🇨🇿 M & B Calibr, spol. s r.o. PL

ČIA 2301 • Ivančice, Czech Republic • 82 calibration items

Metrology & calibration

M & B Calibr, spol. s r.o. is a calibration laboratory accredited by ČIA under number 2301 (Ivančice, Czech Republic). Its accreditation scope covers 82 calibration items in the following areas: Metrology & calibration. Calibrated items include: 3D coordinate measuring machines, Direct-indicating thermometers, Limit plug gauges, Thermoelectric temperature sensors. Most frequently used calibration principles: Direct generation with a standard calibrator, Direct and comparative measurement by a distance meter, Direct measurement by a standard multimeter.

At a glance

  • Accreditation number: ČIA 2301
  • Calibration items in scope: 82
  • Types of calibrated items: 65
  • Calibration principles used: 48
  • City: Ivančice, Czech Republic
  • Valid until: 02-07-2029
Accreditation number
2301
Accreditation body
ČIA
Address
Krumlovská 1454/26, 664 91 Ivančice
City
Ivančice, Czech Republic
Division
Laboratorium wzorcujące
Valid until
02-07-2029

What this laboratory calibrates (65)

Calibration principles (48)

Certificate information

Certificate date
26.09.2025

Accreditation scope — calibration items (82)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Parallel gauge blocks Calibration – length
0,5 mm to 1000 mm · CMC (2.L + 0,2) µm
CMC for the field of measured quantity: Length
Comparative measurement using parallel gauge blocks KP D1
2 Steel length gauges Calibration – length
0 m to 2 m · CMC 60 µm 2 m to 5 m · CMC 180 µm
CMC for the field of measured quantity: Length
Comparative measurement using parallel gauge blocks KP D2
3 Steel tape measures Calibration – length
0 m to 2 m · CMC 0,14 mm 2 m to 3 m · CMC 0,28 mm 3 m to 5 m · CMC 0,42 mm 5 m to 8 m · CMC 0,70 mm 8 m to 10 m · CMC 0,98 mm
CMC for the field of measured quantity: Length
Comparative measurement on a reference track KP D2
4 Tape measures Calibration – length
0 m to 10 m · CMC 0,4 mm 10 m to 20 m · CMC 0,6 mm 20 m to 50 m · CMC 1,0 mm 50 m to 100 m · CMC 2,2 mm
CMC for the field of measured quantity: Length
Comparative measurement on a reference track KP D3
5 Laser distance meters Calibration – length
0 m to 5 m · CMC 0,2 mm 5 m to 10 m · CMC 0,4 mm
CMC for the field of measured quantity: Length
Comparative measurement on a reference track KP D3
6 Rolling length gauges Calibration – length
0 m to 1000 m · CMC 0,4 %
CMC for the field of measured quantity: Length
Comparative measurement using a measuring tape KP D3
7 Limit and end measuring rings Calibration – length
1 mm to 100 mm · CMC (2.L + 0,5) µm 100 mm to 500 mm · CMC (2.L + 2,4) µm
CMC for the field of measured quantity: Length
Direct and comparative measurement by a distance meter KP D4
8 Limit snap gauges Calibration – length
1 mm to 100 mm · CMC (2.L + 0,5) µm 100 mm to 500 mm · CMC (2.L + 2,4) µm
CMC for the field of measured quantity: Length
Direct and comparative measurement by a distance meter KP D4
9 Feeler gauges Calibration – length
0,02 mm to 100 mm · CMC (2.L + 0,5) µm
CMC for the field of measured quantity: Length
Direct and comparative measurement by a distance meter KP D4
10 Limit cylindrical gauges Calibration – length
100 mm to 500 mm · CMC (2.L + 2,4) µm
CMC for the field of measured quantity: Length
Direct and comparative measurement by a distance meter KP D4
11 Feeler gauges, Limit cylindrical gauges Calibration – length
1 mm to 125 mm · CMC (2.L + 2,4) µm
CMC for the field of measured quantity: Length
Direct measurement by a micropasameter KP D4
12 Limit plug gauges Calibration – length
1 mm to 200 mm · CMC (3.L + 3) µm
CMC for the field of measured quantity: Length
Direct measurement by a distance meter KP D5
13 Limit plug gauges Calibration – length
1 mm to 160 mm · CMC (1.L + 4) µm
CMC for the field of measured quantity: Length
Direct measurement on MasterScanner XP 16060 KP D5
14 Threaded rings Calibration – length
1 mm to 3 mm · CMC (3.L + 3) µm
CMC for the field of measured quantity: Length
Comparison by a wear pin gauge KP D5
15 Threaded rings Calibration – length
2,5 mm to 200 mm · CMC (3.L + 3) µm
CMC for the field of measured quantity: Length
Indirect measurement by a distance meter KP D5
16 Threaded rings Calibration – length
3 mm to 160 mm · CMC (1.L + 4) µm
CMC for the field of measured quantity: Length
Direct measurement on MasterScanner XP 16060 KP D5
17 Limit plug gauges Calibration – length
1 mm to 125 mm · CMC (3.L + 3,5) µm
CMC for the field of measured quantity: Length
Direct measurement by a micropasameter KP D5
18 Slide gauges: slide rules, depth gauges, height gauges Calibration – length
0 mm to 1000 mm · CMC 12 µm 1000 mm to 3000 mm · CMC 20 µm
CMC for the field of measured quantity: Length
Comparative measurement using parallel gauge blocks and ring KP D6
19 Micrometer gauges: micrometers, pasameters, micropasameters, micrometer heads, micrometer depth gauges Calibration – length
0 mm to 25 mm · CMC 0,7 µm 25 mm to 100 mm · CMC 1,4 µm 100 mm to 1000 mm · CMC 2,5 µm 1000 mm to 1500 mm · CMC 4,1 µm
CMC for the field of measured quantity: Length
Comparative measurement using parallel gauge blocks KP D7
20 Inside micrometers Three contact internal gauges Calibration – length
2 mm to 100 mm · CMC 2,0 µm 100 mm to 300 mm · CMC 4,0 µm
CMC for the field of measured quantity: Length
Comparative measurement using setting rings KP D8
21 Inside micrometer gauges Calibration – length
10 mm to 3000 mm · CMC (3 L + 2,2) µm
CMC for the field of measured quantity: Length
Direct measurement by a distance meter KP D9
22 Electromagnetic, ultrasonic thickness gauges Calibration – length
0 mm to 1,5 mm · CMC (1.L + 1,3) µm 1,5 mm to 500 mm · CMC (1.L + 2,3) µm
CMC for the field of measured quantity: Length
Comparative measurement by a thickness reference standard KP D10
23 Direct and lever dial indicators Calibration – length
0 mm to 100 mm · CMC 0,3 µm
CMC for the field of measured quantity: Length
Direct measurement by a special measuring device KP D11
24 Two-contact internal gauges Calibration – length
2 mm to 205 mm · CMC 0,3 µm
CMC for the field of measured quantity: Length
Direct measurement by a special measuring device KP D11
25 Gauges, measuring jigs, templates, meters of plane and angle Calibration – length
0 mm to 2000 mm · CMC (4,5.L + 1,7) µm
CMC for the field of measured quantity: Length
Measurement by a 3D CMM KP D12
26 Profile projectors, measuring microscopes Calibration – length
0 mm to 600 mm · CMC (1.L + 2,6) µm
CMC for the field of measured quantity: Length
Comparative measurement using a rule KP D13
27 Measurement of straightness, linear sensing, measurement of flatness of engineering gauges Calibration – length
straightness — 0 m to 20 m · CMC (1.L + 0,1) µm flatness — 0 m to 20 m · CMC 1,5 µm/m²
CMC for the field of measured quantity: Length
Direct measurement by a laser interferometer KP D14
28 Gauges, measuring jigs, special meters Calibration – length
0 mm to 600 mm · CMC (2,5.L + 1,2) µm
CMC for the field of measured quantity: Length
Measurement by a linear height gauge KP D15
29 Linear height gauges Calibration – length
0 mm to 600 mm · CMC (0,8.L + 0,5) µm
CMC for the field of measured quantity: Length
Comparative measurement by a calibration comb KP D16
30 Linear height gauges Calibration – length
600 mm to 1000 mm · CMC (1.L + 3,0) µm
CMC for the field of measured quantity: Length
Comparative measurement by a calibration comb and parallel gauge blocks KP D16
31 Contourographs Calibration – length
0 mm to 100 mm · CMC (1.L + 2,6) µm
CMC for the field of measured quantity: Length
Comparative measurement using end standards KP D17
32 Length measuring instruments Calibration – length
0 mm to 20000 mm · CMC (2.L + 0,2) µm
CMC for the field of measured quantity: Length
Direct measurement by a laser interferometer KP D18
33 3D coordinate measuring machines Calibration – length
0 mm to 600 mm · CMC (2.L + 0,2) µm
CMC for the field of measured quantity: Length
Comparative measurement by a calibration comb KP D19
34 3D coordinate measuring machines Calibration – length
600 mm to 1000 mm · CMC (2.L + 0,2) µm
CMC for the field of measured quantity: Length
Comparative measurement by a calibration comb and parallel gauge blocks KP D19
35 3D coordinate measuring machines Calibration – length
0 mm to 10000 mm · CMC (1.L + 0,1) µm
CMC for the field of measured quantity: Length
Direct measurement by a laser interferometer KP D19
36 Gauges, special meters, measuring jigs, templates, rules Calibration – length
0 mm to 330 mm · CMC (2.L + 3,5) µm
CMC for the field of measured quantity: Length
Direct measurement by a 2D microscope KP D20
37 Blade and surface rules Calibration – length
0 mm to 2000 mm · CMC (5.L + 2) µm
CMC for the field of measured quantity: Length
Direct measurement on a plate KP D21
38 Blade and surface rules Calibration – length
2000 mm to 3000 mm · CMC (5.L + 12) µm
CMC for the field of measured quantity: Length
Measurement on a bed KP D21
39 Roughness meters Calibration – length
0,01 µm to 6000 µm · CMC 5 %
CMC for the field of measured quantity: Length
Comparative measurement by a roughness reference standard KP DR1
40 Roughness standards Calibration – length
0,01 µm to 6000 µm · CMC 5 %
CMC for the field of measured quantity: Length
Direct measurement by a roughness meter KP DR1
41 Angles from 0° to 180° Calibration – length
Length of the arm up to 3 m — 0 mm to 7 mm · CMC (4,5.L + 2) µm
CMC for the field of measured quantity: Length
Direct measurement by a 3D CMM KP R2
42 Levels – builder's, liquid, machine Calibration – plane angle
Division sensitivity from 0.01 mm/m — -52 mm/m to 52 mm/m · CMC 0,005 mm/m
CMC for the field of measured quantity: Plane angle
Direct measurement by a small angle generator KP R1
43 Clinometers Calibration – plane angle
Division from 0.01° — -180° to 180° · CMC 0,15°
CMC for the field of measured quantity: Plane angle
Direct measurement by a small angle generator KP R1
44 Angle gauges Calibration – plane angle
0° to 360° · CMC 5´
CMC for the field of measured quantity: Plane angle
Direct measurement using angle gauges KP R2
45 Piston pipettes Calibration – volume, flow rate
Distilled water — 0,5 µl to 10000 µl · CMC 0,13 % + 0,01 µl
CMC for the field of measured quantity: Volume, flow rate
Gravimetric method according to ČSN EN ISO 8655-6 KP P1
46 Non-automatic weighing instruments Calibration – mass
E2 class weight — 0,001 g to 2000 g · CMC 2,7.10⁻⁶ F2 class weight — 2 kg to 20 kg · CMC 1,4.10⁻⁵ M1 class weight — 20 kg to 1000 kg · CMC 5,0.10⁻⁵
CMC for the field of measured quantity: Mass
Reference weight loading (according to OIML R111-1:2004) KP VA1
47 Conventional weight of weights and objects Calibration – mass
1 g · CMC 0,4 mg 1 g to 2 g · CMC 0,5 mg 2 g to 5 g · CMC 0,6 mg 5 g to 10 g · CMC 0,7 mg 10 g to 20 g · CMC 0,9 mg 20 g to 50 g · CMC 1,2 mg 50 g to 100 g · CMC 1,9 mg 100 g to 200 g · CMC 2,8 mg 200 g to 500 g · CMC 5,1 mg 500 g to 1 kg · CMC 10 mg 1 kg to 2 kg · CMC 17 mg 2 kg to 5 kg · CMC 31 mg 5 kg to 10 kg · CMC 60 mg 10 kg to 20 kg · CMC 90 mg
CMC for the field of measured quantity: Mass
Comparison with a reference weight (according to OIML R111-1:2004) on the standard scales KP VA2
48 Revolution meters Calibration – rotational speed
30 min⁻¹ to 40000 min⁻¹ · CMC 1,1 %
CMC for the field of measured quantity: Rotational speed
Direct measurement by a revolution generator KP OT1
49 Hardness / Hardness plates and samples Calibration – force, mechanical tests
Rockwell — 70 HRA to 85 HRA · CMC 0,40 HRA Rockwell — 60 HRB to 100 HRB · CMC 0,40 HRB Rockwell — 20 HRC to 70 HRC · CMC 0,40 HRC
CMC for the field of measured quantity: Force, mechanical tests
Direct measurement KP TV1
50 Hardness / Hardness plates Calibration – force, mechanical tests
Shore A — 0 ShA to 100 ShA · CMC 2,0 ShA Shore D — 0 ShD to 100 ShD · CMC 2,0 ShD Brinell — 8 HBW to 650 HBW · CMC 1,0 % Vickers; HV2 to HV50 — 10 HV to 2900 HV · CMC 1,0 %
CMC for the field of measured quantity: Force, mechanical tests
Direct measurement KP TV1
51 Hardness / Hardness meters for metals Calibration – force, mechanical tests
Rockwell — 70 HRA to 85 HRA · CMC 0,50 HRA Rockwell — 60 HRB to 100 HRB · CMC 0,50 HRB Rockwell — 20 HRC to 70 HRC · CMC 0,50 HRC Vickers — 10 HV to 2000 HV · CMC 0,50 % Brinell — 10 HBW to 650 HBW · CMC 0,50 %
CMC for the field of measured quantity: Force, mechanical tests
Direct measurement using reference hardness plates KP TV1
52 Hardness / Shore hardness meters, type A,D,E,C Calibration – force, mechanical tests
1 Sh to 100 Sh · CMC 0,50 Sh
CMC for the field of measured quantity: Force, mechanical tests
Direct measurement using reference hardness plates KP TV1
53 Torque / Torque wrenches Calibration – force, mechanical tests
0,1 Nm to 1100 Nm · CMC 0,65 % 1100 Nm to 3000 Nm · CMC 0,90 %
CMC for the field of measured quantity: Force, mechanical tests
Comparative measurement by a reference torque sensor KP S1
54 Torque / Torque measuring devices, torque drivers, torque sensors Calibration – force, mechanical tests
0,1 Nm to 500 Nm · CMC 0,40 % 500 Nm to 2000 Nm · CMC 1,05 %
CMC for the field of measured quantity: Force, mechanical tests
Comparative measurement by a reference torque sensor KP S1
55 Moment of force / Force meters and extensometric sensors Calibration – force, mechanical tests
0,001 N to 5 kN · CMC 0,20 % 5 kN to 30 kN · CMC 0,30 %
CMC for the field of measured quantity: Force, mechanical tests
Comparative measurement by a reference force sensor KP S2
56 Moment of force / Force meters and extensometric sensors Calibration – force, mechanical tests
0,001 N to 5 kN · CMC 0,20 % 5 kN to 20 kN · CMC 0,30 %
CMC for the field of measured quantity: Force, mechanical tests
Comparative measurement by a reference force sensor KP S2
57 Deformation manometers, tyre pressure gauges, electromechanical pressure gauges (digital pressure gauges, pressure transducers with digital output of the measured quantity) Calibration – pressure
Gas; Absolute pressure — 0 kPa to 7 MPa · CMC 0,05 % + 100 Pa Gas; Overpressure — -100 kPa to -1 kPa · CMC 130 Pa Gas; Overpressure — -1 kPa to 1 kPa · CMC 3,2 Pa Gas; Overpressure — 1 kPa to 35 kPa · CMC 18 Pa Gas; Overpressure — 35 kPa to 7 MPa · CMC 0,05 % Liquids; Absolute pressure — 0 kPa to 7 MPa · CMC 0,05 % + 100 Pa Liquids; Absolute pressure — 7 MPa to 70 MPa · CMC 0,05 % Liquids; Absolute pressure — 70 MPa to 140 MPa · CMC 0,2 % Liquids; Overpressure — 0 MPa to 1,4 MPa · CMC 1,4 kPa Liquids; Overpressure — 1,4 MPa to 70 MPa · CMC 0,05 % Liquids; Overpressure — 70 MPa to 140 MPa · CMC 0,2 %
CMC for the field of measured quantity: Pressure
Comparative measurement by a reference digital pressure gauge KP T1, KP T2
58 Direct-indicating thermometers Calibration – temperature
-50 °C to 0 °C · CMC 0,14 °C 100 °C to 200 °C · CMC 0,22 °C 200 °C to 300 °C · CMC 0,32 °C 300 °C to 400 °C · CMC 0,42 °C 400 °C to 500 °C · CMC 0,52 °C 500 °C to 650 °C · CMC 0,67 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in a dry block calibrator KP TE1
59 Direct-indicating thermometers Calibration – temperature
0 °C to 100 °C · CMC 0,08 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in a liquid bath KP TE1
60 Direct-indicating thermometers Calibration – temperature
650 °C to 1100 °C · CMC 1,5 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in an air oven KP TE1
61 Contactless thermometers Calibration – temperature
-10 °C to 200 °C · CMC 3,0 °C 200 °C to 500 °C · CMC 6,0 °C 500 °C to 800 °C · CMC 10,0 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference pyrometer on target-type or cavity-type black body KP TE4
62 Thermoelectric temperature sensors Calibration – temperature
-50 °C to 0 °C · CMC 0,7 °C 100 °C to 550 °C · CMC 0,9 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in a dry block calibrator KP TE2
63 Thermoelectric temperature sensors Calibration – temperature
0 °C to 100 °C · CMC 0,7 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in a liquid bath KP TE2
64 Thermoelectric temperature sensors Calibration – temperature
550 °C to 800 °C · CMC 2,3 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in an air oven KP TE2
65 Resistance temperature sensors Calibration – temperature
-50 °C to 0 °C · CMC 0,15 °C 100 °C to 400 °C · CMC 0,45 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in a dry block calibrator KP TE3
66 Resistance temperature sensors Calibration – temperature
0 °C to 100 °C · CMC 0,13 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference digital thermometer in a liquid bath KP TE3
67 DC voltage / DC voltage sources Calibration – electrical quantities
0 mV to 100 mV · CMC 0,0062 % + 6,1 µV 0,1 V to 1 V · CMC 0,0047 % + 16 µV 1 V to 10 V · CMC 0,0047 % + 0,14 mV 10 V to 100 V · CMC 0,0079 % + 2,0 mV 100 V to 1000 V · CMC 0,0079 % + 20 mV
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a standard multimeter KP EL2
68 DC voltage / DC voltage meters Calibration – electrical quantities
0 mV to 200 mV · CMC 0,0053 % + 7,7 µV 0,2 V to 2 V · CMC 0,0028 % + 15 µV 2 V to 20 V · CMC 0,0028 % + 0,15 mV 20 V to 200 V · CMC 0,0028 % + 1,5 mV 200 V to 1000 V · CMC 0,0035 % + 17 mV
CMC for the field of measured quantity: Electrical quantities
Direct generation with a standard calibrator KP EL1
69 Direct current / Direct current sources Calibration – electrical quantities
0 µA to 10 µA · CMC 0,050 % + 6,1 nA 10 µA to 100 µA · CMC 0,074 % + 17 nA 0,1 mA to 1 mA · CMC 0,075 % + 0,16 µA 1 mA to 10 mA · CMC 0,034 % + 1,2 µA 10 mA to 100 mA · CMC 0,034 % + 12 µA 100 mA to 1 A · CMC 0,068 % + 0,15 mA 1 A to 3 A · CMC 0,061 % + 1,1 mA
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a standard multimeter KP EL2
70 Direct current / Direct current meters Calibration – electrical quantities
0 µA to 200 µA · CMC 0,020 % + 73 nA 0,2 mA to 2 mA · CMC 0,016 % + 0,13 µA 2 mA to 20 mA · CMC 0,009 % + 0,94 µA 20 mA to 200 mA · CMC 0,012 % + 9,7 µA 0,2 A to 2 A · CMC 0,018 % + 0,13 mA 2 A to 30 A · CMC 0,069 % + 2,5 mA
CMC for the field of measured quantity: Electrical quantities
Direct generation with a standard calibrator KP EL1
71 Direct current / Direct current meters Calibration – electrical quantities
30 A to 1500 A · CMC 0,42 % + 0,13 A
CMC for the field of measured quantity: Electrical quantities
Simulation using current coil KP EL1
72 AC voltage / AC voltage sources Calibration – electrical quantities
10 Hz to 20 kHz — 0,1 mV to 100 mV · CMC 0,086 % + 36 µV 20 kHz to 50 kHz — 0,1 mV to 100 mV · CMC 0,16 % + 59 µV 50 kHz to 100 kHz — 0,1 mV to 100 mV · CMC 0,69 % + 93 µV 10 Hz to 20 kHz — 0,1 V to 1 V · CMC 0,076 % + 0,43 mV 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 0,14 % + 0,73 mV 50 kHz to 100 kHz — 0,1 V to 1 V · CMC 0,71 % + 0,81 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 0,076 % + 4,4 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 0,14 % + 7,3 mV 50 kHz to 100 kHz — 1 V to 10 V · CMC 0,71 % + 17 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 0,076 % + 44 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 0,14 % + 73 mV 50 kHz to 100 kHz — 10 V to 100 V · CMC 0,71 % + 81 mV 10 Hz to 20 kHz — 100 V to 750 V · CMC 0,07 % + 0,35 V 20 kHz to 50 kHz — 100 V to 750 V · CMC 0,14 % + 0,59 V 50 kHz to 100 kHz — 100 V to 750 V · CMC 0,61 % + 1,5 V
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a standard multimeter KP EL2
73 AC voltage / AC voltage meters Calibration – electrical quantities
10 Hz to 45 Hz — 0,1 mV to 200 mV · CMC 0,16 % + 64 µV 45 Hz to 10 kHz — 0,1 mV to 200 mV · CMC 0,049 % + 69 µV 10 kHz to 20 kHz — 0,1 mV to 200 mV · CMC 0,12 % + 86 µV 20 kHz to 50 kHz — 0,1 mV to 200 mV · CMC 0,20 % + 98 µV 10 Hz to 45 Hz — 0,2 V to 2 V · CMC 0,082 % + 0,38 mV 45 Hz to 10 kHz — 0,2 V to 2 V · CMC 0,042 % + 0,29 mV 10 kHz to 20 kHz — 0,2 V to 2 V · CMC 0,12 % + 0,46 mV 20 kHz to 50 kHz — 0,2 V to 2 V · CMC 0,17 % + 0,73 mV 10 Hz to 45 Hz — 2 V to 20 V · CMC 0,084 % + 3,8 mV 45 Hz to 10 kHz — 2 V to 20 V · CMC 0,042 % + 2,7 mV 10 kHz to 20 kHz — 2 V to 20 V · CMC 0,12 % + 4,7 mV 20 kHz to 50 kHz — 2 V to 20 V · CMC 0,17 % + 5,6 mV 30 Hz to 45 Hz — 20 V to 200 V · CMC 0,082 % + 31 mV 45 Hz to 10 kHz — 20 V to 200 V · CMC 0,10 % + 43 mV 10 kHz to 20 kHz — 20 V to 200 V · CMC 0,14 % + 56 mV 20 kHz to 40 kHz — 20 V to 200 V · CMC 0,17 % + 61 mV 30 Hz to 45 Hz — 200 V to 1000 V · CMC 0,082 % + 0,45 V 45 Hz to 1 kHz — 200 V to 1000 V · CMC 0,09 % + 0,28 V 1 kHz to 5 kHz — 200 V to 1000 V · CMC 0,14 % + 0,38 V 5 kHz to 10 kHz — 200 V to 1000 V · CMC 0,16 % + 0,49 V
CMC for the field of measured quantity: Electrical quantities
Direct generation with a standard calibrator KP EL1
74 Alternating current / Alternating current sources Calibration – electrical quantities
10 Hz to 1 kHz — 0,1 µA to 100 µA · CMC 0,15 % + 7,3 nA 10 Hz to 5 kHz — 0,1 mA to 1 mA · CMC 0,10 % + 0,51 µA 10 Hz to 5 kHz — 1 mA to 10 mA · CMC 0,10 % + 5,1 µA 10 Hz to 5 kHz — 10 mA to 100 mA · CMC 0,10 % + 51 µA 10 Hz to 5 kHz — 0,1 A to 1 A · CMC 0,10 % + 0,51 mA 10 Hz to 5 kHz — 1 A to 3 A · CMC 0,15 % + 3,4 mA
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a standard multimeter KP EL2
75 Alternating current / Alternating current meters Calibration – electrical quantities
10 Hz to 45 Hz — 20 µA to 200 µA · CMC 0,25 % + 0,40 µA 45 Hz to 1 kHz — 20 µA to 200 µA · CMC 0,08 % + 0,30 µA 10 Hz to 45 Hz — 0,2 mA to 2 mA · CMC 0,23 % + 0,40 µA 45 Hz to 1 kHz — 0,2 mA to 2 mA · CMC 0,06 % + 0,30 µA 10 Hz to 45 Hz — 2 mA to 20 mA · CMC 0,23 % + 4,5 µA 45 Hz to 1 kHz — 2 mA to 20 mA · CMC 0,05 % + 3,0 µA 10 Hz to 45 Hz — 20 mA to 200 mA · CMC 0,23 % + 45 µA 45 Hz to 1 kHz — 20 mA to 200 mA · CMC 0,05 % + 30 µA 10 Hz to 45 Hz — 0,2 A to 2 A · CMC 0,23 % + 0,45 mA 45 Hz to 1 kHz — 0,2 A to 2 A · CMC 0,06 % + 0,30 mA 30 Hz to 45 Hz — 2 A to 30 A · CMC 0,23 % + 4,5 mA 45 Hz to 100 Hz — 2 A to 30 A · CMC 0,06 % + 3,0 mA 100 Hz to 1 kHz — 2 A to 30 A · CMC 0,60 % + 5,8 mA
CMC for the field of measured quantity: Electrical quantities
Direct generation with a standard calibrator KP EL1
76 Alternating current / Alternating current meters Calibration – electrical quantities
30 Hz to 60 Hz — 30 A to 1500 A · CMC 0,42 % + 0,13 A
CMC for the field of measured quantity: Electrical quantities
Simulation using current coil KP EL1
77 DC resistance / DC resistance meters Calibration – electrical quantities
0,1 Ω · CMC 8,7 mΩ 1 Ω · CMC 8,9 mΩ 10 Ω · CMC 11 mΩ 100 Ω · CMC 20 mΩ 1 kΩ · CMC 0,16 Ω 10 kΩ · CMC 1,6 Ω 100 kΩ · CMC 15 Ω 1 MΩ · CMC 0,29 kΩ 10 MΩ · CMC 8,0 kΩ 100 MΩ · CMC 0,98 MΩ 1 GΩ · CMC 22 MΩ 0 Ω to 100 Ω · CMC 0,018 % + 88 mΩ 100 Ω to 330 Ω · CMC 0,012 % + 0,11 Ω 330 Ω to 1 kΩ · CMC 0,01 % + 0,19 Ω 1 kΩ to 3,3 kΩ · CMC 0,012 % + 0,29 Ω 3,3 kΩ to 10 kΩ · CMC 0,0082 % + 1,4 Ω 10 kΩ to 33 kΩ · CMC 0,012 % + 2,2 Ω 33 kΩ to 100 kΩ · CMC 0,0066 % + 18 Ω 100 kΩ to 330 kΩ · CMC 0,011 % + 24 Ω 330 kΩ to 1 MΩ · CMC 0,0066 % + 0,18 kΩ 1 MΩ to 3,3 MΩ · CMC 0,013 % + 0,24 kΩ 3,3 MΩ to 10 MΩ · CMC 0,0075 % + 1,8 kΩ 10 MΩ to 33 MΩ · CMC 0,052 % + 6,4 kΩ 33 MΩ to 100 MΩ · CMC 0,064 % + 0,21 MΩ 100 MΩ to 330 MΩ · CMC 1,3 % + 1,9 MΩ 330 MΩ to 1 GΩ · CMC 2,4 % + 13 MΩ
CMC for the field of measured quantity: Electrical quantities
Direct generation with a standard calibrator KP EL 1
78 Capacitance / Electrical Capacitance Meters Calibration – electrical quantities
1 kHz — 1 nF · CMC 0,48 % 1 kHz — 2 nF · CMC 0,73 % 1 kHz — 5 nF · CMC 0,70 % 1 kHz — 10 nF · CMC 0,54 % 1 kHz — 100 nF · CMC 0,41 % 1 kHz — 1 µF · CMC 0,65 % 1 kHz — 10 µF · CMC 0,98 %
CMC for the field of measured quantity: Electrical quantities
Direct generation with a standard calibrator KP EL1
79 Capacitance / Electrical Capacitance Meters Calibration – electrical quantities
10 µF to 100 µF · CMC 1,2 %
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard multimeter KP EL1
80 Time interval / time meters, stopwatches, timers Calibration – time quantities and frequency
1 s to 86400 s · CMC 0,5 s
CMC for the field of measured quantity: Time quantities and frequency
Comparison with a reference digital stopwatch KP Č1
81 Frequency / low frequency and high frequency counters Calibration – time quantities and frequency
1 Hz to 100 kHz · CMC 1,7.10⁻⁶ 100 kHz to 1000 kHz · CMC 2,3.10⁻⁶ 10 MHz · CMC 1,7.10⁻⁵
CMC for the field of measured quantity: Time quantities and frequency
Direct generation by reference calibrator KP EL1
82 Relative humidity meters except psychrometers Calibration – humidity
(20 to 40) °C — 10 % RH to 95 % RH · CMC 2,3 % RH
CMC for the field of measured quantity: Humidity
Comparative measurement by a reference hygrometer in a humidity generator KP VL1

Reference standards (42)

KP D1
KP D10
KP D11
KP D12
KP D13
KP D14
KP D15
KP D16
KP D17
KP D18
KP D19
KP D2
KP D20
KP D21
KP D3
KP D4
KP D5
KP D6
KP D7
KP D8
KP D9
KP DR1
KP EL 1
KP EL1
KP EL2
KP OT1
KP P1
KP R1
KP R2
KP S1
KP S2
KP T1
KP T2
KP TE1
KP TE2
KP TE3
KP TE4
KP TV1
KP VA1
KP VA2
KP VL1
KP Č1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2301