{"lab":{"_id":"6ade8b30ff06824761708109","accr_number":"2290","country":"CZ","accr_body":"ČIA","address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","categories":["metrology"],"city":"Lázně Bohdaneč","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[15.6743438,50.0782475]},"map_coord":[50.0782475,15.6743438],"map_geo":"cai-mapa","methods_count":44,"name":"František Knížek","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów pomiarowych w dziedzinach: długość, kąt płaski, masa, siła i moment siły, ciśnienie, temperatura i wilgotność.","search_text":"františek knížek a. dvořáka 719, 533 41 lázně bohdaneč 2290","source_page_url":"https://www.cai.cz/?subjekt=2290-frantisek-knizek","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"02-10-2028","website":"www.kalex.cz","certificate_date":"02.10.2023","certificate_no":"515/2023","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów pomiarowych w dziedzinach: długość, kąt płaski, masa, siła i moment siły, ciśnienie, temperatura i wilgotność.","en":"Calibration of meters in the field of length, plane angle, mass, force and torque, pressure, temperature and humidity.","zh":"长度、平面角、质量、力和扭矩、压力、温度和湿度领域测量仪器的校准。","cs":"Kalibrace měřidel v oborech délka, rovinný úhel, hmotnost, síla a moment síly, tlak, teplota a vlhkost."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"František Knížek – KALEX, ośrodek wzorcujący","lab_division_cs":"František Knížek – KALEX, kalibrační středisko","lab_division_en":"František Knížek - KALEX, Calibration Centre","lab_division_zh":"František Knížek – KALEX 校准中心","lab_locations":[{"code":null,"name":"František Knížek","street":"A. Dvořáka 719","postal_code":"533 41","city":"Lázně Bohdaneč","is_hq":true,"address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","site":"53341|advořáka719"},{"code":null,"name":"Pracownia Lázně Bohdaneč","street":"A. Dvořáka 719","postal_code":"533 41","city":"Lázně Bohdaneč","is_hq":false,"address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","site":"53341|advořáka719"},{"code":null,"name":"Pracownia Vlčí Habřina","street":"Vlčí Habřina 122","postal_code":"533 41","city":"Lázně Bohdaneč","is_hq":false,"address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","site":"53341|vlčíhabřina122"}],"lab_locations_en":[{"code":null,"name":"František Knížek","street":"A. Dvořáka 719","postal_code":"533 41","city":"Lázně Bohdaneč","is_hq":true,"address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","site":"53341|advořáka719"},{"code":null,"name":"Workplace Lázně Bohdaneč","street":"A. Dvořáka 719","postal_code":"533 41","city":"Lázně Bohdaneč","is_hq":false,"address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","site":"53341|advořáka719"},{"code":null,"name":"Workplace Vlčí Habřina","street":"Vlčí Habřina 122","postal_code":"533 41","city":"Lázně Bohdaneč","is_hq":false,"address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","site":"53341|vlčíhabřina122"}],"lab_locations_zh":[{"code":null,"name":"František Knížek","street":"A. Dvořáka 719","postal_code":"533 41","city":"Lázně Bohdaneč","is_hq":true,"address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","site":"53341|advořáka719"},{"code":null,"name":"Lázně Bohdaneč 工作场所","street":"A. Dvořáka 719","postal_code":"533 41","city":"Lázně Bohdaneč","is_hq":false,"address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","site":"53341|advořáka719"},{"code":null,"name":"Vlčí Habřina 工作场所","street":"Vlčí Habřina 122","postal_code":"533 41","city":"Lázně Bohdaneč","is_hq":false,"address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","site":"53341|vlčíhabřina122"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"d7f41a47ab55c24b1cbe6f558b2a13ec5e7bbf6ebca1b6e8176f8df23e8b62fc","source_pdf_url":"https://www.cai.cz/OA/pdf/P515_2023_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P515_2023_EN.pdf"},"methods":[{"_id":"c08df4f62602d60eb0bd8cce","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Płytki wzorcowe","test_object_en":"Parallel gauge blocks","test_object_zh":"量块","test_object_cs":"Koncové měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,5 mm do 100 mm","cmc":"(2L + 0,2) µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 100 mm","cmc":"(2L + 0,2) µm"}],"parameters_zh":[{"name":"","range":"0,5 mm 至 100 mm","cmc":"(2L + 0,2) µm"}],"parameters_cs":[{"name":"","range":"0,5 mm až 100 mm","cmc":"(2L + 0,2) µm"}],"technique":"Porównanie z płytkami wzorcowymi w położeniu pionowym na komparatorze","technique_en":"Comparison with parallel gauge blocks in vertical position on a comparator","technique_zh":"在比较仪上以垂直位置与量块比较","technique_cs":"Porovnání s koncovými měrkami ve svislé poloze na komparačním přístroji","techniques":["Porównanie z płytkami wzorcowymi w położeniu pionowym na komparatorze"],"techniques_en":["Comparison with parallel gauge blocks in vertical position on a comparator"],"techniques_zh":["在比较仪上以垂直位置与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami ve svislé poloze na komparačním přístroji"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,5 mm do 100 mm CMC (2L + 0,2) µm\nPorównanie z płytkami wzorcowymi w położeniu pionowym na komparatorze","reference":"KPA-1.01","norm_bases":["KPA-1.01"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi w położeniu pionowym na komparatorze od 0,5 mm do 100 mm CMC (2L + 0,2) µm Koncové měrky Kalibrace – délka Porovnání s koncovými měrkami ve svislé poloze na komparačním přístroji 0,5 mm až 100 mm CMC (2L + 0,2) µm KPA-1.01 Plytki wzorcowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi w polozeniu pionowym na komparatorze od 0,5 mm do 100 mm CMC (2L + 0,2) µm Koncove merky Kalibrace – delka Porovnani s koncovymi merkami ve svisle poloze na komparacnim pristroji 0,5 mm az 100 mm CMC (2L + 0,2) µm KPA-1.01","search_en":"Parallel gauge blocks Calibration – length Comparison with parallel gauge blocks in vertical position on a comparator 0,5 mm to 100 mm CMC (2L + 0,2) µm KPA-1.01","search_zh":"量块 校准 – 长度 在比较仪上以垂直位置与量块比较 0,5 mm 至 100 mm CMC (2L + 0,2) µm KPA-1.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"609eb3e4969c1997aee52eb4","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Płytki wzorcowe","test_object_en":"Parallel gauge blocks","test_object_zh":"量块","test_object_cs":"Koncové měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 125 mm do 500 mm","cmc":"(2,2L + 0,3) µm"}],"parameters_en":[{"name":"","range":"125 mm to 500 mm","cmc":"(2,2L + 0,3) µm"}],"parameters_zh":[{"name":"","range":"125 mm 至 500 mm","cmc":"(2,2L + 0,3) µm"}],"parameters_cs":[{"name":"","range":"125 mm až 500 mm","cmc":"(2,2L + 0,3) µm"}],"technique":"Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu","technique_en":"Comparison with parallel gauge blocks in horizontal position on a length gauge","technique_zh":"在测长仪上以水平位置与量块比较","technique_cs":"Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru","techniques":["Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu"],"techniques_en":["Comparison with parallel gauge blocks in horizontal position on a length gauge"],"techniques_zh":["在测长仪上以水平位置与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 125 mm do 500 mm CMC (2,2L + 0,3) µm\nPorównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu","reference":"KPA-1.01","norm_bases":["KPA-1.01"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu od 125 mm do 500 mm CMC (2,2L + 0,3) µm Koncové měrky Kalibrace – délka Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru 125 mm až 500 mm CMC (2,2L + 0,3) µm KPA-1.01 Plytki wzorcowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi w polozeniu poziomym na dlugosciomierzu od 125 mm do 500 mm CMC (2,2L + 0,3) µm Koncove merky Kalibrace – delka Porovnani s koncovymi merkami ve vodorovne poloze na delkomeru 125 mm az 500 mm CMC (2,2L + 0,3) µm KPA-1.01","search_en":"Parallel gauge blocks Calibration – length Comparison with parallel gauge blocks in horizontal position on a length gauge 125 mm to 500 mm CMC (2,2L + 0,3) µm KPA-1.01","search_zh":"量块 校准 – 长度 在测长仪上以水平位置与量块比较 125 mm 至 500 mm CMC (2,2L + 0,3) µm KPA-1.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1199e28104e37d141c3ee093","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Płytki wzorcowe","test_object_en":"Parallel gauge blocks","test_object_zh":"量块","test_object_cs":"Koncové měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 125 mm do 500 mm","cmc":"(2,2L + 0,3) µm"}],"parameters_en":[{"name":"","range":"125 mm to 500 mm","cmc":"(2,2L + 0,3) µm"}],"parameters_zh":[{"name":"","range":"125 mm 至 500 mm","cmc":"(2,2L + 0,3) µm"}],"parameters_cs":[{"name":"","range":"125 mm až 500 mm","cmc":"(2,2L + 0,3) µm"}],"technique":"Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu","technique_en":"Comparison with parallel gauge blocks in horizontal position on a length gauge","technique_zh":"在测长仪上以水平位置与量块比较","technique_cs":"Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru","techniques":["Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu"],"techniques_en":["Comparison with parallel gauge blocks in horizontal position on a length gauge"],"techniques_zh":["在测长仪上以水平位置与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 125 mm do 500 mm CMC (2,2L + 0,3) µm\nPorównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu","reference":"KPA-1.01","norm_bases":["KPA-1.01"],"lab_section":"Pracownia Vlčí Habřina","lab_section_en":"Workplace Vlčí Habřina","lab_section_zh":"Vlčí Habřina 工作场所","lab_section_cs":"Pracoviště Vlčí Habřina","lab_address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu od 125 mm do 500 mm CMC (2,2L + 0,3) µm Koncové měrky Kalibrace – délka Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru 125 mm až 500 mm CMC (2,2L + 0,3) µm KPA-1.01 Plytki wzorcowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi w polozeniu poziomym na dlugosciomierzu od 125 mm do 500 mm CMC (2,2L + 0,3) µm Koncove merky Kalibrace – delka Porovnani s koncovymi merkami ve vodorovne poloze na delkomeru 125 mm az 500 mm CMC (2,2L + 0,3) µm KPA-1.01","search_en":"Parallel gauge blocks Calibration – length Comparison with parallel gauge blocks in horizontal position on a length gauge 125 mm to 500 mm CMC (2,2L + 0,3) µm KPA-1.01","search_zh":"量块 校准 – 长度 在测长仪上以水平位置与量块比较 125 mm 至 500 mm CMC (2,2L + 0,3) µm KPA-1.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d3a16a99c76fbc73a10bb60e","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Płytki wzorcowe","test_object_en":"Parallel gauge blocks","test_object_zh":"量块","test_object_cs":"Koncové měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 500 mm do 1000 mm","cmc":"(2,2L + 0,3) µm"}],"parameters_en":[{"name":"","range":"500 mm to 1000 mm","cmc":"(2,2L + 0,3) µm"}],"parameters_zh":[{"name":"","range":"500 mm 至 1000 mm","cmc":"(2,2L + 0,3) µm"}],"parameters_cs":[{"name":"","range":"500 mm až 1000 mm","cmc":"(2,2L + 0,3) µm"}],"technique":"Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu","technique_en":"Comparison with parallel gauge blocks in horizontal position on a length gauge","technique_zh":"在测长仪上以水平位置与量块比较","technique_cs":"Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru","techniques":["Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu"],"techniques_en":["Comparison with parallel gauge blocks in horizontal position on a length gauge"],"techniques_zh":["在测长仪上以水平位置与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 500 mm do 1000 mm CMC (2,2L + 0,3) µm\nPorównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu","reference":"KPA-1.01","norm_bases":["KPA-1.01"],"lab_section":"Pracownia Vlčí Habřina","lab_section_en":"Workplace Vlčí Habřina","lab_section_zh":"Vlčí Habřina 工作场所","lab_section_cs":"Pracoviště Vlčí Habřina","lab_address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe Wzorcowanie – długość Porównanie z płytkami wzorcowymi w położeniu poziomym na długościomierzu od 500 mm do 1000 mm CMC (2,2L + 0,3) µm Koncové měrky Kalibrace – délka Porovnání s koncovými měrkami ve vodorovné poloze na délkoměru 500 mm až 1000 mm CMC (2,2L + 0,3) µm KPA-1.01 Plytki wzorcowe Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi w polozeniu poziomym na dlugosciomierzu od 500 mm do 1000 mm CMC (2,2L + 0,3) µm Koncove merky Kalibrace – delka Porovnani s koncovymi merkami ve vodorovne poloze na delkomeru 500 mm az 1000 mm CMC (2,2L + 0,3) µm KPA-1.01","search_en":"Parallel gauge blocks Calibration – length Comparison with parallel gauge blocks in horizontal position on a length gauge 500 mm to 1000 mm CMC (2,2L + 0,3) µm KPA-1.01","search_zh":"量块 校准 – 长度 在测长仪上以水平位置与量块比较 500 mm 至 1000 mm CMC (2,2L + 0,3) µm KPA-1.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8676cd85bcc78cc2da6aa742","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"2","test_object":"Suwmiarki, głębokościomierze, wysokościomierze","test_object_en":"Slide gauges, depth gauges, height gauges","test_object_zh":"游标卡尺、深度尺、高度尺","test_object_cs":"Posuvná měřidla, hloubkoměry, výškoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 3000 mm","cmc":"(8,7L + 11) µm"}],"parameters_en":[{"name":"","range":"0 mm to 3000 mm","cmc":"(8,7L + 11) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 3000 mm","cmc":"(8,7L + 11) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 3000 mm","cmc":"(8,7L + 11) µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 3000 mm CMC (8,7L + 11) µm\nPomiar za pomocą płytek wzorcowych","reference":"KPA-1.02","norm_bases":["KPA-1.02"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Suwmiarki, głębokościomierze, wysokościomierze Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 0 mm do 3000 mm CMC (8,7L + 11) µm Posuvná měřidla, hloubkoměry, výškoměry Kalibrace – délka Měření pomocí koncových měrek 0 mm až 3000 mm CMC (8,7L + 11) µm KPA-1.02 Suwmiarki, glebokosciomierze, wysokosciomierze Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 0 mm do 3000 mm CMC (8,7L + 11) µm Posuvna meridla, hloubkomery, vyskomery Kalibrace – delka Mereni pomoci koncovych merek 0 mm az 3000 mm CMC (8,7L + 11) µm KPA-1.02","search_en":"Slide gauges, depth gauges, height gauges Calibration – length Measurement using parallel gauge blocks 0 mm to 3000 mm CMC (8,7L + 11) µm KPA-1.02","search_zh":"游标卡尺、深度尺、高度尺 校准 – 长度 用量块测量 0 mm 至 3000 mm CMC (8,7L + 11) µm KPA-1.02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"41a6e3b188b7fb7a7bec2214","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"3","test_object":"Mikrometry do pomiarów zewnętrznych","test_object_en":"Micrometers for external measurement","test_object_zh":"外径千分尺","test_object_cs":"Mikrometry pro vnější měření","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"kabłąkowe","range":"od 0 mm do 500 mm","cmc":"(3L + 1) µm"},{"name":"pasametry","range":"od 0 mm do 500 mm","cmc":"(3L + 1) µm"},{"name":"mikropasametry","range":"od 0 mm do 500 mm","cmc":"(3L + 1) µm"}],"parameters_en":[{"name":"Micrometer calliper gauges","range":"0 mm to 500 mm","cmc":"(3L + 1) µm"},{"name":"Pasameters","range":"0 mm to 500 mm","cmc":"(3L + 1) µm"},{"name":"Micropasameters","range":"0 mm to 500 mm","cmc":"(3L + 1) µm"}],"parameters_zh":[{"name":"外径千分尺","range":"0 mm 至 500 mm","cmc":"(3L + 1) µm"},{"name":"杠杆卡规","range":"0 mm 至 500 mm","cmc":"(3L + 1) µm"},{"name":"杠杆千分尺","range":"0 mm 至 500 mm","cmc":"(3L + 1) µm"}],"parameters_cs":[{"name":"třmenové","range":"0 mm až 500 mm","cmc":"(3L + 1) µm"},{"name":"pasametry","range":"0 mm až 500 mm","cmc":"(3L + 1) µm"},{"name":"mikropasametry","range":"0 mm až 500 mm","cmc":"(3L + 1) µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nkabłąkowe od 0 mm do 500 mm CMC (3L + 1) µm\npasametry od 0 mm do 500 mm CMC (3L + 1) µm\nmikropasametry od 0 mm do 500 mm CMC (3L + 1) µm\nPomiar za pomocą płytek wzorcowych","reference":"KPA-1.03","norm_bases":["KPA-1.03"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mikrometry do pomiarów zewnętrznych Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych kabłąkowe od 0 mm do 500 mm CMC (3L + 1) µm pasametry od 0 mm do 500 mm CMC (3L + 1) µm mikropasametry od 0 mm do 500 mm CMC (3L + 1) µm Mikrometry pro vnější měření Kalibrace – délka Měření pomocí koncových měrek třmenové 0 mm až 500 mm CMC (3L + 1) µm pasametry 0 mm až 500 mm CMC (3L + 1) µm mikropasametry 0 mm až 500 mm CMC (3L + 1) µm KPA-1.03 Mikrometry do pomiarow zewnetrznych Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych kablakowe od 0 mm do 500 mm CMC (3L + 1) µm pasametry od 0 mm do 500 mm CMC (3L + 1) µm mikropasametry od 0 mm do 500 mm CMC (3L + 1) µm Mikrometry pro vnejsi mereni Kalibrace – delka Mereni pomoci koncovych merek trmenove 0 mm az 500 mm CMC (3L + 1) µm pasametry 0 mm az 500 mm CMC (3L + 1) µm mikropasametry 0 mm az 500 mm CMC (3L + 1) µm KPA-1.03","search_en":"Micrometers for external measurement Calibration – length Measurement using parallel gauge blocks Micrometer calliper gauges 0 mm to 500 mm CMC (3L + 1) µm Pasameters 0 mm to 500 mm CMC (3L + 1) µm Micropasameters 0 mm to 500 mm CMC (3L + 1) µm KPA-1.03","search_zh":"外径千分尺 校准 – 长度 用量块测量 外径千分尺 0 mm 至 500 mm CMC (3L + 1) µm 杠杆卡规 0 mm 至 500 mm CMC (3L + 1) µm 杠杆千分尺 0 mm 至 500 mm CMC (3L + 1) µm KPA-1.03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"742ef0763b1033b73b0e1a85","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"4","test_object":"Mikrometry do pomiarów wewnętrznych","test_object_en":"Micrometers for internal measurement","test_object_zh":"内测千分尺","test_object_cs":"Mikrometry pro vnitřní měření","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"średnicówki mikrometryczne prętowe","range":"od 14 mm do 500 mm","cmc":"(3L + 1) µm"},{"name":"głębokościomierze mikrometryczne","range":"od 14 mm do 500 mm","cmc":"(2L + 1,1) µm"},{"name":"mikrometry do otworów","range":"od 14 mm do 500 mm","cmc":"(2L + 1,1) µm"},{"name":"głowica mikrometryczna","range":"od 0 mm do 500 mm","cmc":"(3L + 1) µm"}],"parameters_en":[{"name":"Inside micrometer gauges","range":"14 mm to 500 mm","cmc":"(3L + 1) µm"},{"name":"Micrometer depth gauges","range":"14 mm to 500 mm","cmc":"(2L + 1,1) µm"},{"name":"Inside micrometers","range":"14 mm to 500 mm","cmc":"(2L + 1,1) µm"},{"name":"Micrometric heads","range":"0 mm to 500 mm","cmc":"(3L + 1) µm"}],"parameters_zh":[{"name":"内径测微杆","range":"14 mm 至 500 mm","cmc":"(3L + 1) µm"},{"name":"深度千分尺","range":"14 mm 至 500 mm","cmc":"(2L + 1,1) µm"},{"name":"内径千分尺","range":"14 mm 至 500 mm","cmc":"(2L + 1,1) µm"},{"name":"测微头","range":"0 mm 至 500 mm","cmc":"(3L + 1) µm"}],"parameters_cs":[{"name":"mikrometrické odpichy","range":"14 mm až 500 mm","cmc":"(3L + 1) µm"},{"name":"mikrometrické hloubkoměry","range":"14 mm až 500 mm","cmc":"(2L + 1,1) µm"},{"name":"mikrometry dutinové","range":"14 mm až 500 mm","cmc":"(2L + 1,1) µm"},{"name":"mikrometrická hlavice","range":"0 mm až 500 mm","cmc":"(3L + 1) µm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nśrednicówki mikrometryczne prętowe od 14 mm do 500 mm CMC (3L + 1) µm\ngłębokościomierze mikrometryczne od 14 mm do 500 mm CMC (2L + 1,1) µm\nmikrometry do otworów od 14 mm do 500 mm CMC (2L + 1,1) µm\ngłowica mikrometryczna od 0 mm do 500 mm CMC (3L + 1) µm\nPomiar za pomocą płytek wzorcowych","reference":"KPA-1.04","norm_bases":["KPA-1.04"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mikrometry do pomiarów wewnętrznych Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych średnicówki mikrometryczne prętowe od 14 mm do 500 mm CMC (3L + 1) µm głębokościomierze mikrometryczne od 14 mm do 500 mm CMC (2L + 1,1) µm mikrometry do otworów od 14 mm do 500 mm CMC (2L + 1,1) µm głowica mikrometryczna od 0 mm do 500 mm CMC (3L + 1) µm Mikrometry pro vnitřní měření Kalibrace – délka Měření pomocí koncových měrek mikrometrické odpichy 14 mm až 500 mm CMC (3L + 1) µm mikrometrické hloubkoměry 14 mm až 500 mm CMC (2L + 1,1) µm mikrometry dutinové 14 mm až 500 mm CMC (2L + 1,1) µm mikrometrická hlavice 0 mm až 500 mm CMC (3L + 1) µm KPA-1.04 Mikrometry do pomiarow wewnetrznych Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych srednicowki mikrometryczne pretowe od 14 mm do 500 mm CMC (3L + 1) µm glebokosciomierze mikrometryczne od 14 mm do 500 mm CMC (2L + 1,1) µm mikrometry do otworow od 14 mm do 500 mm CMC (2L + 1,1) µm glowica mikrometryczna od 0 mm do 500 mm CMC (3L + 1) µm Mikrometry pro vnitrni mereni Kalibrace – delka Mereni pomoci koncovych merek mikrometricke odpichy 14 mm az 500 mm CMC (3L + 1) µm mikrometricke hloubkomery 14 mm az 500 mm CMC (2L + 1,1) µm mikrometry dutinove 14 mm az 500 mm CMC (2L + 1,1) µm mikrometricka hlavice 0 mm az 500 mm CMC (3L + 1) µm KPA-1.04","search_en":"Micrometers for internal measurement Calibration – length Measurement using parallel gauge blocks Inside micrometer gauges 14 mm to 500 mm CMC (3L + 1) µm Micrometer depth gauges 14 mm to 500 mm CMC (2L + 1,1) µm Inside micrometers 14 mm to 500 mm CMC (2L + 1,1) µm Micrometric heads 0 mm to 500 mm CMC (3L + 1) µm KPA-1.04","search_zh":"内测千分尺 校准 – 长度 用量块测量 内径测微杆 14 mm 至 500 mm CMC (3L + 1) µm 深度千分尺 14 mm 至 500 mm CMC (2L + 1,1) µm 内径千分尺 14 mm 至 500 mm CMC (2L + 1,1) µm 测微头 0 mm 至 500 mm CMC (3L + 1) µm KPA-1.04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"04fb075e5e32bd4ca7bf1644","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"5","test_object":"Czujniki pomiarowe","test_object_en":"Deviation meters","test_object_zh":"指示表","test_object_cs":"Úchylkoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"zegarowe","range":"od 0 mm do 100 mm","cmc":"0,88 µm"},{"name":"dźwigniowe","range":"od 0 mm do 100 mm","cmc":"1,2 µm"},{"name":"somkatory","range":"od 0 mm do 100 mm","cmc":"1,2 µm"},{"name":"średnicówki czujnikowe","range":"od 0 mm do 100 mm","cmc":"1,2 µm"}],"parameters_en":[{"name":"Dial gauges","range":"0 mm to 100 mm","cmc":"0,88 µm"},{"name":"Pupitasts","range":"0 mm to 100 mm","cmc":"1,2 µm"},{"name":"Somcators","range":"0 mm to 100 mm","cmc":"1,2 µm"},{"name":"Internal gauges","range":"0 mm to 100 mm","cmc":"1,2 µm"}],"parameters_zh":[{"name":"百分表","range":"0 mm 至 100 mm","cmc":"0,88 µm"},{"name":"杠杆表","range":"0 mm 至 100 mm","cmc":"1,2 µm"},{"name":"扭簧比较仪","range":"0 mm 至 100 mm","cmc":"1,2 µm"},{"name":"内径表","range":"0 mm 至 100 mm","cmc":"1,2 µm"}],"parameters_cs":[{"name":"číselníkové","range":"0 mm až 100 mm","cmc":"0,88 µm"},{"name":"páčkové","range":"0 mm až 100 mm","cmc":"1,2 µm"},{"name":"somkátory","range":"0 mm až 100 mm","cmc":"1,2 µm"},{"name":"dutinoměry","range":"0 mm až 100 mm","cmc":"1,2 µm"}],"technique":"Pomiar na przyrządzie do wzorcowania czujników zegarowych","technique_en":"Measurement on a dial indicator calibration instrument","technique_zh":"在百分表校准仪上测量","technique_cs":"Měření na přístroji pro kalibrace číselníkových úchylkoměrů","techniques":["Pomiar na przyrządzie do wzorcowania czujników zegarowych"],"techniques_en":["Measurement on a dial indicator calibration instrument"],"techniques_zh":["在百分表校准仪上测量"],"techniques_cs":["Měření na přístroji pro kalibrace číselníkových úchylkoměrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nzegarowe od 0 mm do 100 mm CMC 0,88 µm\ndźwigniowe od 0 mm do 100 mm CMC 1,2 µm\nsomkatory od 0 mm do 100 mm CMC 1,2 µm\nśrednicówki czujnikowe od 0 mm do 100 mm CMC 1,2 µm\nPomiar na przyrządzie do wzorcowania czujników zegarowych","reference":"KPA-1.05","norm_bases":["KPA-1.05"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki pomiarowe Wzorcowanie – długość Pomiar na przyrządzie do wzorcowania czujników zegarowych zegarowe od 0 mm do 100 mm CMC 0,88 µm dźwigniowe od 0 mm do 100 mm CMC 1,2 µm somkatory od 0 mm do 100 mm CMC 1,2 µm średnicówki czujnikowe od 0 mm do 100 mm CMC 1,2 µm Úchylkoměry Kalibrace – délka Měření na přístroji pro kalibrace číselníkových úchylkoměrů číselníkové 0 mm až 100 mm CMC 0,88 µm páčkové 0 mm až 100 mm CMC 1,2 µm somkátory 0 mm až 100 mm CMC 1,2 µm dutinoměry 0 mm až 100 mm CMC 1,2 µm KPA-1.05 Czujniki pomiarowe Wzorcowanie – dlugosc Pomiar na przyrzadzie do wzorcowania czujnikow zegarowych zegarowe od 0 mm do 100 mm CMC 0,88 µm dzwigniowe od 0 mm do 100 mm CMC 1,2 µm somkatory od 0 mm do 100 mm CMC 1,2 µm srednicowki czujnikowe od 0 mm do 100 mm CMC 1,2 µm Uchylkomery Kalibrace – delka Mereni na pristroji pro kalibrace ciselnikovych uchylkomeru ciselnikove 0 mm az 100 mm CMC 0,88 µm packove 0 mm az 100 mm CMC 1,2 µm somkatory 0 mm az 100 mm CMC 1,2 µm dutinomery 0 mm az 100 mm CMC 1,2 µm KPA-1.05","search_en":"Deviation meters Calibration – length Measurement on a dial indicator calibration instrument Dial gauges 0 mm to 100 mm CMC 0,88 µm Pupitasts 0 mm to 100 mm CMC 1,2 µm Somcators 0 mm to 100 mm CMC 1,2 µm Internal gauges 0 mm to 100 mm CMC 1,2 µm KPA-1.05","search_zh":"指示表 校准 – 长度 在百分表校准仪上测量 百分表 0 mm 至 100 mm CMC 0,88 µm 杠杆表 0 mm 至 100 mm CMC 1,2 µm 扭簧比较仪 0 mm 至 100 mm CMC 1,2 µm 内径表 0 mm 至 100 mm CMC 1,2 µm KPA-1.05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e3ff28a5c6babcb1c4073ab","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"6","test_object":"Sprawdziany graniczne do pomiarów zewnętrznych","test_object_en":"Limit gauges for external measurement","test_object_zh":"外尺寸极限量规","test_object_cs":"Mezní kalibry pro vnější měření","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"szczękowe","range":"od 1 mm do 500 mm","cmc":"(3L + 1) µm"},{"name":"pierścienie gładkie","range":"od 1 mm do 500 mm","cmc":"(3,6L + 1,2) µm"},{"name":"pierścienie gwintowe","range":"od 1 mm do 500 mm","cmc":"(7,4L + 2,1) µm"}],"parameters_en":[{"name":"Snap gauges","range":"1 mm to 500 mm","cmc":"(3L + 1) µm"},{"name":"Plain rings","range":"1 mm to 500 mm","cmc":"(3,6L + 1,2) µm"},{"name":"Threaded rings","range":"1 mm to 500 mm","cmc":"(7,4L + 2,1) µm"}],"parameters_zh":[{"name":"卡规","range":"1 mm 至 500 mm","cmc":"(3L + 1) µm"},{"name":"光滑环规","range":"1 mm 至 500 mm","cmc":"(3,6L + 1,2) µm"},{"name":"螺纹环规","range":"1 mm 至 500 mm","cmc":"(7,4L + 2,1) µm"}],"parameters_cs":[{"name":"třmenové","range":"1 mm až 500 mm","cmc":"(3L + 1) µm"},{"name":"hladké kroužky","range":"1 mm až 500 mm","cmc":"(3,6L + 1,2) µm"},{"name":"závitové kroužky","range":"1 mm až 500 mm","cmc":"(7,4L + 2,1) µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nszczękowe od 1 mm do 500 mm CMC (3L + 1) µm\npierścienie gładkie od 1 mm do 500 mm CMC (3,6L + 1,2) µm\npierścienie gwintowe od 1 mm do 500 mm CMC (7,4L + 2,1) µm\nPomiar na długościomierzu","reference":"KPA-1.06","norm_bases":["KPA-1.06"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany graniczne do pomiarów zewnętrznych Wzorcowanie – długość Pomiar na długościomierzu szczękowe od 1 mm do 500 mm CMC (3L + 1) µm pierścienie gładkie od 1 mm do 500 mm CMC (3,6L + 1,2) µm pierścienie gwintowe od 1 mm do 500 mm CMC (7,4L + 2,1) µm Mezní kalibry pro vnější měření Kalibrace – délka Měření na délkoměru třmenové 1 mm až 500 mm CMC (3L + 1) µm hladké kroužky 1 mm až 500 mm CMC (3,6L + 1,2) µm závitové kroužky 1 mm až 500 mm CMC (7,4L + 2,1) µm KPA-1.06 Sprawdziany graniczne do pomiarow zewnetrznych Wzorcowanie – dlugosc Pomiar na dlugosciomierzu szczekowe od 1 mm do 500 mm CMC (3L + 1) µm pierscienie gladkie od 1 mm do 500 mm CMC (3,6L + 1,2) µm pierscienie gwintowe od 1 mm do 500 mm CMC (7,4L + 2,1) µm Mezni kalibry pro vnejsi mereni Kalibrace – delka Mereni na delkomeru trmenove 1 mm az 500 mm CMC (3L + 1) µm hladke krouzky 1 mm az 500 mm CMC (3,6L + 1,2) µm zavitove krouzky 1 mm az 500 mm CMC (7,4L + 2,1) µm KPA-1.06","search_en":"Limit gauges for external measurement Calibration – length Measurement on a length gauge Snap gauges 1 mm to 500 mm CMC (3L + 1) µm Plain rings 1 mm to 500 mm CMC (3,6L + 1,2) µm Threaded rings 1 mm to 500 mm CMC (7,4L + 2,1) µm KPA-1.06","search_zh":"外尺寸极限量规 校准 – 长度 在测长仪上测量 卡规 1 mm 至 500 mm CMC (3L + 1) µm 光滑环规 1 mm 至 500 mm CMC (3,6L + 1,2) µm 螺纹环规 1 mm 至 500 mm CMC (7,4L + 2,1) µm KPA-1.06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2815c23e4af6f013de016d0b","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"7","test_object":"Sprawdziany graniczne do pomiarów wewnętrznych","test_object_en":"Limit gauges for internal measurement","test_object_zh":"内尺寸极限量规","test_object_cs":"Mezní kalibry pro vnitřní měření","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"walcowe, płaskie","range":"od 0 mm do 500 mm","cmc":"(5,3L + 0,75) µm"},{"name":"gwintowe","range":"od 0 mm do 500 mm","cmc":"(2,8L + 2,8) µm"},{"name":"szczelinomierze","range":"od 0 mm do 500 mm","cmc":"3,6 µm"},{"name":"druciki pomiarowe","range":"od 0 mm do 500 mm","cmc":"0,54 µm"},{"name":"promieniomierze","range":"od 0 mm do 500 mm","cmc":"4,0 µm"},{"name":"wzorniki gwintów","range":"od 0 mm do 500 mm","cmc":"4,0 µm"},{"name":"wzorce grubości powłok lakierniczych","range":"od 0 mm do 500 mm","cmc":"1,4 µm"}],"parameters_en":[{"name":"cylinder, flat","range":"0 mm to 500 mm","cmc":"(5,3L + 0,75) µm"},{"name":"Thread gauges","range":"0 mm to 500 mm","cmc":"(2,8L + 2,8) µm"},{"name":"Feeler gauges","range":"0 mm to 500 mm","cmc":"3,6 µm"},{"name":"Measuring wires","range":"0 mm to 500 mm","cmc":"0,54 µm"},{"name":"Gauges for radius","range":"0 mm to 500 mm","cmc":"4,0 µm"},{"name":"Gauges for threads","range":"0 mm to 500 mm","cmc":"4,0 µm"},{"name":"Gauges for paint thickness","range":"0 mm to 500 mm","cmc":"1,4 µm"}],"parameters_zh":[{"name":"圆柱形、扁平形","range":"0 mm 至 500 mm","cmc":"(5,3L + 0,75) µm"},{"name":"螺纹量规","range":"0 mm 至 500 mm","cmc":"(2,8L + 2,8) µm"},{"name":"塞尺","range":"0 mm 至 500 mm","cmc":"3,6 µm"},{"name":"测量针","range":"0 mm 至 500 mm","cmc":"0,54 µm"},{"name":"半径样板","range":"0 mm 至 500 mm","cmc":"4,0 µm"},{"name":"螺纹样板","range":"0 mm 至 500 mm","cmc":"4,0 µm"},{"name":"漆膜厚度量规","range":"0 mm 至 500 mm","cmc":"1,4 µm"}],"parameters_cs":[{"name":"válečkové, ploché","range":"0 mm až 500 mm","cmc":"(5,3L + 0,75) µm"},{"name":"závitové","range":"0 mm až 500 mm","cmc":"(2,8L + 2,8) µm"},{"name":"spároměry","range":"0 mm až 500 mm","cmc":"3,6 µm"},{"name":"měřící drátky","range":"0 mm až 500 mm","cmc":"0,54 µm"},{"name":"poloměrové šablony","range":"0 mm až 500 mm","cmc":"4,0 µm"},{"name":"závitové šablony","range":"0 mm až 500 mm","cmc":"4,0 µm"},{"name":"měrky na tloušťku barev","range":"0 mm až 500 mm","cmc":"1,4 µm"}],"technique":"Pomiar na długościomierzu","technique_en":"Measurement on a length gauge","technique_zh":"在测长仪上测量","technique_cs":"Měření na délkoměru","techniques":["Pomiar na długościomierzu"],"techniques_en":["Measurement on a length gauge"],"techniques_zh":["在测长仪上测量"],"techniques_cs":["Měření na délkoměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nwalcowe, płaskie od 0 mm do 500 mm CMC (5,3L + 0,75) µm\ngwintowe od 0 mm do 500 mm CMC (2,8L + 2,8) µm\nszczelinomierze od 0 mm do 500 mm CMC 3,6 µm\ndruciki pomiarowe od 0 mm do 500 mm CMC 0,54 µm\npromieniomierze od 0 mm do 500 mm CMC 4,0 µm\nwzorniki gwintów od 0 mm do 500 mm CMC 4,0 µm\nwzorce grubości powłok lakierniczych od 0 mm do 500 mm CMC 1,4 µm\nPomiar na długościomierzu","reference":"KPA-1.07","norm_bases":["KPA-1.07"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany graniczne do pomiarów wewnętrznych Wzorcowanie – długość Pomiar na długościomierzu walcowe, płaskie od 0 mm do 500 mm CMC (5,3L + 0,75) µm gwintowe od 0 mm do 500 mm CMC (2,8L + 2,8) µm szczelinomierze od 0 mm do 500 mm CMC 3,6 µm druciki pomiarowe od 0 mm do 500 mm CMC 0,54 µm promieniomierze od 0 mm do 500 mm CMC 4,0 µm wzorniki gwintów od 0 mm do 500 mm CMC 4,0 µm wzorce grubości powłok lakierniczych od 0 mm do 500 mm CMC 1,4 µm Mezní kalibry pro vnitřní měření Kalibrace – délka Měření na délkoměru válečkové, ploché 0 mm až 500 mm CMC (5,3L + 0,75) µm závitové 0 mm až 500 mm CMC (2,8L + 2,8) µm spároměry 0 mm až 500 mm CMC 3,6 µm měřící drátky 0 mm až 500 mm CMC 0,54 µm poloměrové šablony 0 mm až 500 mm CMC 4,0 µm závitové šablony 0 mm až 500 mm CMC 4,0 µm měrky na tloušťku barev 0 mm až 500 mm CMC 1,4 µm KPA-1.07 Sprawdziany graniczne do pomiarow wewnetrznych Wzorcowanie – dlugosc Pomiar na dlugosciomierzu walcowe, plaskie od 0 mm do 500 mm CMC (5,3L + 0,75) µm gwintowe od 0 mm do 500 mm CMC (2,8L + 2,8) µm szczelinomierze od 0 mm do 500 mm CMC 3,6 µm druciki pomiarowe od 0 mm do 500 mm CMC 0,54 µm promieniomierze od 0 mm do 500 mm CMC 4,0 µm wzorniki gwintow od 0 mm do 500 mm CMC 4,0 µm wzorce grubosci powlok lakierniczych od 0 mm do 500 mm CMC 1,4 µm Mezni kalibry pro vnitrni mereni Kalibrace – delka Mereni na delkomeru valeckove, ploche 0 mm az 500 mm CMC (5,3L + 0,75) µm zavitove 0 mm az 500 mm CMC (2,8L + 2,8) µm sparomery 0 mm az 500 mm CMC 3,6 µm merici dratky 0 mm az 500 mm CMC 0,54 µm polomerove sablony 0 mm az 500 mm CMC 4,0 µm zavitove sablony 0 mm az 500 mm CMC 4,0 µm merky na tloustku barev 0 mm az 500 mm CMC 1,4 µm KPA-1.07","search_en":"Limit gauges for internal measurement Calibration – length Measurement on a length gauge cylinder, flat 0 mm to 500 mm CMC (5,3L + 0,75) µm Thread gauges 0 mm to 500 mm CMC (2,8L + 2,8) µm Feeler gauges 0 mm to 500 mm CMC 3,6 µm Measuring wires 0 mm to 500 mm CMC 0,54 µm Gauges for radius 0 mm to 500 mm CMC 4,0 µm Gauges for threads 0 mm to 500 mm CMC 4,0 µm Gauges for paint thickness 0 mm to 500 mm CMC 1,4 µm KPA-1.07","search_zh":"内尺寸极限量规 校准 – 长度 在测长仪上测量 圆柱形、扁平形 0 mm 至 500 mm CMC (5,3L + 0,75) µm 螺纹量规 0 mm 至 500 mm CMC (2,8L + 2,8) µm 塞尺 0 mm 至 500 mm CMC 3,6 µm 测量针 0 mm 至 500 mm CMC 0,54 µm 半径样板 0 mm 至 500 mm CMC 4,0 µm 螺纹样板 0 mm 至 500 mm CMC 4,0 µm 漆膜厚度量规 0 mm 至 500 mm CMC 1,4 µm KPA-1.07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b99e98e20da3b6f578742f97","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"8","test_object":"Przyrządy kreskowe","test_object_en":"Rules","test_object_zh":"刻线量具","test_object_cs":"Čárková měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"przymiary stalowe","range":"od 0 mm do 10000 mm","cmc":"(4,6L + 4,7) µm"},{"name":"lupa pomiarowa","range":"od 0 mm do 100 mm","cmc":"(4,6L + 4,7) µm"}],"parameters_en":[{"name":"Steel rules","range":"0 mm to 10000 mm","cmc":"(4,6L + 4,7) µm"},{"name":"Measuring magnifier","range":"0 mm to 100 mm","cmc":"(4,6L + 4,7) µm"}],"parameters_zh":[{"name":"钢直尺","range":"0 mm 至 10000 mm","cmc":"(4,6L + 4,7) µm"},{"name":"测量放大镜","range":"0 mm 至 100 mm","cmc":"(4,6L + 4,7) µm"}],"parameters_cs":[{"name":"ocelová měřítka","range":"0 mm až 10000 mm","cmc":"(4,6L + 4,7) µm"},{"name":"měřicí lupa","range":"0 mm až 100 mm","cmc":"(4,6L + 4,7) µm"}],"technique":"Pomiar na współrzędnościowej maszynie pomiarowej","technique_en":"Measurement on a coordinate measuring machine","technique_zh":"在坐标测量机上测量","technique_cs":"Měření na souřadnicovém měřícím stroji","techniques":["Pomiar na współrzędnościowej maszynie pomiarowej"],"techniques_en":["Measurement on a coordinate measuring machine"],"techniques_zh":["在坐标测量机上测量"],"techniques_cs":["Měření na souřadnicovém měřícím stroji"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nprzymiary stalowe od 0 mm do 10000 mm CMC (4,6L + 4,7) µm\nlupa pomiarowa od 0 mm do 100 mm CMC (4,6L + 4,7) µm\nPomiar na współrzędnościowej maszynie pomiarowej","reference":"KPA-1.08","norm_bases":["KPA-1.08"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy kreskowe Wzorcowanie – długość Pomiar na współrzędnościowej maszynie pomiarowej przymiary stalowe od 0 mm do 10000 mm CMC (4,6L + 4,7) µm lupa pomiarowa od 0 mm do 100 mm CMC (4,6L + 4,7) µm Čárková měřidla Kalibrace – délka Měření na souřadnicovém měřícím stroji ocelová měřítka 0 mm až 10000 mm CMC (4,6L + 4,7) µm měřicí lupa 0 mm až 100 mm CMC (4,6L + 4,7) µm KPA-1.08 Przyrzady kreskowe Wzorcowanie – dlugosc Pomiar na wspolrzednosciowej maszynie pomiarowej przymiary stalowe od 0 mm do 10000 mm CMC (4,6L + 4,7) µm lupa pomiarowa od 0 mm do 100 mm CMC (4,6L + 4,7) µm Carkova meridla Kalibrace – delka Mereni na souradnicovem mericim stroji ocelova meritka 0 mm az 10000 mm CMC (4,6L + 4,7) µm merici lupa 0 mm az 100 mm CMC (4,6L + 4,7) µm KPA-1.08","search_en":"Rules Calibration – length Measurement on a coordinate measuring machine Steel rules 0 mm to 10000 mm CMC (4,6L + 4,7) µm Measuring magnifier 0 mm to 100 mm CMC (4,6L + 4,7) µm KPA-1.08","search_zh":"刻线量具 校准 – 长度 在坐标测量机上测量 钢直尺 0 mm 至 10000 mm CMC (4,6L + 4,7) µm 测量放大镜 0 mm 至 100 mm CMC (4,6L + 4,7) µm KPA-1.08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ee8e3f2de524bcf61439fe0d","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"8","test_object":"Przyrządy kreskowe","test_object_en":"Rules","test_object_zh":"刻线量具","test_object_cs":"Čárková měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"przymiary stalowe","range":"od 0 mm do 10000 mm","cmc":"(4,6L + 4,7) µm"},{"name":"lupa pomiarowa","range":"od 0 mm do 100 mm","cmc":"(4,6L + 4,7) µm"}],"parameters_en":[{"name":"Steel rules","range":"0 mm to 10000 mm","cmc":"(4,6L + 4,7) µm"},{"name":"Measuring magnifier","range":"0 mm to 100 mm","cmc":"(4,6L + 4,7) µm"}],"parameters_zh":[{"name":"钢直尺","range":"0 mm 至 10000 mm","cmc":"(4,6L + 4,7) µm"},{"name":"测量放大镜","range":"0 mm 至 100 mm","cmc":"(4,6L + 4,7) µm"}],"parameters_cs":[{"name":"ocelová měřítka","range":"0 mm až 10000 mm","cmc":"(4,6L + 4,7) µm"},{"name":"měřicí lupa","range":"0 mm až 100 mm","cmc":"(4,6L + 4,7) µm"}],"technique":"Pomiar na współrzędnościowej maszynie pomiarowej","technique_en":"Measurement on a coordinate measuring machine","technique_zh":"在坐标测量机上测量","technique_cs":"Měření na souřadnicovém měřícím stroji","techniques":["Pomiar na współrzędnościowej maszynie pomiarowej"],"techniques_en":["Measurement on a coordinate measuring machine"],"techniques_zh":["在坐标测量机上测量"],"techniques_cs":["Měření na souřadnicovém měřícím stroji"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nprzymiary stalowe od 0 mm do 10000 mm CMC (4,6L + 4,7) µm\nlupa pomiarowa od 0 mm do 100 mm CMC (4,6L + 4,7) µm\nPomiar na współrzędnościowej maszynie pomiarowej","reference":"KPA-1.08","norm_bases":["KPA-1.08"],"lab_section":"Pracownia Vlčí Habřina","lab_section_en":"Workplace Vlčí Habřina","lab_section_zh":"Vlčí Habřina 工作场所","lab_section_cs":"Pracoviště Vlčí Habřina","lab_address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy kreskowe Wzorcowanie – długość Pomiar na współrzędnościowej maszynie pomiarowej przymiary stalowe od 0 mm do 10000 mm CMC (4,6L + 4,7) µm lupa pomiarowa od 0 mm do 100 mm CMC (4,6L + 4,7) µm Čárková měřidla Kalibrace – délka Měření na souřadnicovém měřícím stroji ocelová měřítka 0 mm až 10000 mm CMC (4,6L + 4,7) µm měřicí lupa 0 mm až 100 mm CMC (4,6L + 4,7) µm KPA-1.08 Przyrzady kreskowe Wzorcowanie – dlugosc Pomiar na wspolrzednosciowej maszynie pomiarowej przymiary stalowe od 0 mm do 10000 mm CMC (4,6L + 4,7) µm lupa pomiarowa od 0 mm do 100 mm CMC (4,6L + 4,7) µm Carkova meridla Kalibrace – delka Mereni na souradnicovem mericim stroji ocelova meritka 0 mm az 10000 mm CMC (4,6L + 4,7) µm merici lupa 0 mm az 100 mm CMC (4,6L + 4,7) µm KPA-1.08","search_en":"Rules Calibration – length Measurement on a coordinate measuring machine Steel rules 0 mm to 10000 mm CMC (4,6L + 4,7) µm Measuring magnifier 0 mm to 100 mm CMC (4,6L + 4,7) µm KPA-1.08","search_zh":"刻线量具 校准 – 长度 在坐标测量机上测量 钢直尺 0 mm 至 10000 mm CMC (4,6L + 4,7) µm 测量放大镜 0 mm 至 100 mm CMC (4,6L + 4,7) µm KPA-1.08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0250ee07d8de0106b821d204","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"8","test_object":"Przyrządy kreskowe","test_object_en":"Rules","test_object_zh":"刻线量具","test_object_cs":"Čárková měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"stalowe taśmy miernicze zwijane","range":"od 0 mm do 10000 mm","cmc":"(3,8L + 140) µm"},{"name":"taśmy miernicze","range":"od 0 m do 100 m","cmc":"(0,06L + 0,3) mm"}],"parameters_en":[{"name":"Steel tape measures","range":"0 mm to 10000 mm","cmc":"(3,8L + 140) µm"},{"name":"Tapes","range":"0 m to 100 m","cmc":"(0,06L + 0,3) mm"}],"parameters_zh":[{"name":"钢卷尺","range":"0 mm 至 10000 mm","cmc":"(3,8L + 140) µm"},{"name":"卷尺","range":"0 m 至 100 m","cmc":"(0,06L + 0,3) mm"}],"parameters_cs":[{"name":"ocelové svinovací metry","range":"0 mm až 10000 mm","cmc":"(3,8L + 140) µm"},{"name":"pásma","range":"0 m až 100 m","cmc":"(0,06L + 0,3) mm"}],"technique":"Porównanie z przymiarem stalowym","technique_en":"Comparison with a steel gauge","technique_zh":"与钢直尺比较","technique_cs":"Porovnání s ocelovým měřítkem","techniques":["Porównanie z przymiarem stalowym"],"techniques_en":["Comparison with a steel gauge"],"techniques_zh":["与钢直尺比较"],"techniques_cs":["Porovnání s ocelovým měřítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nstalowe taśmy miernicze zwijane od 0 mm do 10000 mm CMC (3,8L + 140) µm\ntaśmy miernicze od 0 m do 100 m CMC (0,06L + 0,3) mm\nPorównanie z przymiarem stalowym","reference":"KPA-1.08","norm_bases":["KPA-1.08"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy kreskowe Wzorcowanie – długość Porównanie z przymiarem stalowym stalowe taśmy miernicze zwijane od 0 mm do 10000 mm CMC (3,8L + 140) µm taśmy miernicze od 0 m do 100 m CMC (0,06L + 0,3) mm Čárková měřidla Kalibrace – délka Porovnání s ocelovým měřítkem ocelové svinovací metry 0 mm až 10000 mm CMC (3,8L + 140) µm pásma 0 m až 100 m CMC (0,06L + 0,3) mm KPA-1.08 Przyrzady kreskowe Wzorcowanie – dlugosc Porownanie z przymiarem stalowym stalowe tasmy miernicze zwijane od 0 mm do 10000 mm CMC (3,8L + 140) µm tasmy miernicze od 0 m do 100 m CMC (0,06L + 0,3) mm Carkova meridla Kalibrace – delka Porovnani s ocelovym meritkem ocelove svinovaci metry 0 mm az 10000 mm CMC (3,8L + 140) µm pasma 0 m az 100 m CMC (0,06L + 0,3) mm KPA-1.08","search_en":"Rules Calibration – length Comparison with a steel gauge Steel tape measures 0 mm to 10000 mm CMC (3,8L + 140) µm Tapes 0 m to 100 m CMC (0,06L + 0,3) mm KPA-1.08","search_zh":"刻线量具 校准 – 长度 与钢直尺比较 钢卷尺 0 mm 至 10000 mm CMC (3,8L + 140) µm 卷尺 0 m 至 100 m CMC (0,06L + 0,3) mm KPA-1.08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"608760585a7cd990bb4d0081","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"8","test_object":"Przyrządy kreskowe","test_object_en":"Rules","test_object_zh":"刻线量具","test_object_cs":"Čárková měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"stalowe taśmy miernicze zwijane","range":"od 0 mm do 10000 mm","cmc":"(3,8L + 140) µm"},{"name":"taśmy miernicze","range":"od 0 m do 100 m","cmc":"(0,06L + 0,3) mm"}],"parameters_en":[{"name":"Steel tape measures","range":"0 mm to 10000 mm","cmc":"(3,8L + 140) µm"},{"name":"Tapes","range":"0 m to 100 m","cmc":"(0,06L + 0,3) mm"}],"parameters_zh":[{"name":"钢卷尺","range":"0 mm 至 10000 mm","cmc":"(3,8L + 140) µm"},{"name":"卷尺","range":"0 m 至 100 m","cmc":"(0,06L + 0,3) mm"}],"parameters_cs":[{"name":"ocelové svinovací metry","range":"0 mm až 10000 mm","cmc":"(3,8L + 140) µm"},{"name":"pásma","range":"0 m až 100 m","cmc":"(0,06L + 0,3) mm"}],"technique":"Porównanie z przymiarem stalowym","technique_en":"Comparison with a steel gauge","technique_zh":"与钢直尺比较","technique_cs":"Porovnání s ocelovým měřítkem","techniques":["Porównanie z przymiarem stalowym"],"techniques_en":["Comparison with a steel gauge"],"techniques_zh":["与钢直尺比较"],"techniques_cs":["Porovnání s ocelovým měřítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nstalowe taśmy miernicze zwijane od 0 mm do 10000 mm CMC (3,8L + 140) µm\ntaśmy miernicze od 0 m do 100 m CMC (0,06L + 0,3) mm\nPorównanie z przymiarem stalowym","reference":"KPA-1.08","norm_bases":["KPA-1.08"],"lab_section":"Pracownia Vlčí Habřina","lab_section_en":"Workplace Vlčí Habřina","lab_section_zh":"Vlčí Habřina 工作场所","lab_section_cs":"Pracoviště Vlčí Habřina","lab_address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy kreskowe Wzorcowanie – długość Porównanie z przymiarem stalowym stalowe taśmy miernicze zwijane od 0 mm do 10000 mm CMC (3,8L + 140) µm taśmy miernicze od 0 m do 100 m CMC (0,06L + 0,3) mm Čárková měřidla Kalibrace – délka Porovnání s ocelovým měřítkem ocelové svinovací metry 0 mm až 10000 mm CMC (3,8L + 140) µm pásma 0 m až 100 m CMC (0,06L + 0,3) mm KPA-1.08 Przyrzady kreskowe Wzorcowanie – dlugosc Porownanie z przymiarem stalowym stalowe tasmy miernicze zwijane od 0 mm do 10000 mm CMC (3,8L + 140) µm tasmy miernicze od 0 m do 100 m CMC (0,06L + 0,3) mm Carkova meridla Kalibrace – delka Porovnani s ocelovym meritkem ocelove svinovaci metry 0 mm az 10000 mm CMC (3,8L + 140) µm pasma 0 m az 100 m CMC (0,06L + 0,3) mm KPA-1.08","search_en":"Rules Calibration – length Comparison with a steel gauge Steel tape measures 0 mm to 10000 mm CMC (3,8L + 140) µm Tapes 0 m to 100 m CMC (0,06L + 0,3) mm KPA-1.08","search_zh":"刻线量具 校准 – 长度 与钢直尺比较 钢卷尺 0 mm 至 10000 mm CMC (3,8L + 140) µm 卷尺 0 m 至 100 m CMC (0,06L + 0,3) mm KPA-1.08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"db4d23c98b5da01fd7272242","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"9","test_object":"Przyrządy dwuwspółrzędnościowe, mikroskopy pomiarowe, projektory profilowe","test_object_en":"Two-coordinate measuring machines, Measuring microscopes, Profile projectors","test_object_zh":"二坐标测量仪、测量显微镜、轮廓投影仪","test_object_cs":"Dvousouřadnicové přístroje, měřicí mikroskopy, profilprojektory","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"3,2 µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"3,2 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"3,2 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"3,2 µm"}],"technique":"Pomiar za pomocą liniału szklanego","technique_en":"Measuring with a glass ruler","technique_zh":"用玻璃尺测量","technique_cs":"Měření pomocí skleněného pravítka","techniques":["Pomiar za pomocą liniału szklanego"],"techniques_en":["Measuring with a glass ruler"],"techniques_zh":["用玻璃尺测量"],"techniques_cs":["Měření pomocí skleněného pravítka"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC 3,2 µm\nPomiar za pomocą liniału szklanego","reference":"KPA-1.09","norm_bases":["KPA-1.09"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy dwuwspółrzędnościowe, mikroskopy pomiarowe, projektory profilowe Wzorcowanie – długość Pomiar za pomocą liniału szklanego od 0 mm do 1000 mm CMC 3,2 µm Dvousouřadnicové přístroje, měřicí mikroskopy, profilprojektory Kalibrace – délka Měření pomocí skleněného pravítka 0 mm až 1000 mm CMC 3,2 µm KPA-1.09 Przyrzady dwuwspolrzednosciowe, mikroskopy pomiarowe, projektory profilowe Wzorcowanie – dlugosc Pomiar za pomoca linialu szklanego od 0 mm do 1000 mm CMC 3,2 µm Dvousouradnicove pristroje, merici mikroskopy, profilprojektory Kalibrace – delka Mereni pomoci skleneneho pravitka 0 mm az 1000 mm CMC 3,2 µm KPA-1.09","search_en":"Two-coordinate measuring machines, Measuring microscopes, Profile projectors Calibration – length Measuring with a glass ruler 0 mm to 1000 mm CMC 3,2 µm KPA-1.09","search_zh":"二坐标测量仪、测量显微镜、轮廓投影仪 校准 – 长度 用玻璃尺测量 0 mm 至 1000 mm CMC 3,2 µm KPA-1.09","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2da0ba5a299ca9165b6bf2b7","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"10","test_object":"Nietypowe przyrządy do pomiaru długości","test_object_en":"Atypical length gauges","test_object_zh":"非标准长度量具","test_object_cs":"Atypická měřidla délky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 250 mm","cmc":"4,0 µm"}],"parameters_en":[{"name":"","range":"0 mm to 250 mm","cmc":"4,0 µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 250 mm","cmc":"4,0 µm"}],"parameters_cs":[{"name":"","range":"0 mm až 250 mm","cmc":"4,0 µm"}],"technique":"Pomiar na współrzędnościowej maszynie pomiarowej","technique_en":"Measurement on a coordinate measuring machine","technique_zh":"在坐标测量机上测量","technique_cs":"Měření na souřadnicovém měřícím stroji","techniques":["Pomiar na współrzędnościowej maszynie pomiarowej"],"techniques_en":["Measurement on a coordinate measuring machine"],"techniques_zh":["在坐标测量机上测量"],"techniques_cs":["Měření na souřadnicovém měřícím stroji"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 250 mm CMC 4,0 µm\nPomiar na współrzędnościowej maszynie pomiarowej","reference":"KPA-1.10","norm_bases":["KPA-1.10"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nietypowe przyrządy do pomiaru długości Wzorcowanie – długość Pomiar na współrzędnościowej maszynie pomiarowej od 0 mm do 250 mm CMC 4,0 µm Atypická měřidla délky Kalibrace – délka Měření na souřadnicovém měřícím stroji 0 mm až 250 mm CMC 4,0 µm KPA-1.10 Nietypowe przyrzady do pomiaru dlugosci Wzorcowanie – dlugosc Pomiar na wspolrzednosciowej maszynie pomiarowej od 0 mm do 250 mm CMC 4,0 µm Atypicka meridla delky Kalibrace – delka Mereni na souradnicovem mericim stroji 0 mm az 250 mm CMC 4,0 µm KPA-1.10","search_en":"Atypical length gauges Calibration – length Measurement on a coordinate measuring machine 0 mm to 250 mm CMC 4,0 µm KPA-1.10","search_zh":"非标准长度量具 校准 – 长度 在坐标测量机上测量 0 mm 至 250 mm CMC 4,0 µm KPA-1.10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ab0377b31f3d521dbb52047","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"11","test_object":"Płyty pomiarowe, pryzmy, podkładki (dłuższy bok do 5000 mm)","test_object_en":"Surface plates, blocks, plates (longer side up to 5,000 mm)","test_object_zh":"平板、方箱、垫板（长边至 5000 mm）","test_object_cs":"Příměrné desky, hranoly, podložky (delší strana do 5000 mm)","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"płaskość, prostoliniowość","range":"od 0 mm do 10 mm","cmc":"3,8 µm"}],"parameters_en":[{"name":"flatness, straightness","range":"0 mm to 10 mm","cmc":"3,8 µm"}],"parameters_zh":[{"name":"平面度、直线度","range":"0 mm 至 10 mm","cmc":"3,8 µm"}],"parameters_cs":[{"name":"rovinnost, přímost","range":"0 mm až 10 mm","cmc":"3,8 µm"}],"technique":"Pomiar poziomnicą elektroniczną","technique_en":"Measurement by an electronic level","technique_zh":"用电子水平仪测量","technique_cs":"Měření elektronickou libelou","techniques":["Pomiar poziomnicą elektroniczną"],"techniques_en":["Measurement by an electronic level"],"techniques_zh":["用电子水平仪测量"],"techniques_cs":["Měření elektronickou libelou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\npłaskość, prostoliniowość od 0 mm do 10 mm CMC 3,8 µm\nPomiar poziomnicą elektroniczną","reference":"KPA-1.13","norm_bases":["KPA-1.13"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płyty pomiarowe, pryzmy, podkładki (dłuższy bok do 5000 mm) Wzorcowanie – długość Pomiar poziomnicą elektroniczną płaskość, prostoliniowość od 0 mm do 10 mm CMC 3,8 µm Příměrné desky, hranoly, podložky (delší strana do 5000 mm) Kalibrace – délka Měření elektronickou libelou rovinnost, přímost 0 mm až 10 mm CMC 3,8 µm KPA-1.13 Plyty pomiarowe, pryzmy, podkladki (dluzszy bok do 5000 mm) Wzorcowanie – dlugosc Pomiar poziomnica elektroniczna plaskosc, prostoliniowosc od 0 mm do 10 mm CMC 3,8 µm Primerne desky, hranoly, podlozky (delsi strana do 5000 mm) Kalibrace – delka Mereni elektronickou libelou rovinnost, primost 0 mm az 10 mm CMC 3,8 µm KPA-1.13","search_en":"Surface plates, blocks, plates (longer side up to 5,000 mm) Calibration – length Measurement by an electronic level flatness, straightness 0 mm to 10 mm CMC 3,8 µm KPA-1.13","search_zh":"平板、方箱、垫板（长边至 5000 mm） 校准 – 长度 用电子水平仪测量 平面度、直线度 0 mm 至 10 mm CMC 3,8 µm KPA-1.13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"30ed72f1f1b0c16952ebcc27","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"12","test_object":"Długościomierze","test_object_en":"Length gauges","test_object_zh":"测长仪","test_object_cs":"Délkoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"(2L + 0,25) µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"(2L + 0,25) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(2L + 0,25) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"(2L + 0,25) µm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC (2L + 0,25) µm\nPorównanie z płytkami wzorcowymi","reference":"KPA-1.14","norm_bases":["KPA-1.14"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długościomierze Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 1000 mm CMC (2L + 0,25) µm Délkoměry Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 1000 mm CMC (2L + 0,25) µm KPA-1.14 Dlugosciomierze Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 1000 mm CMC (2L + 0,25) µm Delkomery Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 1000 mm CMC (2L + 0,25) µm KPA-1.14","search_en":"Length gauges Calibration – length Comparison with parallel gauge blocks 0 mm to 1000 mm CMC (2L + 0,25) µm KPA-1.14","search_zh":"测长仪 校准 – 长度 与量块比较 0 mm 至 1000 mm CMC (2L + 0,25) µm KPA-1.14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e39b9f4bea909a46b25f4097","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Wzorce kąta stałe","test_object_en":"Rigid angle gauges","test_object_zh":"固定角度量具","test_object_cs":"Měřidla úhlu pevná","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"kątowniki kontrolne – kąt między ramionami","range":"od 0° do 180°","cmc":"32 µm/m"},{"name":"sprawdziany stożkowe","range":"od 0° do 90°","cmc":"7´´"}],"parameters_en":[{"name":"check squares – angle between arms","range":"0° to 180°","cmc":"32 µm/m"},{"name":"taper gauges","range":"0° to 90°","cmc":"7´´"}],"parameters_zh":[{"name":"检验角尺 – 两臂间夹角","range":"0° 至 180°","cmc":"32 µm/m"},{"name":"锥度量规","range":"0° 至 90°","cmc":"7´´"}],"parameters_cs":[{"name":"kontrolní úhelníky – úhel mezi rameny","range":"0° až 180°","cmc":"32 µm/m"},{"name":"kuželové kalibry","range":"0° až 90°","cmc":"7´´"}],"technique":"Pomiar na współrzędnościowej maszynie pomiarowej","technique_en":"Measurement on a coordinate measuring machine","technique_zh":"在坐标测量机上测量","technique_cs":"Měření na souřadnicovém měřícím stroji","techniques":["Pomiar na współrzędnościowej maszynie pomiarowej"],"techniques_en":["Measurement on a coordinate measuring machine"],"techniques_zh":["在坐标测量机上测量"],"techniques_cs":["Měření na souřadnicovém měřícím stroji"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nZakres:\nkątowniki kontrolne – kąt między ramionami od 0° do 180° CMC 32 µm/m\nsprawdziany stożkowe od 0° do 90° CMC 7´´\nPomiar na współrzędnościowej maszynie pomiarowej","reference":"KPA-1.11","norm_bases":["KPA-1.11"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorce kąta stałe Wzorcowanie – kąt płaski Pomiar na współrzędnościowej maszynie pomiarowej kątowniki kontrolne – kąt między ramionami od 0° do 180° CMC 32 µm/m sprawdziany stożkowe od 0° do 90° CMC 7´´ Měřidla úhlu pevná Kalibrace – rovinný úhel Měření na souřadnicovém měřícím stroji kontrolní úhelníky – úhel mezi rameny 0° až 180° CMC 32 µm/m kuželové kalibry 0° až 90° CMC 7´´ KPA-1.11 Wzorce kata stale Wzorcowanie – kat plaski Pomiar na wspolrzednosciowej maszynie pomiarowej katowniki kontrolne – kat miedzy ramionami od 0° do 180° CMC 32 µm/m sprawdziany stozkowe od 0° do 90° CMC 7´´ Meridla uhlu pevna Kalibrace – rovinny uhel Mereni na souradnicovem mericim stroji kontrolni uhelniky – uhel mezi rameny 0° az 180° CMC 32 µm/m kuzelove kalibry 0° az 90° CMC 7´´ KPA-1.11","search_en":"Rigid angle gauges Calibration – plane angle Measurement on a coordinate measuring machine check squares – angle between arms 0° to 180° CMC 32 µm/m taper gauges 0° to 90° CMC 7´´ KPA-1.11","search_zh":"固定角度量具 校准 – 平面角 在坐标测量机上测量 检验角尺 – 两臂间夹角 0° 至 180° CMC 32 µm/m 锥度量规 0° 至 90° CMC 7´´ KPA-1.11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1d5e81046cc9496d6fdbaab2","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Wzorce kąta stałe","test_object_en":"Rigid angle gauges","test_object_zh":"固定角度量具","test_object_cs":"Měřidla úhlu pevná","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"kątowniki środkujące","range":"od 0° do 90°","cmc":"32 µm/m"},{"name":"wzorniki gwintów","range":"od 0° do 90°","cmc":"7´´"}],"parameters_en":[{"name":"centre squares","range":"0° to 90°","cmc":"32 µm/m"},{"name":"gauges for threads","range":"0° to 90°","cmc":"7´´"}],"parameters_zh":[{"name":"定心角尺","range":"0° 至 90°","cmc":"32 µm/m"},{"name":"螺纹样板","range":"0° 至 90°","cmc":"7´´"}],"parameters_cs":[{"name":"středicí úhelníky","range":"0° až 90°","cmc":"32 µm/m"},{"name":"závitové šablony","range":"0° až 90°","cmc":"7´´"}],"technique":"Pomiar na generatorze małych kątów","technique_en":"Measurement on a small angle generator","technique_zh":"在小角度发生器上测量","technique_cs":"Měření na generátoru malých úhlů","techniques":["Pomiar na generatorze małych kątów"],"techniques_en":["Measurement on a small angle generator"],"techniques_zh":["在小角度发生器上测量"],"techniques_cs":["Měření na generátoru malých úhlů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nZakres:\nkątowniki środkujące od 0° do 90° CMC 32 µm/m\nwzorniki gwintów od 0° do 90° CMC 7´´\nPomiar na generatorze małych kątów","reference":"KPA-1.11","norm_bases":["KPA-1.11"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorce kąta stałe Wzorcowanie – kąt płaski Pomiar na generatorze małych kątów kątowniki środkujące od 0° do 90° CMC 32 µm/m wzorniki gwintów od 0° do 90° CMC 7´´ Měřidla úhlu pevná Kalibrace – rovinný úhel Měření na generátoru malých úhlů středicí úhelníky 0° až 90° CMC 32 µm/m závitové šablony 0° až 90° CMC 7´´ KPA-1.11 Wzorce kata stale Wzorcowanie – kat plaski Pomiar na generatorze malych katow katowniki srodkujace od 0° do 90° CMC 32 µm/m wzorniki gwintow od 0° do 90° CMC 7´´ Meridla uhlu pevna Kalibrace – rovinny uhel Mereni na generatoru malych uhlu stredici uhelniky 0° az 90° CMC 32 µm/m zavitove sablony 0° az 90° CMC 7´´ KPA-1.11","search_en":"Rigid angle gauges Calibration – plane angle Measurement on a small angle generator centre squares 0° to 90° CMC 32 µm/m gauges for threads 0° to 90° CMC 7´´ KPA-1.11","search_zh":"固定角度量具 校准 – 平面角 在小角度发生器上测量 定心角尺 0° 至 90° CMC 32 µm/m 螺纹样板 0° 至 90° CMC 7´´ KPA-1.11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"483403c02c8e74a6de3e72b9","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"2","test_object":"Kątomierze","test_object_en":"Angle gauges","test_object_zh":"角度尺","test_object_cs":"Úhloměry","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0° do 360°","cmc":"1,8´"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"1,8´"}],"parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"1,8´"}],"parameters_cs":[{"name":"","range":"0° až 360°","cmc":"1,8´"}],"technique":"Pomiar za pomocą płytek kątowych","technique_en":"Measurement using angle gauges","technique_zh":"用角度块测量","technique_cs":"Měření pomocí úhlových měrek","techniques":["Pomiar za pomocą płytek kątowych"],"techniques_en":["Measurement using angle gauges"],"techniques_zh":["用角度块测量"],"techniques_cs":["Měření pomocí úhlových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0° do 360° CMC 1,8´\nPomiar za pomocą płytek kątowych","reference":"KPA-1.12","norm_bases":["KPA-1.12"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kątomierze Wzorcowanie – kąt płaski Pomiar za pomocą płytek kątowych od 0° do 360° CMC 1,8´ Úhloměry Kalibrace – rovinný úhel Měření pomocí úhlových měrek 0° až 360° CMC 1,8´ KPA-1.12 Katomierze Wzorcowanie – kat plaski Pomiar za pomoca plytek katowych od 0° do 360° CMC 1,8´ Uhlomery Kalibrace – rovinny uhel Mereni pomoci uhlovych merek 0° az 360° CMC 1,8´ KPA-1.12","search_en":"Angle gauges Calibration – plane angle Measurement using angle gauges 0° to 360° CMC 1,8´ KPA-1.12","search_zh":"角度尺 校准 – 平面角 用角度块测量 0° 至 360° CMC 1,8´ KPA-1.12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3aa300c5c957922bbc394f9c","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"3","test_object":"Poziomnice maszynowe – pomiar czułości","test_object_en":"Machinery levels – sensitivity measurement","test_object_zh":"机械水平仪 – 灵敏度测量","test_object_cs":"Strojní libely – měření citlivosti","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"Czułość nominalna do 0,02 mm/m","range":"od -1° do 1°","cmc":"5 µm/m"}],"parameters_en":[{"name":"Nominal sensitivity up to 0.02 mm/m","range":"-1° to 1°","cmc":"5 µm/m"}],"parameters_zh":[{"name":"标称灵敏度至 0,02 mm/m","range":"-1° 至 1°","cmc":"5 µm/m"}],"parameters_cs":[{"name":"Jmenovitá citlivost do 0,02 mm/m","range":"-1° až 1°","cmc":"5 µm/m"}],"technique":"Pomiar na generatorze małych kątów","technique_en":"Measurement on a small angle generator","technique_zh":"在小角度发生器上测量","technique_cs":"Měření na generátoru malých úhlů","techniques":["Pomiar na generatorze małych kątów"],"techniques_en":["Measurement on a small angle generator"],"techniques_zh":["在小角度发生器上测量"],"techniques_cs":["Měření na generátoru malých úhlů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nCzułość nominalna do 0,02 mm/m od -1° do 1° CMC 5 µm/m\nPomiar na generatorze małych kątów","reference":"KPA-1.11","norm_bases":["KPA-1.11"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Poziomnice maszynowe – pomiar czułości Wzorcowanie – kąt płaski Pomiar na generatorze małych kątów Czułość nominalna do 0,02 mm/m od -1° do 1° CMC 5 µm/m Strojní libely – měření citlivosti Kalibrace – rovinný úhel Měření na generátoru malých úhlů Jmenovitá citlivost do 0,02 mm/m -1° až 1° CMC 5 µm/m KPA-1.11 Poziomnice maszynowe – pomiar czulosci Wzorcowanie – kat plaski Pomiar na generatorze malych katow Czulosc nominalna do 0,02 mm/m od -1° do 1° CMC 5 µm/m Strojni libely – mereni citlivosti Kalibrace – rovinny uhel Mereni na generatoru malych uhlu Jmenovita citlivost do 0,02 mm/m -1° az 1° CMC 5 µm/m KPA-1.11","search_en":"Machinery levels – sensitivity measurement Calibration – plane angle Measurement on a small angle generator Nominal sensitivity up to 0.02 mm/m -1° to 1° CMC 5 µm/m KPA-1.11","search_zh":"机械水平仪 – 灵敏度测量 校准 – 平面角 在小角度发生器上测量 标称灵敏度至 0,02 mm/m -1° 至 1° CMC 5 µm/m KPA-1.11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c2f3f0c9ddcdf3f822b6b60","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne mechaniczne, cyfrowe","test_object_en":"Scales with non-automatic function, mechanical, digital","test_object_zh":"机械式、数字式非自动衡器","test_object_cs":"Váhy s neautomatickou činností mechanické, digitální","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"klasy E2","range":"od 0 kg do 2 kg","cmc":"1,6·10⁻⁶"},{"name":"klasy F1","range":"od 2 kg do 3 kg","cmc":"5·10⁻⁶"},{"name":"klasy F2","range":"od 3 kg do 45 kg","cmc":"1,6·10⁻⁵"},{"name":"klasy M1","range":"od 45 kg do 6000 kg","cmc":"5·10⁻⁵"},{"name":"klasy M1 z obciążeniem zastępczym","range":"od 6000 kg do 30000 kg","cmc":"1,6·10⁻⁴"}],"parameters_en":[{"name":"class E2","range":"0 kg to 2 kg","cmc":"1,6·10⁻⁶"},{"name":"class F1","range":"2 kg to 3 kg","cmc":"5·10⁻⁶"},{"name":"class F2","range":"3 kg to 45 kg","cmc":"1,6·10⁻⁵"},{"name":"class M1","range":"45 kg to 6000 kg","cmc":"5·10⁻⁵"},{"name":"class M1 with substitute load","range":"6000 kg to 30000 kg","cmc":"1,6·10⁻⁴"}],"parameters_zh":[{"name":"E2 级","range":"0 kg 至 2 kg","cmc":"1,6·10⁻⁶"},{"name":"F1 级","range":"2 kg 至 3 kg","cmc":"5·10⁻⁶"},{"name":"F2 级","range":"3 kg 至 45 kg","cmc":"1,6·10⁻⁵"},{"name":"M1 级","range":"45 kg 至 6000 kg","cmc":"5·10⁻⁵"},{"name":"M1 级，带替代载荷","range":"6000 kg 至 30000 kg","cmc":"1,6·10⁻⁴"}],"parameters_cs":[{"name":"třídy E2","range":"0 kg až 2 kg","cmc":"1,6·10⁻⁶"},{"name":"třídy F1","range":"2 kg až 3 kg","cmc":"5·10⁻⁶"},{"name":"třídy F2","range":"3 kg až 45 kg","cmc":"1,6·10⁻⁵"},{"name":"třídy M1","range":"45 kg až 6000 kg","cmc":"5·10⁻⁵"},{"name":"třídy M1 s náhradní zátěží","range":"6000 kg až 30000 kg","cmc":"1,6·10⁻⁴"}],"technique":"Obciążenie odważnikiem wzorcowym","technique_en":"Loading using a reference weight","technique_zh":"用标准砝码加载","technique_cs":"Zatížení etalonovým závažím","techniques":["Obciążenie odważnikiem wzorcowym"],"techniques_en":["Loading using a reference weight"],"techniques_zh":["用标准砝码加载"],"techniques_cs":["Zatížení etalonovým závažím"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nklasy E2 od 0 kg do 2 kg CMC 1,6·10⁻⁶\nklasy F1 od 2 kg do 3 kg CMC 5·10⁻⁶\nklasy F2 od 3 kg do 45 kg CMC 1,6·10⁻⁵\nklasy M1 od 45 kg do 6000 kg CMC 5·10⁻⁵\nklasy M1 z obciążeniem zastępczym od 6000 kg do 30000 kg CMC 1,6·10⁻⁴\nObciążenie odważnikiem wzorcowym","reference":"KPA-2.01","norm_bases":["KPA-2.01"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne mechaniczne, cyfrowe Wzorcowanie – masa Obciążenie odważnikiem wzorcowym klasy E2 od 0 kg do 2 kg CMC 1,6·10⁻⁶ klasy F1 od 2 kg do 3 kg CMC 5·10⁻⁶ klasy F2 od 3 kg do 45 kg CMC 1,6·10⁻⁵ klasy M1 od 45 kg do 6000 kg CMC 5·10⁻⁵ klasy M1 z obciążeniem zastępczym od 6000 kg do 30000 kg CMC 1,6·10⁻⁴ Váhy s neautomatickou činností mechanické, digitální Kalibrace – hmotnost Zatížení etalonovým závažím třídy E2 0 kg až 2 kg CMC 1,6·10⁻⁶ třídy F1 2 kg až 3 kg CMC 5·10⁻⁶ třídy F2 3 kg až 45 kg CMC 1,6·10⁻⁵ třídy M1 45 kg až 6000 kg CMC 5·10⁻⁵ třídy M1 s náhradní zátěží 6000 kg až 30000 kg CMC 1,6·10⁻⁴ KPA-2.01 Wagi nieautomatyczne mechaniczne, cyfrowe Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym klasy E2 od 0 kg do 2 kg CMC 1,6·10⁻⁶ klasy F1 od 2 kg do 3 kg CMC 5·10⁻⁶ klasy F2 od 3 kg do 45 kg CMC 1,6·10⁻⁵ klasy M1 od 45 kg do 6000 kg CMC 5·10⁻⁵ klasy M1 z obciazeniem zastepczym od 6000 kg do 30000 kg CMC 1,6·10⁻⁴ Vahy s neautomatickou cinnosti mechanicke, digitalni Kalibrace – hmotnost Zatizeni etalonovym zavazim tridy E2 0 kg az 2 kg CMC 1,6·10⁻⁶ tridy F1 2 kg az 3 kg CMC 5·10⁻⁶ tridy F2 3 kg az 45 kg CMC 1,6·10⁻⁵ tridy M1 45 kg az 6000 kg CMC 5·10⁻⁵ tridy M1 s nahradni zatezi 6000 kg az 30000 kg CMC 1,6·10⁻⁴ KPA-2.01","search_en":"Scales with non-automatic function, mechanical, digital Calibration – mass Loading using a reference weight class E2 0 kg to 2 kg CMC 1,6·10⁻⁶ class F1 2 kg to 3 kg CMC 5·10⁻⁶ class F2 3 kg to 45 kg CMC 1,6·10⁻⁵ class M1 45 kg to 6000 kg CMC 5·10⁻⁵ class M1 with substitute load 6000 kg to 30000 kg CMC 1,6·10⁻⁴ KPA-2.01","search_zh":"机械式、数字式非自动衡器 校准 – 质量 用标准砝码加载 E2 级 0 kg 至 2 kg CMC 1,6·10⁻⁶ F1 级 2 kg 至 3 kg CMC 5·10⁻⁶ F2 级 3 kg 至 45 kg CMC 1,6·10⁻⁵ M1 级 45 kg 至 6000 kg CMC 5·10⁻⁵ M1 级，带替代载荷 6000 kg 至 30000 kg CMC 1,6·10⁻⁴ KPA-2.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"677b40c659d5d0dd39702ff3","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"2","test_object":"Odważniki i inne ciała","test_object_en":"Weights and other objects","test_object_zh":"砝码及其他物体","test_object_cs":"Závaží a jiná tělesa","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 1 g do 500 g","cmc":"8,2 mg"},{"name":"","range":"od 0,5 kg do 1 kg","cmc":"8,6 mg"},{"name":"","range":"od 1 kg do 2 kg","cmc":"10 mg"},{"name":"","range":"od 2 kg do 5 kg","cmc":"16 mg"},{"name":"","range":"od 5 kg do 20 kg","cmc":"59 mg"}],"parameters_en":[{"name":"","range":"1 g to 500 g","cmc":"8,2 mg"},{"name":"","range":"0,5 kg to 1 kg","cmc":"8,6 mg"},{"name":"","range":"1 kg to 2 kg","cmc":"10 mg"},{"name":"","range":"2 kg to 5 kg","cmc":"16 mg"},{"name":"","range":"5 kg to 20 kg","cmc":"59 mg"}],"parameters_zh":[{"name":"","range":"1 g 至 500 g","cmc":"8,2 mg"},{"name":"","range":"0,5 kg 至 1 kg","cmc":"8,6 mg"},{"name":"","range":"1 kg 至 2 kg","cmc":"10 mg"},{"name":"","range":"2 kg 至 5 kg","cmc":"16 mg"},{"name":"","range":"5 kg 至 20 kg","cmc":"59 mg"}],"parameters_cs":[{"name":"","range":"1 g až 500 g","cmc":"8,2 mg"},{"name":"","range":"0,5 kg až 1 kg","cmc":"8,6 mg"},{"name":"","range":"1 kg až 2 kg","cmc":"10 mg"},{"name":"","range":"2 kg až 5 kg","cmc":"16 mg"},{"name":"","range":"5 kg až 20 kg","cmc":"59 mg"}],"technique":"Porównanie z odważnikiem wzorcowym","technique_en":"Comparison with a standard weight","technique_zh":"与标准砝码比较","technique_cs":"Porovnání s etalonovým závažím","techniques":["Porównanie z odważnikiem wzorcowym"],"techniques_en":["Comparison with a standard weight"],"techniques_zh":["与标准砝码比较"],"techniques_cs":["Porovnání s etalonovým závažím"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 1 g do 500 g CMC 8,2 mg\nod 0,5 kg do 1 kg CMC 8,6 mg\nod 1 kg do 2 kg CMC 10 mg\nod 2 kg do 5 kg CMC 16 mg\nod 5 kg do 20 kg CMC 59 mg\nPorównanie z odważnikiem wzorcowym","reference":"KPA-2.01","norm_bases":["KPA-2.01"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Odważniki i inne ciała Wzorcowanie – masa Porównanie z odważnikiem wzorcowym od 1 g do 500 g CMC 8,2 mg od 0,5 kg do 1 kg CMC 8,6 mg od 1 kg do 2 kg CMC 10 mg od 2 kg do 5 kg CMC 16 mg od 5 kg do 20 kg CMC 59 mg Závaží a jiná tělesa Kalibrace – hmotnost Porovnání s etalonovým závažím 1 g až 500 g CMC 8,2 mg 0,5 kg až 1 kg CMC 8,6 mg 1 kg až 2 kg CMC 10 mg 2 kg až 5 kg CMC 16 mg 5 kg až 20 kg CMC 59 mg KPA-2.01 Odwazniki i inne ciala Wzorcowanie – masa Porownanie z odwaznikiem wzorcowym od 1 g do 500 g CMC 8,2 mg od 0,5 kg do 1 kg CMC 8,6 mg od 1 kg do 2 kg CMC 10 mg od 2 kg do 5 kg CMC 16 mg od 5 kg do 20 kg CMC 59 mg Zavazi a jina telesa Kalibrace – hmotnost Porovnani s etalonovym zavazim 1 g az 500 g CMC 8,2 mg 0,5 kg az 1 kg CMC 8,6 mg 1 kg az 2 kg CMC 10 mg 2 kg az 5 kg CMC 16 mg 5 kg az 20 kg CMC 59 mg KPA-2.01","search_en":"Weights and other objects Calibration – mass Comparison with a standard weight 1 g to 500 g CMC 8,2 mg 0,5 kg to 1 kg CMC 8,6 mg 1 kg to 2 kg CMC 10 mg 2 kg to 5 kg CMC 16 mg 5 kg to 20 kg CMC 59 mg KPA-2.01","search_zh":"砝码及其他物体 校准 – 质量 与标准砝码比较 1 g 至 500 g CMC 8,2 mg 0,5 kg 至 1 kg CMC 8,6 mg 1 kg 至 2 kg CMC 10 mg 2 kg 至 5 kg CMC 16 mg 5 kg 至 20 kg CMC 59 mg KPA-2.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1e8120265b3fce381ef82e2e","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"2","test_object":"Odważniki i inne ciała","test_object_en":"Weights and other objects","test_object_zh":"砝码及其他物体","test_object_cs":"Závaží a jiná tělesa","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 1 g do 500 g","cmc":"8,2 mg"},{"name":"","range":"od 0,5 kg do 1 kg","cmc":"8,6 mg"},{"name":"","range":"od 1 kg do 2 kg","cmc":"10 mg"},{"name":"","range":"od 2 kg do 5 kg","cmc":"16 mg"},{"name":"","range":"od 5 kg do 20 kg","cmc":"59 mg"}],"parameters_en":[{"name":"","range":"1 g to 500 g","cmc":"8,2 mg"},{"name":"","range":"0,5 kg to 1 kg","cmc":"8,6 mg"},{"name":"","range":"1 kg to 2 kg","cmc":"10 mg"},{"name":"","range":"2 kg to 5 kg","cmc":"16 mg"},{"name":"","range":"5 kg to 20 kg","cmc":"59 mg"}],"parameters_zh":[{"name":"","range":"1 g 至 500 g","cmc":"8,2 mg"},{"name":"","range":"0,5 kg 至 1 kg","cmc":"8,6 mg"},{"name":"","range":"1 kg 至 2 kg","cmc":"10 mg"},{"name":"","range":"2 kg 至 5 kg","cmc":"16 mg"},{"name":"","range":"5 kg 至 20 kg","cmc":"59 mg"}],"parameters_cs":[{"name":"","range":"1 g až 500 g","cmc":"8,2 mg"},{"name":"","range":"0,5 kg až 1 kg","cmc":"8,6 mg"},{"name":"","range":"1 kg až 2 kg","cmc":"10 mg"},{"name":"","range":"2 kg až 5 kg","cmc":"16 mg"},{"name":"","range":"5 kg až 20 kg","cmc":"59 mg"}],"technique":"Porównanie z odważnikiem wzorcowym","technique_en":"Comparison with a standard weight","technique_zh":"与标准砝码比较","technique_cs":"Porovnání s etalonovým závažím","techniques":["Porównanie z odważnikiem wzorcowym"],"techniques_en":["Comparison with a standard weight"],"techniques_zh":["与标准砝码比较"],"techniques_cs":["Porovnání s etalonovým závažím"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 1 g do 500 g CMC 8,2 mg\nod 0,5 kg do 1 kg CMC 8,6 mg\nod 1 kg do 2 kg CMC 10 mg\nod 2 kg do 5 kg CMC 16 mg\nod 5 kg do 20 kg CMC 59 mg\nPorównanie z odważnikiem wzorcowym","reference":"KPA-2.01","norm_bases":["KPA-2.01"],"lab_section":"Pracownia Vlčí Habřina","lab_section_en":"Workplace Vlčí Habřina","lab_section_zh":"Vlčí Habřina 工作场所","lab_section_cs":"Pracoviště Vlčí Habřina","lab_address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Odważniki i inne ciała Wzorcowanie – masa Porównanie z odważnikiem wzorcowym od 1 g do 500 g CMC 8,2 mg od 0,5 kg do 1 kg CMC 8,6 mg od 1 kg do 2 kg CMC 10 mg od 2 kg do 5 kg CMC 16 mg od 5 kg do 20 kg CMC 59 mg Závaží a jiná tělesa Kalibrace – hmotnost Porovnání s etalonovým závažím 1 g až 500 g CMC 8,2 mg 0,5 kg až 1 kg CMC 8,6 mg 1 kg až 2 kg CMC 10 mg 2 kg až 5 kg CMC 16 mg 5 kg až 20 kg CMC 59 mg KPA-2.01 Odwazniki i inne ciala Wzorcowanie – masa Porownanie z odwaznikiem wzorcowym od 1 g do 500 g CMC 8,2 mg od 0,5 kg do 1 kg CMC 8,6 mg od 1 kg do 2 kg CMC 10 mg od 2 kg do 5 kg CMC 16 mg od 5 kg do 20 kg CMC 59 mg Zavazi a jina telesa Kalibrace – hmotnost Porovnani s etalonovym zavazim 1 g az 500 g CMC 8,2 mg 0,5 kg az 1 kg CMC 8,6 mg 1 kg az 2 kg CMC 10 mg 2 kg az 5 kg CMC 16 mg 5 kg az 20 kg CMC 59 mg KPA-2.01","search_en":"Weights and other objects Calibration – mass Comparison with a standard weight 1 g to 500 g CMC 8,2 mg 0,5 kg to 1 kg CMC 8,6 mg 1 kg to 2 kg CMC 10 mg 2 kg to 5 kg CMC 16 mg 5 kg to 20 kg CMC 59 mg KPA-2.01","search_zh":"砝码及其他物体 校准 – 质量 与标准砝码比较 1 g 至 500 g CMC 8,2 mg 0,5 kg 至 1 kg CMC 8,6 mg 1 kg 至 2 kg CMC 10 mg 2 kg 至 5 kg CMC 16 mg 5 kg 至 20 kg CMC 59 mg KPA-2.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0457b1ddab0986b2b86e8483","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Dokręcarki dynamometryczne","test_object_en":"Torque drivers","test_object_zh":"扭矩拧紧器","test_object_cs":"Momentové utahovačky","methodology":"Wzorcowanie – siła, moment siły","methodology_en":"Calibration – force, torque","methodology_zh":"校准 – 力、扭矩","methodology_cs":"Kalibrace – síla, moment síly","parameters":[{"name":"","range":"od 0,25 Nm do 50 Nm","cmc":"0,01"}],"parameters_en":[{"name":"","range":"0,25 Nm to 50 Nm","cmc":"0,01"}],"parameters_zh":[{"name":"","range":"0,25 Nm 至 50 Nm","cmc":"0,01"}],"parameters_cs":[{"name":"","range":"0,25 Nm až 50 Nm","cmc":"0,01"}],"technique":"Pomiar za pomocą przetwornika momentu siły","technique_en":"Measurement by a torque sensor","technique_zh":"用扭矩传感器测量","technique_cs":"Měření pomocí snímače momentu síly","techniques":["Pomiar za pomocą przetwornika momentu siły"],"techniques_en":["Measurement by a torque sensor"],"techniques_zh":["用扭矩传感器测量"],"techniques_cs":["Měření pomocí snímače momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, moment siły\nod 0,25 Nm do 50 Nm CMC 0,01\nPomiar za pomocą przetwornika momentu siły","reference":"KPA-5.01","norm_bases":["KPA-5.01"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, moment siły","regulatory_area_en":"CMC for the field of measured quantity: Force, torque","regulatory_area_zh":"被测量领域的CMC：力、扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Dokręcarki dynamometryczne Wzorcowanie – siła, moment siły Pomiar za pomocą przetwornika momentu siły od 0,25 Nm do 50 Nm CMC 0,01 Momentové utahovačky Kalibrace – síla, moment síly Měření pomocí snímače momentu síly 0,25 Nm až 50 Nm CMC 0,01 KPA-5.01 Dokrecarki dynamometryczne Wzorcowanie – sila, moment sily Pomiar za pomoca przetwornika momentu sily od 0,25 Nm do 50 Nm CMC 0,01 Momentove utahovacky Kalibrace – sila, moment sily Mereni pomoci snimace momentu sily 0,25 Nm az 50 Nm CMC 0,01 KPA-5.01","search_en":"Torque drivers Calibration – force, torque Measurement by a torque sensor 0,25 Nm to 50 Nm CMC 0,01 KPA-5.01","search_zh":"扭矩拧紧器 校准 – 力、扭矩 用扭矩传感器测量 0,25 Nm 至 50 Nm CMC 0,01 KPA-5.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"56d45cec8d96323d043d4ca1","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Klucze dynamometryczne, wkrętaki, przyrządy do pomiaru momentu siły","test_object_en":"Torque wrenches, screwdrivers, Moment of force meters","test_object_zh":"扭矩扳手、螺丝刀、扭矩测量仪","test_object_cs":"Momentové klíče, šroubováky, měřidla momentu síly","methodology":"Wzorcowanie – siła, moment siły","methodology_en":"Calibration – force, torque","methodology_zh":"校准 – 力、扭矩","methodology_cs":"Kalibrace – síla, moment síly","parameters":[{"name":"","range":"od 0,25 Nm do 0,5 Nm","cmc":"0,01"},{"name":"","range":"od 0,5 Nm do 200 Nm","cmc":"0,005"}],"parameters_en":[{"name":"","range":"0,25 Nm to 0,5 Nm","cmc":"0,01"},{"name":"","range":"0,5 Nm to 200 Nm","cmc":"0,005"}],"parameters_zh":[{"name":"","range":"0,25 Nm 至 0,5 Nm","cmc":"0,01"},{"name":"","range":"0,5 Nm 至 200 Nm","cmc":"0,005"}],"parameters_cs":[{"name":"","range":"0,25 Nm až 0,5 Nm","cmc":"0,01"},{"name":"","range":"0,5 Nm až 200 Nm","cmc":"0,005"}],"technique":"Pomiar za pomocą przetwornika momentu siły","technique_en":"Measurement by a torque sensor","technique_zh":"用扭矩传感器测量","technique_cs":"Měření pomocí snímače momentu síly","techniques":["Pomiar za pomocą przetwornika momentu siły"],"techniques_en":["Measurement by a torque sensor"],"techniques_zh":["用扭矩传感器测量"],"techniques_cs":["Měření pomocí snímače momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, moment siły\nZakres:\nod 0,25 Nm do 0,5 Nm CMC 0,01\nod 0,5 Nm do 200 Nm CMC 0,005\nPomiar za pomocą przetwornika momentu siły","reference":"KPA-5.01","norm_bases":["KPA-5.01"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, moment siły","regulatory_area_en":"CMC for the field of measured quantity: Force, torque","regulatory_area_zh":"被测量领域的CMC：力、扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Klucze dynamometryczne, wkrętaki, przyrządy do pomiaru momentu siły Wzorcowanie – siła, moment siły Pomiar za pomocą przetwornika momentu siły od 0,25 Nm do 0,5 Nm CMC 0,01 od 0,5 Nm do 200 Nm CMC 0,005 Momentové klíče, šroubováky, měřidla momentu síly Kalibrace – síla, moment síly Měření pomocí snímače momentu síly 0,25 Nm až 0,5 Nm CMC 0,01 0,5 Nm až 200 Nm CMC 0,005 KPA-5.01 Klucze dynamometryczne, wkretaki, przyrzady do pomiaru momentu sily Wzorcowanie – sila, moment sily Pomiar za pomoca przetwornika momentu sily od 0,25 Nm do 0,5 Nm CMC 0,01 od 0,5 Nm do 200 Nm CMC 0,005 Momentove klice, sroubovaky, meridla momentu sily Kalibrace – sila, moment sily Mereni pomoci snimace momentu sily 0,25 Nm az 0,5 Nm CMC 0,01 0,5 Nm az 200 Nm CMC 0,005 KPA-5.01","search_en":"Torque wrenches, screwdrivers, Moment of force meters Calibration – force, torque Measurement by a torque sensor 0,25 Nm to 0,5 Nm CMC 0,01 0,5 Nm to 200 Nm CMC 0,005 KPA-5.01","search_zh":"扭矩扳手、螺丝刀、扭矩测量仪 校准 – 力、扭矩 用扭矩传感器测量 0,25 Nm 至 0,5 Nm CMC 0,01 0,5 Nm 至 200 Nm CMC 0,005 KPA-5.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3e125cdfe2462f9b08deeb23","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Klucze dynamometryczne, wkrętaki, przyrządy do pomiaru momentu siły","test_object_en":"Torque wrenches, screwdrivers, Moment of force meters","test_object_zh":"扭矩扳手、螺丝刀、扭矩测量仪","test_object_cs":"Momentové klíče, šroubováky, měřidla momentu síly","methodology":"Wzorcowanie – siła, moment siły","methodology_en":"Calibration – force, torque","methodology_zh":"校准 – 力、扭矩","methodology_cs":"Kalibrace – síla, moment síly","parameters":[{"name":"","range":"od 200 Nm do 500 Nm","cmc":"0,005"}],"parameters_en":[{"name":"","range":"200 Nm to 500 Nm","cmc":"0,005"}],"parameters_zh":[{"name":"","range":"200 Nm 至 500 Nm","cmc":"0,005"}],"parameters_cs":[{"name":"","range":"200 Nm až 500 Nm","cmc":"0,005"}],"technique":"Pomiar za pomocą przetwornika momentu siły","technique_en":"Measurement by a torque sensor","technique_zh":"用扭矩传感器测量","technique_cs":"Měření pomocí snímače momentu síly","techniques":["Pomiar za pomocą przetwornika momentu siły"],"techniques_en":["Measurement by a torque sensor"],"techniques_zh":["用扭矩传感器测量"],"techniques_cs":["Měření pomocí snímače momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, moment siły\nod 200 Nm do 500 Nm CMC 0,005\nPomiar za pomocą przetwornika momentu siły","reference":"KPA-5.01","norm_bases":["KPA-5.01"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, moment siły","regulatory_area_en":"CMC for the field of measured quantity: Force, torque","regulatory_area_zh":"被测量领域的CMC：力、扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Klucze dynamometryczne, wkrętaki, przyrządy do pomiaru momentu siły Wzorcowanie – siła, moment siły Pomiar za pomocą przetwornika momentu siły od 200 Nm do 500 Nm CMC 0,005 Momentové klíče, šroubováky, měřidla momentu síly Kalibrace – síla, moment síly Měření pomocí snímače momentu síly 200 Nm až 500 Nm CMC 0,005 KPA-5.01 Klucze dynamometryczne, wkretaki, przyrzady do pomiaru momentu sily Wzorcowanie – sila, moment sily Pomiar za pomoca przetwornika momentu sily od 200 Nm do 500 Nm CMC 0,005 Momentove klice, sroubovaky, meridla momentu sily Kalibrace – sila, moment sily Mereni pomoci snimace momentu sily 200 Nm az 500 Nm CMC 0,005 KPA-5.01","search_en":"Torque wrenches, screwdrivers, Moment of force meters Calibration – force, torque Measurement by a torque sensor 200 Nm to 500 Nm CMC 0,005 KPA-5.01","search_zh":"扭矩扳手、螺丝刀、扭矩测量仪 校准 – 力、扭矩 用扭矩传感器测量 200 Nm 至 500 Nm CMC 0,005 KPA-5.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e24deffc88731b1b78de8e6a","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Klucze dynamometryczne, wkrętaki, przyrządy do pomiaru momentu siły","test_object_en":"Torque wrenches, screwdrivers, Moment of force meters","test_object_zh":"扭矩扳手、螺丝刀、扭矩测量仪","test_object_cs":"Momentové klíče, šroubováky, měřidla momentu síly","methodology":"Wzorcowanie – siła, moment siły","methodology_en":"Calibration – force, torque","methodology_zh":"校准 – 力、扭矩","methodology_cs":"Kalibrace – síla, moment síly","parameters":[{"name":"","range":"od 200 Nm do 500 Nm","cmc":"0,005"}],"parameters_en":[{"name":"","range":"200 Nm to 500 Nm","cmc":"0,005"}],"parameters_zh":[{"name":"","range":"200 Nm 至 500 Nm","cmc":"0,005"}],"parameters_cs":[{"name":"","range":"200 Nm až 500 Nm","cmc":"0,005"}],"technique":"Pomiar za pomocą przetwornika momentu siły","technique_en":"Measurement by a torque sensor","technique_zh":"用扭矩传感器测量","technique_cs":"Měření pomocí snímače momentu síly","techniques":["Pomiar za pomocą przetwornika momentu siły"],"techniques_en":["Measurement by a torque sensor"],"techniques_zh":["用扭矩传感器测量"],"techniques_cs":["Měření pomocí snímače momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, moment siły\nod 200 Nm do 500 Nm CMC 0,005\nPomiar za pomocą przetwornika momentu siły","reference":"KPA-5.01","norm_bases":["KPA-5.01"],"lab_section":"Pracownia Vlčí Habřina","lab_section_en":"Workplace Vlčí Habřina","lab_section_zh":"Vlčí Habřina 工作场所","lab_section_cs":"Pracoviště Vlčí Habřina","lab_address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, moment siły","regulatory_area_en":"CMC for the field of measured quantity: Force, torque","regulatory_area_zh":"被测量领域的CMC：力、扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Klucze dynamometryczne, wkrętaki, przyrządy do pomiaru momentu siły Wzorcowanie – siła, moment siły Pomiar za pomocą przetwornika momentu siły od 200 Nm do 500 Nm CMC 0,005 Momentové klíče, šroubováky, měřidla momentu síly Kalibrace – síla, moment síly Měření pomocí snímače momentu síly 200 Nm až 500 Nm CMC 0,005 KPA-5.01 Klucze dynamometryczne, wkretaki, przyrzady do pomiaru momentu sily Wzorcowanie – sila, moment sily Pomiar za pomoca przetwornika momentu sily od 200 Nm do 500 Nm CMC 0,005 Momentove klice, sroubovaky, meridla momentu sily Kalibrace – sila, moment sily Mereni pomoci snimace momentu sily 200 Nm az 500 Nm CMC 0,005 KPA-5.01","search_en":"Torque wrenches, screwdrivers, Moment of force meters Calibration – force, torque Measurement by a torque sensor 200 Nm to 500 Nm CMC 0,005 KPA-5.01","search_zh":"扭矩扳手、螺丝刀、扭矩测量仪 校准 – 力、扭矩 用扭矩传感器测量 200 Nm 至 500 Nm CMC 0,005 KPA-5.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b15b306a138e5d8b45e667f9","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Klucze dynamometryczne, wkrętaki, przyrządy do pomiaru momentu siły","test_object_en":"Torque wrenches, screwdrivers, Moment of force meters","test_object_zh":"扭矩扳手、螺丝刀、扭矩测量仪","test_object_cs":"Momentové klíče, šroubováky, měřidla momentu síly","methodology":"Wzorcowanie – siła, moment siły","methodology_en":"Calibration – force, torque","methodology_zh":"校准 – 力、扭矩","methodology_cs":"Kalibrace – síla, moment síly","parameters":[{"name":"","range":"od 500 Nm do 2000 Nm","cmc":"0,005"}],"parameters_en":[{"name":"","range":"500 Nm to 2000 Nm","cmc":"0,005"}],"parameters_zh":[{"name":"","range":"500 Nm 至 2000 Nm","cmc":"0,005"}],"parameters_cs":[{"name":"","range":"500 Nm až 2000 Nm","cmc":"0,005"}],"technique":"Pomiar za pomocą przetwornika momentu siły","technique_en":"Measurement by a torque sensor","technique_zh":"用扭矩传感器测量","technique_cs":"Měření pomocí snímače momentu síly","techniques":["Pomiar za pomocą przetwornika momentu siły"],"techniques_en":["Measurement by a torque sensor"],"techniques_zh":["用扭矩传感器测量"],"techniques_cs":["Měření pomocí snímače momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, moment siły\nod 500 Nm do 2000 Nm CMC 0,005\nPomiar za pomocą przetwornika momentu siły","reference":"KPA-5.01","norm_bases":["KPA-5.01"],"lab_section":"Pracownia Vlčí Habřina","lab_section_en":"Workplace Vlčí Habřina","lab_section_zh":"Vlčí Habřina 工作场所","lab_section_cs":"Pracoviště Vlčí Habřina","lab_address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, moment siły","regulatory_area_en":"CMC for the field of measured quantity: Force, torque","regulatory_area_zh":"被测量领域的CMC：力、扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Klucze dynamometryczne, wkrętaki, przyrządy do pomiaru momentu siły Wzorcowanie – siła, moment siły Pomiar za pomocą przetwornika momentu siły od 500 Nm do 2000 Nm CMC 0,005 Momentové klíče, šroubováky, měřidla momentu síly Kalibrace – síla, moment síly Měření pomocí snímače momentu síly 500 Nm až 2000 Nm CMC 0,005 KPA-5.01 Klucze dynamometryczne, wkretaki, przyrzady do pomiaru momentu sily Wzorcowanie – sila, moment sily Pomiar za pomoca przetwornika momentu sily od 500 Nm do 2000 Nm CMC 0,005 Momentove klice, sroubovaky, meridla momentu sily Kalibrace – sila, moment sily Mereni pomoci snimace momentu sily 500 Nm az 2000 Nm CMC 0,005 KPA-5.01","search_en":"Torque wrenches, screwdrivers, Moment of force meters Calibration – force, torque Measurement by a torque sensor 500 Nm to 2000 Nm CMC 0,005 KPA-5.01","search_zh":"扭矩扳手、螺丝刀、扭矩测量仪 校准 – 力、扭矩 用扭矩传感器测量 500 Nm 至 2000 Nm CMC 0,005 KPA-5.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ea10b1f482e86b024cfc4692","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"2","test_object":"Siłomierze, urządzenia siłomiercze","test_object_en":"Force meters, force measuring devices","test_object_zh":"测力计、测力装置","test_object_cs":"Siloměry, siloměrná zařízení","methodology":"Wzorcowanie – siła, moment siły","methodology_en":"Calibration – force, torque","methodology_zh":"校准 – 力、扭矩","methodology_cs":"Kalibrace – síla, moment síly","parameters":[{"name":"rozciąganie, ściskanie","range":"od 0 N do 500 N","cmc":"0,001"},{"name":"rozciąganie, ściskanie","range":"od 500 N do 10000 N","cmc":"0,003"},{"name":"rozciąganie, ściskanie","range":"od 10000 N do 100000 N","cmc":"0,005"}],"parameters_en":[{"name":"Tension, Compression","range":"0 N to 500 N","cmc":"0,001"},{"name":"Tension, Compression","range":"500 N to 10000 N","cmc":"0,003"},{"name":"Tension, Compression","range":"10000 N to 100000 N","cmc":"0,005"}],"parameters_zh":[{"name":"拉力、压力","range":"0 N 至 500 N","cmc":"0,001"},{"name":"拉力、压力","range":"500 N 至 10000 N","cmc":"0,003"},{"name":"拉力、压力","range":"10000 N 至 100000 N","cmc":"0,005"}],"parameters_cs":[{"name":"tah, tlak","range":"0 N až 500 N","cmc":"0,001"},{"name":"tah, tlak","range":"500 N až 10000 N","cmc":"0,003"},{"name":"tah, tlak","range":"10000 N až 100000 N","cmc":"0,005"}],"technique":"Pomiar za pomocą siłomierza wzorcowego","technique_en":"Measurement by a reference force meter","technique_zh":"用标准测力计测量","technique_cs":"Měření pomocí etalonového siloměru","techniques":["Pomiar za pomocą siłomierza wzorcowego"],"techniques_en":["Measurement by a reference force meter"],"techniques_zh":["用标准测力计测量"],"techniques_cs":["Měření pomocí etalonového siloměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, moment siły\nZakres:\nrozciąganie, ściskanie od 0 N do 500 N CMC 0,001\nrozciąganie, ściskanie od 500 N do 10000 N CMC 0,003\nrozciąganie, ściskanie od 10000 N do 100000 N CMC 0,005\nPomiar za pomocą siłomierza wzorcowego","reference":"KPA-5.02","norm_bases":["KPA-5.02"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, moment siły","regulatory_area_en":"CMC for the field of measured quantity: Force, torque","regulatory_area_zh":"被测量领域的CMC：力、扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Siłomierze, urządzenia siłomiercze Wzorcowanie – siła, moment siły Pomiar za pomocą siłomierza wzorcowego rozciąganie, ściskanie od 0 N do 500 N CMC 0,001 rozciąganie, ściskanie od 500 N do 10000 N CMC 0,003 rozciąganie, ściskanie od 10000 N do 100000 N CMC 0,005 Siloměry, siloměrná zařízení Kalibrace – síla, moment síly Měření pomocí etalonového siloměru tah, tlak 0 N až 500 N CMC 0,001 tah, tlak 500 N až 10000 N CMC 0,003 tah, tlak 10000 N až 100000 N CMC 0,005 KPA-5.02 Silomierze, urzadzenia silomiercze Wzorcowanie – sila, moment sily Pomiar za pomoca silomierza wzorcowego rozciaganie, sciskanie od 0 N do 500 N CMC 0,001 rozciaganie, sciskanie od 500 N do 10000 N CMC 0,003 rozciaganie, sciskanie od 10000 N do 100000 N CMC 0,005 Silomery, silomerna zarizeni Kalibrace – sila, moment sily Mereni pomoci etalonoveho silomeru tah, tlak 0 N az 500 N CMC 0,001 tah, tlak 500 N az 10000 N CMC 0,003 tah, tlak 10000 N az 100000 N CMC 0,005 KPA-5.02","search_en":"Force meters, force measuring devices Calibration – force, torque Measurement by a reference force meter Tension, Compression 0 N to 500 N CMC 0,001 Tension, Compression 500 N to 10000 N CMC 0,003 Tension, Compression 10000 N to 100000 N CMC 0,005 KPA-5.02","search_zh":"测力计、测力装置 校准 – 力、扭矩 用标准测力计测量 拉力、压力 0 N 至 500 N CMC 0,001 拉力、压力 500 N 至 10000 N CMC 0,003 拉力、压力 10000 N 至 100000 N CMC 0,005 KPA-5.02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b4c810c4617fba2110920266","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste, ciśnieniomierze cyfrowe, tory pomiarowe ciśnienia, przetworniki ciśnienia z wyjściem elektrycznym","test_object_en":"Deformation manometers, Digital manometers, Pressure measuring chains, Pressure transducers with electrical output","test_object_zh":"弹性压力表、数字压力表、压力测量链、带电输出的压力变送器","test_object_cs":"Deformační tlakoměry, číslicové tlakoměry, měřicí řetězce tlaku, převodníky tlaku s elektrickým výstupem","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"Podciśnienie/nadciśnienie, gazy","range":"od -95 kPa do 350 kPa","cmc":"0,26 kPa"},{"name":"Podciśnienie/nadciśnienie, gazy","range":"od 350 kPa do 1000 kPa","cmc":"0,58 kPa"},{"name":"Podciśnienie/nadciśnienie, gazy","range":"od 1 MPa do 3,5 MPa","cmc":"2,1 kPa"},{"name":"Podciśnienie/nadciśnienie, gazy","range":"od 3,5 MPa do 6 MPa","cmc":"6,9 kPa"},{"name":"Podciśnienie/nadciśnienie, ciecze","range":"od 0 MPa do 20 MPa","cmc":"35 kPa"},{"name":"Podciśnienie/nadciśnienie, ciecze","range":"od 20 MPa do 50 MPa","cmc":"87 kPa"}],"parameters_en":[{"name":"Underpressure / overpressure, Gases","range":"-95 kPa to 350 kPa","cmc":"0,26 kPa"},{"name":"Underpressure / overpressure, Gases","range":"350 kPa to 1000 kPa","cmc":"0,58 kPa"},{"name":"Underpressure / overpressure, Gases","range":"1 MPa to 3,5 MPa","cmc":"2,1 kPa"},{"name":"Underpressure / overpressure, Gases","range":"3,5 MPa to 6 MPa","cmc":"6,9 kPa"},{"name":"Underpressure / overpressure, Liquids","range":"0 MPa to 20 MPa","cmc":"35 kPa"},{"name":"Underpressure / overpressure, Liquids","range":"20 MPa to 50 MPa","cmc":"87 kPa"}],"parameters_zh":[{"name":"负压/正压，气体","range":"-95 kPa 至 350 kPa","cmc":"0,26 kPa"},{"name":"负压/正压，气体","range":"350 kPa 至 1000 kPa","cmc":"0,58 kPa"},{"name":"负压/正压，气体","range":"1 MPa 至 3,5 MPa","cmc":"2,1 kPa"},{"name":"负压/正压，气体","range":"3,5 MPa 至 6 MPa","cmc":"6,9 kPa"},{"name":"负压/正压，液体","range":"0 MPa 至 20 MPa","cmc":"35 kPa"},{"name":"负压/正压，液体","range":"20 MPa 至 50 MPa","cmc":"87 kPa"}],"parameters_cs":[{"name":"Podtlak/přetlak, plyny","range":"-95 kPa až 350 kPa","cmc":"0,26 kPa"},{"name":"Podtlak/přetlak, plyny","range":"350 kPa až 1000 kPa","cmc":"0,58 kPa"},{"name":"Podtlak/přetlak, plyny","range":"1 MPa až 3,5 MPa","cmc":"2,1 kPa"},{"name":"Podtlak/přetlak, plyny","range":"3,5 MPa až 6 MPa","cmc":"6,9 kPa"},{"name":"Podtlak/přetlak, kapaliny","range":"0 MPa až 20 MPa","cmc":"35 kPa"},{"name":"Podtlak/přetlak, kapaliny","range":"20 MPa až 50 MPa","cmc":"87 kPa"}],"technique":"Porównanie z ciśnieniomierzem wzorcowym","technique_en":"Comparison with a standard manometer","technique_zh":"与标准压力表比较","technique_cs":"Porovnání s etalonovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem wzorcowym"],"techniques_en":["Comparison with a standard manometer"],"techniques_zh":["与标准压力表比较"],"techniques_cs":["Porovnání s etalonovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nPodciśnienie/nadciśnienie, gazy od -95 kPa do 350 kPa CMC 0,26 kPa\nPodciśnienie/nadciśnienie, gazy od 350 kPa do 1000 kPa CMC 0,58 kPa\nPodciśnienie/nadciśnienie, gazy od 1 MPa do 3,5 MPa CMC 2,1 kPa\nPodciśnienie/nadciśnienie, gazy od 3,5 MPa do 6 MPa CMC 6,9 kPa\nPodciśnienie/nadciśnienie, ciecze od 0 MPa do 20 MPa CMC 35 kPa\nPodciśnienie/nadciśnienie, ciecze od 20 MPa do 50 MPa CMC 87 kPa\nPorównanie z ciśnieniomierzem wzorcowym","reference":"KPA-4.01, KPA-4.02","norm_bases":["KPA-4.01","KPA-4.02"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste, ciśnieniomierze cyfrowe, tory pomiarowe ciśnienia, przetworniki ciśnienia z wyjściem elektrycznym Wzorcowanie – ciśnienie Porównanie z ciśnieniomierzem wzorcowym Podciśnienie/nadciśnienie, gazy od -95 kPa do 350 kPa CMC 0,26 kPa Podciśnienie/nadciśnienie, gazy od 350 kPa do 1000 kPa CMC 0,58 kPa Podciśnienie/nadciśnienie, gazy od 1 MPa do 3,5 MPa CMC 2,1 kPa Podciśnienie/nadciśnienie, gazy od 3,5 MPa do 6 MPa CMC 6,9 kPa Podciśnienie/nadciśnienie, ciecze od 0 MPa do 20 MPa CMC 35 kPa Podciśnienie/nadciśnienie, ciecze od 20 MPa do 50 MPa CMC 87 kPa Deformační tlakoměry, číslicové tlakoměry, měřicí řetězce tlaku, převodníky tlaku s elektrickým výstupem Kalibrace – tlak Porovnání s etalonovým tlakoměrem Podtlak/přetlak, plyny -95 kPa až 350 kPa CMC 0,26 kPa Podtlak/přetlak, plyny 350 kPa až 1000 kPa CMC 0,58 kPa Podtlak/přetlak, plyny 1 MPa až 3,5 MPa CMC 2,1 kPa Podtlak/přetlak, plyny 3,5 MPa až 6 MPa CMC 6,9 kPa Podtlak/přetlak, kapaliny 0 MPa až 20 MPa CMC 35 kPa Podtlak/přetlak, kapaliny 20 MPa až 50 MPa CMC 87 kPa KPA-4.01, KPA-4.02 Cisnieniomierze sprezyste, cisnieniomierze cyfrowe, tory pomiarowe cisnienia, przetworniki cisnienia z wyjsciem elektrycznym Wzorcowanie – cisnienie Porownanie z cisnieniomierzem wzorcowym Podcisnienie/nadcisnienie, gazy od -95 kPa do 350 kPa CMC 0,26 kPa Podcisnienie/nadcisnienie, gazy od 350 kPa do 1000 kPa CMC 0,58 kPa Podcisnienie/nadcisnienie, gazy od 1 MPa do 3,5 MPa CMC 2,1 kPa Podcisnienie/nadcisnienie, gazy od 3,5 MPa do 6 MPa CMC 6,9 kPa Podcisnienie/nadcisnienie, ciecze od 0 MPa do 20 MPa CMC 35 kPa Podcisnienie/nadcisnienie, ciecze od 20 MPa do 50 MPa CMC 87 kPa Deformacni tlakomery, cislicove tlakomery, merici retezce tlaku, prevodniky tlaku s elektrickym vystupem Kalibrace – tlak Porovnani s etalonovym tlakomerem Podtlak/pretlak, plyny -95 kPa az 350 kPa CMC 0,26 kPa Podtlak/pretlak, plyny 350 kPa az 1000 kPa CMC 0,58 kPa Podtlak/pretlak, plyny 1 MPa az 3,5 MPa CMC 2,1 kPa Podtlak/pretlak, plyny 3,5 MPa az 6 MPa CMC 6,9 kPa Podtlak/pretlak, kapaliny 0 MPa az 20 MPa CMC 35 kPa Podtlak/pretlak, kapaliny 20 MPa az 50 MPa CMC 87 kPa KPA-4.01, KPA-4.02","search_en":"Deformation manometers, Digital manometers, Pressure measuring chains, Pressure transducers with electrical output Calibration – pressure Comparison with a standard manometer Underpressure / overpressure, Gases -95 kPa to 350 kPa CMC 0,26 kPa Underpressure / overpressure, Gases 350 kPa to 1000 kPa CMC 0,58 kPa Underpressure / overpressure, Gases 1 MPa to 3,5 MPa CMC 2,1 kPa Underpressure / overpressure, Gases 3,5 MPa to 6 MPa CMC 6,9 kPa Underpressure / overpressure, Liquids 0 MPa to 20 MPa CMC 35 kPa Underpressure / overpressure, Liquids 20 MPa to 50 MPa CMC 87 kPa KPA-4.01, KPA-4.02","search_zh":"弹性压力表、数字压力表、压力测量链、带电输出的压力变送器 校准 – 压力 与标准压力表比较 负压/正压，气体 -95 kPa 至 350 kPa CMC 0,26 kPa 负压/正压，气体 350 kPa 至 1000 kPa CMC 0,58 kPa 负压/正压，气体 1 MPa 至 3,5 MPa CMC 2,1 kPa 负压/正压，气体 3,5 MPa 至 6 MPa CMC 6,9 kPa 负压/正压，液体 0 MPa 至 20 MPa CMC 35 kPa 负压/正压，液体 20 MPa 至 50 MPa CMC 87 kPa KPA-4.01, KPA-4.02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a864a58848f380158bc018f1","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 200 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 200 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 200 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 200 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a standard thermometer in a liquid bath","technique_zh":"在液体槽中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalinové lázni","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a standard thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do 200 °C CMC 0,07 °C\n0 °C CMC 0,05 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej","reference":"KPA-3.01","norm_bases":["KPA-3.01"],"lab_section":"Pracownia Vlčí Habřina","lab_section_en":"Workplace Vlčí Habřina","lab_section_zh":"Vlčí Habřina 工作场所","lab_section_cs":"Pracoviště Vlčí Habřina","lab_address":"Vlčí Habřina 122, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej od -40 °C do 200 °C CMC 0,07 °C 0 °C CMC 0,05 °C Skleněné teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalinové lázni -40 °C až 200 °C CMC 0,07 °C 0 °C CMC 0,05 °C KPA-3.01 Termometry szklane Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej od -40 °C do 200 °C CMC 0,07 °C 0 °C CMC 0,05 °C Sklenene teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalinove lazni -40 °C az 200 °C CMC 0,07 °C 0 °C CMC 0,05 °C KPA-3.01","search_en":"Glass thermometers Calibration – temperature Comparison with a standard thermometer in a liquid bath -40 °C to 200 °C CMC 0,07 °C 0 °C CMC 0,05 °C KPA-3.01","search_zh":"玻璃温度计 校准 – 温度 在液体槽中与标准温度计比较 -40 °C 至 200 °C CMC 0,07 °C 0 °C CMC 0,05 °C KPA-3.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b5a4cd5f3f0ad6412e4a024f","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"2","test_object":"Termometry bezpośrednio wskazujące, regulatory temperatury","test_object_en":"Direct indicating thermometers, temperature controllers","test_object_zh":"直读式温度计、温度控制器","test_object_cs":"Přímoukazující teploměry, regulátory teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 200 °C","cmc":"0,08 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 200 °C","cmc":"0,08 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 200 °C","cmc":"0,08 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 200 °C","cmc":"0,08 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a standard thermometer in a liquid bath","technique_zh":"在液体槽中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalinové lázni","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a standard thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -40 °C do 200 °C CMC 0,08 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej","reference":"KPA-3.02","norm_bases":["KPA-3.02"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące, regulatory temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej od -40 °C do 200 °C CMC 0,08 °C Přímoukazující teploměry, regulátory teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalinové lázni -40 °C až 200 °C CMC 0,08 °C KPA-3.02 Termometry bezposrednio wskazujace, regulatory temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej od -40 °C do 200 °C CMC 0,08 °C Primoukazujici teplomery, regulatory teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalinove lazni -40 °C az 200 °C CMC 0,08 °C KPA-3.02","search_en":"Direct indicating thermometers, temperature controllers Calibration – temperature Comparison with a standard thermometer in a liquid bath -40 °C to 200 °C CMC 0,08 °C KPA-3.02","search_zh":"直读式温度计、温度控制器 校准 – 温度 在液体槽中与标准温度计比较 -40 °C 至 200 °C CMC 0,08 °C KPA-3.02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8bfd8918ee32e040624dadf9","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"2","test_object":"Termometry bezpośrednio wskazujące, regulatory temperatury","test_object_en":"Direct indicating thermometers, temperature controllers","test_object_zh":"直读式温度计、温度控制器","test_object_cs":"Přímoukazující teploměry, regulátory teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 200 °C do 400 °C","cmc":"0,44 °C"},{"name":"","range":"od 400 °C do 650 °C","cmc":"1,5 °C"},{"name":"","range":"od 650 °C do 900 °C","cmc":"1,8 °C"},{"name":"","range":"od 900 °C do 1200 °C","cmc":"2,4 °C"}],"parameters_en":[{"name":"","range":"200 °C to 400 °C","cmc":"0,44 °C"},{"name":"","range":"400 °C to 650 °C","cmc":"1,5 °C"},{"name":"","range":"650 °C to 900 °C","cmc":"1,8 °C"},{"name":"","range":"900 °C to 1200 °C","cmc":"2,4 °C"}],"parameters_zh":[{"name":"","range":"200 °C 至 400 °C","cmc":"0,44 °C"},{"name":"","range":"400 °C 至 650 °C","cmc":"1,5 °C"},{"name":"","range":"650 °C 至 900 °C","cmc":"1,8 °C"},{"name":"","range":"900 °C 至 1200 °C","cmc":"2,4 °C"}],"parameters_cs":[{"name":"","range":"200 °C až 400 °C","cmc":"0,44 °C"},{"name":"","range":"400 °C až 650 °C","cmc":"1,5 °C"},{"name":"","range":"650 °C až 900 °C","cmc":"1,8 °C"},{"name":"","range":"900 °C až 1200 °C","cmc":"2,4 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecu pionowym","technique_en":"Comparison with a standard thermometer in a vertical furnace","technique_zh":"在立式炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem ve vertikální peci","techniques":["Porównanie z termometrem wzorcowym w piecu pionowym"],"techniques_en":["Comparison with a standard thermometer in a vertical furnace"],"techniques_zh":["在立式炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem ve vertikální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 200 °C do 400 °C CMC 0,44 °C\nod 400 °C do 650 °C CMC 1,5 °C\nod 650 °C do 900 °C CMC 1,8 °C\nod 900 °C do 1200 °C CMC 2,4 °C\nPorównanie z termometrem wzorcowym w piecu pionowym","reference":"KPA-3.02","norm_bases":["KPA-3.02"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące, regulatory temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecu pionowym od 200 °C do 400 °C CMC 0,44 °C od 400 °C do 650 °C CMC 1,5 °C od 650 °C do 900 °C CMC 1,8 °C od 900 °C do 1200 °C CMC 2,4 °C Přímoukazující teploměry, regulátory teploty Kalibrace – teplota Porovnání s etalonovým teploměrem ve vertikální peci 200 °C až 400 °C CMC 0,44 °C 400 °C až 650 °C CMC 1,5 °C 650 °C až 900 °C CMC 1,8 °C 900 °C až 1200 °C CMC 2,4 °C KPA-3.02 Termometry bezposrednio wskazujace, regulatory temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecu pionowym od 200 °C do 400 °C CMC 0,44 °C od 400 °C do 650 °C CMC 1,5 °C od 650 °C do 900 °C CMC 1,8 °C od 900 °C do 1200 °C CMC 2,4 °C Primoukazujici teplomery, regulatory teploty Kalibrace – teplota Porovnani s etalonovym teplomerem ve vertikalni peci 200 °C az 400 °C CMC 0,44 °C 400 °C az 650 °C CMC 1,5 °C 650 °C az 900 °C CMC 1,8 °C 900 °C az 1200 °C CMC 2,4 °C KPA-3.02","search_en":"Direct indicating thermometers, temperature controllers Calibration – temperature Comparison with a standard thermometer in a vertical furnace 200 °C to 400 °C CMC 0,44 °C 400 °C to 650 °C CMC 1,5 °C 650 °C to 900 °C CMC 1,8 °C 900 °C to 1200 °C CMC 2,4 °C KPA-3.02","search_zh":"直读式温度计、温度控制器 校准 – 温度 在立式炉中与标准温度计比较 200 °C 至 400 °C CMC 0,44 °C 400 °C 至 650 °C CMC 1,5 °C 650 °C 至 900 °C CMC 1,8 °C 900 °C 至 1200 °C CMC 2,4 °C KPA-3.02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"db66f9aff33a8a3afdd8d6e1","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"3","test_object":"Termometry na podczerwień","test_object_en":"Infrared thermometers","test_object_zh":"红外温度计","test_object_cs":"Infrateploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 50 °C do 500 °C","cmc":"3,2 °C"}],"parameters_en":[{"name":"","range":"50 °C to 500 °C","cmc":"3,2 °C"}],"parameters_zh":[{"name":"","range":"50 °C 至 500 °C","cmc":"3,2 °C"}],"parameters_cs":[{"name":"","range":"50 °C až 500 °C","cmc":"3,2 °C"}],"technique":"Porównanie z wzorcem (ciałem czarnym)","technique_en":"Comparison with a standard (black body)","technique_zh":"与标准器（黑体）比较","technique_cs":"Porovnání s etalonem (černým tělesem)","techniques":["Porównanie z wzorcem (ciałem czarnym)"],"techniques_en":["Comparison with a standard (black body)"],"techniques_zh":["与标准器（黑体）比较"],"techniques_cs":["Porovnání s etalonem (černým tělesem)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 50 °C do 500 °C CMC 3,2 °C\nPorównanie z wzorcem (ciałem czarnym)","reference":"KPA-3.03","norm_bases":["KPA-3.03"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry na podczerwień Wzorcowanie – temperatura Porównanie z wzorcem (ciałem czarnym) od 50 °C do 500 °C CMC 3,2 °C Infrateploměry Kalibrace – teplota Porovnání s etalonem (černým tělesem) 50 °C až 500 °C CMC 3,2 °C KPA-3.03 Termometry na podczerwien Wzorcowanie – temperatura Porownanie z wzorcem (cialem czarnym) od 50 °C do 500 °C CMC 3,2 °C Infrateplomery Kalibrace – teplota Porovnani s etalonem (cernym telesem) 50 °C az 500 °C CMC 3,2 °C KPA-3.03","search_en":"Infrared thermometers Calibration – temperature Comparison with a standard (black body) 50 °C to 500 °C CMC 3,2 °C KPA-3.03","search_zh":"红外温度计 校准 – 温度 与标准器（黑体）比较 50 °C 至 500 °C CMC 3,2 °C KPA-3.03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"562d9469b0a78561c71659cb","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"4","test_object":"Termometry stykowe","test_object_en":"Contact thermometers","test_object_zh":"接触式温度计","test_object_cs":"Dotykové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 50 °C","cmc":"1,7 °C"},{"name":"","range":"od 50 °C do 100 °C","cmc":"1,9 °C"},{"name":"","range":"od 100 °C do 200 °C","cmc":"2,3 °C"},{"name":"","range":"od 200 °C do 400 °C","cmc":"2,6 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"3,5 °C"}],"parameters_en":[{"name":"","range":"0 °C to 50 °C","cmc":"1,7 °C"},{"name":"","range":"50 °C to 100 °C","cmc":"1,9 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"2,3 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"2,6 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"3,5 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 50 °C","cmc":"1,7 °C"},{"name":"","range":"50 °C 至 100 °C","cmc":"1,9 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"2,3 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"2,6 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"3,5 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 50 °C","cmc":"1,7 °C"},{"name":"","range":"50 °C až 100 °C","cmc":"1,9 °C"},{"name":"","range":"100 °C až 200 °C","cmc":"2,3 °C"},{"name":"","range":"200 °C až 400 °C","cmc":"2,6 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"3,5 °C"}],"technique":"Porównanie z termometrem wzorcowym","technique_en":"Comparison with a standard thermometer","technique_zh":"与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem","techniques":["Porównanie z termometrem wzorcowym"],"techniques_en":["Comparison with a standard thermometer"],"techniques_zh":["与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 0 °C do 50 °C CMC 1,7 °C\nod 50 °C do 100 °C CMC 1,9 °C\nod 100 °C do 200 °C CMC 2,3 °C\nod 200 °C do 400 °C CMC 2,6 °C\nod 400 °C do 600 °C CMC 3,5 °C\nPorównanie z termometrem wzorcowym","reference":"KPA-3.04","norm_bases":["KPA-3.04"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry stykowe Wzorcowanie – temperatura Porównanie z termometrem wzorcowym od 0 °C do 50 °C CMC 1,7 °C od 50 °C do 100 °C CMC 1,9 °C od 100 °C do 200 °C CMC 2,3 °C od 200 °C do 400 °C CMC 2,6 °C od 400 °C do 600 °C CMC 3,5 °C Dotykové teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem 0 °C až 50 °C CMC 1,7 °C 50 °C až 100 °C CMC 1,9 °C 100 °C až 200 °C CMC 2,3 °C 200 °C až 400 °C CMC 2,6 °C 400 °C až 600 °C CMC 3,5 °C KPA-3.04 Termometry stykowe Wzorcowanie – temperatura Porownanie z termometrem wzorcowym od 0 °C do 50 °C CMC 1,7 °C od 50 °C do 100 °C CMC 1,9 °C od 100 °C do 200 °C CMC 2,3 °C od 200 °C do 400 °C CMC 2,6 °C od 400 °C do 600 °C CMC 3,5 °C Dotykove teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem 0 °C az 50 °C CMC 1,7 °C 50 °C az 100 °C CMC 1,9 °C 100 °C az 200 °C CMC 2,3 °C 200 °C az 400 °C CMC 2,6 °C 400 °C az 600 °C CMC 3,5 °C KPA-3.04","search_en":"Contact thermometers Calibration – temperature Comparison with a standard thermometer 0 °C to 50 °C CMC 1,7 °C 50 °C to 100 °C CMC 1,9 °C 100 °C to 200 °C CMC 2,3 °C 200 °C to 400 °C CMC 2,6 °C 400 °C to 600 °C CMC 3,5 °C KPA-3.04","search_zh":"接触式温度计 校准 – 温度 与标准温度计比较 0 °C 至 50 °C CMC 1,7 °C 50 °C 至 100 °C CMC 1,9 °C 100 °C 至 200 °C CMC 2,3 °C 200 °C 至 400 °C CMC 2,6 °C 400 °C 至 600 °C CMC 3,5 °C KPA-3.04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0487e982e6801e093ebdfb3","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"5","test_object":"Czujniki termoelektryczne","test_object_en":"Thermocouple sensors","test_object_zh":"热电偶传感器","test_object_cs":"Termoelektrické snímače","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"K, J, N","range":"od -40 °C do 200 °C","cmc":"0,4 °C"}],"parameters_en":[{"name":"K, J, N","range":"-40 °C to 200 °C","cmc":"0,4 °C"}],"parameters_zh":[{"name":"K, J, N","range":"-40 °C 至 200 °C","cmc":"0,4 °C"}],"parameters_cs":[{"name":"K, J, N","range":"-40 °C až 200 °C","cmc":"0,4 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a standard thermometer in a liquid bath","technique_zh":"在液体槽中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalinové lázni","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a standard thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nK, J, N od -40 °C do 200 °C CMC 0,4 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej","reference":"KPA-3.05","norm_bases":["KPA-3.05"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki termoelektryczne Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej K, J, N od -40 °C do 200 °C CMC 0,4 °C Termoelektrické snímače Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalinové lázni K, J, N -40 °C až 200 °C CMC 0,4 °C KPA-3.05 Czujniki termoelektryczne Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej K, J, N od -40 °C do 200 °C CMC 0,4 °C Termoelektricke snimace Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalinove lazni K, J, N -40 °C az 200 °C CMC 0,4 °C KPA-3.05","search_en":"Thermocouple sensors Calibration – temperature Comparison with a standard thermometer in a liquid bath K, J, N -40 °C to 200 °C CMC 0,4 °C KPA-3.05","search_zh":"热电偶传感器 校准 – 温度 在液体槽中与标准温度计比较 K, J, N -40 °C 至 200 °C CMC 0,4 °C KPA-3.05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e793cc3a6d19e84cc5fc88ef","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"5","test_object":"Czujniki termoelektryczne","test_object_en":"Thermocouple sensors","test_object_zh":"热电偶传感器","test_object_cs":"Termoelektrické snímače","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"K, J, N","range":"od 200 °C do 400 °C","cmc":"0,6 °C"},{"name":"K, J, N","range":"od 400 °C do 650 °C","cmc":"1,6 °C"},{"name":"K, J, N","range":"od 650 °C do 900 °C","cmc":"2,3 °C"},{"name":"K, J, N","range":"od 900 °C do 1100 °C","cmc":"2,6 °C"}],"parameters_en":[{"name":"K, J, N","range":"200 °C to 400 °C","cmc":"0,6 °C"},{"name":"K, J, N","range":"400 °C to 650 °C","cmc":"1,6 °C"},{"name":"K, J, N","range":"650 °C to 900 °C","cmc":"2,3 °C"},{"name":"K, J, N","range":"900 °C to 1100 °C","cmc":"2,6 °C"}],"parameters_zh":[{"name":"K, J, N","range":"200 °C 至 400 °C","cmc":"0,6 °C"},{"name":"K, J, N","range":"400 °C 至 650 °C","cmc":"1,6 °C"},{"name":"K, J, N","range":"650 °C 至 900 °C","cmc":"2,3 °C"},{"name":"K, J, N","range":"900 °C 至 1100 °C","cmc":"2,6 °C"}],"parameters_cs":[{"name":"K, J, N","range":"200 °C až 400 °C","cmc":"0,6 °C"},{"name":"K, J, N","range":"400 °C až 650 °C","cmc":"1,6 °C"},{"name":"K, J, N","range":"650 °C až 900 °C","cmc":"2,3 °C"},{"name":"K, J, N","range":"900 °C až 1100 °C","cmc":"2,6 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecu pionowym","technique_en":"Comparison with a standard thermometer in a vertical furnace","technique_zh":"在立式炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem ve vertikální peci","techniques":["Porównanie z termometrem wzorcowym w piecu pionowym"],"techniques_en":["Comparison with a standard thermometer in a vertical furnace"],"techniques_zh":["在立式炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem ve vertikální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nK, J, N od 200 °C do 400 °C CMC 0,6 °C\nK, J, N od 400 °C do 650 °C CMC 1,6 °C\nK, J, N od 650 °C do 900 °C CMC 2,3 °C\nK, J, N od 900 °C do 1100 °C CMC 2,6 °C\nPorównanie z termometrem wzorcowym w piecu pionowym","reference":"KPA-3.05","norm_bases":["KPA-3.05"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki termoelektryczne Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecu pionowym K, J, N od 200 °C do 400 °C CMC 0,6 °C K, J, N od 400 °C do 650 °C CMC 1,6 °C K, J, N od 650 °C do 900 °C CMC 2,3 °C K, J, N od 900 °C do 1100 °C CMC 2,6 °C Termoelektrické snímače Kalibrace – teplota Porovnání s etalonovým teploměrem ve vertikální peci K, J, N 200 °C až 400 °C CMC 0,6 °C K, J, N 400 °C až 650 °C CMC 1,6 °C K, J, N 650 °C až 900 °C CMC 2,3 °C K, J, N 900 °C až 1100 °C CMC 2,6 °C KPA-3.05 Czujniki termoelektryczne Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecu pionowym K, J, N od 200 °C do 400 °C CMC 0,6 °C K, J, N od 400 °C do 650 °C CMC 1,6 °C K, J, N od 650 °C do 900 °C CMC 2,3 °C K, J, N od 900 °C do 1100 °C CMC 2,6 °C Termoelektricke snimace Kalibrace – teplota Porovnani s etalonovym teplomerem ve vertikalni peci K, J, N 200 °C az 400 °C CMC 0,6 °C K, J, N 400 °C az 650 °C CMC 1,6 °C K, J, N 650 °C az 900 °C CMC 2,3 °C K, J, N 900 °C az 1100 °C CMC 2,6 °C KPA-3.05","search_en":"Thermocouple sensors Calibration – temperature Comparison with a standard thermometer in a vertical furnace K, J, N 200 °C to 400 °C CMC 0,6 °C K, J, N 400 °C to 650 °C CMC 1,6 °C K, J, N 650 °C to 900 °C CMC 2,3 °C K, J, N 900 °C to 1100 °C CMC 2,6 °C KPA-3.05","search_zh":"热电偶传感器 校准 – 温度 在立式炉中与标准温度计比较 K, J, N 200 °C 至 400 °C CMC 0,6 °C K, J, N 400 °C 至 650 °C CMC 1,6 °C K, J, N 650 °C 至 900 °C CMC 2,3 °C K, J, N 900 °C 至 1100 °C CMC 2,6 °C KPA-3.05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"498e1d43b6bdb7476a4a6227","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"5","test_object":"Tor pomiarowy bez czujnika","test_object_en":"Measuring chain without a sensor","test_object_zh":"不带传感器的测量链","test_object_cs":"Měřící řetězec bez čidla","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"K, J, N","range":"od -100 °C do 1100 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"K, J, N","range":"-100 °C to 1100 °C","cmc":"0,3 °C"}],"parameters_zh":[{"name":"K, J, N","range":"-100 °C 至 1100 °C","cmc":"0,3 °C"}],"parameters_cs":[{"name":"K, J, N","range":"-100 °C až 1100 °C","cmc":"0,3 °C"}],"technique":"Pomiar bezpośredni na kalibratorze","technique_en":"Direct measurement on a calibrator","technique_zh":"在校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru","techniques":["Pomiar bezpośredni na kalibratorze"],"techniques_en":["Direct measurement on a calibrator"],"techniques_zh":["在校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nK, J, N od -100 °C do 1100 °C CMC 0,3 °C\nPomiar bezpośredni na kalibratorze","reference":"KPA-3.05","norm_bases":["KPA-3.05"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tor pomiarowy bez czujnika Wzorcowanie – temperatura Pomiar bezpośredni na kalibratorze K, J, N od -100 °C do 1100 °C CMC 0,3 °C Měřící řetězec bez čidla Kalibrace – teplota Přímé měření na kalibrátoru K, J, N -100 °C až 1100 °C CMC 0,3 °C KPA-3.05 Tor pomiarowy bez czujnika Wzorcowanie – temperatura Pomiar bezposredni na kalibratorze K, J, N od -100 °C do 1100 °C CMC 0,3 °C Merici retezec bez cidla Kalibrace – teplota Prime mereni na kalibratoru K, J, N -100 °C az 1100 °C CMC 0,3 °C KPA-3.05","search_en":"Measuring chain without a sensor Calibration – temperature Direct measurement on a calibrator K, J, N -100 °C to 1100 °C CMC 0,3 °C KPA-3.05","search_zh":"不带传感器的测量链 校准 – 温度 在校准器上直接测量 K, J, N -100 °C 至 1100 °C CMC 0,3 °C KPA-3.05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4dd15dccfa9736ffb80d5e5b","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"6","test_object":"Czujniki rezystancyjne","test_object_en":"Resistance sensors","test_object_zh":"电阻式传感器","test_object_cs":"Odporové snímače","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 200 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 200 °C","cmc":"0,2 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 200 °C","cmc":"0,2 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 200 °C","cmc":"0,2 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a standard thermometer in a liquid bath","technique_zh":"在液体槽中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalinové lázni","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a standard thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -40 °C do 200 °C CMC 0,2 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej","reference":"KPA-3.06","norm_bases":["KPA-3.06"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki rezystancyjne Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej od -40 °C do 200 °C CMC 0,2 °C Odporové snímače Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalinové lázni -40 °C až 200 °C CMC 0,2 °C KPA-3.06 Czujniki rezystancyjne Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej od -40 °C do 200 °C CMC 0,2 °C Odporove snimace Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalinove lazni -40 °C az 200 °C CMC 0,2 °C KPA-3.06","search_en":"Resistance sensors Calibration – temperature Comparison with a standard thermometer in a liquid bath -40 °C to 200 °C CMC 0,2 °C KPA-3.06","search_zh":"电阻式传感器 校准 – 温度 在液体槽中与标准温度计比较 -40 °C 至 200 °C CMC 0,2 °C KPA-3.06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4fb02ceed6efedefd84a5a79","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"6","test_object":"Czujniki rezystancyjne","test_object_en":"Resistance sensors","test_object_zh":"电阻式传感器","test_object_cs":"Odporové snímače","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 200 °C do 400 °C","cmc":"0,5 °C"}],"parameters_en":[{"name":"","range":"200 °C to 400 °C","cmc":"0,5 °C"}],"parameters_zh":[{"name":"","range":"200 °C 至 400 °C","cmc":"0,5 °C"}],"parameters_cs":[{"name":"","range":"200 °C až 400 °C","cmc":"0,5 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecu pionowym","technique_en":"Comparison with a standard thermometer in a vertical furnace","technique_zh":"在立式炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem ve vertikální peci","techniques":["Porównanie z termometrem wzorcowym w piecu pionowym"],"techniques_en":["Comparison with a standard thermometer in a vertical furnace"],"techniques_zh":["在立式炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem ve vertikální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 200 °C do 400 °C CMC 0,5 °C\nPorównanie z termometrem wzorcowym w piecu pionowym","reference":"KPA-3.06","norm_bases":["KPA-3.06"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki rezystancyjne Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecu pionowym od 200 °C do 400 °C CMC 0,5 °C Odporové snímače Kalibrace – teplota Porovnání s etalonovým teploměrem ve vertikální peci 200 °C až 400 °C CMC 0,5 °C KPA-3.06 Czujniki rezystancyjne Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecu pionowym od 200 °C do 400 °C CMC 0,5 °C Odporove snimace Kalibrace – teplota Porovnani s etalonovym teplomerem ve vertikalni peci 200 °C az 400 °C CMC 0,5 °C KPA-3.06","search_en":"Resistance sensors Calibration – temperature Comparison with a standard thermometer in a vertical furnace 200 °C to 400 °C CMC 0,5 °C KPA-3.06","search_zh":"电阻式传感器 校准 – 温度 在立式炉中与标准温度计比较 200 °C 至 400 °C CMC 0,5 °C KPA-3.06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1fa8f29d4d7232a3c49d0073","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"6","test_object":"Tor pomiarowy bez czujnika","test_object_en":"Measuring chain without a sensor","test_object_zh":"不带传感器的测量链","test_object_cs":"Měřící řetězec bez čidla","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -100 °C do 400 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C to 400 °C","cmc":"0,2 °C"}],"parameters_zh":[{"name":"","range":"-100 °C 至 400 °C","cmc":"0,2 °C"}],"parameters_cs":[{"name":"","range":"-100 °C až 400 °C","cmc":"0,2 °C"}],"technique":"Pomiar bezpośredni na kalibratorze","technique_en":"Direct measurement on a calibrator","technique_zh":"在校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru","techniques":["Pomiar bezpośredni na kalibratorze"],"techniques_en":["Direct measurement on a calibrator"],"techniques_zh":["在校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -100 °C do 400 °C CMC 0,2 °C\nPomiar bezpośredni na kalibratorze","reference":"KPA-3.06","norm_bases":["KPA-3.06"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tor pomiarowy bez czujnika Wzorcowanie – temperatura Pomiar bezpośredni na kalibratorze od -100 °C do 400 °C CMC 0,2 °C Měřící řetězec bez čidla Kalibrace – teplota Přímé měření na kalibrátoru -100 °C až 400 °C CMC 0,2 °C KPA-3.06 Tor pomiarowy bez czujnika Wzorcowanie – temperatura Pomiar bezposredni na kalibratorze od -100 °C do 400 °C CMC 0,2 °C Merici retezec bez cidla Kalibrace – teplota Prime mereni na kalibratoru -100 °C az 400 °C CMC 0,2 °C KPA-3.06","search_en":"Measuring chain without a sensor Calibration – temperature Direct measurement on a calibrator -100 °C to 400 °C CMC 0,2 °C KPA-3.06","search_zh":"不带传感器的测量链 校准 – 温度 在校准器上直接测量 -100 °C 至 400 °C CMC 0,2 °C KPA-3.06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7f6e026f7504aa80c2b69fb0","lab_id":"6ade8b30ff06824761708109","country":"CZ","accr_number":"2290","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru wilgotności powietrza","test_object_en":"Instruments for measuring air humidity","test_object_zh":"空气湿度测量仪器","test_object_cs":"Přístroje na měření vlhkosti vzduchu","methodology":"Wzorcowanie – wilgotność","methodology_en":"Calibration – humidity","methodology_zh":"校准 – 湿度","methodology_cs":"Kalibrace – vlhkost","parameters":[{"name":"Zakres temperatury (15 do 60) °C","range":"od 10 % RV do 90 % RV","cmc":"0,01 + 1,6 % RV"}],"parameters_en":[{"name":"Temperature range (15 to 60) °C","range":"10 % RV to 90 % RV","cmc":"0,01 + 1,6 % RV"}],"parameters_zh":[{"name":"温度范围 (15 至 60) °C","range":"10 % RV 至 90 % RV","cmc":"0,01 + 1,6 % RV"}],"parameters_cs":[{"name":"Rozsah teploty (15 až 60) °C","range":"10 % RV až 90 % RV","cmc":"0,01 + 1,6 % RV"}],"technique":"Porównanie z higrometrem wzorcowym","technique_en":"Comparison with a reference hygrometer","technique_zh":"与标准湿度计比较","technique_cs":"Porovnání s etalonovým vlhkoměrem","techniques":["Porównanie z higrometrem wzorcowym"],"techniques_en":["Comparison with a reference hygrometer"],"techniques_zh":["与标准湿度计比较"],"techniques_cs":["Porovnání s etalonovým vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność\nZakres temperatury (15 do 60) °C od 10 % RV do 90 % RV CMC 0,01 + 1,6 % RV\nPorównanie z higrometrem wzorcowym","reference":"KPA-6.01","norm_bases":["KPA-6.01"],"lab_section":"Pracownia Lázně Bohdaneč","lab_section_en":"Workplace Lázně Bohdaneč","lab_section_zh":"Lázně Bohdaneč 工作场所","lab_section_cs":"Pracoviště Lázně Bohdaneč","lab_address":"A. Dvořáka 719, 533 41 Lázně Bohdaneč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność","regulatory_area_en":"CMC for the field of measured quantity: Humidity","regulatory_area_zh":"被测量领域的CMC：湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru wilgotności powietrza Wzorcowanie – wilgotność Porównanie z higrometrem wzorcowym Zakres temperatury (15 do 60) °C od 10 % RV do 90 % RV CMC 0,01 + 1,6 % RV Přístroje na měření vlhkosti vzduchu Kalibrace – vlhkost Porovnání s etalonovým vlhkoměrem Rozsah teploty (15 až 60) °C 10 % RV až 90 % RV CMC 0,01 + 1,6 % RV KPA-6.01 Przyrzady do pomiaru wilgotnosci powietrza Wzorcowanie – wilgotnosc Porownanie z higrometrem wzorcowym Zakres temperatury (15 do 60) °C od 10 % RV do 90 % RV CMC 0,01 + 1,6 % RV Pristroje na mereni vlhkosti vzduchu Kalibrace – vlhkost Porovnani s etalonovym vlhkomerem Rozsah teploty (15 az 60) °C 10 % RV az 90 % RV CMC 0,01 + 1,6 % RV KPA-6.01","search_en":"Instruments for measuring air humidity Calibration – humidity Comparison with a reference hygrometer Temperature range (15 to 60) °C 10 % RV to 90 % RV CMC 0,01 + 1,6 % RV KPA-6.01","search_zh":"空气湿度测量仪器 校准 – 湿度 与标准湿度计比较 温度范围 (15 至 60) °C 10 % RV 至 90 % RV CMC 0,01 + 1,6 % RV KPA-6.01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}