{"lab":{"_id":"6ade8b2bff06824761708100","accr_number":"2255","country":"CZ","accr_body":"ČIA","address":"Cejl 42/44, 602 00 Brno","categories":["metrology"],"city":"Brno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.6202,49.1982]},"map_coord":[49.1982,16.6202],"map_geo":"cai-mapa","methods_count":51,"name":"EG.D, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie wielkości elektrycznych oraz wielkości czasu i częstotliwości, w zakresie określonym w załączniku do świadectwa.","search_text":"eg.d, s.r.o. cejl 42/44, 602 00 brno 2255","source_page_url":"https://www.cai.cz/?subjekt=2255-eg-d-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"17-10-2030","website":"www.egd.cz","certificate_date":"17.10.2025","certificate_no":"515/2025","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie wielkości elektrycznych oraz wielkości czasu i częstotliwości, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of electrical quantities and time and frequency quantities, to the extent specified in the appendix to this Certificate.","zh":"电学量以及时间和频率量领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru elektrických veličin a veličin času a frekvence, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące Brno","lab_division_cs":"Kalibrační laboratoř Brno","lab_division_en":"Calibration Laboratory Brno","lab_division_zh":"布尔诺校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"CPM","pl":"liczba zmian na minutę","en":"number of changes per minute","zh":"每分钟变化次数","cs":"počet změn za minutu"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"4bc9bb0bdc2fe35b3a79cde16a364da1ef80551acc5947310ed927f9adb3cf47","source_pdf_url":"https://www.cai.cz/OA/pdf/515_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"2b26fa68f5014e61b7f7a53b","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / mierniki","test_object_en":"DC voltage / Meters","test_object_zh":"直流电压 / 测量仪器","test_object_cs":"Stejnosměrné napětí / Měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,0015 % + 0,3 µV"},{"name":"","range":"od 100 mV do 1 V","cmc":"0,0005 % + 0,3 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,0005 % + 5 µV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,0008 % + 30 µV"},{"name":"","range":"od 100 V do 1000 V","cmc":"0,0010 % + 100 µV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,0015 % + 0,3 µV"},{"name":"","range":"100 mV to 1 V","cmc":"0,0005 % + 0,3 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0005 % + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,0008 % + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"0,0010 % + 100 µV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,0015 % + 0,3 µV"},{"name":"","range":"100 mV 至 1 V","cmc":"0,0005 % + 0,3 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,0005 % + 5 µV"},{"name":"","range":"10 V 至 100 V","cmc":"0,0008 % + 30 µV"},{"name":"","range":"100 V 至 1000 V","cmc":"0,0010 % + 100 µV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,0015 % + 0,3 µV"},{"name":"","range":"100 mV až 1 V","cmc":"0,0005 % + 0,3 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,0005 % + 5 µV"},{"name":"","range":"10 V až 100 V","cmc":"0,0008 % + 30 µV"},{"name":"","range":"100 V až 1000 V","cmc":"0,0010 % + 100 µV"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a standard multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a standard multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,0015 % + 0,3 µV\nod 100 mV do 1 V CMC 0,0005 % + 0,3 µV\nod 1 V do 10 V CMC 0,0005 % + 5 µV\nod 10 V do 100 V CMC 0,0008 % + 30 µV\nod 100 V do 1000 V CMC 0,0010 % + 100 µV\nPorównanie z multimetrem wzorcowym","reference":"KP - 01, KP - 05, KP - 06","norm_bases":["KP - 01","KP - 05","KP - 06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / mierniki Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0015 % + 0,3 µV od 100 mV do 1 V CMC 0,0005 % + 0,3 µV od 1 V do 10 V CMC 0,0005 % + 5 µV od 10 V do 100 V CMC 0,0008 % + 30 µV od 100 V do 1000 V CMC 0,0010 % + 100 µV Stejnosměrné napětí / Měřidla Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 0 mV až 100 mV CMC 0,0015 % + 0,3 µV 100 mV až 1 V CMC 0,0005 % + 0,3 µV 1 V až 10 V CMC 0,0005 % + 5 µV 10 V až 100 V CMC 0,0008 % + 30 µV 100 V až 1000 V CMC 0,0010 % + 100 µV KP - 01, KP - 05, KP - 06 Napiecie stale / mierniki Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0015 % + 0,3 µV od 100 mV do 1 V CMC 0,0005 % + 0,3 µV od 1 V do 10 V CMC 0,0005 % + 5 µV od 10 V do 100 V CMC 0,0008 % + 30 µV od 100 V do 1000 V CMC 0,0010 % + 100 µV Stejnosmerne napeti / Meridla Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 0 mV az 100 mV CMC 0,0015 % + 0,3 µV 100 mV az 1 V CMC 0,0005 % + 0,3 µV 1 V az 10 V CMC 0,0005 % + 5 µV 10 V az 100 V CMC 0,0008 % + 30 µV 100 V az 1000 V CMC 0,0010 % + 100 µV KP - 01, KP - 05, KP - 06","search_en":"DC voltage / Meters Calibration – electrical quantities Comparison with a standard multimeter 0 mV to 100 mV CMC 0,0015 % + 0,3 µV 100 mV to 1 V CMC 0,0005 % + 0,3 µV 1 V to 10 V CMC 0,0005 % + 5 µV 10 V to 100 V CMC 0,0008 % + 30 µV 100 V to 1000 V CMC 0,0010 % + 100 µV KP - 01, KP - 05, KP - 06","search_zh":"直流电压 / 测量仪器 校准 – 电学量 与标准万用表比较 0 mV 至 100 mV CMC 0,0015 % + 0,3 µV 100 mV 至 1 V CMC 0,0005 % + 0,3 µV 1 V 至 10 V CMC 0,0005 % + 5 µV 10 V 至 100 V CMC 0,0008 % + 30 µV 100 V 至 1000 V CMC 0,0010 % + 100 µV KP - 01, KP - 05, KP - 06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a58d2933d9ec5ce71a9fdc2e","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"1","test_object":"Napięcie przemienne / źródła","test_object_en":"AC voltage / Sources","test_object_zh":"交流电压 / 电源","test_object_cs":"Střídavé napětí / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,0010 % + 0,3 µV"},{"name":"","range":"od 100 mV do 1 V","cmc":"0,0005 % + 0,3 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,0005 % + 5 µV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,0008 % + 30 µV"},{"name":"","range":"od 100 V do 1000 V","cmc":"0,0010 % + 100 µV"},{"name":"","range":"od 1 kV do 10 kV","cmc":"0,35 % + 5 V"},{"name":"","range":"od 10 kV do 40 kV","cmc":"0,58 % + 10 V"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,0010 % + 0,3 µV"},{"name":"","range":"100 mV to 1 V","cmc":"0,0005 % + 0,3 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0005 % + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,0008 % + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"0,0010 % + 100 µV"},{"name":"","range":"1 kV to 10 kV","cmc":"0,35 % + 5 V"},{"name":"","range":"10 kV to 40 kV","cmc":"0,58 % + 10 V"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,0010 % + 0,3 µV"},{"name":"","range":"100 mV 至 1 V","cmc":"0,0005 % + 0,3 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,0005 % + 5 µV"},{"name":"","range":"10 V 至 100 V","cmc":"0,0008 % + 30 µV"},{"name":"","range":"100 V 至 1000 V","cmc":"0,0010 % + 100 µV"},{"name":"","range":"1 kV 至 10 kV","cmc":"0,35 % + 5 V"},{"name":"","range":"10 kV 至 40 kV","cmc":"0,58 % + 10 V"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,0010 % + 0,3 µV"},{"name":"","range":"100 mV až 1 V","cmc":"0,0005 % + 0,3 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,0005 % + 5 µV"},{"name":"","range":"10 V až 100 V","cmc":"0,0008 % + 30 µV"},{"name":"","range":"100 V až 1000 V","cmc":"0,0010 % + 100 µV"},{"name":"","range":"1 kV až 10 kV","cmc":"0,35 % + 5 V"},{"name":"","range":"10 kV až 40 kV","cmc":"0,58 % + 10 V"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement with a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement with a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,0010 % + 0,3 µV\nod 100 mV do 1 V CMC 0,0005 % + 0,3 µV\nod 1 V do 10 V CMC 0,0005 % + 5 µV\nod 10 V do 100 V CMC 0,0008 % + 30 µV\nod 100 V do 1000 V CMC 0,0010 % + 100 µV\nod 1 kV do 10 kV CMC 0,35 % + 5 V\nod 10 kV do 40 kV CMC 0,58 % + 10 V\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP - 08","norm_bases":["KP - 08"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0010 % + 0,3 µV od 100 mV do 1 V CMC 0,0005 % + 0,3 µV od 1 V do 10 V CMC 0,0005 % + 5 µV od 10 V do 100 V CMC 0,0008 % + 30 µV od 100 V do 1000 V CMC 0,0010 % + 100 µV od 1 kV do 10 kV CMC 0,35 % + 5 V od 10 kV do 40 kV CMC 0,58 % + 10 V Střídavé napětí / Zdroje Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 mV až 100 mV CMC 0,0010 % + 0,3 µV 100 mV až 1 V CMC 0,0005 % + 0,3 µV 1 V až 10 V CMC 0,0005 % + 5 µV 10 V až 100 V CMC 0,0008 % + 30 µV 100 V až 1000 V CMC 0,0010 % + 100 µV 1 kV až 10 kV CMC 0,35 % + 5 V 10 kV až 40 kV CMC 0,58 % + 10 V KP - 08 Napiecie przemienne / zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0010 % + 0,3 µV od 100 mV do 1 V CMC 0,0005 % + 0,3 µV od 1 V do 10 V CMC 0,0005 % + 5 µV od 10 V do 100 V CMC 0,0008 % + 30 µV od 100 V do 1000 V CMC 0,0010 % + 100 µV od 1 kV do 10 kV CMC 0,35 % + 5 V od 10 kV do 40 kV CMC 0,58 % + 10 V Stridave napeti / Zdroje Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 mV az 100 mV CMC 0,0010 % + 0,3 µV 100 mV az 1 V CMC 0,0005 % + 0,3 µV 1 V az 10 V CMC 0,0005 % + 5 µV 10 V az 100 V CMC 0,0008 % + 30 µV 100 V az 1000 V CMC 0,0010 % + 100 µV 1 kV az 10 kV CMC 0,35 % + 5 V 10 kV az 40 kV CMC 0,58 % + 10 V KP - 08","search_en":"AC voltage / Sources Calibration – electrical quantities Direct measurement with a standard multimeter 0 mV to 100 mV CMC 0,0010 % + 0,3 µV 100 mV to 1 V CMC 0,0005 % + 0,3 µV 1 V to 10 V CMC 0,0005 % + 5 µV 10 V to 100 V CMC 0,0008 % + 30 µV 100 V to 1000 V CMC 0,0010 % + 100 µV 1 kV to 10 kV CMC 0,35 % + 5 V 10 kV to 40 kV CMC 0,58 % + 10 V KP - 08","search_zh":"交流电压 / 电源 校准 – 电学量 用标准万用表直接测量 0 mV 至 100 mV CMC 0,0010 % + 0,3 µV 100 mV 至 1 V CMC 0,0005 % + 0,3 µV 1 V 至 10 V CMC 0,0005 % + 5 µV 10 V 至 100 V CMC 0,0008 % + 30 µV 100 V 至 1000 V CMC 0,0010 % + 100 µV 1 kV 至 10 kV CMC 0,35 % + 5 V 10 kV 至 40 kV CMC 0,58 % + 10 V KP - 08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"483b585a7dfc78986c9d0295","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / mierniki","test_object_en":"AC voltage / Meters","test_object_zh":"交流电压 / 测量仪器","test_object_cs":"Střídavé napětí / Měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 40 Hz","range":"od 10 µV do 10 mV","cmc":"0,07 % + 3,5 µV"},{"name":"40 Hz do 1 kHz","range":"od 10 µV do 10 mV","cmc":"0,04 % + 1,3 µV"},{"name":"1 kHz do 20 kHz","range":"od 10 µV do 10 mV","cmc":"0,05 % + 1,3 µV"},{"name":"10 Hz do 40 Hz","range":"od 10 mV do 10 V","cmc":"0,015 % + 5,5 µV"},{"name":"40 Hz do 1 kHz","range":"od 10 mV do 10 V","cmc":"0,010 % + 3,0 µV"},{"name":"1 kHz do 20 kHz","range":"od 10 mV do 10 V","cmc":"0,020 % + 4,0 µV"},{"name":"10 Hz do 40 Hz","range":"od 10 V do 100 V","cmc":"0,028 %"},{"name":"40 Hz do 70 Hz","range":"od 10 V do 100 V","cmc":"0,015 %"},{"name":"70 Hz do 20 kHz","range":"od 10 V do 100 V","cmc":"0,023 %"},{"name":"10 Hz do 40 Hz","range":"od 100 V do 600 V","cmc":"0,035 %"},{"name":"40 Hz do 70 Hz","range":"od 100 V do 600 V","cmc":"0,015 %"},{"name":"70 Hz do 1 kHz","range":"od 100 V do 600 V","cmc":"0,035 %"},{"name":"1 kHz do 20 kHz","range":"od 100 V do 600 V","cmc":"0,071 %"},{"name":"10 Hz do 1 kHz","range":"od 600 V do 700 V","cmc":"0,035 %"},{"name":"1 kHz do 20 kHz","range":"od 600 V do 700 V","cmc":"0,071 %"},{"name":"20 Hz do 1 kHz","range":"od 700 V do 1000 V","cmc":"0,04 %"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"10 µV to 10 mV","cmc":"0,07 % + 3,5 µV"},{"name":"40 Hz to 1 kHz","range":"10 µV to 10 mV","cmc":"0,04 % + 1,3 µV"},{"name":"1 kHz to 20 kHz","range":"10 µV to 10 mV","cmc":"0,05 % + 1,3 µV"},{"name":"10 Hz to 40 Hz","range":"10 mV to 10 V","cmc":"0,015 % + 5,5 µV"},{"name":"40 Hz to 1 kHz","range":"10 mV to 10 V","cmc":"0,010 % + 3,0 µV"},{"name":"1 kHz to 20 kHz","range":"10 mV to 10 V","cmc":"0,020 % + 4,0 µV"},{"name":"10 Hz to 40 Hz","range":"10 V to 100 V","cmc":"0,028 %"},{"name":"40 Hz to 70 Hz","range":"10 V to 100 V","cmc":"0,015 %"},{"name":"70 Hz to 20 kHz","range":"10 V to 100 V","cmc":"0,023 %"},{"name":"10 Hz to 40 Hz","range":"100 V to 600 V","cmc":"0,035 %"},{"name":"40 Hz to 70 Hz","range":"100 V to 600 V","cmc":"0,015 %"},{"name":"70 Hz to 1 kHz","range":"100 V to 600 V","cmc":"0,035 %"},{"name":"1 kHz to 20 kHz","range":"100 V to 600 V","cmc":"0,071 %"},{"name":"10 Hz to 1 kHz","range":"600 V to 700 V","cmc":"0,035 %"},{"name":"1 kHz to 20 kHz","range":"600 V to 700 V","cmc":"0,071 %"},{"name":"20 Hz to 1 kHz","range":"700 V to 1000 V","cmc":"0,04 %"}],"parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"10 µV 至 10 mV","cmc":"0,07 % + 3,5 µV"},{"name":"40 Hz 至 1 kHz","range":"10 µV 至 10 mV","cmc":"0,04 % + 1,3 µV"},{"name":"1 kHz 至 20 kHz","range":"10 µV 至 10 mV","cmc":"0,05 % + 1,3 µV"},{"name":"10 Hz 至 40 Hz","range":"10 mV 至 10 V","cmc":"0,015 % + 5,5 µV"},{"name":"40 Hz 至 1 kHz","range":"10 mV 至 10 V","cmc":"0,010 % + 3,0 µV"},{"name":"1 kHz 至 20 kHz","range":"10 mV 至 10 V","cmc":"0,020 % + 4,0 µV"},{"name":"10 Hz 至 40 Hz","range":"10 V 至 100 V","cmc":"0,028 %"},{"name":"40 Hz 至 70 Hz","range":"10 V 至 100 V","cmc":"0,015 %"},{"name":"70 Hz 至 20 kHz","range":"10 V 至 100 V","cmc":"0,023 %"},{"name":"10 Hz 至 40 Hz","range":"100 V 至 600 V","cmc":"0,035 %"},{"name":"40 Hz 至 70 Hz","range":"100 V 至 600 V","cmc":"0,015 %"},{"name":"70 Hz 至 1 kHz","range":"100 V 至 600 V","cmc":"0,035 %"},{"name":"1 kHz 至 20 kHz","range":"100 V 至 600 V","cmc":"0,071 %"},{"name":"10 Hz 至 1 kHz","range":"600 V 至 700 V","cmc":"0,035 %"},{"name":"1 kHz 至 20 kHz","range":"600 V 至 700 V","cmc":"0,071 %"},{"name":"20 Hz 至 1 kHz","range":"700 V 至 1000 V","cmc":"0,04 %"}],"parameters_cs":[{"name":"10 Hz až 40 Hz","range":"10 µV až 10 mV","cmc":"0,07 % + 3,5 µV"},{"name":"40 Hz až 1 kHz","range":"10 µV až 10 mV","cmc":"0,04 % + 1,3 µV"},{"name":"1 kHz až 20 kHz","range":"10 µV až 10 mV","cmc":"0,05 % + 1,3 µV"},{"name":"10 Hz až 40 Hz","range":"10 mV až 10 V","cmc":"0,015 % + 5,5 µV"},{"name":"40 Hz až 1 kHz","range":"10 mV až 10 V","cmc":"0,010 % + 3,0 µV"},{"name":"1 kHz až 20 kHz","range":"10 mV až 10 V","cmc":"0,020 % + 4,0 µV"},{"name":"10 Hz až 40 Hz","range":"10 V až 100 V","cmc":"0,028 %"},{"name":"40 Hz až 70 Hz","range":"10 V až 100 V","cmc":"0,015 %"},{"name":"70 Hz až 20 kHz","range":"10 V až 100 V","cmc":"0,023 %"},{"name":"10 Hz až 40 Hz","range":"100 V až 600 V","cmc":"0,035 %"},{"name":"40 Hz až 70 Hz","range":"100 V až 600 V","cmc":"0,015 %"},{"name":"70 Hz až 1 kHz","range":"100 V až 600 V","cmc":"0,035 %"},{"name":"1 kHz až 20 kHz","range":"100 V až 600 V","cmc":"0,071 %"},{"name":"10 Hz až 1 kHz","range":"600 V až 700 V","cmc":"0,035 %"},{"name":"1 kHz až 20 kHz","range":"600 V až 700 V","cmc":"0,071 %"},{"name":"20 Hz až 1 kHz","range":"700 V až 1000 V","cmc":"0,04 %"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a standard multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a standard multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 40 Hz od 10 µV do 10 mV CMC 0,07 % + 3,5 µV\n40 Hz do 1 kHz od 10 µV do 10 mV CMC 0,04 % + 1,3 µV\n1 kHz do 20 kHz od 10 µV do 10 mV CMC 0,05 % + 1,3 µV\n10 Hz do 40 Hz od 10 mV do 10 V CMC 0,015 % + 5,5 µV\n40 Hz do 1 kHz od 10 mV do 10 V CMC 0,010 % + 3,0 µV\n1 kHz do 20 kHz od 10 mV do 10 V CMC 0,020 % + 4,0 µV\n10 Hz do 40 Hz od 10 V do 100 V CMC 0,028 %\n40 Hz do 70 Hz od 10 V do 100 V CMC 0,015 %\n70 Hz do 20 kHz od 10 V do 100 V CMC 0,023 %\n10 Hz do 40 Hz od 100 V do 600 V CMC 0,035 %\n40 Hz do 70 Hz od 100 V do 600 V CMC 0,015 %\n70 Hz do 1 kHz od 100 V do 600 V CMC 0,035 %\n1 kHz do 20 kHz od 100 V do 600 V CMC 0,071 %\n10 Hz do 1 kHz od 600 V do 700 V CMC 0,035 %\n1 kHz do 20 kHz od 600 V do 700 V CMC 0,071 %\n20 Hz do 1 kHz od 700 V do 1000 V CMC 0,04 %\nPorównanie z multimetrem wzorcowym","reference":"KP - 02, KP - 05, KP - 06","norm_bases":["KP - 02","KP - 05","KP - 06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / mierniki Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym 10 Hz do 40 Hz od 10 µV do 10 mV CMC 0,07 % + 3,5 µV 40 Hz do 1 kHz od 10 µV do 10 mV CMC 0,04 % + 1,3 µV 1 kHz do 20 kHz od 10 µV do 10 mV CMC 0,05 % + 1,3 µV 10 Hz do 40 Hz od 10 mV do 10 V CMC 0,015 % + 5,5 µV 40 Hz do 1 kHz od 10 mV do 10 V CMC 0,010 % + 3,0 µV 1 kHz do 20 kHz od 10 mV do 10 V CMC 0,020 % + 4,0 µV 10 Hz do 40 Hz od 10 V do 100 V CMC 0,028 % 40 Hz do 70 Hz od 10 V do 100 V CMC 0,015 % 70 Hz do 20 kHz od 10 V do 100 V CMC 0,023 % 10 Hz do 40 Hz od 100 V do 600 V CMC 0,035 % 40 Hz do 70 Hz od 100 V do 600 V CMC 0,015 % 70 Hz do 1 kHz od 100 V do 600 V CMC 0,035 % 1 kHz do 20 kHz od 100 V do 600 V CMC 0,071 % 10 Hz do 1 kHz od 600 V do 700 V CMC 0,035 % 1 kHz do 20 kHz od 600 V do 700 V CMC 0,071 % 20 Hz do 1 kHz od 700 V do 1000 V CMC 0,04 % Střídavé napětí / Měřidla Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 10 Hz až 40 Hz 10 µV až 10 mV CMC 0,07 % + 3,5 µV 40 Hz až 1 kHz 10 µV až 10 mV CMC 0,04 % + 1,3 µV 1 kHz až 20 kHz 10 µV až 10 mV CMC 0,05 % + 1,3 µV 10 Hz až 40 Hz 10 mV až 10 V CMC 0,015 % + 5,5 µV 40 Hz až 1 kHz 10 mV až 10 V CMC 0,010 % + 3,0 µV 1 kHz až 20 kHz 10 mV až 10 V CMC 0,020 % + 4,0 µV 10 Hz až 40 Hz 10 V až 100 V CMC 0,028 % 40 Hz až 70 Hz 10 V až 100 V CMC 0,015 % 70 Hz až 20 kHz 10 V až 100 V CMC 0,023 % 10 Hz až 40 Hz 100 V až 600 V CMC 0,035 % 40 Hz až 70 Hz 100 V až 600 V CMC 0,015 % 70 Hz až 1 kHz 100 V až 600 V CMC 0,035 % 1 kHz až 20 kHz 100 V až 600 V CMC 0,071 % 10 Hz až 1 kHz 600 V až 700 V CMC 0,035 % 1 kHz až 20 kHz 600 V až 700 V CMC 0,071 % 20 Hz až 1 kHz 700 V až 1000 V CMC 0,04 % KP - 02, KP - 05, KP - 06 Napiecie przemienne / mierniki Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym 10 Hz do 40 Hz od 10 µV do 10 mV CMC 0,07 % + 3,5 µV 40 Hz do 1 kHz od 10 µV do 10 mV CMC 0,04 % + 1,3 µV 1 kHz do 20 kHz od 10 µV do 10 mV CMC 0,05 % + 1,3 µV 10 Hz do 40 Hz od 10 mV do 10 V CMC 0,015 % + 5,5 µV 40 Hz do 1 kHz od 10 mV do 10 V CMC 0,010 % + 3,0 µV 1 kHz do 20 kHz od 10 mV do 10 V CMC 0,020 % + 4,0 µV 10 Hz do 40 Hz od 10 V do 100 V CMC 0,028 % 40 Hz do 70 Hz od 10 V do 100 V CMC 0,015 % 70 Hz do 20 kHz od 10 V do 100 V CMC 0,023 % 10 Hz do 40 Hz od 100 V do 600 V CMC 0,035 % 40 Hz do 70 Hz od 100 V do 600 V CMC 0,015 % 70 Hz do 1 kHz od 100 V do 600 V CMC 0,035 % 1 kHz do 20 kHz od 100 V do 600 V CMC 0,071 % 10 Hz do 1 kHz od 600 V do 700 V CMC 0,035 % 1 kHz do 20 kHz od 600 V do 700 V CMC 0,071 % 20 Hz do 1 kHz od 700 V do 1000 V CMC 0,04 % Stridave napeti / Meridla Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 10 Hz az 40 Hz 10 µV az 10 mV CMC 0,07 % + 3,5 µV 40 Hz az 1 kHz 10 µV az 10 mV CMC 0,04 % + 1,3 µV 1 kHz az 20 kHz 10 µV az 10 mV CMC 0,05 % + 1,3 µV 10 Hz az 40 Hz 10 mV az 10 V CMC 0,015 % + 5,5 µV 40 Hz az 1 kHz 10 mV az 10 V CMC 0,010 % + 3,0 µV 1 kHz az 20 kHz 10 mV az 10 V CMC 0,020 % + 4,0 µV 10 Hz az 40 Hz 10 V az 100 V CMC 0,028 % 40 Hz az 70 Hz 10 V az 100 V CMC 0,015 % 70 Hz az 20 kHz 10 V az 100 V CMC 0,023 % 10 Hz az 40 Hz 100 V az 600 V CMC 0,035 % 40 Hz az 70 Hz 100 V az 600 V CMC 0,015 % 70 Hz az 1 kHz 100 V az 600 V CMC 0,035 % 1 kHz az 20 kHz 100 V az 600 V CMC 0,071 % 10 Hz az 1 kHz 600 V az 700 V CMC 0,035 % 1 kHz az 20 kHz 600 V az 700 V CMC 0,071 % 20 Hz az 1 kHz 700 V az 1000 V CMC 0,04 % KP - 02, KP - 05, KP - 06","search_en":"AC voltage / Meters Calibration – electrical quantities Comparison with a standard multimeter 10 Hz to 40 Hz 10 µV to 10 mV CMC 0,07 % + 3,5 µV 40 Hz to 1 kHz 10 µV to 10 mV CMC 0,04 % + 1,3 µV 1 kHz to 20 kHz 10 µV to 10 mV CMC 0,05 % + 1,3 µV 10 Hz to 40 Hz 10 mV to 10 V CMC 0,015 % + 5,5 µV 40 Hz to 1 kHz 10 mV to 10 V CMC 0,010 % + 3,0 µV 1 kHz to 20 kHz 10 mV to 10 V CMC 0,020 % + 4,0 µV 10 Hz to 40 Hz 10 V to 100 V CMC 0,028 % 40 Hz to 70 Hz 10 V to 100 V CMC 0,015 % 70 Hz to 20 kHz 10 V to 100 V CMC 0,023 % 10 Hz to 40 Hz 100 V to 600 V CMC 0,035 % 40 Hz to 70 Hz 100 V to 600 V CMC 0,015 % 70 Hz to 1 kHz 100 V to 600 V CMC 0,035 % 1 kHz to 20 kHz 100 V to 600 V CMC 0,071 % 10 Hz to 1 kHz 600 V to 700 V CMC 0,035 % 1 kHz to 20 kHz 600 V to 700 V CMC 0,071 % 20 Hz to 1 kHz 700 V to 1000 V CMC 0,04 % KP - 02, KP - 05, KP - 06","search_zh":"交流电压 / 测量仪器 校准 – 电学量 与标准万用表比较 10 Hz 至 40 Hz 10 µV 至 10 mV CMC 0,07 % + 3,5 µV 40 Hz 至 1 kHz 10 µV 至 10 mV CMC 0,04 % + 1,3 µV 1 kHz 至 20 kHz 10 µV 至 10 mV CMC 0,05 % + 1,3 µV 10 Hz 至 40 Hz 10 mV 至 10 V CMC 0,015 % + 5,5 µV 40 Hz 至 1 kHz 10 mV 至 10 V CMC 0,010 % + 3,0 µV 1 kHz 至 20 kHz 10 mV 至 10 V CMC 0,020 % + 4,0 µV 10 Hz 至 40 Hz 10 V 至 100 V CMC 0,028 % 40 Hz 至 70 Hz 10 V 至 100 V CMC 0,015 % 70 Hz 至 20 kHz 10 V 至 100 V CMC 0,023 % 10 Hz 至 40 Hz 100 V 至 600 V CMC 0,035 % 40 Hz 至 70 Hz 100 V 至 600 V CMC 0,015 % 70 Hz 至 1 kHz 100 V 至 600 V CMC 0,035 % 1 kHz 至 20 kHz 100 V 至 600 V CMC 0,071 % 10 Hz 至 1 kHz 600 V 至 700 V CMC 0,035 % 1 kHz 至 20 kHz 600 V 至 700 V CMC 0,071 % 20 Hz 至 1 kHz 700 V 至 1000 V CMC 0,04 % KP - 02, KP - 05, KP - 06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b2a696839e8896cf8464f9ef","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / źródła","test_object_en":"AC voltage / Sources","test_object_zh":"交流电压 / 电源","test_object_cs":"Střídavé napětí / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 40 Hz","range":"od 10 µV do 10 mV","cmc":"0,07 % + 3,5 µV"},{"name":"40 Hz do 1 kHz","range":"od 10 µV do 10 mV","cmc":"0,04 % + 1,3 µV"},{"name":"1 kHz do 20 kHz","range":"od 10 µV do 10 mV","cmc":"0,05 % + 1,3 µV"},{"name":"10 Hz do 40 Hz","range":"od 10 mV do 10 V","cmc":"0,015 % + 5,5 µV"},{"name":"40 Hz do 1 kHz","range":"od 10 mV do 10 V","cmc":"0,010 % + 3,0 µV"},{"name":"1 kHz do 20 kHz","range":"od 10 mV do 10 V","cmc":"0,020 % + 4,0 µV"},{"name":"10 Hz do 40 Hz","range":"od 10 V do 100 V","cmc":"0,028 %"},{"name":"40 Hz do 70 Hz","range":"od 10 V do 100 V","cmc":"0,015 %"},{"name":"70 Hz do 20 kHz","range":"od 10 V do 100 V","cmc":"0,023 %"},{"name":"10 Hz do 40 Hz","range":"od 100 V do 600 V","cmc":"0,050 %"},{"name":"40 Hz do 70 Hz","range":"od 100 V do 600 V","cmc":"0,015 %"},{"name":"70 Hz do 1 kHz","range":"od 100 V do 600 V","cmc":"0,046 %"},{"name":"1 kHz do 20 kHz","range":"od 100 V do 600 V","cmc":"0,071 %"},{"name":"10 Hz do 1 kHz","range":"od 600 V do 700 V","cmc":"0,035 %"},{"name":"1 kHz do 20 kHz","range":"od 600 V do 700 V","cmc":"0,071 %"},{"name":"40 Hz do 1 kHz","range":"od 700 V do 1000 V","cmc":"0,2 %"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"10 µV to 10 mV","cmc":"0,07 % + 3,5 µV"},{"name":"40 Hz to 1 kHz","range":"10 µV to 10 mV","cmc":"0,04 % + 1,3 µV"},{"name":"1 kHz to 20 kHz","range":"10 µV to 10 mV","cmc":"0,05 % + 1,3 µV"},{"name":"10 Hz to 40 Hz","range":"10 mV to 10 V","cmc":"0,015 % + 5,5 µV"},{"name":"40 Hz to 1 kHz","range":"10 mV to 10 V","cmc":"0,010 % + 3,0 µV"},{"name":"1 kHz to 20 kHz","range":"10 mV to 10 V","cmc":"0,020 % + 4,0 µV"},{"name":"10 Hz to 40 Hz","range":"10 V to 100 V","cmc":"0,028 %"},{"name":"40 Hz to 70 Hz","range":"10 V to 100 V","cmc":"0,015 %"},{"name":"70 Hz to 20 kHz","range":"10 V to 100 V","cmc":"0,023 %"},{"name":"10 Hz to 40 Hz","range":"100 V to 600 V","cmc":"0,050 %"},{"name":"40 Hz to 70 Hz","range":"100 V to 600 V","cmc":"0,015 %"},{"name":"70 Hz to 1 kHz","range":"100 V to 600 V","cmc":"0,046 %"},{"name":"1 kHz to 20 kHz","range":"100 V to 600 V","cmc":"0,071 %"},{"name":"10 Hz to 1 kHz","range":"600 V to 700 V","cmc":"0,035 %"},{"name":"1 kHz to 20 kHz","range":"600 V to 700 V","cmc":"0,071 %"},{"name":"40 Hz to 1 kHz","range":"700 V to 1000 V","cmc":"0,2 %"}],"parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"10 µV 至 10 mV","cmc":"0,07 % + 3,5 µV"},{"name":"40 Hz 至 1 kHz","range":"10 µV 至 10 mV","cmc":"0,04 % + 1,3 µV"},{"name":"1 kHz 至 20 kHz","range":"10 µV 至 10 mV","cmc":"0,05 % + 1,3 µV"},{"name":"10 Hz 至 40 Hz","range":"10 mV 至 10 V","cmc":"0,015 % + 5,5 µV"},{"name":"40 Hz 至 1 kHz","range":"10 mV 至 10 V","cmc":"0,010 % + 3,0 µV"},{"name":"1 kHz 至 20 kHz","range":"10 mV 至 10 V","cmc":"0,020 % + 4,0 µV"},{"name":"10 Hz 至 40 Hz","range":"10 V 至 100 V","cmc":"0,028 %"},{"name":"40 Hz 至 70 Hz","range":"10 V 至 100 V","cmc":"0,015 %"},{"name":"70 Hz 至 20 kHz","range":"10 V 至 100 V","cmc":"0,023 %"},{"name":"10 Hz 至 40 Hz","range":"100 V 至 600 V","cmc":"0,050 %"},{"name":"40 Hz 至 70 Hz","range":"100 V 至 600 V","cmc":"0,015 %"},{"name":"70 Hz 至 1 kHz","range":"100 V 至 600 V","cmc":"0,046 %"},{"name":"1 kHz 至 20 kHz","range":"100 V 至 600 V","cmc":"0,071 %"},{"name":"10 Hz 至 1 kHz","range":"600 V 至 700 V","cmc":"0,035 %"},{"name":"1 kHz 至 20 kHz","range":"600 V 至 700 V","cmc":"0,071 %"},{"name":"40 Hz 至 1 kHz","range":"700 V 至 1000 V","cmc":"0,2 %"}],"parameters_cs":[{"name":"10 Hz až 40 Hz","range":"10 µV až 10 mV","cmc":"0,07 % + 3,5 µV"},{"name":"40 Hz až 1 kHz","range":"10 µV až 10 mV","cmc":"0,04 % + 1,3 µV"},{"name":"1 kHz až 20 kHz","range":"10 µV až 10 mV","cmc":"0,05 % + 1,3 µV"},{"name":"10 Hz až 40 Hz","range":"10 mV až 10 V","cmc":"0,015 % + 5,5 µV"},{"name":"40 Hz až 1 kHz","range":"10 mV až 10 V","cmc":"0,010 % + 3,0 µV"},{"name":"1 kHz až 20 kHz","range":"10 mV až 10 V","cmc":"0,020 % + 4,0 µV"},{"name":"10 Hz až 40 Hz","range":"10 V až 100 V","cmc":"0,028 %"},{"name":"40 Hz až 70 Hz","range":"10 V až 100 V","cmc":"0,015 %"},{"name":"70 Hz až 20 kHz","range":"10 V až 100 V","cmc":"0,023 %"},{"name":"10 Hz až 40 Hz","range":"100 V až 600 V","cmc":"0,050 %"},{"name":"40 Hz až 70 Hz","range":"100 V až 600 V","cmc":"0,015 %"},{"name":"70 Hz až 1 kHz","range":"100 V až 600 V","cmc":"0,046 %"},{"name":"1 kHz až 20 kHz","range":"100 V až 600 V","cmc":"0,071 %"},{"name":"10 Hz až 1 kHz","range":"600 V až 700 V","cmc":"0,035 %"},{"name":"1 kHz až 20 kHz","range":"600 V až 700 V","cmc":"0,071 %"},{"name":"40 Hz až 1 kHz","range":"700 V až 1000 V","cmc":"0,2 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement with a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement with a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 40 Hz od 10 µV do 10 mV CMC 0,07 % + 3,5 µV\n40 Hz do 1 kHz od 10 µV do 10 mV CMC 0,04 % + 1,3 µV\n1 kHz do 20 kHz od 10 µV do 10 mV CMC 0,05 % + 1,3 µV\n10 Hz do 40 Hz od 10 mV do 10 V CMC 0,015 % + 5,5 µV\n40 Hz do 1 kHz od 10 mV do 10 V CMC 0,010 % + 3,0 µV\n1 kHz do 20 kHz od 10 mV do 10 V CMC 0,020 % + 4,0 µV\n10 Hz do 40 Hz od 10 V do 100 V CMC 0,028 %\n40 Hz do 70 Hz od 10 V do 100 V CMC 0,015 %\n70 Hz do 20 kHz od 10 V do 100 V CMC 0,023 %\n10 Hz do 40 Hz od 100 V do 600 V CMC 0,050 %\n40 Hz do 70 Hz od 100 V do 600 V CMC 0,015 %\n70 Hz do 1 kHz od 100 V do 600 V CMC 0,046 %\n1 kHz do 20 kHz od 100 V do 600 V CMC 0,071 %\n10 Hz do 1 kHz od 600 V do 700 V CMC 0,035 %\n1 kHz do 20 kHz od 600 V do 700 V CMC 0,071 %\n40 Hz do 1 kHz od 700 V do 1000 V CMC 0,2 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"KP - 08","norm_bases":["KP - 08"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 10 Hz do 40 Hz od 10 µV do 10 mV CMC 0,07 % + 3,5 µV 40 Hz do 1 kHz od 10 µV do 10 mV CMC 0,04 % + 1,3 µV 1 kHz do 20 kHz od 10 µV do 10 mV CMC 0,05 % + 1,3 µV 10 Hz do 40 Hz od 10 mV do 10 V CMC 0,015 % + 5,5 µV 40 Hz do 1 kHz od 10 mV do 10 V CMC 0,010 % + 3,0 µV 1 kHz do 20 kHz od 10 mV do 10 V CMC 0,020 % + 4,0 µV 10 Hz do 40 Hz od 10 V do 100 V CMC 0,028 % 40 Hz do 70 Hz od 10 V do 100 V CMC 0,015 % 70 Hz do 20 kHz od 10 V do 100 V CMC 0,023 % 10 Hz do 40 Hz od 100 V do 600 V CMC 0,050 % 40 Hz do 70 Hz od 100 V do 600 V CMC 0,015 % 70 Hz do 1 kHz od 100 V do 600 V CMC 0,046 % 1 kHz do 20 kHz od 100 V do 600 V CMC 0,071 % 10 Hz do 1 kHz od 600 V do 700 V CMC 0,035 % 1 kHz do 20 kHz od 600 V do 700 V CMC 0,071 % 40 Hz do 1 kHz od 700 V do 1000 V CMC 0,2 % Střídavé napětí / Zdroje Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 10 Hz až 40 Hz 10 µV až 10 mV CMC 0,07 % + 3,5 µV 40 Hz až 1 kHz 10 µV až 10 mV CMC 0,04 % + 1,3 µV 1 kHz až 20 kHz 10 µV až 10 mV CMC 0,05 % + 1,3 µV 10 Hz až 40 Hz 10 mV až 10 V CMC 0,015 % + 5,5 µV 40 Hz až 1 kHz 10 mV až 10 V CMC 0,010 % + 3,0 µV 1 kHz až 20 kHz 10 mV až 10 V CMC 0,020 % + 4,0 µV 10 Hz až 40 Hz 10 V až 100 V CMC 0,028 % 40 Hz až 70 Hz 10 V až 100 V CMC 0,015 % 70 Hz až 20 kHz 10 V až 100 V CMC 0,023 % 10 Hz až 40 Hz 100 V až 600 V CMC 0,050 % 40 Hz až 70 Hz 100 V až 600 V CMC 0,015 % 70 Hz až 1 kHz 100 V až 600 V CMC 0,046 % 1 kHz až 20 kHz 100 V až 600 V CMC 0,071 % 10 Hz až 1 kHz 600 V až 700 V CMC 0,035 % 1 kHz až 20 kHz 600 V až 700 V CMC 0,071 % 40 Hz až 1 kHz 700 V až 1000 V CMC 0,2 % KP - 08 Napiecie przemienne / zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 10 Hz do 40 Hz od 10 µV do 10 mV CMC 0,07 % + 3,5 µV 40 Hz do 1 kHz od 10 µV do 10 mV CMC 0,04 % + 1,3 µV 1 kHz do 20 kHz od 10 µV do 10 mV CMC 0,05 % + 1,3 µV 10 Hz do 40 Hz od 10 mV do 10 V CMC 0,015 % + 5,5 µV 40 Hz do 1 kHz od 10 mV do 10 V CMC 0,010 % + 3,0 µV 1 kHz do 20 kHz od 10 mV do 10 V CMC 0,020 % + 4,0 µV 10 Hz do 40 Hz od 10 V do 100 V CMC 0,028 % 40 Hz do 70 Hz od 10 V do 100 V CMC 0,015 % 70 Hz do 20 kHz od 10 V do 100 V CMC 0,023 % 10 Hz do 40 Hz od 100 V do 600 V CMC 0,050 % 40 Hz do 70 Hz od 100 V do 600 V CMC 0,015 % 70 Hz do 1 kHz od 100 V do 600 V CMC 0,046 % 1 kHz do 20 kHz od 100 V do 600 V CMC 0,071 % 10 Hz do 1 kHz od 600 V do 700 V CMC 0,035 % 1 kHz do 20 kHz od 600 V do 700 V CMC 0,071 % 40 Hz do 1 kHz od 700 V do 1000 V CMC 0,2 % Stridave napeti / Zdroje Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 10 Hz az 40 Hz 10 µV az 10 mV CMC 0,07 % + 3,5 µV 40 Hz az 1 kHz 10 µV az 10 mV CMC 0,04 % + 1,3 µV 1 kHz az 20 kHz 10 µV az 10 mV CMC 0,05 % + 1,3 µV 10 Hz az 40 Hz 10 mV az 10 V CMC 0,015 % + 5,5 µV 40 Hz az 1 kHz 10 mV az 10 V CMC 0,010 % + 3,0 µV 1 kHz az 20 kHz 10 mV az 10 V CMC 0,020 % + 4,0 µV 10 Hz az 40 Hz 10 V az 100 V CMC 0,028 % 40 Hz az 70 Hz 10 V az 100 V CMC 0,015 % 70 Hz az 20 kHz 10 V az 100 V CMC 0,023 % 10 Hz az 40 Hz 100 V az 600 V CMC 0,050 % 40 Hz az 70 Hz 100 V az 600 V CMC 0,015 % 70 Hz az 1 kHz 100 V az 600 V CMC 0,046 % 1 kHz az 20 kHz 100 V az 600 V CMC 0,071 % 10 Hz az 1 kHz 600 V az 700 V CMC 0,035 % 1 kHz az 20 kHz 600 V az 700 V CMC 0,071 % 40 Hz az 1 kHz 700 V az 1000 V CMC 0,2 % KP - 08","search_en":"AC voltage / Sources Calibration – electrical quantities Direct measurement with a standard multimeter 10 Hz to 40 Hz 10 µV to 10 mV CMC 0,07 % + 3,5 µV 40 Hz to 1 kHz 10 µV to 10 mV CMC 0,04 % + 1,3 µV 1 kHz to 20 kHz 10 µV to 10 mV CMC 0,05 % + 1,3 µV 10 Hz to 40 Hz 10 mV to 10 V CMC 0,015 % + 5,5 µV 40 Hz to 1 kHz 10 mV to 10 V CMC 0,010 % + 3,0 µV 1 kHz to 20 kHz 10 mV to 10 V CMC 0,020 % + 4,0 µV 10 Hz to 40 Hz 10 V to 100 V CMC 0,028 % 40 Hz to 70 Hz 10 V to 100 V CMC 0,015 % 70 Hz to 20 kHz 10 V to 100 V CMC 0,023 % 10 Hz to 40 Hz 100 V to 600 V CMC 0,050 % 40 Hz to 70 Hz 100 V to 600 V CMC 0,015 % 70 Hz to 1 kHz 100 V to 600 V CMC 0,046 % 1 kHz to 20 kHz 100 V to 600 V CMC 0,071 % 10 Hz to 1 kHz 600 V to 700 V CMC 0,035 % 1 kHz to 20 kHz 600 V to 700 V CMC 0,071 % 40 Hz to 1 kHz 700 V to 1000 V CMC 0,2 % KP - 08","search_zh":"交流电压 / 电源 校准 – 电学量 用标准万用表直接测量 10 Hz 至 40 Hz 10 µV 至 10 mV CMC 0,07 % + 3,5 µV 40 Hz 至 1 kHz 10 µV 至 10 mV CMC 0,04 % + 1,3 µV 1 kHz 至 20 kHz 10 µV 至 10 mV CMC 0,05 % + 1,3 µV 10 Hz 至 40 Hz 10 mV 至 10 V CMC 0,015 % + 5,5 µV 40 Hz 至 1 kHz 10 mV 至 10 V CMC 0,010 % + 3,0 µV 1 kHz 至 20 kHz 10 mV 至 10 V CMC 0,020 % + 4,0 µV 10 Hz 至 40 Hz 10 V 至 100 V CMC 0,028 % 40 Hz 至 70 Hz 10 V 至 100 V CMC 0,015 % 70 Hz 至 20 kHz 10 V 至 100 V CMC 0,023 % 10 Hz 至 40 Hz 100 V 至 600 V CMC 0,050 % 40 Hz 至 70 Hz 100 V 至 600 V CMC 0,015 % 70 Hz 至 1 kHz 100 V 至 600 V CMC 0,046 % 1 kHz 至 20 kHz 100 V 至 600 V CMC 0,071 % 10 Hz 至 1 kHz 600 V 至 700 V CMC 0,035 % 1 kHz 至 20 kHz 600 V 至 700 V CMC 0,071 % 40 Hz 至 1 kHz 700 V 至 1000 V CMC 0,2 % KP - 08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"901c0da80b0f185b4ca1d6b0","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / źródła","test_object_en":"AC voltage / Sources","test_object_zh":"交流电压 / 电源","test_object_cs":"Střídavé napětí / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 55 Hz","range":"od 1 kV do 40 kV","cmc":"0,6 %"}],"parameters_en":[{"name":"45 Hz to 55 Hz","range":"1 kV to 40 kV","cmc":"0,6 %"}],"parameters_zh":[{"name":"45 Hz 至 55 Hz","range":"1 kV 至 40 kV","cmc":"0,6 %"}],"parameters_cs":[{"name":"45 Hz až 55 Hz","range":"1 kV až 40 kV","cmc":"0,6 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym i dzielnikiem napięcia","technique_en":"Direct measurement with a standard multimeter and a voltage divider","technique_zh":"用标准万用表和分压器直接测量","technique_cs":"Přímé měření etalonovým multimetrem a napěťovým děličem","techniques":["Pomiar bezpośredni multimetrem wzorcowym i dzielnikiem napięcia"],"techniques_en":["Direct measurement with a standard multimeter and a voltage divider"],"techniques_zh":["用标准万用表和分压器直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem a napěťovým děličem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n45 Hz do 55 Hz od 1 kV do 40 kV CMC 0,6 %\nPomiar bezpośredni multimetrem wzorcowym i dzielnikiem napięcia","reference":"KP - 08","norm_bases":["KP - 08"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym i dzielnikiem napięcia 45 Hz do 55 Hz od 1 kV do 40 kV CMC 0,6 % Střídavé napětí / Zdroje Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem a napěťovým děličem 45 Hz až 55 Hz 1 kV až 40 kV CMC 0,6 % KP - 08 Napiecie przemienne / zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym i dzielnikiem napiecia 45 Hz do 55 Hz od 1 kV do 40 kV CMC 0,6 % Stridave napeti / Zdroje Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem a napetovym delicem 45 Hz az 55 Hz 1 kV az 40 kV CMC 0,6 % KP - 08","search_en":"AC voltage / Sources Calibration – electrical quantities Direct measurement with a standard multimeter and a voltage divider 45 Hz to 55 Hz 1 kV to 40 kV CMC 0,6 % KP - 08","search_zh":"交流电压 / 电源 校准 – 电学量 用标准万用表和分压器直接测量 45 Hz 至 55 Hz 1 kV 至 40 kV CMC 0,6 % KP - 08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7e6602dabf41ab056aafa9bd","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / mierniki","test_object_en":"DC current / Meters","test_object_zh":"直流电流 / 测量仪器","test_object_cs":"Stejnosměrný proud / Měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 1 µA","cmc":"0,05 % + 0,1 nA"},{"name":"","range":"od 1 µA do 200 µA","cmc":"0,0043 %"},{"name":"","range":"od 200 µA do 100 mA","cmc":"0,0047 %"},{"name":"","range":"100 mA","cmc":"0,0020 %"},{"name":"","range":"od 100 mA do 1 A","cmc":"0,0035 %"},{"name":"","range":"1 A","cmc":"0,0020 %"},{"name":"","range":"od 1 A do 30 A","cmc":"0,0050 %"},{"name":"","range":"od 30 A do 90 A","cmc":"0,015 %"}],"parameters_en":[{"name":"","range":"0 µA to 1 µA","cmc":"0,05 % + 0,1 nA"},{"name":"","range":"1 µA to 200 µA","cmc":"0,0043 %"},{"name":"","range":"200 µA to 100 mA","cmc":"0,0047 %"},{"name":"","range":"100 mA","cmc":"0,0020 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,0035 %"},{"name":"","range":"1 A","cmc":"0,0020 %"},{"name":"","range":"1 A to 30 A","cmc":"0,0050 %"},{"name":"","range":"30 A to 90 A","cmc":"0,015 %"}],"parameters_zh":[{"name":"","range":"0 µA 至 1 µA","cmc":"0,05 % + 0,1 nA"},{"name":"","range":"1 µA 至 200 µA","cmc":"0,0043 %"},{"name":"","range":"200 µA 至 100 mA","cmc":"0,0047 %"},{"name":"","range":"100 mA","cmc":"0,0020 %"},{"name":"","range":"100 mA 至 1 A","cmc":"0,0035 %"},{"name":"","range":"1 A","cmc":"0,0020 %"},{"name":"","range":"1 A 至 30 A","cmc":"0,0050 %"},{"name":"","range":"30 A 至 90 A","cmc":"0,015 %"}],"parameters_cs":[{"name":"","range":"0 µA až 1 µA","cmc":"0,05 % + 0,1 nA"},{"name":"","range":"1 µA až 200 µA","cmc":"0,0043 %"},{"name":"","range":"200 µA až 100 mA","cmc":"0,0047 %"},{"name":"","range":"100 mA","cmc":"0,0020 %"},{"name":"","range":"100 mA až 1 A","cmc":"0,0035 %"},{"name":"","range":"1 A","cmc":"0,0020 %"},{"name":"","range":"1 A až 30 A","cmc":"0,0050 %"},{"name":"","range":"30 A až 90 A","cmc":"0,015 %"}],"technique":"Porównanie z multimetrem wzorcowym i bocznikiem","technique_en":"Comparison with a standard multimeter and a shunt","technique_zh":"与标准万用表和分流器比较","technique_cs":"Porovnání s etalonovým multimetrem a bočníkem","techniques":["Porównanie z multimetrem wzorcowym i bocznikiem"],"techniques_en":["Comparison with a standard multimeter and a shunt"],"techniques_zh":["与标准万用表和分流器比较"],"techniques_cs":["Porovnání s etalonovým multimetrem a bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 1 µA CMC 0,05 % + 0,1 nA\nod 1 µA do 200 µA CMC 0,0043 %\nod 200 µA do 100 mA CMC 0,0047 %\n100 mA CMC 0,0020 %\nod 100 mA do 1 A CMC 0,0035 %\n1 A CMC 0,0020 %\nod 1 A do 30 A CMC 0,0050 %\nod 30 A do 90 A CMC 0,015 %\nPorównanie z multimetrem wzorcowym i bocznikiem","reference":"KP - 03, KP - 05, KP - 06","norm_bases":["KP - 03","KP - 05","KP - 06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym i bocznikiem od 0 µA do 1 µA CMC 0,05 % + 0,1 nA od 1 µA do 200 µA CMC 0,0043 % od 200 µA do 100 mA CMC 0,0047 % 100 mA CMC 0,0020 % od 100 mA do 1 A CMC 0,0035 % 1 A CMC 0,0020 % od 1 A do 30 A CMC 0,0050 % od 30 A do 90 A CMC 0,015 % Stejnosměrný proud / Měřidla Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem a bočníkem 0 µA až 1 µA CMC 0,05 % + 0,1 nA 1 µA až 200 µA CMC 0,0043 % 200 µA až 100 mA CMC 0,0047 % 100 mA CMC 0,0020 % 100 mA až 1 A CMC 0,0035 % 1 A CMC 0,0020 % 1 A až 30 A CMC 0,0050 % 30 A až 90 A CMC 0,015 % KP - 03, KP - 05, KP - 06 Prad staly / mierniki Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym i bocznikiem od 0 µA do 1 µA CMC 0,05 % + 0,1 nA od 1 µA do 200 µA CMC 0,0043 % od 200 µA do 100 mA CMC 0,0047 % 100 mA CMC 0,0020 % od 100 mA do 1 A CMC 0,0035 % 1 A CMC 0,0020 % od 1 A do 30 A CMC 0,0050 % od 30 A do 90 A CMC 0,015 % Stejnosmerny proud / Meridla Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem a bocnikem 0 µA az 1 µA CMC 0,05 % + 0,1 nA 1 µA az 200 µA CMC 0,0043 % 200 µA az 100 mA CMC 0,0047 % 100 mA CMC 0,0020 % 100 mA az 1 A CMC 0,0035 % 1 A CMC 0,0020 % 1 A az 30 A CMC 0,0050 % 30 A az 90 A CMC 0,015 % KP - 03, KP - 05, KP - 06","search_en":"DC current / Meters Calibration – electrical quantities Comparison with a standard multimeter and a shunt 0 µA to 1 µA CMC 0,05 % + 0,1 nA 1 µA to 200 µA CMC 0,0043 % 200 µA to 100 mA CMC 0,0047 % 100 mA CMC 0,0020 % 100 mA to 1 A CMC 0,0035 % 1 A CMC 0,0020 % 1 A to 30 A CMC 0,0050 % 30 A to 90 A CMC 0,015 % KP - 03, KP - 05, KP - 06","search_zh":"直流电流 / 测量仪器 校准 – 电学量 与标准万用表和分流器比较 0 µA 至 1 µA CMC 0,05 % + 0,1 nA 1 µA 至 200 µA CMC 0,0043 % 200 µA 至 100 mA CMC 0,0047 % 100 mA CMC 0,0020 % 100 mA 至 1 A CMC 0,0035 % 1 A CMC 0,0020 % 1 A 至 30 A CMC 0,0050 % 30 A 至 90 A CMC 0,015 % KP - 03, KP - 05, KP - 06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"efe1ec5e6258044a35d38996","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / mierniki cęgowe","test_object_en":"DC current / Clamp meters","test_object_zh":"直流电流 / 钳形表","test_object_cs":"Stejnosměrný proud / Klešťová měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,5 A do 3000 A","cmc":"0,6 %"}],"parameters_en":[{"name":"","range":"0,5 A to 3000 A","cmc":"0,6 %"}],"parameters_zh":[{"name":"","range":"0,5 A 至 3000 A","cmc":"0,6 %"}],"parameters_cs":[{"name":"","range":"0,5 A až 3000 A","cmc":"0,6 %"}],"technique":"Pomiar pośredni kalibratorem z cewką prądową","technique_en":"Indirect measurement with a calibrator with a current coil","technique_zh":"用带电流线圈的校准器间接测量","technique_cs":"Nepřímé měření kalibrátoru s proudovou cívkou","techniques":["Pomiar pośredni kalibratorem z cewką prądową"],"techniques_en":["Indirect measurement with a calibrator with a current coil"],"techniques_zh":["用带电流线圈的校准器间接测量"],"techniques_cs":["Nepřímé měření kalibrátoru s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 0,5 A do 3000 A CMC 0,6 %\nPomiar pośredni kalibratorem z cewką prądową","reference":"KP - 07","norm_bases":["KP - 07"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki cęgowe Wzorcowanie – wielkości elektryczne Pomiar pośredni kalibratorem z cewką prądową od 0,5 A do 3000 A CMC 0,6 % Stejnosměrný proud / Klešťová měřidla Kalibrace – elektrické veličiny Nepřímé měření kalibrátoru s proudovou cívkou 0,5 A až 3000 A CMC 0,6 % KP - 07 Prad staly / mierniki cegowe Wzorcowanie – wielkosci elektryczne Pomiar posredni kalibratorem z cewka pradowa od 0,5 A do 3000 A CMC 0,6 % Stejnosmerny proud / Klestova meridla Kalibrace – elektricke veliciny Neprime mereni kalibratoru s proudovou civkou 0,5 A az 3000 A CMC 0,6 % KP - 07","search_en":"DC current / Clamp meters Calibration – electrical quantities Indirect measurement with a calibrator with a current coil 0,5 A to 3000 A CMC 0,6 % KP - 07","search_zh":"直流电流 / 钳形表 校准 – 电学量 用带电流线圈的校准器间接测量 0,5 A 至 3000 A CMC 0,6 % KP - 07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3daa10c7ffaab6155ac26e1d","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła","test_object_en":"DC current / Sources","test_object_zh":"直流电流 / 电流源","test_object_cs":"Stejnosměrný proud / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 1 µA","cmc":"0,05 % + 0,1 nA"},{"name":"","range":"od 1 µA do 10 µA","cmc":"0,0043 %"},{"name":"","range":"od 10 µA do 100 µA","cmc":"0,0036 %"},{"name":"","range":"od 100 µA do 10 mA","cmc":"0,0030 %"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,0047 %"},{"name":"","range":"od 100 mA do 1 A","cmc":"0,0035 %"},{"name":"","range":"od 1 A do 10 A","cmc":"0,0050 %"}],"parameters_en":[{"name":"","range":"0 µA to 1 µA","cmc":"0,05 % + 0,1 nA"},{"name":"","range":"1 µA to 10 µA","cmc":"0,0043 %"},{"name":"","range":"10 µA to 100 µA","cmc":"0,0036 %"},{"name":"","range":"100 µA to 10 mA","cmc":"0,0030 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,0047 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,0035 %"},{"name":"","range":"1 A to 10 A","cmc":"0,0050 %"}],"parameters_zh":[{"name":"","range":"0 µA 至 1 µA","cmc":"0,05 % + 0,1 nA"},{"name":"","range":"1 µA 至 10 µA","cmc":"0,0043 %"},{"name":"","range":"10 µA 至 100 µA","cmc":"0,0036 %"},{"name":"","range":"100 µA 至 10 mA","cmc":"0,0030 %"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,0047 %"},{"name":"","range":"100 mA 至 1 A","cmc":"0,0035 %"},{"name":"","range":"1 A 至 10 A","cmc":"0,0050 %"}],"parameters_cs":[{"name":"","range":"0 µA až 1 µA","cmc":"0,05 % + 0,1 nA"},{"name":"","range":"1 µA až 10 µA","cmc":"0,0043 %"},{"name":"","range":"10 µA až 100 µA","cmc":"0,0036 %"},{"name":"","range":"100 µA až 10 mA","cmc":"0,0030 %"},{"name":"","range":"10 mA až 100 mA","cmc":"0,0047 %"},{"name":"","range":"100 mA až 1 A","cmc":"0,0035 %"},{"name":"","range":"1 A až 10 A","cmc":"0,0050 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement with a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement with a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 1 µA CMC 0,05 % + 0,1 nA\nod 1 µA do 10 µA CMC 0,0043 %\nod 10 µA do 100 µA CMC 0,0036 %\nod 100 µA do 10 mA CMC 0,0030 %\nod 10 mA do 100 mA CMC 0,0047 %\nod 100 mA do 1 A CMC 0,0035 %\nod 1 A do 10 A CMC 0,0050 %\nPomiar bezpośredni multimetrem","reference":"KP - 08","norm_bases":["KP - 08"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 µA do 1 µA CMC 0,05 % + 0,1 nA od 1 µA do 10 µA CMC 0,0043 % od 10 µA do 100 µA CMC 0,0036 % od 100 µA do 10 mA CMC 0,0030 % od 10 mA do 100 mA CMC 0,0047 % od 100 mA do 1 A CMC 0,0035 % od 1 A do 10 A CMC 0,0050 % Stejnosměrný proud / Zdroje Kalibrace – elektrické veličiny Přímé měření multimetrem 0 µA až 1 µA CMC 0,05 % + 0,1 nA 1 µA až 10 µA CMC 0,0043 % 10 µA až 100 µA CMC 0,0036 % 100 µA až 10 mA CMC 0,0030 % 10 mA až 100 mA CMC 0,0047 % 100 mA až 1 A CMC 0,0035 % 1 A až 10 A CMC 0,0050 % KP - 08 Prad staly / zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 µA do 1 µA CMC 0,05 % + 0,1 nA od 1 µA do 10 µA CMC 0,0043 % od 10 µA do 100 µA CMC 0,0036 % od 100 µA do 10 mA CMC 0,0030 % od 10 mA do 100 mA CMC 0,0047 % od 100 mA do 1 A CMC 0,0035 % od 1 A do 10 A CMC 0,0050 % Stejnosmerny proud / Zdroje Kalibrace – elektricke veliciny Prime mereni multimetrem 0 µA az 1 µA CMC 0,05 % + 0,1 nA 1 µA az 10 µA CMC 0,0043 % 10 µA az 100 µA CMC 0,0036 % 100 µA az 10 mA CMC 0,0030 % 10 mA az 100 mA CMC 0,0047 % 100 mA az 1 A CMC 0,0035 % 1 A az 10 A CMC 0,0050 % KP - 08","search_en":"DC current / Sources Calibration – electrical quantities Direct measurement with a multimeter 0 µA to 1 µA CMC 0,05 % + 0,1 nA 1 µA to 10 µA CMC 0,0043 % 10 µA to 100 µA CMC 0,0036 % 100 µA to 10 mA CMC 0,0030 % 10 mA to 100 mA CMC 0,0047 % 100 mA to 1 A CMC 0,0035 % 1 A to 10 A CMC 0,0050 % KP - 08","search_zh":"直流电流 / 电流源 校准 – 电学量 用万用表直接测量 0 µA 至 1 µA CMC 0,05 % + 0,1 nA 1 µA 至 10 µA CMC 0,0043 % 10 µA 至 100 µA CMC 0,0036 % 100 µA 至 10 mA CMC 0,0030 % 10 mA 至 100 mA CMC 0,0047 % 100 mA 至 1 A CMC 0,0035 % 1 A 至 10 A CMC 0,0050 % KP - 08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ac0e8780125aef4cf3161221","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła","test_object_en":"DC current / Sources","test_object_zh":"直流电流 / 电流源","test_object_cs":"Stejnosměrný proud / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 A do 200 A","cmc":"0,015 %"}],"parameters_en":[{"name":"","range":"10 A to 200 A","cmc":"0,015 %"}],"parameters_zh":[{"name":"","range":"10 A 至 200 A","cmc":"0,015 %"}],"parameters_cs":[{"name":"","range":"10 A až 200 A","cmc":"0,015 %"}],"technique":"Pomiar multimetrem i bocznikiem","technique_en":"Measurement with a multimeter and a shunt","technique_zh":"用万用表和分流器测量","technique_cs":"Měření multimetrem a bočníkem","techniques":["Pomiar multimetrem i bocznikiem"],"techniques_en":["Measurement with a multimeter and a shunt"],"techniques_zh":["用万用表和分流器测量"],"techniques_cs":["Měření multimetrem a bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 10 A do 200 A CMC 0,015 %\nPomiar multimetrem i bocznikiem","reference":"KP - 08","norm_bases":["KP - 08"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła Wzorcowanie – wielkości elektryczne Pomiar multimetrem i bocznikiem od 10 A do 200 A CMC 0,015 % Stejnosměrný proud / Zdroje Kalibrace – elektrické veličiny Měření multimetrem a bočníkem 10 A až 200 A CMC 0,015 % KP - 08 Prad staly / zrodla Wzorcowanie – wielkosci elektryczne Pomiar multimetrem i bocznikiem od 10 A do 200 A CMC 0,015 % Stejnosmerny proud / Zdroje Kalibrace – elektricke veliciny Mereni multimetrem a bocnikem 10 A az 200 A CMC 0,015 % KP - 08","search_en":"DC current / Sources Calibration – electrical quantities Measurement with a multimeter and a shunt 10 A to 200 A CMC 0,015 % KP - 08","search_zh":"直流电流 / 电流源 校准 – 电学量 用万用表和分流器测量 10 A 至 200 A CMC 0,015 % KP - 08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"292f41846aa869b661fa1038","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / mierniki","test_object_en":"AC current / Meters","test_object_zh":"交流电流 / 测量仪器","test_object_cs":"Střídavý proud / Měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 100 Hz","range":"od 0,1 µA do 1 µA","cmc":"0,2 %"}],"parameters_en":[{"name":"20 Hz to 100 Hz","range":"0,1 µA to 1 µA","cmc":"0,2 %"}],"parameters_zh":[{"name":"20 Hz 至 100 Hz","range":"0,1 µA 至 1 µA","cmc":"0,2 %"}],"parameters_cs":[{"name":"20 Hz až 100 Hz","range":"0,1 µA až 1 µA","cmc":"0,2 %"}],"technique":"Generowanie pośrednie za pomocą kalibratora napięcia i wzorca rezystancji","technique_en":"Indirect generation using a voltage calibrator and a resistance standard","technique_zh":"借助电压校准器和电阻标准器间接产生","technique_cs":"Nepřímé generování pomocí kalibrátoru napětí a etalonu odporu","techniques":["Generowanie pośrednie za pomocą kalibratora napięcia i wzorca rezystancji"],"techniques_en":["Indirect generation using a voltage calibrator and a resistance standard"],"techniques_zh":["借助电压校准器和电阻标准器间接产生"],"techniques_cs":["Nepřímé generování pomocí kalibrátoru napětí a etalonu odporu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n20 Hz do 100 Hz od 0,1 µA do 1 µA CMC 0,2 %\nGenerowanie pośrednie za pomocą kalibratora napięcia i wzorca rezystancji","reference":"KP - 04, KP - 05, KP - 06","norm_bases":["KP - 04","KP - 05","KP - 06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki Wzorcowanie – wielkości elektryczne Generowanie pośrednie za pomocą kalibratora napięcia i wzorca rezystancji 20 Hz do 100 Hz od 0,1 µA do 1 µA CMC 0,2 % Střídavý proud / Měřidla Kalibrace – elektrické veličiny Nepřímé generování pomocí kalibrátoru napětí a etalonu odporu 20 Hz až 100 Hz 0,1 µA až 1 µA CMC 0,2 % KP - 04, KP - 05, KP - 06 Prad przemienny / mierniki Wzorcowanie – wielkosci elektryczne Generowanie posrednie za pomoca kalibratora napiecia i wzorca rezystancji 20 Hz do 100 Hz od 0,1 µA do 1 µA CMC 0,2 % Stridavy proud / Meridla Kalibrace – elektricke veliciny Neprime generovani pomoci kalibratoru napeti a etalonu odporu 20 Hz az 100 Hz 0,1 µA az 1 µA CMC 0,2 % KP - 04, KP - 05, KP - 06","search_en":"AC current / Meters Calibration – electrical quantities Indirect generation using a voltage calibrator and a resistance standard 20 Hz to 100 Hz 0,1 µA to 1 µA CMC 0,2 % KP - 04, KP - 05, KP - 06","search_zh":"交流电流 / 测量仪器 校准 – 电学量 借助电压校准器和电阻标准器间接产生 20 Hz 至 100 Hz 0,1 µA 至 1 µA CMC 0,2 % KP - 04, KP - 05, KP - 06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ae972a5bea248bc311e2bb9","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / mierniki","test_object_en":"AC current / Meters","test_object_zh":"交流电流 / 测量仪器","test_object_cs":"Střídavý proud / Měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 1 µA do 100 µA","cmc":"0,08 %"},{"name":"1 kHz do 5 kHz","range":"od 1 µA do 100 µA","cmc":"0,09 %"},{"name":"20 Hz do 100 Hz","range":"od 100 µA do 10 mA","cmc":"0,08 %"},{"name":"100 Hz do 5 kHz","range":"od 100 µA do 10 mA","cmc":"0,05 %"},{"name":"40 Hz do 70 Hz","range":"od 10 mA do 100 mA","cmc":"0,02 %"},{"name":"70 Hz do 5 kHz","range":"od 10 mA do 100 mA","cmc":"0,05 %"},{"name":"40 Hz do 70 Hz","range":"od 100 mA do 1 A","cmc":"0,015 %"},{"name":"70 Hz do 5 kHz","range":"od 100 mA do 1 A","cmc":"0,050 %"},{"name":"40 Hz do 70 Hz","range":"od 1 A do 90 A","cmc":"0,015 %"},{"name":"70 Hz do 400 Hz","range":"od 1 A do 30 A","cmc":"0,07 %"},{"name":"70 Hz do 400 Hz","range":"od 30 A do 90 A","cmc":"0,14 %"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"1 µA to 100 µA","cmc":"0,08 %"},{"name":"1 kHz to 5 kHz","range":"1 µA to 100 µA","cmc":"0,09 %"},{"name":"20 Hz to 100 Hz","range":"100 µA to 10 mA","cmc":"0,08 %"},{"name":"100 Hz to 5 kHz","range":"100 µA to 10 mA","cmc":"0,05 %"},{"name":"40 Hz to 70 Hz","range":"10 mA to 100 mA","cmc":"0,02 %"},{"name":"70 Hz to 5 kHz","range":"10 mA to 100 mA","cmc":"0,05 %"},{"name":"40 Hz to 70 Hz","range":"100 mA to 1 A","cmc":"0,015 %"},{"name":"70 Hz to 5 kHz","range":"100 mA to 1 A","cmc":"0,050 %"},{"name":"40 Hz to 70 Hz","range":"1 A to 90 A","cmc":"0,015 %"},{"name":"70 Hz to 400 Hz","range":"1 A to 30 A","cmc":"0,07 %"},{"name":"70 Hz to 400 Hz","range":"30 A to 90 A","cmc":"0,14 %"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"1 µA 至 100 µA","cmc":"0,08 %"},{"name":"1 kHz 至 5 kHz","range":"1 µA 至 100 µA","cmc":"0,09 %"},{"name":"20 Hz 至 100 Hz","range":"100 µA 至 10 mA","cmc":"0,08 %"},{"name":"100 Hz 至 5 kHz","range":"100 µA 至 10 mA","cmc":"0,05 %"},{"name":"40 Hz 至 70 Hz","range":"10 mA 至 100 mA","cmc":"0,02 %"},{"name":"70 Hz 至 5 kHz","range":"10 mA 至 100 mA","cmc":"0,05 %"},{"name":"40 Hz 至 70 Hz","range":"100 mA 至 1 A","cmc":"0,015 %"},{"name":"70 Hz 至 5 kHz","range":"100 mA 至 1 A","cmc":"0,050 %"},{"name":"40 Hz 至 70 Hz","range":"1 A 至 90 A","cmc":"0,015 %"},{"name":"70 Hz 至 400 Hz","range":"1 A 至 30 A","cmc":"0,07 %"},{"name":"70 Hz 至 400 Hz","range":"30 A 至 90 A","cmc":"0,14 %"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"1 µA až 100 µA","cmc":"0,08 %"},{"name":"1 kHz až 5 kHz","range":"1 µA až 100 µA","cmc":"0,09 %"},{"name":"20 Hz až 100 Hz","range":"100 µA až 10 mA","cmc":"0,08 %"},{"name":"100 Hz až 5 kHz","range":"100 µA až 10 mA","cmc":"0,05 %"},{"name":"40 Hz až 70 Hz","range":"10 mA až 100 mA","cmc":"0,02 %"},{"name":"70 Hz až 5 kHz","range":"10 mA až 100 mA","cmc":"0,05 %"},{"name":"40 Hz až 70 Hz","range":"100 mA až 1 A","cmc":"0,015 %"},{"name":"70 Hz až 5 kHz","range":"100 mA až 1 A","cmc":"0,050 %"},{"name":"40 Hz až 70 Hz","range":"1 A až 90 A","cmc":"0,015 %"},{"name":"70 Hz až 400 Hz","range":"1 A až 30 A","cmc":"0,07 %"},{"name":"70 Hz až 400 Hz","range":"30 A až 90 A","cmc":"0,14 %"}],"technique":"Porównanie z multimetrem wzorcowym z bocznikiem","technique_en":"Comparison with a standard multimeter with a shunt","technique_zh":"与带分流器的标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem s bočníkem","techniques":["Porównanie z multimetrem wzorcowym z bocznikiem"],"techniques_en":["Comparison with a standard multimeter with a shunt"],"techniques_zh":["与带分流器的标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem s bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 1 µA do 100 µA CMC 0,08 %\n1 kHz do 5 kHz od 1 µA do 100 µA CMC 0,09 %\n20 Hz do 100 Hz od 100 µA do 10 mA CMC 0,08 %\n100 Hz do 5 kHz od 100 µA do 10 mA CMC 0,05 %\n40 Hz do 70 Hz od 10 mA do 100 mA CMC 0,02 %\n70 Hz do 5 kHz od 10 mA do 100 mA CMC 0,05 %\n40 Hz do 70 Hz od 100 mA do 1 A CMC 0,015 %\n70 Hz do 5 kHz od 100 mA do 1 A CMC 0,050 %\n40 Hz do 70 Hz od 1 A do 90 A CMC 0,015 %\n70 Hz do 400 Hz od 1 A do 30 A CMC 0,07 %\n70 Hz do 400 Hz od 30 A do 90 A CMC 0,14 %\nPorównanie z multimetrem wzorcowym z bocznikiem","reference":"KP - 04, KP - 05, KP - 06","norm_bases":["KP - 04","KP - 05","KP - 06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym z bocznikiem 40 Hz do 1 kHz od 1 µA do 100 µA CMC 0,08 % 1 kHz do 5 kHz od 1 µA do 100 µA CMC 0,09 % 20 Hz do 100 Hz od 100 µA do 10 mA CMC 0,08 % 100 Hz do 5 kHz od 100 µA do 10 mA CMC 0,05 % 40 Hz do 70 Hz od 10 mA do 100 mA CMC 0,02 % 70 Hz do 5 kHz od 10 mA do 100 mA CMC 0,05 % 40 Hz do 70 Hz od 100 mA do 1 A CMC 0,015 % 70 Hz do 5 kHz od 100 mA do 1 A CMC 0,050 % 40 Hz do 70 Hz od 1 A do 90 A CMC 0,015 % 70 Hz do 400 Hz od 1 A do 30 A CMC 0,07 % 70 Hz do 400 Hz od 30 A do 90 A CMC 0,14 % Střídavý proud / Měřidla Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem s bočníkem 40 Hz až 1 kHz 1 µA až 100 µA CMC 0,08 % 1 kHz až 5 kHz 1 µA až 100 µA CMC 0,09 % 20 Hz až 100 Hz 100 µA až 10 mA CMC 0,08 % 100 Hz až 5 kHz 100 µA až 10 mA CMC 0,05 % 40 Hz až 70 Hz 10 mA až 100 mA CMC 0,02 % 70 Hz až 5 kHz 10 mA až 100 mA CMC 0,05 % 40 Hz až 70 Hz 100 mA až 1 A CMC 0,015 % 70 Hz až 5 kHz 100 mA až 1 A CMC 0,050 % 40 Hz až 70 Hz 1 A až 90 A CMC 0,015 % 70 Hz až 400 Hz 1 A až 30 A CMC 0,07 % 70 Hz až 400 Hz 30 A až 90 A CMC 0,14 % KP - 04, KP - 05, KP - 06 Prad przemienny / mierniki Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym z bocznikiem 40 Hz do 1 kHz od 1 µA do 100 µA CMC 0,08 % 1 kHz do 5 kHz od 1 µA do 100 µA CMC 0,09 % 20 Hz do 100 Hz od 100 µA do 10 mA CMC 0,08 % 100 Hz do 5 kHz od 100 µA do 10 mA CMC 0,05 % 40 Hz do 70 Hz od 10 mA do 100 mA CMC 0,02 % 70 Hz do 5 kHz od 10 mA do 100 mA CMC 0,05 % 40 Hz do 70 Hz od 100 mA do 1 A CMC 0,015 % 70 Hz do 5 kHz od 100 mA do 1 A CMC 0,050 % 40 Hz do 70 Hz od 1 A do 90 A CMC 0,015 % 70 Hz do 400 Hz od 1 A do 30 A CMC 0,07 % 70 Hz do 400 Hz od 30 A do 90 A CMC 0,14 % Stridavy proud / Meridla Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem s bocnikem 40 Hz az 1 kHz 1 µA az 100 µA CMC 0,08 % 1 kHz az 5 kHz 1 µA az 100 µA CMC 0,09 % 20 Hz az 100 Hz 100 µA az 10 mA CMC 0,08 % 100 Hz az 5 kHz 100 µA az 10 mA CMC 0,05 % 40 Hz az 70 Hz 10 mA az 100 mA CMC 0,02 % 70 Hz az 5 kHz 10 mA az 100 mA CMC 0,05 % 40 Hz az 70 Hz 100 mA az 1 A CMC 0,015 % 70 Hz az 5 kHz 100 mA az 1 A CMC 0,050 % 40 Hz az 70 Hz 1 A az 90 A CMC 0,015 % 70 Hz az 400 Hz 1 A az 30 A CMC 0,07 % 70 Hz az 400 Hz 30 A az 90 A CMC 0,14 % KP - 04, KP - 05, KP - 06","search_en":"AC current / Meters Calibration – electrical quantities Comparison with a standard multimeter with a shunt 40 Hz to 1 kHz 1 µA to 100 µA CMC 0,08 % 1 kHz to 5 kHz 1 µA to 100 µA CMC 0,09 % 20 Hz to 100 Hz 100 µA to 10 mA CMC 0,08 % 100 Hz to 5 kHz 100 µA to 10 mA CMC 0,05 % 40 Hz to 70 Hz 10 mA to 100 mA CMC 0,02 % 70 Hz to 5 kHz 10 mA to 100 mA CMC 0,05 % 40 Hz to 70 Hz 100 mA to 1 A CMC 0,015 % 70 Hz to 5 kHz 100 mA to 1 A CMC 0,050 % 40 Hz to 70 Hz 1 A to 90 A CMC 0,015 % 70 Hz to 400 Hz 1 A to 30 A CMC 0,07 % 70 Hz to 400 Hz 30 A to 90 A CMC 0,14 % KP - 04, KP - 05, KP - 06","search_zh":"交流电流 / 测量仪器 校准 – 电学量 与带分流器的标准万用表比较 40 Hz 至 1 kHz 1 µA 至 100 µA CMC 0,08 % 1 kHz 至 5 kHz 1 µA 至 100 µA CMC 0,09 % 20 Hz 至 100 Hz 100 µA 至 10 mA CMC 0,08 % 100 Hz 至 5 kHz 100 µA 至 10 mA CMC 0,05 % 40 Hz 至 70 Hz 10 mA 至 100 mA CMC 0,02 % 70 Hz 至 5 kHz 10 mA 至 100 mA CMC 0,05 % 40 Hz 至 70 Hz 100 mA 至 1 A CMC 0,015 % 70 Hz 至 5 kHz 100 mA 至 1 A CMC 0,050 % 40 Hz 至 70 Hz 1 A 至 90 A CMC 0,015 % 70 Hz 至 400 Hz 1 A 至 30 A CMC 0,07 % 70 Hz 至 400 Hz 30 A 至 90 A CMC 0,14 % KP - 04, KP - 05, KP - 06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2085480a49f850f052eb1877","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / mierniki cęgowe","test_object_en":"AC current / Clamp meters","test_object_zh":"交流电流 / 钳形表","test_object_cs":"Střídavý proud / Klešťová měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 60 Hz","range":"od 0,01 A do 3000 A","cmc":"0,5 %"}],"parameters_en":[{"name":"40 Hz to 60 Hz","range":"0,01 A to 3000 A","cmc":"0,5 %"}],"parameters_zh":[{"name":"40 Hz 至 60 Hz","range":"0,01 A 至 3000 A","cmc":"0,5 %"}],"parameters_cs":[{"name":"40 Hz až 60 Hz","range":"0,01 A až 3000 A","cmc":"0,5 %"}],"technique":"Pomiar pośredni kalibratorem z cewką prądową","technique_en":"Indirect measurement with a calibrator with a current coil","technique_zh":"用带电流线圈的校准器间接测量","technique_cs":"Nepřímé měření kalibrátoru s proudovou cívkou","techniques":["Pomiar pośredni kalibratorem z cewką prądową"],"techniques_en":["Indirect measurement with a calibrator with a current coil"],"techniques_zh":["用带电流线圈的校准器间接测量"],"techniques_cs":["Nepřímé měření kalibrátoru s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n40 Hz do 60 Hz od 0,01 A do 3000 A CMC 0,5 %\nPomiar pośredni kalibratorem z cewką prądową","reference":"KP - 07","norm_bases":["KP - 07"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki cęgowe Wzorcowanie – wielkości elektryczne Pomiar pośredni kalibratorem z cewką prądową 40 Hz do 60 Hz od 0,01 A do 3000 A CMC 0,5 % Střídavý proud / Klešťová měřidla Kalibrace – elektrické veličiny Nepřímé měření kalibrátoru s proudovou cívkou 40 Hz až 60 Hz 0,01 A až 3000 A CMC 0,5 % KP - 07 Prad przemienny / mierniki cegowe Wzorcowanie – wielkosci elektryczne Pomiar posredni kalibratorem z cewka pradowa 40 Hz do 60 Hz od 0,01 A do 3000 A CMC 0,5 % Stridavy proud / Klestova meridla Kalibrace – elektricke veliciny Neprime mereni kalibratoru s proudovou civkou 40 Hz az 60 Hz 0,01 A az 3000 A CMC 0,5 % KP - 07","search_en":"AC current / Clamp meters Calibration – electrical quantities Indirect measurement with a calibrator with a current coil 40 Hz to 60 Hz 0,01 A to 3000 A CMC 0,5 % KP - 07","search_zh":"交流电流 / 钳形表 校准 – 电学量 用带电流线圈的校准器间接测量 40 Hz 至 60 Hz 0,01 A 至 3000 A CMC 0,5 % KP - 07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0053b6246a3e1586ce7ff57c","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / źródła","test_object_en":"AC current / Sources","test_object_zh":"交流电流 / 电流源","test_object_cs":"Střídavý proud / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 1 µA do 100 µA","cmc":"0,08 %"},{"name":"1 kHz do 5 kHz","range":"od 1 µA do 100 µA","cmc":"0,09 %"},{"name":"20 Hz do 100 Hz","range":"od 100 µA do 10 mA","cmc":"0,08 %"},{"name":"100 Hz do 5 kHz","range":"od 100 µA do 10 mA","cmc":"0,05 %"},{"name":"40 Hz do 70 Hz","range":"od 10 mA do 100 mA","cmc":"0,02 %"},{"name":"70 Hz do 5 kHz","range":"od 10 mA do 100 mA","cmc":"0,05 %"},{"name":"40 Hz do 70 Hz","range":"od 100 mA do 1 A","cmc":"0,015 %"},{"name":"70 Hz do 5 kHz","range":"od 100 mA do 1 A","cmc":"0,050 %"},{"name":"40 Hz do 70 Hz","range":"od 1 A do 200 A","cmc":"0,015 %"},{"name":"70 Hz do 400 Hz","range":"od 1 A do 10 A","cmc":"0,03 %"},{"name":"70 Hz do 400 Hz","range":"od 10 A do 200 A","cmc":"0,06 %"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"1 µA to 100 µA","cmc":"0,08 %"},{"name":"1 kHz to 5 kHz","range":"1 µA to 100 µA","cmc":"0,09 %"},{"name":"20 Hz to 100 Hz","range":"100 µA to 10 mA","cmc":"0,08 %"},{"name":"100 Hz to 5 kHz","range":"100 µA to 10 mA","cmc":"0,05 %"},{"name":"40 Hz to 70 Hz","range":"10 mA to 100 mA","cmc":"0,02 %"},{"name":"70 Hz to 5 kHz","range":"10 mA to 100 mA","cmc":"0,05 %"},{"name":"40 Hz to 70 Hz","range":"100 mA to 1 A","cmc":"0,015 %"},{"name":"70 Hz to 5 kHz","range":"100 mA to 1 A","cmc":"0,050 %"},{"name":"40 Hz to 70 Hz","range":"1 A to 200 A","cmc":"0,015 %"},{"name":"70 Hz to 400 Hz","range":"1 A to 10 A","cmc":"0,03 %"},{"name":"70 Hz to 400 Hz","range":"10 A to 200 A","cmc":"0,06 %"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"1 µA 至 100 µA","cmc":"0,08 %"},{"name":"1 kHz 至 5 kHz","range":"1 µA 至 100 µA","cmc":"0,09 %"},{"name":"20 Hz 至 100 Hz","range":"100 µA 至 10 mA","cmc":"0,08 %"},{"name":"100 Hz 至 5 kHz","range":"100 µA 至 10 mA","cmc":"0,05 %"},{"name":"40 Hz 至 70 Hz","range":"10 mA 至 100 mA","cmc":"0,02 %"},{"name":"70 Hz 至 5 kHz","range":"10 mA 至 100 mA","cmc":"0,05 %"},{"name":"40 Hz 至 70 Hz","range":"100 mA 至 1 A","cmc":"0,015 %"},{"name":"70 Hz 至 5 kHz","range":"100 mA 至 1 A","cmc":"0,050 %"},{"name":"40 Hz 至 70 Hz","range":"1 A 至 200 A","cmc":"0,015 %"},{"name":"70 Hz 至 400 Hz","range":"1 A 至 10 A","cmc":"0,03 %"},{"name":"70 Hz 至 400 Hz","range":"10 A 至 200 A","cmc":"0,06 %"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"1 µA až 100 µA","cmc":"0,08 %"},{"name":"1 kHz až 5 kHz","range":"1 µA až 100 µA","cmc":"0,09 %"},{"name":"20 Hz až 100 Hz","range":"100 µA až 10 mA","cmc":"0,08 %"},{"name":"100 Hz až 5 kHz","range":"100 µA až 10 mA","cmc":"0,05 %"},{"name":"40 Hz až 70 Hz","range":"10 mA až 100 mA","cmc":"0,02 %"},{"name":"70 Hz až 5 kHz","range":"10 mA až 100 mA","cmc":"0,05 %"},{"name":"40 Hz až 70 Hz","range":"100 mA až 1 A","cmc":"0,015 %"},{"name":"70 Hz až 5 kHz","range":"100 mA až 1 A","cmc":"0,050 %"},{"name":"40 Hz až 70 Hz","range":"1 A až 200 A","cmc":"0,015 %"},{"name":"70 Hz až 400 Hz","range":"1 A až 10 A","cmc":"0,03 %"},{"name":"70 Hz až 400 Hz","range":"10 A až 200 A","cmc":"0,06 %"}],"technique":"Pomiar bezpośredni multimetrem, multimetrem z bocznikiem","technique_en":"Direct measurement with a multimeter, with a multimeter with a shunt","technique_zh":"用万用表、带分流器的万用表直接测量","technique_cs":"Přímé měření multimetrem, multimetrem s bočníkem","techniques":["Pomiar bezpośredni multimetrem, multimetrem z bocznikiem"],"techniques_en":["Direct measurement with a multimeter, with a multimeter with a shunt"],"techniques_zh":["用万用表、带分流器的万用表直接测量"],"techniques_cs":["Přímé měření multimetrem, multimetrem s bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 1 µA do 100 µA CMC 0,08 %\n1 kHz do 5 kHz od 1 µA do 100 µA CMC 0,09 %\n20 Hz do 100 Hz od 100 µA do 10 mA CMC 0,08 %\n100 Hz do 5 kHz od 100 µA do 10 mA CMC 0,05 %\n40 Hz do 70 Hz od 10 mA do 100 mA CMC 0,02 %\n70 Hz do 5 kHz od 10 mA do 100 mA CMC 0,05 %\n40 Hz do 70 Hz od 100 mA do 1 A CMC 0,015 %\n70 Hz do 5 kHz od 100 mA do 1 A CMC 0,050 %\n40 Hz do 70 Hz od 1 A do 200 A CMC 0,015 %\n70 Hz do 400 Hz od 1 A do 10 A CMC 0,03 %\n70 Hz do 400 Hz od 10 A do 200 A CMC 0,06 %\nPomiar bezpośredni multimetrem, multimetrem z bocznikiem","reference":"KP - 08","norm_bases":["KP - 08"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem, multimetrem z bocznikiem 40 Hz do 1 kHz od 1 µA do 100 µA CMC 0,08 % 1 kHz do 5 kHz od 1 µA do 100 µA CMC 0,09 % 20 Hz do 100 Hz od 100 µA do 10 mA CMC 0,08 % 100 Hz do 5 kHz od 100 µA do 10 mA CMC 0,05 % 40 Hz do 70 Hz od 10 mA do 100 mA CMC 0,02 % 70 Hz do 5 kHz od 10 mA do 100 mA CMC 0,05 % 40 Hz do 70 Hz od 100 mA do 1 A CMC 0,015 % 70 Hz do 5 kHz od 100 mA do 1 A CMC 0,050 % 40 Hz do 70 Hz od 1 A do 200 A CMC 0,015 % 70 Hz do 400 Hz od 1 A do 10 A CMC 0,03 % 70 Hz do 400 Hz od 10 A do 200 A CMC 0,06 % Střídavý proud / Zdroje Kalibrace – elektrické veličiny Přímé měření multimetrem, multimetrem s bočníkem 40 Hz až 1 kHz 1 µA až 100 µA CMC 0,08 % 1 kHz až 5 kHz 1 µA až 100 µA CMC 0,09 % 20 Hz až 100 Hz 100 µA až 10 mA CMC 0,08 % 100 Hz až 5 kHz 100 µA až 10 mA CMC 0,05 % 40 Hz až 70 Hz 10 mA až 100 mA CMC 0,02 % 70 Hz až 5 kHz 10 mA až 100 mA CMC 0,05 % 40 Hz až 70 Hz 100 mA až 1 A CMC 0,015 % 70 Hz až 5 kHz 100 mA až 1 A CMC 0,050 % 40 Hz až 70 Hz 1 A až 200 A CMC 0,015 % 70 Hz až 400 Hz 1 A až 10 A CMC 0,03 % 70 Hz až 400 Hz 10 A až 200 A CMC 0,06 % KP - 08 Prad przemienny / zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem, multimetrem z bocznikiem 40 Hz do 1 kHz od 1 µA do 100 µA CMC 0,08 % 1 kHz do 5 kHz od 1 µA do 100 µA CMC 0,09 % 20 Hz do 100 Hz od 100 µA do 10 mA CMC 0,08 % 100 Hz do 5 kHz od 100 µA do 10 mA CMC 0,05 % 40 Hz do 70 Hz od 10 mA do 100 mA CMC 0,02 % 70 Hz do 5 kHz od 10 mA do 100 mA CMC 0,05 % 40 Hz do 70 Hz od 100 mA do 1 A CMC 0,015 % 70 Hz do 5 kHz od 100 mA do 1 A CMC 0,050 % 40 Hz do 70 Hz od 1 A do 200 A CMC 0,015 % 70 Hz do 400 Hz od 1 A do 10 A CMC 0,03 % 70 Hz do 400 Hz od 10 A do 200 A CMC 0,06 % Stridavy proud / Zdroje Kalibrace – elektricke veliciny Prime mereni multimetrem, multimetrem s bocnikem 40 Hz az 1 kHz 1 µA az 100 µA CMC 0,08 % 1 kHz az 5 kHz 1 µA az 100 µA CMC 0,09 % 20 Hz az 100 Hz 100 µA az 10 mA CMC 0,08 % 100 Hz az 5 kHz 100 µA az 10 mA CMC 0,05 % 40 Hz az 70 Hz 10 mA az 100 mA CMC 0,02 % 70 Hz az 5 kHz 10 mA az 100 mA CMC 0,05 % 40 Hz az 70 Hz 100 mA az 1 A CMC 0,015 % 70 Hz az 5 kHz 100 mA az 1 A CMC 0,050 % 40 Hz az 70 Hz 1 A az 200 A CMC 0,015 % 70 Hz az 400 Hz 1 A az 10 A CMC 0,03 % 70 Hz az 400 Hz 10 A az 200 A CMC 0,06 % KP - 08","search_en":"AC current / Sources Calibration – electrical quantities Direct measurement with a multimeter, with a multimeter with a shunt 40 Hz to 1 kHz 1 µA to 100 µA CMC 0,08 % 1 kHz to 5 kHz 1 µA to 100 µA CMC 0,09 % 20 Hz to 100 Hz 100 µA to 10 mA CMC 0,08 % 100 Hz to 5 kHz 100 µA to 10 mA CMC 0,05 % 40 Hz to 70 Hz 10 mA to 100 mA CMC 0,02 % 70 Hz to 5 kHz 10 mA to 100 mA CMC 0,05 % 40 Hz to 70 Hz 100 mA to 1 A CMC 0,015 % 70 Hz to 5 kHz 100 mA to 1 A CMC 0,050 % 40 Hz to 70 Hz 1 A to 200 A CMC 0,015 % 70 Hz to 400 Hz 1 A to 10 A CMC 0,03 % 70 Hz to 400 Hz 10 A to 200 A CMC 0,06 % KP - 08","search_zh":"交流电流 / 电流源 校准 – 电学量 用万用表、带分流器的万用表直接测量 40 Hz 至 1 kHz 1 µA 至 100 µA CMC 0,08 % 1 kHz 至 5 kHz 1 µA 至 100 µA CMC 0,09 % 20 Hz 至 100 Hz 100 µA 至 10 mA CMC 0,08 % 100 Hz 至 5 kHz 100 µA 至 10 mA CMC 0,05 % 40 Hz 至 70 Hz 10 mA 至 100 mA CMC 0,02 % 70 Hz 至 5 kHz 10 mA 至 100 mA CMC 0,05 % 40 Hz 至 70 Hz 100 mA 至 1 A CMC 0,015 % 70 Hz 至 5 kHz 100 mA 至 1 A CMC 0,050 % 40 Hz 至 70 Hz 1 A 至 200 A CMC 0,015 % 70 Hz 至 400 Hz 1 A 至 10 A CMC 0,03 % 70 Hz 至 400 Hz 10 A 至 200 A CMC 0,06 % KP - 08","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"36ea3534df23d21e09fe7091","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / mierniki","test_object_en":"DC resistance / Meters","test_object_zh":"直流电阻 / 测量仪器","test_object_cs":"Stejnosměrný odpor / Měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"60 µΩ","cmc":"0,01 µΩ"},{"name":"","range":"100 µΩ","cmc":"0,01 µΩ"},{"name":"","range":"300 µΩ","cmc":"0,02 µΩ"},{"name":"","range":"600 µΩ","cmc":"0,12 µΩ"},{"name":"","range":"1 mΩ","cmc":"0,02 µΩ"},{"name":"","range":"2 mΩ","cmc":"0,3 µΩ"},{"name":"","range":"5 mΩ","cmc":"0,8 µΩ"},{"name":"","range":"10 mΩ","cmc":"0,08 µΩ"},{"name":"","range":"od 1 mΩ do 100 mΩ","cmc":"0,004 % + 0,5 µΩ"},{"name":"","range":"od 100 mΩ do 200 mΩ","cmc":"0,003 % + 0,5 µΩ"},{"name":"","range":"od 200 mΩ do 1 Ω","cmc":"0,0006 % + 0,5 µΩ"},{"name":"","range":"od 1 Ω do 100 Ω","cmc":"0,0015 % + 5 µΩ"},{"name":"","range":"od 100 Ω do 100 kΩ","cmc":"0,0012 %"},{"name":"","range":"od 100 kΩ do 1 MΩ","cmc":"0,0020 %"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,0070 %"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,060 %"},{"name":"","range":"od 100 MΩ do 1 GΩ","cmc":"0,15 %"},{"name":"","range":"od 1 GΩ do 10 GΩ","cmc":"0,3 %"},{"name":"","range":"od 10 GΩ do 100 GΩ","cmc":"0,5 %"},{"name":"","range":"od 100 GΩ do 1 TΩ","cmc":"1 %"},{"name":"","range":"od 1 TΩ do 10 TΩ","cmc":"2 %"}],"parameters_en":[{"name":"","range":"60 µΩ","cmc":"0,01 µΩ"},{"name":"","range":"100 µΩ","cmc":"0,01 µΩ"},{"name":"","range":"300 µΩ","cmc":"0,02 µΩ"},{"name":"","range":"600 µΩ","cmc":"0,12 µΩ"},{"name":"","range":"1 mΩ","cmc":"0,02 µΩ"},{"name":"","range":"2 mΩ","cmc":"0,3 µΩ"},{"name":"","range":"5 mΩ","cmc":"0,8 µΩ"},{"name":"","range":"10 mΩ","cmc":"0,08 µΩ"},{"name":"","range":"1 mΩ to 100 mΩ","cmc":"0,004 % + 0,5 µΩ"},{"name":"","range":"100 mΩ to 200 mΩ","cmc":"0,003 % + 0,5 µΩ"},{"name":"","range":"200 mΩ to 1 Ω","cmc":"0,0006 % + 0,5 µΩ"},{"name":"","range":"1 Ω to 100 Ω","cmc":"0,0015 % + 5 µΩ"},{"name":"","range":"100 Ω to 100 kΩ","cmc":"0,0012 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0020 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,0070 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,060 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,15 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,3 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,5 %"},{"name":"","range":"100 GΩ to 1 TΩ","cmc":"1 %"},{"name":"","range":"1 TΩ to 10 TΩ","cmc":"2 %"}],"parameters_zh":[{"name":"","range":"60 µΩ","cmc":"0,01 µΩ"},{"name":"","range":"100 µΩ","cmc":"0,01 µΩ"},{"name":"","range":"300 µΩ","cmc":"0,02 µΩ"},{"name":"","range":"600 µΩ","cmc":"0,12 µΩ"},{"name":"","range":"1 mΩ","cmc":"0,02 µΩ"},{"name":"","range":"2 mΩ","cmc":"0,3 µΩ"},{"name":"","range":"5 mΩ","cmc":"0,8 µΩ"},{"name":"","range":"10 mΩ","cmc":"0,08 µΩ"},{"name":"","range":"1 mΩ 至 100 mΩ","cmc":"0,004 % + 0,5 µΩ"},{"name":"","range":"100 mΩ 至 200 mΩ","cmc":"0,003 % + 0,5 µΩ"},{"name":"","range":"200 mΩ 至 1 Ω","cmc":"0,0006 % + 0,5 µΩ"},{"name":"","range":"1 Ω 至 100 Ω","cmc":"0,0015 % + 5 µΩ"},{"name":"","range":"100 Ω 至 100 kΩ","cmc":"0,0012 %"},{"name":"","range":"100 kΩ 至 1 MΩ","cmc":"0,0020 %"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,0070 %"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,060 %"},{"name":"","range":"100 MΩ 至 1 GΩ","cmc":"0,15 %"},{"name":"","range":"1 GΩ 至 10 GΩ","cmc":"0,3 %"},{"name":"","range":"10 GΩ 至 100 GΩ","cmc":"0,5 %"},{"name":"","range":"100 GΩ 至 1 TΩ","cmc":"1 %"},{"name":"","range":"1 TΩ 至 10 TΩ","cmc":"2 %"}],"parameters_cs":[{"name":"","range":"60 µΩ","cmc":"0,01 µΩ"},{"name":"","range":"100 µΩ","cmc":"0,01 µΩ"},{"name":"","range":"300 µΩ","cmc":"0,02 µΩ"},{"name":"","range":"600 µΩ","cmc":"0,12 µΩ"},{"name":"","range":"1 mΩ","cmc":"0,02 µΩ"},{"name":"","range":"2 mΩ","cmc":"0,3 µΩ"},{"name":"","range":"5 mΩ","cmc":"0,8 µΩ"},{"name":"","range":"10 mΩ","cmc":"0,08 µΩ"},{"name":"","range":"1 mΩ až 100 mΩ","cmc":"0,004 % + 0,5 µΩ"},{"name":"","range":"100 mΩ až 200 mΩ","cmc":"0,003 % + 0,5 µΩ"},{"name":"","range":"200 mΩ až 1 Ω","cmc":"0,0006 % + 0,5 µΩ"},{"name":"","range":"1 Ω až 100 Ω","cmc":"0,0015 % + 5 µΩ"},{"name":"","range":"100 Ω až 100 kΩ","cmc":"0,0012 %"},{"name":"","range":"100 kΩ až 1 MΩ","cmc":"0,0020 %"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,0070 %"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,060 %"},{"name":"","range":"100 MΩ až 1 GΩ","cmc":"0,15 %"},{"name":"","range":"1 GΩ až 10 GΩ","cmc":"0,3 %"},{"name":"","range":"10 GΩ až 100 GΩ","cmc":"0,5 %"},{"name":"","range":"100 GΩ až 1 TΩ","cmc":"1 %"},{"name":"","range":"1 TΩ až 10 TΩ","cmc":"2 %"}],"technique":"Pomiar bezpośredni wzorców rezystancji lub dekady rezystancyjnej","technique_en":"Direct measurement of resistance standards or a resistance decade","technique_zh":"直接测量电阻标准器或电阻箱","technique_cs":"Přímé měření etalonů odporu nebo odporové dekády","techniques":["Pomiar bezpośredni wzorców rezystancji lub dekady rezystancyjnej"],"techniques_en":["Direct measurement of resistance standards or a resistance decade"],"techniques_zh":["直接测量电阻标准器或电阻箱"],"techniques_cs":["Přímé měření etalonů odporu nebo odporové dekády"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n60 µΩ CMC 0,01 µΩ\n100 µΩ CMC 0,01 µΩ\n300 µΩ CMC 0,02 µΩ\n600 µΩ CMC 0,12 µΩ\n1 mΩ CMC 0,02 µΩ\n2 mΩ CMC 0,3 µΩ\n5 mΩ CMC 0,8 µΩ\n10 mΩ CMC 0,08 µΩ\nod 1 mΩ do 100 mΩ CMC 0,004 % + 0,5 µΩ\nod 100 mΩ do 200 mΩ CMC 0,003 % + 0,5 µΩ\nod 200 mΩ do 1 Ω CMC 0,0006 % + 0,5 µΩ\nod 1 Ω do 100 Ω CMC 0,0015 % + 5 µΩ\nod 100 Ω do 100 kΩ CMC 0,0012 %\nod 100 kΩ do 1 MΩ CMC 0,0020 %\nod 1 MΩ do 10 MΩ CMC 0,0070 %\nod 10 MΩ do 100 MΩ CMC 0,060 %\nod 100 MΩ do 1 GΩ CMC 0,15 %\nod 1 GΩ do 10 GΩ CMC 0,3 %\nod 10 GΩ do 100 GΩ CMC 0,5 %\nod 100 GΩ do 1 TΩ CMC 1 %\nod 1 TΩ do 10 TΩ CMC 2 %\nPomiar bezpośredni wzorców rezystancji lub dekady rezystancyjnej","reference":"KP - 05, KP - 06, KP - 09, KP - 16","norm_bases":["KP - 05","KP - 06","KP - 09","KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / mierniki Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorców rezystancji lub dekady rezystancyjnej 60 µΩ CMC 0,01 µΩ 100 µΩ CMC 0,01 µΩ 300 µΩ CMC 0,02 µΩ 600 µΩ CMC 0,12 µΩ 1 mΩ CMC 0,02 µΩ 2 mΩ CMC 0,3 µΩ 5 mΩ CMC 0,8 µΩ 10 mΩ CMC 0,08 µΩ od 1 mΩ do 100 mΩ CMC 0,004 % + 0,5 µΩ od 100 mΩ do 200 mΩ CMC 0,003 % + 0,5 µΩ od 200 mΩ do 1 Ω CMC 0,0006 % + 0,5 µΩ od 1 Ω do 100 Ω CMC 0,0015 % + 5 µΩ od 100 Ω do 100 kΩ CMC 0,0012 % od 100 kΩ do 1 MΩ CMC 0,0020 % od 1 MΩ do 10 MΩ CMC 0,0070 % od 10 MΩ do 100 MΩ CMC 0,060 % od 100 MΩ do 1 GΩ CMC 0,15 % od 1 GΩ do 10 GΩ CMC 0,3 % od 10 GΩ do 100 GΩ CMC 0,5 % od 100 GΩ do 1 TΩ CMC 1 % od 1 TΩ do 10 TΩ CMC 2 % Stejnosměrný odpor / Měřidla Kalibrace – elektrické veličiny Přímé měření etalonů odporu nebo odporové dekády 60 µΩ CMC 0,01 µΩ 100 µΩ CMC 0,01 µΩ 300 µΩ CMC 0,02 µΩ 600 µΩ CMC 0,12 µΩ 1 mΩ CMC 0,02 µΩ 2 mΩ CMC 0,3 µΩ 5 mΩ CMC 0,8 µΩ 10 mΩ CMC 0,08 µΩ 1 mΩ až 100 mΩ CMC 0,004 % + 0,5 µΩ 100 mΩ až 200 mΩ CMC 0,003 % + 0,5 µΩ 200 mΩ až 1 Ω CMC 0,0006 % + 0,5 µΩ 1 Ω až 100 Ω CMC 0,0015 % + 5 µΩ 100 Ω až 100 kΩ CMC 0,0012 % 100 kΩ až 1 MΩ CMC 0,0020 % 1 MΩ až 10 MΩ CMC 0,0070 % 10 MΩ až 100 MΩ CMC 0,060 % 100 MΩ až 1 GΩ CMC 0,15 % 1 GΩ až 10 GΩ CMC 0,3 % 10 GΩ až 100 GΩ CMC 0,5 % 100 GΩ až 1 TΩ CMC 1 % 1 TΩ až 10 TΩ CMC 2 % KP - 05, KP - 06, KP - 09, KP - 16 Rezystancja przy pradzie stalym / mierniki Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcow rezystancji lub dekady rezystancyjnej 60 µΩ CMC 0,01 µΩ 100 µΩ CMC 0,01 µΩ 300 µΩ CMC 0,02 µΩ 600 µΩ CMC 0,12 µΩ 1 mΩ CMC 0,02 µΩ 2 mΩ CMC 0,3 µΩ 5 mΩ CMC 0,8 µΩ 10 mΩ CMC 0,08 µΩ od 1 mΩ do 100 mΩ CMC 0,004 % + 0,5 µΩ od 100 mΩ do 200 mΩ CMC 0,003 % + 0,5 µΩ od 200 mΩ do 1 Ω CMC 0,0006 % + 0,5 µΩ od 1 Ω do 100 Ω CMC 0,0015 % + 5 µΩ od 100 Ω do 100 kΩ CMC 0,0012 % od 100 kΩ do 1 MΩ CMC 0,0020 % od 1 MΩ do 10 MΩ CMC 0,0070 % od 10 MΩ do 100 MΩ CMC 0,060 % od 100 MΩ do 1 GΩ CMC 0,15 % od 1 GΩ do 10 GΩ CMC 0,3 % od 10 GΩ do 100 GΩ CMC 0,5 % od 100 GΩ do 1 TΩ CMC 1 % od 1 TΩ do 10 TΩ CMC 2 % Stejnosmerny odpor / Meridla Kalibrace – elektricke veliciny Prime mereni etalonu odporu nebo odporove dekady 60 µΩ CMC 0,01 µΩ 100 µΩ CMC 0,01 µΩ 300 µΩ CMC 0,02 µΩ 600 µΩ CMC 0,12 µΩ 1 mΩ CMC 0,02 µΩ 2 mΩ CMC 0,3 µΩ 5 mΩ CMC 0,8 µΩ 10 mΩ CMC 0,08 µΩ 1 mΩ az 100 mΩ CMC 0,004 % + 0,5 µΩ 100 mΩ az 200 mΩ CMC 0,003 % + 0,5 µΩ 200 mΩ az 1 Ω CMC 0,0006 % + 0,5 µΩ 1 Ω az 100 Ω CMC 0,0015 % + 5 µΩ 100 Ω az 100 kΩ CMC 0,0012 % 100 kΩ az 1 MΩ CMC 0,0020 % 1 MΩ az 10 MΩ CMC 0,0070 % 10 MΩ az 100 MΩ CMC 0,060 % 100 MΩ az 1 GΩ CMC 0,15 % 1 GΩ az 10 GΩ CMC 0,3 % 10 GΩ az 100 GΩ CMC 0,5 % 100 GΩ az 1 TΩ CMC 1 % 1 TΩ az 10 TΩ CMC 2 % KP - 05, KP - 06, KP - 09, KP - 16","search_en":"DC resistance / Meters Calibration – electrical quantities Direct measurement of resistance standards or a resistance decade 60 µΩ CMC 0,01 µΩ 100 µΩ CMC 0,01 µΩ 300 µΩ CMC 0,02 µΩ 600 µΩ CMC 0,12 µΩ 1 mΩ CMC 0,02 µΩ 2 mΩ CMC 0,3 µΩ 5 mΩ CMC 0,8 µΩ 10 mΩ CMC 0,08 µΩ 1 mΩ to 100 mΩ CMC 0,004 % + 0,5 µΩ 100 mΩ to 200 mΩ CMC 0,003 % + 0,5 µΩ 200 mΩ to 1 Ω CMC 0,0006 % + 0,5 µΩ 1 Ω to 100 Ω CMC 0,0015 % + 5 µΩ 100 Ω to 100 kΩ CMC 0,0012 % 100 kΩ to 1 MΩ CMC 0,0020 % 1 MΩ to 10 MΩ CMC 0,0070 % 10 MΩ to 100 MΩ CMC 0,060 % 100 MΩ to 1 GΩ CMC 0,15 % 1 GΩ to 10 GΩ CMC 0,3 % 10 GΩ to 100 GΩ CMC 0,5 % 100 GΩ to 1 TΩ CMC 1 % 1 TΩ to 10 TΩ CMC 2 % KP - 05, KP - 06, KP - 09, KP - 16","search_zh":"直流电阻 / 测量仪器 校准 – 电学量 直接测量电阻标准器或电阻箱 60 µΩ CMC 0,01 µΩ 100 µΩ CMC 0,01 µΩ 300 µΩ CMC 0,02 µΩ 600 µΩ CMC 0,12 µΩ 1 mΩ CMC 0,02 µΩ 2 mΩ CMC 0,3 µΩ 5 mΩ CMC 0,8 µΩ 10 mΩ CMC 0,08 µΩ 1 mΩ 至 100 mΩ CMC 0,004 % + 0,5 µΩ 100 mΩ 至 200 mΩ CMC 0,003 % + 0,5 µΩ 200 mΩ 至 1 Ω CMC 0,0006 % + 0,5 µΩ 1 Ω 至 100 Ω CMC 0,0015 % + 5 µΩ 100 Ω 至 100 kΩ CMC 0,0012 % 100 kΩ 至 1 MΩ CMC 0,0020 % 1 MΩ 至 10 MΩ CMC 0,0070 % 10 MΩ 至 100 MΩ CMC 0,060 % 100 MΩ 至 1 GΩ CMC 0,15 % 1 GΩ 至 10 GΩ CMC 0,3 % 10 GΩ 至 100 GΩ CMC 0,5 % 100 GΩ 至 1 TΩ CMC 1 % 1 TΩ 至 10 TΩ CMC 2 % KP - 05, KP - 06, KP - 09, KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca885d6d2618d2b4ec78f595","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / wzorce","test_object_en":"DC resistance / Standards","test_object_zh":"直流电阻 / 标准器","test_object_cs":"Stejnosměrný odpor / Etalony","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 600 µΩ do 1 mΩ","cmc":"0,12 µΩ"},{"name":"","range":"od 100 MΩ do 20 GΩ","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"600 µΩ to 1 mΩ","cmc":"0,12 µΩ"},{"name":"","range":"100 MΩ to 20 GΩ","cmc":"0,2 %"}],"parameters_zh":[{"name":"","range":"600 µΩ 至 1 mΩ","cmc":"0,12 µΩ"},{"name":"","range":"100 MΩ 至 20 GΩ","cmc":"0,2 %"}],"parameters_cs":[{"name":"","range":"600 µΩ až 1 mΩ","cmc":"0,12 µΩ"},{"name":"","range":"100 MΩ až 20 GΩ","cmc":"0,2 %"}],"technique":"Metoda techniczna (woltamperomierzowa)","technique_en":"Voltammeter–ammeter method","technique_zh":"伏安法","technique_cs":"Voltampérová metoda","techniques":["Metoda techniczna (woltamperomierzowa)"],"techniques_en":["Voltammeter–ammeter method"],"techniques_zh":["伏安法"],"techniques_cs":["Voltampérová metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 600 µΩ do 1 mΩ CMC 0,12 µΩ\nod 100 MΩ do 20 GΩ CMC 0,2 %\nMetoda techniczna (woltamperomierzowa)","reference":"KP - 09, KP - 16","norm_bases":["KP - 09","KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / wzorce Wzorcowanie – wielkości elektryczne Metoda techniczna (woltamperomierzowa) od 600 µΩ do 1 mΩ CMC 0,12 µΩ od 100 MΩ do 20 GΩ CMC 0,2 % Stejnosměrný odpor / Etalony Kalibrace – elektrické veličiny Voltampérová metoda 600 µΩ až 1 mΩ CMC 0,12 µΩ 100 MΩ až 20 GΩ CMC 0,2 % KP - 09, KP - 16 Rezystancja przy pradzie stalym / wzorce Wzorcowanie – wielkosci elektryczne Metoda techniczna (woltamperomierzowa) od 600 µΩ do 1 mΩ CMC 0,12 µΩ od 100 MΩ do 20 GΩ CMC 0,2 % Stejnosmerny odpor / Etalony Kalibrace – elektricke veliciny Voltamperova metoda 600 µΩ az 1 mΩ CMC 0,12 µΩ 100 MΩ az 20 GΩ CMC 0,2 % KP - 09, KP - 16","search_en":"DC resistance / Standards Calibration – electrical quantities Voltammeter–ammeter method 600 µΩ to 1 mΩ CMC 0,12 µΩ 100 MΩ to 20 GΩ CMC 0,2 % KP - 09, KP - 16","search_zh":"直流电阻 / 标准器 校准 – 电学量 伏安法 600 µΩ 至 1 mΩ CMC 0,12 µΩ 100 MΩ 至 20 GΩ CMC 0,2 % KP - 09, KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4097293f130e319db7ca5e28","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / wzorce","test_object_en":"DC resistance / Standards","test_object_zh":"直流电阻 / 标准器","test_object_cs":"Stejnosměrný odpor / Etalony","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 mΩ do 10 mΩ","cmc":"0,008 % + 0,5 µΩ"},{"name":"","range":"od 10 mΩ do 100 mΩ","cmc":"0,004 % + 0,5 µΩ"},{"name":"","range":"od 100 mΩ do 10 Ω","cmc":"0,003 % + 0,5 µΩ"}],"parameters_en":[{"name":"","range":"1 mΩ to 10 mΩ","cmc":"0,008 % + 0,5 µΩ"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"0,004 % + 0,5 µΩ"},{"name":"","range":"100 mΩ to 10 Ω","cmc":"0,003 % + 0,5 µΩ"}],"parameters_zh":[{"name":"","range":"1 mΩ 至 10 mΩ","cmc":"0,008 % + 0,5 µΩ"},{"name":"","range":"10 mΩ 至 100 mΩ","cmc":"0,004 % + 0,5 µΩ"},{"name":"","range":"100 mΩ 至 10 Ω","cmc":"0,003 % + 0,5 µΩ"}],"parameters_cs":[{"name":"","range":"1 mΩ až 10 mΩ","cmc":"0,008 % + 0,5 µΩ"},{"name":"","range":"10 mΩ až 100 mΩ","cmc":"0,004 % + 0,5 µΩ"},{"name":"","range":"100 mΩ až 10 Ω","cmc":"0,003 % + 0,5 µΩ"}],"technique":"Porównywanie metodą ilorazową","technique_en":"Comparison by the ratio method","technique_zh":"比率法比较","technique_cs":"Porovnávání poměrovou metodou","techniques":["Porównywanie metodą ilorazową"],"techniques_en":["Comparison by the ratio method"],"techniques_zh":["比率法比较"],"techniques_cs":["Porovnávání poměrovou metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 mΩ do 10 mΩ CMC 0,008 % + 0,5 µΩ\nod 10 mΩ do 100 mΩ CMC 0,004 % + 0,5 µΩ\nod 100 mΩ do 10 Ω CMC 0,003 % + 0,5 µΩ\nPorównywanie metodą ilorazową","reference":"KP - 09, KP - 16","norm_bases":["KP - 09","KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / wzorce Wzorcowanie – wielkości elektryczne Porównywanie metodą ilorazową od 1 mΩ do 10 mΩ CMC 0,008 % + 0,5 µΩ od 10 mΩ do 100 mΩ CMC 0,004 % + 0,5 µΩ od 100 mΩ do 10 Ω CMC 0,003 % + 0,5 µΩ Stejnosměrný odpor / Etalony Kalibrace – elektrické veličiny Porovnávání poměrovou metodou 1 mΩ až 10 mΩ CMC 0,008 % + 0,5 µΩ 10 mΩ až 100 mΩ CMC 0,004 % + 0,5 µΩ 100 mΩ až 10 Ω CMC 0,003 % + 0,5 µΩ KP - 09, KP - 16 Rezystancja przy pradzie stalym / wzorce Wzorcowanie – wielkosci elektryczne Porownywanie metoda ilorazowa od 1 mΩ do 10 mΩ CMC 0,008 % + 0,5 µΩ od 10 mΩ do 100 mΩ CMC 0,004 % + 0,5 µΩ od 100 mΩ do 10 Ω CMC 0,003 % + 0,5 µΩ Stejnosmerny odpor / Etalony Kalibrace – elektricke veliciny Porovnavani pomerovou metodou 1 mΩ az 10 mΩ CMC 0,008 % + 0,5 µΩ 10 mΩ az 100 mΩ CMC 0,004 % + 0,5 µΩ 100 mΩ az 10 Ω CMC 0,003 % + 0,5 µΩ KP - 09, KP - 16","search_en":"DC resistance / Standards Calibration – electrical quantities Comparison by the ratio method 1 mΩ to 10 mΩ CMC 0,008 % + 0,5 µΩ 10 mΩ to 100 mΩ CMC 0,004 % + 0,5 µΩ 100 mΩ to 10 Ω CMC 0,003 % + 0,5 µΩ KP - 09, KP - 16","search_zh":"直流电阻 / 标准器 校准 – 电学量 比率法比较 1 mΩ 至 10 mΩ CMC 0,008 % + 0,5 µΩ 10 mΩ 至 100 mΩ CMC 0,004 % + 0,5 µΩ 100 mΩ 至 10 Ω CMC 0,003 % + 0,5 µΩ KP - 09, KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2858604504919ad258d98352","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / wzorce","test_object_en":"DC resistance / Standards","test_object_zh":"直流电阻 / 标准器","test_object_cs":"Stejnosměrný odpor / Etalony","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 Ω do 100 Ω","cmc":"0,0015 % + 5 µΩ"},{"name":"","range":"od 100 Ω do 100 kΩ","cmc":"0,0012 %"},{"name":"","range":"od 100 kΩ do 1 MΩ","cmc":"0,0020 %"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,0070 %"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,060 %"}],"parameters_en":[{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0015 % + 5 µΩ"},{"name":"","range":"100 Ω to 100 kΩ","cmc":"0,0012 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0020 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,0070 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,060 %"}],"parameters_zh":[{"name":"","range":"10 Ω 至 100 Ω","cmc":"0,0015 % + 5 µΩ"},{"name":"","range":"100 Ω 至 100 kΩ","cmc":"0,0012 %"},{"name":"","range":"100 kΩ 至 1 MΩ","cmc":"0,0020 %"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,0070 %"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,060 %"}],"parameters_cs":[{"name":"","range":"10 Ω až 100 Ω","cmc":"0,0015 % + 5 µΩ"},{"name":"","range":"100 Ω až 100 kΩ","cmc":"0,0012 %"},{"name":"","range":"100 kΩ až 1 MΩ","cmc":"0,0020 %"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,0070 %"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,060 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement with a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement with a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 10 Ω do 100 Ω CMC 0,0015 % + 5 µΩ\nod 100 Ω do 100 kΩ CMC 0,0012 %\nod 100 kΩ do 1 MΩ CMC 0,0020 %\nod 1 MΩ do 10 MΩ CMC 0,0070 %\nod 10 MΩ do 100 MΩ CMC 0,060 %\nPomiar bezpośredni multimetrem","reference":"KP - 09, KP - 16","norm_bases":["KP - 09","KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / wzorce Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 10 Ω do 100 Ω CMC 0,0015 % + 5 µΩ od 100 Ω do 100 kΩ CMC 0,0012 % od 100 kΩ do 1 MΩ CMC 0,0020 % od 1 MΩ do 10 MΩ CMC 0,0070 % od 10 MΩ do 100 MΩ CMC 0,060 % Stejnosměrný odpor / Etalony Kalibrace – elektrické veličiny Přímé měření multimetrem 10 Ω až 100 Ω CMC 0,0015 % + 5 µΩ 100 Ω až 100 kΩ CMC 0,0012 % 100 kΩ až 1 MΩ CMC 0,0020 % 1 MΩ až 10 MΩ CMC 0,0070 % 10 MΩ až 100 MΩ CMC 0,060 % KP - 09, KP - 16 Rezystancja przy pradzie stalym / wzorce Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 10 Ω do 100 Ω CMC 0,0015 % + 5 µΩ od 100 Ω do 100 kΩ CMC 0,0012 % od 100 kΩ do 1 MΩ CMC 0,0020 % od 1 MΩ do 10 MΩ CMC 0,0070 % od 10 MΩ do 100 MΩ CMC 0,060 % Stejnosmerny odpor / Etalony Kalibrace – elektricke veliciny Prime mereni multimetrem 10 Ω az 100 Ω CMC 0,0015 % + 5 µΩ 100 Ω az 100 kΩ CMC 0,0012 % 100 kΩ az 1 MΩ CMC 0,0020 % 1 MΩ az 10 MΩ CMC 0,0070 % 10 MΩ az 100 MΩ CMC 0,060 % KP - 09, KP - 16","search_en":"DC resistance / Standards Calibration – electrical quantities Direct measurement with a multimeter 10 Ω to 100 Ω CMC 0,0015 % + 5 µΩ 100 Ω to 100 kΩ CMC 0,0012 % 100 kΩ to 1 MΩ CMC 0,0020 % 1 MΩ to 10 MΩ CMC 0,0070 % 10 MΩ to 100 MΩ CMC 0,060 % KP - 09, KP - 16","search_zh":"直流电阻 / 标准器 校准 – 电学量 用万用表直接测量 10 Ω 至 100 Ω CMC 0,0015 % + 5 µΩ 100 Ω 至 100 kΩ CMC 0,0012 % 100 kΩ 至 1 MΩ CMC 0,0020 % 1 MΩ 至 10 MΩ CMC 0,0070 % 10 MΩ 至 100 MΩ CMC 0,060 % KP - 09, KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"64558cf67320870a63f0ecd8","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"6","test_object":"Moc czynna prądu przemiennego, jednofazowa, trójfazowa / mierniki i źródła mocy","test_object_en":"AC active power, single-phase, three-phase / Power meters and sources","test_object_zh":"交流有功功率，单相、三相 / 功率测量仪器和功率源","test_object_cs":"Střídavý výkon činný, jednofázový, třífázový / Měřidla i zdroje výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360°","range":"od 0,02 W do 36 kW","cmc":"0,03 %"}],"parameters_en":[{"name":"1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360°","range":"0,02 W to 36 kW","cmc":"0,03 %"}],"parameters_zh":[{"name":"1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz；φ = 0° 至 360°","range":"0,02 W 至 36 kW","cmc":"0,03 %"}],"parameters_cs":[{"name":"1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz; φ = 0° až 360°","range":"0,02 W až 36 kW","cmc":"0,03 %"}],"technique":"Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym","technique_en":"Direct measurement of a standard calibrator / measurement with a standard wattmeter","technique_zh":"直接测量标准校准器 / 用标准功率表测量","technique_cs":"Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem","techniques":["Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym"],"techniques_en":["Direct measurement of a standard calibrator / measurement with a standard wattmeter"],"techniques_zh":["直接测量标准校准器 / 用标准功率表测量"],"techniques_cs":["Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,02 W do 36 kW CMC 0,03 %\nPomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego, jednofazowa, trójfazowa / mierniki i źródła mocy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,02 W do 36 kW CMC 0,03 % Střídavý výkon činný, jednofázový, třífázový / Měřidla i zdroje výkonu Kalibrace – elektrické veličiny Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem 1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz; φ = 0° až 360° 0,02 W až 36 kW CMC 0,03 % KP - 11 Moc czynna pradu przemiennego, jednofazowa, trojfazowa / mierniki i zrodla mocy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratora wzorcowego / pomiar watomierzem wzorcowym 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,02 W do 36 kW CMC 0,03 % Stridavy vykon cinny, jednofazovy, trifazovy / Meridla i zdroje vykonu Kalibrace – elektricke veliciny Prime mereni etalonoveho kalibratoru / mereni etalonovym wattmetrem 1 V az 400 V; 0,02 A az 90 A; 40 Hz az 70 Hz; φ = 0° az 360° 0,02 W az 36 kW CMC 0,03 % KP - 11","search_en":"AC active power, single-phase, three-phase / Power meters and sources Calibration – electrical quantities Direct measurement of a standard calibrator / measurement with a standard wattmeter 1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360° 0,02 W to 36 kW CMC 0,03 % KP - 11","search_zh":"交流有功功率，单相、三相 / 功率测量仪器和功率源 校准 – 电学量 直接测量标准校准器 / 用标准功率表测量 1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz；φ = 0° 至 360° 0,02 W 至 36 kW CMC 0,03 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"621c0fc73c3d9b8114909c86","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"6","test_object":"Moc czynna prądu przemiennego, jednofazowa, trójfazowa / cęgowe mierniki mocy","test_object_en":"AC active power, single-phase, three-phase / Clamp power meters","test_object_zh":"交流有功功率，单相、三相 / 钳形功率表","test_object_cs":"Střídavý výkon činný, jednofázový, třífázový / Klešťová měřidla výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360°","range":"od 0,1 W do 600 kW","cmc":"0,6 %"}],"parameters_en":[{"name":"1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360°","range":"0,1 W to 600 kW","cmc":"0,6 %"}],"parameters_zh":[{"name":"1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz；φ = 0° 至 360°","range":"0,1 W 至 600 kW","cmc":"0,6 %"}],"parameters_cs":[{"name":"1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz; φ = 0° až 360°","range":"0,1 W až 600 kW","cmc":"0,6 %"}],"technique":"Pomiar bezpośredni kalibratora wzorcowego z cewką","technique_en":"Direct measurement of a standard calibrator with a coil","technique_zh":"直接测量带线圈的标准校准器","technique_cs":"Přímé měření etalonového kalibrátoru s cívkou","techniques":["Pomiar bezpośredni kalibratora wzorcowego z cewką"],"techniques_en":["Direct measurement of a standard calibrator with a coil"],"techniques_zh":["直接测量带线圈的标准校准器"],"techniques_cs":["Přímé měření etalonového kalibrátoru s cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,1 W do 600 kW CMC 0,6 %\nPomiar bezpośredni kalibratora wzorcowego z cewką","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego, jednofazowa, trójfazowa / cęgowe mierniki mocy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratora wzorcowego z cewką 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,1 W do 600 kW CMC 0,6 % Střídavý výkon činný, jednofázový, třífázový / Klešťová měřidla výkonu Kalibrace – elektrické veličiny Přímé měření etalonového kalibrátoru s cívkou 1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz; φ = 0° až 360° 0,1 W až 600 kW CMC 0,6 % KP - 11 Moc czynna pradu przemiennego, jednofazowa, trojfazowa / cegowe mierniki mocy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratora wzorcowego z cewka 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,1 W do 600 kW CMC 0,6 % Stridavy vykon cinny, jednofazovy, trifazovy / Klestova meridla vykonu Kalibrace – elektricke veliciny Prime mereni etalonoveho kalibratoru s civkou 1 V az 400 V; 0,02 A az 90 A; 40 Hz az 70 Hz; φ = 0° az 360° 0,1 W az 600 kW CMC 0,6 % KP - 11","search_en":"AC active power, single-phase, three-phase / Clamp power meters Calibration – electrical quantities Direct measurement of a standard calibrator with a coil 1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360° 0,1 W to 600 kW CMC 0,6 % KP - 11","search_zh":"交流有功功率，单相、三相 / 钳形功率表 校准 – 电学量 直接测量带线圈的标准校准器 1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz；φ = 0° 至 360° 0,1 W 至 600 kW CMC 0,6 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d1f0b96bac64421fd834a2a","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"6","test_object":"Moc bierna prądu przemiennego, jednofazowa, trójfazowa / mierniki i źródła mocy","test_object_en":"AC reactive power, single-phase, three-phase / Power meters and sources","test_object_zh":"交流无功功率，单相、三相 / 功率测量仪器和功率源","test_object_cs":"Střídavý výkon jalový, jednofázový, třífázový / Měřidla i zdroje výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360°","range":"od 0,02 Var do 36 kVar","cmc":"0,03 %"}],"parameters_en":[{"name":"1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360°","range":"0,02 Var to 36 kVar","cmc":"0,03 %"}],"parameters_zh":[{"name":"1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz；φ = 0° 至 360°","range":"0,02 Var 至 36 kVar","cmc":"0,03 %"}],"parameters_cs":[{"name":"1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz; φ = 0° až 360°","range":"0,02 Var až 36 kVar","cmc":"0,03 %"}],"technique":"Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym","technique_en":"Direct measurement of a standard calibrator / measurement with a standard wattmeter","technique_zh":"直接测量标准校准器 / 用标准功率表测量","technique_cs":"Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem","techniques":["Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym"],"techniques_en":["Direct measurement of a standard calibrator / measurement with a standard wattmeter"],"techniques_zh":["直接测量标准校准器 / 用标准功率表测量"],"techniques_cs":["Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,02 Var do 36 kVar CMC 0,03 %\nPomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc bierna prądu przemiennego, jednofazowa, trójfazowa / mierniki i źródła mocy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,02 Var do 36 kVar CMC 0,03 % Střídavý výkon jalový, jednofázový, třífázový / Měřidla i zdroje výkonu Kalibrace – elektrické veličiny Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem 1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz; φ = 0° až 360° 0,02 Var až 36 kVar CMC 0,03 % KP - 11 Moc bierna pradu przemiennego, jednofazowa, trojfazowa / mierniki i zrodla mocy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratora wzorcowego / pomiar watomierzem wzorcowym 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,02 Var do 36 kVar CMC 0,03 % Stridavy vykon jalovy, jednofazovy, trifazovy / Meridla i zdroje vykonu Kalibrace – elektricke veliciny Prime mereni etalonoveho kalibratoru / mereni etalonovym wattmetrem 1 V az 400 V; 0,02 A az 90 A; 40 Hz az 70 Hz; φ = 0° az 360° 0,02 Var az 36 kVar CMC 0,03 % KP - 11","search_en":"AC reactive power, single-phase, three-phase / Power meters and sources Calibration – electrical quantities Direct measurement of a standard calibrator / measurement with a standard wattmeter 1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360° 0,02 Var to 36 kVar CMC 0,03 % KP - 11","search_zh":"交流无功功率，单相、三相 / 功率测量仪器和功率源 校准 – 电学量 直接测量标准校准器 / 用标准功率表测量 1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz；φ = 0° 至 360° 0,02 Var 至 36 kVar CMC 0,03 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7d608470903359e50ec9f165","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"6","test_object":"Moc bierna prądu przemiennego, jednofazowa, trójfazowa / cęgowe mierniki mocy","test_object_en":"AC reactive power, single-phase, three-phase / Clamp power meters","test_object_zh":"交流无功功率，单相、三相 / 钳形功率表","test_object_cs":"Střídavý výkon jalový, jednofázový, třífázový / Klešťová měřidla výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360°","range":"od 0,1 Var do 600 kVar","cmc":"0,6 %"}],"parameters_en":[{"name":"1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360°","range":"0,1 Var to 600 kVar","cmc":"0,6 %"}],"parameters_zh":[{"name":"1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz；φ = 0° 至 360°","range":"0,1 Var 至 600 kVar","cmc":"0,6 %"}],"parameters_cs":[{"name":"1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz; φ = 0° až 360°","range":"0,1 Var až 600 kVar","cmc":"0,6 %"}],"technique":"Pomiar bezpośredni kalibratora wzorcowego z cewką","technique_en":"Direct measurement of a standard calibrator with a coil","technique_zh":"直接测量带线圈的标准校准器","technique_cs":"Přímé měření etalonového kalibrátoru s cívkou","techniques":["Pomiar bezpośredni kalibratora wzorcowego z cewką"],"techniques_en":["Direct measurement of a standard calibrator with a coil"],"techniques_zh":["直接测量带线圈的标准校准器"],"techniques_cs":["Přímé měření etalonového kalibrátoru s cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,1 Var do 600 kVar CMC 0,6 %\nPomiar bezpośredni kalibratora wzorcowego z cewką","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc bierna prądu przemiennego, jednofazowa, trójfazowa / cęgowe mierniki mocy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratora wzorcowego z cewką 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,1 Var do 600 kVar CMC 0,6 % Střídavý výkon jalový, jednofázový, třífázový / Klešťová měřidla výkonu Kalibrace – elektrické veličiny Přímé měření etalonového kalibrátoru s cívkou 1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz; φ = 0° až 360° 0,1 Var až 600 kVar CMC 0,6 % KP - 11 Moc bierna pradu przemiennego, jednofazowa, trojfazowa / cegowe mierniki mocy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratora wzorcowego z cewka 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz; φ = 0° do 360° od 0,1 Var do 600 kVar CMC 0,6 % Stridavy vykon jalovy, jednofazovy, trifazovy / Klestova meridla vykonu Kalibrace – elektricke veliciny Prime mereni etalonoveho kalibratoru s civkou 1 V az 400 V; 0,02 A az 90 A; 40 Hz az 70 Hz; φ = 0° az 360° 0,1 Var az 600 kVar CMC 0,6 % KP - 11","search_en":"AC reactive power, single-phase, three-phase / Clamp power meters Calibration – electrical quantities Direct measurement of a standard calibrator with a coil 1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz; φ = 0° to 360° 0,1 Var to 600 kVar CMC 0,6 % KP - 11","search_zh":"交流无功功率，单相、三相 / 钳形功率表 校准 – 电学量 直接测量带线圈的标准校准器 1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz；φ = 0° 至 360° 0,1 Var 至 600 kVar CMC 0,6 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1e534538011db7ee220435b0","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"6","test_object":"Moc pozorna prądu przemiennego, jednofazowa, trójfazowa / mierniki i źródła mocy","test_object_en":"AC apparent power, single-phase, three-phase / Power meters and sources","test_object_zh":"交流视在功率，单相、三相 / 功率测量仪器和功率源","test_object_cs":"Střídavý výkon zdánlivý, jednofázový, třífázový / Měřidla i zdroje výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz","range":"od 0,02 VA do 36 kVA","cmc":"0,03 %"}],"parameters_en":[{"name":"1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz","range":"0,02 VA to 36 kVA","cmc":"0,03 %"}],"parameters_zh":[{"name":"1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz","range":"0,02 VA 至 36 kVA","cmc":"0,03 %"}],"parameters_cs":[{"name":"1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz","range":"0,02 VA až 36 kVA","cmc":"0,03 %"}],"technique":"Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym","technique_en":"Direct measurement of a standard calibrator / measurement with a standard wattmeter","technique_zh":"直接测量标准校准器 / 用标准功率表测量","technique_cs":"Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem","techniques":["Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym"],"techniques_en":["Direct measurement of a standard calibrator / measurement with a standard wattmeter"],"techniques_zh":["直接测量标准校准器 / 用标准功率表测量"],"techniques_cs":["Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz od 0,02 VA do 36 kVA CMC 0,03 %\nPomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc pozorna prądu przemiennego, jednofazowa, trójfazowa / mierniki i źródła mocy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz od 0,02 VA do 36 kVA CMC 0,03 % Střídavý výkon zdánlivý, jednofázový, třífázový / Měřidla i zdroje výkonu Kalibrace – elektrické veličiny Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem 1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz 0,02 VA až 36 kVA CMC 0,03 % KP - 11 Moc pozorna pradu przemiennego, jednofazowa, trojfazowa / mierniki i zrodla mocy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratora wzorcowego / pomiar watomierzem wzorcowym 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz od 0,02 VA do 36 kVA CMC 0,03 % Stridavy vykon zdanlivy, jednofazovy, trifazovy / Meridla i zdroje vykonu Kalibrace – elektricke veliciny Prime mereni etalonoveho kalibratoru / mereni etalonovym wattmetrem 1 V az 400 V; 0,02 A az 90 A; 40 Hz az 70 Hz 0,02 VA az 36 kVA CMC 0,03 % KP - 11","search_en":"AC apparent power, single-phase, three-phase / Power meters and sources Calibration – electrical quantities Direct measurement of a standard calibrator / measurement with a standard wattmeter 1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz 0,02 VA to 36 kVA CMC 0,03 % KP - 11","search_zh":"交流视在功率，单相、三相 / 功率测量仪器和功率源 校准 – 电学量 直接测量标准校准器 / 用标准功率表测量 1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz 0,02 VA 至 36 kVA CMC 0,03 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9cae282355064cd0a909bfc9","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"6","test_object":"Moc pozorna prądu przemiennego, jednofazowa, trójfazowa / cęgowe mierniki mocy","test_object_en":"AC apparent power, single-phase, three-phase / Clamp power meters","test_object_zh":"交流视在功率，单相、三相 / 钳形功率表","test_object_cs":"Střídavý výkon zdánlivý, jednofázový, třífázový / Klešťová měřidla výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz","range":"od 0,1 VA do 600 kVA","cmc":"0,8 %"}],"parameters_en":[{"name":"1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz","range":"0,1 VA to 600 kVA","cmc":"0,8 %"}],"parameters_zh":[{"name":"1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz","range":"0,1 VA 至 600 kVA","cmc":"0,8 %"}],"parameters_cs":[{"name":"1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz","range":"0,1 VA až 600 kVA","cmc":"0,8 %"}],"technique":"Pomiar bezpośredni kalibratora wzorcowego z cewką","technique_en":"Direct measurement of a standard calibrator with a coil","technique_zh":"直接测量带线圈的标准校准器","technique_cs":"Přímé měření etalonového kalibrátoru s cívkou","techniques":["Pomiar bezpośredni kalibratora wzorcowego z cewką"],"techniques_en":["Direct measurement of a standard calibrator with a coil"],"techniques_zh":["直接测量带线圈的标准校准器"],"techniques_cs":["Přímé měření etalonového kalibrátoru s cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz od 0,1 VA do 600 kVA CMC 0,8 %\nPomiar bezpośredni kalibratora wzorcowego z cewką","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc pozorna prądu przemiennego, jednofazowa, trójfazowa / cęgowe mierniki mocy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratora wzorcowego z cewką 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz od 0,1 VA do 600 kVA CMC 0,8 % Střídavý výkon zdánlivý, jednofázový, třífázový / Klešťová měřidla výkonu Kalibrace – elektrické veličiny Přímé měření etalonového kalibrátoru s cívkou 1 V až 400 V; 0,02 A až 90 A; 40 Hz až 70 Hz 0,1 VA až 600 kVA CMC 0,8 % KP - 11 Moc pozorna pradu przemiennego, jednofazowa, trojfazowa / cegowe mierniki mocy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratora wzorcowego z cewka 1 V do 400 V; 0,02 A do 90 A; 40 Hz do 70 Hz od 0,1 VA do 600 kVA CMC 0,8 % Stridavy vykon zdanlivy, jednofazovy, trifazovy / Klestova meridla vykonu Kalibrace – elektricke veliciny Prime mereni etalonoveho kalibratoru s civkou 1 V az 400 V; 0,02 A az 90 A; 40 Hz az 70 Hz 0,1 VA az 600 kVA CMC 0,8 % KP - 11","search_en":"AC apparent power, single-phase, three-phase / Clamp power meters Calibration – electrical quantities Direct measurement of a standard calibrator with a coil 1 V to 400 V; 0.02 A to 90 A; 40 Hz to 70 Hz 0,1 VA to 600 kVA CMC 0,8 % KP - 11","search_zh":"交流视在功率，单相、三相 / 钳形功率表 校准 – 电学量 直接测量带线圈的标准校准器 1 V 至 400 V；0,02 A 至 90 A；40 Hz 至 70 Hz 0,1 VA 至 600 kVA CMC 0,8 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1170c84bde13efe23d1280a","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"7","test_object":"Moc prądu stałego, jednofazowa, trójfazowa / mierniki i źródła mocy","test_object_en":"DC power, single-phase, three-phase / Power meters and sources","test_object_zh":"直流功率，单相、三相 / 功率测量仪器和功率源","test_object_cs":"Stejnosměrný výkon jednofázový, třífázový / Měřidla a zdroje výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V; 0,02 A do 90 A","range":"od 0,1 W do 36 kW","cmc":"0,06 %"}],"parameters_en":[{"name":"1 V to 400 V; 0.02 A to 90 A","range":"0,1 W to 36 kW","cmc":"0,06 %"}],"parameters_zh":[{"name":"1 V 至 400 V；0,02 A 至 90 A","range":"0,1 W 至 36 kW","cmc":"0,06 %"}],"parameters_cs":[{"name":"1 V až 400 V; 0,02 A až 90 A","range":"0,1 W až 36 kW","cmc":"0,06 %"}],"technique":"Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym","technique_en":"Direct measurement of a standard calibrator / measurement with a standard wattmeter","technique_zh":"直接测量标准校准器 / 用标准功率表测量","technique_cs":"Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem","techniques":["Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym"],"techniques_en":["Direct measurement of a standard calibrator / measurement with a standard wattmeter"],"techniques_zh":["直接测量标准校准器 / 用标准功率表测量"],"techniques_cs":["Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V; 0,02 A do 90 A od 0,1 W do 36 kW CMC 0,06 %\nPomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego, jednofazowa, trójfazowa / mierniki i źródła mocy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratora wzorcowego / pomiar watomierzem wzorcowym 1 V do 400 V; 0,02 A do 90 A od 0,1 W do 36 kW CMC 0,06 % Stejnosměrný výkon jednofázový, třífázový / Měřidla a zdroje výkonu Kalibrace – elektrické veličiny Přímé měření etalonového kalibrátoru / měření etalonovým wattmetrem 1 V až 400 V; 0,02 A až 90 A 0,1 W až 36 kW CMC 0,06 % KP - 11 Moc pradu stalego, jednofazowa, trojfazowa / mierniki i zrodla mocy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratora wzorcowego / pomiar watomierzem wzorcowym 1 V do 400 V; 0,02 A do 90 A od 0,1 W do 36 kW CMC 0,06 % Stejnosmerny vykon jednofazovy, trifazovy / Meridla a zdroje vykonu Kalibrace – elektricke veliciny Prime mereni etalonoveho kalibratoru / mereni etalonovym wattmetrem 1 V az 400 V; 0,02 A az 90 A 0,1 W az 36 kW CMC 0,06 % KP - 11","search_en":"DC power, single-phase, three-phase / Power meters and sources Calibration – electrical quantities Direct measurement of a standard calibrator / measurement with a standard wattmeter 1 V to 400 V; 0.02 A to 90 A 0,1 W to 36 kW CMC 0,06 % KP - 11","search_zh":"直流功率，单相、三相 / 功率测量仪器和功率源 校准 – 电学量 直接测量标准校准器 / 用标准功率表测量 1 V 至 400 V；0,02 A 至 90 A 0,1 W 至 36 kW CMC 0,06 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8bfe659edc1ac3e299bc2a5e","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"7","test_object":"Moc prądu stałego, jednofazowa, trójfazowa / cęgowe mierniki mocy","test_object_en":"DC power, single-phase, three-phase / Clamp power meters","test_object_zh":"直流功率，单相、三相 / 钳形功率表","test_object_cs":"Stejnosměrný výkon jednofázový, třífázový / Klešťová měřidla výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V; 0,02 A do 90 A","range":"od 0,1 W do 600 kW","cmc":"0,8 %"}],"parameters_en":[{"name":"1 V to 400 V; 0.02 A to 90 A","range":"0,1 W to 600 kW","cmc":"0,8 %"}],"parameters_zh":[{"name":"1 V 至 400 V；0,02 A 至 90 A","range":"0,1 W 至 600 kW","cmc":"0,8 %"}],"parameters_cs":[{"name":"1 V až 400 V; 0,02 A až 90 A","range":"0,1 W až 600 kW","cmc":"0,8 %"}],"technique":"Pomiar bezpośredni kalibratora wzorcowego z cewką","technique_en":"Direct measurement of a standard calibrator with a coil","technique_zh":"直接测量带线圈的标准校准器","technique_cs":"Přímé měření etalonového kalibrátoru s cívkou","techniques":["Pomiar bezpośredni kalibratora wzorcowego z cewką"],"techniques_en":["Direct measurement of a standard calibrator with a coil"],"techniques_zh":["直接测量带线圈的标准校准器"],"techniques_cs":["Přímé měření etalonového kalibrátoru s cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V; 0,02 A do 90 A od 0,1 W do 600 kW CMC 0,8 %\nPomiar bezpośredni kalibratora wzorcowego z cewką","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego, jednofazowa, trójfazowa / cęgowe mierniki mocy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni kalibratora wzorcowego z cewką 1 V do 400 V; 0,02 A do 90 A od 0,1 W do 600 kW CMC 0,8 % Stejnosměrný výkon jednofázový, třífázový / Klešťová měřidla výkonu Kalibrace – elektrické veličiny Přímé měření etalonového kalibrátoru s cívkou 1 V až 400 V; 0,02 A až 90 A 0,1 W až 600 kW CMC 0,8 % KP - 11 Moc pradu stalego, jednofazowa, trojfazowa / cegowe mierniki mocy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni kalibratora wzorcowego z cewka 1 V do 400 V; 0,02 A do 90 A od 0,1 W do 600 kW CMC 0,8 % Stejnosmerny vykon jednofazovy, trifazovy / Klestova meridla vykonu Kalibrace – elektricke veliciny Prime mereni etalonoveho kalibratoru s civkou 1 V az 400 V; 0,02 A az 90 A 0,1 W az 600 kW CMC 0,8 % KP - 11","search_en":"DC power, single-phase, three-phase / Clamp power meters Calibration – electrical quantities Direct measurement of a standard calibrator with a coil 1 V to 400 V; 0.02 A to 90 A 0,1 W to 600 kW CMC 0,8 % KP - 11","search_zh":"直流功率，单相、三相 / 钳形功率表 校准 – 电学量 直接测量带线圈的标准校准器 1 V 至 400 V；0,02 A 至 90 A 0,1 W 至 600 kW CMC 0,8 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b214e4867dc0ce46b0c927eb","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"8","test_object":"Składowa podstawowa / mierniki harmonicznych i interharmonicznych napięcia","test_object_en":"Fundamental component / Meters of harmonic and interharmonic voltage components","test_object_zh":"基波分量 / 谐波和间谐波电压分量测量仪器","test_object_cs":"Základní složka / Měřidla harmonických a interharmonických složek napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 10 V do 360 V","cmc":"0,02 %"}],"parameters_en":[{"name":"50 Hz","range":"10 V to 360 V","cmc":"0,02 %"}],"parameters_zh":[{"name":"50 Hz","range":"10 V 至 360 V","cmc":"0,02 %"}],"parameters_cs":[{"name":"50 Hz","range":"10 V až 360 V","cmc":"0,02 %"}],"technique":"Porównanie z watomierzem wzorcowym","technique_en":"Comparison with a standard wattmeter","technique_zh":"与标准功率表比较","technique_cs":"Porovnání s etalonovým W-metrem","techniques":["Porównanie z watomierzem wzorcowym"],"techniques_en":["Comparison with a standard wattmeter"],"techniques_zh":["与标准功率表比较"],"techniques_cs":["Porovnání s etalonovým W-metrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 10 V do 360 V CMC 0,02 %\nPorównanie z watomierzem wzorcowym","reference":"KP - 14","norm_bases":["KP - 14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Składowa podstawowa / mierniki harmonicznych i interharmonicznych napięcia Wzorcowanie – wielkości elektryczne Porównanie z watomierzem wzorcowym 50 Hz od 10 V do 360 V CMC 0,02 % Základní složka / Měřidla harmonických a interharmonických složek napětí Kalibrace – elektrické veličiny Porovnání s etalonovým W-metrem 50 Hz 10 V až 360 V CMC 0,02 % KP - 14 Skladowa podstawowa / mierniki harmonicznych i interharmonicznych napiecia Wzorcowanie – wielkosci elektryczne Porownanie z watomierzem wzorcowym 50 Hz od 10 V do 360 V CMC 0,02 % Zakladni slozka / Meridla harmonickych a interharmonickych slozek napeti Kalibrace – elektricke veliciny Porovnani s etalonovym W-metrem 50 Hz 10 V az 360 V CMC 0,02 % KP - 14","search_en":"Fundamental component / Meters of harmonic and interharmonic voltage components Calibration – electrical quantities Comparison with a standard wattmeter 50 Hz 10 V to 360 V CMC 0,02 % KP - 14","search_zh":"基波分量 / 谐波和间谐波电压分量测量仪器 校准 – 电学量 与标准功率表比较 50 Hz 10 V 至 360 V CMC 0,02 % KP - 14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3f18c0368714dda3ab08a6fd","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"8","test_object":"Amplituda wyższych składowych sygnału / mierniki harmonicznych i interharmonicznych napięcia","test_object_en":"Amplitude of higher signal components / Meters of harmonic and interharmonic voltage components","test_object_zh":"信号高次分量幅值 / 谐波和间谐波电压分量测量仪器","test_object_cs":"Amplituda vyšších složek signálu / Měřidla harmonických a interharmonických složek napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"15 Hz do 1 kHz","range":"od 0 %·U₁ do 30 %·U₁","cmc":"0,05 %"},{"name":"1 kHz do 2,5 kHz","range":"od 0 %·U₁ do 30 %·U₁","cmc":"0,1 %"}],"parameters_en":[{"name":"15 Hz to 1 kHz","range":"0 %·U₁ to 30 %·U₁","cmc":"0,05 %"},{"name":"1 kHz to 2,5 kHz","range":"0 %·U₁ to 30 %·U₁","cmc":"0,1 %"}],"parameters_zh":[{"name":"15 Hz 至 1 kHz","range":"0 %·U₁ 至 30 %·U₁","cmc":"0,05 %"},{"name":"1 kHz 至 2,5 kHz","range":"0 %·U₁ 至 30 %·U₁","cmc":"0,1 %"}],"parameters_cs":[{"name":"15 Hz až 1 kHz","range":"0 %·U₁ až 30 %·U₁","cmc":"0,05 %"},{"name":"1 kHz až 2,5 kHz","range":"0 %·U₁ až 30 %·U₁","cmc":"0,1 %"}],"technique":"Porównanie z watomierzem wzorcowym","technique_en":"Comparison with a standard wattmeter","technique_zh":"与标准功率表比较","technique_cs":"Porovnání s etalonovým W-metrem","techniques":["Porównanie z watomierzem wzorcowym"],"techniques_en":["Comparison with a standard wattmeter"],"techniques_zh":["与标准功率表比较"],"techniques_cs":["Porovnání s etalonovým W-metrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n15 Hz do 1 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,05 %\n1 kHz do 2,5 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,1 %\nPorównanie z watomierzem wzorcowym","reference":"KP - 14","norm_bases":["KP - 14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Amplituda wyższych składowych sygnału / mierniki harmonicznych i interharmonicznych napięcia Wzorcowanie – wielkości elektryczne Porównanie z watomierzem wzorcowym 15 Hz do 1 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,05 % 1 kHz do 2,5 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,1 % Amplituda vyšších složek signálu / Měřidla harmonických a interharmonických složek napětí Kalibrace – elektrické veličiny Porovnání s etalonovým W-metrem 15 Hz až 1 kHz 0 %·U₁ až 30 %·U₁ CMC 0,05 % 1 kHz až 2,5 kHz 0 %·U₁ až 30 %·U₁ CMC 0,1 % KP - 14 Amplituda wyzszych skladowych sygnalu / mierniki harmonicznych i interharmonicznych napiecia Wzorcowanie – wielkosci elektryczne Porownanie z watomierzem wzorcowym 15 Hz do 1 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,05 % 1 kHz do 2,5 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,1 % Amplituda vyssich slozek signalu / Meridla harmonickych a interharmonickych slozek napeti Kalibrace – elektricke veliciny Porovnani s etalonovym W-metrem 15 Hz az 1 kHz 0 %·U₁ az 30 %·U₁ CMC 0,05 % 1 kHz az 2,5 kHz 0 %·U₁ az 30 %·U₁ CMC 0,1 % KP - 14","search_en":"Amplitude of higher signal components / Meters of harmonic and interharmonic voltage components Calibration – electrical quantities Comparison with a standard wattmeter 15 Hz to 1 kHz 0 %·U₁ to 30 %·U₁ CMC 0,05 % 1 kHz to 2,5 kHz 0 %·U₁ to 30 %·U₁ CMC 0,1 % KP - 14","search_zh":"信号高次分量幅值 / 谐波和间谐波电压分量测量仪器 校准 – 电学量 与标准功率表比较 15 Hz 至 1 kHz 0 %·U₁ 至 30 %·U₁ CMC 0,05 % 1 kHz 至 2,5 kHz 0 %·U₁ 至 30 %·U₁ CMC 0,1 % KP - 14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b41ab25dc87420fb1ab47cf2","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"8","test_object":"Składowa podstawowa / mierniki harmonicznych i interharmonicznych prądu","test_object_en":"Fundamental component / Meters of harmonic and interharmonic current components","test_object_zh":"基波分量 / 谐波和间谐波电流分量测量仪器","test_object_cs":"Základní složka / Měřidla harmonických a interharmonických složek proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 0,01 A do 20 A","cmc":"0,02 %"}],"parameters_en":[{"name":"50 Hz","range":"0,01 A to 20 A","cmc":"0,02 %"}],"parameters_zh":[{"name":"50 Hz","range":"0,01 A 至 20 A","cmc":"0,02 %"}],"parameters_cs":[{"name":"50 Hz","range":"0,01 A až 20 A","cmc":"0,02 %"}],"technique":"Porównanie z watomierzem wzorcowym","technique_en":"Comparison with a standard wattmeter","technique_zh":"与标准功率表比较","technique_cs":"Porovnání s etalonovým W-metrem","techniques":["Porównanie z watomierzem wzorcowym"],"techniques_en":["Comparison with a standard wattmeter"],"techniques_zh":["与标准功率表比较"],"techniques_cs":["Porovnání s etalonovým W-metrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 0,01 A do 20 A CMC 0,02 %\nPorównanie z watomierzem wzorcowym","reference":"KP - 14","norm_bases":["KP - 14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Składowa podstawowa / mierniki harmonicznych i interharmonicznych prądu Wzorcowanie – wielkości elektryczne Porównanie z watomierzem wzorcowym 50 Hz od 0,01 A do 20 A CMC 0,02 % Základní složka / Měřidla harmonických a interharmonických složek proudu Kalibrace – elektrické veličiny Porovnání s etalonovým W-metrem 50 Hz 0,01 A až 20 A CMC 0,02 % KP - 14 Skladowa podstawowa / mierniki harmonicznych i interharmonicznych pradu Wzorcowanie – wielkosci elektryczne Porownanie z watomierzem wzorcowym 50 Hz od 0,01 A do 20 A CMC 0,02 % Zakladni slozka / Meridla harmonickych a interharmonickych slozek proudu Kalibrace – elektricke veliciny Porovnani s etalonovym W-metrem 50 Hz 0,01 A az 20 A CMC 0,02 % KP - 14","search_en":"Fundamental component / Meters of harmonic and interharmonic current components Calibration – electrical quantities Comparison with a standard wattmeter 50 Hz 0,01 A to 20 A CMC 0,02 % KP - 14","search_zh":"基波分量 / 谐波和间谐波电流分量测量仪器 校准 – 电学量 与标准功率表比较 50 Hz 0,01 A 至 20 A CMC 0,02 % KP - 14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0851551b34df2c145ed88ad9","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"8","test_object":"Amplituda wyższych składowych sygnału / mierniki harmonicznych i interharmonicznych prądu","test_object_en":"Amplitude of higher signal components / Meters of harmonic and interharmonic current components","test_object_zh":"信号高次分量幅值 / 谐波和间谐波电流分量测量仪器","test_object_cs":"Amplituda vyšších složek signálu / Měřidla harmonických a interharmonických složek proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"15 Hz do 2,5 Hz","range":"od 0 %·I₁ do 30 %·I₁","cmc":"0,1 %"}],"parameters_en":[{"name":"15 Hz to 2,5 Hz","range":"0 %·I₁ to 30 %·I₁","cmc":"0,1 %"}],"parameters_zh":[{"name":"15 Hz 至 2,5 Hz","range":"0 %·I₁ 至 30 %·I₁","cmc":"0,1 %"}],"parameters_cs":[{"name":"15 Hz až 2,5 Hz","range":"0 %·I₁ až 30 %·I₁","cmc":"0,1 %"}],"technique":"Porównanie z watomierzem wzorcowym","technique_en":"Comparison with a standard wattmeter","technique_zh":"与标准功率表比较","technique_cs":"Porovnání s etalonovým W-metrem","techniques":["Porównanie z watomierzem wzorcowym"],"techniques_en":["Comparison with a standard wattmeter"],"techniques_zh":["与标准功率表比较"],"techniques_cs":["Porovnání s etalonovým W-metrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n15 Hz do 2,5 Hz od 0 %·I₁ do 30 %·I₁ CMC 0,1 %\nPorównanie z watomierzem wzorcowym","reference":"KP - 14","norm_bases":["KP - 14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Amplituda wyższych składowych sygnału / mierniki harmonicznych i interharmonicznych prądu Wzorcowanie – wielkości elektryczne Porównanie z watomierzem wzorcowym 15 Hz do 2,5 Hz od 0 %·I₁ do 30 %·I₁ CMC 0,1 % Amplituda vyšších složek signálu / Měřidla harmonických a interharmonických složek proudu Kalibrace – elektrické veličiny Porovnání s etalonovým W-metrem 15 Hz až 2,5 Hz 0 %·I₁ až 30 %·I₁ CMC 0,1 % KP - 14 Amplituda wyzszych skladowych sygnalu / mierniki harmonicznych i interharmonicznych pradu Wzorcowanie – wielkosci elektryczne Porownanie z watomierzem wzorcowym 15 Hz do 2,5 Hz od 0 %·I₁ do 30 %·I₁ CMC 0,1 % Amplituda vyssich slozek signalu / Meridla harmonickych a interharmonickych slozek proudu Kalibrace – elektricke veliciny Porovnani s etalonovym W-metrem 15 Hz az 2,5 Hz 0 %·I₁ az 30 %·I₁ CMC 0,1 % KP - 14","search_en":"Amplitude of higher signal components / Meters of harmonic and interharmonic current components Calibration – electrical quantities Comparison with a standard wattmeter 15 Hz to 2,5 Hz 0 %·I₁ to 30 %·I₁ CMC 0,1 % KP - 14","search_zh":"信号高次分量幅值 / 谐波和间谐波电流分量测量仪器 校准 – 电学量 与标准功率表比较 15 Hz 至 2,5 Hz 0 %·I₁ 至 30 %·I₁ CMC 0,1 % KP - 14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"09fe7fbdb2eb5c3f5801a78e","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"8","test_object":"Składowa podstawowa / źródła harmonicznych i interharmonicznych napięcia","test_object_en":"Fundamental component / Sources of harmonic and interharmonic voltage components","test_object_zh":"基波分量 / 谐波和间谐波电压分量源","test_object_cs":"Základní složka / Zdroje harmonických a interharmonických složek napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 10 V do 360 V","cmc":"0,02 %"}],"parameters_en":[{"name":"50 Hz","range":"10 V to 360 V","cmc":"0,02 %"}],"parameters_zh":[{"name":"50 Hz","range":"10 V 至 360 V","cmc":"0,02 %"}],"parameters_cs":[{"name":"50 Hz","range":"10 V až 360 V","cmc":"0,02 %"}],"technique":"Pomiar bezpośredni watomierzem wzorcowym","technique_en":"Direct measurement with a standard wattmeter","technique_zh":"用标准功率表直接测量","technique_cs":"Přímé měření etalonovým W-metrem","techniques":["Pomiar bezpośredni watomierzem wzorcowym"],"techniques_en":["Direct measurement with a standard wattmeter"],"techniques_zh":["用标准功率表直接测量"],"techniques_cs":["Přímé měření etalonovým W-metrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 10 V do 360 V CMC 0,02 %\nPomiar bezpośredni watomierzem wzorcowym","reference":"KP - 14","norm_bases":["KP - 14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Składowa podstawowa / źródła harmonicznych i interharmonicznych napięcia Wzorcowanie – wielkości elektryczne Pomiar bezpośredni watomierzem wzorcowym 50 Hz od 10 V do 360 V CMC 0,02 % Základní složka / Zdroje harmonických a interharmonických složek napětí Kalibrace – elektrické veličiny Přímé měření etalonovým W-metrem 50 Hz 10 V až 360 V CMC 0,02 % KP - 14 Skladowa podstawowa / zrodla harmonicznych i interharmonicznych napiecia Wzorcowanie – wielkosci elektryczne Pomiar bezposredni watomierzem wzorcowym 50 Hz od 10 V do 360 V CMC 0,02 % Zakladni slozka / Zdroje harmonickych a interharmonickych slozek napeti Kalibrace – elektricke veliciny Prime mereni etalonovym W-metrem 50 Hz 10 V az 360 V CMC 0,02 % KP - 14","search_en":"Fundamental component / Sources of harmonic and interharmonic voltage components Calibration – electrical quantities Direct measurement with a standard wattmeter 50 Hz 10 V to 360 V CMC 0,02 % KP - 14","search_zh":"基波分量 / 谐波和间谐波电压分量源 校准 – 电学量 用标准功率表直接测量 50 Hz 10 V 至 360 V CMC 0,02 % KP - 14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b1175c3d3a44f9b6ebf52bd4","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"8","test_object":"Amplituda wyższych składowych sygnału / źródła harmonicznych i interharmonicznych napięcia","test_object_en":"Amplitude of higher signal components / Sources of harmonic and interharmonic voltage components","test_object_zh":"信号高次分量幅值 / 谐波和间谐波电压分量源","test_object_cs":"Amplituda vyšších složek signálu / Zdroje harmonických a interharmonických složek napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"15 Hz do 1 kHz","range":"od 0 %·U₁ do 30 %·U₁","cmc":"0,05 %"},{"name":"1 kHz do 2,5 kHz","range":"od 0 %·U₁ do 30 %·U₁","cmc":"0,1 %"}],"parameters_en":[{"name":"15 Hz to 1 kHz","range":"0 %·U₁ to 30 %·U₁","cmc":"0,05 %"},{"name":"1 kHz to 2,5 kHz","range":"0 %·U₁ to 30 %·U₁","cmc":"0,1 %"}],"parameters_zh":[{"name":"15 Hz 至 1 kHz","range":"0 %·U₁ 至 30 %·U₁","cmc":"0,05 %"},{"name":"1 kHz 至 2,5 kHz","range":"0 %·U₁ 至 30 %·U₁","cmc":"0,1 %"}],"parameters_cs":[{"name":"15 Hz až 1 kHz","range":"0 %·U₁ až 30 %·U₁","cmc":"0,05 %"},{"name":"1 kHz až 2,5 kHz","range":"0 %·U₁ až 30 %·U₁","cmc":"0,1 %"}],"technique":"Pomiar bezpośredni watomierzem wzorcowym","technique_en":"Direct measurement with a standard wattmeter","technique_zh":"用标准功率表直接测量","technique_cs":"Přímé měření etalonovým W-metrem","techniques":["Pomiar bezpośredni watomierzem wzorcowym"],"techniques_en":["Direct measurement with a standard wattmeter"],"techniques_zh":["用标准功率表直接测量"],"techniques_cs":["Přímé měření etalonovým W-metrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n15 Hz do 1 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,05 %\n1 kHz do 2,5 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,1 %\nPomiar bezpośredni watomierzem wzorcowym","reference":"KP - 14","norm_bases":["KP - 14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Amplituda wyższych składowych sygnału / źródła harmonicznych i interharmonicznych napięcia Wzorcowanie – wielkości elektryczne Pomiar bezpośredni watomierzem wzorcowym 15 Hz do 1 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,05 % 1 kHz do 2,5 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,1 % Amplituda vyšších složek signálu / Zdroje harmonických a interharmonických složek napětí Kalibrace – elektrické veličiny Přímé měření etalonovým W-metrem 15 Hz až 1 kHz 0 %·U₁ až 30 %·U₁ CMC 0,05 % 1 kHz až 2,5 kHz 0 %·U₁ až 30 %·U₁ CMC 0,1 % KP - 14 Amplituda wyzszych skladowych sygnalu / zrodla harmonicznych i interharmonicznych napiecia Wzorcowanie – wielkosci elektryczne Pomiar bezposredni watomierzem wzorcowym 15 Hz do 1 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,05 % 1 kHz do 2,5 kHz od 0 %·U₁ do 30 %·U₁ CMC 0,1 % Amplituda vyssich slozek signalu / Zdroje harmonickych a interharmonickych slozek napeti Kalibrace – elektricke veliciny Prime mereni etalonovym W-metrem 15 Hz az 1 kHz 0 %·U₁ az 30 %·U₁ CMC 0,05 % 1 kHz az 2,5 kHz 0 %·U₁ az 30 %·U₁ CMC 0,1 % KP - 14","search_en":"Amplitude of higher signal components / Sources of harmonic and interharmonic voltage components Calibration – electrical quantities Direct measurement with a standard wattmeter 15 Hz to 1 kHz 0 %·U₁ to 30 %·U₁ CMC 0,05 % 1 kHz to 2,5 kHz 0 %·U₁ to 30 %·U₁ CMC 0,1 % KP - 14","search_zh":"信号高次分量幅值 / 谐波和间谐波电压分量源 校准 – 电学量 用标准功率表直接测量 15 Hz 至 1 kHz 0 %·U₁ 至 30 %·U₁ CMC 0,05 % 1 kHz 至 2,5 kHz 0 %·U₁ 至 30 %·U₁ CMC 0,1 % KP - 14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9238216cf68e1d135c502346","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"8","test_object":"Składowa podstawowa / źródła harmonicznych i interharmonicznych prądu","test_object_en":"Fundamental component / Sources of harmonic and interharmonic current components","test_object_zh":"基波分量 / 谐波和间谐波电流分量源","test_object_cs":"Základní složka / Zdroje harmonických a interharmonických složek proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 0,01 A do 20 A","cmc":"0,02 %"}],"parameters_en":[{"name":"50 Hz","range":"0,01 A to 20 A","cmc":"0,02 %"}],"parameters_zh":[{"name":"50 Hz","range":"0,01 A 至 20 A","cmc":"0,02 %"}],"parameters_cs":[{"name":"50 Hz","range":"0,01 A až 20 A","cmc":"0,02 %"}],"technique":"Pomiar bezpośredni watomierzem wzorcowym","technique_en":"Direct measurement with a standard wattmeter","technique_zh":"用标准功率表直接测量","technique_cs":"Přímé měření etalonovým W-metrem","techniques":["Pomiar bezpośredni watomierzem wzorcowym"],"techniques_en":["Direct measurement with a standard wattmeter"],"techniques_zh":["用标准功率表直接测量"],"techniques_cs":["Přímé měření etalonovým W-metrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 0,01 A do 20 A CMC 0,02 %\nPomiar bezpośredni watomierzem wzorcowym","reference":"KP - 14","norm_bases":["KP - 14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Składowa podstawowa / źródła harmonicznych i interharmonicznych prądu Wzorcowanie – wielkości elektryczne Pomiar bezpośredni watomierzem wzorcowym 50 Hz od 0,01 A do 20 A CMC 0,02 % Základní složka / Zdroje harmonických a interharmonických složek proudu Kalibrace – elektrické veličiny Přímé měření etalonovým W-metrem 50 Hz 0,01 A až 20 A CMC 0,02 % KP - 14 Skladowa podstawowa / zrodla harmonicznych i interharmonicznych pradu Wzorcowanie – wielkosci elektryczne Pomiar bezposredni watomierzem wzorcowym 50 Hz od 0,01 A do 20 A CMC 0,02 % Zakladni slozka / Zdroje harmonickych a interharmonickych slozek proudu Kalibrace – elektricke veliciny Prime mereni etalonovym W-metrem 50 Hz 0,01 A az 20 A CMC 0,02 % KP - 14","search_en":"Fundamental component / Sources of harmonic and interharmonic current components Calibration – electrical quantities Direct measurement with a standard wattmeter 50 Hz 0,01 A to 20 A CMC 0,02 % KP - 14","search_zh":"基波分量 / 谐波和间谐波电流分量源 校准 – 电学量 用标准功率表直接测量 50 Hz 0,01 A 至 20 A CMC 0,02 % KP - 14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d8774691bd2b7cab1fe95aa6","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"8","test_object":"Amplituda wyższych składowych sygnału / źródła harmonicznych i interharmonicznych prądu","test_object_en":"Amplitude of higher signal components / Sources of harmonic and interharmonic current components","test_object_zh":"信号高次分量幅值 / 谐波和间谐波电流分量源","test_object_cs":"Amplituda vyšších složek signálu / Zdroje harmonických a interharmonických složek proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"15 Hz do 2,5 kHz","range":"od 0 %·I₁ do 30 %·I₁","cmc":"0,1 %"}],"parameters_en":[{"name":"15 Hz to 2,5 kHz","range":"0 %·I₁ to 30 %·I₁","cmc":"0,1 %"}],"parameters_zh":[{"name":"15 Hz 至 2,5 kHz","range":"0 %·I₁ 至 30 %·I₁","cmc":"0,1 %"}],"parameters_cs":[{"name":"15 Hz až 2,5 kHz","range":"0 %·I₁ až 30 %·I₁","cmc":"0,1 %"}],"technique":"Pomiar bezpośredni watomierzem wzorcowym","technique_en":"Direct measurement with a standard wattmeter","technique_zh":"用标准功率表直接测量","technique_cs":"Přímé měření etalonovým W-metrem","techniques":["Pomiar bezpośredni watomierzem wzorcowym"],"techniques_en":["Direct measurement with a standard wattmeter"],"techniques_zh":["用标准功率表直接测量"],"techniques_cs":["Přímé měření etalonovým W-metrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n15 Hz do 2,5 kHz od 0 %·I₁ do 30 %·I₁ CMC 0,1 %\nPomiar bezpośredni watomierzem wzorcowym","reference":"KP - 14","norm_bases":["KP - 14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Amplituda wyższych składowych sygnału / źródła harmonicznych i interharmonicznych prądu Wzorcowanie – wielkości elektryczne Pomiar bezpośredni watomierzem wzorcowym 15 Hz do 2,5 kHz od 0 %·I₁ do 30 %·I₁ CMC 0,1 % Amplituda vyšších složek signálu / Zdroje harmonických a interharmonických složek proudu Kalibrace – elektrické veličiny Přímé měření etalonovým W-metrem 15 Hz až 2,5 kHz 0 %·I₁ až 30 %·I₁ CMC 0,1 % KP - 14 Amplituda wyzszych skladowych sygnalu / zrodla harmonicznych i interharmonicznych pradu Wzorcowanie – wielkosci elektryczne Pomiar bezposredni watomierzem wzorcowym 15 Hz do 2,5 kHz od 0 %·I₁ do 30 %·I₁ CMC 0,1 % Amplituda vyssich slozek signalu / Zdroje harmonickych a interharmonickych slozek proudu Kalibrace – elektricke veliciny Prime mereni etalonovym W-metrem 15 Hz az 2,5 kHz 0 %·I₁ az 30 %·I₁ CMC 0,1 % KP - 14","search_en":"Amplitude of higher signal components / Sources of harmonic and interharmonic current components Calibration – electrical quantities Direct measurement with a standard wattmeter 15 Hz to 2,5 kHz 0 %·I₁ to 30 %·I₁ CMC 0,1 % KP - 14","search_zh":"信号高次分量幅值 / 谐波和间谐波电流分量源 校准 – 电学量 用标准功率表直接测量 15 Hz 至 2,5 kHz 0 %·I₁ 至 30 %·I₁ CMC 0,1 % KP - 14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d6153dc9762ee134c375be12","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"9","test_object":"Migotanie (flicker) / mierniki","test_object_en":"Flicker / Meters","test_object_zh":"闪变 / 测量仪器","test_object_cs":"Flikr / Měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000","range":"od 0,5 ·Pₛₜ do 6 ·Pₛₜ","cmc":"0,014·Pₛₜ"}],"parameters_en":[{"name":"230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000","range":"0,5 ·Pₛₜ to 6 ·Pₛₜ","cmc":"0,014·Pₛₜ"}],"parameters_zh":[{"name":"230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000","range":"0,5 ·Pₛₜ 至 6 ·Pₛₜ","cmc":"0,014·Pₛₜ"}],"parameters_cs":[{"name":"230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000","range":"0,5 ·Pₛₜ až 6 ·Pₛₜ","cmc":"0,014·Pₛₜ"}],"technique":"Porównanie z watomierzem wzorcowym","technique_en":"Comparison with a standard wattmeter","technique_zh":"与标准功率表比较","technique_cs":"Porovnání s etalonovým wattmetrem","techniques":["Porównanie z watomierzem wzorcowym"],"techniques_en":["Comparison with a standard wattmeter"],"techniques_zh":["与标准功率表比较"],"techniques_cs":["Porovnání s etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 od 0,5 ·Pₛₜ do 6 ·Pₛₜ CMC 0,014·Pₛₜ\nPorównanie z watomierzem wzorcowym","reference":"KP - 13","norm_bases":["KP - 13"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":"Punkty badania wg ČSN EN 61000-4-15 ed. 2, tablica 5, modulacja prostokątna, współczynnik wypełnienia 1:1","note_en":"Test points according to ČSN EN 61000-4-15 ed. 2, table 5, rectangular modulation, duty cycle 1:1","note_zh":"试验点依据 ČSN EN 61000-4-15 第2版表5，矩形调制，占空比 1:1","note_cs":"Zkušební body podle ČSN EN 61000-4-15 ed. 2, tabulka 5, obdélníková modulace, činitel plnění 1:1","search_text":"Migotanie (flicker) / mierniki Wzorcowanie – wielkości elektryczne Porównanie z watomierzem wzorcowym 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 od 0,5 ·Pₛₜ do 6 ·Pₛₜ CMC 0,014·Pₛₜ Flikr / Měřidla Kalibrace – elektrické veličiny Porovnání s etalonovým wattmetrem 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 0,5 ·Pₛₜ až 6 ·Pₛₜ CMC 0,014·Pₛₜ KP - 13 Migotanie (flicker) / mierniki Wzorcowanie – wielkosci elektryczne Porownanie z watomierzem wzorcowym 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 od 0,5 ·Pₛₜ do 6 ·Pₛₜ CMC 0,014·Pₛₜ Flikr / Meridla Kalibrace – elektricke veliciny Porovnani s etalonovym wattmetrem 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 0,5 ·Pₛₜ az 6 ·Pₛₜ CMC 0,014·Pₛₜ KP - 13","search_en":"Flicker / Meters Calibration – electrical quantities Comparison with a standard wattmeter 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 0,5 ·Pₛₜ to 6 ·Pₛₜ CMC 0,014·Pₛₜ KP - 13","search_zh":"闪变 / 测量仪器 校准 – 电学量 与标准功率表比较 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 0,5 ·Pₛₜ 至 6 ·Pₛₜ CMC 0,014·Pₛₜ KP - 13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e98452525a6526d7d6606e44","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"9","test_object":"Migotanie (flicker) / źródła","test_object_en":"Flicker / Sources","test_object_zh":"闪变 / 源","test_object_cs":"Flikr / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000","range":"od 0,5 ·Pₛₜ do 6 ·Pₛₜ","cmc":"0,014·Pₛₜ"}],"parameters_en":[{"name":"230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000","range":"0,5 ·Pₛₜ to 6 ·Pₛₜ","cmc":"0,014·Pₛₜ"}],"parameters_zh":[{"name":"230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000","range":"0,5 ·Pₛₜ 至 6 ·Pₛₜ","cmc":"0,014·Pₛₜ"}],"parameters_cs":[{"name":"230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000","range":"0,5 ·Pₛₜ až 6 ·Pₛₜ","cmc":"0,014·Pₛₜ"}],"technique":"Pomiar bezpośredni watomierzem wzorcowym","technique_en":"Direct measurement with a standard wattmeter","technique_zh":"用标准功率表直接测量","technique_cs":"Přímé měření etalonovým wattmetrem","techniques":["Pomiar bezpośredni watomierzem wzorcowym"],"techniques_en":["Direct measurement with a standard wattmeter"],"techniques_zh":["用标准功率表直接测量"],"techniques_cs":["Přímé měření etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 od 0,5 ·Pₛₜ do 6 ·Pₛₜ CMC 0,014·Pₛₜ\nPomiar bezpośredni watomierzem wzorcowym","reference":"KP - 13","norm_bases":["KP - 13"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":"Punkty badania wg ČSN EN 61000-4-15 ed. 2, tablica 5, modulacja prostokątna, współczynnik wypełnienia 1:1","note_en":"Test points according to ČSN EN 61000-4-15 ed. 2, table 5, rectangular modulation, duty cycle 1:1","note_zh":"试验点依据 ČSN EN 61000-4-15 第2版表5，矩形调制，占空比 1:1","note_cs":"Zkušební body podle ČSN EN 61000-4-15 ed. 2, tabulka 5, obdélníková modulace, činitel plnění 1:1","search_text":"Migotanie (flicker) / źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni watomierzem wzorcowym 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 od 0,5 ·Pₛₜ do 6 ·Pₛₜ CMC 0,014·Pₛₜ Flikr / Zdroje Kalibrace – elektrické veličiny Přímé měření etalonovým wattmetrem 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 0,5 ·Pₛₜ až 6 ·Pₛₜ CMC 0,014·Pₛₜ KP - 13 Migotanie (flicker) / zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni watomierzem wzorcowym 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 od 0,5 ·Pₛₜ do 6 ·Pₛₜ CMC 0,014·Pₛₜ Flikr / Zdroje Kalibrace – elektricke veliciny Prime mereni etalonovym wattmetrem 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 0,5 ·Pₛₜ az 6 ·Pₛₜ CMC 0,014·Pₛₜ KP - 13","search_en":"Flicker / Sources Calibration – electrical quantities Direct measurement with a standard wattmeter 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 0,5 ·Pₛₜ to 6 ·Pₛₜ CMC 0,014·Pₛₜ KP - 13","search_zh":"闪变 / 源 校准 – 电学量 用标准功率表直接测量 230 V, 50 Hz, CPM = 1, 2, 7, 39, 110, 1620, 4000 0,5 ·Pₛₜ 至 6 ·Pₛₜ CMC 0,014·Pₛₜ KP - 13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3cec6e16d338c10e21216f03","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"10","test_object":"Mierniki do badań instalacji elektrycznych / impedancja pętli zwarcia, impedancja sieci","test_object_en":"Inspection instruments / Protective loop impedance, mains impedance","test_object_zh":"电气安装检测仪 / 保护回路阻抗、电网阻抗","test_object_cs":"Revizní přístroje / Impedance ochranné smyčky, impedance sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 25 mΩ do 100 mΩ","cmc":"5 mΩ"},{"name":"50 Hz","range":"od 100 mΩ do 500 mΩ","cmc":"8 mΩ"},{"name":"50 Hz","range":"od 500 mΩ do 1 Ω","cmc":"10 mΩ"},{"name":"50 Hz","range":"od 1 Ω do 10 Ω","cmc":"0,5 %"},{"name":"50 Hz","range":"od 10 Ω do 2000 Ω","cmc":"0,3 %"}],"parameters_en":[{"name":"50 Hz","range":"25 mΩ to 100 mΩ","cmc":"5 mΩ"},{"name":"50 Hz","range":"100 mΩ to 500 mΩ","cmc":"8 mΩ"},{"name":"50 Hz","range":"500 mΩ to 1 Ω","cmc":"10 mΩ"},{"name":"50 Hz","range":"1 Ω to 10 Ω","cmc":"0,5 %"},{"name":"50 Hz","range":"10 Ω to 2000 Ω","cmc":"0,3 %"}],"parameters_zh":[{"name":"50 Hz","range":"25 mΩ 至 100 mΩ","cmc":"5 mΩ"},{"name":"50 Hz","range":"100 mΩ 至 500 mΩ","cmc":"8 mΩ"},{"name":"50 Hz","range":"500 mΩ 至 1 Ω","cmc":"10 mΩ"},{"name":"50 Hz","range":"1 Ω 至 10 Ω","cmc":"0,5 %"},{"name":"50 Hz","range":"10 Ω 至 2000 Ω","cmc":"0,3 %"}],"parameters_cs":[{"name":"50 Hz","range":"25 mΩ až 100 mΩ","cmc":"5 mΩ"},{"name":"50 Hz","range":"100 mΩ až 500 mΩ","cmc":"8 mΩ"},{"name":"50 Hz","range":"500 mΩ až 1 Ω","cmc":"10 mΩ"},{"name":"50 Hz","range":"1 Ω až 10 Ω","cmc":"0,5 %"},{"name":"50 Hz","range":"10 Ω až 2000 Ω","cmc":"0,3 %"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","technique_en":"Direct measurement on a calibrator of inspection instruments","technique_zh":"在电气安装检测仪校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych"],"techniques_en":["Direct measurement on a calibrator of inspection instruments"],"techniques_zh":["在电气安装检测仪校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz od 25 mΩ do 100 mΩ CMC 5 mΩ\n50 Hz od 100 mΩ do 500 mΩ CMC 8 mΩ\n50 Hz od 500 mΩ do 1 Ω CMC 10 mΩ\n50 Hz od 1 Ω do 10 Ω CMC 0,5 %\n50 Hz od 10 Ω do 2000 Ω CMC 0,3 %\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","reference":"KP - 16","norm_bases":["KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / impedancja pętli zwarcia, impedancja sieci Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych 50 Hz od 25 mΩ do 100 mΩ CMC 5 mΩ 50 Hz od 100 mΩ do 500 mΩ CMC 8 mΩ 50 Hz od 500 mΩ do 1 Ω CMC 10 mΩ 50 Hz od 1 Ω do 10 Ω CMC 0,5 % 50 Hz od 10 Ω do 2000 Ω CMC 0,3 % Revizní přístroje / Impedance ochranné smyčky, impedance sítě Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů 50 Hz 25 mΩ až 100 mΩ CMC 5 mΩ 50 Hz 100 mΩ až 500 mΩ CMC 8 mΩ 50 Hz 500 mΩ až 1 Ω CMC 10 mΩ 50 Hz 1 Ω až 10 Ω CMC 0,5 % 50 Hz 10 Ω až 2000 Ω CMC 0,3 % KP - 16 Mierniki do badan instalacji elektrycznych / impedancja petli zwarcia, impedancja sieci Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych 50 Hz od 25 mΩ do 100 mΩ CMC 5 mΩ 50 Hz od 100 mΩ do 500 mΩ CMC 8 mΩ 50 Hz od 500 mΩ do 1 Ω CMC 10 mΩ 50 Hz od 1 Ω do 10 Ω CMC 0,5 % 50 Hz od 10 Ω do 2000 Ω CMC 0,3 % Revizni pristroje / Impedance ochranne smycky, impedance site Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju 50 Hz 25 mΩ az 100 mΩ CMC 5 mΩ 50 Hz 100 mΩ az 500 mΩ CMC 8 mΩ 50 Hz 500 mΩ az 1 Ω CMC 10 mΩ 50 Hz 1 Ω az 10 Ω CMC 0,5 % 50 Hz 10 Ω az 2000 Ω CMC 0,3 % KP - 16","search_en":"Inspection instruments / Protective loop impedance, mains impedance Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments 50 Hz 25 mΩ to 100 mΩ CMC 5 mΩ 50 Hz 100 mΩ to 500 mΩ CMC 8 mΩ 50 Hz 500 mΩ to 1 Ω CMC 10 mΩ 50 Hz 1 Ω to 10 Ω CMC 0,5 % 50 Hz 10 Ω to 2000 Ω CMC 0,3 % KP - 16","search_zh":"电气安装检测仪 / 保护回路阻抗、电网阻抗 校准 – 电学量 在电气安装检测仪校准器上直接测量 50 Hz 25 mΩ 至 100 mΩ CMC 5 mΩ 50 Hz 100 mΩ 至 500 mΩ CMC 8 mΩ 50 Hz 500 mΩ 至 1 Ω CMC 10 mΩ 50 Hz 1 Ω 至 10 Ω CMC 0,5 % 50 Hz 10 Ω 至 2000 Ω CMC 0,3 % KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"216297bef52b838a15895ab5","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"10","test_object":"Mierniki do badań instalacji elektrycznych / pobór mocy","test_object_en":"Inspection instruments / Power consumption","test_object_zh":"电气安装检测仪 / 输入功率","test_object_cs":"Revizní přístroje / Příkon","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 120 VA do 2000 VA","cmc":"1 %"}],"parameters_en":[{"name":"50 Hz","range":"120 VA to 2000 VA","cmc":"1 %"}],"parameters_zh":[{"name":"50 Hz","range":"120 VA 至 2000 VA","cmc":"1 %"}],"parameters_cs":[{"name":"50 Hz","range":"120 VA až 2000 VA","cmc":"1 %"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","technique_en":"Direct measurement on a calibrator of inspection instruments","technique_zh":"在电气安装检测仪校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych"],"techniques_en":["Direct measurement on a calibrator of inspection instruments"],"techniques_zh":["在电气安装检测仪校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 120 VA do 2000 VA CMC 1 %\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","reference":"KP - 16","norm_bases":["KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / pobór mocy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych 50 Hz od 120 VA do 2000 VA CMC 1 % Revizní přístroje / Příkon Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů 50 Hz 120 VA až 2000 VA CMC 1 % KP - 16 Mierniki do badan instalacji elektrycznych / pobor mocy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych 50 Hz od 120 VA do 2000 VA CMC 1 % Revizni pristroje / Prikon Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju 50 Hz 120 VA az 2000 VA CMC 1 % KP - 16","search_en":"Inspection instruments / Power consumption Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments 50 Hz 120 VA to 2000 VA CMC 1 % KP - 16","search_zh":"电气安装检测仪 / 输入功率 校准 – 电学量 在电气安装检测仪校准器上直接测量 50 Hz 120 VA 至 2000 VA CMC 1 % KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d7f8c822804c7f14bfc0365","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"10","test_object":"Mierniki do badań instalacji elektrycznych / prąd wyzwalania wyłączników różnicowoprądowych","test_object_en":"Inspection instruments / Tripping current of residual current devices","test_object_zh":"电气安装检测仪 / 剩余电流保护器动作电流","test_object_cs":"Revizní přístroje / Vypínací proud chráničů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 3 mA do 3 A","cmc":"1,2 %"}],"parameters_en":[{"name":"50 Hz","range":"3 mA to 3 A","cmc":"1,2 %"}],"parameters_zh":[{"name":"50 Hz","range":"3 mA 至 3 A","cmc":"1,2 %"}],"parameters_cs":[{"name":"50 Hz","range":"3 mA až 3 A","cmc":"1,2 %"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","technique_en":"Direct measurement on a calibrator of inspection instruments","technique_zh":"在电气安装检测仪校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych"],"techniques_en":["Direct measurement on a calibrator of inspection instruments"],"techniques_zh":["在电气安装检测仪校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 3 mA do 3 A CMC 1,2 %\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","reference":"KP - 16","norm_bases":["KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / prąd wyzwalania wyłączników różnicowoprądowych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych 50 Hz od 3 mA do 3 A CMC 1,2 % Revizní přístroje / Vypínací proud chráničů Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů 50 Hz 3 mA až 3 A CMC 1,2 % KP - 16 Mierniki do badan instalacji elektrycznych / prad wyzwalania wylacznikow roznicowopradowych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych 50 Hz od 3 mA do 3 A CMC 1,2 % Revizni pristroje / Vypinaci proud chranicu Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju 50 Hz 3 mA az 3 A CMC 1,2 % KP - 16","search_en":"Inspection instruments / Tripping current of residual current devices Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments 50 Hz 3 mA to 3 A CMC 1,2 % KP - 16","search_zh":"电气安装检测仪 / 剩余电流保护器动作电流 校准 – 电学量 在电气安装检测仪校准器上直接测量 50 Hz 3 mA 至 3 A CMC 1,2 % KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1a4d593259e7b8e3ab5c7607","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"10","test_object":"Mierniki do badań instalacji elektrycznych / czas wyzwalania wyłączników różnicowoprądowych","test_object_en":"Inspection instruments / Tripping time of residual current devices","test_object_zh":"电气安装检测仪 / 剩余电流保护器动作时间","test_object_cs":"Revizní přístroje / Vypínací čas chráničů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 20 ms do 1 s","cmc":"0,02 % + 0,25 ms"}],"parameters_en":[{"name":"50 Hz","range":"20 ms to 1 s","cmc":"0,02 % + 0,25 ms"}],"parameters_zh":[{"name":"50 Hz","range":"20 ms 至 1 s","cmc":"0,02 % + 0,25 ms"}],"parameters_cs":[{"name":"50 Hz","range":"20 ms až 1 s","cmc":"0,02 % + 0,25 ms"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","technique_en":"Direct measurement on a calibrator of inspection instruments","technique_zh":"在电气安装检测仪校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych"],"techniques_en":["Direct measurement on a calibrator of inspection instruments"],"techniques_zh":["在电气安装检测仪校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 20 ms do 1 s CMC 0,02 % + 0,25 ms\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","reference":"KP - 16","norm_bases":["KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / czas wyzwalania wyłączników różnicowoprądowych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych 50 Hz od 20 ms do 1 s CMC 0,02 % + 0,25 ms Revizní přístroje / Vypínací čas chráničů Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů 50 Hz 20 ms až 1 s CMC 0,02 % + 0,25 ms KP - 16 Mierniki do badan instalacji elektrycznych / czas wyzwalania wylacznikow roznicowopradowych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych 50 Hz od 20 ms do 1 s CMC 0,02 % + 0,25 ms Revizni pristroje / Vypinaci cas chranicu Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju 50 Hz 20 ms az 1 s CMC 0,02 % + 0,25 ms KP - 16","search_en":"Inspection instruments / Tripping time of residual current devices Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments 50 Hz 20 ms to 1 s CMC 0,02 % + 0,25 ms KP - 16","search_zh":"电气安装检测仪 / 剩余电流保护器动作时间 校准 – 电学量 在电气安装检测仪校准器上直接测量 50 Hz 20 ms 至 1 s CMC 0,02 % + 0,25 ms KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ed6b996988c00cfdebdd5568","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"10","test_object":"Mierniki do badań instalacji elektrycznych / prąd upływu pasywny, różnicowy, zastępczy, dotykowy","test_object_en":"Inspection instruments / Leakage current – passive, differential, substitute, touch","test_object_zh":"电气安装检测仪 / 泄漏电流（无源、差动、替代、接触）","test_object_cs":"Revizní přístroje / Unikající proud pasivní, rozdílový, substituční, dotykový","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 0,1 mA do 30 mA","cmc":"0,3 % + 2 µA"}],"parameters_en":[{"name":"50 Hz","range":"0,1 mA to 30 mA","cmc":"0,3 % + 2 µA"}],"parameters_zh":[{"name":"50 Hz","range":"0,1 mA 至 30 mA","cmc":"0,3 % + 2 µA"}],"parameters_cs":[{"name":"50 Hz","range":"0,1 mA až 30 mA","cmc":"0,3 % + 2 µA"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","technique_en":"Direct measurement on a calibrator of inspection instruments","technique_zh":"在电气安装检测仪校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych"],"techniques_en":["Direct measurement on a calibrator of inspection instruments"],"techniques_zh":["在电气安装检测仪校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 0,1 mA do 30 mA CMC 0,3 % + 2 µA\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","reference":"KP - 16","norm_bases":["KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / prąd upływu pasywny, różnicowy, zastępczy, dotykowy Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych 50 Hz od 0,1 mA do 30 mA CMC 0,3 % + 2 µA Revizní přístroje / Unikající proud pasivní, rozdílový, substituční, dotykový Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů 50 Hz 0,1 mA až 30 mA CMC 0,3 % + 2 µA KP - 16 Mierniki do badan instalacji elektrycznych / prad uplywu pasywny, roznicowy, zastepczy, dotykowy Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych 50 Hz od 0,1 mA do 30 mA CMC 0,3 % + 2 µA Revizni pristroje / Unikajici proud pasivni, rozdilovy, substitucni, dotykovy Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju 50 Hz 0,1 mA az 30 mA CMC 0,3 % + 2 µA KP - 16","search_en":"Inspection instruments / Leakage current – passive, differential, substitute, touch Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments 50 Hz 0,1 mA to 30 mA CMC 0,3 % + 2 µA KP - 16","search_zh":"电气安装检测仪 / 泄漏电流（无源、差动、替代、接触） 校准 – 电学量 在电气安装检测仪校准器上直接测量 50 Hz 0,1 mA 至 30 mA CMC 0,3 % + 2 µA KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"18d0d48a0d0d4112407ca5bc","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"10","test_object":"Mierniki do badań instalacji elektrycznych / prądy upływu – źródła","test_object_en":"Inspection instruments / Leakage currents – sources","test_object_zh":"电气安装检测仪 / 泄漏电流 – 电流源","test_object_cs":"Revizní přístroje / Unikající proudy - zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"DC, 10 Hz do 400 Hz","range":"od 0,1 mA do 300 mA","cmc":"0,3 %"}],"parameters_en":[{"name":"DC, 10 Hz to 400 Hz","range":"0,1 mA to 300 mA","cmc":"0,3 %"}],"parameters_zh":[{"name":"DC，10 Hz 至 400 Hz","range":"0,1 mA 至 300 mA","cmc":"0,3 %"}],"parameters_cs":[{"name":"DC, 10 Hz až 400 Hz","range":"0,1 mA až 300 mA","cmc":"0,3 %"}],"technique":"Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","technique_en":"Direct measurement on a calibrator of inspection instruments","technique_zh":"在电气安装检测仪校准器上直接测量","technique_cs":"Přímé měření na kalibrátoru revizních přístrojů","techniques":["Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych"],"techniques_en":["Direct measurement on a calibrator of inspection instruments"],"techniques_zh":["在电气安装检测仪校准器上直接测量"],"techniques_cs":["Přímé měření na kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nDC, 10 Hz do 400 Hz od 0,1 mA do 300 mA CMC 0,3 %\nPomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych","reference":"KP - 16","norm_bases":["KP - 16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki do badań instalacji elektrycznych / prądy upływu – źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze mierników do badań instalacji elektrycznych DC, 10 Hz do 400 Hz od 0,1 mA do 300 mA CMC 0,3 % Revizní přístroje / Unikající proudy - zdroje Kalibrace – elektrické veličiny Přímé měření na kalibrátoru revizních přístrojů DC, 10 Hz až 400 Hz 0,1 mA až 300 mA CMC 0,3 % KP - 16 Mierniki do badan instalacji elektrycznych / prady uplywu – zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze miernikow do badan instalacji elektrycznych DC, 10 Hz do 400 Hz od 0,1 mA do 300 mA CMC 0,3 % Revizni pristroje / Unikajici proudy - zdroje Kalibrace – elektricke veliciny Prime mereni na kalibratoru reviznich pristroju DC, 10 Hz az 400 Hz 0,1 mA az 300 mA CMC 0,3 % KP - 16","search_en":"Inspection instruments / Leakage currents – sources Calibration – electrical quantities Direct measurement on a calibrator of inspection instruments DC, 10 Hz to 400 Hz 0,1 mA to 300 mA CMC 0,3 % KP - 16","search_zh":"电气安装检测仪 / 泄漏电流 – 电流源 校准 – 电学量 在电气安装检测仪校准器上直接测量 DC，10 Hz 至 400 Hz 0,1 mA 至 300 mA CMC 0,3 % KP - 16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6ca3372d386c11ed8783eb57","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"11","test_object":"Moduł impedancji / wzorce i mierniki","test_object_en":"Impedance modulus / Standards and meters","test_object_zh":"阻抗模 / 标准器和测量仪器","test_object_cs":"Modul impedance / Etalony a měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 400 Hz","range":"od 20 mΩ do 1 Ω","cmc":"0,1 %"},{"name":"400 Hz do 5 kHz","range":"od 20 mΩ do 1 Ω","cmc":"0,3 %"},{"name":"40 Hz do 400 Hz","range":"od 1 Ω do 1 kΩ","cmc":"0,02 %"},{"name":"400 Hz do 5 kHz","range":"od 1 Ω do 1 kΩ","cmc":"0,05 %"},{"name":"40 Hz do 400 Hz","range":"od 1 kΩ do 100 kΩ","cmc":"0,03 %"},{"name":"400 Hz do 1 kHz","range":"od 1 kΩ do 100 kΩ","cmc":"0,06 %"}],"parameters_en":[{"name":"40 Hz to 400 Hz","range":"20 mΩ to 1 Ω","cmc":"0,1 %"},{"name":"400 Hz to 5 kHz","range":"20 mΩ to 1 Ω","cmc":"0,3 %"},{"name":"40 Hz to 400 Hz","range":"1 Ω to 1 kΩ","cmc":"0,02 %"},{"name":"400 Hz to 5 kHz","range":"1 Ω to 1 kΩ","cmc":"0,05 %"},{"name":"40 Hz to 400 Hz","range":"1 kΩ to 100 kΩ","cmc":"0,03 %"},{"name":"400 Hz to 1 kHz","range":"1 kΩ to 100 kΩ","cmc":"0,06 %"}],"parameters_zh":[{"name":"40 Hz 至 400 Hz","range":"20 mΩ 至 1 Ω","cmc":"0,1 %"},{"name":"400 Hz 至 5 kHz","range":"20 mΩ 至 1 Ω","cmc":"0,3 %"},{"name":"40 Hz 至 400 Hz","range":"1 Ω 至 1 kΩ","cmc":"0,02 %"},{"name":"400 Hz 至 5 kHz","range":"1 Ω 至 1 kΩ","cmc":"0,05 %"},{"name":"40 Hz 至 400 Hz","range":"1 kΩ 至 100 kΩ","cmc":"0,03 %"},{"name":"400 Hz 至 1 kHz","range":"1 kΩ 至 100 kΩ","cmc":"0,06 %"}],"parameters_cs":[{"name":"40 Hz až 400 Hz","range":"20 mΩ až 1 Ω","cmc":"0,1 %"},{"name":"400 Hz až 5 kHz","range":"20 mΩ až 1 Ω","cmc":"0,3 %"},{"name":"40 Hz až 400 Hz","range":"1 Ω až 1 kΩ","cmc":"0,02 %"},{"name":"400 Hz až 5 kHz","range":"1 Ω až 1 kΩ","cmc":"0,05 %"},{"name":"40 Hz až 400 Hz","range":"1 kΩ až 100 kΩ","cmc":"0,03 %"},{"name":"400 Hz až 1 kHz","range":"1 kΩ až 100 kΩ","cmc":"0,06 %"}],"technique":"Pomiar pośredni metodą techniczną / pomiar bezpośredni wzorca","technique_en":"Indirect measurement by the voltammeter–ammeter method / direct measurement of a standard","technique_zh":"伏安法间接测量 / 直接测量标准器","technique_cs":"Nepřímé měření voltampérovou metodou / přímé měření etalonu","techniques":["Pomiar pośredni metodą techniczną / pomiar bezpośredni wzorca"],"techniques_en":["Indirect measurement by the voltammeter–ammeter method / direct measurement of a standard"],"techniques_zh":["伏安法间接测量 / 直接测量标准器"],"techniques_cs":["Nepřímé měření voltampérovou metodou / přímé měření etalonu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 400 Hz od 20 mΩ do 1 Ω CMC 0,1 %\n400 Hz do 5 kHz od 20 mΩ do 1 Ω CMC 0,3 %\n40 Hz do 400 Hz od 1 Ω do 1 kΩ CMC 0,02 %\n400 Hz do 5 kHz od 1 Ω do 1 kΩ CMC 0,05 %\n40 Hz do 400 Hz od 1 kΩ do 100 kΩ CMC 0,03 %\n400 Hz do 1 kHz od 1 kΩ do 100 kΩ CMC 0,06 %\nPomiar pośredni metodą techniczną / pomiar bezpośredni wzorca","reference":"KP - 18","norm_bases":["KP - 18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduł impedancji / wzorce i mierniki Wzorcowanie – wielkości elektryczne Pomiar pośredni metodą techniczną / pomiar bezpośredni wzorca 40 Hz do 400 Hz od 20 mΩ do 1 Ω CMC 0,1 % 400 Hz do 5 kHz od 20 mΩ do 1 Ω CMC 0,3 % 40 Hz do 400 Hz od 1 Ω do 1 kΩ CMC 0,02 % 400 Hz do 5 kHz od 1 Ω do 1 kΩ CMC 0,05 % 40 Hz do 400 Hz od 1 kΩ do 100 kΩ CMC 0,03 % 400 Hz do 1 kHz od 1 kΩ do 100 kΩ CMC 0,06 % Modul impedance / Etalony a měřidla Kalibrace – elektrické veličiny Nepřímé měření voltampérovou metodou / přímé měření etalonu 40 Hz až 400 Hz 20 mΩ až 1 Ω CMC 0,1 % 400 Hz až 5 kHz 20 mΩ až 1 Ω CMC 0,3 % 40 Hz až 400 Hz 1 Ω až 1 kΩ CMC 0,02 % 400 Hz až 5 kHz 1 Ω až 1 kΩ CMC 0,05 % 40 Hz až 400 Hz 1 kΩ až 100 kΩ CMC 0,03 % 400 Hz až 1 kHz 1 kΩ až 100 kΩ CMC 0,06 % KP - 18 Modul impedancji / wzorce i mierniki Wzorcowanie – wielkosci elektryczne Pomiar posredni metoda techniczna / pomiar bezposredni wzorca 40 Hz do 400 Hz od 20 mΩ do 1 Ω CMC 0,1 % 400 Hz do 5 kHz od 20 mΩ do 1 Ω CMC 0,3 % 40 Hz do 400 Hz od 1 Ω do 1 kΩ CMC 0,02 % 400 Hz do 5 kHz od 1 Ω do 1 kΩ CMC 0,05 % 40 Hz do 400 Hz od 1 kΩ do 100 kΩ CMC 0,03 % 400 Hz do 1 kHz od 1 kΩ do 100 kΩ CMC 0,06 % Modul impedance / Etalony a meridla Kalibrace – elektricke veliciny Neprime mereni voltamperovou metodou / prime mereni etalonu 40 Hz az 400 Hz 20 mΩ az 1 Ω CMC 0,1 % 400 Hz az 5 kHz 20 mΩ az 1 Ω CMC 0,3 % 40 Hz az 400 Hz 1 Ω az 1 kΩ CMC 0,02 % 400 Hz az 5 kHz 1 Ω az 1 kΩ CMC 0,05 % 40 Hz az 400 Hz 1 kΩ az 100 kΩ CMC 0,03 % 400 Hz az 1 kHz 1 kΩ az 100 kΩ CMC 0,06 % KP - 18","search_en":"Impedance modulus / Standards and meters Calibration – electrical quantities Indirect measurement by the voltammeter–ammeter method / direct measurement of a standard 40 Hz to 400 Hz 20 mΩ to 1 Ω CMC 0,1 % 400 Hz to 5 kHz 20 mΩ to 1 Ω CMC 0,3 % 40 Hz to 400 Hz 1 Ω to 1 kΩ CMC 0,02 % 400 Hz to 5 kHz 1 Ω to 1 kΩ CMC 0,05 % 40 Hz to 400 Hz 1 kΩ to 100 kΩ CMC 0,03 % 400 Hz to 1 kHz 1 kΩ to 100 kΩ CMC 0,06 % KP - 18","search_zh":"阻抗模 / 标准器和测量仪器 校准 – 电学量 伏安法间接测量 / 直接测量标准器 40 Hz 至 400 Hz 20 mΩ 至 1 Ω CMC 0,1 % 400 Hz 至 5 kHz 20 mΩ 至 1 Ω CMC 0,3 % 40 Hz 至 400 Hz 1 Ω 至 1 kΩ CMC 0,02 % 400 Hz 至 5 kHz 1 Ω 至 1 kΩ CMC 0,05 % 40 Hz 至 400 Hz 1 kΩ 至 100 kΩ CMC 0,03 % 400 Hz 至 1 kHz 1 kΩ 至 100 kΩ CMC 0,06 % KP - 18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"893b61ad491d479aaab028af","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"12","test_object":"Kąt fazowy U-I / mierniki","test_object_en":"Phase angle U-I / Meters","test_object_zh":"U-I 相位角 / 测量仪器","test_object_cs":"Fázový úhel U-I / Měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V, 40 Hz do 70 Hz, 0,1 A do 90 A","range":"od 0 ° do 359,9 °","cmc":"0,01 °"}],"parameters_en":[{"name":"1 V to 400 V, 40 Hz to 70 Hz, 0.1 A to 90 A","range":"0 ° to 359,9 °","cmc":"0,01 °"}],"parameters_zh":[{"name":"1 V 至 400 V，40 Hz 至 70 Hz，0,1 A 至 90 A","range":"0 ° 至 359,9 °","cmc":"0,01 °"}],"parameters_cs":[{"name":"1 V až 400 V, 40 Hz až 70 Hz, 0,1 A až 90 A","range":"0 ° až 359,9 °","cmc":"0,01 °"}],"technique":"Porównanie z watomierzem wzorcowym","technique_en":"Comparison with a standard wattmeter","technique_zh":"与标准功率表比较","technique_cs":"Porovnání s etalonovým wattmetrem","techniques":["Porównanie z watomierzem wzorcowym"],"techniques_en":["Comparison with a standard wattmeter"],"techniques_zh":["与标准功率表比较"],"techniques_cs":["Porovnání s etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V, 40 Hz do 70 Hz, 0,1 A do 90 A od 0 ° do 359,9 ° CMC 0,01 °\nPorównanie z watomierzem wzorcowym","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt fazowy U-I / mierniki Wzorcowanie – wielkości elektryczne Porównanie z watomierzem wzorcowym 1 V do 400 V, 40 Hz do 70 Hz, 0,1 A do 90 A od 0 ° do 359,9 ° CMC 0,01 ° Fázový úhel U-I / Měřidla Kalibrace – elektrické veličiny Porovnání s etalonovým wattmetrem 1 V až 400 V, 40 Hz až 70 Hz, 0,1 A až 90 A 0 ° až 359,9 ° CMC 0,01 ° KP - 11 Kat fazowy U-I / mierniki Wzorcowanie – wielkosci elektryczne Porownanie z watomierzem wzorcowym 1 V do 400 V, 40 Hz do 70 Hz, 0,1 A do 90 A od 0 ° do 359,9 ° CMC 0,01 ° Fazovy uhel U-I / Meridla Kalibrace – elektricke veliciny Porovnani s etalonovym wattmetrem 1 V az 400 V, 40 Hz az 70 Hz, 0,1 A az 90 A 0 ° az 359,9 ° CMC 0,01 ° KP - 11","search_en":"Phase angle U-I / Meters Calibration – electrical quantities Comparison with a standard wattmeter 1 V to 400 V, 40 Hz to 70 Hz, 0.1 A to 90 A 0 ° to 359,9 ° CMC 0,01 ° KP - 11","search_zh":"U-I 相位角 / 测量仪器 校准 – 电学量 与标准功率表比较 1 V 至 400 V，40 Hz 至 70 Hz，0,1 A 至 90 A 0 ° 至 359,9 ° CMC 0,01 ° KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2bb97b248a9040e701e35049","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"12","test_object":"Współczynnik mocy / mierniki","test_object_en":"Power factor / Meters","test_object_zh":"功率因数 / 测量仪器","test_object_cs":"Účiník / Měřidla","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,1 do 1","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"0,1 to 1","cmc":"0,2 %"}],"parameters_zh":[{"name":"","range":"0,1 至 1","cmc":"0,2 %"}],"parameters_cs":[{"name":"","range":"0,1 až 1","cmc":"0,2 %"}],"technique":"Porównanie z watomierzem wzorcowym","technique_en":"Comparison with a standard wattmeter","technique_zh":"与标准功率表比较","technique_cs":"Porovnání s etalonovým wattmetrem","techniques":["Porównanie z watomierzem wzorcowym"],"techniques_en":["Comparison with a standard wattmeter"],"techniques_zh":["与标准功率表比较"],"techniques_cs":["Porovnání s etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 0,1 do 1 CMC 0,2 %\nPorównanie z watomierzem wzorcowym","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik mocy / mierniki Wzorcowanie – wielkości elektryczne Porównanie z watomierzem wzorcowym od 0,1 do 1 CMC 0,2 % Účiník / Měřidla Kalibrace – elektrické veličiny Porovnání s etalonovým wattmetrem 0,1 až 1 CMC 0,2 % KP - 11 Wspolczynnik mocy / mierniki Wzorcowanie – wielkosci elektryczne Porownanie z watomierzem wzorcowym od 0,1 do 1 CMC 0,2 % Ucinik / Meridla Kalibrace – elektricke veliciny Porovnani s etalonovym wattmetrem 0,1 az 1 CMC 0,2 % KP - 11","search_en":"Power factor / Meters Calibration – electrical quantities Comparison with a standard wattmeter 0,1 to 1 CMC 0,2 % KP - 11","search_zh":"功率因数 / 测量仪器 校准 – 电学量 与标准功率表比较 0,1 至 1 CMC 0,2 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1de33ab89851bc9faa7a725","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"12","test_object":"Kąt fazowy U-I / źródła","test_object_en":"Phase angle U-I / Sources","test_object_zh":"U-I 相位角 / 源","test_object_cs":"Fázový úhel U-I / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 400 V, 40 Hz do 70 Hz, 0,03 A do 100 A","range":"od 0 ° do 359,9 °","cmc":"0,01 °"}],"parameters_en":[{"name":"1 V to 400 V, 40 Hz to 70 Hz, 0.03 A to 100 A","range":"0 ° to 359,9 °","cmc":"0,01 °"}],"parameters_zh":[{"name":"1 V 至 400 V，40 Hz 至 70 Hz，0,03 A 至 100 A","range":"0 ° 至 359,9 °","cmc":"0,01 °"}],"parameters_cs":[{"name":"1 V až 400 V, 40 Hz až 70 Hz, 0,03 A až 100 A","range":"0 ° až 359,9 °","cmc":"0,01 °"}],"technique":"Pomiar bezpośredni watomierzem wzorcowym","technique_en":"Direct measurement with a standard wattmeter","technique_zh":"用标准功率表直接测量","technique_cs":"Přímé měření etalonovým wattmetrem","techniques":["Pomiar bezpośredni watomierzem wzorcowym"],"techniques_en":["Direct measurement with a standard wattmeter"],"techniques_zh":["用标准功率表直接测量"],"techniques_cs":["Přímé měření etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 400 V, 40 Hz do 70 Hz, 0,03 A do 100 A od 0 ° do 359,9 ° CMC 0,01 °\nPomiar bezpośredni watomierzem wzorcowym","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt fazowy U-I / źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni watomierzem wzorcowym 1 V do 400 V, 40 Hz do 70 Hz, 0,03 A do 100 A od 0 ° do 359,9 ° CMC 0,01 ° Fázový úhel U-I / Zdroje Kalibrace – elektrické veličiny Přímé měření etalonovým wattmetrem 1 V až 400 V, 40 Hz až 70 Hz, 0,03 A až 100 A 0 ° až 359,9 ° CMC 0,01 ° KP - 11 Kat fazowy U-I / zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni watomierzem wzorcowym 1 V do 400 V, 40 Hz do 70 Hz, 0,03 A do 100 A od 0 ° do 359,9 ° CMC 0,01 ° Fazovy uhel U-I / Zdroje Kalibrace – elektricke veliciny Prime mereni etalonovym wattmetrem 1 V az 400 V, 40 Hz az 70 Hz, 0,03 A az 100 A 0 ° az 359,9 ° CMC 0,01 ° KP - 11","search_en":"Phase angle U-I / Sources Calibration – electrical quantities Direct measurement with a standard wattmeter 1 V to 400 V, 40 Hz to 70 Hz, 0.03 A to 100 A 0 ° to 359,9 ° CMC 0,01 ° KP - 11","search_zh":"U-I 相位角 / 源 校准 – 电学量 用标准功率表直接测量 1 V 至 400 V，40 Hz 至 70 Hz，0,03 A 至 100 A 0 ° 至 359,9 ° CMC 0,01 ° KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"60bee1862728124fa7a1000c","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"12","test_object":"Współczynnik mocy / źródła","test_object_en":"Power factor / Sources","test_object_zh":"功率因数 / 源","test_object_cs":"Účiník / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,1 do 1","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"0,1 to 1","cmc":"0,2 %"}],"parameters_zh":[{"name":"","range":"0,1 至 1","cmc":"0,2 %"}],"parameters_cs":[{"name":"","range":"0,1 až 1","cmc":"0,2 %"}],"technique":"Pomiar bezpośredni watomierzem wzorcowym","technique_en":"Direct measurement with a standard wattmeter","technique_zh":"用标准功率表直接测量","technique_cs":"Přímé měření etalonovým wattmetrem","techniques":["Pomiar bezpośredni watomierzem wzorcowym"],"techniques_en":["Direct measurement with a standard wattmeter"],"techniques_zh":["用标准功率表直接测量"],"techniques_cs":["Přímé měření etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 0,1 do 1 CMC 0,2 %\nPomiar bezpośredni watomierzem wzorcowym","reference":"KP - 11","norm_bases":["KP - 11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik mocy / źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni watomierzem wzorcowym od 0,1 do 1 CMC 0,2 % Účiník / Zdroje Kalibrace – elektrické veličiny Přímé měření etalonovým wattmetrem 0,1 až 1 CMC 0,2 % KP - 11 Wspolczynnik mocy / zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni watomierzem wzorcowym od 0,1 do 1 CMC 0,2 % Ucinik / Zdroje Kalibrace – elektricke veliciny Prime mereni etalonovym wattmetrem 0,1 az 1 CMC 0,2 % KP - 11","search_en":"Power factor / Sources Calibration – electrical quantities Direct measurement with a standard wattmeter 0,1 to 1 CMC 0,2 % KP - 11","search_zh":"功率因数 / 源 校准 – 电学量 用标准功率表直接测量 0,1 至 1 CMC 0,2 % KP - 11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"956eed16eec76110e6361d7b","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / mierniki częstotliwości napięcia przemiennego","test_object_en":"Frequency / AC voltage frequency meters","test_object_zh":"频率 / 交流电压频率测量仪器","test_object_cs":"Frekvence / Měřidla frekvence střídavého napětí","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"0,1 V do 10 V","range":"od 0,5 Hz do 10 Hz","cmc":"0,001 %"},{"name":"0,1 V do 10 V","range":"od 10 Hz do 10 MHz","cmc":"0,001 %"},{"name":"10 V do 750 V","range":"od 10 Hz do 10 MHz","cmc":"0,01 %"},{"name":"0,1 V do 10 V","range":"od 10 MHz do 20 MHz","cmc":"0,001 %"}],"parameters_en":[{"name":"0,1 V to 10 V","range":"0,5 Hz to 10 Hz","cmc":"0,001 %"},{"name":"0,1 V to 10 V","range":"10 Hz to 10 MHz","cmc":"0,001 %"},{"name":"10 V to 750 V","range":"10 Hz to 10 MHz","cmc":"0,01 %"},{"name":"0,1 V to 10 V","range":"10 MHz to 20 MHz","cmc":"0,001 %"}],"parameters_zh":[{"name":"0,1 V 至 10 V","range":"0,5 Hz 至 10 Hz","cmc":"0,001 %"},{"name":"0,1 V 至 10 V","range":"10 Hz 至 10 MHz","cmc":"0,001 %"},{"name":"10 V 至 750 V","range":"10 Hz 至 10 MHz","cmc":"0,01 %"},{"name":"0,1 V 至 10 V","range":"10 MHz 至 20 MHz","cmc":"0,001 %"}],"parameters_cs":[{"name":"0,1 V až 10 V","range":"0,5 Hz až 10 Hz","cmc":"0,001 %"},{"name":"0,1 V až 10 V","range":"10 Hz až 10 MHz","cmc":"0,001 %"},{"name":"10 V až 750 V","range":"10 Hz až 10 MHz","cmc":"0,01 %"},{"name":"0,1 V až 10 V","range":"10 MHz až 20 MHz","cmc":"0,001 %"}],"technique":"Porównanie z licznikiem wzorcowym","technique_en":"Comparison with a standard counter","technique_zh":"与标准计数器比较","technique_cs":"Porovnání s etalonovým čítačem","techniques":["Porównanie z licznikiem wzorcowym"],"techniques_en":["Comparison with a standard counter"],"techniques_zh":["与标准计数器比较"],"techniques_cs":["Porovnání s etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\n0,1 V do 10 V od 0,5 Hz do 10 Hz CMC 0,001 %\n0,1 V do 10 V od 10 Hz do 10 MHz CMC 0,001 %\n10 V do 750 V od 10 Hz do 10 MHz CMC 0,01 %\n0,1 V do 10 V od 10 MHz do 20 MHz CMC 0,001 %\nPorównanie z licznikiem wzorcowym","reference":"KP - 12","norm_bases":["KP - 12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / mierniki częstotliwości napięcia przemiennego Wzorcowanie – wielkości czasu i częstotliwości Porównanie z licznikiem wzorcowym 0,1 V do 10 V od 0,5 Hz do 10 Hz CMC 0,001 % 0,1 V do 10 V od 10 Hz do 10 MHz CMC 0,001 % 10 V do 750 V od 10 Hz do 10 MHz CMC 0,01 % 0,1 V do 10 V od 10 MHz do 20 MHz CMC 0,001 % Frekvence / Měřidla frekvence střídavého napětí Kalibrace – veličiny času a frekvence Porovnání s etalonovým čítačem 0,1 V až 10 V 0,5 Hz až 10 Hz CMC 0,001 % 0,1 V až 10 V 10 Hz až 10 MHz CMC 0,001 % 10 V až 750 V 10 Hz až 10 MHz CMC 0,01 % 0,1 V až 10 V 10 MHz až 20 MHz CMC 0,001 % KP - 12 Czestotliwosc / mierniki czestotliwosci napiecia przemiennego Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie z licznikiem wzorcowym 0,1 V do 10 V od 0,5 Hz do 10 Hz CMC 0,001 % 0,1 V do 10 V od 10 Hz do 10 MHz CMC 0,001 % 10 V do 750 V od 10 Hz do 10 MHz CMC 0,01 % 0,1 V do 10 V od 10 MHz do 20 MHz CMC 0,001 % Frekvence / Meridla frekvence stridaveho napeti Kalibrace – veliciny casu a frekvence Porovnani s etalonovym citacem 0,1 V az 10 V 0,5 Hz az 10 Hz CMC 0,001 % 0,1 V az 10 V 10 Hz az 10 MHz CMC 0,001 % 10 V az 750 V 10 Hz az 10 MHz CMC 0,01 % 0,1 V az 10 V 10 MHz az 20 MHz CMC 0,001 % KP - 12","search_en":"Frequency / AC voltage frequency meters Calibration – time and frequency quantities Comparison with a standard counter 0,1 V to 10 V 0,5 Hz to 10 Hz CMC 0,001 % 0,1 V to 10 V 10 Hz to 10 MHz CMC 0,001 % 10 V to 750 V 10 Hz to 10 MHz CMC 0,01 % 0,1 V to 10 V 10 MHz to 20 MHz CMC 0,001 % KP - 12","search_zh":"频率 / 交流电压频率测量仪器 校准 – 时间和频率量 与标准计数器比较 0,1 V 至 10 V 0,5 Hz 至 10 Hz CMC 0,001 % 0,1 V 至 10 V 10 Hz 至 10 MHz CMC 0,001 % 10 V 至 750 V 10 Hz 至 10 MHz CMC 0,01 % 0,1 V 至 10 V 10 MHz 至 20 MHz CMC 0,001 % KP - 12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"270507b6911afc48a6620111","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / mierniki częstotliwości prądu przemiennego","test_object_en":"Frequency / AC current frequency meters","test_object_zh":"频率 / 交流电流频率测量仪器","test_object_cs":"Frekvence / Měřidla frekvence střídavého proudu","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"0,05 A do 90 A","range":"od 20 Hz do 1 kHz","cmc":"0,01 %"}],"parameters_en":[{"name":"0,05 A to 90 A","range":"20 Hz to 1 kHz","cmc":"0,01 %"}],"parameters_zh":[{"name":"0,05 A 至 90 A","range":"20 Hz 至 1 kHz","cmc":"0,01 %"}],"parameters_cs":[{"name":"0,05 A až 90 A","range":"20 Hz až 1 kHz","cmc":"0,01 %"}],"technique":"Porównanie z watomierzem wzorcowym","technique_en":"Comparison with a standard wattmeter","technique_zh":"与标准功率表比较","technique_cs":"Porovnání s etalonovým wattmetrem","techniques":["Porównanie z watomierzem wzorcowym"],"techniques_en":["Comparison with a standard wattmeter"],"techniques_zh":["与标准功率表比较"],"techniques_cs":["Porovnání s etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\n0,05 A do 90 A od 20 Hz do 1 kHz CMC 0,01 %\nPorównanie z watomierzem wzorcowym","reference":"KP - 12","norm_bases":["KP - 12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / mierniki częstotliwości prądu przemiennego Wzorcowanie – wielkości czasu i częstotliwości Porównanie z watomierzem wzorcowym 0,05 A do 90 A od 20 Hz do 1 kHz CMC 0,01 % Frekvence / Měřidla frekvence střídavého proudu Kalibrace – veličiny času a frekvence Porovnání s etalonovým wattmetrem 0,05 A až 90 A 20 Hz až 1 kHz CMC 0,01 % KP - 12 Czestotliwosc / mierniki czestotliwosci pradu przemiennego Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie z watomierzem wzorcowym 0,05 A do 90 A od 20 Hz do 1 kHz CMC 0,01 % Frekvence / Meridla frekvence stridaveho proudu Kalibrace – veliciny casu a frekvence Porovnani s etalonovym wattmetrem 0,05 A az 90 A 20 Hz az 1 kHz CMC 0,01 % KP - 12","search_en":"Frequency / AC current frequency meters Calibration – time and frequency quantities Comparison with a standard wattmeter 0,05 A to 90 A 20 Hz to 1 kHz CMC 0,01 % KP - 12","search_zh":"频率 / 交流电流频率测量仪器 校准 – 时间和频率量 与标准功率表比较 0,05 A 至 90 A 20 Hz 至 1 kHz CMC 0,01 % KP - 12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c8ea0e2937b83845fa649836","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / źródła napięcia przemiennego","test_object_en":"Frequency / AC voltage sources","test_object_zh":"频率 / 交流电压源","test_object_cs":"Frekvence / Zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"0,1 V do 10 V","range":"od 0,5 Hz do 10 Hz","cmc":"0,001 %"},{"name":"0,1 V do 10 V","range":"od 10 Hz do 10 MHz","cmc":"0,001 %"},{"name":"10 V do 750 V","range":"od 10 Hz do 10 MHz","cmc":"0,01 %"},{"name":"0,1 V do 10 V","range":"od 10 MHz do 20 MHz","cmc":"0,001 %"}],"parameters_en":[{"name":"0,1 V to 10 V","range":"0,5 Hz to 10 Hz","cmc":"0,001 %"},{"name":"0,1 V to 10 V","range":"10 Hz to 10 MHz","cmc":"0,001 %"},{"name":"10 V to 750 V","range":"10 Hz to 10 MHz","cmc":"0,01 %"},{"name":"0,1 V to 10 V","range":"10 MHz to 20 MHz","cmc":"0,001 %"}],"parameters_zh":[{"name":"0,1 V 至 10 V","range":"0,5 Hz 至 10 Hz","cmc":"0,001 %"},{"name":"0,1 V 至 10 V","range":"10 Hz 至 10 MHz","cmc":"0,001 %"},{"name":"10 V 至 750 V","range":"10 Hz 至 10 MHz","cmc":"0,01 %"},{"name":"0,1 V 至 10 V","range":"10 MHz 至 20 MHz","cmc":"0,001 %"}],"parameters_cs":[{"name":"0,1 V až 10 V","range":"0,5 Hz až 10 Hz","cmc":"0,001 %"},{"name":"0,1 V až 10 V","range":"10 Hz až 10 MHz","cmc":"0,001 %"},{"name":"10 V až 750 V","range":"10 Hz až 10 MHz","cmc":"0,01 %"},{"name":"0,1 V až 10 V","range":"10 MHz až 20 MHz","cmc":"0,001 %"}],"technique":"Pomiar bezpośredni licznikiem wzorcowym","technique_en":"Direct measurement with a standard counter","technique_zh":"用标准计数器直接测量","technique_cs":"Přímé měření etalonovým čítačem","techniques":["Pomiar bezpośredni licznikiem wzorcowym"],"techniques_en":["Direct measurement with a standard counter"],"techniques_zh":["用标准计数器直接测量"],"techniques_cs":["Přímé měření etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\n0,1 V do 10 V od 0,5 Hz do 10 Hz CMC 0,001 %\n0,1 V do 10 V od 10 Hz do 10 MHz CMC 0,001 %\n10 V do 750 V od 10 Hz do 10 MHz CMC 0,01 %\n0,1 V do 10 V od 10 MHz do 20 MHz CMC 0,001 %\nPomiar bezpośredni licznikiem wzorcowym","reference":"KP - 12","norm_bases":["KP - 12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / źródła napięcia przemiennego Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni licznikiem wzorcowym 0,1 V do 10 V od 0,5 Hz do 10 Hz CMC 0,001 % 0,1 V do 10 V od 10 Hz do 10 MHz CMC 0,001 % 10 V do 750 V od 10 Hz do 10 MHz CMC 0,01 % 0,1 V do 10 V od 10 MHz do 20 MHz CMC 0,001 % Frekvence / Zdroje střídavého napětí Kalibrace – veličiny času a frekvence Přímé měření etalonovým čítačem 0,1 V až 10 V 0,5 Hz až 10 Hz CMC 0,001 % 0,1 V až 10 V 10 Hz až 10 MHz CMC 0,001 % 10 V až 750 V 10 Hz až 10 MHz CMC 0,01 % 0,1 V až 10 V 10 MHz až 20 MHz CMC 0,001 % KP - 12 Czestotliwosc / zrodla napiecia przemiennego Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni licznikiem wzorcowym 0,1 V do 10 V od 0,5 Hz do 10 Hz CMC 0,001 % 0,1 V do 10 V od 10 Hz do 10 MHz CMC 0,001 % 10 V do 750 V od 10 Hz do 10 MHz CMC 0,01 % 0,1 V do 10 V od 10 MHz do 20 MHz CMC 0,001 % Frekvence / Zdroje stridaveho napeti Kalibrace – veliciny casu a frekvence Prime mereni etalonovym citacem 0,1 V az 10 V 0,5 Hz az 10 Hz CMC 0,001 % 0,1 V az 10 V 10 Hz az 10 MHz CMC 0,001 % 10 V az 750 V 10 Hz az 10 MHz CMC 0,01 % 0,1 V az 10 V 10 MHz az 20 MHz CMC 0,001 % KP - 12","search_en":"Frequency / AC voltage sources Calibration – time and frequency quantities Direct measurement with a standard counter 0,1 V to 10 V 0,5 Hz to 10 Hz CMC 0,001 % 0,1 V to 10 V 10 Hz to 10 MHz CMC 0,001 % 10 V to 750 V 10 Hz to 10 MHz CMC 0,01 % 0,1 V to 10 V 10 MHz to 20 MHz CMC 0,001 % KP - 12","search_zh":"频率 / 交流电压源 校准 – 时间和频率量 用标准计数器直接测量 0,1 V 至 10 V 0,5 Hz 至 10 Hz CMC 0,001 % 0,1 V 至 10 V 10 Hz 至 10 MHz CMC 0,001 % 10 V 至 750 V 10 Hz 至 10 MHz CMC 0,01 % 0,1 V 至 10 V 10 MHz 至 20 MHz CMC 0,001 % KP - 12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"32eca10e25e69b4365cdee5c","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / źródła prądu przemiennego","test_object_en":"Frequency / AC current sources","test_object_zh":"频率 / 交流电流源","test_object_cs":"Frekvence / Zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"0,05 A do 90 A","range":"od 20 Hz do 1 kHz","cmc":"0,01 %"}],"parameters_en":[{"name":"0,05 A to 90 A","range":"20 Hz to 1 kHz","cmc":"0,01 %"}],"parameters_zh":[{"name":"0,05 A 至 90 A","range":"20 Hz 至 1 kHz","cmc":"0,01 %"}],"parameters_cs":[{"name":"0,05 A až 90 A","range":"20 Hz až 1 kHz","cmc":"0,01 %"}],"technique":"Pomiar bezpośredni watomierzem wzorcowym","technique_en":"Direct measurement with a standard wattmeter","technique_zh":"用标准功率表直接测量","technique_cs":"Přímé měření etalonovým wattmetrem","techniques":["Pomiar bezpośredni watomierzem wzorcowym"],"techniques_en":["Direct measurement with a standard wattmeter"],"techniques_zh":["用标准功率表直接测量"],"techniques_cs":["Přímé měření etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\n0,05 A do 90 A od 20 Hz do 1 kHz CMC 0,01 %\nPomiar bezpośredni watomierzem wzorcowym","reference":"KP - 12","norm_bases":["KP - 12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / źródła prądu przemiennego Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni watomierzem wzorcowym 0,05 A do 90 A od 20 Hz do 1 kHz CMC 0,01 % Frekvence / Zdroje střídavého proudu Kalibrace – veličiny času a frekvence Přímé měření etalonovým wattmetrem 0,05 A až 90 A 20 Hz až 1 kHz CMC 0,01 % KP - 12 Czestotliwosc / zrodla pradu przemiennego Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni watomierzem wzorcowym 0,05 A do 90 A od 20 Hz do 1 kHz CMC 0,01 % Frekvence / Zdroje stridaveho proudu Kalibrace – veliciny casu a frekvence Prime mereni etalonovym wattmetrem 0,05 A az 90 A 20 Hz az 1 kHz CMC 0,01 % KP - 12","search_en":"Frequency / AC current sources Calibration – time and frequency quantities Direct measurement with a standard wattmeter 0,05 A to 90 A 20 Hz to 1 kHz CMC 0,01 % KP - 12","search_zh":"频率 / 交流电流源 校准 – 时间和频率量 用标准功率表直接测量 0,05 A 至 90 A 20 Hz 至 1 kHz CMC 0,01 % KP - 12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a5c99110c2e816f2fc0089e2","lab_id":"6ade8b2bff06824761708100","country":"CZ","accr_number":"2255","accr_body":"ČIA","row_label":"2","test_object":"Przedział czasu / kalibratory mierników do badań instalacji elektrycznych","test_object_en":"Time interval / Calibrators of inspection instruments","test_object_zh":"时间间隔 / 电气安装检测仪校准器","test_object_cs":"Časový interval / Kalibrátory revizních přístrojů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"0,1 V do 10 V","range":"od 1 ms do 5 s","cmc":"0,001 %"}],"parameters_en":[{"name":"0,1 V to 10 V","range":"1 ms to 5 s","cmc":"0,001 %"}],"parameters_zh":[{"name":"0,1 V 至 10 V","range":"1 ms 至 5 s","cmc":"0,001 %"}],"parameters_cs":[{"name":"0,1 V až 10 V","range":"1 ms až 5 s","cmc":"0,001 %"}],"technique":"Pomiar bezpośredni licznikiem wzorcowym","technique_en":"Direct measurement with a standard counter","technique_zh":"用标准计数器直接测量","technique_cs":"Přímé měření etalonovým čítačem","techniques":["Pomiar bezpośredni licznikiem wzorcowym"],"techniques_en":["Direct measurement with a standard counter"],"techniques_zh":["用标准计数器直接测量"],"techniques_cs":["Přímé měření etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\n0,1 V do 10 V od 1 ms do 5 s CMC 0,001 %\nPomiar bezpośredni licznikiem wzorcowym","reference":"KP - 12","norm_bases":["KP - 12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / kalibratory mierników do badań instalacji elektrycznych Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni licznikiem wzorcowym 0,1 V do 10 V od 1 ms do 5 s CMC 0,001 % Časový interval / Kalibrátory revizních přístrojů Kalibrace – veličiny času a frekvence Přímé měření etalonovým čítačem 0,1 V až 10 V 1 ms až 5 s CMC 0,001 % KP - 12 Przedzial czasu / kalibratory miernikow do badan instalacji elektrycznych Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni licznikiem wzorcowym 0,1 V do 10 V od 1 ms do 5 s CMC 0,001 % Casovy interval / Kalibratory reviznich pristroju Kalibrace – veliciny casu a frekvence Prime mereni etalonovym citacem 0,1 V az 10 V 1 ms az 5 s CMC 0,001 % KP - 12","search_en":"Time interval / Calibrators of inspection instruments Calibration – time and frequency quantities Direct measurement with a standard counter 0,1 V to 10 V 1 ms to 5 s CMC 0,001 % KP - 12","search_zh":"时间间隔 / 电气安装检测仪校准器 校准 – 时间和频率量 用标准计数器直接测量 0,1 V 至 10 V 1 ms 至 5 s CMC 0,001 % KP - 12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}