🇨🇿 František Knížek PL
Metrology & calibration
František Knížek is a calibration laboratory accredited by ČIA under number 2290 (Lázně Bohdaneč, Czech Republic). Its accreditation scope covers 44 calibration items in the following areas: Metrology & calibration. Calibrated items include: Parallel gauge blocks, Rules, Torque wrenches, screwdrivers, Moment of force meters, Direct indicating thermometers, temperature controllers. Most frequently used calibration principles: Measurement by a torque sensor, Comparison with a standard thermometer in a liquid bath, Measurement on a coordinate measuring machine.
At a glance
- Accreditation number: ČIA 2290
- Calibration items in scope: 44
- Types of calibrated items: 29
- Calibration principles used: 23
- City: Lázně Bohdaneč, Czech Republic
- Valid until: 02-10-2028
- Accreditation number
- 2290
- Accreditation body
- ČIA
- Address
- A. Dvořáka 719, 533 41 Lázně Bohdaneč
- City
- Lázně Bohdaneč, Czech Republic
- Division
- František Knížek – KALEX, ośrodek wzorcujący
- Valid until
- 02-10-2028
What this laboratory calibrates (29)
- Parallel gauge blocks — 4 calibration items
- Rules — 4 calibration items
- Torque wrenches, screwdrivers, Moment of force meters — 4 calibration items
- Direct indicating thermometers, temperature controllers — 2 calibration items
- Measuring chain without a sensor — 2 calibration items
- Resistance sensors — 2 calibration items
- Rigid angle gauges — 2 calibration items
- Thermocouple sensors — 2 calibration items
- Weights and other objects — 2 calibration items
- Angle gauges — 1 calibration item
- Atypical length gauges — 1 calibration item
- Contact thermometers — 1 calibration item
- Deformation manometers, Digital manometers, Pressure measuring chains, Pressure transducers with electrical output — 1 calibration item
- Deviation meters — 1 calibration item
- Force meters, force measuring devices — 1 calibration item
- and 14 more
Calibration principles (23)
- Measurement by a torque sensor — 5 calibration items
- Comparison with a standard thermometer in a liquid bath — 4 calibration items
- Measurement on a coordinate measuring machine — 4 calibration items
- Comparison with a standard thermometer in a vertical furnace — 3 calibration items
- Comparison with parallel gauge blocks in horizontal position on a length gauge — 3 calibration items
- Measurement using parallel gauge blocks — 3 calibration items
- Comparison with a standard weight — 2 calibration items
- Comparison with a steel gauge — 2 calibration items
- Direct measurement on a calibrator — 2 calibration items
- Measurement on a length gauge — 2 calibration items
- Measurement on a small angle generator — 2 calibration items
- Comparison with a reference hygrometer — 1 calibration item
- Comparison with a standard (black body) — 1 calibration item
- Comparison with a standard manometer — 1 calibration item
- Comparison with a standard thermometer — 1 calibration item
- and 8 more
Laboratory sections (2)
- Workplace Lázně Bohdaneč — 36 calibration items
- Workplace Vlčí Habřina — 8 calibration items
Laboratory locations
- František Knížek (main site) — A. Dvořáka 719, 533 41 Lázně Bohdaneč
- Pracownia Lázně Bohdaneč — A. Dvořáka 719, 533 41 Lázně Bohdaneč
- Pracownia Vlčí Habřina — Vlčí Habřina 122, 533 41 Lázně Bohdaneč
Certificate information
- Certificate date
- 02.10.2023
Accreditation scope — calibration items (44)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Workplace Lázně Bohdaneč | |||||
| 1 | Parallel gauge blocks | Calibration – length 0,5 mm to 100 mm · CMC (2L + 0,2) µm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks in vertical position on a comparator | KPA-1.01 | |
| 2 | Parallel gauge blocks | Calibration – length 125 mm to 500 mm · CMC (2,2L + 0,3) µm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks in horizontal position on a length gauge | KPA-1.01 | |
| 3 | Slide gauges, depth gauges, height gauges | Calibration – length 0 mm to 3000 mm · CMC (8,7L + 11) µm CMC for the field of measured quantity: Length |
Measurement using parallel gauge blocks | KPA-1.02 | |
| 4 | Micrometers for external measurement | Calibration – length Micrometer calliper gauges — 0 mm to 500 mm · CMC (3L + 1) µm Pasameters — 0 mm to 500 mm · CMC (3L + 1) µm Micropasameters — 0 mm to 500 mm · CMC (3L + 1) µm CMC for the field of measured quantity: Length |
Measurement using parallel gauge blocks | KPA-1.03 | |
| 5 | Micrometers for internal measurement | Calibration – length Inside micrometer gauges — 14 mm to 500 mm · CMC (3L + 1) µm Micrometer depth gauges — 14 mm to 500 mm · CMC (2L + 1,1) µm Inside micrometers — 14 mm to 500 mm · CMC (2L + 1,1) µm Micrometric heads — 0 mm to 500 mm · CMC (3L + 1) µm CMC for the field of measured quantity: Length |
Measurement using parallel gauge blocks | KPA-1.04 | |
| 6 | Deviation meters | Calibration – length Dial gauges — 0 mm to 100 mm · CMC 0,88 µm Pupitasts — 0 mm to 100 mm · CMC 1,2 µm Somcators — 0 mm to 100 mm · CMC 1,2 µm Internal gauges — 0 mm to 100 mm · CMC 1,2 µm CMC for the field of measured quantity: Length |
Measurement on a dial indicator calibration instrument | KPA-1.05 | |
| 7 | Limit gauges for external measurement | Calibration – length Snap gauges — 1 mm to 500 mm · CMC (3L + 1) µm Plain rings — 1 mm to 500 mm · CMC (3,6L + 1,2) µm Threaded rings — 1 mm to 500 mm · CMC (7,4L + 2,1) µm CMC for the field of measured quantity: Length |
Measurement on a length gauge | KPA-1.06 | |
| 8 | Limit gauges for internal measurement | Calibration – length cylinder, flat — 0 mm to 500 mm · CMC (5,3L + 0,75) µm Thread gauges — 0 mm to 500 mm · CMC (2,8L + 2,8) µm Feeler gauges — 0 mm to 500 mm · CMC 3,6 µm Measuring wires — 0 mm to 500 mm · CMC 0,54 µm Gauges for radius — 0 mm to 500 mm · CMC 4,0 µm Gauges for threads — 0 mm to 500 mm · CMC 4,0 µm Gauges for paint thickness — 0 mm to 500 mm · CMC 1,4 µm CMC for the field of measured quantity: Length |
Measurement on a length gauge | KPA-1.07 | |
| 9 | Rules | Calibration – length Steel rules — 0 mm to 10000 mm · CMC (4,6L + 4,7) µm Measuring magnifier — 0 mm to 100 mm · CMC (4,6L + 4,7) µm CMC for the field of measured quantity: Length |
Measurement on a coordinate measuring machine | KPA-1.08 | |
| 10 | Rules | Calibration – length Steel tape measures — 0 mm to 10000 mm · CMC (3,8L + 140) µm Tapes — 0 m to 100 m · CMC (0,06L + 0,3) mm CMC for the field of measured quantity: Length |
Comparison with a steel gauge | KPA-1.08 | |
| 11 | Two-coordinate measuring machines, Measuring microscopes, Profile projectors | Calibration – length 0 mm to 1000 mm · CMC 3,2 µm CMC for the field of measured quantity: Length |
Measuring with a glass ruler | KPA-1.09 | |
| 12 | Atypical length gauges | Calibration – length 0 mm to 250 mm · CMC 4,0 µm CMC for the field of measured quantity: Length |
Measurement on a coordinate measuring machine | KPA-1.10 | |
| 13 | Surface plates, blocks, plates (longer side up to 5,000 mm) | Calibration – length flatness, straightness — 0 mm to 10 mm · CMC 3,8 µm CMC for the field of measured quantity: Length |
Measurement by an electronic level | KPA-1.13 | |
| 14 | Length gauges | Calibration – length 0 mm to 1000 mm · CMC (2L + 0,25) µm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | KPA-1.14 | |
| 15 | Rigid angle gauges | Calibration – plane angle check squares – angle between arms — 0° to 180° · CMC 32 µm/m taper gauges — 0° to 90° · CMC 7´´ CMC for the field of measured quantity: Plane angle |
Measurement on a coordinate measuring machine | KPA-1.11 | |
| 16 | Rigid angle gauges | Calibration – plane angle centre squares — 0° to 90° · CMC 32 µm/m gauges for threads — 0° to 90° · CMC 7´´ CMC for the field of measured quantity: Plane angle |
Measurement on a small angle generator | KPA-1.11 | |
| 17 | Angle gauges | Calibration – plane angle 0° to 360° · CMC 1,8´ CMC for the field of measured quantity: Plane angle |
Measurement using angle gauges | KPA-1.12 | |
| 18 | Machinery levels – sensitivity measurement | Calibration – plane angle Nominal sensitivity up to 0.02 mm/m — -1° to 1° · CMC 5 µm/m CMC for the field of measured quantity: Plane angle |
Measurement on a small angle generator | KPA-1.11 | |
| 19 | Scales with non-automatic function, mechanical, digital | Calibration – mass class E2 — 0 kg to 2 kg · CMC 1,6·10⁻⁶ class F1 — 2 kg to 3 kg · CMC 5·10⁻⁶ class F2 — 3 kg to 45 kg · CMC 1,6·10⁻⁵ class M1 — 45 kg to 6000 kg · CMC 5·10⁻⁵ class M1 with substitute load — 6000 kg to 30000 kg · CMC 1,6·10⁻⁴ CMC for the field of measured quantity: Mass |
Loading using a reference weight | KPA-2.01 | |
| 20 | Weights and other objects | Calibration – mass 1 g to 500 g · CMC 8,2 mg 0,5 kg to 1 kg · CMC 8,6 mg 1 kg to 2 kg · CMC 10 mg 2 kg to 5 kg · CMC 16 mg 5 kg to 20 kg · CMC 59 mg CMC for the field of measured quantity: Mass |
Comparison with a standard weight | KPA-2.01 | |
| 21 | Torque drivers | Calibration – force, torque 0,25 Nm to 50 Nm · CMC 0,01 CMC for the field of measured quantity: Force, torque |
Measurement by a torque sensor | KPA-5.01 | |
| 22 | Torque wrenches, screwdrivers, Moment of force meters | Calibration – force, torque 0,25 Nm to 0,5 Nm · CMC 0,01 0,5 Nm to 200 Nm · CMC 0,005 CMC for the field of measured quantity: Force, torque |
Measurement by a torque sensor | KPA-5.01 | |
| 23 | Torque wrenches, screwdrivers, Moment of force meters | Calibration – force, torque 200 Nm to 500 Nm · CMC 0,005 CMC for the field of measured quantity: Force, torque |
Measurement by a torque sensor | KPA-5.01 | |
| 24 | Force meters, force measuring devices | Calibration – force, torque Tension, Compression — 0 N to 500 N · CMC 0,001 Tension, Compression — 500 N to 10000 N · CMC 0,003 Tension, Compression — 10000 N to 100000 N · CMC 0,005 CMC for the field of measured quantity: Force, torque |
Measurement by a reference force meter | KPA-5.02 | |
| 25 | Deformation manometers, Digital manometers, Pressure measuring chains, Pressure transducers with electrical output | Calibration – pressure Underpressure / overpressure, Gases — -95 kPa to 350 kPa · CMC 0,26 kPa Underpressure / overpressure, Gases — 350 kPa to 1000 kPa · CMC 0,58 kPa Underpressure / overpressure, Gases — 1 MPa to 3,5 MPa · CMC 2,1 kPa Underpressure / overpressure, Gases — 3,5 MPa to 6 MPa · CMC 6,9 kPa Underpressure / overpressure, Liquids — 0 MPa to 20 MPa · CMC 35 kPa Underpressure / overpressure, Liquids — 20 MPa to 50 MPa · CMC 87 kPa CMC for the field of measured quantity: Pressure |
Comparison with a standard manometer | KPA-4.01, KPA-4.02 | |
| 26 | Direct indicating thermometers, temperature controllers | Calibration – temperature -40 °C to 200 °C · CMC 0,08 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard thermometer in a liquid bath | KPA-3.02 | |
| 27 | Direct indicating thermometers, temperature controllers | Calibration – temperature 200 °C to 400 °C · CMC 0,44 °C 400 °C to 650 °C · CMC 1,5 °C 650 °C to 900 °C · CMC 1,8 °C 900 °C to 1200 °C · CMC 2,4 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard thermometer in a vertical furnace | KPA-3.02 | |
| 28 | Infrared thermometers | Calibration – temperature 50 °C to 500 °C · CMC 3,2 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard (black body) | KPA-3.03 | |
| 29 | Contact thermometers | Calibration – temperature 0 °C to 50 °C · CMC 1,7 °C 50 °C to 100 °C · CMC 1,9 °C 100 °C to 200 °C · CMC 2,3 °C 200 °C to 400 °C · CMC 2,6 °C 400 °C to 600 °C · CMC 3,5 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard thermometer | KPA-3.04 | |
| 30 | Thermocouple sensors | Calibration – temperature K, J, N — -40 °C to 200 °C · CMC 0,4 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard thermometer in a liquid bath | KPA-3.05 | |
| 31 | Thermocouple sensors | Calibration – temperature K, J, N — 200 °C to 400 °C · CMC 0,6 °C K, J, N — 400 °C to 650 °C · CMC 1,6 °C K, J, N — 650 °C to 900 °C · CMC 2,3 °C K, J, N — 900 °C to 1100 °C · CMC 2,6 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard thermometer in a vertical furnace | KPA-3.05 | |
| 32 | Measuring chain without a sensor | Calibration – temperature K, J, N — -100 °C to 1100 °C · CMC 0,3 °C CMC for the field of measured quantity: Temperature |
Direct measurement on a calibrator | KPA-3.05 | |
| 33 | Resistance sensors | Calibration – temperature -40 °C to 200 °C · CMC 0,2 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard thermometer in a liquid bath | KPA-3.06 | |
| 34 | Resistance sensors | Calibration – temperature 200 °C to 400 °C · CMC 0,5 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard thermometer in a vertical furnace | KPA-3.06 | |
| 35 | Measuring chain without a sensor | Calibration – temperature -100 °C to 400 °C · CMC 0,2 °C CMC for the field of measured quantity: Temperature |
Direct measurement on a calibrator | KPA-3.06 | |
| 36 | Instruments for measuring air humidity | Calibration – humidity Temperature range (15 to 60) °C — 10 % RV to 90 % RV · CMC 0,01 + 1,6 % RV CMC for the field of measured quantity: Humidity |
Comparison with a reference hygrometer | KPA-6.01 | |
| Workplace Vlčí Habřina | |||||
| 37 | Parallel gauge blocks | Calibration – length 125 mm to 500 mm · CMC (2,2L + 0,3) µm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks in horizontal position on a length gauge | KPA-1.01 | |
| 38 | Parallel gauge blocks | Calibration – length 500 mm to 1000 mm · CMC (2,2L + 0,3) µm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks in horizontal position on a length gauge | KPA-1.01 | |
| 39 | Rules | Calibration – length Steel rules — 0 mm to 10000 mm · CMC (4,6L + 4,7) µm Measuring magnifier — 0 mm to 100 mm · CMC (4,6L + 4,7) µm CMC for the field of measured quantity: Length |
Measurement on a coordinate measuring machine | KPA-1.08 | |
| 40 | Rules | Calibration – length Steel tape measures — 0 mm to 10000 mm · CMC (3,8L + 140) µm Tapes — 0 m to 100 m · CMC (0,06L + 0,3) mm CMC for the field of measured quantity: Length |
Comparison with a steel gauge | KPA-1.08 | |
| 41 | Weights and other objects | Calibration – mass 1 g to 500 g · CMC 8,2 mg 0,5 kg to 1 kg · CMC 8,6 mg 1 kg to 2 kg · CMC 10 mg 2 kg to 5 kg · CMC 16 mg 5 kg to 20 kg · CMC 59 mg CMC for the field of measured quantity: Mass |
Comparison with a standard weight | KPA-2.01 | |
| 42 | Torque wrenches, screwdrivers, Moment of force meters | Calibration – force, torque 200 Nm to 500 Nm · CMC 0,005 CMC for the field of measured quantity: Force, torque |
Measurement by a torque sensor | KPA-5.01 | |
| 43 | Torque wrenches, screwdrivers, Moment of force meters | Calibration – force, torque 500 Nm to 2000 Nm · CMC 0,005 CMC for the field of measured quantity: Force, torque |
Measurement by a torque sensor | KPA-5.01 | |
| 44 | Glass thermometers | Calibration – temperature -40 °C to 200 °C · CMC 0,07 °C 0 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard thermometer in a liquid bath | KPA-3.01 | |
Reference standards (26)
KPA-1.01
KPA-1.02
KPA-1.03
KPA-1.04
KPA-1.05
KPA-1.06
KPA-1.07
KPA-1.08
KPA-1.09
KPA-1.10
KPA-1.11
KPA-1.12
KPA-1.13
KPA-1.14
KPA-2.01
KPA-3.01
KPA-3.02
KPA-3.03
KPA-3.04
KPA-3.05
KPA-3.06
KPA-4.01
KPA-4.02
KPA-5.01
KPA-5.02
KPA-6.01