🇨🇿 EG.D, s.r.o. PL

ČIA 2255 • Brno, Czech Republic • 51 calibration items

Metrology & calibration

EG.D, s.r.o. is a calibration laboratory accredited by ČIA under number 2255 (Brno, Czech Republic). Its accreditation scope covers 51 calibration items in the following areas: Metrology & calibration. Calibrated items include: AC voltage / Sources, DC resistance / Standards, AC current / Meters, DC current / Sources. Most frequently used calibration principles: Comparison with a standard wattmeter, Direct measurement with a standard wattmeter, Direct measurement on a calibrator of inspection instruments.

At a glance

  • Accreditation number: ČIA 2255
  • Calibration items in scope: 51
  • Types of calibrated items: 45
  • Calibration principles used: 21
  • City: Brno, Czech Republic
  • Valid until: 17-10-2030
Accreditation number
2255
Accreditation body
ČIA
Address
Cejl 42/44, 602 00 Brno
City
Brno, Czech Republic
Division
Laboratorium wzorcujące Brno
Valid until
17-10-2030

What this laboratory calibrates (45)

Calibration principles (21)

Certificate information

Certificate date
17.10.2025

Accreditation scope — calibration items (51)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 DC voltage / Meters Calibration – electrical quantities
0 mV to 100 mV · CMC 0,0015 % + 0,3 µV 100 mV to 1 V · CMC 0,0005 % + 0,3 µV 1 V to 10 V · CMC 0,0005 % + 5 µV 10 V to 100 V · CMC 0,0008 % + 30 µV 100 V to 1000 V · CMC 0,0010 % + 100 µV
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard multimeter KP - 01, KP - 05, KP - 06
2 AC voltage / Sources Calibration – electrical quantities
0 mV to 100 mV · CMC 0,0010 % + 0,3 µV 100 mV to 1 V · CMC 0,0005 % + 0,3 µV 1 V to 10 V · CMC 0,0005 % + 5 µV 10 V to 100 V · CMC 0,0008 % + 30 µV 100 V to 1000 V · CMC 0,0010 % + 100 µV 1 kV to 10 kV · CMC 0,35 % + 5 V 10 kV to 40 kV · CMC 0,58 % + 10 V
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard multimeter KP - 08
3 AC voltage / Meters Calibration – electrical quantities
10 Hz to 40 Hz — 10 µV to 10 mV · CMC 0,07 % + 3,5 µV 40 Hz to 1 kHz — 10 µV to 10 mV · CMC 0,04 % + 1,3 µV 1 kHz to 20 kHz — 10 µV to 10 mV · CMC 0,05 % + 1,3 µV 10 Hz to 40 Hz — 10 mV to 10 V · CMC 0,015 % + 5,5 µV 40 Hz to 1 kHz — 10 mV to 10 V · CMC 0,010 % + 3,0 µV 1 kHz to 20 kHz — 10 mV to 10 V · CMC 0,020 % + 4,0 µV 10 Hz to 40 Hz — 10 V to 100 V · CMC 0,028 % 40 Hz to 70 Hz — 10 V to 100 V · CMC 0,015 % 70 Hz to 20 kHz — 10 V to 100 V · CMC 0,023 % 10 Hz to 40 Hz — 100 V to 600 V · CMC 0,035 % 40 Hz to 70 Hz — 100 V to 600 V · CMC 0,015 % 70 Hz to 1 kHz — 100 V to 600 V · CMC 0,035 % 1 kHz to 20 kHz — 100 V to 600 V · CMC 0,071 % 10 Hz to 1 kHz — 600 V to 700 V · CMC 0,035 % 1 kHz to 20 kHz — 600 V to 700 V · CMC 0,071 % 20 Hz to 1 kHz — 700 V to 1000 V · CMC 0,04 %
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard multimeter KP - 02, KP - 05, KP - 06
4 AC voltage / Sources Calibration – electrical quantities
10 Hz to 40 Hz — 10 µV to 10 mV · CMC 0,07 % + 3,5 µV 40 Hz to 1 kHz — 10 µV to 10 mV · CMC 0,04 % + 1,3 µV 1 kHz to 20 kHz — 10 µV to 10 mV · CMC 0,05 % + 1,3 µV 10 Hz to 40 Hz — 10 mV to 10 V · CMC 0,015 % + 5,5 µV 40 Hz to 1 kHz — 10 mV to 10 V · CMC 0,010 % + 3,0 µV 1 kHz to 20 kHz — 10 mV to 10 V · CMC 0,020 % + 4,0 µV 10 Hz to 40 Hz — 10 V to 100 V · CMC 0,028 % 40 Hz to 70 Hz — 10 V to 100 V · CMC 0,015 % 70 Hz to 20 kHz — 10 V to 100 V · CMC 0,023 % 10 Hz to 40 Hz — 100 V to 600 V · CMC 0,050 % 40 Hz to 70 Hz — 100 V to 600 V · CMC 0,015 % 70 Hz to 1 kHz — 100 V to 600 V · CMC 0,046 % 1 kHz to 20 kHz — 100 V to 600 V · CMC 0,071 % 10 Hz to 1 kHz — 600 V to 700 V · CMC 0,035 % 1 kHz to 20 kHz — 600 V to 700 V · CMC 0,071 % 40 Hz to 1 kHz — 700 V to 1000 V · CMC 0,2 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard multimeter KP - 08
5 AC voltage / Sources Calibration – electrical quantities
45 Hz to 55 Hz — 1 kV to 40 kV · CMC 0,6 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard multimeter and a voltage divider KP - 08
6 DC current / Meters Calibration – electrical quantities
0 µA to 1 µA · CMC 0,05 % + 0,1 nA 1 µA to 200 µA · CMC 0,0043 % 200 µA to 100 mA · CMC 0,0047 % 100 mA · CMC 0,0020 % 100 mA to 1 A · CMC 0,0035 % 1 A · CMC 0,0020 % 1 A to 30 A · CMC 0,0050 % 30 A to 90 A · CMC 0,015 %
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard multimeter and a shunt KP - 03, KP - 05, KP - 06
7 DC current / Clamp meters Calibration – electrical quantities
0,5 A to 3000 A · CMC 0,6 %
CMC for the field of measured quantity: Electrical quantities
Indirect measurement with a calibrator with a current coil KP - 07
8 DC current / Sources Calibration – electrical quantities
0 µA to 1 µA · CMC 0,05 % + 0,1 nA 1 µA to 10 µA · CMC 0,0043 % 10 µA to 100 µA · CMC 0,0036 % 100 µA to 10 mA · CMC 0,0030 % 10 mA to 100 mA · CMC 0,0047 % 100 mA to 1 A · CMC 0,0035 % 1 A to 10 A · CMC 0,0050 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a multimeter KP - 08
9 DC current / Sources Calibration – electrical quantities
10 A to 200 A · CMC 0,015 %
CMC for the field of measured quantity: Electrical quantities
Measurement with a multimeter and a shunt KP - 08
10 AC current / Meters Calibration – electrical quantities
20 Hz to 100 Hz — 0,1 µA to 1 µA · CMC 0,2 %
CMC for the field of measured quantity: Electrical quantities
Indirect generation using a voltage calibrator and a resistance standard KP - 04, KP - 05, KP - 06
11 AC current / Meters Calibration – electrical quantities
40 Hz to 1 kHz — 1 µA to 100 µA · CMC 0,08 % 1 kHz to 5 kHz — 1 µA to 100 µA · CMC 0,09 % 20 Hz to 100 Hz — 100 µA to 10 mA · CMC 0,08 % 100 Hz to 5 kHz — 100 µA to 10 mA · CMC 0,05 % 40 Hz to 70 Hz — 10 mA to 100 mA · CMC 0,02 % 70 Hz to 5 kHz — 10 mA to 100 mA · CMC 0,05 % 40 Hz to 70 Hz — 100 mA to 1 A · CMC 0,015 % 70 Hz to 5 kHz — 100 mA to 1 A · CMC 0,050 % 40 Hz to 70 Hz — 1 A to 90 A · CMC 0,015 % 70 Hz to 400 Hz — 1 A to 30 A · CMC 0,07 % 70 Hz to 400 Hz — 30 A to 90 A · CMC 0,14 %
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard multimeter with a shunt KP - 04, KP - 05, KP - 06
12 AC current / Clamp meters Calibration – electrical quantities
40 Hz to 60 Hz — 0,01 A to 3000 A · CMC 0,5 %
CMC for the field of measured quantity: Electrical quantities
Indirect measurement with a calibrator with a current coil KP - 07
13 AC current / Sources Calibration – electrical quantities
40 Hz to 1 kHz — 1 µA to 100 µA · CMC 0,08 % 1 kHz to 5 kHz — 1 µA to 100 µA · CMC 0,09 % 20 Hz to 100 Hz — 100 µA to 10 mA · CMC 0,08 % 100 Hz to 5 kHz — 100 µA to 10 mA · CMC 0,05 % 40 Hz to 70 Hz — 10 mA to 100 mA · CMC 0,02 % 70 Hz to 5 kHz — 10 mA to 100 mA · CMC 0,05 % 40 Hz to 70 Hz — 100 mA to 1 A · CMC 0,015 % 70 Hz to 5 kHz — 100 mA to 1 A · CMC 0,050 % 40 Hz to 70 Hz — 1 A to 200 A · CMC 0,015 % 70 Hz to 400 Hz — 1 A to 10 A · CMC 0,03 % 70 Hz to 400 Hz — 10 A to 200 A · CMC 0,06 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a multimeter, with a multimeter with a shunt KP - 08
14 DC resistance / Meters Calibration – electrical quantities
60 µΩ · CMC 0,01 µΩ 100 µΩ · CMC 0,01 µΩ 300 µΩ · CMC 0,02 µΩ 600 µΩ · CMC 0,12 µΩ 1 mΩ · CMC 0,02 µΩ 2 mΩ · CMC 0,3 µΩ 5 mΩ · CMC 0,8 µΩ 10 mΩ · CMC 0,08 µΩ 1 mΩ to 100 mΩ · CMC 0,004 % + 0,5 µΩ 100 mΩ to 200 mΩ · CMC 0,003 % + 0,5 µΩ 200 mΩ to 1 Ω · CMC 0,0006 % + 0,5 µΩ 1 Ω to 100 Ω · CMC 0,0015 % + 5 µΩ 100 Ω to 100 kΩ · CMC 0,0012 % 100 kΩ to 1 MΩ · CMC 0,0020 % 1 MΩ to 10 MΩ · CMC 0,0070 % 10 MΩ to 100 MΩ · CMC 0,060 % 100 MΩ to 1 GΩ · CMC 0,15 % 1 GΩ to 10 GΩ · CMC 0,3 % 10 GΩ to 100 GΩ · CMC 0,5 % 100 GΩ to 1 TΩ · CMC 1 % 1 TΩ to 10 TΩ · CMC 2 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of resistance standards or a resistance decade KP - 05, KP - 06, KP - 09, KP - 16
15 DC resistance / Standards Calibration – electrical quantities
600 µΩ to 1 mΩ · CMC 0,12 µΩ 100 MΩ to 20 GΩ · CMC 0,2 %
CMC for the field of measured quantity: Electrical quantities
Voltammeter–ammeter method KP - 09, KP - 16
16 DC resistance / Standards Calibration – electrical quantities
1 mΩ to 10 mΩ · CMC 0,008 % + 0,5 µΩ 10 mΩ to 100 mΩ · CMC 0,004 % + 0,5 µΩ 100 mΩ to 10 Ω · CMC 0,003 % + 0,5 µΩ
CMC for the field of measured quantity: Electrical quantities
Comparison by the ratio method KP - 09, KP - 16
17 DC resistance / Standards Calibration – electrical quantities
10 Ω to 100 Ω · CMC 0,0015 % + 5 µΩ 100 Ω to 100 kΩ · CMC 0,0012 % 100 kΩ to 1 MΩ · CMC 0,0020 % 1 MΩ to 10 MΩ · CMC 0,0070 % 10 MΩ to 100 MΩ · CMC 0,060 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a multimeter KP - 09, KP - 16
18 AC active power, single-phase, three-phase / Power meters and sources Calibration – electrical quantities
1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360° — 0,02 W to 36 kW · CMC 0,03 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a standard calibrator / measurement with a standard wattmeter KP - 11
19 AC active power, single-phase, three-phase / Clamp power meters Calibration – electrical quantities
1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360° — 0,1 W to 600 kW · CMC 0,6 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a standard calibrator with a coil KP - 11
20 AC reactive power, single-phase, three-phase / Power meters and sources Calibration – electrical quantities
1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360° — 0,02 Var to 36 kVar · CMC 0,03 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a standard calibrator / measurement with a standard wattmeter KP - 11
21 AC reactive power, single-phase, three-phase / Clamp power meters Calibration – electrical quantities
1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360° — 0,1 Var to 600 kVar · CMC 0,6 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a standard calibrator with a coil KP - 11
22 AC apparent power, single-phase, three-phase / Power meters and sources Calibration – electrical quantities
1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz — 0,02 VA to 36 kVA · CMC 0,03 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a standard calibrator / measurement with a standard wattmeter KP - 11
23 AC apparent power, single-phase, three-phase / Clamp power meters Calibration – electrical quantities
1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz — 0,1 VA to 600 kVA · CMC 0,8 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a standard calibrator with a coil KP - 11
24 DC power, single-phase, three-phase / Power meters and sources Calibration – electrical quantities
1 V to 400 V; 0.02 A to 90 A — 0,1 W to 36 kW · CMC 0,06 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a standard calibrator / measurement with a standard wattmeter KP - 11
25 DC power, single-phase, three-phase / Clamp power meters Calibration – electrical quantities
1 V to 400 V; 0.02 A to 90 A — 0,1 W to 600 kW · CMC 0,8 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a standard calibrator with a coil KP - 11
26 Fundamental component / Meters of harmonic and interharmonic voltage components Calibration – electrical quantities
50 Hz — 10 V to 360 V · CMC 0,02 %
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard wattmeter KP - 14
27 Amplitude of higher signal components / Meters of harmonic and interharmonic voltage components Calibration – electrical quantities
15 Hz to 1 kHz — 0 %·U₁ to 30 %·U₁ · CMC 0,05 % 1 kHz to 2,5 kHz — 0 %·U₁ to 30 %·U₁ · CMC 0,1 %
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard wattmeter KP - 14
28 Fundamental component / Meters of harmonic and interharmonic current components Calibration – electrical quantities
50 Hz — 0,01 A to 20 A · CMC 0,02 %
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard wattmeter KP - 14
29 Amplitude of higher signal components / Meters of harmonic and interharmonic current components Calibration – electrical quantities
15 Hz to 2,5 Hz — 0 %·I₁ to 30 %·I₁ · CMC 0,1 %
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard wattmeter KP - 14
30 Fundamental component / Sources of harmonic and interharmonic voltage components Calibration – electrical quantities
50 Hz — 10 V to 360 V · CMC 0,02 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard wattmeter KP - 14
31 Amplitude of higher signal components / Sources of harmonic and interharmonic voltage components Calibration – electrical quantities
15 Hz to 1 kHz — 0 %·U₁ to 30 %·U₁ · CMC 0,05 % 1 kHz to 2,5 kHz — 0 %·U₁ to 30 %·U₁ · CMC 0,1 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard wattmeter KP - 14
32 Fundamental component / Sources of harmonic and interharmonic current components Calibration – electrical quantities
50 Hz — 0,01 A to 20 A · CMC 0,02 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard wattmeter KP - 14
33 Amplitude of higher signal components / Sources of harmonic and interharmonic current components Calibration – electrical quantities
15 Hz to 2,5 kHz — 0 %·I₁ to 30 %·I₁ · CMC 0,1 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard wattmeter KP - 14
34 Flicker / Meters Calibration – electrical quantities
230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 — 0,5 ·Pₛₜ to 6 ·Pₛₜ · CMC 0,014·Pₛₜ
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard wattmeter KP - 13
35 Flicker / Sources Calibration – electrical quantities
230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 — 0,5 ·Pₛₜ to 6 ·Pₛₜ · CMC 0,014·Pₛₜ
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard wattmeter KP - 13
36 Inspection instruments / Protective loop impedance, mains impedance Calibration – electrical quantities
50 Hz — 25 mΩ to 100 mΩ · CMC 5 mΩ 50 Hz — 100 mΩ to 500 mΩ · CMC 8 mΩ 50 Hz — 500 mΩ to 1 Ω · CMC 10 mΩ 50 Hz — 1 Ω to 10 Ω · CMC 0,5 % 50 Hz — 10 Ω to 2000 Ω · CMC 0,3 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a calibrator of inspection instruments KP - 16
37 Inspection instruments / Power consumption Calibration – electrical quantities
50 Hz — 120 VA to 2000 VA · CMC 1 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a calibrator of inspection instruments KP - 16
38 Inspection instruments / Tripping current of residual current devices Calibration – electrical quantities
50 Hz — 3 mA to 3 A · CMC 1,2 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a calibrator of inspection instruments KP - 16
39 Inspection instruments / Tripping time of residual current devices Calibration – electrical quantities
50 Hz — 20 ms to 1 s · CMC 0,02 % + 0,25 ms
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a calibrator of inspection instruments KP - 16
40 Inspection instruments / Leakage current – passive, differential, substitute, touch Calibration – electrical quantities
50 Hz — 0,1 mA to 30 mA · CMC 0,3 % + 2 µA
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a calibrator of inspection instruments KP - 16
41 Inspection instruments / Leakage currents – sources Calibration – electrical quantities
DC, 10 Hz to 400 Hz — 0,1 mA to 300 mA · CMC 0,3 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a calibrator of inspection instruments KP - 16
42 Impedance modulus / Standards and meters Calibration – electrical quantities
40 Hz to 400 Hz — 20 mΩ to 1 Ω · CMC 0,1 % 400 Hz to 5 kHz — 20 mΩ to 1 Ω · CMC 0,3 % 40 Hz to 400 Hz — 1 Ω to 1 kΩ · CMC 0,02 % 400 Hz to 5 kHz — 1 Ω to 1 kΩ · CMC 0,05 % 40 Hz to 400 Hz — 1 kΩ to 100 kΩ · CMC 0,03 % 400 Hz to 1 kHz — 1 kΩ to 100 kΩ · CMC 0,06 %
CMC for the field of measured quantity: Electrical quantities
Indirect measurement by the voltammeter–ammeter method / direct measurement of a standard KP - 18
43 Phase angle U-I / Meters Calibration – electrical quantities
1 V to 400 V, 40 Hz to 70 Hz, 0.1 A to 90 A — 0 ° to 359,9 ° · CMC 0,01 °
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard wattmeter KP - 11
44 Power factor / Meters Calibration – electrical quantities
0,1 to 1 · CMC 0,2 %
CMC for the field of measured quantity: Electrical quantities
Comparison with a standard wattmeter KP - 11
45 Phase angle U-I / Sources Calibration – electrical quantities
1 V to 400 V, 40 Hz to 70 Hz, 0.03 A to 100 A — 0 ° to 359,9 ° · CMC 0,01 °
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard wattmeter KP - 11
46 Power factor / Sources Calibration – electrical quantities
0,1 to 1 · CMC 0,2 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard wattmeter KP - 11
47 Frequency / AC voltage frequency meters Calibration – time and frequency quantities
0,1 V to 10 V — 0,5 Hz to 10 Hz · CMC 0,001 % 0,1 V to 10 V — 10 Hz to 10 MHz · CMC 0,001 % 10 V to 750 V — 10 Hz to 10 MHz · CMC 0,01 % 0,1 V to 10 V — 10 MHz to 20 MHz · CMC 0,001 %
CMC for the field of measured quantity: Time and frequency quantities
Comparison with a standard counter KP - 12
48 Frequency / AC current frequency meters Calibration – time and frequency quantities
0,05 A to 90 A — 20 Hz to 1 kHz · CMC 0,01 %
CMC for the field of measured quantity: Time and frequency quantities
Comparison with a standard wattmeter KP - 12
49 Frequency / AC voltage sources Calibration – time and frequency quantities
0,1 V to 10 V — 0,5 Hz to 10 Hz · CMC 0,001 % 0,1 V to 10 V — 10 Hz to 10 MHz · CMC 0,001 % 10 V to 750 V — 10 Hz to 10 MHz · CMC 0,01 % 0,1 V to 10 V — 10 MHz to 20 MHz · CMC 0,001 %
CMC for the field of measured quantity: Time and frequency quantities
Direct measurement with a standard counter KP - 12
50 Frequency / AC current sources Calibration – time and frequency quantities
0,05 A to 90 A — 20 Hz to 1 kHz · CMC 0,01 %
CMC for the field of measured quantity: Time and frequency quantities
Direct measurement with a standard wattmeter KP - 12
51 Time interval / Calibrators of inspection instruments Calibration – time and frequency quantities
0,1 V to 10 V — 1 ms to 5 s · CMC 0,001 %
CMC for the field of measured quantity: Time and frequency quantities
Direct measurement with a standard counter KP - 12

Reference standards (15)

KP - 01
KP - 02
KP - 03
KP - 04
KP - 05
KP - 06
KP - 07
KP - 08
KP - 09
KP - 11
KP - 12
KP - 13
KP - 14
KP - 16
KP - 18

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2255