{"lab":{"_id":"6ade8b31ff0682476170810e","accr_number":"2301","country":"CZ","accr_body":"ČIA","address":"Krumlovská 1454/26, 664 91 Ivančice","categories":["metrology"],"city":"Ivančice","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.370588,49.0973941]},"map_coord":[49.0973941,16.370588],"map_geo":"cai-mapa","methods_count":82,"name":"M & B Calibr, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów do pomiaru długości, kąta płaskiego, objętości, masy, prędkości obrotowej, twardości, chropowatości, siły, ciśnienia, temperatury, wielkości elektrycznych, wielkości czasu i wilgotności, w zakresie określonym w załączniku do świadectwa.","search_text":"m & b calibr, spol. s r.o. krumlovská 1454/26, 664 91 ivančice 2301","source_page_url":"https://www.cai.cz/?subjekt=2301-m-b-calibr-spol-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"02-07-2029","website":"www.mbcalibr.cz","certificate_date":"26.09.2025","certificate_no":"486/2025","certificate_replaces":"317/2024 z 02.07.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów do pomiaru długości, kąta płaskiego, objętości, masy, prędkości obrotowej, twardości, chropowatości, siły, ciśnienia, temperatury, wielkości elektrycznych, wielkości czasu i wilgotności, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of meters of length, plane angle, volume, mass, rotational speed, hardness, roughness, force, pressure, temperature, electrical quantities, time quantities and humidity to the extent as specified in the appendix to this Certificate.","zh":"长度、平面角、体积、质量、转速、硬度、粗糙度、力、压力、温度、电学量、时间量和湿度测量仪器的校准，范围见本证书附件。","cs":"Kalibrace měřidel délky, rovinného úhlu, objemu, hmotnosti, otáček, tvrdosti, drsnosti, síly, tlaku, teploty, elektrických veličin, veličin času a vlhkosti, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"SMS","pl":"współrzędnościowa maszyna pomiarowa (WMP)","en":"coordinate measuring machine (CMM)","zh":"坐标测量机","cs":"souřadnicový měřicí stroj"},{"abbr":"L","pl":"długość nominalna w metrach","en":"nominal length in metres","zh":"标称长度，单位米","cs":"jmenovitá délka v metrech"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"417188343b753e11564f633de8387fcbd76c65dfb8e3ac990fe6ae4c6932e3c7","source_pdf_url":"https://www.cai.cz/OA/pdf/486_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/486_2025_EN.pdf"},"methods":[{"_id":"9d753be5dd52ba3feca62fae","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Płytki wzorcowe","test_object_en":"Parallel gauge blocks","test_object_zh":"量块","test_object_cs":"Koncové měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,5 mm do 1000 mm","cmc":"(2.L + 0,2) µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 1000 mm","cmc":"(2.L + 0,2) µm"}],"parameters_zh":[{"name":"","range":"0,5 mm 至 1000 mm","cmc":"(2.L + 0,2) µm"}],"parameters_cs":[{"name":"","range":"0,5 mm až 1000 mm","cmc":"(2.L + 0,2) µm"}],"technique":"Pomiar porównawczy z płytkami wzorcowymi","technique_en":"Comparative measurement using parallel gauge blocks","technique_zh":"用量块比较测量","technique_cs":"Porovnávací měření s koncovými měrkami","techniques":["Pomiar porównawczy z płytkami wzorcowymi"],"techniques_en":["Comparative measurement using parallel gauge blocks"],"techniques_zh":["用量块比较测量"],"techniques_cs":["Porovnávací měření s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,5 mm do 1000 mm CMC (2.L + 0,2) µm\nPomiar porównawczy z płytkami wzorcowymi","reference":"KP D1","norm_bases":["KP D1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe Wzorcowanie – długość Pomiar porównawczy z płytkami wzorcowymi od 0,5 mm do 1000 mm CMC (2.L + 0,2) µm Koncové měrky Kalibrace – délka Porovnávací měření s koncovými měrkami 0,5 mm až 1000 mm CMC (2.L + 0,2) µm KP D1 Plytki wzorcowe Wzorcowanie – dlugosc Pomiar porownawczy z plytkami wzorcowymi od 0,5 mm do 1000 mm CMC (2.L + 0,2) µm Koncove merky Kalibrace – delka Porovnavaci mereni s koncovymi merkami 0,5 mm az 1000 mm CMC (2.L + 0,2) µm KP D1","search_en":"Parallel gauge blocks Calibration – length Comparative measurement using parallel gauge blocks 0,5 mm to 1000 mm CMC (2.L + 0,2) µm KP D1","search_zh":"量块 校准 – 长度 用量块比较测量 0,5 mm 至 1000 mm CMC (2.L + 0,2) µm KP D1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"552ad3f3ac6c3f4a252cb635","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Stalowe przymiary kreskowe","test_object_en":"Steel length gauges","test_object_zh":"钢直尺","test_object_cs":"Ocelová délková měřítka","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 2 m","cmc":"60 µm"},{"name":"","range":"od 2 m do 5 m","cmc":"180 µm"}],"parameters_en":[{"name":"","range":"0 m to 2 m","cmc":"60 µm"},{"name":"","range":"2 m to 5 m","cmc":"180 µm"}],"parameters_zh":[{"name":"","range":"0 m 至 2 m","cmc":"60 µm"},{"name":"","range":"2 m 至 5 m","cmc":"180 µm"}],"parameters_cs":[{"name":"","range":"0 m až 2 m","cmc":"60 µm"},{"name":"","range":"2 m až 5 m","cmc":"180 µm"}],"technique":"Pomiar porównawczy z płytkami wzorcowymi","technique_en":"Comparative measurement using parallel gauge blocks","technique_zh":"用量块比较测量","technique_cs":"Porovnávací měření s koncovými měrkami","techniques":["Pomiar porównawczy z płytkami wzorcowymi"],"techniques_en":["Comparative measurement using parallel gauge blocks"],"techniques_zh":["用量块比较测量"],"techniques_cs":["Porovnávací měření s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 m do 2 m CMC 60 µm\nod 2 m do 5 m CMC 180 µm\nPomiar porównawczy z płytkami wzorcowymi","reference":"KP D2","norm_bases":["KP D2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stalowe przymiary kreskowe Wzorcowanie – długość Pomiar porównawczy z płytkami wzorcowymi od 0 m do 2 m CMC 60 µm od 2 m do 5 m CMC 180 µm Ocelová délková měřítka Kalibrace – délka Porovnávací měření s koncovými měrkami 0 m až 2 m CMC 60 µm 2 m až 5 m CMC 180 µm KP D2 Stalowe przymiary kreskowe Wzorcowanie – dlugosc Pomiar porownawczy z plytkami wzorcowymi od 0 m do 2 m CMC 60 µm od 2 m do 5 m CMC 180 µm Ocelova delkova meritka Kalibrace – delka Porovnavaci mereni s koncovymi merkami 0 m az 2 m CMC 60 µm 2 m az 5 m CMC 180 µm KP D2","search_en":"Steel length gauges Calibration – length Comparative measurement using parallel gauge blocks 0 m to 2 m CMC 60 µm 2 m to 5 m CMC 180 µm KP D2","search_zh":"钢直尺 校准 – 长度 用量块比较测量 0 m 至 2 m CMC 60 µm 2 m 至 5 m CMC 180 µm KP D2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"faae65d64c4ebd6e8c8fd18c","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Stalowe taśmy miernicze zwijane","test_object_en":"Steel tape measures","test_object_zh":"钢卷尺","test_object_cs":"Ocelové svinovací metry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 2 m","cmc":"0,14 mm"},{"name":"","range":"od 2 m do 3 m","cmc":"0,28 mm"},{"name":"","range":"od 3 m do 5 m","cmc":"0,42 mm"},{"name":"","range":"od 5 m do 8 m","cmc":"0,70 mm"},{"name":"","range":"od 8 m do 10 m","cmc":"0,98 mm"}],"parameters_en":[{"name":"","range":"0 m to 2 m","cmc":"0,14 mm"},{"name":"","range":"2 m to 3 m","cmc":"0,28 mm"},{"name":"","range":"3 m to 5 m","cmc":"0,42 mm"},{"name":"","range":"5 m to 8 m","cmc":"0,70 mm"},{"name":"","range":"8 m to 10 m","cmc":"0,98 mm"}],"parameters_zh":[{"name":"","range":"0 m 至 2 m","cmc":"0,14 mm"},{"name":"","range":"2 m 至 3 m","cmc":"0,28 mm"},{"name":"","range":"3 m 至 5 m","cmc":"0,42 mm"},{"name":"","range":"5 m 至 8 m","cmc":"0,70 mm"},{"name":"","range":"8 m 至 10 m","cmc":"0,98 mm"}],"parameters_cs":[{"name":"","range":"0 m až 2 m","cmc":"0,14 mm"},{"name":"","range":"2 m až 3 m","cmc":"0,28 mm"},{"name":"","range":"3 m až 5 m","cmc":"0,42 mm"},{"name":"","range":"5 m až 8 m","cmc":"0,70 mm"},{"name":"","range":"8 m až 10 m","cmc":"0,98 mm"}],"technique":"Pomiar porównawczy na torze wzorcowym","technique_en":"Comparative measurement on a reference track","technique_zh":"在标准测量轨道上比较测量","technique_cs":"Porovnávací měření na etalonové trati","techniques":["Pomiar porównawczy na torze wzorcowym"],"techniques_en":["Comparative measurement on a reference track"],"techniques_zh":["在标准测量轨道上比较测量"],"techniques_cs":["Porovnávací měření na etalonové trati"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 m do 2 m CMC 0,14 mm\nod 2 m do 3 m CMC 0,28 mm\nod 3 m do 5 m CMC 0,42 mm\nod 5 m do 8 m CMC 0,70 mm\nod 8 m do 10 m CMC 0,98 mm\nPomiar porównawczy na torze wzorcowym","reference":"KP D2","norm_bases":["KP D2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stalowe taśmy miernicze zwijane Wzorcowanie – długość Pomiar porównawczy na torze wzorcowym od 0 m do 2 m CMC 0,14 mm od 2 m do 3 m CMC 0,28 mm od 3 m do 5 m CMC 0,42 mm od 5 m do 8 m CMC 0,70 mm od 8 m do 10 m CMC 0,98 mm Ocelové svinovací metry Kalibrace – délka Porovnávací měření na etalonové trati 0 m až 2 m CMC 0,14 mm 2 m až 3 m CMC 0,28 mm 3 m až 5 m CMC 0,42 mm 5 m až 8 m CMC 0,70 mm 8 m až 10 m CMC 0,98 mm KP D2 Stalowe tasmy miernicze zwijane Wzorcowanie – dlugosc Pomiar porownawczy na torze wzorcowym od 0 m do 2 m CMC 0,14 mm od 2 m do 3 m CMC 0,28 mm od 3 m do 5 m CMC 0,42 mm od 5 m do 8 m CMC 0,70 mm od 8 m do 10 m CMC 0,98 mm Ocelove svinovaci metry Kalibrace – delka Porovnavaci mereni na etalonove trati 0 m az 2 m CMC 0,14 mm 2 m az 3 m CMC 0,28 mm 3 m az 5 m CMC 0,42 mm 5 m az 8 m CMC 0,70 mm 8 m az 10 m CMC 0,98 mm KP D2","search_en":"Steel tape measures Calibration – length Comparative measurement on a reference track 0 m to 2 m CMC 0,14 mm 2 m to 3 m CMC 0,28 mm 3 m to 5 m CMC 0,42 mm 5 m to 8 m CMC 0,70 mm 8 m to 10 m CMC 0,98 mm KP D2","search_zh":"钢卷尺 校准 – 长度 在标准测量轨道上比较测量 0 m 至 2 m CMC 0,14 mm 2 m 至 3 m CMC 0,28 mm 3 m 至 5 m CMC 0,42 mm 5 m 至 8 m CMC 0,70 mm 8 m 至 10 m CMC 0,98 mm KP D2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dead3cb24c4a22a2a96cfea9","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"3","test_object":"Taśmy miernicze","test_object_en":"Tape measures","test_object_zh":"测量卷尺","test_object_cs":"Měřicí pásma","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 10 m","cmc":"0,4 mm"},{"name":"","range":"od 10 m do 20 m","cmc":"0,6 mm"},{"name":"","range":"od 20 m do 50 m","cmc":"1,0 mm"},{"name":"","range":"od 50 m do 100 m","cmc":"2,2 mm"}],"parameters_en":[{"name":"","range":"0 m to 10 m","cmc":"0,4 mm"},{"name":"","range":"10 m to 20 m","cmc":"0,6 mm"},{"name":"","range":"20 m to 50 m","cmc":"1,0 mm"},{"name":"","range":"50 m to 100 m","cmc":"2,2 mm"}],"parameters_zh":[{"name":"","range":"0 m 至 10 m","cmc":"0,4 mm"},{"name":"","range":"10 m 至 20 m","cmc":"0,6 mm"},{"name":"","range":"20 m 至 50 m","cmc":"1,0 mm"},{"name":"","range":"50 m 至 100 m","cmc":"2,2 mm"}],"parameters_cs":[{"name":"","range":"0 m až 10 m","cmc":"0,4 mm"},{"name":"","range":"10 m až 20 m","cmc":"0,6 mm"},{"name":"","range":"20 m až 50 m","cmc":"1,0 mm"},{"name":"","range":"50 m až 100 m","cmc":"2,2 mm"}],"technique":"Pomiar porównawczy na torze wzorcowym","technique_en":"Comparative measurement on a reference track","technique_zh":"在标准测量轨道上比较测量","technique_cs":"Porovnávací měření na etalonové trati","techniques":["Pomiar porównawczy na torze wzorcowym"],"techniques_en":["Comparative measurement on a reference track"],"techniques_zh":["在标准测量轨道上比较测量"],"techniques_cs":["Porovnávací měření na etalonové trati"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 m do 10 m CMC 0,4 mm\nod 10 m do 20 m CMC 0,6 mm\nod 20 m do 50 m CMC 1,0 mm\nod 50 m do 100 m CMC 2,2 mm\nPomiar porównawczy na torze wzorcowym","reference":"KP D3","norm_bases":["KP D3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Taśmy miernicze Wzorcowanie – długość Pomiar porównawczy na torze wzorcowym od 0 m do 10 m CMC 0,4 mm od 10 m do 20 m CMC 0,6 mm od 20 m do 50 m CMC 1,0 mm od 50 m do 100 m CMC 2,2 mm Měřicí pásma Kalibrace – délka Porovnávací měření na etalonové trati 0 m až 10 m CMC 0,4 mm 10 m až 20 m CMC 0,6 mm 20 m až 50 m CMC 1,0 mm 50 m až 100 m CMC 2,2 mm KP D3 Tasmy miernicze Wzorcowanie – dlugosc Pomiar porownawczy na torze wzorcowym od 0 m do 10 m CMC 0,4 mm od 10 m do 20 m CMC 0,6 mm od 20 m do 50 m CMC 1,0 mm od 50 m do 100 m CMC 2,2 mm Merici pasma Kalibrace – delka Porovnavaci mereni na etalonove trati 0 m az 10 m CMC 0,4 mm 10 m az 20 m CMC 0,6 mm 20 m az 50 m CMC 1,0 mm 50 m az 100 m CMC 2,2 mm KP D3","search_en":"Tape measures Calibration – length Comparative measurement on a reference track 0 m to 10 m CMC 0,4 mm 10 m to 20 m CMC 0,6 mm 20 m to 50 m CMC 1,0 mm 50 m to 100 m CMC 2,2 mm KP D3","search_zh":"测量卷尺 校准 – 长度 在标准测量轨道上比较测量 0 m 至 10 m CMC 0,4 mm 10 m 至 20 m CMC 0,6 mm 20 m 至 50 m CMC 1,0 mm 50 m 至 100 m CMC 2,2 mm KP D3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"91cdaf1460c2e46fbc0c7746","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"3","test_object":"Dalmierze laserowe","test_object_en":"Laser distance meters","test_object_zh":"激光测距仪","test_object_cs":"Laserové dálkoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 5 m","cmc":"0,2 mm"},{"name":"","range":"od 5 m do 10 m","cmc":"0,4 mm"}],"parameters_en":[{"name":"","range":"0 m to 5 m","cmc":"0,2 mm"},{"name":"","range":"5 m to 10 m","cmc":"0,4 mm"}],"parameters_zh":[{"name":"","range":"0 m 至 5 m","cmc":"0,2 mm"},{"name":"","range":"5 m 至 10 m","cmc":"0,4 mm"}],"parameters_cs":[{"name":"","range":"0 m až 5 m","cmc":"0,2 mm"},{"name":"","range":"5 m až 10 m","cmc":"0,4 mm"}],"technique":"Pomiar porównawczy na torze wzorcowym","technique_en":"Comparative measurement on a reference track","technique_zh":"在标准测量轨道上比较测量","technique_cs":"Porovnávací měření na etalonové trati","techniques":["Pomiar porównawczy na torze wzorcowym"],"techniques_en":["Comparative measurement on a reference track"],"techniques_zh":["在标准测量轨道上比较测量"],"techniques_cs":["Porovnávací měření na etalonové trati"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 m do 5 m CMC 0,2 mm\nod 5 m do 10 m CMC 0,4 mm\nPomiar porównawczy na torze wzorcowym","reference":"KP D3","norm_bases":["KP D3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Dalmierze laserowe Wzorcowanie – długość Pomiar porównawczy na torze wzorcowym od 0 m do 5 m CMC 0,2 mm od 5 m do 10 m CMC 0,4 mm Laserové dálkoměry Kalibrace – délka Porovnávací měření na etalonové trati 0 m až 5 m CMC 0,2 mm 5 m až 10 m CMC 0,4 mm KP D3 Dalmierze laserowe Wzorcowanie – dlugosc Pomiar porownawczy na torze wzorcowym od 0 m do 5 m CMC 0,2 mm od 5 m do 10 m CMC 0,4 mm Laserove dalkomery Kalibrace – delka Porovnavaci mereni na etalonove trati 0 m az 5 m CMC 0,2 mm 5 m az 10 m CMC 0,4 mm KP D3","search_en":"Laser distance meters Calibration – length Comparative measurement on a reference track 0 m to 5 m CMC 0,2 mm 5 m to 10 m CMC 0,4 mm KP D3","search_zh":"激光测距仪 校准 – 长度 在标准测量轨道上比较测量 0 m 至 5 m CMC 0,2 mm 5 m 至 10 m CMC 0,4 mm KP D3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0d60b0dc4f4974410ba802ce","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"3","test_object":"Kółka pomiarowe (drogomierze)","test_object_en":"Rolling length gauges","test_object_zh":"滚轮测距仪","test_object_cs":"Měřičky délek odvalovací","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 1000 m","cmc":"0,4 %"}],"parameters_en":[{"name":"","range":"0 m to 1000 m","cmc":"0,4 %"}],"parameters_zh":[{"name":"","range":"0 m 至 1000 m","cmc":"0,4 %"}],"parameters_cs":[{"name":"","range":"0 m až 1000 m","cmc":"0,4 %"}],"technique":"Pomiar porównawczy za pomocą taśmy mierniczej","technique_en":"Comparative measurement using a measuring tape","technique_zh":"借助测量卷尺比较测量","technique_cs":"Porovnávací měření pomocí měřičského pásma","techniques":["Pomiar porównawczy za pomocą taśmy mierniczej"],"techniques_en":["Comparative measurement using a measuring tape"],"techniques_zh":["借助测量卷尺比较测量"],"techniques_cs":["Porovnávací měření pomocí měřičského pásma"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 1000 m CMC 0,4 %\nPomiar porównawczy za pomocą taśmy mierniczej","reference":"KP D3","norm_bases":["KP D3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kółka pomiarowe (drogomierze) Wzorcowanie – długość Pomiar porównawczy za pomocą taśmy mierniczej od 0 m do 1000 m CMC 0,4 % Měřičky délek odvalovací Kalibrace – délka Porovnávací měření pomocí měřičského pásma 0 m až 1000 m CMC 0,4 % KP D3 Kolka pomiarowe (drogomierze) Wzorcowanie – dlugosc Pomiar porownawczy za pomoca tasmy mierniczej od 0 m do 1000 m CMC 0,4 % Mericky delek odvalovaci Kalibrace – delka Porovnavaci mereni pomoci mericskeho pasma 0 m az 1000 m CMC 0,4 % KP D3","search_en":"Rolling length gauges Calibration – length Comparative measurement using a measuring tape 0 m to 1000 m CMC 0,4 % KP D3","search_zh":"滚轮测距仪 校准 – 长度 借助测量卷尺比较测量 0 m 至 1000 m CMC 0,4 % KP D3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7838c49aa3f22e8166a779e7","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"4","test_object":"Pierścienie graniczne i nastawcze","test_object_en":"Limit and end measuring rings","test_object_zh":"极限环规和校对环规","test_object_cs":"Mezní a nástavné kroužky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 1 mm do 100 mm","cmc":"(2.L + 0,5) µm"},{"name":"","range":"od 100 mm do 500 mm","cmc":"(2.L + 2,4) µm"}],"parameters_en":[{"name":"","range":"1 mm to 100 mm","cmc":"(2.L + 0,5) µm"},{"name":"","range":"100 mm to 500 mm","cmc":"(2.L + 2,4) µm"}],"parameters_zh":[{"name":"","range":"1 mm 至 100 mm","cmc":"(2.L + 0,5) µm"},{"name":"","range":"100 mm 至 500 mm","cmc":"(2.L + 2,4) µm"}],"parameters_cs":[{"name":"","range":"1 mm až 100 mm","cmc":"(2.L + 0,5) µm"},{"name":"","range":"100 mm až 500 mm","cmc":"(2.L + 2,4) µm"}],"technique":"Pomiar bezpośredni i porównawczy na długościomierzu","technique_en":"Direct and comparative measurement by a distance meter","technique_zh":"在测长仪上直接和比较测量","technique_cs":"Přímé a porovnávací měření na délkoměru","techniques":["Pomiar bezpośredni i porównawczy na długościomierzu"],"techniques_en":["Direct and comparative measurement by a distance meter"],"techniques_zh":["在测长仪上直接和比较测量"],"techniques_cs":["Přímé a porovnávací měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 1 mm do 100 mm CMC (2.L + 0,5) µm\nod 100 mm do 500 mm CMC (2.L + 2,4) µm\nPomiar bezpośredni i porównawczy na długościomierzu","reference":"KP D4","norm_bases":["KP D4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pierścienie graniczne i nastawcze Wzorcowanie – długość Pomiar bezpośredni i porównawczy na długościomierzu od 1 mm do 100 mm CMC (2.L + 0,5) µm od 100 mm do 500 mm CMC (2.L + 2,4) µm Mezní a nástavné kroužky Kalibrace – délka Přímé a porovnávací měření na délkoměru 1 mm až 100 mm CMC (2.L + 0,5) µm 100 mm až 500 mm CMC (2.L + 2,4) µm KP D4 Pierscienie graniczne i nastawcze Wzorcowanie – dlugosc Pomiar bezposredni i porownawczy na dlugosciomierzu od 1 mm do 100 mm CMC (2.L + 0,5) µm od 100 mm do 500 mm CMC (2.L + 2,4) µm Mezni a nastavne krouzky Kalibrace – delka Prime a porovnavaci mereni na delkomeru 1 mm az 100 mm CMC (2.L + 0,5) µm 100 mm az 500 mm CMC (2.L + 2,4) µm KP D4","search_en":"Limit and end measuring rings Calibration – length Direct and comparative measurement by a distance meter 1 mm to 100 mm CMC (2.L + 0,5) µm 100 mm to 500 mm CMC (2.L + 2,4) µm KP D4","search_zh":"极限环规和校对环规 校准 – 长度 在测长仪上直接和比较测量 1 mm 至 100 mm CMC (2.L + 0,5) µm 100 mm 至 500 mm CMC (2.L + 2,4) µm KP D4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8e42b6924140022164f5702a","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"4","test_object":"Sprawdziany graniczne szczękowe","test_object_en":"Limit snap gauges","test_object_zh":"极限卡规","test_object_cs":"Mezní třmenové kalibry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 1 mm do 100 mm","cmc":"(2.L + 0,5) µm"},{"name":"","range":"od 100 mm do 500 mm","cmc":"(2.L + 2,4) µm"}],"parameters_en":[{"name":"","range":"1 mm to 100 mm","cmc":"(2.L + 0,5) µm"},{"name":"","range":"100 mm to 500 mm","cmc":"(2.L + 2,4) µm"}],"parameters_zh":[{"name":"","range":"1 mm 至 100 mm","cmc":"(2.L + 0,5) µm"},{"name":"","range":"100 mm 至 500 mm","cmc":"(2.L + 2,4) µm"}],"parameters_cs":[{"name":"","range":"1 mm až 100 mm","cmc":"(2.L + 0,5) µm"},{"name":"","range":"100 mm až 500 mm","cmc":"(2.L + 2,4) µm"}],"technique":"Pomiar bezpośredni i porównawczy na długościomierzu","technique_en":"Direct and comparative measurement by a distance meter","technique_zh":"在测长仪上直接和比较测量","technique_cs":"Přímé a porovnávací měření na délkoměru","techniques":["Pomiar bezpośredni i porównawczy na długościomierzu"],"techniques_en":["Direct and comparative measurement by a distance meter"],"techniques_zh":["在测长仪上直接和比较测量"],"techniques_cs":["Přímé a porovnávací měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 1 mm do 100 mm CMC (2.L + 0,5) µm\nod 100 mm do 500 mm CMC (2.L + 2,4) µm\nPomiar bezpośredni i porównawczy na długościomierzu","reference":"KP D4","norm_bases":["KP D4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany graniczne szczękowe Wzorcowanie – długość Pomiar bezpośredni i porównawczy na długościomierzu od 1 mm do 100 mm CMC (2.L + 0,5) µm od 100 mm do 500 mm CMC (2.L + 2,4) µm Mezní třmenové kalibry Kalibrace – délka Přímé a porovnávací měření na délkoměru 1 mm až 100 mm CMC (2.L + 0,5) µm 100 mm až 500 mm CMC (2.L + 2,4) µm KP D4 Sprawdziany graniczne szczekowe Wzorcowanie – dlugosc Pomiar bezposredni i porownawczy na dlugosciomierzu od 1 mm do 100 mm CMC (2.L + 0,5) µm od 100 mm do 500 mm CMC (2.L + 2,4) µm Mezni trmenove kalibry Kalibrace – delka Prime a porovnavaci mereni na delkomeru 1 mm az 100 mm CMC (2.L + 0,5) µm 100 mm az 500 mm CMC (2.L + 2,4) µm KP D4","search_en":"Limit snap gauges Calibration – length Direct and comparative measurement by a distance meter 1 mm to 100 mm CMC (2.L + 0,5) µm 100 mm to 500 mm CMC (2.L + 2,4) µm KP D4","search_zh":"极限卡规 校准 – 长度 在测长仪上直接和比较测量 1 mm 至 100 mm CMC (2.L + 0,5) µm 100 mm 至 500 mm CMC (2.L + 2,4) µm KP D4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5441bd0520e828ff2dd1f033","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"4","test_object":"Szczelinomierze listkowe","test_object_en":"Feeler gauges","test_object_zh":"塞尺","test_object_cs":"Lístkové spároměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,02 mm do 100 mm","cmc":"(2.L + 0,5) µm"}],"parameters_en":[{"name":"","range":"0,02 mm to 100 mm","cmc":"(2.L + 0,5) µm"}],"parameters_zh":[{"name":"","range":"0,02 mm 至 100 mm","cmc":"(2.L + 0,5) µm"}],"parameters_cs":[{"name":"","range":"0,02 mm až 100 mm","cmc":"(2.L + 0,5) µm"}],"technique":"Pomiar bezpośredni i porównawczy na długościomierzu","technique_en":"Direct and comparative measurement by a distance meter","technique_zh":"在测长仪上直接和比较测量","technique_cs":"Přímé a porovnávací měření na délkoměru","techniques":["Pomiar bezpośredni i porównawczy na długościomierzu"],"techniques_en":["Direct and comparative measurement by a distance meter"],"techniques_zh":["在测长仪上直接和比较测量"],"techniques_cs":["Přímé a porovnávací měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,02 mm do 100 mm CMC (2.L + 0,5) µm\nPomiar bezpośredni i porównawczy na długościomierzu","reference":"KP D4","norm_bases":["KP D4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Szczelinomierze listkowe Wzorcowanie – długość Pomiar bezpośredni i porównawczy na długościomierzu od 0,02 mm do 100 mm CMC (2.L + 0,5) µm Lístkové spároměry Kalibrace – délka Přímé a porovnávací měření na délkoměru 0,02 mm až 100 mm CMC (2.L + 0,5) µm KP D4 Szczelinomierze listkowe Wzorcowanie – dlugosc Pomiar bezposredni i porownawczy na dlugosciomierzu od 0,02 mm do 100 mm CMC (2.L + 0,5) µm Listkove sparomery Kalibrace – delka Prime a porovnavaci mereni na delkomeru 0,02 mm az 100 mm CMC (2.L + 0,5) µm KP D4","search_en":"Feeler gauges Calibration – length Direct and comparative measurement by a distance meter 0,02 mm to 100 mm CMC (2.L + 0,5) µm KP D4","search_zh":"塞尺 校准 – 长度 在测长仪上直接和比较测量 0,02 mm 至 100 mm CMC (2.L + 0,5) µm KP D4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc1758106df97aa6b7ff3c2e","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"4","test_object":"Sprawdziany graniczne walcowe","test_object_en":"Limit cylindrical gauges","test_object_zh":"极限圆柱塞规","test_object_cs":"Mezní válečkové kalibry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 100 mm do 500 mm","cmc":"(2.L + 2,4) µm"}],"parameters_en":[{"name":"","range":"100 mm to 500 mm","cmc":"(2.L + 2,4) µm"}],"parameters_zh":[{"name":"","range":"100 mm 至 500 mm","cmc":"(2.L + 2,4) µm"}],"parameters_cs":[{"name":"","range":"100 mm až 500 mm","cmc":"(2.L + 2,4) µm"}],"technique":"Pomiar bezpośredni i porównawczy na długościomierzu","technique_en":"Direct and comparative measurement by a distance meter","technique_zh":"在测长仪上直接和比较测量","technique_cs":"Přímé a porovnávací měření na délkoměru","techniques":["Pomiar bezpośredni i porównawczy na długościomierzu"],"techniques_en":["Direct and comparative measurement by a distance meter"],"techniques_zh":["在测长仪上直接和比较测量"],"techniques_cs":["Přímé a porovnávací měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 100 mm do 500 mm CMC (2.L + 2,4) µm\nPomiar bezpośredni i porównawczy na długościomierzu","reference":"KP D4","norm_bases":["KP D4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany graniczne walcowe Wzorcowanie – długość Pomiar bezpośredni i porównawczy na długościomierzu od 100 mm do 500 mm CMC (2.L + 2,4) µm Mezní válečkové kalibry Kalibrace – délka Přímé a porovnávací měření na délkoměru 100 mm až 500 mm CMC (2.L + 2,4) µm KP D4 Sprawdziany graniczne walcowe Wzorcowanie – dlugosc Pomiar bezposredni i porownawczy na dlugosciomierzu od 100 mm do 500 mm CMC (2.L + 2,4) µm Mezni valeckove kalibry Kalibrace – delka Prime a porovnavaci mereni na delkomeru 100 mm az 500 mm CMC (2.L + 2,4) µm KP D4","search_en":"Limit cylindrical gauges Calibration – length Direct and comparative measurement by a distance meter 100 mm to 500 mm CMC (2.L + 2,4) µm KP D4","search_zh":"极限圆柱塞规 校准 – 长度 在测长仪上直接和比较测量 100 mm 至 500 mm CMC (2.L + 2,4) µm KP D4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"357d5f94671add1dedd4bb92","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"5","test_object":"Szczelinomierze listkowe, sprawdziany graniczne walcowe","test_object_en":"Feeler gauges, Limit cylindrical gauges","test_object_zh":"塞尺、极限圆柱塞规","test_object_cs":"Lístkové spároměry Mezní válečkové kalibry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 1 mm do 125 mm","cmc":"(2.L + 2,4) µm"}],"parameters_en":[{"name":"","range":"1 mm to 125 mm","cmc":"(2.L + 2,4) µm"}],"parameters_zh":[{"name":"","range":"1 mm 至 125 mm","cmc":"(2.L + 2,4) µm"}],"parameters_cs":[{"name":"","range":"1 mm až 125 mm","cmc":"(2.L + 2,4) µm"}],"technique":"Pomiar bezpośredni na mikropasametrze","technique_en":"Direct measurement by a micropasameter","technique_zh":"用杠杆千分尺直接测量","technique_cs":"Přímé měření na mikropasametru","techniques":["Pomiar bezpośredni na mikropasametrze"],"techniques_en":["Direct measurement by a micropasameter"],"techniques_zh":["用杠杆千分尺直接测量"],"techniques_cs":["Přímé měření na mikropasametru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 1 mm do 125 mm CMC (2.L + 2,4) µm\nPomiar bezpośredni na mikropasametrze","reference":"KP D4","norm_bases":["KP D4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Szczelinomierze listkowe, sprawdziany graniczne walcowe Wzorcowanie – długość Pomiar bezpośredni na mikropasametrze od 1 mm do 125 mm CMC (2.L + 2,4) µm Lístkové spároměry Mezní válečkové kalibry Kalibrace – délka Přímé měření na mikropasametru 1 mm až 125 mm CMC (2.L + 2,4) µm KP D4 Szczelinomierze listkowe, sprawdziany graniczne walcowe Wzorcowanie – dlugosc Pomiar bezposredni na mikropasametrze od 1 mm do 125 mm CMC (2.L + 2,4) µm Listkove sparomery Mezni valeckove kalibry Kalibrace – delka Prime mereni na mikropasametru 1 mm az 125 mm CMC (2.L + 2,4) µm KP D4","search_en":"Feeler gauges, Limit cylindrical gauges Calibration – length Direct measurement by a micropasameter 1 mm to 125 mm CMC (2.L + 2,4) µm KP D4","search_zh":"塞尺、极限圆柱塞规 校准 – 长度 用杠杆千分尺直接测量 1 mm 至 125 mm CMC (2.L + 2,4) µm KP D4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a58237fa51a8f8d570336e3f","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"6","test_object":"Sprawdziany graniczne gwintowe trzpieniowe","test_object_en":"Limit plug gauges","test_object_zh":"螺纹极限塞规","test_object_cs":"Mezní závitové trny","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 1 mm do 200 mm","cmc":"(3.L + 3) µm"}],"parameters_en":[{"name":"","range":"1 mm to 200 mm","cmc":"(3.L + 3) µm"}],"parameters_zh":[{"name":"","range":"1 mm 至 200 mm","cmc":"(3.L + 3) µm"}],"parameters_cs":[{"name":"","range":"1 mm až 200 mm","cmc":"(3.L + 3) µm"}],"technique":"Pomiar bezpośredni na długościomierzu","technique_en":"Direct measurement by a distance meter","technique_zh":"在测长仪上直接测量","technique_cs":"Přímé měření na délkoměru","techniques":["Pomiar bezpośredni na długościomierzu"],"techniques_en":["Direct measurement by a distance meter"],"techniques_zh":["在测长仪上直接测量"],"techniques_cs":["Přímé měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 1 mm do 200 mm CMC (3.L + 3) µm\nPomiar bezpośredni na długościomierzu","reference":"KP D5","norm_bases":["KP D5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany graniczne gwintowe trzpieniowe Wzorcowanie – długość Pomiar bezpośredni na długościomierzu od 1 mm do 200 mm CMC (3.L + 3) µm Mezní závitové trny Kalibrace – délka Přímé měření na délkoměru 1 mm až 200 mm CMC (3.L + 3) µm KP D5 Sprawdziany graniczne gwintowe trzpieniowe Wzorcowanie – dlugosc Pomiar bezposredni na dlugosciomierzu od 1 mm do 200 mm CMC (3.L + 3) µm Mezni zavitove trny Kalibrace – delka Prime mereni na delkomeru 1 mm az 200 mm CMC (3.L + 3) µm KP D5","search_en":"Limit plug gauges Calibration – length Direct measurement by a distance meter 1 mm to 200 mm CMC (3.L + 3) µm KP D5","search_zh":"螺纹极限塞规 校准 – 长度 在测长仪上直接测量 1 mm 至 200 mm CMC (3.L + 3) µm KP D5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7f3f609f3427d7fdb420671e","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"6","test_object":"Sprawdziany graniczne gwintowe trzpieniowe","test_object_en":"Limit plug gauges","test_object_zh":"螺纹极限塞规","test_object_cs":"Mezní závitové trny","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 1 mm do 160 mm","cmc":"(1.L + 4) µm"}],"parameters_en":[{"name":"","range":"1 mm to 160 mm","cmc":"(1.L + 4) µm"}],"parameters_zh":[{"name":"","range":"1 mm 至 160 mm","cmc":"(1.L + 4) µm"}],"parameters_cs":[{"name":"","range":"1 mm až 160 mm","cmc":"(1.L + 4) µm"}],"technique":"Pomiar bezpośredni na urządzeniu MasterScanner XP 16060","technique_en":"Direct measurement on MasterScanner XP 16060","technique_zh":"在 MasterScanner XP 16060 设备上直接测量","technique_cs":"Přímé měření na zařízení MasterScanner XP 16060","techniques":["Pomiar bezpośredni na urządzeniu MasterScanner XP 16060"],"techniques_en":["Direct measurement on MasterScanner XP 16060"],"techniques_zh":["在 MasterScanner XP 16060 设备上直接测量"],"techniques_cs":["Přímé měření na zařízení MasterScanner XP 16060"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 1 mm do 160 mm CMC (1.L + 4) µm\nPomiar bezpośredni na urządzeniu MasterScanner XP 16060","reference":"KP D5","norm_bases":["KP D5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany graniczne gwintowe trzpieniowe Wzorcowanie – długość Pomiar bezpośredni na urządzeniu MasterScanner XP 16060 od 1 mm do 160 mm CMC (1.L + 4) µm Mezní závitové trny Kalibrace – délka Přímé měření na zařízení MasterScanner XP 16060 1 mm až 160 mm CMC (1.L + 4) µm KP D5 Sprawdziany graniczne gwintowe trzpieniowe Wzorcowanie – dlugosc Pomiar bezposredni na urzadzeniu MasterScanner XP 16060 od 1 mm do 160 mm CMC (1.L + 4) µm Mezni zavitove trny Kalibrace – delka Prime mereni na zarizeni MasterScanner XP 16060 1 mm az 160 mm CMC (1.L + 4) µm KP D5","search_en":"Limit plug gauges Calibration – length Direct measurement on MasterScanner XP 16060 1 mm to 160 mm CMC (1.L + 4) µm KP D5","search_zh":"螺纹极限塞规 校准 – 长度 在 MasterScanner XP 16060 设备上直接测量 1 mm 至 160 mm CMC (1.L + 4) µm KP D5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"16a62b155d7efbdd91d5b76f","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"6","test_object":"Sprawdziany pierścieniowe gwintowe","test_object_en":"Threaded rings","test_object_zh":"螺纹环规","test_object_cs":"Závitové kroužky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 1 mm do 3 mm","cmc":"(3.L + 3) µm"}],"parameters_en":[{"name":"","range":"1 mm to 3 mm","cmc":"(3.L + 3) µm"}],"parameters_zh":[{"name":"","range":"1 mm 至 3 mm","cmc":"(3.L + 3) µm"}],"parameters_cs":[{"name":"","range":"1 mm až 3 mm","cmc":"(3.L + 3) µm"}],"technique":"Porównanie z trzpieniem zużycia","technique_en":"Comparison by a wear pin gauge","technique_zh":"与磨损检验塞规比较","technique_cs":"Porovnání s trnem opotřebení","techniques":["Porównanie z trzpieniem zużycia"],"techniques_en":["Comparison by a wear pin gauge"],"techniques_zh":["与磨损检验塞规比较"],"techniques_cs":["Porovnání s trnem opotřebení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 1 mm do 3 mm CMC (3.L + 3) µm\nPorównanie z trzpieniem zużycia","reference":"KP D5","norm_bases":["KP D5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany pierścieniowe gwintowe Wzorcowanie – długość Porównanie z trzpieniem zużycia od 1 mm do 3 mm CMC (3.L + 3) µm Závitové kroužky Kalibrace – délka Porovnání s trnem opotřebení 1 mm až 3 mm CMC (3.L + 3) µm KP D5 Sprawdziany pierscieniowe gwintowe Wzorcowanie – dlugosc Porownanie z trzpieniem zuzycia od 1 mm do 3 mm CMC (3.L + 3) µm Zavitove krouzky Kalibrace – delka Porovnani s trnem opotrebeni 1 mm az 3 mm CMC (3.L + 3) µm KP D5","search_en":"Threaded rings Calibration – length Comparison by a wear pin gauge 1 mm to 3 mm CMC (3.L + 3) µm KP D5","search_zh":"螺纹环规 校准 – 长度 与磨损检验塞规比较 1 mm 至 3 mm CMC (3.L + 3) µm KP D5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"79c5e00f40eb3a14af0dc39a","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"6","test_object":"Sprawdziany pierścieniowe gwintowe","test_object_en":"Threaded rings","test_object_zh":"螺纹环规","test_object_cs":"Závitové kroužky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 2,5 mm do 200 mm","cmc":"(3.L + 3) µm"}],"parameters_en":[{"name":"","range":"2,5 mm to 200 mm","cmc":"(3.L + 3) µm"}],"parameters_zh":[{"name":"","range":"2,5 mm 至 200 mm","cmc":"(3.L + 3) µm"}],"parameters_cs":[{"name":"","range":"2,5 mm až 200 mm","cmc":"(3.L + 3) µm"}],"technique":"Pomiar pośredni na długościomierzu","technique_en":"Indirect measurement by a distance meter","technique_zh":"在测长仪上间接测量","technique_cs":"Nepřímé měření na délkoměru","techniques":["Pomiar pośredni na długościomierzu"],"techniques_en":["Indirect measurement by a distance meter"],"techniques_zh":["在测长仪上间接测量"],"techniques_cs":["Nepřímé měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 2,5 mm do 200 mm CMC (3.L + 3) µm\nPomiar pośredni na długościomierzu","reference":"KP D5","norm_bases":["KP D5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany pierścieniowe gwintowe Wzorcowanie – długość Pomiar pośredni na długościomierzu od 2,5 mm do 200 mm CMC (3.L + 3) µm Závitové kroužky Kalibrace – délka Nepřímé měření na délkoměru 2,5 mm až 200 mm CMC (3.L + 3) µm KP D5 Sprawdziany pierscieniowe gwintowe Wzorcowanie – dlugosc Pomiar posredni na dlugosciomierzu od 2,5 mm do 200 mm CMC (3.L + 3) µm Zavitove krouzky Kalibrace – delka Neprime mereni na delkomeru 2,5 mm az 200 mm CMC (3.L + 3) µm KP D5","search_en":"Threaded rings Calibration – length Indirect measurement by a distance meter 2,5 mm to 200 mm CMC (3.L + 3) µm KP D5","search_zh":"螺纹环规 校准 – 长度 在测长仪上间接测量 2,5 mm 至 200 mm CMC (3.L + 3) µm KP D5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"27e75595451679b6ed48a6ef","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"6","test_object":"Sprawdziany pierścieniowe gwintowe","test_object_en":"Threaded rings","test_object_zh":"螺纹环规","test_object_cs":"Závitové kroužky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 3 mm do 160 mm","cmc":"(1.L + 4) µm"}],"parameters_en":[{"name":"","range":"3 mm to 160 mm","cmc":"(1.L + 4) µm"}],"parameters_zh":[{"name":"","range":"3 mm 至 160 mm","cmc":"(1.L + 4) µm"}],"parameters_cs":[{"name":"","range":"3 mm až 160 mm","cmc":"(1.L + 4) µm"}],"technique":"Pomiar bezpośredni na urządzeniu MasterScanner XP 16060","technique_en":"Direct measurement on MasterScanner XP 16060","technique_zh":"在 MasterScanner XP 16060 设备上直接测量","technique_cs":"Přímé měření na zařízení MasterScanner XP 16060","techniques":["Pomiar bezpośredni na urządzeniu MasterScanner XP 16060"],"techniques_en":["Direct measurement on MasterScanner XP 16060"],"techniques_zh":["在 MasterScanner XP 16060 设备上直接测量"],"techniques_cs":["Přímé měření na zařízení MasterScanner XP 16060"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 3 mm do 160 mm CMC (1.L + 4) µm\nPomiar bezpośredni na urządzeniu MasterScanner XP 16060","reference":"KP D5","norm_bases":["KP D5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany pierścieniowe gwintowe Wzorcowanie – długość Pomiar bezpośredni na urządzeniu MasterScanner XP 16060 od 3 mm do 160 mm CMC (1.L + 4) µm Závitové kroužky Kalibrace – délka Přímé měření na zařízení MasterScanner XP 16060 3 mm až 160 mm CMC (1.L + 4) µm KP D5 Sprawdziany pierscieniowe gwintowe Wzorcowanie – dlugosc Pomiar bezposredni na urzadzeniu MasterScanner XP 16060 od 3 mm do 160 mm CMC (1.L + 4) µm Zavitove krouzky Kalibrace – delka Prime mereni na zarizeni MasterScanner XP 16060 3 mm az 160 mm CMC (1.L + 4) µm KP D5","search_en":"Threaded rings Calibration – length Direct measurement on MasterScanner XP 16060 3 mm to 160 mm CMC (1.L + 4) µm KP D5","search_zh":"螺纹环规 校准 – 长度 在 MasterScanner XP 16060 设备上直接测量 3 mm 至 160 mm CMC (1.L + 4) µm KP D5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"94c6e369f6c83153b344dd3d","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"7","test_object":"Sprawdziany graniczne gwintowe trzpieniowe","test_object_en":"Limit plug gauges","test_object_zh":"螺纹极限塞规","test_object_cs":"Mezní závitové trny","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 1 mm do 125 mm","cmc":"(3.L + 3,5) µm"}],"parameters_en":[{"name":"","range":"1 mm to 125 mm","cmc":"(3.L + 3,5) µm"}],"parameters_zh":[{"name":"","range":"1 mm 至 125 mm","cmc":"(3.L + 3,5) µm"}],"parameters_cs":[{"name":"","range":"1 mm až 125 mm","cmc":"(3.L + 3,5) µm"}],"technique":"Pomiar bezpośredni na mikropasametrze","technique_en":"Direct measurement by a micropasameter","technique_zh":"用杠杆千分尺直接测量","technique_cs":"Přímé měření na mikropasametru","techniques":["Pomiar bezpośredni na mikropasametrze"],"techniques_en":["Direct measurement by a micropasameter"],"techniques_zh":["用杠杆千分尺直接测量"],"techniques_cs":["Přímé měření na mikropasametru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 1 mm do 125 mm CMC (3.L + 3,5) µm\nPomiar bezpośredni na mikropasametrze","reference":"KP D5","norm_bases":["KP D5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany graniczne gwintowe trzpieniowe Wzorcowanie – długość Pomiar bezpośredni na mikropasametrze od 1 mm do 125 mm CMC (3.L + 3,5) µm Mezní závitové trny Kalibrace – délka Přímé měření na mikropasametru 1 mm až 125 mm CMC (3.L + 3,5) µm KP D5 Sprawdziany graniczne gwintowe trzpieniowe Wzorcowanie – dlugosc Pomiar bezposredni na mikropasametrze od 1 mm do 125 mm CMC (3.L + 3,5) µm Mezni zavitove trny Kalibrace – delka Prime mereni na mikropasametru 1 mm az 125 mm CMC (3.L + 3,5) µm KP D5","search_en":"Limit plug gauges Calibration – length Direct measurement by a micropasameter 1 mm to 125 mm CMC (3.L + 3,5) µm KP D5","search_zh":"螺纹极限塞规 校准 – 长度 用杠杆千分尺直接测量 1 mm 至 125 mm CMC (3.L + 3,5) µm KP D5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e32717f3c007c663d59273dc","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"8","test_object":"Przyrządy suwmiarkowe: suwmiarki, głębokościomierze, wysokościomierze","test_object_en":"Slide gauges: slide rules, depth gauges, height gauges","test_object_zh":"游标量具：卡尺、深度尺、高度尺","test_object_cs":"Posuvná měřidla: posuvky, hloubkoměry, výškoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"12 µm"},{"name":"","range":"od 1000 mm do 3000 mm","cmc":"20 µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"12 µm"},{"name":"","range":"1000 mm to 3000 mm","cmc":"20 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"12 µm"},{"name":"","range":"1000 mm 至 3000 mm","cmc":"20 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"12 µm"},{"name":"","range":"1000 mm až 3000 mm","cmc":"20 µm"}],"technique":"Pomiar porównawczy z płytkami wzorcowymi i pierścieniem","technique_en":"Comparative measurement using parallel gauge blocks and ring","technique_zh":"用量块和环规比较测量","technique_cs":"Porovnávací měření s koncovými měrkami a kroužkem","techniques":["Pomiar porównawczy z płytkami wzorcowymi i pierścieniem"],"techniques_en":["Comparative measurement using parallel gauge blocks and ring"],"techniques_zh":["用量块和环规比较测量"],"techniques_cs":["Porovnávací měření s koncovými měrkami a kroužkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 1000 mm CMC 12 µm\nod 1000 mm do 3000 mm CMC 20 µm\nPomiar porównawczy z płytkami wzorcowymi i pierścieniem","reference":"KP D6","norm_bases":["KP D6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy suwmiarkowe: suwmiarki, głębokościomierze, wysokościomierze Wzorcowanie – długość Pomiar porównawczy z płytkami wzorcowymi i pierścieniem od 0 mm do 1000 mm CMC 12 µm od 1000 mm do 3000 mm CMC 20 µm Posuvná měřidla: posuvky, hloubkoměry, výškoměry Kalibrace – délka Porovnávací měření s koncovými měrkami a kroužkem 0 mm až 1000 mm CMC 12 µm 1000 mm až 3000 mm CMC 20 µm KP D6 Przyrzady suwmiarkowe: suwmiarki, glebokosciomierze, wysokosciomierze Wzorcowanie – dlugosc Pomiar porownawczy z plytkami wzorcowymi i pierscieniem od 0 mm do 1000 mm CMC 12 µm od 1000 mm do 3000 mm CMC 20 µm Posuvna meridla: posuvky, hloubkomery, vyskomery Kalibrace – delka Porovnavaci mereni s koncovymi merkami a krouzkem 0 mm az 1000 mm CMC 12 µm 1000 mm az 3000 mm CMC 20 µm KP D6","search_en":"Slide gauges: slide rules, depth gauges, height gauges Calibration – length Comparative measurement using parallel gauge blocks and ring 0 mm to 1000 mm CMC 12 µm 1000 mm to 3000 mm CMC 20 µm KP D6","search_zh":"游标量具：卡尺、深度尺、高度尺 校准 – 长度 用量块和环规比较测量 0 mm 至 1000 mm CMC 12 µm 1000 mm 至 3000 mm CMC 20 µm KP D6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be2062dddfcc1e1cd257ac31","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"9","test_object":"Przyrządy mikrometryczne: mikrometry, pasametry, mikropasametry, głowice mikrometryczne, głębokościomierze mikrometryczne","test_object_en":"Micrometer gauges: micrometers, pasameters, micropasameters, micrometer heads, micrometer depth gauges","test_object_zh":"千分尺类量具：千分尺、杠杆卡规、杠杆千分尺、测微头、深度千分尺","test_object_cs":"Mikrometrická měřidla: mikrometry, pasametry, mikropasametry, mikrometrické hlavice, mikrometrické hloubkoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 25 mm","cmc":"0,7 µm"},{"name":"","range":"od 25 mm do 100 mm","cmc":"1,4 µm"},{"name":"","range":"od 100 mm do 1000 mm","cmc":"2,5 µm"},{"name":"","range":"od 1000 mm do 1500 mm","cmc":"4,1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"0,7 µm"},{"name":"","range":"25 mm to 100 mm","cmc":"1,4 µm"},{"name":"","range":"100 mm to 1000 mm","cmc":"2,5 µm"},{"name":"","range":"1000 mm to 1500 mm","cmc":"4,1 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"0,7 µm"},{"name":"","range":"25 mm 至 100 mm","cmc":"1,4 µm"},{"name":"","range":"100 mm 至 1000 mm","cmc":"2,5 µm"},{"name":"","range":"1000 mm 至 1500 mm","cmc":"4,1 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 25 mm","cmc":"0,7 µm"},{"name":"","range":"25 mm až 100 mm","cmc":"1,4 µm"},{"name":"","range":"100 mm až 1000 mm","cmc":"2,5 µm"},{"name":"","range":"1000 mm až 1500 mm","cmc":"4,1 µm"}],"technique":"Pomiar porównawczy z płytkami wzorcowymi","technique_en":"Comparative measurement using parallel gauge blocks","technique_zh":"用量块比较测量","technique_cs":"Porovnávací měření s koncovými měrkami","techniques":["Pomiar porównawczy z płytkami wzorcowymi"],"techniques_en":["Comparative measurement using parallel gauge blocks"],"techniques_zh":["用量块比较测量"],"techniques_cs":["Porovnávací měření s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 25 mm CMC 0,7 µm\nod 25 mm do 100 mm CMC 1,4 µm\nod 100 mm do 1000 mm CMC 2,5 µm\nod 1000 mm do 1500 mm CMC 4,1 µm\nPomiar porównawczy z płytkami wzorcowymi","reference":"KP D7","norm_bases":["KP D7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy mikrometryczne: mikrometry, pasametry, mikropasametry, głowice mikrometryczne, głębokościomierze mikrometryczne Wzorcowanie – długość Pomiar porównawczy z płytkami wzorcowymi od 0 mm do 25 mm CMC 0,7 µm od 25 mm do 100 mm CMC 1,4 µm od 100 mm do 1000 mm CMC 2,5 µm od 1000 mm do 1500 mm CMC 4,1 µm Mikrometrická měřidla: mikrometry, pasametry, mikropasametry, mikrometrické hlavice, mikrometrické hloubkoměry Kalibrace – délka Porovnávací měření s koncovými měrkami 0 mm až 25 mm CMC 0,7 µm 25 mm až 100 mm CMC 1,4 µm 100 mm až 1000 mm CMC 2,5 µm 1000 mm až 1500 mm CMC 4,1 µm KP D7 Przyrzady mikrometryczne: mikrometry, pasametry, mikropasametry, glowice mikrometryczne, glebokosciomierze mikrometryczne Wzorcowanie – dlugosc Pomiar porownawczy z plytkami wzorcowymi od 0 mm do 25 mm CMC 0,7 µm od 25 mm do 100 mm CMC 1,4 µm od 100 mm do 1000 mm CMC 2,5 µm od 1000 mm do 1500 mm CMC 4,1 µm Mikrometricka meridla: mikrometry, pasametry, mikropasametry, mikrometricke hlavice, mikrometricke hloubkomery Kalibrace – delka Porovnavaci mereni s koncovymi merkami 0 mm az 25 mm CMC 0,7 µm 25 mm az 100 mm CMC 1,4 µm 100 mm az 1000 mm CMC 2,5 µm 1000 mm az 1500 mm CMC 4,1 µm KP D7","search_en":"Micrometer gauges: micrometers, pasameters, micropasameters, micrometer heads, micrometer depth gauges Calibration – length Comparative measurement using parallel gauge blocks 0 mm to 25 mm CMC 0,7 µm 25 mm to 100 mm CMC 1,4 µm 100 mm to 1000 mm CMC 2,5 µm 1000 mm to 1500 mm CMC 4,1 µm KP D7","search_zh":"千分尺类量具：千分尺、杠杆卡规、杠杆千分尺、测微头、深度千分尺 校准 – 长度 用量块比较测量 0 mm 至 25 mm CMC 0,7 µm 25 mm 至 100 mm CMC 1,4 µm 100 mm 至 1000 mm CMC 2,5 µm 1000 mm 至 1500 mm CMC 4,1 µm KP D7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"49f5a2c2e2541222d5d347ff","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"10","test_object":"Mikrometry do otworów, średnicówki trójpunktowe","test_object_en":"Inside micrometers Three contact internal gauges","test_object_zh":"内径千分尺、三点式内径表","test_object_cs":"Dutinové mikrometry Třídotekové dutinoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 2 mm do 100 mm","cmc":"2,0 µm"},{"name":"","range":"od 100 mm do 300 mm","cmc":"4,0 µm"}],"parameters_en":[{"name":"","range":"2 mm to 100 mm","cmc":"2,0 µm"},{"name":"","range":"100 mm to 300 mm","cmc":"4,0 µm"}],"parameters_zh":[{"name":"","range":"2 mm 至 100 mm","cmc":"2,0 µm"},{"name":"","range":"100 mm 至 300 mm","cmc":"4,0 µm"}],"parameters_cs":[{"name":"","range":"2 mm až 100 mm","cmc":"2,0 µm"},{"name":"","range":"100 mm až 300 mm","cmc":"4,0 µm"}],"technique":"Pomiar porównawczy z pierścieniami nastawczymi","technique_en":"Comparative measurement using setting rings","technique_zh":"用校对环规比较测量","technique_cs":"Porovnávací měření s nastavovacími kroužky","techniques":["Pomiar porównawczy z pierścieniami nastawczymi"],"techniques_en":["Comparative measurement using setting rings"],"techniques_zh":["用校对环规比较测量"],"techniques_cs":["Porovnávací měření s nastavovacími kroužky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 2 mm do 100 mm CMC 2,0 µm\nod 100 mm do 300 mm CMC 4,0 µm\nPomiar porównawczy z pierścieniami nastawczymi","reference":"KP D8","norm_bases":["KP D8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mikrometry do otworów, średnicówki trójpunktowe Wzorcowanie – długość Pomiar porównawczy z pierścieniami nastawczymi od 2 mm do 100 mm CMC 2,0 µm od 100 mm do 300 mm CMC 4,0 µm Dutinové mikrometry Třídotekové dutinoměry Kalibrace – délka Porovnávací měření s nastavovacími kroužky 2 mm až 100 mm CMC 2,0 µm 100 mm až 300 mm CMC 4,0 µm KP D8 Mikrometry do otworow, srednicowki trojpunktowe Wzorcowanie – dlugosc Pomiar porownawczy z pierscieniami nastawczymi od 2 mm do 100 mm CMC 2,0 µm od 100 mm do 300 mm CMC 4,0 µm Dutinove mikrometry Tridotekove dutinomery Kalibrace – delka Porovnavaci mereni s nastavovacimi krouzky 2 mm az 100 mm CMC 2,0 µm 100 mm az 300 mm CMC 4,0 µm KP D8","search_en":"Inside micrometers Three contact internal gauges Calibration – length Comparative measurement using setting rings 2 mm to 100 mm CMC 2,0 µm 100 mm to 300 mm CMC 4,0 µm KP D8","search_zh":"内径千分尺、三点式内径表 校准 – 长度 用校对环规比较测量 2 mm 至 100 mm CMC 2,0 µm 100 mm 至 300 mm CMC 4,0 µm KP D8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ee926a59833dfdc6d278df85","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"11","test_object":"Średnicówki mikrometryczne prętowe","test_object_en":"Inside micrometer gauges","test_object_zh":"内径测微杆","test_object_cs":"Mikrometrické odpichy","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 10 mm do 3000 mm","cmc":"(3 L + 2,2) µm"}],"parameters_en":[{"name":"","range":"10 mm to 3000 mm","cmc":"(3 L + 2,2) µm"}],"parameters_zh":[{"name":"","range":"10 mm 至 3000 mm","cmc":"(3 L + 2,2) µm"}],"parameters_cs":[{"name":"","range":"10 mm až 3000 mm","cmc":"(3 L + 2,2) µm"}],"technique":"Pomiar bezpośredni na długościomierzu","technique_en":"Direct measurement by a distance meter","technique_zh":"在测长仪上直接测量","technique_cs":"Přímé měření na délkoměru","techniques":["Pomiar bezpośredni na długościomierzu"],"techniques_en":["Direct measurement by a distance meter"],"techniques_zh":["在测长仪上直接测量"],"techniques_cs":["Přímé měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 10 mm do 3000 mm CMC (3 L + 2,2) µm\nPomiar bezpośredni na długościomierzu","reference":"KP D9","norm_bases":["KP D9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Średnicówki mikrometryczne prętowe Wzorcowanie – długość Pomiar bezpośredni na długościomierzu od 10 mm do 3000 mm CMC (3 L + 2,2) µm Mikrometrické odpichy Kalibrace – délka Přímé měření na délkoměru 10 mm až 3000 mm CMC (3 L + 2,2) µm KP D9 Srednicowki mikrometryczne pretowe Wzorcowanie – dlugosc Pomiar bezposredni na dlugosciomierzu od 10 mm do 3000 mm CMC (3 L + 2,2) µm Mikrometricke odpichy Kalibrace – delka Prime mereni na delkomeru 10 mm az 3000 mm CMC (3 L + 2,2) µm KP D9","search_en":"Inside micrometer gauges Calibration – length Direct measurement by a distance meter 10 mm to 3000 mm CMC (3 L + 2,2) µm KP D9","search_zh":"内径测微杆 校准 – 长度 在测长仪上直接测量 10 mm 至 3000 mm CMC (3 L + 2,2) µm KP D9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"32dcade774ca705612c490c4","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"12","test_object":"Grubościomierze elektromagnetyczne, ultradźwiękowe","test_object_en":"Electromagnetic, ultrasonic thickness gauges","test_object_zh":"电磁式、超声波测厚仪","test_object_cs":"Tloušťkoměry elektromagnetické, ultrazvukové","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1,5 mm","cmc":"(1.L + 1,3) µm"},{"name":"","range":"od 1,5 mm do 500 mm","cmc":"(1.L + 2,3) µm"}],"parameters_en":[{"name":"","range":"0 mm to 1,5 mm","cmc":"(1.L + 1,3) µm"},{"name":"","range":"1,5 mm to 500 mm","cmc":"(1.L + 2,3) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1,5 mm","cmc":"(1.L + 1,3) µm"},{"name":"","range":"1,5 mm 至 500 mm","cmc":"(1.L + 2,3) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 1,5 mm","cmc":"(1.L + 1,3) µm"},{"name":"","range":"1,5 mm až 500 mm","cmc":"(1.L + 2,3) µm"}],"technique":"Pomiar porównawczy z wzorcem grubości","technique_en":"Comparative measurement by a thickness reference standard","technique_zh":"与厚度标准比较测量","technique_cs":"Porovnávací měření s etalonem tloušťky","techniques":["Pomiar porównawczy z wzorcem grubości"],"techniques_en":["Comparative measurement by a thickness reference standard"],"techniques_zh":["与厚度标准比较测量"],"techniques_cs":["Porovnávací měření s etalonem tloušťky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 1,5 mm CMC (1.L + 1,3) µm\nod 1,5 mm do 500 mm CMC (1.L + 2,3) µm\nPomiar porównawczy z wzorcem grubości","reference":"KP D10","norm_bases":["KP D10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grubościomierze elektromagnetyczne, ultradźwiękowe Wzorcowanie – długość Pomiar porównawczy z wzorcem grubości od 0 mm do 1,5 mm CMC (1.L + 1,3) µm od 1,5 mm do 500 mm CMC (1.L + 2,3) µm Tloušťkoměry elektromagnetické, ultrazvukové Kalibrace – délka Porovnávací měření s etalonem tloušťky 0 mm až 1,5 mm CMC (1.L + 1,3) µm 1,5 mm až 500 mm CMC (1.L + 2,3) µm KP D10 Grubosciomierze elektromagnetyczne, ultradzwiekowe Wzorcowanie – dlugosc Pomiar porownawczy z wzorcem grubosci od 0 mm do 1,5 mm CMC (1.L + 1,3) µm od 1,5 mm do 500 mm CMC (1.L + 2,3) µm Tloustkomery elektromagneticke, ultrazvukove Kalibrace – delka Porovnavaci mereni s etalonem tloustky 0 mm az 1,5 mm CMC (1.L + 1,3) µm 1,5 mm az 500 mm CMC (1.L + 2,3) µm KP D10","search_en":"Electromagnetic, ultrasonic thickness gauges Calibration – length Comparative measurement by a thickness reference standard 0 mm to 1,5 mm CMC (1.L + 1,3) µm 1,5 mm to 500 mm CMC (1.L + 2,3) µm KP D10","search_zh":"电磁式、超声波测厚仪 校准 – 长度 与厚度标准比较测量 0 mm 至 1,5 mm CMC (1.L + 1,3) µm 1,5 mm 至 500 mm CMC (1.L + 2,3) µm KP D10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8213e449b5c1cdfa43bdd26f","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"13","test_object":"Czujniki zegarowe zwykłe i dźwigniowe","test_object_en":"Direct and lever dial indicators","test_object_zh":"直接式和杠杆式百分表","test_object_cs":"Číselníkové úchylkoměry přímé a páčkové","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,3 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,3 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,3 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,3 µm"}],"technique":"Pomiar bezpośredni na specjalnym urządzeniu pomiarowym","technique_en":"Direct measurement by a special measuring device","technique_zh":"在专用测量装置上直接测量","technique_cs":"Přímé měření na speciálním měřícím zařízení","techniques":["Pomiar bezpośredni na specjalnym urządzeniu pomiarowym"],"techniques_en":["Direct measurement by a special measuring device"],"techniques_zh":["在专用测量装置上直接测量"],"techniques_cs":["Přímé měření na speciálním měřícím zařízení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC 0,3 µm\nPomiar bezpośredni na specjalnym urządzeniu pomiarowym","reference":"KP D11","norm_bases":["KP D11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki zegarowe zwykłe i dźwigniowe Wzorcowanie – długość Pomiar bezpośredni na specjalnym urządzeniu pomiarowym od 0 mm do 100 mm CMC 0,3 µm Číselníkové úchylkoměry přímé a páčkové Kalibrace – délka Přímé měření na speciálním měřícím zařízení 0 mm až 100 mm CMC 0,3 µm KP D11 Czujniki zegarowe zwykle i dzwigniowe Wzorcowanie – dlugosc Pomiar bezposredni na specjalnym urzadzeniu pomiarowym od 0 mm do 100 mm CMC 0,3 µm Ciselnikove uchylkomery prime a packove Kalibrace – delka Prime mereni na specialnim mericim zarizeni 0 mm az 100 mm CMC 0,3 µm KP D11","search_en":"Direct and lever dial indicators Calibration – length Direct measurement by a special measuring device 0 mm to 100 mm CMC 0,3 µm KP D11","search_zh":"直接式和杠杆式百分表 校准 – 长度 在专用测量装置上直接测量 0 mm 至 100 mm CMC 0,3 µm KP D11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c990f52108324e4bb131ec66","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"13","test_object":"Średnicówki dwupunktowe","test_object_en":"Two-contact internal gauges","test_object_zh":"两点式内径表","test_object_cs":"Dvoudotekové dutinoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 2 mm do 205 mm","cmc":"0,3 µm"}],"parameters_en":[{"name":"","range":"2 mm to 205 mm","cmc":"0,3 µm"}],"parameters_zh":[{"name":"","range":"2 mm 至 205 mm","cmc":"0,3 µm"}],"parameters_cs":[{"name":"","range":"2 mm až 205 mm","cmc":"0,3 µm"}],"technique":"Pomiar bezpośredni na specjalnym urządzeniu pomiarowym","technique_en":"Direct measurement by a special measuring device","technique_zh":"在专用测量装置上直接测量","technique_cs":"Přímé měření na speciálním měřícím zařízení","techniques":["Pomiar bezpośredni na specjalnym urządzeniu pomiarowym"],"techniques_en":["Direct measurement by a special measuring device"],"techniques_zh":["在专用测量装置上直接测量"],"techniques_cs":["Přímé měření na speciálním měřícím zařízení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 2 mm do 205 mm CMC 0,3 µm\nPomiar bezpośredni na specjalnym urządzeniu pomiarowym","reference":"KP D11","norm_bases":["KP D11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Średnicówki dwupunktowe Wzorcowanie – długość Pomiar bezpośredni na specjalnym urządzeniu pomiarowym od 2 mm do 205 mm CMC 0,3 µm Dvoudotekové dutinoměry Kalibrace – délka Přímé měření na speciálním měřícím zařízení 2 mm až 205 mm CMC 0,3 µm KP D11 Srednicowki dwupunktowe Wzorcowanie – dlugosc Pomiar bezposredni na specjalnym urzadzeniu pomiarowym od 2 mm do 205 mm CMC 0,3 µm Dvoudotekove dutinomery Kalibrace – delka Prime mereni na specialnim mericim zarizeni 2 mm az 205 mm CMC 0,3 µm KP D11","search_en":"Two-contact internal gauges Calibration – length Direct measurement by a special measuring device 2 mm to 205 mm CMC 0,3 µm KP D11","search_zh":"两点式内径表 校准 – 长度 在专用测量装置上直接测量 2 mm 至 205 mm CMC 0,3 µm KP D11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d02c21d10ea0422d78c1c885","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"14","test_object":"Sprawdziany, przyrządy pomiarowe, wzorniki, przyrządy do pomiaru płaskości i kąta","test_object_en":"Gauges, measuring jigs, templates, meters of plane and angle","test_object_zh":"量规、测量夹具、样板、平面和角度量具","test_object_cs":"Kalibry, měřicí přípravky, šablony, měřidla roviny a úhlu","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 2000 mm","cmc":"(4,5.L + 1,7) µm"}],"parameters_en":[{"name":"","range":"0 mm to 2000 mm","cmc":"(4,5.L + 1,7) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 2000 mm","cmc":"(4,5.L + 1,7) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 2000 mm","cmc":"(4,5.L + 1,7) µm"}],"technique":"Pomiar na 3D WMP","technique_en":"Measurement by a 3D CMM","technique_zh":"在三维坐标测量机上测量","technique_cs":"Měření na 3D SMS","techniques":["Pomiar na 3D WMP"],"techniques_en":["Measurement by a 3D CMM"],"techniques_zh":["在三维坐标测量机上测量"],"techniques_cs":["Měření na 3D SMS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 2000 mm CMC (4,5.L + 1,7) µm\nPomiar na 3D WMP","reference":"KP D12","norm_bases":["KP D12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany, przyrządy pomiarowe, wzorniki, przyrządy do pomiaru płaskości i kąta Wzorcowanie – długość Pomiar na 3D WMP od 0 mm do 2000 mm CMC (4,5.L + 1,7) µm Kalibry, měřicí přípravky, šablony, měřidla roviny a úhlu Kalibrace – délka Měření na 3D SMS 0 mm až 2000 mm CMC (4,5.L + 1,7) µm KP D12 Sprawdziany, przyrzady pomiarowe, wzorniki, przyrzady do pomiaru plaskosci i kata Wzorcowanie – dlugosc Pomiar na 3D WMP od 0 mm do 2000 mm CMC (4,5.L + 1,7) µm Kalibry, merici pripravky, sablony, meridla roviny a uhlu Kalibrace – delka Mereni na 3D SMS 0 mm az 2000 mm CMC (4,5.L + 1,7) µm KP D12","search_en":"Gauges, measuring jigs, templates, meters of plane and angle Calibration – length Measurement by a 3D CMM 0 mm to 2000 mm CMC (4,5.L + 1,7) µm KP D12","search_zh":"量规、测量夹具、样板、平面和角度量具 校准 – 长度 在三维坐标测量机上测量 0 mm 至 2000 mm CMC (4,5.L + 1,7) µm KP D12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b2b977e5a5a2bef851c5fdc","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"15","test_object":"Projektory profilowe, mikroskopy pomiarowe","test_object_en":"Profile projectors, measuring microscopes","test_object_zh":"轮廓投影仪、测量显微镜","test_object_cs":"Profilprojektory, měřicí mikroskopy","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 600 mm","cmc":"(1.L + 2,6) µm"}],"parameters_en":[{"name":"","range":"0 mm to 600 mm","cmc":"(1.L + 2,6) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 600 mm","cmc":"(1.L + 2,6) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 600 mm","cmc":"(1.L + 2,6) µm"}],"technique":"Pomiar porównawczy z liniałem","technique_en":"Comparative measurement using a rule","technique_zh":"用标准尺比较测量","technique_cs":"Porovnávací měření s pravítkem","techniques":["Pomiar porównawczy z liniałem"],"techniques_en":["Comparative measurement using a rule"],"techniques_zh":["用标准尺比较测量"],"techniques_cs":["Porovnávací měření s pravítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 600 mm CMC (1.L + 2,6) µm\nPomiar porównawczy z liniałem","reference":"KP D13","norm_bases":["KP D13"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Projektory profilowe, mikroskopy pomiarowe Wzorcowanie – długość Pomiar porównawczy z liniałem od 0 mm do 600 mm CMC (1.L + 2,6) µm Profilprojektory, měřicí mikroskopy Kalibrace – délka Porovnávací měření s pravítkem 0 mm až 600 mm CMC (1.L + 2,6) µm KP D13 Projektory profilowe, mikroskopy pomiarowe Wzorcowanie – dlugosc Pomiar porownawczy z linialem od 0 mm do 600 mm CMC (1.L + 2,6) µm Profilprojektory, merici mikroskopy Kalibrace – delka Porovnavaci mereni s pravitkem 0 mm az 600 mm CMC (1.L + 2,6) µm KP D13","search_en":"Profile projectors, measuring microscopes Calibration – length Comparative measurement using a rule 0 mm to 600 mm CMC (1.L + 2,6) µm KP D13","search_zh":"轮廓投影仪、测量显微镜 校准 – 长度 用标准尺比较测量 0 mm 至 600 mm CMC (1.L + 2,6) µm KP D13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a46bb2e3f42feae715f4ee8c","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"16","test_object":"Pomiar prostoliniowości, pomiar liniowy, pomiar płaskości przyrządów warsztatowych","test_object_en":"Measurement of straightness, linear sensing, measurement of flatness of engineering gauges","test_object_zh":"机械量具的直线度测量、线性测量、平面度测量","test_object_cs":"Měření přímosti, lineární snímání, měření rovinnosti strojírenských měřidel","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"prostoliniowość","range":"od 0 m do 20 m","cmc":"(1.L + 0,1) µm"},{"name":"płaskość","range":"od 0 m do 20 m","cmc":"1,5 µm/m²"}],"parameters_en":[{"name":"straightness","range":"0 m to 20 m","cmc":"(1.L + 0,1) µm"},{"name":"flatness","range":"0 m to 20 m","cmc":"1,5 µm/m²"}],"parameters_zh":[{"name":"直线度","range":"0 m 至 20 m","cmc":"(1.L + 0,1) µm"},{"name":"平面度","range":"0 m 至 20 m","cmc":"1,5 µm/m²"}],"parameters_cs":[{"name":"přímost","range":"0 m až 20 m","cmc":"(1.L + 0,1) µm"},{"name":"rovinnost","range":"0 m až 20 m","cmc":"1,5 µm/m²"}],"technique":"Pomiar bezpośredni interferometrem laserowym","technique_en":"Direct measurement by a laser interferometer","technique_zh":"用激光干涉仪直接测量","technique_cs":"Přímé měření laserinterferometrem","techniques":["Pomiar bezpośredni interferometrem laserowym"],"techniques_en":["Direct measurement by a laser interferometer"],"techniques_zh":["用激光干涉仪直接测量"],"techniques_cs":["Přímé měření laserinterferometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nprostoliniowość od 0 m do 20 m CMC (1.L + 0,1) µm\npłaskość od 0 m do 20 m CMC 1,5 µm/m²\nPomiar bezpośredni interferometrem laserowym","reference":"KP D14","norm_bases":["KP D14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomiar prostoliniowości, pomiar liniowy, pomiar płaskości przyrządów warsztatowych Wzorcowanie – długość Pomiar bezpośredni interferometrem laserowym prostoliniowość od 0 m do 20 m CMC (1.L + 0,1) µm płaskość od 0 m do 20 m CMC 1,5 µm/m² Měření přímosti, lineární snímání, měření rovinnosti strojírenských měřidel Kalibrace – délka Přímé měření laserinterferometrem přímost 0 m až 20 m CMC (1.L + 0,1) µm rovinnost 0 m až 20 m CMC 1,5 µm/m² KP D14 Pomiar prostoliniowosci, pomiar liniowy, pomiar plaskosci przyrzadow warsztatowych Wzorcowanie – dlugosc Pomiar bezposredni interferometrem laserowym prostoliniowosc od 0 m do 20 m CMC (1.L + 0,1) µm plaskosc od 0 m do 20 m CMC 1,5 µm/m² Mereni primosti, linearni snimani, mereni rovinnosti strojirenskych meridel Kalibrace – delka Prime mereni laserinterferometrem primost 0 m az 20 m CMC (1.L + 0,1) µm rovinnost 0 m az 20 m CMC 1,5 µm/m² KP D14","search_en":"Measurement of straightness, linear sensing, measurement of flatness of engineering gauges Calibration – length Direct measurement by a laser interferometer straightness 0 m to 20 m CMC (1.L + 0,1) µm flatness 0 m to 20 m CMC 1,5 µm/m² KP D14","search_zh":"机械量具的直线度测量、线性测量、平面度测量 校准 – 长度 用激光干涉仪直接测量 直线度 0 m 至 20 m CMC (1.L + 0,1) µm 平面度 0 m 至 20 m CMC 1,5 µm/m² KP D14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"937c21f3d85db7df674dff33","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"17","test_object":"Sprawdziany, przyrządy pomiarowe, wzorce specjalne","test_object_en":"Gauges, measuring jigs, special meters","test_object_zh":"量规、测量夹具、专用量块","test_object_cs":"Kalibry, měřicí přípravky, speciální měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 600 mm","cmc":"(2,5.L + 1,2) µm"}],"parameters_en":[{"name":"","range":"0 mm to 600 mm","cmc":"(2,5.L + 1,2) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 600 mm","cmc":"(2,5.L + 1,2) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 600 mm","cmc":"(2,5.L + 1,2) µm"}],"technique":"Pomiar na liniowym wysokościomierzu","technique_en":"Measurement by a linear height gauge","technique_zh":"在线性高度仪上测量","technique_cs":"Měření na lineárním výškoměru","techniques":["Pomiar na liniowym wysokościomierzu"],"techniques_en":["Measurement by a linear height gauge"],"techniques_zh":["在线性高度仪上测量"],"techniques_cs":["Měření na lineárním výškoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 600 mm CMC (2,5.L + 1,2) µm\nPomiar na liniowym wysokościomierzu","reference":"KP D15","norm_bases":["KP D15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany, przyrządy pomiarowe, wzorce specjalne Wzorcowanie – długość Pomiar na liniowym wysokościomierzu od 0 mm do 600 mm CMC (2,5.L + 1,2) µm Kalibry, měřicí přípravky, speciální měrky Kalibrace – délka Měření na lineárním výškoměru 0 mm až 600 mm CMC (2,5.L + 1,2) µm KP D15 Sprawdziany, przyrzady pomiarowe, wzorce specjalne Wzorcowanie – dlugosc Pomiar na liniowym wysokosciomierzu od 0 mm do 600 mm CMC (2,5.L + 1,2) µm Kalibry, merici pripravky, specialni merky Kalibrace – delka Mereni na linearnim vyskomeru 0 mm az 600 mm CMC (2,5.L + 1,2) µm KP D15","search_en":"Gauges, measuring jigs, special meters Calibration – length Measurement by a linear height gauge 0 mm to 600 mm CMC (2,5.L + 1,2) µm KP D15","search_zh":"量规、测量夹具、专用量块 校准 – 长度 在线性高度仪上测量 0 mm 至 600 mm CMC (2,5.L + 1,2) µm KP D15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b76a97ced59055314bace6f7","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"18","test_object":"Wysokościomierze liniowe","test_object_en":"Linear height gauges","test_object_zh":"线性高度仪","test_object_cs":"Lineární výškoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 600 mm","cmc":"(0,8.L + 0,5) µm"}],"parameters_en":[{"name":"","range":"0 mm to 600 mm","cmc":"(0,8.L + 0,5) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 600 mm","cmc":"(0,8.L + 0,5) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 600 mm","cmc":"(0,8.L + 0,5) µm"}],"technique":"Pomiar porównawczy z grzebieniem kalibracyjnym","technique_en":"Comparative measurement by a calibration comb","technique_zh":"用校准梳规比较测量","technique_cs":"Porovnávací měření s kalibračním hřebenem","techniques":["Pomiar porównawczy z grzebieniem kalibracyjnym"],"techniques_en":["Comparative measurement by a calibration comb"],"techniques_zh":["用校准梳规比较测量"],"techniques_cs":["Porovnávací měření s kalibračním hřebenem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 600 mm CMC (0,8.L + 0,5) µm\nPomiar porównawczy z grzebieniem kalibracyjnym","reference":"KP D16","norm_bases":["KP D16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wysokościomierze liniowe Wzorcowanie – długość Pomiar porównawczy z grzebieniem kalibracyjnym od 0 mm do 600 mm CMC (0,8.L + 0,5) µm Lineární výškoměry Kalibrace – délka Porovnávací měření s kalibračním hřebenem 0 mm až 600 mm CMC (0,8.L + 0,5) µm KP D16 Wysokosciomierze liniowe Wzorcowanie – dlugosc Pomiar porownawczy z grzebieniem kalibracyjnym od 0 mm do 600 mm CMC (0,8.L + 0,5) µm Linearni vyskomery Kalibrace – delka Porovnavaci mereni s kalibracnim hrebenem 0 mm az 600 mm CMC (0,8.L + 0,5) µm KP D16","search_en":"Linear height gauges Calibration – length Comparative measurement by a calibration comb 0 mm to 600 mm CMC (0,8.L + 0,5) µm KP D16","search_zh":"线性高度仪 校准 – 长度 用校准梳规比较测量 0 mm 至 600 mm CMC (0,8.L + 0,5) µm KP D16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a813cba5880942cad01f44c2","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"18","test_object":"Wysokościomierze liniowe","test_object_en":"Linear height gauges","test_object_zh":"线性高度仪","test_object_cs":"Lineární výškoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 600 mm do 1000 mm","cmc":"(1.L + 3,0) µm"}],"parameters_en":[{"name":"","range":"600 mm to 1000 mm","cmc":"(1.L + 3,0) µm"}],"parameters_zh":[{"name":"","range":"600 mm 至 1000 mm","cmc":"(1.L + 3,0) µm"}],"parameters_cs":[{"name":"","range":"600 mm až 1000 mm","cmc":"(1.L + 3,0) µm"}],"technique":"Pomiar porównawczy z grzebieniem kalibracyjnym i płytkami wzorcowymi","technique_en":"Comparative measurement by a calibration comb and parallel gauge blocks","technique_zh":"用校准梳规和量块比较测量","technique_cs":"Porovnávací měření s kalibračním hřebenem a koncovými měrkami","techniques":["Pomiar porównawczy z grzebieniem kalibracyjnym i płytkami wzorcowymi"],"techniques_en":["Comparative measurement by a calibration comb and parallel gauge blocks"],"techniques_zh":["用校准梳规和量块比较测量"],"techniques_cs":["Porovnávací měření s kalibračním hřebenem a koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 600 mm do 1000 mm CMC (1.L + 3,0) µm\nPomiar porównawczy z grzebieniem kalibracyjnym i płytkami wzorcowymi","reference":"KP D16","norm_bases":["KP D16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wysokościomierze liniowe Wzorcowanie – długość Pomiar porównawczy z grzebieniem kalibracyjnym i płytkami wzorcowymi od 600 mm do 1000 mm CMC (1.L + 3,0) µm Lineární výškoměry Kalibrace – délka Porovnávací měření s kalibračním hřebenem a koncovými měrkami 600 mm až 1000 mm CMC (1.L + 3,0) µm KP D16 Wysokosciomierze liniowe Wzorcowanie – dlugosc Pomiar porownawczy z grzebieniem kalibracyjnym i plytkami wzorcowymi od 600 mm do 1000 mm CMC (1.L + 3,0) µm Linearni vyskomery Kalibrace – delka Porovnavaci mereni s kalibracnim hrebenem a koncovymi merkami 600 mm az 1000 mm CMC (1.L + 3,0) µm KP D16","search_en":"Linear height gauges Calibration – length Comparative measurement by a calibration comb and parallel gauge blocks 600 mm to 1000 mm CMC (1.L + 3,0) µm KP D16","search_zh":"线性高度仪 校准 – 长度 用校准梳规和量块比较测量 600 mm 至 1000 mm CMC (1.L + 3,0) µm KP D16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c8df848e48098e8ac1b3781e","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"19","test_object":"Konturografy","test_object_en":"Contourographs","test_object_zh":"轮廓仪","test_object_cs":"Konturoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"(1.L + 2,6) µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"(1.L + 2,6) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"(1.L + 2,6) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"(1.L + 2,6) µm"}],"technique":"Pomiar porównawczy z wzorcami końcowymi","technique_en":"Comparative measurement using end standards","technique_zh":"用端度标准比较测量","technique_cs":"Porovnávací měření s koncovými etalony","techniques":["Pomiar porównawczy z wzorcami końcowymi"],"techniques_en":["Comparative measurement using end standards"],"techniques_zh":["用端度标准比较测量"],"techniques_cs":["Porovnávací měření s koncovými etalony"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC (1.L + 2,6) µm\nPomiar porównawczy z wzorcami końcowymi","reference":"KP D17","norm_bases":["KP D17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konturografy Wzorcowanie – długość Pomiar porównawczy z wzorcami końcowymi od 0 mm do 100 mm CMC (1.L + 2,6) µm Konturoměry Kalibrace – délka Porovnávací měření s koncovými etalony 0 mm až 100 mm CMC (1.L + 2,6) µm KP D17 Konturografy Wzorcowanie – dlugosc Pomiar porownawczy z wzorcami koncowymi od 0 mm do 100 mm CMC (1.L + 2,6) µm Konturomery Kalibrace – delka Porovnavaci mereni s koncovymi etalony 0 mm az 100 mm CMC (1.L + 2,6) µm KP D17","search_en":"Contourographs Calibration – length Comparative measurement using end standards 0 mm to 100 mm CMC (1.L + 2,6) µm KP D17","search_zh":"轮廓仪 校准 – 长度 用端度标准比较测量 0 mm 至 100 mm CMC (1.L + 2,6) µm KP D17","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"747976b2fcc51218c07761fc","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"20","test_object":"Długościomierze","test_object_en":"Length measuring instruments","test_object_zh":"测长仪","test_object_cs":"Délkoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 20000 mm","cmc":"(2.L + 0,2) µm"}],"parameters_en":[{"name":"","range":"0 mm to 20000 mm","cmc":"(2.L + 0,2) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 20000 mm","cmc":"(2.L + 0,2) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 20000 mm","cmc":"(2.L + 0,2) µm"}],"technique":"Pomiar bezpośredni interferometrem laserowym","technique_en":"Direct measurement by a laser interferometer","technique_zh":"用激光干涉仪直接测量","technique_cs":"Přímé měření laserinterferometrem","techniques":["Pomiar bezpośredni interferometrem laserowym"],"techniques_en":["Direct measurement by a laser interferometer"],"techniques_zh":["用激光干涉仪直接测量"],"techniques_cs":["Přímé měření laserinterferometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 20000 mm CMC (2.L + 0,2) µm\nPomiar bezpośredni interferometrem laserowym","reference":"KP D18","norm_bases":["KP D18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długościomierze Wzorcowanie – długość Pomiar bezpośredni interferometrem laserowym od 0 mm do 20000 mm CMC (2.L + 0,2) µm Délkoměry Kalibrace – délka Přímé měření laserinterferometrem 0 mm až 20000 mm CMC (2.L + 0,2) µm KP D18 Dlugosciomierze Wzorcowanie – dlugosc Pomiar bezposredni interferometrem laserowym od 0 mm do 20000 mm CMC (2.L + 0,2) µm Delkomery Kalibrace – delka Prime mereni laserinterferometrem 0 mm az 20000 mm CMC (2.L + 0,2) µm KP D18","search_en":"Length measuring instruments Calibration – length Direct measurement by a laser interferometer 0 mm to 20000 mm CMC (2.L + 0,2) µm KP D18","search_zh":"测长仪 校准 – 长度 用激光干涉仪直接测量 0 mm 至 20000 mm CMC (2.L + 0,2) µm KP D18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15cf15c4fbfad5754195a23d","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"21","test_object":"Współrzędnościowe maszyny pomiarowe 3D","test_object_en":"3D coordinate measuring machines","test_object_zh":"三维坐标测量机","test_object_cs":"3D souřadnicové měřicí stroje","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 600 mm","cmc":"(2.L + 0,2) µm"}],"parameters_en":[{"name":"","range":"0 mm to 600 mm","cmc":"(2.L + 0,2) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 600 mm","cmc":"(2.L + 0,2) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 600 mm","cmc":"(2.L + 0,2) µm"}],"technique":"Pomiar porównawczy grzebieniem kalibracyjnym","technique_en":"Comparative measurement by a calibration comb","technique_zh":"用校准梳规比较测量","technique_cs":"Porovnávací měření kalibračním hřebenem","techniques":["Pomiar porównawczy grzebieniem kalibracyjnym"],"techniques_en":["Comparative measurement by a calibration comb"],"techniques_zh":["用校准梳规比较测量"],"techniques_cs":["Porovnávací měření kalibračním hřebenem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 600 mm CMC (2.L + 0,2) µm\nPomiar porównawczy grzebieniem kalibracyjnym","reference":"KP D19","norm_bases":["KP D19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe 3D Wzorcowanie – długość Pomiar porównawczy grzebieniem kalibracyjnym od 0 mm do 600 mm CMC (2.L + 0,2) µm 3D souřadnicové měřicí stroje Kalibrace – délka Porovnávací měření kalibračním hřebenem 0 mm až 600 mm CMC (2.L + 0,2) µm KP D19 Wspolrzednosciowe maszyny pomiarowe 3D Wzorcowanie – dlugosc Pomiar porownawczy grzebieniem kalibracyjnym od 0 mm do 600 mm CMC (2.L + 0,2) µm 3D souradnicove merici stroje Kalibrace – delka Porovnavaci mereni kalibracnim hrebenem 0 mm az 600 mm CMC (2.L + 0,2) µm KP D19","search_en":"3D coordinate measuring machines Calibration – length Comparative measurement by a calibration comb 0 mm to 600 mm CMC (2.L + 0,2) µm KP D19","search_zh":"三维坐标测量机 校准 – 长度 用校准梳规比较测量 0 mm 至 600 mm CMC (2.L + 0,2) µm KP D19","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"49acab4756c9222f1db2956e","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"21","test_object":"Współrzędnościowe maszyny pomiarowe 3D","test_object_en":"3D coordinate measuring machines","test_object_zh":"三维坐标测量机","test_object_cs":"3D souřadnicové měřicí stroje","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 600 mm do 1000 mm","cmc":"(2.L + 0,2) µm"}],"parameters_en":[{"name":"","range":"600 mm to 1000 mm","cmc":"(2.L + 0,2) µm"}],"parameters_zh":[{"name":"","range":"600 mm 至 1000 mm","cmc":"(2.L + 0,2) µm"}],"parameters_cs":[{"name":"","range":"600 mm až 1000 mm","cmc":"(2.L + 0,2) µm"}],"technique":"Pomiar porównawczy grzebieniem kalibracyjnym i płytkami wzorcowymi","technique_en":"Comparative measurement by a calibration comb and parallel gauge blocks","technique_zh":"用校准梳规和量块比较测量","technique_cs":"Porovnávací měření kalibračního hřebene a koncových měrek","techniques":["Pomiar porównawczy grzebieniem kalibracyjnym i płytkami wzorcowymi"],"techniques_en":["Comparative measurement by a calibration comb and parallel gauge blocks"],"techniques_zh":["用校准梳规和量块比较测量"],"techniques_cs":["Porovnávací měření kalibračního hřebene a koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 600 mm do 1000 mm CMC (2.L + 0,2) µm\nPomiar porównawczy grzebieniem kalibracyjnym i płytkami wzorcowymi","reference":"KP D19","norm_bases":["KP D19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe 3D Wzorcowanie – długość Pomiar porównawczy grzebieniem kalibracyjnym i płytkami wzorcowymi od 600 mm do 1000 mm CMC (2.L + 0,2) µm 3D souřadnicové měřicí stroje Kalibrace – délka Porovnávací měření kalibračního hřebene a koncových měrek 600 mm až 1000 mm CMC (2.L + 0,2) µm KP D19 Wspolrzednosciowe maszyny pomiarowe 3D Wzorcowanie – dlugosc Pomiar porownawczy grzebieniem kalibracyjnym i plytkami wzorcowymi od 600 mm do 1000 mm CMC (2.L + 0,2) µm 3D souradnicove merici stroje Kalibrace – delka Porovnavaci mereni kalibracniho hrebene a koncovych merek 600 mm az 1000 mm CMC (2.L + 0,2) µm KP D19","search_en":"3D coordinate measuring machines Calibration – length Comparative measurement by a calibration comb and parallel gauge blocks 600 mm to 1000 mm CMC (2.L + 0,2) µm KP D19","search_zh":"三维坐标测量机 校准 – 长度 用校准梳规和量块比较测量 600 mm 至 1000 mm CMC (2.L + 0,2) µm KP D19","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0bc1444ece5efe2944c7c42d","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"21","test_object":"Współrzędnościowe maszyny pomiarowe 3D","test_object_en":"3D coordinate measuring machines","test_object_zh":"三维坐标测量机","test_object_cs":"3D souřadnicové měřicí stroje","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 10000 mm","cmc":"(1.L + 0,1) µm"}],"parameters_en":[{"name":"","range":"0 mm to 10000 mm","cmc":"(1.L + 0,1) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 10000 mm","cmc":"(1.L + 0,1) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 10000 mm","cmc":"(1.L + 0,1) µm"}],"technique":"Pomiar bezpośredni interferometrem laserowym","technique_en":"Direct measurement by a laser interferometer","technique_zh":"用激光干涉仪直接测量","technique_cs":"Přímé měření laserinterferometrem","techniques":["Pomiar bezpośredni interferometrem laserowym"],"techniques_en":["Direct measurement by a laser interferometer"],"techniques_zh":["用激光干涉仪直接测量"],"techniques_cs":["Přímé měření laserinterferometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 10000 mm CMC (1.L + 0,1) µm\nPomiar bezpośredni interferometrem laserowym","reference":"KP D19","norm_bases":["KP D19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe 3D Wzorcowanie – długość Pomiar bezpośredni interferometrem laserowym od 0 mm do 10000 mm CMC (1.L + 0,1) µm 3D souřadnicové měřicí stroje Kalibrace – délka Přímé měření laserinterferometrem 0 mm až 10000 mm CMC (1.L + 0,1) µm KP D19 Wspolrzednosciowe maszyny pomiarowe 3D Wzorcowanie – dlugosc Pomiar bezposredni interferometrem laserowym od 0 mm do 10000 mm CMC (1.L + 0,1) µm 3D souradnicove merici stroje Kalibrace – delka Prime mereni laserinterferometrem 0 mm az 10000 mm CMC (1.L + 0,1) µm KP D19","search_en":"3D coordinate measuring machines Calibration – length Direct measurement by a laser interferometer 0 mm to 10000 mm CMC (1.L + 0,1) µm KP D19","search_zh":"三维坐标测量机 校准 – 长度 用激光干涉仪直接测量 0 mm 至 10000 mm CMC (1.L + 0,1) µm KP D19","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"77d7fb08f0e066aea674a207","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"22","test_object":"Sprawdziany, wzorce specjalne, przyrządy pomiarowe, wzorniki, przymiary","test_object_en":"Gauges, special meters, measuring jigs, templates, rules","test_object_zh":"量规、专用量块、测量夹具、样板、直尺","test_object_cs":"Kalibry, speciální měrky, měřicí přípravky, šablony, měřítka","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 330 mm","cmc":"(2.L + 3,5) µm"}],"parameters_en":[{"name":"","range":"0 mm to 330 mm","cmc":"(2.L + 3,5) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 330 mm","cmc":"(2.L + 3,5) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 330 mm","cmc":"(2.L + 3,5) µm"}],"technique":"Pomiar bezpośredni na mikroskopie 2D","technique_en":"Direct measurement by a 2D microscope","technique_zh":"在二维显微镜上直接测量","technique_cs":"Přímé měření na 2D mikroskopu","techniques":["Pomiar bezpośredni na mikroskopie 2D"],"techniques_en":["Direct measurement by a 2D microscope"],"techniques_zh":["在二维显微镜上直接测量"],"techniques_cs":["Přímé měření na 2D mikroskopu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 330 mm CMC (2.L + 3,5) µm\nPomiar bezpośredni na mikroskopie 2D","reference":"KP D20","norm_bases":["KP D20"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany, wzorce specjalne, przyrządy pomiarowe, wzorniki, przymiary Wzorcowanie – długość Pomiar bezpośredni na mikroskopie 2D od 0 mm do 330 mm CMC (2.L + 3,5) µm Kalibry, speciální měrky, měřicí přípravky, šablony, měřítka Kalibrace – délka Přímé měření na 2D mikroskopu 0 mm až 330 mm CMC (2.L + 3,5) µm KP D20 Sprawdziany, wzorce specjalne, przyrzady pomiarowe, wzorniki, przymiary Wzorcowanie – dlugosc Pomiar bezposredni na mikroskopie 2D od 0 mm do 330 mm CMC (2.L + 3,5) µm Kalibry, specialni merky, merici pripravky, sablony, meritka Kalibrace – delka Prime mereni na 2D mikroskopu 0 mm az 330 mm CMC (2.L + 3,5) µm KP D20","search_en":"Gauges, special meters, measuring jigs, templates, rules Calibration – length Direct measurement by a 2D microscope 0 mm to 330 mm CMC (2.L + 3,5) µm KP D20","search_zh":"量规、专用量块、测量夹具、样板、直尺 校准 – 长度 在二维显微镜上直接测量 0 mm 至 330 mm CMC (2.L + 3,5) µm KP D20","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e77faf40a340774f7ddd03d8","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"23","test_object":"Liniały krawędziowe i powierzchniowe","test_object_en":"Blade and surface rules","test_object_zh":"刀口尺和平尺","test_object_cs":"Nožová a příměrná pravítka","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 2000 mm","cmc":"(5.L + 2) µm"}],"parameters_en":[{"name":"","range":"0 mm to 2000 mm","cmc":"(5.L + 2) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 2000 mm","cmc":"(5.L + 2) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 2000 mm","cmc":"(5.L + 2) µm"}],"technique":"Pomiar bezpośredni na płycie","technique_en":"Direct measurement on a plate","technique_zh":"在平板上直接测量","technique_cs":"Přímé měření na desce","techniques":["Pomiar bezpośredni na płycie"],"techniques_en":["Direct measurement on a plate"],"techniques_zh":["在平板上直接测量"],"techniques_cs":["Přímé měření na desce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 2000 mm CMC (5.L + 2) µm\nPomiar bezpośredni na płycie","reference":"KP D21","norm_bases":["KP D21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Liniały krawędziowe i powierzchniowe Wzorcowanie – długość Pomiar bezpośredni na płycie od 0 mm do 2000 mm CMC (5.L + 2) µm Nožová a příměrná pravítka Kalibrace – délka Přímé měření na desce 0 mm až 2000 mm CMC (5.L + 2) µm KP D21 Linialy krawedziowe i powierzchniowe Wzorcowanie – dlugosc Pomiar bezposredni na plycie od 0 mm do 2000 mm CMC (5.L + 2) µm Nozova a primerna pravitka Kalibrace – delka Prime mereni na desce 0 mm az 2000 mm CMC (5.L + 2) µm KP D21","search_en":"Blade and surface rules Calibration – length Direct measurement on a plate 0 mm to 2000 mm CMC (5.L + 2) µm KP D21","search_zh":"刀口尺和平尺 校准 – 长度 在平板上直接测量 0 mm 至 2000 mm CMC (5.L + 2) µm KP D21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5715399f915429d820b5138","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"23","test_object":"Liniały krawędziowe i powierzchniowe","test_object_en":"Blade and surface rules","test_object_zh":"刀口尺和平尺","test_object_cs":"Nožová a příměrná pravítka","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 2000 mm do 3000 mm","cmc":"(5.L + 12) µm"}],"parameters_en":[{"name":"","range":"2000 mm to 3000 mm","cmc":"(5.L + 12) µm"}],"parameters_zh":[{"name":"","range":"2000 mm 至 3000 mm","cmc":"(5.L + 12) µm"}],"parameters_cs":[{"name":"","range":"2000 mm až 3000 mm","cmc":"(5.L + 12) µm"}],"technique":"Pomiar na łożu","technique_en":"Measurement on a bed","technique_zh":"在床身上测量","technique_cs":"Měření na loži","techniques":["Pomiar na łożu"],"techniques_en":["Measurement on a bed"],"techniques_zh":["在床身上测量"],"techniques_cs":["Měření na loži"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 2000 mm do 3000 mm CMC (5.L + 12) µm\nPomiar na łożu","reference":"KP D21","norm_bases":["KP D21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Liniały krawędziowe i powierzchniowe Wzorcowanie – długość Pomiar na łożu od 2000 mm do 3000 mm CMC (5.L + 12) µm Nožová a příměrná pravítka Kalibrace – délka Měření na loži 2000 mm až 3000 mm CMC (5.L + 12) µm KP D21 Linialy krawedziowe i powierzchniowe Wzorcowanie – dlugosc Pomiar na lozu od 2000 mm do 3000 mm CMC (5.L + 12) µm Nozova a primerna pravitka Kalibrace – delka Mereni na lozi 2000 mm az 3000 mm CMC (5.L + 12) µm KP D21","search_en":"Blade and surface rules Calibration – length Measurement on a bed 2000 mm to 3000 mm CMC (5.L + 12) µm KP D21","search_zh":"刀口尺和平尺 校准 – 长度 在床身上测量 2000 mm 至 3000 mm CMC (5.L + 12) µm KP D21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"209f5d5e93c0612f5216b558","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"24","test_object":"Chropowatościomierze","test_object_en":"Roughness meters","test_object_zh":"粗糙度仪","test_object_cs":"Drsnoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,01 µm do 6000 µm","cmc":"5 %"}],"parameters_en":[{"name":"","range":"0,01 µm to 6000 µm","cmc":"5 %"}],"parameters_zh":[{"name":"","range":"0,01 µm 至 6000 µm","cmc":"5 %"}],"parameters_cs":[{"name":"","range":"0,01 µm až 6000 µm","cmc":"5 %"}],"technique":"Pomiar porównawczy z wzorcem chropowatości","technique_en":"Comparative measurement by a roughness reference standard","technique_zh":"与粗糙度标准比较测量","technique_cs":"Porovnávací měření s etalonem drsnosti","techniques":["Pomiar porównawczy z wzorcem chropowatości"],"techniques_en":["Comparative measurement by a roughness reference standard"],"techniques_zh":["与粗糙度标准比较测量"],"techniques_cs":["Porovnávací měření s etalonem drsnosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,01 µm do 6000 µm CMC 5 %\nPomiar porównawczy z wzorcem chropowatości","reference":"KP DR1","norm_bases":["KP DR1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Chropowatościomierze Wzorcowanie – długość Pomiar porównawczy z wzorcem chropowatości od 0,01 µm do 6000 µm CMC 5 % Drsnoměry Kalibrace – délka Porovnávací měření s etalonem drsnosti 0,01 µm až 6000 µm CMC 5 % KP DR1 Chropowatosciomierze Wzorcowanie – dlugosc Pomiar porownawczy z wzorcem chropowatosci od 0,01 µm do 6000 µm CMC 5 % Drsnomery Kalibrace – delka Porovnavaci mereni s etalonem drsnosti 0,01 µm az 6000 µm CMC 5 % KP DR1","search_en":"Roughness meters Calibration – length Comparative measurement by a roughness reference standard 0,01 µm to 6000 µm CMC 5 % KP DR1","search_zh":"粗糙度仪 校准 – 长度 与粗糙度标准比较测量 0,01 µm 至 6000 µm CMC 5 % KP DR1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"997f9bc70f0b5d6e484bd44d","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"25","test_object":"Wzorce chropowatości","test_object_en":"Roughness standards","test_object_zh":"粗糙度标准样块","test_object_cs":"Etalony drsnosti","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,01 µm do 6000 µm","cmc":"5 %"}],"parameters_en":[{"name":"","range":"0,01 µm to 6000 µm","cmc":"5 %"}],"parameters_zh":[{"name":"","range":"0,01 µm 至 6000 µm","cmc":"5 %"}],"parameters_cs":[{"name":"","range":"0,01 µm až 6000 µm","cmc":"5 %"}],"technique":"Pomiar bezpośredni na chropowatościomierzu","technique_en":"Direct measurement by a roughness meter","technique_zh":"在粗糙度仪上直接测量","technique_cs":"Přímé měření na drsnoměru","techniques":["Pomiar bezpośredni na chropowatościomierzu"],"techniques_en":["Direct measurement by a roughness meter"],"techniques_zh":["在粗糙度仪上直接测量"],"techniques_cs":["Přímé měření na drsnoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,01 µm do 6000 µm CMC 5 %\nPomiar bezpośredni na chropowatościomierzu","reference":"KP DR1","norm_bases":["KP DR1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorce chropowatości Wzorcowanie – długość Pomiar bezpośredni na chropowatościomierzu od 0,01 µm do 6000 µm CMC 5 % Etalony drsnosti Kalibrace – délka Přímé měření na drsnoměru 0,01 µm až 6000 µm CMC 5 % KP DR1 Wzorce chropowatosci Wzorcowanie – dlugosc Pomiar bezposredni na chropowatosciomierzu od 0,01 µm do 6000 µm CMC 5 % Etalony drsnosti Kalibrace – delka Prime mereni na drsnomeru 0,01 µm az 6000 µm CMC 5 % KP DR1","search_en":"Roughness standards Calibration – length Direct measurement by a roughness meter 0,01 µm to 6000 µm CMC 5 % KP DR1","search_zh":"粗糙度标准样块 校准 – 长度 在粗糙度仪上直接测量 0,01 µm 至 6000 µm CMC 5 % KP DR1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"919eedb34544854ac93e04ed","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"26","test_object":"Kątowniki od 0° do 180°","test_object_en":"Angles from 0° to 180°","test_object_zh":"0° 至 180° 角尺","test_object_cs":"Úhelníky od 0° do 180°","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Długość ramienia do 3 m","range":"od 0 mm do 7 mm","cmc":"(4,5.L + 2) µm"}],"parameters_en":[{"name":"Length of the arm up to 3 m","range":"0 mm to 7 mm","cmc":"(4,5.L + 2) µm"}],"parameters_zh":[{"name":"臂长至 3 m","range":"0 mm 至 7 mm","cmc":"(4,5.L + 2) µm"}],"parameters_cs":[{"name":"Délka ramene do 3 m","range":"0 mm až 7 mm","cmc":"(4,5.L + 2) µm"}],"technique":"Pomiar bezpośredni na 3D WMP","technique_en":"Direct measurement by a 3D CMM","technique_zh":"在三维坐标测量机上直接测量","technique_cs":"Přímé měření na 3D SMS","techniques":["Pomiar bezpośredni na 3D WMP"],"techniques_en":["Direct measurement by a 3D CMM"],"techniques_zh":["在三维坐标测量机上直接测量"],"techniques_cs":["Přímé měření na 3D SMS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nDługość ramienia do 3 m od 0 mm do 7 mm CMC (4,5.L + 2) µm\nPomiar bezpośredni na 3D WMP","reference":"KP R2","norm_bases":["KP R2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątowniki od 0° do 180° Wzorcowanie – długość Pomiar bezpośredni na 3D WMP Długość ramienia do 3 m od 0 mm do 7 mm CMC (4,5.L + 2) µm Úhelníky od 0° do 180° Kalibrace – délka Přímé měření na 3D SMS Délka ramene do 3 m 0 mm až 7 mm CMC (4,5.L + 2) µm KP R2 Katowniki od 0° do 180° Wzorcowanie – dlugosc Pomiar bezposredni na 3D WMP Dlugosc ramienia do 3 m od 0 mm do 7 mm CMC (4,5.L + 2) µm Uhelniky od 0° do 180° Kalibrace – delka Prime mereni na 3D SMS Delka ramene do 3 m 0 mm az 7 mm CMC (4,5.L + 2) µm KP R2","search_en":"Angles from 0° to 180° Calibration – length Direct measurement by a 3D CMM Length of the arm up to 3 m 0 mm to 7 mm CMC (4,5.L + 2) µm KP R2","search_zh":"0° 至 180° 角尺 校准 – 长度 在三维坐标测量机上直接测量 臂长至 3 m 0 mm 至 7 mm CMC (4,5.L + 2) µm KP R2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f6e0ff910fa315614b438e40","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Poziomnice murarskie, cieczowe maszynowe","test_object_en":"Levels – builder's, liquid, machine","test_object_zh":"建筑水平尺、液体机械水平仪","test_object_cs":"Libely zednické, kapalinové strojní","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"Czułość działki od 0,01 mm/m","range":"od -52 mm/m do 52 mm/m","cmc":"0,005 mm/m"}],"parameters_en":[{"name":"Division sensitivity from 0.01 mm/m","range":"-52 mm/m to 52 mm/m","cmc":"0,005 mm/m"}],"parameters_zh":[{"name":"分度灵敏度自 0,01 mm/m 起","range":"-52 mm/m 至 52 mm/m","cmc":"0,005 mm/m"}],"parameters_cs":[{"name":"Citlivost na dílek od 0,01 mm/m","range":"-52 mm/m až 52 mm/m","cmc":"0,005 mm/m"}],"technique":"Pomiar bezpośredni na generatorze małych kątów","technique_en":"Direct measurement by a small angle generator","technique_zh":"在小角度发生器上直接测量","technique_cs":"Přímé měření na generátoru malých úhlů","techniques":["Pomiar bezpośredni na generatorze małych kątów"],"techniques_en":["Direct measurement by a small angle generator"],"techniques_zh":["在小角度发生器上直接测量"],"techniques_cs":["Přímé měření na generátoru malých úhlů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nCzułość działki od 0,01 mm/m od -52 mm/m do 52 mm/m CMC 0,005 mm/m\nPomiar bezpośredni na generatorze małych kątów","reference":"KP R1","norm_bases":["KP R1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Poziomnice murarskie, cieczowe maszynowe Wzorcowanie – kąt płaski Pomiar bezpośredni na generatorze małych kątów Czułość działki od 0,01 mm/m od -52 mm/m do 52 mm/m CMC 0,005 mm/m Libely zednické, kapalinové strojní Kalibrace – rovinný úhel Přímé měření na generátoru malých úhlů Citlivost na dílek od 0,01 mm/m -52 mm/m až 52 mm/m CMC 0,005 mm/m KP R1 Poziomnice murarskie, cieczowe maszynowe Wzorcowanie – kat plaski Pomiar bezposredni na generatorze malych katow Czulosc dzialki od 0,01 mm/m od -52 mm/m do 52 mm/m CMC 0,005 mm/m Libely zednicke, kapalinove strojni Kalibrace – rovinny uhel Prime mereni na generatoru malych uhlu Citlivost na dilek od 0,01 mm/m -52 mm/m az 52 mm/m CMC 0,005 mm/m KP R1","search_en":"Levels – builder's, liquid, machine Calibration – plane angle Direct measurement by a small angle generator Division sensitivity from 0.01 mm/m -52 mm/m to 52 mm/m CMC 0,005 mm/m KP R1","search_zh":"建筑水平尺、液体机械水平仪 校准 – 平面角 在小角度发生器上直接测量 分度灵敏度自 0,01 mm/m 起 -52 mm/m 至 52 mm/m CMC 0,005 mm/m KP R1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5341e77fd5f0efd96e6f72e","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Pochyłomierze","test_object_en":"Clinometers","test_object_zh":"倾角仪","test_object_cs":"Sklonoměry","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"Działka od 0,01°","range":"od -180° do 180°","cmc":"0,15°"}],"parameters_en":[{"name":"Division from 0.01°","range":"-180° to 180°","cmc":"0,15°"}],"parameters_zh":[{"name":"分度值自 0,01° 起","range":"-180° 至 180°","cmc":"0,15°"}],"parameters_cs":[{"name":"Dělení od 0,01°","range":"-180° až 180°","cmc":"0,15°"}],"technique":"Pomiar bezpośredni na generatorze małych kątów","technique_en":"Direct measurement by a small angle generator","technique_zh":"在小角度发生器上直接测量","technique_cs":"Přímé měření na generátoru malých úhlů","techniques":["Pomiar bezpośredni na generatorze małych kątów"],"techniques_en":["Direct measurement by a small angle generator"],"techniques_zh":["在小角度发生器上直接测量"],"techniques_cs":["Přímé měření na generátoru malých úhlů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nDziałka od 0,01° od -180° do 180° CMC 0,15°\nPomiar bezpośredni na generatorze małych kątów","reference":"KP R1","norm_bases":["KP R1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pochyłomierze Wzorcowanie – kąt płaski Pomiar bezpośredni na generatorze małych kątów Działka od 0,01° od -180° do 180° CMC 0,15° Sklonoměry Kalibrace – rovinný úhel Přímé měření na generátoru malých úhlů Dělení od 0,01° -180° až 180° CMC 0,15° KP R1 Pochylomierze Wzorcowanie – kat plaski Pomiar bezposredni na generatorze malych katow Dzialka od 0,01° od -180° do 180° CMC 0,15° Sklonomery Kalibrace – rovinny uhel Prime mereni na generatoru malych uhlu Deleni od 0,01° -180° az 180° CMC 0,15° KP R1","search_en":"Clinometers Calibration – plane angle Direct measurement by a small angle generator Division from 0.01° -180° to 180° CMC 0,15° KP R1","search_zh":"倾角仪 校准 – 平面角 在小角度发生器上直接测量 分度值自 0,01° 起 -180° 至 180° CMC 0,15° KP R1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5a03daf6a36201009a007681","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Kątomierze","test_object_en":"Angle gauges","test_object_zh":"角度尺","test_object_cs":"Úhloměry","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0° do 360°","cmc":"5´"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"5´"}],"parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"5´"}],"parameters_cs":[{"name":"","range":"0° až 360°","cmc":"5´"}],"technique":"Pomiar bezpośredni za pomocą płytek kątowych","technique_en":"Direct measurement using angle gauges","technique_zh":"用角度块直接测量","technique_cs":"Přímé měření pomocí úhlových měrek","techniques":["Pomiar bezpośredni za pomocą płytek kątowych"],"techniques_en":["Direct measurement using angle gauges"],"techniques_zh":["用角度块直接测量"],"techniques_cs":["Přímé měření pomocí úhlových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0° do 360° CMC 5´\nPomiar bezpośredni za pomocą płytek kątowych","reference":"KP R2","norm_bases":["KP R2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątomierze Wzorcowanie – kąt płaski Pomiar bezpośredni za pomocą płytek kątowych od 0° do 360° CMC 5´ Úhloměry Kalibrace – rovinný úhel Přímé měření pomocí úhlových měrek 0° až 360° CMC 5´ KP R2 Katomierze Wzorcowanie – kat plaski Pomiar bezposredni za pomoca plytek katowych od 0° do 360° CMC 5´ Uhlomery Kalibrace – rovinny uhel Prime mereni pomoci uhlovych merek 0° az 360° CMC 5´ KP R2","search_en":"Angle gauges Calibration – plane angle Direct measurement using angle gauges 0° to 360° CMC 5´ KP R2","search_zh":"角度尺 校准 – 平面角 用角度块直接测量 0° 至 360° CMC 5´ KP R2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c052bd7b37da82e296663bf4","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Pipety tłokowe","test_object_en":"Piston pipettes","test_object_zh":"活塞式移液器","test_object_cs":"Pístové pipety","methodology":"Wzorcowanie – objętość, przepływ","methodology_en":"Calibration – volume, flow rate","methodology_zh":"校准 – 体积、流量","methodology_cs":"Kalibrace – objem, průtok","parameters":[{"name":"Woda destylowana","range":"od 0,5 µl do 10000 µl","cmc":"0,13 % + 0,01 µl"}],"parameters_en":[{"name":"Distilled water","range":"0,5 µl to 10000 µl","cmc":"0,13 % + 0,01 µl"}],"parameters_zh":[{"name":"蒸馏水","range":"0,5 µl 至 10000 µl","cmc":"0,13 % + 0,01 µl"}],"parameters_cs":[{"name":"Destilovaná voda","range":"0,5 µl až 10000 µl","cmc":"0,13 % + 0,01 µl"}],"technique":"Metoda grawimetryczna wg ČSN EN ISO 8655-6","technique_en":"Gravimetric method according to ČSN EN ISO 8655-6","technique_zh":"依据 ČSN EN ISO 8655-6 的重量法","technique_cs":"Gravimetrická metoda dle ČSN EN ISO 8655-6","techniques":["Metoda grawimetryczna wg ČSN EN ISO 8655-6"],"techniques_en":["Gravimetric method according to ČSN EN ISO 8655-6"],"techniques_zh":["依据 ČSN EN ISO 8655-6 的重量法"],"techniques_cs":["Gravimetrická metoda dle ČSN EN ISO 8655-6"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość, przepływ\nWoda destylowana od 0,5 µl do 10000 µl CMC 0,13 % + 0,01 µl\nMetoda grawimetryczna wg ČSN EN ISO 8655-6","reference":"KP P1","norm_bases":["KP P1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość, przepływ","regulatory_area_en":"CMC for the field of measured quantity: Volume, flow rate","regulatory_area_zh":"被测量领域的CMC：体积、流量","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem, průtok","flexible":false,"flexibility":null,"outside_premises":false,"note":"Najmniejsza podawana niepewność uwzględnia wpływ operatora, nie uwzględnia składowej statystycznej niepewności","note_en":"The lowest reported uncertainty includes the operator's influence; the statistical component of uncertainty is not included.","note_zh":"所报最小不确定度包含操作者影响，未计入不确定度的统计分量","note_cs":"V nejnižší udávané nejistotě je zahrnut vliv operátora, není započtena statistické složka nejistoty","search_text":"Pipety tłokowe Wzorcowanie – objętość, przepływ Metoda grawimetryczna wg ČSN EN ISO 8655-6 Woda destylowana od 0,5 µl do 10000 µl CMC 0,13 % + 0,01 µl Pístové pipety Kalibrace – objem, průtok Gravimetrická metoda dle ČSN EN ISO 8655-6 Destilovaná voda 0,5 µl až 10000 µl CMC 0,13 % + 0,01 µl KP P1 Pipety tlokowe Wzorcowanie – objetosc, przeplyw Metoda grawimetryczna wg CSN EN ISO 8655-6 Woda destylowana od 0,5 µl do 10000 µl CMC 0,13 % + 0,01 µl Pistove pipety Kalibrace – objem, prutok Gravimetricka metoda dle CSN EN ISO 8655-6 Destilovana voda 0,5 µl az 10000 µl CMC 0,13 % + 0,01 µl KP P1","search_en":"Piston pipettes Calibration – volume, flow rate Gravimetric method according to ČSN EN ISO 8655-6 Distilled water 0,5 µl to 10000 µl CMC 0,13 % + 0,01 µl KP P1","search_zh":"活塞式移液器 校准 – 体积、流量 依据 ČSN EN ISO 8655-6 的重量法 蒸馏水 0,5 µl 至 10000 µl CMC 0,13 % + 0,01 µl KP P1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7544bcb8ee704f53f969f083","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Non-automatic weighing instruments","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"Odważniki klasy E2","range":"od 0,001 g do 2000 g","cmc":"2,7.10⁻⁶"},{"name":"Odważniki klasy F2","range":"od 2 kg do 20 kg","cmc":"1,4.10⁻⁵"},{"name":"Odważniki klasy M1","range":"od 20 kg do 1000 kg","cmc":"5,0.10⁻⁵"}],"parameters_en":[{"name":"E2 class weight","range":"0,001 g to 2000 g","cmc":"2,7.10⁻⁶"},{"name":"F2 class weight","range":"2 kg to 20 kg","cmc":"1,4.10⁻⁵"},{"name":"M1 class weight","range":"20 kg to 1000 kg","cmc":"5,0.10⁻⁵"}],"parameters_zh":[{"name":"E2 级砝码","range":"0,001 g 至 2000 g","cmc":"2,7.10⁻⁶"},{"name":"F2 级砝码","range":"2 kg 至 20 kg","cmc":"1,4.10⁻⁵"},{"name":"M1 级砝码","range":"20 kg 至 1000 kg","cmc":"5,0.10⁻⁵"}],"parameters_cs":[{"name":"Závaží třídy E2","range":"0,001 g až 2000 g","cmc":"2,7.10⁻⁶"},{"name":"Závaží třídy F2","range":"2 kg až 20 kg","cmc":"1,4.10⁻⁵"},{"name":"Závaží třídy M1","range":"20 kg až 1000 kg","cmc":"5,0.10⁻⁵"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004)","technique_en":"Reference weight loading (according to OIML R111-1:2004)","technique_zh":"用标准砝码加载（依据 OIML R111-1:2004）","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004)","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004)"],"techniques_en":["Reference weight loading (according to OIML R111-1:2004)"],"techniques_zh":["用标准砝码加载（依据 OIML R111-1:2004）"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nOdważniki klasy E2 od 0,001 g do 2000 g CMC 2,7.10⁻⁶\nOdważniki klasy F2 od 2 kg do 20 kg CMC 1,4.10⁻⁵\nOdważniki klasy M1 od 20 kg do 1000 kg CMC 5,0.10⁻⁵\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004)","reference":"KP VA1","norm_bases":["KP VA1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) Odważniki klasy E2 od 0,001 g do 2000 g CMC 2,7.10⁻⁶ Odważniki klasy F2 od 2 kg do 20 kg CMC 1,4.10⁻⁵ Odważniki klasy M1 od 20 kg do 1000 kg CMC 5,0.10⁻⁵ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) Závaží třídy E2 0,001 g až 2000 g CMC 2,7.10⁻⁶ Závaží třídy F2 2 kg až 20 kg CMC 1,4.10⁻⁵ Závaží třídy M1 20 kg až 1000 kg CMC 5,0.10⁻⁵ KP VA1 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) Odwazniki klasy E2 od 0,001 g do 2000 g CMC 2,7.10⁻⁶ Odwazniki klasy F2 od 2 kg do 20 kg CMC 1,4.10⁻⁵ Odwazniki klasy M1 od 20 kg do 1000 kg CMC 5,0.10⁻⁵ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) Zavazi tridy E2 0,001 g az 2000 g CMC 2,7.10⁻⁶ Zavazi tridy F2 2 kg az 20 kg CMC 1,4.10⁻⁵ Zavazi tridy M1 20 kg az 1000 kg CMC 5,0.10⁻⁵ KP VA1","search_en":"Non-automatic weighing instruments Calibration – mass Reference weight loading (according to OIML R111-1:2004) E2 class weight 0,001 g to 2000 g CMC 2,7.10⁻⁶ F2 class weight 2 kg to 20 kg CMC 1,4.10⁻⁵ M1 class weight 20 kg to 1000 kg CMC 5,0.10⁻⁵ KP VA1","search_zh":"非自动衡器 校准 – 质量 用标准砝码加载（依据 OIML R111-1:2004） E2 级砝码 0,001 g 至 2000 g CMC 2,7.10⁻⁶ F2 级砝码 2 kg 至 20 kg CMC 1,4.10⁻⁵ M1 级砝码 20 kg 至 1000 kg CMC 5,0.10⁻⁵ KP VA1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"49ef83d9e80018b1c0a12660","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Masa umowna odważników i ciał","test_object_en":"Conventional weight of weights and objects","test_object_zh":"砝码及物体的约定质量","test_object_cs":"Konvenční hmotnost závaží a těles","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"1 g","cmc":"0,4 mg"},{"name":"","range":"od 1 g do 2 g","cmc":"0,5 mg"},{"name":"","range":"od 2 g do 5 g","cmc":"0,6 mg"},{"name":"","range":"od 5 g do 10 g","cmc":"0,7 mg"},{"name":"","range":"od 10 g do 20 g","cmc":"0,9 mg"},{"name":"","range":"od 20 g do 50 g","cmc":"1,2 mg"},{"name":"","range":"od 50 g do 100 g","cmc":"1,9 mg"},{"name":"","range":"od 100 g do 200 g","cmc":"2,8 mg"},{"name":"","range":"od 200 g do 500 g","cmc":"5,1 mg"},{"name":"","range":"od 500 g do 1 kg","cmc":"10 mg"},{"name":"","range":"od 1 kg do 2 kg","cmc":"17 mg"},{"name":"","range":"od 2 kg do 5 kg","cmc":"31 mg"},{"name":"","range":"od 5 kg do 10 kg","cmc":"60 mg"},{"name":"","range":"od 10 kg do 20 kg","cmc":"90 mg"}],"parameters_en":[{"name":"","range":"1 g","cmc":"0,4 mg"},{"name":"","range":"1 g to 2 g","cmc":"0,5 mg"},{"name":"","range":"2 g to 5 g","cmc":"0,6 mg"},{"name":"","range":"5 g to 10 g","cmc":"0,7 mg"},{"name":"","range":"10 g to 20 g","cmc":"0,9 mg"},{"name":"","range":"20 g to 50 g","cmc":"1,2 mg"},{"name":"","range":"50 g to 100 g","cmc":"1,9 mg"},{"name":"","range":"100 g to 200 g","cmc":"2,8 mg"},{"name":"","range":"200 g to 500 g","cmc":"5,1 mg"},{"name":"","range":"500 g to 1 kg","cmc":"10 mg"},{"name":"","range":"1 kg to 2 kg","cmc":"17 mg"},{"name":"","range":"2 kg to 5 kg","cmc":"31 mg"},{"name":"","range":"5 kg to 10 kg","cmc":"60 mg"},{"name":"","range":"10 kg to 20 kg","cmc":"90 mg"}],"parameters_zh":[{"name":"","range":"1 g","cmc":"0,4 mg"},{"name":"","range":"1 g 至 2 g","cmc":"0,5 mg"},{"name":"","range":"2 g 至 5 g","cmc":"0,6 mg"},{"name":"","range":"5 g 至 10 g","cmc":"0,7 mg"},{"name":"","range":"10 g 至 20 g","cmc":"0,9 mg"},{"name":"","range":"20 g 至 50 g","cmc":"1,2 mg"},{"name":"","range":"50 g 至 100 g","cmc":"1,9 mg"},{"name":"","range":"100 g 至 200 g","cmc":"2,8 mg"},{"name":"","range":"200 g 至 500 g","cmc":"5,1 mg"},{"name":"","range":"500 g 至 1 kg","cmc":"10 mg"},{"name":"","range":"1 kg 至 2 kg","cmc":"17 mg"},{"name":"","range":"2 kg 至 5 kg","cmc":"31 mg"},{"name":"","range":"5 kg 至 10 kg","cmc":"60 mg"},{"name":"","range":"10 kg 至 20 kg","cmc":"90 mg"}],"parameters_cs":[{"name":"","range":"1 g","cmc":"0,4 mg"},{"name":"","range":"1 g až 2 g","cmc":"0,5 mg"},{"name":"","range":"2 g až 5 g","cmc":"0,6 mg"},{"name":"","range":"5 g až 10 g","cmc":"0,7 mg"},{"name":"","range":"10 g až 20 g","cmc":"0,9 mg"},{"name":"","range":"20 g až 50 g","cmc":"1,2 mg"},{"name":"","range":"50 g až 100 g","cmc":"1,9 mg"},{"name":"","range":"100 g až 200 g","cmc":"2,8 mg"},{"name":"","range":"200 g až 500 g","cmc":"5,1 mg"},{"name":"","range":"500 g až 1 kg","cmc":"10 mg"},{"name":"","range":"1 kg až 2 kg","cmc":"17 mg"},{"name":"","range":"2 kg až 5 kg","cmc":"31 mg"},{"name":"","range":"5 kg až 10 kg","cmc":"60 mg"},{"name":"","range":"10 kg až 20 kg","cmc":"90 mg"}],"technique":"Porównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych","technique_en":"Comparison with a reference weight (according to OIML R111-1:2004) on the standard scales","technique_zh":"在标准天平上与标准砝码比较（依据 OIML R111-1:2004）","technique_cs":"Porovnání s etalonovým závažím (dle OIML R111-1:2004) na etalonových vahách","techniques":["Porównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych"],"techniques_en":["Comparison with a reference weight (according to OIML R111-1:2004) on the standard scales"],"techniques_zh":["在标准天平上与标准砝码比较（依据 OIML R111-1:2004）"],"techniques_cs":["Porovnání s etalonovým závažím (dle OIML R111-1:2004) na etalonových vahách"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\n1 g CMC 0,4 mg\nod 1 g do 2 g CMC 0,5 mg\nod 2 g do 5 g CMC 0,6 mg\nod 5 g do 10 g CMC 0,7 mg\nod 10 g do 20 g CMC 0,9 mg\nod 20 g do 50 g CMC 1,2 mg\nod 50 g do 100 g CMC 1,9 mg\nod 100 g do 200 g CMC 2,8 mg\nod 200 g do 500 g CMC 5,1 mg\nod 500 g do 1 kg CMC 10 mg\nod 1 kg do 2 kg CMC 17 mg\nod 2 kg do 5 kg CMC 31 mg\nod 5 kg do 10 kg CMC 60 mg\nod 10 kg do 20 kg CMC 90 mg\nPorównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych","reference":"KP VA2","norm_bases":["KP VA2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Masa umowna odważników i ciał Wzorcowanie – masa Porównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych 1 g CMC 0,4 mg od 1 g do 2 g CMC 0,5 mg od 2 g do 5 g CMC 0,6 mg od 5 g do 10 g CMC 0,7 mg od 10 g do 20 g CMC 0,9 mg od 20 g do 50 g CMC 1,2 mg od 50 g do 100 g CMC 1,9 mg od 100 g do 200 g CMC 2,8 mg od 200 g do 500 g CMC 5,1 mg od 500 g do 1 kg CMC 10 mg od 1 kg do 2 kg CMC 17 mg od 2 kg do 5 kg CMC 31 mg od 5 kg do 10 kg CMC 60 mg od 10 kg do 20 kg CMC 90 mg Konvenční hmotnost závaží a těles Kalibrace – hmotnost Porovnání s etalonovým závažím (dle OIML R111-1:2004) na etalonových vahách 1 g CMC 0,4 mg 1 g až 2 g CMC 0,5 mg 2 g až 5 g CMC 0,6 mg 5 g až 10 g CMC 0,7 mg 10 g až 20 g CMC 0,9 mg 20 g až 50 g CMC 1,2 mg 50 g až 100 g CMC 1,9 mg 100 g až 200 g CMC 2,8 mg 200 g až 500 g CMC 5,1 mg 500 g až 1 kg CMC 10 mg 1 kg až 2 kg CMC 17 mg 2 kg až 5 kg CMC 31 mg 5 kg až 10 kg CMC 60 mg 10 kg až 20 kg CMC 90 mg KP VA2 Masa umowna odwaznikow i cial Wzorcowanie – masa Porownanie z odwaznikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych 1 g CMC 0,4 mg od 1 g do 2 g CMC 0,5 mg od 2 g do 5 g CMC 0,6 mg od 5 g do 10 g CMC 0,7 mg od 10 g do 20 g CMC 0,9 mg od 20 g do 50 g CMC 1,2 mg od 50 g do 100 g CMC 1,9 mg od 100 g do 200 g CMC 2,8 mg od 200 g do 500 g CMC 5,1 mg od 500 g do 1 kg CMC 10 mg od 1 kg do 2 kg CMC 17 mg od 2 kg do 5 kg CMC 31 mg od 5 kg do 10 kg CMC 60 mg od 10 kg do 20 kg CMC 90 mg Konvencni hmotnost zavazi a teles Kalibrace – hmotnost Porovnani s etalonovym zavazim (dle OIML R111-1:2004) na etalonovych vahach 1 g CMC 0,4 mg 1 g az 2 g CMC 0,5 mg 2 g az 5 g CMC 0,6 mg 5 g az 10 g CMC 0,7 mg 10 g az 20 g CMC 0,9 mg 20 g az 50 g CMC 1,2 mg 50 g az 100 g CMC 1,9 mg 100 g az 200 g CMC 2,8 mg 200 g az 500 g CMC 5,1 mg 500 g az 1 kg CMC 10 mg 1 kg az 2 kg CMC 17 mg 2 kg az 5 kg CMC 31 mg 5 kg az 10 kg CMC 60 mg 10 kg az 20 kg CMC 90 mg KP VA2","search_en":"Conventional weight of weights and objects Calibration – mass Comparison with a reference weight (according to OIML R111-1:2004) on the standard scales 1 g CMC 0,4 mg 1 g to 2 g CMC 0,5 mg 2 g to 5 g CMC 0,6 mg 5 g to 10 g CMC 0,7 mg 10 g to 20 g CMC 0,9 mg 20 g to 50 g CMC 1,2 mg 50 g to 100 g CMC 1,9 mg 100 g to 200 g CMC 2,8 mg 200 g to 500 g CMC 5,1 mg 500 g to 1 kg CMC 10 mg 1 kg to 2 kg CMC 17 mg 2 kg to 5 kg CMC 31 mg 5 kg to 10 kg CMC 60 mg 10 kg to 20 kg CMC 90 mg KP VA2","search_zh":"砝码及物体的约定质量 校准 – 质量 在标准天平上与标准砝码比较（依据 OIML R111-1:2004） 1 g CMC 0,4 mg 1 g 至 2 g CMC 0,5 mg 2 g 至 5 g CMC 0,6 mg 5 g 至 10 g CMC 0,7 mg 10 g 至 20 g CMC 0,9 mg 20 g 至 50 g CMC 1,2 mg 50 g 至 100 g CMC 1,9 mg 100 g 至 200 g CMC 2,8 mg 200 g 至 500 g CMC 5,1 mg 500 g 至 1 kg CMC 10 mg 1 kg 至 2 kg CMC 17 mg 2 kg 至 5 kg CMC 31 mg 5 kg 至 10 kg CMC 60 mg 10 kg 至 20 kg CMC 90 mg KP VA2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"470ed594bd92da2d86b509d1","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru prędkości obrotowej","test_object_en":"Revolution meters","test_object_zh":"转速测量仪","test_object_cs":"Měřidla otáček","methodology":"Wzorcowanie – prędkość obrotowa","methodology_en":"Calibration – rotational speed","methodology_zh":"校准 – 转速","methodology_cs":"Kalibrace – otáčky","parameters":[{"name":"","range":"od 30 min⁻¹ do 40000 min⁻¹","cmc":"1,1 %"}],"parameters_en":[{"name":"","range":"30 min⁻¹ to 40000 min⁻¹","cmc":"1,1 %"}],"parameters_zh":[{"name":"","range":"30 min⁻¹ 至 40000 min⁻¹","cmc":"1,1 %"}],"parameters_cs":[{"name":"","range":"30 min⁻¹ až 40000 min⁻¹","cmc":"1,1 %"}],"technique":"Pomiar bezpośredni na generatorze prędkości obrotowej","technique_en":"Direct measurement by a revolution generator","technique_zh":"在转速发生器上直接测量","technique_cs":"Přímé měření na generátoru otáček","techniques":["Pomiar bezpośredni na generatorze prędkości obrotowej"],"techniques_en":["Direct measurement by a revolution generator"],"techniques_zh":["在转速发生器上直接测量"],"techniques_cs":["Přímé měření na generátoru otáček"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – prędkość obrotowa\nod 30 min⁻¹ do 40000 min⁻¹ CMC 1,1 %\nPomiar bezpośredni na generatorze prędkości obrotowej","reference":"KP OT1","norm_bases":["KP OT1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: prędkość obrotowa","regulatory_area_en":"CMC for the field of measured quantity: Rotational speed","regulatory_area_zh":"被测量领域的CMC：转速","regulatory_area_cs":"CMC pro obor měřené veličiny: Otáčky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru prędkości obrotowej Wzorcowanie – prędkość obrotowa Pomiar bezpośredni na generatorze prędkości obrotowej od 30 min⁻¹ do 40000 min⁻¹ CMC 1,1 % Měřidla otáček Kalibrace – otáčky Přímé měření na generátoru otáček 30 min⁻¹ až 40000 min⁻¹ CMC 1,1 % KP OT1 Przyrzady do pomiaru predkosci obrotowej Wzorcowanie – predkosc obrotowa Pomiar bezposredni na generatorze predkosci obrotowej od 30 min⁻¹ do 40000 min⁻¹ CMC 1,1 % Meridla otacek Kalibrace – otacky Prime mereni na generatoru otacek 30 min⁻¹ az 40000 min⁻¹ CMC 1,1 % KP OT1","search_en":"Revolution meters Calibration – rotational speed Direct measurement by a revolution generator 30 min⁻¹ to 40000 min⁻¹ CMC 1,1 % KP OT1","search_zh":"转速测量仪 校准 – 转速 在转速发生器上直接测量 30 min⁻¹ 至 40000 min⁻¹ CMC 1,1 % KP OT1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"061af171924c30e1c53987fb","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Twardość / płytki wzorcowe twardości i próbki","test_object_en":"Hardness / Hardness plates and samples","test_object_zh":"硬度 / 硬度块和试样","test_object_cs":"Tvrdost / Tvrdoměrné destičky a vzorky","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"Rockwell","range":"od 70 HRA do 85 HRA","cmc":"0,40 HRA"},{"name":"Rockwell","range":"od 60 HRB do 100 HRB","cmc":"0,40 HRB"},{"name":"Rockwell","range":"od 20 HRC do 70 HRC","cmc":"0,40 HRC"}],"parameters_en":[{"name":"Rockwell","range":"70 HRA to 85 HRA","cmc":"0,40 HRA"},{"name":"Rockwell","range":"60 HRB to 100 HRB","cmc":"0,40 HRB"},{"name":"Rockwell","range":"20 HRC to 70 HRC","cmc":"0,40 HRC"}],"parameters_zh":[{"name":"洛氏","range":"70 HRA 至 85 HRA","cmc":"0,40 HRA"},{"name":"洛氏","range":"60 HRB 至 100 HRB","cmc":"0,40 HRB"},{"name":"洛氏","range":"20 HRC 至 70 HRC","cmc":"0,40 HRC"}],"parameters_cs":[{"name":"Rockwell","range":"70 HRA až 85 HRA","cmc":"0,40 HRA"},{"name":"Rockwell","range":"60 HRB až 100 HRB","cmc":"0,40 HRB"},{"name":"Rockwell","range":"20 HRC až 70 HRC","cmc":"0,40 HRC"}],"technique":"Pomiar bezpośredni","technique_en":"Direct measurement","technique_zh":"直接测量","technique_cs":"Přímé měření","techniques":["Pomiar bezpośredni"],"techniques_en":["Direct measurement"],"techniques_zh":["直接测量"],"techniques_cs":["Přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nZakres:\nRockwell od 70 HRA do 85 HRA CMC 0,40 HRA\nRockwell od 60 HRB do 100 HRB CMC 0,40 HRB\nRockwell od 20 HRC do 70 HRC CMC 0,40 HRC\nPomiar bezpośredni","reference":"KP TV1","norm_bases":["KP TV1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Twardość / płytki wzorcowe twardości i próbki Wzorcowanie – siła, badania mechaniczne Pomiar bezpośredni Rockwell od 70 HRA do 85 HRA CMC 0,40 HRA Rockwell od 60 HRB do 100 HRB CMC 0,40 HRB Rockwell od 20 HRC do 70 HRC CMC 0,40 HRC Tvrdost / Tvrdoměrné destičky a vzorky Kalibrace – síla, mechanické zkoušky Přímé měření Rockwell 70 HRA až 85 HRA CMC 0,40 HRA Rockwell 60 HRB až 100 HRB CMC 0,40 HRB Rockwell 20 HRC až 70 HRC CMC 0,40 HRC KP TV1 Twardosc / plytki wzorcowe twardosci i probki Wzorcowanie – sila, badania mechaniczne Pomiar bezposredni Rockwell od 70 HRA do 85 HRA CMC 0,40 HRA Rockwell od 60 HRB do 100 HRB CMC 0,40 HRB Rockwell od 20 HRC do 70 HRC CMC 0,40 HRC Tvrdost / Tvrdomerne desticky a vzorky Kalibrace – sila, mechanicke zkousky Prime mereni Rockwell 70 HRA az 85 HRA CMC 0,40 HRA Rockwell 60 HRB az 100 HRB CMC 0,40 HRB Rockwell 20 HRC az 70 HRC CMC 0,40 HRC KP TV1","search_en":"Hardness / Hardness plates and samples Calibration – force, mechanical tests Direct measurement Rockwell 70 HRA to 85 HRA CMC 0,40 HRA Rockwell 60 HRB to 100 HRB CMC 0,40 HRB Rockwell 20 HRC to 70 HRC CMC 0,40 HRC KP TV1","search_zh":"硬度 / 硬度块和试样 校准 – 力、机械试验 直接测量 洛氏 70 HRA 至 85 HRA CMC 0,40 HRA 洛氏 60 HRB 至 100 HRB CMC 0,40 HRB 洛氏 20 HRC 至 70 HRC CMC 0,40 HRC KP TV1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e7c812abee592bf8ff11a217","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Twardość / płytki wzorcowe twardości","test_object_en":"Hardness / Hardness plates","test_object_zh":"硬度 / 硬度块","test_object_cs":"Tvrdost / Tvrdoměrné destičky","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"Shore A","range":"od 0 ShA do 100 ShA","cmc":"2,0 ShA"},{"name":"Shore D","range":"od 0 ShD do 100 ShD","cmc":"2,0 ShD"},{"name":"Brinell","range":"od 8 HBW do 650 HBW","cmc":"1,0 %"},{"name":"Vickers; HV2 do HV50","range":"od 10 HV do 2900 HV","cmc":"1,0 %"}],"parameters_en":[{"name":"Shore A","range":"0 ShA to 100 ShA","cmc":"2,0 ShA"},{"name":"Shore D","range":"0 ShD to 100 ShD","cmc":"2,0 ShD"},{"name":"Brinell","range":"8 HBW to 650 HBW","cmc":"1,0 %"},{"name":"Vickers; HV2 to HV50","range":"10 HV to 2900 HV","cmc":"1,0 %"}],"parameters_zh":[{"name":"邵氏 A","range":"0 ShA 至 100 ShA","cmc":"2,0 ShA"},{"name":"邵氏 D","range":"0 ShD 至 100 ShD","cmc":"2,0 ShD"},{"name":"布氏","range":"8 HBW 至 650 HBW","cmc":"1,0 %"},{"name":"维氏；HV2 至 HV50","range":"10 HV 至 2900 HV","cmc":"1,0 %"}],"parameters_cs":[{"name":"Shore A","range":"0 ShA až 100 ShA","cmc":"2,0 ShA"},{"name":"Shore D","range":"0 ShD až 100 ShD","cmc":"2,0 ShD"},{"name":"Brinell","range":"8 HBW až 650 HBW","cmc":"1,0 %"},{"name":"Vickers; HV2 až HV50","range":"10 HV až 2900 HV","cmc":"1,0 %"}],"technique":"Pomiar bezpośredni","technique_en":"Direct measurement","technique_zh":"直接测量","technique_cs":"Přímé měření","techniques":["Pomiar bezpośredni"],"techniques_en":["Direct measurement"],"techniques_zh":["直接测量"],"techniques_cs":["Přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nZakres:\nShore A od 0 ShA do 100 ShA CMC 2,0 ShA\nShore D od 0 ShD do 100 ShD CMC 2,0 ShD\nBrinell od 8 HBW do 650 HBW CMC 1,0 %\nVickers; HV2 do HV50 od 10 HV do 2900 HV CMC 1,0 %\nPomiar bezpośredni","reference":"KP TV1","norm_bases":["KP TV1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Twardość / płytki wzorcowe twardości Wzorcowanie – siła, badania mechaniczne Pomiar bezpośredni Shore A od 0 ShA do 100 ShA CMC 2,0 ShA Shore D od 0 ShD do 100 ShD CMC 2,0 ShD Brinell od 8 HBW do 650 HBW CMC 1,0 % Vickers; HV2 do HV50 od 10 HV do 2900 HV CMC 1,0 % Tvrdost / Tvrdoměrné destičky Kalibrace – síla, mechanické zkoušky Přímé měření Shore A 0 ShA až 100 ShA CMC 2,0 ShA Shore D 0 ShD až 100 ShD CMC 2,0 ShD Brinell 8 HBW až 650 HBW CMC 1,0 % Vickers; HV2 až HV50 10 HV až 2900 HV CMC 1,0 % KP TV1 Twardosc / plytki wzorcowe twardosci Wzorcowanie – sila, badania mechaniczne Pomiar bezposredni Shore A od 0 ShA do 100 ShA CMC 2,0 ShA Shore D od 0 ShD do 100 ShD CMC 2,0 ShD Brinell od 8 HBW do 650 HBW CMC 1,0 % Vickers; HV2 do HV50 od 10 HV do 2900 HV CMC 1,0 % Tvrdost / Tvrdomerne desticky Kalibrace – sila, mechanicke zkousky Prime mereni Shore A 0 ShA az 100 ShA CMC 2,0 ShA Shore D 0 ShD az 100 ShD CMC 2,0 ShD Brinell 8 HBW az 650 HBW CMC 1,0 % Vickers; HV2 az HV50 10 HV az 2900 HV CMC 1,0 % KP TV1","search_en":"Hardness / Hardness plates Calibration – force, mechanical tests Direct measurement Shore A 0 ShA to 100 ShA CMC 2,0 ShA Shore D 0 ShD to 100 ShD CMC 2,0 ShD Brinell 8 HBW to 650 HBW CMC 1,0 % Vickers; HV2 to HV50 10 HV to 2900 HV CMC 1,0 % KP TV1","search_zh":"硬度 / 硬度块 校准 – 力、机械试验 直接测量 邵氏 A 0 ShA 至 100 ShA CMC 2,0 ShA 邵氏 D 0 ShD 至 100 ShD CMC 2,0 ShD 布氏 8 HBW 至 650 HBW CMC 1,0 % 维氏；HV2 至 HV50 10 HV 至 2900 HV CMC 1,0 % KP TV1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d1054a92df4cb78c80aff0d6","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Twardość / twardościomierze do metali","test_object_en":"Hardness / Hardness meters for metals","test_object_zh":"硬度 / 金属硬度计","test_object_cs":"Tvrdost / Tvrdoměry na kovy","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"Rockwell","range":"od 70 HRA do 85 HRA","cmc":"0,50 HRA"},{"name":"Rockwell","range":"od 60 HRB do 100 HRB","cmc":"0,50 HRB"},{"name":"Rockwell","range":"od 20 HRC do 70 HRC","cmc":"0,50 HRC"},{"name":"Vickers","range":"od 10 HV do 2000 HV","cmc":"0,50 %"},{"name":"Brinell","range":"od 10 HBW do 650 HBW","cmc":"0,50 %"}],"parameters_en":[{"name":"Rockwell","range":"70 HRA to 85 HRA","cmc":"0,50 HRA"},{"name":"Rockwell","range":"60 HRB to 100 HRB","cmc":"0,50 HRB"},{"name":"Rockwell","range":"20 HRC to 70 HRC","cmc":"0,50 HRC"},{"name":"Vickers","range":"10 HV to 2000 HV","cmc":"0,50 %"},{"name":"Brinell","range":"10 HBW to 650 HBW","cmc":"0,50 %"}],"parameters_zh":[{"name":"洛氏","range":"70 HRA 至 85 HRA","cmc":"0,50 HRA"},{"name":"洛氏","range":"60 HRB 至 100 HRB","cmc":"0,50 HRB"},{"name":"洛氏","range":"20 HRC 至 70 HRC","cmc":"0,50 HRC"},{"name":"维氏","range":"10 HV 至 2000 HV","cmc":"0,50 %"},{"name":"布氏","range":"10 HBW 至 650 HBW","cmc":"0,50 %"}],"parameters_cs":[{"name":"Rockwell","range":"70 HRA až 85 HRA","cmc":"0,50 HRA"},{"name":"Rockwell","range":"60 HRB až 100 HRB","cmc":"0,50 HRB"},{"name":"Rockwell","range":"20 HRC až 70 HRC","cmc":"0,50 HRC"},{"name":"Vickers","range":"10 HV až 2000 HV","cmc":"0,50 %"},{"name":"Brinell","range":"10 HBW až 650 HBW","cmc":"0,50 %"}],"technique":"Pomiar bezpośredni za pomocą wzorcowych płytek twardości","technique_en":"Direct measurement using reference hardness plates","technique_zh":"用标准硬度块直接测量","technique_cs":"Přímé měření pomocí etalonových tvrdoměrných destiček","techniques":["Pomiar bezpośredni za pomocą wzorcowych płytek twardości"],"techniques_en":["Direct measurement using reference hardness plates"],"techniques_zh":["用标准硬度块直接测量"],"techniques_cs":["Přímé měření pomocí etalonových tvrdoměrných destiček"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nZakres:\nRockwell od 70 HRA do 85 HRA CMC 0,50 HRA\nRockwell od 60 HRB do 100 HRB CMC 0,50 HRB\nRockwell od 20 HRC do 70 HRC CMC 0,50 HRC\nVickers od 10 HV do 2000 HV CMC 0,50 %\nBrinell od 10 HBW do 650 HBW CMC 0,50 %\nPomiar bezpośredni za pomocą wzorcowych płytek twardości","reference":"KP TV1","norm_bases":["KP TV1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Twardość / twardościomierze do metali Wzorcowanie – siła, badania mechaniczne Pomiar bezpośredni za pomocą wzorcowych płytek twardości Rockwell od 70 HRA do 85 HRA CMC 0,50 HRA Rockwell od 60 HRB do 100 HRB CMC 0,50 HRB Rockwell od 20 HRC do 70 HRC CMC 0,50 HRC Vickers od 10 HV do 2000 HV CMC 0,50 % Brinell od 10 HBW do 650 HBW CMC 0,50 % Tvrdost / Tvrdoměry na kovy Kalibrace – síla, mechanické zkoušky Přímé měření pomocí etalonových tvrdoměrných destiček Rockwell 70 HRA až 85 HRA CMC 0,50 HRA Rockwell 60 HRB až 100 HRB CMC 0,50 HRB Rockwell 20 HRC až 70 HRC CMC 0,50 HRC Vickers 10 HV až 2000 HV CMC 0,50 % Brinell 10 HBW až 650 HBW CMC 0,50 % KP TV1 Twardosc / twardosciomierze do metali Wzorcowanie – sila, badania mechaniczne Pomiar bezposredni za pomoca wzorcowych plytek twardosci Rockwell od 70 HRA do 85 HRA CMC 0,50 HRA Rockwell od 60 HRB do 100 HRB CMC 0,50 HRB Rockwell od 20 HRC do 70 HRC CMC 0,50 HRC Vickers od 10 HV do 2000 HV CMC 0,50 % Brinell od 10 HBW do 650 HBW CMC 0,50 % Tvrdost / Tvrdomery na kovy Kalibrace – sila, mechanicke zkousky Prime mereni pomoci etalonovych tvrdomernych desticek Rockwell 70 HRA az 85 HRA CMC 0,50 HRA Rockwell 60 HRB az 100 HRB CMC 0,50 HRB Rockwell 20 HRC az 70 HRC CMC 0,50 HRC Vickers 10 HV az 2000 HV CMC 0,50 % Brinell 10 HBW az 650 HBW CMC 0,50 % KP TV1","search_en":"Hardness / Hardness meters for metals Calibration – force, mechanical tests Direct measurement using reference hardness plates Rockwell 70 HRA to 85 HRA CMC 0,50 HRA Rockwell 60 HRB to 100 HRB CMC 0,50 HRB Rockwell 20 HRC to 70 HRC CMC 0,50 HRC Vickers 10 HV to 2000 HV CMC 0,50 % Brinell 10 HBW to 650 HBW CMC 0,50 % KP TV1","search_zh":"硬度 / 金属硬度计 校准 – 力、机械试验 用标准硬度块直接测量 洛氏 70 HRA 至 85 HRA CMC 0,50 HRA 洛氏 60 HRB 至 100 HRB CMC 0,50 HRB 洛氏 20 HRC 至 70 HRC CMC 0,50 HRC 维氏 10 HV 至 2000 HV CMC 0,50 % 布氏 10 HBW 至 650 HBW CMC 0,50 % KP TV1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f0e710c12b36b85e3538cfe","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Twardość / twardościomierze Shore typu A, D, E, C","test_object_en":"Hardness / Shore hardness meters, type A,D,E,C","test_object_zh":"硬度 / A、D、E、C 型邵氏硬度计","test_object_cs":"Tvrdost / Tvrdoměry Shore typu A, D, E, C","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"","range":"od 1 Sh do 100 Sh","cmc":"0,50 Sh"}],"parameters_en":[{"name":"","range":"1 Sh to 100 Sh","cmc":"0,50 Sh"}],"parameters_zh":[{"name":"","range":"1 Sh 至 100 Sh","cmc":"0,50 Sh"}],"parameters_cs":[{"name":"","range":"1 Sh až 100 Sh","cmc":"0,50 Sh"}],"technique":"Pomiar bezpośredni za pomocą wzorcowych płytek twardości","technique_en":"Direct measurement using reference hardness plates","technique_zh":"用标准硬度块直接测量","technique_cs":"Přímé měření pomocí etalonových tvrdoměrných destiček","techniques":["Pomiar bezpośredni za pomocą wzorcowych płytek twardości"],"techniques_en":["Direct measurement using reference hardness plates"],"techniques_zh":["用标准硬度块直接测量"],"techniques_cs":["Přímé měření pomocí etalonových tvrdoměrných destiček"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nod 1 Sh do 100 Sh CMC 0,50 Sh\nPomiar bezpośredni za pomocą wzorcowych płytek twardości","reference":"KP TV1","norm_bases":["KP TV1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Twardość / twardościomierze Shore typu A, D, E, C Wzorcowanie – siła, badania mechaniczne Pomiar bezpośredni za pomocą wzorcowych płytek twardości od 1 Sh do 100 Sh CMC 0,50 Sh Tvrdost / Tvrdoměry Shore typu A, D, E, C Kalibrace – síla, mechanické zkoušky Přímé měření pomocí etalonových tvrdoměrných destiček 1 Sh až 100 Sh CMC 0,50 Sh KP TV1 Twardosc / twardosciomierze Shore typu A, D, E, C Wzorcowanie – sila, badania mechaniczne Pomiar bezposredni za pomoca wzorcowych plytek twardosci od 1 Sh do 100 Sh CMC 0,50 Sh Tvrdost / Tvrdomery Shore typu A, D, E, C Kalibrace – sila, mechanicke zkousky Prime mereni pomoci etalonovych tvrdomernych desticek 1 Sh az 100 Sh CMC 0,50 Sh KP TV1","search_en":"Hardness / Shore hardness meters, type A,D,E,C Calibration – force, mechanical tests Direct measurement using reference hardness plates 1 Sh to 100 Sh CMC 0,50 Sh KP TV1","search_zh":"硬度 / A、D、E、C 型邵氏硬度计 校准 – 力、机械试验 用标准硬度块直接测量 1 Sh 至 100 Sh CMC 0,50 Sh KP TV1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"07481c037a3dd645d95f005c","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"3","test_object":"Moment siły / klucze dynamometryczne","test_object_en":"Torque / Torque wrenches","test_object_zh":"扭矩 / 扭矩扳手","test_object_cs":"Moment síly / Momentové klíče","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"","range":"od 0,1 Nm do 1100 Nm","cmc":"0,65 %"},{"name":"","range":"od 1100 Nm do 3000 Nm","cmc":"0,90 %"}],"parameters_en":[{"name":"","range":"0,1 Nm to 1100 Nm","cmc":"0,65 %"},{"name":"","range":"1100 Nm to 3000 Nm","cmc":"0,90 %"}],"parameters_zh":[{"name":"","range":"0,1 Nm 至 1100 Nm","cmc":"0,65 %"},{"name":"","range":"1100 Nm 至 3000 Nm","cmc":"0,90 %"}],"parameters_cs":[{"name":"","range":"0,1 Nm až 1100 Nm","cmc":"0,65 %"},{"name":"","range":"1100 Nm až 3000 Nm","cmc":"0,90 %"}],"technique":"Pomiar porównawczy z wzorcowym przetwornikiem momentu obrotowego","technique_en":"Comparative measurement by a reference torque sensor","technique_zh":"用标准扭矩传感器比较测量","technique_cs":"Porovnávací měření s etalonovým snímačem krouticího momentu","techniques":["Pomiar porównawczy z wzorcowym przetwornikiem momentu obrotowego"],"techniques_en":["Comparative measurement by a reference torque sensor"],"techniques_zh":["用标准扭矩传感器比较测量"],"techniques_cs":["Porovnávací měření s etalonovým snímačem krouticího momentu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nZakres:\nod 0,1 Nm do 1100 Nm CMC 0,65 %\nod 1100 Nm do 3000 Nm CMC 0,90 %\nPomiar porównawczy z wzorcowym przetwornikiem momentu obrotowego","reference":"KP S1","norm_bases":["KP S1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moment siły / klucze dynamometryczne Wzorcowanie – siła, badania mechaniczne Pomiar porównawczy z wzorcowym przetwornikiem momentu obrotowego od 0,1 Nm do 1100 Nm CMC 0,65 % od 1100 Nm do 3000 Nm CMC 0,90 % Moment síly / Momentové klíče Kalibrace – síla, mechanické zkoušky Porovnávací měření s etalonovým snímačem krouticího momentu 0,1 Nm až 1100 Nm CMC 0,65 % 1100 Nm až 3000 Nm CMC 0,90 % KP S1 Moment sily / klucze dynamometryczne Wzorcowanie – sila, badania mechaniczne Pomiar porownawczy z wzorcowym przetwornikiem momentu obrotowego od 0,1 Nm do 1100 Nm CMC 0,65 % od 1100 Nm do 3000 Nm CMC 0,90 % Moment sily / Momentove klice Kalibrace – sila, mechanicke zkousky Porovnavaci mereni s etalonovym snimacem krouticiho momentu 0,1 Nm az 1100 Nm CMC 0,65 % 1100 Nm az 3000 Nm CMC 0,90 % KP S1","search_en":"Torque / Torque wrenches Calibration – force, mechanical tests Comparative measurement by a reference torque sensor 0,1 Nm to 1100 Nm CMC 0,65 % 1100 Nm to 3000 Nm CMC 0,90 % KP S1","search_zh":"扭矩 / 扭矩扳手 校准 – 力、机械试验 用标准扭矩传感器比较测量 0,1 Nm 至 1100 Nm CMC 0,65 % 1100 Nm 至 3000 Nm CMC 0,90 % KP S1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4a0747c010664b622e448029","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"3","test_object":"Moment siły / urządzenia do pomiaru momentu siły, dokręcarki dynamometryczne, przetworniki momentu siły","test_object_en":"Torque / Torque measuring devices, torque drivers, torque sensors","test_object_zh":"扭矩 / 扭矩测量装置、扭矩拧紧器、扭矩传感器","test_object_cs":"Moment síly / Zařízení pro měření momentu síly, momentové utahovačky, snímače momentu síly","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"","range":"od 0,1 Nm do 500 Nm","cmc":"0,40 %"},{"name":"","range":"od 500 Nm do 2000 Nm","cmc":"1,05 %"}],"parameters_en":[{"name":"","range":"0,1 Nm to 500 Nm","cmc":"0,40 %"},{"name":"","range":"500 Nm to 2000 Nm","cmc":"1,05 %"}],"parameters_zh":[{"name":"","range":"0,1 Nm 至 500 Nm","cmc":"0,40 %"},{"name":"","range":"500 Nm 至 2000 Nm","cmc":"1,05 %"}],"parameters_cs":[{"name":"","range":"0,1 Nm až 500 Nm","cmc":"0,40 %"},{"name":"","range":"500 Nm až 2000 Nm","cmc":"1,05 %"}],"technique":"Pomiar porównawczy z wzorcowym przetwornikiem momentu obrotowego","technique_en":"Comparative measurement by a reference torque sensor","technique_zh":"用标准扭矩传感器比较测量","technique_cs":"Porovnávací měření s etalonovým snímačem krouticího momentu","techniques":["Pomiar porównawczy z wzorcowym przetwornikiem momentu obrotowego"],"techniques_en":["Comparative measurement by a reference torque sensor"],"techniques_zh":["用标准扭矩传感器比较测量"],"techniques_cs":["Porovnávací měření s etalonovým snímačem krouticího momentu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nZakres:\nod 0,1 Nm do 500 Nm CMC 0,40 %\nod 500 Nm do 2000 Nm CMC 1,05 %\nPomiar porównawczy z wzorcowym przetwornikiem momentu obrotowego","reference":"KP S1","norm_bases":["KP S1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moment siły / urządzenia do pomiaru momentu siły, dokręcarki dynamometryczne, przetworniki momentu siły Wzorcowanie – siła, badania mechaniczne Pomiar porównawczy z wzorcowym przetwornikiem momentu obrotowego od 0,1 Nm do 500 Nm CMC 0,40 % od 500 Nm do 2000 Nm CMC 1,05 % Moment síly / Zařízení pro měření momentu síly, momentové utahovačky, snímače momentu síly Kalibrace – síla, mechanické zkoušky Porovnávací měření s etalonovým snímačem krouticího momentu 0,1 Nm až 500 Nm CMC 0,40 % 500 Nm až 2000 Nm CMC 1,05 % KP S1 Moment sily / urzadzenia do pomiaru momentu sily, dokrecarki dynamometryczne, przetworniki momentu sily Wzorcowanie – sila, badania mechaniczne Pomiar porownawczy z wzorcowym przetwornikiem momentu obrotowego od 0,1 Nm do 500 Nm CMC 0,40 % od 500 Nm do 2000 Nm CMC 1,05 % Moment sily / Zarizeni pro mereni momentu sily, momentove utahovacky, snimace momentu sily Kalibrace – sila, mechanicke zkousky Porovnavaci mereni s etalonovym snimacem krouticiho momentu 0,1 Nm az 500 Nm CMC 0,40 % 500 Nm az 2000 Nm CMC 1,05 % KP S1","search_en":"Torque / Torque measuring devices, torque drivers, torque sensors Calibration – force, mechanical tests Comparative measurement by a reference torque sensor 0,1 Nm to 500 Nm CMC 0,40 % 500 Nm to 2000 Nm CMC 1,05 % KP S1","search_zh":"扭矩 / 扭矩测量装置、扭矩拧紧器、扭矩传感器 校准 – 力、机械试验 用标准扭矩传感器比较测量 0,1 Nm 至 500 Nm CMC 0,40 % 500 Nm 至 2000 Nm CMC 1,05 % KP S1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bb842312562df415ca6f54b8","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"4","test_object":"Moment siły / siłomierze i przetworniki tensometryczne","test_object_en":"Moment of force / Force meters and extensometric sensors","test_object_zh":"扭矩 / 测力计和应变式传感器","test_object_cs":"Moment síly / Siloměry a tenzometrické snímače","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"","range":"od 0,001 N do 5 kN","cmc":"0,20 %"},{"name":"","range":"od 5 kN do 30 kN","cmc":"0,30 %"}],"parameters_en":[{"name":"","range":"0,001 N to 5 kN","cmc":"0,20 %"},{"name":"","range":"5 kN to 30 kN","cmc":"0,30 %"}],"parameters_zh":[{"name":"","range":"0,001 N 至 5 kN","cmc":"0,20 %"},{"name":"","range":"5 kN 至 30 kN","cmc":"0,30 %"}],"parameters_cs":[{"name":"","range":"0,001 N až 5 kN","cmc":"0,20 %"},{"name":"","range":"5 kN až 30 kN","cmc":"0,30 %"}],"technique":"Pomiar porównawczy z wzorcowym przetwornikiem siły","technique_en":"Comparative measurement by a reference force sensor","technique_zh":"用标准力传感器比较测量","technique_cs":"Porovnávací měření s etalonovým snímačem síly","techniques":["Pomiar porównawczy z wzorcowym przetwornikiem siły"],"techniques_en":["Comparative measurement by a reference force sensor"],"techniques_zh":["用标准力传感器比较测量"],"techniques_cs":["Porovnávací měření s etalonovým snímačem síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nZakres:\nod 0,001 N do 5 kN CMC 0,20 %\nod 5 kN do 30 kN CMC 0,30 %\nPomiar porównawczy z wzorcowym przetwornikiem siły","reference":"KP S2","norm_bases":["KP S2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moment siły / siłomierze i przetworniki tensometryczne Wzorcowanie – siła, badania mechaniczne Pomiar porównawczy z wzorcowym przetwornikiem siły od 0,001 N do 5 kN CMC 0,20 % od 5 kN do 30 kN CMC 0,30 % Moment síly / Siloměry a tenzometrické snímače Kalibrace – síla, mechanické zkoušky Porovnávací měření s etalonovým snímačem síly 0,001 N až 5 kN CMC 0,20 % 5 kN až 30 kN CMC 0,30 % KP S2 Moment sily / silomierze i przetworniki tensometryczne Wzorcowanie – sila, badania mechaniczne Pomiar porownawczy z wzorcowym przetwornikiem sily od 0,001 N do 5 kN CMC 0,20 % od 5 kN do 30 kN CMC 0,30 % Moment sily / Silomery a tenzometricke snimace Kalibrace – sila, mechanicke zkousky Porovnavaci mereni s etalonovym snimacem sily 0,001 N az 5 kN CMC 0,20 % 5 kN az 30 kN CMC 0,30 % KP S2","search_en":"Moment of force / Force meters and extensometric sensors Calibration – force, mechanical tests Comparative measurement by a reference force sensor 0,001 N to 5 kN CMC 0,20 % 5 kN to 30 kN CMC 0,30 % KP S2","search_zh":"扭矩 / 测力计和应变式传感器 校准 – 力、机械试验 用标准力传感器比较测量 0,001 N 至 5 kN CMC 0,20 % 5 kN 至 30 kN CMC 0,30 % KP S2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f815b4213568383b32f78a2b","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"5","test_object":"Moment siły / siłomierze i przetworniki tensometryczne","test_object_en":"Moment of force / Force meters and extensometric sensors","test_object_zh":"扭矩 / 测力计和应变式传感器","test_object_cs":"Moment síly / Siloměry a tenzometrické snímače","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"","range":"od 0,001 N do 5 kN","cmc":"0,20 %"},{"name":"","range":"od 5 kN do 20 kN","cmc":"0,30 %"}],"parameters_en":[{"name":"","range":"0,001 N to 5 kN","cmc":"0,20 %"},{"name":"","range":"5 kN to 20 kN","cmc":"0,30 %"}],"parameters_zh":[{"name":"","range":"0,001 N 至 5 kN","cmc":"0,20 %"},{"name":"","range":"5 kN 至 20 kN","cmc":"0,30 %"}],"parameters_cs":[{"name":"","range":"0,001 N až 5 kN","cmc":"0,20 %"},{"name":"","range":"5 kN až 20 kN","cmc":"0,30 %"}],"technique":"Pomiar porównawczy z wzorcowym przetwornikiem siły","technique_en":"Comparative measurement by a reference force sensor","technique_zh":"用标准力传感器比较测量","technique_cs":"Porovnávací měření s etalonovým snímačem síly","techniques":["Pomiar porównawczy z wzorcowym przetwornikiem siły"],"techniques_en":["Comparative measurement by a reference force sensor"],"techniques_zh":["用标准力传感器比较测量"],"techniques_cs":["Porovnávací měření s etalonovým snímačem síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nZakres:\nod 0,001 N do 5 kN CMC 0,20 %\nod 5 kN do 20 kN CMC 0,30 %\nPomiar porównawczy z wzorcowym przetwornikiem siły","reference":"KP S2","norm_bases":["KP S2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moment siły / siłomierze i przetworniki tensometryczne Wzorcowanie – siła, badania mechaniczne Pomiar porównawczy z wzorcowym przetwornikiem siły od 0,001 N do 5 kN CMC 0,20 % od 5 kN do 20 kN CMC 0,30 % Moment síly / Siloměry a tenzometrické snímače Kalibrace – síla, mechanické zkoušky Porovnávací měření s etalonovým snímačem síly 0,001 N až 5 kN CMC 0,20 % 5 kN až 20 kN CMC 0,30 % KP S2 Moment sily / silomierze i przetworniki tensometryczne Wzorcowanie – sila, badania mechaniczne Pomiar porownawczy z wzorcowym przetwornikiem sily od 0,001 N do 5 kN CMC 0,20 % od 5 kN do 20 kN CMC 0,30 % Moment sily / Silomery a tenzometricke snimace Kalibrace – sila, mechanicke zkousky Porovnavaci mereni s etalonovym snimacem sily 0,001 N az 5 kN CMC 0,20 % 5 kN az 20 kN CMC 0,30 % KP S2","search_en":"Moment of force / Force meters and extensometric sensors Calibration – force, mechanical tests Comparative measurement by a reference force sensor 0,001 N to 5 kN CMC 0,20 % 5 kN to 20 kN CMC 0,30 % KP S2","search_zh":"扭矩 / 测力计和应变式传感器 校准 – 力、机械试验 用标准力传感器比较测量 0,001 N 至 5 kN CMC 0,20 % 5 kN 至 20 kN CMC 0,30 % KP S2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"62d74981db1baf8c9e40159a","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste, ciśnieniomierze do opon, ciśnieniomierze elektromechaniczne (ciśnieniomierze cyfrowe, przetworniki ciśnienia z wyjściem cyfrowym)","test_object_en":"Deformation manometers, tyre pressure gauges, electromechanical pressure gauges (digital pressure gauges, pressure transducers with digital output of the measured quantity)","test_object_zh":"弹性压力表、轮胎压力表、机电式压力表（数字压力表、带数字输出的压力变送器）","test_object_cs":"Deformační tlakoměry, měřidla tlaku v pneumatikách, elektromechanické tlakoměry (číslicové tlakoměry, převodníky tlaku s digitálním výstupem měřené veličiny)","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"Gaz; Ciśnienie bezwzględne","range":"od 0 kPa do 7 MPa","cmc":"0,05 % + 100 Pa"},{"name":"Gaz; Nadciśnienie","range":"od -100 kPa do -1 kPa","cmc":"130 Pa"},{"name":"Gaz; Nadciśnienie","range":"od -1 kPa do 1 kPa","cmc":"3,2 Pa"},{"name":"Gaz; Nadciśnienie","range":"od 1 kPa do 35 kPa","cmc":"18 Pa"},{"name":"Gaz; Nadciśnienie","range":"od 35 kPa do 7 MPa","cmc":"0,05 %"},{"name":"Ciecz; Ciśnienie bezwzględne","range":"od 0 kPa do 7 MPa","cmc":"0,05 % + 100 Pa"},{"name":"Ciecz; Ciśnienie bezwzględne","range":"od 7 MPa do 70 MPa","cmc":"0,05 %"},{"name":"Ciecz; Ciśnienie bezwzględne","range":"od 70 MPa do 140 MPa","cmc":"0,2 %"},{"name":"Ciecz; Nadciśnienie","range":"od 0 MPa do 1,4 MPa","cmc":"1,4 kPa"},{"name":"Ciecz; Nadciśnienie","range":"od 1,4 MPa do 70 MPa","cmc":"0,05 %"},{"name":"Ciecz; Nadciśnienie","range":"od 70 MPa do 140 MPa","cmc":"0,2 %"}],"parameters_en":[{"name":"Gas; Absolute pressure","range":"0 kPa to 7 MPa","cmc":"0,05 % + 100 Pa"},{"name":"Gas; Overpressure","range":"-100 kPa to -1 kPa","cmc":"130 Pa"},{"name":"Gas; Overpressure","range":"-1 kPa to 1 kPa","cmc":"3,2 Pa"},{"name":"Gas; Overpressure","range":"1 kPa to 35 kPa","cmc":"18 Pa"},{"name":"Gas; Overpressure","range":"35 kPa to 7 MPa","cmc":"0,05 %"},{"name":"Liquids; Absolute pressure","range":"0 kPa to 7 MPa","cmc":"0,05 % + 100 Pa"},{"name":"Liquids; Absolute pressure","range":"7 MPa to 70 MPa","cmc":"0,05 %"},{"name":"Liquids; Absolute pressure","range":"70 MPa to 140 MPa","cmc":"0,2 %"},{"name":"Liquids; Overpressure","range":"0 MPa to 1,4 MPa","cmc":"1,4 kPa"},{"name":"Liquids; Overpressure","range":"1,4 MPa to 70 MPa","cmc":"0,05 %"},{"name":"Liquids; Overpressure","range":"70 MPa to 140 MPa","cmc":"0,2 %"}],"parameters_zh":[{"name":"气体；绝对压力","range":"0 kPa 至 7 MPa","cmc":"0,05 % + 100 Pa"},{"name":"气体；表压","range":"-100 kPa 至 -1 kPa","cmc":"130 Pa"},{"name":"气体；表压","range":"-1 kPa 至 1 kPa","cmc":"3,2 Pa"},{"name":"气体；表压","range":"1 kPa 至 35 kPa","cmc":"18 Pa"},{"name":"气体；表压","range":"35 kPa 至 7 MPa","cmc":"0,05 %"},{"name":"液体；绝对压力","range":"0 kPa 至 7 MPa","cmc":"0,05 % + 100 Pa"},{"name":"液体；绝对压力","range":"7 MPa 至 70 MPa","cmc":"0,05 %"},{"name":"液体；绝对压力","range":"70 MPa 至 140 MPa","cmc":"0,2 %"},{"name":"液体；表压","range":"0 MPa 至 1,4 MPa","cmc":"1,4 kPa"},{"name":"液体；表压","range":"1,4 MPa 至 70 MPa","cmc":"0,05 %"},{"name":"液体；表压","range":"70 MPa 至 140 MPa","cmc":"0,2 %"}],"parameters_cs":[{"name":"Plyn; Absolutní tlak","range":"0 kPa až 7 MPa","cmc":"0,05 % + 100 Pa"},{"name":"Plyn; Přetlak","range":"-100 kPa až -1 kPa","cmc":"130 Pa"},{"name":"Plyn; Přetlak","range":"-1 kPa až 1 kPa","cmc":"3,2 Pa"},{"name":"Plyn; Přetlak","range":"1 kPa až 35 kPa","cmc":"18 Pa"},{"name":"Plyn; Přetlak","range":"35 kPa až 7 MPa","cmc":"0,05 %"},{"name":"Kapalina; Absolutní tlak","range":"0 kPa až 7 MPa","cmc":"0,05 % + 100 Pa"},{"name":"Kapalina; Absolutní tlak","range":"7 MPa až 70 MPa","cmc":"0,05 %"},{"name":"Kapalina; Absolutní tlak","range":"70 MPa až 140 MPa","cmc":"0,2 %"},{"name":"Kapalina; Přetlak","range":"0 MPa až 1,4 MPa","cmc":"1,4 kPa"},{"name":"Kapalina; Přetlak","range":"1,4 MPa až 70 MPa","cmc":"0,05 %"},{"name":"Kapalina; Přetlak","range":"70 MPa až 140 MPa","cmc":"0,2 %"}],"technique":"Pomiar porównawczy z wzorcowym manometrem cyfrowym","technique_en":"Comparative measurement by a reference digital pressure gauge","technique_zh":"与标准数字压力表比较测量","technique_cs":"Porovnávací měření s etalonovým digitálním manometrem","techniques":["Pomiar porównawczy z wzorcowym manometrem cyfrowym"],"techniques_en":["Comparative measurement by a reference digital pressure gauge"],"techniques_zh":["与标准数字压力表比较测量"],"techniques_cs":["Porovnávací měření s etalonovým digitálním manometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nGaz; Ciśnienie bezwzględne od 0 kPa do 7 MPa CMC 0,05 % + 100 Pa\nGaz; Nadciśnienie od -100 kPa do -1 kPa CMC 130 Pa\nGaz; Nadciśnienie od -1 kPa do 1 kPa CMC 3,2 Pa\nGaz; Nadciśnienie od 1 kPa do 35 kPa CMC 18 Pa\nGaz; Nadciśnienie od 35 kPa do 7 MPa CMC 0,05 %\nCiecz; Ciśnienie bezwzględne od 0 kPa do 7 MPa CMC 0,05 % + 100 Pa\nCiecz; Ciśnienie bezwzględne od 7 MPa do 70 MPa CMC 0,05 %\nCiecz; Ciśnienie bezwzględne od 70 MPa do 140 MPa CMC 0,2 %\nCiecz; Nadciśnienie od 0 MPa do 1,4 MPa CMC 1,4 kPa\nCiecz; Nadciśnienie od 1,4 MPa do 70 MPa CMC 0,05 %\nCiecz; Nadciśnienie od 70 MPa do 140 MPa CMC 0,2 %\nPomiar porównawczy z wzorcowym manometrem cyfrowym","reference":"KP T1, KP T2","norm_bases":["KP T1","KP T2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste, ciśnieniomierze do opon, ciśnieniomierze elektromechaniczne (ciśnieniomierze cyfrowe, przetworniki ciśnienia z wyjściem cyfrowym) Wzorcowanie – ciśnienie Pomiar porównawczy z wzorcowym manometrem cyfrowym Gaz; Ciśnienie bezwzględne od 0 kPa do 7 MPa CMC 0,05 % + 100 Pa Gaz; Nadciśnienie od -100 kPa do -1 kPa CMC 130 Pa Gaz; Nadciśnienie od -1 kPa do 1 kPa CMC 3,2 Pa Gaz; Nadciśnienie od 1 kPa do 35 kPa CMC 18 Pa Gaz; Nadciśnienie od 35 kPa do 7 MPa CMC 0,05 % Ciecz; Ciśnienie bezwzględne od 0 kPa do 7 MPa CMC 0,05 % + 100 Pa Ciecz; Ciśnienie bezwzględne od 7 MPa do 70 MPa CMC 0,05 % Ciecz; Ciśnienie bezwzględne od 70 MPa do 140 MPa CMC 0,2 % Ciecz; Nadciśnienie od 0 MPa do 1,4 MPa CMC 1,4 kPa Ciecz; Nadciśnienie od 1,4 MPa do 70 MPa CMC 0,05 % Ciecz; Nadciśnienie od 70 MPa do 140 MPa CMC 0,2 % Deformační tlakoměry, měřidla tlaku v pneumatikách, elektromechanické tlakoměry (číslicové tlakoměry, převodníky tlaku s digitálním výstupem měřené veličiny) Kalibrace – tlak Porovnávací měření s etalonovým digitálním manometrem Plyn; Absolutní tlak 0 kPa až 7 MPa CMC 0,05 % + 100 Pa Plyn; Přetlak -100 kPa až -1 kPa CMC 130 Pa Plyn; Přetlak -1 kPa až 1 kPa CMC 3,2 Pa Plyn; Přetlak 1 kPa až 35 kPa CMC 18 Pa Plyn; Přetlak 35 kPa až 7 MPa CMC 0,05 % Kapalina; Absolutní tlak 0 kPa až 7 MPa CMC 0,05 % + 100 Pa Kapalina; Absolutní tlak 7 MPa až 70 MPa CMC 0,05 % Kapalina; Absolutní tlak 70 MPa až 140 MPa CMC 0,2 % Kapalina; Přetlak 0 MPa až 1,4 MPa CMC 1,4 kPa Kapalina; Přetlak 1,4 MPa až 70 MPa CMC 0,05 % Kapalina; Přetlak 70 MPa až 140 MPa CMC 0,2 % KP T1, KP T2 Cisnieniomierze sprezyste, cisnieniomierze do opon, cisnieniomierze elektromechaniczne (cisnieniomierze cyfrowe, przetworniki cisnienia z wyjsciem cyfrowym) Wzorcowanie – cisnienie Pomiar porownawczy z wzorcowym manometrem cyfrowym Gaz; Cisnienie bezwzgledne od 0 kPa do 7 MPa CMC 0,05 % + 100 Pa Gaz; Nadcisnienie od -100 kPa do -1 kPa CMC 130 Pa Gaz; Nadcisnienie od -1 kPa do 1 kPa CMC 3,2 Pa Gaz; Nadcisnienie od 1 kPa do 35 kPa CMC 18 Pa Gaz; Nadcisnienie od 35 kPa do 7 MPa CMC 0,05 % Ciecz; Cisnienie bezwzgledne od 0 kPa do 7 MPa CMC 0,05 % + 100 Pa Ciecz; Cisnienie bezwzgledne od 7 MPa do 70 MPa CMC 0,05 % Ciecz; Cisnienie bezwzgledne od 70 MPa do 140 MPa CMC 0,2 % Ciecz; Nadcisnienie od 0 MPa do 1,4 MPa CMC 1,4 kPa Ciecz; Nadcisnienie od 1,4 MPa do 70 MPa CMC 0,05 % Ciecz; Nadcisnienie od 70 MPa do 140 MPa CMC 0,2 % Deformacni tlakomery, meridla tlaku v pneumatikach, elektromechanicke tlakomery (cislicove tlakomery, prevodniky tlaku s digitalnim vystupem merene veliciny) Kalibrace – tlak Porovnavaci mereni s etalonovym digitalnim manometrem Plyn; Absolutni tlak 0 kPa az 7 MPa CMC 0,05 % + 100 Pa Plyn; Pretlak -100 kPa az -1 kPa CMC 130 Pa Plyn; Pretlak -1 kPa az 1 kPa CMC 3,2 Pa Plyn; Pretlak 1 kPa az 35 kPa CMC 18 Pa Plyn; Pretlak 35 kPa az 7 MPa CMC 0,05 % Kapalina; Absolutni tlak 0 kPa az 7 MPa CMC 0,05 % + 100 Pa Kapalina; Absolutni tlak 7 MPa az 70 MPa CMC 0,05 % Kapalina; Absolutni tlak 70 MPa az 140 MPa CMC 0,2 % Kapalina; Pretlak 0 MPa az 1,4 MPa CMC 1,4 kPa Kapalina; Pretlak 1,4 MPa az 70 MPa CMC 0,05 % Kapalina; Pretlak 70 MPa az 140 MPa CMC 0,2 % KP T1, KP T2","search_en":"Deformation manometers, tyre pressure gauges, electromechanical pressure gauges (digital pressure gauges, pressure transducers with digital output of the measured quantity) Calibration – pressure Comparative measurement by a reference digital pressure gauge Gas; Absolute pressure 0 kPa to 7 MPa CMC 0,05 % + 100 Pa Gas; Overpressure -100 kPa to -1 kPa CMC 130 Pa Gas; Overpressure -1 kPa to 1 kPa CMC 3,2 Pa Gas; Overpressure 1 kPa to 35 kPa CMC 18 Pa Gas; Overpressure 35 kPa to 7 MPa CMC 0,05 % Liquids; Absolute pressure 0 kPa to 7 MPa CMC 0,05 % + 100 Pa Liquids; Absolute pressure 7 MPa to 70 MPa CMC 0,05 % Liquids; Absolute pressure 70 MPa to 140 MPa CMC 0,2 % Liquids; Overpressure 0 MPa to 1,4 MPa CMC 1,4 kPa Liquids; Overpressure 1,4 MPa to 70 MPa CMC 0,05 % Liquids; Overpressure 70 MPa to 140 MPa CMC 0,2 % KP T1, KP T2","search_zh":"弹性压力表、轮胎压力表、机电式压力表（数字压力表、带数字输出的压力变送器） 校准 – 压力 与标准数字压力表比较测量 气体；绝对压力 0 kPa 至 7 MPa CMC 0,05 % + 100 Pa 气体；表压 -100 kPa 至 -1 kPa CMC 130 Pa 气体；表压 -1 kPa 至 1 kPa CMC 3,2 Pa 气体；表压 1 kPa 至 35 kPa CMC 18 Pa 气体；表压 35 kPa 至 7 MPa CMC 0,05 % 液体；绝对压力 0 kPa 至 7 MPa CMC 0,05 % + 100 Pa 液体；绝对压力 7 MPa 至 70 MPa CMC 0,05 % 液体；绝对压力 70 MPa 至 140 MPa CMC 0,2 % 液体；表压 0 MPa 至 1,4 MPa CMC 1,4 kPa 液体；表压 1,4 MPa 至 70 MPa CMC 0,05 % 液体；表压 70 MPa 至 140 MPa CMC 0,2 % KP T1, KP T2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3189e5a40887f2ab12f36420","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -50 °C do 0 °C","cmc":"0,14 °C"},{"name":"","range":"od 100 °C do 200 °C","cmc":"0,22 °C"},{"name":"","range":"od 200 °C do 300 °C","cmc":"0,32 °C"},{"name":"","range":"od 300 °C do 400 °C","cmc":"0,42 °C"},{"name":"","range":"od 400 °C do 500 °C","cmc":"0,52 °C"},{"name":"","range":"od 500 °C do 650 °C","cmc":"0,67 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 0 °C","cmc":"0,14 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,22 °C"},{"name":"","range":"200 °C to 300 °C","cmc":"0,32 °C"},{"name":"","range":"300 °C to 400 °C","cmc":"0,42 °C"},{"name":"","range":"400 °C to 500 °C","cmc":"0,52 °C"},{"name":"","range":"500 °C to 650 °C","cmc":"0,67 °C"}],"parameters_zh":[{"name":"","range":"-50 °C 至 0 °C","cmc":"0,14 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,22 °C"},{"name":"","range":"200 °C 至 300 °C","cmc":"0,32 °C"},{"name":"","range":"300 °C 至 400 °C","cmc":"0,42 °C"},{"name":"","range":"400 °C 至 500 °C","cmc":"0,52 °C"},{"name":"","range":"500 °C 至 650 °C","cmc":"0,67 °C"}],"parameters_cs":[{"name":"","range":"-50 °C až 0 °C","cmc":"0,14 °C"},{"name":"","range":"100 °C až 200 °C","cmc":"0,22 °C"},{"name":"","range":"200 °C až 300 °C","cmc":"0,32 °C"},{"name":"","range":"300 °C až 400 °C","cmc":"0,42 °C"},{"name":"","range":"400 °C až 500 °C","cmc":"0,52 °C"},{"name":"","range":"500 °C až 650 °C","cmc":"0,67 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w piecu blokowym","technique_en":"Comparison with a reference digital thermometer in a dry block calibrator","technique_zh":"在干体炉中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v blokové pícce","techniques":["Porównanie z wzorcowym termometrem cyfrowym w piecu blokowym"],"techniques_en":["Comparison with a reference digital thermometer in a dry block calibrator"],"techniques_zh":["在干体炉中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v blokové pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -50 °C do 0 °C CMC 0,14 °C\nod 100 °C do 200 °C CMC 0,22 °C\nod 200 °C do 300 °C CMC 0,32 °C\nod 300 °C do 400 °C CMC 0,42 °C\nod 400 °C do 500 °C CMC 0,52 °C\nod 500 °C do 650 °C CMC 0,67 °C\nPorównanie z wzorcowym termometrem cyfrowym w piecu blokowym","reference":"KP TE1","norm_bases":["KP TE1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w piecu blokowym od -50 °C do 0 °C CMC 0,14 °C od 100 °C do 200 °C CMC 0,22 °C od 200 °C do 300 °C CMC 0,32 °C od 300 °C do 400 °C CMC 0,42 °C od 400 °C do 500 °C CMC 0,52 °C od 500 °C do 650 °C CMC 0,67 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v blokové pícce -50 °C až 0 °C CMC 0,14 °C 100 °C až 200 °C CMC 0,22 °C 200 °C až 300 °C CMC 0,32 °C 300 °C až 400 °C CMC 0,42 °C 400 °C až 500 °C CMC 0,52 °C 500 °C až 650 °C CMC 0,67 °C KP TE1 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w piecu blokowym od -50 °C do 0 °C CMC 0,14 °C od 100 °C do 200 °C CMC 0,22 °C od 200 °C do 300 °C CMC 0,32 °C od 300 °C do 400 °C CMC 0,42 °C od 400 °C do 500 °C CMC 0,52 °C od 500 °C do 650 °C CMC 0,67 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v blokove picce -50 °C az 0 °C CMC 0,14 °C 100 °C az 200 °C CMC 0,22 °C 200 °C az 300 °C CMC 0,32 °C 300 °C az 400 °C CMC 0,42 °C 400 °C az 500 °C CMC 0,52 °C 500 °C az 650 °C CMC 0,67 °C KP TE1","search_en":"Direct-indicating thermometers Calibration – temperature Comparison with a reference digital thermometer in a dry block calibrator -50 °C to 0 °C CMC 0,14 °C 100 °C to 200 °C CMC 0,22 °C 200 °C to 300 °C CMC 0,32 °C 300 °C to 400 °C CMC 0,42 °C 400 °C to 500 °C CMC 0,52 °C 500 °C to 650 °C CMC 0,67 °C KP TE1","search_zh":"直读式温度计 校准 – 温度 在干体炉中与标准数字温度计比较 -50 °C 至 0 °C CMC 0,14 °C 100 °C 至 200 °C CMC 0,22 °C 200 °C 至 300 °C CMC 0,32 °C 300 °C 至 400 °C CMC 0,42 °C 400 °C 至 500 °C CMC 0,52 °C 500 °C 至 650 °C CMC 0,67 °C KP TE1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dfd2347b58577848351fd28c","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 100 °C","cmc":"0,08 °C"}],"parameters_en":[{"name":"","range":"0 °C to 100 °C","cmc":"0,08 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 100 °C","cmc":"0,08 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 100 °C","cmc":"0,08 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","technique_en":"Comparison with a reference digital thermometer in a liquid bath","technique_zh":"在液体槽中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej"],"techniques_en":["Comparison with a reference digital thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 0 °C do 100 °C CMC 0,08 °C\nPorównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","reference":"KP TE1","norm_bases":["KP TE1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej od 0 °C do 100 °C CMC 0,08 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v kapalinové lázni 0 °C až 100 °C CMC 0,08 °C KP TE1 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w lazni cieczowej od 0 °C do 100 °C CMC 0,08 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v kapalinove lazni 0 °C az 100 °C CMC 0,08 °C KP TE1","search_en":"Direct-indicating thermometers Calibration – temperature Comparison with a reference digital thermometer in a liquid bath 0 °C to 100 °C CMC 0,08 °C KP TE1","search_zh":"直读式温度计 校准 – 温度 在液体槽中与标准数字温度计比较 0 °C 至 100 °C CMC 0,08 °C KP TE1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"41dc960e935c6b68bb67c64e","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 650 °C do 1100 °C","cmc":"1,5 °C"}],"parameters_en":[{"name":"","range":"650 °C to 1100 °C","cmc":"1,5 °C"}],"parameters_zh":[{"name":"","range":"650 °C 至 1100 °C","cmc":"1,5 °C"}],"parameters_cs":[{"name":"","range":"650 °C až 1100 °C","cmc":"1,5 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w piecu powietrznym","technique_en":"Comparison with a reference digital thermometer in an air oven","technique_zh":"在空气炉中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem ve vzduchové pícce","techniques":["Porównanie z wzorcowym termometrem cyfrowym w piecu powietrznym"],"techniques_en":["Comparison with a reference digital thermometer in an air oven"],"techniques_zh":["在空气炉中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem ve vzduchové pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 650 °C do 1100 °C CMC 1,5 °C\nPorównanie z wzorcowym termometrem cyfrowym w piecu powietrznym","reference":"KP TE1","norm_bases":["KP TE1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w piecu powietrznym od 650 °C do 1100 °C CMC 1,5 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem ve vzduchové pícce 650 °C až 1100 °C CMC 1,5 °C KP TE1 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w piecu powietrznym od 650 °C do 1100 °C CMC 1,5 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem ve vzduchove picce 650 °C az 1100 °C CMC 1,5 °C KP TE1","search_en":"Direct-indicating thermometers Calibration – temperature Comparison with a reference digital thermometer in an air oven 650 °C to 1100 °C CMC 1,5 °C KP TE1","search_zh":"直读式温度计 校准 – 温度 在空气炉中与标准数字温度计比较 650 °C 至 1100 °C CMC 1,5 °C KP TE1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bc3405f5182cf664356a0341","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezdotykowe","test_object_en":"Contactless thermometers","test_object_zh":"非接触式温度计","test_object_cs":"Teploměry bezdotykové","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -10 °C do 200 °C","cmc":"3,0 °C"},{"name":"","range":"od 200 °C do 500 °C","cmc":"6,0 °C"},{"name":"","range":"od 500 °C do 800 °C","cmc":"10,0 °C"}],"parameters_en":[{"name":"","range":"-10 °C to 200 °C","cmc":"3,0 °C"},{"name":"","range":"200 °C to 500 °C","cmc":"6,0 °C"},{"name":"","range":"500 °C to 800 °C","cmc":"10,0 °C"}],"parameters_zh":[{"name":"","range":"-10 °C 至 200 °C","cmc":"3,0 °C"},{"name":"","range":"200 °C 至 500 °C","cmc":"6,0 °C"},{"name":"","range":"500 °C 至 800 °C","cmc":"10,0 °C"}],"parameters_cs":[{"name":"","range":"-10 °C až 200 °C","cmc":"3,0 °C"},{"name":"","range":"200 °C až 500 °C","cmc":"6,0 °C"},{"name":"","range":"500 °C až 800 °C","cmc":"10,0 °C"}],"technique":"Porównanie z pirometrem wzorcowym na tarczowym lub wnękowym ciele czarnym","technique_en":"Comparison with a reference pyrometer on target-type or cavity-type black body","technique_zh":"在面源或空腔黑体上与标准高温计比较","technique_cs":"Porovnání s etalonovým pyrometrem na terčovém nebo dutinovém černém tělese","techniques":["Porównanie z pirometrem wzorcowym na tarczowym lub wnękowym ciele czarnym"],"techniques_en":["Comparison with a reference pyrometer on target-type or cavity-type black body"],"techniques_zh":["在面源或空腔黑体上与标准高温计比较"],"techniques_cs":["Porovnání s etalonovým pyrometrem na terčovém nebo dutinovém černém tělese"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -10 °C do 200 °C CMC 3,0 °C\nod 200 °C do 500 °C CMC 6,0 °C\nod 500 °C do 800 °C CMC 10,0 °C\nPorównanie z pirometrem wzorcowym na tarczowym lub wnękowym ciele czarnym","reference":"KP TE4","norm_bases":["KP TE4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezdotykowe Wzorcowanie – temperatura Porównanie z pirometrem wzorcowym na tarczowym lub wnękowym ciele czarnym od -10 °C do 200 °C CMC 3,0 °C od 200 °C do 500 °C CMC 6,0 °C od 500 °C do 800 °C CMC 10,0 °C Teploměry bezdotykové Kalibrace – teplota Porovnání s etalonovým pyrometrem na terčovém nebo dutinovém černém tělese -10 °C až 200 °C CMC 3,0 °C 200 °C až 500 °C CMC 6,0 °C 500 °C až 800 °C CMC 10,0 °C KP TE4 Termometry bezdotykowe Wzorcowanie – temperatura Porownanie z pirometrem wzorcowym na tarczowym lub wnekowym ciele czarnym od -10 °C do 200 °C CMC 3,0 °C od 200 °C do 500 °C CMC 6,0 °C od 500 °C do 800 °C CMC 10,0 °C Teplomery bezdotykove Kalibrace – teplota Porovnani s etalonovym pyrometrem na tercovem nebo dutinovem cernem telese -10 °C az 200 °C CMC 3,0 °C 200 °C az 500 °C CMC 6,0 °C 500 °C az 800 °C CMC 10,0 °C KP TE4","search_en":"Contactless thermometers Calibration – temperature Comparison with a reference pyrometer on target-type or cavity-type black body -10 °C to 200 °C CMC 3,0 °C 200 °C to 500 °C CMC 6,0 °C 500 °C to 800 °C CMC 10,0 °C KP TE4","search_zh":"非接触式温度计 校准 – 温度 在面源或空腔黑体上与标准高温计比较 -10 °C 至 200 °C CMC 3,0 °C 200 °C 至 500 °C CMC 6,0 °C 500 °C 至 800 °C CMC 10,0 °C KP TE4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1c3552364176ba1851b16d0e","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermoelectric temperature sensors","test_object_zh":"热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -50 °C do 0 °C","cmc":"0,7 °C"},{"name":"","range":"od 100 °C do 550 °C","cmc":"0,9 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 0 °C","cmc":"0,7 °C"},{"name":"","range":"100 °C to 550 °C","cmc":"0,9 °C"}],"parameters_zh":[{"name":"","range":"-50 °C 至 0 °C","cmc":"0,7 °C"},{"name":"","range":"100 °C 至 550 °C","cmc":"0,9 °C"}],"parameters_cs":[{"name":"","range":"-50 °C až 0 °C","cmc":"0,7 °C"},{"name":"","range":"100 °C až 550 °C","cmc":"0,9 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w piecu blokowym","technique_en":"Comparison with a reference digital thermometer in a dry block calibrator","technique_zh":"在干体炉中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v blokové pícce","techniques":["Porównanie z wzorcowym termometrem cyfrowym w piecu blokowym"],"techniques_en":["Comparison with a reference digital thermometer in a dry block calibrator"],"techniques_zh":["在干体炉中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v blokové pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -50 °C do 0 °C CMC 0,7 °C\nod 100 °C do 550 °C CMC 0,9 °C\nPorównanie z wzorcowym termometrem cyfrowym w piecu blokowym","reference":"KP TE2","norm_bases":["KP TE2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w piecu blokowym od -50 °C do 0 °C CMC 0,7 °C od 100 °C do 550 °C CMC 0,9 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v blokové pícce -50 °C až 0 °C CMC 0,7 °C 100 °C až 550 °C CMC 0,9 °C KP TE2 Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w piecu blokowym od -50 °C do 0 °C CMC 0,7 °C od 100 °C do 550 °C CMC 0,9 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v blokove picce -50 °C az 0 °C CMC 0,7 °C 100 °C az 550 °C CMC 0,9 °C KP TE2","search_en":"Thermoelectric temperature sensors Calibration – temperature Comparison with a reference digital thermometer in a dry block calibrator -50 °C to 0 °C CMC 0,7 °C 100 °C to 550 °C CMC 0,9 °C KP TE2","search_zh":"热电式温度传感器 校准 – 温度 在干体炉中与标准数字温度计比较 -50 °C 至 0 °C CMC 0,7 °C 100 °C 至 550 °C CMC 0,9 °C KP TE2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"da1b45c1576c1bd94e7d8304","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermoelectric temperature sensors","test_object_zh":"热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 100 °C","cmc":"0,7 °C"}],"parameters_en":[{"name":"","range":"0 °C to 100 °C","cmc":"0,7 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 100 °C","cmc":"0,7 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 100 °C","cmc":"0,7 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","technique_en":"Comparison with a reference digital thermometer in a liquid bath","technique_zh":"在液体槽中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej"],"techniques_en":["Comparison with a reference digital thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 0 °C do 100 °C CMC 0,7 °C\nPorównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","reference":"KP TE2","norm_bases":["KP TE2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej od 0 °C do 100 °C CMC 0,7 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v kapalinové lázni 0 °C až 100 °C CMC 0,7 °C KP TE2 Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w lazni cieczowej od 0 °C do 100 °C CMC 0,7 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v kapalinove lazni 0 °C az 100 °C CMC 0,7 °C KP TE2","search_en":"Thermoelectric temperature sensors Calibration – temperature Comparison with a reference digital thermometer in a liquid bath 0 °C to 100 °C CMC 0,7 °C KP TE2","search_zh":"热电式温度传感器 校准 – 温度 在液体槽中与标准数字温度计比较 0 °C 至 100 °C CMC 0,7 °C KP TE2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"268e46397fac524a7588f5c3","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermoelectric temperature sensors","test_object_zh":"热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 550 °C do 800 °C","cmc":"2,3 °C"}],"parameters_en":[{"name":"","range":"550 °C to 800 °C","cmc":"2,3 °C"}],"parameters_zh":[{"name":"","range":"550 °C 至 800 °C","cmc":"2,3 °C"}],"parameters_cs":[{"name":"","range":"550 °C až 800 °C","cmc":"2,3 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w piecu powietrznym","technique_en":"Comparison with a reference digital thermometer in an air oven","technique_zh":"在空气炉中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem ve vzduchové pícce","techniques":["Porównanie z wzorcowym termometrem cyfrowym w piecu powietrznym"],"techniques_en":["Comparison with a reference digital thermometer in an air oven"],"techniques_zh":["在空气炉中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem ve vzduchové pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 550 °C do 800 °C CMC 2,3 °C\nPorównanie z wzorcowym termometrem cyfrowym w piecu powietrznym","reference":"KP TE2","norm_bases":["KP TE2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w piecu powietrznym od 550 °C do 800 °C CMC 2,3 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem ve vzduchové pícce 550 °C až 800 °C CMC 2,3 °C KP TE2 Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w piecu powietrznym od 550 °C do 800 °C CMC 2,3 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem ve vzduchove picce 550 °C az 800 °C CMC 2,3 °C KP TE2","search_en":"Thermoelectric temperature sensors Calibration – temperature Comparison with a reference digital thermometer in an air oven 550 °C to 800 °C CMC 2,3 °C KP TE2","search_zh":"热电式温度传感器 校准 – 温度 在空气炉中与标准数字温度计比较 550 °C 至 800 °C CMC 2,3 °C KP TE2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d6e1b031fca7f8152bef68a1","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"3","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻式温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -50 °C do 0 °C","cmc":"0,15 °C"},{"name":"","range":"od 100 °C do 400 °C","cmc":"0,45 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 0 °C","cmc":"0,15 °C"},{"name":"","range":"100 °C to 400 °C","cmc":"0,45 °C"}],"parameters_zh":[{"name":"","range":"-50 °C 至 0 °C","cmc":"0,15 °C"},{"name":"","range":"100 °C 至 400 °C","cmc":"0,45 °C"}],"parameters_cs":[{"name":"","range":"-50 °C až 0 °C","cmc":"0,15 °C"},{"name":"","range":"100 °C až 400 °C","cmc":"0,45 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w piecu blokowym","technique_en":"Comparison with a reference digital thermometer in a dry block calibrator","technique_zh":"在干体炉中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v blokové pícce","techniques":["Porównanie z wzorcowym termometrem cyfrowym w piecu blokowym"],"techniques_en":["Comparison with a reference digital thermometer in a dry block calibrator"],"techniques_zh":["在干体炉中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v blokové pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -50 °C do 0 °C CMC 0,15 °C\nod 100 °C do 400 °C CMC 0,45 °C\nPorównanie z wzorcowym termometrem cyfrowym w piecu blokowym","reference":"KP TE3","norm_bases":["KP TE3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w piecu blokowym od -50 °C do 0 °C CMC 0,15 °C od 100 °C do 400 °C CMC 0,45 °C Odporové snímače teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v blokové pícce -50 °C až 0 °C CMC 0,15 °C 100 °C až 400 °C CMC 0,45 °C KP TE3 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w piecu blokowym od -50 °C do 0 °C CMC 0,15 °C od 100 °C do 400 °C CMC 0,45 °C Odporove snimace teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v blokove picce -50 °C az 0 °C CMC 0,15 °C 100 °C az 400 °C CMC 0,45 °C KP TE3","search_en":"Resistance temperature sensors Calibration – temperature Comparison with a reference digital thermometer in a dry block calibrator -50 °C to 0 °C CMC 0,15 °C 100 °C to 400 °C CMC 0,45 °C KP TE3","search_zh":"电阻式温度传感器 校准 – 温度 在干体炉中与标准数字温度计比较 -50 °C 至 0 °C CMC 0,15 °C 100 °C 至 400 °C CMC 0,45 °C KP TE3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"185bcb3d518faf754fa66c2c","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"3","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻式温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 100 °C","cmc":"0,13 °C"}],"parameters_en":[{"name":"","range":"0 °C to 100 °C","cmc":"0,13 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 100 °C","cmc":"0,13 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 100 °C","cmc":"0,13 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","technique_en":"Comparison with a reference digital thermometer in a liquid bath","technique_zh":"在液体槽中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej"],"techniques_en":["Comparison with a reference digital thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 0 °C do 100 °C CMC 0,13 °C\nPorównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","reference":"KP TE3","norm_bases":["KP TE3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej od 0 °C do 100 °C CMC 0,13 °C Odporové snímače teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v kapalinové lázni 0 °C až 100 °C CMC 0,13 °C KP TE3 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w lazni cieczowej od 0 °C do 100 °C CMC 0,13 °C Odporove snimace teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v kapalinove lazni 0 °C az 100 °C CMC 0,13 °C KP TE3","search_en":"Resistance temperature sensors Calibration – temperature Comparison with a reference digital thermometer in a liquid bath 0 °C to 100 °C CMC 0,13 °C KP TE3","search_zh":"电阻式温度传感器 校准 – 温度 在液体槽中与标准数字温度计比较 0 °C 至 100 °C CMC 0,13 °C KP TE3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e16729a1f69c773bccf0a1ee","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / źródła napięcia stałego","test_object_en":"DC voltage / DC voltage sources","test_object_zh":"直流电压 / 直流电压源","test_object_cs":"Stejnosměrné napětí / Zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,0062 % + 6,1 µV"},{"name":"","range":"od 0,1 V do 1 V","cmc":"0,0047 % + 16 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,0047 % + 0,14 mV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,0079 % + 2,0 mV"},{"name":"","range":"od 100 V do 1000 V","cmc":"0,0079 % + 20 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,0062 % + 6,1 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"0,0047 % + 16 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0047 % + 0,14 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,0079 % + 2,0 mV"},{"name":"","range":"100 V to 1000 V","cmc":"0,0079 % + 20 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,0062 % + 6,1 µV"},{"name":"","range":"0,1 V 至 1 V","cmc":"0,0047 % + 16 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,0047 % + 0,14 mV"},{"name":"","range":"10 V 至 100 V","cmc":"0,0079 % + 2,0 mV"},{"name":"","range":"100 V 至 1000 V","cmc":"0,0079 % + 20 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,0062 % + 6,1 µV"},{"name":"","range":"0,1 V až 1 V","cmc":"0,0047 % + 16 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,0047 % + 0,14 mV"},{"name":"","range":"10 V až 100 V","cmc":"0,0079 % + 2,0 mV"},{"name":"","range":"100 V až 1000 V","cmc":"0,0079 % + 20 mV"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,0062 % + 6,1 µV\nod 0,1 V do 1 V CMC 0,0047 % + 16 µV\nod 1 V do 10 V CMC 0,0047 % + 0,14 mV\nod 10 V do 100 V CMC 0,0079 % + 2,0 mV\nod 100 V do 1000 V CMC 0,0079 % + 20 mV\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP EL2","norm_bases":["KP EL2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / źródła napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0062 % + 6,1 µV od 0,1 V do 1 V CMC 0,0047 % + 16 µV od 1 V do 10 V CMC 0,0047 % + 0,14 mV od 10 V do 100 V CMC 0,0079 % + 2,0 mV od 100 V do 1000 V CMC 0,0079 % + 20 mV Stejnosměrné napětí / Zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 mV až 100 mV CMC 0,0062 % + 6,1 µV 0,1 V až 1 V CMC 0,0047 % + 16 µV 1 V až 10 V CMC 0,0047 % + 0,14 mV 10 V až 100 V CMC 0,0079 % + 2,0 mV 100 V až 1000 V CMC 0,0079 % + 20 mV KP EL2 Napiecie stale / zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0062 % + 6,1 µV od 0,1 V do 1 V CMC 0,0047 % + 16 µV od 1 V do 10 V CMC 0,0047 % + 0,14 mV od 10 V do 100 V CMC 0,0079 % + 2,0 mV od 100 V do 1000 V CMC 0,0079 % + 20 mV Stejnosmerne napeti / Zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 mV az 100 mV CMC 0,0062 % + 6,1 µV 0,1 V az 1 V CMC 0,0047 % + 16 µV 1 V az 10 V CMC 0,0047 % + 0,14 mV 10 V az 100 V CMC 0,0079 % + 2,0 mV 100 V az 1000 V CMC 0,0079 % + 20 mV KP EL2","search_en":"DC voltage / DC voltage sources Calibration – electrical quantities Direct measurement by a standard multimeter 0 mV to 100 mV CMC 0,0062 % + 6,1 µV 0,1 V to 1 V CMC 0,0047 % + 16 µV 1 V to 10 V CMC 0,0047 % + 0,14 mV 10 V to 100 V CMC 0,0079 % + 2,0 mV 100 V to 1000 V CMC 0,0079 % + 20 mV KP EL2","search_zh":"直流电压 / 直流电压源 校准 – 电学量 用标准万用表直接测量 0 mV 至 100 mV CMC 0,0062 % + 6,1 µV 0,1 V 至 1 V CMC 0,0047 % + 16 µV 1 V 至 10 V CMC 0,0047 % + 0,14 mV 10 V 至 100 V CMC 0,0079 % + 2,0 mV 100 V 至 1000 V CMC 0,0079 % + 20 mV KP EL2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3f5a9127fa933310a358f60f","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Napięcie stałe / mierniki napięcia stałego","test_object_en":"DC voltage / DC voltage meters","test_object_zh":"直流电压 / 直流电压测量仪器","test_object_cs":"Stejnosměrné napětí / Měřidla stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 200 mV","cmc":"0,0053 % + 7,7 µV"},{"name":"","range":"od 0,2 V do 2 V","cmc":"0,0028 % + 15 µV"},{"name":"","range":"od 2 V do 20 V","cmc":"0,0028 % + 0,15 mV"},{"name":"","range":"od 20 V do 200 V","cmc":"0,0028 % + 1,5 mV"},{"name":"","range":"od 200 V do 1000 V","cmc":"0,0035 % + 17 mV"}],"parameters_en":[{"name":"","range":"0 mV to 200 mV","cmc":"0,0053 % + 7,7 µV"},{"name":"","range":"0,2 V to 2 V","cmc":"0,0028 % + 15 µV"},{"name":"","range":"2 V to 20 V","cmc":"0,0028 % + 0,15 mV"},{"name":"","range":"20 V to 200 V","cmc":"0,0028 % + 1,5 mV"},{"name":"","range":"200 V to 1000 V","cmc":"0,0035 % + 17 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 200 mV","cmc":"0,0053 % + 7,7 µV"},{"name":"","range":"0,2 V 至 2 V","cmc":"0,0028 % + 15 µV"},{"name":"","range":"2 V 至 20 V","cmc":"0,0028 % + 0,15 mV"},{"name":"","range":"20 V 至 200 V","cmc":"0,0028 % + 1,5 mV"},{"name":"","range":"200 V 至 1000 V","cmc":"0,0035 % + 17 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 200 mV","cmc":"0,0053 % + 7,7 µV"},{"name":"","range":"0,2 V až 2 V","cmc":"0,0028 % + 15 µV"},{"name":"","range":"2 V až 20 V","cmc":"0,0028 % + 0,15 mV"},{"name":"","range":"20 V až 200 V","cmc":"0,0028 % + 1,5 mV"},{"name":"","range":"200 V až 1000 V","cmc":"0,0035 % + 17 mV"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a standard calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a standard calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 200 mV CMC 0,0053 % + 7,7 µV\nod 0,2 V do 2 V CMC 0,0028 % + 15 µV\nod 2 V do 20 V CMC 0,0028 % + 0,15 mV\nod 20 V do 200 V CMC 0,0028 % + 1,5 mV\nod 200 V do 1000 V CMC 0,0035 % + 17 mV\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"KP EL1","norm_bases":["KP EL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / mierniki napięcia stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym od 0 mV do 200 mV CMC 0,0053 % + 7,7 µV od 0,2 V do 2 V CMC 0,0028 % + 15 µV od 2 V do 20 V CMC 0,0028 % + 0,15 mV od 20 V do 200 V CMC 0,0028 % + 1,5 mV od 200 V do 1000 V CMC 0,0035 % + 17 mV Stejnosměrné napětí / Měřidla stejnosměrného napětí Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 0 mV až 200 mV CMC 0,0053 % + 7,7 µV 0,2 V až 2 V CMC 0,0028 % + 15 µV 2 V až 20 V CMC 0,0028 % + 0,15 mV 20 V až 200 V CMC 0,0028 % + 1,5 mV 200 V až 1000 V CMC 0,0035 % + 17 mV KP EL1 Napiecie stale / mierniki napiecia stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym od 0 mV do 200 mV CMC 0,0053 % + 7,7 µV od 0,2 V do 2 V CMC 0,0028 % + 15 µV od 2 V do 20 V CMC 0,0028 % + 0,15 mV od 20 V do 200 V CMC 0,0028 % + 1,5 mV od 200 V do 1000 V CMC 0,0035 % + 17 mV Stejnosmerne napeti / Meridla stejnosmerneho napeti Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 0 mV az 200 mV CMC 0,0053 % + 7,7 µV 0,2 V az 2 V CMC 0,0028 % + 15 µV 2 V az 20 V CMC 0,0028 % + 0,15 mV 20 V az 200 V CMC 0,0028 % + 1,5 mV 200 V az 1000 V CMC 0,0035 % + 17 mV KP EL1","search_en":"DC voltage / DC voltage meters Calibration – electrical quantities Direct generation with a standard calibrator 0 mV to 200 mV CMC 0,0053 % + 7,7 µV 0,2 V to 2 V CMC 0,0028 % + 15 µV 2 V to 20 V CMC 0,0028 % + 0,15 mV 20 V to 200 V CMC 0,0028 % + 1,5 mV 200 V to 1000 V CMC 0,0035 % + 17 mV KP EL1","search_zh":"直流电压 / 直流电压测量仪器 校准 – 电学量 用标准校准器直接产生 0 mV 至 200 mV CMC 0,0053 % + 7,7 µV 0,2 V 至 2 V CMC 0,0028 % + 15 µV 2 V 至 20 V CMC 0,0028 % + 0,15 mV 20 V 至 200 V CMC 0,0028 % + 1,5 mV 200 V 至 1000 V CMC 0,0035 % + 17 mV KP EL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"accf14abdb0cfe0fb20944eb","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła prądu stałego","test_object_en":"Direct current / Direct current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / Zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 10 µA","cmc":"0,050 % + 6,1 nA"},{"name":"","range":"od 10 µA do 100 µA","cmc":"0,074 % + 17 nA"},{"name":"","range":"od 0,1 mA do 1 mA","cmc":"0,075 % + 0,16 µA"},{"name":"","range":"od 1 mA do 10 mA","cmc":"0,034 % + 1,2 µA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,034 % + 12 µA"},{"name":"","range":"od 100 mA do 1 A","cmc":"0,068 % + 0,15 mA"},{"name":"","range":"od 1 A do 3 A","cmc":"0,061 % + 1,1 mA"}],"parameters_en":[{"name":"","range":"0 µA to 10 µA","cmc":"0,050 % + 6,1 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"0,074 % + 17 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"0,075 % + 0,16 µA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,034 % + 1,2 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,034 % + 12 µA"},{"name":"","range":"100 mA to 1 A","cmc":"0,068 % + 0,15 mA"},{"name":"","range":"1 A to 3 A","cmc":"0,061 % + 1,1 mA"}],"parameters_zh":[{"name":"","range":"0 µA 至 10 µA","cmc":"0,050 % + 6,1 nA"},{"name":"","range":"10 µA 至 100 µA","cmc":"0,074 % + 17 nA"},{"name":"","range":"0,1 mA 至 1 mA","cmc":"0,075 % + 0,16 µA"},{"name":"","range":"1 mA 至 10 mA","cmc":"0,034 % + 1,2 µA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,034 % + 12 µA"},{"name":"","range":"100 mA 至 1 A","cmc":"0,068 % + 0,15 mA"},{"name":"","range":"1 A 至 3 A","cmc":"0,061 % + 1,1 mA"}],"parameters_cs":[{"name":"","range":"0 µA až 10 µA","cmc":"0,050 % + 6,1 nA"},{"name":"","range":"10 µA až 100 µA","cmc":"0,074 % + 17 nA"},{"name":"","range":"0,1 mA až 1 mA","cmc":"0,075 % + 0,16 µA"},{"name":"","range":"1 mA až 10 mA","cmc":"0,034 % + 1,2 µA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,034 % + 12 µA"},{"name":"","range":"100 mA až 1 A","cmc":"0,068 % + 0,15 mA"},{"name":"","range":"1 A až 3 A","cmc":"0,061 % + 1,1 mA"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 10 µA CMC 0,050 % + 6,1 nA\nod 10 µA do 100 µA CMC 0,074 % + 17 nA\nod 0,1 mA do 1 mA CMC 0,075 % + 0,16 µA\nod 1 mA do 10 mA CMC 0,034 % + 1,2 µA\nod 10 mA do 100 mA CMC 0,034 % + 12 µA\nod 100 mA do 1 A CMC 0,068 % + 0,15 mA\nod 1 A do 3 A CMC 0,061 % + 1,1 mA\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP EL2","norm_bases":["KP EL2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 µA do 10 µA CMC 0,050 % + 6,1 nA od 10 µA do 100 µA CMC 0,074 % + 17 nA od 0,1 mA do 1 mA CMC 0,075 % + 0,16 µA od 1 mA do 10 mA CMC 0,034 % + 1,2 µA od 10 mA do 100 mA CMC 0,034 % + 12 µA od 100 mA do 1 A CMC 0,068 % + 0,15 mA od 1 A do 3 A CMC 0,061 % + 1,1 mA Stejnosměrný proud / Zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 µA až 10 µA CMC 0,050 % + 6,1 nA 10 µA až 100 µA CMC 0,074 % + 17 nA 0,1 mA až 1 mA CMC 0,075 % + 0,16 µA 1 mA až 10 mA CMC 0,034 % + 1,2 µA 10 mA až 100 mA CMC 0,034 % + 12 µA 100 mA až 1 A CMC 0,068 % + 0,15 mA 1 A až 3 A CMC 0,061 % + 1,1 mA KP EL2 Prad staly / zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 µA do 10 µA CMC 0,050 % + 6,1 nA od 10 µA do 100 µA CMC 0,074 % + 17 nA od 0,1 mA do 1 mA CMC 0,075 % + 0,16 µA od 1 mA do 10 mA CMC 0,034 % + 1,2 µA od 10 mA do 100 mA CMC 0,034 % + 12 µA od 100 mA do 1 A CMC 0,068 % + 0,15 mA od 1 A do 3 A CMC 0,061 % + 1,1 mA Stejnosmerny proud / Zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 µA az 10 µA CMC 0,050 % + 6,1 nA 10 µA az 100 µA CMC 0,074 % + 17 nA 0,1 mA az 1 mA CMC 0,075 % + 0,16 µA 1 mA az 10 mA CMC 0,034 % + 1,2 µA 10 mA az 100 mA CMC 0,034 % + 12 µA 100 mA az 1 A CMC 0,068 % + 0,15 mA 1 A az 3 A CMC 0,061 % + 1,1 mA KP EL2","search_en":"Direct current / Direct current sources Calibration – electrical quantities Direct measurement by a standard multimeter 0 µA to 10 µA CMC 0,050 % + 6,1 nA 10 µA to 100 µA CMC 0,074 % + 17 nA 0,1 mA to 1 mA CMC 0,075 % + 0,16 µA 1 mA to 10 mA CMC 0,034 % + 1,2 µA 10 mA to 100 mA CMC 0,034 % + 12 µA 100 mA to 1 A CMC 0,068 % + 0,15 mA 1 A to 3 A CMC 0,061 % + 1,1 mA KP EL2","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用标准万用表直接测量 0 µA 至 10 µA CMC 0,050 % + 6,1 nA 10 µA 至 100 µA CMC 0,074 % + 17 nA 0,1 mA 至 1 mA CMC 0,075 % + 0,16 µA 1 mA 至 10 mA CMC 0,034 % + 1,2 µA 10 mA 至 100 mA CMC 0,034 % + 12 µA 100 mA 至 1 A CMC 0,068 % + 0,15 mA 1 A 至 3 A CMC 0,061 % + 1,1 mA KP EL2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aba09c0c7e75621b42f78ff5","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"4","test_object":"Prąd stały / mierniki prądu stałego","test_object_en":"Direct current / Direct current meters","test_object_zh":"直流电流 / 直流电流测量仪器","test_object_cs":"Stejnosměrný proud / Měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 200 µA","cmc":"0,020 % + 73 nA"},{"name":"","range":"od 0,2 mA do 2 mA","cmc":"0,016 % + 0,13 µA"},{"name":"","range":"od 2 mA do 20 mA","cmc":"0,009 % + 0,94 µA"},{"name":"","range":"od 20 mA do 200 mA","cmc":"0,012 % + 9,7 µA"},{"name":"","range":"od 0,2 A do 2 A","cmc":"0,018 % + 0,13 mA"},{"name":"","range":"od 2 A do 30 A","cmc":"0,069 % + 2,5 mA"}],"parameters_en":[{"name":"","range":"0 µA to 200 µA","cmc":"0,020 % + 73 nA"},{"name":"","range":"0,2 mA to 2 mA","cmc":"0,016 % + 0,13 µA"},{"name":"","range":"2 mA to 20 mA","cmc":"0,009 % + 0,94 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"0,012 % + 9,7 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"0,018 % + 0,13 mA"},{"name":"","range":"2 A to 30 A","cmc":"0,069 % + 2,5 mA"}],"parameters_zh":[{"name":"","range":"0 µA 至 200 µA","cmc":"0,020 % + 73 nA"},{"name":"","range":"0,2 mA 至 2 mA","cmc":"0,016 % + 0,13 µA"},{"name":"","range":"2 mA 至 20 mA","cmc":"0,009 % + 0,94 µA"},{"name":"","range":"20 mA 至 200 mA","cmc":"0,012 % + 9,7 µA"},{"name":"","range":"0,2 A 至 2 A","cmc":"0,018 % + 0,13 mA"},{"name":"","range":"2 A 至 30 A","cmc":"0,069 % + 2,5 mA"}],"parameters_cs":[{"name":"","range":"0 µA až 200 µA","cmc":"0,020 % + 73 nA"},{"name":"","range":"0,2 mA až 2 mA","cmc":"0,016 % + 0,13 µA"},{"name":"","range":"2 mA až 20 mA","cmc":"0,009 % + 0,94 µA"},{"name":"","range":"20 mA až 200 mA","cmc":"0,012 % + 9,7 µA"},{"name":"","range":"0,2 A až 2 A","cmc":"0,018 % + 0,13 mA"},{"name":"","range":"2 A až 30 A","cmc":"0,069 % + 2,5 mA"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a standard calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a standard calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 200 µA CMC 0,020 % + 73 nA\nod 0,2 mA do 2 mA CMC 0,016 % + 0,13 µA\nod 2 mA do 20 mA CMC 0,009 % + 0,94 µA\nod 20 mA do 200 mA CMC 0,012 % + 9,7 µA\nod 0,2 A do 2 A CMC 0,018 % + 0,13 mA\nod 2 A do 30 A CMC 0,069 % + 2,5 mA\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"KP EL1","norm_bases":["KP EL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki prądu stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym od 0 µA do 200 µA CMC 0,020 % + 73 nA od 0,2 mA do 2 mA CMC 0,016 % + 0,13 µA od 2 mA do 20 mA CMC 0,009 % + 0,94 µA od 20 mA do 200 mA CMC 0,012 % + 9,7 µA od 0,2 A do 2 A CMC 0,018 % + 0,13 mA od 2 A do 30 A CMC 0,069 % + 2,5 mA Stejnosměrný proud / Měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 0 µA až 200 µA CMC 0,020 % + 73 nA 0,2 mA až 2 mA CMC 0,016 % + 0,13 µA 2 mA až 20 mA CMC 0,009 % + 0,94 µA 20 mA až 200 mA CMC 0,012 % + 9,7 µA 0,2 A až 2 A CMC 0,018 % + 0,13 mA 2 A až 30 A CMC 0,069 % + 2,5 mA KP EL1 Prad staly / mierniki pradu stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym od 0 µA do 200 µA CMC 0,020 % + 73 nA od 0,2 mA do 2 mA CMC 0,016 % + 0,13 µA od 2 mA do 20 mA CMC 0,009 % + 0,94 µA od 20 mA do 200 mA CMC 0,012 % + 9,7 µA od 0,2 A do 2 A CMC 0,018 % + 0,13 mA od 2 A do 30 A CMC 0,069 % + 2,5 mA Stejnosmerny proud / Meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 0 µA az 200 µA CMC 0,020 % + 73 nA 0,2 mA az 2 mA CMC 0,016 % + 0,13 µA 2 mA az 20 mA CMC 0,009 % + 0,94 µA 20 mA az 200 mA CMC 0,012 % + 9,7 µA 0,2 A az 2 A CMC 0,018 % + 0,13 mA 2 A az 30 A CMC 0,069 % + 2,5 mA KP EL1","search_en":"Direct current / Direct current meters Calibration – electrical quantities Direct generation with a standard calibrator 0 µA to 200 µA CMC 0,020 % + 73 nA 0,2 mA to 2 mA CMC 0,016 % + 0,13 µA 2 mA to 20 mA CMC 0,009 % + 0,94 µA 20 mA to 200 mA CMC 0,012 % + 9,7 µA 0,2 A to 2 A CMC 0,018 % + 0,13 mA 2 A to 30 A CMC 0,069 % + 2,5 mA KP EL1","search_zh":"直流电流 / 直流电流测量仪器 校准 – 电学量 用标准校准器直接产生 0 µA 至 200 µA CMC 0,020 % + 73 nA 0,2 mA 至 2 mA CMC 0,016 % + 0,13 µA 2 mA 至 20 mA CMC 0,009 % + 0,94 µA 20 mA 至 200 mA CMC 0,012 % + 9,7 µA 0,2 A 至 2 A CMC 0,018 % + 0,13 mA 2 A 至 30 A CMC 0,069 % + 2,5 mA KP EL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ba1824b6e9a1038636983f27","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"4","test_object":"Prąd stały / mierniki prądu stałego","test_object_en":"Direct current / Direct current meters","test_object_zh":"直流电流 / 直流电流测量仪器","test_object_cs":"Stejnosměrný proud / Měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 30 A do 1500 A","cmc":"0,42 % + 0,13 A"}],"parameters_en":[{"name":"","range":"30 A to 1500 A","cmc":"0,42 % + 0,13 A"}],"parameters_zh":[{"name":"","range":"30 A 至 1500 A","cmc":"0,42 % + 0,13 A"}],"parameters_cs":[{"name":"","range":"30 A až 1500 A","cmc":"0,42 % + 0,13 A"}],"technique":"Symulacja za pomocą cewki prądowej","technique_en":"Simulation using current coil","technique_zh":"用电流线圈模拟","technique_cs":"Simulace pomocí proudové cívky","techniques":["Symulacja za pomocą cewki prądowej"],"techniques_en":["Simulation using current coil"],"techniques_zh":["用电流线圈模拟"],"techniques_cs":["Simulace pomocí proudové cívky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 30 A do 1500 A CMC 0,42 % + 0,13 A\nSymulacja za pomocą cewki prądowej","reference":"KP EL1","norm_bases":["KP EL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki prądu stałego Wzorcowanie – wielkości elektryczne Symulacja za pomocą cewki prądowej od 30 A do 1500 A CMC 0,42 % + 0,13 A Stejnosměrný proud / Měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Simulace pomocí proudové cívky 30 A až 1500 A CMC 0,42 % + 0,13 A KP EL1 Prad staly / mierniki pradu stalego Wzorcowanie – wielkosci elektryczne Symulacja za pomoca cewki pradowej od 30 A do 1500 A CMC 0,42 % + 0,13 A Stejnosmerny proud / Meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Simulace pomoci proudove civky 30 A az 1500 A CMC 0,42 % + 0,13 A KP EL1","search_en":"Direct current / Direct current meters Calibration – electrical quantities Simulation using current coil 30 A to 1500 A CMC 0,42 % + 0,13 A KP EL1","search_zh":"直流电流 / 直流电流测量仪器 校准 – 电学量 用电流线圈模拟 30 A 至 1500 A CMC 0,42 % + 0,13 A KP EL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"573498112761fe49d74fda40","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"5","test_object":"Napięcie przemienne / źródła napięcia przemiennego","test_object_en":"AC voltage / AC voltage sources","test_object_zh":"交流电压 / 交流电压源","test_object_cs":"Střídavé napětí / Zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 20 kHz","range":"od 0,1 mV do 100 mV","cmc":"0,086 % + 36 µV"},{"name":"20 kHz do 50 kHz","range":"od 0,1 mV do 100 mV","cmc":"0,16 % + 59 µV"},{"name":"50 kHz do 100 kHz","range":"od 0,1 mV do 100 mV","cmc":"0,69 % + 93 µV"},{"name":"10 Hz do 20 kHz","range":"od 0,1 V do 1 V","cmc":"0,076 % + 0,43 mV"},{"name":"20 kHz do 50 kHz","range":"od 0,1 V do 1 V","cmc":"0,14 % + 0,73 mV"},{"name":"50 kHz do 100 kHz","range":"od 0,1 V do 1 V","cmc":"0,71 % + 0,81 mV"},{"name":"10 Hz do 20 kHz","range":"od 1 V do 10 V","cmc":"0,076 % + 4,4 mV"},{"name":"20 kHz do 50 kHz","range":"od 1 V do 10 V","cmc":"0,14 % + 7,3 mV"},{"name":"50 kHz do 100 kHz","range":"od 1 V do 10 V","cmc":"0,71 % + 17 mV"},{"name":"10 Hz do 20 kHz","range":"od 10 V do 100 V","cmc":"0,076 % + 44 mV"},{"name":"20 kHz do 50 kHz","range":"od 10 V do 100 V","cmc":"0,14 % + 73 mV"},{"name":"50 kHz do 100 kHz","range":"od 10 V do 100 V","cmc":"0,71 % + 81 mV"},{"name":"10 Hz do 20 kHz","range":"od 100 V do 750 V","cmc":"0,07 % + 0,35 V"},{"name":"20 kHz do 50 kHz","range":"od 100 V do 750 V","cmc":"0,14 % + 0,59 V"},{"name":"50 kHz do 100 kHz","range":"od 100 V do 750 V","cmc":"0,61 % + 1,5 V"}],"parameters_en":[{"name":"10 Hz to 20 kHz","range":"0,1 mV to 100 mV","cmc":"0,086 % + 36 µV"},{"name":"20 kHz to 50 kHz","range":"0,1 mV to 100 mV","cmc":"0,16 % + 59 µV"},{"name":"50 kHz to 100 kHz","range":"0,1 mV to 100 mV","cmc":"0,69 % + 93 µV"},{"name":"10 Hz to 20 kHz","range":"0,1 V to 1 V","cmc":"0,076 % + 0,43 mV"},{"name":"20 kHz to 50 kHz","range":"0,1 V to 1 V","cmc":"0,14 % + 0,73 mV"},{"name":"50 kHz to 100 kHz","range":"0,1 V to 1 V","cmc":"0,71 % + 0,81 mV"},{"name":"10 Hz to 20 kHz","range":"1 V to 10 V","cmc":"0,076 % + 4,4 mV"},{"name":"20 kHz to 50 kHz","range":"1 V to 10 V","cmc":"0,14 % + 7,3 mV"},{"name":"50 kHz to 100 kHz","range":"1 V to 10 V","cmc":"0,71 % + 17 mV"},{"name":"10 Hz to 20 kHz","range":"10 V to 100 V","cmc":"0,076 % + 44 mV"},{"name":"20 kHz to 50 kHz","range":"10 V to 100 V","cmc":"0,14 % + 73 mV"},{"name":"50 kHz to 100 kHz","range":"10 V to 100 V","cmc":"0,71 % + 81 mV"},{"name":"10 Hz to 20 kHz","range":"100 V to 750 V","cmc":"0,07 % + 0,35 V"},{"name":"20 kHz to 50 kHz","range":"100 V to 750 V","cmc":"0,14 % + 0,59 V"},{"name":"50 kHz to 100 kHz","range":"100 V to 750 V","cmc":"0,61 % + 1,5 V"}],"parameters_zh":[{"name":"10 Hz 至 20 kHz","range":"0,1 mV 至 100 mV","cmc":"0,086 % + 36 µV"},{"name":"20 kHz 至 50 kHz","range":"0,1 mV 至 100 mV","cmc":"0,16 % + 59 µV"},{"name":"50 kHz 至 100 kHz","range":"0,1 mV 至 100 mV","cmc":"0,69 % + 93 µV"},{"name":"10 Hz 至 20 kHz","range":"0,1 V 至 1 V","cmc":"0,076 % + 0,43 mV"},{"name":"20 kHz 至 50 kHz","range":"0,1 V 至 1 V","cmc":"0,14 % + 0,73 mV"},{"name":"50 kHz 至 100 kHz","range":"0,1 V 至 1 V","cmc":"0,71 % + 0,81 mV"},{"name":"10 Hz 至 20 kHz","range":"1 V 至 10 V","cmc":"0,076 % + 4,4 mV"},{"name":"20 kHz 至 50 kHz","range":"1 V 至 10 V","cmc":"0,14 % + 7,3 mV"},{"name":"50 kHz 至 100 kHz","range":"1 V 至 10 V","cmc":"0,71 % + 17 mV"},{"name":"10 Hz 至 20 kHz","range":"10 V 至 100 V","cmc":"0,076 % + 44 mV"},{"name":"20 kHz 至 50 kHz","range":"10 V 至 100 V","cmc":"0,14 % + 73 mV"},{"name":"50 kHz 至 100 kHz","range":"10 V 至 100 V","cmc":"0,71 % + 81 mV"},{"name":"10 Hz 至 20 kHz","range":"100 V 至 750 V","cmc":"0,07 % + 0,35 V"},{"name":"20 kHz 至 50 kHz","range":"100 V 至 750 V","cmc":"0,14 % + 0,59 V"},{"name":"50 kHz 至 100 kHz","range":"100 V 至 750 V","cmc":"0,61 % + 1,5 V"}],"parameters_cs":[{"name":"10 Hz až 20 kHz","range":"0,1 mV až 100 mV","cmc":"0,086 % + 36 µV"},{"name":"20 kHz až 50 kHz","range":"0,1 mV až 100 mV","cmc":"0,16 % + 59 µV"},{"name":"50 kHz až 100 kHz","range":"0,1 mV až 100 mV","cmc":"0,69 % + 93 µV"},{"name":"10 Hz až 20 kHz","range":"0,1 V až 1 V","cmc":"0,076 % + 0,43 mV"},{"name":"20 kHz až 50 kHz","range":"0,1 V až 1 V","cmc":"0,14 % + 0,73 mV"},{"name":"50 kHz až 100 kHz","range":"0,1 V až 1 V","cmc":"0,71 % + 0,81 mV"},{"name":"10 Hz až 20 kHz","range":"1 V až 10 V","cmc":"0,076 % + 4,4 mV"},{"name":"20 kHz až 50 kHz","range":"1 V až 10 V","cmc":"0,14 % + 7,3 mV"},{"name":"50 kHz až 100 kHz","range":"1 V až 10 V","cmc":"0,71 % + 17 mV"},{"name":"10 Hz až 20 kHz","range":"10 V až 100 V","cmc":"0,076 % + 44 mV"},{"name":"20 kHz až 50 kHz","range":"10 V až 100 V","cmc":"0,14 % + 73 mV"},{"name":"50 kHz až 100 kHz","range":"10 V až 100 V","cmc":"0,71 % + 81 mV"},{"name":"10 Hz až 20 kHz","range":"100 V až 750 V","cmc":"0,07 % + 0,35 V"},{"name":"20 kHz až 50 kHz","range":"100 V až 750 V","cmc":"0,14 % + 0,59 V"},{"name":"50 kHz až 100 kHz","range":"100 V až 750 V","cmc":"0,61 % + 1,5 V"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 20 kHz od 0,1 mV do 100 mV CMC 0,086 % + 36 µV\n20 kHz do 50 kHz od 0,1 mV do 100 mV CMC 0,16 % + 59 µV\n50 kHz do 100 kHz od 0,1 mV do 100 mV CMC 0,69 % + 93 µV\n10 Hz do 20 kHz od 0,1 V do 1 V CMC 0,076 % + 0,43 mV\n20 kHz do 50 kHz od 0,1 V do 1 V CMC 0,14 % + 0,73 mV\n50 kHz do 100 kHz od 0,1 V do 1 V CMC 0,71 % + 0,81 mV\n10 Hz do 20 kHz od 1 V do 10 V CMC 0,076 % + 4,4 mV\n20 kHz do 50 kHz od 1 V do 10 V CMC 0,14 % + 7,3 mV\n50 kHz do 100 kHz od 1 V do 10 V CMC 0,71 % + 17 mV\n10 Hz do 20 kHz od 10 V do 100 V CMC 0,076 % + 44 mV\n20 kHz do 50 kHz od 10 V do 100 V CMC 0,14 % + 73 mV\n50 kHz do 100 kHz od 10 V do 100 V CMC 0,71 % + 81 mV\n10 Hz do 20 kHz od 100 V do 750 V CMC 0,07 % + 0,35 V\n20 kHz do 50 kHz od 100 V do 750 V CMC 0,14 % + 0,59 V\n50 kHz do 100 kHz od 100 V do 750 V CMC 0,61 % + 1,5 V\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP EL2","norm_bases":["KP EL2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 10 Hz do 20 kHz od 0,1 mV do 100 mV CMC 0,086 % + 36 µV 20 kHz do 50 kHz od 0,1 mV do 100 mV CMC 0,16 % + 59 µV 50 kHz do 100 kHz od 0,1 mV do 100 mV CMC 0,69 % + 93 µV 10 Hz do 20 kHz od 0,1 V do 1 V CMC 0,076 % + 0,43 mV 20 kHz do 50 kHz od 0,1 V do 1 V CMC 0,14 % + 0,73 mV 50 kHz do 100 kHz od 0,1 V do 1 V CMC 0,71 % + 0,81 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,076 % + 4,4 mV 20 kHz do 50 kHz od 1 V do 10 V CMC 0,14 % + 7,3 mV 50 kHz do 100 kHz od 1 V do 10 V CMC 0,71 % + 17 mV 10 Hz do 20 kHz od 10 V do 100 V CMC 0,076 % + 44 mV 20 kHz do 50 kHz od 10 V do 100 V CMC 0,14 % + 73 mV 50 kHz do 100 kHz od 10 V do 100 V CMC 0,71 % + 81 mV 10 Hz do 20 kHz od 100 V do 750 V CMC 0,07 % + 0,35 V 20 kHz do 50 kHz od 100 V do 750 V CMC 0,14 % + 0,59 V 50 kHz do 100 kHz od 100 V do 750 V CMC 0,61 % + 1,5 V Střídavé napětí / Zdroje střídavého napětí Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 10 Hz až 20 kHz 0,1 mV až 100 mV CMC 0,086 % + 36 µV 20 kHz až 50 kHz 0,1 mV až 100 mV CMC 0,16 % + 59 µV 50 kHz až 100 kHz 0,1 mV až 100 mV CMC 0,69 % + 93 µV 10 Hz až 20 kHz 0,1 V až 1 V CMC 0,076 % + 0,43 mV 20 kHz až 50 kHz 0,1 V až 1 V CMC 0,14 % + 0,73 mV 50 kHz až 100 kHz 0,1 V až 1 V CMC 0,71 % + 0,81 mV 10 Hz až 20 kHz 1 V až 10 V CMC 0,076 % + 4,4 mV 20 kHz až 50 kHz 1 V až 10 V CMC 0,14 % + 7,3 mV 50 kHz až 100 kHz 1 V až 10 V CMC 0,71 % + 17 mV 10 Hz až 20 kHz 10 V až 100 V CMC 0,076 % + 44 mV 20 kHz až 50 kHz 10 V až 100 V CMC 0,14 % + 73 mV 50 kHz až 100 kHz 10 V až 100 V CMC 0,71 % + 81 mV 10 Hz až 20 kHz 100 V až 750 V CMC 0,07 % + 0,35 V 20 kHz až 50 kHz 100 V až 750 V CMC 0,14 % + 0,59 V 50 kHz až 100 kHz 100 V až 750 V CMC 0,61 % + 1,5 V KP EL2 Napiecie przemienne / zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 10 Hz do 20 kHz od 0,1 mV do 100 mV CMC 0,086 % + 36 µV 20 kHz do 50 kHz od 0,1 mV do 100 mV CMC 0,16 % + 59 µV 50 kHz do 100 kHz od 0,1 mV do 100 mV CMC 0,69 % + 93 µV 10 Hz do 20 kHz od 0,1 V do 1 V CMC 0,076 % + 0,43 mV 20 kHz do 50 kHz od 0,1 V do 1 V CMC 0,14 % + 0,73 mV 50 kHz do 100 kHz od 0,1 V do 1 V CMC 0,71 % + 0,81 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,076 % + 4,4 mV 20 kHz do 50 kHz od 1 V do 10 V CMC 0,14 % + 7,3 mV 50 kHz do 100 kHz od 1 V do 10 V CMC 0,71 % + 17 mV 10 Hz do 20 kHz od 10 V do 100 V CMC 0,076 % + 44 mV 20 kHz do 50 kHz od 10 V do 100 V CMC 0,14 % + 73 mV 50 kHz do 100 kHz od 10 V do 100 V CMC 0,71 % + 81 mV 10 Hz do 20 kHz od 100 V do 750 V CMC 0,07 % + 0,35 V 20 kHz do 50 kHz od 100 V do 750 V CMC 0,14 % + 0,59 V 50 kHz do 100 kHz od 100 V do 750 V CMC 0,61 % + 1,5 V Stridave napeti / Zdroje stridaveho napeti Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 10 Hz az 20 kHz 0,1 mV az 100 mV CMC 0,086 % + 36 µV 20 kHz az 50 kHz 0,1 mV az 100 mV CMC 0,16 % + 59 µV 50 kHz az 100 kHz 0,1 mV az 100 mV CMC 0,69 % + 93 µV 10 Hz az 20 kHz 0,1 V az 1 V CMC 0,076 % + 0,43 mV 20 kHz az 50 kHz 0,1 V az 1 V CMC 0,14 % + 0,73 mV 50 kHz az 100 kHz 0,1 V az 1 V CMC 0,71 % + 0,81 mV 10 Hz az 20 kHz 1 V az 10 V CMC 0,076 % + 4,4 mV 20 kHz az 50 kHz 1 V az 10 V CMC 0,14 % + 7,3 mV 50 kHz az 100 kHz 1 V az 10 V CMC 0,71 % + 17 mV 10 Hz az 20 kHz 10 V az 100 V CMC 0,076 % + 44 mV 20 kHz az 50 kHz 10 V az 100 V CMC 0,14 % + 73 mV 50 kHz az 100 kHz 10 V az 100 V CMC 0,71 % + 81 mV 10 Hz az 20 kHz 100 V az 750 V CMC 0,07 % + 0,35 V 20 kHz az 50 kHz 100 V az 750 V CMC 0,14 % + 0,59 V 50 kHz az 100 kHz 100 V az 750 V CMC 0,61 % + 1,5 V KP EL2","search_en":"AC voltage / AC voltage sources Calibration – electrical quantities Direct measurement by a standard multimeter 10 Hz to 20 kHz 0,1 mV to 100 mV CMC 0,086 % + 36 µV 20 kHz to 50 kHz 0,1 mV to 100 mV CMC 0,16 % + 59 µV 50 kHz to 100 kHz 0,1 mV to 100 mV CMC 0,69 % + 93 µV 10 Hz to 20 kHz 0,1 V to 1 V CMC 0,076 % + 0,43 mV 20 kHz to 50 kHz 0,1 V to 1 V CMC 0,14 % + 0,73 mV 50 kHz to 100 kHz 0,1 V to 1 V CMC 0,71 % + 0,81 mV 10 Hz to 20 kHz 1 V to 10 V CMC 0,076 % + 4,4 mV 20 kHz to 50 kHz 1 V to 10 V CMC 0,14 % + 7,3 mV 50 kHz to 100 kHz 1 V to 10 V CMC 0,71 % + 17 mV 10 Hz to 20 kHz 10 V to 100 V CMC 0,076 % + 44 mV 20 kHz to 50 kHz 10 V to 100 V CMC 0,14 % + 73 mV 50 kHz to 100 kHz 10 V to 100 V CMC 0,71 % + 81 mV 10 Hz to 20 kHz 100 V to 750 V CMC 0,07 % + 0,35 V 20 kHz to 50 kHz 100 V to 750 V CMC 0,14 % + 0,59 V 50 kHz to 100 kHz 100 V to 750 V CMC 0,61 % + 1,5 V KP EL2","search_zh":"交流电压 / 交流电压源 校准 – 电学量 用标准万用表直接测量 10 Hz 至 20 kHz 0,1 mV 至 100 mV CMC 0,086 % + 36 µV 20 kHz 至 50 kHz 0,1 mV 至 100 mV CMC 0,16 % + 59 µV 50 kHz 至 100 kHz 0,1 mV 至 100 mV CMC 0,69 % + 93 µV 10 Hz 至 20 kHz 0,1 V 至 1 V CMC 0,076 % + 0,43 mV 20 kHz 至 50 kHz 0,1 V 至 1 V CMC 0,14 % + 0,73 mV 50 kHz 至 100 kHz 0,1 V 至 1 V CMC 0,71 % + 0,81 mV 10 Hz 至 20 kHz 1 V 至 10 V CMC 0,076 % + 4,4 mV 20 kHz 至 50 kHz 1 V 至 10 V CMC 0,14 % + 7,3 mV 50 kHz 至 100 kHz 1 V 至 10 V CMC 0,71 % + 17 mV 10 Hz 至 20 kHz 10 V 至 100 V CMC 0,076 % + 44 mV 20 kHz 至 50 kHz 10 V 至 100 V CMC 0,14 % + 73 mV 50 kHz 至 100 kHz 10 V 至 100 V CMC 0,71 % + 81 mV 10 Hz 至 20 kHz 100 V 至 750 V CMC 0,07 % + 0,35 V 20 kHz 至 50 kHz 100 V 至 750 V CMC 0,14 % + 0,59 V 50 kHz 至 100 kHz 100 V 至 750 V CMC 0,61 % + 1,5 V KP EL2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e1483bf17a60216bd09b4254","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"6","test_object":"Napięcie przemienne / mierniki napięcia przemiennego","test_object_en":"AC voltage / AC voltage meters","test_object_zh":"交流电压 / 交流电压测量仪器","test_object_cs":"Střídavé napětí / Měřidla střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 45 Hz","range":"od 0,1 mV do 200 mV","cmc":"0,16 % + 64 µV"},{"name":"45 Hz do 10 kHz","range":"od 0,1 mV do 200 mV","cmc":"0,049 % + 69 µV"},{"name":"10 kHz do 20 kHz","range":"od 0,1 mV do 200 mV","cmc":"0,12 % + 86 µV"},{"name":"20 kHz do 50 kHz","range":"od 0,1 mV do 200 mV","cmc":"0,20 % + 98 µV"},{"name":"10 Hz do 45 Hz","range":"od 0,2 V do 2 V","cmc":"0,082 % + 0,38 mV"},{"name":"45 Hz do 10 kHz","range":"od 0,2 V do 2 V","cmc":"0,042 % + 0,29 mV"},{"name":"10 kHz do 20 kHz","range":"od 0,2 V do 2 V","cmc":"0,12 % + 0,46 mV"},{"name":"20 kHz do 50 kHz","range":"od 0,2 V do 2 V","cmc":"0,17 % + 0,73 mV"},{"name":"10 Hz do 45 Hz","range":"od 2 V do 20 V","cmc":"0,084 % + 3,8 mV"},{"name":"45 Hz do 10 kHz","range":"od 2 V do 20 V","cmc":"0,042 % + 2,7 mV"},{"name":"10 kHz do 20 kHz","range":"od 2 V do 20 V","cmc":"0,12 % + 4,7 mV"},{"name":"20 kHz do 50 kHz","range":"od 2 V do 20 V","cmc":"0,17 % + 5,6 mV"},{"name":"30 Hz do 45 Hz","range":"od 20 V do 200 V","cmc":"0,082 % + 31 mV"},{"name":"45 Hz do 10 kHz","range":"od 20 V do 200 V","cmc":"0,10 % + 43 mV"},{"name":"10 kHz do 20 kHz","range":"od 20 V do 200 V","cmc":"0,14 % + 56 mV"},{"name":"20 kHz do 40 kHz","range":"od 20 V do 200 V","cmc":"0,17 % + 61 mV"},{"name":"30 Hz do 45 Hz","range":"od 200 V do 1000 V","cmc":"0,082 % + 0,45 V"},{"name":"45 Hz do 1 kHz","range":"od 200 V do 1000 V","cmc":"0,09 % + 0,28 V"},{"name":"1 kHz do 5 kHz","range":"od 200 V do 1000 V","cmc":"0,14 % + 0,38 V"},{"name":"5 kHz do 10 kHz","range":"od 200 V do 1000 V","cmc":"0,16 % + 0,49 V"}],"parameters_en":[{"name":"10 Hz to 45 Hz","range":"0,1 mV to 200 mV","cmc":"0,16 % + 64 µV"},{"name":"45 Hz to 10 kHz","range":"0,1 mV to 200 mV","cmc":"0,049 % + 69 µV"},{"name":"10 kHz to 20 kHz","range":"0,1 mV to 200 mV","cmc":"0,12 % + 86 µV"},{"name":"20 kHz to 50 kHz","range":"0,1 mV to 200 mV","cmc":"0,20 % + 98 µV"},{"name":"10 Hz to 45 Hz","range":"0,2 V to 2 V","cmc":"0,082 % + 0,38 mV"},{"name":"45 Hz to 10 kHz","range":"0,2 V to 2 V","cmc":"0,042 % + 0,29 mV"},{"name":"10 kHz to 20 kHz","range":"0,2 V to 2 V","cmc":"0,12 % + 0,46 mV"},{"name":"20 kHz to 50 kHz","range":"0,2 V to 2 V","cmc":"0,17 % + 0,73 mV"},{"name":"10 Hz to 45 Hz","range":"2 V to 20 V","cmc":"0,084 % + 3,8 mV"},{"name":"45 Hz to 10 kHz","range":"2 V to 20 V","cmc":"0,042 % + 2,7 mV"},{"name":"10 kHz to 20 kHz","range":"2 V to 20 V","cmc":"0,12 % + 4,7 mV"},{"name":"20 kHz to 50 kHz","range":"2 V to 20 V","cmc":"0,17 % + 5,6 mV"},{"name":"30 Hz to 45 Hz","range":"20 V to 200 V","cmc":"0,082 % + 31 mV"},{"name":"45 Hz to 10 kHz","range":"20 V to 200 V","cmc":"0,10 % + 43 mV"},{"name":"10 kHz to 20 kHz","range":"20 V to 200 V","cmc":"0,14 % + 56 mV"},{"name":"20 kHz to 40 kHz","range":"20 V to 200 V","cmc":"0,17 % + 61 mV"},{"name":"30 Hz to 45 Hz","range":"200 V to 1000 V","cmc":"0,082 % + 0,45 V"},{"name":"45 Hz to 1 kHz","range":"200 V to 1000 V","cmc":"0,09 % + 0,28 V"},{"name":"1 kHz to 5 kHz","range":"200 V to 1000 V","cmc":"0,14 % + 0,38 V"},{"name":"5 kHz to 10 kHz","range":"200 V to 1000 V","cmc":"0,16 % + 0,49 V"}],"parameters_zh":[{"name":"10 Hz 至 45 Hz","range":"0,1 mV 至 200 mV","cmc":"0,16 % + 64 µV"},{"name":"45 Hz 至 10 kHz","range":"0,1 mV 至 200 mV","cmc":"0,049 % + 69 µV"},{"name":"10 kHz 至 20 kHz","range":"0,1 mV 至 200 mV","cmc":"0,12 % + 86 µV"},{"name":"20 kHz 至 50 kHz","range":"0,1 mV 至 200 mV","cmc":"0,20 % + 98 µV"},{"name":"10 Hz 至 45 Hz","range":"0,2 V 至 2 V","cmc":"0,082 % + 0,38 mV"},{"name":"45 Hz 至 10 kHz","range":"0,2 V 至 2 V","cmc":"0,042 % + 0,29 mV"},{"name":"10 kHz 至 20 kHz","range":"0,2 V 至 2 V","cmc":"0,12 % + 0,46 mV"},{"name":"20 kHz 至 50 kHz","range":"0,2 V 至 2 V","cmc":"0,17 % + 0,73 mV"},{"name":"10 Hz 至 45 Hz","range":"2 V 至 20 V","cmc":"0,084 % + 3,8 mV"},{"name":"45 Hz 至 10 kHz","range":"2 V 至 20 V","cmc":"0,042 % + 2,7 mV"},{"name":"10 kHz 至 20 kHz","range":"2 V 至 20 V","cmc":"0,12 % + 4,7 mV"},{"name":"20 kHz 至 50 kHz","range":"2 V 至 20 V","cmc":"0,17 % + 5,6 mV"},{"name":"30 Hz 至 45 Hz","range":"20 V 至 200 V","cmc":"0,082 % + 31 mV"},{"name":"45 Hz 至 10 kHz","range":"20 V 至 200 V","cmc":"0,10 % + 43 mV"},{"name":"10 kHz 至 20 kHz","range":"20 V 至 200 V","cmc":"0,14 % + 56 mV"},{"name":"20 kHz 至 40 kHz","range":"20 V 至 200 V","cmc":"0,17 % + 61 mV"},{"name":"30 Hz 至 45 Hz","range":"200 V 至 1000 V","cmc":"0,082 % + 0,45 V"},{"name":"45 Hz 至 1 kHz","range":"200 V 至 1000 V","cmc":"0,09 % + 0,28 V"},{"name":"1 kHz 至 5 kHz","range":"200 V 至 1000 V","cmc":"0,14 % + 0,38 V"},{"name":"5 kHz 至 10 kHz","range":"200 V 至 1000 V","cmc":"0,16 % + 0,49 V"}],"parameters_cs":[{"name":"10 Hz až 45 Hz","range":"0,1 mV až 200 mV","cmc":"0,16 % + 64 µV"},{"name":"45 Hz až 10 kHz","range":"0,1 mV až 200 mV","cmc":"0,049 % + 69 µV"},{"name":"10 kHz až 20 kHz","range":"0,1 mV až 200 mV","cmc":"0,12 % + 86 µV"},{"name":"20 kHz až 50 kHz","range":"0,1 mV až 200 mV","cmc":"0,20 % + 98 µV"},{"name":"10 Hz až 45 Hz","range":"0,2 V až 2 V","cmc":"0,082 % + 0,38 mV"},{"name":"45 Hz až 10 kHz","range":"0,2 V až 2 V","cmc":"0,042 % + 0,29 mV"},{"name":"10 kHz až 20 kHz","range":"0,2 V až 2 V","cmc":"0,12 % + 0,46 mV"},{"name":"20 kHz až 50 kHz","range":"0,2 V až 2 V","cmc":"0,17 % + 0,73 mV"},{"name":"10 Hz až 45 Hz","range":"2 V až 20 V","cmc":"0,084 % + 3,8 mV"},{"name":"45 Hz až 10 kHz","range":"2 V až 20 V","cmc":"0,042 % + 2,7 mV"},{"name":"10 kHz až 20 kHz","range":"2 V až 20 V","cmc":"0,12 % + 4,7 mV"},{"name":"20 kHz až 50 kHz","range":"2 V až 20 V","cmc":"0,17 % + 5,6 mV"},{"name":"30 Hz až 45 Hz","range":"20 V až 200 V","cmc":"0,082 % + 31 mV"},{"name":"45 Hz až 10 kHz","range":"20 V až 200 V","cmc":"0,10 % + 43 mV"},{"name":"10 kHz až 20 kHz","range":"20 V až 200 V","cmc":"0,14 % + 56 mV"},{"name":"20 kHz až 40 kHz","range":"20 V až 200 V","cmc":"0,17 % + 61 mV"},{"name":"30 Hz až 45 Hz","range":"200 V až 1000 V","cmc":"0,082 % + 0,45 V"},{"name":"45 Hz až 1 kHz","range":"200 V až 1000 V","cmc":"0,09 % + 0,28 V"},{"name":"1 kHz až 5 kHz","range":"200 V až 1000 V","cmc":"0,14 % + 0,38 V"},{"name":"5 kHz až 10 kHz","range":"200 V až 1000 V","cmc":"0,16 % + 0,49 V"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a standard calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a standard calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 45 Hz od 0,1 mV do 200 mV CMC 0,16 % + 64 µV\n45 Hz do 10 kHz od 0,1 mV do 200 mV CMC 0,049 % + 69 µV\n10 kHz do 20 kHz od 0,1 mV do 200 mV CMC 0,12 % + 86 µV\n20 kHz do 50 kHz od 0,1 mV do 200 mV CMC 0,20 % + 98 µV\n10 Hz do 45 Hz od 0,2 V do 2 V CMC 0,082 % + 0,38 mV\n45 Hz do 10 kHz od 0,2 V do 2 V CMC 0,042 % + 0,29 mV\n10 kHz do 20 kHz od 0,2 V do 2 V CMC 0,12 % + 0,46 mV\n20 kHz do 50 kHz od 0,2 V do 2 V CMC 0,17 % + 0,73 mV\n10 Hz do 45 Hz od 2 V do 20 V CMC 0,084 % + 3,8 mV\n45 Hz do 10 kHz od 2 V do 20 V CMC 0,042 % + 2,7 mV\n10 kHz do 20 kHz od 2 V do 20 V CMC 0,12 % + 4,7 mV\n20 kHz do 50 kHz od 2 V do 20 V CMC 0,17 % + 5,6 mV\n30 Hz do 45 Hz od 20 V do 200 V CMC 0,082 % + 31 mV\n45 Hz do 10 kHz od 20 V do 200 V CMC 0,10 % + 43 mV\n10 kHz do 20 kHz od 20 V do 200 V CMC 0,14 % + 56 mV\n20 kHz do 40 kHz od 20 V do 200 V CMC 0,17 % + 61 mV\n30 Hz do 45 Hz od 200 V do 1000 V CMC 0,082 % + 0,45 V\n45 Hz do 1 kHz od 200 V do 1000 V CMC 0,09 % + 0,28 V\n1 kHz do 5 kHz od 200 V do 1000 V CMC 0,14 % + 0,38 V\n5 kHz do 10 kHz od 200 V do 1000 V CMC 0,16 % + 0,49 V\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"KP EL1","norm_bases":["KP EL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / mierniki napięcia przemiennego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym 10 Hz do 45 Hz od 0,1 mV do 200 mV CMC 0,16 % + 64 µV 45 Hz do 10 kHz od 0,1 mV do 200 mV CMC 0,049 % + 69 µV 10 kHz do 20 kHz od 0,1 mV do 200 mV CMC 0,12 % + 86 µV 20 kHz do 50 kHz od 0,1 mV do 200 mV CMC 0,20 % + 98 µV 10 Hz do 45 Hz od 0,2 V do 2 V CMC 0,082 % + 0,38 mV 45 Hz do 10 kHz od 0,2 V do 2 V CMC 0,042 % + 0,29 mV 10 kHz do 20 kHz od 0,2 V do 2 V CMC 0,12 % + 0,46 mV 20 kHz do 50 kHz od 0,2 V do 2 V CMC 0,17 % + 0,73 mV 10 Hz do 45 Hz od 2 V do 20 V CMC 0,084 % + 3,8 mV 45 Hz do 10 kHz od 2 V do 20 V CMC 0,042 % + 2,7 mV 10 kHz do 20 kHz od 2 V do 20 V CMC 0,12 % + 4,7 mV 20 kHz do 50 kHz od 2 V do 20 V CMC 0,17 % + 5,6 mV 30 Hz do 45 Hz od 20 V do 200 V CMC 0,082 % + 31 mV 45 Hz do 10 kHz od 20 V do 200 V CMC 0,10 % + 43 mV 10 kHz do 20 kHz od 20 V do 200 V CMC 0,14 % + 56 mV 20 kHz do 40 kHz od 20 V do 200 V CMC 0,17 % + 61 mV 30 Hz do 45 Hz od 200 V do 1000 V CMC 0,082 % + 0,45 V 45 Hz do 1 kHz od 200 V do 1000 V CMC 0,09 % + 0,28 V 1 kHz do 5 kHz od 200 V do 1000 V CMC 0,14 % + 0,38 V 5 kHz do 10 kHz od 200 V do 1000 V CMC 0,16 % + 0,49 V Střídavé napětí / Měřidla střídavého napětí Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 10 Hz až 45 Hz 0,1 mV až 200 mV CMC 0,16 % + 64 µV 45 Hz až 10 kHz 0,1 mV až 200 mV CMC 0,049 % + 69 µV 10 kHz až 20 kHz 0,1 mV až 200 mV CMC 0,12 % + 86 µV 20 kHz až 50 kHz 0,1 mV až 200 mV CMC 0,20 % + 98 µV 10 Hz až 45 Hz 0,2 V až 2 V CMC 0,082 % + 0,38 mV 45 Hz až 10 kHz 0,2 V až 2 V CMC 0,042 % + 0,29 mV 10 kHz až 20 kHz 0,2 V až 2 V CMC 0,12 % + 0,46 mV 20 kHz až 50 kHz 0,2 V až 2 V CMC 0,17 % + 0,73 mV 10 Hz až 45 Hz 2 V až 20 V CMC 0,084 % + 3,8 mV 45 Hz až 10 kHz 2 V až 20 V CMC 0,042 % + 2,7 mV 10 kHz až 20 kHz 2 V až 20 V CMC 0,12 % + 4,7 mV 20 kHz až 50 kHz 2 V až 20 V CMC 0,17 % + 5,6 mV 30 Hz až 45 Hz 20 V až 200 V CMC 0,082 % + 31 mV 45 Hz až 10 kHz 20 V až 200 V CMC 0,10 % + 43 mV 10 kHz až 20 kHz 20 V až 200 V CMC 0,14 % + 56 mV 20 kHz až 40 kHz 20 V až 200 V CMC 0,17 % + 61 mV 30 Hz až 45 Hz 200 V až 1000 V CMC 0,082 % + 0,45 V 45 Hz až 1 kHz 200 V až 1000 V CMC 0,09 % + 0,28 V 1 kHz až 5 kHz 200 V až 1000 V CMC 0,14 % + 0,38 V 5 kHz až 10 kHz 200 V až 1000 V CMC 0,16 % + 0,49 V KP EL1 Napiecie przemienne / mierniki napiecia przemiennego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym 10 Hz do 45 Hz od 0,1 mV do 200 mV CMC 0,16 % + 64 µV 45 Hz do 10 kHz od 0,1 mV do 200 mV CMC 0,049 % + 69 µV 10 kHz do 20 kHz od 0,1 mV do 200 mV CMC 0,12 % + 86 µV 20 kHz do 50 kHz od 0,1 mV do 200 mV CMC 0,20 % + 98 µV 10 Hz do 45 Hz od 0,2 V do 2 V CMC 0,082 % + 0,38 mV 45 Hz do 10 kHz od 0,2 V do 2 V CMC 0,042 % + 0,29 mV 10 kHz do 20 kHz od 0,2 V do 2 V CMC 0,12 % + 0,46 mV 20 kHz do 50 kHz od 0,2 V do 2 V CMC 0,17 % + 0,73 mV 10 Hz do 45 Hz od 2 V do 20 V CMC 0,084 % + 3,8 mV 45 Hz do 10 kHz od 2 V do 20 V CMC 0,042 % + 2,7 mV 10 kHz do 20 kHz od 2 V do 20 V CMC 0,12 % + 4,7 mV 20 kHz do 50 kHz od 2 V do 20 V CMC 0,17 % + 5,6 mV 30 Hz do 45 Hz od 20 V do 200 V CMC 0,082 % + 31 mV 45 Hz do 10 kHz od 20 V do 200 V CMC 0,10 % + 43 mV 10 kHz do 20 kHz od 20 V do 200 V CMC 0,14 % + 56 mV 20 kHz do 40 kHz od 20 V do 200 V CMC 0,17 % + 61 mV 30 Hz do 45 Hz od 200 V do 1000 V CMC 0,082 % + 0,45 V 45 Hz do 1 kHz od 200 V do 1000 V CMC 0,09 % + 0,28 V 1 kHz do 5 kHz od 200 V do 1000 V CMC 0,14 % + 0,38 V 5 kHz do 10 kHz od 200 V do 1000 V CMC 0,16 % + 0,49 V Stridave napeti / Meridla stridaveho napeti Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 10 Hz az 45 Hz 0,1 mV az 200 mV CMC 0,16 % + 64 µV 45 Hz az 10 kHz 0,1 mV az 200 mV CMC 0,049 % + 69 µV 10 kHz az 20 kHz 0,1 mV az 200 mV CMC 0,12 % + 86 µV 20 kHz az 50 kHz 0,1 mV az 200 mV CMC 0,20 % + 98 µV 10 Hz az 45 Hz 0,2 V az 2 V CMC 0,082 % + 0,38 mV 45 Hz az 10 kHz 0,2 V az 2 V CMC 0,042 % + 0,29 mV 10 kHz az 20 kHz 0,2 V az 2 V CMC 0,12 % + 0,46 mV 20 kHz az 50 kHz 0,2 V az 2 V CMC 0,17 % + 0,73 mV 10 Hz az 45 Hz 2 V az 20 V CMC 0,084 % + 3,8 mV 45 Hz az 10 kHz 2 V az 20 V CMC 0,042 % + 2,7 mV 10 kHz az 20 kHz 2 V az 20 V CMC 0,12 % + 4,7 mV 20 kHz az 50 kHz 2 V az 20 V CMC 0,17 % + 5,6 mV 30 Hz az 45 Hz 20 V az 200 V CMC 0,082 % + 31 mV 45 Hz az 10 kHz 20 V az 200 V CMC 0,10 % + 43 mV 10 kHz az 20 kHz 20 V az 200 V CMC 0,14 % + 56 mV 20 kHz az 40 kHz 20 V az 200 V CMC 0,17 % + 61 mV 30 Hz az 45 Hz 200 V az 1000 V CMC 0,082 % + 0,45 V 45 Hz az 1 kHz 200 V az 1000 V CMC 0,09 % + 0,28 V 1 kHz az 5 kHz 200 V az 1000 V CMC 0,14 % + 0,38 V 5 kHz az 10 kHz 200 V az 1000 V CMC 0,16 % + 0,49 V KP EL1","search_en":"AC voltage / AC voltage meters Calibration – electrical quantities Direct generation with a standard calibrator 10 Hz to 45 Hz 0,1 mV to 200 mV CMC 0,16 % + 64 µV 45 Hz to 10 kHz 0,1 mV to 200 mV CMC 0,049 % + 69 µV 10 kHz to 20 kHz 0,1 mV to 200 mV CMC 0,12 % + 86 µV 20 kHz to 50 kHz 0,1 mV to 200 mV CMC 0,20 % + 98 µV 10 Hz to 45 Hz 0,2 V to 2 V CMC 0,082 % + 0,38 mV 45 Hz to 10 kHz 0,2 V to 2 V CMC 0,042 % + 0,29 mV 10 kHz to 20 kHz 0,2 V to 2 V CMC 0,12 % + 0,46 mV 20 kHz to 50 kHz 0,2 V to 2 V CMC 0,17 % + 0,73 mV 10 Hz to 45 Hz 2 V to 20 V CMC 0,084 % + 3,8 mV 45 Hz to 10 kHz 2 V to 20 V CMC 0,042 % + 2,7 mV 10 kHz to 20 kHz 2 V to 20 V CMC 0,12 % + 4,7 mV 20 kHz to 50 kHz 2 V to 20 V CMC 0,17 % + 5,6 mV 30 Hz to 45 Hz 20 V to 200 V CMC 0,082 % + 31 mV 45 Hz to 10 kHz 20 V to 200 V CMC 0,10 % + 43 mV 10 kHz to 20 kHz 20 V to 200 V CMC 0,14 % + 56 mV 20 kHz to 40 kHz 20 V to 200 V CMC 0,17 % + 61 mV 30 Hz to 45 Hz 200 V to 1000 V CMC 0,082 % + 0,45 V 45 Hz to 1 kHz 200 V to 1000 V CMC 0,09 % + 0,28 V 1 kHz to 5 kHz 200 V to 1000 V CMC 0,14 % + 0,38 V 5 kHz to 10 kHz 200 V to 1000 V CMC 0,16 % + 0,49 V KP EL1","search_zh":"交流电压 / 交流电压测量仪器 校准 – 电学量 用标准校准器直接产生 10 Hz 至 45 Hz 0,1 mV 至 200 mV CMC 0,16 % + 64 µV 45 Hz 至 10 kHz 0,1 mV 至 200 mV CMC 0,049 % + 69 µV 10 kHz 至 20 kHz 0,1 mV 至 200 mV CMC 0,12 % + 86 µV 20 kHz 至 50 kHz 0,1 mV 至 200 mV CMC 0,20 % + 98 µV 10 Hz 至 45 Hz 0,2 V 至 2 V CMC 0,082 % + 0,38 mV 45 Hz 至 10 kHz 0,2 V 至 2 V CMC 0,042 % + 0,29 mV 10 kHz 至 20 kHz 0,2 V 至 2 V CMC 0,12 % + 0,46 mV 20 kHz 至 50 kHz 0,2 V 至 2 V CMC 0,17 % + 0,73 mV 10 Hz 至 45 Hz 2 V 至 20 V CMC 0,084 % + 3,8 mV 45 Hz 至 10 kHz 2 V 至 20 V CMC 0,042 % + 2,7 mV 10 kHz 至 20 kHz 2 V 至 20 V CMC 0,12 % + 4,7 mV 20 kHz 至 50 kHz 2 V 至 20 V CMC 0,17 % + 5,6 mV 30 Hz 至 45 Hz 20 V 至 200 V CMC 0,082 % + 31 mV 45 Hz 至 10 kHz 20 V 至 200 V CMC 0,10 % + 43 mV 10 kHz 至 20 kHz 20 V 至 200 V CMC 0,14 % + 56 mV 20 kHz 至 40 kHz 20 V 至 200 V CMC 0,17 % + 61 mV 30 Hz 至 45 Hz 200 V 至 1000 V CMC 0,082 % + 0,45 V 45 Hz 至 1 kHz 200 V 至 1000 V CMC 0,09 % + 0,28 V 1 kHz 至 5 kHz 200 V 至 1000 V CMC 0,14 % + 0,38 V 5 kHz 至 10 kHz 200 V 至 1000 V CMC 0,16 % + 0,49 V KP EL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ddb45b69dfcd605986b41be4","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / źródła prądu przemiennego","test_object_en":"Alternating current / Alternating current sources","test_object_zh":"交流电流 / 交流电流源","test_object_cs":"Střídavý proud / Zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 1 kHz","range":"od 0,1 µA do 100 µA","cmc":"0,15 % + 7,3 nA"},{"name":"10 Hz do 5 kHz","range":"od 0,1 mA do 1 mA","cmc":"0,10 % + 0,51 µA"},{"name":"10 Hz do 5 kHz","range":"od 1 mA do 10 mA","cmc":"0,10 % + 5,1 µA"},{"name":"10 Hz do 5 kHz","range":"od 10 mA do 100 mA","cmc":"0,10 % + 51 µA"},{"name":"10 Hz do 5 kHz","range":"od 0,1 A do 1 A","cmc":"0,10 % + 0,51 mA"},{"name":"10 Hz do 5 kHz","range":"od 1 A do 3 A","cmc":"0,15 % + 3,4 mA"}],"parameters_en":[{"name":"10 Hz to 1 kHz","range":"0,1 µA to 100 µA","cmc":"0,15 % + 7,3 nA"},{"name":"10 Hz to 5 kHz","range":"0,1 mA to 1 mA","cmc":"0,10 % + 0,51 µA"},{"name":"10 Hz to 5 kHz","range":"1 mA to 10 mA","cmc":"0,10 % + 5,1 µA"},{"name":"10 Hz to 5 kHz","range":"10 mA to 100 mA","cmc":"0,10 % + 51 µA"},{"name":"10 Hz to 5 kHz","range":"0,1 A to 1 A","cmc":"0,10 % + 0,51 mA"},{"name":"10 Hz to 5 kHz","range":"1 A to 3 A","cmc":"0,15 % + 3,4 mA"}],"parameters_zh":[{"name":"10 Hz 至 1 kHz","range":"0,1 µA 至 100 µA","cmc":"0,15 % + 7,3 nA"},{"name":"10 Hz 至 5 kHz","range":"0,1 mA 至 1 mA","cmc":"0,10 % + 0,51 µA"},{"name":"10 Hz 至 5 kHz","range":"1 mA 至 10 mA","cmc":"0,10 % + 5,1 µA"},{"name":"10 Hz 至 5 kHz","range":"10 mA 至 100 mA","cmc":"0,10 % + 51 µA"},{"name":"10 Hz 至 5 kHz","range":"0,1 A 至 1 A","cmc":"0,10 % + 0,51 mA"},{"name":"10 Hz 至 5 kHz","range":"1 A 至 3 A","cmc":"0,15 % + 3,4 mA"}],"parameters_cs":[{"name":"10 Hz až 1 kHz","range":"0,1 µA až 100 µA","cmc":"0,15 % + 7,3 nA"},{"name":"10 Hz až 5 kHz","range":"0,1 mA až 1 mA","cmc":"0,10 % + 0,51 µA"},{"name":"10 Hz až 5 kHz","range":"1 mA až 10 mA","cmc":"0,10 % + 5,1 µA"},{"name":"10 Hz až 5 kHz","range":"10 mA až 100 mA","cmc":"0,10 % + 51 µA"},{"name":"10 Hz až 5 kHz","range":"0,1 A až 1 A","cmc":"0,10 % + 0,51 mA"},{"name":"10 Hz až 5 kHz","range":"1 A až 3 A","cmc":"0,15 % + 3,4 mA"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 1 kHz od 0,1 µA do 100 µA CMC 0,15 % + 7,3 nA\n10 Hz do 5 kHz od 0,1 mA do 1 mA CMC 0,10 % + 0,51 µA\n10 Hz do 5 kHz od 1 mA do 10 mA CMC 0,10 % + 5,1 µA\n10 Hz do 5 kHz od 10 mA do 100 mA CMC 0,10 % + 51 µA\n10 Hz do 5 kHz od 0,1 A do 1 A CMC 0,10 % + 0,51 mA\n10 Hz do 5 kHz od 1 A do 3 A CMC 0,15 % + 3,4 mA\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP EL2","norm_bases":["KP EL2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 10 Hz do 1 kHz od 0,1 µA do 100 µA CMC 0,15 % + 7,3 nA 10 Hz do 5 kHz od 0,1 mA do 1 mA CMC 0,10 % + 0,51 µA 10 Hz do 5 kHz od 1 mA do 10 mA CMC 0,10 % + 5,1 µA 10 Hz do 5 kHz od 10 mA do 100 mA CMC 0,10 % + 51 µA 10 Hz do 5 kHz od 0,1 A do 1 A CMC 0,10 % + 0,51 mA 10 Hz do 5 kHz od 1 A do 3 A CMC 0,15 % + 3,4 mA Střídavý proud / Zdroje střídavého proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 10 Hz až 1 kHz 0,1 µA až 100 µA CMC 0,15 % + 7,3 nA 10 Hz až 5 kHz 0,1 mA až 1 mA CMC 0,10 % + 0,51 µA 10 Hz až 5 kHz 1 mA až 10 mA CMC 0,10 % + 5,1 µA 10 Hz až 5 kHz 10 mA až 100 mA CMC 0,10 % + 51 µA 10 Hz až 5 kHz 0,1 A až 1 A CMC 0,10 % + 0,51 mA 10 Hz až 5 kHz 1 A až 3 A CMC 0,15 % + 3,4 mA KP EL2 Prad przemienny / zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 10 Hz do 1 kHz od 0,1 µA do 100 µA CMC 0,15 % + 7,3 nA 10 Hz do 5 kHz od 0,1 mA do 1 mA CMC 0,10 % + 0,51 µA 10 Hz do 5 kHz od 1 mA do 10 mA CMC 0,10 % + 5,1 µA 10 Hz do 5 kHz od 10 mA do 100 mA CMC 0,10 % + 51 µA 10 Hz do 5 kHz od 0,1 A do 1 A CMC 0,10 % + 0,51 mA 10 Hz do 5 kHz od 1 A do 3 A CMC 0,15 % + 3,4 mA Stridavy proud / Zdroje stridaveho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 10 Hz az 1 kHz 0,1 µA az 100 µA CMC 0,15 % + 7,3 nA 10 Hz az 5 kHz 0,1 mA az 1 mA CMC 0,10 % + 0,51 µA 10 Hz az 5 kHz 1 mA az 10 mA CMC 0,10 % + 5,1 µA 10 Hz az 5 kHz 10 mA az 100 mA CMC 0,10 % + 51 µA 10 Hz az 5 kHz 0,1 A az 1 A CMC 0,10 % + 0,51 mA 10 Hz az 5 kHz 1 A az 3 A CMC 0,15 % + 3,4 mA KP EL2","search_en":"Alternating current / Alternating current sources Calibration – electrical quantities Direct measurement by a standard multimeter 10 Hz to 1 kHz 0,1 µA to 100 µA CMC 0,15 % + 7,3 nA 10 Hz to 5 kHz 0,1 mA to 1 mA CMC 0,10 % + 0,51 µA 10 Hz to 5 kHz 1 mA to 10 mA CMC 0,10 % + 5,1 µA 10 Hz to 5 kHz 10 mA to 100 mA CMC 0,10 % + 51 µA 10 Hz to 5 kHz 0,1 A to 1 A CMC 0,10 % + 0,51 mA 10 Hz to 5 kHz 1 A to 3 A CMC 0,15 % + 3,4 mA KP EL2","search_zh":"交流电流 / 交流电流源 校准 – 电学量 用标准万用表直接测量 10 Hz 至 1 kHz 0,1 µA 至 100 µA CMC 0,15 % + 7,3 nA 10 Hz 至 5 kHz 0,1 mA 至 1 mA CMC 0,10 % + 0,51 µA 10 Hz 至 5 kHz 1 mA 至 10 mA CMC 0,10 % + 5,1 µA 10 Hz 至 5 kHz 10 mA 至 100 mA CMC 0,10 % + 51 µA 10 Hz 至 5 kHz 0,1 A 至 1 A CMC 0,10 % + 0,51 mA 10 Hz 至 5 kHz 1 A 至 3 A CMC 0,15 % + 3,4 mA KP EL2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"94b3f652fd15323034fbcf2b","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"8","test_object":"Prąd przemienny / mierniki prądu przemiennego","test_object_en":"Alternating current / Alternating current meters","test_object_zh":"交流电流 / 交流电流测量仪器","test_object_cs":"Střídavý proud / Měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 45 Hz","range":"od 20 µA do 200 µA","cmc":"0,25 % + 0,40 µA"},{"name":"45 Hz do 1 kHz","range":"od 20 µA do 200 µA","cmc":"0,08 % + 0,30 µA"},{"name":"10 Hz do 45 Hz","range":"od 0,2 mA do 2 mA","cmc":"0,23 % + 0,40 µA"},{"name":"45 Hz do 1 kHz","range":"od 0,2 mA do 2 mA","cmc":"0,06 % + 0,30 µA"},{"name":"10 Hz do 45 Hz","range":"od 2 mA do 20 mA","cmc":"0,23 % + 4,5 µA"},{"name":"45 Hz do 1 kHz","range":"od 2 mA do 20 mA","cmc":"0,05 % + 3,0 µA"},{"name":"10 Hz do 45 Hz","range":"od 20 mA do 200 mA","cmc":"0,23 % + 45 µA"},{"name":"45 Hz do 1 kHz","range":"od 20 mA do 200 mA","cmc":"0,05 % + 30 µA"},{"name":"10 Hz do 45 Hz","range":"od 0,2 A do 2 A","cmc":"0,23 % + 0,45 mA"},{"name":"45 Hz do 1 kHz","range":"od 0,2 A do 2 A","cmc":"0,06 % + 0,30 mA"},{"name":"30 Hz do 45 Hz","range":"od 2 A do 30 A","cmc":"0,23 % + 4,5 mA"},{"name":"45 Hz do 100 Hz","range":"od 2 A do 30 A","cmc":"0,06 % + 3,0 mA"},{"name":"100 Hz do 1 kHz","range":"od 2 A do 30 A","cmc":"0,60 % + 5,8 mA"}],"parameters_en":[{"name":"10 Hz to 45 Hz","range":"20 µA to 200 µA","cmc":"0,25 % + 0,40 µA"},{"name":"45 Hz to 1 kHz","range":"20 µA to 200 µA","cmc":"0,08 % + 0,30 µA"},{"name":"10 Hz to 45 Hz","range":"0,2 mA to 2 mA","cmc":"0,23 % + 0,40 µA"},{"name":"45 Hz to 1 kHz","range":"0,2 mA to 2 mA","cmc":"0,06 % + 0,30 µA"},{"name":"10 Hz to 45 Hz","range":"2 mA to 20 mA","cmc":"0,23 % + 4,5 µA"},{"name":"45 Hz to 1 kHz","range":"2 mA to 20 mA","cmc":"0,05 % + 3,0 µA"},{"name":"10 Hz to 45 Hz","range":"20 mA to 200 mA","cmc":"0,23 % + 45 µA"},{"name":"45 Hz to 1 kHz","range":"20 mA to 200 mA","cmc":"0,05 % + 30 µA"},{"name":"10 Hz to 45 Hz","range":"0,2 A to 2 A","cmc":"0,23 % + 0,45 mA"},{"name":"45 Hz to 1 kHz","range":"0,2 A to 2 A","cmc":"0,06 % + 0,30 mA"},{"name":"30 Hz to 45 Hz","range":"2 A to 30 A","cmc":"0,23 % + 4,5 mA"},{"name":"45 Hz to 100 Hz","range":"2 A to 30 A","cmc":"0,06 % + 3,0 mA"},{"name":"100 Hz to 1 kHz","range":"2 A to 30 A","cmc":"0,60 % + 5,8 mA"}],"parameters_zh":[{"name":"10 Hz 至 45 Hz","range":"20 µA 至 200 µA","cmc":"0,25 % + 0,40 µA"},{"name":"45 Hz 至 1 kHz","range":"20 µA 至 200 µA","cmc":"0,08 % + 0,30 µA"},{"name":"10 Hz 至 45 Hz","range":"0,2 mA 至 2 mA","cmc":"0,23 % + 0,40 µA"},{"name":"45 Hz 至 1 kHz","range":"0,2 mA 至 2 mA","cmc":"0,06 % + 0,30 µA"},{"name":"10 Hz 至 45 Hz","range":"2 mA 至 20 mA","cmc":"0,23 % + 4,5 µA"},{"name":"45 Hz 至 1 kHz","range":"2 mA 至 20 mA","cmc":"0,05 % + 3,0 µA"},{"name":"10 Hz 至 45 Hz","range":"20 mA 至 200 mA","cmc":"0,23 % + 45 µA"},{"name":"45 Hz 至 1 kHz","range":"20 mA 至 200 mA","cmc":"0,05 % + 30 µA"},{"name":"10 Hz 至 45 Hz","range":"0,2 A 至 2 A","cmc":"0,23 % + 0,45 mA"},{"name":"45 Hz 至 1 kHz","range":"0,2 A 至 2 A","cmc":"0,06 % + 0,30 mA"},{"name":"30 Hz 至 45 Hz","range":"2 A 至 30 A","cmc":"0,23 % + 4,5 mA"},{"name":"45 Hz 至 100 Hz","range":"2 A 至 30 A","cmc":"0,06 % + 3,0 mA"},{"name":"100 Hz 至 1 kHz","range":"2 A 至 30 A","cmc":"0,60 % + 5,8 mA"}],"parameters_cs":[{"name":"10 Hz až 45 Hz","range":"20 µA až 200 µA","cmc":"0,25 % + 0,40 µA"},{"name":"45 Hz až 1 kHz","range":"20 µA až 200 µA","cmc":"0,08 % + 0,30 µA"},{"name":"10 Hz až 45 Hz","range":"0,2 mA až 2 mA","cmc":"0,23 % + 0,40 µA"},{"name":"45 Hz až 1 kHz","range":"0,2 mA až 2 mA","cmc":"0,06 % + 0,30 µA"},{"name":"10 Hz až 45 Hz","range":"2 mA až 20 mA","cmc":"0,23 % + 4,5 µA"},{"name":"45 Hz až 1 kHz","range":"2 mA až 20 mA","cmc":"0,05 % + 3,0 µA"},{"name":"10 Hz až 45 Hz","range":"20 mA až 200 mA","cmc":"0,23 % + 45 µA"},{"name":"45 Hz až 1 kHz","range":"20 mA až 200 mA","cmc":"0,05 % + 30 µA"},{"name":"10 Hz až 45 Hz","range":"0,2 A až 2 A","cmc":"0,23 % + 0,45 mA"},{"name":"45 Hz až 1 kHz","range":"0,2 A až 2 A","cmc":"0,06 % + 0,30 mA"},{"name":"30 Hz až 45 Hz","range":"2 A až 30 A","cmc":"0,23 % + 4,5 mA"},{"name":"45 Hz až 100 Hz","range":"2 A až 30 A","cmc":"0,06 % + 3,0 mA"},{"name":"100 Hz až 1 kHz","range":"2 A až 30 A","cmc":"0,60 % + 5,8 mA"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a standard calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a standard calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 45 Hz od 20 µA do 200 µA CMC 0,25 % + 0,40 µA\n45 Hz do 1 kHz od 20 µA do 200 µA CMC 0,08 % + 0,30 µA\n10 Hz do 45 Hz od 0,2 mA do 2 mA CMC 0,23 % + 0,40 µA\n45 Hz do 1 kHz od 0,2 mA do 2 mA CMC 0,06 % + 0,30 µA\n10 Hz do 45 Hz od 2 mA do 20 mA CMC 0,23 % + 4,5 µA\n45 Hz do 1 kHz od 2 mA do 20 mA CMC 0,05 % + 3,0 µA\n10 Hz do 45 Hz od 20 mA do 200 mA CMC 0,23 % + 45 µA\n45 Hz do 1 kHz od 20 mA do 200 mA CMC 0,05 % + 30 µA\n10 Hz do 45 Hz od 0,2 A do 2 A CMC 0,23 % + 0,45 mA\n45 Hz do 1 kHz od 0,2 A do 2 A CMC 0,06 % + 0,30 mA\n30 Hz do 45 Hz od 2 A do 30 A CMC 0,23 % + 4,5 mA\n45 Hz do 100 Hz od 2 A do 30 A CMC 0,06 % + 3,0 mA\n100 Hz do 1 kHz od 2 A do 30 A CMC 0,60 % + 5,8 mA\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"KP EL1","norm_bases":["KP EL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki prądu przemiennego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym 10 Hz do 45 Hz od 20 µA do 200 µA CMC 0,25 % + 0,40 µA 45 Hz do 1 kHz od 20 µA do 200 µA CMC 0,08 % + 0,30 µA 10 Hz do 45 Hz od 0,2 mA do 2 mA CMC 0,23 % + 0,40 µA 45 Hz do 1 kHz od 0,2 mA do 2 mA CMC 0,06 % + 0,30 µA 10 Hz do 45 Hz od 2 mA do 20 mA CMC 0,23 % + 4,5 µA 45 Hz do 1 kHz od 2 mA do 20 mA CMC 0,05 % + 3,0 µA 10 Hz do 45 Hz od 20 mA do 200 mA CMC 0,23 % + 45 µA 45 Hz do 1 kHz od 20 mA do 200 mA CMC 0,05 % + 30 µA 10 Hz do 45 Hz od 0,2 A do 2 A CMC 0,23 % + 0,45 mA 45 Hz do 1 kHz od 0,2 A do 2 A CMC 0,06 % + 0,30 mA 30 Hz do 45 Hz od 2 A do 30 A CMC 0,23 % + 4,5 mA 45 Hz do 100 Hz od 2 A do 30 A CMC 0,06 % + 3,0 mA 100 Hz do 1 kHz od 2 A do 30 A CMC 0,60 % + 5,8 mA Střídavý proud / Měřidla střídavého proudu Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 10 Hz až 45 Hz 20 µA až 200 µA CMC 0,25 % + 0,40 µA 45 Hz až 1 kHz 20 µA až 200 µA CMC 0,08 % + 0,30 µA 10 Hz až 45 Hz 0,2 mA až 2 mA CMC 0,23 % + 0,40 µA 45 Hz až 1 kHz 0,2 mA až 2 mA CMC 0,06 % + 0,30 µA 10 Hz až 45 Hz 2 mA až 20 mA CMC 0,23 % + 4,5 µA 45 Hz až 1 kHz 2 mA až 20 mA CMC 0,05 % + 3,0 µA 10 Hz až 45 Hz 20 mA až 200 mA CMC 0,23 % + 45 µA 45 Hz až 1 kHz 20 mA až 200 mA CMC 0,05 % + 30 µA 10 Hz až 45 Hz 0,2 A až 2 A CMC 0,23 % + 0,45 mA 45 Hz až 1 kHz 0,2 A až 2 A CMC 0,06 % + 0,30 mA 30 Hz až 45 Hz 2 A až 30 A CMC 0,23 % + 4,5 mA 45 Hz až 100 Hz 2 A až 30 A CMC 0,06 % + 3,0 mA 100 Hz až 1 kHz 2 A až 30 A CMC 0,60 % + 5,8 mA KP EL1 Prad przemienny / mierniki pradu przemiennego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym 10 Hz do 45 Hz od 20 µA do 200 µA CMC 0,25 % + 0,40 µA 45 Hz do 1 kHz od 20 µA do 200 µA CMC 0,08 % + 0,30 µA 10 Hz do 45 Hz od 0,2 mA do 2 mA CMC 0,23 % + 0,40 µA 45 Hz do 1 kHz od 0,2 mA do 2 mA CMC 0,06 % + 0,30 µA 10 Hz do 45 Hz od 2 mA do 20 mA CMC 0,23 % + 4,5 µA 45 Hz do 1 kHz od 2 mA do 20 mA CMC 0,05 % + 3,0 µA 10 Hz do 45 Hz od 20 mA do 200 mA CMC 0,23 % + 45 µA 45 Hz do 1 kHz od 20 mA do 200 mA CMC 0,05 % + 30 µA 10 Hz do 45 Hz od 0,2 A do 2 A CMC 0,23 % + 0,45 mA 45 Hz do 1 kHz od 0,2 A do 2 A CMC 0,06 % + 0,30 mA 30 Hz do 45 Hz od 2 A do 30 A CMC 0,23 % + 4,5 mA 45 Hz do 100 Hz od 2 A do 30 A CMC 0,06 % + 3,0 mA 100 Hz do 1 kHz od 2 A do 30 A CMC 0,60 % + 5,8 mA Stridavy proud / Meridla stridaveho proudu Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 10 Hz az 45 Hz 20 µA az 200 µA CMC 0,25 % + 0,40 µA 45 Hz az 1 kHz 20 µA az 200 µA CMC 0,08 % + 0,30 µA 10 Hz az 45 Hz 0,2 mA az 2 mA CMC 0,23 % + 0,40 µA 45 Hz az 1 kHz 0,2 mA az 2 mA CMC 0,06 % + 0,30 µA 10 Hz az 45 Hz 2 mA az 20 mA CMC 0,23 % + 4,5 µA 45 Hz az 1 kHz 2 mA az 20 mA CMC 0,05 % + 3,0 µA 10 Hz az 45 Hz 20 mA az 200 mA CMC 0,23 % + 45 µA 45 Hz az 1 kHz 20 mA az 200 mA CMC 0,05 % + 30 µA 10 Hz az 45 Hz 0,2 A az 2 A CMC 0,23 % + 0,45 mA 45 Hz az 1 kHz 0,2 A az 2 A CMC 0,06 % + 0,30 mA 30 Hz az 45 Hz 2 A az 30 A CMC 0,23 % + 4,5 mA 45 Hz az 100 Hz 2 A az 30 A CMC 0,06 % + 3,0 mA 100 Hz az 1 kHz 2 A az 30 A CMC 0,60 % + 5,8 mA KP EL1","search_en":"Alternating current / Alternating current meters Calibration – electrical quantities Direct generation with a standard calibrator 10 Hz to 45 Hz 20 µA to 200 µA CMC 0,25 % + 0,40 µA 45 Hz to 1 kHz 20 µA to 200 µA CMC 0,08 % + 0,30 µA 10 Hz to 45 Hz 0,2 mA to 2 mA CMC 0,23 % + 0,40 µA 45 Hz to 1 kHz 0,2 mA to 2 mA CMC 0,06 % + 0,30 µA 10 Hz to 45 Hz 2 mA to 20 mA CMC 0,23 % + 4,5 µA 45 Hz to 1 kHz 2 mA to 20 mA CMC 0,05 % + 3,0 µA 10 Hz to 45 Hz 20 mA to 200 mA CMC 0,23 % + 45 µA 45 Hz to 1 kHz 20 mA to 200 mA CMC 0,05 % + 30 µA 10 Hz to 45 Hz 0,2 A to 2 A CMC 0,23 % + 0,45 mA 45 Hz to 1 kHz 0,2 A to 2 A CMC 0,06 % + 0,30 mA 30 Hz to 45 Hz 2 A to 30 A CMC 0,23 % + 4,5 mA 45 Hz to 100 Hz 2 A to 30 A CMC 0,06 % + 3,0 mA 100 Hz to 1 kHz 2 A to 30 A CMC 0,60 % + 5,8 mA KP EL1","search_zh":"交流电流 / 交流电流测量仪器 校准 – 电学量 用标准校准器直接产生 10 Hz 至 45 Hz 20 µA 至 200 µA CMC 0,25 % + 0,40 µA 45 Hz 至 1 kHz 20 µA 至 200 µA CMC 0,08 % + 0,30 µA 10 Hz 至 45 Hz 0,2 mA 至 2 mA CMC 0,23 % + 0,40 µA 45 Hz 至 1 kHz 0,2 mA 至 2 mA CMC 0,06 % + 0,30 µA 10 Hz 至 45 Hz 2 mA 至 20 mA CMC 0,23 % + 4,5 µA 45 Hz 至 1 kHz 2 mA 至 20 mA CMC 0,05 % + 3,0 µA 10 Hz 至 45 Hz 20 mA 至 200 mA CMC 0,23 % + 45 µA 45 Hz 至 1 kHz 20 mA 至 200 mA CMC 0,05 % + 30 µA 10 Hz 至 45 Hz 0,2 A 至 2 A CMC 0,23 % + 0,45 mA 45 Hz 至 1 kHz 0,2 A 至 2 A CMC 0,06 % + 0,30 mA 30 Hz 至 45 Hz 2 A 至 30 A CMC 0,23 % + 4,5 mA 45 Hz 至 100 Hz 2 A 至 30 A CMC 0,06 % + 3,0 mA 100 Hz 至 1 kHz 2 A 至 30 A CMC 0,60 % + 5,8 mA KP EL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43ea8e0032ed3263a4147aeb","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"8","test_object":"Prąd przemienny / mierniki prądu przemiennego","test_object_en":"Alternating current / Alternating current meters","test_object_zh":"交流电流 / 交流电流测量仪器","test_object_cs":"Střídavý proud / Měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"30 Hz do 60 Hz","range":"od 30 A do 1500 A","cmc":"0,42 % + 0,13 A"}],"parameters_en":[{"name":"30 Hz to 60 Hz","range":"30 A to 1500 A","cmc":"0,42 % + 0,13 A"}],"parameters_zh":[{"name":"30 Hz 至 60 Hz","range":"30 A 至 1500 A","cmc":"0,42 % + 0,13 A"}],"parameters_cs":[{"name":"30 Hz až 60 Hz","range":"30 A až 1500 A","cmc":"0,42 % + 0,13 A"}],"technique":"Symulacja za pomocą cewki prądowej","technique_en":"Simulation using current coil","technique_zh":"用电流线圈模拟","technique_cs":"Simulace pomocí proudové cívky","techniques":["Symulacja za pomocą cewki prądowej"],"techniques_en":["Simulation using current coil"],"techniques_zh":["用电流线圈模拟"],"techniques_cs":["Simulace pomocí proudové cívky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n30 Hz do 60 Hz od 30 A do 1500 A CMC 0,42 % + 0,13 A\nSymulacja za pomocą cewki prądowej","reference":"KP EL1","norm_bases":["KP EL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki prądu przemiennego Wzorcowanie – wielkości elektryczne Symulacja za pomocą cewki prądowej 30 Hz do 60 Hz od 30 A do 1500 A CMC 0,42 % + 0,13 A Střídavý proud / Měřidla střídavého proudu Kalibrace – elektrické veličiny Simulace pomocí proudové cívky 30 Hz až 60 Hz 30 A až 1500 A CMC 0,42 % + 0,13 A KP EL1 Prad przemienny / mierniki pradu przemiennego Wzorcowanie – wielkosci elektryczne Symulacja za pomoca cewki pradowej 30 Hz do 60 Hz od 30 A do 1500 A CMC 0,42 % + 0,13 A Stridavy proud / Meridla stridaveho proudu Kalibrace – elektricke veliciny Simulace pomoci proudove civky 30 Hz az 60 Hz 30 A az 1500 A CMC 0,42 % + 0,13 A KP EL1","search_en":"Alternating current / Alternating current meters Calibration – electrical quantities Simulation using current coil 30 Hz to 60 Hz 30 A to 1500 A CMC 0,42 % + 0,13 A KP EL1","search_zh":"交流电流 / 交流电流测量仪器 校准 – 电学量 用电流线圈模拟 30 Hz 至 60 Hz 30 A 至 1500 A CMC 0,42 % + 0,13 A KP EL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8e16835ed37f24635f7a278b","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"9","test_object":"Rezystancja przy prądzie stałym / mierniki rezystancji","test_object_en":"DC resistance / DC resistance meters","test_object_zh":"直流电阻 / 直流电阻测量仪器","test_object_cs":"Stejnosměrný odpor / Měřidla stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0,1 Ω","cmc":"8,7 mΩ"},{"name":"","range":"1 Ω","cmc":"8,9 mΩ"},{"name":"","range":"10 Ω","cmc":"11 mΩ"},{"name":"","range":"100 Ω","cmc":"20 mΩ"},{"name":"","range":"1 kΩ","cmc":"0,16 Ω"},{"name":"","range":"10 kΩ","cmc":"1,6 Ω"},{"name":"","range":"100 kΩ","cmc":"15 Ω"},{"name":"","range":"1 MΩ","cmc":"0,29 kΩ"},{"name":"","range":"10 MΩ","cmc":"8,0 kΩ"},{"name":"","range":"100 MΩ","cmc":"0,98 MΩ"},{"name":"","range":"1 GΩ","cmc":"22 MΩ"},{"name":"","range":"od 0 Ω do 100 Ω","cmc":"0,018 % + 88 mΩ"},{"name":"","range":"od 100 Ω do 330 Ω","cmc":"0,012 % + 0,11 Ω"},{"name":"","range":"od 330 Ω do 1 kΩ","cmc":"0,01 % + 0,19 Ω"},{"name":"","range":"od 1 kΩ do 3,3 kΩ","cmc":"0,012 % + 0,29 Ω"},{"name":"","range":"od 3,3 kΩ do 10 kΩ","cmc":"0,0082 % + 1,4 Ω"},{"name":"","range":"od 10 kΩ do 33 kΩ","cmc":"0,012 % + 2,2 Ω"},{"name":"","range":"od 33 kΩ do 100 kΩ","cmc":"0,0066 % + 18 Ω"},{"name":"","range":"od 100 kΩ do 330 kΩ","cmc":"0,011 % + 24 Ω"},{"name":"","range":"od 330 kΩ do 1 MΩ","cmc":"0,0066 % + 0,18 kΩ"},{"name":"","range":"od 1 MΩ do 3,3 MΩ","cmc":"0,013 % + 0,24 kΩ"},{"name":"","range":"od 3,3 MΩ do 10 MΩ","cmc":"0,0075 % + 1,8 kΩ"},{"name":"","range":"od 10 MΩ do 33 MΩ","cmc":"0,052 % + 6,4 kΩ"},{"name":"","range":"od 33 MΩ do 100 MΩ","cmc":"0,064 % + 0,21 MΩ"},{"name":"","range":"od 100 MΩ do 330 MΩ","cmc":"1,3 % + 1,9 MΩ"},{"name":"","range":"od 330 MΩ do 1 GΩ","cmc":"2,4 % + 13 MΩ"}],"parameters_en":[{"name":"","range":"0,1 Ω","cmc":"8,7 mΩ"},{"name":"","range":"1 Ω","cmc":"8,9 mΩ"},{"name":"","range":"10 Ω","cmc":"11 mΩ"},{"name":"","range":"100 Ω","cmc":"20 mΩ"},{"name":"","range":"1 kΩ","cmc":"0,16 Ω"},{"name":"","range":"10 kΩ","cmc":"1,6 Ω"},{"name":"","range":"100 kΩ","cmc":"15 Ω"},{"name":"","range":"1 MΩ","cmc":"0,29 kΩ"},{"name":"","range":"10 MΩ","cmc":"8,0 kΩ"},{"name":"","range":"100 MΩ","cmc":"0,98 MΩ"},{"name":"","range":"1 GΩ","cmc":"22 MΩ"},{"name":"","range":"0 Ω to 100 Ω","cmc":"0,018 % + 88 mΩ"},{"name":"","range":"100 Ω to 330 Ω","cmc":"0,012 % + 0,11 Ω"},{"name":"","range":"330 Ω to 1 kΩ","cmc":"0,01 % + 0,19 Ω"},{"name":"","range":"1 kΩ to 3,3 kΩ","cmc":"0,012 % + 0,29 Ω"},{"name":"","range":"3,3 kΩ to 10 kΩ","cmc":"0,0082 % + 1,4 Ω"},{"name":"","range":"10 kΩ to 33 kΩ","cmc":"0,012 % + 2,2 Ω"},{"name":"","range":"33 kΩ to 100 kΩ","cmc":"0,0066 % + 18 Ω"},{"name":"","range":"100 kΩ to 330 kΩ","cmc":"0,011 % + 24 Ω"},{"name":"","range":"330 kΩ to 1 MΩ","cmc":"0,0066 % + 0,18 kΩ"},{"name":"","range":"1 MΩ to 3,3 MΩ","cmc":"0,013 % + 0,24 kΩ"},{"name":"","range":"3,3 MΩ to 10 MΩ","cmc":"0,0075 % + 1,8 kΩ"},{"name":"","range":"10 MΩ to 33 MΩ","cmc":"0,052 % + 6,4 kΩ"},{"name":"","range":"33 MΩ to 100 MΩ","cmc":"0,064 % + 0,21 MΩ"},{"name":"","range":"100 MΩ to 330 MΩ","cmc":"1,3 % + 1,9 MΩ"},{"name":"","range":"330 MΩ to 1 GΩ","cmc":"2,4 % + 13 MΩ"}],"parameters_zh":[{"name":"","range":"0,1 Ω","cmc":"8,7 mΩ"},{"name":"","range":"1 Ω","cmc":"8,9 mΩ"},{"name":"","range":"10 Ω","cmc":"11 mΩ"},{"name":"","range":"100 Ω","cmc":"20 mΩ"},{"name":"","range":"1 kΩ","cmc":"0,16 Ω"},{"name":"","range":"10 kΩ","cmc":"1,6 Ω"},{"name":"","range":"100 kΩ","cmc":"15 Ω"},{"name":"","range":"1 MΩ","cmc":"0,29 kΩ"},{"name":"","range":"10 MΩ","cmc":"8,0 kΩ"},{"name":"","range":"100 MΩ","cmc":"0,98 MΩ"},{"name":"","range":"1 GΩ","cmc":"22 MΩ"},{"name":"","range":"0 Ω 至 100 Ω","cmc":"0,018 % + 88 mΩ"},{"name":"","range":"100 Ω 至 330 Ω","cmc":"0,012 % + 0,11 Ω"},{"name":"","range":"330 Ω 至 1 kΩ","cmc":"0,01 % + 0,19 Ω"},{"name":"","range":"1 kΩ 至 3,3 kΩ","cmc":"0,012 % + 0,29 Ω"},{"name":"","range":"3,3 kΩ 至 10 kΩ","cmc":"0,0082 % + 1,4 Ω"},{"name":"","range":"10 kΩ 至 33 kΩ","cmc":"0,012 % + 2,2 Ω"},{"name":"","range":"33 kΩ 至 100 kΩ","cmc":"0,0066 % + 18 Ω"},{"name":"","range":"100 kΩ 至 330 kΩ","cmc":"0,011 % + 24 Ω"},{"name":"","range":"330 kΩ 至 1 MΩ","cmc":"0,0066 % + 0,18 kΩ"},{"name":"","range":"1 MΩ 至 3,3 MΩ","cmc":"0,013 % + 0,24 kΩ"},{"name":"","range":"3,3 MΩ 至 10 MΩ","cmc":"0,0075 % + 1,8 kΩ"},{"name":"","range":"10 MΩ 至 33 MΩ","cmc":"0,052 % + 6,4 kΩ"},{"name":"","range":"33 MΩ 至 100 MΩ","cmc":"0,064 % + 0,21 MΩ"},{"name":"","range":"100 MΩ 至 330 MΩ","cmc":"1,3 % + 1,9 MΩ"},{"name":"","range":"330 MΩ 至 1 GΩ","cmc":"2,4 % + 13 MΩ"}],"parameters_cs":[{"name":"","range":"0,1 Ω","cmc":"8,7 mΩ"},{"name":"","range":"1 Ω","cmc":"8,9 mΩ"},{"name":"","range":"10 Ω","cmc":"11 mΩ"},{"name":"","range":"100 Ω","cmc":"20 mΩ"},{"name":"","range":"1 kΩ","cmc":"0,16 Ω"},{"name":"","range":"10 kΩ","cmc":"1,6 Ω"},{"name":"","range":"100 kΩ","cmc":"15 Ω"},{"name":"","range":"1 MΩ","cmc":"0,29 kΩ"},{"name":"","range":"10 MΩ","cmc":"8,0 kΩ"},{"name":"","range":"100 MΩ","cmc":"0,98 MΩ"},{"name":"","range":"1 GΩ","cmc":"22 MΩ"},{"name":"","range":"0 Ω až 100 Ω","cmc":"0,018 % + 88 mΩ"},{"name":"","range":"100 Ω až 330 Ω","cmc":"0,012 % + 0,11 Ω"},{"name":"","range":"330 Ω až 1 kΩ","cmc":"0,01 % + 0,19 Ω"},{"name":"","range":"1 kΩ až 3,3 kΩ","cmc":"0,012 % + 0,29 Ω"},{"name":"","range":"3,3 kΩ až 10 kΩ","cmc":"0,0082 % + 1,4 Ω"},{"name":"","range":"10 kΩ až 33 kΩ","cmc":"0,012 % + 2,2 Ω"},{"name":"","range":"33 kΩ až 100 kΩ","cmc":"0,0066 % + 18 Ω"},{"name":"","range":"100 kΩ až 330 kΩ","cmc":"0,011 % + 24 Ω"},{"name":"","range":"330 kΩ až 1 MΩ","cmc":"0,0066 % + 0,18 kΩ"},{"name":"","range":"1 MΩ až 3,3 MΩ","cmc":"0,013 % + 0,24 kΩ"},{"name":"","range":"3,3 MΩ až 10 MΩ","cmc":"0,0075 % + 1,8 kΩ"},{"name":"","range":"10 MΩ až 33 MΩ","cmc":"0,052 % + 6,4 kΩ"},{"name":"","range":"33 MΩ až 100 MΩ","cmc":"0,064 % + 0,21 MΩ"},{"name":"","range":"100 MΩ až 330 MΩ","cmc":"1,3 % + 1,9 MΩ"},{"name":"","range":"330 MΩ až 1 GΩ","cmc":"2,4 % + 13 MΩ"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a standard calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a standard calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,1 Ω CMC 8,7 mΩ\n1 Ω CMC 8,9 mΩ\n10 Ω CMC 11 mΩ\n100 Ω CMC 20 mΩ\n1 kΩ CMC 0,16 Ω\n10 kΩ CMC 1,6 Ω\n100 kΩ CMC 15 Ω\n1 MΩ CMC 0,29 kΩ\n10 MΩ CMC 8,0 kΩ\n100 MΩ CMC 0,98 MΩ\n1 GΩ CMC 22 MΩ\nod 0 Ω do 100 Ω CMC 0,018 % + 88 mΩ\nod 100 Ω do 330 Ω CMC 0,012 % + 0,11 Ω\nod 330 Ω do 1 kΩ CMC 0,01 % + 0,19 Ω\nod 1 kΩ do 3,3 kΩ CMC 0,012 % + 0,29 Ω\nod 3,3 kΩ do 10 kΩ CMC 0,0082 % + 1,4 Ω\nod 10 kΩ do 33 kΩ CMC 0,012 % + 2,2 Ω\nod 33 kΩ do 100 kΩ CMC 0,0066 % + 18 Ω\nod 100 kΩ do 330 kΩ CMC 0,011 % + 24 Ω\nod 330 kΩ do 1 MΩ CMC 0,0066 % + 0,18 kΩ\nod 1 MΩ do 3,3 MΩ CMC 0,013 % + 0,24 kΩ\nod 3,3 MΩ do 10 MΩ CMC 0,0075 % + 1,8 kΩ\nod 10 MΩ do 33 MΩ CMC 0,052 % + 6,4 kΩ\nod 33 MΩ do 100 MΩ CMC 0,064 % + 0,21 MΩ\nod 100 MΩ do 330 MΩ CMC 1,3 % + 1,9 MΩ\nod 330 MΩ do 1 GΩ CMC 2,4 % + 13 MΩ\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"KP EL 1","norm_bases":["KP EL 1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / mierniki rezystancji Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym 0,1 Ω CMC 8,7 mΩ 1 Ω CMC 8,9 mΩ 10 Ω CMC 11 mΩ 100 Ω CMC 20 mΩ 1 kΩ CMC 0,16 Ω 10 kΩ CMC 1,6 Ω 100 kΩ CMC 15 Ω 1 MΩ CMC 0,29 kΩ 10 MΩ CMC 8,0 kΩ 100 MΩ CMC 0,98 MΩ 1 GΩ CMC 22 MΩ od 0 Ω do 100 Ω CMC 0,018 % + 88 mΩ od 100 Ω do 330 Ω CMC 0,012 % + 0,11 Ω od 330 Ω do 1 kΩ CMC 0,01 % + 0,19 Ω od 1 kΩ do 3,3 kΩ CMC 0,012 % + 0,29 Ω od 3,3 kΩ do 10 kΩ CMC 0,0082 % + 1,4 Ω od 10 kΩ do 33 kΩ CMC 0,012 % + 2,2 Ω od 33 kΩ do 100 kΩ CMC 0,0066 % + 18 Ω od 100 kΩ do 330 kΩ CMC 0,011 % + 24 Ω od 330 kΩ do 1 MΩ CMC 0,0066 % + 0,18 kΩ od 1 MΩ do 3,3 MΩ CMC 0,013 % + 0,24 kΩ od 3,3 MΩ do 10 MΩ CMC 0,0075 % + 1,8 kΩ od 10 MΩ do 33 MΩ CMC 0,052 % + 6,4 kΩ od 33 MΩ do 100 MΩ CMC 0,064 % + 0,21 MΩ od 100 MΩ do 330 MΩ CMC 1,3 % + 1,9 MΩ od 330 MΩ do 1 GΩ CMC 2,4 % + 13 MΩ Stejnosměrný odpor / Měřidla stejnosměrného odporu Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 0,1 Ω CMC 8,7 mΩ 1 Ω CMC 8,9 mΩ 10 Ω CMC 11 mΩ 100 Ω CMC 20 mΩ 1 kΩ CMC 0,16 Ω 10 kΩ CMC 1,6 Ω 100 kΩ CMC 15 Ω 1 MΩ CMC 0,29 kΩ 10 MΩ CMC 8,0 kΩ 100 MΩ CMC 0,98 MΩ 1 GΩ CMC 22 MΩ 0 Ω až 100 Ω CMC 0,018 % + 88 mΩ 100 Ω až 330 Ω CMC 0,012 % + 0,11 Ω 330 Ω až 1 kΩ CMC 0,01 % + 0,19 Ω 1 kΩ až 3,3 kΩ CMC 0,012 % + 0,29 Ω 3,3 kΩ až 10 kΩ CMC 0,0082 % + 1,4 Ω 10 kΩ až 33 kΩ CMC 0,012 % + 2,2 Ω 33 kΩ až 100 kΩ CMC 0,0066 % + 18 Ω 100 kΩ až 330 kΩ CMC 0,011 % + 24 Ω 330 kΩ až 1 MΩ CMC 0,0066 % + 0,18 kΩ 1 MΩ až 3,3 MΩ CMC 0,013 % + 0,24 kΩ 3,3 MΩ až 10 MΩ CMC 0,0075 % + 1,8 kΩ 10 MΩ až 33 MΩ CMC 0,052 % + 6,4 kΩ 33 MΩ až 100 MΩ CMC 0,064 % + 0,21 MΩ 100 MΩ až 330 MΩ CMC 1,3 % + 1,9 MΩ 330 MΩ až 1 GΩ CMC 2,4 % + 13 MΩ KP EL 1 Rezystancja przy pradzie stalym / mierniki rezystancji Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym 0,1 Ω CMC 8,7 mΩ 1 Ω CMC 8,9 mΩ 10 Ω CMC 11 mΩ 100 Ω CMC 20 mΩ 1 kΩ CMC 0,16 Ω 10 kΩ CMC 1,6 Ω 100 kΩ CMC 15 Ω 1 MΩ CMC 0,29 kΩ 10 MΩ CMC 8,0 kΩ 100 MΩ CMC 0,98 MΩ 1 GΩ CMC 22 MΩ od 0 Ω do 100 Ω CMC 0,018 % + 88 mΩ od 100 Ω do 330 Ω CMC 0,012 % + 0,11 Ω od 330 Ω do 1 kΩ CMC 0,01 % + 0,19 Ω od 1 kΩ do 3,3 kΩ CMC 0,012 % + 0,29 Ω od 3,3 kΩ do 10 kΩ CMC 0,0082 % + 1,4 Ω od 10 kΩ do 33 kΩ CMC 0,012 % + 2,2 Ω od 33 kΩ do 100 kΩ CMC 0,0066 % + 18 Ω od 100 kΩ do 330 kΩ CMC 0,011 % + 24 Ω od 330 kΩ do 1 MΩ CMC 0,0066 % + 0,18 kΩ od 1 MΩ do 3,3 MΩ CMC 0,013 % + 0,24 kΩ od 3,3 MΩ do 10 MΩ CMC 0,0075 % + 1,8 kΩ od 10 MΩ do 33 MΩ CMC 0,052 % + 6,4 kΩ od 33 MΩ do 100 MΩ CMC 0,064 % + 0,21 MΩ od 100 MΩ do 330 MΩ CMC 1,3 % + 1,9 MΩ od 330 MΩ do 1 GΩ CMC 2,4 % + 13 MΩ Stejnosmerny odpor / Meridla stejnosmerneho odporu Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 0,1 Ω CMC 8,7 mΩ 1 Ω CMC 8,9 mΩ 10 Ω CMC 11 mΩ 100 Ω CMC 20 mΩ 1 kΩ CMC 0,16 Ω 10 kΩ CMC 1,6 Ω 100 kΩ CMC 15 Ω 1 MΩ CMC 0,29 kΩ 10 MΩ CMC 8,0 kΩ 100 MΩ CMC 0,98 MΩ 1 GΩ CMC 22 MΩ 0 Ω az 100 Ω CMC 0,018 % + 88 mΩ 100 Ω az 330 Ω CMC 0,012 % + 0,11 Ω 330 Ω az 1 kΩ CMC 0,01 % + 0,19 Ω 1 kΩ az 3,3 kΩ CMC 0,012 % + 0,29 Ω 3,3 kΩ az 10 kΩ CMC 0,0082 % + 1,4 Ω 10 kΩ az 33 kΩ CMC 0,012 % + 2,2 Ω 33 kΩ az 100 kΩ CMC 0,0066 % + 18 Ω 100 kΩ az 330 kΩ CMC 0,011 % + 24 Ω 330 kΩ az 1 MΩ CMC 0,0066 % + 0,18 kΩ 1 MΩ az 3,3 MΩ CMC 0,013 % + 0,24 kΩ 3,3 MΩ az 10 MΩ CMC 0,0075 % + 1,8 kΩ 10 MΩ az 33 MΩ CMC 0,052 % + 6,4 kΩ 33 MΩ az 100 MΩ CMC 0,064 % + 0,21 MΩ 100 MΩ az 330 MΩ CMC 1,3 % + 1,9 MΩ 330 MΩ az 1 GΩ CMC 2,4 % + 13 MΩ KP EL 1","search_en":"DC resistance / DC resistance meters Calibration – electrical quantities Direct generation with a standard calibrator 0,1 Ω CMC 8,7 mΩ 1 Ω CMC 8,9 mΩ 10 Ω CMC 11 mΩ 100 Ω CMC 20 mΩ 1 kΩ CMC 0,16 Ω 10 kΩ CMC 1,6 Ω 100 kΩ CMC 15 Ω 1 MΩ CMC 0,29 kΩ 10 MΩ CMC 8,0 kΩ 100 MΩ CMC 0,98 MΩ 1 GΩ CMC 22 MΩ 0 Ω to 100 Ω CMC 0,018 % + 88 mΩ 100 Ω to 330 Ω CMC 0,012 % + 0,11 Ω 330 Ω to 1 kΩ CMC 0,01 % + 0,19 Ω 1 kΩ to 3,3 kΩ CMC 0,012 % + 0,29 Ω 3,3 kΩ to 10 kΩ CMC 0,0082 % + 1,4 Ω 10 kΩ to 33 kΩ CMC 0,012 % + 2,2 Ω 33 kΩ to 100 kΩ CMC 0,0066 % + 18 Ω 100 kΩ to 330 kΩ CMC 0,011 % + 24 Ω 330 kΩ to 1 MΩ CMC 0,0066 % + 0,18 kΩ 1 MΩ to 3,3 MΩ CMC 0,013 % + 0,24 kΩ 3,3 MΩ to 10 MΩ CMC 0,0075 % + 1,8 kΩ 10 MΩ to 33 MΩ CMC 0,052 % + 6,4 kΩ 33 MΩ to 100 MΩ CMC 0,064 % + 0,21 MΩ 100 MΩ to 330 MΩ CMC 1,3 % + 1,9 MΩ 330 MΩ to 1 GΩ CMC 2,4 % + 13 MΩ KP EL 1","search_zh":"直流电阻 / 直流电阻测量仪器 校准 – 电学量 用标准校准器直接产生 0,1 Ω CMC 8,7 mΩ 1 Ω CMC 8,9 mΩ 10 Ω CMC 11 mΩ 100 Ω CMC 20 mΩ 1 kΩ CMC 0,16 Ω 10 kΩ CMC 1,6 Ω 100 kΩ CMC 15 Ω 1 MΩ CMC 0,29 kΩ 10 MΩ CMC 8,0 kΩ 100 MΩ CMC 0,98 MΩ 1 GΩ CMC 22 MΩ 0 Ω 至 100 Ω CMC 0,018 % + 88 mΩ 100 Ω 至 330 Ω CMC 0,012 % + 0,11 Ω 330 Ω 至 1 kΩ CMC 0,01 % + 0,19 Ω 1 kΩ 至 3,3 kΩ CMC 0,012 % + 0,29 Ω 3,3 kΩ 至 10 kΩ CMC 0,0082 % + 1,4 Ω 10 kΩ 至 33 kΩ CMC 0,012 % + 2,2 Ω 33 kΩ 至 100 kΩ CMC 0,0066 % + 18 Ω 100 kΩ 至 330 kΩ CMC 0,011 % + 24 Ω 330 kΩ 至 1 MΩ CMC 0,0066 % + 0,18 kΩ 1 MΩ 至 3,3 MΩ CMC 0,013 % + 0,24 kΩ 3,3 MΩ 至 10 MΩ CMC 0,0075 % + 1,8 kΩ 10 MΩ 至 33 MΩ CMC 0,052 % + 6,4 kΩ 33 MΩ 至 100 MΩ CMC 0,064 % + 0,21 MΩ 100 MΩ 至 330 MΩ CMC 1,3 % + 1,9 MΩ 330 MΩ 至 1 GΩ CMC 2,4 % + 13 MΩ KP EL 1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e2a8c77ecbfd07bdbde20f59","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"10","test_object":"Pojemność / mierniki pojemności elektrycznej","test_object_en":"Capacitance / Electrical Capacitance Meters","test_object_zh":"电容 / 电容测量仪器","test_object_cs":"Kapacita / Měřidla elektrické kapacity","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"1 nF","cmc":"0,48 %"},{"name":"1 kHz","range":"2 nF","cmc":"0,73 %"},{"name":"1 kHz","range":"5 nF","cmc":"0,70 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,54 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,41 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,65 %"},{"name":"1 kHz","range":"10 µF","cmc":"0,98 %"}],"parameters_en":[{"name":"1 kHz","range":"1 nF","cmc":"0,48 %"},{"name":"1 kHz","range":"2 nF","cmc":"0,73 %"},{"name":"1 kHz","range":"5 nF","cmc":"0,70 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,54 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,41 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,65 %"},{"name":"1 kHz","range":"10 µF","cmc":"0,98 %"}],"parameters_zh":[{"name":"1 kHz","range":"1 nF","cmc":"0,48 %"},{"name":"1 kHz","range":"2 nF","cmc":"0,73 %"},{"name":"1 kHz","range":"5 nF","cmc":"0,70 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,54 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,41 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,65 %"},{"name":"1 kHz","range":"10 µF","cmc":"0,98 %"}],"parameters_cs":[{"name":"1 kHz","range":"1 nF","cmc":"0,48 %"},{"name":"1 kHz","range":"2 nF","cmc":"0,73 %"},{"name":"1 kHz","range":"5 nF","cmc":"0,70 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,54 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,41 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,65 %"},{"name":"1 kHz","range":"10 µF","cmc":"0,98 %"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation with a standard calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation with a standard calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz 1 nF CMC 0,48 %\n1 kHz 2 nF CMC 0,73 %\n1 kHz 5 nF CMC 0,70 %\n1 kHz 10 nF CMC 0,54 %\n1 kHz 100 nF CMC 0,41 %\n1 kHz 1 µF CMC 0,65 %\n1 kHz 10 µF CMC 0,98 %\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"KP EL1","norm_bases":["KP EL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność / mierniki pojemności elektrycznej Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym 1 kHz 1 nF CMC 0,48 % 1 kHz 2 nF CMC 0,73 % 1 kHz 5 nF CMC 0,70 % 1 kHz 10 nF CMC 0,54 % 1 kHz 100 nF CMC 0,41 % 1 kHz 1 µF CMC 0,65 % 1 kHz 10 µF CMC 0,98 % Kapacita / Měřidla elektrické kapacity Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem 1 kHz 1 nF CMC 0,48 % 1 kHz 2 nF CMC 0,73 % 1 kHz 5 nF CMC 0,70 % 1 kHz 10 nF CMC 0,54 % 1 kHz 100 nF CMC 0,41 % 1 kHz 1 µF CMC 0,65 % 1 kHz 10 µF CMC 0,98 % KP EL1 Pojemnosc / mierniki pojemnosci elektrycznej Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym 1 kHz 1 nF CMC 0,48 % 1 kHz 2 nF CMC 0,73 % 1 kHz 5 nF CMC 0,70 % 1 kHz 10 nF CMC 0,54 % 1 kHz 100 nF CMC 0,41 % 1 kHz 1 µF CMC 0,65 % 1 kHz 10 µF CMC 0,98 % Kapacita / Meridla elektricke kapacity Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem 1 kHz 1 nF CMC 0,48 % 1 kHz 2 nF CMC 0,73 % 1 kHz 5 nF CMC 0,70 % 1 kHz 10 nF CMC 0,54 % 1 kHz 100 nF CMC 0,41 % 1 kHz 1 µF CMC 0,65 % 1 kHz 10 µF CMC 0,98 % KP EL1","search_en":"Capacitance / Electrical Capacitance Meters Calibration – electrical quantities Direct generation with a standard calibrator 1 kHz 1 nF CMC 0,48 % 1 kHz 2 nF CMC 0,73 % 1 kHz 5 nF CMC 0,70 % 1 kHz 10 nF CMC 0,54 % 1 kHz 100 nF CMC 0,41 % 1 kHz 1 µF CMC 0,65 % 1 kHz 10 µF CMC 0,98 % KP EL1","search_zh":"电容 / 电容测量仪器 校准 – 电学量 用标准校准器直接产生 1 kHz 1 nF CMC 0,48 % 1 kHz 2 nF CMC 0,73 % 1 kHz 5 nF CMC 0,70 % 1 kHz 10 nF CMC 0,54 % 1 kHz 100 nF CMC 0,41 % 1 kHz 1 µF CMC 0,65 % 1 kHz 10 µF CMC 0,98 % KP EL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6bef5be5fa1ca42f147f508","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"10","test_object":"Pojemność / mierniki pojemności elektrycznej","test_object_en":"Capacitance / Electrical Capacitance Meters","test_object_zh":"电容 / 电容测量仪器","test_object_cs":"Kapacita / Měřidla elektrické kapacity","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 µF do 100 µF","cmc":"1,2 %"}],"parameters_en":[{"name":"","range":"10 µF to 100 µF","cmc":"1,2 %"}],"parameters_zh":[{"name":"","range":"10 µF 至 100 µF","cmc":"1,2 %"}],"parameters_cs":[{"name":"","range":"10 µF až 100 µF","cmc":"1,2 %"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a standard multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a standard multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 10 µF do 100 µF CMC 1,2 %\nPorównanie z multimetrem wzorcowym","reference":"KP EL1","norm_bases":["KP EL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność / mierniki pojemności elektrycznej Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym od 10 µF do 100 µF CMC 1,2 % Kapacita / Měřidla elektrické kapacity Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 10 µF až 100 µF CMC 1,2 % KP EL1 Pojemnosc / mierniki pojemnosci elektrycznej Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym od 10 µF do 100 µF CMC 1,2 % Kapacita / Meridla elektricke kapacity Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 10 µF az 100 µF CMC 1,2 % KP EL1","search_en":"Capacitance / Electrical Capacitance Meters Calibration – electrical quantities Comparison with a standard multimeter 10 µF to 100 µF CMC 1,2 % KP EL1","search_zh":"电容 / 电容测量仪器 校准 – 电学量 与标准万用表比较 10 µF 至 100 µF CMC 1,2 % KP EL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5dc7071dc9261118a6787ee0","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Przedział czasu / przyrządy do pomiaru czasu, stopery, czasomierze","test_object_en":"Time interval / time meters, stopwatches, timers","test_object_zh":"时间间隔 / 计时器具、秒表、定时器","test_object_cs":"Časový interval / měřidla času, stopky, časovače","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time quantities and frequency","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 1 s do 86400 s","cmc":"0,5 s"}],"parameters_en":[{"name":"","range":"1 s to 86400 s","cmc":"0,5 s"}],"parameters_zh":[{"name":"","range":"1 s 至 86400 s","cmc":"0,5 s"}],"parameters_cs":[{"name":"","range":"1 s až 86400 s","cmc":"0,5 s"}],"technique":"Porównanie z wzorcowymi stoperami cyfrowymi","technique_en":"Comparison with a reference digital stopwatch","technique_zh":"与标准数字秒表比较","technique_cs":"Porovnání s etalonovými číslicovými stopkami","techniques":["Porównanie z wzorcowymi stoperami cyfrowymi"],"techniques_en":["Comparison with a reference digital stopwatch"],"techniques_zh":["与标准数字秒表比较"],"techniques_cs":["Porovnání s etalonovými číslicovými stopkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 1 s do 86400 s CMC 0,5 s\nPorównanie z wzorcowymi stoperami cyfrowymi","reference":"KP Č1","norm_bases":["KP Č1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time quantities and frequency","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / przyrządy do pomiaru czasu, stopery, czasomierze Wzorcowanie – wielkości czasu i częstotliwości Porównanie z wzorcowymi stoperami cyfrowymi od 1 s do 86400 s CMC 0,5 s Časový interval / měřidla času, stopky, časovače Kalibrace – veličiny času a frekvence Porovnání s etalonovými číslicovými stopkami 1 s až 86400 s CMC 0,5 s KP Č1 Przedzial czasu / przyrzady do pomiaru czasu, stopery, czasomierze Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie z wzorcowymi stoperami cyfrowymi od 1 s do 86400 s CMC 0,5 s Casovy interval / meridla casu, stopky, casovace Kalibrace – veliciny casu a frekvence Porovnani s etalonovymi cislicovymi stopkami 1 s az 86400 s CMC 0,5 s KP C1","search_en":"Time interval / time meters, stopwatches, timers Calibration – time quantities and frequency Comparison with a reference digital stopwatch 1 s to 86400 s CMC 0,5 s KP Č1","search_zh":"时间间隔 / 计时器具、秒表、定时器 校准 – 时间和频率量 与标准数字秒表比较 1 s 至 86400 s CMC 0,5 s KP Č1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c503bd9ded89dae196e9c789","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"2","test_object":"Częstotliwość / częstościomierze m.cz. i w.cz.","test_object_en":"Frequency / low frequency and high frequency counters","test_object_zh":"频率 / 低频和高频计数器","test_object_cs":"Frekvence / NF a VF čítače","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time quantities and frequency","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 1 Hz do 100 kHz","cmc":"1,7.10⁻⁶"},{"name":"","range":"od 100 kHz do 1000 kHz","cmc":"2,3.10⁻⁶"},{"name":"","range":"10 MHz","cmc":"1,7.10⁻⁵"}],"parameters_en":[{"name":"","range":"1 Hz to 100 kHz","cmc":"1,7.10⁻⁶"},{"name":"","range":"100 kHz to 1000 kHz","cmc":"2,3.10⁻⁶"},{"name":"","range":"10 MHz","cmc":"1,7.10⁻⁵"}],"parameters_zh":[{"name":"","range":"1 Hz 至 100 kHz","cmc":"1,7.10⁻⁶"},{"name":"","range":"100 kHz 至 1000 kHz","cmc":"2,3.10⁻⁶"},{"name":"","range":"10 MHz","cmc":"1,7.10⁻⁵"}],"parameters_cs":[{"name":"","range":"1 Hz až 100 kHz","cmc":"1,7.10⁻⁶"},{"name":"","range":"100 kHz až 1000 kHz","cmc":"2,3.10⁻⁶"},{"name":"","range":"10 MHz","cmc":"1,7.10⁻⁵"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym","technique_en":"Direct generation by reference calibrator","technique_zh":"用标准校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym"],"techniques_en":["Direct generation by reference calibrator"],"techniques_zh":["用标准校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nod 1 Hz do 100 kHz CMC 1,7.10⁻⁶\nod 100 kHz do 1000 kHz CMC 2,3.10⁻⁶\n10 MHz CMC 1,7.10⁻⁵\nBezpośrednie generowanie kalibratorem wzorcowym","reference":"KP EL1","norm_bases":["KP EL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time quantities and frequency","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / częstościomierze m.cz. i w.cz. Wzorcowanie – wielkości czasu i częstotliwości Bezpośrednie generowanie kalibratorem wzorcowym od 1 Hz do 100 kHz CMC 1,7.10⁻⁶ od 100 kHz do 1000 kHz CMC 2,3.10⁻⁶ 10 MHz CMC 1,7.10⁻⁵ Frekvence / NF a VF čítače Kalibrace – veličiny času a frekvence Přímé generování etalonovým kalibrátorem 1 Hz až 100 kHz CMC 1,7.10⁻⁶ 100 kHz až 1000 kHz CMC 2,3.10⁻⁶ 10 MHz CMC 1,7.10⁻⁵ KP EL1 Czestotliwosc / czestosciomierze m.cz. i w.cz. Wzorcowanie – wielkosci czasu i czestotliwosci Bezposrednie generowanie kalibratorem wzorcowym od 1 Hz do 100 kHz CMC 1,7.10⁻⁶ od 100 kHz do 1000 kHz CMC 2,3.10⁻⁶ 10 MHz CMC 1,7.10⁻⁵ Frekvence / NF a VF citace Kalibrace – veliciny casu a frekvence Prime generovani etalonovym kalibratorem 1 Hz az 100 kHz CMC 1,7.10⁻⁶ 100 kHz az 1000 kHz CMC 2,3.10⁻⁶ 10 MHz CMC 1,7.10⁻⁵ KP EL1","search_en":"Frequency / low frequency and high frequency counters Calibration – time quantities and frequency Direct generation by reference calibrator 1 Hz to 100 kHz CMC 1,7.10⁻⁶ 100 kHz to 1000 kHz CMC 2,3.10⁻⁶ 10 MHz CMC 1,7.10⁻⁵ KP EL1","search_zh":"频率 / 低频和高频计数器 校准 – 时间和频率量 用标准校准器直接产生 1 Hz 至 100 kHz CMC 1,7.10⁻⁶ 100 kHz 至 1000 kHz CMC 2,3.10⁻⁶ 10 MHz CMC 1,7.10⁻⁵ KP EL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7452beda4272531da3b371f4","lab_id":"6ade8b31ff0682476170810e","country":"CZ","accr_number":"2301","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru wilgotności względnej z wyjątkiem psychrometrów","test_object_en":"Relative humidity meters except psychrometers","test_object_zh":"相对湿度测量仪（干湿表除外）","test_object_cs":"Měřidla relativní vlhkosti vyjma psychrometrů","methodology":"Wzorcowanie – wilgotność","methodology_en":"Calibration – humidity","methodology_zh":"校准 – 湿度","methodology_cs":"Kalibrace – vlhkost","parameters":[{"name":"(20 do 40) °C","range":"od 10 % RH do 95 % RH","cmc":"2,3 % RH"}],"parameters_en":[{"name":"(20 to 40) °C","range":"10 % RH to 95 % RH","cmc":"2,3 % RH"}],"parameters_zh":[{"name":"(20 至 40) °C","range":"10 % RH 至 95 % RH","cmc":"2,3 % RH"}],"parameters_cs":[{"name":"(20 až 40) °C","range":"10 % RH až 95 % RH","cmc":"2,3 % RH"}],"technique":"Pomiar porównawczy z higrometrem wzorcowym w generatorze wilgotności","technique_en":"Comparative measurement by a reference hygrometer in a humidity generator","technique_zh":"在湿度发生器中与标准湿度计比较测量","technique_cs":"Porovnávací měření s etalonovým vlhkoměrem v generátoru vlhkosti","techniques":["Pomiar porównawczy z higrometrem wzorcowym w generatorze wilgotności"],"techniques_en":["Comparative measurement by a reference hygrometer in a humidity generator"],"techniques_zh":["在湿度发生器中与标准湿度计比较测量"],"techniques_cs":["Porovnávací měření s etalonovým vlhkoměrem v generátoru vlhkosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność\n(20 do 40) °C od 10 % RH do 95 % RH CMC 2,3 % RH\nPomiar porównawczy z higrometrem wzorcowym w generatorze wilgotności","reference":"KP VL1","norm_bases":["KP VL1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność","regulatory_area_en":"CMC for the field of measured quantity: Humidity","regulatory_area_zh":"被测量领域的CMC：湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru wilgotności względnej z wyjątkiem psychrometrów Wzorcowanie – wilgotność Pomiar porównawczy z higrometrem wzorcowym w generatorze wilgotności (20 do 40) °C od 10 % RH do 95 % RH CMC 2,3 % RH Měřidla relativní vlhkosti vyjma psychrometrů Kalibrace – vlhkost Porovnávací měření s etalonovým vlhkoměrem v generátoru vlhkosti (20 až 40) °C 10 % RH až 95 % RH CMC 2,3 % RH KP VL1 Przyrzady do pomiaru wilgotnosci wzglednej z wyjatkiem psychrometrow Wzorcowanie – wilgotnosc Pomiar porownawczy z higrometrem wzorcowym w generatorze wilgotnosci (20 do 40) °C od 10 % RH do 95 % RH CMC 2,3 % RH Meridla relativni vlhkosti vyjma psychrometru Kalibrace – vlhkost Porovnavaci mereni s etalonovym vlhkomerem v generatoru vlhkosti (20 az 40) °C 10 % RH az 95 % RH CMC 2,3 % RH KP VL1","search_en":"Relative humidity meters except psychrometers Calibration – humidity Comparative measurement by a reference hygrometer in a humidity generator (20 to 40) °C 10 % RH to 95 % RH CMC 2,3 % RH KP VL1","search_zh":"相对湿度测量仪（干湿表除外） 校准 – 湿度 在湿度发生器中与标准湿度计比较测量 (20 至 40) °C 10 % RH 至 95 % RH CMC 2,3 % RH KP VL1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}