleich mit einem Feuchtenormal Mladá Boleslav CMC für den Messgrößenbereich: physikalisch-chemische Größen Vergleich mit einem Feuchtenormal (10 bis 60) °C (10 bis 60) °C (10 bis 60) °C (10 bis 60) °C (10 bis 60) °C KP-PB-99","technique_de":"Vergleich mit einem Feuchtenormal","techniques_de":["Vergleich mit einem Feuchtenormal"],"test_object_de":"Relative Feuchte"},{"_id":"599d8e243a8221afd458cabd","lab_id":"6aedc19c98de217e6a2daa46","country":"CZ","accr_number":"2318","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność względna","test_object_en":"Relative humidity","test_object_zh":"相对湿度","test_object_cs":"Relativní vlhkost","methodology":"Wzorcowanie – wielkości fizykochemiczne","methodology_en":"Calibration – physicochemical quantities","methodology_zh":"校准 – 物理化学量","methodology_cs":"Kalibrace – fyzikálně chemické veličiny","parameters":[{"name":"(10 do 60) °C","range":"od 10 % RH do 40 % RH","cmc":"0,9 % RH"},{"name":"(10 do 60) °C","range":"od 40 % RH do 70 % RH","cmc":"1,0 % RH"},{"name":"(10 do 60) °C","range":"od 70 % RH do 80 % RH","cmc":"1,1 % RH"},{"name":"(10 do 60) °C","range":"od 80 % RH do 90 % RH","cmc":"1,2 % RH"},{"name":"(10 do 60) °C","range":"od 90 % RH do 95 % RH","cmc":"1,6 % RH"}],"parameters_en":[{"name":"(10 to 60) °C","range":"10 % RH to 40 % RH","cmc":"0,9 % RH"},{"name":"(10 to 60) °C","range":"40 % RH to 70 % RH","cmc":"1,0 % RH"},{"name":"(10 to 60) °C","range":"70 % RH to 80 % RH","cmc":"1,1 % RH"},{"name":"(10 to 60) °C","range":"80 % RH to 90 % RH","cmc":"1,2 % RH"},{"name":"(10 to 60) °C","range":"90 % RH to 95 % RH","cmc":"1,6 % RH"}],"parameters_zh":[{"name":"(10 至 60) °C","range":"10 % RH 至 40 % RH","cmc":"0,9 % RH"},{"name":"(10 至 60) °C","range":"40 % RH 至 70 % RH","cmc":"1,0 % RH"},{"name":"(10 至 60) °C","range":"70 % RH 至 80 % RH","cmc":"1,1 % RH"},{"name":"(10 至 60) °C","range":"80 % RH 至 90 % RH","cmc":"1,2 % RH"},{"name":"(10 至 60) °C","range":"90 % RH 至 95 % RH","cmc":"1,6 % RH"}],"parameters_cs":[{"name":"(10 až 60) °C","range":"10 % RH až 40 % RH","cmc":"0,9 % RH"},{"name":"(10 až 60) °C","range":"40 % RH až 70 % RH","cmc":"1,0 % RH"},{"name":"(10 až 60) °C","range":"70 % RH až 80 % RH","cmc":"1,1 % RH"},{"name":"(10 až 60) °C","range":"80 % RH až 90 % RH","cmc":"1,2 % RH"},{"name":"(10 až 60) °C","range":"90 % RH až 95 % RH","cmc":"1,6 % RH"}],"technique":"Porównanie z wzorcem wilgotności","technique_en":"Comparison with a humidity standard","technique_zh":"与湿度标准器比较","technique_cs":"Porovnání s etalonem vlhkosti","techniques":["Porównanie z wzorcem wilgotności"],"techniques_en":["Comparison with a humidity standard"],"techniques_zh":["与湿度标准器比较"],"techniques_cs":["Porovnání s etalonem vlhkosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne\nZakres:\n(10 do 60) °C od 10 % RH do 40 % RH CMC 0,9 % RH\n(10 do 60) °C od 40 % RH do 70 % RH CMC 1,0 % RH\n(10 do 60) °C od 70 % RH do 80 % RH CMC 1,1 % RH\n(10 do 60) °C od 80 % RH do 90 % RH CMC 1,2 % RH\n(10 do 60) °C od 90 % RH do 95 % RH CMC 1,6 % RH\nPorównanie z wzorcem wilgotności","reference":"KP-PB-99","norm_bases":["KP-PB-99"],"lab_section":"Uherský Brod II","lab_section_en":"Uherský Brod II","lab_section_zh":"乌赫尔斯基布罗德 II","lab_section_cs":"Uherský Brod II","lab_address":"Antonína Dvořáka 1274, 688 01 Uherský Brod","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities","regulatory_area_zh":"被测量领域的CMC：物理化学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność względna Wzorcowanie – wielkości fizykochemiczne Porównanie z wzorcem wilgotności (10 do 60) °C od 10 % RH do 40 % RH CMC 0,9 % RH (10 do 60) °C od 40 % RH do 70 % RH CMC 1,0 % RH (10 do 60) °C od 70 % RH do 80 % RH CMC 1,1 % RH (10 do 60) °C od 80 % RH do 90 % RH CMC 1,2 % RH (10 do 60) °C od 90 % RH do 95 % RH CMC 1,6 % RH Relativní vlhkost Kalibrace – fyzikálně chemické veličiny Porovnání s etalonem vlhkosti (10 až 60) °C 10 % RH až 40 % RH CMC 0,9 % RH (10 až 60) °C 40 % RH až 70 % RH CMC 1,0 % RH (10 až 60) °C 70 % RH až 80 % RH CMC 1,1 % RH (10 až 60) °C 80 % RH až 90 % RH CMC 1,2 % RH (10 až 60) °C 90 % RH až 95 % RH CMC 1,6 % RH KP-PB-99 Wilgotnosc wzgledna Wzorcowanie – wielkosci fizykochemiczne Porownanie z wzorcem wilgotnosci (10 do 60) °C od 10 % RH do 40 % RH CMC 0,9 % RH (10 do 60) °C od 40 % RH do 70 % RH CMC 1,0 % RH (10 do 60) °C od 70 % RH do 80 % RH CMC 1,1 % RH (10 do 60) °C od 80 % RH do 90 % RH CMC 1,2 % RH (10 do 60) °C od 90 % RH do 95 % RH CMC 1,6 % RH Relativni vlhkost Kalibrace – fyzikalne chemicke veliciny Porovnani s etalonem vlhkosti (10 az 60) °C 10 % RH az 40 % RH CMC 0,9 % RH (10 az 60) °C 40 % RH az 70 % RH CMC 1,0 % RH (10 az 60) °C 70 % RH az 80 % RH CMC 1,1 % RH (10 az 60) °C 80 % RH az 90 % RH CMC 1,2 % RH (10 az 60) °C 90 % RH az 95 % RH CMC 1,6 % RH KP-PB-99","search_en":"Relative humidity Calibration – physicochemical quantities Comparison with a humidity standard Uherský Brod II CMC for the field of measured quantity: Physicochemical quantities Comparison with a humidity standard (10 to 60) °C (10 to 60) °C (10 to 60) °C (10 to 60) °C (10 to 60) °C KP-PB-99","search_zh":"相对湿度 校准 – 物理化学量 与湿度标准器比较 乌赫尔斯基布罗德 II 被测量领域的CMC：物理化学量 与湿度标准器比较 (10 至 60) °C (10 至 60) °C (10 至 60) °C (10 至 60) °C (10 至 60) °C KP-PB-99","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":105,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"Uherský Brod II","methodology_de":"Kalibrierung – physikalisch-chemische Größen","parameters_de":[{"name":"(10 bis 60) °C","range":"von 10 % RH bis 40 % RH","cmc":"0,9 % RH"},{"name":"(10 bis 60) °C","range":"von 40 % RH bis 70 % RH","cmc":"1,0 % RH"},{"name":"(10 bis 60) °C","range":"von 70 % RH bis 80 % RH","cmc":"1,1 % RH"},{"name":"(10 bis 60) °C","range":"von 80 % RH bis 90 % RH","cmc":"1,2 % RH"},{"name":"(10 bis 60) °C","range":"von 90 % RH bis 95 % RH","cmc":"1,6 % RH"}],"regulatory_area_de":"CMC für den Messgrößenbereich: physikalisch-chemische Größen","search_de":"Relative Feuchte Kalibrierung – physikalisch-chemische Größen Vergleich mit einem Feuchtenormal Uherský Brod II CMC für den Messgrößenbereich: physikalisch-chemische Größen Vergleich mit einem Feuchtenormal (10 bis 60) °C (10 bis 60) °C (10 bis 60) °C (10 bis 60) °C (10 bis 60) °C KP-PB-99","technique_de":"Vergleich mit einem Feuchtenormal","techniques_de":["Vergleich mit einem Feuchtenormal"],"test_object_de":"Relative Feuchte"}],"has_pdf":true}