🇨🇿 M & B Calibr, spol. s r.o. PL
Metrology & calibration
M & B Calibr, spol. s r.o. is a calibration laboratory accredited by ČIA under number 2301 (Ivančice, Czech Republic). Its accreditation scope covers 82 calibration items in the following areas: Metrology & calibration. Calibrated items include: 3D coordinate measuring machines, Direct-indicating thermometers, Limit plug gauges, Thermoelectric temperature sensors. Most frequently used calibration principles: Direct generation with a standard calibrator, Direct and comparative measurement by a distance meter, Direct measurement by a standard multimeter.
At a glance
- Accreditation number: ČIA 2301
- Calibration items in scope: 82
- Types of calibrated items: 65
- Calibration principles used: 48
- City: Ivančice, Czech Republic
- Valid until: 02-07-2029
- Accreditation number
- 2301
- Accreditation body
- ČIA
- Address
- Krumlovská 1454/26, 664 91 Ivančice
- City
- Ivančice, Czech Republic
- Division
- Laboratorium wzorcujące
- Valid until
- 02-07-2029
What this laboratory calibrates (65)
- 3D coordinate measuring machines — 3 calibration items
- Direct-indicating thermometers — 3 calibration items
- Limit plug gauges — 3 calibration items
- Thermoelectric temperature sensors — 3 calibration items
- Threaded rings — 3 calibration items
- Alternating current / Alternating current meters — 2 calibration items
- Blade and surface rules — 2 calibration items
- Capacitance / Electrical Capacitance Meters — 2 calibration items
- Direct current / Direct current meters — 2 calibration items
- Linear height gauges — 2 calibration items
- Moment of force / Force meters and extensometric sensors — 2 calibration items
- Resistance temperature sensors — 2 calibration items
- AC voltage / AC voltage meters — 1 calibration item
- AC voltage / AC voltage sources — 1 calibration item
- Alternating current / Alternating current sources — 1 calibration item
- and 50 more
Calibration principles (48)
- Direct generation with a standard calibrator — 6 calibration items
- Direct and comparative measurement by a distance meter — 4 calibration items
- Direct measurement by a standard multimeter — 4 calibration items
- Comparative measurement on a reference track — 3 calibration items
- Comparative measurement using parallel gauge blocks — 3 calibration items
- Comparison with a reference digital thermometer in a dry block calibrator — 3 calibration items
- Comparison with a reference digital thermometer in a liquid bath — 3 calibration items
- Direct measurement by a laser interferometer — 3 calibration items
- Comparative measurement by a calibration comb — 2 calibration items
- Comparative measurement by a calibration comb and parallel gauge blocks — 2 calibration items
- Comparative measurement by a reference force sensor — 2 calibration items
- Comparative measurement by a reference torque sensor — 2 calibration items
- Comparison with a reference digital thermometer in an air oven — 2 calibration items
- Direct measurement — 2 calibration items
- Direct measurement by a distance meter — 2 calibration items
- and 33 more
Certificate information
- Certificate date
- 26.09.2025
Accreditation scope — calibration items (82)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Parallel gauge blocks | Calibration – length 0,5 mm to 1000 mm · CMC (2.L + 0,2) µm CMC for the field of measured quantity: Length |
Comparative measurement using parallel gauge blocks | KP D1 | |
| 2 | Steel length gauges | Calibration – length 0 m to 2 m · CMC 60 µm 2 m to 5 m · CMC 180 µm CMC for the field of measured quantity: Length |
Comparative measurement using parallel gauge blocks | KP D2 | |
| 3 | Steel tape measures | Calibration – length 0 m to 2 m · CMC 0,14 mm 2 m to 3 m · CMC 0,28 mm 3 m to 5 m · CMC 0,42 mm 5 m to 8 m · CMC 0,70 mm 8 m to 10 m · CMC 0,98 mm CMC for the field of measured quantity: Length |
Comparative measurement on a reference track | KP D2 | |
| 4 | Tape measures | Calibration – length 0 m to 10 m · CMC 0,4 mm 10 m to 20 m · CMC 0,6 mm 20 m to 50 m · CMC 1,0 mm 50 m to 100 m · CMC 2,2 mm CMC for the field of measured quantity: Length |
Comparative measurement on a reference track | KP D3 | |
| 5 | Laser distance meters | Calibration – length 0 m to 5 m · CMC 0,2 mm 5 m to 10 m · CMC 0,4 mm CMC for the field of measured quantity: Length |
Comparative measurement on a reference track | KP D3 | |
| 6 | Rolling length gauges | Calibration – length 0 m to 1000 m · CMC 0,4 % CMC for the field of measured quantity: Length |
Comparative measurement using a measuring tape | KP D3 | |
| 7 | Limit and end measuring rings | Calibration – length 1 mm to 100 mm · CMC (2.L + 0,5) µm 100 mm to 500 mm · CMC (2.L + 2,4) µm CMC for the field of measured quantity: Length |
Direct and comparative measurement by a distance meter | KP D4 | |
| 8 | Limit snap gauges | Calibration – length 1 mm to 100 mm · CMC (2.L + 0,5) µm 100 mm to 500 mm · CMC (2.L + 2,4) µm CMC for the field of measured quantity: Length |
Direct and comparative measurement by a distance meter | KP D4 | |
| 9 | Feeler gauges | Calibration – length 0,02 mm to 100 mm · CMC (2.L + 0,5) µm CMC for the field of measured quantity: Length |
Direct and comparative measurement by a distance meter | KP D4 | |
| 10 | Limit cylindrical gauges | Calibration – length 100 mm to 500 mm · CMC (2.L + 2,4) µm CMC for the field of measured quantity: Length |
Direct and comparative measurement by a distance meter | KP D4 | |
| 11 | Feeler gauges, Limit cylindrical gauges | Calibration – length 1 mm to 125 mm · CMC (2.L + 2,4) µm CMC for the field of measured quantity: Length |
Direct measurement by a micropasameter | KP D4 | |
| 12 | Limit plug gauges | Calibration – length 1 mm to 200 mm · CMC (3.L + 3) µm CMC for the field of measured quantity: Length |
Direct measurement by a distance meter | KP D5 | |
| 13 | Limit plug gauges | Calibration – length 1 mm to 160 mm · CMC (1.L + 4) µm CMC for the field of measured quantity: Length |
Direct measurement on MasterScanner XP 16060 | KP D5 | |
| 14 | Threaded rings | Calibration – length 1 mm to 3 mm · CMC (3.L + 3) µm CMC for the field of measured quantity: Length |
Comparison by a wear pin gauge | KP D5 | |
| 15 | Threaded rings | Calibration – length 2,5 mm to 200 mm · CMC (3.L + 3) µm CMC for the field of measured quantity: Length |
Indirect measurement by a distance meter | KP D5 | |
| 16 | Threaded rings | Calibration – length 3 mm to 160 mm · CMC (1.L + 4) µm CMC for the field of measured quantity: Length |
Direct measurement on MasterScanner XP 16060 | KP D5 | |
| 17 | Limit plug gauges | Calibration – length 1 mm to 125 mm · CMC (3.L + 3,5) µm CMC for the field of measured quantity: Length |
Direct measurement by a micropasameter | KP D5 | |
| 18 | Slide gauges: slide rules, depth gauges, height gauges | Calibration – length 0 mm to 1000 mm · CMC 12 µm 1000 mm to 3000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
Comparative measurement using parallel gauge blocks and ring | KP D6 | |
| 19 | Micrometer gauges: micrometers, pasameters, micropasameters, micrometer heads, micrometer depth gauges | Calibration – length 0 mm to 25 mm · CMC 0,7 µm 25 mm to 100 mm · CMC 1,4 µm 100 mm to 1000 mm · CMC 2,5 µm 1000 mm to 1500 mm · CMC 4,1 µm CMC for the field of measured quantity: Length |
Comparative measurement using parallel gauge blocks | KP D7 | |
| 20 | Inside micrometers Three contact internal gauges | Calibration – length 2 mm to 100 mm · CMC 2,0 µm 100 mm to 300 mm · CMC 4,0 µm CMC for the field of measured quantity: Length |
Comparative measurement using setting rings | KP D8 | |
| 21 | Inside micrometer gauges | Calibration – length 10 mm to 3000 mm · CMC (3 L + 2,2) µm CMC for the field of measured quantity: Length |
Direct measurement by a distance meter | KP D9 | |
| 22 | Electromagnetic, ultrasonic thickness gauges | Calibration – length 0 mm to 1,5 mm · CMC (1.L + 1,3) µm 1,5 mm to 500 mm · CMC (1.L + 2,3) µm CMC for the field of measured quantity: Length |
Comparative measurement by a thickness reference standard | KP D10 | |
| 23 | Direct and lever dial indicators | Calibration – length 0 mm to 100 mm · CMC 0,3 µm CMC for the field of measured quantity: Length |
Direct measurement by a special measuring device | KP D11 | |
| 24 | Two-contact internal gauges | Calibration – length 2 mm to 205 mm · CMC 0,3 µm CMC for the field of measured quantity: Length |
Direct measurement by a special measuring device | KP D11 | |
| 25 | Gauges, measuring jigs, templates, meters of plane and angle | Calibration – length 0 mm to 2000 mm · CMC (4,5.L + 1,7) µm CMC for the field of measured quantity: Length |
Measurement by a 3D CMM | KP D12 | |
| 26 | Profile projectors, measuring microscopes | Calibration – length 0 mm to 600 mm · CMC (1.L + 2,6) µm CMC for the field of measured quantity: Length |
Comparative measurement using a rule | KP D13 | |
| 27 | Measurement of straightness, linear sensing, measurement of flatness of engineering gauges | Calibration – length straightness — 0 m to 20 m · CMC (1.L + 0,1) µm flatness — 0 m to 20 m · CMC 1,5 µm/m² CMC for the field of measured quantity: Length |
Direct measurement by a laser interferometer | KP D14 | |
| 28 | Gauges, measuring jigs, special meters | Calibration – length 0 mm to 600 mm · CMC (2,5.L + 1,2) µm CMC for the field of measured quantity: Length |
Measurement by a linear height gauge | KP D15 | |
| 29 | Linear height gauges | Calibration – length 0 mm to 600 mm · CMC (0,8.L + 0,5) µm CMC for the field of measured quantity: Length |
Comparative measurement by a calibration comb | KP D16 | |
| 30 | Linear height gauges | Calibration – length 600 mm to 1000 mm · CMC (1.L + 3,0) µm CMC for the field of measured quantity: Length |
Comparative measurement by a calibration comb and parallel gauge blocks | KP D16 | |
| 31 | Contourographs | Calibration – length 0 mm to 100 mm · CMC (1.L + 2,6) µm CMC for the field of measured quantity: Length |
Comparative measurement using end standards | KP D17 | |
| 32 | Length measuring instruments | Calibration – length 0 mm to 20000 mm · CMC (2.L + 0,2) µm CMC for the field of measured quantity: Length |
Direct measurement by a laser interferometer | KP D18 | |
| 33 | 3D coordinate measuring machines | Calibration – length 0 mm to 600 mm · CMC (2.L + 0,2) µm CMC for the field of measured quantity: Length |
Comparative measurement by a calibration comb | KP D19 | |
| 34 | 3D coordinate measuring machines | Calibration – length 600 mm to 1000 mm · CMC (2.L + 0,2) µm CMC for the field of measured quantity: Length |
Comparative measurement by a calibration comb and parallel gauge blocks | KP D19 | |
| 35 | 3D coordinate measuring machines | Calibration – length 0 mm to 10000 mm · CMC (1.L + 0,1) µm CMC for the field of measured quantity: Length |
Direct measurement by a laser interferometer | KP D19 | |
| 36 | Gauges, special meters, measuring jigs, templates, rules | Calibration – length 0 mm to 330 mm · CMC (2.L + 3,5) µm CMC for the field of measured quantity: Length |
Direct measurement by a 2D microscope | KP D20 | |
| 37 | Blade and surface rules | Calibration – length 0 mm to 2000 mm · CMC (5.L + 2) µm CMC for the field of measured quantity: Length |
Direct measurement on a plate | KP D21 | |
| 38 | Blade and surface rules | Calibration – length 2000 mm to 3000 mm · CMC (5.L + 12) µm CMC for the field of measured quantity: Length |
Measurement on a bed | KP D21 | |
| 39 | Roughness meters | Calibration – length 0,01 µm to 6000 µm · CMC 5 % CMC for the field of measured quantity: Length |
Comparative measurement by a roughness reference standard | KP DR1 | |
| 40 | Roughness standards | Calibration – length 0,01 µm to 6000 µm · CMC 5 % CMC for the field of measured quantity: Length |
Direct measurement by a roughness meter | KP DR1 | |
| 41 | Angles from 0° to 180° | Calibration – length Length of the arm up to 3 m — 0 mm to 7 mm · CMC (4,5.L + 2) µm CMC for the field of measured quantity: Length |
Direct measurement by a 3D CMM | KP R2 | |
| 42 | Levels – builder's, liquid, machine | Calibration – plane angle Division sensitivity from 0.01 mm/m — -52 mm/m to 52 mm/m · CMC 0,005 mm/m CMC for the field of measured quantity: Plane angle |
Direct measurement by a small angle generator | KP R1 | |
| 43 | Clinometers | Calibration – plane angle Division from 0.01° — -180° to 180° · CMC 0,15° CMC for the field of measured quantity: Plane angle |
Direct measurement by a small angle generator | KP R1 | |
| 44 | Angle gauges | Calibration – plane angle 0° to 360° · CMC 5´ CMC for the field of measured quantity: Plane angle |
Direct measurement using angle gauges | KP R2 | |
| 45 | Piston pipettes | Calibration – volume, flow rate Distilled water — 0,5 µl to 10000 µl · CMC 0,13 % + 0,01 µl CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method according to ČSN EN ISO 8655-6 | KP P1 | |
| 46 | Non-automatic weighing instruments | Calibration – mass E2 class weight — 0,001 g to 2000 g · CMC 2,7.10⁻⁶ F2 class weight — 2 kg to 20 kg · CMC 1,4.10⁻⁵ M1 class weight — 20 kg to 1000 kg · CMC 5,0.10⁻⁵ CMC for the field of measured quantity: Mass |
Reference weight loading (according to OIML R111-1:2004) | KP VA1 | |
| 47 | Conventional weight of weights and objects | Calibration – mass 1 g · CMC 0,4 mg 1 g to 2 g · CMC 0,5 mg 2 g to 5 g · CMC 0,6 mg 5 g to 10 g · CMC 0,7 mg 10 g to 20 g · CMC 0,9 mg 20 g to 50 g · CMC 1,2 mg 50 g to 100 g · CMC 1,9 mg 100 g to 200 g · CMC 2,8 mg 200 g to 500 g · CMC 5,1 mg 500 g to 1 kg · CMC 10 mg 1 kg to 2 kg · CMC 17 mg 2 kg to 5 kg · CMC 31 mg 5 kg to 10 kg · CMC 60 mg 10 kg to 20 kg · CMC 90 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight (according to OIML R111-1:2004) on the standard scales | KP VA2 | |
| 48 | Revolution meters | Calibration – rotational speed 30 min⁻¹ to 40000 min⁻¹ · CMC 1,1 % CMC for the field of measured quantity: Rotational speed |
Direct measurement by a revolution generator | KP OT1 | |
| 49 | Hardness / Hardness plates and samples | Calibration – force, mechanical tests Rockwell — 70 HRA to 85 HRA · CMC 0,40 HRA Rockwell — 60 HRB to 100 HRB · CMC 0,40 HRB Rockwell — 20 HRC to 70 HRC · CMC 0,40 HRC CMC for the field of measured quantity: Force, mechanical tests |
Direct measurement | KP TV1 | |
| 50 | Hardness / Hardness plates | Calibration – force, mechanical tests Shore A — 0 ShA to 100 ShA · CMC 2,0 ShA Shore D — 0 ShD to 100 ShD · CMC 2,0 ShD Brinell — 8 HBW to 650 HBW · CMC 1,0 % Vickers; HV2 to HV50 — 10 HV to 2900 HV · CMC 1,0 % CMC for the field of measured quantity: Force, mechanical tests |
Direct measurement | KP TV1 | |
| 51 | Hardness / Hardness meters for metals | Calibration – force, mechanical tests Rockwell — 70 HRA to 85 HRA · CMC 0,50 HRA Rockwell — 60 HRB to 100 HRB · CMC 0,50 HRB Rockwell — 20 HRC to 70 HRC · CMC 0,50 HRC Vickers — 10 HV to 2000 HV · CMC 0,50 % Brinell — 10 HBW to 650 HBW · CMC 0,50 % CMC for the field of measured quantity: Force, mechanical tests |
Direct measurement using reference hardness plates | KP TV1 | |
| 52 | Hardness / Shore hardness meters, type A,D,E,C | Calibration – force, mechanical tests 1 Sh to 100 Sh · CMC 0,50 Sh CMC for the field of measured quantity: Force, mechanical tests |
Direct measurement using reference hardness plates | KP TV1 | |
| 53 | Torque / Torque wrenches | Calibration – force, mechanical tests 0,1 Nm to 1100 Nm · CMC 0,65 % 1100 Nm to 3000 Nm · CMC 0,90 % CMC for the field of measured quantity: Force, mechanical tests |
Comparative measurement by a reference torque sensor | KP S1 | |
| 54 | Torque / Torque measuring devices, torque drivers, torque sensors | Calibration – force, mechanical tests 0,1 Nm to 500 Nm · CMC 0,40 % 500 Nm to 2000 Nm · CMC 1,05 % CMC for the field of measured quantity: Force, mechanical tests |
Comparative measurement by a reference torque sensor | KP S1 | |
| 55 | Moment of force / Force meters and extensometric sensors | Calibration – force, mechanical tests 0,001 N to 5 kN · CMC 0,20 % 5 kN to 30 kN · CMC 0,30 % CMC for the field of measured quantity: Force, mechanical tests |
Comparative measurement by a reference force sensor | KP S2 | |
| 56 | Moment of force / Force meters and extensometric sensors | Calibration – force, mechanical tests 0,001 N to 5 kN · CMC 0,20 % 5 kN to 20 kN · CMC 0,30 % CMC for the field of measured quantity: Force, mechanical tests |
Comparative measurement by a reference force sensor | KP S2 | |
| 57 | Deformation manometers, tyre pressure gauges, electromechanical pressure gauges (digital pressure gauges, pressure transducers with digital output of the measured quantity) | Calibration – pressure Gas; Absolute pressure — 0 kPa to 7 MPa · CMC 0,05 % + 100 Pa Gas; Overpressure — -100 kPa to -1 kPa · CMC 130 Pa Gas; Overpressure — -1 kPa to 1 kPa · CMC 3,2 Pa Gas; Overpressure — 1 kPa to 35 kPa · CMC 18 Pa Gas; Overpressure — 35 kPa to 7 MPa · CMC 0,05 % Liquids; Absolute pressure — 0 kPa to 7 MPa · CMC 0,05 % + 100 Pa Liquids; Absolute pressure — 7 MPa to 70 MPa · CMC 0,05 % Liquids; Absolute pressure — 70 MPa to 140 MPa · CMC 0,2 % Liquids; Overpressure — 0 MPa to 1,4 MPa · CMC 1,4 kPa Liquids; Overpressure — 1,4 MPa to 70 MPa · CMC 0,05 % Liquids; Overpressure — 70 MPa to 140 MPa · CMC 0,2 % CMC for the field of measured quantity: Pressure |
Comparative measurement by a reference digital pressure gauge | KP T1, KP T2 | |
| 58 | Direct-indicating thermometers | Calibration – temperature -50 °C to 0 °C · CMC 0,14 °C 100 °C to 200 °C · CMC 0,22 °C 200 °C to 300 °C · CMC 0,32 °C 300 °C to 400 °C · CMC 0,42 °C 400 °C to 500 °C · CMC 0,52 °C 500 °C to 650 °C · CMC 0,67 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference digital thermometer in a dry block calibrator | KP TE1 | |
| 59 | Direct-indicating thermometers | Calibration – temperature 0 °C to 100 °C · CMC 0,08 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference digital thermometer in a liquid bath | KP TE1 | |
| 60 | Direct-indicating thermometers | Calibration – temperature 650 °C to 1100 °C · CMC 1,5 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference digital thermometer in an air oven | KP TE1 | |
| 61 | Contactless thermometers | Calibration – temperature -10 °C to 200 °C · CMC 3,0 °C 200 °C to 500 °C · CMC 6,0 °C 500 °C to 800 °C · CMC 10,0 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference pyrometer on target-type or cavity-type black body | KP TE4 | |
| 62 | Thermoelectric temperature sensors | Calibration – temperature -50 °C to 0 °C · CMC 0,7 °C 100 °C to 550 °C · CMC 0,9 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference digital thermometer in a dry block calibrator | KP TE2 | |
| 63 | Thermoelectric temperature sensors | Calibration – temperature 0 °C to 100 °C · CMC 0,7 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference digital thermometer in a liquid bath | KP TE2 | |
| 64 | Thermoelectric temperature sensors | Calibration – temperature 550 °C to 800 °C · CMC 2,3 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference digital thermometer in an air oven | KP TE2 | |
| 65 | Resistance temperature sensors | Calibration – temperature -50 °C to 0 °C · CMC 0,15 °C 100 °C to 400 °C · CMC 0,45 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference digital thermometer in a dry block calibrator | KP TE3 | |
| 66 | Resistance temperature sensors | Calibration – temperature 0 °C to 100 °C · CMC 0,13 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference digital thermometer in a liquid bath | KP TE3 | |
| 67 | DC voltage / DC voltage sources | Calibration – electrical quantities 0 mV to 100 mV · CMC 0,0062 % + 6,1 µV 0,1 V to 1 V · CMC 0,0047 % + 16 µV 1 V to 10 V · CMC 0,0047 % + 0,14 mV 10 V to 100 V · CMC 0,0079 % + 2,0 mV 100 V to 1000 V · CMC 0,0079 % + 20 mV CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a standard multimeter | KP EL2 | |
| 68 | DC voltage / DC voltage meters | Calibration – electrical quantities 0 mV to 200 mV · CMC 0,0053 % + 7,7 µV 0,2 V to 2 V · CMC 0,0028 % + 15 µV 2 V to 20 V · CMC 0,0028 % + 0,15 mV 20 V to 200 V · CMC 0,0028 % + 1,5 mV 200 V to 1000 V · CMC 0,0035 % + 17 mV CMC for the field of measured quantity: Electrical quantities |
Direct generation with a standard calibrator | KP EL1 | |
| 69 | Direct current / Direct current sources | Calibration – electrical quantities 0 µA to 10 µA · CMC 0,050 % + 6,1 nA 10 µA to 100 µA · CMC 0,074 % + 17 nA 0,1 mA to 1 mA · CMC 0,075 % + 0,16 µA 1 mA to 10 mA · CMC 0,034 % + 1,2 µA 10 mA to 100 mA · CMC 0,034 % + 12 µA 100 mA to 1 A · CMC 0,068 % + 0,15 mA 1 A to 3 A · CMC 0,061 % + 1,1 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a standard multimeter | KP EL2 | |
| 70 | Direct current / Direct current meters | Calibration – electrical quantities 0 µA to 200 µA · CMC 0,020 % + 73 nA 0,2 mA to 2 mA · CMC 0,016 % + 0,13 µA 2 mA to 20 mA · CMC 0,009 % + 0,94 µA 20 mA to 200 mA · CMC 0,012 % + 9,7 µA 0,2 A to 2 A · CMC 0,018 % + 0,13 mA 2 A to 30 A · CMC 0,069 % + 2,5 mA CMC for the field of measured quantity: Electrical quantities |
Direct generation with a standard calibrator | KP EL1 | |
| 71 | Direct current / Direct current meters | Calibration – electrical quantities 30 A to 1500 A · CMC 0,42 % + 0,13 A CMC for the field of measured quantity: Electrical quantities |
Simulation using current coil | KP EL1 | |
| 72 | AC voltage / AC voltage sources | Calibration – electrical quantities 10 Hz to 20 kHz — 0,1 mV to 100 mV · CMC 0,086 % + 36 µV 20 kHz to 50 kHz — 0,1 mV to 100 mV · CMC 0,16 % + 59 µV 50 kHz to 100 kHz — 0,1 mV to 100 mV · CMC 0,69 % + 93 µV 10 Hz to 20 kHz — 0,1 V to 1 V · CMC 0,076 % + 0,43 mV 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 0,14 % + 0,73 mV 50 kHz to 100 kHz — 0,1 V to 1 V · CMC 0,71 % + 0,81 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 0,076 % + 4,4 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 0,14 % + 7,3 mV 50 kHz to 100 kHz — 1 V to 10 V · CMC 0,71 % + 17 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 0,076 % + 44 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 0,14 % + 73 mV 50 kHz to 100 kHz — 10 V to 100 V · CMC 0,71 % + 81 mV 10 Hz to 20 kHz — 100 V to 750 V · CMC 0,07 % + 0,35 V 20 kHz to 50 kHz — 100 V to 750 V · CMC 0,14 % + 0,59 V 50 kHz to 100 kHz — 100 V to 750 V · CMC 0,61 % + 1,5 V CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a standard multimeter | KP EL2 | |
| 73 | AC voltage / AC voltage meters | Calibration – electrical quantities 10 Hz to 45 Hz — 0,1 mV to 200 mV · CMC 0,16 % + 64 µV 45 Hz to 10 kHz — 0,1 mV to 200 mV · CMC 0,049 % + 69 µV 10 kHz to 20 kHz — 0,1 mV to 200 mV · CMC 0,12 % + 86 µV 20 kHz to 50 kHz — 0,1 mV to 200 mV · CMC 0,20 % + 98 µV 10 Hz to 45 Hz — 0,2 V to 2 V · CMC 0,082 % + 0,38 mV 45 Hz to 10 kHz — 0,2 V to 2 V · CMC 0,042 % + 0,29 mV 10 kHz to 20 kHz — 0,2 V to 2 V · CMC 0,12 % + 0,46 mV 20 kHz to 50 kHz — 0,2 V to 2 V · CMC 0,17 % + 0,73 mV 10 Hz to 45 Hz — 2 V to 20 V · CMC 0,084 % + 3,8 mV 45 Hz to 10 kHz — 2 V to 20 V · CMC 0,042 % + 2,7 mV 10 kHz to 20 kHz — 2 V to 20 V · CMC 0,12 % + 4,7 mV 20 kHz to 50 kHz — 2 V to 20 V · CMC 0,17 % + 5,6 mV 30 Hz to 45 Hz — 20 V to 200 V · CMC 0,082 % + 31 mV 45 Hz to 10 kHz — 20 V to 200 V · CMC 0,10 % + 43 mV 10 kHz to 20 kHz — 20 V to 200 V · CMC 0,14 % + 56 mV 20 kHz to 40 kHz — 20 V to 200 V · CMC 0,17 % + 61 mV 30 Hz to 45 Hz — 200 V to 1000 V · CMC 0,082 % + 0,45 V 45 Hz to 1 kHz — 200 V to 1000 V · CMC 0,09 % + 0,28 V 1 kHz to 5 kHz — 200 V to 1000 V · CMC 0,14 % + 0,38 V 5 kHz to 10 kHz — 200 V to 1000 V · CMC 0,16 % + 0,49 V CMC for the field of measured quantity: Electrical quantities |
Direct generation with a standard calibrator | KP EL1 | |
| 74 | Alternating current / Alternating current sources | Calibration – electrical quantities 10 Hz to 1 kHz — 0,1 µA to 100 µA · CMC 0,15 % + 7,3 nA 10 Hz to 5 kHz — 0,1 mA to 1 mA · CMC 0,10 % + 0,51 µA 10 Hz to 5 kHz — 1 mA to 10 mA · CMC 0,10 % + 5,1 µA 10 Hz to 5 kHz — 10 mA to 100 mA · CMC 0,10 % + 51 µA 10 Hz to 5 kHz — 0,1 A to 1 A · CMC 0,10 % + 0,51 mA 10 Hz to 5 kHz — 1 A to 3 A · CMC 0,15 % + 3,4 mA CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a standard multimeter | KP EL2 | |
| 75 | Alternating current / Alternating current meters | Calibration – electrical quantities 10 Hz to 45 Hz — 20 µA to 200 µA · CMC 0,25 % + 0,40 µA 45 Hz to 1 kHz — 20 µA to 200 µA · CMC 0,08 % + 0,30 µA 10 Hz to 45 Hz — 0,2 mA to 2 mA · CMC 0,23 % + 0,40 µA 45 Hz to 1 kHz — 0,2 mA to 2 mA · CMC 0,06 % + 0,30 µA 10 Hz to 45 Hz — 2 mA to 20 mA · CMC 0,23 % + 4,5 µA 45 Hz to 1 kHz — 2 mA to 20 mA · CMC 0,05 % + 3,0 µA 10 Hz to 45 Hz — 20 mA to 200 mA · CMC 0,23 % + 45 µA 45 Hz to 1 kHz — 20 mA to 200 mA · CMC 0,05 % + 30 µA 10 Hz to 45 Hz — 0,2 A to 2 A · CMC 0,23 % + 0,45 mA 45 Hz to 1 kHz — 0,2 A to 2 A · CMC 0,06 % + 0,30 mA 30 Hz to 45 Hz — 2 A to 30 A · CMC 0,23 % + 4,5 mA 45 Hz to 100 Hz — 2 A to 30 A · CMC 0,06 % + 3,0 mA 100 Hz to 1 kHz — 2 A to 30 A · CMC 0,60 % + 5,8 mA CMC for the field of measured quantity: Electrical quantities |
Direct generation with a standard calibrator | KP EL1 | |
| 76 | Alternating current / Alternating current meters | Calibration – electrical quantities 30 Hz to 60 Hz — 30 A to 1500 A · CMC 0,42 % + 0,13 A CMC for the field of measured quantity: Electrical quantities |
Simulation using current coil | KP EL1 | |
| 77 | DC resistance / DC resistance meters | Calibration – electrical quantities 0,1 Ω · CMC 8,7 mΩ 1 Ω · CMC 8,9 mΩ 10 Ω · CMC 11 mΩ 100 Ω · CMC 20 mΩ 1 kΩ · CMC 0,16 Ω 10 kΩ · CMC 1,6 Ω 100 kΩ · CMC 15 Ω 1 MΩ · CMC 0,29 kΩ 10 MΩ · CMC 8,0 kΩ 100 MΩ · CMC 0,98 MΩ 1 GΩ · CMC 22 MΩ 0 Ω to 100 Ω · CMC 0,018 % + 88 mΩ 100 Ω to 330 Ω · CMC 0,012 % + 0,11 Ω 330 Ω to 1 kΩ · CMC 0,01 % + 0,19 Ω 1 kΩ to 3,3 kΩ · CMC 0,012 % + 0,29 Ω 3,3 kΩ to 10 kΩ · CMC 0,0082 % + 1,4 Ω 10 kΩ to 33 kΩ · CMC 0,012 % + 2,2 Ω 33 kΩ to 100 kΩ · CMC 0,0066 % + 18 Ω 100 kΩ to 330 kΩ · CMC 0,011 % + 24 Ω 330 kΩ to 1 MΩ · CMC 0,0066 % + 0,18 kΩ 1 MΩ to 3,3 MΩ · CMC 0,013 % + 0,24 kΩ 3,3 MΩ to 10 MΩ · CMC 0,0075 % + 1,8 kΩ 10 MΩ to 33 MΩ · CMC 0,052 % + 6,4 kΩ 33 MΩ to 100 MΩ · CMC 0,064 % + 0,21 MΩ 100 MΩ to 330 MΩ · CMC 1,3 % + 1,9 MΩ 330 MΩ to 1 GΩ · CMC 2,4 % + 13 MΩ CMC for the field of measured quantity: Electrical quantities |
Direct generation with a standard calibrator | KP EL 1 | |
| 78 | Capacitance / Electrical Capacitance Meters | Calibration – electrical quantities 1 kHz — 1 nF · CMC 0,48 % 1 kHz — 2 nF · CMC 0,73 % 1 kHz — 5 nF · CMC 0,70 % 1 kHz — 10 nF · CMC 0,54 % 1 kHz — 100 nF · CMC 0,41 % 1 kHz — 1 µF · CMC 0,65 % 1 kHz — 10 µF · CMC 0,98 % CMC for the field of measured quantity: Electrical quantities |
Direct generation with a standard calibrator | KP EL1 | |
| 79 | Capacitance / Electrical Capacitance Meters | Calibration – electrical quantities 10 µF to 100 µF · CMC 1,2 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard multimeter | KP EL1 | |
| 80 | Time interval / time meters, stopwatches, timers | Calibration – time quantities and frequency 1 s to 86400 s · CMC 0,5 s CMC for the field of measured quantity: Time quantities and frequency |
Comparison with a reference digital stopwatch | KP Č1 | |
| 81 | Frequency / low frequency and high frequency counters | Calibration – time quantities and frequency 1 Hz to 100 kHz · CMC 1,7.10⁻⁶ 100 kHz to 1000 kHz · CMC 2,3.10⁻⁶ 10 MHz · CMC 1,7.10⁻⁵ CMC for the field of measured quantity: Time quantities and frequency |
Direct generation by reference calibrator | KP EL1 | |
| 82 | Relative humidity meters except psychrometers | Calibration – humidity (20 to 40) °C — 10 % RH to 95 % RH · CMC 2,3 % RH CMC for the field of measured quantity: Humidity |
Comparative measurement by a reference hygrometer in a humidity generator | KP VL1 | |
Reference standards (42)
KP D1
KP D10
KP D11
KP D12
KP D13
KP D14
KP D15
KP D16
KP D17
KP D18
KP D19
KP D2
KP D20
KP D21
KP D3
KP D4
KP D5
KP D6
KP D7
KP D8
KP D9
KP DR1
KP EL 1
KP EL1
KP EL2
KP OT1
KP P1
KP R1
KP R2
KP S1
KP S2
KP T1
KP T2
KP TE1
KP TE2
KP TE3
KP TE4
KP TV1
KP VA1
KP VA2
KP VL1
KP Č1