🇨🇿 Český hydrometeorologický ústav PL
Metrology & calibration
Český hydrometeorologický ústav is a calibration laboratory accredited by ČIA under number 2287 (Praha 4, Czech Republic). Its accreditation scope covers 8 calibration items in the following areas: Metrology & calibration. Calibrated items include: Digital pressure gauges, Electronic and digital hygrometers, Electronic anemometers and transducers, Electronic thermometers. Most frequently used calibration principles: Comparison with a standard resistance thermometer in a liquid bath…, Direct comparison with a standard hygrometer, Measurement on a pressure calibrator.
At a glance
- Accreditation number: ČIA 2287
- Calibration items in scope: 8
- Types of calibrated items: 8
- Calibration principles used: 5
- City: Praha 4, Czech Republic
- Valid until: 23-01-2028
- Accreditation number
- 2287
- Accreditation body
- ČIA
- Address
- Generála Šišky 942, 143 00 Praha 4 - Kamýk
- City
- Praha 4, Czech Republic
- Division
- Meteorologiczne laboratorium wzorcujące
- Valid until
- 23-01-2028
What this laboratory calibrates (8)
- Digital pressure gauges — 1 calibration item
- Electronic and digital hygrometers — 1 calibration item
- Electronic anemometers and transducers — 1 calibration item
- Electronic thermometers — 1 calibration item
- Glass thermometers — 1 calibration item
- Humidity transducers — 1 calibration item
- Pressure transducers — 1 calibration item
- Resistance temperature sensors — 1 calibration item
Calibration principles (5)
- Comparison with a standard resistance thermometer in a liquid bath or climatic chamber — 2 calibration items
- Direct comparison with a standard hygrometer — 2 calibration items
- Measurement on a pressure calibrator — 2 calibration items
- Comparison with a standard anemometer in the open test section of a wind tunnel — 1 calibration item
- Comparison with a standard resistance thermometer in a liquid bath — 1 calibration item
Certificate information
- Certificate date
- 23.01.2023
Accreditation scope — calibration items (8)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Electronic anemometers and transducers | Calibration – air flow velocity 0,5 m·s⁻¹ to 4 m·s⁻¹ · CMC 0,13 m·s⁻¹ 4 m·s⁻¹ to 6 m·s⁻¹ · CMC 0,17 m·s⁻¹ 6 m·s⁻¹ to 10 m·s⁻¹ · CMC 0,22 m·s⁻¹ 10 m·s⁻¹ to 15 m·s⁻¹ · CMC 0,28 m·s⁻¹ 15 m·s⁻¹ to 30 m·s⁻¹ · CMC 0,30 m·s⁻¹ 30 m·s⁻¹ to 40 m·s⁻¹ · CMC 0,36 m·s⁻¹ 40 m·s⁻¹ to 50 m·s⁻¹ · CMC 0,38 m·s⁻¹ CMC for the field of measured quantity: Air flow velocity |
Comparison with a standard anemometer in the open test section of a wind tunnel | MKL – 02/17, MKL – 02/18 | |
| 2 | Pressure transducers | Calibration – pressure Absolute pressure, air — 500 hPa to 1100 hPa · CMC 0,002 % + 0,047 hPa CMC for the field of measured quantity: Pressure |
Measurement on a pressure calibrator | IP-MKL 2022/03 | |
| 3 | Digital pressure gauges | Calibration – pressure Absolute pressure, air — 500 hPa to 1100 hPa · CMC 0,047 hPa CMC for the field of measured quantity: Pressure |
Measurement on a pressure calibrator | IP-MKL 2022/03 | |
| 4 | Resistance temperature sensors | Calibration – temperature -40 °C to -30 °C · CMC 0,06 °C -30 °C to 90 °C · CMC 0,04 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance thermometer in a liquid bath or climatic chamber | MKL – 02/1 | |
| 5 | Glass thermometers | Calibration – temperature -40 °C to -30 °C · CMC 0,06 °C -30 °C to 0 °C · CMC 0,05 °C 0 °C to 30 °C · CMC 0,04 °C 30 °C to 90 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance thermometer in a liquid bath | MKL – 02/2 | |
| 6 | Electronic thermometers | Calibration – temperature -40 °C to 0 °C · CMC 0,06 °C 0 °C to 90 °C · CMC 0,04 °C CMC for the field of measured quantity: Temperature |
Comparison with a standard resistance thermometer in a liquid bath or climatic chamber | MKL – 02/3 | |
| 7 | Humidity transducers | Calibration – physico-chemical quantities – humidity 23 °C ± 5 °C — 10 % RH to 30 % RH · CMC 0,002 % + 1,3 % RH 23 °C ± 5 °C — 30 % RH to 80 % RH · CMC 0,002 % + 1,6 % RH 23 °C ± 5 °C — 80 % RH to 95 % RH · CMC 0,002 % + 2,3 % RH CMC for the field of measured quantity: Physico-chemical quantities – humidity |
Direct comparison with a standard hygrometer | MKL – 02/12 | |
| 8 | Electronic and digital hygrometers | Calibration – physico-chemical quantities – humidity 23 °C ± 5 °C — 10 % RH to 30 % RH · CMC 1,3 % RH 23 °C ± 5 °C — 30 % RH to 80 % RH · CMC 1,6 % RH 23 °C ± 5 °C — 80 % RH to 95 % RH · CMC 2,3 % RH CMC for the field of measured quantity: Physico-chemical quantities – humidity |
Direct comparison with a standard hygrometer | MKL – 02/13 | |
Reference standards (8)
IP-MKL 2022/03
MKL – 02/1
MKL – 02/12
MKL – 02/13
MKL – 02/17
MKL – 02/18
MKL – 02/2
MKL – 02/3