{"lab":{"_id":"6ade8b2fff06824761708107","accr_number":"2287","country":"CZ","accr_body":"ČIA","address":"Generála Šišky 942, 143 00 Praha 4 - Kamýk","categories":["metrology"],"city":"Praha 4","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.4471064,50.0073916]},"map_coord":[50.0073916,14.4471064],"map_geo":"cai-mapa","methods_count":8,"name":"Český hydrometeorologický ústav","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów pomiarowych w dziedzinach: temperatura, ciśnienie, wilgotność i prędkość przepływu powietrza.","search_text":"český hydrometeorologický ústav generála šišky 942, 143 00 praha 4 - kamýk 2287","source_page_url":"https://www.cai.cz/?subjekt=2287-cesky-hydrometeorologicky-ustav","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"23-01-2028","website":"www.chmi.cz","certificate_date":"23.01.2023","certificate_no":"17/2023","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów pomiarowych w dziedzinach: temperatura, ciśnienie, wilgotność i prędkość przepływu powietrza.","en":"Calibration of measuring instruments in the fields of temperature, pressure, humidity and air flow velocity.","zh":"温度、压力、湿度和气流速度领域测量仪器的校准。","cs":"Kalibrace měřidel v oboru teplota, tlak, vlhkost a rychlost proudění vzduchu."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Meteorologiczne laboratorium wzorcujące","lab_division_cs":"Meteorologická kalibrační laboratoř","lab_division_en":"Meteorological Calibration Laboratory","lab_division_zh":"气象校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"4a60c51b8dd1175863e980e29b0107da466e06ae8ee049dadd292c3667c2b450","source_pdf_url":"https://www.cai.cz/OA/pdf/P17_2023_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"d21b408f64f0a683697aa7a2","lab_id":"6ade8b2fff06824761708107","country":"CZ","accr_number":"2287","accr_body":"ČIA","row_label":"1","test_object":"Anemometry elektroniczne i przetworniki","test_object_en":"Electronic anemometers and transducers","test_object_zh":"电子风速计和变送器","test_object_cs":"Anemometry elektronické a převodníky","methodology":"Wzorcowanie – prędkość przepływu powietrza","methodology_en":"Calibration – air flow velocity","methodology_zh":"校准 – 气流速度","methodology_cs":"Kalibrace – rychlost proudění vzduchu","parameters":[{"name":"","range":"od 0,5 m·s⁻¹ do 4 m·s⁻¹","cmc":"0,13 m·s⁻¹"},{"name":"","range":"od 4 m·s⁻¹ do 6 m·s⁻¹","cmc":"0,17 m·s⁻¹"},{"name":"","range":"od 6 m·s⁻¹ do 10 m·s⁻¹","cmc":"0,22 m·s⁻¹"},{"name":"","range":"od 10 m·s⁻¹ do 15 m·s⁻¹","cmc":"0,28 m·s⁻¹"},{"name":"","range":"od 15 m·s⁻¹ do 30 m·s⁻¹","cmc":"0,30 m·s⁻¹"},{"name":"","range":"od 30 m·s⁻¹ do 40 m·s⁻¹","cmc":"0,36 m·s⁻¹"},{"name":"","range":"od 40 m·s⁻¹ do 50 m·s⁻¹","cmc":"0,38 m·s⁻¹"}],"parameters_en":[{"name":"","range":"0,5 m·s⁻¹ to 4 m·s⁻¹","cmc":"0,13 m·s⁻¹"},{"name":"","range":"4 m·s⁻¹ to 6 m·s⁻¹","cmc":"0,17 m·s⁻¹"},{"name":"","range":"6 m·s⁻¹ to 10 m·s⁻¹","cmc":"0,22 m·s⁻¹"},{"name":"","range":"10 m·s⁻¹ to 15 m·s⁻¹","cmc":"0,28 m·s⁻¹"},{"name":"","range":"15 m·s⁻¹ to 30 m·s⁻¹","cmc":"0,30 m·s⁻¹"},{"name":"","range":"30 m·s⁻¹ to 40 m·s⁻¹","cmc":"0,36 m·s⁻¹"},{"name":"","range":"40 m·s⁻¹ to 50 m·s⁻¹","cmc":"0,38 m·s⁻¹"}],"parameters_zh":[{"name":"","range":"0,5 m·s⁻¹ 至 4 m·s⁻¹","cmc":"0,13 m·s⁻¹"},{"name":"","range":"4 m·s⁻¹ 至 6 m·s⁻¹","cmc":"0,17 m·s⁻¹"},{"name":"","range":"6 m·s⁻¹ 至 10 m·s⁻¹","cmc":"0,22 m·s⁻¹"},{"name":"","range":"10 m·s⁻¹ 至 15 m·s⁻¹","cmc":"0,28 m·s⁻¹"},{"name":"","range":"15 m·s⁻¹ 至 30 m·s⁻¹","cmc":"0,30 m·s⁻¹"},{"name":"","range":"30 m·s⁻¹ 至 40 m·s⁻¹","cmc":"0,36 m·s⁻¹"},{"name":"","range":"40 m·s⁻¹ 至 50 m·s⁻¹","cmc":"0,38 m·s⁻¹"}],"parameters_cs":[{"name":"","range":"0,5 m·s⁻¹ až 4 m·s⁻¹","cmc":"0,13 m·s⁻¹"},{"name":"","range":"4 m·s⁻¹ až 6 m·s⁻¹","cmc":"0,17 m·s⁻¹"},{"name":"","range":"6 m·s⁻¹ až 10 m·s⁻¹","cmc":"0,22 m·s⁻¹"},{"name":"","range":"10 m·s⁻¹ až 15 m·s⁻¹","cmc":"0,28 m·s⁻¹"},{"name":"","range":"15 m·s⁻¹ až 30 m·s⁻¹","cmc":"0,30 m·s⁻¹"},{"name":"","range":"30 m·s⁻¹ až 40 m·s⁻¹","cmc":"0,36 m·s⁻¹"},{"name":"","range":"40 m·s⁻¹ až 50 m·s⁻¹","cmc":"0,38 m·s⁻¹"}],"technique":"Porównanie z anemometrem wzorcowym w otwartej przestrzeni pomiarowej tunelu aerodynamicznego","technique_en":"Comparison with a standard anemometer in the open test section of a wind tunnel","technique_zh":"在风洞开放式测量段中与标准风速计比较","technique_cs":"Porovnání s etalonovým anemometrem v otevřeném měřícím prostoru aerodynamického tunelu","techniques":["Porównanie z anemometrem wzorcowym w otwartej przestrzeni pomiarowej tunelu aerodynamicznego"],"techniques_en":["Comparison with a standard anemometer in the open test section of a wind tunnel"],"techniques_zh":["在风洞开放式测量段中与标准风速计比较"],"techniques_cs":["Porovnání s etalonovým anemometrem v otevřeném měřícím prostoru aerodynamického tunelu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – prędkość przepływu powietrza\nZakres:\nod 0,5 m·s⁻¹ do 4 m·s⁻¹ CMC 0,13 m·s⁻¹\nod 4 m·s⁻¹ do 6 m·s⁻¹ CMC 0,17 m·s⁻¹\nod 6 m·s⁻¹ do 10 m·s⁻¹ CMC 0,22 m·s⁻¹\nod 10 m·s⁻¹ do 15 m·s⁻¹ CMC 0,28 m·s⁻¹\nod 15 m·s⁻¹ do 30 m·s⁻¹ CMC 0,30 m·s⁻¹\nod 30 m·s⁻¹ do 40 m·s⁻¹ CMC 0,36 m·s⁻¹\nod 40 m·s⁻¹ do 50 m·s⁻¹ CMC 0,38 m·s⁻¹\nPorównanie z anemometrem wzorcowym w otwartej przestrzeni pomiarowej tunelu aerodynamicznego","reference":"MKL – 02/17, MKL – 02/18","norm_bases":["MKL – 02/17","MKL – 02/18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: prędkość przepływu powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air flow velocity","regulatory_area_zh":"被测量领域的CMC：气流速度","regulatory_area_cs":"CMC pro obor měřené veličiny: Rychlost proudění vzduchu","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Anemometry elektroniczne i przetworniki Wzorcowanie – prędkość przepływu powietrza Porównanie z anemometrem wzorcowym w otwartej przestrzeni pomiarowej tunelu aerodynamicznego od 0,5 m·s⁻¹ do 4 m·s⁻¹ CMC 0,13 m·s⁻¹ od 4 m·s⁻¹ do 6 m·s⁻¹ CMC 0,17 m·s⁻¹ od 6 m·s⁻¹ do 10 m·s⁻¹ CMC 0,22 m·s⁻¹ od 10 m·s⁻¹ do 15 m·s⁻¹ CMC 0,28 m·s⁻¹ od 15 m·s⁻¹ do 30 m·s⁻¹ CMC 0,30 m·s⁻¹ od 30 m·s⁻¹ do 40 m·s⁻¹ CMC 0,36 m·s⁻¹ od 40 m·s⁻¹ do 50 m·s⁻¹ CMC 0,38 m·s⁻¹ Anemometry elektronické a převodníky Kalibrace – rychlost proudění vzduchu Porovnání s etalonovým anemometrem v otevřeném měřícím prostoru aerodynamického tunelu 0,5 m·s⁻¹ až 4 m·s⁻¹ CMC 0,13 m·s⁻¹ 4 m·s⁻¹ až 6 m·s⁻¹ CMC 0,17 m·s⁻¹ 6 m·s⁻¹ až 10 m·s⁻¹ CMC 0,22 m·s⁻¹ 10 m·s⁻¹ až 15 m·s⁻¹ CMC 0,28 m·s⁻¹ 15 m·s⁻¹ až 30 m·s⁻¹ CMC 0,30 m·s⁻¹ 30 m·s⁻¹ až 40 m·s⁻¹ CMC 0,36 m·s⁻¹ 40 m·s⁻¹ až 50 m·s⁻¹ CMC 0,38 m·s⁻¹ MKL – 02/17, MKL – 02/18 Anemometry elektroniczne i przetworniki Wzorcowanie – predkosc przeplywu powietrza Porownanie z anemometrem wzorcowym w otwartej przestrzeni pomiarowej tunelu aerodynamicznego od 0,5 m·s⁻¹ do 4 m·s⁻¹ CMC 0,13 m·s⁻¹ od 4 m·s⁻¹ do 6 m·s⁻¹ CMC 0,17 m·s⁻¹ od 6 m·s⁻¹ do 10 m·s⁻¹ CMC 0,22 m·s⁻¹ od 10 m·s⁻¹ do 15 m·s⁻¹ CMC 0,28 m·s⁻¹ od 15 m·s⁻¹ do 30 m·s⁻¹ CMC 0,30 m·s⁻¹ od 30 m·s⁻¹ do 40 m·s⁻¹ CMC 0,36 m·s⁻¹ od 40 m·s⁻¹ do 50 m·s⁻¹ CMC 0,38 m·s⁻¹ Anemometry elektronicke a prevodniky Kalibrace – rychlost proudeni vzduchu Porovnani s etalonovym anemometrem v otevrenem mericim prostoru aerodynamickeho tunelu 0,5 m·s⁻¹ az 4 m·s⁻¹ CMC 0,13 m·s⁻¹ 4 m·s⁻¹ az 6 m·s⁻¹ CMC 0,17 m·s⁻¹ 6 m·s⁻¹ az 10 m·s⁻¹ CMC 0,22 m·s⁻¹ 10 m·s⁻¹ az 15 m·s⁻¹ CMC 0,28 m·s⁻¹ 15 m·s⁻¹ az 30 m·s⁻¹ CMC 0,30 m·s⁻¹ 30 m·s⁻¹ az 40 m·s⁻¹ CMC 0,36 m·s⁻¹ 40 m·s⁻¹ az 50 m·s⁻¹ CMC 0,38 m·s⁻¹ MKL – 02/17, MKL – 02/18","search_en":"Electronic anemometers and transducers Calibration – air flow velocity Comparison with a standard anemometer in the open test section of a wind tunnel 0,5 m·s⁻¹ to 4 m·s⁻¹ CMC 0,13 m·s⁻¹ 4 m·s⁻¹ to 6 m·s⁻¹ CMC 0,17 m·s⁻¹ 6 m·s⁻¹ to 10 m·s⁻¹ CMC 0,22 m·s⁻¹ 10 m·s⁻¹ to 15 m·s⁻¹ CMC 0,28 m·s⁻¹ 15 m·s⁻¹ to 30 m·s⁻¹ CMC 0,30 m·s⁻¹ 30 m·s⁻¹ to 40 m·s⁻¹ CMC 0,36 m·s⁻¹ 40 m·s⁻¹ to 50 m·s⁻¹ CMC 0,38 m·s⁻¹ MKL – 02/17, MKL – 02/18","search_zh":"电子风速计和变送器 校准 – 气流速度 在风洞开放式测量段中与标准风速计比较 0,5 m·s⁻¹ 至 4 m·s⁻¹ CMC 0,13 m·s⁻¹ 4 m·s⁻¹ 至 6 m·s⁻¹ CMC 0,17 m·s⁻¹ 6 m·s⁻¹ 至 10 m·s⁻¹ CMC 0,22 m·s⁻¹ 10 m·s⁻¹ 至 15 m·s⁻¹ CMC 0,28 m·s⁻¹ 15 m·s⁻¹ 至 30 m·s⁻¹ CMC 0,30 m·s⁻¹ 30 m·s⁻¹ 至 40 m·s⁻¹ CMC 0,36 m·s⁻¹ 40 m·s⁻¹ 至 50 m·s⁻¹ CMC 0,38 m·s⁻¹ MKL – 02/17, MKL – 02/18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a17736597030978d0337023d","lab_id":"6ade8b2fff06824761708107","country":"CZ","accr_number":"2287","accr_body":"ČIA","row_label":"1","test_object":"Przetworniki ciśnienia","test_object_en":"Pressure transducers","test_object_zh":"压力变送器","test_object_cs":"Převodníky tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"Ciśnienie bezwzględne, powietrze","range":"od 500 hPa do 1100 hPa","cmc":"0,002 % + 0,047 hPa"}],"parameters_en":[{"name":"Absolute pressure, air","range":"500 hPa to 1100 hPa","cmc":"0,002 % + 0,047 hPa"}],"parameters_zh":[{"name":"绝对压力，空气","range":"500 hPa 至 1100 hPa","cmc":"0,002 % + 0,047 hPa"}],"parameters_cs":[{"name":"Absolutní tlak, vzduch","range":"500 hPa až 1100 hPa","cmc":"0,002 % + 0,047 hPa"}],"technique":"Pomiar na kalibratorze ciśnienia","technique_en":"Measurement on a pressure calibrator","technique_zh":"在压力校准器上测量","technique_cs":"Měření na kalibrátoru tlaku","techniques":["Pomiar na kalibratorze ciśnienia"],"techniques_en":["Measurement on a pressure calibrator"],"techniques_zh":["在压力校准器上测量"],"techniques_cs":["Měření na kalibrátoru tlaku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nCiśnienie bezwzględne, powietrze od 500 hPa do 1100 hPa CMC 0,002 % + 0,047 hPa\nPomiar na kalibratorze ciśnienia","reference":"IP-MKL 2022/03","norm_bases":["IP-MKL 2022/03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przetworniki ciśnienia Wzorcowanie – ciśnienie Pomiar na kalibratorze ciśnienia Ciśnienie bezwzględne, powietrze od 500 hPa do 1100 hPa CMC 0,002 % + 0,047 hPa Převodníky tlaku Kalibrace – tlak Měření na kalibrátoru tlaku Absolutní tlak, vzduch 500 hPa až 1100 hPa CMC 0,002 % + 0,047 hPa IP-MKL 2022/03 Przetworniki cisnienia Wzorcowanie – cisnienie Pomiar na kalibratorze cisnienia Cisnienie bezwzgledne, powietrze od 500 hPa do 1100 hPa CMC 0,002 % + 0,047 hPa Prevodniky tlaku Kalibrace – tlak Mereni na kalibratoru tlaku Absolutni tlak, vzduch 500 hPa az 1100 hPa CMC 0,002 % + 0,047 hPa IP-MKL 2022/03","search_en":"Pressure transducers Calibration – pressure Measurement on a pressure calibrator Absolute pressure, air 500 hPa to 1100 hPa CMC 0,002 % + 0,047 hPa IP-MKL 2022/03","search_zh":"压力变送器 校准 – 压力 在压力校准器上测量 绝对压力，空气 500 hPa 至 1100 hPa CMC 0,002 % + 0,047 hPa IP-MKL 2022/03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8d2bc947a43844288bd8a204","lab_id":"6ade8b2fff06824761708107","country":"CZ","accr_number":"2287","accr_body":"ČIA","row_label":"2","test_object":"Ciśnieniomierze cyfrowe","test_object_en":"Digital pressure gauges","test_object_zh":"数字压力计","test_object_cs":"Digitální tlakoměry","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"Ciśnienie bezwzględne, powietrze","range":"od 500 hPa do 1100 hPa","cmc":"0,047 hPa"}],"parameters_en":[{"name":"Absolute pressure, air","range":"500 hPa to 1100 hPa","cmc":"0,047 hPa"}],"parameters_zh":[{"name":"绝对压力，空气","range":"500 hPa 至 1100 hPa","cmc":"0,047 hPa"}],"parameters_cs":[{"name":"Absolutní tlak, vzduch","range":"500 hPa až 1100 hPa","cmc":"0,047 hPa"}],"technique":"Pomiar na kalibratorze ciśnienia","technique_en":"Measurement on a pressure calibrator","technique_zh":"在压力校准器上测量","technique_cs":"Měření na kalibrátoru tlaku","techniques":["Pomiar na kalibratorze ciśnienia"],"techniques_en":["Measurement on a pressure calibrator"],"techniques_zh":["在压力校准器上测量"],"techniques_cs":["Měření na kalibrátoru tlaku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nCiśnienie bezwzględne, powietrze od 500 hPa do 1100 hPa CMC 0,047 hPa\nPomiar na kalibratorze ciśnienia","reference":"IP-MKL 2022/03","norm_bases":["IP-MKL 2022/03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze cyfrowe Wzorcowanie – ciśnienie Pomiar na kalibratorze ciśnienia Ciśnienie bezwzględne, powietrze od 500 hPa do 1100 hPa CMC 0,047 hPa Digitální tlakoměry Kalibrace – tlak Měření na kalibrátoru tlaku Absolutní tlak, vzduch 500 hPa až 1100 hPa CMC 0,047 hPa IP-MKL 2022/03 Cisnieniomierze cyfrowe Wzorcowanie – cisnienie Pomiar na kalibratorze cisnienia Cisnienie bezwzgledne, powietrze od 500 hPa do 1100 hPa CMC 0,047 hPa Digitalni tlakomery Kalibrace – tlak Mereni na kalibratoru tlaku Absolutni tlak, vzduch 500 hPa az 1100 hPa CMC 0,047 hPa IP-MKL 2022/03","search_en":"Digital pressure gauges Calibration – pressure Measurement on a pressure calibrator Absolute pressure, air 500 hPa to 1100 hPa CMC 0,047 hPa IP-MKL 2022/03","search_zh":"数字压力计 校准 – 压力 在压力校准器上测量 绝对压力，空气 500 hPa 至 1100 hPa CMC 0,047 hPa IP-MKL 2022/03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e07f7c8ba0160f90fd0d6286","lab_id":"6ade8b2fff06824761708107","country":"CZ","accr_number":"2287","accr_body":"ČIA","row_label":"1","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻式温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do -30 °C","cmc":"0,06 °C"},{"name":"","range":"od -30 °C do 90 °C","cmc":"0,04 °C"}],"parameters_en":[{"name":"","range":"-40 °C to -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C to 90 °C","cmc":"0,04 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C 至 90 °C","cmc":"0,04 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C až 90 °C","cmc":"0,04 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej lub komorze klimatycznej","technique_en":"Comparison with a standard resistance thermometer in a liquid bath or climatic chamber","technique_zh":"在液体槽或气候箱中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni nebo klimatické komoře","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej lub komorze klimatycznej"],"techniques_en":["Comparison with a standard resistance thermometer in a liquid bath or climatic chamber"],"techniques_zh":["在液体槽或气候箱中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni nebo klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do -30 °C CMC 0,06 °C\nod -30 °C do 90 °C CMC 0,04 °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej lub komorze klimatycznej","reference":"MKL – 02/1","norm_bases":["MKL – 02/1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej lub komorze klimatycznej od -40 °C do -30 °C CMC 0,06 °C od -30 °C do 90 °C CMC 0,04 °C Odporové snímače teploty Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni nebo klimatické komoře -40 °C až -30 °C CMC 0,06 °C -30 °C až 90 °C CMC 0,04 °C MKL – 02/1 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej lub komorze klimatycznej od -40 °C do -30 °C CMC 0,06 °C od -30 °C do 90 °C CMC 0,04 °C Odporove snimace teploty Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni nebo klimaticke komore -40 °C az -30 °C CMC 0,06 °C -30 °C az 90 °C CMC 0,04 °C MKL – 02/1","search_en":"Resistance temperature sensors Calibration – temperature Comparison with a standard resistance thermometer in a liquid bath or climatic chamber -40 °C to -30 °C CMC 0,06 °C -30 °C to 90 °C CMC 0,04 °C MKL – 02/1","search_zh":"电阻式温度传感器 校准 – 温度 在液体槽或气候箱中与标准电阻温度计比较 -40 °C 至 -30 °C CMC 0,06 °C -30 °C 至 90 °C CMC 0,04 °C MKL – 02/1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7721c3fe5fc03cc627fa9233","lab_id":"6ade8b2fff06824761708107","country":"CZ","accr_number":"2287","accr_body":"ČIA","row_label":"2","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do -30 °C","cmc":"0,06 °C"},{"name":"","range":"od -30 °C do 0 °C","cmc":"0,05 °C"},{"name":"","range":"od 0 °C do 30 °C","cmc":"0,04 °C"},{"name":"","range":"od 30 °C do 90 °C","cmc":"0,05 °C"}],"parameters_en":[{"name":"","range":"-40 °C to -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C to 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C to 30 °C","cmc":"0,04 °C"},{"name":"","range":"30 °C to 90 °C","cmc":"0,05 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C 至 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C 至 30 °C","cmc":"0,04 °C"},{"name":"","range":"30 °C 至 90 °C","cmc":"0,05 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C až 0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C až 30 °C","cmc":"0,04 °C"},{"name":"","range":"30 °C až 90 °C","cmc":"0,05 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a standard resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a standard resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do -30 °C CMC 0,06 °C\nod -30 °C do 0 °C CMC 0,05 °C\nod 0 °C do 30 °C CMC 0,04 °C\nod 30 °C do 90 °C CMC 0,05 °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"MKL – 02/2","norm_bases":["MKL – 02/2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od -40 °C do -30 °C CMC 0,06 °C od -30 °C do 0 °C CMC 0,05 °C od 0 °C do 30 °C CMC 0,04 °C od 30 °C do 90 °C CMC 0,05 °C Skleněné teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni -40 °C až -30 °C CMC 0,06 °C -30 °C až 0 °C CMC 0,05 °C 0 °C až 30 °C CMC 0,04 °C 30 °C až 90 °C CMC 0,05 °C MKL – 02/2 Termometry szklane Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od -40 °C do -30 °C CMC 0,06 °C od -30 °C do 0 °C CMC 0,05 °C od 0 °C do 30 °C CMC 0,04 °C od 30 °C do 90 °C CMC 0,05 °C Sklenene teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni -40 °C az -30 °C CMC 0,06 °C -30 °C az 0 °C CMC 0,05 °C 0 °C az 30 °C CMC 0,04 °C 30 °C az 90 °C CMC 0,05 °C MKL – 02/2","search_en":"Glass thermometers Calibration – temperature Comparison with a standard resistance thermometer in a liquid bath -40 °C to -30 °C CMC 0,06 °C -30 °C to 0 °C CMC 0,05 °C 0 °C to 30 °C CMC 0,04 °C 30 °C to 90 °C CMC 0,05 °C MKL – 02/2","search_zh":"玻璃温度计 校准 – 温度 在液体槽中与标准电阻温度计比较 -40 °C 至 -30 °C CMC 0,06 °C -30 °C 至 0 °C CMC 0,05 °C 0 °C 至 30 °C CMC 0,04 °C 30 °C 至 90 °C CMC 0,05 °C MKL – 02/2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"817eb6fde46411f3716900fc","lab_id":"6ade8b2fff06824761708107","country":"CZ","accr_number":"2287","accr_body":"ČIA","row_label":"3","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 0 °C","cmc":"0,06 °C"},{"name":"","range":"od 0 °C do 90 °C","cmc":"0,04 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C to 90 °C","cmc":"0,04 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C 至 90 °C","cmc":"0,04 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C až 90 °C","cmc":"0,04 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej lub komorze klimatycznej","technique_en":"Comparison with a standard resistance thermometer in a liquid bath or climatic chamber","technique_zh":"在液体槽或气候箱中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni nebo klimatické komoře","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej lub komorze klimatycznej"],"techniques_en":["Comparison with a standard resistance thermometer in a liquid bath or climatic chamber"],"techniques_zh":["在液体槽或气候箱中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni nebo klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do 0 °C CMC 0,06 °C\nod 0 °C do 90 °C CMC 0,04 °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej lub komorze klimatycznej","reference":"MKL – 02/3","norm_bases":["MKL – 02/3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej lub komorze klimatycznej od -40 °C do 0 °C CMC 0,06 °C od 0 °C do 90 °C CMC 0,04 °C Elektronické teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni nebo klimatické komoře -40 °C až 0 °C CMC 0,06 °C 0 °C až 90 °C CMC 0,04 °C MKL – 02/3 Termometry elektroniczne Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej lub komorze klimatycznej od -40 °C do 0 °C CMC 0,06 °C od 0 °C do 90 °C CMC 0,04 °C Elektronicke teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni nebo klimaticke komore -40 °C az 0 °C CMC 0,06 °C 0 °C az 90 °C CMC 0,04 °C MKL – 02/3","search_en":"Electronic thermometers Calibration – temperature Comparison with a standard resistance thermometer in a liquid bath or climatic chamber -40 °C to 0 °C CMC 0,06 °C 0 °C to 90 °C CMC 0,04 °C MKL – 02/3","search_zh":"电子温度计 校准 – 温度 在液体槽或气候箱中与标准电阻温度计比较 -40 °C 至 0 °C CMC 0,06 °C 0 °C 至 90 °C CMC 0,04 °C MKL – 02/3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5c33fbd5f6ab8d3710f873a6","lab_id":"6ade8b2fff06824761708107","country":"CZ","accr_number":"2287","accr_body":"ČIA","row_label":"1","test_object":"Przetworniki wilgotności","test_object_en":"Humidity transducers","test_object_zh":"湿度变送器","test_object_cs":"Převodníky vlhkosti","methodology":"Wzorcowanie – wielkości fizykochemiczne – wilgotność","methodology_en":"Calibration – physico-chemical quantities – humidity","methodology_zh":"校准 – 物理化学量 – 湿度","methodology_cs":"Kalibrace – fyzikálně chemické veličiny – vlhkost","parameters":[{"name":"23 °C ± 5 °C","range":"od 10 % RH do 30 % RH","cmc":"0,002 % + 1,3 % RH"},{"name":"23 °C ± 5 °C","range":"od 30 % RH do 80 % RH","cmc":"0,002 % + 1,6 % RH"},{"name":"23 °C ± 5 °C","range":"od 80 % RH do 95 % RH","cmc":"0,002 % + 2,3 % RH"}],"parameters_en":[{"name":"23 °C ± 5 °C","range":"10 % RH to 30 % RH","cmc":"0,002 % + 1,3 % RH"},{"name":"23 °C ± 5 °C","range":"30 % RH to 80 % RH","cmc":"0,002 % + 1,6 % RH"},{"name":"23 °C ± 5 °C","range":"80 % RH to 95 % RH","cmc":"0,002 % + 2,3 % RH"}],"parameters_zh":[{"name":"23 °C ± 5 °C","range":"10 % RH 至 30 % RH","cmc":"0,002 % + 1,3 % RH"},{"name":"23 °C ± 5 °C","range":"30 % RH 至 80 % RH","cmc":"0,002 % + 1,6 % RH"},{"name":"23 °C ± 5 °C","range":"80 % RH 至 95 % RH","cmc":"0,002 % + 2,3 % RH"}],"parameters_cs":[{"name":"23 °C ± 5 °C","range":"10 % RH až 30 % RH","cmc":"0,002 % + 1,3 % RH"},{"name":"23 °C ± 5 °C","range":"30 % RH až 80 % RH","cmc":"0,002 % + 1,6 % RH"},{"name":"23 °C ± 5 °C","range":"80 % RH až 95 % RH","cmc":"0,002 % + 2,3 % RH"}],"technique":"Bezpośrednie porównanie z higrometrem wzorcowym","technique_en":"Direct comparison with a standard hygrometer","technique_zh":"与标准湿度计直接比较","technique_cs":"Přímé porovnání s etalonovým vlhkoměrem","techniques":["Bezpośrednie porównanie z higrometrem wzorcowym"],"techniques_en":["Direct comparison with a standard hygrometer"],"techniques_zh":["与标准湿度计直接比较"],"techniques_cs":["Přímé porovnání s etalonovým vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne – wilgotność\nZakres:\n23 °C ± 5 °C od 10 % RH do 30 % RH CMC 0,002 % + 1,3 % RH\n23 °C ± 5 °C od 30 % RH do 80 % RH CMC 0,002 % + 1,6 % RH\n23 °C ± 5 °C od 80 % RH do 95 % RH CMC 0,002 % + 2,3 % RH\nBezpośrednie porównanie z higrometrem wzorcowym","reference":"MKL – 02/12","norm_bases":["MKL – 02/12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne – wilgotność","regulatory_area_en":"CMC for the field of measured quantity: Physico-chemical quantities – humidity","regulatory_area_zh":"被测量领域的CMC：物理化学量 – 湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny – vlhkost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przetworniki wilgotności Wzorcowanie – wielkości fizykochemiczne – wilgotność Bezpośrednie porównanie z higrometrem wzorcowym 23 °C ± 5 °C od 10 % RH do 30 % RH CMC 0,002 % + 1,3 % RH 23 °C ± 5 °C od 30 % RH do 80 % RH CMC 0,002 % + 1,6 % RH 23 °C ± 5 °C od 80 % RH do 95 % RH CMC 0,002 % + 2,3 % RH Převodníky vlhkosti Kalibrace – fyzikálně chemické veličiny – vlhkost Přímé porovnání s etalonovým vlhkoměrem 23 °C ± 5 °C 10 % RH až 30 % RH CMC 0,002 % + 1,3 % RH 23 °C ± 5 °C 30 % RH až 80 % RH CMC 0,002 % + 1,6 % RH 23 °C ± 5 °C 80 % RH až 95 % RH CMC 0,002 % + 2,3 % RH MKL – 02/12 Przetworniki wilgotnosci Wzorcowanie – wielkosci fizykochemiczne – wilgotnosc Bezposrednie porownanie z higrometrem wzorcowym 23 °C ± 5 °C od 10 % RH do 30 % RH CMC 0,002 % + 1,3 % RH 23 °C ± 5 °C od 30 % RH do 80 % RH CMC 0,002 % + 1,6 % RH 23 °C ± 5 °C od 80 % RH do 95 % RH CMC 0,002 % + 2,3 % RH Prevodniky vlhkosti Kalibrace – fyzikalne chemicke veliciny – vlhkost Prime porovnani s etalonovym vlhkomerem 23 °C ± 5 °C 10 % RH az 30 % RH CMC 0,002 % + 1,3 % RH 23 °C ± 5 °C 30 % RH az 80 % RH CMC 0,002 % + 1,6 % RH 23 °C ± 5 °C 80 % RH az 95 % RH CMC 0,002 % + 2,3 % RH MKL – 02/12","search_en":"Humidity transducers Calibration – physico-chemical quantities – humidity Direct comparison with a standard hygrometer 23 °C ± 5 °C 10 % RH to 30 % RH CMC 0,002 % + 1,3 % RH 23 °C ± 5 °C 30 % RH to 80 % RH CMC 0,002 % + 1,6 % RH 23 °C ± 5 °C 80 % RH to 95 % RH CMC 0,002 % + 2,3 % RH MKL – 02/12","search_zh":"湿度变送器 校准 – 物理化学量 – 湿度 与标准湿度计直接比较 23 °C ± 5 °C 10 % RH 至 30 % RH CMC 0,002 % + 1,3 % RH 23 °C ± 5 °C 30 % RH 至 80 % RH CMC 0,002 % + 1,6 % RH 23 °C ± 5 °C 80 % RH 至 95 % RH CMC 0,002 % + 2,3 % RH MKL – 02/12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f4f2050c22799d0e18b88a5b","lab_id":"6ade8b2fff06824761708107","country":"CZ","accr_number":"2287","accr_body":"ČIA","row_label":"2","test_object":"Higrometry elektroniczne i cyfrowe","test_object_en":"Electronic and digital hygrometers","test_object_zh":"电子和数字湿度计","test_object_cs":"Elektronické a digitální vlhkoměry","methodology":"Wzorcowanie – wielkości fizykochemiczne – wilgotność","methodology_en":"Calibration – physico-chemical quantities – humidity","methodology_zh":"校准 – 物理化学量 – 湿度","methodology_cs":"Kalibrace – fyzikálně chemické veličiny – vlhkost","parameters":[{"name":"23 °C ± 5 °C","range":"od 10 % RH do 30 % RH","cmc":"1,3 % RH"},{"name":"23 °C ± 5 °C","range":"od 30 % RH do 80 % RH","cmc":"1,6 % RH"},{"name":"23 °C ± 5 °C","range":"od 80 % RH do 95 % RH","cmc":"2,3 % RH"}],"parameters_en":[{"name":"23 °C ± 5 °C","range":"10 % RH to 30 % RH","cmc":"1,3 % RH"},{"name":"23 °C ± 5 °C","range":"30 % RH to 80 % RH","cmc":"1,6 % RH"},{"name":"23 °C ± 5 °C","range":"80 % RH to 95 % RH","cmc":"2,3 % RH"}],"parameters_zh":[{"name":"23 °C ± 5 °C","range":"10 % RH 至 30 % RH","cmc":"1,3 % RH"},{"name":"23 °C ± 5 °C","range":"30 % RH 至 80 % RH","cmc":"1,6 % RH"},{"name":"23 °C ± 5 °C","range":"80 % RH 至 95 % RH","cmc":"2,3 % RH"}],"parameters_cs":[{"name":"23 °C ± 5 °C","range":"10 % RH až 30 % RH","cmc":"1,3 % RH"},{"name":"23 °C ± 5 °C","range":"30 % RH až 80 % RH","cmc":"1,6 % RH"},{"name":"23 °C ± 5 °C","range":"80 % RH až 95 % RH","cmc":"2,3 % RH"}],"technique":"Bezpośrednie porównanie z higrometrem wzorcowym","technique_en":"Direct comparison with a standard hygrometer","technique_zh":"与标准湿度计直接比较","technique_cs":"Přímé porovnání s etalonovým vlhkoměrem","techniques":["Bezpośrednie porównanie z higrometrem wzorcowym"],"techniques_en":["Direct comparison with a standard hygrometer"],"techniques_zh":["与标准湿度计直接比较"],"techniques_cs":["Přímé porovnání s etalonovým vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne – wilgotność\nZakres:\n23 °C ± 5 °C od 10 % RH do 30 % RH CMC 1,3 % RH\n23 °C ± 5 °C od 30 % RH do 80 % RH CMC 1,6 % RH\n23 °C ± 5 °C od 80 % RH do 95 % RH CMC 2,3 % RH\nBezpośrednie porównanie z higrometrem wzorcowym","reference":"MKL – 02/13","norm_bases":["MKL – 02/13"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne – wilgotność","regulatory_area_en":"CMC for the field of measured quantity: Physico-chemical quantities – humidity","regulatory_area_zh":"被测量领域的CMC：物理化学量 – 湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny – vlhkost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Higrometry elektroniczne i cyfrowe Wzorcowanie – wielkości fizykochemiczne – wilgotność Bezpośrednie porównanie z higrometrem wzorcowym 23 °C ± 5 °C od 10 % RH do 30 % RH CMC 1,3 % RH 23 °C ± 5 °C od 30 % RH do 80 % RH CMC 1,6 % RH 23 °C ± 5 °C od 80 % RH do 95 % RH CMC 2,3 % RH Elektronické a digitální vlhkoměry Kalibrace – fyzikálně chemické veličiny – vlhkost Přímé porovnání s etalonovým vlhkoměrem 23 °C ± 5 °C 10 % RH až 30 % RH CMC 1,3 % RH 23 °C ± 5 °C 30 % RH až 80 % RH CMC 1,6 % RH 23 °C ± 5 °C 80 % RH až 95 % RH CMC 2,3 % RH MKL – 02/13 Higrometry elektroniczne i cyfrowe Wzorcowanie – wielkosci fizykochemiczne – wilgotnosc Bezposrednie porownanie z higrometrem wzorcowym 23 °C ± 5 °C od 10 % RH do 30 % RH CMC 1,3 % RH 23 °C ± 5 °C od 30 % RH do 80 % RH CMC 1,6 % RH 23 °C ± 5 °C od 80 % RH do 95 % RH CMC 2,3 % RH Elektronicke a digitalni vlhkomery Kalibrace – fyzikalne chemicke veliciny – vlhkost Prime porovnani s etalonovym vlhkomerem 23 °C ± 5 °C 10 % RH az 30 % RH CMC 1,3 % RH 23 °C ± 5 °C 30 % RH az 80 % RH CMC 1,6 % RH 23 °C ± 5 °C 80 % RH az 95 % RH CMC 2,3 % RH MKL – 02/13","search_en":"Electronic and digital hygrometers Calibration – physico-chemical quantities – humidity Direct comparison with a standard hygrometer 23 °C ± 5 °C 10 % RH to 30 % RH CMC 1,3 % RH 23 °C ± 5 °C 30 % RH to 80 % RH CMC 1,6 % RH 23 °C ± 5 °C 80 % RH to 95 % RH CMC 2,3 % RH MKL – 02/13","search_zh":"电子和数字湿度计 校准 – 物理化学量 – 湿度 与标准湿度计直接比较 23 °C ± 5 °C 10 % RH 至 30 % RH CMC 1,3 % RH 23 °C ± 5 °C 30 % RH 至 80 % RH CMC 1,6 % RH 23 °C ± 5 °C 80 % RH 至 95 % RH CMC 2,3 % RH MKL – 02/13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}